Loading...
HomeMy WebLinkAboutPermit D13-242 - SOUTHCENTER COMMUNITY BAPTIST - TENANT IMPROVEMENTSOUTHCENTER COMM BAPTIST CHURCH 14742 MACADAM RD S EXPIRED 01/27/14 D13-242 City oiltukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 7661600211 Address: 14742 MACADAM RD S TUKW Suite No: Project Name: SOUTHCENTER COMMUNITY BAPTIST CHURCH Permit Number: D13-242 Issue Date: 07/30/2013 Permit Expires On: 01/26/2014 Owner: Name: TUKWILA BAPTIST CHURCH Address: 14742 MACADAM RD S , TUKWILA WA 98188 Contact Person: Name: SCOTT CLEMENTS Address: 14742 MACADAM RD S , TUKWILA WA 98168 Phone: 206-228-1315 Contractor: Name: OWNER AFFIDAVIT - SCOTT CLEMENTS Phone: Address: Contractor License No: Expiration Date: Lender: Name: N/A < $5,000.00 Address: , DESCRIPTION OF WORK: REPLACING SHINGLES ON ONE OF OUR BUILDINGS, FELLOWSHIP HALL. Value of Construction: $3,355.45 Fees Collected: $386.80 Type of Fire Protection: International Building Code Edition: 2012 Type of Construction: V -B Occupancy per IBC: 0005 Electrical Service Provided by: SEATTLE CITY LIGHT **continued on next page** doc: IBC -7/10 D13-242 Printed: 07-30-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N Start Time: Volumes: Cut 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: -7- so -1'5 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this perm't does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the perforiance of work. I am authgrjzed t sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: C.(e 0-7 e n4S Date: 7— O This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D13-242 Printed: 07-30-2013 this requirement. • • 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate shall be provided to the building inspector. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D13-242 Printed: 07-30-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. 'tot3—may Project No. Date Application Accepted: ( 0 ''3 Date Application Expires: �� t(2.)—(21 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION U M King Co Assessor's Tax No.: 166160 —02 Gil' Site Address: I �' 12. eta AJ"t F p . S S. �J�W; IQ Suite Number: Floor: Tenant Name: New Tenant: ❑ Yes El „No 5o0Ceh (e,r CO /OM a,1 i Aet p °�i s t CL vrcL PROPERTY OWNER Name: S0tlt11Ce,i4er COM/4W;4 Lvgli.aaea Address:/ 7q met, getuen / L J . City: , (Q.,, I I ck State: W A Zip: q Si G b' CONTACT PERSON — person receiving all project communication Name: 5 co -1-+ C (e!t1 e n fS Address: City: State: Zip: Phone:a0 6..2.g-f3i) Fax: Email: S (.0-1-41 zo c:eCt m c. ct 0-. (AL T GENERAL CONTRACTOR INFORMATION Company Name: Address: Company Name: Address: Architect Name: City: State: Zip: Phone: Fax: Phone: Fax: Contr Reg No.: Email: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh ARCHITECT OF RECORD Name: Address: Company Name: Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Address: Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 335 S• 5 Existing Building Valuation: $ 7(7, vv !] Describe the.scope of work (please provide detailed information): P10-Cti 5h149ke an crnsi, of ocC lbk:dcfi',0 )" e kows1-.lto I')c111. QUI le{ A) (c i 4ctln S c+ 1ri4clsZ �, Mee Ivcj roor c�.c�cQ c) o 60TH, ro0"S.. Gtje c u.t 042I -f(st. work o seIWi sv f (firtcsz. of5 � iLor ct ciisOsme d/II�' . f%l>o, r >�+aal IV s5 a .4-( Uc.Ot)-i J2► Gt �2 t' I �'��'C/J . rw A �'t Of . (,) 11c1 ,05 — our Icc+ .4- Ccrck Ir > f ce f?Gt- C -306,poo ex - Will there be new rack storage? ElYes .. No If yes, a separate permit and plan submittal will be required. `� al u. It CtQ>Cie I�'�r for it -rote de -to i 1 Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC - Type of Occupancy per IBC l' Floor 5.-I la rr y 3" - 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 T APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR LITHOI , D T:11 Signature: Car Date: Print Name: S COt T C (e tr'? e 0 T 5 Day Telephone: ?-0(> - Z 28 ( 3 Mailing Address: I LI `- MCCGCJ` CA "`''G . 5 tac-v[ lG Luci6 (6 y 3-AriS, Ji H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-11 docx Revised: August 2011 bh City State Zip Page 4 of 4 II • CCity of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 7661600211 Permit Number: D13-242 Address: 14742 MACADAM RD S TUKW Status: PENDING Suite No: Applied Date: 07/18/2013 Applicant: SOUTHCENTER COMMUNITY BAPTIST CHURCH Issue Date: Receipt No.: R13-02172 Initials: WER User ID: 1655 Payment Amount: $386.80 Payment Date: 07/18/2013 02:55 PM Balance: $0.00 Payee: SCOTT CLEMENTS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 03577C ACCOUNT ITEM LIST: Description 386.80 Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $386.80 231.70 150.60 4.50 a o e Ana Printed: 07-18-2013 INSPECTION RECORD Retain a copy with permit 03-242 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:_ SGS i an `..S f Type of Inspection: li ; .(a - k. �F Ai Al__ Addre s: i-I��2 AAA A. -6,&M Date Called: Special Instructions: Date Wanted: m. i — Z/' !-4 Cpm Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 40 M (JS( tt Ate .1 a, riot -) r A -POC r du c , ^ S 7t-±-1(if-7704i -,`Ai p f' 0 E Ti i; r eiU ^. F AL v Insp ctor: J� r Date: Z�—.14 . Prior to n REINSPECTION FEE REQUIRE, next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Callao schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING. DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 le, (206) 431-3670 Permit Inspection Request Line (206) 431-2451 613 -i02 - Project: GONiT t4 i�i 2-C►_�v'1dV\. B 6 Type of Inspection: P ►s 4 P Q f- (2.. 20o r Address: "'II N 2- m AO M %>rvI R.0 Date Called: 51 Special Instructions: Date Wanted: 7 _ 3 1.1 3 (arrj:, p.m. Requester: Phone No: �.OG—ZZEg—I37S w `-Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: 1 SCN 1i'5.C.g1 : N- Q4 i ta'\.) N oT E:. i.o-1/4"..)o-.i Rev - WA e-1 i1��5"-f'_ / (\4 SVD Pe 9,.c�tt vee i 5 -Core/ 1,4,4t5.1e..4. . w inspe to l— n REINSPECTION FEE REQUI ED. Prior to next Inspection, fee must be-} d a 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date. _ z Southcenter Community Baptist Church 14722 MacAdam Rs S, Tukwila WA 98168 Cell 206-228-1315 Project Manager — Pastor Scott Clements FILE COPY We are replacing the shingles on one of our three buildings, "Fellowship Hall." This building is used for multipurpose. It has a kitchen, meeting room two bathrooms and a furnace room. The building is approximately 2365 square feet. 650 Square feet is a flat torchdown (labeld "A" on roof plan), with the remaining 1,750 as shingles. We will removes the current two layers of shingles, dispose of then through Evergreen Shingle Recycling in Woodenville and replace with "Owens Corning TruDuration Shingles." The single layer torchdown will be covered with an emulsion product — AP 302 Fibered Asphalt Emulsion. We will do all of the labor ourselves. Price sheet, material list and roofing manufacturer's specs are attached. The emulsion prodect is being donated by a church member who works for a Vancouver WA Roofing Company. We estimate 10 gallons, with the "gift in kind" worth about $160. /013 321Z REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 9 2013 • City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 18201.3 PERMIT CENTER SCBC FELLOWSHIP HALL Allied Building Products 1 "Owens Corning" TruDuration Shingles 63 Buddies $1,655.85 2 Starter Shingles. $73.00 3 Ridge $103.30 4 Ridge Vent $191.00 5 Felt 30Lb $353.40 6 Staples 3/8" $6.70 7 Coil Nails 1 1/4" $62.70 8 Valley Metal $134.50 $2,580.45 Roof Top Delivery $75.00 Recycle old shingles Evergreen shingle Recycling 6405 233rd PI SE Woodinville, WA 98072 425-482-0266 $700.00 N 16' 3" 14' 9" 54' 10" 13' 11" 9' 11" A N W r-1 N./ Shingles - 1950 Sq Ft Felt 2400 Sq Ft Ridge - 80 Ft 26' 2" ROOF PLAN "SCBC FELLOWSHIP HALL" PHOTO REPORT : Fellowship Hall PHOTO REPORT : Fellowship Hall PHOTO REPORT : Fellowship Hall PHOTO REPORT : Fellowship Hall FILE COPY Permit No. A/war COMPLIANCE: Exceeds performance requirements of ASTM D 1227, TYPE II, Class I. UL CLASS A RATED File #R11333. MIAMI-DADE APPROVED. ASBESTOS FREE. California products meet Los Angeles A.P.C.D. (Rule #102). DESCRIPTION: APOC® 302 Fibered Asphalt Emulsion is a UL Rated, fiber reinforced, professional grade product for coating built-up mineral surfaced, metal, concrete, corrugated and other roof surfaces. It is also great for use in polyester roofing systems. APOCe 302 has excellent weathering qualities and is non-flammable, odorless and bonds to damp or dry surfaces. It can also be used for damp -proofing above or below grade foundation walls, sealing masonry surfaces and retaining walls and as an anti -corrosive wood, metal, and pipe coating. Finally, APOC® 302 contains no solvents so it will not deteriorate or harm insulation or styrofoam boards and is easy to use and clean up. DO NOT ALLOW STORED PRODUCT TO FREEZE. PREPARATION: All surfaces must be clean, have proper drainage and be free of surface rust, dust and any other foreign matter. Roof surface may be damp (from morning dew), however surfaces may not be saturated with water. Brush clean all cracks, holes, and damaged or rusted areas with a wire brush. Repair using APOC White Roof Patch and Glass or Polyester Fabric. DO NOT HEAT OR THIN. DO NOT APPLY IF RAIN IS EXPECTED WITHIN 36 HOURS. APPLICATION: For exterior use only. Protective clothing and eyewear should be used during application of this product. Always apply on a clear, warm sunny day. Apply in morning hours to allow maximum cure time. Application should be completed a minimum of 4 hours prior to sunset. Temperatures must be above 55°F (for 24 hours) and rising, but not above 110•F. Apply using professional airless sprayer, brush or 1/2" to 3/4" nap roller. See system specifications for coverage rates. Cure times vary depending on coverage rates, humidity, temperature and texture of surface. Allow a minimum of 4 hours between coats. DO NOT APPLY TO DRIVEWAY SURFACES. PRECAUTIONS: Do not store at temperatures below 50°F. When transporting this product, ensure that lid is tight and pail secure and upright. Do not allow pail to tumble as this may cause lid to loosen and leakage to occur. Do not transport on passenger seats or inside the passenger compartment of any vehicle. Store product in the cargo area of vehicle, and secure over protective cloths to prevent damage due to accidental spills. Do not store at temperatures above 110° F. This manufacturer also disclaims liability for flat surface application where poor drainage or moisture may prevail. Do not reuse empty containers. Do not use in ontainer when not in use. / PVED s 9R CODE COIStM" APPROVED 'JUL 2 9 2013 City of Tukwila BUILDING DIVISION ter and soap. RECEIVED CITY OF TUKWILA JUL 182013 PERMIT CENTER bt14Z 02008 Gardner Asphalt Corporation Manufactured by / Fabricado por: Gardner Asphalt Corporation P.O. Box 5449, Tampa, FL 33675 See MSDS for more info MIAMIDADE COUNTY �.1:r0,�AM on EA* Fin Ewa,.."°"°,.,° UP, FOR USE IN CLASS A, B, OR C ROOFING SYSTEMS AP 302 FIBERED ASPHALT EMULSION Data Sheet TYPICAL PHYSICAL & PERFORMANCE CHARACTERISTICS Weight Per Gallon 8.5 lbs. Residue by Evaporation' 45% Adhesion to Polyurethane Foam Excellent Consistency Brush Skin Time (50% Relative Humidity, 70°F) 4-8 hours Full Cure (50% Relative Humidity, 70°F) 24-48 hours Application Temperatures 55° - 110°F Clean-up Tools Warm water, soap 'Note: Percentage may vary + or - 3% Approx. Shipping Weights: (Note: All approx. weights include container.) 5 gallons (18.9L) 45 lbs. 55 drums (208.2L) 510 lbs. 275 gallon tote (1,039.5L) 2,450 lbs. CAUTION!: HARMFUL OR FATAL IF SWALLOWED. EYE, SKIN AND RESPIRATORY IRRITANT. Contains petroleum based products. Keep away from heat, sparks and open flame. In case of contact with eyes, flush with large amounts of room temperature water for 15 minutes. Persons with skin or respiratory sensitivity should not use product without sufficient protection. Avoid prolonged breathing of vapor or spray mist. (NIOSH/MSHA TC 23C or equivalent). Use only with adequate ventilation. In case of irregular or stopped breathing, administer oxygen and/or give artificial respiration. Get medical attention, immediately. Contact with skin should be followed by washing with soap and water. If swallowed, do not Induce vomiting. Call physician immediately. FOR EXTERIOR USE ONLY Use with adequate Ventilation Keep Out of Reach of Children VOCNOS - Less than 1.0 grams per liter CALIF. PROP. 65 • CHEMICAL WARNING (CALIFORNIA HEALTH AND SAFETY CODE #25249.5 ET SEQ). WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects or reproductive harm. Use proper protection and adequate ventilation, when using product. WARRANTY AND DISCLAIMER: To the best of our knowledge, the technical data contained herein is true and accurate at the date of issuance and is subject to change without prior notice. User must contact APOC to verify correctness before specifying or ordering. No guarantee of accuracy is given or implied. Liability, if any, is limited to replacement of product unless installed by an approved contractor in accordance with APOC warranty procedures and program. For limited warranty and disclaimer information, visit our website at: www.apoc.com/productwarrantyinfo. *f« MADE Gardner Asphalt Corporation • P.O. Box 5449 • Tampa, Florida 33675-5449 Z; WA! Phone: (813) 248-2101 • Fax (813) 248-6768 • www.apoc.com K-013 Based m )t10 Coacaa@tallig 09= egad 40�v t,ttxa outpialtDdosigg ?7i itld.' It tman 5 BaCiaeGrOSI ftmlaa cuxia j (t}93 COGGIDl GTR3larri0-O IglaRRIEAM 0X4 YUlgi tYiatSi rAICa?? OffailVgMeiltibl --- -m ea; agfaaa)2d foulzwoha dlbwOroatGall Roofing Brand C 'Ai:igiV @VAR® B@ con keit) shingles Similar roofing Owens reduce reflect transferred needed tba t i Mie -OR energy-efficient products Corning Yoff flObP lB Ovide ENERGY energy energy, home's tokeept geographic -Boo-GET-PINK® Product ROO appliances J to energy-saving srmegboxi installed decreasing interior—and comfortable. location are cir Actual individual the TOO home, qualities. shingles properly. amount amount savings building -88.8-STAR-YEAS Attributes Length fl1164110200 MO MPH TI©lteuti Vim PROtection'' Non -Prorated doBP These of Owed conditioning based characteristics. eati information. Atm ocilizfem DEMI Mairicar Period NO S2aoxt§ efftalaDA Product Non® Duration® Specifications aloe O gto Shingles 91316mttogle' Exposure Shingles Square aa Bundles IA/ Square Coverage Square 98.4 abn Applicable AEU E 9 08, Standards alma AI ® aTKI Codes MIA 0 Gil DEM atm IF n MN DM GJ3iND99 CaiaaPeg Wad Md °o ChaGJ MN D W10, lip® 1 CEJ 1 accurately photo. ary accurately hou judge notice Tru Bond eproduce lag Aiglh grog propne ary k photographs pitch of Roofing &G c4ottOKOm DEA° amokralnOwzoil3024 CrQlithCO(to lAci eemi a Waal Ci l0 m Un'b- t-��p Q. cd �o lI &O fin. clew ® C ss a sf ezta eSIflbj�cMofta(sjrm w�eI/Mr:ao tleflOa Cr your color professional oteetion shingle oo ing contractor weathering -grade Applicable allowed Roofing Technolog Portland 7836 654 independent ofectron blended shingle -to -shingle Roofing d foRmv ea7 acuo . pBil D5Slighting,A5Ilshingleadaip0B3 iVCadgm sJsroofingdisplay 07 shinglestie•Q-iebet terti.€fjike I f0 � roof prior to Dorfinal E t N js toga. MiteMbEi3 r•7rrtaaGefto Rroerre eg2031B cif avow Cj pending rotection Roofing 6G ILBA co @a egath502it availability S'aTETE, 11:-L Your home is your sanctuary. It's the place where you want to feel the most comfortable. Safe. Protected. But no matter how much you love your house, it seems the work is never completely done. And if purchasing a new roof is on your to-do list, it may seem like a daunting task—especially if your roof is already damaged or leaking. Since a roof plays such an important role in protecting you and your family from the elements, you realize that you can't let the damage get out of hand. Don't worry, we know that a roof replacement project is a big, important decision. You can feel confident about choosing our roofing products—Owens Corning has been a recognized leader in the building industry for over 70 years. In fact, we're America's #1 roofing brand.** Not only can we help you choose the right shingle and roofing system components, we can also help you select the right contractor for the job. An Owens CorningTM Roofing Preferred Contractor. ov Together we can make this a positive experience—an opportunity, really. This is your chance to choose a roof that not only has outstanding performance, but also has exceptional beauty. So for years to come, you'll feel great every time you pull in the driveway. Safe. Protected. Home. WANT 70 TURN UP TKIE COLOR E ON YOMG AROO oOlF? Update it with our TruDefinition'R' Duration',' Designer Colors Collection Shingles. They offer the same exceptional performance—in seven unique colors you won't find elsewhere. To see how they can transform the look of your home, just ask your contractor or visit www.roofing.owenscorning.com. Coppert Merlott Pacific INNOVATIONS FOR LIVING' T DefinitionLR' D D L J Okr HNG with SureNail'R' Tech VIEWED FOR Co ologPP°V !UtIL 2 9_201 Oily of T€ wla thL NGL M 1 1 Canyont Storm Cloudt Before Want to know more about Owens Corning' products or find an Owens Corning' Roofing Preferred Contractor in your area? It's easy to reach us: F -800-G ET-PONK'R, I www.roofing.owenscorning.com KESING INNOVATIONS FOR LIVING' OWENS CORNING ROOFING AND ASPHALT, LLC ONE OWENS CORNING PARKWAY TOLEDO, OHIO, USA 43659 1-800-G ET -PINK® www.roofing.owenscorning.com Pub. No. 10014053-A. Printed in U.S.A. May 2012 THE PINK PANTHER'" & ©1964-2012 Metro -Goldwyn -Mayer Studios Inc. All Rights Reserved. The color PINK is a registered trademark of Owens Corning.©20120wensCorning All Rights Reserved. trnn,,,+nn nonvor P„r+loud UN TrolDefinition® -2U D "--1-01M®SG OHNG_HS with SureNail® Technology TruDefinition Duration® Shingles are specially formulated to provide greater contrast and dimension to any roof. Through the use of multiple granule colors and shadowing, TruDefinition Duration Shingles offer a truly unique and dramatic effect. This exclusive combination of color and depth is what makes TruDefinition Duration Shingles like no other. TruDefinition Duration Shingles are available in popular colors with bold, lively contrast and complementing shadow lines fo"r greater - dimension. They feature a Limited Lifetime Warranty,`/** 130 -MPH Wind Resistance Limited Warranty' and an Algae Resistance Limited Warranty.* Beyond the outstanding curb appeal and impressive warranty coverage, they also come with the advanced performance of patented SureNail® Technology. �� / The SureNail® Difference— ® - �A. technological breakthrough aao°�Naif Technology in roofing. The innovative features of Owens Corningrm TruDefinition Duration Shingles with patented SureNail Technology offer the following: Breakthrough Design. Featuring a tough, woven engineered reinforcing fabric to deliver consistent fastening during installation. Triple Layer Protectionro A unique "triple layer" of reinforcement occurs when the fabric overlays the common bond of the shingle laminate layers that offers excellent fastener holding power. Superior Adhesion. Our enhanced Tru -Bond®$ sealant grips tightly to the engineered fabric nailing strip on the shingle below. Excellent Adhesive Power. Specially formulated, wide adhesive bands help keep shingle layers laminated together. Exceptional Wind Resistance. The industry's first asphalt roofing shingle engineered to deliver 130 -MPH* wind warranty performance with only 4 nails. 33% fewer nails are required for maximum warranty protection; which can mean fewer deck penetrations. SureNail® Reinforcing Woven Fabric Nailing Area Excellent Adhesive Power Enhanced Tru -Bond® Sealant Triple Layer Protections"'tt OOLORS LABLE ALL SERVIOE EAS—see uurep below Desert Tant Brownwoodt SQuarry Grayt Sierra Grayt Teakt '57.7.1`;-.:.' t T' °✓tnY } _ ` Pavy f t :i" F.v -sem 3• f a u Zitl 1Q.ot .' ` ,, x f Y y :j N w' Y.y'> 'ir.<„ 4 yt r �' er v.teaa =+r dit2.L MA-" y� '. 4 2 XX� r Shasta Whitet Driftwoodt Harbor Bluet Onyx Blackt Chateau Greent Estate Grayt ADDITIONAL OOOLORS GJb�[l LABLE SERVIOE AREA—see Otiiep below Ambert / Terra Cottat Not available in Service Area 13. Not available in Service Area 13. COLOR AVAOLLAE.,OLOTY MAP 12/2/2013 City of Tukwila Department of Community Development SCOTT CLEMENTS 14742 MACADAM RD S TUKWILA, WA 98168 RE: Permit No. D13-242 SOUTHCENTER COMMUNITY BAPTIST 14742 MACADAM RD S Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/27/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/27/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, J:nnif Marshall P mit I echnician File No: D13-242 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 �yzTu• t1' of Ci kwila • September 18, 2013 Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Scott Clements Tukwila Baptist Church 14742 Macadam Rd S Tukwila, WA 98168 RE: Refund of Overpayment for Application Number D13-242 Dear Mr. Clements, Due to an error in the computer program settings the permit fee calculations were incorrect. This error resulted in an over payment of fees for the building permit which in turn resulted in an overpayment in the plan review fee also. Enclosed is a check in the amount of $103.95 (one hundred three dollars and ninety- five cents). Sincerely, Bill Rambo Permit Technician File: Permit No. D13-242 End: Check No. 364307 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • PERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-242 DATE: 07-18-13 PROJECT NAME: SOUTHCENTER COMMUNITY BAPTIST CHURCH SITE ADDRESS: 14742 MACADAM RD S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 4ullding Division Public Works n "7-d-1-1-5 Fire Prevention II Structural Planning Division Permit Coordinator U DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 07-23-13 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route ip Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: DUE DATE: 08-20-13 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 • CITY OF TUKWILA Department of Community Development 6300 Southcenter Boulevard, Tukwila, WA 98188 Telephone: (206) 431-3670 FAX (206) 431-3665 E-mail: tukplanPci.tukwila.wa.us Permit Center/Building Division 206 431-3670 Public Works Department 206 433-0179 Planning Division 206 431-3670 AFFIDAVIT IN LIEU OF CONTRACTOR REGISTRATION STATE OF WASHINGTON) ) ss. COUNTY OF KING ) Sco-4 plc./A- , states as follows: PERMIT NO: ) 3 `; 7 ,R [please print name] 1. I have made application for a permit from the City of Tukwila, Washington. 2. I understand that state law requires that all building construction contractors be registered with the State of Washington. The exceptions to this requirement are stated under Section 18.27.090 of the Revised Code of Washington, a copy of which is printed on the reverse side of this Affidavit. I have read or am familiar with RCW 18.27.090. 3. I understand that prior to issuance of a permit for work which is to be done by any contractor, the City of Tukwila must verify either that the contractor is registered by the State of Washington, or that one of the exemptions stated under RCW 18.27.090 applies. 4. In order to provide verification to the City of Tukwila of my compliance with this requirement, I hereby attest that after reading the exemptions from the registration requirement of RCW 18.27.090, I consider the work authorized under this permit to be exempt under number 1 j, and will therefore not be performed by a registered contractor. 5. I understand that the licensing provision of RCW 19.28.161 through 19.28.271 shall not apply to persons making electrical installations on their own property or to regularly employed employees working on the premises of their employer. The proposed electrical work is not for the construction of a new building for rent, sale or lease. I understand that I may be waiving certain rights that I might otherwise have under state law in a , decision to engage an unregistered contractor to perform constructi work. Owner/Owner's Agent* Signed and sworn to before me this day of c1 20J . Y PUBLIC in and for the State of Washington Residing at Name as commissioned: My commission expires: , County iftthifle 18.27.090 Exemptions. The registration provisions of this chapter do not apply to: 1. An authorized representative of the United States government, the state of Washington, or any incorporated city, town, county, township, irrigation district, reclamation district, or other municipal or political corporation or subdivision of this state; 2. Officers of a court when they are acting within the scope of their office; 3. Public utilities operating under the regulations of the utilities and transportation commission in construction, maintenance, or development work incidental to their own business; 4. Any construction, repair, or operation incidental to the discovering or producing of petroleum or gas, or the drilling, testing, abandoning, or other operation of any petroleum or gas well or any surface or underground mine or mineral deposit when performed by an owner or lessee; 5. The sale of any finished products, materials, or articles of merchandise that are not fabricated into and do not become a part of a structure under the common law of fixtures; 6. Any construction, alteration, improvement, or repair of personal property performed by the registered or legal owner, or by a mobile/manufactured home retail dealer or manufacturer licensed under chapter 46.70 RCW who shall warranty service and repairs under chapter 46.70 RCW; 7. Any construction, alteration, improvement, or repair carried on within the limits and boundaries of any site or reservation under the legal jurisdiction of the federal government; 8. Any person who only furnished materials, supplies, or equipment without fabricating them into, or consuming them in the performance of, the work of the contractor; 9. Any work or operation on one undertaking or project by one or more contracts, the aggregate contract price of which for labor and materials and all other items is less than five hundred dollars, such work or operations being considered as of a casual, minor, or inconsequential nature. The exemption prescribed in this subsection does not apply in any instance wherein the work or construction is only a part of a larger or major operation, whether undertaken by the same or a different contractor, or in which a division of the operation is made into contracts of amounts less than five hundred dollars for the purpose of evasion of this chapter or otherwise. The exemption prescribed in this subsection does not apply to a person who advertises or puts out any sign or card or other device which might indicate to the public that he or she is a contractor, or that he or she is qualified to engage in the business of contractor; 10. Any construction or operation incidental to the construction and repair of irrigation and drainage ditches of regularly constituted irrigation districts or reclamation districts; or to farming, dairying, agriculture, viticulture, horticulture, or stock or poultry raising; or to clearing or other work upon land in rural districts for fire prevention purposes; except when any of the above work is performed by a registered contractor; 11. An owner* who contracts for a project with a registered contractor, except that this exemption shall not deprive the owner of the protections of this chapter against registered and unregistered contractors. The exemption prescribed in this subsection does not apply to a person who performs the activities of a contractor for the purpose of leasing or selling improved property he or she has owned for less than twelve months; 12.* Any person working on his or her own property, whether occupied by him or her or not, and any person working on his or her personal residence, whether owned by him or her or not but this exemption shall not apply to any person who performs the activities of a contractor on his or her own property for the purpose of selling, demolishing, or leasing the property; 13. An owner* who performs maintenance, repair, and alteration work in or upon his or her own properties, or who uses his or her own employees to do such work; 14. A licensed architect or civil or professional engineer acting solely in his or her professional capacity, an electrician certified under the laws of the state of Washington, or a plumber certified under the laws of the state of Washington or licensed by a political subdivision of the state of Washington while operating within the boundaries of such political subdivision. The exemption provided in this subsection is applicable only when the person certified is operating within the scope of his or her certification; 15. Any person who engages in the activities herein regulated as an employee of a registered contractor with wages as his or her sole compensation or as an employee with wages as his or her sole compensation; 16. Contractors on highway projects who have been prequalified as required by RCW 47.28.070, with the department of transportation to perform highway construction, reconstruction, or maintenance work; 17. A mobile/manufactured home dealer or manufacturer who subcontracts the installation, set-up, or repair work to actively registered contractors. This exemption only applies to the installation, set-up, or repair of the mobile/manufactured homes that were manufactured or sold by the mobile/manufactured home dealer or manufacturer .04'; 18. An entity w to olds a valid"ble>rti;•ical contractor's license under chapter-; 9.28`RCW that employs a certified journeyman el'ectrican, a certified'resideritial specialty electrician, or'an electrical trainee meeting the requirements of chapter 19.28,RCW forperform plumbing work that is indidenfally,.directly, and?iiYiinediately appropriate to the,like-,,}}`p;liil}dreplacement of a household appliance or other small 1'iouseholdrutilization equipment that requires limited elecTricfiSW"er and limited waste and/or water connections. An electrical trainee must be supervised by a certified electrician while performing plumbing work. • Per Washington State Department of Labor and Industries lessee has been interpreted to be equivalent to owner for purposes of exemptions. oSie- i' A RATE PERMIT RQUIPRED FOR: Mechanical Ergiectrical tumbing geas Piping Cil'j of Tukwila EI,.I I_O>NG DIVISION 496J' N 88'4810" W FILE COPY Permit No._1)1S- ).34P Plan review approval is subject to errors and omissions, of construction documents does not authorize t`r ..t<wtion of any adopted code or ordinance. Receipt o approved Field iopy and conditions is awledged: By — cAibt Date: 7 _ C City Of Tukwila BUIL j jG DIVISION NNN L 1� LIGHT 5" 1 l' SITE FLAN 450.2' N- 88°36'40 W LEGAL DESCRIPTION: N 1/2 OF TRACT 12, SEATTLE LAND CO'S TO PLAT THEREOF RECORDED IN VOL. OF KING COUNTY, WASH. LYING EAST AREA 50,146 SF., 1.84 ACRES REVISIONS No changes shall be made to the scope of work Without prior approval of ukwila Building Division. l ! '' F : F ,'�;:GOrt, will require a new plan submittal may in;,'ude additional plan review fees. 1/16" = 1'-0" NORTH ` BOTTOM Oa 5 ACRE TRACTS ACCORDING 6 OF PLATS PG. 90 REC c'e/IE D.FOR CODE COMPLIANCE APPROVED JUL 2 9 2013 A -T City of Tukwila BUILDING DIVISION w 0 I m 1ci z OF SLOPE RECEIVED CITY OF TUKWILA JUL 182013 PERMIT CENTER b32 z B ROWELEIT PETERSON HAMMER ARCHITECTS PS 19624A -76TH AVE. W. LYNNWOOD, WA 98036 PH. 425) 7744701 FAX (425) 776.5177 BPHARCH.coM Southcenter Community Baptist Church 14742 Macadam Rd. S. Tukwila, WA 98168 No./Date Revision By Dote 5H Drown By SH Checked By Project Number File Number SITE PLAN Sheet Title Al Sheet Number