Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D13-260 - MAURICES - TENANT IMPROVEMENT
MAURICES 1071 SOUTHCENTER MALL D13-260 City oikukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 1071 SOUTHCENTER MALL TUKW Project Name: MAURICES Permit Number: M13-143 Issue Date: 09/17/2013 Permit Expires On: 03/16/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: TIM SCHENK Address: 1120 E 80 ST, SUITE 211 , BLOOMINGTON MN 55420 Email: TIMS@ELDERJONES.COM Contractor: Name: J E M CONSTRUCTION INC Address: 29506 8TH AVE S , ROY, WA 98580 Contractor License No: JEMCOI*033DD Phone: 952-345-6040 Phone: 253 843-2765 Expiration Date: 05/15/2015 DESCRIPTION OF WORK: TENANT IMPROVEMENT: REPLACE (1) ROOF TOP UNIT, MODIFY DUCTWORK, NEW DIFFUSERS, CONTROLS, NEW RESTROOM EXHAUST FAN, TRANSFER GRILLES. Value of Mechanical: $15,000.00 Fees Collected: $374.62 Type of Fire Protection: UNKNOWN International Mechanical Code Edition: 2012 Electrical Service Provided by: Permit Center Authorized Signature: / UV V6\/ I hereby certify that I have read and governing this work will be complie xam with Date: t� ned this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signatur� � Print Name:iylA/ i1-1LRAGE_ Date: a! 1 % r(r This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. J--. IRA!, A/411 11/111_1.41 Printers• 0Q-17-2(111 PERMIT CONDITIONS Permit No. M13-143 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***FIRE DEPARTMENT CONDITIONS*** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 11: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 12: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 13: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IMC -4/10 M13-143 Printed: 09-17-2013 7: All construction shall be done in conform with the approved plans and the requiremof the International Building Code or International Residential C International Mechanical Code, Washingt to Energy Code. 8: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 9: All rack storage requires a separate permit issued through the City of Tukwila Permit Center. Rack storage over 8 -feet in height shall be anchored or braced to prevent overturning or displacement during seismic events. The design and calculations for the anchorage or bracing shall be prepared by a registered professional engineer licensed in the State of Washington. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 12: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 13: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 14: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 15: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 16: ***FIRE DEPARTMENT CONDITIONS*** 17: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 18: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 19: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 20: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 21: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 22: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NEPA 10, 4-3, 4-4) 23: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 24: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle doc: IBC -7/10 D13-260 Printed: 09-17-2013 is engaged from inside the tenant space. (IFC pter 10) 25: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 26: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 27: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 28: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be less than 0.375 inch (9.5 mm). Signs larger than the minimum established in section 1011.5.1 of the International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (1FC 1011.5.1) 29: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1006.1, 1006.2, 1006.3) 30: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 31: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 32: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 33: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 34: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 35: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2328.(ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 36: Local U.L. central station supervision is required. (City Ordinance #2328) 37: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 38: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 39: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 40: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 41: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 42: Post address on storefront per approved Westfield standards. doc: IBC -7/10 D13-260 Printed: 09-17-2013 43: Contact The Tukwila Fire Prevention Burelo witness all required inspections and teststy Ordinances #2327 and #2328) 44: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 45: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IBC -7/10 D13-260 Printed: 09-17-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. ,C j- 20 G Project No. Date Application Accepted Date Application Expires: 1 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: Q?A V47 QOt Site Address: 1011 SdviIACE r€11. MALL Tenant Name: MAklR.tCES Suite Number: 4046 Floor: 1 PROPERTY OWNER Name: 4 Sft=traLO LLL Address: 633 SOV tNCC7.1 fE(L MA Ll. City: Se...4ace_ State: NA Zip:Q1st gg CONTACT PERSON — person receiving all project communication Name: -rim 5 C. 4 EPA< Address:IA. 1120 E•�0— sr. s4tTEill . City: 6worntritaa State: riff. Zip:55%12Q Phone: cis 2.1,4. 6040 Fax: ci 52.4554. 44,09 Email: T..; N►5 @ efalerl•OAeS• ca, .. GENERAL CONTRACTOR INFORMATION Company Name: T.6.1J_ Architect Namup.x.A 5. swir'1 utoci< Address:613G 5. SqnIgu(Ll (&o City: WesYtt�IC State: Q Zip:4��l Address: Email: ' por}lLV S Q.S�Y`Pift5110Ck. CO"... Email: $k rik e p :1 city cb.6c,,-• State: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: H:\Applications\Forns-Applications On Line\2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh New Tenant: ,l '' Yes ❑ ..No ARCHITECT OF RECORD Company Name: Su Sti10CK AItL1wvCS . 1n1 c_. - Architect Namup.x.A 5. swir'1 utoci< Address:613G 5. SqnIgu(Ll (&o City: WesYtt�IC State: Q Zip:4��l Phone: 6A, S,4S: cisco Fax: 4314 .Sys14sss- Email: ' por}lLV S Q.S�Y`Pift5110Ck. CO"... ENGINEER OF RECORD Company Name: pavc. T.FoKo rcomsapoY. Engineer Name: C RAtG M Ica Ai .. f 1143 t ER R0 _ Address: Silistitg Z50 €As,r aajzAD Sfl6& City: caLv na vt State: 013 Zip: y.5 IA S' Phone: 6 !`i •zz1. 661 Fax: 4 1,4 . Z..Q .466. Email: $k rik e p :1 city cb.6c,,-• LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: (41A . cput.- '44imAiL c-. Address: City: State: Zip: Page I of 4 BUILDING PERMIT INFORMATION 206-431-3670 Valuation of Project (contractor's bid price): $ **2-03.040, Existing Building Valuation: $ 24°1`4"b. '- Describe Describe the scope of work (please provide detailed information): Rentsoec, Ot /r exi smvt,- (LcrAlc. rehrwr sP9cc Ara, A Faln.r'ro,v dr' AK ADJAC 1 r :14A.rr sPacz -P3 vtEAr- A Kir .SPAck Flt. 4MA vagia n, Alew PAW ria,rs.CI eta nr6S Sr4a. Rxr atES sJ a=t!Y''.... l�i xN1LES, I,f1tAdori CrNISM65t . W'' GL J?Z(Cp(„ /14GWoin0.7 01013 o trri `S r $it td. N € t4 (fl' t 4PeAci L. C -c v , O t R asat s C c aA(,S tx I 1 s r r=/Nry . Will there be new rack storage? in Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Floor area of accessory dwelling: Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 10 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers ❑ Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ®, No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forns-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 15` FloorSVC{3 soc 3 - ' ( M 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Floor area of accessory dwelling: Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 10 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ® Sprinklers ❑ Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes ®, No If `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forns-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 • • PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER cOR /UTTHORRIIZED AGENT: Signature: y ' "' Date: Print Name: 1-1 M ScI.►En k- Day Telephone: qn .14C. . 6040 Mailing Address: ((20 E. 8a K' SITI er, S4I sE Z41, Qu)orn Irivant, N SY' ZQ City State Zip H:\Applications\Forma-Applications On Line \2011 Applications\Permit Application Revised - 8.9-11,docs Revised: August 2011 bh Page 4 of 4 • �J�.`N��A wq� City of Tukwila C�ti � � O 1908 • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.Rov RECEIPT Parcel No.: 9202470010 Permit Number: D13-260 Address: 1071 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 08/12/2013 Applicant: MAURICES Issue Date: Receipt No.: R13-02648 Initials: JEM User ID: 1165 Payment Amount: $2,366.10 Payment Date: 09/17/2013 11:15 AM Balance: $0.00 Payee: JEM CONSTRUCTION, INC. TRANSACTION LIST: Type Method Descriptio Amount Payment Check 12037 2,366.10 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 640.237.114 Total: $2,366.10 2,361.60 4.50 ,.',.,.. oe..ei.,+_na Printed: 09-17-2013 C"f Tukwila. Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us SET RECEIPT RECEIPT NO: R13-02342 Initials: WER Payment Date: 08/12/2013 User ID: 1655 Total Payment: 1,744.28 Payee: ELDER JONES SET ID: 081213 SET NAME: MAURICES SET TRANSACTIONS: Set Member Amount D13-2.60 EL13-0761 M13-143 TOTAL: 1_,535.04 134.32 74.92 1,535.04 TRANSACTION LIST: Type Method Description Amount Payment Check 65937 ACCOUNT ITEM LIST: Description TOTAL: 1,744.28 1,744.28 Account Code Current Pmts ELECTRICAL PLAN - NONRES PLAN CHECK - NONRES 000.345.832.00.0 134.32 000.345.830 1,609.96 TOTAL: 1,744.28 450 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION G, 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 bi -Z6,o Project: Matt, -es Type Inspection .�3�.1 a.A -rAJ -L Address: 1 0 -7 r s{ AitA-1( Date Called: Special Instructions: Date Wanted:' — ' r�� p.m. Requester: Phone No: Approved per applicable codes.0 Corrections required prior to approval. COMMENTS: Insptor: ( Date: (2 ! L n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 �i3-2$f1 Project: iirtzi//r�sGC,it"e-, Type of Inspection: �i� ---/ �i ; Address: /07/ .5 Y fr9 !I Date Called I--,ivitI Special Instructions: m Date Wanted; �'/f` kequester: Phone No: pproved per applicable codes. ['Corrections required prior to approval. OMMENTS: .-Altvi41p7 I %5kIl,..a5 - 4ep.".0%� J ? -'t,;V ( E/i-efr o4 1 %iN4/- ijfr If el 7 -?1) 44# /dye el — , d,/ c1 S kectoffr: Dat :/ /0 43 1 n R IN PECTION FEE RE UIRED. Prior to ex inspection. fee must be pa d,et 6300 Southcenter lvd., Suite 100.fCall to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 -2(® Proje t: C !aJrI CS Type of Inspection: lv . � 6,*t .46 FIA l Address: (oil s MA -MI Date Called: Special Instructions: - Date Wanted:r I 1---/ — ( 3 p.m. Requester: Phone No. — ¥43 ,/2) (S JApproved per applicable codes. Corrections required prior to approval. COMMENTS: kiefo FUrA lufe pt . Skek-i, � 'I0jr- 7 0k of :4 6 k e-` o( iv-6enA 0J r-,`/ P-ivtlet, - L klr, Al C.) MA elij - . 1.\ A &-(J / `l 4 C_A-'( r ,) /L„ S -5 . r c._,e -( 0 Iyfspector: 64 4-k Date:! t ,1 13 REINSPECTION FEE REQ\FJIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 3 1,3 -2.00 Project: . Project:, Type of Inspection: Type -� to -a46 Ad're�s�s: ? ( SC ( Date Called: Special Instructions: i I Date Wanted: t 3 p.m. Requester: Phone 2 3-2'7&.5 Approved per applicable codes. 0Corrections required prior to approval. COMMENTS: I Inspe Date: n REINSPECTION FEE RE4UIR[D:-Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Type of Inspection: Address: tb1l SC 1/11 r\ I-4— Date Called: Special Instructions: Date Wanted:m".` (t — t _ t -z, p.m. Requester: Phone No: ,253 -6 -e5 - Approved per applicable codes. Corrections required prior to approval. COMMENTS: ‘ca Le 0—R ! A Date: SPECTION FEE RE IRED. Prior to ext inspection. fee m st be at -6300 Southcenter lvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, -Tukwila. WA 98188 (206)431-3670 Permit Inspection Request Line (206) 431-2451 !tel 3- Z �O C Project:Type of Inspection: Address: 1 O —7 1 G YV‘ PA LC— Date Called: Instructions: Date Wanted: m.. .2,Special I D--C'j-Ip. Requester: Phone No: g 3 _ GO (J _' Sc? 2 t-( AApproved per applicable codes. El Corrections required prior to approval. 6 COMMENTS: Ins � tor: AAA -4 F' JCA. �(3. R NSPECTION FEE •EQUIRED. Prior tt next inspection, fee must be p d at 6300 SouthcentBlvd., Suite 100. Call to schedule reinspection. Da e: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit rV.) 1 - - c2cII e "7 C e PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 i Project: Sprinklers: Fire Alarm: Type of Inspection: c' Address: / n 7 J --- Suite #: ( • inn..) L G..-- Contact Person: Special Instructions: ... 1-""7,,,) Phone No.: .,Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Q ) c' ... 1-""7,,,) l I . 1.t4 ? — i�;r-' 0- L °K\ _ c . 2, 7 -- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: /1 f S %r Hrs.: f $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Word/Inspection Record Form.Doc 6/11/10 Zip: T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit T>-13 - z (o -t: 13 -S -Z35 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 714AveiZICes Type of Inspection: F/k —SP — Address: Suite#: I0?I SC Mki(( Contact Person: Special Instructions: I Ni cE Phone No.: , Approved per applicable codes. Corrections, required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: ) t f 'T' 0 S Pr) w(C.Q(.+. Pre -Fire: I Ni cE GQ S'S 4 Tae i-. pSSi a MS 9 ilh , N _cf,-o L --- n g- uM (rt 4% C;.44*-.-- < t din i -pct,. No4 aN S14cz) Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector' c.47*5-3 Date: ///7/13 Hrs.: 1 0 $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit D-13-ZGo° /3-S- 23S` PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Apt/ice( SC 41,41/ Type of Inspection: ire - Contact Person: Address: Suite #: /0 -7/ Special Instructions: - Phone No.: I Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: — (l ` 7' Gaeo - .‹f? he/ /Ai S41 AfrAM - s ✓.4- Aaa.k-. ev-,41.0( roi Coater/.,fir. 0/‘072,.4)44- ' .e - 6VZ in.7 1 - .fieed'r 74 vim' A.0~/ ee 44' s Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: I Occupancy Type: Inspecto: �, .7q3 Date: 164/x//3 Hrs.: -,443m.---/. $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: OtNPiCe-S Type of Inspection: S,,o� e"ooe Address: 4/fontact Suite #: I O%/ 56a f--4 celll_-e/. Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: 01< r ' 40erdl b S<e r�r� 7' /116 r /cr !lam p(Gzn 5 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits:. Occupancy Type: Inspector: S Date: /01/f / j Z Hrs.: 03-' $100.00 REINSPECTION FEE REQUIRED. You witl deceive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary LGT-SUM 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address SOUTHCENTER MALL Date 8/9/2-013 2800 SOUTHCENTER MALL, SPACE: 408 For Building Department Use FILE COPY SEATTLE, WA 98188 Applicant Name: SHREMSHOCK ENGINEERING INC Applicant Address: 6130 S. SUNBURY RD WESTERVILLE OH, 43081 Applicant Phone: 614-545-4550 Project Description ❑ Plans Included ✓ New Building ❑ Addition ❑ Alteration Lighting Compliance Path 0 Lighting Power Density Calculations Q Total Building Performance (If Total Building Performance then only LGT-CHK is required.) Interior Lighting Compliance Option 0 Building Area Method Q Space -by -space Method Interior Lighting System Description Briefly describe lighting system type and features. In the sales area, recessed fluorescent troffers and pendants provide general lighting, and track lighting highlights the sales shelving and racks. Four contactors controlled by two time clocks automatically control these lights and have manual override switches. In the nonsales and restroom areas, surface -mounted linear fluorescent fixtures provide general lighting and are controlled by occupancy sensors. Additions and Change of Space Use (C101.4.3 & C101.4.4) ❑ Addition area or Change of Space Use area complies with all applicable provisions as stand alone project ❑ Addition area or Change of Space Use area is combined with existing building lighting systems to demonstrate compliance with all applicable provisions Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Compliance Form. Document maximum allowed and proposed (including existing if applicable) lighting wattage of Addition or Change of Use scope. Provide applicable lighting controls per C405.2 and commissioning of lighting controls per C405.13. Alterations, Renovations and Repairs (C101.4.3.1) _o ❑ 60% or more of luminaires in space replaced Provide Building Area Method (LTG -INT -BLD) or Space -By -Space Method (LTG -INT -SPACE) Complia allowed and proposed (including existing) lighting wattage of project scope REVIEWED FOR c . ce �7�1►Rirelirr�u i' APPROVED ❑ Less than 60% of luminaires in space replaced Provide Space -by -space Method (LTG -INT -SPACE) Compliance Form. Document existing total watta (including existing) lighting wattage of project scope in spa d Pros 13 ❑ Lamp and/or ballast replacement within existing luminaires only — existing total interior building wattage of increased City of Tukwila ❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable manual lighting controls (C405.2.1), occupancy sensors (C405.2.2.2), daylight zone application controls (C405.2.3), and commissioning of lighting controls per C405.13 BUILDING DIVISIOI -ecifrt--- 405.2.2.3), ❑ New or moved lighting panel Provide all applicable lighting controls as noted for New Wiring, automatic time switch controls (C405.2.2.1), and commissioning of lighting controls per C405.13. ❑ Space is reconfigured - luminaires unchanged or moved only � Provide all applicable lighting controls as noted for New Wiring and commissioning of lighting controls per C405.13. �GE Q' PRO � j� ❑ No changes are being made to the interior lighting and space use not changed. �pF$ b 13 0 RECEIVED CITY OF TUKWILA AUG 1 2 2013 PERMIT CENTER 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary - Space -by -Space LTG -INT -SPACE 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address SOUTHCENTER MALL Date 8/9/2013 2800 SOUTHCENTER MALL, SPACE: 408 For Building Department Use SEATTLE, WA 98188 Applicant Name: SHREMSHOCK ENGINEERING INC Maximum Allowed Lighting Wattage Location (plan #, room #, or ALL) Space Type* Allowed Watts per ft2 Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) E-1: SALES Retail: Sales area 1.68 4083 6859 E-1: NONSALES Warehouse: Medium/bulky material 0.58 960 557 E-1: RESTROOM Restroom 0.98 50 49 E-1: SALES M/P - 3 -32W -T8 ELECTRONIC BALLAST 34 93 Atrium** Enter Height: E-1: SALES AA - 4-26W-GU24 8 Retail Display Allowance from LGT-INT-DISPLAY-,. ;..s,a,: '' 3360 * Select Table C405.5.2(2) category from drop down menu. ** For atriums, indicate height.Allowed wattage for first 40 feet is 0.03 W/ft. ht., above 40 feet is 0.02 W/ft. ht. Proposed Lighting Wattage Total Area Allowed Watts 5093 10825 Location (plan #, room #, or ALL) Fixture Description (Include exempt equipment per Note 3) Number of Fixtures Watts/ Fixture Watts Proposed E-1: SALES TRACK (EXERTION #13) 10 E-1: SALES G - RECESSED CAN LIGHT 2 -42 -PLT (EXERTION #13) 6 E-1: SALES M/P - 3 -32W -T8 ELECTRONIC BALLAST 34 93 3162 E-1: SALES AA - 4-26W-GU24 8 104 832 E-1: SALES BB - 1 -100W -E26 1 100 100 E-1: SALES CC - 3 -40W -G9 6 120 720 E-1: SALES H/L - 2-40W-BIAX ELECTRONIC BALLST 2 72 144 E-1: SALES Z - 1 -100W -E26 8 100 800 E-1: SALES G - RECESSED CAN LIGHT 2 -42 -PLT 2 94 188 E-1: NONSALES J/W 3 -32W -T8 ELECTRONIC BALLAST 7 62 434 E-1: NONSALES K/V - 1 -32W -T8 ELECTRONIC BALLAST 7 32 224 E-1: RESTROOM S - 3 -40W -E26 1 120 120 Retail Display Lighting from..LGT-INT -DISPLAY s u'?.`• + 3360 Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Watts 10084 Notes: 1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all fixtures. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Display Lighting - Space -by -Space LTG -INT -DISPLAY 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address SOUTHCENTER MALL Date 8/9/2013 2800 SOUTHCENTER MALL, SPACE: 408 For Building Department Use SEATTLE, WA 98188 Applicant Name: SHREMSHOCK ENGINEERING INC Maximum Allowed Display Lighting Wattage Location (plan #, room #, or ALL) Space Type* Allowed Watts per ft2** Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) E-1: SALES Retail 3: furniture, clothing, cosmetics, artwork 1.40 4083 5716 240 240 * Only areas within retail sales areas that contain separately controlled display light may be entered per Table C405.5.2(2) footnoteA. ** From Table C405.5.2(2) footnote A. Total Area Area Watts 4083 Display Allowance Proposed Display Lighting Wattage Only separately controlled display fixtures complying with C405.5.2(2) footnote A may entered here 5716 3360 Location (plan #, room #, or ALL) Display Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed E-1: SALES TRACK (7A CURRENT LIMITER) 3 840 2520 E-1: SALES TRACK (SA CURRENT LIMITER) 1 600 600 E-1: SALES TRACK (2A CURRENT LIMITER) 1 240 240 Total Proposed Watts 3360 Notes: 1. For proposed Display Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 3. List all display fixtures. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Interior Lighting Summary - Building Area Method LTG -INT -BLD 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address soUTHCENTER MALL Date 8/9/2013 2800 SOUTHCENTER MALL, SPACE: 408 For Building Department Use SEATTLE, WA 98188 Applicant Name: SHREMSHOCK ENGINEERING INC Do Not Enter Lighting Here. Use LTG -INT -SPACE Building Area Location (plan #, room #, or ALL) Area Description Allowed Watts per ft2* Gross Interior Area in ft2 Watts Allowed (watts/ft2 x area) * Lighting Power Allowances per Table C405.5.2(1) Total Do Not Enter Lihtine Here. Use LTG -I Building Area Location (plan #, room #, or ALL) Fixture Description (Include exempt equipment per Note 5) Number of Fixtures Watts/ Fixture Watts Proposed Notes: 1. Proposed Wattage for each Building Area type shall not exceed the Allowed Wattage for that Building Type. Trading wattage between Building Area types is not allowed under the Building Area Method compliance path. 2. Proposed fixtures must be listed in the building area in which they occur. Include ALL fixtures. 3. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information. 4. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and other criteria as specified in Section C405.5.1. For line voltage track lighting, list the greater of actual luminaire wattage or length of track multiplied by 50, or as applicable, the wattage of current limiting devices or of the transformer. For low voltage track lighting list the transformer rated wattage. 5. For lighting equipment eligible for exemption per C405.5.1, note exception number and leave Watts/Fixture blank. 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Exterior Lighting Summary LTG -EXT 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Proj Addres SOUTHCENTER MALL Date 8/9/2013 2800 SOUTHCENTER MALL, SPACE: 408 For Building Department Use SEATTLE, WA 98188 Name: SHREMSHOCK ENGINEERING INC Appl. Name 6130 S. SUNBURY RD WESTERVILLE OH, 43081 Appl. Phone 614-545-4sso Project Description ❑ Alteration ❑ Plans Included II New ❑ Addition Lighting Zone (as specified by Jurisdiction) O Zone 1 Zone 2 O Zone 3 0 Zone 4 Compliance Option O Lighting Power Density Calculations 0 Total Building Performance Building Grounds (luminaires > 100 Watts) ❑ Efficacy > 60 lumens/VV ❑ Controlled by motion sensor ❑'Exemption (list) Alteration Exceptions (check appropriate box - sec. C101.4.3.1) ❑ No changes are being made to the exterior lighting ❑ New wiring installed to serve added fixtures and/or fixtures relocated to new circuit Provide applicable exterior lighting controls (C405.2.4) and commissioning of lighting controls per C405.13 Tradable Maximum Allowed Lighting Wattage Base Site Allowance: Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft`), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Total Allowed Tradable Watts: Tradable Proposed Lighting Wattage (use mfgr listed maximum input wattage for luminaire.) Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Total proposed tradable watts may not exceed the sum of total allowed tradable watts plus Total Proposed Tradable Watts: the base site allowance. Any base site allowance not needed to make tradable watts comply can be applied to individual non -tradable categories. Non -Tradable Maximum Allowed Lighting Wattage Base Site Allowance Remaining: Fixture Description Non -Tradable Surfaces Description Allowed Watts per ft2 or per If Area (ft2), perimeter (If) or # of items Allowed Watts x ft2 (or x If) Non -Tradable Proposed Lighting Wattage Surface Fixture Description Number of Fixtures Watts/ Fixture Watts Proposed Non -tradable proposed watts may not exceed allowed watts for any individual surface unless the total excess watts for all non -tradable surfaces are less than the remaining site allowance. Total excess Non -Tradable watts: Site Allowance Balance: 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Lighting, y., r+Ui H. a(n �R •, _ - t '1& Y_k4` ,• A , ..- .,.'-..-,;,.,- Motor, sand Transforrner,Permit PlaynsCheckltiis�tLTG,CHK ._-_....,,,,A„. State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 2012 Washington Project Address SOUTHCENTER MALL Date 8/9/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2012 Washington State Nonresidential Energy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes LIGHTING CONTROLS (Section C405.2) Yes ® C405.2.1 Manual lighting controls Lighting control schedule with type, locations served, 50% lighting reduction method E-1 Yes C405.2.2.1 Automatic time switch controls Lighting systems automatic shut-off capability - indicate method and location served on plans. Note locations where automatic shutoff is provided by other method (occupancy sensor, daylight controls, etc) E-1 Yes Override switching Schedule with locations served - no single override switch exceeds an area of 5,000 SF E-1 Yes C405.2.2.2 Occupancy sensors Schedule of locations served E-1 C405.2.2.3 Daylight zones N.A. Vertical fenestration Primary and secondary daylight zone areas indicated on plans N.A. Skylights Skylight daylight zone areas indicated on plans N.A.Daylight %405.2.2.3.: zone controls Lighting control schedule with dimming method and locations served - no single daylight control zone exceeds 2,500 SF Yes C405.2.3 Specific application controls Specific application lighting controls are independent of general area lighting and controls for other lighting applications E-1 Yes Means of egress lighting Lighting control schedule with method and locations served. Note luminaires that function as both normal and egress. E_1 Yes Display lighting Lighting control schedule with type and locations served E-1 Yes Accent lighting Lighting control schedule with type and locations served E-1 N.A. Hotel/motel guest rooms Lighting control schedule with type and locations served N.A. Supplemental task lighting Lighting control schedule with type and locations served N.A. Non-exempt lighting equipment Lighting control schedule with type, applications served and locations N.A. Non-exempt lighting equipment Lighting control schedule with type, applications served and locations 0405.2.4 Exterior lighting controls Lighting control schedule with type, features and location served INTERIOR LIGHTING POWER (Section C405.5) Yes 0405.5.1 Total connected lighting power Schedule with fixture types, lamps, ballasts, watts per fixture E-1 N.A. Space exceptions Space exceptions taken noted on plans or compliance form Yes Lighting equipment exceptions Equipment exceptions taken noted on plans or compliance form E-1 Yes C405.5.2 Lighting power calculations E_1 N.A. Building Area Method Compliance form completed - proposed wattage per building area does not exceed maximum allowed wattage Yes Space -By -Space Method Compliance form completed - total proposed wattage does not exceed maximum allowed wattage E_1 Yes C405.4 Exit signs All internally illuminated exits sign are < 5 watts per side E-1 EXTERIOR LIGHTING POWER (Section C405.6) N.A. C405.6.2 Total connected lighting power Schedule with fixture types, lamps, ballasts, watts per fixture N.A. Exterior application exceptions Exterior application exceptions taken noted on plans or compliance form N.A. Lighting power calculations Compliance form completed - proposed wattage for exterior lighting plus base site allowed does not exceed max. allowed N.A. C405.6.1 Exterior building grounds lighting Schedule with fixture types, lamps, ballasts, watts per fixture; lumens per watt for fixtures > 100 watts 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Lighting, Motor, and Transformer Permit Plans Checklist LTG -CHK 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address SOUTHCENTER MALL 8/9/2013 8/9/2013 The following information is necessary to check a permit application for compliance with the lighting, motor, and transformer requirements in the 2012 Washington State Nonresidential Ene gy Code. Applicability (yes, no, n.a.) Code Section Component Information Required Location on Plans Building Department Notes ELECTRICAL POWER SYSTEMS (Sections C405.7 ,C405.9, C405.12, C409.2.1) N.A. C409.2.1 Electrical energy consumption — whole building Meters provided for whole building electric energy usage N.A. C405.7 Electrical energy consumption — dwelling units Individual dwelling unit electricity meters provided N.A. C405.9 Transformers Indicate transformer size and efficiency on plans N.A. C405.12.1 Variable speed escalators and moving walks Variable speed controls provided N.A. C405.12.2 Regenerative drives Variable frequency regenerative drives provided for escalators COMMISSIONING (Sections C405.13, C408.3, C409.4.4) N.A. C405.13 Commissioning Commissioning procedure developed for all applicable systems Yea C408.3 Lighting controls Commissioning plan and functional test procedure developed E-1, E- 3 N.A. C409.4.4 Electrical energy consumption meters Commissioning plan and functional test procedure developed N.A. Escalators & moving walks Commissioning plan and functional test procedure developed If "no" is circled for any question, provide explanation: August 21, 2013 Department of Community Development 6300 Southcenter Blvd., Suite #100 Tukwila, WA 98188 Attn: Bill Rambo, Permit Technician RE: MAURICES Southcenter Mall Store #2170 1071 Southcenter Mall SP# 408 Tukwila, WA 98188 ARCH PROJECT No.: 130453 Permit Application No.: D13-260 Mr. Rambo, SHREMSHOCK Architects & Engineers 6130 S. Sunbury Rd. Westerville, OH 43081 t 614 545 4550 888 373 4130 f 614 545 4555 www.shrcnuhock.com RECEIVED CITY OF TUKWILA AUG 2 3 2013 PERMIT CENTER Itemized below are responses to the Building Department Comments dated August 13, 2013: Responses to Review Memo: Comment 1: Some code references are not correct on the plan set including the engineering plans which specify 2009 codes govern. As of July 12013 City of Tukwila adopted the 2012 International Building codes. Provide revised plan sheet documents showing compliance with the current 2012 International Building codes with Washington State Amendments to include 2012 UPC, IMC, 2008 IEC, 2012 WSEC, 2009 ANSI and current local City of Tukwila codes. Code references shall be shown on the cover sheet. All other plan set code references and details shall also reference current codes. Arch. Response: Updated project data on cover sheet to properly reflect current Washington state amendments for the city of Tukwila Comment 2: INCOMPLETE LTR#f I Provide a floor plan that identifies means of egress. Dimension egress paths. Identify path of egress illumination on the plan to show common paths of egress are provided with emergency illumination. Emergency illumination shall have at least an average I foot-candle and a minimum at any point of 0.1 foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required for exit discharge doorways. (IBC Section 107.2.3, 1006 & 1008.1.6) Arch. Response: Added common egress paths to sheet A-3 including dimensions Eng. Response: Added sheet E-5 "Egress Photometric Plan" to show common egress paths with required emergency illumination Thank you, David Scott Shremshock Architects and Engineers, Inc. 2 of 2 REVISION DOCUMENT SHREMSHOCK Architects & Engineers 6130 S. Sunbury Rd. Westerville, OH 43081 t 614 545 4550 888 373 4130 f 614 545 4555 www.shremshock.com PROJECT BULLETIN No. 2 08/21/2013 MAURICES Southcenter Mall Seattle, WA Store #2170 1071 Southcenter Mall SP# 408 Seattle, WA 98188 ARCH PROJECT No.: 130453R2 To the Contractor: This bulletin, issued after the execution of the contract, describes proposed revisions of the contract documents and requests from contractor the amount of change, if any, in contract sum to accomplish the work described. It is assumed no change in contract time will be necessary unless contractor submits written request for time extension, including justification, with his proposal for work described in this bulletin. Except, as otherwise described herein, or as shown on drawings issued with this, current contract documents apply to proposed work. This bulletin is not an order to do work. After receipt and review of the proposal requested, a change order will be issued to authorize execution of the work, or portion thereof, if the owner so directs. REASON FOR REVISION: BUILDING DEPARTMENT COMMENTS Submit proposals for the change described herein on Contractor's letterhead. List each item individually as listed below. DRAWINGS INCLUDED WITH THIS BULLETIN: A-1, A-3, A-4 and E-5 DRAWING REVISION PROPOSALS: A-1 COVER SHEET: • Project Data o Revised Code Summary to indicate code compliance with current 2012 International Building Codes with Washington state amendments per building department comments A-3 CONSTRUCTION PLAN: • Added "Egress Corridor" to plan to identify means of egress per Building Department comments • Added dimensions to Egress Corridor per Building Department Comments • Indicated common paths of egress on sheet per Building Department Comments • • • Added Non -sales Keynote 101 to sheet indicating 44" min. path of egress provided per state and local codes A-4 REFLECTED CEILING PLAN: • Added "Egress Corridor" notation on plan to identify means of egress per Building Department Comments • Added "Mall Corridor (N.I.C.)" notation to plan to identify means of egress per Building Department Comments E-5 EGRESS PHOTOMETRIC PLAN: • Added sheet to set per Building Department Comments END OF REVISIONS INITIALS: D. Scott (Arch.), Jeff Hampton (Ele.) 2 of 2 August 13, 2013 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Tim Schenk Elder -Jones Inc 1120E 80`h St, Suite 211 Bloomington, MN 55420 RE: Incomplete Letter #1 Development Permit Application Number D13-260 Maurices —1071 Southcenter Mall Dear Mr. Schenk, This letter is to inform you that your permit application received at the City of Tukwila Permit Center on August 12, 2013 is determined to be incomplete. Before your application can continue the plan review process the attached/following items from the following department(s) need(s) to be addressed: Building Department: Allen Johannessen at 206 433-7163 if you have any questions regarding the attached comments. Please address the comments above in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that four (4) sets of revised plans, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, please contact me at the Permit Center at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File No. D13-260 jois W:IPermit Centerllncomplete LettersI20131D13-260 Incomplete Letter #1.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Tukwila Building Division Allen Johannessen, Plan Examiner Building Division Review Memo Date: August 13, 2013 Project Name: Maurices Permit #: D13-260 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. 1. Some code references are not correct on the plan set including the engineering plans which specify 2009 codes govern. As of July 1 2013 City of Tukwila adopted the 2012 International Building codes. Provide revised plan sheet documents showing compliance with the current 2012 International Building codes with Washington State Amendments to include 2012 UPC, IMC, 2008 IEC, 2012 WSEC, 2009 ANSI and current local City of Tukwila codes. Code references shall be shown on the cover sheet. All other plan set code references and details shall also reference current codes. 2. Provide a floor plan that identifies means of egress. Dimension egress paths. Identify path of egress illumination on the plan to show common paths of egress are provided with emergency illumination. Emergency illumination shall have at least an average 1 foot-candle and a minimum at any point of 0.1 foot candle measured along the path of egress at the floor level. Emergency lighting shall also be required for exit discharge doorways. (IBC Section 107.2.3, 1006 & 1008.1.6) Should there be questions concerning the above requirements, contact the Building Division at 206-431-3670. No further comments at this time. 'PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-260 DATE: 08/23/13 PROJECT NAME: MAURICES SITE ADDRESS: 1071 SOUTHCENTER MALL Original Plan Submittal X Response to Incomplete Letter # I Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: B ' II Ing Division g-i 3 Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 08/27/13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 09/24/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW ❑ Staff Initials: � PERMIT COORD COPY r PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-260 DATE: 08-12-13 PROJECT NAME: MAURICES SITE ADDRESS: 1071 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEEPARRTMENTS: Building Division SubII c Mk Fire Prevention Structural • AYfr Planning Division Permit Coordinator or I DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete n Incomplete DUE DATE: 08-13-13 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: 9-,7)--I-2) LETTER OF COMPLETENESSMA)LED: Departments determined incomplete: Bldg ISk Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route n Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 09-10-13 Approved with Conditions n Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 • PLAN REV EW CHECKLIST - (Nonstructural) By: Date: —210-li Permit App. ! 7 ` 26 d IBC Edition /„,Z & State Amend. Project title: +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Classify the building or portion thereof in accordance with Chapter 3 —betermine the type of construction of the building in accordance with Chapter 6. Determine if the location of building on the site and clearances to property lines and other buildings on the site plan are in accordance with code provisions. Review for conformity with General building height and area limitations in accordance with Chapter 5. view for conformity with special detailed requirements based on use and Occupancy. �/�eview for conformity with Type of Construction requirements of Chapter 6. j Review for conformity with Fire and Smoke protection features of / Chapter 7. Review for conformity with requirements of interior finishes of Chapter 8. Review for conformity with requirements for fire protection systems of Chapter 9. /trIReview for conformity with requirements for means of egress requirements of Chapter 10 Review for conformity with requirements of accessibility in accordance with Chapter 11, and ICC A117.1 Review for conformity with Washington State Energy Code. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ✓ In circle = topic has been reviewed for the application. X In circle = topic is not relevant to proposed scope of work. • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 981'88 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: `ZZ ` l� Plan Check/Permit Number: D13-260 • Response to Incomplete Letter # 1 ❑ Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Maurices Project Address: 1071 Southcenter Mall Contact Person: TI PA Scoer4k- Phone Number: 9.5.2 .1qS•l00� RECEIVED CITY OF TUKWq,A AUG 2 3 2013 Summary of Revision: SErc Ati Cl- D�.r.5edr(sec.,c Sheet Number(s): - ,4 3 A .4 "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: gr.- Entered in Permits Plus on At() \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: Contractors or Tradespeople Per Friendly Page General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name J E M CONSTRUCTION INC UBI No. ' 601770782 Phone 2538432765 Status Active Address 29506 8Th Ave S License No. JEMCOI*033DD Suite/Apt. License Type Construction Contractor City Roy Effective Date 3/4/1997 State WA Expiration Date 5/15/2015 Zip 98580 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date MILLER, JAMES E President 01/01/1980 Amount Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 CBIC SA7695 03/01/2002 Until Cancelled $12,000.00 03/19/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 14 American States Insurance Co 01C12205495 04/16/2013 04/16/2014 $1,000,000.0004/11/2013 13 American States Insurance Co 01C12205491 04/16/2011 04/16/2013 $1,000,000.0004/13/2012 12 AMERICAN STATES INS CO 01C1220549 04/16/2009 04/16/2011 $1,000,000.00 04/21/2010 11 AMERICAN STATES INS CO 01C1220549 04/16/2009 04/16/2010 $1,000,000.00 04/17/2009 10 0010 CAS INS BL053040470 12/02/2008 12/02/2009 $1,000,000.00 11/20/2008 9 OHIO CAS INS BL00353040470 12/02/2003 12/02/2008 $1,000,000.00 11/27/2007 Summons/Complaint Information Cause County Complaint Judgment Status Payment Paid By 10-2-11928-6 BROOKDALE LUMBER INC InterPlead: No PIERCE Date: 08/16/2010 Amount: $10,795.92 Bond(s): SA7695 Date: Amount: $0.00 Dismissed Date: Amount: Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print. aspx 09/17/2013 TASK RESPONSIBILITY LIST NO-=_ U TA . GN E =. LEGEND: C. = E -=....'E T &. X=\GT L INSTALLED C3' REMARKS TASK RE5PON51BILITY LIST CONTINUED FINISH SCHEDULE LIGHT SCHEDULE DI ISION 1 ENSR RE ENTS INSURANCE TO G`ETAINNEC ARY rFER: !TS G MAI ..F TE* F'C RAR ` UTIL I } 1E5 TEMPO 5`1"ARRIGAa5 ,f_. S1OR iEF NT IsI 5I t_ START GE TIF ATE 1EAN? R TO- DEPARTING 51 'U1_I L ='ter _EGT T i E I NTINUQtSi OVA_ L7 GONSrROr.. TION G ROFESSIONAL LEANING E PRIOR TO TU G ISIcN 2 SITE iistO OLITION _ITT T5 ANDIC • TCS -E: REMO E -XIS T TNG SIGN .' FAC EFAI BAND' G ION S CONCRETE GRAVEL S X x GONGS 'G B RR:I R FILL 5 O: UTS G DA AGEL 'AREAS: EATH-TONE F TOFF TNG SLA FCR STOREFRONT SEGTYY: X X DIVISION 4 AWN" CONCRETE BLOCK ERIGIK STO • go; II'ISIcN 5 METALS FRA:~ING Of DEMISING- A UNL3ILE OF LCC): FRA TNG EXIT t R JP INTERIOR -FARTIT.IONS - • A -S 5 FRA! T C. FRA 3+ INC C STC REF T (T0UND IL'E CrF E FRAMING. CSF GE! NG 5I'TIoNS c ALL STAND/P-0'5 AT SAP AREA STANDARDS AT`N1 _ES G cE SA' AREA STANDARD ERAS AND: . STiUC:TURAL FR INE SIGN GRID AT STC! NT DI" ISIO 6 "OOD AND PLASTICS ALL g tINAT T 5T NG JAMES AN SALE -SALES: SISI G G DOOR BUMPERS AT F BACKP r I ARD ARE ,fG EASE AT SA=LES .A SALES A INC RCf M DIVLSION TH ERMAL AND MOISTI RE PROTECTION ROOF F.ETR T IONS ROOF CURE ATHER: IF G AND INSULATION AT E> :I .IQR DOORS X X: FI TQF.. FING. SOUND A AT ICON EA t 5. X X INSOLATION -EXTERIOR Y&A: 5 X X I'st'ISIC N S DOORS AN REAR SECURITYDOOR, > D I- #AR?IARE G DOOR SGIE:7ULE MISC. Nr NSAM F OGRS ANL? ARDiNARE E G SEE D SGHET7ULE FITTING M D'O'ORS -IARDP ARE G'. St E'L?OOR SGs+EDUL HAI A EGA Doc IiaEL3 EY MAURICES S DOOR SCHEDULE JAMES 4 R'STG FOR ?* AURIGF FRietVIDED DOORS STC REF T ALU U EASE 4 5 ST TREF NT GLAD CIEMP�) 3-Y 1RROR FIEING: I AND C.AULI Ii�3C SNAPI DOOR FRAMES SALES;>FI gTOREFRONT L]C31 G DIVISION qI=I1`IIS ES GYP ELS AT L SI TO DECK GYr AT EXIT RIDOR G'YF ED AT INTERIOR 407IALLS GYF ED'G."ILING/5 g<HEA F CAT ED CIL MALL FL TILE AND BASE ON -S FLOOR TILE, A55E AN A SALES A FLC TIi TIL JT F 5 IG TILE SAI AREA CARPET EASE X: G AL:1 #ESI m GAS FAD, AND SEAM SEALER TRANSIT! NSIT! S: AT SALES/ ALS: t TION S.RIr AT ST AL AW .STICAL CEILING T -Ga ID4:: A-4 ACOUSTICAL CEILING TILE 5 + NC N -SALES AREAS FAINT AND .I` E'e"+ SPECS: G STQI 'TDO FAINT' .AND PRIMER F .G5: STAIN ERINGS PRIME ANLL PAINT. L STAN ARDS TI` 5 REI FORGED PANE RP)' 1;;I" ISION E IALTIES ATE ON:AGE A & X'& LIG T 5 X VINYL STOREFRONT �1= ELAL E SIGN X :X SALE= '; .00 Qyy Y" SIGN SEE 1O'OR SCHEDULE ONSALEs STC" A 'E SYSTEM C REA .E ILTIEItTI SIGN d SAN ILENTIE !CATION I HANG FT G E'SIGNLDER X X _G ox X X ROA' IL E EA.NNER X EF4 IT FJAtILL=1. x EA I6A17E. SIGN _ 01500 -SALES HA _>A1_11/A . 51T DEVISIc N 12 I=LI NIS14IN 5 SET -}I • JOIN UNITS, FITTING AI G: I i INC TIS E FAF E REST C (24' 3+ 'ANN9 NII 'RIGERATOO„. SELF AND !-TANG EAR FOR OW GLOB,;; X X GOAT -I ocKs< SALES AREA i}AA-.ME 1 P E LCL `r (2 -1 k: ) STCREF' 4T i"% LSC. SHADES X FITT! RMFNT HANG EARS N 15 SPECIAL CONSTRUCTION MUSIC SYSTEM SIRING (INGLUD 6•• FINAL UP). MUSIC SYS7EM EQUIPMENT, SFEAKBR5 TRAFFICG JN t;ER(5) EGOIrMalI .TRAFF.IG COU N I EFS CON L UIT AND I IRINS : G T. RAF:= IG COUNT; INSTAL Lar L. SSE c: L T :L •A(R'. E CONDUIT DIKING TO THE;, G E3 . MAaRK PAS E ,.rA° GR` S GOA/ FLATES, ; I :TNG AND GC NNE €IONS ST ONE S UN H DO BLOCK GAT 5 SIRING 6:G_ TO. ST Ste, FULL€,,TIONS IF GSE REL? ANL? ROU1 (INSTALS 2S F!QR TGA TURNOVER) DISION 14 NVEY1NG, SYSTE.!S ISION 15 MEHANIC,AL HVA& SYSTEM SEE SAS _INE ' AND FADS TO I4VAG WN 'SATE LINE TO a'A& SEE _- . IR1N 5 :TO 1-IVAG G THERMOSTATS DUCT GE ALL E1LT IFFUSt AND GRI. ?Yz ExH. aT FAN AT REST sTO VFJZIFY OPERATION GES T T -#E SPACE 51 AND ROUGH -IN IN ACE F'LUMEING' FIXTURES yeRIFy OF TIC COMPL L- t 1. FL °G SYSTEM SPRINKLER SYSTEM MAIN, 5 D ANL E. REVISIONS TO NCL ,:-.5y5Tem REMISE AS REQUIRED; FEEXTINGUI E FI ONSALES A 7--A GAS UNI HEATER B.:EG IG DUIT TO THE c• AGE 5 -17 YIN TRAN DISTRIBUTION PANELBOARD E-5 POS LOCKOUT GI IT ITS AN AN HVA MOTION TING GONTA TOR LUORESCENT LIGHTING, LIGHTING LW NA EXIT SIC -N5 EUZ7LBR5, NCLUDIN c" ITCH AT SMOKE TIME GLOG FORSTOREF 7 SIGN TROOM NEERS ONbl ITIES FOR PHONE LIN7C,/ 6, AN -LACKS I DINA NUFACTURER DE I TION PAINT AINT PAINT ANCESTRAL R1426 OR ra'uAL 5 45 BELIZE STAIN R014 AND FLOOR ENAME . EDE Ay COLOR PAINT ACK TIE 4c5A1001 OR eGUAL OLYU ETHANE 900 PRO EC AL YD EMULSION 6LOSS I TA PAINT. PANT R519 PIHI /414.4 LOS'S IN VINYL, ACRYLIC SHE MINDFUL ORAY ORMICA PION' E 5Rusi-tED ALUMINUM VNYL DAVE NIIE 4' :r.41 COVE ASE-OROINN pL. TIC FLEX LAS o LVT Tx 4a VCT COOL 1.04-IITE -1;51,a99 VCT COLORADO STONE 51506 2. ALL PAINT SHALL:BE 'VINYL ACRYLIC E6,6,5HELL rit-eRe OTHERINI5E NOTED. 5. PROTECT C014;IPLETED F NemEs FROM CONSTRUCTION DAM/416E. 4. NO VERTICAL 6RkDE LAmNATEs a -FALL OE USED ON ANY ORTION OF The PROJECT. DES- I LAMP REMARK INC) TRACK TRACK LEDi TRAr LED 1 PAR 30 TRACK EA INHITE FINISH CuRy 54E-240. FH LIPS FLT•42rt/ 2X2 F; 2/F032 /-7•35/ECOtb 48," FLUOR. STRIP ENC__G BALLAST METALUX ARO- EASE, FROSTED, TORPEDO, 2X4 2X4 FaIOR TROFFER f't/ 3" LiEEP LENSE Al LENT TROFFER Al 3" &ELL ENT SIGNS A/ PACK 2 HEA EALLA ENDANT 1 FFLOR. STRIP TER - FIXTURE • T UAL VOLTA6E _40 11) POOR HARDINAIRE SCHEDULE DOOR SCHEDULE 1. FITTING ROOM POOKS) a) MOUNT ALL DOORS AT 8" AFF. b) SUPPLIED NIITH DOOR - SUFACE MOUNTED TOP, MID AND BOTTOM DOOR HINGES. c) SUPPLIED INITH DOOR - LEVER HANDLE LOCKSET WITH PIN HOLE. d) DOOR 4 WALL MOUNTED 3" MAGNEnC DOOR STOP (REFERENCE DRAINING A-3) 2. SALES TO CORRIDOR DOOR a) PUSH / PULL PLATE SATN STAINLESS STEEL 0532D. 1 1/2 PAIR, SURFACE MOUNTED 33/2"x 3 NON -BALL BEARING SATIN STAINLESS STEEL U5320 HINGES b) LCN4041-AUJM CLOSER WITHOUT HOLD OPEN, MOUNTED 01•1 HNGE SIDE, SATIN STAINLESS STEEL U532D c) DOOR BUMPER d) KICK -STYLE HOLD OPEN!, IVES ttF5544, SATN SILVER FINISH 3. CORRIDOR TO NON -SALES DOOR (UPGRADE IF NOT EXISTNG) a) PUSH / PULL PLATE 5ATN STAINLESS STEEL US32D b) 1 1/2 PAIR, SURFACE MOUNTED 3 Yyx 3 Y2" NON -BALL BEARNG SATIN STAINLESS STEEL U532D HINGES 1 1/2 PAIR, SURFACE MOUNTED 4" x 4" BALL. BEARING SATIN STAINLESS STEEL HINGES IF FIRE RATED DOOR c) LCN4041-AUM CLOSER WITHOUT HOLD OPEN, MOUNTED ON HINGE SIDE, SATN STAINLESS STEEL d) DOOR BUMPER (IF REQUIRED) e) KICK -STYLE HOLD Ol'EN, IVES *F5544, SATIN SILVER FNISH 4. REST ROOM DOOR (UPGRADE IF NOT EXISTING) a) LOCK SET WITH PUSH BUTTON ON INTERIOR SIDE, LEVER DESIGN, SATIN STAINLESS STEEL U532D b) 1 1/2 PAIR FULL MORTISE, 3 Yy X 3 Y2", NON -BALL BEARING, SATN STAINLESS FEE.L US32D HNGES. O DOOR BUMPER 5. CORRIDOR TO MALL CORRIDOR DOOR (G L. TO UPGRADE HARDWARE IF NOT EXISTNG) a) DOOR ALARM SYSTEM EXISTING, MODEL 250, ALARMED PANIC LOCK WITH PADDLE. 1 1/2 PAIR, HAGER 131311qq (OR EQUAL) SURFACE MOUNTED 4 Yy X 4 Y2" BALL BEARING STAINLESS STEEL HNGES II/ NON -RISING REMOVEABLE PINS b) SURFACE MOUNTED FULL MOUNTED ON NTERIOR, 46" AFF TO CENTER, GRANGER 410E11, 5 3/4" X 1 1/2", FINISH BRIGHT ZINC.. c ) BLANK OFF ANY EXISTING EXTERIOR KEYWAYS. d) ONE WAY VIEWER, IVES 4t6q8. • CWSER WITH HOLD OPEN MOUNTED ON STORE SIDE, SATIN STAINLESS STEEL #U532D. f) LATCH PROTECTOR, DON -JO NLP -111-630, 31N X 11"H (OR EQUAL/ g) PAINT STORE SIDE OF DOOR (ONLY) FINISH " A ". h ) KICKPLATE STORE SIDE OF DOOR, FINISH "V", START Y2" FROM FROM BOTTOM OF DOOR, EXTEND UP 20" AND WITHIN 1" OF POOR SIDES. b. STOREFRONT WOOD MOWS) a) DOOR PULL PLITH q" MAX SPACED MOUNTING POSTS. PULL ON BOTH SIDES OF DOOR. b) CRL 1r1113 DOOR RAIL FLOOR LOCK, DEADBOLT IN BOTTOM RAIL OF EACH DOOR, KEYED ON OUTSIDE, THUMB TURN ON INSIDE a) 2 PAIR (4 HINGES / DOOR), BALL BEARING STAINLESS STEEL HINGES IN/ NON -RISING REMOVABLE PINS, MAT SILVER. d) U -CHANGE LOCK, FURNISHED BY MAURICE', INSTALLED BY G.C. e) 2 FLOOR MOUNTED DOOR STOPS f) RC-CESSED FLOOR MOUNTED BOLT POCKETS INITH SPRING LOADED COVER PLATES (2 PAIR) g) DOOR KNOCKER FURNISHED BY MAURICE), INSTALLED BY G.C., CENTER IN CIRCULAR AREA NUMBER DOOR SIE DOOR MATERIAL FINISH NOTE5 FRAME MATERIAL FINISH DETAIL NUMBER HARDWARE SET DOOR RATED REMARKS WOOD 3" MAGNETIC DOOR STOP WOOD 4-;\ 3 • METAL 713\ 2 G .0 TO INSTALL NON -SALES DOOR CHIME, FURNISHED BY MAURICE) AND "EMPLOYEES ONLY" DECAL ON SALES SIDE OF DOOR (E) 3-0" X 1-0" PAIR OF YVOOD 1,41000 METAL WOOD 4 3 4 METAL METAL METAL 3 4 5 6 G L. TO INSTALL NON -SALES DOOR CHIME, FURNISHED BY MAURICE, AND "EMPLOYEES ONLY" DECAL ON SALES SIDE OF DOOR STORE NAME IN 3" HIGH HELVETICA MEDIUM LETTERS (RED VINYL WITH 1^11-1ITE LETTERS) AT 6-0" PER MALL REG:UIREMENTS DOOR NOTES 1.) NEN DOOR SUPPLIED BY MAURICES, INSTALLED BY CONTRACTOR 2.) NEN DOOR SUPPLIED AND INSTALLED BY CONTRACTOR. 3.) NEW DOOR SUPPLIED AND NSTALLED BY LANDLORD. 4.) EXISTING DOOR, LI- TO REFINISH PROVIDE / REPLACE AND INSTALL ANY MISSING HARDINARE NOTE: DOOR FINISH APPLIES TO BOTH SIDES OF DOOR UNLESS OTHERNIISE NOTED. • SPACE 408 LEVEL 1 OF 1 MALL PUBLIC REST ROOMS -1350' KEYPLAN GENERAL. NOTES PROJECT DATA INDEX OF DOCUMENTS 1. CONTRACTOR SHALL VERIFY ALL SITE DIMENSIONS, COMPLETE SQUARE FOOT VERIFICATION FORMS AND RETURN TO MAURICE5 PROJECT MANAGER WITHIN 2 DAYS TO ENSURE CONFORMITY WITH DESIGN A5 DRAWN. NOTIFY MAIRICES OF ANY VARIATIONS 2 TENANT'S CONTRACTOR MUST HAVE CASHINRAP INSTALLED FOR CAT 5 INSTALLATION TO TAKE PLAce 1 WEEK BEFORE PUNCH. SISE FOS EQUIPMENT INSTALL DETAIL ON ELECTRICAL DRAWINGS. DEMISNG WALLS ARE THOSE vficH SEPARATE MAURICE, SPACE FROM ADJACENT SPACES. INTERIOR WALLS ARE THOSE WITHIN MAURICE, LEASED SPACE. PROVIDE WTYPE "X' GYP. BD. SEWRITY BARRIER ON LEASED PRE1415E SIDE OF ALL DEMISING PARTITIONS AND STOREFRONT, EXTEND TO ROOF DECK. IF GYP. BD. 15 NOT ALLOWED G.C. TO SECURE SPACE MIN WIRE MESH FROM TOP OF WALL TO ROOF DECK 5. SLAB SHALL BE FLOOR STONE / LE/ELED AS REQUIRED TO ASSURE SMOOTH AND LEVEL SURFACE. CONTACT MAURICE5 PROJECT MANAGER OF UNUSUAL PREPARATION WORK. 6. ALL GRILLES, CLEAN -OUTS, PLATES, ETC. IN SALES AREA SHALL BE FINISHED TO MATCH ADJACENT SURFACES. 1. DO NOT PAINT SPRINKLER HEADS. PROTECT ALL SPRINKLER HEADS FROM ovER SPRAY. 8. ALL HVAC SYSTEMS MUST BE TUIRNED OFF OR RETURN AIR GRILLES COVERED Y.IITH FILTER MATERIAL DURING ANY DUST -PRODUCING ACTWITY, INCLUDING, BUT NOT LIMITED TO, DEMOLMON AND GYP. BD. SANDING. ALL BRACING, STRUCTURAL CONNECTIONS AND MISC. WORK SHALL BE OF NON-C,OMBUSTIBLE MATERIALS WHERE REQUIRED BY CODE OR LANDLORD. 10. DO NOT PUNCH OR USE ROOF DECK TO SUPPORT ANY ITEMS. CEILING GRID, MECHANICAL, ELECTRICAL, LIGHT FIXTURES, ETC. SHALL BE SUPPORTED FROM STRUCTURAL ROOF MEMBERS. 11. APPLY A CONTINUOUS CLEAR SILICONE PERIMETER BEAD BEHIND H.C. FITTING ROOM MIRROR, ALL FTMNG ROOM DOOR CASINGS, IN ENTIRE FITTING ROOM BANK AND FITTING ROOM SIGN HOLDER. SILICONE SHOULD NOT BE VISIBLE 12 GENERAL CONTIRACTOR SHALL OBTAIN CERTIFICATE OF OCCUPANCY FOR THIS PROJECT PRIOR TO DEPARTING SITE.. a CONTACT MAuRIcES PRoJECT MANAGER (218) 12/-8431 FOR DISPOSMON oF Au. EXcESS UNUSED ITEMS SUPPLIED BY TENANT OR SALVAGEABLE MATERALS. 14. CONTRACTOR IS TO NOTIFY MAURICES IMMEDIATELY OF ANY C.ANTRADICTION OR AMBIGUITY WITHIN THE DRAWINGS OR SPECIFICATIONS. MAURICE, 15 TO RENIDER FINAL DECISION REI-ATEID TO THE INTENT OF THE CONMUCTION DOCUMENTS. AREA 4 as 1010 TOT 2000 1EC 711114 STATE AMMENDME4T5 TOTAL ANGY "6 0413 CONS LI SEPARATE PERMIT REQUIRED FOR: iirbleChanical Vas Piping C:!V of Tukwila A-1 COVER SHEET A-2 DEMOLMON PLAN A-3 CONSTRUCTION PLAN A-4 REFLECTED CEILING PLAN A-5 ENLARGED STOREFRONT PLAN AND ELEVATIONS A-5.1 STOREFRONT SECTIONS AND DETAILS A-6 SALES AREA INTERIOR ELEVATIONS A-6.1 FITTING ROOM INTERIOR ELEVATIONS A-1 NALL TYPES AND DETAILS / NON -SALES EQUIPMENT ASSEMBLY A-8 DETAILS A-1 SPECIFICATIONS A-10 SPECIFICATIONS A-11 SPECIFICATIONS FILE: COPY Permit No. Mtn rry:SAI approval is subject to errors and elisions. i:o! of construction documents does not authorize any adopted code or ordnance. Receipt LgNoTad Field Copy and condkions is acknovaledged: E-1 ELECTRICAL LIGHTING PLAN E-2 ELECTRICAL POIAIER PLAN E-3 ELECTRICAL SPECIFICATIONS E-4 CTR CAL PI VOLTAGE PLAN E-5 EGRESS PHOTOMETRIC PLAN M-1 MECHANICAL PLAN M-2 MECHANICAL SPECIFICATIONS 5-1 STOREFRONT SPECIFICATIONS AND NOTES 5-2 STOREFRONT FRAMING PLAN AND SECTIONS 5-3 5TRUCTURAL CONSTRUCTION DETAILS REVIEWED FOR ODE COMPLIANCE APPROVED 1 REVISIONS No changes shall be made to the scope CI' r;ork without prior approval of 1 Tu%vviIa Building Division. i i.2 -,i; mai infr.,%-le additional plan review fees. 1 BUILDING DIVISION SEP 0 5 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 2 3 2013 PERMIT CENTER P 1.2.1e40 LU CNI fx 00 (1) I- 2 (I) u)(1 • 1--- Ull LU D' ' ) - •• 01 rii u) i CV D co ,_ .. ‘•• AUG 2 1 2013 0 LIS w w LI F:614.545.4555 cc 0 Lll 0 0 to 0 0 co CD LLI 8 UJ co U) 4n Lim <C 1-1-1 °° Z 00 mm) LU 0 < co z it E ,_ . . , n o JOB NO. 2170 DATE: 08-21-18 STORE TEAM: APPROVED BY : XX REVISIONS: REV tt1 0-16-2013 DE35 REsv it,2 8-21-2013 DM COVER SHEET SHEET A-1 OF 23 SHEETS MALL CORRIDOR COL OEXISTING CONDITIONS / DEMOLITION PLAN KEYNOTES 1 EXISTING TENANT DEMISING WALL TO REMAIN. G.G. TO PATCH AND REPAIR SURFACE TO LIKE -NEW CONDITION. PREPARE EXISTING WALLS TO RECEIVE NEW FINISHES, INCLUDING LAMINATING WALL WITH 1/2" GYP. BD. IF NEEDED, INCLUDING ALL AREAS THAT CURRENTLY HAVE SLATWALL 2 LANDLORD TO DEMOLISH EXISTING DEMISING WALL AND NEUTRAL PIER A5 INDICATED. MAURIGES G.C. TO NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES OR IF FIELD CONDITIONS VARY FROM WHAT 15 SHOWN IN THESE DRAWINGS 3 ASSUMED LOCATION(5) OF EXISTING STEEL COLUMN(5). VERIFY SIZE AND SPACING OF ALL STEEL COLUMNS AT TIME OF DEMOLITION. NOTIFY ARCHITECT IMMEDIATELY IF STRUCTURE DIFFERS FROM WHAT IS SHOWN ON PLANS 4 LANDLORD TO DEMOLISH ALL PREVIOUS TENANTS PARTITION WALLS, CEILINGS, SOFFITS, DOORS AND FRAMES, WALL CABINETS, SHELVING, WALL STANDARDS, COLUMN ENCLOSURES AND FINISHES AS INDICATED (U.O.N.). PROTECT ALL MALL NEUTRAL PIERS AND DEMISING WALLS DURING DEMOLITION. REFER TO CONSTRUCTION PLAN A-3 FOR NEW WORK 5 N/A b EXISTING EXTERIOR H.M. DOOR AND FRAME TO REMAIN. G.G. TO PROTECT DURING CONSTRUCTION. REFER TO CONSTRUCTION PLAN ON A-3 7FINISHES LANDLORD TO REMOVE ALL CARPET, TILE, VCT AND ANY EXISTING FLOOR THROUGHOUT LEASED SPACES AND PROVIDE TENANT WITH AN UNFINISHED, LEVEL CONCRETE SLAB FREE OF HAZARDOUS SUBSTANCES, READY TO RECEIVE FLOOR AND NEW TENANT FINISHES 8 EXISTING TOILET ROOM TO REMAIN UN -TOUCHED. G.G. TO UPGRADE FINISHES A5 SCHEDULED. REFER TO CONSTRUCTION PLANA -3 AND PLUMBING DRAWINGS FOR SCOPE OF WORK 5 LANDLORD TO DEMOLISH EXISTING STOREFRONT WALLS, HOARDING, GRILLES AND GLAZING AS INDICATED. REFER TO CONSTRUCTION PLAN A-3 FOR NEW WORK 10 LANDLORD TO DEMOLISH EXISTING RTU -1 AND DUCT DROPS. REFER TO MECHANICAL DRAWINGS FOR NEW WORK 11 EXISTING RTU -2, DUCT DROPS AND MAIN DUCT BRANCH TO REMAIN FOR RE -USE. REFER TO MECHANICAL DRAWINGS FOR NEW WORK 12 G.G. TO DEMOLISH EXISTING SECONDARY DUCT, FLEXIBLE CONNECTIONS AND MECHANICAL ACCESSORIES. REFER TO MECHANICAL DRAWINGS FOR NEW WORK 13 EXISTING RTU -1 MAIN DUCT BRANCH TO REMAIN FOR RE -USE. REFER TO MECHANICAL DRAWINGS FOR NEW WORK ADJACENT TENANT (N.I.C.) 14-15 lb B4O, EXISTING MALL BULKHEAD AT ±14'-0" A.F.F. TO REMAIN, G.G. TO PATCH, REPAIR AND PREPARE SURFACES TO RECEIVE NEW TENANT FINISHES. G.G. SHALL NOTIFY MAURICE , CONSTRUCTION MANAGER AND ARCHITECT IMMEDIATELY OF ANY UN-FORSEEN CONDITIONS OR IF EXISTING CONDITIONS VARY FROM WHAT 15 SHOWN IN THESE DRAWINGS. REFER TO STOREFRONT SECTIONS ON SHEET A-5.1 1/-15 N/A 15 EXISTING MALL. NEUTRAL PIER TO REMAIN (N.I.C.) 20 EXISTING ELECTRICAL SERVICES TO BE COMBINED / UPGRADED. TENANT G.C. TO CUT AND CAP UN -USED SERVICE. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION AND EXTENT OF NEW NOW 21 TENANT G.G. TO DEMOLISH UN -USED / ABANDONED ELECTRICAL PANELS AND EQUIPMENT. REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION AND EXTENT OF NEW WORK 22-25 N/A ±15'-6" REFER TO CONSTRUCTION PLAN ADJACENT TENANT l L r J I_ (E) RTU -2 17 '71 miIII Illim L'J I II ' - X eco (E) RTU -1 F '711 III � III / J 7_ / / / IF III III WALL HATCH INC COL NOTES ADJACENT TENANT bi 0 (0O F- 0 W ZM Z i _ CV D o0 J - Dc'J 0 r EXISTING MALL CONCOURSE I REVIEWED FOR CODE E COMPLIANCE APPROVED SEP 0 5 2013 City of Tukwila BUILDING DIVISION 0 1' 3' COL 2 4' SCALE: y4" _ 1'-0" 1{N' C,AT , \ En N I iA L, G: gid. TO CH Z WAR r !°E3.. ANY i.E 2 .'�:•7:'e •\�F�T4-+:`? t��%„' %�w rr�7:�' TO �..neur..: �T tv�l Kai E :�l ;E`?a.�. ] xpLATri5 .Exe-r4Nc NALL TO BE REMOVED BY C;, .. 1 F 'NTRAtw�� 7 M,sVT=o- E SITE TO VERIFY EaIi7NG CONDITIONS AND ,�\�TT;S E.,VES ?EH ALL =lGtiF I UNDER T R SCOPE AS ~sD CUT IN .HE LEASE ,„�EN ANc OTER CONSTRUCTION D-:.\?ar"5 M .\H AnPART OF THIS SE` THIS w€ETF 5 FOR DESIGN S= Nw :N.`AND NOT TO B ^E v —TE iN `n.�•�.�..• NOT U,.. THE r•`r` u O OF THE a,,, OJECT Cc DES-....., En THE e , N ,;^•�• �^;.,•+,N EN i i..?'kG.l�• AS COMPLETE,. PI:"tY M M+' lyi\ ;'F�.t'! '„�':\.Fi ec'T, BUT NECESSARY FOR , ;FED \dC.i�.�•:.a.: i�.•',I � THE i �\.•'::h..d t ; \ :.s:.. �.\..•�a:�' IN l..'�s:�t:1: Iii.\�.: i ;\t:F DOCUMENTS, SHALL BE THE : °t".c.�t.`.O3 'M'.IBILiTY OF THE CONTRACTOR. 2, ALL REMOVED LIGHTING AND ELECTRICAL CUTLET MING' SHALL BE ::MCN'T.«"+ �\. TO SOURCE, IN SR7.tT C RD NdE \• . ALL A:G 1:EMAL., %Elir:E AND . `ECA are, 'P; f r„ i 7w;„PONSE F ALL ji':`i. = E;'�7 ITCIRCUITRY, tom':' \d•"n";:v:: -; ..6%:I�t�a t`\�c7w m -a:.\ �i �:�a: \w �.-\. e...%N.. THE "r.,0.t't� . i\�. •, r.�. i � ..o�r,.l„.h, �..E.. r ..ice,¢{�"'• �t:.��.�a�, : ETC. \,-•..`'a.+;� \`.:.��, .� .r .. Taw... \✓� �w`.~b 1..•:�T.w E E 'tai'5,,, ErY.w ,,.-oh�,,Y;\vN NEIN fR �.�`.4Av:C.,,N OF ECSTIN„ aR.fALCUTLETS. 5. ft -MOVE ,.,.•Y EXISTING Fs4:,.• AN\'7, INCLUDING, CAfta-E , F�.` •\..•e,.• FLWRING. TE4..L; \b,sA`..+"E:.••. E7C, AS ?'GE'..1:+.R:..i••` .:..•';6 NWtN. i-iNISHa.S.:+53R:"A..•::: :O RECEIVE �r� FINISHES.THIS MAY N\tWVE~ C+Ri�~•�a �NDr ATClEN6 ,OF EASING �.�"�:, SLAB MUST BE SMOOTH AND LEVEL. ~. SE: ' -5 FOR "`N'w7 "7, 4, , ,�,N.,...k, Ae o � R 'SHALL R OVE ALLFIN€S w•" ANDARDS ELECTRICAL. ETC. DO1 N TO EMISI NC IN L. PATCH Yui . ; °P...Y Nw:` 1 G ` . A '•� k.•F.+:. � �+. �.. �+;\ ... �\t ,. �. .. � Ew FINISHES, ... , 7 ww• FY j`C THE a �_� w � _ ?`;,' BD. .. ALF'S ..A5 NECESSARY �~w Y�p. . et .vrE :N r;w "we "�"= a-5: A-4: Ae L+•.6Nv . `�.•,•: t; .a "RAc?oR5H4,1„ ��`3CVE ALL e\,1„.. kEiNc•�'=5~X?U \'::~_ CSEaINe , ELECTRICAL, ,RvE.R:; BU KCEk,',ST AtDWS.,Li(cH. I �T", i� :�_: !' @a= FITTINGy ROOMS ARO ST„...,7RAC-fi OOM AS RECZARED FOR NEA CONSTRUCTION AND FINISHES. wNTyH:LL k,...AND FLOOR SURFAC:E5 REMAINING FOR KEA ;, NSTRIX410N AND FINISH: , 4 e ONE (1) EXISTING R\wTRwTO.INN. INSPECT AND REPAIR FIXTURES AS mD TO MINE., TO A FI�G. :Av1W OPERATING CONDITION. VERIFY EXHAUST FAN OPERATION,�,” SIR AS N �. OLEAN ALL ZL AND FLOOR SUFSES. F ESR:�ATO RECEIVE EE. -5. 7. SPRINKLER H.G. SHALL BEft-LOCATED w R V < T; •S�7 , aT :ETima, SPRINKLER • �: +,�•� - i<"4yitNw-. C •'`�• r t -;'ik CONTACT MURICES 1 a. DIREOTION. CONTRA"YOwSMALL INSPECT THE CONDITION OF:64,, CSU CLaIIRM AND r p H""; ;6'\' "^�`EREMAINING. RE`s` �iR OR RE L t"E "O BRING . T i,f Fi `� T -6 ;`S K,.` `: N . :��. , . ��jq �,�y E aw ,� f-7 •P>.,,�\.E�.-,...�..�•. BRINE, `_ .:R� ` � �: "y`i�\'':.•:C. SEE Dck)0. . CH..W •;LE ON A-1 FOR RE •ARE•'' w7..X HARP ARE-•. 5' 10' RECEIVED CITY OF UK -T- - WiLA AUG 1 2 2013 PERMIT CENTER o 0 c� O U w J F-- Z OC U ce �.1-a cf)WW�U 'Ci (O U) 1— cc III 0 caw 0 0 O _c 2 U) O U) 0 ma) C J a) C) co co 7:1) a) O w F O r N w k z JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: DEMOLITION PLAN SHEET A-2 OF 22 SHEETS NON -SALES FINISH SCHEDULE ROOM FLOOR FINISH BASE FINISH NALL FINISH CEILING FINISH RESTROOM 'Y" 4 "Z" "U" "5" 4 T' "A" STOCK ROOM ,T,, "U" "A" EMPLOYEE REFRIGERATOR PROVIDED BY MAURICES CORRIDOR "1"' 4 "Z" 'U" "B" aq 1008.1.9.3 Locks and latches. Locks and latches shall be permitted to prevent operation of doors where any of the following exists: 1. Places of detention or restraint. 2. In buildings in occupancy Group A having an occupant load of 300 or less, Groups B, F, M and S, and in places of religious worship , the main exterior door or doors are permitted to be equipped with key -operated locking devices from the egress side provided: 2.1. The locking device is readily distinguishable as locked; 2.2. A readily visible durable sign is posted on the egress side on or adjacent to the door stating: THIS DOOR TO REMAIN UNLOCKED WHEN BUILDING IS OCCUPIED. The sign shall be in letters 1 inch (25 mm) high on a contrasting background; and 2.3. The use of the key -operated locking device is revocable by the building official for due cause. 3. Where egress doors are used in pairs, approved automatic flush bolts shall be permitted to be used, provided that the door leaf having the automatic flush bolts has no doorknob or surface -mounted hardware. 5. 5. Fire doors after the minimum elevated temperature has disabled the unlatching mechanism _ in accordance with_: listed fire door test procedures. 1008.1.9.4 Bolt locks. Manually operated flush bolts or surface bolts are not permitted. 150-01/2" OVERALL LEASE DIM. 2012 IBC MEANS OF EGRESS ILLUMINATION 1006.1 Illumination required. The means of egress, including the exit discharge, shall be illuminated at all times the building space served by the means of egress is occupied. 1006.2 Illumination level. The means of egress illumination level shall not be less than 1 foot-candle at the walking surface. 1006.3 Illumination emergency power. The power supply for means of egress illumination shall normally be provided by the premises' electrical supply. In the event of power supply failure, an emergency electrical system shall automatically illuminate the following areas: 1. Aisles and unenclosed stairways of rooms that require two or more means of egress. 2. Corridors, exit enclosures and exit passageways... 3. Exterior egress components... 4. Interior exit discharge elements... 5. Exterior landings...for exit discharge doorways... 2012 IBC MEANS OF EGRESS ILLUMINATION 1006.3.1 Illumination level under emergency power. Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle and a minimum at any point of 0.1 foot-candle measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle at the end of the emergency lighting time duration. A maximum -to - minimum illumination uniformity ration of 40 to 1 shall not be exceeded. NOTICE TO CONTRACTOR RETURN AIR PLENUM PROTECTION REQUIRED (This only applies to thos2.§2aces that share return air plenums) Before any mall Tenant space Improvements or alterations are to begin, where plenum ceilings are removed, altered or return air ceiling grills are open/exposed to construction dust contamination, a "plenum protection plan" shall be required to show procedures and methods for protecting and sealing the return air plenums of any contamination from construction dust and combustibles prior to and during construction work. No inspections shall be performed until mitigation procedures are made to protect any shared ceiling plenums. 15'-5" HOLD ±74'-61/2" ±1'-81/2" ADJACENT TENANT ±2-31/2" A Ai Arm- 14.v.‘"A Zfd"'"W7.-411‘42-7 4.142147,4KAA11/.17.4 1 "or /W. AW 4, l' .frOvArAr -AO'''. 4-eitt-L_ I siVER :NGERTIR rr I 0 �L�� 713 LEASE DIM. ADJACENT TENANT (N.I.C.) 12-2 5/4" LEASE DIM. v N 6 EXISTING MALL CONCOURSE (N.I.C.) m 0 w ofisi -31/2" NON -SALES AREA HOLD ±78'-g" 563 . USF ;LF Si;CARATE STORAGE RACK PERMIT RE UIRED All rack storage fixtures over 5'-9" high shall be installed under the provisions of a separate storage rack building permit. All rack storage fixtures greater than 8 -feet high shall have the method of anchorage/bracing i designed by a professional engineer. Periodic special inspection is required in all cases during the anchorage of racks over 8 -feet in height. Special inspection requirements shall be specified on the rack permit plan. 24'-0" 24'-0" 24'-0" 23'-q" ©p '4,1...00r N� SO ,c,� m.- m� I MK I BAGKSTOGK (MOVABLE) I- m 1- �q SEE 13/A-8 FOR ACCESSIBLE RESTROOM AND ACCESSORY INSTALLATION. 8 -31/2" NON -SALES AREA HOLD ±78'-g" 563 . USF ;LF Si;CARATE STORAGE RACK PERMIT RE UIRED All rack storage fixtures over 5'-9" high shall be installed under the provisions of a separate storage rack building permit. All rack storage fixtures greater than 8 -feet high shall have the method of anchorage/bracing i designed by a professional engineer. Periodic special inspection is required in all cases during the anchorage of racks over 8 -feet in height. Special inspection requirements shall be specified on the rack permit plan. 24'-0" 24'-0" 24'-0" 23'-q" ©p '4,1...00r N� SO INSTALL TYVO ROWS OF 12" PART. BD. SHELVES (4"-0" MAX LENGTHS) ON ALL NON -SALES WALLS., UNLESS NOTED OTHERWISE. INSTALL SHELVES AT 8'-6" AND 10-0" APF. 81 12" PART. BD. SHELVES IN AREA MARKED SHOE STORAGE AREA STARTING AT 18" AFF AT 18" O.G. UP TO g'-0" AFF. SHELVES ARE TO BE INSTALLED IN 4'-0" MAXIMUM LENGTHS. 52 PAINT STORE NAME IN 3" HIGH HELVETICA MEDIUM LETTERS AT 6'-0" A.F.F. PER MALL REQUIREMENTS 53 SEE 13/A-8 FOR ACCESSIBLE RESTROOM AND ACCESSORY INSTALLATION. 84 G.G. TO PROVIDE CLEAR MARKED AREA IN FRONT OF ELECTRICAL EQUIPMENT PER CODE WITH 3" RED TAPE 55 SEE 13/A -S FOR STANDARDS ABOVE TOILET 86 EMPLOYEE REFRIGERATOR PROVIDED BY MAURICES 87 N/A 55 EXISTING WATER HEATER ON SUSPENDED SHELF ABOVE RESTROOM CEILING. L.L. TO VERIFY CONDITION. REFER TO PLUMBING AND STRUCTURAL DRAWINGS FOR NEW WORK aq N/A q0 INSTALL FRP AND TRIM ON ALL RESTROOM WALLS. GENERAL NOTES: 1.) CONTRACTOR SHALL READ 4 REVIEW ALL SPECIFICATIONS AND PLANS, INCLUDING MECHANICAL AND ELECTRICAL. SEE TASK RESPONSIBILITY UST FOR INFORMATION ON ITEMS FURNISHED BY MAURICES. 2.) CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY MAURICES OF ANY DISCREPANCIES. 3.) SEE ELECTRICAL DETAILS FOR WIRING REQUIREMENTS FOR CASITY`IIRAP 4 BACKWRAP. 4.) CONTRACTOR TO SET EN PLACE AND JOIN SECTIONS OF CASHARAP AND BACKWRAP ON SITE. INSTALL AND SECURE TOPS. INSTRUCTIONS ARE INCLUDED VVNEW SECTIONS. CONTRACTOR TO INSTALL WOOD BASE, PROVIDED AiTH FIXTURES, AT TOE SPACES OF CA5HARA,P AND BACKARAP. ADJUST CASHVR.AP, BACKARAP N FIELD AS NECESSARY. 128'-41/4" OVERALL LEASE DIM. COL q 1 ELECTRIC HAND DRYER. SEE DETAIL 13/A-8 4 SPEC DIV 12q20. q2 N/A q3 "EMPLOYEES ONLY" SIGN INSTALLED e 5'-0" AFF CENTERED ON SALES SIDE OF DOOR *2 AND CORRIDOR SIDE OF DOOR 3 cI4INSTALL G.G. TO ASSEMBLE HANGER STORAGE SYSTEM AND TO WALL q5 NON -SALES MOVABLE STORAGE UNITS, TRACK AND CARRIERS. SEE DETAIL 12/A q6 SEE 11/A-7 FOR NUL_ BLOCKING. q7 PEG BOARD WIRE HOOK HOLDER. MOUNT YV TOP AT 65" A.F.F. qa MANAGER'S DESK qq BREAK TABLE AND MICROWAVE CABINET 100 HANGING PIPES (4) SEE DETAIL 11/A-8 56 MIN. 44" CLEAR PATH OF EGRESS PER STATE AND LOCAL\ CODES. REFER TO SHEET E-5 FOR EMERGENCY < ILLUMINATION 101 2. '► • 103 P05 EQUIPMENT PANEL. 6.0 TO COORDINATE INSTALL WITH FUJITSU. SEE ELECTRICAL DRAWINGS 104 SEE ELECTRICAL SHEETS FOR PANEL INFORMATION WALL HATCHING COL WALL STANDARD SCHEDULE LEGEND x FITTING ROOM KEYNOTES 2" GARMENT POLE HOOK AT 7-0" AFF. Ti? OF 4. 1 q 51 N/A G.G. TO RUN CASHWRAP WIRING AND CONDUITS WITHIN COLUMN ENCLOSURE. FRAME COLUMN TO DIMENSIONS SHOWN W/ METAL STUDS AND DRYWALL. TAPED, SANDED, PRIMED AND FINISHED "C" ABOVE AND BELOW MIRRORS, At 3-1/2" WOOD BASE FINISH "D". (TYP). 52 FITTING ROOM CHAIRS. FURNISHED AND INSTALLED BY MAURICES. 22 53 H.G. BENCH MOUNTED TO WALL. INSTALL CONDUIT AND WIRING IN COLUMN FOR CASHWRAP. SE E-2. 54 SIGN HOLDER, MOUNTED ON BACK OF DOOR o 5'-6" AFF TO CENTER OF HOLDER. TVP. ALL FITTING ROOM DOORS 32-50 55 SEE 14/A-7 FOR FITTING ROOM DOOR NAME PLATE 56 'LOVE -IT 4'LEAVE-IT HOOKS. SEE 2/A-6.1, 3/A-8 57 GARMENT HANG BARS. SEE 6/A-6.1, 4/A -S 58 FITTING ROOM DOOR BUMPER s i HANDICAP FITTING ROOM MIRROR. SEE DETAIL 2/A-8 60 HANDICAP FITTING ROOM ACCESSORIES. SEE DETAIL 12/A -S 61 SHIMMER SCREEN. INSTALL PER MANUFACTURERS SPECIFICATIONS AND DETAIL 5/A -S 62 2'X5' FITTING ROOM MIRROR. MOUNT 1'-0" AFF. TYP. FR NUMBERS 1-5.1-10. SEE 2/A -S FOR MOUNTING METHOD 55-11 N/A WALL STANDARD SCHEDULE LEGEND ADJACENT TENANT (N.LC.) 23 SALES FLOOR KEYNOTES © 2" GARMENT POLE HOOK AT 7-0" AFF. Ti? OF 4. 1 q G.G. TO FRAME COLUMN(5) TO SIZE SHOWN WITH METAL STUDS AND DRYWALL TAPED, SANDED, PRIMED AND FINISHED "G" ABOVE AND BELOW MIRRORS WITH 3-1/2" WOOD BASE "D" (TYP.). REFER TO DETAIL 14/A-8 20 G.G. TO RUN CASHWRAP WIRING AND CONDUITS WITHIN COLUMN ENCLOSURE. FRAME COLUMN TO DIMENSIONS SHOWN W/ METAL STUDS AND DRYWALL. TAPED, SANDED, PRIMED AND FINISHED "C" ABOVE AND BELOW MIRRORS, At 3-1/2" WOOD BASE FINISH "D". (TYP). 21 G.G. TO PROVIDE SMOOTH FINISHED SURFACE READY FOR FINAL FINISH. THIS MAY INCLUDING LAMINATING W/ i" GYP BD AS NEEDED. CONTACT MAURICES PROJECT MANAGER IMMEDIATELY FOR DIRECTION IF COLUMNS OR OTHER BUILDING ITEMS EXIST THAT WOULD PREVENT THE CONSTRUCTION AND FINISH OF A CONTINUOUS, FLUSH DEMISING WALL. 22 TVP. WALL STANDARDS SPACED 2'-0" O.G.. ALL SLOTTING MUST ALIGN AND BE LEVEL W/ TRADE NAME UPRIGHT. ADJACENT TENANT (N.LC.) 23 SEE SHEET E-2 FOR ELECTRICAL OUTLET PLACEMENT ALONG DEMISING WALLS. STANDARD LOCATIONS TAKE PRECEDENCE OVER ELECTRICAL OUTLET LOCATIONS. 24 2" GARMENT POLE HOOK AT 7-0" AFF. Ti? OF 4. 25 N/A 25 FLUSH -MOUNTED FLOOR OUTLET WITH COVER. SEE E-2 PLANS 4 SPECIFICATIONS. 27-25 N/A 2q CASITYRAP AND HOLD CLOSET FIXTURES FURNISHED BY MAURICE', INSTALLED BY G.G. SEE ELECTRICAL SHEETS FOR WIRING REQ'T5. 30 INSTALL CONDUIT AND WIRING IN COLUMN FOR CASHWRAP. SE E-2. 31 SLAB CUT FOR POWER. COORDINATE W/ LANDLORD. 32-50 WA FITTING ROOM LEGEND AND NOTES: © STOREFRONT KEYNOTES 1 NEW ALUMINUM STOREFRONT GLAZING SYSTEM. SEE A-5. 2 NEW CUSTOM WOOD DOORS FURNISHED BY MAURICES, INSTALLED BY G.G. 3 TILE FLOORING FINISH " X " AT SALES FLOOR. ORIENTATION NOTED ON PLAN 4 TILE FLOORING FINISH " W " AT ENTRY. ORIENTATION NOTED ON PLAN 5 LINE OF FLOOR FINISH TRANSITION 6 ADD MALL FLOORING IN STOREFRONT PORTAL FROM LEASE LINE TO CENTER LINE OF DOOR CLOSURE LINE AS NEEDED. COORDINATE W/ MALL MANAGER FOR CONTACT INFORMATION OF LOCAL INSTALLER. SEE 15/A-7 VNIRIN6 NOTES CDL S'-71/4" 1 LANDLORD TO EXTEND DEMISING WALL AND CAP AS INDICATED. REFER TO ENLARGED STOREFRONT PLAN 5/A-5 s- i N/A 10 FLOOR MOUNTED BOLT POCKETS (TYP. 4) REFER TO DOOR SCHEDULE ON A-1 11 FRE -OPENING BARRICADE SIGN. INSTALL FIRST WEEK ON JOB. 12 WALL -MOUNTED LIGHT BOX. SEE 2/A-6. INSTALL PER MANUFACTURERS SPECIFICATIONS 13-1q N/A 0 1' REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 5 2013 City of Tukwila BUILDING DIVISION 3' 5' 10' N U F- LU c\1 W Oo W W C- Z r Z 2 c9 = N W C0 J r - o CV - 0 r O U .c U) E N i L N rn 0 CLN 0 ^a W U 0 J C) co Co 2 0 0w O �• V) N z CO O d" at) (I) Q Las Itw_� Z CO W W = Q Z W Q (") Q J F- cor 0 O n JOB NO. 2170 DATE: 08-21-13 STORE TEAM: MC / MD -SS / CJ APPROVED BY : XX 2' 4' SCALE:' j4'. =1'-0" INDICATES EXISTING WALL. G.G. TO PATCH 4 REPAIR TO ACCEPT ANY NEW FINISHES. INDICATES NEW WALL TO ROOF DECK BY G.G. INDICATES NEW WALL TO 1" ABOVE CEILING BY G.G. INDICATES NEW DEMISING WALL AND CAP BY L.L. INDICATES NEW TOILET ROOM WALL BY L.L. WALL STANDARD SYMBOL o 2�.----- PREFINISHED COLOR (IF APPLICABLE) RB -RETIRING BLUE STANDARD HEIGHT (IN I-I±T) STANDARD TYPE LETTER DESIGNATION A - - SURFACE MOUNTED STANDARD ELEVATION NUMBER/ PAGE FOUND COLUMN BUBBLE DOOR NUMBER SEE SCHEDULE FITTING ROOM NUMBER FINISH SEE SCHEDULE SEE SHEET A -S FOR FITTING ROOM DETAILS LEGEND: (NOT TO SCALE) COAT HOOK DOOR BUMPER HANG BARS (STACKED) SEE DETAIL 4/A-8 A-4 (2) MIRROR 0 0 3 WAY MIRROR P1111NG ROOM CHAIR HANDICAPPED FITTING ROOM BENCH 1) HANDICAPPED FITTING ROOM TO HAVE 3' X 5' MIRROR AT 1'-0" A.F.F.. GARMENT HANG BARS MOUNTED AT 5'-S" A.F.F. 4 6'-0" A.F.F. AND (1)1-1/2" O.D. GRAB BARS MOUNTED AT 34" A.F.F.-- FITTING ROOM 5 GENERAL CONTRACTOR MUST HAVE P05 EQUIPMENT BOARD MOUNTED ON WALL FOR THE PHONE SERVICE WITHIN THE FIRST WEEK OF CONSTRUCTION. GENERAL CONTRACTOR SHALL FURNISH AND INSTALL A 66 PUNCH DOAN BLOCK FOR THE PHONE SERVICE ALONG WT4 ALL PHONE JACKS (AS SHOWN ON -E-4), WIRING, CONNECTIONS AND COVER PLATE.-- CAT LATES.-CAT 5 WIRE FROM POS EQUIPMENT PANEL TO CASHWRAP TO BE SUPPLIED AND INSTALLED BY Fujitsu. MAURICES PROJECT MANAGER WILL CONTACT TO ARRANGE FOR INSTALLATION 1 WEEK BEFORE THE STORE PUNCH DATE. CONTRACTOR MUST HAVE CASHARAP INSTALLED FOR WIRING INSTALLATION. GENERAL CONTRACTOR SHALL BE RESPONSIBLE TO HOOK-UP VPN EQUIPMENT (MODEM AND ROUTER) SUPPLIED BY MAURICES ON POS EQUIPMENT BOARD IN NON -SALES AREA. G.G. TO COORDINATE WITH SCOTT BRIGKLES AT MAURICE' AT 218-127-8451 EXT. 3151 OR MATT GERARD AT 218127-8451 EXT. 31'48 FOR INSTALLATION OF EQIUPMENT. RECEIVED CITY OF TUKWILA AUG 232013 PERMIT CENTER REVISIONS: REV *1 5-16-2013 DBS REV *2 8-21-2015 PBS CONSTRUCTION PLAN SHEET A-3 OF 23 SHEETS V 640" 1 K r 6'-01 H V ______ ::::.Ci..: -ICI :2 — RESTROOM CEILING PLAN 4'-6" Ox NON -SALES AREA KEYNOTES 40 NON -SALES OPEN TO DECK ABOVE 41 VANITY LIGHT. SEE DETAIL 13/A -S 42 (E) RESTROOM EXHAUST FAN. REFER TO MECHANICAL DRAWINGS FOR NEW WORK. LL. TO VERIFY WORKING CONDITION 43-44 N/A 45 HANGING PIPES (4) AT 12'-0" A.F.F. SEE 11/A -S 46 FI..UORESCENT STRIP FIXTURES ON CHAIN SUPPORTS AT 12-6" A.F.F. 41 (E) GYP. BD. CEILING. L.L. TO RE -FINISH PER SCHEDULE 45 REAR DOOR BUZZER ANNUNCIATOR ON WALL AT 11'-0" A.F.F. 4.21 REAR DOOR BUZZER SWITCH AT 5'-0" A.F.F. REFER TO ELECTRICAL DRAWINGS 50 NON -SALES ENTRY ALERT CHIME (1) 4 WIRELESS RECEIVERS (2) FURNISHED BY MAURICES. G.G. TO INSTALL CHIME 4 ONE RECEIVER ® NON -SALES DOOR 4 ONE RECEIVER ON COLUMN NEXT TO HOLD CLOSET IN SALES AREA. G.G. TO SET TRANSMITTER TO "CHIME" W/ "DING DONG" TONE 4 SET RECEIVERS VOLUME TO MEDIUM. (X) SALES AREA KEYNOTES 20 NEW 2x4 ACOUSTICAL TILE GRID SYSTEM BY G.G. AT 11'-0" A.F.F. REFER TO SPECIFICATIONS DIVISION 09500 21 CEILING GRID ORIGIN. CEILING TO HAVE EQUAL SPACES ALONG EACH DEMISING WALL 22 SEE DETAIL 3/A-4 FOR TYPICAL SPACING OF "CC" LIGHT FIXTURE HEIGHTS 23 CEILING -MOUNTED ELECTRICAL RECEPTACLE. REFER TO ELECTRICAL DRAWINGS 24 ALL TRACK TO BE MOUNTED 4'-3" FROM WALL UNLESS OTHERWISE NOTED 25 SHIMMER SCREEN. SEE DETAIL 5/A -S 26 PENDANT LIGHT FIXTURE, SEE ELEVATION 2/A-4 FOR MOUNTING HEIGHT. 21 START WITH 1 FULL TILE AT CENTER OF FITTING ROOM AND LOCATE EQUAL CUT TILES AS INDICATED. TYP. ALL FITTING ROOMS 28 REAR DOOR BUZZER ANNUNCIATOR ABOVE CEILING TILE 2q FITTING ROOM DOOR HEADER / SOFFIT 30-3q N/A i OAM-U i111111.11111 O� 4'-1 1/2" 9 0 IA _O u O 0 U O U 1A REFER TO REFLECTED REFLECTED CEILING PLAN REFER TO DETAIL 2/A-4 FOR PENDANT LIGHT(S) MOUNTING HEIGHTS TYPICAL PENDANT FIXTURE SPACING SCALE: 1/2" =1-0" U 0 U O rt U iO A-30' A124' M M M M M M M M I It M 3'-4 1/2" Xi/ 1'-113/4" A-4' .a i 0 A-4' 0 OHO A-4' 0 0 \ A-4' O OI O 4'-q 1/4" ■..■ Cru SIMS SEES ■.a■ Saar SNUB au■ a... a Ea■ U••• 152•111 SUE■ ■■U■ 1111.. ■aa■ ■aa. SSSSUSSR B M 110 ... MEM IMP 32'-113/4" '-1 3/4" I 1'112 3/4" 2'-0" -1-61+.1-1H+I+H±1-4±H *+H+FH+FI+H-H+H-1-1+1--Ice---------.-------,— I' W ±2-10 1/4" m 0 Ul -1-1(9-444 H-1444-1+ I4 H+H H+1-F+i H++FH+H-H-H_ - i J Q aK o 1 Oimumw 1 1 ri. mi Bop 0 0 speol 0 I 0 A� I ,o �!I ik v •gyNur m ��N u__ F TYP. TYP. • OPEN TO STRUCTURE W LI III 0 �F U TYP. '8 I O 1$ (417 • 444A 4'3" M M M M M M M 3' 11 5/4" IA 0 U IA II I" CC CCG 1 1 COL TYP. A-4' B B B 4 1 6 A-4' B B B COL ASA 1 0 ACT CEILING A-4' B BB A-4' 0 t. 4'-0" T1CP. CC 14 ■IES ... RUM M. a... ■..■ MIME tea... a... uu MERE MIME a•..■ ■u■ MM. •••• ■M.■ 11.15. aar■ ■aa■ MUSE au■ a... a... SEEM ...E ■.a■ Eu■ ..E■ a... ■U.. ■EE■ ■..■ a..■ a..■ LI:: ■ .EEE (pp a. a. Ani ■■ •• WO/ .. sal .. um ■■ ■■ ■■ Jim .. .. .. .. .. U 4'-13/5" 0 1' 5' LIV 5' 10' 2' 4' SCALE: %4' =1'-0" 1 STOREFRONT KEYNOTES 1 SIGN OUTLET IN BULKHEAD FOR STOREFRONT SIGN. REFER TO ELECTRICAL DRAWINGS FOR NEW WORK 2 BOTTOM OF BULKHEAD AT 10'-11" A.F.F. REFER TO SECTION 1/A-5.1 3 BOTTOM ON NEW ENTRY SOFFIT AT 10'-2" A.F.F. REFER TO PLAN AND ELEVATIONS ON SHEET A-5 FOR FINISHES 4 BOTTOM OF DISPLAY WINDOW SOFIT AT 12'-0" A.F.F. 5 60" SIGN GRID (TYP. OF 6) SEE 1/A -S. 6 60" SIGN GRID CUT TO 6" WIDTH (TYP. OF 6) SEE 1/A -S 1 STOREFRONT LIGHT FIXTURES DIMENSIONS (TYP.) S BOTTOM OF DOOR OPENING AT q' -S" A.F.F. REFER TO SECTION 3/A-5.1 q -1q N/A i OAM-U i111111.11111 O� 4'-1 1/2" 9 0 IA _O u O 0 U O U 1A REFER TO REFLECTED REFLECTED CEILING PLAN REFER TO DETAIL 2/A-4 FOR PENDANT LIGHT(S) MOUNTING HEIGHTS TYPICAL PENDANT FIXTURE SPACING SCALE: 1/2" =1-0" U 0 U O rt U iO A-30' A124' M M M M M M M M I It M 3'-4 1/2" Xi/ 1'-113/4" A-4' .a i 0 A-4' 0 OHO A-4' 0 0 \ A-4' O OI O 4'-q 1/4" ■..■ Cru SIMS SEES ■.a■ Saar SNUB au■ a... a Ea■ U••• 152•111 SUE■ ■■U■ 1111.. ■aa■ ■aa. SSSSUSSR B M 110 ... MEM IMP 32'-113/4" '-1 3/4" I 1'112 3/4" 2'-0" -1-61+.1-1H+I+H±1-4±H *+H+FH+FI+H-H+H-1-1+1--Ice---------.-------,— I' W ±2-10 1/4" m 0 Ul -1-1(9-444 H-1444-1+ I4 H+H H+1-F+i H++FH+H-H-H_ - i J Q aK o 1 Oimumw 1 1 ri. mi Bop 0 0 speol 0 I 0 A� I ,o �!I ik v •gyNur m ��N u__ F TYP. TYP. • OPEN TO STRUCTURE W LI III 0 �F U TYP. '8 I O 1$ (417 • 444A 4'3" M M M M M M M 3' 11 5/4" IA 0 U IA II I" CC CCG 1 1 COL TYP. A-4' B B B 4 1 6 A-4' B B B COL ASA 1 0 ACT CEILING A-4' B BB A-4' 0 t. 4'-0" T1CP. CC 14 ■IES ... RUM M. a... ■..■ MIME tea... a... uu MERE MIME a•..■ ■u■ MM. •••• ■M.■ 11.15. aar■ ■aa■ MUSE au■ a... a... SEEM ...E ■.a■ Eu■ ..E■ a... ■U.. ■EE■ ■..■ a..■ a..■ LI:: ■ .EEE (pp a. a. Ani ■■ •• WO/ .. sal .. um ■■ ■■ ■■ Jim .. .. .. .. .. U 4'-13/5" 0 1' 5' LIV 5' 10' 2' 4' SCALE: %4' =1'-0" 1 • III . b TYP W p TYP Ii 0 � • ■■ a. a. S. SS ■■ ■■ EN .111111' ME UN c_ ME ME ES ■■ ■■ ■■ ME as INE .a ■..■ X11.' Q 1 2-1 1/2" 2-2 1/4" 0 to ni NON -SALES FITTING ROOMS AREA SALM TYPICAL LIGHT FIXTURE MOUNTING HEIGHTS GENERAL NOTES: LEGEND €(;)_ REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 5 2013 City of Tukwila BUILDING DIVISION b ..)...(90 LU (NI 2 c9 hir 00 0 wo ttce 00 0 Ur CO LLI Lei CO 0 cn cn P. co co a) 0 cn ca ca 0 Lit CNI CO at) o la= ft 00 wiiimj [LI < ES JOB NO. 2170 DATE: 08-21-13 STORE TEAM: MC I MD -SS / CJ APPROVED BY : XX REVISIONS: REV it1 5-16-2013 DBS REV #2 5-21-2015 OBS 1) CONTRACTOR SHALL READ AND REVIEW ALL SPECIFICATIONS AND PLANS, INCLUDING MECHANICAL AND ELECTRICAL. SEE TASK RESPONSIBILITY LIST FOR INFORMATION ON ITEMS FURNISHED BY MAURICES. 2) CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND NOTIFY MAURICES OF ANY DISCREPANCIES. 3) FIELD VERIFY ASSEMBLY REGJIREMENTS FOR CASHIAIRAP TO DETERMINE NECESSARY CORD LENGTHS FOR CASH WRAP WIRING. 4) CONTRACTOR TO RAISE AND / OR RELOCATE EXISTING SPRINKLER HEADS AS REQUIRED FOR NEW LIGHT LOCATIONS. LIGHT FIXTURE LOCATIONS TAKE PRECEDENCE OVER ALL OTHER CEILING EQUIPMENT. SEE ELECTRICAL DRAWINGS. COORDINATE WITH LANDLORD. 5) SEE ELECTRICAL DETAILS FOR ALL WIRNG LAYOUTS. 6) ALL FIXTURES TO HAVE LAMPS AS SPECIFIED AND SUPPLIED 13Y MAURICES. ELECTRICAL CONTRACTOR SHALL PROVIDE ALL HARDWARE, ACCESSORIES, ETC., NECESSARY FOR INITIAL INSTALLATION. 1) CONTRACTOR TO PROVIDE ALL SUPPORT FRAMING, ALL THREAD AND UNISTRUT MAL STRUCTURAL SYSTEMS TO HANG FIXTURES, CEILING TRANSITIONS, CEILING SYSTEM, ETC. FROM MALL STRUCTURE NT -LT 1X4 FLUORESCENT TROFFER 2X4 FLUORESCENT TROFFER 2X4 FLUORESCENT TROFFER NIGHT LIGHT 2X4 FLUORESCENT TROFFER EMERG. BALLAST 2X2 FLUORESCENT TROFFER 2X2 FLUORESCENT TROFFER N/ NERO. BALLAST DOUBLE TUBE FLUORESCENT STRIP ' SINGLE TUBE FLUORESCENT STRIP SINGLE TUBE FLUORESC5NT STRIP TRACK MOUNT METAL HALIDE LIGHT FIXTURE RESTROOM VANITY LIGHT EXTERIOR LIGHT LIGHT TRACK ei/ TRACK HEADS WALL -MOUNT EMERGENCY LIGHT EXIT LIGHT PENDANT MOUNT FIXTURE EXHAUST FAN TRANSFORMER 1‘11 ELEC. PANEL INCTION BOX BIZZER SNITCH 60" AFF BUZZER ANNUNCIATOR 0 CONCEALED SIGN OUTLET (I) ORIGIN POINT DOOR CHIME SYST54 NON -SALES DOOR CHIME SYSTEM RECEIVED CITY OF TUKWILA AUG 2 3 2013 PERMIT CENTER REFLECTED CEILING PLAN SHEET A-4 23 SHEEly NOTE: CONTRACTOR SHALL APPLY DUROPLEX FINISH "G" TO STOREFRONT A5 SHOWN. CONTRACTOR SHALL PAINT OVER THE FINISHED DUROPLEX WITH FINISH "F" B.O. (E) MALL GEILIN ±12-1 1/4" GLAZING 40'-0" t12-1 1/4" GLAZING ul 1 ul -71 REFER TO CONSTRUCTION PLAN A-3 iu w J Z r +011 ±12-1 1/4" GLAZING OM - GLAZING - EXIT n- 0 I EQ. EQ. TYP. EQ. t12'-1 1/4" GLAZING Q STOREFRONT ELEVATION - EXTERIOR SCALE: 1/4" =1'-0" STOREFRONT ELEVATION - INTERIOR SCALE: 1/4" =1'-0" (E) TENANT DEMISING WALL. G.G. TO PROTECT DURING CONSTRUCTION. PATCH AND REPAIR TO LIKE -NEW CONDITION — LAYOUT Ac LAYOUT POINT POINT 1'-2" NOTE: CONTRACTOR SHALL APPLY DUROPLEX FINISH "G" TO STOREFRONT A5 SHOWN. CONTRACTOR SHALL PAINT OVER THE FINISHED DUROPLEX WITH FINISH "F" FLOOR -MOUNTED BOLT POCKETS (TYP. 4) O N LINE OF ENTRY SOFFIT ±11'-1 1/4" ALL SIDES WITH WOOD BASE STOREFRONT SOFFIT AT 12-0". REFER TO SECTION 1/A-5.1 4 3/4" 4 7/8" 3'-0" �_ HOLD ±11-5' GLAZING 5" 6'-0" HOLD ?Ni ±1'-5" GLAZING 4 3/4" 4 7/8" k. 3'-0" HOLD NEW BUILT-UP BOX COLUMN(S) (TYP OF ALL). REFER TO STOREFRONT DETAILS ON A-5 AND STRUCTURAL DRAWINGS (TYP.) ±10'-71/4" STOREFRONT SOFFIT ALL SIDES WITH AT 12'-0". REFER TO WOOD BASE SECTION 1/A-5.1 (E) MALL NEUTRAL PIER. G.G. TO PROTECT DURING CONSTRUCTION. PATCH AND REPAIR TO LIKE -NEW CONDITION LEASE LINE DISPLAY WALL BULKHEAD AT 10'-5" A.F.F. REFER TO SECTION 1/A-5.1 © ALUMINUM TRIM AT 11'-3". REFER TO SECTION 1/A-5.1 4 DISPLAY WALL BULKHEAD AT 10'-5" A.F.F. REFER TO SECTION 1/A-5.1 r N N ALUMINUM TRIM AT 11'-3". REFER TO SECTION 1/A-5.1 9 GLAZING . GLAZING 5/8" TEMPERED STOREFRONT GLAZING 6" ALUMINUM BASE ±12-1 1/4" GLAZING ENTRY SOFFIT AT 10'-2". REFER TO SECTION 3/A-5.1 10'-51/2" 5/8" TEMPERED STOREFRONT GLAZING 6" ALUMINUM BASE ±12-1 1/4" GLAZING 401-0" GLAZING Cr. OVERALL LEASE DIMENSION (E) TENANT DEMISING WALL. G.G. TO PROTECT DURING CONSTRUCTION. PATCH AND REPAIR TO LIKE -NEW CONDITION (E) MALL NEUTRAL PIER. G.G. TO PROTECT DURING CONSTRUCTION. PATCH AND REPAIR TO LIKE -NEW CONDITION LEASE LINE GENERAL NOTES: 1. REFER TO STRUCTURAL DRAWINGS FOR ALL MEMBER SIZES, CONNECTION DETAILS, AND CONSTRUCTION NOTES FOR BUILD -OUT. 2. murices G.G. SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN THE STRUCTURAL INTEGRITY OF THE EXISTING BUILDING. 3. murices G.G. SHALL BE RESPONSIBLE FOR RECONSTRUCTING AND REPAIRING ANY DAMAGE TO THE BUILDING'S ROOFING SYSTEM DUE TO THIS CONSTRUCTION. 4. ALL PENETRATIONS THROUGH AND CONNECTIONS TO EXISTING STRUCTURE SHALL BE MADE WATER -TIGHT WITH FLASHING, CAULKING, RUBBER MEMBRANES, OR OTHER EFFECTIVE, COMMONLY ACCEPTED METHOD CONSISTENT WITH ALL EXISTING MATERIALS. 5. ANY RE -CONSTRUCTION / PATCHING SHALL BE OF SIMILAR CONSTRUCTION AND BE INDISTINGUISHABLE FROM ADJACENT SURFACES. 6. REPLACE ANY MATERIAL REMOVED FOR CONSTRUCTION, PATCHING AROUND PENETRATIONS TO PROVIDE A COMPLETE, CONTINUOUS ROOF. 7. SIGN INSTALLER TO INSPECT SIGN IMMEDIATELY UPON ARRIVAL AT THEIR SHOP AND NOTIFY SIGN VENDOR IF ANY DAMAGE HAS OCCURRED DURING SHIPPING. S. PRE -OPENING BARRICADE SIGN FURNISHED BY maurices' VENDOR. G.G. TO INSTALL FIRST WEEK ON THE JOB. SEE INSTALLATION INSTRUCTIONS W/ PACKAGING. © STOREFRONT KEYNOTES 1 NEW 14" STOREFRONT SIGN. BEE S/A-S 2 NEV( STOREFRONT DOUBLE DOORS AND HARDWARE, FURNISHED BY MAURICES, INSTALLED BY G.G. G.G. TO PRIME AND PAINT FINISH "F". SEE FINISH SCHEDULE ON A-1 3 NEW 3/4" BLACK REVEAL AROUND STOREFRONT 4 6" ALUMINUM BASE 5 fr / 6 / / .► il MALL NEUTRAL BAND 5-12 0 \ \ I® . )I / I I Ij I I I I I I I I I 11 6" ALUMINUM TRIM AROUND WINDOWS 15 4" ALUMINUM TRIM AROUND DOORS 1-i-24 N/A ±V-5" 0 ©O 6'-0 ±1-5" GLAZIN GLAZING 10'-5 1/2" n- 0 I EQ. EQ. TYP. EQ. t12'-1 1/4" GLAZING Q STOREFRONT ELEVATION - EXTERIOR SCALE: 1/4" =1'-0" STOREFRONT ELEVATION - INTERIOR SCALE: 1/4" =1'-0" (E) TENANT DEMISING WALL. G.G. TO PROTECT DURING CONSTRUCTION. PATCH AND REPAIR TO LIKE -NEW CONDITION — LAYOUT Ac LAYOUT POINT POINT 1'-2" NOTE: CONTRACTOR SHALL APPLY DUROPLEX FINISH "G" TO STOREFRONT A5 SHOWN. CONTRACTOR SHALL PAINT OVER THE FINISHED DUROPLEX WITH FINISH "F" FLOOR -MOUNTED BOLT POCKETS (TYP. 4) O N LINE OF ENTRY SOFFIT ±11'-1 1/4" ALL SIDES WITH WOOD BASE STOREFRONT SOFFIT AT 12-0". REFER TO SECTION 1/A-5.1 4 3/4" 4 7/8" 3'-0" �_ HOLD ±11-5' GLAZING 5" 6'-0" HOLD ?Ni ±1'-5" GLAZING 4 3/4" 4 7/8" k. 3'-0" HOLD NEW BUILT-UP BOX COLUMN(S) (TYP OF ALL). REFER TO STOREFRONT DETAILS ON A-5 AND STRUCTURAL DRAWINGS (TYP.) ±10'-71/4" STOREFRONT SOFFIT ALL SIDES WITH AT 12'-0". REFER TO WOOD BASE SECTION 1/A-5.1 (E) MALL NEUTRAL PIER. G.G. TO PROTECT DURING CONSTRUCTION. PATCH AND REPAIR TO LIKE -NEW CONDITION LEASE LINE DISPLAY WALL BULKHEAD AT 10'-5" A.F.F. REFER TO SECTION 1/A-5.1 © ALUMINUM TRIM AT 11'-3". REFER TO SECTION 1/A-5.1 4 DISPLAY WALL BULKHEAD AT 10'-5" A.F.F. REFER TO SECTION 1/A-5.1 r N N ALUMINUM TRIM AT 11'-3". REFER TO SECTION 1/A-5.1 9 GLAZING . GLAZING 5/8" TEMPERED STOREFRONT GLAZING 6" ALUMINUM BASE ±12-1 1/4" GLAZING ENTRY SOFFIT AT 10'-2". REFER TO SECTION 3/A-5.1 10'-51/2" 5/8" TEMPERED STOREFRONT GLAZING 6" ALUMINUM BASE ±12-1 1/4" GLAZING 401-0" GLAZING Cr. OVERALL LEASE DIMENSION (E) TENANT DEMISING WALL. G.G. TO PROTECT DURING CONSTRUCTION. PATCH AND REPAIR TO LIKE -NEW CONDITION (E) MALL NEUTRAL PIER. G.G. TO PROTECT DURING CONSTRUCTION. PATCH AND REPAIR TO LIKE -NEW CONDITION LEASE LINE GENERAL NOTES: 1. REFER TO STRUCTURAL DRAWINGS FOR ALL MEMBER SIZES, CONNECTION DETAILS, AND CONSTRUCTION NOTES FOR BUILD -OUT. 2. murices G.G. SHALL TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN THE STRUCTURAL INTEGRITY OF THE EXISTING BUILDING. 3. murices G.G. SHALL BE RESPONSIBLE FOR RECONSTRUCTING AND REPAIRING ANY DAMAGE TO THE BUILDING'S ROOFING SYSTEM DUE TO THIS CONSTRUCTION. 4. ALL PENETRATIONS THROUGH AND CONNECTIONS TO EXISTING STRUCTURE SHALL BE MADE WATER -TIGHT WITH FLASHING, CAULKING, RUBBER MEMBRANES, OR OTHER EFFECTIVE, COMMONLY ACCEPTED METHOD CONSISTENT WITH ALL EXISTING MATERIALS. 5. ANY RE -CONSTRUCTION / PATCHING SHALL BE OF SIMILAR CONSTRUCTION AND BE INDISTINGUISHABLE FROM ADJACENT SURFACES. 6. REPLACE ANY MATERIAL REMOVED FOR CONSTRUCTION, PATCHING AROUND PENETRATIONS TO PROVIDE A COMPLETE, CONTINUOUS ROOF. 7. SIGN INSTALLER TO INSPECT SIGN IMMEDIATELY UPON ARRIVAL AT THEIR SHOP AND NOTIFY SIGN VENDOR IF ANY DAMAGE HAS OCCURRED DURING SHIPPING. S. PRE -OPENING BARRICADE SIGN FURNISHED BY maurices' VENDOR. G.G. TO INSTALL FIRST WEEK ON THE JOB. SEE INSTALLATION INSTRUCTIONS W/ PACKAGING. © STOREFRONT KEYNOTES 1 NEW 14" STOREFRONT SIGN. BEE S/A-S 2 NEV( STOREFRONT DOUBLE DOORS AND HARDWARE, FURNISHED BY MAURICES, INSTALLED BY G.G. G.G. TO PRIME AND PAINT FINISH "F". SEE FINISH SCHEDULE ON A-1 3 NEW 3/4" BLACK REVEAL AROUND STOREFRONT 4 6" ALUMINUM BASE 5 NEV( STOREFRONT GLAZING SYSTEM 6 TENANT G.G. TO FINISH DEMISING WALL AND CAPS IN GYP. BD. COMPLETE WITH 3/4" U -CHANNEL UP TO UNDERSIDE OF LIGHT COVE. COORDINATE FINISHES AND INSTALL WITH OPERATIONS MANAGER ONSITE. 7 MALL NEUTRAL BAND 5-12 N/A 13 G.G. TO PROVIDE GLASS CLIPS IF REQUIRED. INSTALL PER MANUFACTURERS SPECIFICATIONS 14-16 N/A 11 6" ALUMINUM TRIM AROUND WINDOWS 15 4" ALUMINUM TRIM AROUND DOORS 1-i-24 N/A N W O ce LO Lo LY_ � Oo W w 0-Z ZM UJ D W J v - Dr F:614.545A555 E 0 0 0 2 U) U) 5 a) 0 0 a a) U) a cI rn 2 0 a) 'o 0 ENLARGED STOREFRONT PLAN SCALE: 1/2" =1'-0" (E) TENANT DEMISING WALL. G.G. TO PROTECT DURING CONSTRUCTION. PATCH AND REPAIR TO LIKE -NEW CONDITION LEASE LINE (E) NEUTRAL PIER. G.G. TO PROTECT DURING CONSTRUCTION. PATCH AND REPAIR TO LIKE -NEW CONDITION 6" ALUMINUM BASE PROVIDED BY G.G. FINISH TO MATCH ADJACENT STYLMARK TRIM AND GLAZING BASE. REFER TO ELEVATION 1/A-5 J 1'-4 7/8" BUILT-UP BOX COLUMN(5). REFER TO STRUCTURAL DRAWINGS (TYP. ALL) LINE OF SOFFIT ABOVE. REFER TO REFLECTED CEILING PLAN A-4 5/8" GYP. BD. OVER METAL STUD FRAMING (TYP.) TO RECEIVE FINISH "C" ON ALL. SIDES WITH 3-1/2" WOOD BASE.REFER TO STRUCTURAL DRAWINGS. STYLMARK TRIM PROVIDED BY G.G. REFER TO ELEVATION 1/A-5 NEW STYLMARK STOREFRONT SYSTEM PROVIDED BY G.G. REFER TO SECTION 1/A-5.1 5/8" TEMPERED GLAZING BULKHEAD ABOVE. REFER TO REFLECTED CEILING PLAN A-4 LEASE LINE BUILT-UP BOX COLUMN(5). REFER TO STRUCTURAL DRAWINGS (TYP. ALL) 5/8" GYP. BD. OVER METAL STUD FRAMING (TYP.) REFER TO STRUCTURAL DRAWINGS. STOREFRONT PIERS TO RECEIVE FINISH "G/F" ON ALL SIDES WITH 6" ALUMINUM BASE. 6" STYLMARK TRIM PROVIDED BY G.G. REFER TO ELEVATION 1/A-5 HEADER ABOVE. REFER TO REFLECTED CEILING PLAN A-4 NEW STYLMARK STOREFRONT SYSTEM PROVIDED BY G.G. REFER TO SECTION 2/A-5.1 5/8" TEMPERED GLAZING r 1/4' REFER TO ENLARGED PLAN 3/A-5 4" ±1-5" 3/4" GLAZING 2-2 3/4" J REFER TO ENLARGED 11.1/4" PLAN 3/A-5 BUILT-UP BOX COLUMN. REFER TO STRUCTURAL DRAWINGS (TYP. ALL) LINE OF SOFFIT ABOVE. REFER TO REFLECTED CEILING PLAN ALUMINUM BREAK METAL TO MATCH ADJACENT GLAZING FRAME (TYP.) HEADER ABOVE. REFER TO SECTION 1/A-5.1 STYLMARK TRIM PROVIDED BY G.G. REFER TO ELEVATION 1/A-5 AND DETAIL 4/A-5.1 STOREFRONT WOOD DOOR. REFER TO DOOR SCHEDULE ON A-1 FLOOR MOUNTED BOLT POCKETS (TYP. OF 4 EACH DOOR). REFER TO DOOR SCHEDULE ON A-1 LEASE LINE REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 5 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 0 2 2013 PERMIT CENTER O w Ce F 0 T N w z CO O ass) U) J J Q � Q w oo Dctw O w WuS E I- O O CO C CO JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: ENLARGED STOREFRONT PLAN AND ELEVATIONS STOREFRONT DETAIL SCALE: 1" =1'-0" STOREFRONT DETAIL SCALE: 1" =1'-0" SHEET A-5 K7.IF__) 22 SHEETS GYP. BP. TO EXTEND 6" ABOVE NEW CEILING 12'-0" A.F.F. B.O. ACT CEILING NOTE GENERAL CONTRACTOR TO SUPPORT AND BRACE BULKHEADS A5 REQUIRED. STOREFRONT SYSTEM MUST BE SELF-SUPPORTING AND INDEPENDENT FROM MALL BULKHEAD - TENANT MAY USE BULKHEAD FOR LATERAL SUPPORT ONLY EXISTING MALL BULKHEAD FRAMING AND FINISHES TO REMAIN (N.I.G.). G.G. TO PROTECT DURING CONSTRUCTION 10'-5" A.F.F. B.O. BULKHEAD TENANT SPACE ±15-6" A.F.F. (E) MALL CEILING ±14'-0" A.F.F. B.O. (E) MALL BULKHEAD BUILT-UP BOX BEAM. REFER TO STRUCTURAL DRAWINGS 12-0" A.F.F. B.D. DISPLAY WINDOW SOFFIT 11'-3" A.F.F. T.O. GLAZING 4 1/8" 41/8"J 3 1/8" REFER. TO CEILING PLAN A-4 HEAD 5/8" TYPE "X' GYP. BD. OVER METAL STUD FRAMING. (TYP) REFER TO STRUCTURAL DRAWINGS 5/8" TEMPERED GLASS MALL CONCOURSE LEASE LINE 1 , !-/7/ /// BASE 0'-0" (E) MALL FLOOR 4 4 4 4 BUILT-UP BOX BEAM(S). REFER TO STRUCTURAL DRAWINGS NOTE: GENERAL CONTRACTOR TO SUPPORT AND BRACE BULKHEADS AS REQUIRED. STOREFRONT SYSTEM MUST BE SELF-SUPPORTING AND INDEPENDENT FROM MALL BULKHEAD - TENANT MAY USE BULKHEAD FOR LATERAL SUPPORT ONLY GYP. BD. TO EXTEND 6" ABOVE NEIN CEILING13, --- . - 12-0" A.F.F. B.O. ACT CEILING TENANT SPACE HEAD :I . •±. \I .I a � •1 / / I• ,.. i I I' I I I� / / / / / : / / / / r1 P I; --f •.I /•N 7--1-- —..IS ► .` ' - A T-1" - 3'-2" 4 1/8"--)31/8"-. 4'-1 '1/5, REFER `O CEILING PLAN A-4 EXISTING MALL BULKHEAD FRAMING AND FINISHES TO REMAIN (N.I.G). G.G. TO PROTECT DURING CONSTRUCTION ±15-6" A.F.F. (E) MALL CEILING ±14'-0" A.F.F. B.O. (E) MALL BULKHEAD 10'-2" A.F.F. 7 B.O. ENTRY SOFFIT 1'-8" A.F.F. T.O. GLAZING 5/8" TYPE "X" GYP. BD. OVER METAL STUD FRAMING. REFER TO STRUCTURAL DRAWINGS (TYP.) %5/A6%//' //// / 4 4 RECESSED DOWN LIGHT. REFER TO REFLECTED CEILING PLAN A-4 5/8" TEMPERED GLASS MALL CONCOURSE LEASE LINE 6" ALUMINUM BASE BEYOND. FINISH TO MATCH ADJACENT STYLMARK GLAZING FRAME REFER TO DETAIL 3/A-5.1 0'-0" (E) MALL FLOOR 4 4 4 BUILT-UP BOX BEAM(S). REFER TO STRUCTURAL DRAWINGS GYP. BD. TO EXTEND 6" ABOVE NEV( CEILING12-0" A.F.F. 11 B.O. ACT CEILING TENANT SPACE NOTE: GENERAL CONTRACTOR TO SUPPORT AND BRACE BULKHEADS AS REQUIRED. STOREFRONT SYSTEM MUST BE SELF-SUPPORTING AND INDEPENDENT FROM MALL BULKHEAD - TENANT MAY USE BULKHEAD FOR LATERAL SUPPORT ONLY ""u mu G :r. •L' I• / / / / / 1 —1 HEAD 4'-11/8" 3'-2" / 3 1/8" CEILING PLAN A-4 ///////// ////// // / EXISTING MALL BULKHEAD FRAMING AND FINISHES TO REMAIN (N.I.C.). G.G. TO PROTECT DURING CONSTRUCTION ±15'-6" A.F.F. (E) MALL CEILING ±14'-0" A.F.F. B.O. (E) MALL BULKHEAD NEW 14" TENANT SIGNAGE. REFER TO DETAIL 8/A-8 101-2" A.F.F. 7 B.O. ENTRY SOFFIT 1'-8" A.F.F. T.O. DOOR OPENING 5/8"" TYPE 'X' GYP. BD. OVER. METAL STUD FRAMING. REFER TO STRUCTURAL DRAWINGS {TYP.) RECESSED DOWN LIGHT. REFER TO REFLECTED CEILING PLAN A-4 MALL CONCOURSE LEASE LINE 6" ALUMINUM BASE BEYOND. FINISH TO MATCH ADJACENT STYLMARK GLAZING FRAME. REFER TO DETAIL 3/A-5.1 0'-0" 4 4 4 4 (E) MALL FLOOR 4 W CV (/) Er9 Wo Q '- o 0 kid W W aZ ZM (1) .4c°rE W 3 co DCJ STOREFRONT SECTION SCALE: 1/2" =1'-0" STOREFRONT SECTION SCALE: 1/2" =1'-0" STOREFRONT SECTION SCALE: 1/2" = 1'-0" • • • #110261 6" TRIM #412002 BACK PLATE G.G. TO PROVIDE CONTINUOUS FRT BLOCKING FOR TRIM ATTACHMENT #410540 BACK PLATE #110226 TRIM LEASE LINE 5/8" GYP. BD. OVER METAL STUD FRAMING (TYP.) REFER TO STRUCTURAL DRAWINGS GLAZING BEAD BOTH SIDES 6" ALUMINUM SILL #110481 BASE #110269 6" TRIM #412002 BACK PLATE #110360 ALUMINUM HEADER 3/4"X3/4" TRIM #110410 AND BASE #411331. RIP ONE LEG TO FIT 5/8" TEMPERED GLASS 5/8" TEMPERED GLASS GASKET #GG12100 SETTING BOCK #UCSB4 LEASE LINE #110264 6" TRIM #412002 BACK PLATE #110358 ANCHOR PLATE HILTI FLOOR ANCHOROR EQUAL • • 5/8" GYP. BD. OVER METAL STUD FRAMING (TYP.) REFER TO STRUCTURAL DRAWINGS #410458 BACK PLATE #110221 4" TRIM G.G. TO PROVIDE CONTINUOUS FRT BLOCKING FOR TRIM ATTACHMENT #412002 BACK PLATE #110260 5" TRIM VISTAWALL DS -1 • 1110221 4" TRIM FRP WOOD BLOCKING #41045S BACK PLATE G.G. TO SHIM A5 REQUIRED WOOD DOOR. REFER TO ELEVATION 1/A-5 O O 0 Z CaI— w = Ce Q W O 2 Ow Q Co U, U) U) U) U, O U) U, Lq O I— pEp 8 0 0 rnN N I- 0 U cn Q O 0 O >% _ 4) • C CC L_ _ a ii) 07 j 0 o STOREFRONT GLAZING DETAILS SCALE: 3" =1'-0" ENTRY DOOR HEAD DETAIL SCALE: 3" =1'-O" REVIEWED FOR CODE COMPLIANCE APPROVED SEP 052013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 1 2 2013 PERMIT CENTER JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: STOREFRONT SECTIONS AND DETAILS SHEET A-5.1 OF 22 SHEETS A TYP. TYP. 4 .G1 5'-2" '-10 1/ 11 SALES AREA ELEVATION KEYNOTES 1 A 2 31/2” A00D BASE FINISH "D" 3 Q m • 4 073 J 101. 8'-0" WIDE X 5'-0" LIGHT BOX HIGH LI .______/ n (? ev 15 . A MAURICES G.G. TO PROVIDE BLOCKING IN WALL AT 4 LOCATIONS AS SHOWN FOR MOUNTING FIXTURE 1-I-18 _ 4 r , '-10 1/ 11 INTERIOR ELEVATION At -6/ SCALE: 1/4" =11-0" INTERIOR ELEVATION SCALE: 1/4" =11-0 INTERIOR ELEVATION SCALE: 1/4" =11-0" INTERIOR ELEVATION SCALE: 1/4" = 11-0:, MALL _ CONCOURSE Q is G 9 INTERIOR ELEVATION SCALE: 1/4" =1'-0" 1111„111,:, 1,rt ,,,,,,,,,11},,,, 11:11111 :111 1,111„ „1,,, 1:,1 ,1111111 1:: ,111111111 :'„111111111 1111111111,,, /1:1111111111111 1:1::,1111,11,1 1:11111:11:,111 111111,111111,1 / II111111111111 11111111„111„ 111111111111111 i 511111IIIIIIIII „11:,:1„11111 , ::::::111111111 111111111111111 111111111111111 � uuuuuun, nnuuu,111, 111111 /1111111 11:1::,1:1111 1::::1111:1„11 1,111,111111111 N f 1 11111111111111 n111111111111r 511111111111Iii 11111„1,1,111, N o 1:1111111111111 1:111111111111 1:1111111111.1 ::111111„111,1:1111,11111,,, 111::,11111,1 :1:111,1111,1: 11111:1111,11,, 1111:::„11,11, 1111111111111111:::::111:11,11 II:,1111111:111 N 1:1111111111111 111",111111111 OPEN TO 11111:111111111 111111:11111111 111111111111111 11111'1"""'1FITTING ROOMS „:1,,,,:1,,,,, :111111111111„ 11,11,11,11:: , Ns ,,,11:11,11:1:1 ,:,1111111::,:, 11:11111111::1, 11:111,1:11,,,: / 111111111111111 1111111111:1111 1,,,,,11:„1„: N I„1,111::11111 :11:111:1,1,,,:, / N 1:11111111:1111 :11111111111111 :1111111111,::, III 1:111111111111: 111111111111111 111111111111111 111111111111111 111111111111111 111111111111111 111111111111111 111111111111111 1:1111111111111 1:1111111111111 1:1,111,:,111„ 1:1111111111111 1:1111,11111111 N441111111111111 1111111111111 1144111,,;11; © SALES AREA ELEVATION KEYNOTES 1 TYP. STANDARDS, 21-0” O.G. ALL SLOTTING MUST ALIGN AND BE LEVEL, INSTALLED W/ TRADE NAME UPRIGHT 2 31/2” A00D BASE FINISH "D" 3 Q 4-1 4 073 8 2"HOOK AT 1'-0"AFF.TYPOF4 9-13 LI .______/ n (? ev 15 G.G. TO PROVIDE CONDUIT, WIRING AND CONNECTION TO LIGHT BOX. CONNECTION POINT 15 AT CENTER OF LIGHT BOX. SEE MANUFACTURER'S INSTRUCTIONS. MAX ELECTRICAL DRAW 15 1.5 AMPS. WIRE LIGHT BOX INTO SALES AREA LIGHTING CIRCUIT A MAURICES G.G. TO PROVIDE BLOCKING IN WALL AT 4 LOCATIONS AS SHOWN FOR MOUNTING FIXTURE 1-I-18 N/A 4 T ,� r INTERIOR ELEVATION At -6/ SCALE: 1/4" =11-0" INTERIOR ELEVATION SCALE: 1/4" =11-0 INTERIOR ELEVATION SCALE: 1/4" =11-0" INTERIOR ELEVATION SCALE: 1/4" = 11-0:, MALL _ CONCOURSE Q is G 9 INTERIOR ELEVATION SCALE: 1/4" =1'-0" 1111„111,:, 1,rt ,,,,,,,,,11},,,, 11:11111 :111 1,111„ „1,,, 1:,1 ,1111111 1:: ,111111111 :'„111111111 1111111111,,, /1:1111111111111 1:1::,1111,11,1 1:11111:11:,111 111111,111111,1 / II111111111111 11111111„111„ 111111111111111 i 511111IIIIIIIII „11:,:1„11111 , ::::::111111111 111111111111111 111111111111111 � uuuuuun, nnuuu,111, 111111 /1111111 11:1::,1:1111 1::::1111:1„11 1,111,111111111 N f 1 11111111111111 n111111111111r 511111111111Iii 11111„1,1,111, N o 1:1111111111111 1:111111111111 1:1111111111.1 ::111111„111,1:1111,11111,,, 111::,11111,1 :1:111,1111,1: 11111:1111,11,, 1111:::„11,11, 1111111111111111:::::111:11,11 II:,1111111:111 N 1:1111111111111 111",111111111 OPEN TO 11111:111111111 111111:11111111 111111111111111 11111'1"""'1FITTING ROOMS „:1,,,,:1,,,,, :111111111111„ 11,11,11,11:: , Ns ,,,11:11,11:1:1 ,:,1111111::,:, 11:11111111::1, 11:111,1:11,,,: / 111111111111111 1111111111:1111 1,,,,,11:„1„: N I„1,111::11111 :11:111:1,1,,,:, / N 1:11111111:1111 :11111111111111 :1111111111,::, III 1:111111111111: 111111111111111 111111111111111 111111111111111 111111111111111 111111111111111 111111111111111 111111111111111 1:1111111111111 1:1111111111111 1:1,111,:,111„ 1:1111111111111 1:1111,11111111 N441111111111111 1111111111111 1144111,,;11; © SALES AREA ELEVATION KEYNOTES 1 TYP. STANDARDS, 21-0” O.G. ALL SLOTTING MUST ALIGN AND BE LEVEL, INSTALLED W/ TRADE NAME UPRIGHT 2 31/2” A00D BASE FINISH "D" 3 SHIMMER SCREEN. SEE S/A-S 4-1 N/A 8 2"HOOK AT 1'-0"AFF.TYPOF4 9-13 N/A 14 US LIGHT BOX. SEE PLAN 2/A-6 FOR DIMENSIONS 15 G.G. TO PROVIDE CONDUIT, WIRING AND CONNECTION TO LIGHT BOX. CONNECTION POINT 15 AT CENTER OF LIGHT BOX. SEE MANUFACTURER'S INSTRUCTIONS. MAX ELECTRICAL DRAW 15 1.5 AMPS. WIRE LIGHT BOX INTO SALES AREA LIGHTING CIRCUIT 16 MAURICES G.G. TO PROVIDE BLOCKING IN WALL AT 4 LOCATIONS AS SHOWN FOR MOUNTING FIXTURE 1-I-18 N/A GENERAL NOTES: ALL DEMISING WALLS ARE TO BE 6YP. BD. TAPED, SANDED TO A SMOOTH FLAT FINISH, PRIMED AND READY FOR FINAL FINISHES BY MAURICES G.G. SURFACE MOUNTED STANDARDS ARE PROVIDED BY MAURICES, INSTALLED BY CONTRACTOR. SPACE ON 2'-0” CENTERS FROM STANDARD TO STANDARD. ALL SLOTTING MUST ALIGN AND BE LEVEL. G.G. REQUIRED TO CUT STANDARDS TO PROPER LENGTH. IF ELECTRICAL OUTLET INTERFERES IN/STANDARD LAYOUT, CUT STANDARD TO FIT. STANDARDS ARE TO BE INSTALLED 50 TRADEMARK READS UPRIGHT. ALL SLOTS MUST ALIGN FROM STANDARD TO STANDARD. ALL MOUNTING SCREW HEADS ARE TO BE PAINTED (2 COATS) TO MATCH SURFACE STANDARDS, FINISH ” B” ON MB STANDARDS, FINISH ” C” ON TB STANDARDS. TOUCH UP PAINT ON STANDARDS A5 NEEDED. COUNTER SINK ALL NAILS AND PUTTY ALL NAIL HOLES AT FITTING ROOMS. G.G. TO PROVIDE BLOCKING AT ALL NALL MOUNTED ITEMS, IE: COAT HOOKS, GARMENT HANG BAR, ETC. E'er' W tV W00 ~u' 3 (1) c 15- 0 (53 w 5 -0W W Lim r � CO(1) fri EIN Jc6 :OWN w CC CC .4C u. Lu C*) a� 4trt Co CO A-6 INTERIOR ELEVATION SCALE: 1/4' =1'-0” 9 ✓ 9 b A MALL CONCOURSE )..bo REVIEWED FOR CODE COMPLIANCE APPROVED SEP 052013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 1 2 2013 PERMIT CENTER O w F- F O NW JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: SALES AREA INTERIOR ELEVATIONS SHEET A-6 INTERIOR ELEVATION A-6 SCALE:1/4" =1'-0" OF 22 SHEETS NOTES: ELEVATION SHOWN FLATTENED ED FOR EASE OF FINISH DESIGNATIONS. DOORS COME LAMINATED WITH STRIPING. INSURE NAT STRIPING ABOVE DOOR ALIGNS WITH STRIPING ON DOOR. MINOR ADJUSTMENTS TO DIMENSION SHOWN OF PAINTED STRIPES FOR ALIGNMENT PURPOSES IS PERMISSIBLE. 11-2" It /_II 11 II 11 11 1 '/21' 8" 1/2" TVP. " 1'-b" 1 /2" _10" 3 1/2" 11 /11 8" 8 1/2" 11-2" 11 51/2" 11-2" TYR 41/2" I r_II 11-0° " 81/21" I I_II " a" r_" 411 11-2" 8 1/2" II II 11 21/2" 3"I 10" 10" 1' b" 11-0" b" an 1-2" S, 1/2" 3 INTERIOR ELEVATION - FITTING ROOMS SCALE: 1/211=11-0" z O 2 z O 2 z O TVP. z O WN W C (1) 0 tt� 0 W W Z z VJ 5 co = N J co J r N N— © k�� {M 14 LOVE IT LEAVE IT HOOK AND BACK PLATE. SEE DETAIL 3/A-8. PROVIDE BLOCKING IN WALL. 20 if -'•i Y 21 is 22 ACCESSIBLE FITTING ROOM BENCH. REFER TO DETAIL 12/A-8 23 Fj: .1` •4 24 �T. NL. maurice5 G,C. TO PROVIDE BLOCKING FOR CLEATS TO MOUNT 3-1^1AY MIRROR. MIRROR TO REST ON FLOOR ADJUST CLEATS AS NECESSARY TO ANCHOR MIRROR. 26 •L..+ 27 >h. tra • • 28 PENDANT LIGHT FIZ URE "Z". REFER TO ELEVATION 2/A-4 FOR MOUNTING HEIGHT. Y==�: xt 30 .r." tel' ,�.i:Y S:• ! t �'4 -, 1� `I 32" or rry rk, f,: t. •ti i *�rx •. t ` ,4 `•Y s +t } n,4.. Y �'�:-.•,�: C" ♦CtC`:. .:}- 4ti \"':.:..:- 7 -1- I 1I r .r,�, } /�- O O FIIQTG R5 i 8 $ \ , \ / \ O J Ly' . a : 1 O a rc ON 9.5ny N ___I I I r .s� �F i '�: •5 'r ` ~r.'. .v ri � ci ` 2 S:Y•, 7 o-[• t •, :ii tix� • - r. .z W` �t L � r: ' f. :.�(-r: Y 1 ; "f. ,.. • r t� • v xt•' Ne •�:T• . 3 ..✓:••',1{ ist�r,• i�='i ,J, i�' _ ;�L; t s...., �/ O N O Y' FIl`TfNG 5 ... , \. \ r�1 TLs.+ `l / •I r r-,^ • • , ., Y M� om+•l \\ • ..: .. N t t� f 4 ` i? ti r ♦ t ,.... r e r. ti T 7 1 ___,..., Y '€1 �_ 1 1 _ 1, I• 1 _ _I 11 _ INTERIOR ELEVATION - FITTING ROOMS SCALE: 1/211=11-0" z O 2 z O 2 z O TVP. z O WN W C (1) 0 tt� 0 W W Z z VJ 5 co = N J co J r N N— © FITTING ROOM ELEVATION KEYNOTES 14 LOVE IT LEAVE IT HOOK AND BACK PLATE. SEE DETAIL 3/A-8. PROVIDE BLOCKING IN WALL. 20 LOVE -IT 8 LEAVE -IT DECALS FURNISHED BY MAURICES, INSTALLED BY G.C. 21 GARMENT HANG BARS "A-4" AND BLOCKING. SEE 4/A-8. 22 ACCESSIBLE FITTING ROOM BENCH. REFER TO DETAIL 12/A-8 23 3 1/2" I^1000 BASE 24 FITTING ROOM WALLS 25 maurice5 G,C. TO PROVIDE BLOCKING FOR CLEATS TO MOUNT 3-1^1AY MIRROR. MIRROR TO REST ON FLOOR ADJUST CLEATS AS NECESSARY TO ANCHOR MIRROR. 26 N/A 27 WOOD SHIELD NAME FLAG:DES AND MOUNTING CLEATS FURNISHED BY MAURICES, INSTALLED BY CONTRACTOR. SEE DETAIL 14/A-1 28 PENDANT LIGHT FIZ URE "Z". REFER TO ELEVATION 2/A-4 FOR MOUNTING HEIGHT. 2q SIGN HOLDER INSTALLED ON INTERIOR OF DOOR IN FITTING ROOM BANK AT S' -b" AFF TO CENTER. PROVIDED BY MAURIGE5 INSTALLED BY G,G. 30 2" WIDE DOOR CASING FR.INTERIOR F.R. EXTERIOR GENERAL NOTES: COUNTER SINK ALL NAILS AND PUTTY ALL NAIL HOLES AT FITTING ROOMS. G.G. TO PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS, IE: MIRRORS, COAT HOOKS, GARMENT HANG BAR, ETC. 4'-11" , _ 44" PANTED 5TRIPLMG REMOVED FOR CLARITY INTERIOR ELEVATION - FITTING ROOMS SCALE: 1/4" =11-0" INTERIOR ELEVATION - FITTING ROOMS SCALE: 1/4" =1'-0" INTERIOR ELEVATION - FITTING ROOMS SCALE: 1/4" =11-0" STRIPED SEE 142,h-6 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 5 2013 City of Tukwila BUILDING DIVISION N ' ::k ::GP t M,..4.r '1N T*: TY' ON NW AV. Z 1— W Q �o 0 w cle 4. ow O1— N z (A N cc co O u) J J 2 E O U C) O co E N 0 CL cn a) O a) u) c a) O m 2 v a) .O Li In 1-1 LI LI LI RECEIVED CITY OF TUKWILA 6-61/2" AUG 1 2 2013 P RMIT CENTER 6'-4" HOLD 41-11" 4'-8"mow -..14 41-8 1 ELEVATION A INTERIOR ELEVATION - FITTING ROOMS SCALE: 1/4" =1'-0" ELEVATION B INTERIOR ELEVATION- FITTING ROOMS SCALE: 1/4" =1t-0" FITTING ROOMS KEY PLAN SCALE: 1/4" -1' /''" JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD—SS/CJ APPROVED BY : XX REVISIONS: FITTING ROOM INTERIOR ELEVATIONS SHEET A-6.1 OF1. 22 SHEETS U \..--. ' • • • \ • • • • • r—L._J— o FR.INTERIOR F.R. EXTERIOR GENERAL NOTES: COUNTER SINK ALL NAILS AND PUTTY ALL NAIL HOLES AT FITTING ROOMS. G.G. TO PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS, IE: MIRRORS, COAT HOOKS, GARMENT HANG BAR, ETC. 4'-11" , _ 44" PANTED 5TRIPLMG REMOVED FOR CLARITY INTERIOR ELEVATION - FITTING ROOMS SCALE: 1/4" =11-0" INTERIOR ELEVATION - FITTING ROOMS SCALE: 1/4" =1'-0" INTERIOR ELEVATION - FITTING ROOMS SCALE: 1/4" =11-0" STRIPED SEE 142,h-6 REVIEWED FOR CODE COMPLIANCE APPROVED SEP 0 5 2013 City of Tukwila BUILDING DIVISION N ' ::k ::GP t M,..4.r '1N T*: TY' ON NW AV. Z 1— W Q �o 0 w cle 4. ow O1— N z (A N cc co O u) J J 2 E O U C) O co E N 0 CL cn a) O a) u) c a) O m 2 v a) .O Li In 1-1 LI LI LI RECEIVED CITY OF TUKWILA 6-61/2" AUG 1 2 2013 P RMIT CENTER 6'-4" HOLD 41-11" 4'-8"mow -..14 41-8 1 ELEVATION A INTERIOR ELEVATION - FITTING ROOMS SCALE: 1/4" =1'-0" ELEVATION B INTERIOR ELEVATION- FITTING ROOMS SCALE: 1/4" =1t-0" FITTING ROOMS KEY PLAN SCALE: 1/4" -1' /''" JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD—SS/CJ APPROVED BY : XX REVISIONS: FITTING ROOM INTERIOR ELEVATIONS SHEET A-6.1 OF1. 22 SHEETS 31,o REVIEWED FOR. CODE COMPLIANCE APPROVED SEP 0 5 2013 City ©f Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 1 12013 PERMIT CENTER I— III N cell' Co Lo V J F - (i) wu) Q 0 0 0 rx 0 w LI_ azr DZM () co Hip.aj (/) 1 =N w E 111,D C 16 J r CJ N— :: —h- LLIQ cei 0 :moo N4i=1 ,LU Cnt CV Co 0 0 co O U W V J 2 —L(Lu Lc) ) LL �y CO WWLOU F-- � O 0 co u) U=0Ce W ' U CI) cn LI W 'C(to co . 0 8 8 0 0 Co CD v N 0 CL Co CD 0 a) Co J. w 0) LO C Co 2 ^V W it O W ha- L.L. O I— N z J LL co 'L.= `c w c° Z co DEtw0 W V i 00 Z w D WuJ _1... ert ,_1 ,... 0 03 w Q CO c Cl) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: WALL TYPES AND DETAILS / NON -SALES EQUIPMENT ASSEMBLY SHEET A-7 OF 22 SHEETS ' «-,,, C.`: s\•i- r( TR TO INSTALL n E A 4.'..ii\Ro RAC xomM nryF „}\l ) \:ii5L ., CONTRACTOR \„t = YA":si-loINN ON FLOOR PLAN. •N; \ )yr NOT r� J££ • Jf•-„_."•• NEIN _ F\tMETAL ar�LREFER STRUCTURAL ,te £ F - «Fc .. , ,�,r .`' \a=RININSS ..N , A..._.,« INSTALL 's Oi"""'` E BO; BOLTS :` ALL `CR `_«:,,y`: _".'"• L...«, R. Com• =a= ..,r -• PLAN '----«„-„-, t `LJ \ ,£aC,FE.1 MOUNTED w 'AEr'T.C.':r:\R :v' iEE Y` ,. 'STUD FRAMING. ; tNG: R ,: R .TO STRUCTURAL PRAININ0S - :• N is N.• -TYPE• r ",: D!r ::` STRUCTURAL :RAY' iNC. 5” FLAN N ;moi' TYPE 'P FLAN ” 9 S _...._._.« \` •a«AF's `\ Z 7N:_ \r . \C -fa., . ..-.+.ANT E «. N a. ,- :'\ .,_ J; soAL. r,t r ««_,. CARPE, -FT i:C\. APPLY CONTINUOUS BEAD ,.a• �E...k','� :ALONG' :\C\ "w,:�rE C`i-,;-«,w:i\NG SHALLNOT BE VISIBLE AT E r;.„^ ...__. ,,.... :SURFACEMOUNTED STANDARD , i'\;t�:r=. - - 2. ,.,,,r ,Ex,, .,,^y TYPE.+�:,.,, / _ �4 METAL STUD FRAMING. RE•l'E'R To 4.. Srf:ZUCTLFAL • • 0 NEIN � firt. :=:Y`it':",s' r REFER TO •r r\� .2-1/."2” STUD«:� • • • -,-.- \:,AFZ:Td P:\j."✓r5 APPLY 45 \r- ff,., \F`Y. 4:-# N .:NG BACK •�"::%�:,," M=x�.":.. :ii,�:hfa :,: N ,y.,fi OF N. „ . -• \b• •"3-•::•/0," • + .E- . AL f' F SECT ,ON - .o- F3-4" k\IOOD fa'r .,` .. "K2", S BEAD OF APPLY t. . \ h \: ` ' TOP...r.t.O- BASE, iA;wwN , SHALL \1"�= VISIBLE ,1T „`.,:�: (;)F iz3ASE. ' M:C.. li-,.. . AIG`a'\i- i,,, \i "Z„ . , .. :'' t\n,.,;\,.. TYFF r�..,. ,.. a• N�.At.t,,.,`1,,,, TYPE: C", AI ` At.„ , '-r'Y ...F tT3`k - iiethi `�>'�`..'C ",'\'' "T «j :E'.. \ ? ) n' t,^w .._ `•t = ^r' i - )nT ..."�i,., i E�'-« MOUNTED, k'�:`'rS--C,. .,.+t.:�� T,.. hp+rt STANDARDS .i'+ay,,�; :\\i,: A�£. .•,«.... ! P_: N.y v h. ,,..,,.: :...,,. NTS ,.. NEPI A, qi 7 a t � NC.a \ Y \`aLL,::... r•'\i;'?a.1 C.• � ..a,.. ,�• Nr• �E. i-rc,.,,-.\ SURFACE Za.-: i �\ , a.,.., ,_- k„� .{\. �tL-°.. ,�8.,. '-A •„,-`i^'t•Y .i,\' `1 ,; y".+:`)T?\�.F .., SCALF: ;lw uy 1 i� E~« � VIALi„STANDARDS �'t....k S i``G.\. t .. 2,,. • . .. ._,n \; .. .. NEIN 1.. ,i'•.: :"r -r:' FICALE: ��r. i ,. r`\ r`f ,,-,. :=r: i 'Y'� >\ ,4., 2.. �::.., .. t�E ::J \.,.FC,. t\\..:Ni \r`\ii,-..,- FRONT' :�` :•Y-�..• SCALE: ,E-.�E: 3�'' . ,.. lir S \;r air a`r +A`i;Ge i,�'^VAA .. ax 7 it . ,<>�?i - >c $, ,;. vit.. t Ass,. .j n\,• �: \d' •. •au tp 1 ��\ .t i" a, E:''aC _ ^.t .�R;: • A .`Z;i ` J 7 $ \.� .. .'....-....... E ..\, ,. a. 'n,i Aj" sYri„':"`ti, • i ,�•,...._-._......, ,..--«,...._.,,.... ., ~E ..� 1 t , E E \._.., --N\ Z. a i E r;\' A %r teR E_ N N\.' E,' ,, E ^ ..h \ :: } .2 •\ - 3 a a E -: ... C • .. ; C«, C u 7 `. •= k i .- r E v \ n ....:' , t ��� u 3 = t 1 *.... cl .p„« N \.,.'F• , x., .. _ u F IA S��' VI Z E \,\� t i .«.- j) e,">C .. Y itu: t,.•: J (..,( - Ez;'�::= CKETa UF1'LiEr fQ J p >_' '. 11- 10 ., : r AND IWTAI A. «...`ila BY C:;v':'Cr 4 • v.�i a�.T Ei OPEN END' OF \ NJ,' r ; i U g FRONT iSIDEELEVATION .•E ELEVATION FRONT \ SIC. ? N "\=",a'N Vax..\`\ a .1ME.. "tn1e\ i (c -z) Cr ” 3 WwONTA"wrc�«�i.7_ ....... ...`«e x `, PART. , z s t % r�' MOVABLE., cT y R' ,tt£ -------- i @ d tx. TRAC•K w\,a"„",a"12./Ar". •"\:: r-„-}•, . ” . a „ ., SLOT `, , .a •C, 7N ```. tl``3Si,:n,:',.. ?\,i.\,.ac:.•i?`\\i,.,.-. Msn N s:,a x x"<l�..\„, ,,.Fp ,x•'".�,.vxUNITE, ARE rTHE `xfCRIVET. ALL , ``l „w`:N\" \"Cxi@\INSERT INTO SLOTS r,v; ANi."a G i+S,,,%,W•EW:Y""BOTTOM _ i 1; „t t,\ `t« .e;::.. ,, ..1,,,, � „\t. � xm,v ,,,\„ r ..,i A" .NT ., •'• „\."`• �T a`;;' ar,,.T ^,.. .,�.. „y •T ..A` :•.) a,\x` I , .�, PLATES,•�'S p -,T OF •'fit: E :N ,r t:` „\;'\ , a.\., rvF,C-, •,4,: „) G.' rs, POST). TO Y�:' ` Z .^`i r^C , . ' Gr\ ., „ Ei s. , x FRONT. , . � - « .� s., , i\.`` ,«.,« wa . ,,,,, , na. , .. ,y .„. �\, „ ., .. ... ^„ sot:: „w ,,, ., - \, .a . ,„.,' ,UNIT . n, �' C,a' .,, ,. ., .. �., �. .,, x, .,x „.T :1:: Ee.�.� ..,eta,. �:-r+.i i� .d in-`.,;';.. -�'2 �w i:..tA li'::T \'1 \ 3=:.; `2f” y`.,.”; "�i t",J }`�:Y”. •\ e-..---.)rt,t� `��i ? t, .��,,, �<:.�• �,.. �'�• i? L,xt..M:,.:. ? =i`. "ix•JC,a' i : r \� � ^`��eF,.a> „a,.F;„x• ? \,-•aCx.>..,r'� ,• i`1:.,.`•' ;�t.}.,.•.r`'?%..J;&r\• :'.a, -•a ,x':.'J�.,.`:. 'x',Ja,i• ..,>A.,.�,.. �,. N "r' :\ : K) : t.„/ i t -u......." :,,,)i .o A,,.... a\ ,,\ .. A„\E. a„`\ \a,� "r £';: --i E F --,,ION 1: t 'n \„ PRC,,VIDE:. , „ L,.A'r \ \w•r ^"\: Crin.:' n,-: f \„•T t `t A`•„ ,t `��� p, �, . :w•=e`\r`Ste:�•',\�'.:a'i"';?"E �:`+. ��.�., TO �.:.�s`�..� IN �'i..nt'`�£\.,-=i.-." aLk Mir ENrs cAr DETAIL AK NON -SALES '.,:.„ J\E C.. UNIT Aft NON -SALES " E N`w UNIT ® �„�"a�fi"\ STE- ,xa UNIT Alk ^hE N? ,N.UNIT PEPc.,a".2.MR UNIT . . K .W 4h - JS: „.EREt3FV•N ,f PI Otw. 2 HP UNIT = E c5 HN UNIT .SIGN� :.a.::aRC.a " glir PiPe121 MK UNIT - ,,. „Kaa». \" a 6 a"r PLATE AND"+%`viir HED By \-I :4" C«N%oai:` OF ✓.E' Ex•T,•y \AROUND iw i R. :„..."-"F YrC.•\ " E :-C N 11111110 l SRN y. ii Y? 4 r. 2. 33 t It: . • •.:• n , Q � y �.�\. �I. -f d 4 4'Q 4 Q p . d ►I .i /=^, :',••••:,,. �i`" y a' t��\ �!� .A H ? � 4 �. v�ti �ti ..,,,,,•- „3, , • I OF ` rg[ i R E `,i a r,,r .• �t ,«. I � I �om : aC\r,i •S ZhuH•ia.) S_ ? :N' \ .-:\ SU`.•. '"-;U -'Yc'NTF ..««.« �\N,'i��M,a .iC:a"\��I �---. NCN.`.`.\w..w.'✓ k�N\a :Ar«R ,-• •.:.•;�: METk... Ni=Y-,.`, Yr_...\:N: u"~r :, .T� ! " r` SECURE "t "• Jc t - \@ E yRG « a„k f ( \ 31 2 F}3-:,` i ! y E AN .\„i�a�N ltT A,Lsa „ „\ ..4.-• ;\) ?CY• d1xy> t i m xo\ua`f - 5:, i\"�rnViw\�..«- S\E,N\ TRANSITION TRANSITION TIL.:,.-7. $ \ \ A i.0>. f iCa%wy: "ZPd.x�t > £ Ja i nY` -\�H7---„ w\4F \ .E\\ ~.a,f .\; , e E \'F; PLATE.•ttOc44-IALL Nc.ST \ \` ` -. :�' \. • „•.• k «R�i\C �: i,, : a \`ib1 : FINISH F.ar \. ,Z "ti' ..^c'„+•. f ',-y� nADHESIVE %E i:„yFRENCH CLEAT AND . Z- P NAk-1E PLATE. ia-.„"� &\y"y Y SNyq • M"RF FLA. -E. r -r N. ^ HalATT � N.r y'.. F _ � lit it .� .14'`\\ . ''. rr 4 .. l.T .. ..I ✓ • rfFe. . \� y. ^J m ` ar`y\n4 It\� • 1' AFn«bS.LA _ 1 SE a �. I N . \ _�� •C;y , p �• , N ..Y :'y-' `\£ - p i =\,,,� .1.. ;'ti''.: • TVIC.-.) .'n'1.7:••00R2' . 'a \. i u 1 \-nit i rpt : N"\r,. , W• w.. F€TK €N v} ROOM )OOR ®„ "e„Fw�l A? a„i s3\ ""* i 1 „ « .-, . A�A�' �"TYPICAL ",,aRia�r .,Lafier:.iE <t v.x ”,u\ :' "\>"'\ " A Y. wi E i ' 3t ` „ DOOR O NA?', -1E i „en rvW E,k3,0,-...%„ .E'w`aE i:A iiw ; ° ?„ i it\x,.v ,1, m\E E3ARRIf5_"AJ.'�p.•�`a)M W '54:ALE: NTS 31,o REVIEWED FOR. CODE COMPLIANCE APPROVED SEP 0 5 2013 City ©f Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 1 12013 PERMIT CENTER I— III N cell' Co Lo V J F - (i) wu) Q 0 0 0 rx 0 w LI_ azr DZM () co Hip.aj (/) 1 =N w E 111,D C 16 J r CJ N— :: —h- LLIQ cei 0 :moo N4i=1 ,LU Cnt CV Co 0 0 co O U W V J 2 —L(Lu Lc) ) LL �y CO WWLOU F-- � O 0 co u) U=0Ce W ' U CI) cn LI W 'C(to co . 0 8 8 0 0 Co CD v N 0 CL Co CD 0 a) Co J. w 0) LO C Co 2 ^V W it O W ha- L.L. O I— N z J LL co 'L.= `c w c° Z co DEtw0 W V i 00 Z w D WuJ _1... ert ,_1 ,... 0 03 w Q CO c Cl) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: WALL TYPES AND DETAILS / NON -SALES EQUIPMENT ASSEMBLY SHEET A-7 OF 22 SHEETS - . ,+i,•F��, E w.3 ; h 3i\ti"F rte \:� . Na '�3"Mai _,,,,._ I .w 1/4" ianaw J OPENING tE",yfW"t`2 aa HART) 1,o.•,+� a3�,?L •"FihY M9,:N:PLATE ' ,\i`.t• F IED ! - a V . !METAL! C,.F,>, " i „?„E�itiV �C .D .�MATCH EXTERIOR FITTING c. ;? 3 \ c,,ter:;te{,,,,,i i i L_ " o\ iFJ ,s\\A„,CASINO "�' E1, -5.f ♦,'3 hAdE t`�,,,Z INSTALLED i ii �.�. • e ei\1..4_,i.mr:.2 \w•';,,•;..\•a,,: _n ,\�� --I' 'CHANNEL TRIM; "\aRENC,L...-\-,„.. 4 7 . • MPHI-Lin rte \:..' ee�h»�- r+v`\\\i,' co 1::r 4 / P: Z , 4 a_@r x C f I . ' Nrk -&3<�• \ • „ » _ �1 41 %;HA / •,f; • ) soli.__ ;\ �� hil L E i � ,\MASTIC,.Cs ( ��at a "i ,. �i'`1•»T t }'I.\£i' . _ .CCY ,C.V,<, 1.. I3 •C"i Ye a.rl": BACK B". •01 .. PLATE 4 E�McINSTALLED � AND HOOK . } '; FURNISHED `.f..,h. fr» „..... .?\C„ AROUND wYi1. Mid \.•i.f: e ;f 4 FRENCH E ✓"'5"Et .�:.,.\, n, SILICONE. SHALL ,� � 1�vi.^`w \,�\y.��. t „:. EASE rY'C T,L "?-w': \e „ZR` al ..l.�V- „IAiK, PLATE: {i Z\\ \`ENf:;aa,ew uZT \HiM"•o a . L i�Y MOUNTING 3ti�jaKIM THREE � � "",:X." AM `^N. - ` ! AR <w , BEAD \ A<Y .iCL�`E;�ZPLATE \\' q.PERIMETER _S . w M^i..:iCiCi ^1 .♦• aT lT"..•_a.\ .L✓..«.`{r?YCih,� ^ ,�.4•, TO MOUNT HANG. .\� ,\»KC�".r'.", ' F f�»...♦t`.7 BOLTS ^.\iy`",.;PPt „•- 77 1ra)S!» S LA7' a1 -A• 43:��i '..?+ _., ~ -, TOP TRIM r' / / / r • . ..h1.i:5,A"�C) Pv�Vw��y ? t: tic,.. -)IL .,Lei ":��R)� ''•»�:.:I:"FS 1 2el Z.: 1_• ?w;Y<:, op t _ + ` \• e1iE ��wSdVi\. "�F } w .�r�ww ., ,om. ` ��\ : tL E ,. {Ri.M _ .f 3e :,'N ,rEt ..• NcE R*,.te0 f,�,E°,•,», .AS ♦ NEEDED. \� \ snipe f: t C ' \:". , •\..` i x :r\"tit:; �.ir, PRIOR ' f,\ i •�,••` \ / ' i; ,h• �' i g 1:; . \ , LINE: l I 7 \� _ " METAL �® / f , s \^ i \^ .o- ! \ ,. <... \ INE -TALL. aucoNia AROUND PE'RIME!TER, OF �•\..>�"r.\ „tf\�l �, , .A,a.•\...-. i,.,:. : ;» i,iC E. ;:\`: �re:t•=.(4.,;:s.:, cf,.i rw,rti:La«h ",,- .,..j 1. \„Z".. 1 Y ." ,o .a 54.„(":::,K kt'""� .,.__. \4w- iiii ‘ + MA f ,.., x, PRIMER .Y r __•_,• 5/4 A w ', 4-1.1.C.a,=2.I a....cxxiNo ....... ts:Nz ri,_.: LL_ BLOCK .Ix• .L\\\aa:�:\:a.\. - f �' r ,Sup _ I.,ff' . M '-X NIIIF I Ilia IdI �tI AI I .. I I E ,biz ir_ pS i ,I �`/ __ »__ ... i . N`L ...._♦ "i•3_.y TLCtN AROUND::RIMv»Ecei: \ _LCK1 TSILICONESHALL- NOT \ „••., Tpl,.. -... u � \._..,. yY.`i ::. :3.0A�\HCt o TDANCV „\:,. `2TT..T:; ` A.' �„.T NEEDED. i�.l'. "t. w " "ttEs - x` - i Z / 1 \ \ r; °�:3t F ^` i .._3: � �;�;`S\y.»• �S:t" ?V:T-5a..,y_ .5Y AIbEiINfv Lwa• <�^..„pi„-os,-)or, � .`jR;,\ath1 i i4• M7 ,,:E ri". Zi"'e• i =,.,o` .^- . E"^"`.�,M",^„ .,.., ,,.•.,� a ,E `': ,f itMk,' C �,. {t,�„'z", Ifo ,�3", ,< r { ' rs," .w, i t :,••�•? N . �:.... +,,,_" '�`' .,•` �.... •'i 4 A t , • 'r� '='t'i ' t'Cori / � e 1\•? . <„••• w. •' \..,•S� <' i e":,.•-`<t • +^`\» OPEN E 39 t"' _r w', (x•",y E' ='... • ,„r.'. <.;)! OR \,... �,,.� SQi"-` ..., i�:.�,..E>..,at�" �`<,"�. PAINTED . ,...cis E �.,•i' " E MATCH ::.� ��=w qa =;�__�. R <�, v ..Yi -t-,.�`t\w`,� ......a," Z-- t \ _ ( 1/ I �� 1 '`•a < • / / /,15•C,R: yi ma` .- HANG -1.3AR _.e .� : �`: ` ,-3.' tr�'�f.'.. �v ,,,� i�•t,< ,<T'`, .�`�•' ., ```"' , 15. S. r��r � :� Sr) PANCAKE r\.SC :Z w I:• � BOTTOM TRIM :N, h_ G ._, SS�MBLY :�::< t <.,VW3 3 . 7:10,---) �w�t •,"\� F Via, . r pp 3 a\A�.. 3 T's:; 3 3 E " y Z i' rZ i "`� i ,<�,aFT 3 :\,mut •d'' aa' ,.•••\‘• t ,,, \ ", , \ i,,. ,,,,,), � � ate, 3 z t� a \' . Sr< : \,.o in,-- ' 3' 3 a' t\ „< ,� i �,.., �, , .a i „` o 4111111111 <. .s :' ••" �' Aga„ t A< \, ` i T,.."i • "`C � `� >\ i ` HENT " r ° �� ; � � " , � = _ , _ .................. i�,��1 • --STRUT HA :� t\( FURNISHED ;AND I..,.T ;t�. : 4?b G✓ i l +' i \ ,. » J ,w.. v t OCK NUT AND v\.Aw:HERA`� �'�y I�':':w_�''Et ' % }L;�r>�\� .. C"tt .\,F:f: iY;\,f) \:_,t,_\.• 3 t�t f at\L..•�•'<.v''1,', UNI--STRUT'Tiw�.'t-�i",3-.�� r» •f :---:` ? t� Vit:: \ FINISHED:r :\: r»• , \-3-FR r: 't= A:;.• + )#I , 1L,. T ,t•M.- STUD �?, 7/ .,,i e•SRI •; SE '•\\ "'.\ y. f" NAL ..ori': -4710N) i'- -i`.'• -.;,�. :_a .i''w. ;?� LENCYTH.' ice. Ea. A., i»? :::ice. ..<,_,.,, .,.'vCj?ti i: -r•,,.__.-"__,.._,.? REPRESENTATIVE ONLY t Ti'.'1. ^ -1 an` 3$r` s _ 1 I ...................„_,.,,,,...,,,,..,,..,,_,..,,,,..,.,....._..,,_,,.._..-,...,,_..,.._......,�,_,..,..r .05("„) r4H;,,, ALUMINUM FACES ,. GLOSS s 2. PANTEE.)----, E .050 ALUMINUM �'Z %_, D f `, I.�. ),.; i, i,� N4 _ •�4 FACZ ,..\ : `•t A i J w . i',i p ,,.. = se 7._t m t m • \�,\ ; t2c ,` :• •`X.`� I `` ` y 11. ' I II, E t 2�' al E E I t PPA E' `J� ri / %• • r i. =--i / N 1 iI = • I • \\ALLm w.;„ Al2 ,♦_.' ;:,a ,.. "=i .- .•f ,, :., tw• ,•s. t 1., pis METAL �.',E A.:: , \• :t E>..) ,i .i .,.1 E a, \ ', �,i't?n�t<•1EI.' AND INSTALLED ES-i-S.C., \...---! MEIN » .�a�NNEL F:••=RN ;^)f-iFD EY' Et \ tl kpf_ 01 II ' I _ _ ..-.:1'"P BP. ` iI ? a E 1111 III • '1 E 3 I ■ /110 >•f / •I -4----- e r.:" : \ j ts, t,,.f l..' „_ ., '�:._-.. HOOKS a••_\gQ L.. ,.-._tC'_ '3 "` i`;'^C4R,�.E- • r'`..,:.. i:.,.-....�.:�4.Ni'• r -•\•-'.-..i �-ii C, -, .;`t,,,.a'?'\,: . L:''\? 1i"ta,:!,i r, .y'-:••, C,a• i `\,-•i :;,.d t rON E AC ,R TOUCH CUT . _O I NEEDED. t "'Cw'L„ ., YM PANEL, '• »r:.r . �Cw•..�1.,,C_.- �, ; ONE N ,.• NE _..__ ,���- .._,_' w'� 'r1` \.3.C.,,.-„-,.-„_,,,,.,, ":••'« i:•-.a`'t :w•, :::< `� \._»._,..,..-_..<..\:: ..... ,i::,e HOOK, F._..-•` 4 ,_7..,d,, i E�.'' i ,� ..2 � i .{,.tx"'\::. TypicAL. . L.✓1,.. C".ii' ,, i•`• OF �� "."7 .., ANC; t EFS•` tt""Z ..:)rte, v,. " tx.. ID CO ';' O t I C,,: :" \. :•`� �\ ., w."`�.L=..✓ FOF,'. .i\',x :: �••. ".,.E,`i: `„r•.i,-: , M,E „_ ,•.'2„r::.. fes. ,.:::�� HOOKS ;Tt �� t� 3 i`i' L..•+?�. � � ` ' f ^ LEAVE .,-+, r\� ,C�;' ' 1 rF`::.. w ! )C, GRIP. ,..:: ...... 'i'Y �M "-' FAINT P E •"r .E, : , . yN,..t' . l-,- , IN 12" X 5'--Oi„ W\---....,,, .� •» I\i:.:t?iQ`C.: ;:tiC:.�w, f�u'::';`a.,i ti..t,., f.-i,_T• i" 3.a "` 3 `• :) ' . w'? i;;.+ 2L ; moi• \ �� HOOKS, • � 4 i ( :•".T.., a. -�c�� \w it 4..; .M •'.,\..i.•,-)`Kei „r3Y 2 a,. ., iriti.„ �' ,EF�^� � :C N , t A a i`. „» GRID :.-.+ _ E E E i I PANT M • `� INSTALLED ° C MATCH i`',?Cwt . C,.+i:-E6.- ___..,. :. ----''.1%-11" LONG •,.•. .. .t iA,.3i, ...•. ...:\, t "L^•\,i\I��?'Ii..3.».'.),� ?\.,ri?ti"..t=•»'-�:v, Ee'T`z t: :\,3 E:"T , : i E_ ■ ! CARRIER L_.t�`,-. 1 :`tii<[�..i:. I I,,' ■ @ : NOTE :x..3:"'iia •:. L)i .,,,,.<,: „\ ti' E3,.`' \.. r \. 3' T `'�^ •M »`,i -� L.,i,I' NTH \.••;C.. r H.. �.. ; ? .f. •", E \ \' ...'.. ;'-TL»3.�..:�:..i? .e• i3...a'C.`;�YL.. .,: 'I t..•r?'\�,,;- ..-...�1�',,.�,.?\.ii..+':`i� E v. = cTT,•r R :ate,.:=�••T,,. ELEVATION S .....`�i ,,;`C.. A... ,,,. .. v BUILT ,.,2 ,..- .r\%.,.., LETTERS �:t," .,,, :`- ir"`l, T `' \':,2-«Yt;.•` .`a r-4 a.�`,,.".,:: _ +\.."'C.♦,f:ti�`s 3_.�f MATCH l h,, . `� 2' ..\-- t \. ,f-,• ,a,.i�<) <., SIGN i`C.. ..:....• _'.•''3 ,t\`:- "• _ �C; .., h.:�:. x:Lil BLOCKING \, L ♦ �-,c r a ....�w r�'" 3�, �..,'•,�L `,••'•i``„4, _ _ _ a':. )•'` �E ",.j �.:C`±1 E:� i i .,y.,... OTE .`,t,_ ' SUPPLY ` EHI •` cTr ASC- irk M Z.iv ..IC "3L•t4:. REMOTE P :.\t:' SUPPLY lin,., f':::t:-, .�.•,,, ,,,,,,,,,,,, d' ; ? t / / i i _..,Y,. SHIMMER c:� r t»^ t METAL "i ,r.T; .... - ?;. .w. \.r "v� ; 'i. 3 . 3.. G.,3 r 3 A.- - AND -T' ? •�''.. \,L, FROM„ ^EN ' Vii PREVENT . .=1,N =-�.i,Z i,:^,'..,f �Y • , ., ,- .. \�" \..., .swA. vt t.- a.,1r. ., "` _! " Tit:: a�Y?tia, �_. ? c t --t ` .••' 1FE w �t E ;`\ � E , � \w x ,y ANP :. t; "� _ti' -_`1 `_,i x�iw,Fr=\%,.,., ARE ;�Y%.' XI F>- 1 E i � ` L ..,, . � : ♦, t L a �'".,..♦`.�;C�'3`�,Iw - ."E3�.i{,�..�.•• $i Z�\` t ::`,`..t;; .,.i.,.i♦i.\ ,_:\ \: .i. -i, ".. .-\:••, Fr! ---.: .t : .................„_._,,...___.,,-,.-...,.....__`...,...,_..,..,,-,..,,,..,....-....._...____...,_....,,,,..,....,.._.,_,..-.._,.........,...__,.,_».,..,......,-,.-.....,....,,,,_...._,.. .. CARPET Cs3E •rte,, ,•a\ ,�. ��:m`LA. ,�p i0 ♦\w<, v' wro , `r i y :� :�'r , o F i 3 3 a �i a,....."‘,..0E a •• :.•"�. a "` �n Z� .< `"FF ii Z ` �., , = r„Ae`` < '` E ,o i2� , 1 < . r -. � i r ? o F t � e g E: � +.� ? i e " a. _ a '� i9�`, °� ;i � S i r"" $ • y F. s a< ' i lw..� .,"" r x•.,,..<t = 3 .� � a„ •�� t i �t ��"`� ri,�, i s I, ) t -o �' t (.. N 'r:,,- x,0' 3 L \ a i a,�3 ash s 3 ,tea _ '� \ � t i y3 I- -- �L a` 'a*..m ♦., 3 a,• �. 1 "a � t o�< e�`•,,,e-, o\,.. ,w„ E i ", E E �" U E 3 tt u» 3 E i e/ r: 23. ate, 3 r t °s-- :. ari NSA A-5 - - s„< t,,, ,,,r , � m ♦w h ,,.,,v ,w `�" „\,o":‘,....,. t\„ ,.`�<..,A<w' i : I ! m•,« I ens- 4,,‘"r l "`" 3 £aii,:Za �.,"°r iiem" ! moi.," \ - u' ♦ J - \ ,� $ yr' k. 'r 11 as • - i N I .:E i.•RUE,- . ».� h \`\?� a :^\%:r i.:. , • :.'v TF i~,i1`•I:a,"',- F �3 Y,,C9.-' +x+�,�,� C.ZY 4•` < AND ? .• _. 3 i C i`' i \IEa , �, . 4'' i P' \ .. v , \ 1 \,` � Al` 6,C,, TO FROVI1X tai\u:�,' { \ \.` 5%:v' AFT.® F ;"t`�"^ti� ...., i •,' ,'11., tr i 1.0 ."u,^r'•-w\U4w. I a , . i'iTt...i�.: / t'♦.n``. "" ;� ,. i,,..' / :.,: / / ///// \\\W- xh?�' f TO ..,...., i t w {., \, . , -co _ ''�; ;"i_. A !.�i : I� '�%c';'i;: �1T \,-' E i• rl is13 it r ;__ \"� t ? t I F re z- ,,.. i`^ •0 i ,,.-. 3 �'1'_ '`Y I PANTED \,.E' g7f'.i:y:; M, -_ 3 i,+'�: > ; Yi�t'T�,. ,�' i<\-�? I :7 \ _ • r„ ate*` , Ce MIX' ck': CEILINGS : 1 a 333 ;?� � ? .:'C; A..:,i,ij\,:,u ?,.i 'o. i 'ANTED TM GOA / 5 FINE.Si ' i 0 , t 0 ,c_ , . •�\„ I'`- : 1;Z i ty` ?"....-• i!R r UNI-F,11--,17SECURELY 1C,•' ` A S 3' '.:.c,.,' i?�,.:`♦^CL., %ri'.LC. NItBE' 'S _ :•r•:`5 i' T 3it7f.?L*' x a,• w,r, 1�1 +LE . �. ,%PPLY .AND G .v.<, I: Irr';. ` Ly;;�•�y- Sys,' L 1.f<r.'7f t r �' )•'RE ,•.♦"" CENTERED•r'EI' V Diva: IN `"` y" t�M'!:\Wly t� r1 w't'\, w,`\`A\.. ::'... }��� �- » ...,.._ -- ,,,E`tM_,r .ar._.�.,-_ 1 �,..i i ti •,• ` \ , �• i...., 2 �-•'` ......................... \\ i t E\C-. • ti I _ J �h\�,,_„ ._,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,,, ,. y.• IT .'�: MASHER l:\•.. '-t.i?�i i+' ,,,\t LOCK .l';`l,. L , 1_,.\.r :,.K NI„ '�r ., •,:R x� Ji__. :. .Ii,:,.r•`LwiY�%a..'•�`• NEXT i �'Mr+ 4+i.,:'i \, o OO i`,J-.r L., , LOCK.NUTANL, ?' r'1L.a?`..u,ir- k`:.,,:.MI`"•.i`.7L-..: �� t.•?CS t -t"""c .,<•� <`+i t \ t 7 )ot,w'. i,x�r`et1rF ?3�'`'.,' ,:�,• •1"p E " ,,,, i\,,,'`M;2 ). `3.=.T`\Il.'.✓T'•� ,:,-•'.�.. :'•i' ~ .',\\ �',..y,-.T j,-`.,\,'• `..i ill 1... • w ;• (4-E.',0 �,•,`N t.',j". = „""„' H..0. C; -:$R -o4,8 },» . L„• . �' I T'"I`I i,:.r �\\ • a' : 3`\t„CtTii i --\:2 }x .,, \..;1�.+'E•".'` r; "•X..a f t a .. ... 1"' .M..., t<,.. irE I. S" H.0. it ?�.: "\,,. : �. , , I Mv,♦: , ch"r't' ; ^ti i. � ...............Twv.l..,wx� :gym. t 2 ..-,_-••'•.w-•,... INS` \..\,.�N: E_i... :'T!`kNi::' `�• 1 �,�`)ZL? , \ , �I� 1'~1`,i..' t.. -~w. 2 ..-`:i�- •IN .•� •t : it ' ...ta',^j,-°' c \. , 0 w ti . a„f. t- ti w \ ?-- 13 l_.+. X 1.. L ,?`\.,_\ PIPE. / O , .. ..�ti\?-..., "... .. ` AFF,E* a 3= -w.1 :. ,\� :.,,.r+". :.,*..- 3 "-- ..,. _ .. '= C-. 4. L, Yµ , " ` ', s a "r is ; �: Y » tf =� �� t j F '.4-I<% _ \~.! _•_' ii ..N ,.... .... `a:.:'v..'A-.=' E,.Ow..f\ N. :t'St,.F }'NASi`:` ::ASSEMBLY Et i >` (. w 0rvi> ., e I t4 J.- t<: - •�` IE , \ 'C" Z\ `-•' j '� =a'.. y:, It N 1 I L Wit••' I 000000000 II 1 € I Nal El \ ?`r Nib`: •M ♦ `21' i E.:AA'I- 1 RT i .A ;:n1, N' C Z ARE E is'; " .21.) ? E PER , ,. \N.:,, E BAR' I C.- £` i t .+" i .," _ 't F „-„ ,-i-` ' •.,,+• 1-1.$-,.. s,y��.....ry C - •• _N•, i i `\3,,. i ! ,. ,i• iii) H t•,,. u e -..t tam \,..,, 3 .` 4 '�' b ; \I i�" a 3 •,,., t..,.,t„.•• \.w t ,•., w,• t,.<< E I .\`>` ? `' H,.p, TOUT . i Zw L v ��r '"i t E ,^.."<, t per.,,. i >. :rw_, BAR ,''"rq` f `•'_ •.o'id,. �( C\..•' f mS k \„F Ask \�, ec,- ',,-B aE �irc,,� B UFF RT , Z �,.•�,1/4�,, i� i 's aau ,,,,\�� tv3 =aa••"' ;tet? ii3, "34,,' _� 3 I igak\ i 'i Q 3 t,, 00-• S 3 Lt ihL.A.,i.�'� a TEuw .,•`ve ,`a" .R` _,�` Rt-':-) , ,.<� ;A 3 t d; M1♦ .iv , • i t''' 3 h W to 3. u": „„,,'",t E , SC,LIE: NTS ' ,s,x E C: ? i •*°"� i r C 0 ea xi iles REVIEWED FOR CODE COMPLIANCE APPROVED SEP 05 2013 City of Tukwila BUILDING DIVISION RECEIVED - CITY OF TUKWILA AUG 1 22013 PERMIT CENTER N U I- W W O L co LL' < -o Ce w 0_ ZZ co W = cV 1 h - J CO J f rn � N O O C!) O U W W UI z LLB YJ Y 0Ce CD IX Cfl WOz . FVi LI U5 m(w CO U 0 0 L N o 0 CD 0 TW a) a) m co c 2 a) .O CD U -I hie 0 CSI z 03 u) 0_ (.0 (I) 0 J � WDu-1 < 0) 2 Z = W j W Vcf) Q J 4 ow Cl) CV(/) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: DETAILS SHEET A-8 OF 22 SHEETS DIVISION ONE/GENERAL REQUIREMENTS 00800 INSURANCE REQUIREMENTS General Contractor shall carefully examine the project documents and their contents, visit the site to examine the existing conditions, and fully inform him/herself of the laws, ordinances, and regulations affecting the contract and the work. Notify maurices and the architect immediately of any variations in the leased dimensions of the space from that shown on these documents. General Contractor work shall include all items implied or required to obtain the completed conditions contemplated by the contract and the. project documents. iwillobligations iPre-openingbolts Failure to do so not relieve the Contractor of any obl[gations with respect to the work. Indexed items of this specification are subject to separate bid in whole or in part by the controlling parties. Said parties reserve the right to reject any or all such bids. General Contractor shall be responsible for the total completion of the store as described and illustrated in these documents, excluding those items specifically deleted hereunder, or selected to be separately bid by the aforementioned parties, General Contractor is to verify the overall square footage of the space, by confirming dimension from lease line to lease line (i.e. center of wall, outside face of wall, etc,) and notify maurices'Project Manager of result within two (2) days of arriving on job site. General Contractor shall coordinate into project all items and materials furnished by maurices. All contractors shall guarantee work for a period of one year from time of maurices' acceptance against all defects of workmanship and material. Requests for repair or replacement by maurices or their agents within a one- year period from date of completion shall be binding upon said contractor(s) to secure correction of work. Definition; "Provide" means to "furnish and install." See sheet A-1 for breakdown of task responsibilities. 01040 COORDINATION r material removed from All rubbish, cartons, and miscellaneous discarded ate al shall beStockroom premises continuously during construction, After completion of construction, render premises clean and ready for installation of maurices' trade furnishings and miscellaneous items. General Contractor shall provide a storefront barricade if required by the Landlord. barricade furnished by Maurtces vendor. General Contractor to install first week on the job. See installation instructions with packaging. General Contractor shall provide black visqueen across storefront after punch inspection. 01.540 SECURITY .Area, Restroom,- In Stockroom areasurface-mount standards 10- 0" length) cut to lengths starting 6" above floor. For restrooms start standards 36" above floor and go to ceiling. For all other non -sales standards start 12" above floor and cut to length if necessary. Standards at sales areas and non -sales areas shall be mounted with every other standard anchored to partition blocking or masonry as the case applies. The to'drywall with#14 flatheadmachine remaining standards may be attached the dry a 1 " t 1/4" To ler brandtoggle bolt at each hole. Toggle bolts must (3 /2) withToggler gg gg align parallel with standards to prevent drywall popping. Utilize the following masonry anchor where attached to masonry. Both types shall be "Redhead" anchors by Phillips Drill Co. or equal. At solid masonry - Flathead #FS - 1452. At hollow block- #TG - 140 wing with 1/4" flathead bolt. Utilize at each hole on the standards. If metal studs (20 gauge minimum) are used, secure standards to studs with No. 14 flathead metal screws. Predrill 1 /8" hole into stud at each screw location. Refer to Division Six for additional areas requiring blocking. Coordinate these items with respective parties. Standards in sales area are based on continuous spacing modules of 24" o.c. with 2'-2" or 4'-2" sections of hangrod. Layouts noted for existing partitions may require modification to ensure standard attachment to existing studs or furring. Notify maurices of any proposed modification. Hanging Hardware - maurices shall furnish all garment hanging hardware required for store. maurices shall furnish all brackets at sales and non -sales areas. 05160 STRUCTURAL FRAMING SYSTEMS I. COVERAGES REQUIRED i � A. WORKERS COMPENSATION & EMPLOYER'S LIABILITY INSURANCE 1. In accordance with the laws of the State(s) of Washington 2. Policy to include Waiver of Subrogation in favor of Owner, its parent and subsidiaries where allowable by state law, B. COMMERCIAL GENERAL LIABILITY INSURANCE — All insurance required of Contractor shall be required for sub -contractors hired by Contractor. 1. LIMITS - Limits shall be no less than $1,000,000 combined single limit (CSL) for r n l injuryand property damageper occurrence/$2,000,000 bodilyt injury, aggregate per p p y g general a re ateproject/$2,000,000 liabilityaggregate. See D for g li g products umbrella limits. Limits for general liability and umbrella combined shall be no less than $5,000,000 per occurrence/aggregate. 2, OCCURRENCE FORM - Policy to be written on the occurrence form. 3. ADDITIONAL INSUREDS - Owner, its parent,subsidiaries and affiliated entities are to be included as Additional Insureds. a, Wherever Owner is listed it shall include itsarent and subsidiaries. p 4. POLICY TO INCLUDE a. PRODUCTS LIABILITY/COMPLETED OPERATIONS INSURANCE - Coverage to remain in force for a minimum of two years after completion of the job, or the length of the guarantee, whichever is greater. 1. Construction Trades Only - X,C,U, exclusion deleted b. CONTRACTUAL LIABILITY 1. Specifically insuring the liability and defense assumed under contract entered into between the Contractor and Owner 2. Contractor's policy to be primary and not contribute with any insurance carried by Owner. c. BODILY INJURY, PERSONAL INJURY AND PROPERTY DAMAGE d. WAIVER OF SUBROGATION in favor of Owner Contractor is responsible to ensure the security of all materials (new and removed), all items delivered to the job site, and all items considered salvageable. Charge backs will occur for lost items that are replaced. 01800. MATERIAL AND EQUIPMENT All details, accessories, or items necessary for a usable and complete project in accordance with the intent of the drawings and specifications shall be provided by the contractor(s). Contractor shall pay special attention to items that have long lead times (i.e., storefront glazing, Duroplex, transition strips, VCT, LVT, and ceiling tile material, etc.) and shall schedule accordingly to produce on time. 01700 CONTRACT CLOSE-OUT General Contractor shall obtain Certificate of Occupancy and complete all punchlist items for the project upon its completion and prior to departing site. *General Contractor shall provide complete architectural, mechanical, and electrical "as -built" drawings to the maurices construction representative at completion of work. No exceptions. Where any items from maurices' supplied package are unused (e.g., light fixtures), said items shall be left in store. An inventory of unused items shall be given to maurices Project Manager at time of store punch. General Contractor shall have premises professionally cleaned, including non -sales area, prior to turning space over to maurices. Non -sales area floor to receive 2 coats of wax. Contractor shall provide all necessary structural systems and members, hanging devices, and anchors throughout store, as required for safe support of all architectural, mechanical, electrical, and store fixture items shown on the drawings and specifications. Contractor shall follow landlord requirements for all structural support systems. 05720 RAILINGS AND HANDRAILS General conditions, as set out in the AIA Document A-201, modified by maurices, and the following specific conditions, shall pertain to all parts of the plans and specifications, as well as to all trades and contractors involved in this project. The plans for the storefront and interior have been prepared as a basis for construction purposes to secure adequate function and design. All drawings and specifications are inclusive. All lease conditions shall overrule any conflicting conditions with these contract documents. Layout shall be made in accordance with the drawings. Discrepancies or omissions in the drawings and specifications shall be brought to the attention of maurices for resolution, maurices shall furnish and General Contractor shall install all grab bars and accessories for barrier -free access in handicap fitting room. Landlord to furnish and install all grab bars and accessories for barrier -free access in restroom. e. POLICY FOR CONTRACTOR SHALL BE PRIMARY and not contribute with any insurance carried by Owner. f. CANCELLATION - Policy to be endorsed to require insurance company of Contractor to give no less than 30 days notice of cancellation, material change or nonrenewal to Owner. g. FINANCIAL RATING OF CARRIER - Insurance must be placed with a carrier rated A -VII or better by A. M. Best's C. COMMERCIAL AUTOMOBILE LIABILITY — to include all owned, non -owned and hired vehicles, with limit of liability not less than $1,000,000 combined single limit (CSL) per accident. D. UMBRELLA/EXCESS LIABILITY — Limits of no less than $4,000,000 per occurrence/ general aggregate/products aggregate following the aggregates of the primary policy. All coverage included in the underlying general liability policy must be included in the umbrella/excess. Contractor's umbrella policy to be excess of Contractor's general liability policy and umbrella policy must be endorsed to specify that Owner's umbrella policy will be excess of any other available insurance to Contractor and not contribute with it. II. CERTIFICATES OF INSURANCE - Certificates of Insurance shall be issued per below. A. Certificate to be issued as an emailed to: Marilyn Bergmann Mbergmann@maurices.com B. NOTICE OF CANCELLATION -- Certificate should specify that Insurer willprovide 30carpet p fY days notice of cancellation and/or non -renewal to Principal, C. COPIES OF ENDORSEMENTS TO BE PROVIDED WITH CERTIFICATE 1. Additional Insured — copies of the additional insured endorsement confirming that Principal is included as an Additional Insured. 2. Primary Insurance — endorsement specifying that Contractor's general liability insurance will be primary and not contribute with insurance carried by Owner. 3. Waiver of Subrogation — endorsement or copy of policy form for general liability and workers' compensation reflecting a waiver of subrogation in favor of Owner be . must pr confirmingthat the umbrella policy will respond on a 4. Umbrella — EndorsementComplete . primary and non contributory basis and not be excess over the Owner's insurance. 01010 SUMMARY OF WORK The General Contractor shall acquire all necessary permits. All work and materials shall comply with applicable codes and ordinances. Mechanical contractor shall communicate with demolition and drywall contractors that it is imperative to turn off all HVAC equipment or cover all return air grilles with filtering material prior to any work that may produce excess dust andManager contaminate HVAC systems. These filters are to be removed at the end of the dust -producing activity, Special attention shall be paid to blocking requirements in Division Six. Failure to comply with these requirements may result in reworking of these portions of project to conform. All studs and blocking for standards shall be on a spacing module. Modifications of any existing spaces may be required to meet standard spacing at sales area and non -sales area. If metal studs are used, they shall be 20 -gauge materials. Roof Opening penetration shall be by Landlord -approved roofing contractor only. Coordinate with Landlord. Any sprinkler modifications shall be by a landlord -approved sprinkler contractor only. Coordinate with Landlord. General Contractor shall provide Landlord with complete proof of insurance prior to start of construction. 01300 SUBMITTALS DIVISION TWO/SITE WORK 02050 DEMOLITION 05900 METAL FINISHES Paint all grilles, registers, pendant -mounted devices, etc. Paint to match adjacent finishes. Do not paint sprinkler heads. Where electrical plates and outlet covers occur in sales and fitting areas, use white switches, outlets and cover plates. DIVISION SIX/WOOD AND PLASTIC 06001 DESIGN INFORMATION Where demolition of existing construction occurs, contact maurices Project for instructions concerning the disposition of any salvageable materials. Where slab cuts are required, cuts shall be limited to minimum size possible. Patch cuts with concrete equal in thickness to and level with existing slab. Coordinate and acquire written approval for any such cuffs with Landlord prior to proceeding with work. Any and all demolition necessitated by the drawings shall be by General Contractor. DIVISION THREE/CONCRETE 03300 CAST -IN-PLACE CONCRETE General Contractor shall supply all non -sales area shelving, including shoe storage area, as noted on drawings. Pieces should not exceed 4'-O" in length. 06'150 WOOD -METAL SYSTEMS Install newpartitions as illustrated on drawings. All studs shall be installed as g indicated (see General Requirements) and shall be a minimum 20 -gauge metal or U.L. rated noncombustible construction grade kiln -dried Douglas Fir at contractor's option and as approved by regulatory agencies. Extend partition gypsum board and finishes down to floor slab and up to height designated by wall hatching or as detailed. Note that some studs in both new and existing partitions serve a dual role of partition supports and blocking for standards shown on floor plans and elevations. standard, andgarment hook blockinglocations on floor slab to locate blocking after gypsum board is installed. In addition to blocking required for standards, additional blocking is required at all fitting room hook and mirror locations, fitting room door bumpers, handicap fitting room bench, 2"garmentpole hook locations, at triple mirror locations, and at rest room accessory locations. 06200 FINISH CARPENTRY All concrete floor surfaces shall be level and free from waves. Finished slab elevations shall match finished elevation of adjoining mall slab. Slab cuts shall be avoided if at all possible. General Contractor to notify Construction Project Manager of any unusual or extreme subfloor conditions before any floor finishes are installed. Feather floor slab with floor stone at all mall tile/store tile and store tile/store transitions to create level transitions when floor finishes are complete. of actual a minimum of 4'-0" back from the with floor stonepoint FeatherMark transition. Also provide floor stone anywhere else slab is uneven. Grind and/orstud, remove slab as necessary for a smooth, flush, level slab. DIVISION FOUR/MASONRY -- NOT USED DIVISION FIVE/METALS 05001 DESIGN INFORMATION All workmanship and material shall be of the best quality. Where products are specifically called out, no substitutions will be allowed without written approval of maurices. Submit all required samples or requests for substitute materials directly to: maurices Incorporated Attn: Store Planning Department 105 West Superior Street Duluth, MN 55802 Phone: 218-727-843' Fax: 218-720-2138 6" x 6" samples of all finishes shall be submitted to maurices for approval prior to any substitute finishes being applied. 01500 CONSTRUCTION FACILITIES AND TEMPORARY CONTROLS No vertical grade laminates shall be used on any portion of this project. All wood grain and metal laminates and wood veneers must have grain running vertically. Plastic laminates to be called out by maurices shall be provided by the General Contractor, except on items furnished by maurices. 06300 WOOD TREATMENT Install the following hanging hardware: Sales Floor -10'-0" pre -finished surface -mount standards. (Standard to be mounted so Manufactures name is upright). Refer to drawings for placement height and length. All slots must align from standard to standard. See elevations for lengths of standards. Some locations will require G.C. to cut standards to the length. • Contractor to provide their own temporary phone and access to a fax machine for the duration of the project. arrangestoragecorrect Contractor to for off-site of all construction material if required• The maurices Agreement is herewith made a part of this specification in its entirety. All contractors involved in the construction of this space shall be totally aware of and shall comply fully with Landlord's construction criteria documents and all applicable provisions of the maurices Construction Agreement. Where required bycode, ordinance, orLandlord, materials shall be U.L. rated qby noncombustible or metal. Where required, fire coatings of materials may be utilized but in no case may visible sizes of members be increased without approval. b 31.11. ° REVIEWED FOR CODE COMPLIANCE APPROVED SEP 052013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKW -_ ILA AUG s Z 2013 PERMIT CENTER WCV W Co w I -- co -to O� WW �Zv- t N w00 =� r 0 w G 0, ore:o Ca LUN.14 LTC CO AUG 0 542013 U H = LOU Tt � ▪ Q j ino r cp2 O � Lo L(▪ CI) L ow IL: 0 0 0 in N L -C co 0 a - in 0 a) V C J a) 0 C as cv a) 'o 0 w h.. O N Z LL, SP. #408 J DL.]W0) Z�'S W0DUJ 0 _, 0 OoW V) N U) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: SPECIFICATIONS SHEET A-9 OF 22 SHEETS All joist and framing members, including structural wood members at the storefront, shall be U.L.rated noncombustible construction grade, kiln -dried Douglas Fir #2 or better, except where code or landlord requires metal, in sizes indicated. 06400 ARCHITECTURAL WOODWORK All doors equipped with a closer shall have its sweep period adjusted so the door from an open position of7 70 degrees, will take at least 3 seconds to move to a point 3" from the latch, measured to the leading edge of the door.47.10" The maximum pushing or pulling opening force of an interior door with a closer shall be 5 lbf. Fire doors shall have the minimum opening force allowed by the appropriate administrative authority. 08710 FINISH HARDWARE Construction LVT with In*StepTM Locking System Actual Size 7.28" W (185 mm) L (1196 mm) Performance Testing Slip Resistance/ASTM D 2047 ADA Compliant Smoke Density/ASTM E 662 <450, Passes Warranty 10 year limited commercial wear warranty. Please visit patcraft.com for the most current warranty information. Environmental Recycled cled Content Post -consumer - 39% Pre -consumer - 33% y Indoor Air QualityFloorScore® Certified LEED ScorecarMR4, IEQ4.3 Installation Storefront wall surfaces shall receive Duo lex wall coating. These materials must be installed per manufacturer's instructions and by a .manufacturer approved contractor. Duroplex must match control sample sent with material. Product manufactured by Triarch Industries, Inc., Houston, Texas (1- 800-537-6111). If sample is not received, contact maurices Project Manager. Existing "Duroplex" storefront wall surfaces shall receive new paint. Patch and repair the Duroplex® wall surface in accord with Triarch's recommendations. Clean all other wall sura e with light soap and water Approximate 5 days from order to ship date for material. General Contractor shall prep storefront Duroplex to receive high -gloss paint finish as follows 1. ApplyppDuroplex coating per manufacturer's instructions P 9 2. When Duroplex is dry, usinga random orbit sander,sandsurfaces all urfac s with one pass using 60 grit paper, followed by a sanding of all surfaces with one pass using 120 grit paper. 3. Clean all surfaces to be free of sanding dust. 4: Apply one coat of CAREFREE PRIME - ZALL PRIMER SEALER BY pp Y VISTAPAiNT Allow paint to cure for 3 hours. Apply second coat of the same primer. Allow to dry for 3 hours. 5. Apply first coat of 9900 PROTEC ALKYD EMULSION GLOSS BY ViSTA PAINT, tinted to match PMS 7472 Azure high gloss. Allow paint to cure for 24 hours. Apply final coat of the same paint. pp Y Wood base to receive stain per the finish schedule. Apply one (1) coat of stain and wipe off to expose wood grain. Fill holes with putty to match. 09950 WALL COVERINGS Wood trim; All fitting room door jambs and casing and other interior trim is to be supplied by maurices. Wood trim will be finished by the contractor in the following sizes. 3/8" x 2" Casing - at Fitting Room Doors (interior) 3/8"x 2"Casing - at Fitting Room Doors (exterior) 3/" MDF Door jamb - at Fitting Room Doors 3/" x 3/" Door stops - at Fitting Room Doors Door jamb material is sized to fit a 2 Y2" metal stud wall. General Contractor is to takeprecautions to build wall to proper thickness for proper fit of wood material.Install p p p p All corners to be mitered and seams lapped. No butt joints allowed. All seams to be at least 24" from corners. DIVISION SEVEN/THERMAL AND MOISTURE PROTECTION 07920 SEALANTS AND CAULKING Two-inch hooks for sales area garment hook poles are supplied by maurices and installed by General Contractor. 08800 GLAZING General Contractor shall furnish and install clean, clear tempered 112"glass. acing betweenglass panels. DO NOT use There is to be a maximum of 1/8" spacingp silicone at glass joints. See plans. General Contractor shall provide all necessary miscellaneous materials, tools, and labor fora complete and finished product. All work shall be as recommended by the manufacturer and trade industry. Order materials with sufficient lead-time to ensure delivery in time for scheduled installation. Storefront window glazing shall be safety glass as required by code. Refer to governing code for safety glass requirements in relation to height above finished floor, square footage, proximity to doors and walking surfaces and other requirements. 08810 GLASS with staggered joints 1/3 the length of the planks. • Product is a snap in place tile. No adhesive is required for instalation. • Floor must be clean and level with variation in surface elevation of less than 1/8" in 6feet or 3116" in 10 feet. ' Layout tile to insure last row is not less than 2" in width. • Maintain 'A" gap around entire perimeter of floor, including around columns, cabinet, etc. Install flooring in strict accordance with manufacturers instructions. Contact Patcraft for installation requirements. Patcraft PO Box 2128, Dalton GA 30722 800-241-4014 patcraft.com Non -sales floor vinyl tile Provide clear silicone bead 1/4" inside edge of Handicap fitting room mirror, sign holders, garment hang bars, handicap fitting room bench, door bumpers, doorstops, coat hook backplates, and behind all the wood casing, on both the inside and outside of the fitting openings. Silicone shall not be seen. Apply a bead behind carpet base in each fitting room and around inside perimeter of fitting room bank. DIVISION EIGHT/DOORS AND WINDOWS 08100 METAL DOORS AND FRAMES Furnish and install 2' x 5' x IA" silver float plate glass mirrors with polished edges in standard fitting rooms, and 3'-O" x 5'-0" x14" silver float plate glass mirrors with polished edges in handicap fitting room. Mirror shall be installed with double- coated urethane foam tape as manufactured by 3M #'1008 or equal. G.C. to mount fitting room mirror at 1'-0" AFF. Utilize a continuous, clear silicone perimeter bead behind all fitting room mirrors. Apply bead 1/4" inside of mirror edge as detailed on drawings. Silicone bead shall not be visible at edges of mirror. DIVISION NINE/FINISHES 09250 GYPSUM WALLBOARD General Contractor shall protect completed finishes from construction damages. All walls shall be primed with one coat of Benjamin Moore All -Purpose Fresh Start acrylic primer, supplied by General Contractor prior to the installation of wall coverings. See section 9900. Where vinyl or other wall coverings occur adjacent to laminate or other similar wall materials, said covering shall be wrapped under this adjacent surface to permanently secure its edges. If wall covering cannot be wrapped under adjacent material, apply a thin bead of silicone to prevent wall covering from peeling back. Vinyl composite tile in non -sales area, restroom, and miscellaneous areas shall be Armstrong Imperial Texture Excelon Tile No. 51899, Cool White, size 12" x 12" x 1/8". Tile No. 57506, and accent color Colorado Stone, size 12" x 12" x 1/8" as manufactured by Armstrong World Industries. Install Cool White tile in all non -sales areas. In Restroom and corridor areas only, install at a ratio of 3 cartons of Cool White tile tol carton of Colorado Stone tile. The accent color Colorado Stone is to be randomly mixed into the Cool White color. The Cool White tile is to be installed with the grain running parallel to the storefront and the Colorado Stone is to be installed with grain running perpendicular to storefront. Install tile with tile manufacturer approved mastic. Contractor to apply (2) coats of wax on completed floor. All metal frames shall be of highest -grade materials, primed and ready to receive painted finish. Snap -in type metal frames are to be used at all non -sales doors, unless already existing or special ratings are required. 08200 DOORS Patch and repair all existing gypsum board or similar surfaces ready to receive new decorative finish as noted on the drawings. Where necessary, remove existing wood and/or similar trim and existing decor items prior to patching. All miscellaneous wood doors shall be solid core unselect birch unless noted otherwise on the drawings. All fitting room doors are supplied pre -milled for hardware and with the hardware for field assembly included, unless noted otherwise. See door schedule. 08400 ENTRANCES AND STOREFRONTS New custom wood storefront doors with hardware provided by maurices and painted and installed by General Contractor. General Contractor shall provide Stylmark framing system in Satin Natural finish #020 (or equal, as approved by maurices). General Contractor shall provide Stylmark 2" x 2" Square Glass Clips. Style #510571 Finish: Satin Natural #020 Stylmark Inc. Provide 5/8" gypsum board (screw applied) on both sides of all new partitions and overhead enclosure systems, except at demising partitions where gypsum board shall be applied only to the side of this leased premises. Carry 5/8" security gypsum board from overhead modular acoustical panel system line to metal deck at all demising and fire partitions, including storefront, to provide total security and separation of maurices' leased space from adjacent spaces. Tape and float all partitions to a smooth flat finish according to manufacturer's directions and specifications ready to receive paint or decorative coverings. Provide metal -taping beads at all jambs, corner openings, and elsewhere where gypsum board joins to other materials. Use only USG #801-A metal trim. Where vinyl is used for wall covering, gypsum board surface must be prepared flush and smooth. No exceptions will be accepted. General Contractor shall prepare existing gyp. board wall surfaces to accept new finishes. This may include new layer of gyp. board, skim coating surface or other acceptable method agreed to by maurices Project Manager. General Contractor shall be responsible to patch and repair any damage to the L.L. neutral piers or neutral band due to maurices' construction process. Contact the mall representative. 09500 ACOUSTICAL TREATMENT Investigate leased area for existing vinyl asbestos or composite tile. If existing is composite tile, patch, and repair tile floor to first-class condition where not covered by carpet. Utilize a matching product and a tile manufacturer approved mastic. If an asbestos product, notify maurices for further instructions. Where required by code and/or ordinance, restroom shall receive a sheet vinyl floor material conforming with said regulation. Material shall match coloration of V.C.T. used elsewhere in non -sales areas, shall have a 4" self -cove base with top cap, and shall be applied with a tile manufacturer approved mastic. Where code requires, restrooms shall receive FRP (fiberglass reinforced plastic) with a 4" vinyl base on all walls. The FRP shall run up walls to 4'0" AFF. Panels are to be Marlite or equal, color white. Panels are to be installed using liquid adhesive with "division" (butt -joint) and "outside/inside corner" trim pieces between panels and "edge" (cap j -mold) trim pieces along top of panels. All trim pieces to be extruded PVC, color white. Vinyl composite the areas shall receive 4" Johnsonite cove base, # 47 Brown. All corners of rubber base shall be back scored at corners. GENERAL CONTRACTOR MUST ALLOW A TWO-WEEK LEAD TIME. 09690 TRANSITION STRIPS General Contractor shall install all partition decorative coverings indicated with a first-class washable mastic and/or supplemental attachment method as supplied by Contractor and as recommended by the respective manufacturers. However, no exposed trim or attachment devices will be allowed. No heavy-duty "clear" adhesive will be accepted. All wall coverings must be allowed manufacturer specified booking time following adhesive application (place wall coverings in a bag to prevent drying out during booking process). Contractor shall double cut vinyl wallcovering to assure well -matched edges, whenever possible. Utilize sharp, accurate cuts throughout. Cuts at corners shall only occur at inside corners. All outside corners must be wrapped. Wall covering to extend beyond edge of any adjacent wood trim, with wood trim installed over wall covering. DIVISION TEN/SPECIALTIES 10400 IDENTIFYING DEVICES P.O. Box 32008 Minneapolis, MN 55432 800-328-2495 Header #110360 Sill 4" #110482 - 6" #110481 Anchor #110358 Column Base 4" #110227-6" #110269 Anchor Plate 4 " #410458-6" #410509 Glass Clips #510571 Finish: Satin Natural#020 General Contractor shall provide all necessary miscellaneous materials, tools, and labor for a complete and finished product. All work shall be as recommended by the manufacturer and trade industry. Order materials with sufficient lead-time to ensure delivery in time for scheduled installation. 08700 HARDWARE MISCELLANEOUS MERCHANDISING SIGNS Maximum brightness shall not exceed 100' lamberts. No exposed raceway ballast boxes or transformers will be permitted. Sign company names or stamps shall be concealed, except as required by local code. General Contractor shall provide store identification sign at rear security door, if not existing. Lettering shall be 3 -inch high Helvetica medium at 6'0" in black or white to best contrast door color or per mall requirements. 10410 FRAMING DEVICES General Contractor shall furnish and install transition strips for all mall tile/store tile transitions as manufactured by Schluter -Systems. Product to be: "RENO - V", Color Satin anodized aluminum. Available through: Schluter -Systems L.P. 194, Pleasant Ridge Road Plattsburgh, NY 12901-5841 Phone: 1-800-472-4588 Fax: 1-800-477-9783 e-mail: infoschluter.com GENERAL CONTRACTOR MUST ALLOW A TWO-WEEK LEAD TIME. General Contractor shall furnish and install a vinyl transition strip #177, color #110, brown, at sales/non-sales area door as manufactured by Roppe, Fostoria, Ohio, Roppe: 1-800-537-9527 Installation of new acoustical panel ceiling system shall be accomplished with the highest trade standards. Origin point(s) of grids shall be as indicated on drawings. CEILING PANELS Sales Area Ceilings USG 2x4 (Two/24 Panels (Second Look)), Radar ClimaPlus Illusion #2842 W/ SLT Edge. Color: "Mist #053" SUSPENSION SYSTEMS Sales Area Ceilings All fitting room doors come complete with hinges, latch sets, and door handles provided by maurices) for field installation by General Contractor. maurices provides all other fitting room door hardware as shown in the drawings and door schedule. All fitting room door hardware to be installed with "lock-tite" on mounting screws. Finish hardware as shown in these documents shall be installed in accordance with the manufacturer's specifications, General Contractor shall furnish and install Hagger BBI199 surface mounted 4- 1/2" x 4-1/2" ball bearing stainless steel hinges w/ non -rising removable pins (or equal) on rear exit door if not existing. General Contractor shall install U -Change locks at storefront door as furnished by maurices. maurices' personnel shall rekey after construction acceptance (or sooner as required). Poster grip frames used on fitting room doors are furnished pre -assembled by maurices and installed by General Contractor at 5'-O" AFF. Install plumb, straight and level. 10520 FIRE EXTINGUISHERS USG Donn DXIDXL Acoustical Suspension System. Color #053 Mist 09650 RESILIENT FLOORING All fire extinguishers shall be supplied and installed by General Contractor. Fire extinguishers are a dry chemical 5# - ABC or equal. Mount top of extinguishers at not more than 5'-0" AFF per National Fire Code. Coordinate locations in store local and state building/fire officials. Sales floor vinyl tilewith Product Specifications Style Name CLICK REFRESH Style Number 1600V REVIEWED FOR CODE COMPLIANCE APPROVED SEP 052013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWiLA AUG 1Z 2013 PERMIT CENTER F- W W 0 ce 00 LID F- 0 00 00 W 0_Z ZT- 2 Co D D CV 0 l AUG 0 6-2013 0 M O I -- w U J J ZU Q Cf} -x- LU W u, O o Coc O D° u.IU co 2 =2�LJ Uw < CT) Zr, 1--O LU Nam o r 0 CV W z ft co L.. < w WCO =Q Z � WuJD VO—I E F- u) ©a V)NC/) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: SPECIFICATIONS SHEET A-1 0 OF 22 SHEETS DIVISION ELEVEN/EQUIPMENT 11090 POS EQUIPMENT General Contractor shall be responsible to hook-up modem and router supplied by maurices on POS equipment board in non -sales area. General Contractor to coordinate with Scott Brickles at maurices at 218-727- 8431 ext.3151 for installation of the POS router and modem. DIVISION TWELVE/FURNISHINGS 12920 RESTROOM ACCESSORIES Landlord shall furnish and install a single 24" x 36" mirror with J -channel trim. oil toilet tissues dispenser and a General Contractor shall install wall standards over the water closet as shown on plans. Maurices shall provide two (2) 14" x 26" x 1" finished shelves and req'd brackets in each restroom. DIVISION THIRTEEN/SPECIAL CONSTRUCTION PHONE General Contractor shall furnish and install a 66 punch down block for the phone service along with all phone jacks (as shown on E-4), wiring, connections and cover plates. EAS General Contractor to contact Sensormatic Project Manager for installation instructions of security system. Sensormatic Contact Information - For scheduling issues: Robin Jensen 715-688-2180 riensen@adt.com For installations issues: Mark Wakeman 860-583-0462 mwakeman@tycoint.com DIVISION FOURTEEN I VANILLA SHELL — NOT USED REVIEWED FOR POE COMPLIANCE APPROVED SEP 0 5 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TtKWILA AUG 1 2 2013 PERMIT CENTER W N W O ceI O o • (/) WW CI Z -r Z 1. 2 co I— 1' D co J — N ✓ AUG 0 6 -2013 r M "ct 0 w J . Z5 - I- WLu ?�ILO oci C>e- 0O H_0z0 Ca vt co 0). rC=TCO Lr) U) U, LL 0 w I- 2 0 2 ce vi 0 E 8 U 0 E L U a) 0 0. z 0 a) V C CD a) 0 0 r Q w N Z (f) a) (021_1 oJ Q Wa LU =Q ajz�� W w- o w Eli w (!) N C/) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC / MD -SS / CJ APPROVED BY : XX REVISIONS: SPECIFICATIONS SHEET A-11 OF 22 SHEETS SALES AREA SALES AREA SALES AREA 50% 50% DECORATIVE JUNO TRACK - WH N/A 1 CIRCUIT BASIC TRACK B JUNO T69OWH LED18PAR38NFL25 / DISPLAY C JUNO TRAPEZIA T635 -16-I' MH/ MONO POINT MOUNT R4OWH LED 16 PAR 30 TRACK HEAD, WHITE F JUNO - TM12OWH + TM510INH MHC-10/U/M/3K PERIMI= rE . WALLINASH TRACK FIXTURE, WHITE FINISH it" MASTER LIGHTING SWITCH BANK NOTES: THESE DRAWINGS ARE DIAGRAMMATIC - REFER TO ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. BRANCH CIRCUITING CONNECTION #12 AWG PER PHASE AND NEUTRAL (WHERE REQUIRED) AND 20 AMPERE CIRCUIT BREAKER, UNLESS OTHERWISE NOTED. PROVIDE QUANTITY AND SIZE SWITCH CONDUCTORS A5 REQUIRED TO MAKE SYSTEM FULLY OPERATIONAL. IT IS THE. ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL EXISTING CONDITIONS AND TO PROVIDE ANY ADDITIONAL MATERIALS ETC. AS REQUIRED TO COMPLY WITH MALL CRITERIA AND ELECTRICAL SPECS AND DRAWINGS AT NO ADDITIONAL COST TO MAURICES. THE ELECTRICAL CONTRACTOR TO NOTIFY MAURICES' CONSTRUCTION DEPARTMENT ON ANY CONFLICTS WITH LIGHTING. PLACEMENT WITH ANY OTHER ITEMS SUCH AS DUCTS, SPRINKLER SYSTEM, DIFFUSERS, ETC.. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A FIRST ALERT SMOKE DETECTOR, BATTERY OPERATED OR APPROVED EQUAL. ALL EMERGENCY BALLAST OF EMERGENCY LIGHT FIXTURES SHALL BE WIRED AHEAD OF THE SWITCH AND/OR LIGHTING CONTACTOR AND THE REMAINING BALLAST SHALL BE WIRED NORMALLY AS REQUIRED AND MADE FULLY OPERATIONAL. (TYPICAL) A-1 (EM/NL) TO A-15 (EM) AHEAD OF SWITCHING (EM/NL) GENERAL NOTES: 1. THE ELECTRICAL CONTRACTOR SHALL NOTIFY THE ARCHITECT/ ENGINEER OF ANY CONFLICTS PRIOR TO START OF INSTALLATION. 2. THE ELECTRICAL CONTRACTOR SHALL ARRANGE FOR ALL INSPECTIONS WHEN THEY BECOME DUE AND SHALL NOT COVER ANY WORK PRIOR UNTIL APPROVED BY THE INSPECTION AUTHORITY. 3. THE INFORMATION PRESENTED ON THESE DRAWINGS 15 DIAGRAMMATIC IN NATURE. IT DOES INDICATE THE GENERAL DESIGN AND ARRANGEMENT OF CIRCUITS, OUTLETS, EQUIPMENT, SYSTEMS ETC. PROVIDE ALL MATERIALS AND LABOR FOR COMPLETELY FINISHED AND OPERATIONAL SYSTEMS. 4. REFER TO LATEST ARCHITECTURAL DRAWINGS FOR: EXACT WALL LOCATIONS, DIMENSIONS AND CONFIGURATIONS, DOOR SWINGS FOR SWITCH LOCATION VERIFICATIONS, LIGHTING PLANS FOR VERIFICATIONS OF LIGHT FIXTURE LOCATIONS. 5. ELECTRICAL CONTRACTOR SHALL VERIFY ALL ELECTRICAL EQUIPMENT LOADS PRIOR TO ROUGH -IN AND SHALL NOTIFY ENGINEER OF ANY DISCREPANCIES THAT EXIST. 6. ELECTRICAL CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY ALTERATIONS REQUIRED BY THE OWNER, ARCHITECT OR FIELD CONDITIONS. 1. ALL NEW ELECTRICAL EQUIPMENT BEING INSTALLED SHALL HAVE THE APPROPRIATE UNDERWRITERS LABORATORIES, INC. (UL) LABEL AND SHALL CONFORM TO THE LATEST INDUSTRY STANDARDS. 8. ELECTRICAL CONTRACTOR SHALL MAINTAIN ALL WORKING CLEARANCES FOR ALL ELECTRICAL EQUIPMENT AS PER NEC REQUIREMENTS. 1. ALL WORK SHALL COMPLY WITH LATEST EDITION OF THE NATIONAL ELECTRICAL CODE (NEC) AND ALL LOCAL AND STATE BUILDING CODES AND ADOPTED ORDINANCES, AND REQUIREMENTS OF THE UTILITY CO. 10. ELECTRICAL CONTRACTOR SHALL CLEARLY MARK ALL JUNCTION BOX COVERS TO INDICATE THE CIRCUITS WITHIN THE JUNCTION BOX. 11. AT THE COMPLETION OF ALL ELECTRICAL WORK, THE ELECTRICAL CONTRACTOR. SHALL PROVIDE COMPLETE AND ACCURATE, TYPED PANELBOARD DIRECTORIES. 12. REFER TO ARCHITECTURAL DRAWINGS FOR ADDITIONAL DETAILS. 13. ® INDICATES HUBBELL DUAL TECHNOLOGY CEILING MOUNTED OCCUPANCY SENSOR (#ATD500C), SET TO MAXIMUM TIME DELAY TO SWITCH OFF. 14. ® INDICATES HUBBELL DUAL TECHNOLOGY WALL MOUNTED OCCUPANCY SENSOR (#AD12T1WI), SET TO MAXIMUM TIME DELAY TO SWITCH OFF. 15. SALES NIGHT LIGHT (NT -LT, NL) FIXTURES SHALL BE CONNECTED TO CIRCUIT A-41. EXIT SIGNS AND EGRESS LIGHTS (AS APPLICABLE) SHALL BE CONNECTED TO CIRCUIT A-1. 16. C INDICATES JUNO TRAC-MASTER TRACK -MOUNTED CURRENT LIMITER. ALL TRACK LIGHTING ON THIS CIRCUIT SHALL BE CONNECTED TO LOAD SIDE OF CURRENT LIMITER. LIGHTING CONTROL NOTES SIGN TIME CLOCK SETTING. STOREFRONT SIGNS IN STRIPS, DOWNTOWNS, ETC (NON -MALLS) TIME CLOCKS SHOULD BE SET FOR SIGNS TO TURN ON EVERY DAY AT 3:00 P.M. AND TURN OFF A HALF HOUR AFTER CLOSING. IN MALLS, SIGN AND STOREFRONT LIGHTING, ALL TO BE ON TIME CLOCK. AND SET PER MALL HOURS. TO BE VERIFIED WITH MALL. NEMA 1 ENCLOSURE A-16 ; TWO HOUR /9— OVERRIDE SWITCH TORK PROGRAMMABLE EW120B TIME CLOCK. TO BE SUPPLIED BY MAURICE5, INSTALLED BY E.G. NEMA 1 ENCLOSURE CONTACTOR 'TC" A-3 A-5 A-7 I A -q LINE SIDE 6 POLE, 600V RATED CONTACTOR NORMALLY OPEN, A-11 ELECTRICALLY HELD CLOSED. CONTROL BY LOAD SIDE SWITCH TCI' SINGLE -POLE SWITCH TO OPERATE \i) LIGHTING CONTACTOR. 0 b�° CONTACTOR "A" 1 1-11. LOAD SIDE LINE SIDE A-33 4 POLE, 600V RATED A-37 CONTACTOR NORMALLY OPEN, ELECTRICALLY HELD CLOSED. CONTROL BY SWITCH 'TC2' SINGLE -POLE SWITCH TO OPERATE LIGHTING CONTACTOR. br° TWO HOUR OVERRIDE SWITCH TORK PROGRAMMABLE EW120B TIME CLOCK. TO BE SUPPLIED BY MAURICES, INSTALLED BY E.G. A-35 A-31 LINE SIDE 4 POLE, 600V RATED CONTACTOR NORMALLY OPEN, ELECTRICALLY HELD CLOSED. CONTROL BY —Y-- ' SWITCH TC2 LOAD SIDE SINGLE -POLE SWITCH TO OPERATE LIGHTING CONTACTOR. /is r0 0 1 1-1 CONTACTOR "C" I A-17 A-11 1 I A-21. A-23 I -H A-29 LOAD SIDE CONTROL BY SWITCH 'TC2' --a —1 LINE SIDE —t —t 8 POLE, 600V RATED CONTACTOR NORMALLY OPEN, ELECTRICALLY HELD CLOSED. LIGHTING CONTROL DIAGRAM ADJACENT TENANT (N.I.C.) BLACK WHITE RED —0 LAMP A.G. BALLAST BLUE BLUE BLUE BLUE LAMP — a *LAMP G< BLUE/WHITE RED/WHITE RED YELLOW *AC/EMERGENCY COMMON EMERGENCY BALLAST ORG (120V OR 341V) BLACK WHITE WHITE/BLACK 4 uxl CONNECTOR = > 0 IBIS/CHARGE INDICATOR THREE LAMP INSTANT START BALLAST SWITCHED OR UNSWITCHED LINE } ©SWITCHED COMMON 0 SELECT PROPER VOLTAGE LEAD. CAP UNUSED LEAD. © DO NOT MATE CONNECTOR UNTIL INSTALLATION IS COMPLETE AND AC POWER 15 SUPPLIED. © LAMP SELECTOR LEADS - REFER TO INSTALLATION INSTRUCTIONS. LAMP OPERATION SECTION FOR VARIOUS OPTIONS. ® CONNECT BLUE/WHITE AND RED/WHITEWIRES TOGETHER. L.I4T SC -4!U LE f SYM DESCRIPTION LAMP REMARKS A JUNO TRACK - WH N/A 1 CIRCUIT BASIC TRACK B JUNO T69OWH LED18PAR38NFL25 TRACK HEAD WITH FLOOD LAMP C JUNO TRAPEZIA T635 -16-I' MH/ MONO POINT MOUNT R4OWH LED 16 PAR 30 TRACK HEAD, WHITE F JUNO - TM12OWH + TM510INH MHC-10/U/M/3K PERIMI= rE . WALLINASH TRACK FIXTURE, WHITE FINISH G LIGHTOLIER S2420U-120/21-T- ADV/8O38-GLNI/1951 PHILIPS PLT421/4/835/4P FLUORESCENT DOWNLIGHT H MERCURY 54E-240-BIAX-16-ELB-UNI-EM PLL401N/35K/RS 2X2 FLUOR TROFFER W/ 3" DEEP CFS I PARABOLIC LENSE Y4/ EMERG BALLAST -1 MERCURY MM132-OGT/ST-GELS-UNI 2/F032/135/ECOt8 16" FLUOR STRIP K MERCURY MM132-OCT-C-ELB-UNI 1/FO32/135/ECOt8 48" FLUOR. STRIP L MERCURY 54E-240-13IAX-1b-ELB-UNI PLL40W/35K/R5 2X2 FLUOR TROFFER W/ 3" DEEP CELL PARABOLIC LENSE M METALUX 2E1:730X-3325361-UNI-OS 3/F032/735/ECOtS 2X4 FLUOR TROFFER W1 3" DEEP CELL PARABOLIC LENSE F METALUX 2EP3GX-3325361-2TTV- FBP24OH/2L-05-0TP2X32T8UNV ISNSC-U 3/F032/135/EGOTS 2X4 FLUOR TROFFER W/ 3" DEEP CELL. PARABOLIC LENSE W/ BA i i tT<Y PACK 0 HIGHLITES NAEP -PLED -R* LED EXIT SIGNS IN/ SELF CONTAINED BATT PACK 5 3 LIGHT WALL BRUSHED NICKEL FINISH W/ WHITE OPAL GLASS ITEM # 664G1 3 STANDARD BASE, FROSTED, TORPEDO, 60 WATT MAX VANITY LIGHT ABOVE RESTROOM MIRROR @ 6'-8" AFF. T HL-90-1A1H LAMPS INCLUDED 2 HEAD SELF CONTAINED EMERG LT V MERCURY MM132-OGT-GELS-UNI-EM 1/F032/135/ECOtE 48" FLUOR. STRIP EMERGENCY BALLAST W MERCURY MM132-OGT/ST-C.-ELB-UNI-EM 2/F032/135/ECOt8 16" FLUOR. STRIP EMERGENCY BALLAST z VIDAL 12260-010 CLEAR - 1 LIGHT PENDANT 1/1001N/A11 E26/120V MOUN rEL) AT 8'-6" TO CENTER OF FIXTURE AA ET2 E95160 -1005N (4)-GU24 SALES AREA PENDANT LIGHT BB HANGER FIXTURE (CUSTOM) 1/100MB/GAP CASH WRAP / FITTING RM PENDANT LIGHT GC BELLACOR # 64261S 5 -light Eurofase Lighting Melody Chrome 16" DIA, HOT SPOT PENDANT LIGHT (TRIO) 3 / 40 WATT GI BULBS FIXTURE TYPES "G, H, J, K, L, M, P, IN, V" ARE DUAL VOLTAGE (120 OR 211) • C13) n n A-24' A-3 THRU TC1 A-5 THRU TC1 MASTER LIGHTING SWITCH BANK THRU TC2 A-35;35;41- THRU TC2: M M M 51 331 V (EM/NL) 1111111liil i m m ADJACENT TENANT (N.I.G.) A-15 (EM) AHEAD OF SWITCHING SEE NOTES 41 ;SEE NOTES 411 33 A-7 THRU TC1 STOREFRONT SIGN A-19 4 THRU TC2 INDICATES AMPERAGE (EM/NL) A-37,01 THRID TC2 (EM/NL) (EM/NL) LIGHTING PLAN SCALE: 1/4" = 1'-O" COL ADJACENT TENANT (N.I.0.) EXISTING MALL CONCOURSE (N.LG.) STOREFRONT LIGHTBOX b 13.2, 0 RECEWED CITY OF TUKWILA AUG i 2 2013 PERMIT CENTER 0 1' 5' 5' 10' 2' 4' SCALE:34' =1'-0" W (V WCD ) 15- " L ct O-o aZ � L Zco 00 CO( -NB �2N W co cp 0 J r J 0 Co O E = 8 O 8. J 7-1 L CS Zjry Zd:Fev1 W - Ceo C° E c.� O Wva W O Z '. Z=�It) �y In �or-� Zce)(0 0 W co cc 1- .1E CD W ti o t� (I) N W CI) a. a) w J _ J 0J Q L.II.12 1211 DW 1„..._-1 = Q wz, WOW UOJ EO o 0 < w cocn (,) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: LIGHTING PLAN SHEET E-1 A.): 22 SHEETS NOTES: THESE DRAWINGS ARE DIAGRAMMATIC - REFER TO ARCHITECTURAL DRAWINGS FOR EXACT DIMENSIONS. BRANCH CIRCUITING CONNECTION #12 AWG PER PHASE AND NEUTRAL (WHERE REQUIRED) AND 20 AMPERE CIRCUIT BREAKER, UNLESS OTHERWISE NOTED. PROVIDE QUANTITY AND SIZE SWITCH CONDUCTORS A5 REQUIRED TO MAKE SYSTEM FULLY OPERATIONAL. IT IS THE ELECTRICAL CONTRACTOR'S RESPONSIBILITY TO FIELD VERIFY ALL EXISTING CONDITIONS AND TO PROVIDE ANY ADDITIONAL MATERIALS ETC. AS REQUIRED TO COMPLY WITH MALL CRITERIA AND ELECTRICAL SPECS AND DRAWINGS AT NO ADDITIONAL COST TO MAURICES. THE ELECTRICAL CONTRACTOR TO NOTIFY MAURICES' CONSTRUCTION DEPARTMENT ON ANY CONFLICTS WITH LIGHTING PLACEMENT WITH ANY OTHER ITEMS SUCH AS DUCTS, SPRINKLER SYSTEM, DIFFUSERS, ETC.. ELECTRICAL CONTRACTOR SHALL PROVIDE AND INSTALL A FIRST ALERT SMOKE DETECTOR, BATTERY OPERATED OR APPROVED EQUAL. ALL EMERGENCY BALLAST OF EMERGENCY LIGHT FIXTURES SHALL BE WIRED AHEAD OF THE SWITCH AND/OR LIGHTING CONTACTOR AND THE REMAINING BALLAST SHALL BE WIRED NORMALLY AS REQUIRED AND MADE FULLY OPERATIONAL. (TYPICAL) DUCT SMOKE DETECTORS ARE TO BE CONNECTED TO REMOTE TEST STATIONS AND MALL FIRE ALARM SYSTEM. COORDINATE ALL FIRE ALARM SYSTEM REQUIREMENTS WITH LANDLORD PRIOR TO BID. TO A-10 ELECTRICAL CONTRACTOR RESPONSIBLE FOR ALL PHONE SYSTEM INSTALLATION INCLUDING FINAL HOOK-UP TO PHONE COMPANY JACK MANAGER'S DESK PHONE I 4 WIRE LINE (TYP. ALL RUNS) 7-21/4" 12" SALES FLOM pHote rosea LHRH "rare E.G. TO MAKE CONNECTION FROM "PUBLISHED" JACK TO b6 PUNCH DOWN BLOCK NOT REQUIRED IF STORE HAS E ILS WN PUNCH DOBCK HONE ANE UNPUBLISHED LINE #2 _— — SEE SHEET E-4 FOR JACK LOCATION (TYPICAL Of 2) rosl9iimp - `% ACCESS PANEL GASHWRAP 4 WIRE LINE (TVP. ALL RUNS) #2, DATA LINE, SEE CASHWRAP ELEVATION FOR LOCATION #1, VOICE LINE, SEE CASHWRAP ELEVATION FOR LOCATION (1) JACK AT CARD TABLE, SEE E-4 FOR LOCATION (1) FOR LOCATION MANAGERS DESK, EL JACKS L— D5L MODEM MANAGERS DESK PHONE NONSALES PHONE DSL MODEM, SUPPLIED AND EXTENT OF PHONE COMPANIES INSTALLED BY PHONE COMPANY WORK, ALONG WITH CONNECTION TO DBL MODEM. 2—LINE PHONE DETAIL T-2 1/4" 12" PO5 #3 UNIT A UNIT E UNIT B UNIT D ELECTRICAL ACCESS PANEL LOCATION 1. FIXTURE VENDOR PROVIDES TWO 4-PLEX RECEPTACLES AND ONE POW4R BAR FOR EACH TERMINAL (ONE GENERAL 4-PLEX, ONE ISOLATED GROUND (ORANGE) 4-PLEX LABELED "POS ONLY" W/ MIN. OF 10 FEET OF WIRE WITHOUT PLUGS ON THE END. 2. ELEC. CONTRACTOR SHALL PROVIDE (1) IN -FLOOR J -BOX (120 VOLT CIRCUIT) AND (1) IN -FLOOR J -BOX (DEDICATED POS CIRCUITS) AND HARDWIRE EASING WIRES FROM CASHWRAP TO APPROPRIATE J -BOXES. 3. ELEC. CONTRACTOR SHALL PROVIDE A LOCKOUT AT PANEL FOR EACH ISOLATED CIRCUIT FOR THE P05. 4. ISOLATED GROUND SHALL NOT CONNECT TO CONDUIT OR J -BOX. ADJACENT TENANT (N.I.C.) 1. FIXTURE VENDOR PROVIDES TWO 4 -FLEX RECEPTACLES AND ONE POYeR BAR FOR EACH TERMINAL (ONE GENERAL 4-PLEX, ONE ISOLATED GROUND (ORANGE) 4-PLEX LABELED "POE ONLY" W/ MIN. OF 10 FEET OF WIRE WITHOUT PLUGS ON THE END. 2. ELEC. CONTRACTOR SHALL PROVIDE (2) IN -FLOOR J -BOX (120 VOLT CIRCUIT) AND (2) IN -FLOOR J -BOX (DEDICATED POS CIRCUITS) AND HARDWIRE EXISTING WIRES FROM CASHWRAP TO APPROPRIATE I -BOXES. 3. ELEC. CONTRACTOR SHALL PROVIDE A LOCKOUT AT PANEL FOR EACH ISOLATED CIRCUIT FOR THE P05. 4. ISOLATED GROUND SHALL NOT CONNECT TO CONDUIT OR J -BOX. UNIT A UNIT B UNIT G UNIT D E.G. IS RESPONSIBLE FOR RUNNING WIRING AND FINAL ELECTRICAL HOOK-UP AFTER UNITS ARE SET IN PLACE AND LEVELED. E.G. IS RESPONSIBLE TO DRILL ANY ADDITIONAL HOLES INSIDE DESK TO ACCOMMODATE THE ELECTRICAL RUNS AS REQUIRED. POS #3 ORANGE FOURPLEX BOX. (ISOLATED GROUND WIRE) (TYPICAL EACH POE LOCATION) -ELEVATION 120 VOLT TO FOURPLEX OUTLET BOX E.G. SHALL PROVIDE CONDUIT AND HUBBELL IN -FLOOR JUNCTION BOX (WITH GROUND). E.G. 15 RESPONSIBLE FOR RUNNING WIRING AND FINAL ELECTRICAL HOOK-UP AFTER UNITS ARE SET IN PLACE AND LEVELED E.G. 15 RESPONSIBLE TO DRILL ANY ADDITIONAL HOLES INSIDE DESK TO ACCOMMODATE THE ELECTRICAL RUNS AS REQUIRED. VOICE PHONE JACK, MOUNTED ON SIDE PANEL POWER BAR MOUNTED TO SIDE PANEL (TYPICAL EACH PO5 LOCATION) DATA PHONE JACK, MOUNTED ON SIDE PANEL .101 UNIT E POS #4 4 -ELEVATION ELECTRICAL WIRES RUN THROUGH ACCESS HOLES PROVIDED IN UNITS E.G. SHALL PROVIDE CONDUIT AND IN -FLOOR JUNCTION BOX FOR TELEPHONE — E.G. SHALL PROVIDE CONDUIT 4 HUBBELL IN -FLOOR JUNCTION BOX (ISOLATED GROUND WIRE). 4 TERMINAL CASHWRAP WIRING DETAIL BULLETIN BOARD REMOTE TEST STATIONS FOR DUCT MOUNTED SMOKE DETECTORS ADJACENT TENANT M.I.G.) ELECTRICAL EQUIPMENT SEE SHEET E-3. MANAGER'S DESK A-18/20 (E) 208V-14), 304 WATER HEATER FOR LAVATORY SINK. A-10 51f14.4" GFI A-12 THERMOSTAT / CO2 SENSOR FOR RTU -1 A-8 REFRIDG. A-41/49 ZD -1 // // // // A-38/40/42 A-30 1 CARD TABLE A-6 E.G. SHALL PROVIDE CONNECTIONS TO GASH DESK RECEPTACLES AND POWER BARS (PROVIDED WITH CASH DESK) A5 SHOWN. ROUTE CONDUIT AND WIRE AS CALLED OUT VIA CASEWORK. COORDINATE ROUTING OF CONDUIT WITH MAURICE ,. SEE CASHWRAP WIRING DETAIL. 2#12,#12 GND,#12 ISOLATED GNP -1/2" C. A-28 POS #4 u 11111.1W11111111. ) vir Y AI P05 #2 ELECTRICAL ACCESS PANEL LOCATION 1. FIXTURE VENDOR PROVIDES TWO 4-PLEX RECEPTACLES AND ONE POW4R BAR FOR EACH TERMINAL (ONE GENERAL 4-PLEX, ONE ISOLATED GROUND (ORANGE) 4-PLEX LABELED "POS ONLY" W/ MIN. OF 10 FEET OF WIRE WITHOUT PLUGS ON THE END. 2. ELEC. CONTRACTOR SHALL PROVIDE (1) IN -FLOOR J -BOX (120 VOLT CIRCUIT) AND (1) IN -FLOOR J -BOX (DEDICATED POS CIRCUITS) AND HARDWIRE EASING WIRES FROM CASHWRAP TO APPROPRIATE J -BOXES. 3. ELEC. CONTRACTOR SHALL PROVIDE A LOCKOUT AT PANEL FOR EACH ISOLATED CIRCUIT FOR THE P05. 4. ISOLATED GROUND SHALL NOT CONNECT TO CONDUIT OR J -BOX. ADJACENT TENANT (N.I.C.) 1. FIXTURE VENDOR PROVIDES TWO 4 -FLEX RECEPTACLES AND ONE POYeR BAR FOR EACH TERMINAL (ONE GENERAL 4-PLEX, ONE ISOLATED GROUND (ORANGE) 4-PLEX LABELED "POE ONLY" W/ MIN. OF 10 FEET OF WIRE WITHOUT PLUGS ON THE END. 2. ELEC. CONTRACTOR SHALL PROVIDE (2) IN -FLOOR J -BOX (120 VOLT CIRCUIT) AND (2) IN -FLOOR J -BOX (DEDICATED POS CIRCUITS) AND HARDWIRE EXISTING WIRES FROM CASHWRAP TO APPROPRIATE I -BOXES. 3. ELEC. CONTRACTOR SHALL PROVIDE A LOCKOUT AT PANEL FOR EACH ISOLATED CIRCUIT FOR THE P05. 4. ISOLATED GROUND SHALL NOT CONNECT TO CONDUIT OR J -BOX. UNIT A UNIT B UNIT G UNIT D E.G. IS RESPONSIBLE FOR RUNNING WIRING AND FINAL ELECTRICAL HOOK-UP AFTER UNITS ARE SET IN PLACE AND LEVELED. E.G. IS RESPONSIBLE TO DRILL ANY ADDITIONAL HOLES INSIDE DESK TO ACCOMMODATE THE ELECTRICAL RUNS AS REQUIRED. POS #3 ORANGE FOURPLEX BOX. (ISOLATED GROUND WIRE) (TYPICAL EACH POE LOCATION) -ELEVATION 120 VOLT TO FOURPLEX OUTLET BOX E.G. SHALL PROVIDE CONDUIT AND HUBBELL IN -FLOOR JUNCTION BOX (WITH GROUND). E.G. 15 RESPONSIBLE FOR RUNNING WIRING AND FINAL ELECTRICAL HOOK-UP AFTER UNITS ARE SET IN PLACE AND LEVELED E.G. 15 RESPONSIBLE TO DRILL ANY ADDITIONAL HOLES INSIDE DESK TO ACCOMMODATE THE ELECTRICAL RUNS AS REQUIRED. VOICE PHONE JACK, MOUNTED ON SIDE PANEL POWER BAR MOUNTED TO SIDE PANEL (TYPICAL EACH PO5 LOCATION) DATA PHONE JACK, MOUNTED ON SIDE PANEL .101 UNIT E POS #4 4 -ELEVATION ELECTRICAL WIRES RUN THROUGH ACCESS HOLES PROVIDED IN UNITS E.G. SHALL PROVIDE CONDUIT AND IN -FLOOR JUNCTION BOX FOR TELEPHONE — E.G. SHALL PROVIDE CONDUIT 4 HUBBELL IN -FLOOR JUNCTION BOX (ISOLATED GROUND WIRE). 4 TERMINAL CASHWRAP WIRING DETAIL BULLETIN BOARD REMOTE TEST STATIONS FOR DUCT MOUNTED SMOKE DETECTORS ADJACENT TENANT M.I.G.) ELECTRICAL EQUIPMENT SEE SHEET E-3. MANAGER'S DESK A-18/20 (E) 208V-14), 304 WATER HEATER FOR LAVATORY SINK. A-10 51f14.4" GFI A-12 THERMOSTAT / CO2 SENSOR FOR RTU -1 A-8 REFRIDG. A-41/49 ZD -1 // // // // A-38/40/42 A-30 1 CARD TABLE A-6 E.G. SHALL PROVIDE CONNECTIONS TO GASH DESK RECEPTACLES AND POWER BARS (PROVIDED WITH CASH DESK) A5 SHOWN. ROUTE CONDUIT AND WIRE AS CALLED OUT VIA CASEWORK. COORDINATE ROUTING OF CONDUIT WITH MAURICE ,. SEE CASHWRAP WIRING DETAIL. 2#12,#12 GND,#12 ISOLATED GNP -1/2" C. A-28 I STUB 3/4" C. TO ABOVE CEILING FOR POE EQUIP. PANEL 24412,402 GND #12 ISOLATED OND -1/2" C. (2) ISOLATED GROUND 4-PLEX RECEPTACLES PROVIDED WITH CASH DESK (TYPICAL OF 2 LOCATIONS) POWER BAR PROVIDED WITH CASH DESK. (TYPICAL OF 4 LOCATIONS) STUB 3/4" C. TO ABOVE GEIUNG FOR SENSORMATIC DOOR -MAX. COORDINATE WITH SECURITY VENDOR. BATTERY POWERED ® SMOKE DETECTOR DEDICATED RECEPTACLE FOR SENSORMATIC DOOR -MAX SYSTEM. (ABOVE GEIUNG NEAR STOREFRONT) (TYP. OF 2) COORDINATE ADDITIONAL CONDUIT AND POWER REQUIREMENTS WITH SECURITY VENDOR. V� 1 STUB 3/4" C. TO ABOVE CEILING FOR SENSORMATIC DOOR -MAX. COORDINATE WITH SECURITY VENDOR. A-9 THRU " TC1 RTU -21® n COL COQ POWER PLAN SCALE: 1/4" =1'-0" ADJACENT TENANT COL COL 0 1' RECEPTACLE SHALL BE MOUNTED IN CEILING 6" FROM FACE AND 12" FROM CORNER OF WALL IN ACOUSTICAL CEILING. (TYPICAL OF 4 LOCATIONS) 3' EXISTING MALL CONCOURSE (N.I.C.) COL 64 0 RECEIVED CITY OF TUKWILA AUG 1 2 2013 ERMIT CENTER 5' 10' 2' 4' SCALE: %" =1'-0" O O M 0 W E 0 C) U 0 Cl) z LL; N W tt7 Z vl I— d; LL W W Lo W C'3w W v Woc W0z cg ZCn () d' L C7wv'� d' fAI Z = cKo �° W co co l- .1" ® W Ig. 41/4— co W Z co (1) 0 a. a) c n J JQ 0_i L..<4 I—w c° r DO Lu 0) = Q Z I WW D ouJ Eli co C/)N U) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: POWER PLAN SHEET E-2 OF 22 SHEETS -Iral., 11111.1W11111111. vir Y AI I STUB 3/4" C. TO ABOVE CEILING FOR POE EQUIP. PANEL 24412,402 GND #12 ISOLATED OND -1/2" C. (2) ISOLATED GROUND 4-PLEX RECEPTACLES PROVIDED WITH CASH DESK (TYPICAL OF 2 LOCATIONS) POWER BAR PROVIDED WITH CASH DESK. (TYPICAL OF 4 LOCATIONS) STUB 3/4" C. TO ABOVE GEIUNG FOR SENSORMATIC DOOR -MAX. COORDINATE WITH SECURITY VENDOR. BATTERY POWERED ® SMOKE DETECTOR DEDICATED RECEPTACLE FOR SENSORMATIC DOOR -MAX SYSTEM. (ABOVE GEIUNG NEAR STOREFRONT) (TYP. OF 2) COORDINATE ADDITIONAL CONDUIT AND POWER REQUIREMENTS WITH SECURITY VENDOR. V� 1 STUB 3/4" C. TO ABOVE CEILING FOR SENSORMATIC DOOR -MAX. COORDINATE WITH SECURITY VENDOR. A-9 THRU " TC1 RTU -21® n COL COQ POWER PLAN SCALE: 1/4" =1'-0" ADJACENT TENANT COL COL 0 1' RECEPTACLE SHALL BE MOUNTED IN CEILING 6" FROM FACE AND 12" FROM CORNER OF WALL IN ACOUSTICAL CEILING. (TYPICAL OF 4 LOCATIONS) 3' EXISTING MALL CONCOURSE (N.I.C.) COL 64 0 RECEIVED CITY OF TUKWILA AUG 1 2 2013 ERMIT CENTER 5' 10' 2' 4' SCALE: %" =1'-0" O O M 0 W E 0 C) U 0 Cl) z LL; N W tt7 Z vl I— d; LL W W Lo W C'3w W v Woc W0z cg ZCn () d' L C7wv'� d' fAI Z = cKo �° W co co l- .1" ® W Ig. 41/4— co W Z co (1) 0 a. a) c n J JQ 0_i L..<4 I—w c° r DO Lu 0) = Q Z I WW D ouJ Eli co C/)N U) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: POWER PLAN SHEET E-2 OF 22 SHEETS ELECTRICAL PANEL SCHEDULES Panel lAtiring Panelboard Type NEMA Type Schedule (3-phase) "A' Voltage Mains Mounting 120/205 Phase Mains Options 3 Y‘lire AIG Rating Note 4 9.584 GE AL OR EQUAL 300A MGB 400A 10,000 Enclsre 1 SURFACE 15.600 SHOW WINDOW LIGHTING ** ISOLA I t1.) GROUND BAR 5.600 28 ' x 200w/ FT 5.600 RECEPTACLES Gkt No Zone Load Description Equip it Brkr Opts Brkr Size Actual KIN Phase Actual KIN Brkr Size Brkr Opts Equip # Load Description Zone Gkt No 1 0.000 EXIT LIGHTS 0.000 L 20/1 0.200 A 0.480 20/1 34.005 34.005 MANAGER RECEPTACLES 34.005 2 3 TO STOREFRONT TRACK LT5 TOTAL 64.181 20/1 0.230 B 0.950 20/1 IG IN P.0.5. EQUIPMENT SYSTEM VOLTAGE x T3 84.477 x 1000 4 5 TC STOREFRONT CAN LIGHTS ---- 20/1 0.564 G 0.540 20/1 SALES RECEPTACLES 6 1 TC STOREFRONT SIGNS ---- 20/1 1.200 A 0.8E0 20/1 REFRIGERATOR 8 9 TG STOREFRONT RECEPTS ---- 20/1 0.120 5 1.260 20/1 ---- LAV/NS RECEPTACLES 10 11 TG STOREFRONT LIGHTBOX ---- 20/1 1.000 G 0.120 20/1 ---- SALES/FIT RM RECEPT 12 13 SPARE --- 20/1 0.000 A 0.550 20/1 SENSORMATIC REGEPTS 14 15 NONSALES LIGHTS -- 20/1 0.115 B 0300 20/1 TG/CONTACTORS 16 11 G SALES TRACK LIGHTS -- 20/1 0.165 G 1.500 20/2 (E) WATER HEATER 18 19 C SALES TRACK LIGHTS ---- 20/1 0.829 A 1.500 20 21 G SALES TRACK LIGHTS ---- 20/1 0.711 B 0.120 20/1 IG CASHWRAP REGEPT 22 23 G SALES TRACK LIGHTS ---- 20/1 0.514 G 0.720 20/1 IG CASITYVRAP REGEPT 24 25 G SALES PENDANTS ---- 20/1 1.652 A 0.120 20/1 GASHWRAP REGEPT 26 21 G FITTING RM PENDANTS ---- 20/1 1.258 5 0.120 20/1 GASHINR4P RECEPT 25 29 G SALES TRACK LIGHTS --- 20/1 0.168 G 0360 20/1 HVAC RECEPTACLES 30 31 SPARE ---- 20/1 0.000 A 5.949 60/3 H RTU -1 32 33 A SALES FLUORESCENTS --- 20/1 1.561 B 5.949 34 35 5 SALES FLUORESCENTS ---- 20/1 1.313 G 5.949 36 31 A SALES FLUORESCENTS ---- 20/1 0.145 A 5.356 50/3 H EX. RTU -2 35 39 B SALES FLUORESCENTS ---- 20/1 0.146 B 5.356 40 41 SALES NIGHT LIGHTS L 20/1 0.186 G 5.356 42 43 SPARE ---- 20/1 0.000 A 0.000 20/1 SPARE 44 45 SPARE ---- 20/1 0.000 5 0.000 20/1 SPARE 46 41 UH -1 --' 20/2 1.500 G 0.000 20/1 SPARE 45 49 1500 A 0.000 20/1 SPARE 50 51 SPARE ---- 20/1 0.000 5 0.000 20/1 SPARE 52 53 SPARE ---- 20/1 0.000 G 0.000 20/1 SPARE 54 Notes breakers to be 20 Amp, 1 Load Tot Ph. A Ph. 13 Ph. C Total (All Phases to be balanced -Pole unless 21.594 otherwise kw kw kw kw 7% using 180 noted. A A A A Load Totals.) Brkr Opts: L - Handle lock -on device H - Heating, A/C 4 Refrigeration G - Ground Fault Circuit Interrupter IG - Isolated Ground Lighting Control Zones * All circuit Actual Zone: 21.339 118 21.248 111 64.181 1782 to within Actual ELECTRICAL LOAD SUMMARY 1SYSTEM2o/208V DESCRIPTION ACTUAL CONNECTED KW/KVA N.E.C. CONNECTED KW/KVA N.E.C. DEMAND FACTOR N.E.C. DEMAND KW/KVA LIGHTING 9.584 9.584 1.25 11.980 TRACK LIGHTING *** 3.070 15.600 208 ' x 150W / 2FT 15.600 SHOW WINDOW LIGHTING ** 0.230 5.600 28 ' x 200w/ FT 5.600 RECEPTACLES 8.612 8.612 1.0<10KW+0.5 REMAINING KW 8.612 ELECTRIC WATER HEATER 3.000 3.000 1.0 3.000 MISCELLANEOUS 2.680 2.680 1.0 2.680 MOTORS 0.000 0.000 1.0 0.000 FIXED ELECTRIC HEATING 3.000 3.000 1.0 3.000 HVAC SYSTEM 34.005 34.005 125% OF LARGEST 34.005 TOTAL 64.181 82.081 FT OR ACTUAL CONNECTED) FT OR ACTUAL CONNECTED) ALREADY INCLUDED AMPERAGE AMPS 84.477 NOTES LOAD OF THE 220-43 REQUIREMENT 220-43 REQUIREMENT LARGEST MOTOR CONNECTED 1000 TWO CATAGORIES (200VA / (150VA/2 OR COMPRESSOR KW/KVA TOTAL = MINIMUM FEEDER 234.8 IN * USE GREATER ** NEC ARTICLE *** NEC ARTICLE **** 125% OF T1 -IE ACTUAL & NEC N.E.C. DEMAND KVAx SYSTEM VOLTAGE x T3 84.477 x 1000 208 x 1.73 ELECTRICAL SPECIFICATIONS DIVISION SIXTEEN/ELECTRICAL 16001- DESIGN INFORMATION A. NOTE: CARE SHOULD BE TAKEN TO AVOID MODIFICATION TO IN-PLACE SPRINKLER HEADS WHERE POSSIBLE. B. DEFINITION: "PROVIDE" MEANS TO "FURNISH AND INSTALL"; NEC 15 NATIONAL. ELECTRICAL CODE. C. EXISTING UTILITIES SYSTEMS, LINES OR OTHER ELECTRICAL WIRING, AND EQUIPMENT ARE NOT SHOWN. EXAMINE SITE CAREFULLY PRIOR TO BIDDING. D. COMPLY WITH ALL REQUIREMENTS OF GENERAL CONDITIONS, SUPPLEMENTARY GENERAL CONDITIONS, AND ALL CONTRACT DOCUMENTS WHICH PERTAIN TO THIS PROJECT. E. RELATED ELECTRICAL WORK TO BE DONE BY OTHERS UNDER SEPARATE CONTRACT OR TO BE DONE UNDER ANOTHER DIVISION A5 15 INDICATED ON THE DRAWINGS OR SPECIFICATIONS HEREIN. F. PAY FOR ALL PERMITS, FEES, INSPECTION SERVICES, TAXES, AND ROYALTIES. G ELECTRICAL DRAWINGS ARE DIAGRAMMATIC AND INDICATE GENERAL DESIGN, LAYOUT, AND ARRANGEMENT OF EQUIPMENT OF SYSTEMS. DO NOT SCALE DRAWINGS FOR DIMENSIONS. TAKE DIMENSIONS FROM ARCHITECTURAL DRAWINGS AND ACTUAL EQUIPMENT; VERIFY IN FIELD. H. ELECTRICAL CONTRACTOR SHALL HAVE READ AND BE FAMILIAR WITH THE GENERAL AND MECHANICAL SPECIFICATIONS AND PLANS. I. ENTIRE INSTALLATION SHALL CONFORM TO LATEST REQUIREMENTS OF LOCAL, STATE, AND NATIONAL ELECTRICAL CODE AND OF THE LOCAL ELECTRICAL INSPECTION AUTHORITY WHO SHALL HAVE FINAL JURISDICTION. PROVIDE SUPERIOR INSTALLATION. J. FURNISH PROJECT DATA, SUBMITTAL AND SHOP DRAWINGS WHERE REQUIRED FOR REVIEW BY ARCHITECT PRIOR TO INSTALLATION. K NOTIFY MAURICES IN WRITING OF ANY DEVIATIONS FROM THE PLANS. GENERAL CONTRACTOR SHALL PROVIDE "AS -GUILTS" DRAWINGS OF ALL ELECTRICAL SYSTEMS UPON COMPLETION OF WORK TO MAURICES INCORPORATED. MAJOR DEVIATIONS MUST BE APPROVED BY THE ELECTRICAL ENGINEER IN WRITING BEFORE IMPLEMENTATION. L. GOOD WORKMANSHIP AND APPEARANCE ARE CONSIDERED OF EQUAL IMPORTANCE WITH ELECTRICAL AND MECHANICAL OPERATION. M. PROVIDE TEMPORARY ELECTRICAL SERVICE AND DISTRIBUTION A5 REQUIRED FOR CONSTRUCTION POWER AND LIGHTING. REMOVE TEMPORARY WIRING UPON COMPLETION OF PROJECT. SCHEDULE ELECTRICAL POWER OUTAGES AT CONVENIENCE OF OWNER. N. PROVIDE ALL CORE DRILLING, CHANNELING, CUTTING AND PATCHING NECESSARY FOR ELECTRICAL WORK ARRANGE WITH GENERAL CONTRACTOR FOR NECESSARY OPENINGS AND CHASE. SEAL HOLES CUT FOR WIRING RUNS. REFINISH BUILDING STRUCTURE WHERE DAMAGED DUE TO ELECTRICAL WORK SEE ARCHITECTURAL SPECIFICATIONS, DIVISION TWO, FOR EXACT REQUIREMENTS. 0. REMOVE, CAP OR ABANDON ALL ELECTRICAL WORK IN AREAS TO BE REMODELED EXCEPT WHERE FOUND TO BE REUSABLE IN NEW WORK. RECONNECT EXISTING OUTLETS WHICH WILL REMAIN. REMOVE CONDUITS AND CONDUCTORS WHICH SHALL NOT BE UTILIZED IN THE NEW WORK. DISPOSE OF SALVAGE AS DIRECTED BY ARCHITECT. P. PROVIDE ALL MATERIALS WHICH ARE NEW, FIRST QUALITY, LISTED BY UNDERWRITERS' LABORATORIES, INC., AND APPROVED BY MAURICES. REUSE EXISTING WHERE INDICATED ON PLANS. REPLACE AND PAY FOR MATERIALS AND EQUIPMENT DAMAGED OR LOST DURING THE COURSE OF INSTALLATION. SUBSTITUTE MATERIALS AND EQUIPMENT MUST BE APPROVED BY MAURICES PRIOR TO INSTALLATION. Q. MAKE OWN PROVISIONS FOR DELIVERY AND SAFE STORAGE OF MATERIALS AND EQUIPMENT. STORE MATERIALS AND EQUIPMENT OUT OF THE WEATHER AND PROTECT FROM DAMAGE, THEFT AND VANDALISM. R. CLEAN ALL ELECTRICAL EQUIPMENT OF CONSTRUCTION DIRT PRIOR TO COMPLETION OF WORK. TOUCH UP OR REPAINT SCARS, BLEMISHES, RUST SPOTS, ETC., ON ELECTRICAL EQUIPMENT. FINISH PAINTING, WHERE DONE IN FIELD, WILL BE DONE BY OTHER TRADES. SEE ARCHITECTURAL SPECIFICATION, DIVISION 9. S. TEST ENTIRE ELECTRICAL INSTALLATION PRIOR TO COMPLETION OF WORK. ALL SYSTEMS MUST BE IN GOOD OPERATING ORDER. T. PROVIDE AND INSTALL BATTERY POWERED, SINGLE STATION, SMOKE ALARMS WITH INTEGRAL HORN, LED, AND INDICATOR LIGHT AS LOCATED ON THE DRAWINGS. U. PROVIDE ELECTRICAL HOOK-UP TO THE MOTORIZED OVERHEAD GRILLE MOTOR(S) WHERE APPLICABLE. V. ALL ELECTRICAL AND TELEPHONE OUTLETS AND CONDUIT TO SAME MAY BE SURFACE MOUNTED IN THE NON -SALES AREAS ONLY. NOTCH SHELVING A5 REQUIRED TO CLEAR CONDUIT. W. REFER TO ARCHITECTURAL SPECIFICATIONS AND DRAWINGS FOR 'TASK RESPONSIBILITIES". 16400 SERVICE AND DISTRIBUTION A. PROVIDE ELECTRICAL SERVICE ENTRANCES, INCLUDING METERING, MAIN SWITCHES, SERVICE FEEDERS, PANELBOARDS, DRY TYPE TRANSFORMERS (AS REQUIRED) ETC., FOR MAURICES SPACES A5 INDICATED. VERIFY SERVICE VOLTAGE TO BE UTILIZED AND POINT ORIGINATION OF SERVICE ENTRANCE TO MAURICES SPACE. B. EACH MAURICES SPACE WILL BE SEPARATELY METERED. INSTALL TERMINAL BLOCKS, METERS, AND CURRENT AND POTENTIAL TRANSFORMERS FURNISHED BY LOCAL UTILITY COMPANY. PROVIDE CT AND PT CABINETS WHERE REQUIRED. C. GROUND ALL ELECTRICAL SYSTEMS IN ACCORDANCE WITH REQUIREMENTS OF NATIONAL, STATE, AND LOCAL ELECTRICAL CODES. MAKE ALL JOINTS AND CONNECTIONS OF CONDUIT SYSTEM TIGHT TO MAINTAIN CONTINUITY OF MECHANICAL GROUND. EFFECTIVELY GROUND ALL ELECTRICAL AND MECHANICAL EQUIPMENT. PROVIDE A SEPARATE GROUNDING CONDUCTOR FOR ALL FLEXIBLE METAL CONDUITS, PVC CONDUITS, AND SURFACE WIRING GUTTERS. GROUND PANELBOARD CABINETS TO GROUNDING CONDUCTOR. DO NOT USE NEUTRAL CONDUCTOR AS A GROUNDING CONDUCTOR. PROVIDE SEPARATE "INSULATED/ISOLATED" GROUNDING CONDUCTORS FOR ELECTRONIC CIRCUITS. D. PROVIDE ENGRAVED BAKELITE NAMEPLATES FOR ALL ELECTRICAL DISTRIBUTION EQUIPMENT. PROVIDE TYPED DIRECTORY CARDS FOR ALL PANEL BOARDS. PERMANENTLY IDENTIFY SERVICE AND FEEDER CABLES IN JUNCTION AND PULL BOXES. E. PROVIDE CONDUITS AS FOLLOWS: 1. RIGID GALVANIZED STEEL (RGS) - WHERE EXPOSED TO WEATHER. 2. ELECTRICAL METALLIC TUBING (EMT), ALUMINUM CONDUIT (A/C), OR INTERMEDIATE METAL CONDUIT (IMC) - IN PARTITIONS AND ABOVE ACOUSTICAL MODULAR PANEL SYSTEM AND INHERE EXPOSED IN DRY AREAS. DO NOT INSTALL IN OR UNDER FLOOR SLAB WHICH 15 IN CONTACT WITH THE GROUND. 3. FLEXIBLE METAL CONDUIT (FMC) - FINAL CONNECTIONS TO MOTORS AND RECESSED LIGHTING FIXTURES. LIQUID -TIGHT INHERE EXPOSED TO THE WEATHER OR MOISTURE. 4. PVC CONDUITS - WHERE INSTALLED IN OR UNDER GROUND FLOOR SLAB. F. PROVIDE CONDUITS AS FOLLOWS: 1. RGS, EMT, IMC - GENERAL ELECTRIC, REPUBLIC STEEL, OR EQUAL. 2. ALUMINUM CONDUIT - HEAVY WALL, ANACONDA, HARVEY, KAISER, OR EQUAL. 3. PVC CONDUIT - HEAVY WALL, SCHEDULE 40 AND 90 DEGREES C (EPC), RIGID UL LISTED, BALDWIN, CARLON, TRIANGLE, OR EQUAL. G. PROVIDE APPROVED COUPLINGS AND CONNECTORS FOR ALL CONDUIT RACEWAYS. MAKE ALL JOINTS TIGHT. EMT CONNECTORS SHALL BE STEEL SET SCREW TYPE. H. PROVIDE ALL INSERTS, SUPPORTS, FRAMEWORK, HANGERS, CLAMPS, AND OTHER FACILITIES REQUIRED TO PROPERLY INSTALL ELECTRICAL EQUIPMENT. SUPPORT CONDUIT RUNS AT INTERVALS AS REQUIRED BY NEC. I. PROVIDE SURFACE METAL WIRING GUTTERS, MINIMUM SIZE 4"X 4" WHERE REQUIRED FOR SPLICES, TAPS, WIRING, ETC. PROVIDE NEMA SR WHERE SUBJECT TO WEATHER CONDITIONS. SQUARE D, SIEMENS, HOFFMAN, OR EQUAL. J. PROVIDE CODE GAUGE STEEL PULL BOXES AND JUNCTION BOXES WHERE REQUIRED BY NEC. DO NOT INSTALL IN INACCESSIBLE LOCATIONS. K. COORDINATE LOCATION OF LIGHTING FIXTURES, OUTLETS AND ALL ELECTRICAL EQUIPMENT WITH OTHER TRADES TO AVOID INTERFERENCES AND OBSTRUCTIONS AND 50 THAT EQUIPMENT INSTALLED BY OTHERS WILL NOT BLOCK ELECTRICAL EQUIPMENT OR MAKE IT INACCESSIBLE OR INOPERABLE. PROVIDE WEATHER-PROOF OUTLETS WHERE INSTALLED OUTDOORS. L. PROVIDE GALVANIZED PRESSED STEEL OUTLET BOXES, MINIMUM 1 1/2" DEEP, AND OF PROPER SIZE AND DESIGN FOR LIGHTING FIXTURES OR DEVICES AND NUMBER OF CONDUCTORS CONTAINED. SIZE OF OUTLET BOX DETERMINED ON BASIS OF SINGLE GANG MODULE FOR EACH DEVICE INSTALLED. M. LIGHTING OUTLETS - MINIMUM 4" BOX TO ACCOMMODATE TYPE OF FIXTURE BEING INSTALLED. N. SWITCH OUTLETS - 4'- 6" ABOVE THE FLOOR AN THE LATCH SIDE OF DOOR. 0. RECEPTACLE OUTLETS -12" ABOVE FLOOR IN GENERAL. SEE ARCHITECTURAL FLOOR PLAN FOR ANY DIFFERING MOUNTING HEIGHTS. P. TELEPHONE OUTLETS -12" ABOVE FLOOR FOR PARTITION PHONES. SEE ARCHITECTURAL PLAN FOR DIFFERING MOUNTING HEIGHTS. Q. FLOOR TELEPHONE OUTLETS - FLUSH IN FLOOR; PROVIDE CARPET FLANGES IN CARPETED AREAS. HUBBELL #52529 BOX WITH #52525 COVER OR EQUAL BY STEEL CITY. R. FLOOR RECEPTACLE OUTLET - FLUSH IN FLOOR; PROVIDE CARPET FLANGES IN CARPETED AREAS. HUBBELL #62529 BOX WITH #53125 COVER OR EQUAL BY STEEL CITY. 5. PROVIDE COPPER CONDUCTORS, SOO VOLTS, MINIMUM SIZE *12, UL LISTED STANDARD BUILDING WIRE. T. PROVIDE THHN FOR CONDUCTORS 44 AND LARGER. U. PROVIDE THHN FOR WIRING TO H.I.D., FLUORESCENT, OR SLIMLINE FIXTURES; FOR ALL WIRING IN OR ON ROOF DECK OR ROOF INSULATION OR WHERE EXPOSED TO THE SUN; AND FOR ALL REMODEL WORK V. PROVIDE SOLID CONDUCTORS #10 AWG AND SMALLER; STRANDED CONDUCTORS #8 AWG AND LARGER. W. PROVIDE SPLICES IN READILY ACCESSIBLE OUTLETS OR WIRING GUTTER. PROVIDE APPROVED INSULATED PRESSURE CONNECTORS FOR ALL SPLICES. X. PROVIDE THE FOLLOWING DEVICES AND PLATES: 1. SWITCHES - HUBBELL 20 AMP, 1220 SERIES. SWITCHES TO BE A -C, TUMBLER, QUIET TYPE. 2. RECEPTACLES - HUBBELL 5362-1 OR 5362-WHI. 3. TWIST LOCK RECEPTACLES WITH ISOLATED GROUND - 3 WIRE, ISOLATED GROUND, ORANGE, 20 AMP DUPLEX, HUBBELL #IG2310. PROVIDE MATCHING PLUG. 4. RECEPTACLE WITH GROUND FAULT CIRCUIT INTERRUPTER - HUBBELL GF5362-I. 5. DEVICE PLATES - ONE PIECE TYPE AND SHAPE SUITABLE FOR THE DEVICES AND OUTLETS INSTALLED DEVICE PLATES SHALL BE SUITABLE TO ACCEPT PAINT. S. COLOR - ALL ELECTRICAL SWITCHES, RECEPTACLES AND PLATES IN THE SALES AREA SHALL BE WHITE. ALL ELECTRICAL SWITCHES, RECEPTACLES AND PLATES IN NON -SALES AREA SHALL BE WHITE. 1. PROVIDE EDWARD 120 VOLT AC #852 WEATHERPROOF PUSHBUTTON, #340A -N5 BUZZER, OR EQUAL. 8. ACCEPTED SUBSTITUTES - EQUIVALENT SPECIFICATION GRADE DEVICES BY BRYANT, G.E., ARROW HART, P +I 5, SIERRA LEVITON, SLATER. Y. PROVIDE ENER-COMM ECD -3000 DIGITAL CHECK METER IF NO UTILITY METER EXISTS. METERS CAN BE PURCHASED FROM: GLOBAL POWER PRODUCTS 225 ARNOLD ROAD LAWRENCE, GEORGIA 30044 CONTACT: KATHY PHONE: (800) 886-3831 EXT. 105 FAX: (110) 136-8231 Z. CONTRACTORS MUST SPECIFY METER 15 TO BE INSTALLED IN A MAURICES STORE WHEN ORDERING. METER COMES WITH ALL HARDWARE TO ASSEMBLE METER. M. GENERAL CONTRACTOR MUST CONTACT MAURICES CONSTRUCTION REPRESENTATIVE FOR METER TYPE. AB. PROVIDE ENCLOSED, FUSIBLE OR NONFUSIBLE SAFETY SWITCHES WHERE INDICATED OR HEREIN SPECIFIED. SAFETY SWITCHES SHALL BEAR THE UL LABEL, SUITABLE FOR THE SURROUNDING AREA AND CONDITIONS. SWITCHES SHALL BE MINIMUM NORMAL DUTY, HORSEPOWER RATED AND SHALL HAVE QUICK -MAKE AND QUICK -BREAK MECHANISMS. SWITCHES USED ON MOTOR CIRCUITS SHALL HAVE ADEQUATE HORSEPOWER RATINGS FOR THE MOTORS SERVED. AC. SAFETY SWITCHES EMPLOYED AS MOTOR DISCONNECT DEVICES FOR TWO (2) OR MORE LOADS SHALL BE FUSIBLE TYPE FOR REJECTION -TYPE FUSES. AD. HEAVY DUTY INDUSTRIAL TYPE SAFETY SWITCHES SHALL BE USED FOR 600 VOLT APPLICATION AND SHALL BE HORSEPOWER RATED WITH QUICK -MAKE, QUICK -BREAK MECHANISMS AND INTERLOCKED COVERS. SWITCHES SHALL BE AS MANUFACTURED BY CUTLER -HAMMER, GENERAL ELECTRIC, SEIMENS, SQUARE D, OR A5 ACCEPTED, AND ALL SWITCHES PROVIDED SHALL BE BY THE SAME MANUFACTURER. AE. PROVIDE DUAL ELEMENT "FUSETRONS" BY BUSSMANN UNLESS FASTER CURRENT LIMITING FUSES ARE REQUIRED FOR PROTECTION OF SYSTEM FROM AVAILABLE FAULT CURRENT. USE BUSSMANN "LIMITRON" REJECTION TYPE FU5E5 IN MAIN SERVICE EQUIPMENT. AF. PROVIDE NEW CIRCUIT BREAKER BRANCH PANELBOARDS WITH MAIN LUGS ONLY, OR MAIN BREAKERS WHERE INDICATED, RATED FOR VOLTAGE SUPPLY WHERE INSTALLED, WITH AMPACITY OF BUS, AND WITH NUMBER AND SIZE OF FULL WIDTH, THERMAL MAGNETIC, BOLTED BRANCH CIRCUIT BREAKERS INDICATED. PROVIDE BREAKERS RATED FOR SWITCHING AND RATED MINIMUM 22,000 AMPS SYMMETRICAL SHORT CIRCUIT CURRENT AT RATED VOLTAGE OF PANELBOARD. PROVIDE 2 AND 5 POLE BREAKERS WITH COMMON TRIP AND SINGLE OPERATING HANDLE. PROVIDE SEPARATE GROUND BUS IN PANEL BOARD FOR "INSULATED/ISOLATED" CIRCUITS TO CASH REGISTER; CONNECT TO INSULATED GROUNDING CONDUCTOR AT SERVICE ENTRANCE. PROVIDE EQUIPMENT GROUND BUS "WAFER-THIN" OR "TWIN" CIRCUIT BREAKERS NOT ACCEPTABLE FOR NEW PANELBOARDS. PROVIDE LOCK ON DEVICES FOR CIRCUITS AS SELECTED BY MAURICES. MOUNT PANELBOARDS 6'- 6" ABOVE FLOOR TO TOP OF CABINET. PANELBOARDS - SQUARE D TYPE NO FOR 120/208 VOLT SYSTEMS, AND TYPE NF FOR 341/600 VOLT SYSTEMS, OR EQUIVALENT BY GENERAL ELECTRIC, SEIMENS, OR CUTLER -HAMMER. AG. PROVIDE 100 PERCENT NEUTRAL BUS AND 25 PERCENT GROUND BUS. GROUND ALL ENTERING CONDUITS TO GROUND BUS. PROVIDE INSTRUMENT TRANSFORMER COMPARTMENT FOR LOCAL POWER COMPANY METERING UNLESS SEPARATE ENCLOSURE IS REQUIRED BY LOCAL POWER COMPANY. AH. PROVIDE CIRCUITS, OUTLETS, FEEDERS, DISCONNECT SWITCHES, AND THERMAL OVERLOAD SWITCHES AND MAKE ALL POWER CONNECTIONS TO MECHANICAL EQUIPMENT SUCH A5 PLUMBING, HEATING, VENTILATING AND AIR CONDITIONING EQUIPMENT. PROVIDE FUSED SWITCHES OR CIRCUIT BREAKERS IN PANELBOARD FOR FEEDERS TO EQUIPMENT. PROVIDE FUSED DISCONNECTS SWITCHES AT PACKAGE HVAC OR AC EQUIPMENT; PROVIDE SIZE AND TYPE OF FUSES AS REQUIRED BY MANUFACTURER OF MECHANICAL UNIT. PROVIDE DISCONNECT SWITCHES OR MOTOR RATED TOGGLE SWITCHES WHERE OUT OF SIGHT OF CONTROLLER PER NEC. INSTALL AND CONNECT MAGNETIC STARTERS FURNISHED BY OTHERS FOR ELECTRIC UNIT HEATER. PROVIDE WEATHERPROOF RECEPTACLE OUTLET WITHIN 25 FEET OF MECHANICAL EQUIPMENT LOCATED ON ROOF OR WHERE EXTERIOR. Al. TEMPERATURE CONTROL WIRING, INCLUDING INTERLOCKS WITH OTHER MECHANICAL EQUIPMENT, SHALL BE DONE UNDER THE MECHANICAL DIVISION, UNLESS THESE CONTROLS CARRY THE FULL LOAD CURRENT TO THE MECHANICAL EQUIPMENT, IN WHICH CASE, THIS WIRING SHALL BE PROVIDED UNDER THIS ELECTRICAL CONTRACT. AJ. PROVIDE CIRCUITS, FEEDERS, OUTLETS, AND SWITCHES AND MAKE ALL CONNECTIONS TO EXHAUST FANS. PROVIDE WIRING TO LIGHT SWITCH UNLESS INTERLOCKED WITH OTHER MECHANICAL EQUIPMENT. AK. PROVIDE TORK EW120B SERIES, 1- DAY TIME CLOCK IN NON -SALES AREA TO CONTROL STOREFRONT SIGNAGE. MALL ON AT 9:00 A.M., OFF AT 10:00 P.M. STRIP CENTERS AND DOWNTOWN LOCATIONS ON AT 9:00 A.M., OFF AT 11:00 P.M. 16500 - LIGHTING A. FOR PURPOSES OF THIS PROJECT, GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FABRICATION AND INSTALLATION OF SIGN, INCLUDING ATTACHMENT OF LETTERS AND PULLING OF CONDUIT AND WIRE TO EACH LETTER FROM THE BALLAST (TRANSFORMER) POINT. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE FINAL CONNECTION TO PRIMARY SIDE OF TRANSFORMER. B. SIGNS SHALL BE SERVED WITH 120 VOLT ELECTRICAL SERVICE. C. PROVIDE COMPLETE SYSTEMS FOR INTERIOR LIGHTING A5 INDICATED. INSTALL AND CONNECT LIGHTING FIXTURES FURNISHED BY MAURICE ,. COMPLETELY CONNECT AND SECURELY MOUNT ALL FIXTURES; PROVIDE ALL ADDITIONAL SUPPORTS AND HANGERS AS MAY BE NECESSARY TO SECURELY FASTEN AND SUPPORT FIXTURES TO CEILING. GENERAL CONTRACTOR SHALL USE UNISTRUT OR SIMILIAR PRODUCT TO SUPPORT LIGHT FIXTURES IN OPEN CEILING AREAS. D. MAURICES SHALL FURNISH ALL LIGHT FIXTURES, LIGHT TRACK, LAMPS, EXIT, EMERGENCY AND ILLUMINATED SIGNS, EXCEPT FOR NEON TUBING. GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR FINAL CONNECTION TO ALL MAURICES SUPPLIED FIXTURES. E. CIRCUIT NIGHT LIGHT(S) FOR INDEPENDENT OPERATION DURING NIGHT HOURS AND CONTINUOUS OPERATION DURING,OPEN HOURS. 16100 - COMMUNICATIONS A. PROVIDE COMPLETE TELEPHONE RACEWAYS SYSTEM, INCLUDING OUTLETS AND CONDUIT RUNS, FOR EACH MAURICES SPACE AS INDICATED AND IN CONFORMANCE WITH REQUIREMENTS AND RECOMMENDATIONS OF LOCAL TELEPHONE COMPANY. VERIFY CONDUIT SIZES. B. C. D. PROVIDE PARTITION SPACE AND PLYWOOD BACKBOARD FOR TERMINAL EQUIPMENT. PROVIDE CONDUIT TO WATER PIPE FOR GROUND. PROVIDE SERVICE ENTRANCE CONDUIT TO TERMINATION POINT AS INDICATED. VERIFY SIZE OF TELEPHONE BOARD WITH LOCAL TELEPHONE COMPANY. ELECTRICAL LEGEND MDG CA 0 C WP AC eE ELECTRICAL PANEL MAIN DISTRIBUTION CENTER TELEPHONE TERMINAL BOARD CIRCUIT RUN; UNDERGROUND, FLOOR CIRCUIT RUN; IN WALLS AND CEILING CIRCUIT RUN; EXPOSED HOME RUN CEILING LUMINAIRE; LETTER INDICATES TYPE WALL LUMINAIRE; LETTER INDICATES TYPE INCANDESCENT LUMINAIRE; RECESSED FLUORESCENT LUMINAIRE; SURFACE FLUORESCENT LUMINAIRE; RECESSED FLUORESCENT STRIP LIGHT PORCELAIN KEYLESS LAMPHOLDER; BRYANT 5228 WITH 100 A-19 LAMP EXIT LIGHT DUPLEX RECEPTACLE; +12" AFF DUPLEX RECEPTACLE; WEATHERPROOF DUPLEX RECEPTACLE; ABOVE COUNTER DUPLEX RECEPTACLE; HALF SWITCHED DUPLEX RECEPTACLE; DOUBLE SWITCHED GFI 0 g St 02 TO R K LV ITP 11,4 DOUBLE DUPLEX RECEPTACLE; WALL DUPLEX RECEPTACLE WITH GROUND FAULT INTERRUPTER (GFI) FLOOR RECEPTACLE; FLUSH JUNCTION BOX; CEILING JUNCTION BOX; WALL CLOCK OUTLET TELEPHONE OUTLET +12" AFF FLOOR TELEPHONE OUTLET; FLUSH CRT OUTLET DIMMER SWITCH; AS NOTED SINGLE POLE SWITCH; SUBSCRIPT INDICATES SWITCHING DOUBLE POLE SWITCH THREE WAY SWITCH THERMAL OVERLOAD SWITCH SWITCH WITH PILOT LIGHT KEY OPERATED SWITCH LOW VOLTAGE SWITCH COMBINATION SWITCH AND RECEPTACLE TIME SWITCH; AS NOTED PUSHBUTTON STATION SURFACE RACEWAY; TYPE AS NOTED ©11 ELECTRICAL METER I FUSED DISCONNECT SWITCH MAGNETIC STARTER OR CONTACTOR COMBINATION STARTER/DISCONNECT SWITCH; AS NOTED FUSED DISCONNECT SWITCH; DIAGRAMMATIC 0 0 CIRCUIT BREAKER; DIAGRAMMATIC ELECTRICAL SERVICE ENTRANCE; OVERHEAD X TELEPHONE SERVICE ENTRANCE; OVERHEAD O CONDUIT UP CONDUIT DOWN SPECIAL PURPOSE RECEPTACLE; AS NOTED ITEMS SHADED INDICATES ON EMERGENCY CIRCUIT - LV - LOW VOLTAGE CONTROL WIRING V TV OUTLET AS NOTED ELECTRICAL ONE -LINE DIAGRAM LEASE LINE E.G. TO FURNISH AND INSTALL FOUR (4) 4350MCM + ONE (1) *4 GRD. + ONE (1) 44 I.G. IN 3" CONDUIT. COORDINATE WITH LANDLORD. EXISTING TO REMAIN 400 AMP DISCONNECT. E.G. TO INSTALL 500 AMP FUSES. FIELD VERIFY PRIOR TO BID. 7- EXISTING TO REMAIN SOCKET AND METER. FIELD VERIFY PRIOR TO BID. LANDLORD'S EXISTING 120/208V, 3194, 4h, ELECTRICAL WIREWAY. FLOOR PANEL 'A' 120/208V 54 SPACE, 3PH, 4W 500 AMP M.G.B. APPROXIMATE DISTANCE TO LANDLORD ELECTRICAL ROOM 15 SO LINEAR FEET. E.G. TO FURNISH AND INSTALL PANEL IN LOCATION SHOWN ON SHEET E-2. TC1' TC2' E.G. TO SUPPLY AND INSTALL CONTACTORS/TIMEGLOCKS, TO BE LOCATED AS SPACE ALLOWS IN VICINITY OF PANEL 'A'. A-16 'A' 'B'1)13,40 'C' SEPARATE PERMITAND APPROVAL REQUIRED RECEIVED CITY OF TUKWILA AUG I Z 2013 PERMIT CENTER CO CO U F- W CN W c v.) c 00 Q o_ Z Z_dM' 2 co I- w N W (-I;- D co J OWN 0 00 O cY') 0 J Zj LO Z l- . W 5 Z }. u W W000� WOZ •1- u) 5 Gi Z = co Wv)coI: co E N s U) a0 .0 00 O a (i)C Q J 00 � Z � u.IVQ Z �,.. w FT- UO -I O co r O 00 W co N CO JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC / MD -SS / CJ APPROVED BY : XX REVISIONS: SPECIFICATIONS SHEET E-3 OF 22 SHEETS PUSHBUTTON, REFER TO "BUZZER SYSTEM ONE -LINE" DETAIL ON THIS SHEET FOR WIRING INSTRUCTIONS. HEAVY DUTY ADAPTERBUZZER EDWARDS #340-N5 120V, .05 AMPS, 6VA MOUNTS ON FLUSH MOUNTED 4" BOX IN CEILING WEATHERPROOF PUSH BUTTON EDWARDS #852 FLUSH TYPE MOUNTED IN SINGLE GANG FLUSH BOX RATED AT 125V, 5.0 AMPS +12" AFF 2#12 - 1/2"C. TO NEAREST RECEPTACLE CIRCUIT AND MAKE CONNECTION. BUZZER SYSTEM ONE—LINE WX18' GLEA&.ARE 1" STUB (3) 3/4' CONDUIT TO ABOVE CEILING FOR EQUIPMENT PANEL AT CASHWRAF (WITH PULL WIRE) SUPPLIED AND INSTALLED BY ELECT CONTRACTOR 4 FLEX DEDICATED RECEPTACLE BY ELECT CONTRACTOR %2"x3'x3'PLYWOODMOUNTED TO WALL. SUPPLIED, INSTAI I FP AND FINISHED " A " BY G.G. METAL SHELF d 23%2" W x 20" D x 15" H BLACK ENCLOSURE SUPPLIED 4 INSTALLED BY FUJITSU. INSTALL WALL BRACKET TO PLYWD W/ (4) #10 1" WOOD SCREWS, HANG ENCLOSE 4 SECURE W/ METAL SET SCREWS PROVIDED. LEAVE ALL EXTRA PIECES, OWNER MANUAL, KEYS, ETC INSIDE ENCLOSURE PHONE BLOCK, INSTALLED BY CONTRACTOR STUB (1) 3/4' CONDUIT TO ABOVE CEILING FOR MANAGERS DESK (WITH PULL WIRE) SUPPLIED AND INSTALLED BY ELECT CONTRACTOR MANAGERS DESK 1.) CAT 5 WIRE FROM POS EQUIPMENT PANEL TO CASHWRAP SHALL BE PROVIDED AND INSTAI I F17 BY FUJITSU. MAURICES PROJECT MANAGER SHALL COORDINATE INSTALLATION WITH FUJITSU. INSTALLATION TO TAKE PLACE 1 WEEK PRIOR TO STORE PUNCH DATE. G.G. SHALL HAVE CASHWRAP INSTALLED 2.) CAT 5 WIRE FROM POS EQUIPMENT PANEL TO MANAGERS DESK SHALL BE PROVIDED AND INSTALLED BY FUJITSU. MAURICES PROJECT MANAGER SHALL COORDINATE INSTALLATION WITH FUJITSU. INSTALLATION TO TAKE PLACE 1 WEEK PRIOR TO STORE PUNCH DATE. POS EQUIPMENT INSTALL (PROVIDED BY FUJITSU) NOTES: ELECTRICAL CONTRACTOR SHALL INSTALL PHONE JACKS WITH WIRING BACK TO 66 PUNCH DOWN BLOCK ALL SUPPLIED AND INSTALLED BY ELECTRICAL CONTRACTOR 2-3 WEEKS WITHIN START OF STORE CONSTRUCTION. CONTACT MAURICES IF PUNCH DOWN TOOL IS NOT AVAILABLE FOR FURTHER INSTALLATION INSTRUCTIONS. ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO HOOK UP VPN EQUIPMENT (MODEM AND ROUTER) SUPPLIED BY MAURICES ON P05 EQUIPMENT BOARD IN NON -SALES AREA. SEE POS EQUIPMENT INSTALLATION DETAIL. ELECTRICAL CONTRACTOR SHALL COORDINATE WITH SCOTT BRICKLES AT 218-121-8431 EXT. 3151, OR MATT GERARD AT MAURICES AT 218-121-8431 EXT. 31% FOR INSTALLATION OF THE VPN EQUIPMENT AND ANY PHONE LINE QUESTIONS ADJACENT TENANT (N.I.GJ PlayNet400work 0 COMBO PLAYER ZONE ZONE 2 TOA BG -1120 MIXER AMPLIFIER NAM WOO MELD 5100 5101 TYPE ATLAS SOUND FAF62T LOCATION TAP RETAIL STORE 4W TYPE 031 ATLAS SOUND FAP62T LOCATION TAP DRESSING ROOMS 4YV TYPE LOCATION TAP 50UNDTUSE 5M400i ENTRY DOOR SW E.G. SHALL INSTALL VOWME CONTROLS AT MANAGERS DESK AT 48" AFF WHERE NOTED ON E-4, AND LABEL PLAYNETWORK WIRING DIAGRAM MUSIC SYSTEM BY PLAYNETWORK SUPPLIED BY MAURICES INSTALLED BY E.G. INSTALLLATION MANUALS WILL BE PROVIDED WITH SYSTEM. E.G. TO PROVIDE 16 GAUGE, 2 CONDUCTOR PLENUM RATED WIRE FOR INSTALLATION OF THE SPEAKERD. THE PHONE it IS 1 -888 -561 -PLAY 0529). tHEY CAN THEN CHOOSE 1 FOR CUSTOMER SERVICE AND THEY WILL BE ABLE TO GET THE HELP THAT THEY NEED. ADJACENT TENANT (N.I.G.) =<A112 AX T-� BULLETIN BOARD L ----J II1 BUZ7 REFER TO "BUZZER SYSTEM ONE -LINE" DETAIL ON THIS SHEET FOR WIRING INSTRUCTIONS. 01 I 1 r L_ _ EQUIPMENT MANAGER'S DESK CAR, TABLE E.G. SHALL WIRE SPEAKERS BACK TO MANAGER. DESK FOR FINAL CONNECTION TO MUSIC SYSTEM. (FITTING ROOM SHALL BE CONNECTED SEPARATE FROM SALES AREA) E.G. SHALL WIRE SPEAKERS BACK TO MGR. DESK FOR FINAL CONNNECTION TO MUSIC SYSTEM. (FITTING ROOM SHALL BE CONNECTED SEPARATE FROM SALES AREA) 18 18 BUZZER, REFER TO "BUZZER SYSTEM ONE -LINE" DETAIL ON THIS SHEET FOR WIRING INSTRUCTIONS. II 18 E.G. SHALL WIRE SPEAKERS BACK TO MANAGER. DESK FOR FINAL CONNECTION TO MUSIC SYSTEM. (FITTING ROOM SHALL BE CONNECTED SEPARATE FROM SALES AREA) 18 18 18 18 COL LOW VOLTAGE PLAN SCALE:1/4" =1'-0" COL ADJACENT TENANT M.I.G.) 1 1' COL EXISTING MALL CONCOURSE pE pARAT'E MT AND AppRovAL REQUIRED 3' 5' 0 RECEIVED CITY OF TUKWILA AUG 1 1 2013 ERMIT CENTER 10' 2' 4' SCALE: y" =1'-0" I W N W 0 LO L.L 0o W W z M co !— ` 1 = N W D co J r 0 J N T-- 0 C) z z_ cc w w z_ C5 z W0 Wo -� 0 w Z WtA LO Lf) LC) Co LL O LO LO LO LO I- E 0 v c) 0 U) E 2 i N E 0 0 U 0 2 L co -C 0 ._ - c0 Q W 2 00 W o) z F_ W Vou50 F- D Eli W U1Nt/) Co O a t/) J —J JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC / MD -SS / CJ APPROVED BY: XX REVISIONS: 4_OW VOLTAGE PLAN SHEET E-4 ADJACENT TENANT M.I.G.) 1.12 240 1.15 119 115 L1/9 L1/7 L1/4 L1/4 L1/5 L1/7 1.i2 L17 1.12 Lk 241 � �� -� 9 215 249 243 67 L12 11.9 L14 L19 245 211 242 211 218 224 211 215 212 218 212 245 L19 114 110 Lg7 Lg7 L68 131 L16 21 248 4 HALLWAY 249 ,K 1.8 1;3 1. 6 110 L1/5 112 119 Lb 119 L1/1 L1/5 119 Lib L10 114 1.19 + L14 1116 1.1/8 L 7 7 2122 246 1.18 1)2 1I7 *do OAdML 6 L 2 L;8 244 21 242 dM 219 213 226 P. 213 21 214 248 2A1 15 1. 9 L 4 141 141 411 04 1.9 14 240 247 212 216 219 210 218 212 244 L 6 115 11 246 215 219 222 211 218 214 248 242 06 Lk L 7 L 5 L 4 L 5 1. 9 L 3 L 9 244 210 216 2 O 2A1 21f 3 210 216 211 245 L�8 L31 1.1 111 1.39 08 09 L�2 L�6 L 2 L�7 243 248 213 215 216 213 248 131 L i lilt, 1 11 63 ik 21 214 gg 08 11 1.1 04 08 05 03 d4 06 114 11 11 05 A gm A A gg 06 d4 d4 08 04 1.118 1I7 dko d4 h tia 149 118 w 07 L66 2., ,� 31 ADJACENT TENANT M.I.G.) 231 242 'A' . 2.1 2115 2118 216 269 248 245 217 2110` 239 34 33 2 i 2/13 2.2.4 218 211 233 238 267 .EL + 2117 291 is 3.13 3.19 I 3.18 319 238 L14 2110 265 249 311 311 38 330 38 30 347 E19 2115 2.10 314 317 348 335 337 336 38 316 II 37. 1+41 335 342 345 348 3.18 1+ 332 238 2116 242 313 314 263 243 348 31 332 NON -SALES 32 38 333 336 339 3.1 343 346 3+49 312 396 339 3b1 3112 3b1 1+41 3+47 331 163 365 317 348 A 31 363 366 368 369 3419 367 267 318 34 338 119 3171/1 1111 3.112 3113 a1133.14 a1/4 31/6 31/8 1118 3117 1114 2118 243 332 149 314 3/7 346 343 141 440 440 440 339 339 339 349 349 339 338 336 332 344 240 3.19 316 1113 316 147 444 418 411 412 411 411 411 410 410 410 410 449 446 41 a 242 a13 311 3//8 112 443 410 415 418 41 410 410 41 410 440 440 41 419 416 410 411 243 142 311 358 343 445 413 419 413 4125 417 417 418 419 419 430 430 418 414 411 44 23�0 3138 3,68 336 330 413 4W E4 417 4{ 4 100 412 414 43{{5 416 4117 4{37 43,5 41 414 413 339 3.119V 215 1 ++ r. 419' 4 3 4.3{6 4.38 4.40 4.41 4.41 419 43}4' 447 416 410 331 2//6 32 3.12 319 3//4 317 347 446 414 410 415 411 415 418 41 412 412 419 414 415 414 319 1119 216 310 38317 3113//435335413 411 41741341941;1417419418415410 4114 3321113 214 218 315 311 316 347 319 310 349 117 415 412 419.413 417 44041110 412 4{10 3134 366 ale 319 A/ 414 41U 414 416 4b 412 4.06 339 /2 312 217 266 210 235 317 316 38 3..o 330338317316313318332335335a91315a1/8318343316 t -.c .�' •a� HEM 349 14 334 / 310 14 35 VVEM 3t1 3+4 316 310 3.4 335 330 34 335 33.0 3.1 315 3112 3.15 334 3114 146 335 3a 0 338 314 3.12 310 148 3417 344 11/5 310 331 317 318 1113 333 31/6 317 46-317-117-1118-112-A-516-1 342 31 EM 313 311 314 Al 313 321 37 O4 l 3 # 315343 3436314313 3 353102 / 3 d 3t40 31'0 313 2. / 2..6 HEM 2.18 216 2t 214 216 219 2#17 278 2 2.32 2b9 2,15 215 2 2##}1 218 213 1. 2 287 219 2 266 2#1- 217 # 10 231 266 212 213 2.17 2 340 314 317 317 HEM n O n a 5 A A A 2A8 11 Lk L#98 1,#88 L 1.65 1330 L36 # 2.32 2#65 2 214 231 2118 2A7 L#% 1.62 L#66 L31 113 L}5 298 290 211 218 2 2.39 2 214 210 1.82 1 136 138 10 2. ,5 266 2 2. /063430 u HEM 3 0 n 7 O n 1 116 LtL95214all 2182 A A 2162102 inj L90 �f ) 217 2!4 235 239 232 21 250 215 237 23521921021123 162 148 L35 L28 1.29 138 II 111 170 176 L32 L91 L19 eir 1.98 L L65 L L L68 183 195 2 210 eh 232 244 2t24 1 210 a1a#t��330 32a4oa14 330 3,119 335 316 3117 3 6 213 317 316 282 297 317 2.33 217 298 2.13 259 210 PEM SALES PEM 217 A 2 217 O C 0 0 f I OPEM 47 252 256 216 278 A 295 A 297 293 285 235 d2 217 x --= 6 2A4 L88 L 4 L66 L69 L 2 2�7 2 2t 2b 20 2t tk # # ## # F.. td# 218 2 2 6 2 2 244 2 2h5 2 3 2 2 219 218 L 1.19 115 139 L11 132 LI7 111 111 2t 211 231 231 236 240 247 217 2.15 270 273 2.32 219 PEM icy AtirA Tzsifiviii Niipr 7922122 PEM 214 213 279 313 215 282 215 O 212 ?0 232 211 239 13L15 L72 110L33 211 214 2.16 236 212 181 1.62 115 2.12 258 252 212 3 L13 L15 L18 115 I 111 263215 2.1615 2 25# 6 262 268 272 212 252 212 ato 282 213 2b0 245 A a - 2#14�� 213 1.338 1#333 1#65 29 184 # # # 215 L98 L38 1#74 L60 1#54 1#59 2� 2 235 216 235 195 188 L1! 132 159 Luz Li3 119 u u u PEM 0 DXF file created by LitePro 2.013 on 8/21/2013 B18:18 A V ADJACENT TENANT M.I.G.) CALCULATIIN SUMMARY AREA \AME DIMENS]INS GRID / TYPE W PTS SPAC GAUP AVE MAX v[\ NAX/NIN AVE/SIN SALES 102J0x3860x11,00Ft New Grid / H -H 553 1.00 (=) 25 3.6 1.2 3,0 21 \I\ -SALES 23,80x33120x12,50Ft \ew Grip / H -H 444 1.00 C+> 3.6 4,4 2.2 2.0 1,7 HALLWAY 5160x510x1250Ft New Grid / H H 260 1.00 C+) 2,0 2.3 1,4 1.6 1.4 IVDIIR (0612 -XXX) Wv[\AIRE SCHEDULE TYP SYvBIL DESCRIPTIIN LAMP LUME\S NIU\TI\G/BALLAST LLF QTY HEN vERCURY 2X2 REC P (1) "2XEM" 54E-240- 11' IAX-16-ELBUNI EM (2) F40BX 1350 0.77 5 PEM HETALUX 2X4 (1) "F3" 2EP3GX-332S361-UNI-ELB REC P 11' (3) F132/T8 1350 079 6 WVEv NERCURY 4SKIP 12.5' (ll "Fl" 4' STRIP NM132-ICT-C ELB-UVI E (1) F132/41K 1200 0,80 9 LIGHTING PLAN SCALE: 1/4" = 1'-0" o SEPARATE PERMIT AND APPROVAL REQUIRED RECEIVED CITY OF TUKWILA AUG 2 3 2013 I- W N Wo 0 O0 cc wW Q.zr �zce) ft( Z N W f -r E2, w. N 0 r ul ul714; ' O EE O 0 I') O LAD 11 LAD 2 O JOB NO. 2170 DATE: 08-21-13 STORE TEAM: MC / MD -SS / CJ APPROVED BY : XX REVISIONS: REV *2 5-21-2013 JEH EGRESS PHOTOMETRIC PLAN SHEET E-5 OF 23 SHEETS 0 iii IIIIIHH!IHIHIII RESTROOM CEILING PLAN PROGRAMMABLE THERMOSTATS "HONEYWELL" #T7351F2010 THERMOSTAT. MAURICES SHALL FURNISH, MECHANICAL CONTRACTOR INSTALL AND PROGRAM T -STATS FOR EACH UNIT AS SHOWN ON PLAN AS FOLLOWS: • H.VA.C.- UNITS) SHALL "START UP" (OCCUPIED MODE), MONDAY THRU SUNDAY (7 -DAYS) BY MALL/STORE OPENING TIME AND "SETBACK" (UNOCCUPIED MODE) AT MALL/STORE CLOSING TIME. CONTRACTOR SHALL VERIFY STORE OPERATING HOURS WITH STORE MANAGER OR MALL MANAGEMENT. • IF MULTIPLE UNITS EXIST, START EACH ONE UP AT INTERVALS OF 15 MINUTES APART AND HAVE ALL UNITS OPERATING BY ONE HOUR AFTER OPENING. • OCCUPIED SPACE TEMPERATURE SETTINGS - SET POINT FOR COOLING SHALL BE 14 DEG.F.. SET POINT FOR HEATING SHALL BE 68 DEG. F. • UNOCCUPIED SPACE TEMPERATURE SETTINGS - SET POINT FOR COOLING SHALL BE Q5 DEG. F.. SET POINT FOR HEATING SHALL BE 55 DEG. F. • THERMOSTAT CONFIGURATION SWITCHES OR PROGRAM SETTINGS, SHALL BE SET FOR: FAHRENHEIT TEMPERATURE FORMAT, 12 -HOUR TIME DISPLAY AND INTERMITTENT FAN CONTROL. CONFIGURATION SWITCHES AND/OR PROGRAM SETTINGS SHALL BE SET FOR STAGING CONTROL APPROPRIATE FOR THE ASSOCIATED H.VA.C. UNIT. • AFTER T -STATS ARE PROGRAMMED - ENGAGE "KEYPAD LOCKOUT" TO PREVENT TAMPERING A5 DESCRIBED IN THE INSTALLATIOWOPERATING MANUAL. • THE PROGRAMMABLE THERMOSTAT(S) SHALL CONTROL ALL HEATING/COOLING AND "SET BACK" FUNCTIONS OF THE H.VA.C. EQUIPMENT. NOTES: I. MECHANICAL CONTRACTOR SHALL VISIT SITE AND VERIFY EXISTING CONDITIONS. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL MECHANICAL EQUIPMENT THAT 15 NOT BEING REUSED. NOTHING SHALL BE ABANDONED IN PLACE. 2. CONTRACTORS TO TURN OFF HVAC, OR COVER ALL RETURN AIR GRILLES WITH PLASTIC OR FILTERING MATERIAL DURING PERIODS OF DEMOLITION AND SANDING OF GYPSUM BOARD TO PREVENT EXCESS DUST FROM ENTERING HVAC SYSTEM. FIRE SPRINKLER SYSTEM: THE LANDLORD APPROVED FIRE SPRINKLER CONTRACTOR SHALL SUBMIT A COMPLETE SPRINKLER/FIRE PROTECTION PLAN FOR THE TENANT SPACE INCLUDING LOCATION AND TYPE OF ALL SPRINKLER HEADS, CHANGES TO EXISTING SPRINKLER MAINS OR BRANCH PIPING, AND LOCATION AND TYPE OF REQUIRED ALARM DEVICES. ALL WORK SHALL CONFORM TO N.F.PA. AND LOCAL FIRE OFFICIAL REQUIREMENTS. ALL WORK SHALL BE SCHEDULED WITH LANDLORD'S FIELD REPRESENTATIVE. ALL SYSTEMS SHALL BE CHARGED AND OPERATIONAL WHEN THE CONTRACTOR 15 NOT ON THE PREMISES. LANDLORD'S "FIRE PROTECTION DESIGN CRITERIA" FOR FURTHER DIRECTION AND REQUIREMENTS. (TYP.) MECHANICAL PLAN 0 1' 5' 10' 2' 4' / �I SCALE: Y 11 : l'-0" MECHANICAL GENERAL NOTES: I. ALL WORK SHALL BE IN ACCORDANCE WI/LOCAL, COUNTY AND FEDERAL CODES $ REGULATIONS. 2. CONTRACTOR SHALL VISIT SITE AND BE FULLY AWARE OF ALL EXISTING CONDITIONS PRIOR TO PROPOSAL. 3. FIELD VERIFY ALL SYSTEMS AND REPORT DISCREPANCIES TO MAURICES PROJECT MANAGER FOR RESOLUTION. 4. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED UTILITY SERVICE UPGRADES, INSPECTIONS AND PERMITS. 5. CONTRACTOR SHALL COORDINATE ALL CUTTING, PATCHING AND NEW ROOF PENETRATIONS WITH LANDLORD AND/OR LANDLORD'S ROOFING CONTRACTOR. b. CONTRACTOR SHALL COORDINATE ALL WORK WITH ARCHITECTURAL, ELECTRICAL AND STRUCTURAL DRAWINGS. 1. CONTRACTOR SHALL PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR, EXCEPT AS NOTED, A5 NECESSARY FOR A COMPLETE WORKABLE SYSTEM. 8. CONTRACTOR SHALL GUARANTEE THAT WORK DONE UNDER THIS SPECIFICATION WILL BE FREE FROM FAULTY MATERIALS OR WORKMANSHIP AND HEREBY AGREES TO REPAIR OR REPLACE ANY SYSTEM IN SAID WORK FOR A PERIOD OF ONE YEAR. 4. BALANCING CONTRACTOR SHALL TEST AND BALANCE ALL EQUIPMENT TO PERFORM AND DELIVER SPECIFIED QUANTITIES - PROVIDE BALANCE REPORT TO CODE OFFICIALS, LANDLORD AND MAURICES, INC.. 10. CONTRACTOR SHALL SUBMIT 2 -SETS OF SHOP DRAWINGS AND MANUFACTURERS CATALOGS OR BROCHURES ON NEW PRODUCTS FOR APPROVAL BY THE ARCHITECT. II. FLEX DUCT SHALL NOT EXCEED 1 -LIN. FEET. NO FIBERGLASS DUCTWORK ALLOWED -- ALL RIGID DUCTWORK SHALL BE SHEET METAL. 12. ALL ELECTRIC EQUIPMENT SHALL BE LISTED BY UNDERWRITERS LABS. 13. REFER TO LANDLORD'S "TENANT CRITERIA", AND BASE BUILDING PLANS FOR FURTHER INFORMATION AND DIRECTION. COORDINATE THE EXTENSION, MODIFICATION, FINAL CONNECTIONS AND TESTING OF ALL SYSTEMS WITH THE LANDLORD'S FIELD REPRESENTATIVE. MEGHNIGAL CODED NOTES (TYP) M0AURIGES SHALL FURNISH AND MECHANICAL CONTRACTOR SHALL INSTALL A NEW HONEYWELL 1 DAY PROGRAMMABLE THERMOSTAT I AT 5 FT. ABOVE FINISHED FLOOR. COORDINATE EXACT LOCATION WITH GENERAL CONTRACTOR. THERMOSTAT MUST BE FULLY COMPATIBLE WITH HVAC UNIT USED FOR PROJECT, COORDINATE TYPE WITH UNIT MANUFACTURER. O GENERAL CONTRACTOR SHALL REUSE EXISTING ROOF TOP UNIT (EX. RTU -2). PROVIDE 3 SETS OF 2" FILTERS, CHANGE FILTER AFTER FINAL STORE CLEANING AND AGAIN PRIOR TO AIR BALANCE. CHEMICALLY CLEAN COILS, REBALANCE FAN AND REPLACE BELTS, REPLACE/REPAIR ANY DEFECTIVE PARTS. GREASE AND/OR REPLACE (IF REQUIRED) FAN BEARINGS. CHECK CONTROLS FOR PROPER OPERATION AND MOTOR FOR PROPER FAN PERFORMANCE. CLEAN AND/OR REPLACE CONDENSATE LINE AS REQUIRED. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. 03 TERMINATE EXISTING DUCTWORK AT THIS POINT AND CAP END OF DUCT AIRTIGHT. OREUSE EXISTING DUCT MOUNTED RETURN AIR SMOKE DETECTOR. CLEAN, INSPECT AND REPAIR AS REQUIRED FOR PROPER OPERATION. 0 EF -I: MECHANICAL CONTRACTOR TO PROVIDE NEW EXHAUST FAN TO REPLACE EXISTING, COMPLETE WITH INTEGRAL BACKDRAFT DAMPER. EXHAUST CAPACITY SHALL BE 15 CFM AT 05" S.P. INSTALL AND SECURE PER MANUFACTURER'S INSTRUCTIONS. CONNECT TO EXISTING EXHAUST DUCT SERVING TOILET ROOM. 0 ZD -I: ZONE DAMPER, TRANSFORMER, AND THERMOSTAT FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. YOUNG'S REGULATOR: MODEL #4010 -PO ROUND 2 -POSITION DAMPER, THERMOSTAT T312, TRANSFORMER #3035 24V/120 40VA. REFER TO SHEET E -I FOR J -BOX LOCATION ACCESSIBLE IN PLENUM NEAR ZONE DAMPER AND INSTALL 24V/120V40VA TRANSFORMER. MECHANICAL CONTRACTOR TO FURNISH AND INSTALL THREE CONDUCTOR PLENUM RATED SHIELDED, 24V CONTROL WIRE BETWEEN TRANSFORMER, THERMOSTAT AND DAMPER MOTOR A5 DIAGRAMED ON M-2 ZONE DAMPER DETAIL (WHERE REQUIRED BY CODE, THE MECHANICAL CONTRACTOR IS TO INSTALL TEMPERATURE CONTROL WIRING IN CONDUIT. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL CONDUIT WITH FULL WIRE) ELECTRICAL CONTRACTOR TO PROVIDE 120V POWER TO TRANSFORMER AS INDICATED ON SHEET E-2. INSTALL THERMOSTAT AT 48" ABOVE FINISHED FLOOR. OEXISTING 5A $ RA DUCTS SHALL BE REUSED A5 NOTED. CLEAN, INSPECT AND REPAIR DUCTS AS REQUIRED. SEAL UNUSED OPENINGS AIRTIGHT. REPAIR DAMAGED INSULATION IN KIND. REPAIR/REPLACE HANGERS OTOILET ROOM FIXTURES TO REMAIN AND BE REUSED. CLEAN, INSPECT, REFURBISH, AND REPAIR TO LIKE NEW CONDITION. O GENERAL CONTRACTOR SHALL REUSE AS MUCH A5 POSSIBLE FROM THE EXISTING SPRINKLER SYSTEM AND ALARM SYSTEM. COORDINATE WITH LANDLORD. THE SPRINKLER HEADS IN THE STORE FRONT AND SALES AREA ARE TO BE RECESSED AND WHITE. MODIFY SYSTEM AS REQUIRED TO MEET CODE. PROVIDE INSPECTIONS TEST CONNECTION PER LANDLORD REQUIREMENTS. COORDINATE WITH LANDLORD AND AUTHORITY HAVING JURISDICTION. 10 SPRINKLER HEADS SHOWN FOR REFERENCE ONLY. FIRE PROTECTION PROFESSIONAL TO DETERMINE ACTUAL AMOUNT AND LOCATION OF HEADS. SPRINKLER HEADS SHALL BE LINED UP WITH LIGHTS. COORDINATE WITH LANDLORD AND TENANT. CD MOUNT TRANSFER GRILLE AS HIGH AS POSSIBLE. 12 REPLACE EXISTING ROOFTOP UNIT WITH NEW UNIT IN SAME LOCATION FIELD VERIFY EXACT LOCATION AND ORIENTATION OF EXISTING UNIT PRIOR TO BID/CONSTRUCTION. LANDLORD TO INSTALL AN ELECTRIC COOLING/GAS HEATING ROOFTOP UNIT. FIELD VERIFY EXACT LOCATION AND SIZE. PROVIDE RTU WITH 3 SETS OF FILTERS. CHANGE FILTER AFTER FINAL STORE CLEANING AND AGAIN PRIOR TO AIR BALANCE. SEE ROOFTOP HVAC UNIT SCHEDULE FOR FURTHER INFORMATION. 13 PROVIDE SUPPLY DEMAND CONTROL VENTILATION WITH NEW TRANE "RTU -I". PROVIDE AND INSTALL CO2 SENSOR AS SHOWN ON PLANS. MOUNT NEXT TO THERMOSTAT. 14 MAKE NEW CONNECTIONS BELOW ROOF TO EXISTING SUPPLY AND RETURN DUCTWORK. RECONFIGURE EXISTING DUCTWORK AS NECESSARY TO MAKE NEW CONNECTION. FIELD VERIFYSIZEAND LOCATION OF EXISTING DUCTWORK PRIOR TO BID/CONSTRUCTION. 15 UH -h HORIZONTAL PROJECTION UNIT HEATER FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR WHERE SHOWN ON PLANS. UNIT HEATER TO BE UL. LISTED AND HAVE A HEATING CAPACITY OF 3.0 KW AT 208V., I PH., WITH SELF CONTAINED THERMOSTAT SET AT 68 DEGREES F. SUSPEND UNIT HEATER FROM THE STRUCTURE 6" BELOW LOWEST STRUCTURAL MEMBER. COORDINATE EXACT LOCATION WITH CONSTRUCTION MANAGER AND PROVIDE ACCESS FOR SERVICE. .40 (EX)RTU-2 NOTE: I. MECHANICAL CONTRACTOR SHALL REUSE EXISTING DUCTWORK WHICH IS IN GOOD CONDITION TO THE GREATEST EXTENT POSSIBLE. CAP UNUSED OPENINGS. INSPECT AND REPAIR LEAKS, INSULATION AND HANGERS A5 REQUIRED. v SYMBOLS & ABBREVIATIONS LEGEND Q THERMOSTAT QS SENSOR SD DUCT SMOKE DETECTOR Jb-- UNDERCUT DOOR 2 C--2 2 J 2 I!I 0 0 X"45 AB. A/C AD. AFF. AHU. ARCH. BDD. DUCT OFFSET SUPPLY DUCT - UP SUPPLY DUCT - DN RA OR EXH. DUCT UP RA OR EXH. DUCT DN ELBOW TURNING VANES FIRE DAMPER (F.D) MANUAL BALANCE DAMPER TRANSITION SUPPLY DIFFUSER RETURN GRILLE EXHAUST GRILLE SPIN -IN FITTING SPIN -IN FITTING IN/ MAN. BAL. DPR. CONNECT TO EXISTING UPRIGHT SPRINKLER HEAD RECESSED SPRINKLER HEAD CONCEALED SPRINKLER HEAD PENDANT SPRINKLER HEAD ROUND DUCT ABOVE AIR CONDITIONING ACCESS DOOR ABOVE FINISHED FLOOR AIR HANDLING UNIT ARCHITECT BACKDRAFT DPR. BEL. BLDG. CFM. CLG. CONT. CONTR. COORD. CUH. DIFF. DISC. DN. DPR. EA. EC. EX. EXH. F. DPR. FLEX. FLR. GC. HP. MAX. MCA. MECH. MFR. MIN. MOCP. MTD. NTS. OA. RA. RTU. SA. SEPARATE PEPMTAND APPI iVAL REQUIRED BELOW BUILDING CUBIC I ->=t1 PER MINUTE CEILING CONTINUATION CONTRACTOR COORDINATE CABINET UNIT HEATER DIFFUSER DISCONNECT DOWN DAMPER EACH ELECTRICAL CONTRACTOR EXISTING EXHAUST FIRE DAMPER FLEXIBLE FLOOR GENERAL CONTRACTOR HORSEPOWER MAXIMUM MAX CIRCIUT AMPACITY MECHANICAL MANUFACTURER MINIMUM MAX OVERCURRENT PROTECTION MOUNTED NOT TO SCALE OUTSIDE AIR RETURN AIR ROOFTOP UNIT SUPPLY AIR 5 r!KE EXHAUST AIR AL REC8IVgD CITY OF TUKWIL AUG 1 Z 2013 PERMIT CENTER co I W CV Wo LO • 0 ce co W W CLZ� \cc) w = N W t` J- 0 j Co 0 2 0 W Z_ —1 Lo ZLU W Z W� W O cD W0Z1- C7Lt LU \_eco LIIcncoI- JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: iIECHANICAL PLAN SHEET M-1 ifj".:for 22 SHEET I I I 11 II I I I I I I I I I I 0 (TYP) ® ®®( I I I 1 I I I I I it K Ir f■■■■■■■.■■■■■■■■■ I I I, I I I I I I I I I I I I HIII IIIA IIIIIIl 1 I I h 0 0 L j- I �,-` � RG -2 -- I I�� I I�� I I I I I I I I 5D-4 255 RTU -I OI hiilL0 I I l B J F1 I l D J I RQ I 0 O O L HI-, A24I I_ I I I 405 � I - e we Q ■�■ _ O 1 1 I A7- x0 —' 405t>"''''''''''`..„,,I 405 • M M M M I M M I 1i = t›...-----....,„„. —i- `- -- Q ® H \ '/■ TYP. () H I I 1 5P 'S I I i i 18 I I I I I Qs' SD -1 4os I I I I 5P is I I I- I OI 7 v I _ O I® II W 1111 111111 II I I I I I RG -I I �� I ��`1� RM -1 I ����1� I I •4 50-3 Q/ 5P C 18 �I I 12 � " `...y O 1 v ...11 ©� ®® 3750 G -M 15:p y I 210 I O I ►01 alf 1 I I p I I Orli" Orli �Irrj, \��41_r,� . © �' (Ex)16"A.) �a I nallin&� �/ I I NT -LT I RG- I I(TYP.) 12' 0 I I I RG- I I ®© -� JI I r to — —I- — .- -- -- I —� O I I I 12"m I M I CSI 11 - 10'1 ; O NT , I 911 O � � M M �pv11 -�� �� -LT p! I I I I I I ®��� 5D-2 � :`"'�• :-_,I ie ��no � © ---1 e M M M 1 P 12°� M I P `O 1 •T 250 !� .r` if 4) I — (EX)20" I �- -- I `OI NFt i EX. RTU -2 0I12 EX ib" d� ( ) —1 i-' / 1 ©� 2800 GFM (10 ® 1 1 ►� I I I (EX)I6"4y I (EX)12"0 I -J - ® I '� I I 12"� I I I I 12"0 I I I I I ,� I I I I It I I -.►1xI r ---- 1i 50-1 r ` I . . -B \__ ►. 1 I 12"� . . 1 .. ec0 \ 405 e - A tW\\ I _ , I (TYP.) I �.v,., CO . , 8I A-4 A-4' A-- A-4 v © • RG -2 RG- I 15D- 0 O I O 1 O 5D-1 I- I I I \\ SD- I ovr W l O 1:. I 018 1 405 I I 1® 405 l O 18 1 �i�a 415 Q(64 H I I I I II® rNrNtcD I0 O 3a I'\ IIg-� \ yI�-- I \ \ I >"''''---,„ P`� I =___ iMM=__ —_J 1.>-'"-----,_ P M I M M o ® \4 cl W II 5D-2' � LH RG -I I I I pi R-III0IIIIl I V.. 1 (Y) 1IlIIIIIIIIIIIIIIII111 I I 20I,,1'"R_1 I I` Oipm. i�© �© I 1©� �' I� J® O I I ©may�ir�� c == _ ____ L �i�y �i� I0 16"x12" � I I1 I 010 ' 16 x12" I ` 1 o'8 I I Qis 10 I 142110 OO I —�CI W JSD-I SD -1 5D -I 1' _t>"---...,„„ Ic. I I II I 1nI I I I alpir, ■ I 435 pi J • . 435 L_'M , . 1.,>''''"\ IY> I430 I 1II1 , QF 4 01 0 0 V A-12' A -30 A-24' IS 435 5D-3 ® �� 1 [A O I IFI I 0 I IPU t 0 LPU I OB IFI IF J IFI 1 �g—I SOB I IPICD —7-- LIQ I 1 I I 300 =w -- I I I I I I I 1 G J II © 0 co a ® 1 ® ' ' ® ' a ® ® T Q I I II(�I111I.II11,, II1I I, 1, II,III II I11I 1III111,I1I II �d ,"1 �'�®"�` I I I I I I2"� t © I 1 „ "® ' 121 . I I II 12"14) I I 12"4> I I 1\®I ® ESI - I I I I I I I I I P4 P4 (EX)24"xl6" VI (Ex, -I- I I I I I PROGRAMMABLE THERMOSTATS "HONEYWELL" #T7351F2010 THERMOSTAT. MAURICES SHALL FURNISH, MECHANICAL CONTRACTOR INSTALL AND PROGRAM T -STATS FOR EACH UNIT AS SHOWN ON PLAN AS FOLLOWS: • H.VA.C.- UNITS) SHALL "START UP" (OCCUPIED MODE), MONDAY THRU SUNDAY (7 -DAYS) BY MALL/STORE OPENING TIME AND "SETBACK" (UNOCCUPIED MODE) AT MALL/STORE CLOSING TIME. CONTRACTOR SHALL VERIFY STORE OPERATING HOURS WITH STORE MANAGER OR MALL MANAGEMENT. • IF MULTIPLE UNITS EXIST, START EACH ONE UP AT INTERVALS OF 15 MINUTES APART AND HAVE ALL UNITS OPERATING BY ONE HOUR AFTER OPENING. • OCCUPIED SPACE TEMPERATURE SETTINGS - SET POINT FOR COOLING SHALL BE 14 DEG.F.. SET POINT FOR HEATING SHALL BE 68 DEG. F. • UNOCCUPIED SPACE TEMPERATURE SETTINGS - SET POINT FOR COOLING SHALL BE Q5 DEG. F.. SET POINT FOR HEATING SHALL BE 55 DEG. F. • THERMOSTAT CONFIGURATION SWITCHES OR PROGRAM SETTINGS, SHALL BE SET FOR: FAHRENHEIT TEMPERATURE FORMAT, 12 -HOUR TIME DISPLAY AND INTERMITTENT FAN CONTROL. CONFIGURATION SWITCHES AND/OR PROGRAM SETTINGS SHALL BE SET FOR STAGING CONTROL APPROPRIATE FOR THE ASSOCIATED H.VA.C. UNIT. • AFTER T -STATS ARE PROGRAMMED - ENGAGE "KEYPAD LOCKOUT" TO PREVENT TAMPERING A5 DESCRIBED IN THE INSTALLATIOWOPERATING MANUAL. • THE PROGRAMMABLE THERMOSTAT(S) SHALL CONTROL ALL HEATING/COOLING AND "SET BACK" FUNCTIONS OF THE H.VA.C. EQUIPMENT. NOTES: I. MECHANICAL CONTRACTOR SHALL VISIT SITE AND VERIFY EXISTING CONDITIONS. MECHANICAL CONTRACTOR IS RESPONSIBLE FOR REMOVING ALL MECHANICAL EQUIPMENT THAT 15 NOT BEING REUSED. NOTHING SHALL BE ABANDONED IN PLACE. 2. CONTRACTORS TO TURN OFF HVAC, OR COVER ALL RETURN AIR GRILLES WITH PLASTIC OR FILTERING MATERIAL DURING PERIODS OF DEMOLITION AND SANDING OF GYPSUM BOARD TO PREVENT EXCESS DUST FROM ENTERING HVAC SYSTEM. FIRE SPRINKLER SYSTEM: THE LANDLORD APPROVED FIRE SPRINKLER CONTRACTOR SHALL SUBMIT A COMPLETE SPRINKLER/FIRE PROTECTION PLAN FOR THE TENANT SPACE INCLUDING LOCATION AND TYPE OF ALL SPRINKLER HEADS, CHANGES TO EXISTING SPRINKLER MAINS OR BRANCH PIPING, AND LOCATION AND TYPE OF REQUIRED ALARM DEVICES. ALL WORK SHALL CONFORM TO N.F.PA. AND LOCAL FIRE OFFICIAL REQUIREMENTS. ALL WORK SHALL BE SCHEDULED WITH LANDLORD'S FIELD REPRESENTATIVE. ALL SYSTEMS SHALL BE CHARGED AND OPERATIONAL WHEN THE CONTRACTOR 15 NOT ON THE PREMISES. LANDLORD'S "FIRE PROTECTION DESIGN CRITERIA" FOR FURTHER DIRECTION AND REQUIREMENTS. (TYP.) MECHANICAL PLAN 0 1' 5' 10' 2' 4' / �I SCALE: Y 11 : l'-0" MECHANICAL GENERAL NOTES: I. ALL WORK SHALL BE IN ACCORDANCE WI/LOCAL, COUNTY AND FEDERAL CODES $ REGULATIONS. 2. CONTRACTOR SHALL VISIT SITE AND BE FULLY AWARE OF ALL EXISTING CONDITIONS PRIOR TO PROPOSAL. 3. FIELD VERIFY ALL SYSTEMS AND REPORT DISCREPANCIES TO MAURICES PROJECT MANAGER FOR RESOLUTION. 4. CONTRACTOR SHALL OBTAIN AND PAY FOR ALL REQUIRED UTILITY SERVICE UPGRADES, INSPECTIONS AND PERMITS. 5. CONTRACTOR SHALL COORDINATE ALL CUTTING, PATCHING AND NEW ROOF PENETRATIONS WITH LANDLORD AND/OR LANDLORD'S ROOFING CONTRACTOR. b. CONTRACTOR SHALL COORDINATE ALL WORK WITH ARCHITECTURAL, ELECTRICAL AND STRUCTURAL DRAWINGS. 1. CONTRACTOR SHALL PROVIDE ALL MATERIALS, EQUIPMENT AND LABOR, EXCEPT AS NOTED, A5 NECESSARY FOR A COMPLETE WORKABLE SYSTEM. 8. CONTRACTOR SHALL GUARANTEE THAT WORK DONE UNDER THIS SPECIFICATION WILL BE FREE FROM FAULTY MATERIALS OR WORKMANSHIP AND HEREBY AGREES TO REPAIR OR REPLACE ANY SYSTEM IN SAID WORK FOR A PERIOD OF ONE YEAR. 4. BALANCING CONTRACTOR SHALL TEST AND BALANCE ALL EQUIPMENT TO PERFORM AND DELIVER SPECIFIED QUANTITIES - PROVIDE BALANCE REPORT TO CODE OFFICIALS, LANDLORD AND MAURICES, INC.. 10. CONTRACTOR SHALL SUBMIT 2 -SETS OF SHOP DRAWINGS AND MANUFACTURERS CATALOGS OR BROCHURES ON NEW PRODUCTS FOR APPROVAL BY THE ARCHITECT. II. FLEX DUCT SHALL NOT EXCEED 1 -LIN. FEET. NO FIBERGLASS DUCTWORK ALLOWED -- ALL RIGID DUCTWORK SHALL BE SHEET METAL. 12. ALL ELECTRIC EQUIPMENT SHALL BE LISTED BY UNDERWRITERS LABS. 13. REFER TO LANDLORD'S "TENANT CRITERIA", AND BASE BUILDING PLANS FOR FURTHER INFORMATION AND DIRECTION. COORDINATE THE EXTENSION, MODIFICATION, FINAL CONNECTIONS AND TESTING OF ALL SYSTEMS WITH THE LANDLORD'S FIELD REPRESENTATIVE. MEGHNIGAL CODED NOTES (TYP) M0AURIGES SHALL FURNISH AND MECHANICAL CONTRACTOR SHALL INSTALL A NEW HONEYWELL 1 DAY PROGRAMMABLE THERMOSTAT I AT 5 FT. ABOVE FINISHED FLOOR. COORDINATE EXACT LOCATION WITH GENERAL CONTRACTOR. THERMOSTAT MUST BE FULLY COMPATIBLE WITH HVAC UNIT USED FOR PROJECT, COORDINATE TYPE WITH UNIT MANUFACTURER. O GENERAL CONTRACTOR SHALL REUSE EXISTING ROOF TOP UNIT (EX. RTU -2). PROVIDE 3 SETS OF 2" FILTERS, CHANGE FILTER AFTER FINAL STORE CLEANING AND AGAIN PRIOR TO AIR BALANCE. CHEMICALLY CLEAN COILS, REBALANCE FAN AND REPLACE BELTS, REPLACE/REPAIR ANY DEFECTIVE PARTS. GREASE AND/OR REPLACE (IF REQUIRED) FAN BEARINGS. CHECK CONTROLS FOR PROPER OPERATION AND MOTOR FOR PROPER FAN PERFORMANCE. CLEAN AND/OR REPLACE CONDENSATE LINE AS REQUIRED. FIELD VERIFY EXACT LOCATION AND REQUIREMENTS. 03 TERMINATE EXISTING DUCTWORK AT THIS POINT AND CAP END OF DUCT AIRTIGHT. OREUSE EXISTING DUCT MOUNTED RETURN AIR SMOKE DETECTOR. CLEAN, INSPECT AND REPAIR AS REQUIRED FOR PROPER OPERATION. 0 EF -I: MECHANICAL CONTRACTOR TO PROVIDE NEW EXHAUST FAN TO REPLACE EXISTING, COMPLETE WITH INTEGRAL BACKDRAFT DAMPER. EXHAUST CAPACITY SHALL BE 15 CFM AT 05" S.P. INSTALL AND SECURE PER MANUFACTURER'S INSTRUCTIONS. CONNECT TO EXISTING EXHAUST DUCT SERVING TOILET ROOM. 0 ZD -I: ZONE DAMPER, TRANSFORMER, AND THERMOSTAT FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. YOUNG'S REGULATOR: MODEL #4010 -PO ROUND 2 -POSITION DAMPER, THERMOSTAT T312, TRANSFORMER #3035 24V/120 40VA. REFER TO SHEET E -I FOR J -BOX LOCATION ACCESSIBLE IN PLENUM NEAR ZONE DAMPER AND INSTALL 24V/120V40VA TRANSFORMER. MECHANICAL CONTRACTOR TO FURNISH AND INSTALL THREE CONDUCTOR PLENUM RATED SHIELDED, 24V CONTROL WIRE BETWEEN TRANSFORMER, THERMOSTAT AND DAMPER MOTOR A5 DIAGRAMED ON M-2 ZONE DAMPER DETAIL (WHERE REQUIRED BY CODE, THE MECHANICAL CONTRACTOR IS TO INSTALL TEMPERATURE CONTROL WIRING IN CONDUIT. ELECTRICAL CONTRACTOR IS TO FURNISH AND INSTALL CONDUIT WITH FULL WIRE) ELECTRICAL CONTRACTOR TO PROVIDE 120V POWER TO TRANSFORMER AS INDICATED ON SHEET E-2. INSTALL THERMOSTAT AT 48" ABOVE FINISHED FLOOR. OEXISTING 5A $ RA DUCTS SHALL BE REUSED A5 NOTED. CLEAN, INSPECT AND REPAIR DUCTS AS REQUIRED. SEAL UNUSED OPENINGS AIRTIGHT. REPAIR DAMAGED INSULATION IN KIND. REPAIR/REPLACE HANGERS OTOILET ROOM FIXTURES TO REMAIN AND BE REUSED. CLEAN, INSPECT, REFURBISH, AND REPAIR TO LIKE NEW CONDITION. O GENERAL CONTRACTOR SHALL REUSE AS MUCH A5 POSSIBLE FROM THE EXISTING SPRINKLER SYSTEM AND ALARM SYSTEM. COORDINATE WITH LANDLORD. THE SPRINKLER HEADS IN THE STORE FRONT AND SALES AREA ARE TO BE RECESSED AND WHITE. MODIFY SYSTEM AS REQUIRED TO MEET CODE. PROVIDE INSPECTIONS TEST CONNECTION PER LANDLORD REQUIREMENTS. COORDINATE WITH LANDLORD AND AUTHORITY HAVING JURISDICTION. 10 SPRINKLER HEADS SHOWN FOR REFERENCE ONLY. FIRE PROTECTION PROFESSIONAL TO DETERMINE ACTUAL AMOUNT AND LOCATION OF HEADS. SPRINKLER HEADS SHALL BE LINED UP WITH LIGHTS. COORDINATE WITH LANDLORD AND TENANT. CD MOUNT TRANSFER GRILLE AS HIGH AS POSSIBLE. 12 REPLACE EXISTING ROOFTOP UNIT WITH NEW UNIT IN SAME LOCATION FIELD VERIFY EXACT LOCATION AND ORIENTATION OF EXISTING UNIT PRIOR TO BID/CONSTRUCTION. LANDLORD TO INSTALL AN ELECTRIC COOLING/GAS HEATING ROOFTOP UNIT. FIELD VERIFY EXACT LOCATION AND SIZE. PROVIDE RTU WITH 3 SETS OF FILTERS. CHANGE FILTER AFTER FINAL STORE CLEANING AND AGAIN PRIOR TO AIR BALANCE. SEE ROOFTOP HVAC UNIT SCHEDULE FOR FURTHER INFORMATION. 13 PROVIDE SUPPLY DEMAND CONTROL VENTILATION WITH NEW TRANE "RTU -I". PROVIDE AND INSTALL CO2 SENSOR AS SHOWN ON PLANS. MOUNT NEXT TO THERMOSTAT. 14 MAKE NEW CONNECTIONS BELOW ROOF TO EXISTING SUPPLY AND RETURN DUCTWORK. RECONFIGURE EXISTING DUCTWORK AS NECESSARY TO MAKE NEW CONNECTION. FIELD VERIFYSIZEAND LOCATION OF EXISTING DUCTWORK PRIOR TO BID/CONSTRUCTION. 15 UH -h HORIZONTAL PROJECTION UNIT HEATER FURNISHED AND INSTALLED BY THE MECHANICAL CONTRACTOR WHERE SHOWN ON PLANS. UNIT HEATER TO BE UL. LISTED AND HAVE A HEATING CAPACITY OF 3.0 KW AT 208V., I PH., WITH SELF CONTAINED THERMOSTAT SET AT 68 DEGREES F. SUSPEND UNIT HEATER FROM THE STRUCTURE 6" BELOW LOWEST STRUCTURAL MEMBER. COORDINATE EXACT LOCATION WITH CONSTRUCTION MANAGER AND PROVIDE ACCESS FOR SERVICE. .40 (EX)RTU-2 NOTE: I. MECHANICAL CONTRACTOR SHALL REUSE EXISTING DUCTWORK WHICH IS IN GOOD CONDITION TO THE GREATEST EXTENT POSSIBLE. CAP UNUSED OPENINGS. INSPECT AND REPAIR LEAKS, INSULATION AND HANGERS A5 REQUIRED. v SYMBOLS & ABBREVIATIONS LEGEND Q THERMOSTAT QS SENSOR SD DUCT SMOKE DETECTOR Jb-- UNDERCUT DOOR 2 C--2 2 J 2 I!I 0 0 X"45 AB. A/C AD. AFF. AHU. ARCH. BDD. DUCT OFFSET SUPPLY DUCT - UP SUPPLY DUCT - DN RA OR EXH. DUCT UP RA OR EXH. DUCT DN ELBOW TURNING VANES FIRE DAMPER (F.D) MANUAL BALANCE DAMPER TRANSITION SUPPLY DIFFUSER RETURN GRILLE EXHAUST GRILLE SPIN -IN FITTING SPIN -IN FITTING IN/ MAN. BAL. DPR. CONNECT TO EXISTING UPRIGHT SPRINKLER HEAD RECESSED SPRINKLER HEAD CONCEALED SPRINKLER HEAD PENDANT SPRINKLER HEAD ROUND DUCT ABOVE AIR CONDITIONING ACCESS DOOR ABOVE FINISHED FLOOR AIR HANDLING UNIT ARCHITECT BACKDRAFT DPR. BEL. BLDG. CFM. CLG. CONT. CONTR. COORD. CUH. DIFF. DISC. DN. DPR. EA. EC. EX. EXH. F. DPR. FLEX. FLR. GC. HP. MAX. MCA. MECH. MFR. MIN. MOCP. MTD. NTS. OA. RA. RTU. SA. SEPARATE PEPMTAND APPI iVAL REQUIRED BELOW BUILDING CUBIC I ->=t1 PER MINUTE CEILING CONTINUATION CONTRACTOR COORDINATE CABINET UNIT HEATER DIFFUSER DISCONNECT DOWN DAMPER EACH ELECTRICAL CONTRACTOR EXISTING EXHAUST FIRE DAMPER FLEXIBLE FLOOR GENERAL CONTRACTOR HORSEPOWER MAXIMUM MAX CIRCIUT AMPACITY MECHANICAL MANUFACTURER MINIMUM MAX OVERCURRENT PROTECTION MOUNTED NOT TO SCALE OUTSIDE AIR RETURN AIR ROOFTOP UNIT SUPPLY AIR 5 r!KE EXHAUST AIR AL REC8IVgD CITY OF TUKWIL AUG 1 Z 2013 PERMIT CENTER co I W CV Wo LO • 0 ce co W W CLZ� \cc) w = N W t` J- 0 j Co 0 2 0 W Z_ —1 Lo ZLU W Z W� W O cD W0Z1- C7Lt LU \_eco LIIcncoI- JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: iIECHANICAL PLAN SHEET M-1 ifj".:for 22 SHEET DIVISION FIFTEEN/MECHANICAL 15001 DESIGN INFORMATION NOTE: CARE SHOULD BE TAKEN TO AVOID MODIFICATION TO IN-PLACE SPRINKLER HEADS WHEREVER POSSIBLE. GENERAL NOTES: I. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS. 2. PATCH ALL OPENINGS IN WALLS, ROOFS, AND FLOORS TO MATCH EXISTING WHERE MECHANICAL EQUIPMENT, DUCTS, OR PIPES HAVE BEEN REMOVED. 3. PATCH OPENINGS IN DUCTS THAT ARE TO REMAIN ACTIVE AND HAVE HAD A SECTION OR BRANCH DUCT REMOVED. ALSO, REPAIR DUCT LINING 50 IT IS CONTINUOUS. 4. THE INSTALLATION OF NEV( DUCTS, PIPES, AND EQUIPMENT MAY REQUIRE THE REMOVAL OF EXISTING WALLS AND CEILINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING THESE WALLS AND/OR CEILINGS 50 THEY MATCH THE EXISTING WHERE NOT REPLACED UNDER ARCHITECTURAL DIVISION. 5. CONTRACTOR TO COORDINATE THE LOCATION OF ALL DUCTWORK AND DIFI•USCRS WITH LIGHTING PLAN PRIOR TO BEGINNING WORK. 6. MAXIMUM FLEXIBLE DUCT LENGTH NOT TO EXCEED 7'-0" OR AS REQUIRED BY LOCAL CODE, WHICHEVER 15 THE LEAST LENGTH. 1. MECHANICAL CONTRACTOR SHALL HAVE READ AND BE FAMILIAR WITH THE GENERAL AND ELECTRICAL SPECIFICATIONS AND PLANS. S. MECHANICAL CONTRACTOR SHALL PROVIDE "AS -BUILT" DRAWINGS OF ALL MECHANICAL SYSTEMS UPON COMPLETION OF WORK TO MAURICES INCORPORATED. NOTIFY MAURICES IN WRITING OF ANY DEVIATIONS FROM THE PLANS. MAJOR DEVIATIONS MUST BE APPROVED BY THE MECHANICAL ENGINEER IN WRITING BEFORE IMPLEMENTATION. SCOPE OF WORK: FURNISH ALL LABOR, EQUIPMENT, SUPPLIES 6 MATERIALS. PERFORM ALL OPERATIONS NECESSARY FOR THE INSTALLATION OF COMPLETE AND OPERABLE MECHANICAL SYSTEM. PROVE SATISFACTORY OPERATION OF ALL EQUIPMENT AND CONTROLS TO MAURICES. CHECK AND RECONDITION EXISTING MECHANICAL AND PLUMBING SYSTEMS FOR OPTIMUM PERFORMANCE DURING FUTURE USE. INFORM MAURICES AND LANDLORD, IN WRITING, OF ANY MAJOR MAINTENANCE AND/OR REPLACEMENT PROCEDURES ARE NECESSARY PRIOR TO UNDER TAKING SAME. EXCAVATION AND BACKFILL: DO ALL EXCAVATING AND BACKFILLING REQUIRED BY THE WORK IN THIS DIVISION. FOUNDATIONS AND SUPPORTS: FURNISH AND INSTALL ALL BASES AND SUPPORTS FOR MECHANICAL EQUIPMENT, UNLESS SPECIFIED OTHERWISE. IDENTIFICATIONS: I. MAIN DOMESTIC COLD WATER; MAIN DOMESTIC HOT WATER AND ALL GAS VALVES SHALL BE IDENTIFIED BY BRASS OR PLASTIC DISK. 2. ALL FIRE DAMPERS AND THEIR ACCESS DOORS SHALL BE IDENTIFIED BY PRINTED STENCIL SECURED TO THE ACCESS DOOR OR A LOCATION APPROVED BY MAURICES. BALANCING: AT THE COMPLETION OF THE INSTALLATION, THE MECHANICAL SYSTEM SHALL BE BALANCED BY THE CONTRACTOR. PROVIDE MAURICES WITH TABULATIONS. OPERATING AND MAINTENANCE INSTRUCTIONS: OPERATING AND MAINTENANCE INSTRUCTION SHALL BE DELIVERED TO THE MAURICES CONSTRUCTION REPRESENTATIVE ON COMPLETION OF THE WORK. MECHANICAL CONTRACTOR SHALL INSTRUCT THE STORE MANAGER ON OPERATION OF ALL EQUIPMENT UNDER HIS CONTRACT. ALL LIGHTING AND ELECTRICAL REQUIREMENTS SHALL TAKE PRECEDENCE OVER MECHANICAL REQUIREMENTS IN THAT NO MECHANICAL SYSTEM GRILLES, DIFFUSERS, OR DEVICES OF ANY NATURE SHALL PENETRATE THROUGH DECORATIVE FIXTURES, LIGHTING ELEMENTS, OR MIRRORS. COORDINATE LOCATIONS PRIOR TO INSTALLATION. GENERAL CONTRACTOR SHALL PROVIDE TENANT NAME AND SPACE NUMBER ON HVAC UNIT(S) AND ANY HVAC. RELATED APPENDAGES. REPLACE ALL FILTERS FOR EXISTING HVAC UNIT(5) BEING RETAINED AT END OF CONSTRUCTION. IMPORTANT: SEE ARCHITECTURAL SPECIFICATIONS AND DRAWINGS FOR ADDITIONAL INFORMATION. CLC TASK RESPONSIBILITY LIST ON SHEET Al OF THE ARCHITECTURAL DRAWINGS FOR BREAKDOWN OF TASK RESPONSIBILITIES. 15440 PLUMBING FIXTURES THE FOLLOWING FIXTURES OR EQUALS SHALL BE PROVIDED (OR RETAINED) IN THE RESTROOM(5) $ SHALL BE CONNECTED TO COLD WATER LINE $ SANITARY SEWER ROUGH -INS. PROVIDE ALL NECESSARY VENTS AND EXHAUSTS AND COORDINATE ALL ROOF CUTS WITH LANDLORD. PROVIDE SHUT-OFF VALVES AT EACH FIXTURE WATER SUPPLY LINE. INVESTIGATE ALL PLUMBING ELEMENTS EXISTING WITHIN THE LEASED AREA(S). NOTIFY MAURICES AND LANDLORD OF ANY EXISTING OR POTENTIAL FUTURE PROBLEM CONDITIONS. CLEAN, REPAIR, OR REPLACE ALL PLUMBING ELEMENTS (E.G., WC, LAV, ETC.) A5 REQUIRED. ALL FIXTURES MUST COMPLY WITH THE CANADIANS WITH DISABILITIES ACT. WHERE CODE PERMITS, CONTRACTOR SHALL RETROFIT EXISTING WATER CLOSETS WITH SEATS BY OLSONITE, OR EQUAL, A5 REQUIRED TO MODIFY EXISTING WATER CLOSETS TO MEET ADA REQUIREMENTS. WHERE FIXTURE REPLACEMENT IS NECESSARY, THE FOLLOWING FIXTURES SHALL BE USED: TAKE OFF SCREWED AND SEALED WITH DUCT SEALANT TO DUCT. CONICAL COLLAR BY MECH. CONTR. EXTERNAL INSULATION WHERE REQUIRED. INNER NYLON 66 DUCTSTRAP CLAMP. SHEET METAL SCREW AT INNER LINER. VOLUME DAMPER ADJUSTMENT. CEILING DIFFUSER (WITH FIRE DAMPER IF REQUIRED) NOTES: FLEXIBLE DUCT 15 TO BE USED FOR VERTICAL DROPS ONLY. RUNOUTS AND ELBOWS ARE TO BE SHEETMETAL DUCT. THE MECHANICAL CONTRACTOR MUST PROVIDE ADAPTERS FOR DIFFUSERS WITH SQUARE AND RECTANGULAR NECKS AS REQUIRED. INNER LINER TO BE SECURED TO COLLAR BY NYLON STRAP AND THREE SHEET METAL SCREWS TO PREVENT LINER FROM SLIPPING OFF COLLAR. MAXIMUM FLEX DUCT 15 1 FEET. CUT SMALL SLIT IN LINER AT DAMPER ADJUSTMENT A/STRING OR WIRE MARKER TO SHOW LOCATION. DIFFUSER CONNECTION DETAIL SCALE: NT5 SQUARE ELBOW ACCESS DOOR 3" MAX. DOUBLE THICKNESS VANES BRANCH DUCT L: 025xk 3" MIN. L: 025xW 3" MIN. RETURN TAP AIR FLOW 45 DEG L: 0.25xA 3" MIN. SUPPLY TAP AIR FLOW 45 DEG 2 R R/WMUSTBE GREATER THAN I. OR 111 EQUAL TO 1.5 NO TURNING VANES REQUIRED. I MANUAL AIR DAMPER V WITH LOCKING QUADRANT SUPPLY GRILLE WITH INTEGRAL VOLUME DAMPER SUPPLY TAP WITH SUPPLY GRILLE DUCT CONNECTION DETAIL SCALE: NTS ALTERNATE TO RECTANGULAR ELBOW WATER CLOSETS: (IF REPLACEMENT 15 REQUIRED) WHITE, VITREOUS CHINA, SIPHON JET, ELONGATED RIM WATER CLOSET WITH TANK AND TRIM, BACKFLOW PREVENTER, BOLT CAPS, AND ANGLE FLEXIBLE SUPPLY WITH STOP VALVE: KOHLER - "HIGHLINE" 1K -3427 -EB; AMERICAN STANDARD - "ELONGATED CADET" #2101.405; CRANE - "RADCLIFFE" #3-I44; ELDER - "EMBLEM" #011-1605; UNIVERSAL RUNDLE - "NEW CASTLE" #4021. HANDICAP HEIGHT A5 REQUIRED. SEATS WHITE, SOLID PLASTIC, OPEN FRONT SEAT, LESS COVER: OLSONITE #10 -CC; BENEKE #523; KOHLER #K -4610-C; BEMIS #1155-C; ELJER #124-0355; OLSONITE "HANDI-AID" #L-240/1.-242 OR SIMILAR. LAVATORY (IF REPLACEMENT 15 REQUIRED) WHITE, VITREOUS CHINA, WALL HUNG, 20" X IS" LAVATORY WITH BACK. G.P. ALL BRASS I-1/4" TRAP, SUPPLY AND WASTE FITTING. CONCEALED WALL CARRIER. MOUNT AS PER AMERICANS WITH DISIBILITIES ACT REQUIREMENTS FOR HANDICAP ACCESS WITH RIM HEIGHT AT 34" ABOVE FINICHCD FLOOR INSULATE TRAP AND HW SUPPLY. KOHLER - "GREENWICH" #K-2032; AMERICAN STANDARD - "LUCERNE" #0355.012; CRANE - "NORWICH" #I -114-S; ELJER - DELWYN #051-1545. PROVIDE PERFORATED STRAINER, ANGLE SUPPLIES # STOPS AND TRAP WITH CLEANOUT A5 SUPPLIED BY MANUFACTURER CARRIERS SHALL BE: JOSAM #17100; WADE #W-520; SMITH 4t700; ZURN ZR -1231. 15463 ELECTRIC WATER HEATER (IF REPLACEMENT 15 REQUIRED) ELECTRIC WATER HEATER SHALL BE LOCATED ON DECK ABOVE TOILET ROOM. "STATE" #P6-6-I0MS-K OR EQUAL, 6 -GALLON STORAGE CAPACITY. 120 VAC, I -PH., 1,650 WATTS, 5 GALLONS PER HR. RECOVERY AT 10 DEG. TEMP. RISE. PROVIDE BALL VALVES, DIELECTRIC UNIONS AND CANADIAN APPROVED T $ P RELIEF VALVE AND ALL OTHER ACCESSORIES AS SHOWN ON "Fl FCTRIC WATER HEATER DETAIL" AND AS REQUIRED FOR COMPLETE INSTALLATION. 15210 DUCT INSULATION I. DUCT INSULATION, FOR NEW DUCTWORK, SHALL BE I-1/2" FOIL FACED DUCT WRAP, MINIMUM R-5 AND/OR GREATER AS SPECIFIED ON 'BASE BUILDING" MECHANICAL PLANS AND SPECIFICATIONS OR AS PER EXISTING BUILDING STANDARD. 15320 FIRE PROTECTION SPRINKLER SYSTEMS FIRE SPRINKLER SYSTEM SHALL BE INSTALLED THROUGHOUT TENANT SPACE AND SHALL CONFORM TO ALL LANDLORD AND UNDERWRITER REQUIREMENTS. REFER TO GENERAL REQUIREMENTS. SPRINKLER SYSTEM SHALL HAVE CONFIGURATION A5 REQUIRED NOT TO INTERFERE WITH STORE FIXTURES, ELECTRICAL OR MECHANICAL WORK. FIRE SPRINKLER HEAD FINISH SHALL MATCH FINISH OF EXISTING FIRE HEADS IF EXISTING (FIELD VERIFY) OR AS PER BUILDING STANDARD IF NEW SYSTEM. (SEE TASK RESPONSIBILITY LIST). FIRE SPRINKLER SYSTEM SHALL BE MAINTAINED THROUGHOUT MAURICE5 SPACE. SPRINKLER SYSTEM SHALL BE MODIFIED, AS REQ., NOT TO INTERFERE WITH STORE FIXTURES, ELECTRICAL OR MECHANICAL WORK. SPRINKLER CONTRACTOR SHALL PROVIDE SPRINKLER DRAWING FOR LANDLORD'S APPROVAL PRIOR TO PROCEEDING WITH WORK. 15510 DUCTWORK PROVIDE ONE (OR MORE) SUPPLY AIR DUCT AND DIFFUSER(S) AT EACH FITTING ROOM BANK. PROVIDE AN ADJ. DAMPER IN ANY DUCTS THAT ARE EXISTING TO SERVICE AREA. MODIFY, FURNISH OR RELOCATE DUCTWORK, A5 REQUIRED OR AS SHOWN ON PLAN, TO SUPPLY AN AIR DISTRIBUTION SYSTEM FOR THE ENTIRE NEW STORE CONFIGURATION. DUCTWORK SHALL BE IN ACCORDANCE WITH SMACNA DUCT MANUAL, AIA FILE NO. 30-D-4. DUCTWORK MATERIALS: I. ALL DUCTWORK SHALL BE GALVANIZED STEEL EXCEPT AS OTHERWISE CALLED FOR 2. DUCTWORK INCLUDED IN ANY LIFE SAFETY OR SMOKE CONTROL SYSTEM SHALL BE GALVANIZED STEEL. 3. LOW VELOCITY FLEXIBLE DUCTS TO BE GENFLEX, WIREMOLD, THERMAFLEX, PORTODUCT OR CLECON WITH I" THICK INSULATION. ROUND DUCT CONNECTORS TO BE THERMAFLAIR III, GLENFLEX 5M -ID, CLEVAPAK DSC, OR EQUAL. THE FLEXIBLE DUCT MUST BE APPROVED BY THE LOCAL CODE AUTHORITY FOR THE SPECIFIC APPLICATION. DUCT INSULATION: DUCT INSULATION, FOR NEW DUCTWORK, SHALL BE I-1/2" FOIL FACED DUCT WRAP, MINIMUM R-5 AND/OR GREATER A5 SPECIFIED ON 'BASE BUILDING" MECHANICAL PLANS AND SPECIFICATIONS OR A5 PER EXISTING BUILDING STANDARD. ALL EXISTING DUCTWORK BEING REUSED SHALL BE THOROUGHLY CLEANED ON THE INSIDE PRIOR TO REUSE WHETHER RELOCATED OR IN ORIGINAL POSITION. 15115 DAMPERS FIRE DAMPERS SHALL BE FABRICATED $ INSTALLED IN ACCORDANCE WNL REQ., W/ACGE55 DOOR IN DUCT, FOLDING BLADE DAMPERS INFUSIBLE LINK, RUSKIN IBD OR EQUAL AS APPROVED BY LOCAL CODE AUTHORITY. 15132 REGISTERS, GRILLES, AND DIFFUSERS - A5 SPECIFIED ON SHEET M -I AND/OR AS FOLLOWS: CEILING DIFFUSER: FOUR-WAY, OFF-WHITE BAKED ENAMEL FINISH 4 ROUND NECK. TITUS #TMS; CARNES #SJ; KRUGER #1400. LIMA #150 FOR NON -SALES AREA ONLY. RA. GRILLE: PERFORATED FACE, OR A5 PER PLAN, OFF-WHITE BAKED ENAMEL FINISH. TITUS #PXP OR *PAR; TUTTLE BAILEY #CTPV; CARNES #43514; KRUGER #1116-A. 15150 MECHANICAL CONTROLS AND INSTRUMENTATION UNLESS OTHERWISE INDICATED, ANY REPLACEMENT MOTORS AND CONTROLS SHALL BE FURNISHED, SET IN PLACE, AND WIRED IN ACCORDANCE WITH THE FOLLOWING SCHEDULE. (MD 15 MECHANICAL DIVISION; ED 15 ELECTRICAL DIVISION.) IF FURNISHED AS PART OF FACTORY -WIRED EQUIPMENT, POWER WIRING ONLY BY ED. IF LINE THERMOSTATS, P.E. SWITCHES, TIME SWITCHES, ETC., CARRY THE FULL LOAD CURRENT TO ANY DEVICE, THEY SHALL BE FURNISHED BY THE MECHANICAL DIVISION AND SHALL BE SET IN PLACE AND CONNECTED UNDER THE ELECTRICAL DIVISION. WHERE SUCH ITEMS ARE AN INTEGRAL PART OF THE MECHANICAL EQUIPMENT, OR DIRECTLY ATTACHED TO DUCTS, PIPING, ETC., THEY SHALL BE SET IN PLACE UNDER THE MECHANICAL DIVISION AND CONNECTED BY THE ELECTRICAL DIVISION. IF THEY DO NOT CARRY THE FULL -LOAD CURRENT TO ANY MOTOR, THEY SHALL BE FURNISHED, SET IN PLACE, AND WIRED UNDER THE MECHANICAL DIVISION. CONTROL DEVICES CARRYING FULL -LOAD. CURRENT FURNISHED BY MECHANICAL AND WIRED BY ELECTRICAL SHALL BE LOCATED AT THE DEVICE BEING CONTROLLED UNLESS SHOWN OTHERWISE ON THE DRAWINGS OR MUTUAL AGREEMENT 15 MADE BETWEEN THE CONTRACTORS WITH CHANGE IN THE CONTRACT PRICE. WIRING FROM ALARM CONTACTS TO ALARM SYSTEM BY ED; ALL CONTROL FUNCTION WIRING BY MD. MD SHALL COORDINATE LOCATIONS WITH ED. CONNECTIONS TO ALL CONTROLS DIRECTLY ATTACHED TO DUCTS, PIPING, AND MECHANICAL EQUIPMENT SHALL BE MADE WITH FLEXIBLE CONNECTORS. WIRING: ALL LINE VOLTAGE WIRING AND INSTALLATION IN CONNECTION WITH THE AUTOMATIC CONTROL SYSTEM SHALL BE BY THE ELECTRICAL CONTRACTOR AND SUPERVISED BY THE MECHANICAL CONTRACTOR. THE MECHANICAL CONTRACTOR SHALL PROVIDE TO THE ELECTRICAL CONTRACTOR TWO (2) COPIES OF THE COMPLETE SUBMITTAL INCLUDING TERMINAL WIRING DIAGRAMS. UPON COMPLETION OF THE INSTALLATION, MECHANICAL CONTRACTOR SHALL LINK ALL VALVES AND DAMPERS AND SHALL CHECK OUT AND CALIBRATE CONTROLS FURNISHED UNDER THIS SECTION. WHEN HVAC UNIT(5) ARE EQUIPPED WITH ECONOMIZER OPTION, THE FOLLOWING SHALL APPLY: BELOW 55 DEG. F. OUTSIDE TEMPERATURE, AN OUTSIDE AIR CHANGEOVER THERMOSTAT WILL LOCK OUT THE COMPRESSOR AND MODULATE THE RETURN AIR AND OUTSIDE AIR DAMPERS TO SATISFY THE ROOM THERMOSTAT WHEN THE SELECTOR SWITCH 15 ON "COOL". WHEN THE OUTDOOR AIR TEMPERATURE 15 ABOVE 55 DEG. F., THE AIR CHANGEOVER THERMOSTAT SETTING THE DAMPERS SHALL MOVE TO A MINIMUM POSITION (10% OUTSIDE AIR). WHEN HEAT 15 ENERGIZED, THE OUTDOOR AIR DAMPER ALSO MOVES TO THE MINIMUM POSITION. THE OUTDOOR AIR DAMPER SHALL CLOSE WHENEVER THE INDOOR FAN 15 NOT OPERATING OR THE SELECTOR SWITCH 15 IN THE "OFF" POSITION. NOTE: ALL REFRIGERANT PIPING, RECHARGING, REPAIRS, ETC., FOR EXISTING AND NEW H.VA.C. EQUIPMENT SHALL BE DONE IN ACCORDANCE WITH GOVERNMENT MANDATED REFRIGERANT HANDLING REGULATIONS. 15712 ROOFTOP PACKAGED HVAC UNITS (EXISTING) A. CONTROLS: I. THE COOLING SYSTEM SHALL BE PROTECTED WITH HIGH PRESSURE THERMOSTATS, LOW PRESSURE THERMOSTATS, LOSS -OF -CHARGE PROTECTION, INDOOR COIL FREEZE THERMOSTATS, AND CURRENT AND TEMPERATURE SENSITIVE OVERLOAD DEVICES. 2. ALL DEVICES SHALL BE WIRED TO PREVENT COMPRESSOR RESTART UNTIL RESET OF CIRCUIT BREAKER. 3. THIS CONTRACTOR SHALL INSTALL HEATING/COOLING "T" THERMOSTAT(5) PER PLAN TO PROVIDE CONTROL OF STAGED COOLING AND STAGED HEATING WITH AUTOMATIC CHANGEOVER AND "FAN ON" CONTROL. MOUNT DEVICES AT 60" AFF TO BOTTOM PER ADA. PROVIDE INITIAL PROGRAMMING OF SYSTEM. COORDINATE PROGRAMMING REQUIREMENTS WITH TENANT NATIONAL ACCOUNT REPRESENTATIVE AND PROGRAMMING SECTION BELOW. 4. WHEN THERMOSTAT/SENSOR CALLS FOR COOLING, FIRST STAGE OF COMPRESSOR SHALL ENERGIZE UNTIL SPACE TEMPERATURE IS SATISFIED. AFTER TEN MINUTES, SECOND STAGE OF COMPRESSOR SHALL ENERGIZE UNTIL SPACE TEMPERATURE 15 SATISFIED. 5. WHEN THERMOSTAT/SENSOR GALLS FOR HEATING, FIRST STAGE OF HEAT SHALL ENERGIZE UNTIL SPACE TEMPERATURE 15 SATISFIED. AFTER TEN MINUTES, SECOND STAGE OF HEAT SHALL ENERGIZE UNTIL SPACE TEMPERATURE 15 SATISFIED. 6. FAN SHALL ENERGIZE AND RUN CONTINUOUSLY DURING OCCUPIED HOURS. 7. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT CONTROL ELEMENTS ARE CALIBRATED, ADJUSTED, AND IN PROPER WORKING CONDITION. B. PROGRAMMING OF CONTROLS/SEQUENCE OF OPERATION: I. CONTRACTOR SHALL PROVIDE PROGRAMMING OF HVAC CONTROL SYSTEM PER MANUFACTURER'S INSTRUCTIONS AND A5 REQUIRED TO MEET THE BELOW OPERATION. 2. SPACE TEMPERATURE SETPOINT - UNOCCUPIED SETPOINTS SHALL BE 75 DEG F COOLING AND 60 DEG F HEATING. WARM-UP/OCCUPIED SETPOINTS SHALL BE 72 DEG F COOLING AND 65 DEG F HEATING. SETPOINTS SHALL BE LOCKED OUT TO PREVENT ADJUSTMENT MORE THAN 3 DEG F UP OR DOWN FROM DEFAULT. 3. ALL SETPOINTS ARE ADJUSTABLE - PRIOR TO PROGRAMMING OF CONTROLS SYSTEM, VERIFY SETPOINTS WITH TENANT CONSTRUCTION REPRESENTATIVE. 4. UNIT OPERATION - DURING OCCUPIED HOURS, FAN SHALL RUN CONTINUOUSLY ("FAN ON'') AND UNIT SHALL STAGE COOLING OR HEATING. DURING UNOCCUPIED HOURS, FAN SHALL RUN ONLY WHEN HEATING OR COOLING ARE CALLED FOR ("FAN AUTO"). 5. O CUPIEDNNOCCUPIED/WARM-UP - UNOCCUPIED MODE SHALL BE SET FOR ONE HOUR AFTER MALL CLOSING TO ONE HOUR PRIOR TO MALL OPENING. UNOCCUPIED MODE SHALL HAVE MANUAL OVERRIDE. 6. REFER TO CONTROLS SECTION ABOVE FOR ADDITIONAL REQUIREMENTS. SMOKE DETECTORS (NFPA REQUIREMENTS): NO SMOKE DETECTOR DEVICES REQUIRED ON SYSTEMS 1111 CFM AND LESS. EACH SUPPLY SYSTEM SHALL BE EQUIPPED WITH A MANUAL EMERGENCY STOP CONTROL LOCATED AT A CONVENIENT AND ACCESSIBLE POINT FOR SHUTTING OFF THE FAN IN CASE OF FIRE. FOR THE PURPOSE OF THIS SPECIFICATION, THE DISC. SWITCH WILL SERVE THIS PURPOSE. IN SYSTEMS OVER 2,000 CFM CAPACITY, SMOKE DETECTORS APPROVED FOR DUCT INSTALLATION SHALL BE INSTALLED AT A SUITABLE LOCATION IN THE MAIN SUPPLY DUCT ON THE DOWN STREAM SIDE OF THE FILTERS, AND THE RETURN AIR STREAM (PRIOR TO EXHAUSTING FROM THE BUILDING OR BEING DILUTED BY OUTSIDE AIR) TO AUTOMATICALLY STOP THE FAN. EXCEPTION: BOTH DETECTORS MAY BE OMITTED, PROVIDED THAT THE SYSTEM 15 LESS THAN 15,000 CFM CAPACITY, THE ENTIRE SYSTEM 15 WITHIN THE SPACE SERVED, AND SUCH SPACE 15 PROTECTED BY AN AREA SMOKE DETECTOR SYSTEM. CONTRACTOR NOTE: SOME JURISDICTIONS REQUIRE PHOTOELECTRIC TYPE DETECTORS. CONTRACTOR SHALL VERIFY WITH LOCAL BUILDING OFFICIALS PRIOR TO START OF CONSTRUCTION AND PROVIDE IF REQUIRED. SMOKE DETECTORS SHALL BE IONIZATION TYPE DUCT DETECTORS FOR DETECTION OF COMBUSION GASES t FIRE 4 SMOKE IN AIR CONDITIONING AND VENTILATION SYSTEM DUCTS $ SHALL BE IN COMPLIANCE WITH THE NATIONAL FIRE PROTECTION ASSOCIATION, RECOMMENDED PRACTICES PAMPHLET #10A. THE ASSEMBLY SHALL CONSIST OF A CASTING TO ACCOMMODATE SAMPLING TUBES THAT EXTEND ACROSS THE DUCT OF THE VENTILATION SYSTEM. WHILE THE FANS ARE OPERATING, A CONTINUOUS CROSS SECTIONAL SAMPLING OF AIR FROM THE DUCT WILL FLOW THROUGH THE IONIZATION DETECTOR, AFTER WHICH TIME, SAMPLED AIR SHALL BE RETURNED TO THE DUCT. DETECTORS SHALL BE CAPABLE OF DETECTING THE PRODUCTS OF COMBUSTION OF 0.01 GRAMS PER CU. FT. OF AIR AT THE DETECTOR AND SHALL OPERATE ON THE IONIZATION PRINCIPLE. THE DETECTOR SHALL NOT CONTAIN HOT FILAMENT TUDE3 OR MOVING PARTS $ SHALL NOT REQUIRE REPLACEMENT OR READJUSTMENT Al -1 tR AN ALARM HAS DM/ GIVEN. THE DETECTOR SENSITIVITY SHALL BE INDIVIDUALLY ADJUSTABLE, FIXED, AND SET BY A FACTORY TRAINED TECHNICIAN AT INSTALLATION. IT SHALL BE POSSIBLE TO ACCURATELY MEASURE THE DETECTOR'S SENSITIVITY WITH AN APPROPRIATE INSTRUMENT. THE UNIT SHALL PROVIDE THE FOLLOWING FUNCTIONS: I. FURNISH NECESSARY POWER FOR OPERATION OF THE DETECTOR. 2. SUPERVISE THE DETECTOR CIRCUIT AND ALL RELAY COILS. 3. PROVIDE POWER TO THE NEON ALARM INDICATOR 4. PROVIDE ONE SET OF N.O. 4 ONE SET OF SPDT ALARM OPERATED RELAY CONTACTS. 5. PROVIDE ONE SET OF SPOT, TROUBLE -OPERATED RELAY CONTACTS. THE UNIT SHALL OPERATE FROM A TWO WIRE,120 VAC, 60 CYCLE POWER SOURCE AND SHALL BE OPERABLE OVER A RANGE OF 102-132 VAC. THE TROUBLE CIRCUIT SHALL ACTIVATE IF THE UNIT BECOMES INOPERATIVE DUE TO LOW INPUT VOLTAGE. THE STANDBY POWER CONSUMPTION, EXCLUDING ANY EXTERNAL DEVICES, SHALL NOT EXCEED I WATT. THE UNIT SHALL BE MOUNTED DIRECTLY TO THE OUTSIDE OF DUCT WITH BOLTS. A TEMPLATE SHALL BE PROVIDED FOR MAKING NECESSARY CUTOUTS AND HOLES. COMPLETE INSTRUCTIONS SHALL BE PROVIDED WITH THE UNIT. b4(3-40./bo MINIMUM O. A. REQUIREMENTS (per ASHRAE 62.1) REQUIRED: SALES AREA NON -SALES AREA 4113 s.f. x 0.3 cfm/s.f. ISO s.f. x 0.15 cfm/s.f. 1400 CFM OUTSIDE AIR TO BE PROVIDED THROUGH RTU -I$2. • 1234 cfm ▪ 147 cfm 1381 cfm . ROO OP HVAC UNIT SCHEDULE UNIT NO. MFR.,COOLING MODEWEIGHT NO. CFM OA. CFM EXT. S.P. DATA SUPPLY FAN MOTOR HEATING DATA FILTERS MGA MOCP (1-55)J REMARKS TOTAL COOLING MBH SENSIBLE COOLING MBH ARI EER it' BHP R.P.M. VOLTS PHASE CAPACITY INPUT MBH CAPACITY OUTPUT MBH RTU -I TRANE 0 1 3 3750 800 0.1" 120 qb -- Y -- 208 200 160 2" 41.6 60.0 -- ©© TITUS 500 RL (EX)RTU-2 CARRIER 4STJOOS 2800 600 0.6" 10 65 __ A -- 208 3 125 100 2" 44.1 50.0 -- O© A OI EXISTING ROOFTOP UNITS TO REMAIN AND BE REUSED. <> BALANCE SUPPLY, RETURN AND OUTSIDE AIR TO QUANTITIES SHOWN. VERIFY CONTROLS ARE IN GOOD WORKING ORDER 24V WIRING BY MECH. CONTR. FOR USE ON I6°0 DAMPER ONLY. T3I2 T -STAT DAMPER MOTOR 40VA., 24/I20V TRANSFORMER 120V WIRING BY ELECT. CONTR ZONE DAMPER DETAIL SCALE: NTS <> UNIT TO BE FURNICHCD AND INSTALLED BY LANDLORD. LANDLORD TO PROVIDE UNIT WITH FACTORY MOUNTED DISCONNECT, ECONOMIZER, BAROMETRIC RELIEF, AND FACTORY INSTALLED GFI DUPLEX RECEPTACLE. 4O 10.0 TONS WITH GAS HEAT. TITUS INDUSTRIES 1R DISTRIBUTION DEV1 SYMBOL CATALOG NUMBER SIZE MOUNTING MATERIAL FINISH PPR. BORDER STYLE MOD. NECK CEILING OTHER STEEL ALUM. 5D -I TTMS 24"x24" 12"4)A Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 B G 0 ft2 5D-2 TITUS 24"x24" 10'10 0 0 ft2 0 - A B G 5D-3 TITUS 500 RL 14"xl0" 12"xS" - DUCT MOUNTED 27631 - A A A 0 ft2 50-4 TITUSINALL 30o RL 14"x10" 12"xS" - MOUNTED Skylight Transmission A A A 0 ft2 RG -I TITUS3 24"x24" 22"x22" Door Loads 0 ft2 0 - A 0 G RG -2 T 5OF 24"xl2" 22"x10" - WALL MOUNTED 0 - A A 0 ft2 NOTES: I. SYMBOL KEY - FIRST LETTER: 5 -SUPPLY R -RETURN E -EXHAUST. SECOND LETTER: 0 -DIFFUSER R -REGISTER G -GRILLE. 2. CATALOG NUMBERS REFER TO TITUS AIR DEVICES. 3. PROVIDE DIRECTIONAL BLOW FOR AIRFLOW OTHER THAN 4 -WAY. 4. FINISH - "A" - CLE ARCHITECTURAL SHEETS FOR FINISH COLOR, IF NO COLOR SPECIFIED PROVIDE STANDARD WHITE. °B" - WHITE - G.C. TO FIELD PAINT. TO MATCH CEILING OR WALL WITH ENAMEL FINISH. 'G" - FLAT BLACK. 5. DAMPERS SHALL BE OPERABLE FROM FACE. "A" - OPPOSED BLADE RECT. MANUAL BALANCING DAMPER. "B" - ROUND MANUAL BALANCE DAMPER. "C" - FIRE DAMPER WITH VOLUME CONTROL. "D" - YOUNG'S REGULATOR, DAMPER MODEL # 5020 -CC. b. BORDER STYLE - "A" - SURFACE MOUNTED "B" - LAY -IN, PROVIDE WITH PLASTER FRAME FOR DRYWALL CEILING MOUNTING, SEE DETAIL ON SHEET M2. "C" - LAY -IN FRAME FOR T -BAR CEILING. 7. PROVIDE BOOT FOR DUCT MOUNTING. S A l REQUIRED MANDATORY MECHANICAL GAL ENERGY GODS REQU I REMENTS CCC M SERIES SHEET FOR EQUIPMENT EFFICIENCIES, SYSTEM CONTROLS, OUTDOOR -AIR VENTILATION RATES. HEATING AND COOLING LOADS: DESIGN HEATING AND COOLING LOADS, FOR TENANT SPACE, CALCULATED A5 REQUIRED. SYSTEM CONTROLS: EACH HEATING OR COOLING SYSTEM SERVING A SINGLE ZONE - A SPACE OR GROUP OF SPACES WITHIN A BUILDING WITH ANY COMBINATION OF HEATING, COOLING, OR LIGHTING REQUIREMENTS SUFFICIENTLY SIMILAR 50 THAT DESIRED CONDITIONS CAN BE MAINTAINED THROUGHOUT BY A SINGLE CONTROLLING DEVICE MUST HAVE ITS OWN TEMPERATURE CONTROL DEVICE. • THERMOSTATS CONTROLLING BOTH HEATING AND COOLING MUST EITHER BE A SOLID-STATE AN AUTOMATIC CONTROL DEVICE RESPONSIVE TO TEMPERATURE OR CAPABLE OF A 5 DEG. F DEADBAND, OR RANGE OF TEMPERATURE WHERE NO HEATING OR COOLING IS AVAILABLE. EXCEPTION: • DEADBAND CAPABILITY 15 NOT REQUIRED IF THE THERMOSTAT REQUIRES MANUAL CHANGEOVER BETWEEN HEATING AND COOLING AND DOES NOT HAVE AUTOMATIC CHANGEOVER CAPABILITY. • THE SYSTEM OR ZONE CONTROL MUST BE A PROGRAMMABLE THERMOSTAT OR OTHER AUTOMATIC CONTROL MEETING THE FOLLOWING CRITERIA: • CAPABLE OF AUTOMATICALLY SETTING BACK OR SHUTTING DOWN SYSTEMS DURING UNOCCUPIED HOURS FOR SEVEN DIFFERENT DAY SCHEDULES. • HAVE AN ACCESSIBLE 2 -HOUR OCCUPANT OVERRIDE • HAVE A BATTERY BACK-UP CAPABLE OF MAINTAINING PROGRAMMED SETTINGS FOR AT LEAST 10 HOURS IF POWER 15 LOST. OUTDOOR -AIR VENTILATION - SEE CALCULATIONS ON THIS C{ 'CET • THE SYSTEM MUST SUPPLY OUTSIDE VENTILATION AIR A5 REQUIRED BY CHAPTER 4 OF THE INTERNATIONAL MECHANICAL CODE. IF THE VENTILATION SYSTEM IS DESIGNED TO SUPPLY OUTDOOR AIR QUANTITIES EXCEEDING MINIMUM REQUIRED LEVELS, THE SYSTEM MUST BE CAPABLE OF REDUCING OUTDOOR -AIR FLOW TO THE MINIMUM REQUIRED LEVELS. • OUTDOOR -AIR SUPPLY SYSTEMS WITH DESIGN AIR FLOW RATES GREATER THAN 3,000 CUBIC MET PER MINUTE OF OUTDOOR AIR AND ALL EXHAUST SYSTEMS MUST HAVE DAMPERS THAT AUTOMATICALLY CLOSE WHILE THE EQUIPMENT IS NOT OPERATING. DUCT CONSTRUCTION AND INSULATION • DUCTWORK MUST BE CONSTRUCTED AND ERECTED IN ACCORDANCE WITH THE INTERNATIONAL MECHANICAL CODE. • SUPPLY AND RETURN AIR DUCTS FOR CONDITIONED AIR LOCATED IN UNCONDITIONED SPACES (SPACES NEITHER HEATED NOR COOLED) MUST BE INSULATED WITH A MINIMUM OF R-5. UNCONDITIONED SPACES INCLUDE ATTICS, GRAN/L. SPACES, UNHEATED BASEMENTS AND UNHEATED GARAGES. • SUPPLY AND RETURN AIR DUCTS AND PLENUMS MUST BE INSULATED TO A MINIMUM OF R -S WHEN LOCATED OUTSIDE THE BUILDING ENVELOPE THE ELEMENTS OF .A BUILDING THAT ENCLOSE CONDITIONED SPACES THROUGH WHICH THERMAL ENERGY MAY BE TRANSFERRED TO OR FROM THE EXTERIOR OR TO OR FROM UNCONDITIONED SPACES. • WHEN DUCTS ARE LOCATED IN EXTERIOR COMPONENTS (E.G., FLOORS OR ROOFS), MINIMUM R-5 INSULATION 15 REQUIRED ONLY BETWEEN THE DUCT AND THE BUILDING EXTERIOR. • ALL JOINTS, LONGITUDINAL AND TRANSVERSE SEAMS AND CONNECTIONS IN DUCTWORK MUST BE SECURELY SEALED USING WELDS, MECHANICAL FASTENERS WITH SEALS OR GASKETS OR MASTICS, MESH AND MASTIC SEALING SYSTEMS OR TAPES. TAPES AND MASTICS MUST BE LISTED AND LABELED IN ACCORDANCE WITH UL ISIA - A TEST PROCEDURE FOR TAPES AND MASTICS USED TO SEAL DUCTWORK OR UL ISIS - A TEST PROCEDURE FOR TAPES AND MASTICS USED TO SEAL DUCTWORK. EXCEPTION: • CONTINUOUSLY WELDED AND LOCKING -TYPE LONGITUDINAL JOINTS AND SEAMS ON DUCTS OPERATING AT STATIC PRESSURES LESS THAN 2 IN. W.G. PRESSURE CLASSIFICATION. • DUCTS MUST BE CONNECTED TO FANS AND OTHER AIR DISTRIBUTION EQUIPMENT INCLUDING MULTI -ZONE TERMINAL UNITS USING MECHANICAL FASTENERS WITH SEALS, MASTICS OR GASKETS. • EACH SUPPLY AIR OUTLET OR DIFFUSER AND EACH ZONE TERMINAL DEVICE (SUCH AS VAV OR MIXING BOXES) MUST HAVE ITS OWN BALANCING DEVICE. ACCEPTABLE BALANCING DEVICES INCLUDE ADJUSTABLE DAMPERS LOCATED WITHIN THE DUCTWORK, TERMINAL DEVICES OR SUPPLY AIR DIFFUSER • ALL DUCTS AND PLENUMS OPERATING AT STATIC PRESSURES GREATER THAN 2 IN. W.G. MUST BE SEALED. MATERIALS AND EQUIPMENT INFORMATION • OPERATION AND MAINTENANCE DOCUMENTATION MUST BE PROVIDED TO THE OWNER THAT INCLUDES AT LEAST THE FOLLOWING INFORMATION: • EQUIPMENT INPUT AND OUTPUT CAPACITY AND REQUIRED MAINTENANCE ACTIONS. • EQUIPMENT OPERATION AND MAINTENANCE MANUALS. • HVAC SYSTEM CONTROL MAINTENANCE AND CALIBRATION INFORMATION, INCLUDING WIRING DIAGRAMS, SCHEMATICS, AND CONTROL SEQUENCE DESCRIPTIONS. DESIRED OR FIELD DETERMINED SET POINTS MUST BE PERMANENTLY RECORDED ON CONTROL DRAWINGS, AT CONTROL DEVICES, OR, FOR DIGITAL CONTROL SYSTEMS, IN PROGRAMMING COMMENTS. • A COMPLETE NARRATIVE OF HOW EACH SYSTEM 15 INTENDED TO OPERATE. I- W o C(C) 2(?) WW D Z M (1). OCA ore I - w W " 1 J co O r r r CO (r) 0 W Z (0 W Z co ce W W Z Z Q Ex W Wvm Z Z W O�LLI Lt) U) U) u7 U) CD LL E O U C) 0 2 J✓ V) O W F O Ir"' W Z co MEMI WUME 0� Z00 W ›. W O) WW 1Lf VO-1 ES 0 O co W N Cl) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC / MD -SS / CJ APPROVED BY : XX REVISIONS: MECH SPEC'S SHEET M-2 OF 22 SHEETS DESIGN City Name Seattle IAP Location Washington Latitude 47.5 Deg. Longitude 122.3 Deg. Elevation 449.0 ft Summer Design Dry -Bulb 85.0 °F Summer Coincident Wet -Bulb 65.0 °F Summer Daily Range 18.3 °F Winter Design Dry -Bulb 23.0 °F Winter Design Wet -Bulb 19.2 °F Atmospheric Clearness Number 1.05 Average Ground Reflectance 0.20 Soil Conductivity 0.800 BTU/(hr-ft-°F) Local Time Zone (GMT +1- N hours) 8.0 hours Consider Daylight Savings Time No Simulation Weather Data noneN/A Current Data is 2001 ASHRAE Handbook RECEIVED Design Cooling Months January to December CITY OF TUKWILA HVAC LOAD CALCULATIONS AUG 1 2 2013 PERMIT CENTER DESIGN COOLING DESIGN HEATING COOLING DATA AT Jun 1600 COOLING OA DB / WB 84.0°F! 65.0°F HEATING DATA AT DES HTG HEATING OA DB / WB 23.0°F/19.2°F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) • Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft2 0 - 0 ft2 - - Wall Transmission 0 ft2 0 - 0 ft2 0 - Roof Transmission 5093 ft2 9328 - 5093 ft2 27631 - Window Transmission 0 ft2 0 - 0 ft2 0 - Skylight Transmission 0 ft2 0 - 0 ft2 0 - Door Loads 0 ft2 0 - 0 ft2 0 - Floor Transmission 0 ft2 0 - 0 ft2 0 - Partitions 0 ft2 0 - 0 ft2 0 - Ceiling 0 ft2 0 - 0 ft2 0 - Overhead Lighting 5413 W 11437 - 0 0 - Task Lighting 3072 W 9004 - 0 0 - Electric Equipment • 6040 W 19312 - 0 0 - People 142 28804 29429 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 10% / 10% 7789 2943 10% 2763 0 » Total Zone Loads - 86674 32371 - 30394 0 Zone Conditioning - 101082 32371 - 33929 0 Plenum Wall Load 30% 0 - 0 0 - Plenum Roof Load 70% 21764 - 0 0 - Plenum Lighting Load 30% 5541 - 0 0 - Return Fan Load 6532 CFM 0 - 6532 GEM 0 - Ventilation Load 1381 CFM 10586 -5823 1381 CFM 66300 0 Supply Fan Load 6532 CFM 12722 - 6532 CFM -12722 - Space Fan Coil Fans - 0 - - 0 - Duct Heat Gain / Loss 5% 4284 - 5% 1520 - » Total System Loads - 165979 26648 - 89027 0 Central Cooling Coil - 155979 26551 - 0 0 Central Heating Coil - 0 - - 89027 - » Total Conditioning - 166979 26551 - 89027 0 - -� 4 T Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads °.®.....}-t . - a I- W o C(C) 2(?) WW D Z M (1). OCA ore I - w W " 1 J co O r r r CO (r) 0 W Z (0 W Z co ce W W Z Z Q Ex W Wvm Z Z W O�LLI Lt) U) U) u7 U) CD LL E O U C) 0 2 J✓ V) O W F O Ir"' W Z co MEMI WUME 0� Z00 W ›. W O) WW 1Lf VO-1 ES 0 O co W N Cl) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC / MD -SS / CJ APPROVED BY : XX REVISIONS: MECH SPEC'S SHEET M-2 OF 22 SHEETS LIGI-IT GAGE FRAMING — CROSS REFERENCE GUIDE MIL. TI-IICKNESS - GAGE NUMBER CROSS REFERENCE 25 GA. 18 MIL 22 GA. 27 MIL 16 GA. 54 MIL 20 GA. 33 MIL 14 GA. 68 MIL 18 GA. 43 MIL 12 GA. 97 MIL EXAMPLE CROSS REFERENCE: 3 5/8", 18 GA STRUCTURAL METAL STUDi=S1D) STUD DEPTH =3.625" =3 5/8" 62S 162- 3 METAL STUD / FLANGE UD (T=TRACK) WIDTH THICKNESS =1.625" =43 MIL (18 GA.) =1 5/8" TYPICAL STRUCTURAL STUDS AND TRACKS FORMER STANDARD DESIGNATION NEN SSMA DESIGNATION (STEEL STUD MANUFACTURERS ASSOCIATION) 2 1/2", 20 GA. STUD w/ 1 5/8" FLANGE 2 1/2", 18 GA. STUD w/ 1 5/8" FLANGE 2505162-33 2505162-43 3 5/8", 20 GA. STUD w/ 1 5/8" FLANGE 3 5/8", 18 GA. STUD w/ 1 5/8" FLANGE 3625162-33 3625162-43 6", 20 GA. STUD w/ 1 5/8" FLANGE 6", 18 GA. STUD w/ 1 5/8° FLANGE 6005162-33 6005162-43 8", 18 GA. STUD w/ 1 5/8" FLANGE 8", 16 GA. STUD w/ 1 5/8" FLANGE 8009162-43 8009162-54 10", 18 GA. STUD w/ 15/8" FLANGE 10', 16 GA. STUD w/ 15/8" FLANGE 10009162-43 10005162-54 12", 16 GA. STUD w/ 1 5/8" FLANGE 12", 12 GA. STUD w/ 1 5/8" FLANGE 12005162-54 12005162-97 1 5/8", 22 GA. TRACK w/ 1 1/4" LEG 1 5/8", 20 GA. TRACK w/ 1 1/4" LEG 162T125-27 162T125-33 2 1/2", 20 GA. TRACK w/ 1 1/4" LEG 2 1/2", 20 GA. TRACK w/ 2" LEG 2 1/2", 18 GA. TRACK w/ 1 1/4" LEG 2 1/2", 18 GA. TRACK w/ 2" LEG 250T125-33 250T200-33 250T125-43 250T200-43 3 5/8", 20 GA. TRACK w/ 1 1/4" LEG 3 5/8", 20 GA. TRACK w/ 2" LEG 3 5/8", 18 GA. TRACK w/ 1 1/4" LEG 3 5/8", 18 GA. TRACK w/ 2" LEG 3627125-33 362T200-33 362T125-43 362T200-43 6", 20 GA. TRACK w/ 1 1/4" LEG 6", 20 GA. TRACK w/ 2" LEG 6", 18 GA. TRACK w/ 1 1/4" LEG 6", 18 GA. TRACK w/ 2" LEG 600T125-33 6007200-33 600TI25-43 600T200-43 TYPICAL 1IAT (FURRING) CI-IANNELS 7/8", 25 GA. FURRING CHANNEL 7/8", 22 GA. FURRING CHANNEL 087F125-18 087F125-27 LIGHT GAGE FRAMING SCREW CONNECTIONS UNLESS NOTED, LIGHT GAGE FRAMING CONNECTIONS SHALL BE MADE USING #8 SCREWS. SEE DETAIL A/S03.1 FOR DIAGONAL BRACING CONNECTIONS. AT LOCATIONS WHERE SHEATHING MATERIAL IS PLACED AGAINST THE SCREW HEADS OF LIGHTGAGE METAL FRAMING CONNECTIONS, PANCAKE HEAD SCREWS SHALL BE USED 50 THAT THE SHEATHING MATERIAL REMAINS STRAIGHT AND SMOOTH. #8 SCREWS, TYP 6" M.1 5-1 • -4- 4 VERTICAL WALL STUD • • 7 -TOP TRACK SPLICE (CENTERED BETWEEN VERT STUDS) VWALLERTICAL STUD #8 SCREWS, TYP • • -t- J a_ _ _ METAL STUD x 1'-0" (GAGE TO MATCH GAGE OF TRACK) M.1 SECTION - J TOP TRACK METAL STUD x 1'-0" TOP TRACK SPLICE N.T.S. 42DSO11MODETL M CODED NOTES: 0 DBL 6" DP, 20 GA BEAM WITH 3 5/8", 20 GA TRACK TOP 4 BOTTOM O DBL 8" DP, 16 GA BEAM WITH 3 5/8", 16 GA TRACK TOP 4 BOTTOM 0 BUILT-UP BOX COLUMN - DBL 3 5/8" DP, 20 GA STUDS WITH 3 5/8", 20 GA TRACK, EA SIDE (SEE G/S-3). ATTACH BEAM TO BOX COLUMN PER DETAIL G/S-3, UNLESS NOTED. S/LTT20 HOLD DOWN TENSION TIE BY SIMPSON STRONG -TIE COMPANY *8 SCREW @ 12"c/c #8 SCREW @ 12"c/c #8 SCREW @ 12"c/c STRUCTURAL NOTES: A. CONTROLLING BUILDING CODE: 2009 INTERNATIONAL BUILDING CODE SEISMIC DESIGN CATEGORY 'D' SEISMIC DATA: SDs = 0.969 B. LIGHT GAGE FRAMING I. COLD FORMED STEEL FRAMING SHALL CONFORM TO REQUIREMENTS OF THE LATEST EDITION OF AISI "SPECIFICATION FOR DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 2. ALL MEMBERS SHALL BE FORMED FROM CORROSION -RESISTANT STEEL (GRADE 33 UNLESS OTHERWISE SPECIFIED) AND THEN ZINC COATED PER ASTM A653-94, GRADE G-60. 3. ALL COLD FORMED MEMBERS SHALL COME FROM A SINGLE MANUFACTURER, "CLARK" OR EQUAL. THE INSTALLATION SHALL COMPLY WITH THE MANUFACTURER'S RECOMMENDATIONS. UNLESS NOTED, WALL TRACK GAGE SHALL EQUAL WALL STUD GAGE. DEEP LEG TRACK WITH 2" FLANGE WIDTH SHALL BE USED WHERE NOTED ON DRAWINGS. SEE DETAIL R/S-1 FOR LIGHT GAGE METAL FRAMING DESIGNATIONS. 6. BASE TRACKS SHALL BE SET ON SMOOTH AND LEVEL CONCRETE OR NON -SHRINK GROUT SUCH AS "MASTERFLOW 713" BY MASTER BUILDERS. 7. FASTENING OF COMPONENTS SHALL BE WITH SELF -DRILLING CADMIUM PLATED OR ZINC COATED SCREWS (UNLESS NOTED). SCREWS SHALL BE OF SUFFICIENT SIZE TO ENSURE THE STRENGTH OF THE CONNECTION. SEE DETAIL R/S-1 FOR ADDITIONAL SCREW REQUIREMENTS. 8. SPLICES IN FRAMING COMPONENTS OTHER THAN BOTTOM WALL TRACK ARE NOT PERMITTED. 9. STUDS SHALL BE INSTALLED 50 THE ENDS ARE POSITIONED AGAINST THE INSIDE OF THE RUNNER TRACK WEB PRIOR TO FASTENING AND SHALL BE ATTACHED TO BOTH FLANGES OF THE UPPER AND LOWER RUNNER TRACKS, WITH (1)-#8 SCREW IN EACH FLANGE OF EACH STUD, UNLESS NOTED. LIGHT GAGE METAL FRAMING RIM OM R CODED NOTES MOD STRUCTURAL SPECIFICATIONS c STOREFRONT FRAMING O U U Q B"-).4 €DL FEVIEW D FOR CODE COMPLIANCE APPROVED SEP 052013 City of Tukwila BUILDING DIVISION I J 4 i RECEIVED CITY OF TUKWILA AUG 1 Z 2013 PERMIT CENTER NOT USED NONE N LOCATION PLAN N.T.S. A F- W (V W LO Oo W W Z ZM co (I) = N W Dob OP.,C1 A35013-0075 oW F O N W z m JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: STRUCTURAL SPECIFICATIONS & NOTES SHEET S-1 OF 22 SHEETS NOT USED 3 5/8" DIAG BRACE. SEE DETAIL A/S-3 JIM11:11:1=1:1[I 3 5/8", 20 GA DIAGONAL. ALL DIAGS TO ALIGN. METAL SCREWS, TYP. (SEE DETAIL R/S0I.1 FOR SCREW SIZE) 11 11 11 111 rn 3 5/8", 20 GA. (MIN) @ 16" c/c. TYP UNLESS NOTED NOTE: SEE DRAWING S-1 FOR CODED NOTES • 0.157" DIA POWDER ACTUATED FASTENERS (1-1ILTI X -U OR EQUIVALENT) @ 12" 0.C., TYP 3 5/8" DIAG BRACE. SEE DETAIL A/5-3 Iiii111:1=71.111 3 5/8", 20 GA DIAGONAL. ALL DIAGS TO ALIGN. NOTE: SEE DRAWING S-1 FOR CODED NOTES METAL SCREWS, TYP. (SEE DETAIL R/501.1 FOR SCREW SIZE) 3 5/8", 20 GA. (MIN) @ 16" c/c. TYP UNLESS NOTED 3 5/8" DIAG BRACE. SEE DETAIL A/5-3 _DID [I I I TTMTIIVIllll1J_ILIIIIIII NOTE: SEE DRAWING 5-1 FOR CODED NOTES METAL SCREWS, TYP. (SEE DETAIL R/501.1 FOR SCREW SIZE) 3 5/8", 20 GA. (MIN) @ 16" c/c. TYP UNLESS NOTED STOREFRONT SECTION • = 1 0" H STOREFRONT SECTION = 11'"0" 2x2x 12 GA x 01-8" LONG FRAMING CLIP EACI-I SIDE w/(3)--#12 SCREWS EACH LEG, TYP NOTE: SEE DRAWING 5-1 FOR CODED NOTES NOT USED R STOREFRONT SECTION = 1-O" L NOT USED BEAM CONNECTION N.T.S. NOT USED P NOT USED K NOT USED F NOT USED ••• NOTE: SEE DRAWING S -I FOR CODED NOTES REVIEWED FOR CODE COMPLIANCE APPROVED SEP 05 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 1 2 2013 PERMIT CENTER NOT USED STOREFRONT FRAMING PLAN 1/2"=l' -O" MOO u) 14) UJ FO CN z —J co 2 i— z co LU LLJ < I— > W&DUJ CN u) 0 0,6 L.L1 D < JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC / MD -SS / CJ APPROVED BY : XX REVISIONS: STOREFRONT FRAMING PLAN & SECTIONS SHEET S-2 22 SHEETS _____ . -.......4„. ..;;;I=P= 5/8"42L. A°GADIALLN. 3DIAAWA GS TO - / -,, \ NOTE: SEE DRAWING 5-1 FOR CODED NOTES METAL SCREWS, TYP. (SEE DETAIL R/501.1 FOR SCREW SIZE) 3 5/8", 20 GA. (MIN) @ 16" c/c. TYP UNLESS NOTED STOREFRONT SECTION • = 1 0" H STOREFRONT SECTION = 11'"0" 2x2x 12 GA x 01-8" LONG FRAMING CLIP EACI-I SIDE w/(3)--#12 SCREWS EACH LEG, TYP NOTE: SEE DRAWING 5-1 FOR CODED NOTES NOT USED R STOREFRONT SECTION = 1-O" L NOT USED BEAM CONNECTION N.T.S. NOT USED P NOT USED K NOT USED F NOT USED ••• NOTE: SEE DRAWING S -I FOR CODED NOTES REVIEWED FOR CODE COMPLIANCE APPROVED SEP 05 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA AUG 1 2 2013 PERMIT CENTER NOT USED STOREFRONT FRAMING PLAN 1/2"=l' -O" MOO u) 14) UJ FO CN z —J co 2 i— z co LU LLJ < I— > W&DUJ CN u) 0 0,6 L.L1 D < JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC / MD -SS / CJ APPROVED BY : XX REVISIONS: STOREFRONT FRAMING PLAN & SECTIONS SHEET S-2 22 SHEETS / , NOTE: SEE STOREFRONT FRAMING PLAN A/S-2 FOR LOCATIONS WHERE BEAM IS CONTINUOUS ACROSS TOP OF COLUMN 411111-___________ wzr Air / ARIA CONNECTION j AT NOTE: SEE CODED NOTES ,,----?1REQUIRING BEAMS WEB STIFFENERS AT BEARING POINTS EXIST JOIST CHORD OR EXIST SEAM BEAM FLG B ATTACH o1 TO EXIST STL EXIST 14/(3) -#12 -SCREWS CONC MTL DECK OR COMP ,'- SLAB 7 I / ATTACH W/()-#12 Ol TO EXIST STL SCREWS I L SEE $ SECTIONS BUILT-UP BEAM 18 GA. PLAN F. - BOX PLATE �- r--------__, V -#. , _ Ar, ,#' . _ -,. ,) ,-- 18 GA (TRACK MATCH TOP TRACK DEPTH SHALL STUD DEPTH) L 6�� Thi,L <- f DIAD BRACE / / / / / /0 / _11 MAX / 1 / ® ®----- EXIST CHORD _ FLG JOIST OR BEAM o LT 5 VIEW A - A DIAG BRACE VIEW 5-5 EACH SIDE WITH (8)-#8 PAN HEAD SCREWS, 3 5/8" OR 6" DEEP STUDS AS REQUIRED BY OTHER SECTIONS AND DETAILS �` LIGI4TGAGE BOX BEAM TO � .* `/ STOP FULLLENGTH TRACKS COOLUMNLUM TRACK 3 5/8" OR AS REQUIRED SECTIONS OF BUILT-UP SNORT OF TOP 6" DEEP TRACK BY OTHER AND DETAILS EXIST BAR JOISTS ORSPACING STEEL BEAMS @ 61-0" CONTACT STRUCTURAL ENGINEER FOR REVISED DETAILS IF JOIST OR BEAM EXCEEDS 6'-0". #12 SCREWS (TYP) O.C. MAX G 12 —ice_ _.� }l'-- (2) 2x2x0'-3", GA FRAMING CLIPS A 1 IIIA ����- *12 SCREWS, TYP ��IiijI �` \ \�`. A` 1 .`.� DIAGONAL BRACING /( SEE 1— V EW 8-5 FOR DIAGONAL BRACING VI EN C -G DIAGONAL PARALLEL TO EXIST BAR JOISTS OR /— CONNECTION EXISTING STEEL BEAMS PARTIAL PLAN VIEW JOIST COLUMN CONNECTION (TVP, ` DIAGONALS PARALLEL TO UNLESS NOTED) 18 GA BASE TRACK (TRACK DEPTH SHALL MATCH STUD DEPTH). 4 � 1111. STOP FULL BUILT-UP TRACK (2)-#8 PAN SCREWS LENGTH TRACKS OF COLUMN SHORT OF BASE HEAD EACH SIDE EXIST BAR JOISTS OR STEEL BEAMS G CODED NOTES: \ DIAGONAL BRACING ATTACHMENT TO EXISTING Q 6", 16 GA MTL STUD WITH 6", 16 GA DEEP LEG" STRUCTURE DIAGONAL PERPENDICULAR TO JOIST TRACK. /['I 2 SCREWS @ 6" 2" FROM EACH END 02 2 x 2 x 12 GA x 6" LG FRAMING CLIP, ONE SIDE OF DIAG, 14/(3)-#12 SCREWS EACH LEG. DIAGONAL BRACING ATTACHMENT N O.G. MAX AND TO EXISTING BAR JOISTS OR STEEL BEAMS LIGHTGAGE BOX COLUMN BASE CONNECTION (TVP, UNLESS NOTED) (4)-3/16" DIA CONCRETE SCREWS TYPICAL DIAGONAL BRACE CONNECTION LIGHTGAGE BOX COLUMN DETAIL 3"=1'-°�� G NOT USED C :: OODS031COOCOLM O3IEOO OODS031EOOBRAC 2"x2"x0'-6" LG, 12 GA FRAMING CLIP W/(3)-#8 SCREWS EA LEG CONTINUOUS TRACK MTL STUD FRAMING, TYP. SEE I/2„ NOTE: BRIDGING IS NOT REQUIRED IF SHEATHING IS ATTACHED TO BOTH FACES OF THE STUD. (SHEATHING WALL LEGEND ON ARCH 2" x 2" x 16 GA CHANNEL LESS THAN STUD WIDTH, EVERY STUD WITH (4) DRAWINGS CLIP ANGLE 1/4" TVP #8 SCREWS .41,/ /• INCLUDES, BUT IS NOT LIMITED TO, GYPSOM BOARD, PLYWOOD, CEMENT BOARD, ETC.) CENTER DIAGONAL OVER VERTICAL STUD ' (GAGE TO MATCH WALL STUD, EXCEPT USE 20 GAGE MIN ATTACH TRACK TO WALL STUD w/(2) -#s SCREWS EACH SIDE. WALLS WI-IERE DIAGONAL I S AT LOCATIONS WHERE STUD SPACING IS TIGHT, INSTALLATION OF ANGLES AFTER STUDS ARE ATTACH ANGLES TO INSTALLING STUDS. VERTICAL (MAKING DIFFICULT IN PLACE), STUDS BEFORE iX• *II - ' moi'' i i 'ATTACI-IED - - 1,--i TO TOP OF WALL CONNECT TO EXISTINt STRUCTURE PER DETAIL L/S-3 l '9! NOTE: FOR DOUBLE STUD \\I:40o DIAGONALS, "SECOND" STUD SHALL * END AS CLOSE AS POSSIBLE TO END CONNECTION, TOP 4 BOTTOM. * CONTINUOUS TRACK (GAGE TO ` MATCH WALL STUD, EXCEPT MIN 11/2" WIDEx1/2"DPx16GA COLD -ROLLED CHANNEL AT 5'-0" O.C. MAX - LOCATE VERTICALLY ":T.s. F BRIDGING DETAIL OODSO31ROODETL REVIEWED FOR CODE COMPLIANCE VIEWS A -A `+ USE 20 GAGE TRACK) 18 GA VERTICAL SLOTTED SLIP -TRACK 18 GA VERTICAL SLOTTED SLIP -TRACK APPROVED SEP 0 5 2013 City of Tukwila BUILDING DIVISION � , ` (6)-#8 SCREWS I I CONNECT TRACK TO VERT STUDS W/(1)-#8 SCREW IN EACH FLANGE OF EACH STUD, EXCEPT INSTALL (2)-48 SCREWS- IN EACH FLANGE AT VERT STUDS WITH DIAGONALS WALL OR "SLP -TRK" BY (DEPTH TO ATTACH TO PAF OR (2) 3/4" MATCH STRUCTURE #12 DIETRICH VERTICAL SCREWS SYSTEMS, W/ AT INC. "SLP -TRK" STUD DEPTH) (DEPTH TO (2) 0.205" DIA. ATTACH TO 16" 0.C. PAF OR (2) 3/4" 3/4" BY MATCH STRUCTURE #12 DIETRICH VERTICAL SCREWS SYSTEMS, W/ AT INC. STUD DEPTH) (2) 0.205" DIA. 16" 0.C. 3/4" STOREFRONT STUD. DIAGONAL BRACING OPTIONS 20 GA. DIAGONAL BRACE OPTIONS: LENGTH- DIAGONAL LENGTH - MAX i r i i MAX MAX MAX I - I 1111111DIAGONAL UP TO 10'-0" 10'-1" TO I5'-0" AC 1 SINGLE 3 5/8", DBL 3 5/8", 20 GA. STUDS WITH 1 20 GA. DIAGOAL 5/8" WIDE FLANGES 1 5/8"� 1 'S/8" 1" DEFL. GAP I" DEFL. GAP SEE SCHEDULES FOR FINISHSIZES ES AND STUD INSTALL SLIP TRACK AND FIRE-SAFING MATERIALS ( #8 SCREWS @ #8 WAFERHEAD SCREW PER MANUFACTURER'S RECOMMENDATIONS TOACHIEVE 12"c/c VIEW A A VIEW $-B (1) IN EACH FLANGE OF EACH VERT STUD. INSTALL PER ONE HOUR FIRE RATING SPACING OF DIAGONAL BRACING *CONTACT STRUCTURAL ENGINEER FOR LENGTHS INTERIOR PARTITIONS - 46" O.C. MAX STOREFRONT FRAMING - 48" O.C. MAX LONGER THAN 18'-0". C V C i MANUFACTURERS 7 (NON -RATED) RECOMMENDATIONS (ONE HOUR FIRE -RATED) NOTE: CONSTRUCT WALL PER UL ASSEMBLY REQUIREMENTS SHOWN ON ARCHITECTURAL RCC f f� CITY OF TUKWILA DRAWINGS. Boor(9,0 40)....0 AUG 1 12013 PERMIT CENTER SEISMIC DESIGN CATEGORIES D, E & F NOT USED J DEFLECTION TRACK 3""1L01 E TYPICAL DIAGONAL BRACING 1""1'-°�� A OODS031A11BRAC OODS031L01DETL I— W CV W0 2L0 (1) U) I— (J) c Q r\OUJO 0_Z' Z CO I (/)00 =N WPI` J d0 � A35013-0075 �L-1(c J1 cwC) wocti< Z H w D Lir Q O es, w (n CV (/) JOB NO. 2170 DATE: 08-06-13 STORE TEAM: MC/MD-SS/CJ APPROVED BY : XX REVISIONS: STRUCTURAL CONSTRUCTION DETAILS SHEET S-3 OF 22 SHEETS