Loading...
HomeMy WebLinkAboutPermit D13-286 - PACIFIC RIM - TENANT IMPROVEMENTPACIFIC RIM 6000 SOUTHCENTER BL D13-286 City of110ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 3597000220 Address: 6000 SOUTHCENTER BL TUKW Suite No: Project Name: PACIFIC RIM 111 DEVELOPMENT PERMIT Permit Number: D13-286 Issue Date: 09/05/2013 Permit Expires On: 03/04/2014 Owner: Name: PACIFIC RIM HOLDINGS L L C Address: 6000 SOUTHCENTER BLVD #70 , TUKWILA WA 98188 Contact Person: Name: ROB VAN HOUTEN Address: 6000 SOUTHCENTER BL , TUKWILA WA 98188 Contractor: Name: POWELL RENOVATIONS LLC Address: 22211 MARINE VIEW DRS , SEATTLE WA 98198 Contractor License No: POWELRL939PE Lender: Name: Address: Phone: Phone: 206 824-8001 Expiration Date: 10/05/2013 DESCRIPTION OF WORK: DEMOLITION OF EXISTING ROTTED DECK LAYER, REPAIR ROTTED STRUCTURE IN LIKE KIND, ADD NEW DECKING (3/4 TNG CDX + 1/2" ACX). NEW WEATHERPROOF URETHANE DECK COATING. Value of Construction: $30,000.00 Fees Collected: $681.40 Type of Fire Protection: International Building Code Edition: 2012 Type of Construction: Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-286 Printed: 09-05-2013 • Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. Start Time: End Time: Fill 0 c.y. End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: N 1 f Permit Center Authorized Signature: Date: I hereby certify that I have read and xam ned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie wit whether specified herein or not. The granting of this permit does not pr construction or the performance of wor I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. me to give authority to violate or cancel the provisions of any other state or local laws regulating Signature: Print Name: ;-2-g Se.c.� Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: The special inspection of bolts to be installed in concrete prior to and during placement of concrete. 5: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke -developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 6: All construction shall be done in conformance with the approved plans and the requirements of the International dm: IBC -7/10 D13-286 Printed: 09-05-2013 Building Code or International Residential Cod110ternational Mechanical Code, Washington SillEnergy Code. 7: Structrual Observations in accordance with I.B.C. Section 1709 is required. At the conclusion of the work included in the permit, the structural observer shall submit to the Building Official a written statement that the site visits have been made and identify any reported deficiencies which, to the best of the structural observer's knowledge, have not been resolved. 8: Fire retardant treated wood shall have a flame spread of not greater than 25. All materials shall bear identification showing the fire performance rating thereof. Such identification shall be issued by an approved agency having a service for inspection at the factory. 9: All wood to remain in placed concrete shall be treated wood. 10: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: New handrail shall comply with IBC Section 1012 "Handrails" as applicable to the ramp. 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D13-286 Printed: 09-05-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) V7-) —1--ge CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION c - - King Co Assessor's Tax No.: Site Address: (0c JC�C Ce � e 5 �L,V Suite Number: Tenant Name: Pace fec PROPERTY OWNER�+ Ate_ Name: t N,C RI Wl at, L.!/' (vC(y 5 Address: S % Io -e City: �� t .iAA State:,1 ar- Zip: %. tie CONTACT PERSON — person receiving all project communication Name: R 0 / An / 44✓7 Address: Z12 1 / "may wie U e,t, _ or s City: 08. Sigel/? -Gs State: (j4 Zip:eigl. Phone: m0� ` Zcl s�I Fax: Email: �h0e,„,....„.,,,, , c,,, GENERAL CONTRACTOR INFORMATION Company Name: / /l /' /��,"%mac,' lit 3 GVH f {/ Address: a''a ( ( `vu Uw or Zip:Agrr City: (\ _ s in State: �� Y �! Phone::JZo( 6-2 ydw / Fax: Contr RegCC (XJ(.JE i i. fg3/P p Date:? ,_ S _ ,l3 I Tukwila Business License No.: H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-I l.docx Revised: August 2011 bh 35970Qo222 New Ten Floor: 1/ ant: ❑ Yes ❑ ..No ARCHITECT OF RECORD Name: Company Name: Company Name: Engineer Name: Oar) le l r rel, `7" / Address: Zl z I Wlcr tr aI'��, Architect Name: City: J P / A State: Zip.�t37 I Address: Email: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Company Name: City: State: Zip: Engineer Name: Oar) le l r rel, `7" / Address: Zl z I Wlcr tr aI'��, + .a5--, City: J P / A State: Zip.�t37 I Phone: z53".... RA5__ 7 1 Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page I of 4 BUILDING PERMIT INFORMATION - 206-431-3670 S vvc�. Valuation of Project (contractor's bid price): $ J �� Describe the scope of work (please provide detailed information): r CAC+ Cite0kIcy ec C2•' f v� ,u4a/ recr as f�1eC C ' c P e_ C4 r e Existing Building Valuation: $ /J /35i�%U ' LIQ C - S u -cC ce C -Lit 0e dQQk Cc ,A yrS(ct/ asc tt t �e � tr-v.t t 1c COX Will there be new rack storage? ❑ Yes .. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): I J GI ct 2 Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ No Compact: Handicap: If"yes", explain: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes �No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fortes-Applications on Line \2011 Apphcations\Pennn Apphcatton Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 151 Floor 2"d Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): I J GI ct 2 Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? ❑ Yes FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ No Compact: Handicap: If"yes", explain: ❑ Sprinklers ❑ Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? ❑ Yes �No If "yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Fortes-Applications on Line \2011 Apphcations\Pennn Apphcatton Revised - 8-9-11.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER.OWA HORIZED AG Signature: Print Name: Date: C / / / ��� Day Telephone: —EC -T-0 O t Mailing Address: 222-1,V. �% (Jl�Q.� Cid v ' a`V�Jch. LO H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh City State Zip Page 4 of 4 AUTHORIZATION FOR ALTERNATE PLAN SUBMITTAL (LIMITED SCOPE OF WORK) IBC & IRC Section 104.1 Date: C17/Z-0 1 E Permit/Application Number: \I1'5 21(0 Address: 6Mt BLV Tukwila, WA 981 Description of Work: 5 N —'I ED 1. ""#t 6rLioTIi1 (1.1 l-IKE K 1 N D, AVPC'O AD.eGK G wl %�- rid& c DX -+ 1/2144K) W,17( by ANS -i2:c-K COATI Nci The above project permit applicant, due to the limited scope of work, is authorized to submit reduced plan requirements described below: 1. Complete permit application(s): Building ❑ Mechanical ❑ Plumbing/Gas Piping ❑ Electrical ❑ Other 2. Plan and/or Specification (minimum): ❑ Site Plan ❑ Floor Plan ❑ Elevations ❑ Foundation ❑ Structural Calcs ❑ Cross Sections ❑ Roof Plan Narrative ❑ Narrative WSEC Compliance 3. Required Inspections (only completed when to be issued over the counter): XFraming ❑ Glazing Final ❑ Other: 4. Other Special Instructions: 0tJ17tTlb N ( 44t7 .tL til-EAu.. ce,m pu t L3 (rt"LB6 o N -1O 12 "t- NPRMLW A A?pLiCBLE1i) Authorized By: Printed Name: Date: 9 I3 (Authoriza on vo' 30 days after date) 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone: 206 431-3670 • Fax: 206 431-3665 W:\Permit Center\Templates\Forms\Auth for Reduced Plan Submittal.docx City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.Rov Parcel No.: 3597000220 Address: 6000 SOUTHCENTER BL TUKW Suite No: Applicant: PACIFIC RIM RECEIPT Permit Number: D13-286 Status: PENDING Applied Date: 09/05/2013 Issue Date: Receipt No.: R13-02553 Initials: User ID: JEM 1165 Payment Amount: $681.40 Payment Date: 09/05/2013 01:08 PM Balance: $0.00 Payee: ADAM THEISSEN, POWELL BUILDERS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 07483G ACCOUNT ITEM LIST: Description 681.40 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 676.90 640.237.114 4.50 Total: $681.40 Printerl• na-nS-2n13 INSPECTION RECORD Retain a copy with permit INSPECTION NO: PERMIT NO.'`A:_ CITY OF TUKWILA BUILDING DIVISION ✓"11 6300 Southcenter Blvd., #100, Tukwila. -WA 98188 (206) 431-3670 Permit. Inspection Request Line (206).431-2451. X13-20 Pro' t: iType.¢Inspection�: A -e_, M Am. Ab 41 *- Address: .. �y ' t 0 C 0e) S //G�� a UaA Date Called. � _ e , A AL,-- Special Instructions: Special � p � �/ l co.)A : Date'Wante4.�� l r a.m. 3. (.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: P >i f\ TC" n-\ pc`t P .�. Date: ,L REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcentef Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO, ' PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 1)/3236 Project; f /JAI (t fie .i?,yl Type of Inspection: r-004;4/ Address: nfix2 Scatftie Aly Date Called:. S ecial Instructions: /y. ', / / 4/ Al i%) //4/0/A1 Date Wanted: //"oZ /3 a. p.m. Reque r: %fj Phone No• ElApproved per applicable codes. aCorrections required prior to approval: COMMENTS: �I P -4 ,r c741/4l( J Date: ,o -- 1.. n El PECTION FEE REQ RED. Prior:..lfo next inspection, fee must be ai at 6300 Southcenter Bl d., Suite 10 : Call -to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. 3-2Wo CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 - (206) 431=3670 Permit Inspection Request Line (206) 431-2451 Project: t Project: : (-, �. A, Type f<Inspectipn: ficin A Address: (n 046 Se_ -kliD, Date Called: Special Instructions: Date Wanted: id` - ,.-I a.m. p.m. Requester: Phone No: El Approved per applicable codes: • orrections required prior to approval. COMMENTS: 7C Wei), LI me s o — /V 4 ieJ At T hA s E, ^7/j 0)1 A./ I tJ `1'L. P PC Datef or: , n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd:, Suite 100.• Call to schedule reinspection. Inspe INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 431-2451 Xk� ��3-� PAW: 10 wet( /Z�eAia✓n-I , o,( ,Type,of Inspection:. t -r -A M I nN Address: (00CD0 5G,felQ6. Date Called: � Special Instructions: Q} 0/ 2. 1 5 _ ( ' 8 1-4,EA-A5 Jp Date Wanted: ! - —I ' Al m p.m. Reques er: ; Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: 0 Imo_ v f R_ � Inspec rt Datei O n REINSPECTION FEE F EQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit 3-'b INSPECTION NO. PERMIT NO. �—^'�, /,I CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 P oject: �v 4A -r !s ro Kid( Re v Type_of Inspection: trkk, /t& Adrrdresss: (� a nn Date Called: Special Instructions: : //�� f ff "°',a.m; Date Wanted�� it/ `i'JJ't — f p.m. Requester: Phone No(_7 I/77 9 Approved per applicable codes. orrections required prior to approval. COMMENTS: --S' 1 r - Ala ik !() F p I� J't'As r K A L I j. 1 e .13 Me /- s M ji e riT A r_00 /_--/ (I ,l ke -_sc_a. a e \.,, ,-.Th i , _ Insdector: DateM — (4 —I 3 T V REINSPECTION FEE REQUIRED for to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 1,00. Call to schedule reinspection. f RECEIVED N3V 2 6 2013 BUILDING DEPARTMENT EXISTING BEAM 63/4"x221/2" GLIB 24F -V4 NEW P.T. 6x6 NF*2 POST W/ SIMP. CCQ16SDS2.5 CAF' 4 ABW66Z BASE (OR EQUIV.) NEW 48'x30"x10' CONC. PAD I. "4 BAR 9 6' O.C. 'E.W. DANIEL TYRRELL, P.E. CONSULTING ENGINEER 2121 MERIDIAN EAST, SUITE M18 (253) 568-7991 EDGEWOOD, WA 98371-1006 ' EAX: (253)56&9137 EMAIL: DANTYRRELL@ATT.NET CLIENT: POWELL HOMES PROJECT: 6000 TUKWILA,WAENTERBLVD DATE: 11-01-2013 Project "Pacific Rim Location: Column (REV) Column [2009 International Building Code(2005 NDS)] 5.5 IN x.5.5 IN x 9.0 FT #2 - Hem -Fir - Dry Use Section Adequate By: 15:8% VERTICAL REACTIONS Live Load: Dead Load: Total Load: Vert-LL-Rxn = 6962 lb Vert-bL-Rxn = 6015 lb Vert-TL-Rxn = 12977 lb COLUMN.DATA Total Column Length: 9 ft Uniiraced Length.(X-Axis) Lx: 9 ft Unbraced Length (Y -Axis) Ly: 9 ft Column End Condtion-K (e): 1 Axial Load Duration Factor 1.15 COLUMN PROPERTIES #2 - Hem -Fir )3ase Values Adjusted Compressive Stress: Fc = 575 psi Fc' = 510 psi Cd=1.15 Cp=0.77 Bending Stress (X -X Axis): Fbx = 575 psi Fbx' = 661 psi Cd=1:15 CF=1.00 Bending Stress (Y -Y Axis): Fby = 575 psi Fby' = 661 psi Cd=1.15 CF=1.00 Modulus of Elasticity: E = 1100 ksi E' = 1100 ksi Min. Mod. of Elasticity: E_min = 400. ksi E_min' = 400 ksi Column. Section (X -X Axis): dx = 5.5 in Column Section (Y -Y Axis): dy = 5':5 in Area: . A = 30.25 in2 Section Modulus.(X-X Axis): Sx = 27.73 in3 Section Modulus (Y -Y Axis): Sy = 27.73 in3 Slenderness Ratio: Lex/dx = 19.64 Ley/dy = 19.64 Column Calculations (Controlling Case Only): Controlling Load Case: Axial Total Load Only (L + 0) Actual Compressive Stress: Fc = Allowable Compressive Stress: Fc' _ Eccentricity Moment (X -X Axis): Mx -ex = Eccentricity Moment (Y -Y Axis): My-ey = Moment Due to Lateral Loads (X -X Axis): Mx = Moment Due to Lateral Loads (Y -Y Axis): My = Bending Stress Lateral Loads Only (X -X Axis): Fbx = Allowable Bending Stress (X -X Axis): Fbx' = Bending Stress Lateral Loads Only (Y -Y Axis): Fby = Allowable Bending Stress (Y -Y Axis): Fby' = Combined Stress Factor: CSF = 429 psi 510 psi 0 ft -lb 0 ft -lb 0 ft -lb 0 ft -lb 0 psi 661 psi 0 psi 661 psi 0.84 DT Tyrrell Consulting StruCalc Version 8:0.113.0 11/1/2013 12:54:02 PM page j OADING3DIAGRAM 9rt: A AXIAL=LOADING Live Load: PL = 6962 Ib Dead Load: PD = 5964 lb Column Self Weight: CSW = 51 lb Total Load: PT.::: 12977 lb Project: Pacific Rim Location: Footing (REV2) Footing (2009 international Building Code(2005 NDS)] Footing Sizer 2.5 --FT x4.0 FT x 10:00 IN Reinforcement. in Long Direction: #4 Bars @ 7.00 IN. O.C. / (4) min. Reinforcement; in: Short Direction -center band (Equal to width of short side): #4 Bars @ 7:00 IN. O.C. 1(4) min. Reinforcement in Short Direction -outside bands: #4 Bars @ 3.00 IN. 0.C. / (1) Each band. Section Footing Design Adequate 'FOOTING •P.ROPE RTIES Allowable Soil Bearing Pressure: Concrete Compressive Strength: Reinforcing Steel Yield Strength: Concrete Reinforcement Cover: Qs = 1500 psf Fc = 2500 psi Fy = 40000 psi c= 3 in FOOTING SIZE Width: Length: Depth: Effective Depth:to Top Layer of Steel: W= 2.5 ft L = 4 ft Depth = 10 in d = 6.25 in COLUMN AND' BASEPLATE SIZE Column Type: -Column Width: Column Depth: Wood m = 5.5 in n = 5.5 in FOOTING CALCULATIONS Bearing Calculations: Ultimate Bearing Pressure: Effective Allowable Soil Bearing Pressure: Required Footing Area: Area Provided: Baseplate°Bearing: Bearing Required: Allowable Bearing: Beam Shear Calculations (One Way Shear): Beam Shear: Allowable Beam Shear: Punching Shear Calculations (Two Way Shear): Critical Perimeter: Punching Shear. Allowable Punching Shear (ACI 11-35): Allowable Punching Shear (ACI 11-36): Allowable Punching Shear (ACI 11-37): Controlling Allowable Punching Shear: Qu = 1293 psf Qe = 1375 psf Areq = 9.4 sf A = 10.00 sf Bear = 18296 lb Bear -A = 83566 lb Vu1 = 6766 lb Vc1 = 14063 lb Bo = 47 in Vu2 = 16542 lb vc2-a = 66094 lb vc2-b = 80625 lb vc2-c = 44063 lb vc2 = 44063 lb Short Direction: Bending Calculations: Factored Moment: Mu = Nominal Moment Strength: Mn = Reinforcement Calculations: Concrete Compressive Block Depth: a = 0.46 in Steel Required Based on Moment: As(1) = 0.31 in2 Min. Code Req'd Reinf. Shrink./Temp. (ACI -10.5.4): As(2) = 0.96 in2 Controlling Reinforcing Steel: As-reqd = 0.96 in2 Selected Reinforcement: Short -band: #4's @ 7.0 in. o.c.(4) Min. page DT Tyrrell Consulting of StruCalc Version 8.0.113.0 LOADING DIAGRAM T 10 in 10 in 11/1/2013 12:52:32 PM 1-5.5in—I 1-5.5 In 4ft ( L_ 2.5 ft 3 in 3 In FOOTING LOADING Live Load: PL = 6962 lb Dead Load: PD = 5964 lb Total Load: PT = 12926 lb Ultimate Factored' Load: Pu = 18296 lb Weight to resist uplift w/ 1.5 F.S.: U.R. = 806 lb Long Direction: Bending Calculations: 68610 in -lb Factored' Moment: Mu = 255150 in -lb Nominal Moment Strength: Mn = Reinforcement Calculations: Concrete Compressive Block Depth: Steel Required Based on Moment: Min. Code Req'd-Reinf. Shrink./Temp. (ACI -10.5.4): Controlling Reinforcing Steel: Selected Reinforcement: Reinforcement Area Provided: Development Length Calculations: Development Length Required: 15 in Development Length Supplied: Reinforcement Area Provided: Development Length Calculations: Development Length Required: Development Length Supplied: Out. bands: #4's @ 3.0 in. o.c.(1) Min. As = 1.18 in2 Id = Ld sup 12 in 109776 in -I 169748 in -I a = 0.49 in As(1) = 0.5 in2 As(2) = 0.6 in2 As-reqd = 0.6 in2 Long Dir: #4's @ 7.0 in. o.c.(4) Min. As = 0.79 in2 Ld = Ld-sup = 15 in 21 in 1 • NOTE: CERTAIN AREAS OF THE EXISTING DECK CANNOT BE VIEWED UNTIL SOME DEMOLITION TAKES PLACE. DRAWINGS REPRESENT ENGINEERS BEST GUESS AT ACTUAL FRAMING CONDITIONS. NOTIFY ENGINEER ASAP ONCE FRAMING IS EXPOSED AND REVISED DRAWINGS 4 ENGINEERING ARE REQUIRED. P.T. 6x12 HF1 EXISTING STRUCTURE LOADS: LL = 50psf DL = 55 psi' (21/2' MAX. CONCRETE DECK) P.T. 2x12 F-iF"2 e 12' O.C. SEP 05 2013 rthmir CENTER P.T. 6x12 HFii ia P.T. 2x12 HF"2 e 12' O.C. P.T. 2 NF"I -e P.T. P.T. 6x12 HF"i ------8 _oDBL JSJo P.T. 4x4 HP2 POSTS, TYP. DI3-24b DECK REPLACEMENT OF ALL FRAMING MEMBERS SUFFERING FROM DECAY. P.T. 6x,6 HF"2 POSTS, TYP. DANIEL TYRRELL, P.E. CONSULTING ENGINEER 2121 LiERIDIAN EAST, SUITE 41f3 (252) 568-7991 EDGE1Y000 L';A 411371.1(T;ifj EA% (253) SEES 137 EMAIL' DAN T YRRELl NET CLIENT: POWELL HOMES PLAN: DECK REPAIR 6000 SOUTHCENTER BLVD TUKWILA. WA DATE: 08-28-2013 JOB: 13- EXISTING FDN II fl- u u 30 30 30 30 O 0 30 I 30, O 0 30 30 O 0 0 30 : 30 30 O 0 0 30. 30 30 O ; 30 0 30 30 0 30 O CJ 0 30 30 30 DECK FOUNDATION DANIEL TYRRELL, P.E. CONSULTING ENGINEER 2121 MERIDIAN EAE I. SLIDE 919 12531 588.7991 EDGEWWD. WA 98371.1096 PAX. 1253) 5688137 EMAIL. DAN IYRREI.I. Ail NEl CLIENT: POWELL HOMES PLAN: DECK REPAIR 6000 SOUTHCENTER-BLVD TUKWILA. WA DATE: 08.28-2013 JOB: 13- Contractors or Tradespeople Prir Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&l to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name POWELL RENOVATIONS LLC UBI No. 602710373 Phone 2068248001 Status • Active Address 22211 Marine View Drive S License No. POWELRL939PE Suite/Apt. License Type Construction Contractor City Seattle Effective Date 10/5/2007 State WA Expiration Date 10/5/2013 Zip 98198 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status POWELBI949KD POWELL BUILDERS INC Construction Contractor General Unused 5/4/2006 7/16/2014 Active SHAYCL'991JM SHAYS CONSTRUCTION LLC Construction Contractor General Unused 4/14/2001 4/14/2003 Archived POWELCL024JM POWELL COMPANY LLC, THE Construction Contractor General Unused 4/14/1998 4/14/2001 Archived POWELCR900DB POWELL CARE AND REPAIR LLC Construction Contractor General Unused 3/2/2010 3/2/2012 Expired POWELBL982K1 POWELL BROTHERS LLC Construction Contractor General Unused 5/21/2002 4/14/2011 Out Of Business POWELHB121K3 POWELL HOME BUILDERS INC Construction Contractor General Unused 5/23/1988 3/15/2007 Re - Licensed Business Owner Information Name Role Effective Date Expiration Date PETRICH, ANNMARIE Agent 10/05/2007 Amount POWELL, TODD EASTMAN Partner/Member 10/05/2007 SLPGGL0064801 POWELL, BROOKS BENTON Partner/Member 10/05/2007 Bond Information Bond Company Name DEVELOPERS SURETY Et INDEM CO Bond 1 Page 1 of 2 - Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 748809C 10/01/2007 Until Cancelled $12,000.00 10/05/2007 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 7 Starr Surplus Lines Insurance SLPGGL0064801 03/15/2012 03/15/2014 $1,000,000.00 02/07/2013 6 Starr Surplus Lines Insurance SLPGGL006480003/15/2012 03/15/2013 03/15/2012 $1,000,000.0001/19/2012 5 WESCO INS CO WPP102159700 03/15/2011 03/15/2013 03/15/2012 $1,000,000.0001/19/2012 4 GENERAL FIDELITY INS CO BAG000745800 03/15/2011 03/15/2012 $1,000,000.0002/01/2011 3 GENERAL FIDELITY INS CO BAG000669900 03/15/2010 03/15/2011 $1,000,000.00 02/24/2010 2 BAG000534200 03/15/2009 03/15/2010 $1,000,000.00 01/29/2009 https://fortress.wa.gov/lni/bbip/Print.aspx 09/05/2013