Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit D13-297 - WALSH CONSTRUCTION - TENANT IMPROVEMENT
WHISH CONSTRUCTION 16400 SOUTHCENTER PY D13-297 City oillI'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov DEVELOPMENT PERMIT Parcel No.: 2623049021 Address: 16400 SOUTHCENTER PY TUKW Suite No: Project Name: WALSH CONSTRUCTION Permit Number: D13-297 Issue Date: 10/10/2013 Permit Expires On: 04/08/2014 Owner: Name: LEGACY PARTNERS COMMERCIAL Address: PO BOX 130639 , CARLSBAD CA 92013 Contact Person: Name: MEREDITH MCPOLAND Address: 4312 4 AV NE , SEATTLE WA 98105 Contractor: Name: DAVIS SCHUELLER INC. Address: 20700 44 AV W STE 280 , LYNNWOOD, WA 98036 Contractor License No: DAVISSI105PN Lender: Name: FUNDED BY LEGACY PARTNERS Address: , Phone: 206 349-9225 Phone: 206 775-9400 Expiration Date: 07/01/2014 DESCRIPTION OF WORK: NON-STRUCTURAL TENANT IMPROVEMENT WITH NEW PARTITIONS, FINISHES, AND DOORS. Value of Construction: $30,327.00 Fees Collected: $1,146.63 Type of Fire Protection: SPRINKLERS International Building Code Edition: 2012 Type of Construction: IA Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-297 Printed: 10-10-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied N N N Number: 0 Size (Inches): 0 Start Time: Volumes: Cut 0 c.y. End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: The granting of this permit does not pres construction or the performances work. to this permit. Signature: Print Name: Public: Non -Profit: N Public: Date: 0 d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating uthorized to sign and obtain this development permi and agree to the conditions attached Date: /(//U/c2 Q This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of doc: IBC -7/10 D13-297 Printed: 10-10-2013 this requirement. • 7: There shall be no occupancy of a building until final inspection has been completed and approved by Tukwila building inspector. No exception. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ***FIRE DEPARTMENT CONDITIONS*** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 24: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with doc: IBC -7/10 D13-297 Printed: 10-10-2013 the principal strokes of the letters not less tha 5 inch (19.1 mm) wide. The word "EXIT" shve letters having a width not less than 2 inches (51 mm) wide a the letter "I", and the minimum spacing be n letters shall not be less than 0.375 inch (9.5 mm). Signs larger than e minimum established in section 1011.5.1 of e International Fire Code shall have letter widths, strokes and spacing in proportion to their height. The word "EXIT" shall be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 25: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1006.1, 1006.2, 1006.3) 26: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 30: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 31: A fire alarm system is required for this project. The fire alarm system shall meet the requirements of N.F.P.A. 72 and City Ordinance #2328. 32: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 33: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 34: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 35: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 36: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 37: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 38: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 39: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approvalof such condition or violation. 40: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IBC -7/10 D13-297 Printed: 10-10-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. V 0— 2-6111 Project No. YriAr, Date Application Accepted: d061 Date Application Expires: 09 ! V `i"\ (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION /_ King Co Assessor's Tax No.: _6' 2..`c Site Address: 1 (o' !Ob S Coy, Tenant Name: WAIL k tAit PROPERTY OWNER Name:p(A`..Eci. t/ //Aae1,,,. Q , L�.O Name:, . i- City: (_ 4, t State Zip:c8 ( 0 l Addresss:1 D (p S"5 ti 4t14 S f- 4- $2)12- tZCity: I City: rle tie V Uri State: w Zip:166nd CONTACT PERSON - person receiving all project communication Name:p(A`..Eci. t/ //Aae1,,,. Q , L�.O Address: 419......._ 1�k 4,,,, . I�.II�( 4 . City: (_ 4, t State Zip:c8 ( 0 l Phone: f,LI� e�il�s. Fax: Email: mei, PG.li.4.11 - e 141 S G uaV.vAciminv1.r d)r GENERAL CONTRACTOR INFORMATION Company Name: Ai/ S S1/ „ . ) ,t Address:ZOnab - rt,,,A-ve IA), Ste -/280 City:tiii00I State: /,Ij Zip: 1,2�-, Phone: • - ( s--.1. 7p- S ' 1 getFax: CTT Contr Reg No.: b s11� p Exp�Date: -3 ( 3 Tukwila Business License �_ 09 9,331 s— H:\Applications\Forms-Appltcalions On Line \201 1 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Suite Numbers 6 (f S O 7 Floor: 5 New Tenant: ❑ Yes [. No ARCHITECT OF RECORD Company Name: 1_� 40 ^ , , p �I cs y� s , /V l 'l�?Zi /d/ Architect Name: IC �'Z- l ! ! t e., j Address: ((i/(00 l't/ lost si. . i - / City��' State.ni) Zip:Q VOw Phone: -1 , Q32.2437. I Fax: piaci ' 74.4' lg.". Email:5 in'1ei+ le.r I e o.Vl "ve r . C ENGINEER OF RECORD Name: Vi;1 Company Name: ILA —f J t 1 l Address: Engineer Name: "j itk- f [�Vleii?i) City: Address: State: Zip: City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Vi;1 —f J t 1 l Address: I "j itk- f [�Vleii?i) City: State: Zip: Page 1 of 4 0BUILDING PERMIT INFORMATI 206-431-3670 • 7 00 l Valuation of Project (contractor's bid price): $gt' 30 32 " t " Existing Building Valuation: $ 10.3 WA Describe the scope of work (please provide detailed information): ✓�t2h =e a4t- t 1 , yubuk) Will there be new rack storage? ❑ Yes \.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: /v/y4 Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PPROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No 1f `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Materia! Sa ty ata Sheets. SEPTIC SYSTEM N/A 0 On-site Septic System - For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applicalions\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 1.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC l' Floor f -t 4/^ I A g 2' Floor f4 3rd Floor I ^ Floors thru 5+1/I Ft . _�- 1 1A Basement , 1 /4 ! , I /A J� lq /A I� /A Accessory Structure* (/' Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck V 4/ PLANNING DIVISION: /v/y4 Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes 0 No If "yes", explain: FIRE PPROTECTION/HAZARDOUS MATERIALS: Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No 1f `yes', attach list of materials and storage locations on a separate 8-1/2"x 11" paper including quantities and Materia! Sa ty ata Sheets. SEPTIC SYSTEM N/A 0 On-site Septic System - For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applicalions\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-1 1.docx Revised: August 2011 bh Page 2 of 4 • • PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING9WNER OR AUTHORIZED AGENT: Signature: Date: 9 . 6 ' Print Name: Mrk_eck—In (k[ f t M d Day Telephone:1A jr • 3 W ? 2. Mailing Address: 49)12_, 414Ave.. r\I t H:\ApplicationsWorms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh City State Zip Page 4 of 4 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 2623049021 Permit Number: D13-297 Address: 16400 SOUTHCENTER PY TUKW Status: APPROVED Suite No: Applied Date: 09/20/2013 Applicant: WALSH CONSTRUCTION Issue Date: Receipt No.: R13-02854 Initials: User ID: JEM 1165 Payment Amount: $527.63 Payment Date: 10/10/2013 01:28 PM Balance: $0.00 Payee: KATHY GEHL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 035184 ACCOUNT ITEM LIST: Description 527.63 Account Code Current Pmts BUILDING - NONRES STATE BUILDING SURCHARGE 000.322.100 523.13 640.237.114 4.50 Total: $527.63 Printed 1(1 -1n -2n13 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT ParcelNo.: 2623049021 Permit Number: D13-297 Address: 16400 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 09/20/2013 Applicant: WALSH CONSTRUCTION Issue Date: Receipt No.: R13-02691 Initials: User ID: JEM 1165 Payment Amount: $619.00 Payment Date: 09/20/2013 11:54 AM Balance: $527.63 Payee: KATHY GEAL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 055319 ACCOUNT ITEM LIST: Description 619.00 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 619.00 Total: $619.00 ,a....• Dencin4_r1R Printed: 09-20-2013 �3 INSPECTION RECORD Retain a copy with permit 13'r INSPECTION N0: PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:Typ of Inspection: r. , AJ AL Address: (,4od SC. p kJr�-� Date Called: .- Special Instructions: 1 „Z" Date Wanted: , /l ,�.g1r 3 p.m. Requester: -Phone Nob ! -7 -7 J - 94 40 r Approved per applicable codes. QCorrections required prior to approval. COMMENTS: Inspector: Date: REINSPECTION FEE REQUIRED. rior to next inspection. fee must be paid at 6300 Southcenter Blvd.. ite 100. Call to schedule reinspection. NSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206)431-2451 Project: W \1-S 0 Type of Inspection: S05r<r.LDFD 0EEL! QC, Address: ' Date Called: Special Instructions: Date Wanted: I 0 30 – .t ; (a.m' p.m. Requester: Phone No: proved per applicable codes. Corrections required prior to approval. COMMENTS: C7Lt 4 -ro 1041 .: Insp- tor Date: - n- Uzi- r� RE SPECTION FEE RE r. UIRED. Prior to/next inspection. fee must be id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. 11 t..... INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: WOLSis 60r.l5714,171O?.J Type of Inspection: - f=2Annkt\l& Address: 1 f H(� 9t 0,.\-k 4L1 Date Called: Special Instructions: • S ?/ / -le 53 1 Date Wanted: !0—IS-17, La'm p.m. Requester: Phone No: a. -O I o - c-ic4Dts pproved per applicable codes. Corrections required prior to approval. COMMENTS:. (ao E v(-47- t__7;kr ( 1`0f L 1 ns ect r: Date R NSPECTION FEE REUIRED. Prior t next inspection, fee mine p id at 6300 Southcenter'Blvd., Suite 100 Call to schedule reinspection. t INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit —297 /3=F --Z LA, , PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover, Park East, Tukwila, Wa. 98188 206-575-4407 Project: MIS,/ yea Type of Inspi n: Type /- A N '- AM- Address: Suite #: l6 yao . ''C '41 Contact Per on: Hood & Duct: No Special Instructions: Phone No.: e`' Approved per applicable codes. Corrections required prior to approval. COMMENTS: z5 WA ,,._ syr -- Ars A-4-91 `j GiA,sa�d � u.s 4 Needs Shift Inspection: yea Sprinklers: lea Fire Alarm: / yi., Hood & Duct: No Monitor: Pre -Fire: ivo Permits: • Occupancy Type: 7 Inspector: ,iiii, 5J Date: ///743 Hrs.: / 0 / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit /3 -S - Zs4 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: GG's� (--51? .,iS/ Type of Inspection: Se n ver tier-/ Address: Suite #: �6t/O) Sc %Aiwy „ Sa 1 Contact Person: Special Instructions: ' Phone No.: %Approved per applicable codes. Corrections required prior to approval. .' COMMENTS:. Sprinklers: — S? c k 'C_:. v Q- r— w. . 'a !. , , Hood & Duct: t _\ r1JCL,- ,-k -----O1` r� Fr•+ Pre -Fire: Permits: J 1 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 4---____' Date: //or- 43 Hrs.: / 0 Inspectofr / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 1' INSPECTION RECORD Retain a copy with permit INSPECTION NUMBER 1 • CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 PERMIT NUMBERS �.� � Projekt: / if of 5 � nsilc-/ c7 Type of Inspection: Address: ,.yamContact Suite #:/6 gOO SG P/cw .s -o/ Person: Special Instructions: Permits: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: aeol ah Si fv /e Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector?K 5T, rd Date: //fl h -i a Hrs.: / r $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 /*PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-297 DATE: 09/20/13 PROJECT NAME: WALSH CONSTRUCTION SITE ADDRESS: 16400 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to. Correction Letter # Revision # after Permit Issued DEPARTMENTS: B ilding Division III nPAR/ lin 113 ISD ire Prevention Planning Division \\\ \K 040 Public Works Structural ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete S Incomplete DUE DATE: 09/24/13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 10/22/13 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: • 1 PLAN REVIEW CHECKLIST - (Nonstructural) Permit App. p/? -9.7 By: y Date: IBC Edition �z & State Amend. Project title: 1(.10./f‘ ,rJ - c' +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ Classify the building or portion thereof in accordance with Chapter 3 Determine the type of construction of the building in accordance with Chapter 6. i Determine if the location of building on the site and clearances to property lines and other buildings on the site plan are in accordance with code provisions. S.,1%70 Review for conformity with General building height and area limitations in accordance with Chapter 5. (?)---lieview for conformity with special detailed requirements based on use and Occupancy. Review for conformity with Type of Construction requirements of Chapter 6. Ac, Review for conformity with Fire and Smoke protection features of Chapter 7. Review for conformity with requirements of interior finishes of Chapter 8. Review for conformity with requirements for fire protection systems of Chapter 9. Review for conformity with requirements for means of egress requirements of Chapter 10 Review for conformity with requirements of accessibility in accordance with Chapter 11, and ICC A117.1 Review for conformity with Washington State Energy Code. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ✓ In circle = topic has been reviewed for the application. X In circle = topic is not relevant to proposed scope of work. WALSH CONSTRUCTION - Legacy Southcenter 16400 Southcenter Parkway, Suite 501/509 Tukwila, Washington 98188 SUITE 501/509 PLANNING APPROVED • No ehanges'can be made to these plans without approval from the Planning Division of DCD Approved 8y: ' `6` Date: 0 0 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2013 r1J City of u iia BUILDING VISION FILE COPY Permit No. 1-A272 i Plan review approval Is subject to errors and omissions. Approval of constructon documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field �r.�►" * br�J' aadmowledged: By Date City Of lbkwila BUILDING DIVISION C TY PLAN AREA OF EXPANSION <EY REVISIONS No changes shall allbe made to the scope of work without prior approval of Tukwila Building Division. NM: Revisions will require a new plan submittal and may inc;ude additional plan review fomes. SEPARATE PERMIT REQUIRED FOR 0 Mechanical it Electrical 4 Plumbing Gas Piping City of Tukwila BUILDING DIVISION SUITE #509 PROJECT DATA CODE REFERENCE: 20 IBC IMC IPC IFC, AND 2008 NEC' 2003 ANSI/ ICC USE: OFFICE OCCUPANCY TYPE: CONSTRUCTION TYPE: FIRE SUPPRESSION: NO. of STORIES: BLDG.SF: 57-I FLOOR SF: I -A SPRINKLERED 5 58, 400 11, 680 LEGAL DESCRIPTIO\/ PARCEL \U"lE3ER APN: 262304-9021 LEGAL DESCRIPTION: PARCEL 1 OF CITY OF TUKWILA REVISED SNORT PLAT #77-51-55 AKA BLA #3-79 REC #7904180861 SD PLAT DAF - POR SE 1/4 OF NW 1/4 BEG AT MONUMENTAL INTSN OF C/L'S OF SOUTI-(CENTER PARKWAY 57TH AVE S $ STRANDER BLVD S 164TH ST TH S 8-45-5 E 325.05 FT TH S 0-25-58 E 30.FT TO AN INTSN WITH 5 MGN SD STRANDER BLVD $ TPOB TH CONTG S 0-25-58 E 200 FT TN S 89-45-58 E 350 FT TH 5 0-25-58 E 1093.20 FT TN N 89-43-19 W 626.31 FT TO E MGN SOUTHCENTER PARKWAY TH N 0-57-48 W 1241.85 FT TO A PT OF CURVE TH NLY $ ELY ALG ARC OF CURVE TO RGT RAD 50 FT THRU C/A 91-11-50 79.53 FT TO S MGN STRANDER BLVD TH 5 89-45-58 E 237.72 FT TO TPOB LESS POR OF SD PAR 1 FOR ST UNDER REC NO 8310250922 LESS RD PER SUP COURT ##09-2-19459-9 KNT RECEIVED CITY OF TUKWILA SEP 2 0 2013 PERMIT CENTER DRAM \G I \DEX ARCHITECTURAL DRAWINGS A0.0 A1.2 A1.3 A2.0 A2.1 A2.2 A2.3 AG .1 COVER SHEET GENERAL NOTES EGRESS PLAN DEMO PLAN FLOOR PLAN �b13-2°1'I REFLECTED CEILING PLAN POWER/DATA PLAN WALL TYPES/ DETAILS/ ELEVATIONS SCOPE OE 1kO < INTERIOR REMODEL (T.I.) OF 1,274 USF OFFICE SPACE, NEN PARTITIONS DOORS AND FINISHES. WORK INCLUDES MECHANICAL 4 ELECTRICAL WORK. FURNITURE SYSTEMS ARE NOT PART OF THIS WORK. • •••• 111 — III ■ 111■ LEGACY PARTNERS CDS INC. Architecture and. Interior Design 1660 Wynkoop Street, Suite 1120 Denver, CO 80202 Tel. (720) 932-3300 / Fax. (720) 932-3303 www.legacypartners.com/CDS Approval: TENANTS APPROVAL: Construction Documents THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE LEGACY PARTNERS, CDS INC. NORTHERN CALIFORNIA, AND ARE NOT TO BE REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION BY AN APPROPRIATE MEMBER OF THE CORPORATION. No. Issue or Revisions Date FOR PERMIT 0 k 09/13/13 O rTl Ell"..1 -1 CID 1 Z O l'''•11 Fillimil Cm) ..P4. 0�0 P."11 V1 o0 Pl—i P Q H pz C._) C...) z = c V1 O 4111 � O fi d– E--, t 0 2 0 ,w Stamp: 9941 REGISTERED HITECT SH ;% ETTLER STATE OF WASHINGTON 9103 Date: 09.13.13 Drawn by: MM Checked by: SM Drawing Title: COVER SHEET Scale: AS NOTED Project No: Drawing No: Ao00 • • • • • III ■ 111■ 111� LEGACY PARTNERS CDS INC. Architecture and Interior Design 1660 Wynkoop Street, Suite 1120 Denver, CO 80202 Tel. (720) 932-3300 / Fax. (720) 932-3303 www.legacypartners.com/CDS Approval: TENANTS APPROVAL: Construction Documents AE REV AT 0\S ELECT CAL \OTES GE\ERAL \OTES (CO\T\UE) GE\ERAL \OTES And KIT. Kitchen L Angle @ At LAB. Laboratory Centerline ? Diameter or Round LAM. Laminate # Pound or Number LAV. Lavatory LKR. Locker (E) Existing LT. Light ACOUS. Acoustical A.D. Area Drain ADJ. Adjustable MAX. Maximum AFF. Above finish floor M.C. Meddicine Cabinet AGGR. Aggregate MECH. Mechanical AL. Aluminum MEMS. Membrane APPROX. Approximate MET. Metal ARCH. Architectural MFR. Manufacture ASB. Asbestos MH. Manhole ASPH, Asphalt MIN. Minimum p MIR. Mirror MISC. Miscellaneous BD. Board M.O. Masonry Opening BITUM. Bituminous MTD. Mounted BLDG. Building BLK. Block NUL. Mullion BLKG. Blocking N. North M. Beam BOT, Bottom N.I.C. Not In Contract NO. or # Number CAB. Cabinet NOM. Nominal C.B. Catch Basin N.T.S. Not To Scale CEM. Cement O.A. Overall CER. Ceramic OBS. Obscure C.I. Cast Iron O.C. On Center C.G. Corner Guard CLG. Ceiling O.D. Outside Diameter(Dim) CLKG. CaulkingOFF. Office OPNG. Opening CLO. Closet OPP. Opposite CLR. Clear C.O. Cased Opening PRCST. Pre -cast COL. ColumnPL. Plate CONC. Concrete P.LAM. Plastic Laminate CONN. Connection PLAS. Plaster CONSTR. Construction CONT. Continuous PLYWD. Plywood CORR. Corridor PR. Pair CTSK. Countersunk PT. Point CNTR. Counter P.T.D. Paper Towel Dispenser P.T.D./R Combination Paper Towel CTR. Center Dispenser Receptacle DBL. Double PTN. Partition DEPT. Department P.T.R. Paper Towel Receptacle D.F. Drinking Fountain DET. Detail Q.T. Quarry Tile DIA. Diameter y DIM. Dimension R. Riser DISP. Dispenser RAD. Radius DN. Down R.D.Roof Drain D.O. Door Opening DR. Door REF. . Reference DWR. Drawer REFR. Refrigerator DS. Down spout RGTR. RegisterREINF. Reinforced D.S.P. Dry Standpipe REQ. Required DWG. Drawing RESIL. ResilientLEVEL E. East RM. Room EA. Each R.O. Rough Opening RIND. Redwood E.J. Expansion Joint R.W.L. Rain Water Leader EL. Elevation ELEC. Electrical ELEV. Elevator S; South EMER. Emergency S.C. Solid Core ENCL. Enclosure S.C.D. Seat Cover Dispenser E.P. Electrical Panel board ' SCHED. Schedule EQ. E ual S.D. Soap Dispenser EQPT. Ea ipment SECT. Section E.W.C. Electric Water Cooler SN. Shelf (E) Existing SNR. Shower EXPO. Exposed SI -IT. Sheet EXP. Expansion SIM. Similar p S.N.D. Sanitary Napkin Dispenser EXT. Exterior S.N.R. SanitaryNapkin Receptacle p p F.A. Fire Alarm SPEC. Specification F.B. Flat Bar SQ. Square F.D. Floor Drain S.ST. Stainless Steel FON. Foundation S.SK. Service Sink STA. Station F.E. Fire Extinguisher STD. Standard F.E.C. Fire Extinguisher Cab. STL. Steel F.H.C. Fire Hose. Cabinet STOR. Storage FIN. Finish FL. Floor STRL. Structural FLASH. Flashing SUSP. Suspended FLUOR. Fluorescent SYM. Symmetrical F.O.C. Face of Concrete i empereazng F.O.F. Face of Finish T.G. d Glazing T F.O.S. Face of Studs T.S. Transition Strip FPRF. Fireproof TRO. Tread F.S. Full Size T.B. Towel Bar FT. Foot or Feet T.C. Top of' Curb FTG. Footing TEL. Telephone TER. Terrazzo FURR. Furring T.G. Tongue and Groove FUT. Future THK. Thick T.P. Top of Pavement GA. Gauge T.P.D. Toilet Paper Dispenser GGalvanizedT.V. Television GL.L. Grab Barr G.B. Glass T.W. Top of Wall GND. Ground TYP. Typical GR. Grade UNF. Unfinished GYP. Gypsum U.O.N. Unless Otherwise Noted Hose Bibb UR. Urinal H.B. Ho H.C. Hos ow bre VERT. Vertical HDWD. Hardwood VEST. Vestibule HDWE. Hardware H.M. Hollow Metal W. West HORIZ. Horizontal HR. Hour W C. Water Closet HGT. Height ND. Wood W/O Without I.D. Inside Diameter (Dim.) NP Waterproof INSUL. Insulation WSCT. Wainscot INT. Interior WT. Weight JAN. Janitor JT. Joint 1. PROVIDE NEW LIGHT SWITCHES AS INDICATED ON PLAN. 2. PROVIDE NEW ELECTRICAL DEVICES AS INDICATED ON PLAN. 3, CONTRACTOR TO PROVIDE NEW LIGHT FIXTURES, ENERGY EFFICIENT BALLAST LAMPS AND ASSOCIATED SWITCHING 4. ALL DEVICES AND COVER PLATES, AS CODE ALLOWS, TO BE WHITE UNLESS DEVIATES FROM BUILDING STANDARD, IN WHICH CASE MATCH BUILDING STANDARD. 20. CONTRACTOR SHALL PATCH AND REPAIR ALL FIREPROOFING DAMAGED OR REVEALED BY DEMOLITION. CONTRACTOR SHALL FIREPROOF AS REQUIRED BY CODE ALL NEW PENETRATIONS GENERATED BY THE WORK DESCRIBED IN THESE DOCUMENTS. 21. THE CONTRACTOR SHALL COORDINATE THE LAYOUT AND EXACT LOCATION OF ELECTRICAL/TELEPHONE PANELS, OUTLETS $ LIGHT SWITCHES WITH LP CDS, INC. IN THE FIELD BEFORE PROCEEDING WITH CONSTRUCTION. DIMENSIONS SHOWN ON LP CDS INC. PLANS SHALL GOVERN ALL LOCATIONS. 22. THE CONTRACTOR SHALL VERIFY THAT NO CONFLICTS EXIST IN LOCATIONS OF ANY AND ALL MECHANICAL, TELEPHONE, ELECTRICAL LIGHTING, PLUMBING AND SPRINKLER EQUIPMENT (TO INCLUDE ALL PIPING, DUCTWORK AND CONDUIT) AND THAT ALL REQUIRED CLEARANCES FOR INSTALLATION AND MAINTENANCE OF ABOVE EQUIPMENT ARE PROVIDED. 23. PROVIDE INTERNALLY ILLUMINATED EXIT SIGNS AS REQUIRED BY I.B.C. 24. LIGHTING AND VENTILATION PER I.B.C. 25. PLUMBING INSTALLATION PER INTERNATIONAL PLUMBING CODE. 26 "TYPICAL" MEANS IDENTICAL FOR ALL SIMILAR CONDITIONS,. U.O.N. 27. "SIMILAR" MEANS COMPARABLE CHARACTERISTICS. VERIFY DIMENSIONS AND ORIENTATION ON PLAN. 28. DIMENSIONS NOTED CLEAR OR CLR ARE MINIMUM REQUIRED DIMENSIONS AND CLEARANCE MUST BE ACCURATELY MAINTAINED. DIMENSIONS ARE NOT ADJUSTABLE WITHOUT REVIEW OF OF LP CDS, INC., UNLESS NOTED AS (±). 29. DIMENSIONS TO EXTERIOR WINDOW WALL ARE TO BE FROM FACE OF GYP. BD. SILL 30. DIMENSIONED HEIGHTS ARE FROM TOP OF EXISTING SLAB, U.O.N. l' „ ASA.F.F. , ABOVE FINISH FLOOR. 31. MILLWORK IS TO BE FURNISHED AND INSTALLED BY CONTRACTOR. 32. THE CONTRACTOR SHALL PROVIDE FIRE RETARDANT TREATED WOOD BLOCKING AS REQUIRED BY THE CONTRACT DOCUMENTS IN WALLS BEHIND SHELVING, ETC. ALL BLOCKING AND FURRING SHALL BE FIRE TREATED AS REQUIRED BY BUILDING CODE. 33. ALL INTERIOR PARTITIONS SHALL MEET THE STRUCTURAL REQUIREMENTS OF IBC. 34. ELECTRICAL INSTALLATION PER NATIONAL ELECTRIC CODE. 35.THE CONTRACTOR SHALL COORDINATE INSTALLATION OF N.I.C. ITEMS WITH OTHER TRADES. 36. PROVIDE FIRE EXTINGUISHERS, 2A: 1013:C, SURFACE -MOUNTED, U.O.N. WITH TRAVEL DISTANCE NOT TO EXCEED 75' PER CODE. r 37. SUSPENDED ACOUSTICAL CEILING SYSTEM SHALL BE IN ACCORDANCE WITH THE LATEST RULES OF THE 1.13.C.. THE N.E.C., AND THE STATE SAFETY ORDERS AND ALL APPLICABLE CODES. 38. ALL INTERIOR FINISHES IN ONE HOUR AREAS SHALL BE CONSTRUCTED WITH CLASS 2 MATERIALS; ALL OTHER MATERIALS SHALL BE CLASS 3 FIRE RESISTANT MATERIALS. 31. THE CONTRACTORS SHALL BE RESPONSIBLE FOR VERIFYING THAT ALL MATERIALS, LABOR, INSTALLATION, FABRICATION, ETC. SHALL CONFORM TO ALL CODES AND REGULATIONS OF APPLICABLE GOVERNING AGENCIES. 40. THE CONTRACTOR SHALL PRESERVE AND MAINTAIN ACCESS TO EXISTING EXITS DURING CONSTRUCTION. 41. THE CONTRACTOR SHALL COORDINATE THE LAYOUT OF PARTITIONS WITH LP CDS, INC. PRIOR TO ANY CONSTRUCTION. ANY DISCREPANCY BETWEEN ACTUAL FIELD CONDITION AND DRAWINGS MUST BE WORKED OUT IN THE FIELD TO THE SATISFACTION OF LP CDS, INC., AT NO EXTRA COST. THIS MUST BE CONSIDERED BY THE CONTRACTOR DURING BID PROCESS AND INCLUDED IN THEIR BIDS. 42.SEPARATE PLANS FOR ALL FIXED AND MOBILE FIRE PROTECTION EQUIPMENT AND FIRE ALARM SYSTEMS SHALL BE SUBMITTED TO THE FIRE MARSHALL FOR APPROVAL PRIOR TO INSTALLATION. 43. ALL DECORATIVE MATERIALS SHALL BE MAINTAINED IN A FLAME RETARDANT CONDITION. 44. CTI -IIS SPACE PLAN DOES NOT DEPICT THE LOCATION OF ANY 1. THE LEGACY PARTNERS, CONSTRUCTION DESIGN SERVICES INCORPORATED SHALL BE ABBREVIATED: LP CDS, INC. 2. THE GENERAL CONTRACTOR SHALL PROVIDE LP CDS, INC., CONSTRUCTION DEPT. AND/OR DESIGN DEPARTMENT WITH SHOP DRAWINGS MATERIAL SCHEDULES AND SPECIFICATIONS OF MATERIALS AND EQUIPMENT; AND WORKMANSHIP QUALITY, FOR HIS WORK, AND HIS SUBCONTRACTOR'S WORK PRIOR TO THE COMMENCEMENT OF WORK. THE LP CDS, INC., RESERVES THE RIGHT TO APPROVE OR REJECT SUBMITTALS FOR PROPOSED CONSTRUCTION. 3. THE FOLLOWING CONTRACTORS ARE TO SUBMIT AS-BUILTS WITH CERTIFICATION THAT WORK CONFORMS TO DRAWINGS AND SPECIFICATIONS: ELECTRICAL, MECHANICAL, PLUMBING SUBCONTRACTORS. 4. CONTRACTORS CONTRACTING DIRECTLY WITH LP CDS, INC., FOR SPECIFIED SCOPE OF WORK, SHALL ALSO SUBMIT SHOP DRAWINGS, MATERIAL AND EQUIPMENT SCHEDULES AND SPECIFICATIONS; AS APPLICABLE, FOR REVIEW AND APPROVAL BY LP CDS, INC. 5. CONTRACTUAL OBLIGATION: BY CONTRACTING WITH LP CDS, INC., THE CONTRACTOR(S) PERFORMING WORK DESCRIBED BY THESE DRAWINGS AGREES TO SUBORDINATE OTHER CONTRACTUAL AGREEMENTS PERTAINING TO THIS WORK; TO THE REQUIREMENTS OF THESE GENERAL REQUIREMENTS, AND THE SPECIFICATIONS AND REQUIREMENTS OF THESE DRAWINGS. 6. THE CONTRACTOR(S) SHALL PURCHASE AND MAINTAIN CERTIFICATES OF INSURANCE WITH RESPECT TO NORKMANS COMPENSATION, PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE LIMITS AS REQUIRED BY LAW. THE CONTRACTOR(S) SHALL BE RESPONSIBLE FOR INITIATING, MAINTAINING, AND SUPERVISING ALL. SAFETY P.RECAUTIQ.NS„ IN CONNECTION WITH THE WORK. 7. CONTRACT BID: THE CONTRACTOR SHALL THOROUGHLY EXAMINE THE PREMISES AND SHALL BASE HIS BID ON THE EXISTING CONDITIONS, THE CONTRACTOR SHALL NOTIFY LP CDS, INC., DESIGN DEPARTMENT IMMEDIATELY OF ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS. 8. THE CONTRACTOR IS RESPONSIBLE FOR PAYMENT AND OBTAINING OF ALL PERMITS REQUIRED FOR A COMPLETE JOB. 9. DURING THE BIDDING AND NEGOTIATION PERIOD THE CONTRACTOR SHALL CONFIRM IN WRITING APPROXIMATE ON-SITE DELIVERY DATES FOR ALL CONSTRUCTION MATERIALS AS REQUIRED BY THE CONSTRUCTION DOCUMENTS AND SHALL NOTIFY LP CDS, INC., IN WRITING OF ANY POSSIBLE CONSTRUCTION DELAYS AFFECTING OCCUPANCY THAT MAY ARISE DUE TO THE AVAILABILITY OF THE SPECIFIED PRODUCT. 10. UPON AWARD OF THE CONTRACT, THE CONTRACTOR SHALL ALSO SUBMIT A SPECIFIC .CONSTRUCTION SCHEDULE TO LP CDS, INC., INDICATING THE REQUIRED CONSTRUCTION TIME FOR ALL CONTRACTORS WORK. 11. SUBSTITUTIONS, REVISIONS, OR CHANGES MUST HAVE PRIOR WRITTEN APPROVAL BY LP CDS, INC. 12, CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL MATERIALS AND WORKMANSHIP IN ACCORDANCE WITH CURRENT IBC CODE AND ALL APPLICABLE ORDINANCES INCLUDING CITY AND LOCAL BUILDING CODES AND REQUIREMENTS. 13. NO WORK DEFECTIVE IN CONSTRUCTION OR QUALITY WILL BE ACCEPTABLE IN CONSEQUENCE OF THE OWNER'S OR DESIGNER'S FAILURE TO DISCOVER OR POINT OUT DEFECTS OR DEFICIENCIES DURING CONSTRUCTION. DEFECTIVE WORK REVEALED WITHIN THE TIME REQUIRED BY GUARANTEES SHALL BE REPLACED BY WORK CONFORMING WITH THE INTENT OF THE CONTRACT. NO PAYMENT, EITHER PARTIAL OR FINAL, SHALL BE CONSIDERED AS AN ACCEPTANCE OF DEFECTIVE WORK OR IMPROPER MATERIALS. 14. ELECTRICAL AND MECHANICAL ELEMENTS SHALL BE REMOVED BACK TO THE NEAREST J -BOX, PANEL, PIPE, DUCT, ETC. TO ENSURE NO CONFLICT WITH NEN WORK. ELEMENTS TO BE PROFESSIONALLY SHUT-OFF DISCONNECTED OR CAPPED. COORDINATE WORK WITH BUILDING ENGINEER. 15. PATCH AND REPAIR ALL DISRUPTED WALLS AND REMAINING CEILINGS AS REQUIRED FOR AND SUITABLE FOR RECEIVING FINISH AFTER DEMOLITION BY OTHERS. 16. PROVIDE PROTECTIVE MEASURES AS REQUIRED TO PROTECT IMPROVEMENTS AND TO PROVIDE FREE, UNOBSTRUCTED AND SAFE PASSAGE OF OWNER'S PERSONNEL, GENERAL PUBLIC AND CONSTRUCTION PERSONNEL TO AND FROM OCCUPIED PORTIONS OF THE BUILDING. MAINTAIN AND PROTECT ALL AREAS, OUTSIDE CONFORMING THE DESIGNATED WORK AREAS FROM AREAS FROM DAMAGE, SOIL AND DEBRIS. 17. REMOVE ELECTRICAL AND MECHANICAL ELEMENTS PRESENT IN WALL AND/OR STRUCTURES NOTED FOR DEMOLITION UNLESS SERVING OTHER PORTIONS OF THE BUILDING. 18. THE CONTRACTOR SHALL REPAIR ANY DAMAGE TO THE FACILITY CAUSED BY THE DEMOLITION ACTIVITIES OR BY HIS SUB- CONTRACTORS AT NO COST TO THE OWNER. EXISTING DAMAGE PRIOR TO ANY DEMOLITION WORK SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER BEFORE SUCH WORK BEGINS. 19. PATCH, REPAIR AND REPLACE CEILING TILE AND GRID AS " REQUIRED FOR A LIKE NEW APPEARAken5NCE. 4.. J..917 RECEIVED CITY OF TUKWILA SEP 2 0 2013 PERMIT CENTER \ / p v ®V AC/I LU E3I\G \OTES 1. REUSE (E) MECHANICAL ROOF UNITS. REWORK (E) DUCTING AND RE -BALANCE AIR DISTRIBUTION. 2. REUSE (E) SPRINKLERS. ADJUST TO ACCOMMODATE NEW CEILING SYSTEM LAYOUT AND HEIGHT. SPRINKLER HEADS TO BE CENTERED WITHIN 2'X2' GRID AND SEMI RECESSED SILVER ESCUTCHEONS 3. PLUMBING WORK SHALL INCLUDE WASTE LINES, VENT LINES, CONDENSATE LINES AND WATER LINES, CONCRETE SAWING AND PATCHING FOR THESE ITEMS. 4. PLUMBING FIXTURES SHALL INCLUDE ITEMS NOTED IN PLUMBING FIXTURES AND ACCESSORIES SCHEDULES AS STANDARD ITEMS, UNLESS NOTED OTHERWISE, OR MARKED N.I.C. IN REMARKS COLUMN. 5. FIXTURES AND ACCESSORIES SHALL BE STANDARD UNLESS OTHERWISE NOTED G. WATER PIPING MATERIAL: TYPE "L" HARD -DRAWN COPPER WATER TUBE AND WROUGHT SOLDER TYPE FITTING. 7. ALL PIPING AND DUCTWORK SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS OF IMG. �U I LDS \G ACCESS \OTES ES ENTRANCES: 1. ALL PRIMARY ENTRANCES SHALL BE ACCESSIBLE. 2. LEVEL SPACE PROVIDED AT STRIKE SIDE OF OUT SWINGING DOORS: 5 -0 X 5 -0 " 3. SPACE SHALL BE PROVIDED AT STRIKE SIDE OF OUT SWINGING EXTERIOR DOORS: 2'-0" SPACE WHEN DOOR SWINGS 4. AWAY FROM APPROACH SHALL BE 3'-8° 5. ENTRANCE WIDTH, MINIMUM 2'-8" CLR. OPENING: 3'-0" DOOR. 6. DOUBLE DOOR REQUIRED WIDTH: ACTIVE LEAF MUST HAVE 2'-8" CLEAR OPENING. 7. UNINTERRUPTED SMOOTH SURFACE SHALL BE PROVIDED ON DOOR BOTTOM: 10" HIGH ON PUSH SIDE. DOORS, INTERIOR AND EXTERIOR: 1. LEVEL SPACE SHALL BE PROVIDED ON SWING SIDE OF 5'-0'. h' 2. LEVEL SPACE AWAY FROM SWING SIDE SHALL BE 4 -8 . 3. 1'-6" SPACE SHALL BE PROVIDED ON STRIKE SIDE OF INTERIOR DOOR. 4. MINIMUM ACCESSIBLE DOOR WIDTH IS 2'-8"' (3'-0"DOOR) „ 5. MINIMUM ALLOWABLE DOOR HEIGHT IS 6 -8 . DOOR HARDWARE 1. HARDWARE SHALL BE LEVER, PUSH -PULLS, OR PANIC. DEVICES, OPERABLE BY A SINGLE EFFORT; NO GRASPING OR WRIST MOVEMENT. REFER TO BLDG. STD. SPEC. LIST FOR SPECIFIC MFR. AND TYPES. 2. CLOSERS: ALLOWABLE INTERIOR CLOSER PRESSURE 5 POUNDS ALLOWABLE EXTERIOR CLOSER PRESSURE 8.5 POUNDS ALLOWABLE FIRE DOOR CLOSER PRESSURE 15 POUNDSEXISTING THRESHOLDS MAXIMUM ALLOWABLE HEIGHT IS 1/2', WITH 45 DEGREE BEVEL. FLOORS ONLY SLIP RESISTANT SURFACES ARE ALLOWED. CORRIDORS ASBESTOS -CONTAINING MATERIALS. ALL PARTIES MUST CAREFULLY REVIEW THE BUILDING'S ASBESTOS OPERATIONS AND MAINTENANCE PROGRAM IN POSSESSION OF OWNER TO ASCERTAIN THE LOCATION OF ANY ASBESTOS -CONTAINING MATERIALS IN THE BUILDING. REVIEWED FOR , CODE COMPLIANCE APPROVED OCT 0 9 2013 • City Of Tukwila BUILDING DIVISION ALLOWABLE MINIMUM WIDTH FOR CORRIDORS IS 31-8". 2, ALLOWABLE MINIMUM WIDTH FOR AISLES IS 3'-0" CONTROLS FOR LIGHTS, WINDOWS, TEMPERATURE, AND OTHER DEVICES. 1. MAXIMUM HEIGHT ABOVE FINISH FLOOR: 4'0', U.O.N. MINIMUM HEIGHT ABOVE FINISH FLOOR: 3'0". 2. WALL OUTLETS FOR TELEPHONES AND POWER SHALL BE A MINIMUM OF 15 ABOVE THE FINISH FLOOR. EXCEPTIONS: RELOCATABLE PARTITIONS, AND WINDOW WALLS." HAZARDS 1. OVERHEAD OBSTRUCTIONS SHALL BE 6'8" MINIMUM. 2. PROJECTIONS SHALL BE A MAXIMUM OF 4 INCHES IF OVER 2'-3" ABOVE FLOOR. 3. A TEXTURED PATH SHALL BE PROVIDED WHEN OBSTRUCTIONS ARE IN THE PATH OF TRAVEL. 4. EMERGENCY SIGNALS ARE TO BE AUDIBLE AND VISUAL. • • • • • III ■ 111■ 111� LEGACY PARTNERS CDS INC. Architecture and Interior Design 1660 Wynkoop Street, Suite 1120 Denver, CO 80202 Tel. (720) 932-3300 / Fax. (720) 932-3303 www.legacypartners.com/CDS Approval: TENANTS APPROVAL: Construction Documents THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE LEGACY PARTNERS, CDS INC. NORTHERN CALIFORNIA, AND ARE NOT TO BE REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION BY AN APPROPRIATE MEMBER OF THE CORPORATION. No. Issue or Revisions Date LEGACY SOUTHCENTER PARKWAY 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 w Stamp: 9941 REGISTERED CHITECT SH ..., METTLER STATE OF WASHINGTON q 1 /3 Date: 09.13.13 Drawn by: MM Checked by: SM Drawing Title: GENERAL NOTES Scale: AS NOTED Project No: Drawing No: A1 02 CODE SU ' 'ARY PLA LONGEST PATH OF— EGRESS TRAVEL 701 - 6II LEGE\D: EXIT ILLUMINATED EMERGENCY EGRESS SIGN 6,890 SF / 100 SF per occ, = 69 occupants 2 EXITS REQUIRED, 3 PROVIDED REVIEVVEp F6R CODE COMPLIANCE APPROVED OCT 0 9 2013 City of Tukwila BUILDING DIVISION D rr7 RECEIVED CITY OF TUKWILA SEP 2 0 2013 PERMIT CENTER Drawing No: AL5 Architecture 1660 Wynkoop Tel. (720) 932-3300 www.legacypartners.com/CDS Approval: Design 1120 932-3303 ••••• III ■ 111 111 LEGACY PARTNERS CDS INC. and Interior Street, Suite Denver, CO 80202 / Fax. (720) TENANTS APPROVAL: Construction Documents THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE LEGACY PARTNERS, CDS INC. NORTHERN CALIFORNIA, AND ARE NOT TO BE REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION BY AN APPROPRIATE MEMBER OF THE CORPORATION. No, Issue or Revisions Date ff • FOR ,PERMIT 0 kn0 ''S >''q 09/13/13 002 knW E-4 1 1 Z C.) F—..1 F-4 Li) ri E.IIII On cl.) 14 00 C:::h 4:"I P4 W A-, 0 c..oZ 44 � W E.--1 =z ��H V) O 0 0 0 Stamp: 9849 REGISTERED '' CHITECT it SH'I PETTLER STATE OF WASHINGTON q/3/3 Date: 09.13.13 Drawn by: MM Checked by: SM Drawing Title: EGRESS PLAN Scale: AS NOTED Project No: Drawing No: AL5 GE\ERAL \OTES REMOVE (E) PARTITIONS AS SHOWN TO BE DEMOLISHED, INCLUDING BUT NOT LIMITED TO ELECTRICAL OUTLETS, WIRING, ATTACHMENTS $ BRACING (TYPICAL). FIRE EXTINGUISHERS ON REMOVED WALLS SHALL BE RELOCATED. 2. REMOVE ALL FLOOR COVERINGS THROUGHOUT. 3. THERMOSTATS ON REMOVED WALLS SHALL BE RELOCATED. 4. SALVAGE ALL DOORS AND RELITES TO BE DEMO'D DE vo SY1'13OL LEGE\D EXISTING PARTITION TO BE REMOVED EXISTING PARTITION TO REMAIN LIGHT SWITCH TO BE REMOVED DUPLEX RECEPTACLE TO BE REMOVED PHONE/DATA JACK TO BE REMOVED FOUR-PLEX RECEPTACLE TO BE REMOVED BLANK RECEPTACLE TO BE REMOVED RCP DE'0 SY'3OL LEGE EXISTING 2X4 LIGHT FIXTURE TO BE REMOVED/ RELOCATED , 0 EXISTING RECESSED CAN LIGHT FIXTURE TO BE REMOVED/ RELOCATED <EYED S EET \OTES O REMOVE/ RELOCATE DOOR ASSEMBLY. REFER TO CONSTRUCTION PLAN FOR ADDITIONAL INFORMATION. 0 REMOVE EXISTING CASEWORK AND PLUMBING, CAP PLUMBING BACK AT SOURCE. O EXISTING UPPER CABINETS TO REMAIN. O REMOVE EXISTING FLOORING AND BASE AT THIS LOCATION, REFER TO CONSTRUCTION/ FINISH PLAN FOR EXTENTS. KEYED ALTER\ATE S�IEET TO BE PRICED AS SEPARATE OTES LINE ITEM • REMOVE PORTION OF EXISTING PARTITION, REFER TO CONSTRUCTION PLAN FOR EXTENT. O REMOVE/ RELOCATE DOOR ASSEMBLY. REFER TO CONSTRUCTION PLAN FOR ADDITIONAL INFORMATION. • O REMOVE EXISTING CLERESTORY SIDELIGHT ASSEMBLY, RELOCATE PER CONSTRUCTION PLAN. O REMOVE/ RELOCATED TENANTS FAX COUNTER, REFER TO PLAN FOR ADDITIONAL INFORMATION. <EYED REFLECTED CEILI\G PLA\ \OTES O REMOVE EXISTING B/S CORRIDOR CEILING TILE AT THIS LOCATION. COORDINATE STORAGE (IF ANY) OF UNDAMAGED TILES WITH BUILDING MANAGEMENT. O REMOVE EXISTING LIGHT FIXTURES AT THIS LOCATION. COORDINATE STORAGE (IF ANY) OF FIXTURES WITH BUILDING MANAGEMENT. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2013tv161' City of Tukwila 1441 BUILDING DIVISION �i/ 1111■■■, 1111■■■■ � , II ■I IIII/1 Ez _ � � � C 1 �►I■IIII/II �� � � �. s■■■■■■■■■ ■■■■= ..g■� 11111 IIA \ = 1 w■ ■■■�■■■■ ■■■ I■■■■ 1111■■ C�■r■ _Ina = 110111111111111111 r ■■■■■■■■■■■■■■ � ■■■■■■■■■■II■■i■wlA1111■■ � � ------ ■II ■■II \■■■■■■■■■■■■II■/■%ll w � 1111 ral- �■■■ 111/111114111111111111A ■■■■■■©II■/111/II©■II ■ 1111 11111111111111111111111.1111111■■�■ 1113■■■■l■■®■■■■©■■■II■111E 1 1111 \■■■■M`\■■■■■■■■■■L- 11 --- ■1111■ __ I■1 ■■■ 11111711111E41111111/1111PMEIMIIIIIIIIMINK11111111111111:10:11P ■ � J _ �■�■CJS■e!!�!■1■■: ■�'�\\■►1111■■ ■■■■■■■�■■■■■■■■rrr■I �iii�(i■`�iTil�ii■iii■iiii■1 ■II■■1�1■■■■■ ■■■■���►t0�■■■► 1111■■I ■� ■■■sem � i ■■1�..�■■■■■■■\\■1■■■II■1■■■■■1111■\\1111„ � 1111■ �■--------� ■\\■�I \\■I ■■■1111 11111•111111111111111111 MEW ■/I■i\■■■■■■■■■■■■Ile■■■■e■■111■e■■■111.r-�■■■■■II■■1101■■11,1iiiliiii■■■ 1 • /"1■■■■■\ ININIM ■■■■■■111.11■■s\■111■■■■■I■II■©II■■II■©■■■■©■1111■sLI\\■II X111 1 1111■■O1/�■\J■I / \1111■■■\\1111■\\ ,\\■■I■I 1111► ■■il■■■■■■■■■111■■■■■■II■ ! � , � �� ,. � � � ---- 1111 ■■II■■\\1111\\■1111■II■■©■■��.!�`!�il■■■I ■4. . m■■■�m■Ali■mEmmu■■■■■■II■■■■■■■■111111/I �• - 0 ■t1 ■ ■ MammmS■mmmE■■■■w■ra■Mi■■\■I 111111191Tern2=EMILICEIMILIMISPUNIST mossoriummimmesmommimmmtwormmimommEmmiltammor NEIIIIIIIMIIMIIIMMEMIIIIEMOMMIIIMEI ■■111■®■�� �� �wI`�L©,� (1,.,\RCF DEMO PLA\ SCALE: I/8"=1'-0° �■�®1111►.`.11■■■■i■■1311■ ®s\■■1113■■■ \11111MERIZI1111111111111ffidiraisitallallipr___=,!�■1■■fir■\\1111■►■■■■■III uIJ■■■■■■\iU1111 ■■►\\■/" !11111111111111111111i11111111111111111111LISSF11\�,�J■■so■■1IiiiiiIi•DUIIII ■13■■■■©II©jr. ■ su ■■■■ is ■\\■■p' \ Illairj 4)--q*-7 RECEIVED CITY OF TUKWILA SEP 2 0 2013 PERMIT CENTER 111 '1' - ''‚ LEGACY PARTNERS CDS INC. Architecture and Interior Design 1660 Wynkoop Street, Suite 1120 Denver, CO 80202 Tel. (720) 932-3300 / Fax. (720) 932-3303 www.legacypartners.com/CDS Approval: TENANT'S APPROVAL: Construction Documents THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE LEGACY PARTNERS, CDS INC. NORTHERN CALIFORNIA, AND ARE NOT TO BE REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION BY AN APPROPRIATE MEMBER OF THE CORPORATION. No. Issue or Revisions Dote FOR c..), tr, ,....kr,......„..., ., 0 PERMIT 09/1343O F...., ...-1 ',-.:::) V ) 1 -,iEP_F, CD ...i EN -4 c....) 00 00 P4 H.1111 oc ww� E-4 p4 CD:.T4 �w� E__, cC, V 1 0 [� �;o o �-�HU O 0 Stamp: 9941 REGISTERED CHITECT S ETTLER STATE OF WASHINGTON Date: 09.13.13 Drawn by: MM Checked by: SM Drawing Title: DEMO PLAN Scale: AS NOTED Project No: Drawing No: A2/ LEGE\D: EXISTING TO REMAIN 0 0 FE NEW INTERIOR PARTITION, INCLUDES 2-I/2" METAL STUDS AT 24" O.C. (OR MATCH EXISTING) WITH 1 LAYER 5/8" TYPE "X" GYP. BD BOTH SIDES. REFER 1/A.6.1 NEN BUILDING STANDARD INTERIOR INSULATED PARTITION. INCLUDES 2-1/2" (OR MATCH EXISTING) METAL STUDS @ 24" O.C. NITH 5/8" TYPE "X" GYP. BD. BOTH SIDES AND 2-1/2" UNFACED BATT INSULATION. 4' OF BATT INSUL. ON BOTH SIDES OF DEMISING NALL IN CEILING. 2/A.6.1 NEN CASEWORK LINE OF UPPER CABINETS GLASS WITH FRAME FIRE EXTINGUISHER GENERAL \OTES 1 ALL EXISTING SURFACES DAMAGED OR DISTURBED BY ALTERATIONS SHALL BE PATCHED, PAINTED, REPAIRED OR REPLACED (UNLESS OTHERWISE NOTED). REPAINT TO NEAREST NATURAL BREAK. 2. REWORK EXISTING HVAC, INCLUDING RELOCATING THERMOSTATS, TO ACCOMMODATE NEW LAYOUT. 3. DIMENSIONS SHOWN ARE FROM FACE OF FINISH UNLESS SHOWN OTHERWISE. 4. PROVIDE INDIVIDUAL SUPPLY AND RETURN AIR DIFFUSERS IN EACH ENCLOSED SPACE. UNDERCUTTING OF DOORS OR USE OF GRILLS IN DOORS IS NOT ACCEPTABLE FOR RETURN AIR. 5. FINISH ON ALL NEW WALLS TO MATCH EXISTING, UNLESS OTHERWISE NOTED. 6. REMOVE ALL BULLETIN BOARDS, SUPPORT BOARDS FOR REMOVED ITEMS, UNNECESSARY SIGNS ETC; PATCH AND REPAIR ANY WALL DAMAGE AT AREA OF CONSTRUCTION. 7. CLEAN HVAC GRILLES THROUGHOUT AREA OF CONSTRUCTION SPACE. CONTRACTOR SHALL VERIFY REPAIRS WITH EXISTING TILES AND PROVIDE A MATCH TO TENANT FOR APPROVAL PRIOR TO INSTALLATION OR REPLACE ALL TILES IF A MATCH IS NOT POSSIBLE. 8. CLEAN ALL MINI -BLINDS AT GLAZING AS REQUIRED, BAG AND PROTECT THROUGHOUT CONSTRUCTION. 9. ALL COVER PLATES, INCLUDING BUT NOT LIMITED TO SNITCHES, OUTLETS OR FIRE/SAFETY DEVICES SHALL MATCH EXISTING. REPLACE AS NECESSARY. 10. ALL WOOD USED IN INTERIOR FRAMING IS TO BE FIRE RETARDANT TREATED WOOD. 11. CONTRACTOR IS TO FIELD VERIFY ALL EXISTING CONDITIONS PRIOR TO COMMENCEMENT OF WORK. KEYED SWEET \OTES O EXISTING FLOORING, PAINT AND BASE TO REMAIN. O CONFIRM ACCENT NALL COLORS AND PROPOSED LOCATIONS WITH TENANT PRIOR TO PAINTING. KEYED ALTERNATE SHEET NOTES PROVIDE LINE ITEM PRICING • PROVIDE PRICE TO REMOVE AND RE -CARPET ENTIRE NEWLY ENLARGED OPEN OFFICE. CONFIRM WITH TENANT. O RELOCATED CLERESTORY LOCATION O RELOCATED DOOR ASSEMBLY LOCATION. ® RE -INSTALL TENANTS FAX COUNTER AT THIS LOCATION CENTER ON NALL. SY SOLS r0-: DOOR MARK (NEN) ( (E DOOR MARK (EXISTING) NEW OFFICE 530 NEW OFFICE EXISTING OFFICE \35 HALLWAY OPEN OFFICE (E) EXISTING OFFICE EXISTING OFFICE OPEN OFFICE BREAK ROOM RECEPTIO WORK ROOM ) 500 OPEN OFFICE 526 EXISTING OFFICE 518 PREP EXISTING OFFICE 506 1� CO\STRUCT } SCALE: I/8"=1'-0" 503 HALLWAY EXISTING OFFICE 525 (E) (E) (E) 0\/ FI\ IS EXISTING OFFICE 508 EXISTING /• OFFICE 517 /EXISTING OFFICE 516 EXISTING OFFICE PLA\ EXISTING OFFICE 509 r EXISTING OFFICE 510 EXISTING OFFICE 511 EXISTING OFFICE 512 EXISTING OFFICE 513 FINISWES: TYPE: MANUFACTURER SPECIFICATION BASE B-1 JOHN SON ITE COLOR: 11 CANVAS (MATCH EXISTING) 4" CARPET CPT -1 CPT -2 PAINT BIGELOW PATTERN:MADE TO MOVE 80219 BIGELOW PATTERN: SPECTRUM V COLOR: 7916 TAKE CHARGE INSTALLED: TBD COLOR: 2825 TATAMI TAN INSTALLED: AT DOOR THRESHOLDS P-1 SHERWIN WILLIAMS GENERAL, EGGSHELL COLOR: TBD P-2 SHERWIN NILLIAMS ACCENT, EGGSHELL COLOR: TBD P-3 SHERWIN WILLIAMS ACCENT, EGGSHELL COLOR: TBD GE\ERAL FINISW \OTES: 1. PROVIDE NEN P-1 THROUGHOUT EXPANSION/ CONSTRUCTION AREAS, UON. 2. PROVIDE NEN 5-1 THROUGHOUT EXPANSION/CONSTRUCTION AREAS, UON. 3. PROVIDE NEN CPT -1 THROUGHOUT EXPANSION/CONSTRUCTION AREAS, UON. EXISTING CONFERENCE 514 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2013 City of Tukwila BUILDING DIVISION EXISTING OFFICE 520 b1 -7D 1'17 RECEIVED CITY OF TUKWILA SEP 2 0 2013 PERMIT CENTER ••••• 111 111 III ■ LEGACY PARTNERS CDS INC. Architecture and Interior Design 1660 Wynkoop Street, Suite 1120 Denver, CO 80202 Tel. (720) 932-3300 / Fax. (720) 932-3303 www.legacypartners.com/CDS Approval: TENANTS APPROVAL: Construction Documents THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE LEGACY PARTNERS, CDS INC. NORTHERN CALIFORNIA, AND ARE NOT TO BE REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION BY AN APPROPRIATE MEMBER OF THE CORPORATION. No, Issue or Revisions Date FOR PERMIT C 0 09/13/13 nimmilO ¶ k immT Fili 11°1 V1 1 Z (::::) Ellmil Como) ''' o0 ,—i r24 oo Ch E""—I P-4 V P W O CD c...) V 4.1 W F--( r C..) ��C% 43 c... ? U a) 0 A Stamp: 9941 REGISTERED �, . RCHITECT S '�METTLER STATE OF WASHINGTON ?G!'S Date: 09.13.13 Drawn by: MM Checked by: SM Drawing Title: FLOOR PLAN Scale: AS NOTED Project No: Drawing No: A27 4 - #12 GA. SEISMIC SPLAY BRACE WIRES 2 - #12-14 SCREWS AT STUD TO T -BAR ATTACHMENT COMPRESSION STRUT - SEE SCHEDULE BELOW FOR TYPE, SIZE tt NUMBER. ATTACH AT PURLIN ABOVE N/2 - 148 SHEET METAL SCREWS. DO NOT ATTACH TO 2X4 STIFFENERS. DOUBLE STUDS CONNECTED W/1 #6 SHEET METAL SCREW 16" 0.0. BOXED STUDS MAY BE USED AT NALL BRACING NOTE: SPACE SEISMIC SPLAY BRACE WIRES t COMPRESSION STRUT AT NO MORE THAN 12'-0" 0.C. IN EITHER DIRECTION. CEILING GRID SCHEDULE METAL STUD OR EMT MAX. HT. 3-5/8" X 20 GA. 9'-6" DBL. 2-1/2" X 20 GA. 16'-6" DBL. 3-5/8" X 20 GA. 24'-0" 1-1/2" EMT 10'-5" 1-1/4" EMT 12'-11" 2" EMT 18'-4" SEISMIC BRACING BRACING PTS. @ 8'-0" 0.C. EA. WAY (DIAL WIRES) FIRST PT. @ 6'-0" MAX FROM EACH NALL HANGER WIRES @ 4'-O" O.C. MAIN RUNNERS @ 4'-0" 0.C. / / I / CROSS RUNNERS @ 2'-0" 0,C. DIAGRA"MATIC FRA 'U\ G PLA\ 2 CEILI G LEGEND: 0 OR 0 EXISTING 2'x4' T -BAR SUSPENDED CEILING GRID WITH SUITE STANDARD ACOUSTICAL CEILING TILES SPEC: MATCH EXISTING EXISTING 2X4 LENSED FLUORESCENT FIXTURE R RELOCATED 2X4 LENSED FLUORESCENT FIXTURE RECESSED CAN LIGHT FIXTURE RELOCATED CAN LIGHT FIXTURE EXISTING SPRINKLER LOCATION, FOR REFERENCE ONLY. BLDG. STANDARD EXIT SIGN LIGHT SWITCH EMERGENCY LIGHTING R = RELOCATED N = NEW REFLECTED CEILING NOTES: 1. THESE DESIGN DRAWINGS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES. SNITCHING AND CIRCUITING SHALL BE DESCRIBED ON ENGINEER'S ELECTRICAL DRAWINGS, AND INSTALLED AS DIRECTED THEREIN. 2. ALL SNITCHING SHOWN SHALL BE 44" A.F.F. TO CENTERLINE OF COVERPLATE. MULTIPLE SWITCHES SHOWN AT THE SAME LOCATION SHALL BE GANGED AND FINISHED WITH A ONE PIECE COVERPLATE. ALL SWITCHES TO HAVE WHITE COVERPLATES. 3. VERIFY THAT ALL EXISTING LIGHT FIXTURES, TUBES, BALLASTS, EXIT LIGHTS, BATTERY PACK BACK-UPS, ETC. ARE OPERATIONAL. REPAIR/REPLACE AS REQUIRED N/ COOL WHITE BULBS. CLEAN LIGHT LENSES THROUGHOUT. 4. FIRE SPRINKLER CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS OF SPRINKLER LOCATIONS. ADD AND/OR RELOCATE SPRINKLER HEADS AS REQUIRED TO ACCOMMODATE NEN LAYOUT. 5. INSTALL SMOKE DETECTORS IN EXISTING AND NEN MECHANICAL UNITS AS REQUIRED BY CODE. 6. ALL EXISTING AND NEN DEVICES AND COVERPLATES TO MATCH EXISTING. 7. CLEAN/ REPAIR OR PAINT EXISTING CEILING GRID AND TILE FOR LIKE -NEN APPEARANCE. 8. VERIFY THAT ALL EXIT SIGNS COMPLY WITH THE BUILDING STANDARD NHITE SIGNS. INSTALL NEN AS NEEDED. CLEAN/ REPAIR EXISTING SIGNS FOR LIKE -NEN APPEARANCE. 9. REPAIR OR REPLACE NON-FUNCTIONING LIGHT FIXTURES. 10. CONTRACTOR SHALL PROVIDE EGRESS ILLUMINATION PER IBC 2009. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF THE SYSTEM UNDER THE DESIGN BUILD CONTRACT. VERIFY WITH BUILDING MANAGEMENT AND PROVIDE FULL COMPLIANCE TO THE NEN SPACE Il. REVIEW ALL FIRE LIFE SAFETY EQUIPMENT LOCATIONS (INCLUDING BUT NOT LIMITED TO HORNS, STROBES) WITH DESIGNER PRIOR TO INSTALLATION. EXISTING OFFICE 520 SERVE OFFIC EXISTING OFFICE 504 EXISTING OFFICE EXISTING OFFICE Erna' 1111 501 � 1112.1.72 111111MINEAMINE IMW\/ EXISTING OFFICE EXISTING OFFICE WORK RCOM OPEN * 57fi REFLECTED C=ILI\ SCALE: 1/8"=1'-O" EXISTING OFFICE 508 EXISTING OFFICE EXISTING OFFICE .516 G PLA\ EXISTING OFFICE 509 NEW OFFICE 510 NEW OFFICE 511 NEW OFFICE 512 NEW OFFICE 513 KEYED REFLECTED CEILI \G NOTES REWORK SUITE SNITCHING AS REQUIRED FOR NEN SUITE EXPANSION LAYOUT. ALL OPEN AREA LIGHTING SHALL BE SNITCHED TOGETHER. INFILL WITH SUITE STANDARD CEILING TILES AT THIS LOCATION. PROVIDE NEN OFFICE LIGHT SNITCHES AT NEN OFFICE. RECIRCUIT LIGHTS AS REQUIRED. CONFIRM SNITCH LOCATION NIT NEN PROPOSED DOOR LOCATION. NA STATE ENERGY REQ. ALL FIXTURES ARE SCHEDULED TO REMAIN, BE RELOCATED OR BE DEMOLISHED. NO NEN WATTAGE IS TO BE ADDED TO 1-1-115 SUITE. CD1 NEW CONFERENCE 514 REVIEW FOR CODE COMPLIANCE OCT 092013 City of Tukwila BUILDING DIVISION EXISTING OFFICE bi3--)st7 RECEIVED CITY OF TUKWILA SEP 2 0 2013 PERMIT CENTER ••••• III ■ 111 IIT LEGACY PARTNERS CDS INC. Architecture and Interior Design 1660 Wynkoop Street, Suite 1120 Denver, CO 80202 Tel. (720) 932-3300 / Fax. (720) 932-3303 www.legacypartners.com/CDS Approval: TENANTS APPROVAL: Construction Documents THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE LEGACY PARTNERS, CDS INC. NORTHERN CALIFORNIA, AND ARE NOT TO BE REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION BY AN APPROPRIATE MEMBER OF THE CORPORATION. No. Issue or Revisions Dote LEGACY SOUTHCENTER PARKWAY 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 -- ;< -- ;< -- Stamp: 9941 REGISTERED CHITECT S METTLER STATE OF WASHINGTON Date: 09.13.13 Drawn by: MM Checked by: SM Drawing Title: REFL EC TED CEILING PLAN Scale: AS NOTED Project No: Drawing No: A22 / CROSS RUNNERS @ 2'-0" 0,C. DIAGRA"MATIC FRA 'U\ G PLA\ 2 CEILI G LEGEND: 0 OR 0 EXISTING 2'x4' T -BAR SUSPENDED CEILING GRID WITH SUITE STANDARD ACOUSTICAL CEILING TILES SPEC: MATCH EXISTING EXISTING 2X4 LENSED FLUORESCENT FIXTURE R RELOCATED 2X4 LENSED FLUORESCENT FIXTURE RECESSED CAN LIGHT FIXTURE RELOCATED CAN LIGHT FIXTURE EXISTING SPRINKLER LOCATION, FOR REFERENCE ONLY. BLDG. STANDARD EXIT SIGN LIGHT SWITCH EMERGENCY LIGHTING R = RELOCATED N = NEW REFLECTED CEILING NOTES: 1. THESE DESIGN DRAWINGS INDICATE TYPE AND LOCATION OF LIGHT FIXTURES. SNITCHING AND CIRCUITING SHALL BE DESCRIBED ON ENGINEER'S ELECTRICAL DRAWINGS, AND INSTALLED AS DIRECTED THEREIN. 2. ALL SNITCHING SHOWN SHALL BE 44" A.F.F. TO CENTERLINE OF COVERPLATE. MULTIPLE SWITCHES SHOWN AT THE SAME LOCATION SHALL BE GANGED AND FINISHED WITH A ONE PIECE COVERPLATE. ALL SWITCHES TO HAVE WHITE COVERPLATES. 3. VERIFY THAT ALL EXISTING LIGHT FIXTURES, TUBES, BALLASTS, EXIT LIGHTS, BATTERY PACK BACK-UPS, ETC. ARE OPERATIONAL. REPAIR/REPLACE AS REQUIRED N/ COOL WHITE BULBS. CLEAN LIGHT LENSES THROUGHOUT. 4. FIRE SPRINKLER CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS OF SPRINKLER LOCATIONS. ADD AND/OR RELOCATE SPRINKLER HEADS AS REQUIRED TO ACCOMMODATE NEN LAYOUT. 5. INSTALL SMOKE DETECTORS IN EXISTING AND NEN MECHANICAL UNITS AS REQUIRED BY CODE. 6. ALL EXISTING AND NEN DEVICES AND COVERPLATES TO MATCH EXISTING. 7. CLEAN/ REPAIR OR PAINT EXISTING CEILING GRID AND TILE FOR LIKE -NEN APPEARANCE. 8. VERIFY THAT ALL EXIT SIGNS COMPLY WITH THE BUILDING STANDARD NHITE SIGNS. INSTALL NEN AS NEEDED. CLEAN/ REPAIR EXISTING SIGNS FOR LIKE -NEN APPEARANCE. 9. REPAIR OR REPLACE NON-FUNCTIONING LIGHT FIXTURES. 10. CONTRACTOR SHALL PROVIDE EGRESS ILLUMINATION PER IBC 2009. CONTRACTOR IS RESPONSIBLE FOR DESIGN OF THE SYSTEM UNDER THE DESIGN BUILD CONTRACT. VERIFY WITH BUILDING MANAGEMENT AND PROVIDE FULL COMPLIANCE TO THE NEN SPACE Il. REVIEW ALL FIRE LIFE SAFETY EQUIPMENT LOCATIONS (INCLUDING BUT NOT LIMITED TO HORNS, STROBES) WITH DESIGNER PRIOR TO INSTALLATION. EXISTING OFFICE 520 SERVE OFFIC EXISTING OFFICE 504 EXISTING OFFICE EXISTING OFFICE Erna' 1111 501 � 1112.1.72 111111MINEAMINE IMW\/ EXISTING OFFICE EXISTING OFFICE WORK RCOM OPEN * 57fi REFLECTED C=ILI\ SCALE: 1/8"=1'-O" EXISTING OFFICE 508 EXISTING OFFICE EXISTING OFFICE .516 G PLA\ EXISTING OFFICE 509 NEW OFFICE 510 NEW OFFICE 511 NEW OFFICE 512 NEW OFFICE 513 KEYED REFLECTED CEILI \G NOTES REWORK SUITE SNITCHING AS REQUIRED FOR NEN SUITE EXPANSION LAYOUT. ALL OPEN AREA LIGHTING SHALL BE SNITCHED TOGETHER. INFILL WITH SUITE STANDARD CEILING TILES AT THIS LOCATION. PROVIDE NEN OFFICE LIGHT SNITCHES AT NEN OFFICE. RECIRCUIT LIGHTS AS REQUIRED. CONFIRM SNITCH LOCATION NIT NEN PROPOSED DOOR LOCATION. NA STATE ENERGY REQ. ALL FIXTURES ARE SCHEDULED TO REMAIN, BE RELOCATED OR BE DEMOLISHED. NO NEN WATTAGE IS TO BE ADDED TO 1-1-115 SUITE. CD1 NEW CONFERENCE 514 REVIEW FOR CODE COMPLIANCE OCT 092013 City of Tukwila BUILDING DIVISION EXISTING OFFICE bi3--)st7 RECEIVED CITY OF TUKWILA SEP 2 0 2013 PERMIT CENTER ••••• III ■ 111 IIT LEGACY PARTNERS CDS INC. Architecture and Interior Design 1660 Wynkoop Street, Suite 1120 Denver, CO 80202 Tel. (720) 932-3300 / Fax. (720) 932-3303 www.legacypartners.com/CDS Approval: TENANTS APPROVAL: Construction Documents THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE LEGACY PARTNERS, CDS INC. NORTHERN CALIFORNIA, AND ARE NOT TO BE REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION BY AN APPROPRIATE MEMBER OF THE CORPORATION. No. Issue or Revisions Dote LEGACY SOUTHCENTER PARKWAY 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 Stamp: 9941 REGISTERED CHITECT S METTLER STATE OF WASHINGTON Date: 09.13.13 Drawn by: MM Checked by: SM Drawing Title: REFL EC TED CEILING PLAN Scale: AS NOTED Project No: Drawing No: A22 ELECTRICAL LEGE\D Q CDC DUPLEX RECEPTACLE FOUR-PLEX RECEPTACLE DEDICATED DUPLEX RECEPTACLE SPECIAL RECEPTACLE DEDICATED FOUR-PLEX RECEPTACLE VOICE/DATA JACK FLOOR MOUNTED DUPLEX AND VOICE/DATA MUDRING WITH PULLSTRINGS BLANK PLATE SYSTEMS FURNITURE POWER POLE AS REQUIRED, COORDINATE WITH TENANTS FURNITURE VENDOR INDICATES NEN GENERAL NOTES 1. REFER TO PROJECT NOTES FOR CONSTRUCTION REQUIREMENTS. 2. ELECTRICAL SUB -CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE WORKING CONDITION OF ALL EXISTING OUTLETS NOTED TO REMAIN. 3. ALL OUTLETS SHOWN ARE APPROXIMATE. DUE TO HIDDEN CONDITIONS ADDITIONAL P/P/D MAY EXIST BUT NOT BE REFLECTED ON THE PLANS. 4. FURNITURE SHOWN FOR INTENT ONLY, FINAL LOCATION OF FURNITURE AND OUTLETS TO BE COORDINATED WITH TENANTS FURNITURE VENDOR. 5. ALL COVERPLATES AND DEVICES SHALL BE WHITE. UPDATE EXISTING PLATES AND OUTLETS AS PEQUIRED. KEY \OTES O COORDINATE FINAL INSTALLATION LOCATION WITH TENANT AND TENANTS FURNITURE. VERIFY POWER REQUIREMENTS WITH TENANT PROVIDED WORKSTATIONS. OPROVIDE BLANK COVERPLATES AT UNUSED VOICE/DATA OUTLETS KEYED ALTER\ATE SHEET \OTES PROVIDE LINE ITEM PRICING AT EXISTING CORE DRILL LOCATION, PROVIDE FLUSH COVERPLATE. NEN OUTLETS AND V/D MUDRINGS WITH PULLSTRINGS SHALL BE MOUNTED AT CD 32" AFF (MATCHEXISTING). CONFIRM EXACT LAYOUT WITH TENANT. EQUIPME\T LIST 2 COPIER (BY TENANT, GC TO CONFIRM ALL POWER REQUIREMENTS) FAX MACHINES (BY TENANT) HALLWAY 523 0 A 0 OPEN OFFICE 524 Ji EXISTING OFFICE EXISTING OFFICE 504 +44 +72 0 +72 RECEPTIO 500 WORK ROOM 521 NEW CONFERENCE EXISTING OFFICE 506 EXISTING OFFICE 'Eff PREP co 503 CNIN ++ O HALLWAY 525 EXISTING OFFICE 517 EXISTING OFFICE 508 A\D DATA PLA SCALE: I/8=1 -0 EXISTING OFFICE 509 0 EXISTING OFFICE NEW OFFIC 510 NEW OFFICE 511 NEW OFFICE 512 NEW OFFICE 513 NEW CONFERENCE 514 REVIEWED FOR CODE PROVED CE AP OCT 09 2013 City of Tukwila BUILDING DIVISION EXISTING OFFICE EXISTING OFFICE 518 EXISTING OFFICE 520 3- )-9i7 RECEIVED CITY OF TUKWILA SEP 2 0 2013 PERMIT CENTER ..... IIIA 111 III ■ LEGACY PARTNERS CDS INC. Architecture and Interior Design 1660 Wynkoop Street, Suite 1120 Denver, CO 80202 Tel. (720) 932-3300 / Fax. (720) 932-3303 www.legacypartners.com/CDS Approval: TENANTS APPROVAL: Construction Documents THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE LEGACY PARTNERS, CDS INC. NORTHERN CALIFORNIA, AND ARE NOT TO BE REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION BY AN APPROPRIATE MEMBER OF THE CORPORATION. No. Issue or Revisions Date LEGACY SOUTHCENTER PARKWAY 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 Stamp: 9941 REGISTERED ARCHITECT drier SHAFTTLER STAT OF WASHINGTON q AO. 3 Date: 09.13.13 Drawn by: MM Checked by: SM Drawing Title: PO V/ER/DATA PLAN Scale: AS NOTED Project No: Drawing No: A20 i ••••• 111 111.■ 111 ■ LEGACY PARTNERS CDS INC. Architecture and Interior Design 1660 Wynkoop Street, Suite 1120 Denver, CO 80202 Tel. (720) 932-3300 / Fax. (720) 932-3303 www.legacypartners.coni/CDS Approval: • 4 d •° V STRUCTURAL DECK ABOVE 4STL. STUD BRACE @ 6'-0" MAX SECURED TO STRUCURE ABOVE No. Issue or Revisions Date s LEGACY SOUTHCENTER PARKWAY 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 CEILING LINE 5/5" TYPE "X" CONT. 25 GA. METAL GYPSUM BOARD 2-1/2" 25 GA. MTL. ) : Date: 09.13.13 STUD RUNNER TOP AND BOTTOM STUD AT 24" 0.0. Drawing Title: WALL TYPES/ DETAILS Scale: AS NOTED Project No: 411 VINYL BASE POWDER DRIVEN FASTENER @ 24" OC d STA\DARD I\TERIOR PARTITION SCALE: I" = IL -0" 4'-0" 4'-0" ipiplpipipeolo _AL_ _AL_ A._ ,AL, } Aii_ ,41._ _AL_ Iii 6" X 5' X FULL LENGTI-1STL. BATT INSULATION CEILING LINE `, WI STUD BRACE @ 6'-0" MAX SECURED TO STRUCURE ABOVE LL ALL VOIDS N/ BATT INSUL. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2013 CI Of Tukwila BUILDING DIVISION 5/5"PTYPE "X") ` IW CONT. 25 GA. METAL GYPSUM BOARD 2-1/2" 25 GA. MTL. r. I `411 STUD RUNNER TOP AND BOTTOM STUD AT 24 O,C. I • .VI I I"A 4" VINYL BASE PONDER DRIVEN FASTENER @ 24" OC °• I\SULATED SOU\D PARTITIO\ SCALE: 1" = 11-0" 2 L J C EXISTING MULLION BELOW LINE OF SILL DOUBLE SIDED FOAM TAPE DOUBLE STUDS PARTITION AS SCHEDULED SEE PLAN FOR TYPE AALL TO h1ULLIO\ DETAIL SCALE: 3" = 1'-0" 3 b ye -5...„ 4 „ 07. 0 0 , .q 7 RECEIVED CITY OF TUKWILA SEP 2 0 2013 PERMIT CENTER ••••• 111 111.■ 111 ■ LEGACY PARTNERS CDS INC. Architecture and Interior Design 1660 Wynkoop Street, Suite 1120 Denver, CO 80202 Tel. (720) 932-3300 / Fax. (720) 932-3303 www.legacypartners.coni/CDS Approval: TENANTS APPROVAL: Construction Documents THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY OF THE LEGACY PARTNERS, CDS INC. NORTHERN CALIFORNIA, AND ARE NOT TO BE REPRODUCED OR DISTRIBUTED IN WHOLE OR IN PART WITHOUT THE WRITTEN AUTHORIZATION BY AN APPROPRIATE MEMBER OF THE CORPORATION. No. Issue or Revisions Date s LEGACY SOUTHCENTER PARKWAY 16400 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 Stamp: 9941 REGISTERED ARCHITECT S ETTLER STATE OF WASHINGTON q /2/6 Date: 09.13.13 Drawn by: MM Checked by: SM Drawing Title: WALL TYPES/ DETAILS Scale: AS NOTED Project No: Drawing No: A6,,1