Loading...
HomeMy WebLinkAboutPermit D13-303 - WASHINGTON AUDIOLOGY - TENANT IMPROVEMENTWASHINGTON AUDIOLOGY 635 ANDOVER PK W D13-303 City oilii'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 2623049143 Address: 635 ANDOVER PK W TUKW Suite No: Project Name: WASHINGTON AUDIOLOGY DEVELOPMENT PERMIT Permit Number: D13-303 Issue Date: 10/10/2013 Permit Expires On: 04/08/2014 Owner: Name: SOUTHCENTER CORPORATE SQUARE Address: 150 CALIFORNIA ST , SAN FRANCISCO CA 94111 Contact Person: Name: SHANNON MILLER Address: 635 ANDOVER PK W, SUITE 107 , TUKWILA WA 98188 Contractor: Name: DAVIS SCHUELLER INC. Address: 20700 44 AV W STE 280 , LYNNWOOD, WA 98036 Contractor License No: DAVISSI105PN Lender: Name: Address: Phone: 206-575-3080 Phone: 206 775-9400 Expiration Date: 07/01/2014 DESCRIPTION OF WORK: NEW TENANT: TENANT IMPROVEMENT TO THE 1ST FLOOR SUITES FOR OFFICE USE TO INCLUDE THE DEMOLITION OF EXISTING PARTITIONS AS WELL AS ADDITION OF NEW PARTITIONS, DOORS, RELITES AND NEW FEATURES. Value of Construction: $25,000.00 Fees Collected: $962.00 Type of Fire Protection: SPRINKLERS/AFA International Building Code Edition: 2012 Type of Construction: VB Occupancy per IBC: 0008 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-303 Printed: 10-10-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: N Number: 0 N Start Time: Volumes: Cut 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: N Permit Center Authorized Signature: Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. C'�'V v �n/�/j n Signature: ��" ,�V' 1V `-V/� ' i `� Date: 1 O 01 1 3 Print Name: 9AO1y law\ N, ►tel I SLet/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: New suspended ceiling grid and light fixture installations shall meet the non -building structures seismic design requirements of ASCE 7. 6: Partition walls that are tied to the ceiling and all partitions greater than 6 feet in height shall be laterally braced to the building structure. doc: IBC -7/10 D13-303 Printed: 10-10-2013 7: All construction shall be done in conform with the approved plans and the requirem of the International Building Code or International Residential C International Mechanical Code, Washingto�te Energy Code. 8: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ***FIRE DEPARTMENT CONDITIONS*** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 15: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 16: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 17: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 18: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 19: Egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. (IFC 1008.1.8.3 subsection 2.2) 20: Dead bolts are not allowed on auxiliary exit doors unless the dead bolt is automatically retracted when the door handle is engaged from inside the tenant space. (IFC Chapter 10) 21: Door handles, pulls, latches, locks and other operating devices on doors required to be accessible by Chapter 11 of the International Building Code shall not require tight grasping, tight pinching or twisting of the wrist to operate. (IFC 1008.1.8.1) 22: Exit hardware and marking shall meet the requirements of the International Fire Code. (IFC Chapter 10) 23: Exits and exit access doors shall be marked by an approved exit sign readily visible from any direction of egress travel. Access to exits shall be marked by readily visible exit signs in cases where the exit or the path of egress travel is not immediately visible to the occupants. Exit sign placement shall be such that no point in an exit access corridor is more than 100 feet (30,480 mm) or the listed viewing distance for the sign, whichever is less, from the nearest visible exit sign. (IFC 1011.1) 24: Every exit sign and directional exit sign shall have plainly legible letters not less than 6 inches (152 mm) high with the principal strokes of the letters not less than 0.75 inch (19.1 mm) wide. The word "EXIT" shall have letters having a width not less than 2 inches (51 mm) wide except the letter "I", and the minimum spacing between letters shall not be doc: IBC -7/10 D13-303 Printed: 10-10-2013 less than 0.375 inch (9.5 mm). Signs larger tha. e minimum established in section 1011.5.1 o International Fire Code shall have letter widths, strokes and spa in proportion to their height. The word "E all be in high contrast with the background and shall be clearly discernible when the exit sign illumination means is or is not energized. If an arrow is provided as part of the exit sign, the construction shall be such that the arrow direction cannot be readily changed. (IFC 1011.5.1) 25: Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or on-site generator. (IFC 1006.1, 1006.2, 1006.3) 26: Emergency lighting facilities shall be arranged to provide initial illumination that is at least an average of 1 foot-candle (11 lux) and a minimum at any point of 0.1 foot-candle (1 lux) measured along the path of egress at floor level. Illumination levels shall be permitted to decline to 0.6 foot-candle (6 lux) average and a minimum at any point of 0.06 foot-candle (0.6 lux) at the end of the emergency lighting time duration. A maximum -to -minimum illumination uniformity ratio of 40 to 1 shall not be exceeded. (IFC 1006.4) 27: Aisles leading to required exits shall be provided from all portions of the building and the required width of the aisles shall be unobstructed. (IFC 1013.4) 28: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) 29: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 30: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 31: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 32: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 33: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 34: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 35: The maximum flame spread class of finish materials used on interior walls and ceilings shall not exceed that set forth in Table No. 803.5 of the International Building Code. 36: In order to provide you with the fastest police and fire protection under emergency conditions, please post your suite, room or apartment number in a conspicuous place near the main entry door. (IFC 505.1) 37: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 38: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 39: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IBC -7/10 D13-303 Printed: 10-10-2013 CITY OF TUh WILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd , Suite 10(1 Tukwila, 01-1 98188 http://www.TukwilaWA.gov Building Permit No.] 13 .30 Project No. Date Application Accepted: ()y,/.) 7/13 Date Application Expires: 0347// • (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: t7"��� '1 n" c D v w ?011/ , jet Tenant Name: MC01°�Y NOI I OI VJ PROPERTY OWNER 1�,�r v/ �1 Name:�✓�UTt C`cl t e w� Qov to q�iciV€ Address: 4 1 0 ri vi"- -v cr. I (no 1 �S�ttate: w Zip:go.IOI City: Sett- le CONTACT PERSON - person receiving all project communication NameTAVYW61 UI O V) I X11 VII 11 0.1 I Q Address:u-,p,,n,.l,rvev pow W -10 1 �� Ikl t��GV City: -T` 1 ii, /t State: 1-' f\ _ Zip:rp-)„I/}Q ►(i' j)\ "1^t Fax: C.2, Phone:(V-0%�//jV (cf IW Email: SWI11 I Q./I/poi✓nY N *.fe ' IJ II �' 1 • ► l GENERAL CONTRACTOR INFORMATION', Company Name: Address: Address: WOO001 6 Ve- e I 1:FCity: geQ z State:I A._Zipq�D ItogPhone, __ C ` JJ`4-k I Fax: City: State: Zip: Phone: Fax: City: State: Contr Reg No.: Phone: Exp Date: Tukwila Business License No.: H:\Applications\Forms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-1 I.docs Revised: August 2011 bh King Co Assessor's Tax No.: 2k22- 2 04 011-3 Suite Number: 1004- (1 1 Floor: Sfi New Tenant: Yes C ..No ARCHITECT OF RECORD L��I,,,,..IA' Company Name:1tAc1V Y I y 1 sr tv , \svv�� ����-- Architect Name: -Ev:1 v GD0oI el ( Address: WOO001 6 Ve- e I 1:FCity: geQ z State:I A._Zipq�D ItogPhone, __ C ` JJ`4-k I Fax: Email: �DC VII 1@ U v tikil 1SKI n oo 1 ENGINEER OF RECORD Company Name: Engineer Name: Address: City: State: Zip: Phone: Fax: Email: LENDER/BOND.ISSUED; (required for projects $5,000 or greater per RCV✓ 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 • • BUILDING PERMIT INFORMATION —206-431-3670 Valuation of Project (contractor's bid price): $ 4'2,O' 4/7/V)11:P 0 Describe the scope of work (please provide detailed information): Existing Building Valuation: $ \00, 000 -t.Wciv t '1 Y pvov eWnr,(2v►t -to-tune lsfi-fioov s6 s --fo✓ c Ice. uS-t �-o-Ivndual e -11A -e donnatieh Q)6sti rn Ovns 7,4 ci cI t -t10 vl DE v-evki mv-htions, d oovs,vecties v w4Cc -f- . Will there be new rack storage? ❑ Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing. Interior Remodel" Addition to Existing Structure, New Type of Construction per 1BC Type of Occupancy per IBC '151 Floor 441 -to‘l- e o4 - Ino e ribvT V 1� 2nd Floor 3rd Floor is Floors `' ` " thin Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck" Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? 0 Yes No If"yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: .f Sprinklers .;71.. Automatic Fire Alarm ❑ None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If 'yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 0-9-I I.docc Revised: August 2011 bh Page 2 of 4 PUBLIC WORKS PERMIT INFORMATION — 206-433-0179 Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. ter District ..Tukwila ❑ ... Water District #125 ❑ ...Water Availability Provided Se r District ...Tukwila ❑... Valley View ❑ .. Renton ❑ ...Sewer Use Certificate 12 ... Sewer Availability Provided 0 .. Highline 0 .. Renton ❑ .. Seattle Septic System: O On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): 0 ...Civil Plans (Maximum Paper Size — 22" x 34") ❑ ...Technical Information Report (Storm Drainage) ❑ ...Bond 0 .. Insurance 0 .. Easement(s) Proposed Activities (mark boxes that apply): ❑ ...Right-of-way Use - Nonprofit for less than 72 hours ❑ ...Right-of-way Use - No Disturbance ❑ ...Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ ...Total Cut ❑ ...Total Fill cubic yards cubic yards ❑ .. Geotechnical Report O .. Maintenance Agreement(s) 0 ...Traffic Impact Analysis 0 ...Hold Harmless — (SAO) ❑ ...Hold Harmless — (ROW) ❑ .. Right-of-way Use - Profit for less than 72 hours ❑ .. Right-of-way Use — Potential Disturbance ❑ .. Work in Flood Zone ❑ .. Storm Drainage 0 ...Sanitary Side Sewer 0 .. Abandon Septic Tank 0 .. Grease Interceptor ❑ ...Cap or Remove Utilities 0 .. Curb Cut 0 .. Channelization 0 ...Frontage Improvements 0 .. Pavement Cut ❑ .. Trench Excavation ❑ ...Traffic Control 0 .. Looped Fire Line ❑ .. Utility Undergrounding ❑ ...Backflow Prevention - Fire Protection Irrigation Domestic Water ❑ ...Permanent Water Meter Size... WO # 0 ...Temporary Water Meter Size .. WO # ❑ ...Water Only Meter Size WO # 0 ...Deduct Water Meter Size O ...Sewer Main Extension Public 0 Private 0 O ...Water Main Extension Public 0 Private ❑ FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ ...Water ❑ ...Sewer ❑ ...Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-11.docx Revised: August 2011 bh Page 3 of 4 PERMIT APPLICATION NOTES - Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED GENT:, Signature: ` Date. Print Name: 500 V ' O 1\1' 1" t\ WA/ Day Telephone: (20 ) S7t ~ wz,O Mailing Address: �' '"� Mai ai OvQv poi VK vv -e6-1- 4- Iq --it/P/1;111 viI I arc iW City State Zip H:\Applications\Forms-Applications On Line\2011 Applications\Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Page 4 of 4 1 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.Qov Parcel No.: 2623049143 Address: 635 ANDOVER PK W TUKW Suite No: Applicant: WASHINGTON AUDIOLOGY RECEIPT Permit Number: D13-303 Status: PENDING Applied Date: 09/27/2013 Issue Date: Receipt No.: R13-02752 Initials: User ID: LAW 1632 Payment Amount: $962.00 Payment Date: 09/27/2013 11:28 AM Balance: $0.00 Payee: SOUTHCENTER CORP SQUARE LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 5241 962.00 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $962.00 580.30 377.20 4.50 Printed• n1-77-7013 INSPECTION NO. INSPECTION RECORD Retain a copy with permit 13 '3 Q- PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro'e ti A Au .�1.aC� � Typ of I ,spectiotZ bu * % , N& AiA L Add ess- 1x035 NNO over- v.1 Date Iled: Gf ?._j /t G Special Instructions: '� Date Wanted: `a.m. 11 - / Z -- /3 p:m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: n2ltit;Tco n.,� Insp ctor: Date / '. n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: W i'N t* ► TG 3 AI li.1C Type of Inspection: 1 L c1 Ev'i JJCci k4i+.N Address: 35 A ki 6cJW R P lz (i...)r Date Called: Z IN/C..,IN/C..,(o Special Instructions: 'j 1111 Date Waned: H14 -t-1 -3 m: C,,n,_ Requester: Phone No: ,gb6—S71 —I 0 31 Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ins ector: 1/ d IL -0.N1! Date: r� I l• n REINS E TION FEE REQUIRED. Prior to next inspection. fe(must be paid at�¢3, 0 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit ' 3 �3 03 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter BIvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 P o'e WiA ii 14b t 0 La 6 y Typc..of Inspection: tr-AA,Ab Add ess- . .5' A OV er w Date Called: �-.- Special Instructions: II ' ar F4on Date Wanted: I0 �r' —%3 p.m. Requester: l Approved per applicable codes. LJ Corrections required prior:toaapproval. COMMENTS:. c90uv 1 Inspector: REINSPECTION FEE REQUIRED. or to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Datg: INSPECTION NUMBER INSPECTION RECORD Reta n a copy with permit DI3- 303 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 0A Av.d ( 0 1 c) s---u'S S Fire Alarm: Ty e of I spection: ,. - I A -F f -- Address: Suite #: / Permits: Contact Person: Special Instructions:ti Phone No.: 'Approved per applicable codes. Corrections required prior to approval. COMMENTS: C(puhet - (),C Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: // C ., Se- Date: //// 7A5 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 ? 206-575-4407 Project: MIA �(() 67 Sprinklers: Typein�s-pection: '7 ,GV A L - Address: 63.5"" Suite #: Pre -Fire: h/ Contact Person: Special Instruc ions: 1 Phone No.: RApproved per applicable codes. Corrections required prior to approval. COMMENTS: SP -C-kx \kL -- 0 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 66., 5---L____ Date: / /.. /0/3 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: Cite State: Zip: Word/Inspection Record Form.Doc-.=. '6/11/10 T.F.D. Form F.P. 113 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 3-9 2`t£s PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: W A 44 & aQ i vu. -4 Type of Inspection: SP — Ca, Vel' Address: ', 3-- - A PVA Suite #: `Ip- 7 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Ole, -6 v a-tr- Needs Shift Inspection: Sprinklers: Fire Alarm: . Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: z "4`3 Date: / e/ Z y// 3 Hrs.: f $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection: Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection. Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 PERMIT COORD COPY.� PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-303 DATE: 09/27/13 PROJECT NAME: WASHINGTON AUDIOLOGY SITE ADDRESS: 635 ANDOVER PK W X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division 37167 t9 11' Public Works Fire Prevention Structural mip f11 ®� Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10/01/13 Complete Nt Incomplete Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route )4 Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DUE DATE: 10/29/13 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Per Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name DAVIS SCHUELLER INC UBI No. 601273797 Phone 4257759400 Status Active Address 20700 44Th Ave W Ste 280 License No. DAVISSI105PN Suite/Apt. License Type Construction Contractor City Lynnwood Effective Date 10/15/1990 State WA Expiration Date 7/1/2014 Zip 98036 Suspend Date County Snohomish Specialty 1 General Business Type Corporation Specialty 2 Unused 0j:5( Parent Company o'\°\°4 icenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status RSMANI'011BN R 5 MANUFACTURING INC Construction Contractor Cabinets, Millwork And Finish Carpentry Unused 1/15/1999 3/3/2015 Active DAKOTWC962BH DAKOTA WIRELESS CONST SVCS LLC Construction Contractor General Unused 1/8/2004 1/8/2006 Archived SILVECI988Q0 SILVERCREEK CONSTRUCTION INC Construction Contractor General Unused 11/20/2002 11/20/2004 Archived SEACRMI104DE SEACREST MFG INC Construction Contractor Cabinet And Millwork Carpentry/Framing 3/5/1990 2/26/1999 Archived OLYMPE*121QA OLYMPIC ENTERPRISES Construction Contractor General Unused 11/1/1988 11/1/1989 Archived DALFOCI1810E DALFORD COMPANY INC, THE Construction Contractor General Unused 2/5/1982 12/26/1991 Archived DALFOC'198LW DALFORD COMPANY, THE Construction Contractor General Unused 6/16/1981 6/1/1982 Archived Business Owner Information Name Role Effective Date Expiration Date DAVIS, BILL E President 01/15/1990 SCHUELLER, DANETTE Secretary 01/15/1990 DAVIS, BARBARA D Treasurer 01/15/1990 SCHUELLER, KENNETH E Vice President 01/15/1990 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 CBIC SF2518 10/15/2003 Until Cancelled $12,000.00 10/31/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 20 AMERICAN FIRE & CASUALTY CO BKA53228151 07/01/2010 07/01/2014 $1,000,000.00 06/19/2013 httns://fortress.wa. aov/lni/bbip/Print. aspx 10/10/2013 U 00 U F - (f) •3 0 Cn `o T 0 0 0 1E cn co c N �o •fir) 325I L o _j CIO c I o ov N V) EXISTING STRUCTURE METAL CLIP METAL STUDS STAGGERED @ 8'-0" 0.0. FOR ALL UNBRACED STRAIGHT RUNS OF WALL OVER 12'-0". ATTACH TO STRUCTURE ABOVE. (2) #10 SCREWS SCHEDULED CEILING TILE & GRID 8' MAX 8' MAX 8' MAX 8' MAX 8' MAX OMIT BRACING AT WALL LATERAL BRACING (STAGGERED) PER DETAIL ABOVE (TYP.) LATERAL WALL BRACING PLAN VIEW NTS 8'MAX2'MAX k�TO END I , OF WALL TOP OF WALL NOTES: 1. LATERAL BRACING IS TO BE INSTALLED ON TENANT PARTITIONS AT 8 FEET O.C. EXCEPT AT INTERSECTIONS WITH WALLS AT LEAST 4 FEET LONG. (PER TYPICAL PARTITION PLAN) 2. PROVIDE BRACING AT ANY PERMANENT PARTITION THAT IS NOT ATTACHED TO CEILING GRID. STANDARD HEAD BRACING 1/8" DIA. X 3" CONCRETE EYE SCREW TO STRUCTURE (NO DRIVE PIN CONNECTION). VERTICAL WIRE HANGER -NO. 12 GAUGE @ 4'-0" 0.0. OR NO. 10 GAUGE @ 5'-0" O.C. ALONG EACH MAIN RUNNER. HEAVY GAUGE WIRE "PIN". VERTICAL STRUT STABLING BAR @ 12'-0" EACH DIRECTION FASTENED TO MAIN RUNNER AND CUT TIGHT TO STRUCTURE ABOVE, HELD IN PLACE BY VERTICAL WIRE HANGER AND HEAVY GAUGE WIRE PIN. HEAVY DUTY MAIN RUNNER AT 4'-0" O.C. (4) LATERAL SUPPORT WIRES AS NOTED (BELOW). VERTICAL STRUT FASTENED TO MAIN RUNNER. CROSS RUNNER SUSPENDED CEILINGS ARE TO COMPLY WITH FOLLOWING CODES AND REGULATIONS: A. B. 2012 INTERNATIONAL BUILDING CODE (IBC) SECTIONS 803.9 AND 1613.1. PARTIAL LISTING OF REQUIREMENTS FOR SUSPENDED CEILINGS: 1. A HEAVY DUTY T -BAR GRID SYSTEM. 2. PERIMETER CLOSURE ANGLE (WALL ANGLE) SHALL BE NOT LESS THAN 2.0 INCHES. 3. ON TWO ADJACENT SIDES, THE GRID SHALL BE ATTACHED TO THE WALL (ANGLE POP RIVETS ARE ACCEPTABLE). THE OTHER TWO SIDES, SHALL HAVE 3/4 INCH CLEARANCE BETWEEN THE ENDS OF THE GRID AND THE WALL. 4. STABILIZER BARS ARE REQUIRED TO PREVENT THE SPREAD OF MAIN BEAMS AND/OR CROSS TEES. 5. PERIMETER SUPPORT (TAIL) WIRES ARE REQUIRED WITHIN EIGHT INCHES OF THE WALL FOR ALL EDGES. 6. VERTICAL HANGERS SHALL BE NO. 12 GAUGE WIRE SPACED AT 4 FEET ON CENTER OR NO. 10 GAUGE SPACED AT 5 FEET ON CENTER ALONG EACH MAIN RUNNER. THREE WIRE TURNS REQUIRED. WITHIN 1:6 OUT -OF -PLUMB UNLESS COUNTER -SLOPING WIRES ARE PROVIDED. 7. LATERAL BRACING IS REQUIRED. SPLAY WIRE PODS AT 12' MAX. O.C. AND 6' MAX. FROM WALLS. A STRUT FASTENED TO THE MAIN RUNNER SHALL BE EXTENDED TO AND FASTENED TO STRUCTURE 8. CEILINGS OVER 2,500 SQUARE FEET MUST HAVE SEISMIC SEPARATION JOINTS OR FULL HEIGHT PARTITION THAT BREAKS THE CEILING UP INTO AREAS NOT EXCEEDING 2,500 SQUARE FEET. 9. FOR CEILINGS WITHOUT RIGID BRACING, SPRINKLER HEAD AND OTHER PENETRATIONS SHALL HAVE A 2 -INCH OVERSIZE RING, SLEEVE, OR ADAPTER THROUGH THE CEILING TILE TO ALLOW FOR FREE MOVEMENT OF AT LEAST 1 -INCH IN ALL HORIZONTAL DIRECTIONS; OR, SPRINKLER HEAD EXTENSION TO HAVE A SWING JOINT THAT CAN ACCOMMODATE 1 INCH OF CEILING MOVEMENT IN ALL HORIZONTAL DIRECTIONS. 10. CHANGES IN CEILING PLAN ELEVATION SHALL BE PROVIDED WITH POSITIVE BRACING. 11. CABLE TRAYS AND ELECTRICAL CONDUITS SHALL BE SUPPORTED INDEPENDENTLY OF THE CEILING. 12. ALL WIRE TIES TO BE THREE TIGHT TURNS AROUND ITSELF WITHIN THREE INCHES. TWELVE GAUGE HANGER WIRES SPACED 4' O.C. 635 ANDOVER PARK W EXISTING (2) STORY BUILDING NO CHANGE IN BUILDING AREA NO STRUCTURAL WORK NO EXTERIOR WORK NO CHANGE IN USE / OCCUPANCY soar NO $352 5£22x 5222 252 £225 MK 5,22 5£53 2222£ AREA OF WORK SUITE 100 LONGEST COMMON PATH OF EGRESS TRAVEL : 30' - 1" EGRESS TRAVEL INFORMATION COMMON PATH OF EGRESS TRAVEL (SPRINKLERED) MAXIMUM DISTANCE = 100' (PER SECTION 1014.3) TRAVEL DISTANCE (SPRINKLERED) MAXIMUM DISTANCE = 300' (PER TABLE 1016.2) OCCUPANT LOAD CALCULATION OFFICE SQUARE FOOTAGE: 334 SQ. FT. (1:100 PER TABLE 1004.1.2) TOTAL OCCUPANTS ALLOWED = 4 OCCUPANTS (1) EXIT(S) REQUIRED PER TABLE 1015.1; (1) EXIT(S) PROVIDED LONGEST COMMON PATH OF EGRESS TRAVEL : 32' - 11" AREA OF WORK SUITE 111 EGRESS TRAVEL INFORMATION COMMON PATH OF EGRESS TRAVEL (SPRINKLERED) MAXIMUM DISTANCE =100' (PER SECTION 1014.3) TRAVEL DISTANCE (SPRINKLERED) MAXIMUM DISTANCE = 300' (PER TABLE 1016.2) OCCUPANT LOAD CALCULATION OFFICE SQUARE FOOTAGE: 3,232 SQ. FT. (1:100 PER TABLE 1004.1.2) TOTAL OCCUPANTS ALLOWED = 33 OCCUPANTS ri (1) EXIT(S) REQUIRED PER TABLE 1015.1; (2) EXIT(S) PROVIDED NORTH BLDG 8 2 MINKLER BLVD. ANDOVER PARK W. NORTH SITE PLAN NTS 14‘r - A SOUTHCENTER P r STRANDER BLVD. w 0 0 MINK R E LVD. UPLAND DR. MIDLAND D . TRILAND DR. SITE NORTH 3 KEY PLAN. EXITING AND OCCUPANCY LOAD CALCULATION NTS 4 VICINITY PLAN NTS CEILING SUPPORT DATA 4'-0" WIDE ACOUSTIC BATT INSULATION CENTERED OVER PARTITION ABOVE HUNG CEILING. 1/4" NON-COMBUSTABLE WOOD FILLER UNDER MAIN RUNNERS. CEILING 9 + 8'-8" A.F.F. (WHERE INDICATED ON REFLECTED CEILING PLAN). CONTINUOUS 'L' METAL TRIM W/ PAPER WING (BOTH SIDES OF PARTITION) ACOUSTIC BATT INSULATION . GALV. STEEL SILL TRACK. ATTACH TO STRUCTURE WITH HILTI X -U (OR XU15) UNIVERSAL KNURLED SHANK POWDER DRIVEN FASTENER WITH MIN. 1" EMBEDMENT @ 16" O.C. (FOLLOW MANUFACTURER'S INSTRUCTIONS). FLOORING AS SCHEDULED (BOTH SIDES OF PARTITION) SEISMIC BRACING (BEYOND) PER 1/TI-1. STUD SCHEDULE STUD SCHEDULE: 2-1/2" = 250S125-27 (22 GA); MAX 18'-0" HIGH. NOTES: 1. ALL STUDS ARE AT 16" 0.C. 2. USE SAME GAUGE AS STUDS FOR TRACKS AND CHANNEL. 3. USE SSMA TECHNICAL GUIDES. ( 1/8" BLACK FOAM TAPE, HOLD BACK 1/4" FROM EDGE OF TRACK (BOTH SIDES) METAL TRACK WITH (2) #10 SCREWS AT 16" O.C. REVEAL (PAINT BLACK) OR MATCH EXISTING CONDITION. (BOTH SIDES OF PARTITION) 5/8" FIRE RETARDANT TREATED PLYWOOD BLOCKING AT WALL HUNG ITEMS (WHERE APPLICABLE- REFER TO DRAWING PLANS). ALTERNATE FOR BLOCKING: 20" WIDE SHEET METAL AT +40" FROM FLOOR TO BOTTOM (IN LIEU OF WOOD BLOCKING) 5/8" GWB, TYPE 'X' EACH SIDE BASE, AS SCHEDULED. (BOTH SIDES OF PARTITION.) EXISTING STRUCTURE (BELOW) GALV STEEL STUD, PER STUD SCHEDULE, WITH 5/8" TYPE 'X' GWB EACH SIDE. STANDARD TENANT PARTITION 4� 4 STAIR 0 f N.I.C. /7 f/ / DESIGNATED EGRESS PATH (HATCHED AREA) co 01 ci CB O Ezi 0 IT OD /./ 0 5'-2" E T /„: IT NOTE: MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. NEW OR RELOCATED B/S 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. E . ISTING 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. PLANNING APPROVE., No changes Can be made to these plans without approval from the Planning Division of DCD Approved B Date: UP NORTH ACT ADJ AFF ALT ALUM APPROX BLDG BLKG B/S CAB CLR CLG CL COL COMM COMP CONST CONT CPT CT DIA DIM DR DW DWG E EA ELEC ELEC'L ELEV EXIST EXT FIN FLR FLUOR FMC FR FT FURN GA GALV GD GL GWB HC HDW HM HT HVAC IN INCL INSUL INT ACOUSTICAL CEILING TILE ADJACENT / ADJUSTABLE ABOVE FINISH FLOOR ALTERNATE ALUMINUM APPROXIMATELY AT BUILDING BLOCKING BUILDING STANDARD CABINET CLEAR/CLEARANCE CEILING CENTERLINE COLUMN COMMUNICATION COMPOSITION CONSTRUCTION CONTINUOUS CARPET CERAMIC/CONCRETE TILE DIAMETER DIMENSION DOOR DISHWASHER DRAWING EXISTING / EAST EACH ELECTRIC ELECTRICAL ELEVATION (VIEW) EXISTING EXTERIOR FINISH FLOOR FLUORESCENT FLOOR MATERIAL CHANGE FIRE RATED FEET FURNISH / FURNISHINGS GAUGE GALVANIZED GARBAGE DISPOSAL GLASS / GLAZING GYPSUM WALL BOARD HOLLOW CORE HARDWARE HOLLOW METAL HEIGHT HEATING, VENTILATING, AIR CONDITIONING INCH INCLUDE INSULATION INTERIOR JT LL@TE LF MAX MECH MFR MIN MISC MTD MTL MW N/A NIC NO NOM NTS OC OPNG OPP ORIG PERM PL PLAM PLYWD PR PTN R RB REF REINF REQ'D REV RM RO S SCHED SC SECT SIM SPEC SQ STD STL STOR SUSP TEL TSG TYP VCT VERT W/ W/0 WC WD JOINT BY LANDLORD AT TENANT'S EXPENSE LINEAL FOOT MAXIMUM MECHANICAL MANUFACTURER MINIMUM MISCELLANEOUS MOUNTED METAL MICROWAVE OVEN NORTH / NEW NOT APPLICABLE NOT IN CONTRACT NUMBER NOMINAL NOT TO SCALE ON CENTER OPENING OPPOSITE ORIGINAL PERMANENT PLATE PLASTIC LAMINATE PLYWOOD PAIR PARTITION RADIUS / REMOVE / RELOCATE, RUBBER BASE REFRIGERATOR REINFORCING REQUIRED REVISION / REVERSE ROOM ROUGH OPENING SOUTH SCHEDULE SOLID CORE SECTION SIMILAR SPECIFICATION SQUARE STANDARD STEEL STORAGE SUSPENDED TELEPHONE TEMPERED SAFETY GLASS TYPICAL VINYL COMPOSITION TILE VERTICAL WEST WITH WITHOUT WALLCOVERING WOOD EGRESS PLAN NTS ABBREVIATIONS NA NOT USED NA SEPARATE PERMIT REQUIRED FOR: 11) Mechanical Electrical Plumbing tt Gas Piping City of Tukwila BUILDING DIVISION NOT USED NA SHEET INDEX TI -1 COVER SHEET TI -2 DEMOLITION & CONSTRUCTION PLANS TI -3 REFLECTED CEILING & ELECTRICAL PLANS REVISIONS No ctt ages shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 10 I SHEET INDEX NA SCOPE OF WORK TENANT IMPROVEMENT TO EXISTING SUITES 100 AND 111 ON THE FIRST FLOOR OF AN EXISTING OFFICE BUILDING TO INCLUDE: • DEMOLITION OF CASEWORK • CONSTRUCTION OF PARTITIONS AND DOORS • NEW PAINT AND FLOORING THROUGHOUT SUITE • RELOCATION OF LIGHT FIXTURES • NO STRUCTURAL WORK • NO ALTERATIONS OF CORE AREA OF WORK: SUITE 100: 334 SQ. FT. SUITE 111: 3,232 SQ. FT. TOTAL AREA OF WORK: 3,566 SQ. FT. AREA OF FLOOR: 9,632 SQ. FT. OCCUPANCY TYPE: B -OFFICE CONSTRUCTION TYPE: V-A APPLICABLE CODES: 2012 INTERNATIONAL BUILDING CODE 2009 INTERNATIONAL FIRE CODE 2009 INTERNATIONAL PLUMBING CODE 2009 INTERNATIONAL MECHANICAL CODE 2009 NATIONAL ELECTRICAL CODE ICC/ANSI 117.1- ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES WASHINGTON STATE ENERGY CODE (WSEC), WAC 51-11 WASHINGTON INDOOR AIR QUALITY CODE ASSESSOR'S PARCEL#: 262304-9143 LEGAL DESCRIPTION LOT 3 OF CITY OF TUKWILA SHORT PLAT NO L97-0049 RECORDING NO 9711069009 SAID SHORT PLAT DEFINED - PORTION OF E 1/2 OF NW 1/4 OF SE 1/4, BEGIN NE CORNER OF SAID E 1/2 BEING N 88-05-42 W 1339.34 FT FROM NE CORNER OF SE 1/4 TH'S 01-47-29 W 1322.34 FT TO SOUTHEAST CORNER TH N 87-55-02 W 659.35 FT TO W LINE OF E 659.34 FT OF SAID E 1/2 TH N 01-47-29 E 1320.30 FT TO N LINE OF SAID E 1/2 TH S 88-05-42 E 659.34 FT TO POB LESS PORTION FOR 59TH AVE,;3OUTH LESS PORTIONS FOR STREETS AS CONVEYED BY DEED, RECORDING NO 7907120770 LESS PORTION CONVEYED TO CITY OF TUKWILA FOR ROAD BY DEED, RECORDING NO 9408290327 PROJECT DIRECTORY TENANT WASHINGTON AUDIOLOGY SERVICES INC. 6987 PERIMETER ROAD S, SUITE 100 SEATTLE, WASHINGTON 98108 TELEPHONE: (206) 764-3330 FAX: (206) 764-4760 DESIGNER MARVIN STEIN AND ASSOCIATES, LLC 1500 WESTLAKE AVENUE N., SUITE ONE SEATTLE, WASHINGTON 98109 CONTACT: ERIN GOODELL TELEPHONE: (206)441-1449 FAX: (206) 441-4361 EMAIL: e.goodell@marvinsfein.com GENERAL NOTES 1. COMPLY WITH ALL APPLICABLE CODES. BUILDING REPRESENTATIVE PINNACLE COMMERCIAL 635 ANDOVER PARK WEST, SUITE 107 TUKWILA, WASHINGTON 98188 CONTACT: SHANNON MILLER TELEPHONE: (206) 903-0662 FAX: (206) 575-1198 EMAIL: smiller@pinnaclefamily.com CONTRACTOR TBD REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2013 City of T Ida BUILDING I ISION 2. THE GENERAL CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY THE FIELD CONDITIONS PRIOR TO PURCHASING MATERIALS OR COMMENCING THE WORK. 3. REPORT ANY DISCREPANCIES BETWEEN ACTUAL FIELD CONDITIONS AND DRAWINGS TO ARCHITECT BEFORE PROCEEDING WITH THE WORK. 4. VERIFY THE BUILDING STANDARDS (BIS) BEFORE PROCEEDING WITH THE WORK. 5. OBTAIN ALL REQUIRED PERMITS AND APPROVALS BEFORE PROCEEDING WITH THE WORK. 6. WALLS, PARTITIONS AND CEILINGS SHALL BE INDEPENDENTLY BRACED TO RESIST SEISMIC FORCES. 7. PROVIDE BLOCKING AT ALL WALL MOUNTED ITEMS. 8. ALIGN AND SHIM TRANSITIONS BETWEEN OLD AND NEW CONDITIONS. 9. LEVEL THE FLOOR. DEVIATIONS OF ± 1/2" WITHIN 10'-0" IS THE ACCEPTABLE LIMIT. 10. GENERAL CONTRACTOR REVIEW AND STAMP OR MARK REQUIRED SUBMITTALS AND SHOP DRAWINGS PRIOR TO SENDING COPIES TO MSA FOR REVIEW AND COMMENT. 11. THE BUILDING OWNER OR THE OWNER'S AUTHORIZED REPRESENTATIVE SHALL ESTABLISH WORKING TIME AND STANDARDS OF CONDUCT. 12. DO NOT SCALE DRAWINGS. 13. THE GENERAL CONTRACTOR SHALL COORDINATE THE ACTIVITIES OF ALL SUBCONTRACTORS, DELIVERY, AND THE STAGING OF MATERIALS. 14. GENERAL CONTRACTOR SHALL NOT START CASEWORK UNTIL CONFERENCE / COPY / BREAK / WORK ROOM CASEWORK SHOP DRAWINGS HAVE BEEN REVIEWED BY MSA. MECHANICAL, PLUMBING, FIRE PROTECTION AND LIFE SAFETY NOTES 1. MECHANICAL, FIRE PROTECTION AND LIFE SAFETY ALTERATIONS AND CONSTRUCTION ARE BY OTHERS, UNDER SEPARATE PERMITS BY DESIGN BUILD CONTRACTORS - DEFERRED SUBMITTALS. 2. REBALANCE THE HVAC SYSTEM AND PROVIDE WRITTEN REPORT TO OWNER AND/OR ARCHITECT. 3. CLEAN ALL DIFFUSERS & GRILLS. 4. VERIFY LOCATION OF THERMOSTATS WITH OWNER OR ARCHITECT PRIOR TO FINAL INSTALLATION. 5. ALL CONSTRUCTION WORK IS CONFINED TO THE BUILDING INTERIOR. CONTRACTOR SHALL PROVIDE BARRIERS OR SYSTEMS TO CONTAIN DUST, DIRT OR DEBRIS TO MINIMIZE INCONVENIENCE TO OTHER TENANTS WITHIN THE BUILDING. 6. CONSTRUCTION OPERATIONS SHALL NOT OBSTRUCT HALLWAYS, CORRIDORS, STAIRWAYS OR MEANS OF EGRESS FOR THE TENANTS OF THE BUILDING. 7. DO NOT DISRUPT HVAC, PLUMBING, ELECTRICAL OR FIRE PROTECTION SYSTEMS WITHOUT PRIOR AUTHORIZATION FROM OWNER. 8. THE CONSTRUCTION SITE SHALL BE LEFT CLEAN & ORDERLY AT THE END OF EACH WORK DAY. 9. NO ONE WILL OCCUPY THE AREA OF WORK OTHER THAN AUTHORIZED CONSTRUCTION PERSONNEL. 10. THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY CONSTRUCTION BARRIERS TO INHIBIT ACCESS BY NON -AUTHORIZED PERSONNEL & AS REQUIRED BY O.S.H.A. STANDARDS TO PREVENT INJURIES OR ACCIDENTS. 11. N.F.P.A. / I.F.C. APPROVED FIRE EXTINGUISHERS SHALL BE LOCATED WITHIN 75 FEET FROM ANY POINT ALONG THE PATH OF TENANT EGRESS OR AS REQUIRED BY THE LOCAL FIRE MARSHAL. 12. THE SPACE AROUND PIPES DUCTS ETC. PENETRATING FIRE RESISTANT CONSTRUCTION SHALL NOT EXCEED 1/2" & SHALL BE PACKED SOLID WITH APPROVED FIRE SAFING MATERIAL & SEALED WITH METAL ESCUTCHEONS EACH SIDE AS REQUIRED BY CODE. 13. MAINTAIN INTEGRITY OF RATED ASSEMBLIES AND REPAIR ANY DAMAGE TO SPRAY APPLIED FIRE PROOFING. RECEIVED CITY OF TUKWILA SEP 2 7 2013 PERMIT CENTER 11 I PROJECT INFORMATION NA SOUTHCENTER CORPORATE SQUARE - BLDG. 8 635 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 FILE COPY ft No. pv27-47Ds Flan resew wont is - • a, ;,l to ems all Ixtbzims, Approval of constraon documents does not a f l'c °':'..3 the violation of any code or ordinance. iter ;.,t �( r t is } ./FJV.y ota'p approved Fieki \'_p *# 1t'•iI •' !• q7 11 dgii:S. �t B o V Pc101 City Of Tukwila BUILDING DIVISION 1500 WESTLAKE AVE N, SUITE ONE, SEATTLE WA, 98109 (206) 441-1449 DRAWN BY: DA CHECKED BY: EG JOB NO.: 99135.091 N0. REVISIONS INDICATED THUS n DATE BY ISSUED FOR REVIEW TENANT REVISIONS 9/13/13 EG 9/25/13 EG TENANT: WASHINGTON AUDIOLOGY SHEET TITLE: FIRST FLOOR COVER SHEET REPRODUCTION, ALTERATION OR PUBUCA11ON OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2013. TI -1 OF 3 TI-2—SCCS8—WA—DEPL.dwg CP 0 0 a 0 0 0 0) oo CP O iC° 0� 0 625 Qoo 0 .) COI N o NN N � I o M CO CO N ��Q N U n°II-cn c ai ai �•,i DEga2 or-cnox 8 19 DEMOLITION PLAN 1/8" =1'-0" • 8 • 9 PTN./ MUL. PTN./ MUL. 19 0 C D� CONFERENCE OPEN WORK AREA OFFICE EQ. OFFICE OFFICE OFFICE WORK AREA V-0" MIN. WORK AREA RECEPTION OPEN WORK AREA OFFICE COPY/ WORK OFFICE CONFERENCE CONSTRUCTION PLAN 1/8" =1'-0" DEMOLITION LEGEND EXISTING BUILDING CORE TO REMAIN. EXISTING CONSTRUCTION TO REMAIN. EXISTING CORRIDOR PARTITION. EXISTING DEMISING PARTITION. EXISTING CONSTRUCTION TO BE DEMOLISHED. DEMOLITION KEYNOTES • EXISTING UPPER CASEWORK TO BE REMOVED. PATCH AND PREP WALLS AS REQUIRED TO RECEIVE NEW FINISHES AS SCHEDULED. OZ EXISTING UPPER CASEWORK TO BE REMOVED. PATCH AND PREP WALLS AS REQUIRED TO RECEIVE NEW FINISHES AS SCHEDULED. EXISTING LOWER CASEWORK TO REMAIN. O3 EXISTING FURNITURE WHIPS TO BE REMOVED. O4 EXISTING CASEWORK TO REMAIN. OEXISTING DOOR ASSEMBLY TO REMAIN. O EXISTING RELITE ASSEMBLY TO REMAIN. • REMOVE PORTION OF EXISTING PARTITION TO ACCOMMODATE NEW RELITE ASSEMBLY. REFER TO THE CONSTRUCTION PLAN. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2013 City of Tukwila BUILDING DIVISION CONSTRUCTION LEGEND EXISTING BUILDING CORE. EXISTING CORRIDOR PARTITION. EXISTING BIS DEMISING PARTITION. NEW B/S TENANT INTERIOR PARTITION. SEE DETAIL 7/TI-1. 2H3—= NEW B/S 3'-0" DOOR AND 2'-0" RELITE ASSEMBLY. ALIGN. CONSTRUCTION NOTES 1. MAINTAIN A CLEAR PATH OF TRAVEL AT ALL TIMES DURING CONSTRUCTION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES & THE BUILDING OWNER / MANAGEMENT AND TENANT. 3. INSTALL DOUBLE STUDS AT DOOR JAMBS AND HEADERS. 4. PROVIDE FIBER GLASS REINFORCED WATER RESISTANT GYPSUM BOARD IN AREAS SUSCEPTIBLE TO MOISTURE. 5. DIMENSIONS ARE FINISH SURFACE TO FINISH SURFACE, U.N.O. 6. REPORT ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL FIELD CONDITIONS TO THE ARCHITECT. 7. NEW FLOOR AND WALL FINISHES THROUGHOUT AREA OF WORK, TBD. CONSTRUCTION KEYNOTES 0 NEW BIS RELITE ASSEMBLY TO MATCH EXISTING ADJACENT IN SIZE, STYLE, AND DETAIL. DEMOLITION NOTES 1. A CLEAR PATH OF EGRESS TRAVEL SHALL REMAIN OPEN AT ALL TIMES DURING DEMOLITION. 2. DISRUPTION OF THE BUILDING FIRE ALARM, ELECTRICAL POWER, WATER, OR LIFE SAFETY SYSTEMS MUST BE COORDINATED WITH ALL GOVERNING AGENCIES AND THE BUILDING MANAGEMENT. 3. ALL DEBRIS SHALL BE REMOVED FROM THE CONSTRUCTION SITE DAILY. 4. ALL DEMOLITION SHALL BE PERFORMED IN ACCORDANCE WITH THE BUILDING MANAGEMENTS RULES AND REGULATIONS WITH MINIMAL DISTURBANCE TO OTHER TENANTS. 5. THE CONTRACTOR SHALL PROVIDE DUST BARRIERS FOR PROTECTION OF EXISTING ADJACENT AREAS. ALL HVAC SYSTEMS ARE TO BE PROTECTED DURING DEMOLITION. 6. THE CONTRACTOR SHALL NOTIFY THE OWNER AND MSA OF ANY DEMOLITION WORK THAT IMPACTS THE STRUCTURAL INTEGRITY OF THE BUILDING. 7. THE GENERAL CONTRACTOR SHALL IMMEDIATELY REPORT ALL ACCIDENTS, ERRORS OR DEFECTS TO THE BUILDING MANAGEMENT. 0 DOOR SCHEDULE 6", UNLESS OTHERWISE NOTED a. B/S LATCHSET. b. EXISTING HARDWARE TO REMAIN. DOOR NUMBER TYPE OF DOOR A. NEW B/S 3'-0" WIDE X BIS 8'-0" X 1-3/4" THICK PAINTED HC WOOD DOOR IN B/S PAINTED WOOD FRAME. B. EXISTING DOOR TO REMAIN. HARDWARE NOTES: 1. PROVIDE CODE COMPLIANT HARDWARE. ALL HARDWARE TO BE LEVER -TYPE. HANDLES, PULLS, LATCHES, LOCKS, AND OTHER OPERABLE PARTS ON ACCESSIBLE DOORS SHALL HAVE A SHAPE THAT IS EASY TO GRASP WITH ONE HAND AND DOES NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST TO OPERATE. OPERABLE PARTS OF SUCH HARDWARE SHALL BE 34" MIN. AND 48" MAX. ABOVE THE FLOOR. 2. THE MAXIMUM FORCE FOR PUSHING OR PULLING OPEN DOORS OTHER THAN FIRE DOORS SHALL BE AS FOLLOWS: INTERIOR HINGED DOOR = 5.0 POUNDS (22.2 N), SLIDING OR FOLDING DOOR = 15.0 POUNDS (67 N). THESE FORCES DO NOT APPLY TO THE FORCE REQUIRED TO RETRACT LATCH BOLTS OR DISENGAGE OTHER DEVICES THAT HOLD THE DOOR IN A CLOSED POSITION. FIRE DOORS SHALL HAVE A MINIMUM OPENING FORCE ALLOWABLE BY THE APPROPRIATE ADMINISTRATIVE AUTHORITY. 3. THRESHOLDS AT DOORWAYS SHALL NOT EXCEED 0.5 INCH (12.7 MM) IN HEIGHT. RAISED THRESHOLDS AND FLOOR LEVEL CHANGES GREATER THAN 0.25 INCH (6.4 MM) AT DOORWAYS SHALL BE BEVELED WITH A SLOPE NOT GREATER THAN ONE UNIT VERTICAL IN TWO UNITS HORIZONTAL (50 -PERCENT SLOPE). 4. EXIT DOORS MUST REMAIN UNLOCKED AT ALL TIMES IN THE DIRECTION OF EGRESS. PASSAGE EXIT HARDWARE SHALL REQUIRE NO SPECIAL KNOWLEDGE OR ASSISTANCE TO OPEN OR TO ACCESS. 5' 10' p �3� 3a3 20' 30' RECEIVED CITY OF TUKWILA SEP 2 7 2013 PERMIT CENTER SOUTHCENTER CORPORATE SQUARE - BLDG. 8 635 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 1500 WESTLAKE AVE NSUITE ONE, SEATTLE WA, 98109 (206) 441-1449 DRAWN BY: DA CHECKED BY: EG JOB NO.: 99135.091 NO. REVISIONS INDICATED THUS n DATE BY ISSUED FOR REVIEW 9/13/13 EG TENANT REVISIONS 9/25/13 EG TENANT: WASHINGTON AUDIOLOGY SHEET TITLE: FIRST FLOOR DEMOLITION AND CONSTRUCTION PLANS REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2013. TI -2 OF 3 TI-3—SCCS8—WA—CLPO.dwg 0 D 0 O T 0) 0 0 c 0 0) 00 0-N -0 p N ~ L 2,23 ac0 U c I I :3 ov N N N _ I c.f)cnI mm N tea -.-U 049-3 II uN cn c.1 rn c ai ai 0E8E2 ORMOX 8 9 4r REFLECTED CEILING PLAN 1/8" = (D) ELEC./COMM. FLOOR PLAN 1/8" =1'-0" CEILING LEGEND I_I L____J REMOVED/RELOCATED. EXISTING CEILING GRID AND TILES TO REMAIN. EXISTING 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO REMAIN. EXISTING 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE UPGRADED FOR EMERGENCY LIGHTING. LAYOUT SHOWN IS CONCEPTUAL ONLY. EXISTING 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES TO BE NEW OR RELOCATED BIS 2'X2' AND 2'X4' RECESSED FLUORESCENT LIGHT FIXTURES. EXISTING HVAC LOCATIONS (SHOWN FOR REFERENCE ONLY). Q EXISTING B/S RECESSED FLUORESCENT DOWNLIGHT. • SPRINKLER (SHOWN FOR REFERENCE ONLY, SPRINKLER SUBMITTAL BY OTHERS) 'N' ILLUMINATED EXIT SIGN (DIRECTIONAL WHERE SHOWN). B/S LIGHT SWITCH. NEW OR RELOCATED. LIGHTING CALCULATION (SUITE 100) GRID CEILING @ 8'-8" A.F.F. 0 WATTS/FIXTURE # OF FIXTURES TOTAL WATTS 32 2 64 62 3 186 48 1 48 TOTAL: 298 WATTS PROPOSED 334 TOTAL SF x .9 WATTS PER SF = 300.6 ALLOWABLE WATTS. TOTAL PROPOSED WATTAGE IS 298 - WHICH IS LESS THAN THE ALLOWABLE WATTAGE PER 2012 WSEC INTERIOR LIGHTING POWER ALLOWANCE - BUILDING AREA METHOD, CHAPTER 4, C405.5.2 (TABLE C405.5.2(1)). REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 9 2013 City of Tukwila BUILDING DIVISION ELEC / COMMUNICATIONS LEGEND B/S WALL MOUNTED DUPLEX ELECTRICAL OUTLET. BIS WALL MOUNTED DEDICATED 120V 20A DUPLEX ELECTRICAL OUTLET. BIS WALL MOUNTED FOURPLEX ELECTRICAL OUTLET. B/S WALL MOUNTED DEDICATED 120 V 20A FOURPLEX ELECTRICAL OUTLET. BIS WALL MOUNTED COMBINATION VOICE/DATA OUTLET. CORE DRILL. (POWER, VOICE & DATA REQUIREMENTS PER PLAN) JUNCTION BOX. EXISTING BLANK COVERPLATE. FURNITURE WHIP. 'N' NEW. 'U' UPGRADE EXISTING. CEILING NOTES 1. CHECK FOR CONFLICTS BEFORE INSTALLING OR RELOCATING LIGHT FIXTURES. NOTIFY MSA OF ANY CONFLICT(S). 2. REPLACE DAMAGED CEILING TILES AND GRID AS NECESSARY TO BRING CEILING TO "LIKE NEW" CONDITION. 3. MAINTAIN EXISTING ONE FOOTCANDLE PER SQUARE FOOT AT EGRESS PATHWAY LIGHTING. 4. MAINTAIN 42" CLEAR SPACE IN FRONT OF THE PANEL SIDE OF ANY V.A.V. BOXES. 5. DAYLIGHT ZONE CONTROL: DAY LIGHTING AS DEFINED BY CODE SHALL BE PROVIDED WITH INDIVIDUAL CONTROLS, OR DAYLIGHT OR OCCUPANT SENSING AUTOMATIC CONTROLS PER SECTION C405.2.2.3 OF THE 2012 WASHINGTON STATE ENERGY CODE. 6. FIRE SPRINKLERS BY OTHERS UNDER DEFERRED SUBMITTALS. 7. COMMISSIONING REQUIREMENTS: TEST LIGHTING CONTROLS TO ENSURE THAT THE SYSTEMS COMPLY WITH CODES. PROVIDE A WRITTEN REPORT OF TEST PROCEDURES AND RESULTS TO THE OWNER. SWEEP CONTROLLERS ARE NOT BUILDING STANDARD, USE OCCUPANCY SENSORS AS REQUIRED. 8. EXIT SIGNS ARE INDICATED ON THE REFLECTED CEILING PLAN. THEIR PLACEMENT IS BASED UPON EXISTING CONDITION SURVEY. FINAL NUMBER OF SIGNS, THEIR PLACEMENT AND ARROW DIRECTIONS SHALL BE FIELD VERIFIED WITH THE BUILDING OFFICIAL, CONTRACTOR AND ARCHITECT. REFLECTED CEILING KEYNOTES O1 NO CEILING WORK IN THIS AREA. LIGHTING CALCULATION (SUITE 111) GRID CEILING @ 8'-8" A.F.F. 0 L WATTS/FIXTURE # OF FIXTURES TOTAL WATTS 32 6 192 62 33 2,046 48 1 48 TOTAL: 2,286 WATTS PROPOSED 3,232 TOTAL SF x .9 WATTS PER SF = 2,908.8 ALLOWABLE WATTS. TOTAL PROPOSED WATTAGE IS 2,286 - WHICH IS LESS THAN THE ALLOWABLE WATTAGE PER 2012 WSEC INTERIOR LIGHTING POWER ALLOWANCE - BUILDING AREA METHOD, CHAPTER 4, C405.5.2 (TABLE C405.5.2(1)). ELEC. / COMMUNICATION NOTES 1. ALL ELECTRICAL OUTLETS TO BE MOUNTED AT 15" A.F.F. (AT BASE OF OUTLET) PER W.S.B.C. REQUIREMENTS U.N.O. 2. ROUGH IN ALL DATA AND COMMUNICATION LINES - MUD RING WITH PULL STRING, U.N.O. 3. PROVIDE NEW COVER PLATES AND RECEPTACLES AS NEEDED TO MATCH BUILDING STANDARD. 4. MAINTAIN EXISTING ELECTRICAL OUTLETS UNLESS LOCATION CONFLICTS WITH NEW CONSTRUCTION. 5. THE CONTRACTOR SHALL COORDINATE ELECTRICAL, LIGHTING, CASEWORK AND FURNITURE. ELEC / COMMUNICATIONS KEYNOTES 0 EXISTING 6 -PLUG ELECTRICAL OUTLET. VERIFY WORKING CONDITION AND COORDINATE WITH TENANTS FURNITURE VENDOR. 0 5' 10' 20' k°5. 30' 3 RECEIVED CITY OF TUKWILA SEP 2 7 2013 PERMIT CENTER SOUTHCENTER CORPORATE SQUARE - BLDG. 8 635 ANDOVER PARK WEST TUKWILA, WASHINGTON 98188 1500 WESTLAKE AVE N. SUITE ONE, SEATTLE WA, 98109 (206) 441-1449 DRAWN BY: DA CHECKED BY: EG JOB NO.: 99135.091 NO. REVISIONS INDICATED THUS n DATE BY ISSUED FOR REVIEW 9/13/13 EG TENANT REVISIONS 9/25/13 EG TENANT: WASHINGTON AUDIOLOGY SHEET TITLE: FIRST FLOOR REFLECTED CEILING AND ELECTRICAL/ COMMUNICATION PLANS REPRODUCTION, ALTERATION OR PUBLICATION OF THIS DRAWING, WITHOUT EXPRESSED PERMISSION BY MSA, IS A VIOLATION OF FEDERAL COPYRIGHT LAW. COPYRIGHT BY MSA 2013. TI -3 OF 3