Loading...
HomeMy WebLinkAboutPermit D13-306 - 571 STRANDER - BUILDING A REROOFBUILDING A 571 STRANDER BL D13-306 wq City oolukwila Department of CommunityDevelopment 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 0223300010 Address: 571 STRANDER BL TUKW Suite No: Project Name: BUILDING A DEVELOPMENT PERMIT Permit Number: D13-306 Issue Date: 10/08/2013 Permit Expires On: 04/06/2014 Owner: Name: IIT ANDOVER DC LLC C/O INDU Address: 518 17TH ST 17TH FL , DENVER CO 80202 Contact Person: Name: JOE DICARLO Address: 13105 HOUSTON RD , SUMNER WA 98390 Contractor: Name: WAYNE'S ROOFING INC Address: 13105 HOUSTON RD , SUMNER, WA 98390 Contractor License No: WAYNESR205Q5 Lender: Name: SELF FUNDED - IIT ANDOVER INVESTMENT LLC Address: 249 SW 41 ST , RENTON WA 98057 Phone: 253-863-4455 Phone: 253-863-4455 Expiration Date: 05/02/2015 DESCRIPTION OF WORK: ROOFING RECOVER - PREPARE EXISTING ROOFING FOR RECOVER, MECHANICALLY ATTACH 1/2" RECOVER BOARD, NEW SINGLE PLY HOT AIR WELD ROOFING MEMBRANE, REPLACE EXISTING METAL & GUTTERS, REPLACE EXISTING SKYLIGHTS WITH NEW SKYLIGHTS Value of Construction: $215,875.00 Fees Collected: $4,125.54 Type of Fire Protection: International Building Code Edition: 2012 Type of Construction: Occupancy per IBC: 0025 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-306 Printed: 10-08-2013 Public Works Activities: :.hannelization / Striping: N :3urb Cut / Access / Sidewalk / CSS: N 'ire Loop Hydrant: :food Control Zone: Iauling: :,and Altering: :,andscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Nater Main Extension: Nater Meter: ?ermit Center Authorized Signature: hereby certify that I have read and joverning this work will be complie ['he granting of this permi :onstruc ' or the rformance of wor o this N N N Number: 0 Start Time: Volumes: Cut 0 c.y. Size (Inches): 0 End Time: Fill 0 c.y. Start Time: End Time: Private: Profit: N Private: Date: Public: Non -Profit: N Public: [0 I ned this permit and know the same to be true and correct. All provisions of law and ordinances , whether specified herein or not. e to • aut ve authority to violate or cancel the provisions of any other state or local laws regulating orized to sign and obtain this development permit and agree to the conditions attached Signature: ?Tint Name: c� l TD C4, \.9 ['his permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended )r abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: l: ***BUILDING DEPARTMENT CONDITIONS*** 3: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the 3uilding Official. 3: All permits, inspection records, and approved plans shall be at the job site and 'available to the inspectors prior to ;tart of any construction. These documents shall be maintained and made available until final inspection approval is granted. All construction shall be done in conformance with the approved plans and the requirements of the International 3uilding Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 3: Prior to final inspection for this building permit, a copy of the roof membrane manufacturer's warranty certificate ;hall be provided to the building inspector. 3: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, my violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits ?resuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila ioc: IBC -7/10 D13-306 Printed: 10-08-2013 shall not be valid. The issuance of a permit d on construction documents and other dat l not prevent the Building Official from requiring the corrects f errors in the construction documents and data. doc: IBC -7/10 D13-306 Printed: 10-08-2013 CITY OF TUESLA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. p 13._ s6p Project No. Date Application Accepted: 9-30-13 Date Application Expires: . 3O 1 9 (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 571 5 SI STrC LQ>` - \V 0 Tenant Name: 12)1t.A.10\1.3 (0 APS King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes -®". No $.Es - k tver\aejr, 3 Aa le -ore ' w.Ne. - p c c Z in el- Lea." L. ut a o '{ vk z E ctc-e_ PROPERTY OWNER Name: 1 iT A rv:1w e.c- 11.1k1 QST 1' il'T t -L b'T LAX., Address: Z�4 W 74 t..% -t- S-rree_�p�� City: "Ncn i..•.§ak 9 f3 ig ra"'1 CONTACT PERSON - person receiving all project communication **‘,\ Name: - t -� i(4 \c ` n47 flAaQi Addres : t \c 7LaS`QR�u. City: Y1�� to 9 Ap3ci. 0 Ph S3 863-1qs lx: a- C , —311 Email: o Q (I t.,30 -y RES c' O o ►'S 6, OD GENERAL CONTRACTOR INFORMATION Company Name: ` Address: L3 (-��a.J.c� �+-�S City: �+.Yh ss l�H-te: ,c)C .S3 73 Phone.Far bto —4 455". 7..-536; h 53(1 Contr Reg No.: Exn Date: \..04,4-rvNE5R7_OS S Tukwila Business License No.: H:\Applicatlons\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 ARCHITECT OF RECORD ame: Companyg \ s7ceiCcT cfsn5 t.L�� vw.b Architect Name: �A a...V.4-st` Li Address:_ 3303--cr3.VOP *le_: --i l City: ttimi4 tat ' 9tiopZlo Phone: F '1i 4. 54.5 ZLoiQ Email: Mc 1krc---y(0 t.x;es ccL r c .oe, ENGINEER OF RECORD Company Name. C AS ['s cr °� S T c ci sl)...4 ("xi trq. art Enginee Name: � tt4 V .Iv a thin c. s. Address: 101 0 Z. gip A Je. tS— g: Cit no AI. 1.5 t l�tt? ci gito (o Phone:,q c q flFax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Num: ''etav_ l iii 14.11Is•STr''t LLC Address: Z� L. ct9 t :r 1 ST City: _ .vort.iJ te: q „7 Page 1 of 4 BUILDING PERMIT INFORMATI— 206-431-3670 Valuation of Project (contractor's bid price): $ 2_ (� ��l S Existing Building Valuation: $ Describe the scope of work (please provide detailed information): V,0 . r..:. :>*.v ' a'9 - R °�� 5 \e ''\ M \ - \ aAtk V`Op N Vv -NQ r1 41e_ ^ F Lrr Mcg \ v.\ s --s is $kAiltetl.-4,-N Will there be new rack storage? ❑ ....Yes o If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No If `yes', attach list of materials and storagelocations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Lme2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1" Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport • Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers 0 Automatic Fire Alarm ❑ None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No If `yes', attach list of materials and storagelocations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplications\Forms-Applications On Lme2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES -, • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILD IDIG.OWN AUT D AGENT: Signat Print Name: Mailing Address:13\O 5 x► -t Mt Date: —1 -3o- \ 3 253 Day Telephone:GDS '44-S3 H:\Applications\Forms-Applications On Line \2012 Applications\Fermit Application Revised - 2-7-12.docx Revised: February 2012 bh City State Zip Page 4 of 4 oar PUBLIC WORKS PERMIT INIMATION — 206-433-0179 • Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila ❑ ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑... Highline ❑ ...Valley View 0...Renton ❑ ...Sewer Availability Provided 0... Renton 0... Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0...Insurance ❑... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 ❑ .. Total Cut ❑ .. Total Fill cubic yards cubic yards 0... Geotechnical Report 0... Maintenance Agreement(s) ❑ .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0...Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance ❑... Work in Flood Zone 0... Storm Drainage ❑ .. Sanitary Side Sewer El...Abandon Septic Tank ❑... Grease Interceptor ❑ .. Cap or Remove Utilities 0... Curb Cut ❑... Channelization ❑ .. Frontage Improvements 0...Pavement Cut 0...Trench Excavation ❑ .. Traffic Control 0...Looped Fire Line ❑... Utility Undergrounding ❑ .. Backflow Prevention Fire Protection " Irrigation Domestic Water ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size ❑ .. Sewer Main Extension Public ❑ .. Water Main Extension Public 57 WO # (2) " WO # (3) " WO # WO # (2) " WO # (3) " WO # WO # 0 .. Deduct Water Meter Size ,, Private 0 Private 0 FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) ❑ .. Water ❑ .. Sewer ❑ .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Mailing Address: Day Telephone: City State Zip H:\Applications\Forms-Applications On Line\20I2 Applications\Permit Application Revised - 2-7-I2.docx Revised: February 2012 Page 3 of 4 • • City of Tukwila nl �Z Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 0223300010 Address: 571 STRANDER BL TUKW Suite No: Applicant: BUILDING A RECEIPT Permit Number: D13-306 Status: PENDING Applied Date: 09/30/2013 Issue Date: Receipt No.: R13-02769 Initials: WER User ID: 1655 Payment Amount: $4,125.54 Payment Date: 09/30/2013 03:18 PM Balance: $0.00 Payee: WAYNE'S ROOFING INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8379 4,125.54 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $4,125.54 2,497.60 1,623.44 4.50 rinr Rorcin+-r1R Printed: 09-30-2013 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3 Permit Inspection Request Line (206) 431-2451 pip -30C ProjeetjZ ./ i✓G ,4Type of Inspection: Address: C 7/ S,—R/tAJL Z -- Date Called: Special Special Instructions: o v Date Wanted:iP" /� aim. L "-: Requester:Cic–' ,1 PhoneNo: .2o6, - 293 —6356 Approved per applicable codes. EJ Corrections required prior to approval. COMMENTS: 5 rA/A i1/6>1l e^hjz. (jos-rector Date: e--14 nREI REISPE"TION FEE REQUIRPrior to next inspection, fee must be pai at' 00 Southcenter Blvd., uite 100. Call to schedule reinspection. INSPECTION RECORD - Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 •- (206) 431-3670 Permit Inspection Request Line (206) 431-2451 I 3-30 Pro'ect:. (3z.I % IC\;k� A Type of Inspection: ?Ds- 2F RCO+' Address: 571 S —$ANDe2 Date Called: Special Instructions: Date Wanted: I2 -Z- )-3p.m. 6a D' Requester: Phone No: c5 3-CooG- 7781 V.Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: REINSPECTION FEREQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date/ e' 2,2 / r 0ilia-3o,65 Roofing Guarantee ,.> ; Whereas, WAYNE'S ROOFING, INCORPORATED, of Sumner, Washington, herein called "the Contractor," has completed application of the following roof Owner: IIT Andover DC, LLC C/O: KG Investment Management, LLC Address of owner: 249 S. W. 41st Street, Renton, WA 98057 Type and Name of Building: Andover Distribution Center— Bldg. A Location 551— 581 Strander Blvd, Tukwila, WA 98188 Area of Roof 80,100 Square Feet Date of Completion: December 16, 2013 Date Guarantee Expires: December 15, 2018 Whereas, at the inception of such work the Contractor agreed to guarantee the aforesaid roof against faulty materials or workmanship for a limited period and subject to the conditions herein set forth: Now, Therefore, the Contractor hereby Guarantees, subject to the conditions herein set forth, that during a period of FIVE ( ) years from the date of completion of said roof it will, at its own cost and expense, make or cause to be made such repairs to said roof and composition flashing resulting solely from faults or defects in materials or workmanship applied by or through the Contractor as may be necessary to maintain said roof in watertight condition. This guarantee is made subject to the following conditions: 1. Specifically excluded from this guarantee is any and all damage to said roof, the building or contents caused by the acts or omissions of other trades or contractors; lightning, windstorm, hailstorm, or other unusual; phenomena of the elements; foundation settlement; failure or cracking of the roof deck; defects or failure of material used as a roof base over which the roof is applied, faulty construction of parapet wall, copings, chimneys, skylights, vents, supports, or other parts of the building; vapor condensation beneath the roof; penetrations for pitch boxes; or fire. If the roof is damaged by reason of any of the foregoing this guarantee shall thereupon become null and void for the balance of the guarantee period unless such damage is repaired by the Contractor at the expense of the party requesting such repairs. 2. The Contractor is not liable for consequential damages to the building or contents resulting from any defects in said roof or composition flashing. 3. No work shall be done on said roof, including, but without limitation, work in connection with flues, vents, drains, sign braces, railing, platforms or other equipment fastened to or set on the roof, and no repairs or alterations shall be made to said roof, unless the Contractor shall be first notified, shall be given the opportunity to make the necessary roofing application recommendations with respect thereto, and such recommendations are complied with. Failure to observe this condition shall render this guarantee null and void. The Contractor shall be paid for time and material expended in making recommendations or repairs occasioned by the work of others on said roof. 4. This guarantee shall become null and void if the roof is used as a promenade or work deck or is sprayed or flooded, unless such use was originally specified and the specification is noted in paragraph 8 below. Areas that pond water shall not be covered by this guarantee. 5. This guarantee shall not be or become effective unless and until the Contractor has been paid in full for said roof in accordance with the agreement pursuant to which such roof was applied. 6. This guarantee shall become null and void unless the Contractor is promptly notified of the alleged defect in materials or workmanship and provided an opportunity to inspect the roof. 7. This guarantee is in lieu of all other guarantees or warranties, express or implied 8. Additional conditions or exclusions: Includes new skylights/smoke vents, new sheet metal flashings, new gutters, and related work installed with new roof system as a portion of roofing contractor's work scope. In Witness Whereof, this instrument has been duly executed this 24th day of JanUarv, 2014 ROF TUKWILA CIT`( FEB 18 2011i PERMIT CENTER BY WAYNE'S ROOFING, INC. 13105 HOUSTON ROAD SUMNER,.W ASHINGTON. 98390 TAC. 5 863-4455 .SEA:(2O6)•575=0078 AUTI-10REED REPRESENTATIVE ■ Don Guthrie, President ■ Sika Sarnafil World Class Roofing and Waterproofing 10 Year System Warranty Warranty Serial No.: 0000013933-002314.1 SIKAPLAN ROOFING WARRANTY FOR COMMERCIAL BUILDING Building Owner: Building Name: Building Address: Applicator: IIT Andover DC, LLC Andover Distribution Center Building A 551-581 Strander Boulevard Tukwila, WA 98188-2920 Wayne's Roofing, Inc., 13105 Houston Road, Sumner, WA 98390 Date of Substantial Completion: 12/16/2013 Date of Inspection: 12/16/2013 By: Steven Shaver Building/Area Name: Andover Distribution Center Building A Used As: INDUSTRIAL BUILDINGS - WAREHOUSES Area Warranted: 83,070 sq. ft. Telephone: (253) 863-4455 Sika Sarnafil warrants to the owner of the building described above ("Owner"), that subject to the terms, conditions, and limitations stated herein, Sika Samafil will repair leaks originating from the Sikaplan Roofing Membrane, Sarnatherm Insulation or Sika Sarnafil Roofing Accessories installed according to Sika Sarnafil's Technical instructions by a Sika Samafil Authorized Roofing Applicator for a period of 10 (ten) years commencing with the date of substantial completion of the installation of the Roofing Membrane. TERMS, CONDITIONS, LIMITATIONS 1. Owner shall notify Sika Sarnafil on the first business day immediately following the discovery of each leak in the Roofing System and confirm in writing within one week. 2. If on Sika Samafil's inspection, Sika Samafil determines that the leak is caused by a defect in the Sikaplan Roofing Membrane, Samatherm Insulation or Accessory provided by Sika Sarnafil to the Applicator for this building or from a defect in the Sika Sarnafil Authorized Applicator's workmanship applied to that Sikaplan Membrane, except as provided in the following paragraph three (3) Owner's remedies and Sika Sarnafil's liability shall be limited to Sika Sarnafil's repair of the Roofing Membrane, Samatherm Insulation or Accessory. Sika Sarnafil's cumulative liability throughout the duration of this warranty shall not exceed the original installed cost of the Sikaplan Roofing System. 3. This warranty does not apply and may be null and void if any of the following occur: (a) The Roofing Membrane, Sarnatherm Insulation or Accessory is damaged by a natural disaster including, but not limited to, earthquake, lightning, hail, windstorm in excess of 60 mph (97 km/h), hurricane, or tornado, or: (b) The Roofing Membrane, Sarnatherm Insulation or Accessory is damaged by any act of negligence, accident, or misuse including, but not limited to, vandalism, falling objects, civil disobedience, or act of war, or: (c) A deficient pre-existing condition or equipment is causing water entry, or: (d) Metal work or other accessories or equipment is used in the Roofing and causes leaks, or: (e) There are any alterations or repairs made on or through the completed roof, or objects such as but not limited to fixtures, equipment, or structures are placed on or aftached to the completed roof without first obtaining written authorization from Sika Sarnafil, or: (f) Failure by the Owner or his lessee to use reasonable care in maintaining the roof as described in the Owner's Guide provided with this warranty, including that of sealants and caulking, or: (g) Loss of integrity of the building envelope and, or structure including, but not limited to partial or complete loss of roof decking, wall siding, windows, doors or other envelope components or from roof damage by wind blown objects, or: (h) Condensation accumulates in the roof assembly due to incorrect design or due to a reduction in the vapor barrier effectiveness, or: (i) A significant change in the use of the building by the Owner or his lessee expected by Sika Sarnafil to effect the Roofing Membrane as originally installed, or: (j) The Roofing Membrane is damaged by contaminates and/or spills, or: (k) Deficient design applied to the Roofing Membrane such as membrane contact with incompatible materials and/or substrates, or: (I) The Owner fails to comply with every term and condition stated herein. 4. During the period of this warranty, Sika Sarnafil, its agents and employees, shall have free access to the roof during regular business hours. 5. Should the Roofing Membrane be concealed, the cost of exposure of the Roofing Membrane for purposes of Sika Sarnafil's investigation and/or repair, such as removal and replacement of any paving or overburden, shall be the Owner's responsibility. 6. Sika Sarnafil shall have no obligation under this warranty until all invoices for materials, installation, and services have been paid for in full. 7. Sika Samafil's failure at any time to enforce any of the terms or conditions stated herein shall not be construed to be a waiver of such provision. 8. This warranty is extended solely and exclusively to the owner of the Building at the time the Sikaplan Roofing System is installed. It does not extend nor is it otherwise assignable or transferable to any other party unless approved in advance and in writing by Sika Sarnafil and the costs to process the transfer and to inspect and repair the Sikaplan Roofing System, if necessary, are paid for by the original owner. 9. The Owner and Sika Sarnafil hereby agree that any and all claims (contractual, statutory, common law or otherwise), disputes, or suits that in any way, directly or indirectly, arise out of or relate to this Warranty, or the alleged breach thereof, or to any contracts between the owner and Sika Sarnafil, or the alleged breach thereof, or to the design, manufacture, sale, distribution, installation, and/or inspection of the Sikaplan Roofing System, shall first be submitted to non-binding mediation before a neutral mediator jointly selected by the parties or, in the absence of agreement, as designated by the American Arbitration Association. In the absence of resolution by mediation, all such claims shall be settled by arbitration by the American Arbitration Association in accordance with the Construction Industry Arbitration Rules. Any such mediation and/or arbitration shall take place in Boston, Massachusetts. This Warranty, and any claims,- disputes or suits between the parties hereto shall be govemed by, and construed and enforced in accordance with, the laws of the Commonwealth of Massachusetts. 10. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. THE REMEDIES STATED HEREIN ARE EXCLUSIVE REMEDIES AND SIKA SARNAFIL SHALL NOT BE RESPONSIBLE OR LIABLE FOR ANY INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING THE PRESENCE OF MOLDS, FUNGI, BACTERIA, SPORES, MYCOTOXINS OR THE LIKE OR FURTHER LOSS OF ANY KIND WHATSOEVER, INCLUDING BUT NOT LIMITED TO, DAMAGE TO THE BUILDING ON WHICH THE COMPONENTS OF THE ROOF ARE SITUATED, DAMAGE TO THE CONTENTS THEREOF, LOSS OF USE OF THE BUILDING OR ANY COMPONENT PART THEREOF, OR DAMAGE TO ANY OTHER PROPERTY OR PERSONS. NO REPRESENTATIVE OF SIKA SARNAFIL HAS AUTHORITY TO MAKE ANY REPRESENTATIONS OR PROMISES EXCEPT AS STATED HEREIN. This Warranty Is Effective From: 12/16/2013 through: 12/16/2023 .L4( James Gildea _ ,/7/20,9_ b"44G. J, tat 1/7/2014 Date: Brian J. Whelan Date: Warranty Manager Senior Vice President ® Sika Sarnafll, A Division of Sika Corporation, 100 Dan Road, Canton, MA 02021 Sarnaf!® Tel.: 800-451-2502, Fax: 781-828-5365, www.sikacorp.com Page 1 of 1 FILE COP/ Permit No. ._4r2716. 25 Pi t 22'14'4515'eicr Oft CITY OF TUKWILA SEP 3 0 2013 :HERMIT CENTER FILE COP'Y f►.. ...raw• - . August 19, 2013 KG Investment Management 249 SW Forty -First Street Suite K Kent, WA 98055 Attention: Ron Montgomery RE: 581 Strander Boulevard Roofing Overlay Tukwila, Washington Dear Ron: CASCADE CREST CONSULTING ENGINEERS, INC. REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 2 2013 City of Tukwila BUILDING DIVISION Cascade Crest Consulting Engineers, Inc. performed a brief site visit to the building at 581 Strander Boulevard in Tukwila, Washington, on August 13, 2013, to gather information for a proposed roofing overlay to the building. Our site visit included observations and measurements of the existing roof structure. This letter summarizes our observations and findings. Existing Building Description The existing building is a one-story concrete tilt -up structure. Based upon our observations, the typical roof framing consists of 1-1/2" metal deck supported by 20" -deep open -web steel joists at 6'- 4" on -center, which are in turn supported by steel wide flange beams at 33'-6" on -center. Steel pipe columns and the perimeter concrete wall panels support the roof framing system. The ground floor consists of a concrete slab -on -grade. The foundation system likely consists of conventional concrete spread footings with continuous strip footings at the perimeter walls and square pad footings at the columns. The building was reportedly constructed in the 1960s. Observations and Findings The existing roofing system consists of a built-up roofing system which, according to Mr. Mark Curry of Westcoast Roof Consulting in Costa Mesa, California, weighs approximately 3.55 pounds per square foot (psf). According to Mr. Curry, the proposed roofing overlay system weighs approximately 1.6 psf. Utilizing the dead loads observed in the field, the above -noted roofing dead loads, and a code applied live load of 25 psf, the roof framing system appears to have adequate capacity to support the proposed roofing overlay system. Although the design Loads for the building are not known and details of the framing elements of the structure are not available, the calculated increase in dead plus live load on the roof structure is 5.3%. This increase is only slightly greater than the 5% increase permitted by Section 3403.3 of the 2012 Edition of the International Building Code. However, it is our opinion that no modifications to the existing structure are required to support the proposed roofing overlay. RECEIVED -NTV OF TUKWILA SEP 3 0 2013 ,JERIVIIT CENTER 21902 961h Ave. S.E. - Snohomish, WA 98296 - Phone: 206-909-7808 581 Strander Boulevard - Tukwila 2 August 19, 2013 We are pleased to assist you on this project. Should you have questions, please feel free to call me at (206) 909-7808 and discuss our findings. Sincerely, CASCADE CREST CONSULTING ENGINEERS INC. Keith Wm. Moore, S.E. Associate zls -1s Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www waynesroofing.com SUBMITTALS ROOFING REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. 6, 2013 PROJECT Andover Distribution. Center Bldg A FILE COPY s�o 1tNo. b - 581 Stander Blvd Pmt Pio miff/ approval Is oto errors and omissions. &p royal of construction dotards does not authorize Lt. V,3k ..t of an coda or ori Vt fit KG Investments Management 249 S.W. 41st Street Renton, WA 98057 Tukwila, WA PREPARED FOR REVIEWED FOR CODE COMPLIANCE APPROVED OCT 0 2 2013 City of Tukwila BUILDING DIVISION City Of 11Ukwfla BUILDING DIVISION Approved as submitted. Mark Curry Westcoast Roof Consulting 201 SEPARATE PERMIT REQUIRED FOR: 13140thanical Q'becctricai CIumbIng Otras Piping City of Tukwila ift_T_Qtryc DIVISION RECEIVED CITY OF TUKWILA SEP 3 02013 PERMIT CENTER WRI PROJECT 13-067 1)1,3 SUMNER (253) 863-4455 SEATTLE (206) 575-0078 FAX (253) 863-8311 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofna.com WAYNE'S ROOFING, INC. "1){511L111 Andover Distribution Ctr A ROOF DRAWINGS • Roof Plan/ System Descriptions 1 PRODUCT DATA • Roof System Product Data 2 CERTIFICATION • Approved Applicator Letter • UL Rating WARRANTIES • Manufacturer's Sample Warranty , • Contractor's Sample Warranty MSDS—Under Separate Cover RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER May 8, 2013 WRI PROJECT 13-067 r Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www wavnesroofina.com WAIN E'S HOOFING, IKC. itltlt//�l/1l DRAWINGS 1 RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER o - ,t-•'_, `.. ,,. 7°‘ ' -10 - 'j i'. ? [. •, -; 9 ) .., •:'.,''. `0,.> ' ee...7.1 ' ',•460,-_; -r I. "':.4 Ill , ,./1:Ze 11'' •' 4 _ , - z.., n v . , .. • . • ,,_' 0 • PIECEIVED CITY OF TUKWILA • SEP 31 2013 PERMIT CENTER b 0 B'- O' • Field Layout 6 FAST/BD 8'- O' Perimeter Layout 10 FAST/8D s'-0' • • • Corner Layout 16 FASTED INSULATION FASTENING PATTERN / u / 1 Insulation Data Bottom Middle Top MANUFACTURER WA N/A SARK APIL TYPE N/A N/A HD %Ms° THICKNESS WA WA W R - VALUE WA N/A 250 NO. OF LAYERS WA WA 1 ATTACHMENT WA WA Mecharicoly FASTENER TYPE L I N/A N/A XP FASTENER LENGTH N/A N/A 3• BOARD SIZE WA N/A gyrg• FELD FASrG N/A N/A 6 PERIMETER FASTG N/A WA 10 CORNER FASTG WA N/A 16 RI REQ. (Pattern Ory) WA WA WA e —Sarnafil XP Fastemer & Rhinobond Coated Plate (Sarnail 2x3 Pattern) /• New %° Sarntherm Roof Board H i Mechanically Attached Sarnfil SikaPlan 60 Mil PVC Membrane Induction Welded System Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 Existing 3 Ply Asphalt Applied BUR Assembly Over 15/16" Fiberglass insulation Over W Wood Fiber RECEIVED Over CITY OF TUKWILA Rosin Sheet — Slip Sheet Steel Deck (Existing) SEP 3 0 2013 PERMIT CENTER (253)&33-4485 Soo P06)575-0078 Fa( O53) sea,s3n Dare Drawn By 9.24,13 _ Joe D Andover Distribution Center- A l Job No System Description 13-067 Sr�re N.T.S. ISe`r'or, Sheer 1:131N33 11Wa3d r --r— 1 N 1 �I 1 NI 1 IV ___%-__ I I L _0 4 '< 33 On m 2' X 3' RHINOBOND FASTENING PATTERN cta CIE (CORNER) 16 PER BD. iD (PERIMETER) 10 PER BD. r --T 1 1 �I 1 1 (PERIMETER) 10 PER BD. r --T �I I (FIELD) 6 PER BD. PERIMETER & CORNER ATTACHMENT bTES: 1) PERIMETER AND CORNER AREAS ARE DETERMINED IN ACCORDANCE WITH ASCE-7: Yo LEAST PLAN WIDTH OR 440 ROOF HEIGHT BUT NOT LESS THAN 4 FT. 2) BOARDS CROSSING PERIMETER/CORNER AREA INTO FIELD AREA SHALL BE ATTCHED ACCORDING TO RESPECTIVE PERIMETER/CORNER RATES. 3) FOR HEIGHT > 60 FT, CORNER IS "L" SHAPED WITH DIMENSIONS (2 X "PERIMETER"). XP FASTENER h-3121 AND SARNADISC RHINOBOND Sarnafil let -B2 -540D socecom.CDm JOB NAME: RHINOBOND PERIMETER & CORNER ATTACHMENT scALEN.T.S. DATE 4/10 FILE NO.: RB -1 B DRW. NO. XXX AS A MFA®W WE IJANUFACTURER. $ICA SARNAFLL. A DIVISION OF MA CDFPORAT10N REVIEWS MAILS PREPARED NY THE CONSULTANT. AROKRECT ARDOR ENGINEER FOR A PROJECT SOLELY FOR THE PURPOSE OF DETERMINING IF A MU SARNAFIL WARRANTY MAY ISSUE FOR THE PROJECT. THIS REVIEW IS NOT TO BE CONSTRUED AS APPROVAL OF DETAILS BY &KA SARNKR ANC IS NOT BEING CONDUCTED N UEU OF SOUND ENON ERD0 ARD ARCHITECTURAL PRACTICER AND JUDGMENT AND SHOULD NOT BE RUED UPON FOR THAT PURPOSE MA CORPORATION ASSUMES N0 UAaL IY WITH RESPECT TO DIE DESIGN OF THE ROOFING OR WATERPROOFING SYSTEM THE ARCHITECT CONSI8TANT ANDER ENGINEER OR DESIGN PROFESSIONAL FORA PM4TTMAR PROTECT KARS THS SOLE RESPONSIBILITY FON THE OE90N OF THF ROOFING OR WATERPROOFING SYSTEM FOR THE PREPARATION AND APPROVAL OF THE DETAILS AND SHOP ORAY4NGS AND FOR DETERLININO THEIR SUITABILITY FORA PARTICULAR PROJECT OR APPUCATICN. WHILE SMA SARYAFb. PROVIDES GENERAL INSTRUCTIONS FOR TPC INSTALL/MOI: OF ITS MEMBRANE AS WELL AS,IRAININ0 FOR SAGA SARNAF5. AUIIORIZED APPLICATORS. THE MEANS AND METHODS USED BY THE CONTRACTOR FOR SURFACE PREPARATION AS WELL AS THE 1DE ANS ANC METHODS E:: FLOYED By TIE CONTRACTOR W THE INSTALLATION OF TNF SEA SARNAFIL MEMBRANE AR8 DIE RESPONSIBILITY OF THE CONTRACTOR Sika Sarnafil Roofing Specification Manual MULTI—PURPOSE TAPE CONTINUOUS METAL HOOK STRIP (MIN. 22 GAUGE) METAL COPING CAP WITH WATERTIGHT JOINTS SARNAFIL FLASHING TO ACCEPTABLE SUBSTRATE r TREATED WOOD NAILER ti 0 0 0 Typical System Details SECUREMENT FASTENED AT BASE OF WALL OR CURB ALTERNATE BASE_ FASTENING GROMMETTED FASTENER 12 IN. O.C. i ---SPECIFIED SARNAFIL SECUREMENT HOT—AIR WELD SARNAFIL MEMBRANE D STRUCTURAL DECK AIR / VAPOR BARRIER (AS REQUIRED) NOTES: INSULATION SECURELY FASTENED 1) NAILERS SHALL BE SECURELY ANCHORED TO THE DECK TO RESIST A MINIMUM FORCE OF 300 POUNDS PER LINEAR FOOT. REFER TO FACTORY MUTUAL DATA SHEET 1-49. 2) METAL EXTENDER PIECE IS REQUIRED IF EXISTING COUNTERFLASHING IS CONTAMINATED AND OR COUNTERFLASHING FASCIA IS LESS THAN 4 -INCHES WIDE. 3)VAPOR BARRIER SHALL BE SEALED AT EDGES. 4) APPROVED FOR SIKAPLAN AND SIKAPLAN NDL WARRANTIES. PARAPET WALL WITH i •ETAL Sarnafile NAME.JOG • pII,G' ,TAF scALE.N.T.s. I DATE. 1/111 FILE NO 2_3 j oavY roc AB A MOM/ MAMIJPACTERER NRA BAR MAL. A ONION 6 TPK* CORPORATION REviE*S ETAL* PREPARED HY THE CONSULTANT. ARC' TECT AMOK ENTBIEER FOR A Namur May TOR TIE nAwaE a DETEIUOEIR V A ORA 5*C *RE WAR•WRY NAT OEM Pdl TIE PROJECT. HAS REVIEW LS AKT TO BE CONSTRUED AS APPROVAL OE DETAMS BY RNA EAIBMRL NID N NOT BEER CDIEMJL= IN UM OP sot= EMMEN: NG AND ARCHITECTURAL PRACTICES NC AND SHOULD NOT BE RELIED UPON EOR THAT PURPOSE. lAITA CORPORATON ASSUI6E ND LIABLRY WRN RLA1t 0RMO ETBTEN TME M (TELT. CA lLLTANE y�R05 ENOiN5E* OR DEOON PROFE5504j EON A PARTCUAR PR0�EC* HEAR* THE BDIR REBPONBOLNYN j�02 7T47N2E MEMO' TO THE TM ROOFING OR WA BYBTEILFORTIE Pff12PAMTCN M""TtVAL OP THE DETMSANDSNOP DRAINNCS.*303047 OETERLUWNC 104554x-aeNPpRAPARICILAR FYBIEC}OR APRIG710N a TRE TbpPMA QR COAR OMA 1 PREPARATION RE ARATIO L *IETRLATIDNB POR TME D METHODS E OF RS D EM®TANC MT HELL A5 THE WO FON S*V1 F TrIE Sl A4IYH I$D AppIANG TIE L¢MEB AND A `.,�E CONTRACTORFOR 81.20 PRE PARATIONAEWEEI.ABTHE IENI*ANL) METROS EMPLOYED 1PE CONr47 SCR MI THE OI*1ALLATgN OF 1nE 3$*$*ANNE EEIEIRAIEATa TI¢ . TE142115400 elkacorp.ppm 2-12 ED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Sika SarnafA Roofing Specification Manual Typical System Details SARNAFIL MEMBRANE HOT-AIR WELD I SPECIFIED SARNAFIL SECUREMENT TREATED WOOD BLOCKING FOAM ROD TUBING (COMPATIBLE) -- 1 INCH GALVANIZED ANNULAR RING 1 NAILS 4 INCHES O.C., STAGGERED SARNAFIL FLASHING STRIP, HOT-AIR WELDED SARNAFIL FLASHING TO ACCEPTABLE SUBSTRATE INSULATION SECURELY FASTENED -- STRUCTURAL DECK NOTES: BATTEN INSULATION 1)NAILERS SHALL BE SECURELY ANCHORED TO THE DECK TO RESIST A FORCE OF 300 POUNDS PER LINEAL FOOT IN ANY DIRECTION. 2)VAPOR BARRIER SHALL BE SEALED AT EDGES. 3) APPROVED FOR SIKAPLAN AND SIKAPLAN NDL WARRANTIES. AIR / VAPOR BARRIER (AS REQUIRED) NPANSION JOINT ON _CURB WITH F AM R3D s Sarnafil ® 18140S-0400 am001p corn JOB NAME, SCALE N.T.S. DM: 1 /11 FIE NO 4-4 OR W. NO A& A MEIIRANE MANUFACTURER, EON &ARMFL A MOON OF SPA CORPORATOR REVIEYIS DEWS MEPAR D BY THE CONSULTANT, ARCHITECT MOOR ENGINEER FOR A PROJECT =MY FOR THE PURPOSE R DEmm/0SMN6 V A EOM &ARMKL WARMMIY NAY ISLE FOR THE PROSECT TRPS REVMP IE NOT TO 8E CONSTRUED AS APPROVAL OF MULE BY SOFA &ARNAFL N/ IS NOT BEM COIOUCTED IN LEU OP NANO ENGINEERING AMO ARC187[CTIRAL PRACRCE9 AND d8G11SOJ3 AND SNOUL° Not RE RELIED UPON FOR TEAT PURPO8E 8Y(A CORPORA7ON ASSUMES NO LIMSJTY WRM WPM 70 ME MOON Of TNS MOORN° OR WATERPROOFP/0 SYSTEM 711E ARCMTEOT, CONSULTANT MOOR ENGIEEN OR OPSIM44 PROFESSIONAL 0DR A PANT4CIAAR PROJECT BEAM 11{S ROLE RE&Pdg/Nry FOR THE OF4IGN OF THE ROOMS; OR WATERPROOFING SYSTEM FOR ENE PREWAR/WNW NOAPPROVAL OF INE OPINES AND SHOP ORAWiNDS. AND FOR DETERWIENO INEiR 0OTA5L1rY FORA PMOCNAR PROECFOR MPINITION. Yell& 8MM SAMOSA PROFIOSB GENERAL O ERREGTI5IE FOR TME INSTALLATION Or ITS NEARNAN( AS WELL AS TRNNMO TOR SSA SARNAWL ALMIOIIIO APPuCATOR&. TIE ►IAN& ANO /l7 CONNMCTOR 10q MINYA= PREPARATION AS WELL AS WEANS PND AE 1«ODS EMPLOYED EY THE CONTRACTOR IN TME 1NSTALATPON Of THE SBGAEARMNL NEI/RAMS All ME REEppMBRIryOF 2-12 ED CITY OF TUKWILA SEP 3 0 2013 PERMIT VENTER Sika Sarnafil Roofing Specification Manual NON—REMOVABLE UNIT Typical System Details GROMMETTED FASTENER 12 INCHES O.C. - METAL EXTENDER PIECE WITH SIKAFLEX-1A SEALANT ONTO BACK SIDE SARNAFIL FLASHING TO ACCEPTABLE SUBSTRATE — — SPECIFIED SARNAFIL SECUREMENT i HOT—AIR WELD SARNAFIL MEMBRANE STRUCTURAL DECK NOTES: L -- AIR / VAPOR BARRIERAS REQUIRED) SQUIRED) 1) METAL EXTENDER PIECE IS REQUIRED IF EXISTING COUNTERFLASHING IS CONTAMINATED AND OR COUNTERFLASHING FASCIA IS LESS THAN 4 INCHES WIDE. FASTENED 12 INCHES O.C. WITH GROMMETTED FASTENER. 2) VAPOR BARRIER SHALL BE SEALED AT EDGES. 3) APPROVED FOR SIKAPLAN AND SIKAPLAN NDL WARRANTIES. 1 - INSULATION SECURELY FASTENED NON -REMOVABLE__ ic_ORQ_ELFLASHING Sarnafil® .Re NAME. 1 DATE 1/11 1 FRE NO: 5-2 1 MEN. NO AS A 141WU/TF 1MNWACTILER, SKR BARNAFL. A a1Yt6ml OF 871A CORPORATION REVEWS DEE/AS PREPARED BY THE CONSIATANT. ARCNRECT ARDOR ENfDIEEA FOR A ARLEDT BaSLY IDR TRE P1IRFOEE a DETERNDEND IF A MRA SLNAqONIAA{{RD WARRANTY WY 18911 FOR IRE PROJECT TIS REWEW IS NOT I0 8E CONSTRUED AS APPROVAL Of Mate BY SRA BMNAFIL AND 10I T p[8ED END11fERIND NO AMMil. PRADTE A5 AND JYp0RENT AND SNOIAD NOT OE REUED UPON TDR THAT PURPOSE SNA CORPORANON ASSURER NO IARIERY WRN NEW= ROTACONDuCTED IN MUS CO RRO SO OAR WATERPROOF/1G SYSTEM MA ARDRITECT_ CON94TANT ARDOR ENGINEER OR DESIGN PROFESSOR./ FOR A PARTOIAJA PROJEOI BEARS TIE EDL( RESPON9ELJ1Y FOR THE DE9GN Or T �NNNNOODD DDO0pppp Pima WA SAIMAA. PROVIOP-11 GENERAL WATERPROOFYFO BYBEE* FOR ENE PREPN4ARONAND APgpVAL OF THE DETAUS AND DROP fRtAWMGS. AND FOR DEMO/ADO TRIM BU�tABRITY FORA PARTTCILAR PROECTORAPR-CATIONCONTRACTOR FOR RIAF PREPARATION AS W �M WEANS AND moms EUPLDNEDBT CONTRACIDR W THE INSTALLATIONOE�1.A SSOCA� D AWRAME RE. TIE SPARS µp RETNDDB BIIyL1FL IERBfiA1E ARE THE RaFVLseLlrraPTle 2-12 1st.8?8-s4DD ebscorp can N.T.S. La I Trap EIVED TUKWILA SEP 3 0 2013 PERIVNit CENTER Sika Sarnafil Roofing Specification Manual Typical System Details 8 INCHES MIN 1 z .Q NOLE: 1) METAL EXTENDER PIECE IS REOUIRED IF EXISTING COUNTERFLASHING I5 CONTAMINATED AND OR COUNTERFLASHING FASCIA IS LESS THAN 4 INCHES WIDE. FASTENED 12 INCHES O.C. WITH GROMMETTED FASTENER. 2) VAPOR BARRIER SHALL BE SEALED AT EDGES. 3) APPROVED FOR SIKAPLAN AND SIKAPLAN NDL WARRANTIES. y 0 v --- SELF -FLASHING UNIT — ADDITIONAL WOOD BLOCKING, IF REQUIRED (TO ACHIEVE AN 8 IN. MIN. FLASHING HEIGHT) - GROMMETTED FASTENER 12 INCHES O.C. M n ) — SARNAFIL FLASHING TO ACCEPTABLE SUBSTRATE SPECIFIED SARNAFIL SECUREMENT — HOT-AIR WELD SARNAFIL MEMBRANE STRUCTURAL DECK 1 --- INSULATION SECURELY FASTENED L AIR / VAPOR BARRIER (AS REQUIRED) kr_mov;4E LE CUR13 F Sarnafil® 761.7-5400 ELbJDD(p DDR, JOS NAME. SCALE N.T.S. 00.7E 1 /11 FILE NO 5-1 ORW NC AS A IR4gFWTE 14WIFACTLP1P. sio &v w.. A DARR**. O sIIA CORPORATOR REVIEWS DETAES PREPARED BY THE COfOLITANT. ARCISTEC MOOR IDEEIR FOR A PROJECT 'IORLLY''OR THE PURPOSE CP D!i[IDWLHO IP A MCA IATDRARL WARMNTY MAY ISSUE FOR T,e PROJECT THS REVIEW LS NOT TO BE CORS1 RUED AS APPRWAL OP DETA6S IV IDUR PROWL AHD III NOT .[DIC CC CUCT[D U4 MU OP ECRPD EMOIEVOND AND ARLIEIECTIRML PRACTICED AND JUDGMENT AND WOULD NOT BE RELIED UPON FOR THAT PURPOSE. SDN COR ORATION ALIUIES NO WOWTY PMMO CT TO OTE' OMR OF THE Row oleo OR WATERPROORNB SgTEM TT ARCMTWT. CONSULTANT MOOR ENCNEER Oq DEVON PROFEBEINEL FOR A PAR'NCUWI PRDECT awe THE SOIL RESPONSIELRY FOR UNE 0.1&ON OF TK RDDFW5 OR WATERPROOFING SYSTEM, FOR TFE PItEPARATOTN ANDAPPROVAL of TUR DEYAAEAND SHOP CRAwMGsARO DOA SEMOANING NPR STIITAmUTY FORA PARTICULAR PRQIECT OR APPLICATION WNLE PEA SARNAPL PROMPT DEIO;RAL INSTRUCTiONP FOR THE INSTALLATION OF RS MEMBRANE AS WEU AS TRNNWO FOR LIRA SAW WL WHORL= APPJGTOO.�� TME CONTRACTOR FOR SWAM PREPARATION AEI WELL AS RHE LIMNS AND STEEIAOS EMPLOYED EY THE COARRACTOR II THE INSTALLATION(' TIE IkAINA ARFI MEIOIA1E ARE THE R7R 2-12 CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTei1 Sika Sarnafi! Rooflno Specification Manual Topical System Details r- PIPE PENETRATION SIKAFLEX-1A SEALANT (SEE NOTE) STAINLESS STEEL HOSE CLAMP — SARNAFIL FLASHING MEMBRANE r-- SARNAFASTENER AND 1 SARNADISC SARNAFIL BASE FLASHING. HOT-AIR WELDED SARNAFIL MEMBRANE STRUCTURAL DECK — MR / VAPOR NOTE: 1) SEALANT IS A MAINTENANCE ITEM. MAINTENANCE IS NOT COVERED UNDER SARNAFIL WARRANTY. 2) VAPOR BARRIER SHALL BE SEALED AT EDGES. 3) APPROVED FOR SIKAPLAN AND SIKAPLAN NDL WARRANTIES. INSULATION FASTENED SECURELY BARRIER (AS REQUIRED) cot; FLASHIN ,�-r- F``; JET I(J. Sarnafi/® 11114 1284400 *man cam JOB NAME 5CMEN.T.S. DATE 1 /11 FILE NO 7-3 ORW NO AB A JNJNRATN NANDACIIAZER. SORA 6ARIMFR A ONIFON Or NM CORPORATION REMEWS DETALB PRE PARED BY THE oONNFLTANT ARCIBTECT Nom BNCIKER FOR A PIpJECT S4ELY FEF THE PIW E OF OE7ERYDINO UP A BCA BARB", WARRANTY MAY ISSUE FOR TE PROJECT TMS RE REW ES NOT 10 BE CONSTRUED AS APPROVAL OF DETAILS BY BIG SWAM Alm N NOT MEMO COIOUCTIb IN LEU OF SOVO ENGINEER= ANO ARCIREGREEPL PRAM= ANO JUDOMENI AND 311OUL0 NOT SE RELIED WV.. FOR 7/FAT PURPOSE SiNA CCBOIOMTOIT manage ND UEBBJTY WIT$ REBFLCT TO TNB wow O TK 000p400 OR WATNRPROOPBO SYSTEM TIN PPOSTECT, CONSUEIANT ARDOR ENGINEER OR OLSON PROFESSON& FOR A PARrc E q PILOJECT BURS THE BOLE RESPOFENRILITY FOR TIE DESIGN OF TNN ROOFING OR WAIERPROOFBm BYBTEN FOR THE PREPARATION AND APPROVAL OF THE CRT/RI-SANS SPOP °RADA. CE. AND FOR DE TERIANiNC TIEN SUITABILITY FORA PARTICULAR PROJECTOR IRE= BOLA MAW% =NOES OBIERAL BOTRUCE ONS FOR TME INSIALIATION OF FM MEMBRANE AS WELL AS IRNWNO FOR BENE BANJAFL AUTHORING APIWATORS TIN "•I t _ IA. CONTRACTOR FORSURFACEPREPARATICRI SWELL AS THE MEANS AND NETAOOS EFAILOTED OV FRI-CONTRACTOR Ih IRE =IM AGM OP THE BNA&UWAFB MIAIIIRAFIEA16 THE 2-12 CITY Oh IUKviILA SEP 302013 PERMIT CENIIR Sika Samafil Roofing Specification Manual Typical System Details 8 INCHES MI - - PIPE PENETRATION SIKAFLEX - SA SEALANT (SEE NOTE) STAINLESS STEEL HOSE CLAMP ALUMINUM TAPE (SEE NOTE) -SARNAFIL FLASHING MEMBRANE SARNAFASTENER AND SARNADISC - - SARNAFIL BASE FLASHING, -SARNAFIL MEMBRANE STRUCTURAL DECK - INSULATION SECURELY FASTENED NOTES: - AIR / VAPOR BARRIER (AS REQUIRED) 1) ALUMINUM TAPE IS REQUIRED IF EXISTING PENETRATION IS CONTAMINATED. 2) SEALANT IS A MAINTENANCE ITEM, MAINTENANCE IS NOT COVERED UNDER THE SARNAFIL WARRANTY. 3) VAPOR BARRIER SHALL BE SEALED AT EDGES. 1 uP = PENET 4 TIC'N _FLA1[1H Sarnafil® 7014265400 alksa 1p.Ogr JOB NAME: SCALE'N.T.S. GATE, 1 /11 FILE NO, 7-2 ORW NO AS A EEIESRARE NARRALTLRtER AKA 011R74MQ A DIVISION OF Sn1A COmORATIDN RCvIEWS DE-TAAS PREPARED Br THE CCNSUL.TANT ARCHITECT MOM ENGINEER FON A PROJECT SOLELY FOR 7NL PURPOSE OF DETERYMENO F A Om BANWIEIL "MOUNTS NAY LSSuE FOR TRC PROJECT THL9 'UMW IS NOT TO BE CONSTRUED AB APPRSYAL I Mums BY mu SARM{ L NO IS NOT DEMO COAOTJCTEO IN UEJU1 pOpPA ISNOeIAID EMMEERWO AND ARCJETECTEIGL FNAC}ICBA AND JUOGNENT AND SIAM D NOT BE RELIED LPO: FOR THAT PURPOSE SBA CORPORATIONROUSED NO 6JASIUTY VAIN RESPECT TO THE OECr JRLIEV'L:l WATIRFIOOPING AMEN TNS ARCNTECT CONSIATANT ANOOR ENOINE ER OR DESIGN PROFESSIONAL fCR A PARTICAAR PROJECT SEARS nit SOLE RLLFO LOY EOR 1) DESIGN 1g1LEHt. `SE3O'fi`IWI WATEMGOPDIO SYSTEM, FOR THE PREPARATION ANO APPROVAL Of INT DETAUS AND SHOP DRAHTNCS,AND FON DETERS/007C THOR OWCRIgJTY FORA PARTICULAR FRpiCT OR APEEICATM R MILL SMA tARNAFt PROVIDED GENERAL DESTRUCTIONS FOR THE INSTALLATION of ITS MEMBRANE AS WELL AS T/WNMC FOR SSA SARNAFIL AJTNO OSO APPLICATORS.� 44 NEAR AND y TF O C 7RICTOR FOR LUWACL PREPAATONAS Rut. As THE MEANS AND IETHOOS EMPLOYED BY THE CONTRACTOR NTH61N8TN WWI [OMR MADADWL MPMm RES` V�>cATL LN�9 2-12 D WILA SEP 302013 PERMIT CJJTER Wayne's Roofing, Inc. 13105 Houston Road Scanner, WA 98390 www.wavnesrooflng.com PRODUCT DATA 2 RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Product Data Sheet Edition: 09/2012 Version no.: 0001 Sarnatherm Roof Board -H Overview: Samatherm Roof Board -H is a lightweight, high-density polyisocyanurate roof board for new, re-cover and re -roof applications. The coated fiber glass facers provide strong, smooth surfaces suitable for mechanically at- tached or fully adhered membranes. Composition: Samatherrn Roof Board -H is high-density polyisocyanurate with fiber glass - reinforced facers. Samatherm Roof Board -H is provided in a 4 ft. x 8 ft. (1.2 m x 2.4 m) board size and in a thickness of 1/2 inch (13 mm). Features: • Lightweight for easy hoisting, staging and maneuvering • High impact and flexural strength • Improved resistance to foot traffic and normal roof maintenance • Low water absorption • Easy scoring, cutting and snapping • UL Classified 790 • FM Approved (consult RoofNav for specific assemblies) Packaging: Samatherrn Roof Board -H is packaged 96 pieces per bundle. Weight per sheet Is 11 lbs. (4.9 kg). Protect Samatherrn Roof Board -H from damage and moisture during transportation and storage. Installation: Samatherm Roof Board -H is installed by a Sika Samafil Authorized Ap- plicator by mechanical -attachment to the roof deck with approved fasteners and plates. Attachment with specialized adhesive(s), options dependent on deck type and Sika Samafil system to be installed. Maximize board lengths to minimize end joints with end joints staggered. Drive fasteners firmly against and flush with surface of Samatherm Roof Board -H. Samatherrn Roof Board -H is cut by scoring and breaking. Do not install more Sarno - therm Roof Board -H than can be covered with welded Samafil membrane in that day. Availability: Samatherm Roof Board -H is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Samafil Roof System. Contact your Sika Samafil Regional Office or visit our website for further information. Warranty: As a Sika Samafil supplied accessory, Samatherm Roof Board -H is in- duded in Sika Samafil's System Warranty to the Building Owner. RECEIVED CITY OF TUKWILA SEP 3 0 2013 Sarnafil® PERMIT CENTER E Maintenance: Samatherm Roof Board -H requires no maintenance. Technical: Sike Samafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation methods of Sarnatherm Roof Board -H, Technical Data (as manufactured): Prone v Test Method Thickness, nominal Width, standard Length, standard Pieces per pallet Weight per sheet (4x8 sheet) Dimensional Stability ASTM D 2126 R° Value ASTM C 518 WaterAbsorption, % max ASTM C 209 Compressive Strength, ASTM D1621 Mold Resistance ASTM D3273 Service Temperature Recycled Content Flame Classification 13 mm 4' (1220 mm) 8' (2440 mm) 96 11 ib. <0.5% (linear change 7 days) 2.5 <1% Volume >1DOpsi Passed (10) 260 For less >8% FM Approved (consutt RoofNav for specific assemblies) UL Classified 790 Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: webmaster.samafil@us.sika.com RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Canada Office Sika Samafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: Ag information provided by Sika Corporation (3ike7 concerning Sika products, including but not united to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Stke's current experience and knowledge of its products when property stored. handled and applied under normal condttons in accordance with Stka's instructions. in practice, the Mumma rn matenals substrates storage and handling conditions. actual site conditions and other factors outside o! Sike's control am such that Sika assumes no liability for The provision of such information. advice, recommendations or instructions related to ifs products, nor shall any legal relationship be created by or rinse from the provision of such information. advice, recommendations orinstructions related to lis products. The user of the Sika products) must lest fire producl(s) for suitability for the intended application and purpose before proceeding with the furl application of the product(s). Slke reserves the right to change the properties of its products without notice. All sales of Sika product(s) ate subject to Oa cunni terms and conditions of sale which are available et usa samahl sika, com or by calling 800-451-2504. Pnorto each use of any Srka product the usermust always read and follow the warnings and instructions on the product's most current Technical Data Sheet. product label and Merenal Safety Data Sheet which are available at usa.samefii sika com or by contacting 800.451-2500, ,Notting contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Stka product as set forth in the current Technical Data Sheet. product label and Matena! Safety Date Sheet pnor to product use. Product Data Sheet Edition: 5/2007 Version no.: 0004 Sarnafastener - XP Overview: Samafastener-XP is a specially -designed fastener used with Samadisc, Sarnadisc-XPN, Samarail or Sarnabar to attach the Samafil S327 roof membrane directly to (16 - 24 gauge) steel roof decks, approved structural concrete or wood roof decks greater than 15/32 inch and structural con- crete decks. Composition: Samafastener-XP is made from carbon steel, treated with a corrosion resistant coating to meet the Factory Mutual 4470 criteria for corrosion resistance. Features: Samafastener-XP has an enhanced buttress thread to increase both surface area and friction against the deck for improved backout resistance and exceptionally high pullout values. The shank diameter is approximately 0.21 inch (5.3 mm) and the thread diameter is approximately 0.26 inch (8.6 mm). The driving head has a diameter of approximately 0.435 inch (11 mm) and is #3 Phillips design for positive engagement and simplicity of ap- plication. The thread density is 13 lumslinch (approximately 5 tums/cm). Packaging: Samafastener-XP is packaged in boxes or plastic buckets in quantities of 250, 500 or 1000. See Technical Data section for lengths and weights. Installation: Availability: For S327 roof membrane attachment, the Samafastener-XP is placed through the Samadisc, Samadisc-XPN, Samarail or Samabar, through the membrane, insulation and set into the roof deck with a heavy -duly (4 amp min.), variable speed (0-2500 rpm), reversible saewgun with clutch release and a #3 Phillips drive bit. Samafastener-XP must penetrate steel, wooden plank and concrete roof decks 1 inch (25mm) and the underside of plywood roof decks % inch (13mm). Pre -drilla 7132" ANSI pilot hole when installing in structural concrete decks using a hammer or rotary hammer drill. Hole shall be 1/2" deeper than required embedment for concrete decks. Care must be taken to not damage the roof deck. Choose the correct fastener length and do not overdrive or underdrive the Samafastener-XP. Pullout tests may be required prior to job start. Contact Sika Samafrl's Technical Department for determination. Samafastener-XP is available directly from Sika Semen' Authorized Ap- plicators when used within a Sika Samafil roof system. Contact your Sika Samafil Regional Office or visit our website for further information. RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Sarnafil® Warranty: As a Sika Sarnafil-supplied accessory, Samafastener-XP is included in Sika Sarnafirs Standard or System Warranty to the Building Owner. Maintenance: Sarnafastener-XP requires no maintenance. Technical: Sika Samafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method of Samafastener-XP. Technical Data: Loth Thread packaging WIjg! 1-% inch 1 inch 1000/Bucket 12 Ib (32 mm) (5.4 kg) 2 inch 4 inch (101 mm) 5 inch (127 mm) 6 inch (152 mm) 7 inch (178 mm) 8 inch (203 mm) '10 inch (254 mm) '12 inch (304 mm) '14 inch (356 mm) '16 inch (406 mm) 1-% inch 1000/Bucket 19 Ib (8.6 kg) 2-% inch 1000/Bucket 29 Ib (13.2 kg) 2-% inch 1000/Bucket 38 Ib (17.2 kg) 3-% inch 1000/Bucket 47 Ib (21.3 kg) 3-% inch 500/Bucket 29 Ib (13.1 kg) 3' inch 500/Bucket 33 Ib (15.0 kg) 3-% inch 500/Bucket 37 Ib (16.8 kg) 3-% inch 500/Box 46 Ib (20.9 kg) 3-% inch 500/Box 55 Ib (24.9 kg) 3'h inch 500/Box 65 Ib (29.4 kg) 3-% inch 250/Box 38 Ib (17.2 kg) 'Maybe coated with a grey corrosion resistant coating Corporate Office Sika Sarnafil Inc. 100 Dan Road Canton, MA02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: www.sikacorp.com Email: webmastersamafil@us.sika.com Disclaimer The information, and, in particular, the recommendation relating to the application and end-use of Sika Sarnafil products.' em given in gopd faith based on Sika Samafil's current knowledge end experience of the products when property stored. handled and applied under normal conditions in accordance with Sike Same! recommendations In practice. the differences in materials, substrates and actual Me cvntfbons are such that no war- ranty In respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application end purpose Sika Same! reserves the nght to change the properties of its products The proprietary nghts of Ihird parties must be observed. All orders are accepted subject to our current terms of sale and delivery, Users must ahveys refer to the most recent issue of the local product Data Sheet for the product concerned, copies of which will be supplied on request RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTFR Canada Office Sika Samafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5276 Web: wwwsika.ca Product Data Sheet Edition: 3/2008 Version no.: 0001 Sarnadisc RhinoBond Overview: Samadisc RhinoBond is a specially designed, polymer coated plate used with Samafasteners to attach insulation or cover boards directly to the roof deck or structural purlins prior to the installation of the Sika Samafil membrane. The membrane will be welded to the Samadisc RhinoBond by induction welding. Composition: Samadisc RhinoBond is a 3 inch (75 mm) diameter, 0.028 inch (0.7 mm) thick metal plate with a polymer coating, meeting the Factory Mutual 4470 criteria for corrosion resistance. Features: Sarnadisc RhinoBond has a recessed center to provide protection to the membrane underside from abrasion by the fastener head. Packaging: Sarnadisc RhinoBond is packaged in Pails of 500. Each pail weighs ap- proximately 54 lbs (24 kg). Installation: Sarnadisc RhinoBond is positioned on the surface of the insulation board. A Sarnafastener is set through the center of the disc and set into the roof deck or purtin. The Samadisc RhinoBond holds the insulation in place. Availability: Samadisc RhinoBond is available directly from Sika Samafil Authorized Applicators when used within a Sika Samafil roof system. Contact your Sika Samafil Regional Office or visit our website for further information. Warranty: As a Sika Samafil supplied accessory, Samadisc RhinoBond is included in Sika Samafil's Standard or System Warranty to the Building Owner. RECEIVED CITY OF TUKWILA SEP 302013 PERMIT CENTER Sarnafil® Maintenance: Sarnadisc RhinoBond requires no maintenance. Technical: Sika Samafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method. RECEIVED CITY OF TUKWILA SEP 302013 PERMIT CENTER Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: www.sikacorp.com Email: webmaster.samafill@us.sika.com Canada Office Sika Samafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON 1.5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: www.sika.ca Disclaimer. The information. andin particular the recommendation relating to the application and end-use of Ma Samafil products. are given in good faith based on Sika Semeal's current knowledge and experience of the products when properly stored, handled and applied under normal condtions in accordance with Slke Samehf recommendations In practice, the differences in matenals, substrates and actual site conations are such that no war- ranty in respect of merchantability of fitness for particular purpose, nor any liability arising out of any legal relationship whatsoever, may be Inferred from this Information. The user of the product must detemmne the product's suitability for the intended applrcabon and purpose Sike Samafil reserves the right to change the properties of its products The proprietary rights of thud parties must be observed All orders are accepted subject to our currant terms of sale and delivery. Users must always refer to the most recent issue of the local product Data Sheet for the product concerned, copies of which wii be supplied on request Product Data Sheet Edition: 04/2013 Version no.: 0002 Sarnastack Universal Overview: Samastack Universal is a 60 mil (1.5 mm) thick prefabricated stack/pipe boot used as a time -saving and attractive part of a Sika Samafil roofing system. Samastack Universal comes in EnergySmart White, Tan and Light Gray. Composition: Samastack Universal is injection molded with the same time -proven formu- lation used in our Samafil membranes. Features: Samastack Universal simplifes the flashing procedures for stack/pipe details reducing the risk of leakage. They are available in one size which accomodates stack/pipe penetrations from 3/4" - 8° (19mm-203mm) in diameter. Samastadc Universal is heat -welded in place, becoming an inte- gral part of the Sika Samafil roofing system. Packaging: Samastack Universal is packaged in boxes of 8 pieces and comes with custom made stainless steel clamps. Each box weighs a total of 30 lbs (13.6 kg). Installation: Samastadc Universal's lower flange is heat welded in place with a hand- held hot-air welder and roller. The top is then clamped to the staddpipe using the damp provided. Slkaflex la is then used to caulk around the top. Availability: Warranty: Samastack Universal is available directly from Sika Samafil Authorized Applicators when used within a Sika Samafil Roofing or Waterproofing System. As a Sika Samafil supplied accessory, Samastack Universal is induded in Sika Samafil's Standard or System Warranty. RECEIVED CITY OF TUKWILA SEP ' 3 0 2093 PERMIT CENTER Samafile Maintenance: Samastack Universal requires no maintenance. Periodic maintenance of a Sika Samafil system ensures extended performance and reduces life cycle costs. Consistent with industry practices, Sika Samafbl recommends in- specting the roof system for damage, plugged drains, weathered sealants, etc. at least twice a year and after each storm. Technical: Sika Samafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. RECEIVED CITY OF TUKWILA SEP 302013 PERMIT CENTER Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: webrnaster.samafil@us.sika.com Canada Office Sika Samafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1 L5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer. Al information provided by Sara Corporation (-Sika, concerning Sika products, including but not limited to. any recommendations and edvtce relating to the ap*ation and use of Sika products, is liven in good faith based on Sika's currant expenence and when property stored, handled end applied under normal conditions in secordence with Sika's instructions In of its products substrates, storagepractice, tat Sika assumnesses in omkabi ls. end handling conditions. ettu8! site conditions and other /actors outside of Sika's control are such that Sika assumes no habiGty for the provrson of such information. advice, recommendations orinstructions related to its products. nor ahatl any legal relationship be created by or Wise horn the provision of such Information• advice, recommendations orinsbucbons related to rfs products. The user of the Sika product(s) must test the product(s) for suitability forte intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. Alt reales of Slice product(s) are subject forts cunent terns end oondtions of sale which ere available et usa.samafl.sike.eom or by calling 800.451-2504. Prior to each use deny Sika product, the usermust always read and follow the warnings and instructions on the product's most current Technical Date Sheet product label and Material Safety Data Sheet which ere available at usasamahl srke.com or by contacting 800-451-2504. Notting contained in any Slka materiels relieves the user of the obligation to read and follow the warnings and instruction for each Sika product es set forth in the current Technical Data Sheet, product label end Material Safety Data Sheet prior to product use. Product Data Sheet Edition: 2/2013 Version no.: 0007 Sarnaclad /PO 'a% A-?ro CA - - L Overview: Samadad is a heat -weldable flashing product used with Samafil G and S membranes to form a monolithic roofing or waterproofing system. Composition: Samadad is a 24 gauge, G90 galvanized metal sheet with a 20 mil (0.5 mm) unsupported Samafil membrane laminated on one side. Samadad is available in seven standard colors. Standard colors are Copper Brown, White, Evergreen, Lead Gray, Light Gray, Patina Green, and Tan. Sika Sar - naffs Energy Star rated EnergySmart Roof® color family consists of White. Tan, Light Gray, and Patina Green. The dimensions of Samaclad are 4 ft x 8 ft (1.2 m x 2.4 m) or 4 ft x 10 ft (1.2 m x 3.0 m). Recycled Content (metal): 25% Post Consumer, 6% Pre Consumer Recyded Content (membrane): 0% Features: Samadad is a durable and attractive flashing product capable of being formed into a large variety of shapes and profiles. Heat -welding of Sar- nafil G and S membranes to Samadad assures watertight integrity. The Sarnadad has a unique lacquer coating to resist staining from airborne dirt and pollutants. Packaging: See Technical Data section for information. Installation: Samadad is cut to size and formed to shape on standard sheet metal equipment. Samadad is fastened in position in accordance with Sika Sar- nafil Technical requirements. The Samadad joints are covered by 2 inch (50 mm) wide aluminum foil tape and then made watertight by heat -weld- ing a 4 inch (100 mm) wide G410 membrane strip over the tape. By use of a Samafil G or S coverstrip, the roofing or waterproofing membrane is then heat -welded to the Samaclad. Availability: Samadad is available directly from Sika Samafil Authorized Applicators when used within a Sika Samafil roofing or waterproofing system. Contact your Sika Samafil Regional Office or visit our website for further informa- tion. Warranty: As a Sika Samafil-supplied accessory, Samadad is included in Sika Samafil's Standard or System Warranty to the Building Owner. RECEIVED CITY OF TUKWILA SEP 3 0 2093 Sarnafil® PERMIT CENTER Maintenance: Samadad requires no maintenance. Technical Data: Sika Samafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method of Samadad. Sheets/Pallet Size 25 4ftx8ft (1.2mx2.4m) Weiaht/Sheet Weiahtlpallet 35 lbs (16 kg) 905 lbs (410.5 kg) 25 4ftx10ft 44lbs (20kg) 1,130lbs (512.6kg) (1.2mx3.Om) Recycled Content (metal). 25% Post Consumer, 6% Pre Consumer Recycled Content (membrane): 0% RECEIVED CITY OF TUKWILA SEP 3 0 2093 PERMIT CENTER Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: webmaster.samafil@us.sika.com Canada Office Sika Samafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1LS Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer. All information provided by Sika Corporation ('Sika) concerning Sika products, including but not limited to. any racommendabons end advice relating to the application end use of Sike products, is given In good faith based on Sika's current experience and knowledge of ds products when properly stored, handled and applied under normal conditions in accordance with Vat's mstuclrons In practice, the differences in materials. substrates, storage and handling conditions, actual site conditrons and other factors outside of Sikka's control are such that Sika assumes no babtbty for the provision of such information. advice, recommendations or instructions related to its products. nor shell any legal relabonshrp be created by or arise from the povrsan of such information, advice, recommendations orinstructlons related to its products, The user of the Sika product(s) must test the produd(s) for suitability for the intended appbcation end purpose before proceeding with the fab application of the product(s). Sika reserves the nght to change the properties of its products 'Wheat notice. All sales of Sika produd(s) am subject to ifs current terms and conditions of sale which aro available at usa. samaft srka,com or by catling 800-451.2504. Prior to each use of any Sika product, the usermust always read end follow the warnings and instructions on the product's most current Technical Dale Sheet. product label end Material Safety Data Sheet which are available al usa.samafil sika.cam or by contacting 800451.2504 Nothing contained in any Sika matgrials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Matenal Safety Date Sheet poor to product use. Product Data Shoot Edition: 04/2013 Version no: 0015 Sarnacol® 2170 Adhesive Overview: Samacol® 2170 is a solvent -based reactivating adhesive used with a Sika Samafil Adhered system and/or flashing detail. It is also used to adhere flash- ings in Samafil waterproofing systems. It is formulated for adhering Samafil PVC membranes to properly prepared substrates such as wood, sheet steel, masonry, concrete and approved coverboards. Composition: See Material Safety Data Sheet for information. VOC Content: 694.2 g/L Features: Samacol 2170 is uniquely formulated to be compatible with Samafit membranes. Packaging: Samacol 2170 is supplied in 5 gal (18.9 L) steel containers weighing 45 lbs (20.4 kg). The shelf life is 12 months in a tighly dosed container in tempera- tures between -4°F (-20°C) and 86°F (30°C). Installation: Bareback Samacol 2170 is roller -applied to both the membrane and substrate in the fol- lowing manner. Apply Sarnacol 2170 to the substrate and allow to dry. After the substrate adhesive has dried completely, apply Samacol 2170 to the back side of the membrane, and allow to become tacky (producing strings) when touched with a dry finger. The Samacol 2170 on the membrane shall not be permitted to dry completely. The membrane is then placed on the substrate (mating adhesive surfaces). The bonded sheet shall be pressed firmly in place with a minimum 100 Ib (45 kg) steel, membrane roller, by rolling in two directions (vertical flashings are hand -rolled). Fettback: Samacol 2170 is roller -applied to the substrate and allowed to dry completely. A second coat of adhesive is then applied to the substrate. The second coat of adhesive shall not be permitted to dry completely. The membrane is then placed on the substrate while the adhesive is still wet. The bonded sheet shall be pressed firmly in place with a minimum 100 Ib (45 kg) steel, membrane roller, by rolling in two directions. Availability: Samacol 2170 is available directly from Sika Samafil Authorized Applicators when used within a Sika Samafil Roofing or Waterproofing System. Contact Sika Samafil or visit our website www.sikacorp.com for further information. Warranty: As a Sika Samafil-supplied accessory, Samacol 2170 is included in Sika Samaftis Standard or System Warranty. Maintenance: Samacol 2170 requires no maintenance. Technical: Sika Sarnafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. RECEIVED (CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Samafil® Technical Data: Substrate Isocyanurate Organic Facer Isocyanurate Glass Facer Smooth Plywood Metal Concrete Wall DensDeck® DensDeck Prime® DensDeck® Duraguard Securocke Gypsum Fiber Total Rate for Bareback Membrane 1-% gallons per square (0.71 liters/meter') 1-1/2 gallons per square (0,61 liters/meter") 1-1/2 gallons per square (0.61 liters/meter') 1-'/. gallons per square (0.51 liters/meter") 1-% gallons per square (0.71 liters/meter') 1-% gallons per square (0.71 liters/meter') 1-% gallons per square (0.61 liters/meter") 1-% gallons per square (0.61 liters/meter') 1--'/, gallons per square (0.51 liters/meter") Substrate Isocyanurate Organic Facer Isocyanurate Glass Facer Smooth Plywood Metal Concrete Deck Concrete Wall Masonry Wall Cellular Concrete (feltback membrane only) DensDeck® DensDeck Prime® DensDeck Duraguard® Securodke Gypsum Fiber Total Rate for Feltback Membrane 2-% gallons per square (0.92 liters/meter') 2 gallons per square (0.81 liters/meter') 2 gallons per square (0.81 liters/meter') 1-% gallons per square (0.71 liters/meter") 2-% gallons per square (0.92 liters/meter') 2-% gallons per square (0.92 liters/meter") 2-% gallons per square (0.92 liters/meter") 2-% gallons per square (0.0.92 liters/meter') 2-% gallons per square (0.92 liters/meter') 2 gallons per square (0.81 liters/meter') 2 gallons per square (0.81 liters/meter') 1-% gallons per square (0.71 liters/meter') Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: RECEIVED CIITV OF TUKWILA SEP 3 0 202 PEWIT CENTER webmastersamafit@us.sika.com Canada Office Sika Samafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1 L5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: The information. and in particular the recommendation relating to the application and end•use of Sike Samafil prodects. ere given in good faith based an Sika Samahls current knowledge and experience of the products when properly stored. handled and applied undernormal conditions in accordance with Sika Samafil recommendations In practice. Me differences in matenals, substrates end actual site conctlions ere such that no war- ranty In respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this Information. The user of the product must detemnne the products suitability for the intended application end purpose Sika Samafil reserves the right to change the properties of its products. The propnetary nghts of third panes must be observed. All orders am accepted subject to our current terms of sale and deliver. Users must always refer to the most recent issue of the local Product Date Sheet for the product concerned, copies of which will be supplied on request. 1 Product Data Shoot I Edition: 10/2011 Version no.: 0001 Sarnacorners - inside Overview: Samacomers - Inside are a 60 mil (1.5 mm) thick prefabricated comer used as a time -saving and attractive part of a wall flashing detail. Samacomers - inside come in EnergySmart white. Composition: Samacomers - Inside are injection molded with the same time -proven for- mulation used in our Samafil membranes. Features: Samacomers - Inside simplify the flashing procedures for inside comer details reducing the risk of leakage. They are available in one size which accomodates most inside comers. Samacorners - Inside are heat -welded in place, becoming an integral part of the flashing assembly. Packaging: Samacomers - Inside are packaged in boxes of 10 pieces. Each box weighs a total of 30 lbs (13.6 kg) Installation: Ager the wall flashings are installed, Samacorners - Inside are heat welded in place with a hand-held hot-air welder and roller. No caulking or sealants are necessary. Availability: Warranty: Samacomers - inside are available directly from Sika Samafil Authorized Applicators when used within a Sika Samafil Roofing or Waterproofing System. As a Sika Samafil supplied accessory, Samacomers - Inside are included in Sika Samafil's Standard or System Warranty. RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Sarnafil® Maintenance: Sarnacomers - Inside require no maintenance. Periodic maintenance of a Sika Samafil system ensures extended performance and reduces life cycle costs. Consistent with industry practices, Sika Samafil recommends in- specting the roof system for damage, plugged drains, weathered sealants, etc. at least twice a year and after each storm. Technical: Sika Samafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: webmaster.samafil@us.sika.com RECEIVED CITY OF TUKWILA SEP 302013 PERMIT CENTER Canada Office Sika Samafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1 J5 Tel: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer. The information, and in particular. the recommendation relating to the appftcahon and end-use of Sika Sametii products: ale givenfn good faith based an Sika Samafi's cunni knowledge end experience of the products when properly stored. handled and applied under normal cantbhons m accordance with Sika Samafil mcommendeborrs. In practice. the differences in materials. substrates end actual sie cono?b ons ere such that no war- ranty In respect of merchantability 01 fitness fore particular purpose, nor anytiabitity arising our of any legal relationship whatsoever, may be Inferred from this information. The user of the product must determine the product's sunability for the intended application and purpose Siva Samafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed, AN aiders are accepted subject to our Domini terms of sale and delivery. Users must always refer to the most recent issue of the local %dud Data Sheet for the product concerned, copies of which will be supplied on request. Product Data Sheet Edition: 10/2011 Version no.: 0001 Sarnacorners - Outside Overview: • • :1 J. Sarnacomers - Outside are a 60 mil (1.5 mm) thick prefabricated corner used as a time -saving and attractive part of curb and wall flashing details. Samacomers - Outside are available in EnergySmart white. Composition: Sarnacomers — Outside are injection molded with the same time -proven formulation used in Samafil membranes. Features: Samacomers — Outside simplify the flashing procedures for various penetrations, reducing the risk of leakage at outside comer details. They are available in one size which will accommodate most outside comers. Samacomers - Outside are heat -welded in place, becoming an integral part of the flashing assembly. Packaging: Installation: Availability: Warranty: Each carton contains 20 outside comers. Each box weighs a total of 30 lbs (13.6 kg). After the curb or wall flashings are installed, Samacomers - Outside -are heat welded in place with a hand-held hot-air welder and roller. No caulking or sealants are necessary. Sarnacomers - Outside are available directly from Sika Samafil Authorized Applicators when used within a Sika Samafil Roofing or Waterproofing System. As a Sika Samafil supplied accessory, Samacomers - Outside are included in Sika Samafil's Standard or System Warranty. RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Sarnafil® Maintenance: Technical: Samacomers - Outside require no maintenance. Periodic maintenance of a Sika Samafil system ensures extended performance and reduces life cyde costs. Consistent with industry practices, Sika Samafil recommends inspecting the roof system for damage, plugged drains, weathered seal- ants, etc. at least twice a year and after each storm. Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Sika Samafil provides technical support, Technical staff is available to advise applicators as to the proper installation method. RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Canada Office Sika Samafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1 J5 Tel.: (781) 828-5400 1-800-451-2504 Tel.: (905) 670-2222 Fax: (781) 828-5365 1-800-268-0479 Fax:905) 670- Web: usa.samafil.sika.com Email: webmaster.samafil@us.sika.com Web:`caan s ka.com8 Disclaimer: The information, and. in particular the recommendation relating to the application and end-use of Sike Somali! products,. are given to good faith based on Sika Samafil s current knowledge and experience of the products when properly stored. handled and applied under normal conditions in accordance with Sate Samafil tecornmendahons. In practice. the differences in malenals, substrates and actual site corrritions are such that no war- ranty anranty in respect of merchantability of flMese fora particular purpose, nor any liability arising out of eny legal relationship whatsoever, may be inferred from this Information The user of the product must determine the pmducfs suitability for the Intended application and purpose Sika Samafil reserves the fight to change the properties of its products. The propnetary rights of third parties must be observed. All orders aro accepted concerned. copies of which will be supplied on request subject to our currant terms of sale and delivery Users must always refer to the most recent issue of the local Product Data Sheet for the product Product Data Sheet Edition: 4/2009 Version no.: 0006 Sikaplan Disc Overview: The Sikaplan Disc is a ryt. inch (60 mm) round steel plate used with the Samafastener-XP to attach the 120 inches (3 meters) wide roof membrane to steel and wood roof decks within the seam attached system. Composition: The Sikaplan Disc is a 2% inch (60 mm) round steel plate made from 20 gauge (0.9 mm) minimum AZ -50 Galvalume coated steel that meets the Factory Mutual 4470 criteria for corrosion resistance. Features: The Sikaplan Disc has two concentric rings of 4 patent pending eyehooks. The 8 eyehooks grip the membrane without initiating tears, and are easier to handle than barbs. Raised ribs and an extruded center hole provide increased strength. Packaging: The Sikaplan Disc is packaged in buckets of 1000 pieces each. Each bucket weighs approximately 52 lbs (23.5 kg). Installation: The Sikaplan Disc is positioned on the surface of the membrane and a Samafastener-XP is placed through the center of it. The Sarnafastener-XP is then set into the roof deck, clamping the Sikaplan membrane in place. Availability: The Sikaplan Disc is available directly from Sika Samafil Authorized Appli- cators when used within a Sikaplan roof system. Contact your Sika Samafil Regional Office or visit our website for further information. Warranty: As a Sika Samafil-suppfied accessory; the Sikaplan Disc is included in Sika Samafil's Standard or System Warranty to the Building Owner. RECEIVED CITU OF TUKWILA SEP 3 0 2093 PERMIT CENTER Samafil® Maintenance: The Sikaplan Disc requires no maintenance. Technical: Sika Samafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method of the Sikaplan Disc. RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton. MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: www.sikacorp.com Email: Canada Office Sika Samafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 webmaster.samafil@us.sika.com Web: www.sika.ca Oleeletmer. The information. and. in particular. the recommendation relating lo the application and end-use of Sipa Samatii products, are given In good faith based on Sika Samafil s current knowledge and expenance of the products when property stored, handled and applied under normal conchaons in accordance with Srka Samaiii recommendations. In practice. the d)Herences in materials, substrates and actual site conditions are such that no war- ranty In respect of merehentelnlfty of fitness fora particular purpose, nor any liability arising cul of any legal relationship whatsoever, may be Inferred from this Information The user of the product must determine the product's suitabi1ty for the Intended epplrcabon and purpose Sika Samafil reserves the right la change the pmperbes of its products The proprietary rights of third partes must be observed AN orders am accepted subject to our mutant terms of sale and delivery Users must always refer to the most recent issue o1 the local Product Data Sheet for the product concerned, copies of which will be supplied on request Product Data Sheet Edition: 11/2011 Version no.: 0001 Sikaplan® _45 2(60 _Feltback Composition: Sikaplan® is a white, nominal thickness PVC membrane with a polyester scrim reinforcement. Sikaplan with a feltback is manufacturered with a recycled felt backing. Features: Sikaplan meets the cool roofing requirements of California's Title 24, US- GBC's LEED® program and Green Globes. Codes and Approvals: Sika Samafil's Mechanically Attached Systems using Sikaplan PVC membranes are dassified by Underwriters Laboratories, Inc., Underwrit- ers Laboratories of Canada, FM Global, Miami -Dade and Florida Building Code. Sika Samafil membranes also meet the material requirements of International building code. Packaging: Sikaplan 45 comes in 10 feet x 150 feet rolls weighing approx. 430 lbs and 5 feet x 150 feet rolls weighing approx. 215 lbs. Sikaplan 60 comes in 10 feet x 100 feet rolls weighing approx. 360 lbs and 5 feet x 100 feet rolls weighing approx. 180 lbs. Sikaplan membrane is wrapped in a dear protec- tive film and strapped B rolls to a wooden pallet Installation: Sikaplan is installed by a Sika Samafil Authorized Applicator. Sikaplan shall be installed to an acceptable substrate with Fasteners and plates in the seam overlap in the "Sikaplan Mechanically -Attached System°. All seams will be hot-air welded For watertight protection. Sikaplan can be used on flashings on Sikaplan roof assemblies. Availability: Sikaplan is available directly from a Sika Samafil Authorized Applicator or by contacting your Sika Samafil regional office. For office locations please contact Sika Sarnafil. Warranty: Upon successful completion of the installed roof by the Sika Samafil Autho- rized Applicator, Sika Samafil will provide a warranty to the building owner via the applicator. Maintenance: Sikaplan requires no maintenance. As a prudent preventative measure, Sika Samafil recommends that the building owner or owner's representative inspect the installed roof system For damage, plugged drains, weathered sealants, etc. at least twice a year and after each storm. RECEIVED OOTX OF TUKWILA SEP 302013 PERMIT CENT_LR Sarnafil® Technical Support: Sika Samafd provides technical support. Please contact your local technical representative or technical manager d you need assistance Technical Data (es manufactured): P Reinforcing Malenal Overall Thickness, mil Thickness Above Scrim, and Fell Weight ozlyd& (fettback membrane only) Breaking Strength (M.D.). min.. ibfim. (KNhn) Elongation a1 Break, min, Machine Direction % Cross Direction % Seam Strength, min., (% of originall- Retention of Properties After Heat Aging Tenable Strength, min.. (% or original) Elongation, min., (% of original) Tearing Strength (C.D.). min„ ibf (N) Low Temperature Bend. -40 •F (-40 •C) Accelerated Weathering Test florescent Light, UV exposure) Cracidng (7x magnification) Discatoration (by observation) Crating (7x magnification) Linear Dunensionel Change (C.D.). % Weight Change Atter Immersion in Water. % Static Puncture Resistance. 33Ibf (15 kg) Dynamic Puncture Resistance, 14.7 ft-lbf (20 J) Recycled Content • Failure occurs tluuugh membrane ruptere not seam failure inIttal Solar 7 Year 1 8ect.nco Reflecunce 0.81 0.62 White Corporate Office Sika Same A D(►is(on of Sika Corporation 100 Dan Road Canton. MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafl.sika.com Email: webmaslersamafilaus.stka.r m ASTM lot 'Ittihad. ASTAil Type III D-4434 Spec. — 13751 — 45 M 60 Polyester Polyester 45Lnorninal) 60(nomina — 16 20 26 — — 9 9 D751 200 (95) 230 303 0751 15 20 20 15 20 20 D751 75 Pass Pass D3045 D751 90 Pass Pass D751 90_ Pass Pass 01004 46 (200) 45 45 D2136 Paas Pas' Pass 0154 5.000 I t 10,000 H re 10,000 Ho Nona None None Negligible Negligible Negligible None None None 01204 0.6% max. 0.31 0.24 7570 t 3.0% max. 2.9 2.5 S602 Pass Paris Pass 05635 Peas Pau Pass e -consumer / 196 Poit Consumer mttlsi Thenar 0.85 3 Year Thermal E01):ilfiC 0.85 Mieml•Dade County Product Control Approved Initial Soler Rtflectaancelnder 101 Disclaims: The tlnmiobpn and nperecrw, ate rewrnn.Mepbnretafaprolae eppeeeobnand mean o! See Sarrraeiteoduaa, are prvonin goodre'do based on Sate Salmi's elnentlinee file end 'weenie* cams prodecti'Wein property alarm, nandied snit voted tower :weal conOlipnsn acternence win Sae Sweatt resonanend achtS hlp'acece. the Memos' nmenfrafs. suenrams end.dgel see 00ted40n0 are such that no warranty in respect of maahentabday ot fitness hu • particular purpose, not any llabilityarleing oaf of arty legalMotion,hl`p Whatsoever, nay be Inferred from tale hdermatiod The user or tee prod,rtm✓st delvnruno d -r prodbds atntahalty kr Ma intended eel anon arts ptuoose Sara S.vnaW:atervice ate right to Mwipe the pwtwrlw•s of A prodpds The proane;.tiy tilts M that! Fames rust be bewMsvd. Alt orders aro aceeptad suo)i:..l 10 all COMM fermi 01 I111.rd dewy 1JsWz mud ;AOAS fo the mostrem., duo of chic local Posted Cala Sheet kW ate product c nod. copes of en:ce we be alppeadd on 1150011 73 CR� Canada Office Sika Samafd A Business Una of Sike Canada 6820 Davand Drive Mississauga. ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.aike.com ElrEaCs 61M for roles paws a recti en tasted Suer. RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Product Data Sheet Edition: 04/2012 Version no.: 0007 Sarnafil G459 Flashing Membrane Overview: Samatit G459 flashing membrane is a heat -weldable roofing membrane for- mulated for direct exposure to the weather and is produced with an integral fiberglass mat reinforcement for dimensional stability. G459 flashing mem- brane is used to flash roof penetrations within Samafil Express, Samafast®. Engineered and Adhered roofing systems. G459 flashing membrane can be adhered directly to asphalt -contaminated surfaces. Composition: G459 flashing membrane is a high quality product containing PVC resin, pigments, stabilizers, ultraviolet absorbers, and a fiberglass carrier sheet Sarnafil G459 Flashing Membrane comes in 1T lengths and is 60 mil (1.5) Thick. The standard color is white. Features: The manufacturing process causes G459 flashing membrane to have no built-in stress at time of production and to have a fully -encapsulated reinforcement with no risk of delamination or water -wicking. G459 flashing membrane is thicker than many competitive products which can improve weldability and service life. G459 flashing membrane is highly dimensional- ly stable making it ideal for adhered flashing applications at walls, termina- tions and penetrations. G459 flashing membrane is resistant to asphalt and many other rooftop contaminates. Either side of G459 flashing membrane can be exposed to weather conditions which allows it to cover rooftop con- taminates or act as a sacrificial layer for contaminates being emitted onto the roof. Sika Samafil recommends testing for compatibility. Contact Sika Samafil's Corporate or Regional Offices. Codes and Approvals: Sika Samafil's Adhered Systems using 6410 PVC membranes are clas- sified by Underwriters Laboratories, Inc., Underwriters Laboratories of Canada, FM Global, Miami -Dade and Florida Building Code. Sika Samafil membranes also meet the material requirements of International building code. Packaging: G459 flashing membrane rolls are provided individually and are sealed for shipping. Individual rolls are 168 lbs for 8.56 ft x 65 ft and 83 lbs for 3.25 x 65 ft. Installation: G459 flashing membrane is installed by Sika Samafil Authorized Applicators on walls curbs and certain other penetrations using Sika Samafii's Samacol adhesives. The seams are then heat welded together by trained operators using Sika Samafil's hot-air welding equipment Availability: G459 flashing membrane is available directly from Sika Samafil Authorized Applicators. Contact your Sika Samafil Regional Office or visit our website for further information. RECEIVED COTV OF TUKWILA SEP 3 0 200 PERMIT CENTER Sarnafil® Warranty: As a Sika Samafil-supplied accessory, G459 flashing membrane is included in Sika Samafil's Standard or System Warranty to the Building Owner. Maintenance: G459 flashing membrane requires no maintenance. Technical: Sika Samafil provides technical support. Technical staff is available to advise Applicators as to the correct installation methods of G459 flashing membrane. Technical Data (as manufactured): Parameters Reinforcing Material Overall Thickness, min., inches (mm) Tensile Strength} min., psi (MPa) Elongation at Break, min. Searn Strength*, min., (% of tensile strength) Retention of Properties After Heat Aging Tensile Strength, min., (% of original) Elongation, min., (% of original) Tearing Resistance, min., Ibf (N) Low Temperature Bend, -40 °F (-40 °C) Accelerated Weathering Test (Florescent Light. UV exposure) Cradling (7x magnification) Discoloration (by observation) Crazing (7x magnification) Linear Dimensional Change Weight Change After Immersion in Water Static Puncture Resistance, 33 Ibf (15 kg) Dynamic Puncture Resistance, 7.3 ft-Ibf (10 J) ASTM Test Method Typical Physical praoertieg Fiberglass 0638 0.060 (1.5) D638 1600 (11.1) D638 270% M.D. 250% C.M.D. D638 80 D3045 0638 0638 01004 D2136 G154 D1204 D570 D5602 D5635 95 90 14 (63.0) Pass Pass None Negligible None 0.02% 2.5% Pass Pass • Failure occurs through membrane rupture not seam failure. Dlsclabrer: All information provided by Sika Corporation CSike7 concerning Sika products, including but not kinked to. eny recommendations and advice relating to the eppkcation and use of Sika products, is given in good faith based on Sike's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Walt instructions In prodree. the cli ferences m materials substrates, storage end handling conditions, actual she cendibons and other factors outside of Sika's control ere such that Sika assumes no liability for the provision of such information, advice. recommendations or instructions related to its products. nor shad any legal relationship be created by or ansa from the provision of such information, advice, recommendations orinsiructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right lo change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at use samafil srke.com or by calkng 000451-2504. Prior to each use of any Sika product the user must always read and follow the warnings andinstnrctions on the products most current Technical Data Sheet, product label and Metenat Safety Data Sheet which are available at use.semafl.sika.com or by contacting ti00-451.2504 Nothing contained In any Sika matenals relieves the user data obligation to read and follow the warnings and Instruction for each Sake product es set forth in the current Tecirvcal Dais Sheet. produd label and Material Solely Data Sheet prior to product use. RECEIVED Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800.451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: CITY OF TUKWILA SEP 3 0 2093 PERMIT CENTER webmaster.samafili@us.sika.com Canada Office Sika Samafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Product Data Sheet Edition: 6/2009 Version no. 0004 Sikaflex®- 1 a Overview: Sikaflex-la is a premium -grade, high-performance, moisture -cured. one - component polyurethane -based, non -sag elastomeric sealant used in cer- tain Sika Samafil roofing or waterproofing system flashing details. Typical applications include wall, curb and drain terminations. It is also used as a sealant at pipe penetrations and under certain metal flashings. Composition: See Material Safety Data Sheet for Composition. Sikaflex-la cures to a light gray color with a smooth texture. VOC Content: 40 g/L Features: Sikaflex-1 a bonds well to Slka Samafil PVC membranes and to common building materials. It is easy to apply and has excellent workability charac- teristics. Sikaflex-1 a is USDA -approved, NSF -approved for potable water contact, jet fuel resistant and has high elasticity curing to a tough, durable, flexible consistency with exceptional cut and tear resistance. It meets Federal Specification TTS -0023C, Type 1I, Class A. It is paintable with water-, oil - and rubber -based paints. Sikaflex-1 a is VOC compliant in Califomia and has excellent weatherability and resistance to degradation by ultraviolet Tight. Packaging: Sikaflex-1 a is padcaged in 10.3 fluid oz (305 ml) disposable cartridges (24 per case). A cartridge covers approximately 15 linear It (4.6 m) based on a 3/8 In (9.5 mm) bead. The actual coverage rate will vary depending on the size of the bead. A case weighs 25 lbs (11.3 kg). The shelf life Is 15 months in an unopened cartridge. Installation: The recommended application temperature for Sikaflex-1a is between 40°F (4°C) and 100°F (38°C). For cold weather applications condition cartridges at approximately 70°F (21°C) and maintain that temperature until just prior to use. Do not apply over damp surfaces as this will affect adhesion and may lead to bubbling within the sealant. Clean all surfaces. Substrate must be sound, dean, dry, frost -free, and free of oil and grease. RECEIVED COTY OF TUKWILA SEP 3 0 2093 PERMIT CENTER Samafil® Installation (cont}: Use with adequate ventilation. Sikaflex-1 a is easy to apply with conven- tional caulking equipment. Avoid air entrapment when applying sealant. Do not tool with detergent or soap solutions. Material becomes tack free in about 3-4 hours. Final cure is achieved in 4- 7 days depending on temperature and humidity. Avoid contact with alcohol and other solvent cleaners during cure. Use open cartridges the same day. Store the material in a dry area be- tween 40°F (4°C) and 95°F (35°C). Availability: Sikaflex-1 a is available directly from Sika Samafil Authorized Applicators when used within a Sika Samafil Roofing or Waterproofing System. Con- tact Sika Sarnafil or visit our website www.sikacorp.com for further informa- tion. Warranty: Sika Samafil will replace defective Sikaflex-la material provided the defect is identified by the Sika Samafil Authorized Applicator and acknowledged by Sika Samafil during the time of original installation and application. Main- tenance of this sealant or of any other sealant after original installation and application is not covered by Sika Samafil's Warranty. Maintenance: Sikafiex-1 a must be maintained. Sika Samafil recommends that the Owner or Owner's designated representative inspect the sealant at least twice a year and after each storm. Technical: Sika Samafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Technical Data: Material and curing conditions @ 73°F (23°C) and 50% R.H. Shelf Life Service Range Curing Rate Tear Strength Shore A Hardness Tensile Properties Elongation at Break Tack -free Time Tack -free to Touch Final Cure ASTM D-624 ASTM D-2240 ASTM D-412 Chemical Resistance (RECEIVED CIITV OF TUKWILA 15 months -40°F (-40°C) to 170°F (77°C) 4 hours 3 hours 4 to 7 days 55 Ib/in (9.6 N/mm) 40±5 @ 21 days Tensile Stress @ 21 days 175 psi (1.21 MPa) 550% Good resistance to water and diluted acids and atkalines Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: www.sikacorp.com Email: SEP 30203 PEIRMIT CENTER Canada Office Sika Samafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 webmaster.samafil@us.sika.com Web: www.sika.ca Disclaimer: The information, and. in particular. the recommendation relating to the application and end-use orSika Samafil products. ere given in'good faith based on Srke Samafrrs current knowledge andexpenence of the products when properly stored, handled and applied under normal conditions m accordance with Sika Samafil recommendations, In practice, the differences in matenais, substrates and actual site conditions am such that no war- ranty in respect of merchantability of fitness for a particular purpose, nor any Iabllltyarising out of any legal relationship whatsoever, may be inferred from this information The user of the product must determine the product's suitability for the intended application and purpose Silo Samafil reserves the right to change the properties of Its products. The proprietary rights of third partes must be observed All orders are accepted subject to our currant terms of sale and delivery. risers must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which kW be supplied on request — Product Data Sheet Edition: 05/2013 Version no.: 0001 Sarnatred - V Overview: Samatred-V is a rolled -out, heat welded walkway that has an improved 'chevron" design. Sarnatred-V is used to protect the Sika Sarnafil mem- brane from foot traffic. Composition: Samatred-V is a 96mil (2.4mm) thick, polyester reinforced, membrane made from the same proven formulation as our Sarnafil membrane. Dimen- sions are approximately 39 inches (1.0 m) wide by 50 feet (15 m) long. Features: Samatred-V is dimensionally stable and durable. Sarnalred-V is Tight gray and has a textured surface similar to a chevron pattern. Packaging: Samatred-V is provided in rolls on wood pallets. Installation Roofing membrane to receive Samatred-V shall be dean and dry. Chalk (adhered): lines on deck sheet to indicate location of walkway. Apply a continuous coal of Samacol 2170 adhesive to the deck sheet and the back of Sarnatred-V in accordance with Sika Samafil's installation requirements for this adhe- sive. Make sure to leave the area on the dedk sheet and on the back of the Sarnatred-V thal will be hot-air welded free of adhesive. The entire perimeter of Sarantred-V will be welded. Roll Sarnatred-V into Sarnacol 2170 adhesive then press into place with a minimum 100lb linoleum roller. Clean the deck membrane and the back of Samatred-V in areas to be welded if need be. Hot-air weld the entire perimeter of Samatred-V to the Sika Samafil deck sheet. Check all welds with a rounded screwdriver. Reweld any inconsistencies. For complete instructions on how to install Sika Samafil walkways, refer to Sika Samafil's Applicator Handbook. Important: Check all existing deck membrane seams that are to be cov- ered by Samatred-V with rounded screwdriver and reweld any inconsis- tencies before walkway installation. Do not use solvent -based adhesive when polystyrene is used as an insulation board in the roof assembly or in geographic areas where voc compliance is not met. RECEIVED CITY OF TUKWILA SEP 3 0 209 PERMIT CENTER Samafil® Availability: Samatred-V is available directly from Sika Samafil Authorized Applicators. Contact your Sika Samafil Regional Office or visit our website for further information. Maintenance: Samatred-V may require periodic cleaning or removal of leaves and similar debris. Technical: Sika Samafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method of SamaTred. Technical Data (as manufactured): Parameter Reinforcing Material Overall Thickness, nominal. inches (mm) Tensile Strength, min., psi Elongation at Break, min. Tearing Resistance, min., Ibf Low Temperature Bend, -30° F (-40° C) Fire Resistance UV Resistance Puncture Resistance (Federal Test) Recycled Content UL 410 'Slip Resistance of Floor Surface Material" ASTM Test Method D751 D751 D751 D751 D2136 E108 D2565 2065 Typical Physical Properties Polyester 0.096 (2.4mm) 275 15% 50 Pass 25 Ft. 5,000 hrs. 54 lbs. 1% Post Consumer / 9% Pre Consumer Pass RECEIVED CITY OF TUKWILA SEP 302013 PERMIT CENTER Corporate Office Sika Samafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.samafil.sika.com Email: webmaster.samafil@us.sika.com Canada Office Sika Samafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1L5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: Al! infomnabon provided by Sika Corporacion ('Sika) concerning Sike products. includ+ng but not limited to. any recommendations and advice relating to the application and use of Slka products, is given in good faith based on Sika's cunent experience and knowledge sins prod&&!s when properly stoatd, handled end applied under normal conditions in aCoorderttae with Slice's fnstructrans In practice, the cilia/antes in matenals. substrates. storage and handling conditions, actual site conditions end other factors onside of Sika's control are such that Sika assumes no tiabrlity for the provision of such information. advice, recommendations or instructions related tads products, nor shad any legal relationship be created by or anse from the provision of such Infomnation, advice, recommendations or instructions related to its products. The user of the Sika producf(s) must test the product(s) for sultabtity for the intended application and purpose before proceeding with the full application of the product(s) Sika reserves the right to change the properties of its products without notice All sales of Sika product(s) ere subject to its current terms and conditions of sale which are available at usa samatil sike.com or by calling 800-451-2504. Friar to each use of eny Sika product, the user must always read and follow the warnings and Instruction on the product's most current Technical Date Sheet. product label end Material Safety Data Sheet which are avadable at usa same! sike.com or by contacting 800-451-2504 Nothing contained m any Sika metenels relieves the user of the obligation to read end follow the warnings and instnrchon for each Silo product es set forth rn the Conant Technical Date Sheet, product label and Material Safely Data Sheet prior to product use. I1aE Hatch Railing System Installation Instructions for all Models (RL -S, RL -E, RL -F, RL -NB, RL -L, RL•SS, RL -D, RL -SV) Tools Required for Installation: • Power drill with 3/8 drill bit and 5/16' nut driver bit • (2) 1/2" Wrenches or sockets • (2) 9/16° Wrenches or sockets • 7/16' Wrench or socket - Pliers • (2) Locking pliers • Tape measure • Utility knife • Safety Glasses • Work Gloves Parts Lists • (2-3) Rail Panels (Depending on Model) Number of rail panels supplied is dependant upon roof hatch length. (2) rail panels are supplied for hatches under 5'0 In length and (3) for hatches greater than 5-0' in length. • (1) Gate Panel • (4) Comer Brackets • (8-14) Pivot Brackets (Depending on Model) Number of pivot brackets supplied Is dependant upon roof hatch length. (8) brackets are supplied for hatches under 4'-6' In length, (10) for hatches 4'-6' to 5,-0" In length, and (14) for hatches over 5'-0" in length. • (0-1) Center Brackets (Depending on Model) Supplied only with models designed for roof hatches greater than 5'-0" In length, see Figure 6 on reverse side. • (0-1) Gate mounting post (Depending on Model) Supplied only with models designed for roof hatches 4'-6' and longer in length • (1) Hardware Package (contents listed at tight) • (1) Gate Latch Kit with Instruction Sheet STEP 1: Attaching Corner Brackets For each of the (4) comers of the hatch, drill the mounting holes by damping a comer bracket with loddng pliers on the face of the capflashing with the pivot sleeve projecting "upward as shown in Figure 1. (CAUTION: Do not penetrate the roofing material or inner wall of the curb when drilling). Fasten each comer bracket to the capflashing using 5/16-18 x 3/4' HHCS, 5/16 washers and 5/16-18 locknuts. * Note: Hatches greater than 5'0" in length require a center bracket (see Figure 6 on reverse side). Center brackets should be mounted with pivot sleeves projecting downward. . - STEP 2: Attaching Pivot Brackets Attach (2) pivot brackets to each comer bracket sleeve using '3/8-16 x 4-3/4' HHCS, 3/8 washers and 3/8-16 hex lock nuts as shown in Figure 2A. Hand -tighten so that pivot brackets are allowed to rotate. " Note: For hatches 4'-6' and over in length, use (4) pivot brackets and attach using 3/8-16 x 5-3/4' HHCS as shown in Figure 28 at the locations indicated in Figure 6 on reverse side. RECEIVED CITY OF TUKWILA SEP 3 0 2013 Hardware Package Contents • (4) 3/8-16 x 4-3/4" hex head bolts • (4) 3/8-16 hex locknuts • (8) 3/8 flat washer • (2) Gate hinge pins • (16) 5/16-18 x 3/4" hex head bolts (20) for hatches greater than 5'-0" in length • (16) 5/16-18 hex lock nuts (20) for hatches greater than 5' in length • (32) 6/16" flat washer (40) for hatches greater than 5' in length • (20)110 x 1" drive screws (24) for 2'-0" x 4'-6" hatches, (32) for hatches greater than 5 in length • (1)3/8-18 x 6" hex bead bolt Required for 4'-0" long hatches only. (2) required on hatches greater than 5' in length] • (2) Cotter pins • (6) Nylon washers • (2) Neoprene Pads • (1) Torsion rod Figure 1 Comer , Bracket" Plvot Sleeve Note: Use (2) washers with each bolt. one on face of bracket as shown and one behind the capflashing 0 HATCHES OVER 4'•6" IN LENGTH ONLY (41 Pivot �irari:F.ls Pivot Bracket nnection ' STEP 3: Installing Rail Panels Slide rail panels into pivot brackets. Using power drill and 5/16° nut driver bit, secure posts using #10 x 1' self -drilling drive screws on both sides of post as shown in Figure 3. (IMPORTANT: Top rail must be 42" above the roof level to meet OSHA requirements. To simplify installation, measure and cut 2x4 block spacers and position them under the pivot brackets until rail panels are secured.). Once all rail panels are in place, securely tighten all pivot bracket connections by wrench. Note: one of the rail panels (or gate post) is supplied with the gate hinge brackets attached. Locate rail panel or post with hinge brackets as shown in Figure 6 at bottom of page. STEP 4: Attaching Gate Attach gate by aligning hinge brackets with gate hinge brackets on top and secure with hinge pins, nylon washers, and cotter pins as shown in Figure 4. Adjust hinges to align gate with rail and install #10 x 1° drive screws. (Note: Gate is hinged on the left side as shown in Figure 6. To hinge the gate on the right side, remove the hinge assembles from the gate and side piece. Reverse top and bottom hinges and remount to the gate and side piece. The loop end of the torsion rod will now be at the bottom hinge connection). STEP 5: Installing Torsion Rod Insert bent end of torsion rod into the hole in the bottom hinge bracket as shown In Figure SA. Insert hooked end in center notch of upper hinge bracket by pressing rod into recess as shown in Figure 68 (use pliers If necessary). Gate tension may be adjusted by repositioning rod into other notches in the bracket. Apply neoprene pads to gate where gate contacts post as shown in Figure SC. STEP 6: Installing Gate Latch Install gate latch per the instructions supplied in the gate latch kit. Hinge Pin Nylon Washer NOVI Washer ::•4101i Washer Fi°ure5A Torsion Rod 'Gate Bottom Hinge Connection sof? Hing.IC! nnee tinn Locations Re • uiring (4) Pivot Brackets are circ e to Mounting Post Gate unting Post hQr Model L -NB on 2.-03"- '-6' Roof Hatch hd Center Bracket Model L -L or RL -SS on Roof etch greater than rglidEr-__Thi Th. e Bilco ompany, -.0. Box 1203, New Haven, CT. 05505 U.S.A. Phone: (800)366-6530, Fax: (203)933-8478, E-mail: commercial@biico.com, www.biico.com INSH-020 REV 7.0 RIVE, CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofina.com CERTIFICATIONS 3,, RECEIVED CITY OF TUKWILA SEP "3 0 2013 PERMIT CENTER TGFU.R8992 - Roofing Systems Page 5 of 25 g. "Samatherm 1'or'Sarnatherrn IP h. Atlas Roofing 'ACFoam II' 1. "Samatherm a' j. "5amatherm PerIlte Composite", 'Tapered Samatherm Perilte Composite',-Samathenn Woodfiber Composite", "Tapered Samatherm Woodfiber Composite" or'Samatherm Hai!board" k. 'Samatherm m" 1. 'Samatherm r Membrane:—'G410', 'G410/FeIr, "G410-14', 'G410.14/Felt•, 'G410.15", 'G410.15/Felt', 'G410-18', '0410-18/Fdr, *G410-20", "6410.20/Felt" or •G410-24' (PVC), fully adhered with "Sarnacol 2170" or "Sarnacol 2170 VC adhesive at 1.5 to 2.5 gal/sq, "Samacol 2121' adhesive at 1.75 gal/sq or ''532P, '5327/Felt', "S327-14', ''S327-14/Fele, "S327-15', '5327-15/Felt', '5327-18', "5327-20" or "S327.24" (PVC),'Slkaplan 45,' •51kaplan 60," "Slkaplan 80,' "Slkaplan 45 Feitoadk," "Sikaplan 80 Feltback," or •Slkaplan 60 Fettback,' mechanically fastened. 8. Deck: C-15/32 Incline: 1-1/2 Existing Roof System: — Insulated or noninsulated cap sheet, Class A, 8 or C system to retain the existing Classification Is covered with: Insulation (Optional): — One of the following, any thickness: Celotex - 'Top air, 'Hy -Tee, 'Hy -Tec IP or 'Hy -Therm AP. Membrane:—'G410', '0410/Felt, '6410-14", "G410-14/Felt", "G410-15', '6410-18', 'G410.18/Felt', "G410-20", '0410-20/Felt', '6410.24', '5327', -5327/Felt, '5327.14', 'S327-14/Felt", "S32/-15", "S327-18", "S327-18/Felt, '5327-20', -S327-20/Felt", "S327-24' (PVC) . 9. Deck: C-15/32 Incline: 1-1/2 Existing Roof System: — Insulated or nonlnsulated cap sheet, Class A, B or C System to retain the existing Classification Is covered with: Insulation (Optional): — One of the following, any thickness: Celotex 'Top RIP, "Hy -Tee, "Hy -Tec II' or 'Hy -Therm AP•. Membrane:—'G410•, •G410/Felt', -6410-14', "G410-14/Felt", •G410.15•, "6410.15/Fele,-G410-18', "G410-18/Fele, •0410-20*, •G410-20/FHP or "G410.24" (PVC), fully adhered with "Sarnacol 2170' or "Samacol 2170 VC' adhesive at 1.5 to 2.5 gaVsq or •Samacol 2121" 25 adhes&p �t-t, gal/sq., "S327" mechanically fastened. I f C li E I V E D 10. Deck: Incline: CITY OF TUKWILA k Existing Roof System: — Class A gravel surfaced B -U -R (gravel to remain Intact). SEP 3 0 2013 Insulation: — One of the following, any thickness: Celotex "Top RIP, 'Hy -Tee, 'Hy -Tec LI' or "Hy -Therm AP. PERMIT CENTER Membrane: — 'G410', '6410/Fele, •0410-14', •G410.14/Felt", •G410-15', "G410-15/Felt, 'G410-18", •G410.18/Felt', 'G410-20•, -G410- 20/Felt", 'G410-24' (PVC), fully adhered with "Sarnacol 2170' or "Sarnacol 2170 VC adhesive at 1.5 to 2.5 gal/sq or -Sarnacol 2121' adhesive at 1.71 gal/sq., •5327' mechanically fastened. 11. Deck: C-15/32 Incline: 1-1/2 Existing Roof System: — insulated or noninsulated cap sheet, Class A, B or C system to n:taln the existing Classification Is covered with: Insulation (Optional): — One of the following, any thickness: "5arnatherm-, "Tapered Samatherm", •Samatherm Penile Composite', 'Tapered Sematherm Perlrte Composite', "Samathemt Woodfiber Composite", "Tapered Sernetherm Woodfiber Composite" or 'Samatherm Nallbaard", Membrane: — "G410", "G410/Felt, 'G410-14', "G410.14/Felr, "G410-15", "G410-18', •G410-18/Felt, -G410-20", "G410-20/Felt", •G410-24•, '5327',' 5327/Felt, "S327-14", "S327-14/Felt, "S327-15", "S327-18", "S327-18/FeIt','S327-20', "5327-20/Felt", "S327.24" (PVC). 12. Dock: C-15/32 Indlne: 1-1/2 Existing Roof System: — Insulated or nonlnsulated cap sheet, Class A, B or C System to retain the existing Classification Is covered with: Insulation (Optional): — One of the following, any thickness: "Samatherm", 'Tapered Samatherm`, •Sematherm Perilte Composite', "Tapered Samatherm Perllte Composite, "Samatherm Woodfiber Composite", "Tapered Samatherm Woodfiber Composite- or 'Samatherm Nailboard". Membrane: — "G410', "G410/Felt", '6410-14', "G410-14/Felt", "G410-15', "G410-15/Felt", '6410.18', 'G410-18/Felt",-G410-20', 'G410.20/Fen' or %410-24* (PVC), fully adhered with "Sarnacol 2170' or "Sarnacol 2170 VC adhesive at 1.5 10 2.5 gal/so, 'Sarnacol V949' at 1.5 to 2.5 gaVsq or "Sarnacol 212r adhesive at 1.75 gaVsq.,'5327; mechanically fastened. 12a. Deck: C-15/32 /// Existing Roof System: — I,r.,katen o" * I (I ' gyebeete Class A. B or C System to retain the existing Classification is covered with: / Insulation (Optional): — One of the following. a , ,'.: • • "Samath r ", •Ta pered Sa Membrane: — "SllkeplwT'45, •S kaplan 60,' SI Incline: 1/2 http://database.ul.com/cgi- n/XYV/template/LISEXT/1 FRAME/showpage.html?name=TG... 4/5/2013 Sika Sarnafii World Class Roofing and Waterproofing September 17, 2013 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 Re: Approved Applicator Project: Andover Distribution Center Bldg A Tukwila, WA To Whom It May Concern: This letter is to certify that Wayne's Roofing, Inc. has been an approved and qualified Sika Samafil roofing applicator in good standing since 1991 and qualifies for available Sika Sarnafil roofing warranties. Wayne's Roofing, Inc. has earned the status of Elite Applicator, our highest overall rating relative to quality installations, technical expertise, payment history and integrity. If you have any questions, please contact our office. Regards, Sika Sarnafil Jesse Quezada Western Area Director Sika Samafli, A Division of Sika Corporation • 10701 Holder Street, Cypress, CA 00630 Tel. 800421.1662 • Fax: 714-821.9356 • wwwsiacorp.Wrn RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Sarnafil® Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www,waynesroofina.com WAYNE'S ROOFHG, INC. WARRANTIES 4 RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Sika Sarnafil ward Crass Roofing and Waterpooing 10Year S Warranty Serial No.: SAMPLE SIKAPLAN ROOFING WARRANTY FO Building Owner SAMPLE Building Name: SAMPLE Building Address: SAMPLE Date of Substantial Completion: SAMPLE Date of Inspection: SAMPLE Contractor SAMPLE Sika Sarnafil (`Sika samatil"), warrents to - limitations stated herein, Sike Samafil will repair > a Roofing Accessories installed according to Sika 10 (ten) years commencing with the dale of substantial ste OMMERCI owner of the glnabrng Techni in Don of TERMS, CONDITIONS, LIMITATIO 1. Owner shalt notify Sika Sarnafil on i in writing within one week 2. Hon Sika Samatii'e inspection, Insulation or Accessory Applicator's workmanship Sika Sarnafil's liability shall Samafirs cumulative liability Ihro System. 3. This warranty does not e (a) The Roofing Membra -. - ed by windstorm in excess (b) The Roofing Memb falling objects, civil . _ lance, (c) A deficient pre-existing •, • 'ti (d) There are any alterations • - structures ere pieced 011 or (e) Failure by the or his lessee warranty, mdu • , sealants a • -. (I) A significant = = the build • originally ins (g) Loss of into. aiding, wind (h) Shedd building be the vapor barrier a :. • - (i) The Owner fails to comply �►s 4 During the period of this warranty. Si 5. Should the •- fing Membrane be concise 6. n mer this 7 enforce 5. 8. N 1 ng geinthe led, or ty of the building e doors or other -. -lope co or coo •ndensation , or. very term or galeg or Accessory is ice, or act of Ilion equipment is irs. or through a . • ed to the - • icor reer. in main inking. • , the first business day i Warranty U)L NG Used as: Warranted: PLE MPLE By: , Telephone. SAMPLE LE sq. described above ('Owner). that su Sikaplan Roofing Membrane, Same s by a Sika Samafil Authorized the instal r- r of the Roofing Membra to the terms, condi neutation or S icamr for discovery of -. • , r in the Roofing Sys Samefi!determinesthattheleakis . bye by Sika Same to piicator for • building defect to thatSikaplan embrane, pt as • In the fclo i fled to Sika Sa I's repair the Rooting .embrane, the duration o warren shall not - •• _= the original i be n • void if any of lhl3 following a natural disaster orr..-.•o.or: dY of negligence,. is water • or and/or rep- removal end Sika Sam: - tic Sika Ser - provisi• Thiswarran extend nor is it costs t process th The Owner and Sika S in any way. directly or indi and Sika Sarnafil, or the = i Sandi Roofing System, shallh ab -= • - : nt, as design lion by the •iiration shall take ovemed by, and con IVEN IN LIEU OF ALL ABILI • R FITNESS • APARTIC N ON THE F su 1 shall have firs failure at any extended solely and exclusive rwissassi. _.. •leorlrensferaMe ander an fit hereby a , arise out ther submitted the America Arbitration Association In in Boston. Massadtu - end enforced ina. WARRANT! PURPOSE, TATED N to ret from les in ut fire u in the Sikaplen Roofing M e in the Sika ph three (3) Insulation cost of s, and Sarnafil period of and confirm Samalherm fit Authorized remedies and Accessory. Sika Sikaplan Rooting ding. but not limited to, earthquake, lightning, hail, ting or misuse including, but not led to. vandalism. or f, or objects such : _ ut not limited to fixtures, equipment, or t a the roc • g Witten autho : On from Sike Samatil, or - • escribed in the • er s Guide provided with this s lessee by Sika notynvted wind blown dueblv a fittoa the Roofing Membrane as rtlal or co plete Toss of roof decking, wall ecis, or. to in .. ed design or due to a reduction in a • - ; on slated herein, , its age - : •, .loyees. shaft have = : = ccess ecost otex•• re• .e Roofing Membra 091rren ny paving o -rbu • : • shall be the• v ra :r • until all invoi - or ma -' • s, installatio any of the le _ or cond,tio • • ted he - • • hall • alt be settled by ar such mediation and/or a parties hereto shall be r. THIS WAR • S MERCHA • owner of the titer ct and repair the nyand aldolma (-- - this Warranty, or tit esign, manufacture, ding mediation at the ti approved in n co roof during regular business hours. purposes of Sika Samafirs investigation s responsibility. , end services have been paid for in full of be construed to be a waiver of such • Sarnafil Roofing System is Installed. It does not nce end in writing by Sika Sarnafil end the Roo tem U • ssary, are paid for by the original owner. on law or otherwise), disputes. or slits that e .: -. • - ereof, or to any contacts between the owner hale, bution, installation, and/or inspection of the Sika before a neutraldiator jointly selected by the parties or, in tine In tine ce of resolution by mediation, all such claims e Construction Industry Arbitration Rules. Any T�� •: ty. and any claims, disputes or suits between the nce with, the laws of the Carnmonwealth of Massachusetts. EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF ARE NO WARRANTIES THAT EXTEND BEYOND THE HER ARE EXCLUSIVE REMEDIES AND SIKA SARNAFIL OR INCIDENTAL DAMAGES INCLUDING THE DESCRI • d EO . ALL NOT = - IBLE OR LIABLE FOR t 0 - P ENCE OF MOLDS, FUNGI, BACTERIA, SPO' - WHA • EVER, INCLUDING BUT NOT LIMITED TO, DAMA ARE SI n 0, DAMAGE TO THE CON • EREOF, THEREOF, 0 GE TO ANY • •. ' OPEOR PERS O REPRESENTATIVE OF SIKA SARNAFIL HAS MTV TO MEDI Issued By: SAMPLE • • ANY REP Authorized Signature: SAMPLE Title: SAMPLE Date: SAMPLE Th THE LIKE OR FURTHER LOSS OF ANY KIND IND ON WHICH THE COMPONENTS OF THE ROOF OF THE BUILDING OR ANY COMPONENT PART SENTATIONS OR PROMISES EXCEPT AS STATED HEREIN. Warranty Is effective from: SAMPLE Through: SAMPLE Sika Sarnafil, A Division of Sika Corporation, 100 Dan Road, Canton, MA 02021 Tel.: 1.800-451-2502. Fax: 828-5365 RECEIVED CITY OF TUKWILA SEP 3 0 2013 PERMIT CENTER Sarnafi/'R' ■ __ —. ■ • Roo Whereas WAYNE'S herein called "the Contractor," h Owner: Address of Owner: Type and Name of Building: Location Area of Roof Date of Completion: Date Guarantee Expires: Whereas, at the incept materials or workmanship for a limiter Now, Therefore, period of Five_( _SJ years from made such repairs to said roof and c applied by or through the Contractor This guarantee is made subject to the f I. Specifically excluded from this g omissions of other trades foundation settlement - or roof is applied, fault cons• cti building; vapor Gond- ation of the foregoing this ; aran sl damage is repaired b the Con c 2. The ctor is no liable fo a 3. • 8. In positi o work s races, raili roof, unless recommend this flashin all be d g, pla e Co ons re en tons is ! : tee s s ch u e was origi vered by this This : tee s accordan. with This guaran ee sh workmanshi an This guarant- a is Additional di fitness Wh -••f, •J tf rms tract th eerep be ally ll •. rear rshal • ct 11 an 0 nul cif or t nt me null provided an opt n lieu of all olio ons or exclusio is instrument e 11 n :ing guarantee ROOFING, INCORPORATED, of Sumner, Washington, Ls completed application of the following roof SAMPLE WARRANTY pu has OX X / n of I period he Contractor re date vmpos rs tn. ollo u: trac on o math . hall . xor a m -•e oof, equi be f reto, voi Bio - and and • d rtu n': • -• such and of on be ' gco ee is rs; ligh ng of p:.'.• e • ere the ,! nclu m .t n• and . by oid e •• e t to oid ity t • n du work the C. racto subject . the conditions heresy Guarantees, • ^lettofsaia • shl : resulting nen sa to main.ain • do •: an an all damage , • : wi dstorm, th- • . f : defers - yaE. :pings, .f;.27 tra . ns for i.. 7".. • null • ' : of . party d. • • : • • • • the ng, • t out • -1 ed ,. • se. ted,'•ha' • given •• • enda:ion, Con ,. • or dhalt , work o • ers e roo' is used ificati no e . ive '. and h su • •• • f wes un ess e 1 on • ' pe the • . f. es .r ., :, ties, y - cured this rocf, solely chimneys, p and rogues bui lim on on laid as t. ed in urt� a ctor express day ^ agreed he su it w said r :o sail hailstorm, or failure tch boxes; void ding or Cation the roof, he opportunity are complied be raid roof. promenade parggraph plied. is promptly or of , to • 'n 'ect 11, a om of ' .. sky for . : such contents work and Contractor implied 200X gua • set •' al o the conditions its o n ault , or war: fight f, th- building or • of dial ghts, . fire. 1 e balano repairs. res in connection no repairs to rrake with. for time or work 8 below. has notified ee thr : eon and defecas condition. or unusual; used ✓ents, "the • of the fitting or F nue and deck Areas been of the aforesaid herein set expense, in materiels contents ph as , • . •ports, • f is dan-agtd guarantee from any wi ues, al 'ons necessary to observe material or is sprayed that pond paid in alleged :sake aused ena f t or de shalt expended full defect roof aga forth, o- or by of the ase over other by re peri " in vents. be roofing this condition or flooded, water for in t faulty hal during cause wor ns the acts elemen which parts the of any less such said roof drains, sign made to said application shall in making unless shall not said roof materials a ,e hip or s; le or be in or RECEIVED TY OF TUKWILA SEP 3 0 2013 PERMIT CENTER WAYNE'S ROOFING, INC. 13105 HOUSTON ROAD SUMrNER, WASHINGTON 98390 TAC. (253) 863-4455 SRA.(206) 575-0078 BY AUTHORIZED REPRESENTATIVE Donald Guthrie, President • • PLAN REVIEIROUTING SLIP ACTIVITY NUMBER: D13-306 PROJECT NAME: BUILDING A SITE ADDRESS: 571 STRANDER BL X Original Plan Submittal Response to Incomplete Letter # DATE: 09-30-13 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Ac �3 Lidding Division Public Works ❑ &Y*4- Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-01-13 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 15Z1 Structural Review Required n No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 10-29-13 Approved Approved with Conditions TS< Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: ' Bldg 0 Fire ❑ Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Peter Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LEtl to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name WAYNE'S ROOFING INC UBI No. 600178144 Phone 2538634455 Status Active Address 13105 Houston Rd License No. WAYNESR205Q5 Suite/Apt. License Type Construction Contractor City Sumner Effective Date 11/25/1980 State WA Expiration Date 5/2/2015 Zip 98390 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company iated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status RAINIEI923QLRAINIER EXCAVATING INC Construction Contractor General Unused 11/13/2008 11/13/2014 Active Business Owner Information Name Role Effective Date Expiration Date GUTHRIE, DONALD D President 01/01/1980 Bond Amount WETHERBEE, KITTY Secretary 01/01/2007 1968027 WETHERBEE, RODNEY ALLEN Vice President. 05/01/2000 WETHERBEE, WAYNE W President 01/01/1980 04/30/2007 MANN, SHARON R Secretary 01/01/1980 04/30/2007 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 9 THE HANOVER INS CO 1968027 04/13/2011 Until Cancelled $12,000.0004/11/2011 04/29/2013 8 INS CO OF THE WEST 1329270 07/22/2001 Until Cancelled 04/13/2011 $12,000.0003/20/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 26 American Guarantee ii Liability GLA399116709 05/01/2013 05/01/2014 $1,000,000.00 04/29/2013 25 Zurich American Ins Co GLA399116708 05/01/2012 05/01/2013 $1,000,000.0004/26/2012 24 AMERICAN ZURICH INS CO GLA399116707 05/01/2010 05/01/2012 $1,000,000.0004/29/2011 23 AMERICAN ZURICH INSURANCE CO CP0399116704 05/01/2008 05/01/2010 $1,000,000.00 04/24/2009 22 AMERICAN ZURICH INS CO CP0399116703 05/01/2007 05/01/2008 $1,000,000.00 04/30/2007 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period httns://fortress.wa. 2ov/lni/bbin/Print.aspx 10/08/2013