Project Name: PROP GALLERIES
DEVELOPMENT PERMIT
Permit Number: D13-312
Issue Date: 11/14/2013
Permit Expires On: 5/13/2014
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Contractor:
Name:
Address:
License No:
Lender:
Name:
Address:
CWWATUKWILA 1 LLC
PO BOX A-3879 , CHICAGO, WA,
60690
DAVID KEHLE
1916 BONAIR DR SW , SEATTLE, WA,
98116
ALEXEEV CONSTRUCTION
PO BOX 731152 , PUYALLUP, WA,
98373
Phone: (206) 433-8997
Phone: (253) 230-4788
ALEXECS934P9 Expiration Date: 10/29/2015
SELF FUNDED - KIDDER MATHEWS
DESCRIPTION OF WORK:
REMOVE PORTION OF EXISTING NON-BEARING DEMISING WALL FOR 9 X 12' OPENING WITH NEW HEADER (TO
COMBINE SPACES 1007 & 1017)
Project Valuation: $3,000.00
Type of Fire Protection: Sprinklers: YES
Fire Alarm: YES
Fees Collected: $250.52
Type of Construction: VB Occupancy per IBC: B
Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA
Sewer District: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012
2012
2012
2012
International Fuel Gas Code:
WA Cities Electrical Code:
WA State Energy Code:
2012
2012
2012
Public Works Activities:
Channelization/Striping: N
Curb Cut/Access/Sidewalk: N
Fire Loop Hydrant: N
Flood Control Zone:
Hauling/Oversize Load: N
Land Altering: Volumes: Cut: 0 Fill: 0
Landscape Irrigation:
Sanitary Side Sewer: Number: 0
Sewer Main Extension:
Storm Drainage:
Street Use:
Water Main Extension:
Water Meter: Yes
Permit Center Authorized Signature: -
Date: I t LI 13
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating cons ction or the performance of work. I am authorized to sign and obtain this
development permit and agree to t' :►c nditio •ched to this permit.
I
!1
.,� Irl
Signature:
Print Name:
Date:
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in
responsible charge and the Building Official.
3: All mechanical work shall be inspected and approved under a'separate permit issued by the City of
Tukwila Permit Center (206/431-3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors
prior to start of any construction. These documents shall be maintained and made available until final
inspection approval is granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the
International Building Code or International Residential Code, International Mechanical Code, Washington
State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector
based on satisfactory completion of this requirement.
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
• •
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the
City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or
other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
9: ***FIRE DEPARTMENT CONDITIONS***
10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable
with the following concerns:
11: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may
require relocating and/or adding sprinkler heads. (IFC 901.4)
12: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department
review and approval of drawings prior to installation or modification. New sprinkler systems and all
modifications to sprinkler systems involving more than 50 heads shall have the written approval of
Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the
Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence
without approved drawings. (City Ordinance No. 2327).
13: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may
require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328)
14: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2328) (IFC 104.2)
15: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City
Ordinances #2327 and #2328)
16: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not
imply approval of such condition or violation.
17: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire
Prevention Bureau at (206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1700 BUILDING FINAL**
1400 FIRE FINAL
0409 FRAMING
CITY OF TU•'ILA
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Building
Project No.
Date Application Accepted:
Date Application Expires:
CONSTRUCTION PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
King Co Assessor's Tax No.: 1092../4i dI T
Suite Number: lerri Floor: 1
New Tenant: ❑ Yes g. No
Site Address: we/71 r%4 Q- &(34tiE'..p
Tenant Name: 611.0P
PROPERTY OWNER
Name% vo,e2 h.tt.,1 �,�1!/l
Address: /�j `r IGPh t , tfo.I �V. 0 4
City: --Maw Ska. Zip bg
CONTACT PERSON — person receiving all project
communication
Name: qv io
Address: mt0l� trt„ ov
city:0101 w I�I�Statev Zipddt! I j,,
�����**'' 11��1u�c �D
Phone: .ae,3311��,dAI Fax:, _ ,l/r,, Lr _ ,53(o/
Email: te ea � �"mi . c hfo
GENERAL CONTRACTOR INFORMATION
Company Name:
ii312
Address:
• City:
State: Zip:
Phone: Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.:
H.1Applications\Forms-Applications On Line12012 Applications\Permit Application Revised - 2-7-12 doc c
Revised: February 2012
bh
ARCHITECT OF RECORD
Company Name: tihVegieAvoitviect
Architect Name: t, Keit
Address: I,CW I t I&M w
City 'NState.6 Zip:/1 �I l 41
44/x
Phone Trk.4.33 * Fax Y�.146 41
Email:41.wite Q.466
ite4v M.ce1
ENGINEER OF RECORD
Company Name: /T WO-- Ul
Engineer Name:/410 *IL
iGg 9r
Address: *',e
City:`�'%� nw State:Ua iZiip:4
Phone;g..Z
Email:
Fax: t4. _otp
LENDER/BOND ISSUED (required for projects $5,000 or
greater per RCW 19.27.095)
Name: 42612.h
Address:
City:
State: Zip:
Page I of 4
Inui14v11x(,ruciviti'iN1•'ORMATIO`-206-431-3670
Valuation of Project (contractor's bid price): $ *CM , Qin
Describe the scope of work (please provide detailed information):
Eefrifig - ri letal. . • . Iltr '� M curt
Iry Nor z. - Garr 4c, 1 p 41(e4; le rl-t
Existing Building Valuation: $ l'vt4lu.iO4
turifi
Will there be new rack storage? ❑ ....Yes
..No If yes, a separate permit and plan submittal will be required.
Provide An Building Areas in Square Footage Below
1°` Floor
Addition to
Existing
Existin : Interior Remodel Structure
2nd Floor
3rd Floor
Type of Type of
Construction per Occupancy per
IBC IBC
Floors thru
Basement
Accessory Structure*
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered Deck
Uncovered Deck
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
\lumber of Parking Stalls Provided: Standard: !PD dI 4k14,gi Compact: P Handicap:
Will there be a change in use? 0 Yes fid No If "yes", explain:
SIRE PROTECTION/HAZARDOUS MATERIALS
W Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify)
Jill there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes a No
1f "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Materia! Safety Data Sheets.
EPTI,c SYSTEM
0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
4pplicationsWorms-Applications On Line\2012 Applicasions'Permit Application Revised - 2-7.12 docs
lied' February 2012
Page 2 of 4
PERMIT APPLICATION NOTES;
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section W5.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW
Signature: ]
�
Print Name: r/i'4IP VOW
ORIZED AGENT:
Mailing Address:l4L'(11 is d tj
Date:
Day Telephonek1' 473 "M44
Le -
City
AApplicatfons\Forms-Applications On I.ine12012 Applicubna' ermit Application Revised - 2.7.12 docx
wised: February2012
State Zip
Page 4 of 4
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
QUANTITY PAID
$153.60
D13-312 Address: 1007 INDUSTRY DR 107
Apn: 2523049071
$153.60
$149.10
R000.322.100.00.00
$149.10
STATE BUILDING SURCHARGE
$4.50
STATE BUILDING SURCHARGE
TOTAL FEES PAID BY RECEIPT: R103
B640.237.114
$4.50
$153.60
Date Paid: Thursday, November 14, 2013
Paid By: ALEXEEV CONSTRUCTION SERVICES
Pay Method: CHECK 8749
Printed: Thursday, November 14, 2013 10:43 AM 1 of 1
CRWSYSTEMS
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.2ov
Parcel No.: 0223300020
Address: 631 STRANDER BL TUKW
Suite No:
Applicant: PROP GALLERIES
RECEIPT
Permit Number: D13-312
Status: PENDING
Applied Date: 10/09/2013
Issue Date:
Receipt No.: R13-02840
Payment Amount: $96.92
Initials: JEM Payment Date: 10/09/2013 11:50 AM
User ID: 1165 Balance: ' $153.60
Payee: DAVID E KEHLE
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 055180
ACCOUNT ITEM LIST:
Description
96.92
Account Code Current Pmts
PLAN CHECK - NONRES
000.345.830 96.92
Total: $96.92
Printed: 10-09-2013
13 —3l2—
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION G
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Proje 9
p G A -q e -J I --__S
Type of Inspection: \Pro
1 t. -
! fA L
Address:Date
o74J/LJSW
1 !
Called:
Special Instructions:
"---
Date Wanted:
/
+
1
�-7
— .
a.
-/� .Vm.
Requester:
Phone No:
Approved per applicable codes. t�J Corrections required prior to approval:
COMMENTS:
PP.rM; t 6,0 tico(eXr
V
Inspec
Date)
2 /.3
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
L r3
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Proj t: / (
1K� L,1 .e. i' ? e_ -J
Type o Inspection:\ /
A,.
Address: i
(4007 -7-;:AO LS
Date Called:
Special Instructions:
l D 7Requestier:
N
fi49' SD-Z��
/
Date Wanted:
ii —1(C ---i
• ,A+
A•_..
Phone No:'
7 53,?30'.4r
Approved per applicable codes. Corrections required prior to approval.
COMMENTS:
Inspec
Date)( 1 C"- (3
REINSPECTION FEE REQUIRED. Ptior to: next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
k
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206-575-4407
Project:
-J
, rrOp —2 A -el
Type of Inspection:
Zrze__ Fiet.,„Q
Address:
Suite #: 10p-1 -TNbc -
Contact Person:
Special Instructions: 1
Phone No.:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
y e5
Sprinklers: ye�
Fire Alarm:
0✓!'
Hrs.:
Hood & Duct:
Monitor:
fri;-e 0-11,A41 -----
0 (Z. -
Permits:
Occupancy Type:
V. --
J-7(.4_ AY p
)8
,_ W as I% -J
--- 01(
Needs Shift Inspec ion:
y e5
Sprinklers: ye�
Fire Alarm:
0✓!'
Hrs.:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector:�L
r.,yv .-3
Date:
1 t lot R
Hrs.:
1. 0
1
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. CaII to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
2009 Washington S nergy Code Compliance Forms for Nonresid- I and Multifamil
Envelope Summary
2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential
Project Info
Project Address
t
e{b1, altEr I
Applicant Name: i 1p viola
Applicant Address: ICI + A' i g 02 !A. . Oa lb. t'I i tP
Applicant Phone: - 4-33 -rd 941 -
Project Description
❑ New Building ❑ Addition
Alteration
Compliance Option
❑ Prescriptive ❑ Component Performance
(See Decision Flowchart (over) for qualifications)
Occupancy Group
4 Nonresidential 0 Multifamily Residential
Climate Zone
4 Climate Zone 1 0 Climate Zone 2 ( See
Fenestration Area Calculation
Total Fenestration Electronic version: these values are automati
(rough opening) . Gross Exterior
(vertical & overhd) divided by Wall Area
l'iik ÷
Semi -Heated Patho
0 yes Allowable if project meets all requirements as defined in section 1310.2
no calculated separately from other conditioned spaces. Limited to reduce
and qualifying thermostat.
Envelope Requirements (enter values as applicable)
Minimum Insulation R -values
Roofs - Insulation Above Deck
Roofs - Metal Building
Roofs - Single Rafter
Roofs - Attic and All Others
Walls - Mass
Walls - Metal Building
Walls - Steel Framed
Walls - Wood Framed and Other
Floors - Mass
Floors - Steel Joist
Floors - Wood Framed and Other
Maximum F -factors
Slabs -on -Grade - Unheated
Slabs -on -Grade - Heated
Notes:
Envelope Requirements
Vertical Fenestration
Non -Metal Frame
Metal Frame
Entrance Door
WSE(
Skylights - Without Curb
Skylights - With Curb
Opaque Doors - Swinging
Opaque Doors - Non-Swir
Vertical Fenestration
Non -North
North
Skylights
ally t
. Only
iwalli
2009 Wasnin•ton State E
Code Compliance Form for Nonresidential - - ultifamily Residential
Interior Lighting Summary.
n ton State Ener Code Compliance Forms for Nonresidential and h7ultifamily Residential
LTG -INT
Revised November 2010
Project Info
Project Address pari9
Date lO1fl \h
—
f'V VAiiV4'Ot( 1er)1 4 Iv i
For Building Department Use
l
Applicant Name: CA 10 EI l ie Njt C1
Applicant Address: Kip NA ✓12' '. N L/iit . va6 lei ( it,
Applicant Phone: ;L0 . L 5 3 . ` fir lq /"
Project Description
❑ New Building ❑ Addition' Alteration ❑ Plans Included
Refer to WSEC Section 1513 for controls and commissioning requirements.
Compliance Option
0 Prescriptive 0 Lighting Power Allowance 0 Systems Analysis
(See Qualification Checklist (over). Indicate Prescriptive & LPA spaces clearly on plans.)
Alteration Exceptions
(check appropriate box - sec. 1132.3)
>.. No changes are being made to the lighting and space use not changed
0 Less than 60% of the fixtures new, installed wattage not increased, & space use not changed.
wed Lighting Wattage
Location
(floor plan/room #)
Occupancy Description
Allowed
Watts per ft2 ""
Gross interior
Area in ft2
Allowed x Area
'" From
Table 15-1 (over) - document all exceptions on form LTG -LPA Total Allowed Watts
Proposed Lighting Wattage
Location
(floor plan/room #)
Fixture Description
Number of
Fixtures
Watts/
Fixture
Watts
Proposed
Total Proposed Watts may not exceed Total Allowed Watts for Interior Total Proposed Watts
Notes:
1. For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if
included). For track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
2. For proposed Watts/Fixture, use manufacturer's listed maximum input wattage of the fixture (not simply the lamp wattage) and
other criteria as specified in Section 1530. For line voltage track lighting, list the greater of actual luminaire wattage or length of track
multiplied by 50, or as applicable. the wattage of current iimiting devices or of the transformer. For low voltage track lighting list the
transformer rated wattage.
3. List all fixtures. For exempt lighting, note section and exception number, and leave Watts/Fixture blank.
aitacte utottuct
'1
4
CT
ENGINEERING
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 01 2413
City of Tukwila
BUILDING DIVISION
INC.
PILE COPY
pp." 4•
-
TRUCTURAL CALCULATIONS
New opening in non-bear/non-shear wall
1007 1hdto,
Tukwila, WA
180 Nickerson St.
Suite 302
Seattle, WA
98109
(206) 285-4512(V)
(206) 285-0618(F)
Architect: David Kehle, Architect
Scope of Work: Install 12' x 12' opening in an existing non-bearing / non -
shear wall.
Code: IBC 2012 Edition
Loads: Partition wall 5 PSF
Structural Engineers
09/25/2013
RECEIVED
CITY OF TUKWILA
OCT 092013
PERMIT CENTER
Project:
i
Date: 9/4 t3
Client: Page Number:
180 Nickerson St.
Sulte 302
Seattle, WA
98109
(206) 285-4512
DAX:
(206)285.0618
Vt: Ite)�..
,
q.
calC2)16
141(Ski
Tz� 240
TZo
oost(o2-33DL
Cccaa'ci.so- 3 . Va.
Tolt4Ld LAPP c ( 4S CO*:E.Lrhticati
I*
1/44
- iz
:ta
1v1^1t5 . SZ:uta (s)
Out o ?u0Nic
12.
�..-_ I°. - 1-21y4
lei
r 2_876i),
Z2qa
1 1
Structural Enalneers
C
ENG I N E E I N G
Project.
1 N 0.
(O3\ S19,1,44,0 D
•
Date: C,'2- /13
Client: Page Number: ."20*--"
180 Nickerson St.
Suite 302
Seattle, WA
98109
(206) 285.4512
FAX:
(206) 285-0618
Structural Engineers
ENGINEERING
•
//� 1 7
1 N 0.
Project: Go 3 5 1 aANtIotit.� .1� O Date: 1/745/6
Client:
Page Number: S lc- t
180 Nickerson St.
Suite 302
Seattle, WA
98109
(206) 28S•4512
IjAX:
(206) 28S•0618
!PERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: D13-312 DATE: 10/09/13
PROJECT NAME: PROP GALLERIES
SITE ADDRESS: I -_f) 01 I1/11AS
X Original Plan Submittal vResponse to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
01)4'02
Building Division IN
lb—t3
Public Works
P v t J(' tO 2'b' 19)
■
Fire Prevention
Structural
tt)/4 to -to -1
1111
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
•
Incomplete
Complete
DUE DATE: 10/10/13
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route Eft
REVIEWER'S INITIALS: DATE:
Structural Review Required ❑
No further Review Required ❑
APPROVALS OR CORRECTIONS:
DUE DATE: 11/07/13
Approved ❑ Approved with Conditions ` Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
I
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
1
PLAN REVIEW CHECKLIST - (Nonstructural) Permit App. dD/Y7/ 2,
By: IBC Edition ! 2 & State Amend.
Date: I -/6 -(1 Project title: Pjiap 6a /(, i- r
+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++
242r- Classify the building or portion thereof in accordance with Chapter 3
'Determine the type of construction of the building in accordance with Chapter 6.
)R-- Determine if the location of building on the site and clearances to property lines and
other buildings on the site plan are in accordance with code provisions.
Xj" Review for conformity with" General building height and area limitations in accordance
with Chapter 5.
Review for conformity with special detailed requirements based on use and
Occupancy.
Review for conformity with Type of Construction requirements of Chapter 6.
Y<L-- Review for conformity with Fire and Smoke protection features of
Chapter 7.
Review for conformity with requirements of interior finishes of Chapter 8.
Review for conformity with requirements for fire protection systems of Chapter 9.
Review for conformity with requirements for means of egress requirements
of Chapter 10
>217 Review for conformity with requirements of accessibility in accordance with Chapter
11, and ICC A117.1
Review for conformity with Washington State Energy Code.
++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++.
✓ In circle = topic has been reviewed for the application.
X In circle = topic is not relevant to proposed scope of work.
Contractors or Tradespeople Prir Friendly Page
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name ALEXEEV CONSTRUCTION SVCS LLC UBI No. 602767386
Phone 2532304788 Status Active
Address Po Box 731152 License No. ALEXECS934P9
Suite/Apt. License Type Construction Contractor
City Puyallup Effective Date 10/29/2007
State WA Expiration Date 10/29/2015
Zip 98373 Suspend Date
County Pierce Specialty 1 General
Business Type Limited Liability Company Specialty 2 Unused
Parent Company
ther Associated Licenses
License
Name
Type
Specialty 1
Specialty
2
Effective
Date
Expiration
Date
Status
ALEXEM'978RW
ALEXEEV
MAINTENANCE
Construction
Contractor
Other
(Specify)
Unused
12/16/2003
12/16/2007
Re
Licensed
Business Owner Information
Name
Role
Effective Date
Expiration Date
ALEXEEV, ALEXANDRA
Manager
10/14/2013
Amount
ALYEKSYEYEV, OLEKSANDR
Partner/Member
10/29/2007
10/14/2013
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
CBIC
SF2145
10/22/2007
Until Cancelled
$12,000.00
10/29/2007
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
7
Ohio Security
Ins Co
BKS53146520
11/16/2013
11/16/2014
$1,000,000.00
10/30/2013
6
American Fire
& Casualty Co
BKA53456758
11/16/2013
11/16/2014
$1,000,000.0010/30/2013
5
American Fire
& Casualty Co
BKA53456758
11/16/2012
11/16/2013
$1,000,000.00
11/02/2012
4
American Fire
Et Casualty Co
BKA53456758
11/16/2011
11/16/2012
$1,000,000.00
10/28/2011
3
AMERICAN FIRE
& CASUALTY
BKA53456758
11/16/2008
11/16/2011
$1,000,000.00
10/22/2010
OH2 co10 CAS INS
BH053456758
11/16/2007
11/16/2009
$1,000,000.00
11/05/2008
1
OOHIO CAS INS
BH053456758
11/16/2006
11/16/2007
$1,000,000.00
10/29/2007
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
httos: //fortress. wa. gov/lni/bbip/Print. aspx
11/14/2013
13UI1 DING 4 SITE STATISTICS
EUILDINC3 CODE:
ZONING:
SEISMIC ZONE:
CONSTRUCTION TYPE:
OCCUPANCY CROUPS:
ALLOUJABLE SUILDINCZ
NO CHANGES TO
NO CHANGES TO
NO CHANGES TO
18C 2012
M -I
ZONE 3
V -B SPRINKLERED
845-1
AREA: UNLIMITED, 60' YARD ON ALL SIDES,
AND FULLY SPRINKLERED.
PARKING
EXTERIOR
BUILDING ENVELOPE
AREA OF TENANT: 11,133 SF COMBINED SPACES
AREA OF REMODEL: 100 SF
TAX ID.
252304 9011
LEGAL
TSV
0 O'
OF PROP. LN.
ID=
SET8ACK
FOUND RR
SPIKE W/ "X"
28/00
15'- UTILITY
EASEMENT
N88'12'32"W
254.00
ROAD STRIPE
THAT PORTION OF THE SOUTHEAST QUARTER OF THE SOUTHEAST QUARTER OF
SECTION 26, AND THE .SOUTHWEST QUARTER OF THE SOUTHWEST QUARTER OF
SECTION 25, ALL IN TOWNSHIP 23 NORTH, RANGE 4 EST, WM IN KING COUNTY,
WASHINGTON, DESCRIBED AS FOLLOW:
BEGINNING AT THE ,QUARTER CORNER COMMON TO SAID SECTION 25 ADN 26 ±
THENCE SOUTH 02022'20" WEST 1319.15 FEET TO THE CENTERLINE OF P-11
ORRAINAGE CHANNEL, WHICH CHANNEL CONTINUES SOUTH 66D12'32 EAST TO
TERMINUS AT THE WESTERLY MARGIN OF CHRISTENSEN ROAD± THENCE $8012'32
EAST TO TERMINUS AT TI -IE WESTERLY MARGIN OF CHRISTENSEN ROAD± THENCE
6SD12'32" WEST ALONG THE S1AD P-11 DRAINAGE CHANNEL CENTERLINE 92.45
FEET± THENCE SOUTH 01041'26" WEST 21.00 FETT TO THE TRUE PONT OF
BEGINNING± THENCE CONTINUING SOUTH 01D41'2S" WEST 453.35 FEET TO A POINT
OF CURVE± THENCE ALONG A CURVE TO THE RIGHT HAVING A RADIUS OF 391.24
FEET AND A CENTRAL ANGLE OF 25010'31" AND ARC DISTANCE OF 114.56 FEET±
THENCE SOUTH 26055'05" WEST 50.00 FEET± THENCE SOUTH &SD12'32" EAST 169.01
FEET± THENCE NORTH 01041'243" EAST 661.59 FEET± THENCE =NORTH 60012'32" WEST
WEST
110.00 FEET TO THE TRUE POINT OF BEGINNING.
SUBJECT TO AND INCLUDING AN EASEMENT FOR UTILITIES OVER THE NORTH 15.00
FEET THEREOF.
SUBJECT TO AND INCLUDING AN EASEMENT FOR RAILROAD PURPOSES OVER THE
UESTERLY 21.00 FEET THEREOF.
19
15' N N EX LUSIVE
DRAINAGE AND- UTILITY;
EASEMENT
AREA OF TENANT
15' WIDE
DRAINAGE
& UTILITY
EASEMENT
BLDG 32
19,254 S.F.
SEPARATE PERMITS:
PLUMBING
HVAC MODIFICATIONS
ELECTRICAL
SPRINKLER MODIFICATIONS
SCOPE OF WORK
REMOVE PORTION OF AN EXISTING NON BEARING DEMISING WALL TO -
COMBINE TWO SPACES TOGETHER, CONSTRUCT IN HEADER FOR OPENING
REVISIONS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 0 7 2013
Ay—
City o Tu ila
BUILDING VISION
54.2
1
I--- 54.2`'
BLDG 30
15,127 S.F.
PARCEL 3
6.3'
3.5'
5' WIDE
SETBAC K
No changes shall be made to the scope.
of work without prior approve! of
Tukwila Building Division
NOTE: Revisions will require a new plan submitt?l
and may include additional pian review fees.
SL
54.0'
BLDG 33
66,911 S.F.
SEPARATE PERMIT
REQUIRED FOR:
Mectlanical
Electrical
Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
3.4'
5.1'
5.3'
FOUNT NAIL
W/WASHER LS#8271
S89'33'15"W 0.16'
8/21/00
BLDG 40
16,087 S.F.
3.0'
FILE COPY
Permit No... 171`
Plan review approval Is sublect to errors and omissions.
Approval of c onstn tion documents does not authorize
the violation of any as ,,o 1 .+ , • , • • Dane. Receipt
of approved Field ,� , wieacked:
‘11. 1I
. rrw
15' WIDE
SETBACK
S88'1 V327E
City °fits la
BUILDING DIVISION
z
0
a.
0
CA
0
CD
rnr
00 00'
re)
N
0 0
00
N N
vu
LtJ
O X
EL la-
0
0
',RECEIVED
CITY OF TUKWILA
OCT 09
PERMIT CENTER
FOUND REBAR &
CAP W/TK LS#
NOT LEGIBLE
N85' 11'28"E 0.10'
8/21/00
b13-312
C:IDocuments and Settings\Ali Users\Documents\CAD1200210225 GVA -KMITukwila Commercelsd-1.dwg, D-1,10/9/201310:14:55 AM ` .
GUT OUT GYP BD TO EXPOSES
STUDS AND PO NEW CONNECTIONS
50X I-1E,4DER, 600 T150-33 T AND
5
2-6005162-33 50X SIDES
ATTACH T AND 5 TO 50X SIDES
WITI-1 *8.912" O.C. SCREWS
NEW GYP BD WRAPPED OPENING
435 W/ *S SCREWS
BOX HEADER AT
OPENING
SCALE: 1. 1/2"
1'/ril
NEW FULL I -1E I41 -4T 'r OUBLE
JAMB STUDS, (000-162 -43
3 SCREWS E CI -I SIDE
A35 W/13 S
AND 2-3-3/1
,ACI-IORS T
REWS TO STUDS
"Xl 1/2" TITEN
SLAB
EXISTING STUDS, CUT OFF FOR
NEW OPENING
NEW MAX. 12' WIDE X _12TALL
OPENING
NEW 50X HEADER (SEE
ABOVE DTL)
COPE FLANGE FOR
4TTACI-IMENT TO STUD
CUT SILL TRACK FQR OFE MING
VERIFY WIDTI-1
NEW OPENING ELEV.
SCALE: 12" = 1'-0"
L ON.
WAREHOUSE
WAREI-IOUSE
POM
SUITE 1007
o
FRIR
OFFICE
COM
OPEN
OFFICE
OFFICE
COM
OFFICE
REMOVE 9'X12' PORTION OF
EXISTING DEMISING WALL, NEW BOX
I-IEADER AND NEW VERTICAL EDGE
STUDS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 0 7 2013
City of Tukwila
BUILDING DIVISION
WAREHOUSE
OFFICE
] Rid
OPEN OFFICE
ADJACENT SUITE 1025
SUITE 1011
b33Iz
RECEIVED
CITY OF TUKWILA
OCT 0 9 2013
PERMIT CENTER
0225 GVA
w
LLI
0
cri
114
0
ifi
0
rn t
co
00 03
1
CO
•;1-N
C.0CO
N N
W
ox
1<
CL
C'\DncumAnts and SOttinnakAll llsarAm.n..mant4\CAntanfl9\f199a r IA_ICLAXTi.4wile:TnmmernelT_1 ,4...i. T_4 4(IflP)I14el 4A.4m9fl Au