Loading...
HomeMy WebLinkAboutPermit D13-317 - TUFF SHED - REROOFTUFF SHED - REROOF 17500 WEST VALLEY HY D13-0317 City oilf ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 2523049033 Address: 17500 WEST VALLEY HY TUKW Suite No: Project Name: TUFF SHED - REROOF DEVELOPMENT PERMIT Permit Number: D13-317 Issue Date: 10/24/2013 Permit Expires On: 04/22/2014 Owner: Name: ALCO INVESTMENT COMPANY Address: PO BOX 3546 , SEATTLE, WA 98124 Contact Person: Name: ERIC PALMER Address: 13105 HOUSTEON RD , SUMNER, WA 98390 Contractor: Name: WAYNE'S ROOFING INC Address: 13105 HOUSTON RD , SUMNER, WA 98390 Contractor License No: WAYNESR205Q5 Lender: Name: ROSEN INVESTMENT COMPANY Address: 27402 72 AV S , KENT, WA 98032 Phone: 253-863-4455 Phone: 253-863-4455 Expiration Date: 05/02/2015 DESCRIPTION OF WORK: RECOVER OF EXISTING BUILT-UP ROOFING WITH 1/2" HD COVERBOARD AND PVC ROOF SYSTEM. SYSTEM TO BE MECHANICALLY ATTACHED THROUGH EXISTING PLYWOOD DECK. Value of Construction: $153,786.00 Fees Collected: $3,255.99 Type of Fire Protection: International Building Code Edition: 2012 Type of Construction: Occupancy per IBC: 0010 Electrical Service Provided by: PUGET SOUND ENERGY **continued on next page** doc: IBC -7/10 D13-317 Printed: 10-24-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: N Number: 0 Size (Inches): 0 Flood Control Zone: Hauling: N Start Time: End Time: Land Altering: Volumes: Cut 0 c.y. Fill 0 c.y. Landscape Irrigation: Moving Oversize Load: Start Time: End Time: Sanitary Side Sewer: Sewer Main Extension: Private: Public: Storm Drainage: Street Use: Profit: N Non -Profit: N Water Main Extension: Private: Public: Water Meter: N. Permit Center Authorized Signature: Date: 10--)J-N(3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel fhe provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. / /� Signature: �� Date: C� �{ 1 3 Print Name: r. L T, Pc.Le. K This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: Manufacturers installation instructions shall be available on the job site at the time of inspection. doc: IBC -7/10 D13-317 Printed: 10-24-2013 7: Prior to final inspection for this building pet, a copy of the roof membrane manufacturevarranty certificate shall be provided to the building inspector. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IBC -7/10 D13-317 Printed: 10-24-2013 i' CITY OF TUKA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building P• ermit No. /0 ( 3- 3 ( 7 Project No. I Date Application Accepted: 1 O- l0-\ 3 Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: Tenant Name: 1-1500 (-Jest adle;1.4,„,t 5LeaQ 1 PROPERTY OWNER Name: Rose n ,rix✓ est t-cn{ Cv ^^es x Address: a. ptoa - '-/ 2,I,S A v -c, Sa*'-- City: Q.._+- State: kiA- Zip: Iio3a CONTACT PERSON - person receiving all project communication n Name: E (�1 c_ `,p1,47 (Ci✓ Kc p4) Address: 1.310 5+1,,,,54,...„. gds, O City: c"n.ec- State: w ,A_ Zip: 1 03 gt. Phone:6S3).3--4. 4 S 5 Fax: 0._s) $C3-931 Email:- .c1!tG�(.,,, _tA.e5_^O Co'a.6- d GENERAL CONTRACTOR INFORMATION Company Name: vj a �L Q 4^C-. 7-- Address: \'31o5 it, ..,5A6 D.. City: 5��W i„1/ State: 4- Zip: c g310 Phone: ) gC3_ciLi S 5 Fax: Os53)63 _ 01\ Contr Reg No.: („/AY/R4-z05 as Exp Date: Tukwila Business License No.: H:\AppIications\Forms-Applications On Line \2012 Applications\Permtt Application Revised - 2-7-12.docx Revised: February 2012 bh King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes a. No ARCHITECT OF RECORD .A1/1A- Name: e c se� a n o e C o eM t_ Company Name: - Architect Name: City: ice.z1/4....-State: LJ A Zip Address: 32 City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Al/ fi. Name: e c se� a n o e C o eM t_ Company Name: Address: a- t00 _ --% i,) Ave S..,�k Engineer Name: City: ice.z1/4....-State: LJ A Zip Address: 32 City: State: Zip: Phone: Fax: Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: e c se� a n o e C o eM t_ Address: a- t00 _ --% i,) Ave S..,�k City: ice.z1/4....-State: LJ A Zip 8 0 32 Page 1 of 4 BUILDING PERMIT INFORMATS— 206-431-3670 • Valuation of Project (contractor's bid price): $ $ 6 Existing Building Valuation: $ Describe the scope fwork (please provide detailed info ation): ) 4 cau-e/ o`C (adN,n-kp Pvc- rco`C S ) d�,� '`f)jS.�o�•► y 5� ati�, ��`�'�, d� d �1 1 13 ' 1 �l 411h t.Uc cX J _. J. J Will there be new rack storage? 0 ....Yes No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? 0 Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Compact: Handicap: No If "yes", explain: 0 Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes X,. No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplrcations\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type: of Occupancy per IBC 1' Floor rd Floor 3rd Floor Floors a so - a o s F ` _____ . ---^ _ ct,dim Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Will there be a change in use? 0 Yes FIRE PROTECTION/HAZARDOUS MATERIALS: Compact: Handicap: No If "yes", explain: 0 Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes X,. No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM ❑ On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:Wpplrcations\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Page 2 of 4 PERMIT APPLICATION NOTES -. • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Ert .. 1 e I r..t/ Mailing Address: l3 5 f L L ,� H:\Applications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Date: 41(0/1-3 Day Telephone: S3) G — 2- ) k S61 rt &a./\ L., A- cta City State Zip Page 4 of 4 PUBLIC WORKS PERMIT IN TION — 206-433-0179 • Scope of Work (please provide detailed information): Call before you Dig: 811 Please refer to Public Works Bulletin #1 for fees and estimate sheet. Water District ❑ .. Tukwila 0 ...Water District #125 ❑ .. Water Availability Provided Sewer District ❑ .. Tukwila ❑ .. Sewer Use Certificate ❑ ...Valley View ❑ ...Sewer Availability Provided ❑... Highline 0... Renton ... Renton Renton ❑... Seattle Septic System: 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. Submitted with Application (mark boxes which apply): ❑ .. Civil Plans (Maximum Paper Size — 22" x 34") ❑ .. Technical Information Report (Storm Drainage) ❑ .. Bond 0... Insurance ❑... Easement(s) Proposed Activities (mark boxes that apply): ❑ .. Right-of-way Use - Nonprofit for less than 72 hours ❑ .. Right-of-way Use - No Disturbance ❑ .. Construction/Excavation/Fill - Right-of-way 0 Non Right-of-way 0 0... Geotechnical Report 0...Maintenance Agreement(s) 0 .. Traffic Impact Analysis ❑ .. Hold Harmless — (SAO) ❑ .. Hold Harmless — (ROW) 0...Right-of-way Use - Profit for less than 72 hours 0...Right-of-way Use — Potential Disturbance ❑ .. Total Cut cubic yards 0... Work in Flood Zone ❑ .. Total Fill cubic yards 0... Storm Drainage ❑ .. Sanitary Side Sewer 0... Abandon Septic Tank ❑ .. Cap or Remove Utilities ❑... Curb Cut ❑ .. Frontage Improvements 0... Pavement Cut ❑ .. Traffic Control 0...Looped Fire Line 0 .. Backflow Prevention Fire Protection Irrigation Domestic Water ❑ .. Permanent Water Meter Size (1) ❑ .. Temporary Water Meter Size (1) ❑ .. Water Only Meter Size " ❑ .. Sewer Main Extension Public 0 ❑ .. Water Main Extension Public ❑ ❑... Grease Interceptor ❑... Channelization 0...Trench Excavation ❑ ... Utility Undergrounding WO # (2) " WO # (3) WO # (2) " WO # (3) WO # 0 .. Deduct Water Meter Size Private 0 Private 0 " WO# " WO# FINANCE INFORMATION Fire Line Size at Property Line Number of Public Fire Hydrant(s) 0 .. Water 0 .. Sewer 0 .. Sewage Treatment Monthly Service Billing to: Name: Day Telephone: Mailing Address: City State Zip Water Meter Refund/Billing: Name: Day Telephone: Mailing Address: City State Zip H:\Applications\Forms-Applications On Line \20I2 Applications\Permit Application Revised - 2-7- 12.docx Revised: February 2012 Page 3 of 4 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.ov Parcel No.: 2523049033 Address: 17500 WEST VALLEY HY TUKW Suite No: Applicant: TUFF SHED RECEIPT Permit Number: D13-317 Status: PENDING Applied Date: 10/10/2013 Issue Date: Receipt No.: R13-02859 Initials: User ID: WER 1655 Payment Amount: $3,255.99 Payment Date: 10/10/2013 02:50 PM Balance: $0.00 Payee: WAYNE'S ROOFING INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 8382 3,255.99 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $3,255.99 1,970.60 1,280.89 4.50 Printed: 10-10-2013 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION L 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206).431-367 Permit Inspection Request Line (20.6) 431-2451 /.3 __3 ProjectType i of t /Z -e.- ye -trot- of Inn: spectio Ro. (O.A.6 VA Address:Date 175.° ° - u ,A— fi t Called: Special Instructions: - Date Wanted:a.m. 3- (6----( p.m. Requester: ,/ Phone. No /� -8'0 . 4 P .. Approved per. applicable codes.. Corrections required prior to approval. COMMENTS: P M,( f)(eire Date: r-/ei -n REINSPECTION FEE REARED. Prior to next inspection, fee must be -paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD ( _ f I Retain a copy with permit 3 3 INSPECTIO NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-367 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 Projec'•u_F���� �p�i��f p"tiq�: _-+�"� Of" -{4 �vf. c -a o ia-,t-r Q Nil AdI rr-7 6p , , r VA- / (� Date Called: Special Instructions: 71------- Date Wanted: / l — C - (3 �`m� p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: -{4 �vf. c -a o ia-,t-r Q Nil •T't. rA-e oF isQr,i.o:AL, r ----,`Ai Att,;---- Inspecto co-13-trr"\-0 Dater . j 1 - 1.3 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Sika Sarnafil -ru s� World Class Roofing and Waterproofing IL aD 20 Year System Warranty 3 _317 Warranty Serial No.: 0000013932-052214.1 SIKA SARNAFIL ROOFING WARRANTY FOR COMMERCIAL BUILDING Building Owner: Building Name: Building Address: Alco Investment Company 17500 West Valley Highway Building 17500 West Valley Highway Tukwila, WA 98188-5500 Applicator: Wayne's Roofing, Inc., 13105 Houston Road, Sumner, WA 98390 Date of Substantial Completion: 2/1/2014 Date of Inspection: 1/29/2014 Building/Area Name: 17500 West Valley Highway,, Used As: INDUSTRIAL BUILDINGS- WAREHOUSES Area Warranted: 52,580 sq. ft. PERMIT��++ ��tt Sika Samafil warrants to the owner of the building described above ("Owner"), that subject to the terms, conditions, and limitans"S�tiairE , Sika 'Samafil will repair Teaks originating from the Samafil Roofing Membrane, Samatherm Insulation or Sika Samafil Roofing Accessories installed according to Sika Samafil's Technical instructions by a Sika Samafil Authorized Roofing Applicator for a period of 20 (twenty) years commencing with the date of substantial completion of the installation of the Roofing Membrane. TERMS, CONDITIONS, LIMITATIONS 1. Owner shall notify Sika Samafil on the first business day immediately following the discovery of each leak in the Roofing System and confirm in writing within one week. 2. If on Sika Samafil's inspection, Sika Samafil determines that the leak is caused by a defect in Samafil's Roofing Membrane, Samatherm Insulation or Accessory provided by Sika Samafil to the Applicator for this building or from a defect in the Sika Samafil Authorized Applicator's workmanship applied to that Samafil Membrane, except as provided in the following paragraph three (3) Owner's remedies and Sika Samafil's liability shall be limited to Sika Samafil's repair of the Roofing Membrane, Samatherm Insulation or Accessory. 3. This warranty does not apply and may be null and void if any of the following occur: (a) The Roofing Membrane, Samatherm Insulation or Accessory is damaged by a natural disaster including, but not limited to, earthquake, lightning, hail, windstorm in excess of 60 mph (97 km/h), hurricane, or tornado, or: (b) The Roofing Membrane, Samatherm Insulation or Accessory is damaged by any act of negligence, accident, or misuse including, but not limited to, vandalism, falling objects, civil disobedience, or act of war, or: (c) A deficient pre-existing condition or equipment is causing water entry, or: (d) Metal work or other accessories or equipment is used in the Roofing and causes Teaks, or. (e) There are any alterations or repairs made on or through the completed roof, or objects such as but not limited to fixtures, equipment, or structures are placed on or attached to the completed roof without first obtaining written authorization from Sika Samafil, or. (f) Failure by the Owner or his lessee to use reasonable care in maintaining the roof as described in the Owner's Guide provided with this warranty, including that of sealants and caulking, or: (g) Loss of integrity of the building envelope and, or structure including, but not limited to partial or complete loss of roof decking, wall siding, windows, doors or other envelope components or from roof damage by wind blown objects, or: (h) Condensation accumulates in the roof assembly due to incorrect design or due to a reduction in the vapor barrier effectiveness, or: (i) A significant change in the use of the building by the Owner or his lessee expected by Sika Samafil to affect the Roofing Membrane as originally installed, or. (j) The Roofing Membrane is damaged by contaminates and/or spills, or: (k) Deficient design applied to the Roofing Membrane such as membrane contact with incompatible materials and/or substrates, or. (1) The Owner fails to comply with every term and condition stated herein. 4. During the period of this warranty, Sika Samafil, its agents and employees, shall have free access to the roof during regular business hours. 5. Should the Roofing Membrane be concealed, the cost of exposure of the Roofing Membrane for purposes of Sika Samafil's investigation and/or repair, such as removal and replacement of any paving or overburden, shall be the Owner's responsibility. 6. Sika Samafil shall have no obligation under this warranty until all invoices for materials, installation, and services have been paid for in full. 7. Sika Samafil's failure at any time to enforce any of the terms or conditions stated herein shall not be construed to be a waiver of such provision. 8. This warranty is extended solely and exclusively to the owner el the Building at the time the Samafil Roofing System is installed. It does not extend nor is it otherwise assignable or transferable to any other party unless approved in advance and in writing by Sika Samafil and the costs to process the transfer and to inspect and repair the Sika Sarnafil Roofing System, if necessary, are paid for by the original owner. 9. The Owner and Sika Samafil hereby agree that any and all claims (contractual, statutory, common law or otherwise), disputes, or suits that in any way, directly or indirectly, arise out of or relate to this Warranty, or the alleged breach thereof, or to any contracts between the owner and Sika Sarnafil, or the alleged breach thereof, or to the design, manufacture, sale, distribution, installation, and/or inspection of the Sika Samafil Roofing System, shall first be submitted to non-binding mediation before a neutral mediator jointly selected by the parties or, in the absence of agreement, as designated by the American Arbitration Association. In the absence of resolution by mediation, all such claims shall be settled by arbitration by the American Arbitration Association in accordance with the Construction Industry Arbitration Rules. Any such mediation and/or arbitration shall take place in Boston, Massachusetts. This Warranty, and any claims, disputes or suits between the parties hereto shall be govemed by, and construed and enforced in accordance with, the laws of the Commonwealth of Massachusetts. 10. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THERE ARE NO WARRANTIES THAT EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. THE REMEDIES STATED HEREIN ARE EXCLUSIVE REMEDIES AND SIKA SARNAFIL SHALL NOT BE RESPONSIBLE OR LIABLE FOR ANY INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES INCLUDING THE PRESENCE OF MOLDS, FUNGI, BACTERIA, SPORES, MYCOTOXINS OR THE LIKE OR FURTHER LOSS OF ANY KIND WHATSOEVER, INCLUDING BUT NOT LIMITED TO, DAMAGE TO THE BUILDING ON WHICH THE COMPONENTS OF THE ROOF ARE SITUATED, DAMAGE TO THE CONTENTS THEREOF, LOSS OF USE OF THE BUILDING OR ANY COMPONENT PART THEREOF, OR DAMAGE TO ANY OTHER PROPERTY OR PERSONS. NO REPRESENTATIVE OF SIKA SARNAFIL HAS AUTHORITY TO MAKE ANY REPRESENTATIONS OR PROMISES EXCEPT AS STATED HEREIN. RECEIVE Com(:. By: Steven Shaver MAR 26 2614 55 This Warranty Is Effective From: 2/1/2014 through: 2/1/2034 Rdy," 1 /bidLAI FILL: COPY Permit No. Plan review approval is subject to errors and omissions. - ��.' of construction documents does not authorize a my adopted code or ordinance. Receipt f)i approved Fiord Copy and con ons Is acknowledged: By Date: ��a`� f3 City Of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of _a,1/4,.., la Building Division. ! 'r,- -.Y 3833 will require a new plan submittal .... : rtl;:;‘i i^:,°ude additional plan review fees. SEPARATE PERMIT FlEQUIRED FOR: artlebbanical QrgIectrfcai &Plumbing was Piping f Tukwila :71 DIVISION REVIEVVED FOR CODE COMPLIANCE APPROVED OCT 21 2013 317 RECEIVED CITY OF TUKWILA zap PERMIT CENTER :Jr \� (i `V %/\\ r/ STRUCTURAL ENGINEERS Engineers Northwest Inc., P.S. April 10, 2013 ALCO INVESTMENT COMPANY PO Box 3546 Seattle, Washington 98102 Attn: Adam Rosen FILE CO°Y prwrfrlt RE: 17500 West Valley Building — Tukwila, WA New Roofing Layer ENW Project No. 13000027 Adam: �REVIEWED FOR .tbDE COMPLIANCE APPROVED OCT 21 2013 CiN of Tukwila i VLOING DIVISION It is my understanding that you are anticipating adding a new layer of roofing over an existing single layer. As you know, the roof structure is 1/2 inch plywood over 2 x 4 stiffeners at 24 inches on center spanning to 4 x purlins at 8 feet on center. These purlins span about 20 feet to large glue lam beams. It is my also my understanding that the new layer of roofing will weigh about 0.8 pounds per square foot. Section3404.3 of the 2009 IBC allows for a 5 % increase of the design gravity load on the roof without modification to the original structural members. As you are adding only about 2%, it is my opinion that adding the new roofing layer is allowable per current building codes. Please feel free to call me if you have any questions. Sincerely, ENGINEERS NORTHWEST, INC., P.S. Dale Kaemingk, P.E., S.E. Vice President We get DK:bs buildings built. RECEIVED CITY OF TUKWILA 0C- 1 2013 PERMIT CENTER o o 0 0 0 0 0 o e o 0 0 o U o Q 9725 Third Ave NE, Suite 207 • Seattle, WA 98115 206.525.7560 • fax 206.522.6698 www.englneersnw.com Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofino.com WAY' I'ti ROM W(1, 1\(.. 4 -_it III' 111' SUMNER. WA SUBMITTALS PVC Membrane Roofing IFRLE COPY PROJECT 17500 West Valley Highway Building 17500 West Valley Highway Tukwila, Wa PREPARED FOR Rosen investment Company 27402 72nd Avenue South Kent, Wa REVIEWED FOR CODE COMPLIANCE APPROVED OCT 2 2013 pity of Tukwila iHLDING DIVISION October 3rd 2013 RECEIVED CITY OF TUKWILA OCT 20M PERMIT CENTER WRI PROJECT 13-068 SUMNER (253) 863-4455 SEATTLE (206) 575-0078 FAX (253) 863-8311 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofina.com t1'AY�I'S It(K)11%l:, 1\L. lily III' SUMNER. WA 17500 West Valley Highway Building ROOF DRAWING 1 ■ Roof Plan ■ Roof System Description PRODUCT DATA 2 ■ Roof System Product Data CERTIFICATION 3 ■ Approved Applicator Letter ■ UL Rating WARRANTIES ■ Manufacturer's Sample Warranty ■ Contractor's Sample Warranty 4 October 3rd, 2013 WRI PROJECT 13-068 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavn esroofinq.com K'AVNI'S ROOF I%(,. I%( . 111r 111' SUMNER. WA DRAWINGS 1 0 0 M 140'-0" 0 New Scupper Location ROOF LEGEND 0 New Skylight Heat Stack Area of Removed Roofing and Infill Scupper P Existing Roofing N.I.C. 0 0 0 0 0 0 0 0 ITO 0 0 0 O 0 00 0 0 Antenna To Be Demolished 0 0 Eg 0 0 6" Fluid Applied Coating on Duct Transition, Per Drawings Demo Abandoned Conduit Office Roof Sheet Metal Related Work Under Separate Submittal Clean Roof Debris Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 Sum (253) 863-4455 Sea (206) 575-0078 Fax (253) 863-8311 17500 West Valley Highway Building Roof Plan Date 10-3-13 Drawn By Gabriella Aguirre Rev. No. 13-068 Scale N.T.S. Section Sheet 8' - 0" Insulation Data Bottom 1 Middle Top 0 •TYPE Notes: M•ANUFACTURER N/A N/A Sarnafil N/A N/A Sarnrm Roof a e H THICKNESS N/A N/A %,, Field Layout 6 FAST/BD 8' - 0" R - VALUE N/A N/A 2.5 0 a •. • NO. OF LAYERS N/A N/A Single ATTACHMENT N/A N/A Mechanically Fastened FASTENER TYPE N/A N/A XP Perimeter Layout 10 FAST/BD 8' - 0" FASTENER LENGTH N/A N/A 3" BOARD SIZE N/A N/A 4' x 8' 6 v • . . . • FIELD FASTG N/A N/A 6 FAST/BD PERIMETER FAST'G N/A N/A 10 FAST/BD Corner Layout 16 FAST/BD CORNER FAST'G N/A N/A 16 FAST/BD FM REQ. (Pattern Only) N/A N/A N/A INSULATION FASTENING PATTERN S327 PVC Membrane (Induction Welded) _///_////l' '/2" Saranatherm Roof Board H (Mechanically Fastened) fi.. Existing Built-Up Roofing (Removed At Locations Shown on Roof Plan Only) Plywood Deck (Existing) BASE FLASHING COMPONENTS 1 G459 PVC Membrane Samacol 2170 Adhesive s o Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 Sum (253) 863-4455 Sea (206) 575-0078 Fax (253) 863-8311 17500 West Valley Highway Building System Description Date 10/3/13 Drawn By ETP Rev. Job No. 13-068 Scale N.T.S. Section Sheet 002 PRISMATIC ACRYLIC 100% IMPACT MODIFIED OUTER DOME PRISMATIC ACRYLIC INNER DOME CONDENSATE PROVISION SANTOPRENE THERMOPLASTIC GASKET (UL LISTED) CONDENSATE WEEP HOLES - SEALANT (BY OTHERS) ALUMINUM CURB FRAME -- ROOFING (BY OTHERS) QUASAR PRISMATIC ALUMINUM TRIARCH w/THERMAL BARRIER BREAK CURB MOUNTED SKYLIGHT BRISTOUTE PRISMATIC GLAZING HAS BEEN LOAD TESTED AND COMPLIES WITH OSHA - CFRS FOR FALL PROTECTION. BLACK BUTYL TRIARCH OUTER DOME SEALANT POLYVINYL CHLORIDE (PVC) THERMAL BARRIER BREAK (UL/FM CODE COMPLIANT) INSIDE CURB DIMENSIONS POLYURETHANE SEALANT - ALUMINUM RETAINER CAP FASTENERS (BY OTHERS) 1-1/2" WIDE ROOF CURB (BY OTHERS) ►- - - -- 5/8" FLASHING CLEARANCE MODEL: ALB -CM -2 -PM -PM (NOT TO SCALE) OUTER PRISMATIC COLOR X CLEAR (CPM) WHITE (WPM) OTHER: INNER PRISMATIC COLOR - CLEAR (CPM) x WHITE (WPM) OTHER: FRAME FINISH BRONZE ANODIZED (BA) CLEAR ANODIZED (CA) X' MILL FINISH (MF) s WHITE PAINT (WP) OTHER: SPECIFICATIONS VLT: SHGC: U FACTOR: MODEL INSIDE CURB NUMBER DIMENSIONS SQUARE 1414 -ALB -Q+1 141/4" x 14 1/4" 1919 -ALB -G1 19" x 19" 2222 -ALB -CM +22 1/4" x 22 1/4" 3030-AL&01 30 1/4" x 30 1/4" 3737 -ALB -CM 37' x 37" 4242 -ALB -04 42"x 42" 4646 -ALB -CM 46 1/4" x 46 1/4" 4848 -ALB -al +48" x 48" 5555 -ALB -al 55" x 55" 6060 -ALB -04 '60"x 60" CAU. FOR ADDITIONAL SUES Q MODEL INSIDE CURB NUMBER . DIMENSIONS 'IRECTANGLE 1422 -ALB -CM 141/4" x22 1/4" 1446 -ALB -CM 141/4"x46 1/4" 2230 -ALB -a4 22 1/4" x 30 1/4" 2237-ALBLM 22 1/4" x 37" 2246 -ALB -04 22 1/4" x 46 1/4" 2272 -ALB -04 22 1/4" x 72" 2296 -ALB -CM 22 1/4" x 96" 2448 -ALB -CM 24 1/4" x 48" 12496 -ALB -CM 24 1/4" x 96" x037 -ALB -Q4 301/4" x 37' 3046-AL&Q4 '30 1/4"x46 1/4" 3069-AL&07 130 1/4" x 69 1/2" 3096-AL&01 +301/4" x 96" 3496 -ALB -Q4 34" x 96" + i 3696 -ALB -CM 36" x 96" - 1- QN MODEL INSIDE CURB NUMBER_ DIMENSIONS RECTANGLE - (Dont.) 36120 A1B-01 36" x 120" 3746 -ALB -CM 37"x46 1/4" 3775 -ALB -CM 37" x 75" 3859 -ALB -CM 38"x 59" 4669 -ALB -a+'1 46 1/4" x 69 1/2" 4689 -ALB -CM 46 1/4" x 89 1/2" 4872 -ALB -CM -48= x 72" 114884 -ALB -04 48" x 84" 4896 -ALBA 48"x96" 48120 -ALBA 48"x 120" 5460 -ALB -CM 54" x 60" 6072 -ALB -CM 160" x 72" 6084 -ALB -CM 60" x 84' 6096 -ALB -al 60" x 96' 60120 -ALB -CM ; 60" x 120" I QTY - 18 Bristolite lJaylighting Systems 401 East Goetz Avenue, Santa Ana, CA. 92707 TEL 714.540.8950 / FAX 714.540.5415 CUSTOMER: WAYNES ROOFING PREPARED BY: Gary Stella JOB No.: PROJECT: 17500 WEST VALLEY HWY SUBMITTAL DATE: 10/2/2013 SHEET NO.: DWG. LOCATION: X:\ASHARED\LNGR\DEPT\ACAD DRAWINGS \Submitt\Brtstd\ResidentW9V1LB-C'1-2-PM-PM.dwg UMPCO CLIP. SEE ENGLARGEMENTS i - OUTSIDE CURB DIMENSION - - INSIDE CURB DIMENSION +0" -1/4" 1 I I UMPCO CORROSION RESISTANT CUPS WITH 7/32" dia. HOLE 45 32" CRS. TYP. 12" CRS. TYP. tr I _ EXISTING CURB GLADIATOR SAFETY SCREEN WELDED JOINTS - TYP. INSIDE CURB DIMENSION T - OUTSIDE CURB DIMENSION R7 6An 18n 1 n 32 00.162" GALVANISED. STEEL WIRE MESH - TYP. 117 32 i. - 1516n PLAN ON CUP ELEVATION 12,, 516 MODEL: X)00(-SSCRN SCALE(S): 1":20" & 1":2" MODEL DIMENSIONS QTY MODEL DIMENSIONS QTY MODEL DIMENSIONS QTY NOTES: 1. BRISTOLITE DROP-IN SAFETY SCREENS ARE ALL GALVANIZED STEEL THEY ARE DESIGNED TO BE INSTALLED BEFORE THE BRISTOLITE SKYLIGHT OR SMOKE HATCH IS SET IN PLACE. 2. SAFETY SCREEN: 4" x 4" GRID PATTERN, OSHA COMPLIANT PER 29 CFR ss. 1910.23 & ss. 1926.501. SQUARE 'RECTANGLE 1414-SSCRN T13 3/4" x 13 3/4" T 2230-SSCRN 121 3/4" x 29 3/4" 1919-SSCRN 118 1/2" x 18 1/2" 12237-SSCRN 1213/4" x 36 1/2" 2222-SSCRN 21 3/4" x 213/4' 2246-SSCRN +21 3/4" x 45 3/4" 3030-SSCRN 29 3/4" x29 3/4" 2272-SSCRN 21 3/4" x 71 1/2" 3737-SSCRN +36 1/2" x 36 1/2" +2296-SSCRN 21 3/4" x 95 1/2" 4242-SSCRN 41 1/2" x 41/2" 037-SSCRN 29 3/4" x 36 1/2" 4646-SSCRN 45 3/4" x 45 3/4" ' 3046-SSCRN 29 3/4" x 45 3/4' 4848-SSCRN 47 1/2' x 471/2'1 3069-SSCRN +29 3/4" x 69" 5555-SSCRN 541/2" x 54 1/2" 13096-SSCRN +_29 3/4" x 95 1/2" 6060-SSCRN +591/2" x 59 1/2" }3496-SSCRN 33 1/2" x 95 1/2" CAU. FOR ADDITIONAL SIZES 136120-SSCRN , 35 1/2" x 119 1/2" + + RECTANGLE - T3746-SSCRN 3775-SSCRN 13859-SSCRN 14669-55CRN 4689-SSCRN 4896-SSCRN 48120-SSCRN 5460-SSCRN 16072-SSCRN 6096-SSCRN (coni.) 36 1/2" x 45 3/4" X36 1/2" x 74 1/2" 1'37 1/2"x58 1/2" 45 3/4" x 69" 45 3/4"x89" 47 1/2" x 95 1/2" 18- 47 1/2" x 119 1/2" 53 1/2" x 59 1/2" 59 1/2" x 71 1/2" 59 1/2" x 95 1/2" CALL FOR ADDIRONAL SIZES Bristolit• e-aylighting Systems 401 East Goetz Avenue, Santa Ana, CA. 92707 TEL 714.540.8950 / FAX 714.540.5415 CUSTOMER: WAYNES ROOFING PREPARED BY: Gary Stella JOB No.: PROJECT: 17500 WEST VALLEY HWY SUBMITTAL DATE: 10/2/2013 SHEET NO.: DWG. LOCATION: X:\ASHARED\ENGR\DEPT\ACAD DRAWINGS\Submitt\Bristol ndust\Gladiator\1000(-SSCRN.dwg Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wayn es roofi n p. com WAY%I'S RII01 I%(i, I%(.. r III r 111" 111' SUMNER. WA PRODUCT DATA 2 Product Data Sheet Edition: 09/2012 Version no.: 0001 Sarnatherm Roof Board -H Overview: Sarnatherm Roof Board -H is a lightweight, high-density polyisocyanurate roof board for new, re-cover and re -roof applications. The coated fiber glass facers provide strong, smooth surfaces suitable for mechanically at- tached or fully adhered membranes. Composition: Sarnatherm Roof Board -H is high-density polyisocyanurate with fiber glass - reinforced facers. Sarnatherm Roof Board -H is provided in a 4 ft. x 8 ft. (1.2 m x 2.4 m) board size and in a thickness of 1/2 inch (13 mm). Features: • Lightweight for easy hoisting, staging and maneuvering • High impact and flexural strength • Improved resistance to foot traffic and normal roof maintenance • Low water absorption • Easy scoring, cutting and snapping • UL Classified 790 • FM Approved (consult RoofNav for specific assemblies) Packaging: Sarnatherm Roof Board -H is packaged 96 pieces per bundle. Weight per sheet is 11 lbs. (4.9 kg). Protect Sarnatherm Roof Board -H from damage and moisture during transportation and storage. Installation: Sarnatherm Roof Board -H is installed by a Sika Sarnafil Authorized Ap- plicator by mechanical -attachment to the roof deck with approved fasteners and plates. Attachment with specialized adhesive(s), options dependent on deck type and Sika Sarnafil system to be installed. Maximize board lengths to minimize end joints with end joints staggered. Drive fasteners firmly against and flush with surface of Sarnatherm Roof Board -H. Sarnatherm Roof Board -H is cut by scoring and breaking. Do not install more Sarna - therm Roof Board -H than can be covered with welded Sarnafil membrane in that day. Availability: Sarnatherm Roof Board -H is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roof System. Contact your Sika Sarnafil Regional Office or visit our website for further information. Warranty: As a Sika Sarnafil supplied accessory, Sarnatherm Roof Board -H is in- cluded in Sika Sarnafil's System Warranty to the Building Owner. Sarnafii® Maintenance: Sarnatherm Roof Board -H requires no maintenance. Technical: Sika Sarnafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation methods of Sarnatherm Roof Board -H. Technical Data (as manufactured): Property Test Method Thickness, nominal Width, standard Length, standard Pieces per pallet Weight per sheet (4x8 sheet) Dimensional Stability ASTM D 2126 "R" Value ASTM C 518 Water Absorption, % max Compressive Strength, Mold Resistance Service Temperature Recycled Content Flame Classification ASTM C 209 ASTM D1621 ASTM D3273 112 13 mm 4' (1220 mm) 8' (2440 mm) 96 11 Ib. <0.5% (linear change 7 days) 2.5 <1% Volume >100psi Passed (10) 260 F or less >8% FM Approved (consult RoofNav for specific assemblies) UL Classified 790 Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.sarnafil.sika.com Email: Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 webmaster.sarnafil@us.sika.com Web: can.sika.com Disclaimer: All information provided by Sika Corporation ("Sika') concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products. nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's most current Technical Data Sheet, product label and Material Safety Data Sheet which are available at usa.sarnafil.sika.com or by contacting 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. Product Data Sheet Edition: 5/2007 Version no.: 0004 Sarnafastener - XP Overview: Sarnafastener-XP is a specially -designed fastener used with Sarnadisc, Sarnadisc-XPN, Sarnarail or Sarnabar to attach the Sarnafil S327 roof membrane directly to (16 - 24 gauge) steel roof decks, approved structural concrete or wood roof decks greater than 15/32 inch and structural con- crete decks. Composition: Sarnafastener-XP is made from carbon steel, treated with a corrosion resistant coating to meet the Factory Mutual 4470 criteria for corrosion resistance. Features: Sarnafastener-XP has an enhanced buttress thread to increase both surface area and friction against the deck for improved backout resistance and exceptionally high pullout values. The shank diameter is approximately 0.21 inch (5.3 mm) and the thread diameter is approximately 0.26 inch (6.6 mm). The driving head has a diameter of approximately 0.435 inch (11 mm) and is #3 Phillips design for positive engagement and simplicity of ap- plication. The thread density is 13 turns/inch (approximately 5 turns/cm). Packaging: Sarnafastener-XP is packaged in boxes or plastic buckets in quantities of 250, 500 or 1000. See Technical Data section for lengths and weights. Installation: For S327 roof membrane attachment, the Sarnafastener-XP is placed through the Sarnadisc, Sarnadisc-XPN. Sarnarail or Sarnabar, through the membrane, insulation and set into the roof deck with a heavy-duty (4 amp min.), variable speed (0-2500 rpm), reversible screwgun with clutch release and a #3 Phillips drive bit. Sarnafastener-XP must penetrate steel, wooden plank and concrete roof decks 1 inch (25mm) and the underside of plywood roof decks % inch (13mm). Pre -drill a 7/32" ANSI pilot hole when installing in structural concrete decks using a hammer or rotary hammer drill. Hole shall be 1/2" deeper than required embedment for concrete decks. Care must be taken to not damage the roof deck. Choose the correct fastener length and do not overdrive or underdrive the Sarnafastener-XP. Pullout tests may be required prior to job start. Contact Sika Sarnafil's Technical Department for determination. Availability: Sarnafastener-XP is available directly from Sika Sarnafil Authorized Ap- plicators when used within a Sika Sarnafil roof system. Contact your Sika Sarnafil Regional Office or visit our website for further information. Sarnafil® Warranty: As a Sika Sarnafil-supplied accessory, Sarnafastener-XP is included in Sika Sarnafil's Standard or System Warranty to the Building Owner. Maintenance: Sarnafastener-XP requires no maintenance. Technical: Sika Sarnafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method of Sarnafastener-XP. Technical Data: Length 1-�/4 inch (32 mm) 2 inch (51 mm) Thread Packaging Weight 1 inch 1000/Bucket 12 Ib 1-% inch 1000/Bucket (5.4 kg) 19 Ib (8.6 kg) 3 inch (76 mm) 2-% inch 100U/bucket 29 Ib (13.2 kg) 4 inch (101 mm) 5 inch (127 mm) 6 inch (152 mm) 7 inch (178 mm) 8 inch (203 mm) *10 inch (254 mm) *12 inch (304 mm) *14 inch (356 mm) *16 inch (406 mm) 2-% inch 3-% inch 3-3/4 inch 3-% inch 3 3/4 inch 3-3/4 inch 3-3/4 inch 3-% inch 3-3/4 inch 1000/Bucket 38 lb (17.2 kg) 1000/Bucket 47 Ib (21.3 kg) 500/Bucket 29 Ib (13.1 kg) 500/Bucket 33 Ib (15.0 kg) 500/Bucket 37 Ib (16.8 kg) 500/Box 46 Ib (20.9 kg) 500/Box 55 Ib (24.9 kg) 500/Box 65 Ib (29.4 kg) 250/Box 38 Ib (17.2 kg) * May be coated with a grey corrosion resistant coating. Corporate Office Sika Sarnafil Inc. 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: www.sikacorp.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: www.sika.ca Disclaimer: The information, and. in particular, the recommendation relating to the application and end-use of Sika Sarnafil products, are given in good faith based on Sika Sarnafil's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika Sarnafil recommendations. 117 practice. the differences in materials, substrates and actual site conditions are such that no war- ranty in respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Sarnafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned. copies of which will be supplied on request. Product Data Sheet Edition: 3/2008 Version no.: 0001 Sarnadisc RhinoBond Overview: Sarnadisc RhinoBond is a specially designed, polymer coated plate used with Sarnafasteners to attach insulation or cover boards directly to the roof deck or structural purlins prior to the installation of the Sika Sarnafil membrane. The membrane will be welded to the Sarnadisc RhinoBond by induction welding. Composition: Sarnadisc RhinoBond is a 3 inch (75 mm) diameter, 0.028 inch (0.7 mm) thick metal plate with a polymer coating, meeting the Factory Mutual 4470 criteria for corrosion resistance. Features: Sarnadisc RhinoBond has a recessed center to provide protection to the membrane underside from abrasion by the fastener head. Packaging: Sarnadisc RhinoBond is packaged in Pails of 500. Each pail weighs ap- proximately 54 lbs (24 kg). Installation: Sarnadisc RhinoBond is positioned on the surface of the insulation board. A Sarnafastener is set through the center of the disc and set into the roof deck or purlin. The Sarnadisc RhinoBond holds the insulation in place. Availability: Sarnadisc RhinoBond is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil roof system. Contact your Sika Sarnafil Regional Office or visit our website for further information. Warranty: As a Sika Sarnafil supplied accessory, Sarnadisc RhinoBond is included in Sika Sarnafil's Standard or System Warranty to the Building Owner. Samafil® Maintenance: Sarnadisc RhinoBond requires no maintenance. Technical: Sika Sarnafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method. Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: www.sikacorp.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: www.sika.ca Disclaimer: The information, and, in particular the recommendation relating to the application and end-use of Sika Sarnafil products, are given in good faith based on Sika Samafil's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika Sarnafil recommendations. In practice. the differences in materials, substrates and actual site conditions are such that no war- ranty in respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Sarnafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Product Data Sheet Edition: 02/2013 Version no.: 0004 m, rgySlnart 9 BOOP` Sarnafil® S327 EnergySmart Roof® Membrane 48 " 60 72 80 Feltback Overview: The S327 EnergySmart Roof membrane is a heat -weldable membrane produced with an integral polyester reinforcement for high strength, for use in a Sika Sarnafil Mechanically -Attached System. Sika S sists o White Energy Star qualified EnergySmart Roof color family con - Tan, Light Gray, and Patina Green. Composition: The S327 EnergySmart Roof membrane is a high-quality, thermoplastic PVC membrane with a polyester scrim reinforcement. The S327 Roof mem- brane has a unique lacquer coating applied to the top of the membrane to reduce dirt pick up. Features and Benefits: • High Strength • Meets EnergyStar/Title 24 Requirements for Cool Roofing (see chart) • Meets LEED/Green Globe Requirements for Cool Roofing (see chart) • Recycled content (see chart) • Lacquer coated to reduce dirt pick up • Hot-air welded seams for long-term performance • Proven membrane performance Codes and Approvals: Sika Sarnafil's Mechanically -Attached Systems using S327 PVC mem- branes are classified by Underwriters Laboratories, Inc., Underwriters Laboratories of Canada, FM Global, Miami -Dade and Florida Building Code. Sika Sarnafil membranes also meet the material requirements of the International building code. For more information, please visit the "tech- nical downloads" section of our website. Packaging: The S327 roof membrane rolls are wrapped in a protective film and strapped to a wood pallet. EnergySmart white, tan and light gray are avail- able as 10 ft. (3 meters) wide. EnergySmart patina green is availale as 6.5 ft. (2 meters) wide. 6.5 ft. rolls weigh between 161 - 195 lbs and the 10 ft. rolls weigh between 265-375Ibs. Weight is dependent on thickness of membrane and/or feltbacking. Installation: S327 Roof membrane is installed by a Sika Sarnafil Authorized Applicator. S327 is rolled out onto the insulation board or acceptable substrate, fas- tened to the roof deck and heat -welded together by trained operators using Sika Sarnafil's hot-air welding equipment. Availability: The S327 Roof membrane is available directly from Sika Sarnafil Autho- rized Applicators. Contact your Sika Sarnafil Regional Office or visit our website for further information. Warranty: Upon successful completion of the installed roof by the Sika Sarnafil Autho- rized Applicator, Sika Sarnafil can provide a Warranty to the Building Owner via the Authorized Applicator. Maintenance: The S327 Roof membrane requires no maintenance. As a prudent pre- ventative measure, Sika Sarnafil recommends that the Owner or that the Owner's designated representative inspect the installed roof system for damage, plugged drains, weathered sealants, etc. at least twice a year and after each storm. Samafil® Technical Support: Sika Sarnafil provides technical support. Please contact your local technical representative or technical manager if you need assistance. Technical Data (as manufactured): ASTM Type III D-4434 Spec. Parameters Reinforcing Material Overall Thickness, mil Thickness Above Scrim, mil Felt Weight oz/yd2 (feltback membrane only) Breaking Strength (M.D.), min., Ibf/in. (KN/m) Elongation at Break, min. Machine Direction Cross Direction % Seam Strength, min., (% of original)* Retention of Properties After Heat Aging Tensile Strength, min., (% of original) Elongation, min., (% of original) Tearing Strength (C.D.), min., Ibf (N) Low Temperature Bend, -40 °F (-40 °C) Accelerated Weathering Test (Florescent Light, UV exposure) Cracking (7x magnification) Discoloration (by observation) Crazing (7x magnification) Linear Dimensional Change (C.D.), Weight Change After Immersion in Water, % Static Puncture Resistance, 33 Ibf (15 kg) Dynamic Puncture Resistance, 14.7 ft-Ibf (20 J) Recycled Content (10' & 5' sheet only) ASTM Test Method Requirement 4$ Polyester 48 tyuu w rnystt.d Properties $Q Polyester 80 -- -- D751 45 SQ Polyester 60 72 Polyester 72 -- 16 24 30 36 40 -- -- 9 9 9 9 D751 200(35) 295 305 315 325 D751 15 27.5 28.5 29 29.5 15 28.5 29.5 30 30.5 D751 75 Pass Pass Pass Pass D3045 D751 90 Pass Pass Pass Pass D751 90 Pass Pass Pass Pass 01004 45 (200) 47 48 48.5 49 D2136 Pass Pass Pass Pass Pass G154 5,000 Hours 10,000 Hours 10,000 Hours 10,000 Hours 10,000 Hours None None None None None Negligible Negligible Negligible Negligible Negligible None None None None None D1204 0.5% max. -0.10 -0.12 -0.13 -0.14 D570 ± 3.0% max. 2.2 2 1.8 1.8 D5602 Pass Pass Pass Pass Pass D5635 Pass Pass Pass Pass Pass 9% Pre-Cnnsumer / 10/r, Post -Consumer * Failure occurs through membrane rupture not seam failure. Initial Solar 3 Year EnerovSmart Colors Reflectance Reflectance EnergySmart White *1 EnergySmart Tan *1 EnergySmart Light Grey *2 EnergySmart Patina Green *2 0.83 0.73 0.50 0.55 0.63 0.65 0.44 0.46 Initial Thermal Emittance 0.90 0.85 0.84 0.86 3 Year Thermal Initial Solar Emittance Reflectance Index 0.86 0.86 0.85 0.85 104 89 56 64 3 Year Solar Reflectance Index 75 78 49 51 *1 Sika Sarnafil EnergySmart White and Tan membranes meet ENERGY STAR®, LEED, Green Globes and California's Title 24 criteria for Low and Steep Slope applications. *2 Sarnafil EnergySmart Light Grey and Patina Green membranes meet ENERGY STAR®, LEED and Green Globes criteria for Steep Slope applications. EnergySmart Light Grey meets California's Title 24 criteria for Steep Slope applications. EnergySmart Patina Green meets Title 24 criteria for steep slope applications with a 3 year calculated value of 0.445 when using Title 24's aged reflectance equation. Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com MIAMI OADE COUNTY APPROVED Miami -Dade County Product Control Approved Disclaimer: The information, and. in particular, the recommendation relating to the application and end-use of Sika Sarnafil products, are given in good faith based on Sika Sarnafil's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika Sarnafil recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Sarnafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. CR C ROOF Canada Office Sika Sarnafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1 L5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com ENERGY STAR for roofing products is only valid in the United States Product Data Sheet Edition: 04/2012 Version no.: 0007 At Base Flashings Only Sarnafil G459 Flashing Membrane Overview: Sarnafil G459 flashing membrane is a heat -weldable roofing membrane for- mulated for direct exposure to the weather and is produced with an integral fiberglass mat reinforcement for dimensional stability. G459 flashing mem- brane is used to flash roof penetrations within Sarnafil Express, Sarnafast®, Engineered and Adhered roofing systems. G459 flashing membrane can be adhered directly to asphalt -contaminated surfaces, Composition: G459 flashing membrane is a high quality product containing PVC resin, pigments, stabilizers, ultraviolet absorbers, and a fiberglass carrier sheet. Sarnafil G459 Flashing Membrane comes in 12" lengths and is 60 mil (1.5) Thick. The standard color is white. Features: The manufacturing process causes G459 flashing membrane to have no built-in stress at time of production and to have a fully -encapsulated reinforcement with no risk of delamination or water -wicking. G459 flashing membrane is thicker than many competitive products which can improve weldability and service life. G459 flashing membrane is highly dimensional- ly stable making it ideal for adhered flashing applications at walls, termina- tions and penetrations. G459 flashing membrane is resistant to asphalt and many other rooftop contaminates. Either side of G459 flashing membrane can be exposed to weather conditions which allows it to cover rooftop con- taminates or act as a sacrificial layer for contaminates being emitted onto the roof. Sika Sarnafil recommends testing for compatibility. Contact Sika Sarnafil's Corporate or Regional Offices. Codes and Approvals: Sika Sarnafil's Adhered Systems using G410 PVC membranes are clas- sified by Underwriters Laboratories, Inc., Underwriters Laboratories of Canada, FM Global, Miami -Dade and Florida Building Code. Sika Sarnafil membranes also meet the material requirements of International building code. Packaging: G459 flashing membrane rolls are provided individually and are sealed for shipping. Individual rolls are 168 lbs for 6.56 ft x 65 ft and 83 lbs for 3.25 x 65 ft. Installation: G459 flashing membrane is installed by Sika Sarnafil Authorized Applicators on walls curbs and certain other penetrations using Sika Sarnafil's Sarnacol adhesives. The seams are then heat welded together by trained operators using Sika Sarnafil's hot-air welding equipment. Availability: G459 flashing membrane is available directly from Sika Sarnafil Authorized Applicators. Contact your Sika Sarnafil Regional Office or visit our website for further information. Sarnafil® Warranty: As a Sika Sarnafil-supplied accessory, G459 flashing membrane is included in Sika Sarnafil's Standard or System Warranty to the Building Owner. Maintenance: G459 flashing membrane requires no maintenance. Technical: Sika Sarnafil provides technical support. Technical staff is available to advise Applicators as to the correct installation methods of G459 flashing membrane. Technical Data (as manufactured): Parameters Reinforcing Material Overall Thickness, min., inches (mm) Tensile Strength, min., psi (MPa) Elongation at Break, min. Seam Strength", min., (% of tensile strength) Retention of Properties After Heat Aging Tensile Strength, min., (% of original) Elongation, min., (% of original) Tearing Resistance, min., Ibf (N) Low Temperature Bend, -40 °F (-40 °C) Accelerated Weathering Test (Florescent Light, UV exposure) Cracking (7x magnification) Discoloration (by observation) Crazing (7x magnification) Linear Dimensional Change Weight Change After Immersion in Water Static Puncture Resistance, 33 lbf (15 kg) Dynamic Puncture Resistance, 7.3 ft-Ibf (10 J) ASTM Test Method D638 D638 D638 D638 D3045 D638 D638 D1004 D2136 G154 D1204 D570 D5602 D5635 Typical Physical Properties Fiberglass 0.060 (1.5) 1600 (11.1) 270% M.D. 250% C.M.D. 80 95 90 14 (63.0) Pass Pass None Negligible None 0.02% 2.5% Pass Pass * Failure occurs through membrane rupture not seam failure. Disclaimer: All information provided by Sika Corporation ("Sika') concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products. is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions. actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice. recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice. recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or by calling 800-451-2504. Prior to each use of any Sika product. the user must always read and follow the wamings and instructions on the product's most current Technical Data Sheet, product label and Material Safety Data Sheet which are available at usa.sarnafil.sika.com or by contacting 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the wamings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Product Data Sheet Edition: 04/2013 Version no: 0015 At Base Flashings Only Sarnacol® 2170 Adhesive Overview: Sarnacol® 2170 is a solvent -based reactivating adhesive used with a Sika Sarnafil Adhered system and/or flashing detail. It is also used to adhere flash- ings in Sarnafil waterproofing systems. It is formulated for adhering Sarnafil PVC membranes to properly prepared substrates such as wood, sheet steel, masonry, concrete and approved coverboards. Composition: See Material Safety Data Sheet for information. VOC Content: 694.2 g/L Features: Sarnacol 2170 is uniquely formulated to be compatible with Sarnafil membranes. Packaging: Sarnacol 2170 is supplied in 5 gal (18.9 L) steel containers weighing 45 lbs (20.4 kg). The shelf life is 12 months in a tighly closed container in tempera- tures between -4°F (-20°C) and 86°F (30°C). Installation: Bareback: Sarnacol 2170 is roller -applied to both the membrane and substrate in the fol- lowing manner: Apply Sarnacol 2170 to the substrate and allow to dry. After the substrate adhesive has dried completely, apply Sarnacol 2170 to the back side of the membrane, and allow to become tacky (producing strings) when touched with a dry finger. The Sarnacol 2170 on the membrane shall not be permitted to dry completely. The membrane is then placed on the substrate (mating adhesive surfaces). The bonded sheet shall be pressed firmly in place with a minimum 100 Ib (45 kg) steel, membrane roller, by rolling in two directions (vertical flashings are hand -rolled). Feltback: Sarnacol 2170 is roller -applied to the substrate and allowed to dry completely. A second coat of adhesive is then applied to the substrate. The second coat of adhesive shall not be permitted to dry completely. The membrane is then placed on the substrate while the adhesive is still wet. The bonded sheet shall be pressed firmly in place with a minimum 100 Ib (45 kg) steel, membrane roller, by rolling in two directions. Availability: Sarnacol 2170 is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roofing or Waterproofing System. Contact Sika Sarnafil or visit our website www.sikacorp.com for further information. Warranty: As a Sika Sarnafil-supplied accessory, Sarnacol 2170 is included in Sika Sarnafil's Standard or System Warranty. Maintenance: Sarnacol 2170 requires no maintenance. Technical: Sika Sarnafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Sarnafil® Technical Data: Substrate Isocyanurate Organic Facer Isocyanurate Glass Facer Smooth Plywood Metal Concrete Wall DensDeck® DensDeck Prime® DensDeck® Duraguard Securock® Gypsum Fiber Total Rate for Bareback Membrane 1-% gallons per square (0.71 liters/meter') 1-1/2 gallons per square (0.61 liters/meter') 1-1/2 gallons per square (0.61 liters/meter') 1-1/4 gallons per square (0.51 liters/meter') 1-% gallons per square (0.71 liters/meter') 1-3/4 gallons per square (0.71 liters/meter') 1-'/2 gallons per square (0.61 liters/meter') 1-1/2 gallons per square (0.61 liters/meter') 1-'/4 gallons per square (0.51 liters/meter') Substrate Isocyanurate Organic Facer Isocyanurate Glass Facer Smooth Plywood Metal Concrete Deck Concrete Wall Masonry Wall Cellular Concrete (feltback membrane only) DensDeck® DensDeck Prime® DensDeck Duraguard® Securock® Gypsum Fiber Total Rate for Feltback Membrane 2-1/4 gallons per square (0.92 liters/meter') 2 gallons per square (0.81 liters/meter') 2 gallons per square (0.81 liters/meter2) 1-3/4 gallons per square (0.71 liters/meter') 2-1/4 gallons per square (0.92 liters/meter2) 2-1/4 gallons per square (0.92 liters/meter2) 2-1/4 gallons per square (0.92 liters/meter') 2-1/4 gallons per square (0.0.92 liters/meter') 2-% gallons per square (0.92 liters/meter') 2 gallons per square (0.81 liters/meter') 2 gallons per square (0.81 liters/meter') 1-3/4 gallons per square (0.71 liters/meter') Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1L5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: The information, and, in particular, the recommendation relating to the application and end-use of Sika Sarnafil products, are given in good faith based on Sika Sarnafil's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika Sarnafil recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no war- ranty in respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Sarnafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Product Data Sheet Edition: 6/2009 Version no: 0004 Sikaflex° - 1 a Overview: Sikaflex-la is a premium -grade, high-performance, moisture -cured, one - component polyurethane -based, non -sag elastomeric sealant used in cer- tain Sika Sarnafil roofing or waterproofing system flashing details. Typical applications include wall, curb and drain terminations. It is also used as a sealant at pipe penetrations and under certain metal flashings. Composition: See Material Safety Data Sheet for Composition. Sikaflex-la cures to a light gray color with a smooth texture. VOC Content: 40 g/L Features: Sikaflex-la bonds well to Sika Sarnafil PVC membranes and to common building materials. It is easy to apply and has excellent workability charac- teristics. Sikaflex-la is USDA -approved, NSF -approved for potable water contact, jet fuel resistant and has high elasticity curing to a tough, durable, flexible consistency with exceptional cut and tear resistance. It meets Federal Specification TT -S -0023C, Type H, Class A. It is paintable with water-, oil - and rubber -based paints. Sikaflex-la is VOC compliant in California and has excellent weatherability and resistance to degradation by ultraviolet light. Packaging: Sikaflex-la is packaged in 10.3 fluid oz (305 ml) disposable cartridges (24 per case). A cartridge covers approximately 15 linear ft (4.6 m) based on a 3/8 in (9.5 mm) bead. The actual coverage rate will vary depending on the size of the bead. A case weighs 25 lbs (11.3 kg). The shelf life is 15 months in an unopened cartridge. Installation: The recommended application temperature for Sikaflex-la is between 40°F (4°C) and 100°F (38°C). For cold weather applications, condition cartridges at approximately 70°F (21°C) and maintain that temperature until just prior to use. Do not apply over damp surfaces as this will affect adhesion and may lead to bubbling within the sealant. Clean all surfaces. Substrate must be sound, clean, dry, frost -free, and free of oil and grease. Sarnafil® Installation (cont): Use with adequate ventilation. Sikaflex-la is easy to apply with conven- tional caulking equipment. Avoid air entrapment when applying sealant. Do not tool with detergent or soap solutions. Material becomes tack free in about 3-4 hours. Final cure is achieved in 4- 7 days depending on temperature and humidity. Avoid contact with alcohol and other solvent cleaners during cure. Use open cartridges the same day. Store the material in a dry area be- tween 40°F (4°C) and 95°F (35°C). Availability: Sikaflex-la is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roofing or Waterproofing System. Con- tact Sika Sarnafil or visit our website www.sikacorp.com for further informa- tion. Warranty: Sika Sarnafil will replace defective Sikaflex-la material provided the defect is identified by the Sika Sarnafil Authorized Applicator and acknowledged by Sika Sarnafil during the time of original installation and application. Main- tenance of this sealant or of any other sealant after original installation and application is not covered by Sika Sarnafil's Warranty. Maintenance: Sikaflex-la must be maintained. Sika Sarnafil recommends that the Owner or Owner's designated representative inspect the sealant at least twice a year and after each storm. Technical: Sika Sarnafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Technical Data: Material and curing conditions @ 73°F (23°C) and 50% R.H. Shelf Life Service Range Curing Rate Tear Strength Shore A Hardness Tensile Properties Elongation at Break Tack -free Time Tack -free to Touch Final Cure ASTM D-624 ASTM D-2240 ASTM D-412 Chemical Resistance 15 months -40°F (-40°C) to 170°F (77°C) 4 hours 3 hours 4 to 7 days 55 Ib/in (9.6 N/mm) 40±5 @ 21 days Tensile Stress @ 21 days 175 psi (1.21 MPa) 550% Good resistance to water and diluted acids and alkalines Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: www.sikacorp.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: www.sika.ca Disclaimer: The information, and, in particular. the recommendation relating to the application and end-use of Sika Sarnafil products, are given in good faith based on Sika Sarnafil's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika Sarnafil recommendations. In practice. the differences in materials, substrates and actual site conditions are such that no war- ranty in respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Sarnafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Product Data Sheet Edition: 2/2013 Version no.: 0007 Sarnaclad Used at Scuppers Only Overview: Sarnaclad is a heat -weldable flashing product used with Sarnafil G and S membranes to form a monolithic roofing or waterproofing system. Composition: Sarnaclad is a 24 gauge, G90 galvanized metal sheet with a 20 mil (0.5 mm) unsupported Sarnafil membrane laminated on one side. Sarnaclad is available in seven standard colors. Standard colors are Copper Brown, White, Evergreen, Lead Gray, Light Gray, Patina Green, and Tan. Sika Sar- nafil's Energy Star rated EnergySmart Roof® color family consists of White, Tan, Light Gray, and Patina Green. The dimensions of Sarnaclad are 4 ft x 8 ft (1.2 m x 2.4 m) or 4 ft x 10 ft (1.2 m x 3.0 m). Recycled Content (metal): 25% Post Consumer, 6% Pre Consumer Recycled Content (membrane): 0% Features: Sarnaclad is a durable and attractive flashing product capable of being formed into a large variety of shapes and profiles. Heat -welding of Sar- nafil G and S membranes to Sarnaclad assures watertight integrity. The Sarnaclad has a unique lacquer coating to resist staining from airborne dirt and pollutants. Packaging: See Technical Data section for information. Installation: Sarnaclad is cut to size and formed to shape on standard sheet metal equipment. Sarnaclad is fastened in position in accordance with Sika Sar- nafil Technical requirements. The Sarnaclad joints are covered by 2 inch (50 mm) wide aluminum foil tape and then made watertight by heat -weld- ing a 4 inch (100 mm) wide G410 membrane strip over the tape. By use of a Sarnafil G or S coverstrip, the roofing or waterproofing membrane is then heat -welded to the Sarnaclad. Availability: Sarnaclad is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil roofing or waterproofing system. Contact your Sika Sarnafil Regional Office or visit our website for further informa- tion. Warranty: As a Sika Sarnafil-supplied accessory, Sarnaclad is included in Sika Sarnafil's Standard or System Warranty to the Building Owner. Sarnafii® Maintenance: Sarnaclad requires no maintenance. Technical Data: Sika Sarnafil provides technical support. Technical staff is available to ad- vise Applicators as to the correct installation method of Sarnaclad. Sheets/Pallet Size 25 4ftx8ft (1.2 m x 2.4 m) 25 4 ft x 10 ft (1.2mx3.0m) Weight/Sheet Weight/Pallet 35 lbs (16 kg) 905 lbs (410.5 kg) 44 lbs (20 kg) 1,130 lbs (512.6 kg) Recycled Content (metal): 25% Post Consumer, 6% Pre Consumer Recycled Content (membrane): 0% Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1L5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: All information provided by Sika Corporation ("Sika') concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products, is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice, recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's most current Technical Data Sheet, product label and Material Safety Data Sheet which are available at usa.sarnafil.sika.com or by contacting 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the warnings and instruction for each Sika product as set forth in the current Technical Data Sheet, product label and Material Safety Data Sheet prior to product use. Product Data Sheet Edition: 10/2011 Version no.: 0001 Sarnacorners - Inside Overview: Sarnacorners - Inside are a 60 mil (1.5 mm) thick prefabricated corner used as a time -saving and attractive part of a wall flashing detail. Sarnacorners - Inside come in EnergySmart white. Composition: Sarnacorners - Inside are injection molded with the same time -proven for- mulation used in our Sarnafil membranes. Features: Sarnacorners - Inside simplify the flashing procedures for inside corner details reducing the risk of leakage. They are available in one size which accomodates most inside corners. Sarnacorners - Inside are heat -welded in place, becoming an integral part of the flashing assembly. Packaging: Sarnacorners - Inside are packaged in boxes of 10 pieces. Each box weighs a total of 30 lbs (13.6 kg). Installation: After the wall flashings are installed, Sarnacorners - Inside are heat welded in place with a hand-held hot-air welder and roller. No caulking or sealants are necessary. Availability: Sarnacorners - Inside are available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roofing or Waterproofing System. Warranty: As a Sika Sarnafil supplied accessory, Sarnacorners - Inside are included in Sika Sarnafil's Standard or System Warranty. Sarnafil® Maintenance: Sarnacorners - Inside require no maintenance. Periodic maintenance of a Sika Sarnafil system ensures extended performance and reduces life cycle costs. Consistent with industry practices, Sika Sarnafil recommends in- specting the roof system for damage, plugged drains, weathered sealants, etc. at least twice a year and after each storm. Technical: Sika Sarnafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: The information, and. in particular, the recommendation relating to the application and end-use of Sika Sarnafil products, are given in good faith based on Sika Sarnafil's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika Sarnafil recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no war- ranty in respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Sarnafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Product Data Sheet Edition: 10/2011 Version no.: 0001 Sarnacorners - Outside Overview: Sarnacorners - Outside are a 60 mil (1.5 mm) thick prefabricated corner used as a time -saving and attractive part of curb and wall flashing details. Sarnacorners - Outside are available in EnergySmart white. Composition: Sarnacorners — Outside are injection molded with the same time -proven formulation used in Sarnafil membranes. Features: Sarnacorners — Outside simplify the flashing procedures for various penetrations, reducing the risk of leakage at outside corner details. They are available in one size which will accommodate most outside corners. Sarnacorners - Outside are heat -welded in place, becoming an integral part of the flashing assembly. Packaging: Each carton contains 20 outside corners. Each box weighs a total of 30 lbs (13.6 kg). Installation: After the curb or wall flashings are installed, Sarnacorners - Outside -are heat welded in place with a hand-held hot-air welder and roller. No caulking or sealants are necessary. Availability: Sarnacorners - Outside are available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roofing or Waterproofing System. Warranty: As a Sika Sarnafil supplied accessory, Sarnacorners - Outside are included in Sika Sarnafil's Standard or System Warranty. Sarnafil® Maintenance: Sarnacorners - Outside require no maintenance. Periodic maintenance of a Sika Sarnafil system ensures extended performance and reduces life cycle costs. Consistent with industry practices, Sika Sarnafil recommends inspecting the roof system for damage, plugged drains, weathered seal- ants, etc. at least twice a year and after each storm. Technical: Sika Sarnafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: The information, and, in particular, the recommendation relating to the application and end-use of Sika Sarnafil products, are given in good faith based on Sika Sarnafil's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika Sarnafil recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no war- ranty in respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Sarnafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. Product Data Sheet Edition: 04/2013 Version no.: 0002 Sarnastack Universal Overview: Sarnastack Universal is a 60 mil (1.5 mm) thick prefabricated stack/pipe boot used as a time -saving and attractiv rant of a Sika Sarn fil roofing system. Sarnastack Universal comes injEnergySmart White, Tan and Light Gray. Composition: Sarnastack Universal is injection molded with the same time -proven formu- lation used in our Sarnafil membranes. Features: Sarnastack Universal simplifes the flashing procedures for stack/pipe details reducing the risk of leakage. They are available in one size which accomodates stack/pipe penetrations from 3/4" - 8" (19mm-203mm) in diameter. Sarnastack Universal is heat -welded in place, becoming an inte- gral part of the Sika Sarnafil roofing system. Packaging: Sarnastack Universal is packaged in boxes of 8 pieces and comes with custom made stainless steel clamps. Each box weighs a total of 30 lbs (13.6 kg). Installation: Sarnastack Universal's lower flange is heat welded in place with a hand- held hot-air welder and roller. The top is then clamped to the stack/pipe using the clamp provided. Sikaflex la is then used to caulk around the top. Availability: Sarnastack Universal is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roofing or Waterproofing System. Warranty: As a Sika Sarnafil supplied accessory, Sarnastack Universal is included in Sika Sarnafil's Standard or System Warranty. Sarnafil® Maintenance: Sarnastack Universal requires no maintenance. Periodic maintenance of a Sika Sarnafil system ensures extended performance and reduces life cycle costs. Consistent with industry practices, Sika Sarnafil recommends in- specting the roof system for damage, plugged drains, weathered sealants, etc. at least twice a year and after each storm. Sika Sarnafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: usa.sarnafil.sika.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6915 Davand Drive Mississauga, ON L5T 1L5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: can.sika.com Disclaimer: All information provided by Sika Corporation ("Sika') concerning Sika products, including but not limited to, any recommendations and advice relating to the application and use of Sika products. is given in good faith based on Sika's current experience and knowledge of its products when properly stored, handled and applied under normal conditions in accordance with Sika's instructions. In practice, the differences in materials, substrates, storage and handling conditions, actual site conditions and other factors outside of Sika's control are such that Sika assumes no liability for the provision of such information, advice, recommendations or instructions related to its products, nor shall any legal relationship be created by or arise from the provision of such information, advice. recommendations or instructions related to its products. The user of the Sika product(s) must test the product(s) for suitability for the intended application and purpose before proceeding with the full application of the product(s). Sika reserves the right to change the properties of its products without notice. All sales of Sika product(s) are subject to its current terms and conditions of sale which are available at usa.sarnafil.sika.com or by calling 800-451-2504. Prior to each use of any Sika product, the user must always read and follow the warnings and instructions on the product's most current Technical Data Sheet, product label and Material Safety Data Sheet which are available at usa.sarnafil.sika.com or by contacting 800-451-2504. Nothing contained in any Sika materials relieves the user of the obligation to read and follow the wamings and instruction for each Sika product as set forth in the current Technical Data Sheet. product label and Material Safety Data Sheet prior to product use. Product Data Sheet Edition: 5/2009 Version no.: 0005 Aluminium Tape As Needed Overview: Aluminum Tape is used as a separation barrier between contaminated materi- als and Sarnafil membrane. Composition: Aluminum Tape is a 25/50 rated aluminum foil tape with a pressure sensi- tive adhesive applied to one side for bonding to substrates. The adhesive is covered with a paper liner. Features: Aluminum Tape conforms to irregular surfaces. The paper liner removes easily to expose the pressure sensitive adhesive. Packaging: Aluminum Tape is available in lengths of 150 ft (45.7 m) by 2 in (51 mm) wide and comes in rolls of 24 per case. Installation: Aluminum Tape is to be applied to a clean, prepared surface. The surface preparation may include but is not limited to scraping and wiping the surface free of any excessive contaminates. Once the surface has been prepared apply the Aluminum Tape to the prepared surface making sure all contaminated areas are covered completely with the Aluminum Tape. Once the Aluminum Tape is applied, make sure it is securely in place and does not allow any contaminates to be exposed to the contact area of the Sarnafil membrane. Availability: Aluminum Tape is available directly from Sika Sarnafil Authorized Applicators when used within a Sika Sarnafil Roofing or Waterproofing System. Contact Sika Sarnafil or visit our website www.sikacorp.com for further information. Warranty: As a Sika Sarnafil-supplied accessory, Aluminum Tape is included in Sika Sarnafil's Standard or System Warranty. Sarnafil® Maintenance: Aluminum Tape requires no maintenance. Technical: Sika Sarnafil provides technical support. Technical staff is available to advise applicators as to the proper installation method. Technical Data: Adhesion to Backing Adhesion to Steel Adhesive Backing Elongation Tensile Break Temperature Range 36 oz./in width (39 N/100 mm) 75 oz./in width (81 N/100 mm) Rubber 2 mil dead soft aluminum foil 11% 23 lbs/in width (403 N/100 mm) -20°F (-29°C) thru +150°F (66°C) Corporate Office Sika Sarnafil A Division of Sika Corporation 100 Dan Road Canton, MA 02021 Tel.: (781) 828-5400 1-800-451-2504 Fax: (781) 828-5365 Web: www.sikacorp.com Email: webmaster.sarnafil@us.sika.com Canada Office Sika Sarnafil A Business Unit of Sika Canada 6820 Davand Drive Mississauga, ON L5T 1J5 Tel.: (905) 670-2222 1-800-268-0479 Fax: (905) 670-5278 Web: www.sika.ca Disclaimer: The information, and, in particular, the recommendation relating to the application and end-use of Sika Sarnafil products, are given in good faith based on Sika Sarnafil's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika Sarnafil recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no war- ranty in respect of merchantability of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, may be inferred from this information. The user of the product must determine the product's suitability for the intended application and purpose. Sika Sarnafil reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned. copies of which will be supplied on request. Quasar Prismatic Industrial Skylight w/Thermal Barrier Break and (Optional) Security Grill Prismatic Triarch Model ALB Frame Material Aluminum Details (Scale: 3":1'-0") c Polyvinyl Chloride (PVC) thermal barrier break (ULIFM Code Compliant) ALB -SF -2 ALB -CMT -2 Specifications Quasar Skylight shall be model No. as manufactured by Bristolite Daylighting Systems, Santa Ana, CA. The skylight shall be fully factory assembled consisting of a plastic dome using prismatic material with a CC -2 classification that is sealed by interior and exterior gaskets to a 6063-T5 heliarc welded aluminum frame fabricated of aluminum with a polyvinyl chloride (PVC) thermal barrier break (UL/FM Code Compliant) to prevent thermal losses through the frame and the formation of condensation on its interior surfaces. The frame is to have an integral condensation channel. The aluminum retaining cap fasteners are to be corrosive resistant. The base frame shall be installed either on a 1-1/2" wide curb furnished by others or on its own 4", 9", or 12" high self flashing curb fabricated from aluminum with a 2-3/4" roof flange. Sizes: Model Inside Curb Model Number Dimension Number L 1414 -ALB 1414" x 141/4" r 6060 -ALB 1919 -ALB 19" x 19" L 2222 -ALB 221/4" x2214" 12272 -ALB 3030 -ALB 301/4" x 301/4" 2296 -ALB 3737 -ALB 37" x 37" `2448 -ALB 4242 -ALB 42" x 42" 2496 -ALB 4646 -ALB 461/4" x 461/4" 1 3037 -ALB 4848 -ALB 48" x 48" 5555 -ALB Inside Curb Dimension 60" x 60" Model Number 3096 -ALB Inside Curb Model Inside Curb Dimension Number Dimension 301/4" x 96" L 4872 -ALB 48" x 77 3496 -ALB 34" x 96" 4884 -ALB 48" x 84" 221/4" x 72° 43696 -ALB 36"x96" L4896 -ALB 48"x96" 221/4" x 96" 36120 -ALB 36" x 120" 48120 -ALB 48" x 120" 241/4"x48" _ 3746 -ALB 37° x 4614" 15460 -ALB 54"x60" 241/4" x 96" 3775 -ALB 37" x 75" 6072 -ALB 60" x 72" 3014" x 37° [ 3859 -ALB 38" x 59" ! 6084 -ALB 60"x84" 3046 -ALB 301/4" x 4614" 4669 -ALB 4614" x 691/2" 6096 -ALB 60" x 96" 55" x 55" r 3069 -ALB 301/4" x 691/2" L4689 -ALB 461/4" x 891/2" L60120 -ALB 60" x 120" Solar Heat Gain Coefficient = .50, U Factor = .57, Visible Light Transmission = 70% (Typical for WPM double glazed units) Features: 1. Curb Mounted (CM) or Self Flashing (SF) 2. Two Prismatic Color Choices: White Prismatic Acrylic (WPM) or Clear Prismatic Acrylic (CPM) Add highlighted suffixes to model number where applicable: i.e. 3030 -ALB -SF -2 -CPM -WPM -9 -WP Options: 1. Insulating Double Domes (2) or Single Dome (1) 2. Pyramid (P) or Double Hp (DH) Shaped Dome (selected sizes) 3. Low Profile Dome (LP) (selected sizes) 4. Frame Finish - Bronze Anodize (BA), Clear Anodize (CA), White Painted (WP) or Mill Finish (MF) 5. Self Flashing Bases of 9" or 12" (9 or 12) Options: (cont.) 6. Insulated Frame (INS) 7. Double Wall Frame (DW) Accessories: See PDS (Product Data Sheets) for these Items 1. Gladiator a. Structural Curb (SC) b. Security Grills (SG) c. Safety Screens (SSCRN) 2. Quickkit (Installation Kits) a. Stainless Steel (QKSS) b. Zinc Plated (QKZP) Bristolitd Daylighting Systems sim;s,uilight for enc:tysaving, 401 E. Goetz Avenue Santa Ana, CA 92707 sales@bristolite.com www.bristolite.com 800.854.8618 714.540.8950 Fax 714.540.5415 PDS-1414-AL-QSR Gistilalof ,rcreen Galvanized Steel Wire Mesh Safety Screen Model SSCRN Material Galvanized Steel Bristolite safety screen has been load tested and complies with OSHA — CFR's for fall protection. Details (Scale: 1/2":1'-0") (0 TOP VIEW OF CLIP SIDE VIEW OF CLIP Org e- a ti Specifications Gladiator Safety Screens shall be model No. as manufactured by Bristolite Daylighting Systems, Santa Ana, CA. Safety screens shall be fully factory assembled consisting of a 0.156" galvanized steel wire mesh, corrosion resistant metal connecting clips and fasteners for wood or metal curbs. The safety screen is to be attached to the skylight curb using corrosion resistant fasteners with an interval spacing of no more than 12" centers. For wood curbs utilize 11/2" x #10 tapping Philips head wood screws. For metal curbs utilize #10 Philips head metal screws, length of which are dependent on curb material. Sizes: Model Inside Curb Model Inside Curb Model Inside Curb Model Inside Curb Number Dimension* Number Dimension* Number Dimension* Number Dimension* L 1414-SSCRN 141/4" x 141/4" L6060SSCRN 60'x60" L2272-SSCRN 221/4" x 72" ( 3775-SSCRN 37" x 75" 1919-SSCRN 19" x 19" 7070-SSCRN 701/4" x 701/4" 2296-SSCRN 221/4" x 96" 3859-SSCRN 38" x 59" [ 2222-SSCRN 221/4" x 221/4" L7575-SSCRN 75" x 75" ( 3037-SSCRN 301/4" x 37" j 4669-SSCRN 461/4" x 691/2" 3030-SSCRN 301/4" x 301/4" 8484-SSCRN _ 84" x 84" 3046-SSCRN 301/4" x 461/4" 4689-SSCRN 461/4" x 891/2" [ 3737-SSCRN 37' x 37" - r 9292-SSCRN 921/2" x 921/2" 3069-SSCRN 301/4" x 691/2" [ 4896-SSCRN 48" x 96" 4242-SSCRN 42" x 42" 3096-SSCRN 301/4" x 96" 48120-SSCRN 48" x 120" [ 4646-SSCRN 461/4" x 461/4" L 2230-SSCRN 221/4" x 301/4" r 3496-SSCRN 34" x 96" [ 5460-SSCRN 54' x 60" 4848-SSCRN 48" x 48" 2237-SSCRN 221/4" x 37" 36120-SSCRN 36" x 120" 6072-SSCRN 60" x 72" [ 5555-SSCRN 55° x 55" [ 2246-SSCRN 221/4" x 461/4" [ 3746-SSCRN 37" x 461/4" 1 6096-SSCRN 60' x 96' *The outside of screen dimension is 0.5" smaller than the desired skylight inside curb dimension. Features: 1. Corrosion Resistant Metal Connecting Clips 2. 0.156" Galvanized Steel Wire Mesh 3. 4.0" x 4.0" Grid Opening 4. Fasteners for either Wood Curbs (WD) or Metal Curbs (MTL) Example model number where applicable: i.e. 4848-SSCRN-WD or 4848-SSCRN-MTL Bristolite Daylighting Systems harnessing sunlight for energy savings 401 E. Goetz Avenue Santa Ana, CA 92707 sales@bristolite.com www.bristolite.com 800.854.8618 714.540.8950 Fax 714.540.5415 PDS-2500-SSCRN [aYnevs Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.wavnesroofin q.com WAW.I 'ti NOUHVG, 1%(.. 111 ill' SUMMER. WA CERTIFICATIONS 3 World Class Roofing and Waterproofing October 3, 2013 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 Re: Approved Applicator Project: 17500 West Valley Highway Building Tukwila, WA To Whom It May Concern: This letter is to certify that Wayne's Roofing, Inc. has been an approved and qualified Sika Sarnafil roofing applicator in good standing since 1991 and qualifies for available Sika Sarnafil roofing warranties. Wayne's Roofing, Inc. has earned the status of Elite Applicator, our highest overall rating relative to quality installations, technical expertise, payment history and integrity. If you have any questions, please contact our office. Regards, Sika Sarnafil Jesse Quezada Western Area Director Sika Sarnafil, A Division of Sika Corporation • 10701 Holder Street, Cypress, CA 90630 Tel. 800-421-1662 • Fax: 714-821-9356 • www.sikacorp.com Sarnafil® . TGFU.R8992 - Roofing Systems Page 1 of 25 ONLINE CERTIFICATIONS DIRECTORY Paoe Bottom TGFU.R8992 Roofing Systems Roofing Systems See General Information for Roofing Systems SIKA SARNAFIL INC CANTON COMMERCE CENTER 100 DAN RD CANTON, MA 02021 USA R8992 References to "Sikacoat" include "Sikacoat FC3500", "Sikacoat FC35000", "Sikacoat FC3500T", "Sikacoat FC3400", "Sikacoat FC3400Q", "Sikacoat FC3300", "Sikacoat FC3600", "Sikacoat VR", "Sikacoat BC1000", "Sikacoat BC1000Q". Reference to "Sarnatherm m" include "Tapered Sarnatherm m" or "Sarnatherm m 25 psi" "Sarnatherm m Cover Board" may be placed over the "Sarnatherm m" in any of the following classifications Reference to "Sarnatherm r" include "Sarnatherm r Tapered". Reference to "Sarnatherm r Ultra" include "Sarnatherm r Ultra Tapered". "Sarnatherm-A Roof Board" may be used over any "Sarnatherm" polyisocyanurate insulation product in any of the following Classifications. "Textured G410-12", "Textured G410-14", "Textured G410-14/Felt", "Textured G410-15", "Textured G410-18" and "Textured G410-20" are acceptable alternates to "G410-12", " "G410-14", "G410-14/Felt", G410-15", "G410-18" and "G410-20" respectively. One-half in. thick (min) gypsum board or 1/4 in. thick (min) G -P Gypsum DensDeck® may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 in. min) roof decks. The joints in the gypsum board and overlayment board are offset 6 in. with the joints in the deck. 1/2 in. thick (min) gypsum board or 1/4 in. thick (min) G -P Gypsum DensDeck® may be used in any existing noncombustible deck Classification. When this is done, the resulting roofing system is acceptable for use over combustible (15/32 in. min) roof decks. The joints in the gypsum board or overlayment board are offset 6 in. with the joints in the deck. If polystyrene insulation is used in the existing noncombustible deck Classification, it must be placed beneath the gypsum board or DensDeck®. Any system listed for use over a combustible deck can be installed over a non-combustible deck and achieve the same classification. Uniform thickness or tapered insulation may be used in the following systems provided they do not exceed the indicated incline or thickness. Unless otherwise indicated, on non-combustible decks, Sika Sarnafil Inc. "Sarnatherm Roofboard H" or "Sarnatherm Composite Roofboard H", or Hunter Panels "H -Shield HD" or "H -Shield HD Composite" may replace, or be used in addition to, any Sika Sarnafil Inc. Sarnatherm product or Hunter Panels H - Shield product or any UL Classified wood fiberboard, in any UL Classified insulated roofing system assembly and retain the classification of that assembly, though the max slope cannot exceed 1/2:12 if Sika Sarnafil Inc. "Sarnatherm Roofboard H" or "Sarnatherm Composite Roofboard H", or Hunter Panels "H - Shield HD" or "H -Shield HD Composite" is used directly below TPO membrane. Unless otherwise indicated, on combustible decks, Sika Sarnafil Inc. "Sarnatherm Roofboard H" or "Sarnatherm Composite Roofboard H", or Hunter Panels "H -Shield HD" or "H -Shield HD Composite", may be used in addition to any Sika Sarnafil Inc. Sarnatherm or Hunter Panels H -Shield product or any UL Classified wood fiber board, in any insulated UL Classified roofing system assembly and retain the classification of that assembly, though the max slope cannot exceed 1/2:12 if Sika Sarnafil Inc. "Sarnatherm Roofboard H" or "Sarnatherm Composite Roofboard H", or Hunter Panels "H -Shield HD"or "H -Shield HD Composite" is used directly below TPO membrane. Sika Sarnafil Inc. "Sarnatherm Roofboard H" or "Sarnatherm Composite Roofboard H", or Hunter Panels "H -Shield HD" or "H -Shield HD Composite"" may be used over any UL Classified polystyrene on non-combustible decks. Max incline shall be in accordance with the Classification established for the insulation/membrane roofing system, but cannot exceed 2:12. "Sarnacol 2170R" is an acceptable alternate to "Sarnol 2170". For Combustible Decks - Class A: 1. A minimum 3 in. layer or a minimum two layers of 1.5 in. of Sika Sarnafil Inc, "Sarnatherm Composite Roofboard H" or Hunter Panels, "H -Shield HD Composite" is placed directly over a combustible deck and is covered with any UL Classified roofing membrane used in any UL Class A roofing assembly to achieve a Class A fire Classification. As an alternative, any UL Classified insulation (except expanded or extruded polystyrene), any combination, any thickness, may be used below the 3 in. minimum total thickness of Sika Sarnafil Inc. "Sarnatherm Composite Roofboard H" or Hunter Panels "H -Shield HD Composite". The insulation may be loosely laid or attached with fasteners and plates, hot roofing asphalt or cold adhesive. A vapor barrier (non -UL classified) may also be used below the insulation. All insulation joints must be staggered a minimum of 6 in. from the deck joints or from the insulation joints directly below. The maximum incline shall be in accordance with the Classification established for the membrane/insulation roofing assembly, however the incline cannot exceed 1/2:12. http://database.ul.com/cgi-bin/XYV/template/L1SEXT/1 FRAME/showpage.html?name=TG... 4/5/2013 TGFU.R8992 - Roofing Systems 1. Deck: NC Incline: 3/4 Page 3 of 25 Existing Roof System: — Class A, B or C (gravel may be removed) to retain the existing Classification covered with: Insulation: — "Sarnatherm I" (tapered or uniform thickness), mechanically fastened. Membrane: — "G410", "G410/Felt", "G410-14", "G410-14/Felt", "G410-15", "G410-15/Felt", "G410-18 ", "G410-18/Felt", "G410-20", "G410- 20/Felt" or "G410-24" (PVC), secured with "Sarnacol 2170" or "Sarnacol 2170 VC" adhesive at 1-1/2 gal/sq., "S327" mechanically fastened. 2. Deleted. 3. Deck: C-15/32 Incline: 2 Existing Roof System: — Insulated or noninsulated cap sheet, Class A, B or C system to retain the existing Classification is covered with: Insulation (Optional): — One of the following, any thickness: a. Perlite b. Fiberboard c. Rmax Multi -Max FA -3 or "Thermaroof Plus" d. Firestone "Iso 95+GL", "Iso 95+GW" e. Apache Products "Apache Pyrox", "Apache White Line" or "Apache Tapered Pyrox" f. Johns Manville "ENRGY 3" g. "Sarnatherm I" or "Sarnatherm II" h. Atlas Roofing "ACFoam II" i. "Sarnatherm a" j. "Sarnatherm Perlite Composite", "Tapered Sarnatherm Perlite Composite", "Sarnatherm Woodfiber Composite", "Tapered Sarnatherm Woodfiber Composite" or "Sarnatherm Nailboard" k."Sarnatherm m" I. "Sarnatherm r" Membrane: — "G410", "G410/Felt", "G410-14", "G410-14/Felt", "G410-15", "G410-18", "G410-18/Felt", "G410-20", "G410-20/Felt", "G410-24", "S327", "5327/Felt", "5327-14", "5327-14/Felt", "5327-15", "5327-18", "5327-18/Felt", "5327-20", "5327-20/Felt", "S327-24" (PVC). 4. Deck: C-15/32 Incline: 2 Existing Roof System: — Insulated or noninsulated cap sheet, Class A, B or C System to retain the existing Classification is covered with: Insulation (Optional): — One of the following, any thickness: a. Perlite b. Fiberboard c. Rmax Multi -Max FA -3 or "Thermaroof Plus" d. Firestone "Iso 95+GL", "Iso 95+GW" e. Apache Products "Apache Pyrox", "Apache White Line" or "Apache Tapered Pyrox" f. Johns Manville "ENRGY 3" 9. "Sarnatherm I"or "Sarnatherm II" h. Atlas Roofing "ACFoam II" "Sarnatherm a" j. "Sarnatherm Perlite Composite", "Tapered Sarnatherm Perlite Composite", "Sarnatherm Woodfiber Composite", "Tapered Sarnatherm Woodfiber Composite" or "Sarnatherm Nailboard" k. "Sarnatherm m" I. "Sarnatherm r" http://database.ul.com/cgi-bin/XYV/template/LISEXT/1 FRAME/showpage.html?name=TG... 4/5/2013 Wayne's Roofing, Inc. 13105 Houston Road Sumner, WA 98390 www.waynesroofing.com %%MAI 'ti HOOF i' (., N(.. i`s" i : l { : JO, SUMNER. WA WARRANTIES 4 Sarnafil® 100 Dan Road • Canton, MA 02021 (781) 825-5400 • Fax: (781) 828-5365 Warranty Serial No.: SAMPLE 20 ear System Warranty SIKA SARNAFIL ROOFING WARRANTY F Building Owner. SAMPLE Building Name: SAMPLE Building Address: SAMPLE Date of Substantial Completion: SAMPLE Date of Inspection: SAMPLE Contractor. SAMPLE Sika Samafil Inc. ("Sika Sarnafil"), warrants to the owner o . limitations stated herein, Sika Samafil will repair teaks originating Roofing Accessories installed according to S - amafi s 20 (twenty) years commencing with the dat of substantial comple OMMERCI ' r UILDING buUding describe the Samafil R •nsbya ation of the Roo • cal ins TERMS, CONDITIONS, LIMITATIO 1. Owner shall notify Sika Samafil on in writing within one week. 2. If on Sika Samafil's inspection. SI Insulation or Accessory provided Applicator's workmanship appli = . Sika Samafil's liability shall be 3. This warranty does not apply (a) The Roofing Membrane windstorm in excess of •� The Roofing Membrane orA falling objects. civil disobedience, • - f A deficient pre-existi = , ndition or e There are any alters structures are plac: Failure by the Own warranty, includin A significant change I f originally installed, or: Loss of integrity of the building e siding, windows. doors or other envelop Should buildi : - a freezer or cooler, c the vapor b' - • ess. or: (i) The Owner 4. During the peri• 5. Should the Roo and/or repair, such a 6. Slka Samafil shall have n I 7. Sika Samafil's failure at any ti t f provision. 8. This warranty is given in lieu of all othe es stated herein ar I (b) (c) (d) (e) (f) (9) (h) • I d rAccessory i d mph, hurricane, or toma Ac soryisda sed byanyac ct of wa -,• q ' ent is ' '} - • water entry, ons or . ' . rs made on : hrough t • leted roof. or • on or attache • - : - d roof w t obtaining r or his lessee to use rea - - in mainta • : oof as d hat of sealants and caulking, o . use o the bw • <.,` the Owner o �c see expe 1 c first business d as: SAMP Area By: SAMPL Telephone: SAMPL • •r_ nted: SAMPLEsq. ft. ove ("Owner"), that subjec o • : , embrane, Samath SliceSam..uthorized f the following th - covery of e math determines he leak . caused by a by S ' . : mafil to the App - • r or this building at Sama = mbrane, except a provided in the f ted - .a Same i . .air of the Roofing Membra may be nu the following occur s am - • . disaster includin void If a •b • em 0 rm Insula fing Applicator rane. erms, • it Sik • s, and Sarnafil period of ak In the Roofing Syste and confirm fect in Samafirs Ro • • Membra e, Samatherm r from a defect in the afil Authorized • Rowing paragraph three (3) Own - I's remedies and e, Sarnatherm Insulation or Accessory, t not limited to, earthquake, lightning, hail, • a na r• • egligence, 'dent, or misuse in . • ng, but not limited to, vandalism, e com le by such a = not limited o fixtures, equipment, or authoriz ' •• • Sika Samafil, or. 86 s Guide provided with this • the Own rn Saafil to e e and, or s �?n - ' • Iuding. but not limited t• - • ponents or • • r• • • - mage by wind blown onden ' • accumulate e • • sembly due purpose. cons kind cont - 9. This exten costs 10. Any • rier e e ails to comply wi d of this warranty, Sika Sar embrane be concealed, moval and i- cement of any paving ligation un. - . rranty until all invoices o enforce . o : ms or conditions state term and condition n : • ents and employ - the cos •osure of the s -• • herein. shall have fre Mem urden, e ential or inciden atsoever, including, but nts thereof, or to any oth arranty Is ext - •Ie nor is it oth to rocess the contr rsy or claim • • • • . - •, se assig nsfer an •- the Roofing Membrane as rtial or •• • ete loss of roof decking, wall . 'acts, or: to inc • ct design or due to a reduction in ess to brane the Owner' lation, sh- teriais, i • n sha rranties, ex s or i plied, Including any warranty of elusive re - • s and Sika Sarn shall not resence of molds, fungi, ba the building on which ages including • - ot limited to, dame - property or persons. and exclu L - , to the Ovine abl = ansfera • e other • • • o inspect and repair the out of or relating to this Warranty s Arbitration As • ciation in accordance with the Construction Industry A entered in any co • - aving jurisdiction thereof. the Building unless app ry, are dby arbitr- les, a • ne na, • - he componen oof during regular business hours. rposes of Sika Samafil's investigation Owner's sponsibility. nd services have been paid for in full be construed to be a waiver of such erchantability or fitness for a particular responsible or liable for any Indirect otoxins or the like or further loss of any of the roof are situated, damage to the e time the Roofing Membrane is installed. It does not ro In advance and in writing by Sika Samafil and the paid •y the original owner. on in Boston, Massachusetts by the American d judgment upon the arbitration award may be be NO REPRESENTATIVE OF SI Issued By: SAMPLE Authorized Signature: Title: SAMPLE AFIL HAS AU SAMPLE Date: • RITY TO MAKE SAMPLE • tion Y REPRESE ATIONS OR PROMISES EXCEPT AS STATED HEREIN. This Warren y is effective from: SAMPLE Through: SAMPLE i \...,____ ■ Roofing Guarantee,oX00X Whereas WAYNE'S ROOFING, INCORPORATED, of Sumner, ashi gton, herein called "the Contractor," has completed application of the following roof \ Owner: SAMPLE WARRANTY ■ Address of Owner: N Type and Name of Building: NN NN Location N Area of Roof ' Date of Completion: N. Date Guarantee Expires: N \,N > at the inception of such work the Contracto -agree to gua tee th a oresaid rdof ag int faulty Whereas,/ materials or workmanship for a limited period and subject to the c editions herein set forth: / Now, Therefore, the Contractor hereby G ran es, subje to the conditions rein set forth, that during a period of Two_(_2_J year from the date of completion fsaid/roof it will, a its own cost and exppens\e, make or cause to be made such repairs to said roof and composition flashin resulting solely iron faults or defects in materials or workmanship applied by or through the Contractor as may be necessg to maintain said roo in w tertight condition. This guarantee is made subject to the following condit as: 1. Specifically excluded from this guarantee is any an l dam to s d roo , the building or contents caused by the acts or omissions of other trades or contractors; li htning, wt d orm, storm, or other unusual; phenomena of the elements; foundation settlement; failure or cracking f the roof deck; or failure of material used as a roof base over which the roof is applied, faulty construction of arapet wal copings, ys,Nskylights, vents, supports, or other parts of the building; vapor condensation beneath the of; pene ns for pitc kxes; or fire. If the roof is damaged by reason of any of the foregoing this guarantee shall there . to be me nut and void orthe balance of the guarantee period unless such damage is repaired by the Contractor at the e . -•, sego party requesting sut i emirs. 2. The Contractor is not liable for consequential 4 to e building or contents resulting from any defects in said roof or composition flashing. 3. No work shall be done on said roof, including, b tovithout limit 'on wor)( in connection with flues, vents, drains, sign braces, railing, platforms tidier equipment fastened`to or'set on the of, d no repairs or alterations shall be made to said roof, unless the Contra or shall be first- notified, shall\ke gi%en the opportunity to make the necessary roofing application recommendations wit respect thereto, and such teeommendations are complied with. Failure to observe this condition shall render this guarantee nni and ikti.Conttaite shall\ be paid for time and material expended in making recommendations or repairs o toned by,the work-o0,thers on said roof. 4. This guarantee shall become null d void if the roof is used-as,a promenade or work deck or is sprayed or flooded, unless such use was originally specified an a specification is noted in paragraph 8 below. Areas that pond water shall not be covered bypthis guarantee. 5. This guarantee shall -lot be or become effe 've unless and until the Contractor has been paid in full for said roof in accordance with the weenie* pursuant to which eh r9of was applied. 6. This gua antee sha come null android-unles_the-Contractor is promptly notified of the alleged defect in materials or workmans'h p and pppofitnity to inspec't%the roof. 7. This guaraniis in\lieu of alyother/gilarantwarranties, express or implied 8. Additional co citionS.or �xdusiops : In Witness Whereof, i is insstrtimen has been duly executed this day of , 200X WAYNE'S ROOFING, INC. 13105 HOUSTON ROAD SUMNER, WASHP GTON 98390, 'GAC. (253) 863-4455 ,SEA (206);575.0078 ' i BY AUTHORIZED REPRESENTATIVE Donald Guthrie, President PEW COORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-317 PROJECT NAME: TUFF SHED - REROOF SITE ADDRESS: 17500 WEST VALLEY HY X Original Plan Submittal Response to Correction Letter # DATE: 10-10-13 Response to Incomplete Letter # Revision # After Permit Issued EPARTMENTS: 4d4Ofl Iit Public Works Aw1114/1 NSA I0—ISS` Fire Prevention / Planning Division Structural Permit Coordinator a DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-15-13 Complete 5t) Incomplete Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Not Approved (attach comments) n Notation: 7 REVIEWER'S INITIALS: DATE: DUE DATE: 11-12-13 Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 • • PLAN REVIEW CHECKLIST - (Nonstructural) Permit App. 0 1? -37 % By: IBC Edition 12-- & State Amend. Date: /0 -/r—d- Project title: /m-?6,Zte +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ X". Classify the building or portion thereof in accordance with Chapter 3 etermine the type of construction of the building in accordance with Chapter 6. J�^Determine if the location of building on the site and clearances to property lines and other buildings on the site plan are in accordance with code provisions. Review for conformity with General building height and area limitations in accordance with Chapter 5. Review for conformity with special detailed requirements based on use and Occupancy. Review for conformity with Type of Construction requirements of Chapter 6. Review for conformity with Fire and Smoke protection features of Chapter 7. Review for conformity with requirements of interior finishes of Chapter 8. Review for conformity with requirements for fire protection systems of Chapter 9. �/- Review for conformity with requirements for means of egress requirements of Chapter 10 Review for conformity with requirements of accessibility in accordance with Chapter 11, and ICC A117.1 eview for conformity with Washington State Energy Code. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ V In circle = topic has been reviewed for the application. X In circle = topic is not relevant to proposed scope of work. Contractors or Tradespeople Peer Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name WAYNE'S ROOFING INC UBI No. 600178144 Phone 2538634455 Status Active Address 13105 Houston Rd License No. WAYNESR205Q5 Suite/Apt. License Type Construction Contractor City Sumner Effective Date 11/25/1980 State WA Expiration Date 5/2/2015 Zip 98390 Suspend Date County Pierce Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ssociated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status RAINIEI923QL RAINIER EXCAVATING INC Construction Contractor General Unused 11/13/2008 11/13/2014 Active Business Owner Information Name Role Effective Date Expiration Date GUTHRIE, DONALD D President 01/01/1980 Bond Amount WETHERBEE, KITTY Secretary 01/01/2007 1968027 WETHERBEE, RODNEY ALLEN Vice President 05/01/2000 WETHERBEE, WAYNE W President 01/01/1980 04/30/2007 MANN, SHARON R Secretary 01/01/1980 04/30/2007 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 9 THE HANOVER INS CO 1968027 04/13/2011 Until Cancelled $12,000.0004/11/2011 04/29/2013 8 INS CO OF THE WEST 1329270 07/22/2001 Until Cancelled 04/13/2011 $12,000.0003/20/2002 04/26/2012 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 26 American Guarantee & Liability GLA399116709 05/01/2013 05/01/2014 $1,000,000.00 04/29/2013 25 Zurich American Ins Co GLA399116708 05/01/2012 05/01/2013 $1,000,000.00 04/26/2012 24 AMERICAN ZURICH INS CO GLA399116707 05/01/2010 05/01/2012 $1,000,000.00 04/29/2011 23 AMERICAN ZURICH INSURANCE CO CP0399116704 05/01/2008 05/01/2010 $1,000,000.00 04/24/2009 22 AMERICAN ZURICH INS CO CP0399116703 05/01/2007 05/01/2008 $1,000,000.0004/30/2007 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period httns://fortress.wa. aov/lni/bbin/Print. aspx 10/24/2013