HomeMy WebLinkAboutPermit D13-329 - COSCO FIRE PROTECTION - TENANT IMPROVEMENTCOSCO FIRE PROTECTION 4308 S 131 PL D13-329 City orTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 7349200135 Address: 4308 S 131 PL TUKW Suite No: Project Name: COSCO FIRE PROTECTION DEVELOPMENT PERMIT Permit Number: D13-329 Issue Date: 11/04/2013 Permit Expires On: 05/03/2014 Owner: Name: NORMED SHAW PTN Address: PO BOX 3644 , SEATTLE WA 98124 Contact Person: Name: AL SMITH Address: 4308 S 131 PL , TUKWILA WA 98168 Contractor: Name: COSCO FIRE PROTECTION INC Address: 10910 - 117TH PL NE , KIRKLAND, WA 98033 Contractor License No: COSCOFP 11 ONM Lender: Name: Address: Phone: 425 766-3450 Phone: 425-827-9654 Expiration Date: 01/13/2015 DESCRIPTION OF WORK: INSTALLATION OF STORAGE RACKS Value of Construction: $0.00 Type of Fire Protection: Type of Construction: Electrical Service Provided by: SEATTLE CITY LIGHT Fees Collected: $250.52 International Building Code Edition: 2012 Occupancy per IBC: **continued on next page** doc: IBC -7/10 D13-329 Printed: 11-04-2013 Public Works Activities: Channelization / Striping: N Curb Cut / Access / Sidewalk / CSS: N Fire Loop Hydrant: Flood Control Zone: Hauling: Land Altering: Landscape Irrigation: Moving Oversize Load: Sanitary Side Sewer: 3ewer Main Extension: Storm Drainage: Street Use: Water Main Extension: Water Meter: Permit Center Authorized Signature: I hereby certify that I have read and joverning this work will be complie N N N Number: 0 Start Time: Volumes: Cut 0 c.y. Start Time: Private: Profit: N Private: Phe granting of this permit does not p :onstruction or the performance of work. :o this permit. xamin with, Date: Size (Inches): 0 End Time: Fill 0 c.y. End Time: Public: Non -Profit: N Public: t oLthe5 d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. Signature: ?rint Name: to give authority to violate or cancel the provisions of any other state or local laws regulating m authorized to sign and obtain this development permit and agree to the conditions attached Sm//% Date: IIA-/ ? Phis permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended Dr abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: l: ***BUILDING DEPARTMENT CONDITIONS*** 3: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the 3uilding Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to ;tart of any construction. These documents shall be maintained and made available until final inspection approval is granted. I: When special inspection is required, either the owner or the registered design professional in responsible charge, ;hall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 3: A final report documenting required special inspections and correction of any discrepancies noted in the inspections ;hall be submitted to the Building Official. The final inspection report shall be prepared by the approved special nspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. ioc: IBC -7/10 D13-329 Printed: 11-04-2013 6: All construction shall be done in conform with the approved plans and the requirem of the International Building Code or International Residential , International Mechanical Code, Washingt ate Energy Code. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***FIRE DEPARTMENT CONDITIONS*** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: The total number of fire extinguishers required for an ordinary hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 1,500 sq. ft. of area. The extinguisher(s) should be of the "All Purpose" (2A, 20B:C) dry chemical type. Travel distance to any fire extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 12: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 13: Fire extinguishers shall not be obstructed or obscured from view. In rooms or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of the extinguishers. (IFC 906.6) 14: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 15: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 16: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 17: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 18: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 19: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 20: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 21: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 22: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 23: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IBC -7/10 D13-329 Printed: 11-04-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. T /3- 3? / Project No. /0/17/( 3 /7/P1 Date Application Accepted: Date Application Expires: (For office use only) CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION King Co Assessor's Tax No.: 73 'i9 too 13 S'O Site Address: 4308 South 131st Place Tukwila, WA 98168 Suite Number: Floor: Tenant Name: Cosco Fire Protection New Tenant: INt Yes ..No PROPERTY OWNER Company Name: Cosco Fire 0 e Name: NORMED SHAW PTN City: Tukwila State: WA Zip: 98168 Address: 4310 S 131ST PL 98168 Contr Reg No.: COSCOFP110NM Exp Date: /'/ 03 City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Company Name: Cosco Fire 0 e Name: AL J` n . vim/ City: Tukwila State: WA Zip: 98168 /I Address: ..3V0 5.. ill. pL.ild Contr Reg No.: COSCOFP110NM Exp Date: /'/ 03 City: ,,t� t kWti.A State: W'A Zip:181 W 1 $ Phone4,4 IG Gto 34s 6 Fax: Address: Email: AS M 1111 CDS Cb F1kE. COM Phone: vis -Z'[0 _3'st0 Fax: 3Fs( 3 GENERAL CONTRACTOR INFORMATION Company Name: Cosco Fire 0 e Address: 4 S 131ST PL 98168 City: Tukwila State: WA Zip: 98168 Phone:4g Uo(D3 Ay S 6 Fax: Contr Reg No.: COSCOFP110NM Exp Date: /'/ 03 Tukwila Business License No.: & vs ^ 0100e- H:\Applications\Forms-Applications On Line\20I 1 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh ARCHITECT OF RECORD Name: Address: Company Name: Engineer Name: J c �j�.r-r: k Cj‘va•.•�ti Architect Name: Address: Li t Z we�,�o 4 -o.ek 4 Address: CityG l Nr I r' State: CA ipgi ?by Phone: vis -Z'[0 _3'st0 Fax: 3Fs( 3 City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Name: Address: Company Name:c..GS 4... `�'s, C. Engineer Name: J c �j�.r-r: k Cj‘va•.•�ti Address: Li t Z we�,�o 4 -o.ek 4 2.011 CityG l Nr I r' State: CA ipgi ?by Phone: vis -Z'[0 _3'st0 Fax: 3Fs( 3 Email: urgc.IG l 0 14.Lo.. cam g LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ D) 606 .OrT9 Existing Building Valuation: $ Describe the scope of work (please provide detailed information): ln/51A4[1n14 sraRAGE R,eicCk,f Will there be new rack storage? Yes ❑.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-1I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1s` Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes 0 No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers 0 Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes ❑ No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11 " paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\ApplicationsWorms-Applications On Line\201 I Applications\Permit Application Revised - 8-9-1I.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED A N A Signature: �/1i Print Name: A L r' Day Telephone: Date: /4//#J/3 425 -1C9b 34. 61 Mailing Address: sopa tj)Db p,- R . gb B 96 D VJODUNAL WA 110/7, City 10?2- City State Zip H:\Applications\Forms-Applications On Line \201 I Applications\Permit Application Revised - 8-9-1 I.docx Revised August 2011 bh Page 4 of 4 • City of Tukwila Department of Contnzuftity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: Address: 4308 S 131 PL TUKW Suite No: Applicant: COSCO FIRE PROTECTION RECEIPT Permit Number: D13-329 Status: PENDING Applied Date: 10/17/2013 Issue Date: Receipt No.: R13-02903 Initials: User ID: LAW 1632 Payment Amount: $250.52 Payment Date: 10/17/2013 12:00 PM Balance: $0.00 Payee: COSCO FIRE PROTECTION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 1897 250.52 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237,114 Total: $250.52 149.10 96.92 4.50 Printed: 10-17-2013 INSPECTION RECORD: Retain a copy with permit INSP CTION NO. PERMIT NO; CITY OF TUKWILA BUILDING .DIVISION G' 6300 Southcenter Blvd., #100; Tukwila. WA 98188. - , (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Dia -32-1 Project: CoSFe d Typ of Inspection: tSt , \D, - Al Address: 43 O: 13 ( PL. Date Called:. fff Special Instructions: Wit_. CRequester: Date Wanted:'"a.m. ` �" -- - � 3 . frm Phone No:- Approved per applicable codes. EJ Corrections required prior to approval. . . COMMENTS: F!rM;r L t re Date: %t- -. n REINSPECTION FEE REQUIRED. rior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100: Call to schedule reinspection. 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit b13- PERMIT 13 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: 405 Type of Inspection: A -e e Address:r� Suite #: (Ag $ /57/ fe Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /`."9-3'S Needs Shift Inspection: /S Sprinklers: /a1 Fire Alarm: Hood & Duct: /V* Monitor: Pre -Fire: Permits: ,tom Occupancy'Yype: i Inspector Date: /0 G�� Hrs.: / a $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete November 21, 2013 Masonry Asphalt Roofing FileNo.13-678 Piling Steel Soils Wood City of Tukwila Building Department 6300 Southcenter Blvd. #100 Tukwila, WA 98188 Project: Cosco Fire Rack Address: 4308 S. 131st St. Permit: D13-329 A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION AND (MATER:AL TESTI C 'NATIONALLY ACCEPTED LASDRATORY This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our inspection report is attached. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to City of Tukwila approved plans, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. a\- Kimberle Anderson President CC: Cosco Fire -Al Smith Tel: (425) 881-5812 Fax (425) 881-5441 0 7126 180th Ave. NE P.O. Box 2523 Redmond, WA 98073 Field Report Report #: 059578 sting Laboratory, Inc. 7128 180th Aye, Park 180, 8uite'Ci Phone 425-881.5812 Fax 425»881 ,5441, Client: Cosco Fire 4308 S. 131st St. Tukwila, WA 98168 Contact: Al Smith Protect Number: 13-678 Permit #: D13-329 Project Name: Cosco Fire Rack Address: 4308 S. 131st St. Inspection Performed: Proprietary Anchors Date: 11/21/2013 Time: Temperature: Anchor bolts for pallet racks. Verified installation of Hilti KBT2 anchors 1/2" x 4 1/2" with 3 1/4" embed, torqued to 40 ft./lbs. All placed per plan. Distribution: Distribute Client [J Distribute Contractor ❑ Distribute Engineer Li Distribute Owner [J] Distribute Municipality ❑ Distribute Other Distribute Architect [i Distribute Other Inspector: Trow, Michael Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden } BY G. OHANIAN DATE. 10-11-13 SUBJECT RAdK DEOI(N & EN(WINEERINd do. 412 WEST BROADWAY, SUITE #204 dLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 1 JOB NO. RD -17001 STRUCTURAL CALCULATIONS OF STORAGE RACKS FOR: Mr,orytnte COSCO FIRE 4308 SOUTH 131st STREET TUKWILA, WA 98168 PER IBC 2012 EDITION SECTION 2209 STORAGE RACKS CAPACITY: 1500 # / LEVEL AT TYPE "A" 2000 # / LEVEL AT TYPE "B" CALCS. 1 THRU 6 DRAWINGS: RD -17001 EXPIRES 12-26-13 REVIEWED FOR CODE COMPLIANCE APPROVED OCT 302013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 1 7 2013 PERMIT CENTER DIS -321 BY G. GHANIAN RACK DEOI(N & ENd1INEERINO CO. DATE. 10-11-13 SUBJECT 412 WEBT BROADWAY, BUTTE #204 dLENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 2 JOB NO.. RD -17001 BEAM 0 0 Ix=1.84 Sx =.85 Fy =55 KSI. LOAD PER BEAM + 25% IMPACT LOAD (1.5 Kx.88)+(0.8 Kx.25) = 1.5= 0.8 K 2 BEAMS m= 8 22 = 9 K SR= .27<.85 _ a 384.W xL E _ .16"< 180 = .53" SEISMIC DESIGN V= S os xl xW IBC 2012 (SEC. 2209), RMI SPECS. Rx1.4 ASCE 7-10 (SEC. 15.5.3) SDs =1 (USGS WEB SITE, "SITE CLASS D") 1=1 NO PUBLIC ACCESS R=6 MOM. CONN. R=4 BRACED W=D.L.+ 3 PALLET LOAD TYPE "A" LOAD PER COL. - 3x1.5 K =2.2 K 2 COL. P=.20L+ (2•21(x0.75)=1.9K W=.2DL+ (2.2Kx0.67)= 1.7 K PL L= '20 K ONGIT. V = .30 K TRANS. COLUMN ANALYSIS 3" x ---x t=.070" ,lam Fy=55 KSI Ae=.62 I x=.95 Se=.6 rx=1.2 ry=1.1 COMBINED STRESS RATIO Pex= T2E>Z = 166.0 Qc=1 .8 C2b=1.67 ax=1- SZcP = .98 Pex Cmx=.85 LONGIT. SEISMIC KL=24x1.7 _ rx 1.2 -34 KL40 ry = �-36 Mn=Se.Fy= 35 Qc.P+Qb.Cmx.M = .20<1 P„ M..ax .20K 10K 07K 1.1"K== 1.9.1( 03K 1.9"K -= 2.2"K 2.2"K 2 Fe=( KL)2=220 ry z Fn=Fy(.658 Ac )=5o KSI Pn=Fn .Ae = 31.0 K c = -N/Fy /Fe = 0.50 Ac<1.5 BY G. OHANIAN RACK DESIGN & ENdINEERIN( CO. DATE. 10-11-13 SUBJECT 412 WET BROADWAY, �1UITE #204 LENDALE, CA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 3 JOB NO.. RD -17001 BASE PLATE ANCH. TENSION = 0 ANCHOR SHEAR = .10 K (2)-1/2"0 ANCHORS PER BASE PL., 3 1/4" EMB. SIMPSON STRONG BOLT -2 ESR -3037 SPECIAL INSPECTION IS REQUIRED MOMENT AT BEAM CONNECTION 1.9K 2.2 "K IQ8"x5"x3/8" to BASE PLATE .5x.07x1 x65=2.3 K BEARING CAPACITY OF COL. HOLE 1.9 •K 7/16"0 RIVET A = .1 Fy = 79 KSI Pa = .1 x79x.4 = 3 K Ma = (2.3 Kx4")+(1.1 Kx2") = 11.4 "K 3 PIN CONN. CONN. MEND= .O1 xwI 2= .7 "K M— 2.0"KM— 2.7"K SEISMIC TOTAL OVERTURNING MOT =.30Kx2 x84"x0.66 - 33"K COL. — MR = 1.9 Kx44"= 83 "K .30K NO UPLIFT 1.9K 1.9K 1: 71 x .30 K co N n 44" 2.0 "K { 2.0 K 2.2 'K TOP LEVEL LOADING o W= 0.2DL+0.8LL=1.OK LOAD PER COL. V= .17 K =.17 Kx2 X72" = 24 K MOT COL. MR = 1.0 Kx44" = 42 "K NO UPLIFT BY G. OHANIAN RAdK DEOI N & ENOINEERING1 d0. DATE. 10-11-13 SUBJECT 412 WET BROADWAY, OZJITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 4 JOB NO.. RD -17001 BEAM TYPE "B" Ix =1.84 Sx =.85 Fy =6601. LOAD PER BEAM + 25% IMPACT LOAD (2.0 Kx.88)+(1.0 Kx.25) = 2.0= 1.0K 2 BEAMS M= SZ =12"K S R= .37<.85 0- SxwL° =,21"<=.53" 384.1x .E 180 LOAD PER COL. = 4x2.0 K =4.0 K 2 COL. P=•2DL+ (4.0Kx0.75)=3.2K W=.2DL+ (4.0�,KLx0.67)= 2.9 K K V LONGIT. = 'S1 K TRANS. COLUMN ANALYSIS x- 3„ -- x 1 M t=.070" jI COMBINED STRESS RATIO Pex (KL)Ix = 42.0 ax=1 ncP=.86 Pex Fy=55 Ks' Ae=.62 Ix=.95 Se=.6 rx=1.2 rY=1.1 Oc=1.8 Qb=1.67 Cmx=.85 BASE PLATE ANCH. TENSION = 0 ANCHOR SHEAR = .17 K LONGIT. SEISMIC KL=48x1.7 =68 rx 1.2 KL=4�4f=40 Y Mn=Se.Fy= 35 Qc.P+flb.Cmx.M = .62<1 Pn Mn.ax (2)-1/2"0 ANCHORS PER BASE PL., 3 1/4" EMB. SIMPSON STRONG BOLT -2 ESR -3037 SPECIAL INSPECTION IS REQUIRED .34K Fe=( = KLj263 rx 7.9"K 2 F n=F Y(.658 c )=38 KSI Pri=F .Ae = 24.0 K 3.2K 7.9j 10 01 100 2 2"K 3.9"K 5.1"K 7.9"K Xc= "FY/Fe = 0.93 Xc<1.5 8"x5"x3/8" BASE PLATE BY G. OHANIAN RAdK DEOI(N & EN€ INEERIN(t do. DATE. 10-11-13 SUBJECT 412 WET BROADWAY, QUITE #204 LENDALE, CA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO. 5 JOB NO.. RD -17001 MOMENT AT BEAM CONNECTION .5x.07x 1x65=2.3 K BEARING CAPACITY OF COL. HOLE 5.1 "K 7/16"95 RIVET A = .1 Fy = 79 KSI Pa = .1 x79x.4 = 3 K Ma = (2.3 Kx4")+(1.1 Kx2") = 11.4 "K 3 PIN CONN. CONN. MEND-.O1XWI2= 1.0 "K M- 6.5"K SEISMIC M -_ 7.5"K TOTAL OVERTURNING MpT=.45Kx2 x178"x0.66 =121 "K COL. MR = 3.2 Kx44"= 141"K NO UPLIFT LOAD TO DIAGONAL P=.51Kx2 x54=1,3K COL. 44 Fy =55 KSI Ae=.26 rx =.48 Q=.74 L= 54" Pa= 2.7K CHECK WELDS Pa= (1_ .O1L) L.t.F„ = 3.9 K f2= 2.55 / --D-= 1.5K x2 = 3.0K SIDES .51 3 2 K 3.2K 1F\ 71 I x V `.I .51K .13 44" 6.5"K �I ® ®� 6.5"K 7.9 K TOP LEVEL LOADING 0 W O.2DL+1.OLL=1.2K LOAD PER COL. V= .22 K =.22Kx2 x156"= 67"K MOT COL. MR = 1.2 Kx44" = 53 "K UPLIFT =5443 - 32 K BOTH SIDES TYP. By G. OHANIAN DATE. 10-11-13 SUBJECT RAdK DEOI(N & ENdINEERIN(d d0. 412 WET BROADWAY, filUITE #204 LENDALE, dA. 91204 TEL:(818)240-3810 FAX:(818)240-3813 SHEET NO 6 JOB NO. RD -17001 CHECK SLAB 3200 1000 = 3.2 °' 3.2x 144=460 °" V/ 460=21" 4=2 ) x M= ` 1000x 2 x12=844 "# S= 12x62 = 72 6 844 = 12 <1.6 \/2500 =80 72 3200 # 6" CONCRETE SLAB 2500 PSI. CONC. 1000 PSF. SOIL Uw�gu iwap� awnminy lceport of 1 http://geohazards. usgs.gov/des ignmaps/us/summary. php?template=min. ra(GS Design Maps Summary Report User -Specified Input Report Title Building Code Reference Document Site Coordinates Site Soil Classification 4308 S. 131sT ST., TUKWILA, WA Mon October 14, 2013 21:43:07 UTC 2012 International Building Code (which utilizes USGS hazard data available in 2008) 47.48607°N, 122.27956°W Site Class D - "Stiff Soil" Risk Category I/II/III ISmi,; 5000n.i od'; ti East Icor G. Highlanc USGS-Provided Output Ss = 1.497 g S1 = 0.561 g Sp.'s = 1.497 g SMI = 0.842 g • 2013E ' Son = 0.998 g Sol = 0.561 g O MapQuest For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please retum to the application and select the "2009 NEHRP" building code reference document. t0 y 1.65 1.50 1.35 1.20 1.05 0.90 0.75 0.60 0.45 0.30 0.15 0.00 0.00 0.20 MCER Response Spectrum 0.40 0.60 0.20 1.00 1.20 1.40 1.60 1.20 Period, T (sec) 2.00 Ot t4 1A 1.10 1.00 0.90 0.90 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 0.00 0.20 Design Response Spectrum 0.40 0.60 0.20 1.00 1.20 1.40 Period, T (sec) 1.60 1.20 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter knowledge. 10/14/2013 2:43 PM Ac'ERMIT COORD COPY a PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-329 DATE: 10/17/13 PROJECT NAME: COSCO FIRE PROTECTION SITE ADDRESS: 4308 S 131 PL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: c-1> Building Division Public Works n Fire Prevention Structural Planning Division nPermit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 11 Incomplete Comments: DUE DATE: 10/22/13 Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: 111 Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required DATE: APPROVALS OR CORRECTIONS: DUE DATE: 11/19/13 Approved ❑ Approved with Conditions 1K1 Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: r PLAN REVIEW CHECKLIST - (Nonstructural) Permit App. 0/7"--32 By: IBC Edition /2_8( State Amend. Date: %041—/Y Project title: C.,05 -co riA '/61i^c- `coo r. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ );) Classify the building or portion thereof in accordance with Chapter 3 Determine the type of construction of the building in accordance with Chapter 6. Determine if the location of building on the site and clearances to property lines and other buildings on the site plan are in accordance with code provisions. Review for conformity with General building height and area limitations in accordance with Chapter 5. Review for conformity with special detailed requirements based on use and Occupancy. / Review for conformity with Type of Construction requirements of Chapter 6. Review for conformity with Fire and Smoke protection features of Chapter 7. Review for conformity with requirements of interior finishes of Chapter 8. Review for conformity with requirements for fire protection systems of Chapter 9. (3)-----"Tieview for conformity with requirements for means of egress requirements of Chapter 10 (� Review for conformity with requirements of accessibility in accordance with Chapter 11, and ICC A117.1 Review for conformity with Washington State Energy Code. //+++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ ✓ In circle = topic has been reviewed for the application. X In circle = topic is not relevant to proposed scope of work. Contractors or Tradespeop P, ter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COSCO FIRE PROTECTION INC UBI No. 601198501 Phone 4258279654 Status Active Address 15000 Woodinville/Redmond Rd License No. COSCOFP110NM Suite/Apt. SUITE B-800 License Type Construction Contractor City Woodinville Effective Date 8/14/1989 State WA Expiration Date 1/13/2015 Zip 98072 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status COSCOFP132JA COSCO FIRE PRO DV ZURN CON INC Construction Contractor Fire Protect System Unused 4/1/1987 4/1/1990 Archived COSCOFP178KPCOSCO FIRE PRO DV ZURN IND INC Construction Contractor Fire Protect System Unused 5/17/1983 4/1/1987 Archived COSCOFP285B8 COSCO FIRE PROTECTION CO Construction Contractor Fire Protect System Unused 1/28/1972 4/1/1984 Archived Business Owner Information Name Role Effective Date Expiration Date FIELDING, KEITH RYAN President 08/02/2012 Bond Amount CARRIER, TED Secretary 11/02/2007 K0878694A JUMP, ROGER Treasurer 11/02/2007 YOUNT, MICHAEL GEORGE President 02/14/2008 08/02/2012 O'CONNELL, JOHN P President 01/17/2002 02/14/2008 SHAFFER, STEVE Treasurer 01/17/2002 11/02/2007 KERN, DAVID Vice President 01/17/2002 11/02/2007 ELEK, EDWARD E President 01/01/1980 01/17/2002 POOL, DANIEL F Vice President 01/01/1980 01/17/2002 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 9 Westchester Fire Insurance Company K0878694A 11/12/2012 Until Cancelled $12,000.0011/13/2012 12/14/2012 8 American Contractors Indem CO 1000777964 07/06/2010 Until Cancelled 01/04/2013 $12,000.0007/09/2010 12/30/2011 7 American Contractors Indem CO 1000777964 11/12/2007 07/06/2010 $6,000.00 11/19/2007 6 GREAT AMER INS CO 5872830 12/01/2004 11/12/2007 $6,000.00 12/10/2004 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 31 Zurich American Ins Co GL0825002801 01/01/2013 01/01/2014 $5,000,000.00 12/14/2012 30 Zurich American Ins Co GL0825002800 01/01/2012 01/01/2013 $5,000,000.00 12/30/2011 https://fortress.wa.gov/lni/bbip/Print.aspx 11/04/2013 104'-5i" /7-1f\ r. 00 18'-9" ig 6" 44" X 144' 44" X 144" 0 0 0 m A 00 0 A EMERGENCY EXIT LIGHT TYP. SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing t Gas Piping City of Tukwila BUILDING DIVISION 1• , ... _.„. , A 36" X 108" A 36" X 108" A 36" X 108" 28' N A 36" X 108" A 36" X 108" 36 X 108" REVISIONS No changes shall bemade to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED OCT302013 City of u ila BUILDING VISION FILE COPY Permit No. 1093 "952--41 Plan review approval is subject to errors and omissions. Approval of construction documents does not authcri the Violation of any adopted code or ordinance. Receipt of approved Field Copy and conditions Is acknowledged: By /2• Date / 74/i3 City Of liakwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 172013 PERMIT CENTER w 8 N -S1 • EA �N �U • t r� N b4 8 al • -I �W U ""50 44t -at y� O 5 cv • •� E-1 ..4 0 DRAINING$ PREPARED FOR COCD EXPIRES 12-26-13 191) DRAWN BY JAL SC 3 16"=1'-0" 1/4/13 13 DRAWING NO: CHECKED BY: SHERT NO. 1 OF 2 suns A 1/8" Vl"<BOTH SIDES TYP. BRACING CONNECTION DETAIL --"I I-•-1/2., FLOOR ANCHOR DETAIL SEE NOTES FOR SPECS 1 1/2" , - -I .075 THK--- 1 1/4" SECT. A—A 5/8" DIA. 2 HOLES 3/8" THK. SECT. B—B 14GA THK. I 6"------I 8" BASE PLATE DETAIL (2)- /AvcxRI 3-1/4" EMB., (SEE NOTE NO. 4) .375 R I- 3“ � a � a o 2" TYP. AS NOTED 1/4" REF. 0 0 0 AN- .531 SQUARE 14GA THK. 7/8" 7 3", LM20 14GA ASTM A570 GR50 AS NOTED SINGLE Y4"0 SAFETY LOCK (1000# CAPACITY) 746"0 RIVET ASTM A576 -90B HOT -WROUGHT UNS G10100 GRACE C-1010 R1/8" I--3/4" TYP. LBC40 RACK TYPE "A" 4" BEAM FACE RACK DETAILS SCALE: 3/4" = 1" SINGLE RACK ELEVATIONS SCALE: 3/2" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED OCT 3 0 2013 City of Tukwila BUILDING DIVISION I-' 8 1 t"" I. 1 1 r rrrr p` L 1 I r i ....... RACK TYPE "A" 4" BEAM FACE RACK DETAILS SCALE: 3/4" = 1" SINGLE RACK ELEVATIONS SCALE: 3/2" = 1'-0" REVIEWED FOR CODE COMPLIANCE APPROVED OCT 3 0 2013 City of Tukwila BUILDING DIVISION RACK TYPE "B" 4" BEAM FACE STRUCTURAL NOTES: 1. DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2012 EDITION, SECTION 2209. 2. STEEL FOR ALL SHAPES FY=55 KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED). 3. NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR #777 (E70XX ELECTRODES). 4. ALL ANCHORS TO BE SIMPSON STRONG -BOLT 2 ICC -ES ESR -3037, SPECIAL INSPECTION IS REQUIRED. 5. CONCRETE SLAB 6" THICK 2,500 PSI. SOIL BEARING CAPACITY 1,000 PSF. 6. STORAGE RACK CAPACITY 1,500 #/ LEVEL AT TYPE "A" 2,000 #/ LEVEL AT TYPE "B" 7. RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY OF THE RACK (SEE NOTE NO. 6). 8. STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF l" IN 10'-0" OF HEIGHT. 9. THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP 0 THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. FIRE PROTECTION NOTES: 1. SPRINKLER DENSITY IS .495GPM OVER 2,000SQ FT. 2. SPRINKLER HEAD TEMPERATURE IS SET AT 286°F. STEEL. ? c,w‘15=&Jc'- 3. CLASS IV COMMODITY, ! ), STORED ON CONVENTIONAL WOOD PALLETS, NON -ENCAPSULATED. 4. TOP OF STORED PRODUCT NOT TO EXCEED 20'-0". 5. APPROXIMATE CEILING HEIGHT 29'-6". EXITING NOTES: 1. EXTERIOR DOORS ARE 3' SWING TYPE WITH LOCKING KNOB WHICH REQUIRES NO SPECIAL KNOWLEDGE OR EFFORT TO OPEN. RECEIVED CITY OF TUKWILA OCT 1 7 2013 PERMIT CENTER 32q EXPIRES 12-26-13 1 4.2 40 110111 1116'i 003, T:11 MOHR O cip 3 5 >"',(1)gc)w z New U c5 N •.� Ems-+ y ct3 E o DRA$JINCS' PREPARED FOR 0 00 C0 00 07 J 1- U DRAWN 8Y: JAL SCALE: AS SHOWN DAM 10/4/13 DRAWING" NO: CI KED BY: S RI' NO. 2 of 2 SHEETS I-' 8 1 I. 1 _, r 1 r rrrr p` L RACK TYPE "B" 4" BEAM FACE STRUCTURAL NOTES: 1. DESIGN OF STEEL STORAGE RACKS AS SHOWN BY THESE DRAWINGS AND CALCULATIONS ARE IN COMPLIANCE WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE 2012 EDITION, SECTION 2209. 2. STEEL FOR ALL SHAPES FY=55 KSI. ASTM A1011 GR.55 (EXCEPT AS NOTED). 3. NO FIELD WELDING IN THIS PROJECT ALL WELDED CONSTRUCTION IN THE SHOP OF THE APPROVED FABRICATOR #777 (E70XX ELECTRODES). 4. ALL ANCHORS TO BE SIMPSON STRONG -BOLT 2 ICC -ES ESR -3037, SPECIAL INSPECTION IS REQUIRED. 5. CONCRETE SLAB 6" THICK 2,500 PSI. SOIL BEARING CAPACITY 1,000 PSF. 6. STORAGE RACK CAPACITY 1,500 #/ LEVEL AT TYPE "A" 2,000 #/ LEVEL AT TYPE "B" 7. RACK INSTALLATIONS SHALL DISPLAY IN ONE OR MORE CONSPICUOUS LOCATIONS A PERMANENT SIGN OF 50 SQUARE INCHES IN AREA, SHOWING THE CAPACITY OF THE RACK (SEE NOTE NO. 6). 8. STORAGE RACKS SHALL BE INSTALLED WITH A MAXIMUM TOLERANCE FROM THE VERTICAL OF l" IN 10'-0" OF HEIGHT. 9. THE CLEAR SPACE BELOW SPRINKLERS SHALL BE A MINIMUM OF 18 INCHES BETWEEN THE TOP 0 THE STORAGE AND THE CEILING SPRINKLER DEFLECTOR. FIRE PROTECTION NOTES: 1. SPRINKLER DENSITY IS .495GPM OVER 2,000SQ FT. 2. SPRINKLER HEAD TEMPERATURE IS SET AT 286°F. STEEL. ? c,w‘15=&Jc'- 3. CLASS IV COMMODITY, ! ), STORED ON CONVENTIONAL WOOD PALLETS, NON -ENCAPSULATED. 4. TOP OF STORED PRODUCT NOT TO EXCEED 20'-0". 5. APPROXIMATE CEILING HEIGHT 29'-6". EXITING NOTES: 1. EXTERIOR DOORS ARE 3' SWING TYPE WITH LOCKING KNOB WHICH REQUIRES NO SPECIAL KNOWLEDGE OR EFFORT TO OPEN. RECEIVED CITY OF TUKWILA OCT 1 7 2013 PERMIT CENTER 32q EXPIRES 12-26-13 1 4.2 40 110111 1116'i 003, T:11 MOHR O cip 3 5 >"',(1)gc)w z New U c5 N •.� Ems-+ y ct3 E o DRA$JINCS' PREPARED FOR 0 00 C0 00 07 J 1- U DRAWN 8Y: JAL SCALE: AS SHOWN DAM 10/4/13 DRAWING" NO: CI KED BY: S RI' NO. 2 of 2 SHEETS