Loading...
HomeMy WebLinkAboutPermit D13-336 - ATLAS SALES & RENTALS - TENANT IMPROVEMENTATLAS SALES & RENTALS 18441 CASCADE AVE S D13-336 • >�y City of Tukwila ti Department of Community Development �! 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.Rov Parcel No: Address: Project Name: � Jr r d OOO�IV 1 )44 • CletCk irOCkJ Ci DEVELOPMENT PERMIT ATLAS SALES & RENTALS Permit Number: D13-336 Issue Date: 11/18/2013 Permit Expires On: 5/17/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: CWWATUKWILA 1 LLC C/O EQUITY OFFICE MGMT LLC PO BOX A-3879, CHICAGO IL, , 60690 CAREY FERGUSON 500 SW 16 ST , RENTON WA, , 98057 MR RACKS LLC 500 SW 16 ST, RENTON, WA, 98057 MRRACRL924BN N/A < $5,000.00 Phone: (253) 569-9765 Phone: (425) 207-0058 Expiration Date: DESCRIPTION OF WORK: SUBTYPE: AWSE STATUS: PENDING DESCRIPTION: PALLET RACKING Project Valuation: $2,647.00 Type of Fire Protection: Sprinklers: Fire Alarm: NO Type of Construction: Occupancy per IBC: Electrical Service Provided by: TUKWILA FIRE SERVICE Water District: TUKWILA Sewer District: TUKWILA SEWER SERVICE Fees Collected: $250.52 Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Public Works Activities: Channelization/Striping: Curb Cut/Access/Sidewalk: Fire Loop Hydrant: N N N Flood Control Zone: Hauling/Oversize Load: Land Altering: Landscape Irrigation: Sanitary Side Sewer: Sewer Main Extension: Storm Drainage: Street Use: Water Main Extension: N Volumes: Cut: 0 Fill: 0 Number: 0 Water Meter: Yes Permit Center Authorized Signature: Date: //(//3 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: �'� 5 - Date: //7j�-0/-7 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***BUILDING PERMIT CONDITIONS*** 2: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 5: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 6: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 10: Portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Portable fire extinguishers having a gross weight not exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 5 feet (1524 mm) above the floor. Hand-held portable fire extinguishers having a gross weight exceeding 40 pounds (18 kg) shall be installed so that its top is not more than 3.5 feet (1067 mm) above the floor. The clearance between the floor and the bottom of the installed hand-held extinguishers shall not be less than 4 inches (102 mm). (IFC 906.7 and IFC 906.9) 11: Extinguishers shall be located in conspicuous locations where they will be readily accessible and immediately available for use. These locations shall be along normal paths of travel, unless the fire code official determines that the hazard posed indicates the need for placement away from normal paths of travel. (IFC 906.5) 12: Fire extinguishers require monthly and yearly inspections. They must have a tag or label securely attached that indicates the month and year that the inspection was performed and shall identify the company or person performing the service. Every six years stored pressure extinguishers shall be emptied and subjected to the applicable recharge procedures. If the required monthly and yearly inspections of the fire extinguisher(s) are not accomplished or the inspection tag is not completed, a reputable fire extinguisher service company will be required to conduct these required surveys. (NFPA 10, 4-3, 4-4) 13: The total number of fire extinguishers required for a light hazard occupancy with Class A fire hazards is calculated at one extinguisher for each 3,000 sq. ft. of area. The extinguisher(s) should be of the "all purpose" (2A, 10 B:C) dry chemical type. The travel distance to any extinguisher must be 75' or less. (IFC 906.3) (NFPA 10, 3-2.1) 14: Maintain fire extinguisher coverage throughout. 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 16: Maintain fire alarm system audible/visual notification. Addition/relocation of walls or partitions may require relocation and/or addition of audible/visual notification devices. (City Ordinance #2328) 17: Clearance between ignition sources, such as light fixtures, heaters and flame -producing devices, and combustible materials shall be maintained in an approved manner. (IFC 305.1) 18: Where storage height exceeds 15 feet and ceiling sprinklers only are installed, fire protection by one of the following methods is required for steel building columns located within racks: (a) one-hour fire proofing, (b) sidewall sprinkler at the 15 foot elevation of the column, (c) ceiling sprinkler density minimums as determined by the Tukwila Fire Prevention Bureau. (NFPA 13) 19: Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. (IFC 315.2.1) 20: Flue spaces shall be provided in accordance with International Fire Code Table 2308.3. Required flue spaces shall be maintained. 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1700 BUILDING FINAL** 1400 FIRE FINAL • CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Building Permit No. b 17- 33 b Project No. /, Date Application Accepted: IO 1q ( 3 (For office use only) Date Application Expires: CONSTRUCTION PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION 1 t'L.� \ uktie, ki C' — i Site Address: / Tenant Name: >46Qs ShAS , :O, King Co Assessor's Tax No.: Suite Number: PROPERTY OWNER /1 Name: /?pp gent. 4,41/ (�t'rle(-%t"1.kap4 Address: /0b /i0/ 1.Skire 6-tvet 4- 700 CitKs it �e zie A. State: C.A. Zip:90 / CONTACT PERSON - person receiving all project communication Name: `li T S (X— Address: foo s,z6 /�%�[ 57/.. City: Jfl /l.. State/i )A Zi9j2 sem% /5x9/4 Phone: /o�S3. s/7� ZFFJax:i/�5do7 Email: 4 Prue -i m/%Gt4s , dD it t GENERAL CONTRACTOR INFORMATION Company Name: g • 4 .5 LLe--• Address: 0 57,0 ` SGf?5/ `.�Lam City: A State: A Zip' Go 67 Phone: a5,5w, C)n` 'ax. ZS �7� feo 1��4lj/ !C(o9z. Contr Reg No.:,(,� /B,/Exp Date: �� ,/1 `f �1 / Tukwila Business License No.: S _00,0 3 2 H:\Applications\Forms-Applications On Line \2011 Applications \Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Floor: New Tenant: ❑ Yes ..No ARCHITECT OF RECORD Company Name:( /�t / ,7//Q,.(� /Q �f1 �� /G� Engineer Name: �/ iJ '/�- b7 7 1< (/az, Company Name: ' City: .t. State )� A. Zilfia3/ ,4 G ' gs/ 730Fpx: Phone: oz 4 .7 Architect Name: Address: City: State: Zip: Phone: Fax: Email: ENGINEER OF RECORD Company Name:( /�t / ,7//Q,.(� /Q �f1 �� /G� Engineer Name: �/ iJ '/�- b7 7 1< (/az, Address: z //2.2_ - ,L�`7crJt�/s C City: .t. State )� A. Zilfia3/ ,4 G ' gs/ 730Fpx: Phone: oz 4 .7 Email: LENDER/BOND ISSUED (required for projects $5,000 or greater per RCW 19.27.095) Name: Address: City: State: Zip: Page 1 of 4 s BUILDING PERMIT INFORMATION — 206-431-3670 Valuation of Project (contractor's bid price): $ 074 Describe the scope of work (please provide detailed information): Will there be new rack storage? ❑ Yes Existing Building Valuation: $ E.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC 1St Floor 2nd Floor 3rd Floor Floors thru Basement Accessory Structure* Attached Garage Detached Garage Attached Carport Detached Carport Covered Deck Uncovered Deck PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor area of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes ❑ No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: 0 Sprinklers ❑ Automatic Fire Alarm 0 None 0 Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes 0 No If "yes', attach list of materials and storage locations on a separate 8-1/2" x 11" paper including quantities and Material Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line \2011 Applications\Permit Application Revised - 8-9-I I.docx Revised: August 2011 bh Page 2 of 4 PERMIT APPLICATION NOTES — Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 0 Signature: Print Name: Mailing Address: C5 4) 76 H:\Applications\Forms-Applications On Line \201 I Applications \Permit Application Revised - 8-9-1 I.docx Revised: August 2011 bh Date: /07:// 3 State c -e.-5 Day Telephone: Oel: 0953 7 M'Ati Zip Page 4 of 4 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK. ACCOUNT QUANTITY PAID $65.00 D13-336 Address: 18441 CASCADE AVE S Apn: 7888900040 $65.00 DEVELOPMENT $65.00 ADDITIONAL PLAN REVIEW TOTAL FEES PAID BY RECEIPT: R528 R000.345.830.00.00 $65.00 $65.00 Date Paid: Tuesday, December 31, 2013 Paid By: MR. RACKS Pay Method: CHECK 3887 Printed: Tuesday, December 31, 2013 11:12 AM 1 of 1 CRWSYSTEMS 410 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.Tukw ila WA.gov Parcel No.: 2523049071 Address: 1091 INDUSTRY DR TUKW Suite No: Applicant: ATLAS SALES & RENTALS RECEIPT Permit Number: D13-336 Status: PENDING Applied Date: 10/29/2013 Issue Date: Receipt No.: R13-03001 Initials: User ID: WER 1655 Payment Amount: $250.52 Payment Date: 10/29/2013 11:18 AM Balance: $0.00 Payee: MR RACKS TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3766 250.52 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - NONRES PLAN CHECK - NONRES STATE BUILDING SURCHARGE 000.322.100 000.345.830 640.237.114 Total: $250.52 149.10 96.92 4.50 Ant— Raraint-nf Printed: 10-29-2013 \T IJ • INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. p/3-33(0 CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:.���� � Type of Inspection:—E, xt- Address: igtAfil Cw,c4de Date Called: M Special Instructions: S Date Wanted: J J m. 01/12,7 1 p.m. Requester: „ask Phone No: 2_0& - ` OSST '.Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1.112. S pp(r # (. T i,uS1 it trt5 ctor: J •l..' RE SPECTION FEE REQUIRED. Prior to ext inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. `all to schedule reinspection. INSPECTION RECORD\ Retain. a copy with permit -.J ,b13-33 NO. INSPECTION NO. PERMIT N CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro ct:S SA -( . e Ari is �-s / Typ f Inspe �ionn: \ L5 , vAt� Address: X 84-4-1 ci-s LAb F Date Called: Special Instructions: 00 Date Wanted: -- � S_ 1 '��• P.m. Requester:. Phone No: • JApproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspe Date r U ` (/ REINSPECTION FEE REQUIRED Prior to next inspection, fee must be • paid at 6300 Southcenter. Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit D'3 -33(n PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project:�`---, 5 Q -S ' L. P ,�9f-' Type of Inspection: '.t'\( -k.-1 r GC_ Address: ` Suite #: ) 6A6\ \ CG.SC . AN S Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Needs Shift Inspection: pie. s Sprinklers: • Fire Alarm: Hood & Duct: , -,,, Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: `�-c---,,mc) Date: 4114k (4 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 Fireproofing Aggregates Shotcrete Concrete Masonry Asphalt Roofing P iling S teel S oils Wood April 15, 2014 File No. 14-130 Building Official City of Tukwila Building Department 6300 Southcenter Blvd. Tukwila, WA 98188 Project: Address: Permit: Atlas Sales and Rentals 18441 Cascade Ave. S. D13 336 A.A.R. TESTING LABORATORY, INC. CONSTRUCTION INSPECTION A*.OMATERIAL TESTING NATIONALLY ACCEPTED LABORATORY This is to advise you that special inspections are completed on the above referenced project. The following inspection was required and a copy of our inspection report has already been forwarded to you. 1. Proprietary anchor installation To the best of our knowledge all work inspected conformed to Tukwila Building Department approved plans, specifications, IBC and related codes and/or verbal or written instructions from the Engineer of Record. Sincerely, A.A.R. TESTING LABORATORY, INC. feA-t_ita aibt0; Kimberle Anderson President CC: Mr. Racks -Carey Ferguson Altas Sales and Rental -Josh Bond Tel: (425) 881-5812 Fax (425) 881-5441 • 7126 180th Ave. NE 0 P.O. Box 2523 • Redmond, WA 98073 Client: Mr. Racks 500 S.W. 16th St. Renton, WA 98057 Contact: Carey Ferguson Field Report Report*: 059252 Project Number: 14-130 Permit #: D13 336 Project Name: Atlas Sales and Rentals Address: 18441 Cascade Ave. S. Inspection Performed: Proprietary Anchors Date: 1/15/2014 Time: Temperature: Anchor bolts for pallet racks. 4 anchors missing on east end of south row. Non conforming item. Distribution: ® Distribute Client E Distribute Contractor ❑ Distribute Engineer ❑ Distribute Owner © Distribute Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other Inspector: Trow, Michael Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden Client: Mr. Racks 500 S.W. 16th St. Renton, WA 98057 Contact: Carey Ferguson Field Report Report #: 059254 Project Number: 14-130 Permit #: D13 336 Project Name: Atlas Sales and Rentals Address: 18441 Cascade Ave. S. Inspection Performed: Proprietary Anchors Date: 1/22/2014 Time: Temperature: Anchor bolts for pallet racks 11 bays total. Verged installation of Simpson Strong bolt 2 anchors 1/2" x 4 3/4" with 3" embed torqued to 60 ft./lbs. All placed per plan. Distribution: © Distribute Client ❑ Distribute Contractor ❑ Distribute Engineer ❑ Distribute Owner Q Distribute Municipality ❑ Distribute Other ❑ Distribute Architect ❑ Distribute Other Inspector: Trow, Michael Reviewed by: Mike Blackwell All reports are considered confidential and are the property of the client and A.A.R. Testing Laboratory, Inc. Reproduction except in full without the written consent of A.A.R. Testing is strictly forbidden Job Title A r Cols 5/31.6- 30 /lEurAlo -1 4J r t.A GN.4 By 837tc Subject ST t_ 5eLecTtue /aAC.k 0Af,.:I I3 Date /0- Z013 Job No. 130 Checked Sheet % of 3 tiS6 TOE. tom t Sts, twq , IRE 1.001 g.m r cDP6 k..1t7 & . IS. S,? Oi- As 1-tc► fcaALt./sis• -rut ASI? ul A, r1100 'I . 0.4v1 C -r Ce 0, '14- L a I.o PuLuigi s ,Jor A 063 , Ai rry4C tL( re-/ = 62/4) ( tit x4s)/j :.s s i•414 rit. WE. leQ()iWSs Ft e.> Foot :1*'tr , t.ess D . ? 4., o Tit A i,/i;1. ( PULED) 1).. , 11; a 9.p14- 40,0 .1'd4-40,0 Low,r (,wee.) " YL . 0.1.054 Os PILE Copy G)s = 0. t¢-1. . pt f vt. .. 2LL. t i a.e u. Pennit No. /.44v- 044-to/A-0 to tom. d a- 1 pAt R F i t rh s 3, coo tg, w too tis f Lev t_ i=& t Dc. 3,000 41 Ftv. Pt1 usF 1.0 01 eDrW DiAtra-jaas C�) s TCPE 6 REVIEWED FOR CODE CC?►t ` L APPROVED NOV 14 2013 City of Tukwila BUILDING DIV L 1E A- tt A ct; J Ws a 0, Wt 3, fo, 4- ft9o 2445. tel ftr=J - 0, 1634.,e2,,i„tAis d I36,0 Seis M. i os. 4 4 k" a 4-2 - 3+ 3€3 �,W f •-t t3 p s 2--7° !`t ai P- E.45 77 .2.S1` V . o. 34 14' qtr is Jet ®,.icy VT. i6.5 Oil' S 1 i 4r 7i 0,61'4, /37,Pc Cv"y' ! . $ P.15-(1.10÷ 3,50) 4- . 10 : 4. / k f P E -AA&KJ t tit r . t.i 1004, : Zito '/ t er' 47 v.. f!, ts'C 2 2.110 t9. id.$ k s? 13413 " 6*u M get too te.`' Q - 3 w 5e1,3 12, s 2.30 C,t4af {1... 2.1 t 14 "t,. • O, t V Loon 0 r.) is p tell olgc. y vt r st. 0,49i " e 466" , ]- 7 . 0 4.1 14 AA +e w � r a 0 .1S. C 2.3 o #- 3.0) 4- o ,/o m 408 lc J 2- Yz496. 4 3i¢f g,rnp5ti) sn , 6s 6taz 'L At$60Ge A,) Ca.s t 1.1 hal) 1 ,. Ptd 2t 50 i-rcc-ES Est.- 3631 10f7sa �/�e,c..iic '‚‚'°aJ 214-1 e• l+► n = �, t olc.E t !< s 5 5. 41C Wit at j, CA... 12 .,il , t U. RECEIVED T/TA + VivA * 0 . 5 t 44A..) — BSC G Lao CITY OF TUKWILA D. /4 13- 33(p 2013 PERMIT CENTER Job Title Subject By 10.41(... Date to - 'LE7E 3 Job No. 130 .L1 Checked Sheet 2-. of SOL I NI 4 I Mkt of z v,17S k - TVAE A -! � >RA0cc � 3 \ •r ©.Sty lA6.O•t1A`L r C3D�Z -i- ��'9i ..c# 41.>ED Dii6. (3RpCC 1.7: 1.21 .7s F + (9.5S 14 02t4.. t6QAr,61 .6784 1 fL k jet. x 1;(. Gt0 C. Str t:.; I vA1i A . 1 o .216 ,'' .�s,t da { • O.4 ., '04 k �kG. jr $ 180. € 2 N. 1, v) =air1 z P, . A<< 350 - > 0.75 P ♦tAst FLA r t%i SL.A 6 gmt t !�- 414 it Ce,.rly) 4.71- !3A s6 pt~1+r6z Ape S x $'. 34 " *' 4 to 44.tta T + r o. lig M - Q A tto r a lei. 7,0 ki.. $G l9tArt- nt aD.»ok[?.Tj''-13 s, o, 372 k"/. 414-0L) fr • 0.7s- % S 17 is: PZQtto (9. ZU -4,A c S B 77tdC.l4. Crvlc. 51444 b) 7):i •' 2, Soo gyp. Scht Aadw -rt = S‘Cfc'frA) • 94 p$: 5L4-6 .QUA fi . ©t>* x SO. o Il 2 a 0.3 12 sC -P 0.3412 s pCa)Y2 °shad, ,3 4,) fo . 1.0 144 37 L a ID.i,LS E9t. AAA At • (2a 4. 3,0 .S.o)(2a+ o Per Ab x A1t4:4r t s 7.43k --Dig )► /Aaw Cxrntp Leh44 .. r, bh it. « Type e.. gAGics o.tos4, 4.2x 2.,110/2 s fl. 223 kItot . 1. P. ois i k Fix v,/34' i $604s Aak 14- ff,a -r►" PAJe A s" Ftta G" a11 At tt r it STD £J&L4 teilmt; sz 3.141 f.10i G" > eL tter, MA s 12 , 4-3 k." STt� 1416 cA, MA * 11.12 C*4712.0 S 3�8 3+b`� 0.i34, .rte w 1.tA°`. 0.124 Ubt,J+; A Ss(3.t44) 4 ►lOj8 : 27.0o k tMolt) ts7.env rigxrui root Gf,Jtvtry 14)403 E1,1© ) . D.15 ( 4.14-4. .Js;k 24.Z 1+ •tSk 0.'15' . 1.4-j k" AIA M • Z2.is tog '7 = 11.18 kk - sok L ry a 3o tcs A+ : 0, VI - o k de. L1480 a tD dr7 Job Title Subject Date 10 - ZO t $ Job No. 130 � 7 Checked Sheet 3 or Ae s e.581 h • �1106 Sx34 4 GA C S Cr! Wit's 344* (2.E71.440 Lips 44, 71.s' 141 42" P9 o,ls(3.0) a- 0,10 a 2,35t` Mx 0.75x8.4, G.4-$ axe.. 9.9341 14.1 •0.131 .t.4o wee S,i D. 413 Met3 7 - .00 t * rx 1.2/0 � . L►4S " 0411ri,4 JOtt--SC- CoA1r Gi if; . 3.2.9t" q VIA a 24.43 k (4 1DD. 4-S" kg - (C to. L. im 0 = 4.04103 It-• I� i rb . 30 fe1,1: 151e 'tr 01% : 19,13 1 o Cc D.t�S S Q = 0.3" 0.4-3 D, tt c 1-0,04 (AAA c.osite P4 . 4.0e- AfC`� • v. G8 — < 1.0 9/2/2014 City of Tukwila Department of Community Development CAREY FERGUSON 500 SW 16 ST RENTON WA, 98057 RE: Permit No. D13-336 ATLAS SALES & RENTALS 1091 INDUSTRY DR Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/15/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/15/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall Technician Fi No D13-336 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 4/1/2014 City of Tukwila Department of Community Development CAREY FERGUSON 500 SW 16 ST RENTON WA, 98057 RE: Permit No. D13-336 ATLAS SL & RENTALS l IND Y DR C of 5 Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 5/17/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 5/17/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Jenn Per Lpat fer Marshall it Technician File No: D13-336 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 •PERMIT COORD COPY. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-336 DATE: 12/06/13 PROJECT NAME: ATLAS SALES & RENTALS SITE ADDRESS: 18441 CASCADE AVE S Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: Buil ing Division Public Works Ay\ nyA - 13 Fire Prevention Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12/10/13 Complete 11 Incomplete n Not Applicable El Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 1-1 REVIEWER'S INITIALS: Structural Review Required n No further Review Required C DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/07/14 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: D13-336 DATE: 10-29-13 PROJECT NAME: ATLAS SALES & RENTALS SITE ADDRESS: 1091 INDUSTRY DR X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS: ding Division Fire Prevention Public Works Structural ll`c2.(5 Planning Division Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 10-31-13 Complete [)ti Incomplete n Not Applicable Comments: Permit. Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 11-28-13 Approved with Conditions1.5‹Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 PROJECT NAME: e PERMIT NO: I�� � SITE ADDRESS: t 141'11 rl�C�i � ' Ave.fil'C ORIGINAL ISSUE DATE: REVISION LOG REVISION NO.INITIALS DATE RECEIVED i STAFF ISSUED DATE STAFF INITIALS OW 11) --jr,A'— Summary of Revision: Summary of Revision: vt pp ?t, N '-p Y2. p 9-12-- CNS J (IE A-790 w YLYOr C --C- mut Pl r 'r Received by: Off C (UnOe REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1 I12-43 0 Response to Incomplete Letter # 0 Response to Correction Letter # Xj Revision # ( after Permit is Issued Plan Check/Permit Number: 0 .L)1.3 -33G Revision requested by a City Building Inspector or Plans Examiner Project Name: Allas -Ads Project Address: ,rIJ41/ LG45t�'. Q j/p, S. Contact Person: OkapA -Af1 Summary of Revision: Ori 'a /JJI $led )07nX addr?mss I) rel , r -e v,`sem 6A-0142 6-e_)10";:a7 yYt .e 7- ( s '.) 741 077 e -e- f2-.5" Ltk' - 11 l"-�S RECEIVED OIT1l DSC :0 6 2013 PERMrT caret /itsk_z.J/ /t G()A 9J/Rer Phone Number: aeY, Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: J21- Entered in Permits Plus on \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: 1-2009 Contractors or Tradespeople ter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MR RACKS LLC UBI No. 602779014 Phone 4252070058 Status Active Address 500 Sw 16Th St License No. MRRACRL924BN Suite/Apt. License type Construction Contractor City Renton Effective Date 1/3/2008 State WA Expiration Date 1/17/2014 Zip 98057 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status MRRACR'94301 MR RACKS Construction Contractor Inst Equip/Stat Furn/Lab T/Lo Unused 9/21/2006 9/21/2008 Re - Licensed Business Owner Information Name Role Effective Date Expiration Date FERGUSON, CAREY SCOTT Agent 04/30/2013 Amount FERGUSON, CAREY SCOTT Partner/Member 04/30/2013 BKS 54574031 FERGUSON, JULIE LYNN Partner/Member 04/30/2013 GONSER, BRETT Partner/Member 01/03/2008 04/30/2013 MCLENDON, ROBERT Partner/Member 01/03/2008 04/30/2013 Bond Information Bond Company Name AMERICAN CONTRACTORS INDEM CO Bond 1 Page 1 of 2 Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 100031015 12/20/2007 Until Cancelled $12,000.00 01/03/2008 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 Ohio Security Ins Co BKS 54574031 06/29/2013 06/29/2014 $1,000,000.0006/11 /2013 7 Ohio Security Ins Co BKS 13 54574031 06/29/2012 06/29/2013 $1,000,000.0005/21/2012 6 Ohio Security Ins Co 54574031 08/23/2011 06/29/2012 $1,000,000.0008/22/2011 5 MAXUM INDEMNITY CO BDG004678901 08/23/2010 08/23/2011 $1,000,000.0008/23/2010 4 LIBERTY NORTHWEST INS CORP BH0115367338608/24/2010 08/24/2011 $1,000,000.0007/21/2010 3 LIBERTY NORTHWEST INS CORP bho1053673386 08/24/2009 08/24/2010 $300,000.0007/23/2009 2 OHIO CAS INS BH00953673386 08/24/2008 08/24/2009 $300,000.00 07/29/2008 1 08/24/2007 • 08/24/2008 $300,000.0001/03/2008 httns://fortress.wa.gov/lni/bbip/Print.aspx 11/18/2013 NOTES: 1. ALL PALLET RACK POSITIONED TO LEAVE A 6" FLU SPACE MINIMUM ON ALL SIDES WHEN LOADED. 2. SHELF SUPPORTSARE WIRE DECK 3. WAREHOUSE AREA IS 13,048 SQ. FT. r L J 39'-10" 6' 84'-10" 0 ,r 36'" r r L J = SMOKE VENTS L J r 42" X 120" 42" X 120" 42" X 120" r stz L J 42" X 120" 42" X 120" 48" X 120" 48" X 120" 48" X 120" 48" X 120" 48" X 120" REVIEWED FOR CODE COMPLIANCE CE APPROVED DEC 13 2013 City of BUILDING 42" X 120' SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION 147 a REVISIONS No Changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submitts and may include additional plan review fess. // FILE COPY Petmit No. Plan review approval is subject to mom and onssions rovai of construe on documents does not authorize the violation of any adopted code or ordnance. Receipt is acknosiedged: K ,!� Copy i rl,i i i r., � WRs •. / , 44 Deg IR OM RECEIVED CITY OF TUKWILA DEC 0 6 2013 PERMIT CENTER City Of 'Nitwits BUILDING DIVISION iia ISION RVISION NO. I 1)4G;10 ti cs M ti cry 00 V) 00 0 0 DRAWN BY:: NICE - SCALE: 3/ 16" DATE: 12-2 13 DRAWING NO: CHECKED BY: B. Kattula SHEET NO. OP 1 SHEETS NOTES: 1. ALL PALLET RACK POSITIONED TO LEAVE A 6" FLU SPACE MINIMUM ON ALL SIDES WHEN LOADED. 2. SHELF SUPPORTS ARE WIRE DECK 3. WAREHOUSE AREA IS 13,048 SQ. FT. r = SMOKE VENTS L 146-10" ADJACENT TENANT THIS SIDE 1\ 1 1 1 1 1 1 ,. r L F A rn 3 A 42" X 120" A 42" X 120" L A 42" X 120 A 42" X 120"1 B 42" X 1207 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 14 2013 City of : ila BUILDING ► ISION A 48" X 120" A 48" X 120" SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing 0 Gas Piping City of Tukwila BUILDING DIVISION 146-10" ADJACENT TENANT THIS SIDE A 48" X 120' A 48" X 120" 1 A 48" X 120" REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees, 0 00 ) SPECIAL INSPECTION FOR STORAGE RACKS (OVER 8 FEET) (IBC 1707.5.11.7) Periodic special inspection is required during the anchorage of storage racks 8 feet or greater in height in structures assigned to Seismic Design Category D, E or F. and TABLE 1705.3 (#4) Inspection of anchors post - installed in hardened concrete members. FILE COPY Permit No. P 1;-929-4 Plan review approval Is subject to errors and omissions. Approval of construction documents does not authorize the violation of any adopted code or ordinance. Receipt of approved Field and conditions is acknowledged: BY /1 City Of Ttdkwila BUILDING DIVISION b13"-- 3. )l3 RECEIVED CITY OF TUKWILA OCT z 9 2013 //) PERMIT CENTER 4-4 DESCRIPTION 0 40 pi Ail I 425-207-0058 500 S.W. 16th St. Renton, WA :04 oo 0tol Nca 99 174 Cf) LLJ ems. w LU 00 0, 0 0 F.- 00 :D 0 DRAWN BY: JF/CF SCALE: 1/8" = 1' DATE: 10-13-13 OF 2 SHEETS DRAWING NO: CHECKED BY: Kattula SHEET NO. 1 .375 R 2" TYP. AS NOTED r-1/4" REF. 0 0 0 0 — 3'-6" OR 4'-0" SIDE 3" 1 .531 SQUARE 1/8" 14GA THK. 7/8" 3" --I 1--3/4" COLUMN DETAII., ALL RACK TYPES T 10' RACK TYPE A R1/8" TYP. 11/2" t 1-'I12 r " 14 GA THIC COLUMN STRUT FRONT 1 3'-6" SIDE 1 -4 10' 7 RACK TYPE B RACK ELEVATIONS SCALE: 3/8" = 1' 6" r AS NOTED i I 1 BEAM SECTION 14 GA THK. ASTM A570 GR50 5" BEAM DETAIL ALL RACK TYPES FRONT REVIEWED FOR CODE COMPLIANCE APPROVED NOV 14 2013 City of Tukwila UIL.DING DIVISION STRUCTURAL NOTES: 1. RACKS ARE MANUFACTURED BY LODI METAL TECH (LM.T) OF LODI, CA OR EQUAL 2. MINIMUM YIELD (Py) AND ULTIMATE (Fu) STEEL STRENGTHS SHALL BE AS FOLLOWS: (a) BEAMS AND COLUMNS Fy50ksi Fir=65ksi. (b) BRACING STRUTS Fy36ksi Fu58ksi. (c) BASE PLATES FY=36ksi F58ksi. 3. MAXIMUM RACK LOAD PER LEVEL PER PAIR OF BEAMS SHALL BE AS FOLLOWS: (a) RACKS TYPE A: 3,500 LBS (b) RACKS TYPE B: 3,000 LBS 4. CONCRETE SLAB IS GIVEN AS 5" THICK WITH fc"=2,500 psi. 5. ALLOWABLE SOIL BEARING PRESSURE IS GIVEN AS 1,000psf FOR GRAVITY LOADS. 6. TIE -DOWN ANCHORS SHALL BE SIMPSON STRONG BOLT 2 WEDGE ANCHORS. USE TWO (2) 1/2"O X4-3/4" ANCHORS WITH. A 3" EMBEDMENT PERBASEPLATE SPECIAL INSPECTION IS REQUIRED. 7. POST LOAD SIGNS NOT LESS THAN 50 SQUARE INCHES IN AREA SPECIFYING THE DESIGN CAPACITY AT CONSPICUOUS LOCATIONS. S. IF ANY DISCREPANCY OCCURS, CONTACT THE ENGINEER FOR CLARIFICATION. 9. ANALYSIS AND DESIGN OF RACK CONFORMS TO THE 2012 IBC SEC 2209, THE 2008 RMI CODE, AND SEC. 15.5.3 OF SEI/ASCE 7-10 USING THE ASD METHOD WHERE: V = 0.67 Cs Ip Ws AND IP= 1.0 (RESTRICTED AREA NO PUBLIC ALLOWED) 0,3303 S$. 1669 I,"4. C8 = 2.5 Ca/R AND Ca = faffhtFOR THE GIVEN ADDRESS AND SITE CLASS D 0.531 R = 4.0 BRACED DIR. - TRANSVERSE (BRACED) DIR. Fa 1.0 R = 6.0 UNBRACED DIR. - LONGITUDINAL (MOMENT) DIR. FIRE PROTECTION NOTES: 1. SPRINKLER SYSTEM DENSITY E4 39 GPM/5,600 SQ. Fr- HEAD TEMP IS 286° 2. TYPE OF PRODUCT: CLASS I -W AIR EXCHANGERS 3. TOP OF STORED PRODUCT NOT TO EXCEED 18'-6" 4. APPROXIMATE CEILING HEIGHT 24'-0". EXITING NOTES: 1. EXTERIOR DOORS ARE 3' SWING TYPE WITH LOCKING KNOB WHICH REQUIRES NO SPECIAL KNOWLEDGE OR EFFORT TO OPEN. 2. EXTERIOR EXIT DOORS TO BE MARKED PER APPLICABLE CODE sr? 1 wr 31)(p BASE PLATE ALL RACK TYPES RACK DETAILS SCALE: 3" = 1' 3/8" THK 1/2" t r"-1 4-3/4" 1 FLOOR ANCHOR DETAIL SEE NOTES FOR SPECS ALL RACK TYPES BRACING CONNECTION DETAIL ALL RACK TYPES /d 114iiCEIV - ED CITY OF TUKWILA OCT 2 9 2013 PERMIT CENTER DESCRIPTION A Nip 0 co lar MI I I z 14 pg Cie 425-207-0058 0 co Cr) CO A ) LER -A :;: ;77::00 00 �(. ILNJ D �vT 9 N- vmn `— ` _.% 0- H"" F— DRAWN BY: JF/CF SCALE AS SHOWN DATE: 10-13-13 DRAWING NO: CHECKED BY Be Kattula SHEET NO. 9 OF 2 SHEETS 1