Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-002 - DOUBLE TREE HOTEL - ROOF TOP A/C UNIT
DOUBLE TREE HOTEL 16500 SOUTHCENTER PY M13-002 City ofkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 6437300010 Address: 16500 SOUTHCENTER PY TUKW Project Name: DOUBLE TREE HOTEL Permit Number: M13-002 Issue Date: 01/18/2013 Permit Expires On: 07/17/2013 Owner: Name: CHA SOUTHCENTER LLC Address: 16500 SOUTHCENTER PICWY , SEATTLE WA 98188 Contact Person: Name: CHRIS LEE Address: 717 DETROIT AV SW , SEATTLE WA 98106 Email: CHRIS.LEE@MACMILLER.COM Contractor: Name: MACDONALD/MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA 98106 Contractor License No: MACDOFS980RU Phone: 206-768-4266 Phone: 206-768-4180 Expiration Date: 01/03/2015 DESCRIPTION OF WORK: REPLACE (1) 3 -TON ROOFTOP A/C UNIT WITH LIKE FOR LIKE REPLACEMENT UNIT. Value of Mechanical: $8,392.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $293.81 International Mechanical Code Edition: 2009 Date: \—Ag-'` I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Print Name: 19 Date: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 114 7 /1/.f fl.:..... _&. Al , 0 901, �} PERMIT CONDITIONS Permit No. M13-002 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. dor: IMC: -4/1f1 M13 -M7 Printari• 01 -1R -7O11 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be•accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 643730-0020 Site Address: 16500 Southcenter Pkwy, Tukwila, WA 98188 Suite Number: 100 Floor: 1 Tenant Name: Double Tree Hotel New Tenant: ❑ Yes ❑✓ ..No PROPERTY OWNER Name: Chris Lee Name: CHA Southcenter LLC 551777 City: Seattle State: WA Zip: 98106 Address: 16500 Southcenter Pkwy Email: chris.lee@macmiller.com City: Seattle State: WA Zip: 98188 CONTACT, PERSON - person receiving all project communication Name: Chris Lee Address: 7717 Detroit Ave SW City: Seattle State: WA Zip: 98106 Phone: (206) 768-4266 Fax: Email: chris.lee@macmiller.com MECHANICAL CONTRACTOR INFORMATION Company Name: MacDonald -Miller Facility Solutions Address: 7717 Detroit Ave SW City: Seattle State: WA Zip: 98106 Phone: (206) 768-4278 Fax: Contr Reg No.: MACDOFS980RU Exp Date: 12/31/2013 Tukwila Business License No.: BUS -0100868 Valuation of project (contractor's bid price): $ 8,392 Describe the scope of work in detail: Replace (1) 3 -ton rooftop A/C unit with like -for -like replacement unit. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas 0 Other: H:lApplications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docu Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Fumace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfin 1 Unit Type Qty Air handling unit >10,000 cfin Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Print Name: Chris Lee Mailing Address: 7717 Detroit Ave SW H:\Applicatiom\Formt-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.doca Revised: August 2011 bb Date: 01/02/2013 Day Telephone: (206) 768-4266 Seattle WA 98106 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 6437300010 Permit Number: M13-002 Address: 16500 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 01/07/2013 Applicant: DOUBLE TREE HOTEL Issue Date: Receipt No.: R13-00067 Payment Amount: $293.81 Initials: WER Payment Date: 01/07/2013 01:29 PM User ID: 1655 Balance: $0.00 Payee: MACDONALD MILLER FACILITY SOLUTIONS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3520 293.81 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 235.05 000.345.830 58.76 Total: $293.81 /1A f17 nn.03 :.:'.INSPECTION RECORD Retain a copy with permit •INSPECTION NO. - - PERMIT NO. CITY SOF TUKWILA BUILDING DIVISION 6300-Southcenter Blvd.,4100, Tukwila. WA 98188 r_ (206) 431-3670 ,Permit,Inspection Request Line (206) 431-2451 Project: Type of Inspection: Ake_p �, Address:' 1 (.51) 0 , P-ANrK))i Dated• tit_..14./ 0,--\.) U(0 Special Instructions: eilo _ .. n ,Date Wanted:. ...a.m.. /-`2.3343 p.m. Requester: Phon No:% ���4P'3,1i�0t(s. Approved per:applicable codes. COMMENTS: Corrections required prior to approval. f riukr-rtwo�� �}. 1 \ 3 Inspector: 13 n REINSPECTION FEE. REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. • i KIA CO FILE COPY 1802 W Lake Sammamish PKWY SE Bellevue, WA 98008 Phone: 425-644-6400 Cell: 425-351-5999 DOUBLE TREE HOTEL MECHANICAL UNIT SUPPORT RTU -13 16500 SOUTHCENTER PARKWAY TUKWILA, WASHINGTON 98188 FOR MacDonald -Miller Facilities Solutions STRUCTURAL CALCULATIONS DECEMBER 28, 2012 JOB NO: 156-1217 1 EXPIRES Il•-•Ti7-Zol3 I M13O0Z REVIEWED FOR CODE COMPLIANCE APPROVED !JAN 18 Imp City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 7 2013 PERMIT CENTER .0 V CD 0 8 3o,d PARTIAL ROOF FRAMING PLAN NOTES: 1) CONTRACTOR TO VERIFY ALL SIZES, DIMENSIONS, AND LOCATIONS AT FIELD. 2) CONTRACTOR TO VERIFY ALL EXISTING ROOF FRAMING MEMBER SIZES. 3) CONTRACTOR TO VERIFY MECHANICAL UNIT SIZE, WEIGHT AND LOCATIONS. Project/Subject )2 By Sheet No."1/1/4... Date Job No. J L L 65(); jc}17 L J'L a 4 Project/Subject / 7 I By Date Jz�l � Sheet No. %14 - Job No. ROOF LOADS: DEAD LOAD: B.U. ROOFING METAL DECKING ROOFJOISTS SPRINKLER INSULATION PURLIN CEILING. MISC. MECH. SU&TOTAL IVE LOAD: SNOW TOTAL LOAD; 2.5 PS 2. 2 1.5 1.5. 0 2. 3.5' 15 PS 25 PSF 40 PSF. MECHANICAL UNIT DATA: RTU -13 ' 558 lbs (Unit) + 138 lbs (Adap. Curb) + 60 tbs (Exist. Curb) 0 a te BY gate Sheet No. Job No. 050.0" ',e if ----; 3z fz.,4)-io Gd 3 0 ,G; ✓�`. ; 4-) 32- 47L L , Z,76 J'G-- �/yfi,✓ s �o' 9'../P24 3jy )z jG,/ 756 .kf j/%20.e.-)L )000� B !o 4t2f /IPJ%aG✓, 4-)3sL ��/g =J£ 2 > all g O v 4 Project/Subject 6��G By A / // �C 1 Date )Z�ITi Sheet hiiver Job No. /�—))> LATERAL DESIGN(IB.0 WIND. ASIC WINDSPEED EXP. "B" Iw= 1.0 Kdi= 0.5 Kz 7 0.7 Kzt= 1.0 Gf = 0.85 2009 85 qz = 0.00256 7c KZ x Kzt x Kd x V^2 x I ... . ................. .... ... qz = 11.7 PSF ASCE 7-05) MPH FIG, 6-1, ASCE 7-05) (TABLE 6-4, ASCE 7-05) UPTO30' (FIGURE 6-4, ASCE 7-05) (GUST FACTOR) (EQ. 6-15) 1.3 (FIG. 6-21; ASCE 7-05 FOR MECHANICAL UNIT) F zxGfxCfxAf 12.88 Af UNIT LENGTH (L) UNITWIDTH (W) UNIT HIGHT (H) = SHORT DIRECTION: F wind = LONG DIRECTION F wind = 5.8 .3.7 3.0 224 143 FT FT FT Ibs Ibs (EQ 6-28) 0 ,env- j3 By Date) z-/) sneer 1i- Joe We MCE Ground Motion - Conterminous 48 States Zip Code - 98188 Central Latitude = 47.447736 Central Longitude = -122.273462 Period MCE Sa (sec) (%g) 0.2 133.7 MCE Value of Ss, Site Class B 1.0 046.0 MCE Value of S1, Site Class B Spectral Parameters for Site Class D 0.2 133.7 Sa = FaSs, Fa = 1.00 1.0 070.8 Sa = FvS 1, Fv = 1.54 Spectrum for Site Class D Period MCE Sa (sec) (%g) 0.000 053.5 T = 0.0, Sa = 0.4FaSs 0.106 133.7 T = To, Sa = FaSs 0.200 133.7 T = 0.2, Sa = FaSs 0.529 133.7 T = Ts, Sa = FaSs 0.600 118.0 0.700 101.1 0.800 088.5 0.900 078.6 1.000 070.8 T = 1.0, Sa = FvS 1 1.100 064.3 1.200 059.0 1.300 054.4 1.400 050.6 1.500 047.2 1.600 044.2 1.700 041.6 1.800 039.3 1.900 037.3 2.000 035.4 • SEISMIC (2009 :IBC) ZIP CODE: 98188 LATITUDE.= 47.44 LONGITUDE _ -122.27 Ss . S1 SITE CLASS "C" SDC =.Q:. Fa 1.54 Sms=•Fax$s •Sml FvxS1 Sds = 2/3 Sms = $d1=2/3Sm1= (0.4 Ap.Sds.Wp/(Rp/Ep)) Ap Ip Rp = Sds 2.5 . 1 6 0.89 1.337 g 0.71.g 0.89 g 0.47 g (1 + 2 ZJH) (EQ. 13.3-1) O v 4 By Date )Z1 Z - Job No. Fp (MAX) = 1 6 Sds.Ip.Wp = Fp (MIN) = 0 3Sds.Ip.Wp = Fp (ASD) =. CHECK Fp/4.4= 796 lbs > Fp O.K. 149 lbs < Fp: O.K. 178 lbs GOVERNS IN SHORT DIRECTION) (WIND UNIT. STABILITY: SHORT DIRECTION:. F{WIND)=- ' :224. lbs: M (O.T.) = 336 Ibs-ft M(R). = . 1032.Ibsft 0.6 M (R)= 619 lbs -ft > M (O.T.) NO UPLIFT USING: MINIMUM (3)-#12 SCREWS EACH SIDE:OF THE UNIT / CURB . F{wind) /#12 SCREW= 37 lbs-O.K. •I Projeal5ubjea 1 Wil/—l_3 Date Tial � sneer Nom Job No. 1 --iv, APPENDIX RTAi-t31 2 end RTU -10 replaced during previous Job o REPLACE A/C URN AND INSTAL ADAPTER CURB. OLSCOMECT ARO RECONNECT C/3 ND ELECTRICAL. SEE STRUCTURAL CALCULATIONS FOR NOUNTNO-DEEMS 1=3/r- =El I:a03Na 0 CAS METER Ung . identified al Ac -r on Id drawing but a now called RTU 3. New Job Involves replacing RTU 13 0 Q) -CD t (8) 1110•-r'-0' 0-6 g 14 I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I 1 1 1 I z 0 WW Z 0 Lu O' UW 0 a.te z o W'hWW- x d 0 w CC M J B CI < r m' r m S O 1-o z 1! Oi z a.m WI MOM C LEE 12-26-12 a161= Ira un nom B CEZON as ewe are R VILL4NUEVA aw+o NNem D-1214-7327183-00 NW Maio TM2.02 • -Doubletree Tukwila RTU #13 Replace - MM Unit Dimensions - 3-10 Ton R410A PKGD Unitary GaslElectric Rooftop Item: Al Qty: 1 Tag(s): 3 Ton EVAPORATOR SECTION ACCESS PANEL TOP PANEL December 13, 2012 CONDENSER FAN CONDENSATE DRAIN (ALT) 3/4"-14 NPT DIA HOLE 41/4" THROUGH THE BASE CONDENSATE 23 9/16" 421/4 231!2' ONDENSER COIL UNIT CONTROL WIRE 7/8" DIA. HOLE SERVICE GAUGE PORT ACCESS 1 3/8" DIA HOLE NIT POWER WIRE ONTROL AND COMPRESSOR ACCESS PANEL 1/2" NPT GAS CONNECTION NOTES: 1. THRU -THE -BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2. VERIFY WEIGHT, CONNECTION, AND ALL DIMENSION WITH 4 3/16" INSTALLER DOCUMENTS BEFORE INSTALLATION r RETURN 24" 15 IIT PLAN VIEW UNIT 9 1/4" 14" DIMENSION DRAWING CONDENSATE i [73-18- 231/4" 43/4 8 7/8" 13 1/4" - 3 3/16" 69 7/8" 38 t 7 a RETURN SUPPLY 143/4" 0 1 0 J� -- CONDENSATE i [73-18- 231/4" 43/4 8 7/8" 13 1/4" - 3 3/16" 69 7/8" 38 PACKAGED GAS / ELECTRICAL DIMENSION DRAWING HORIZONTAL AIR FLOW FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Installed by Others Page '7 of 15 t a /4" 1 201/4" 4 0 9 518" 5 518" 0 41/4"—"- 5 9/18" 7 5/8" 441/4" PACKAGED GAS / ELECTRICAL DIMENSION DRAWING HORIZONTAL AIR FLOW FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Installed by Others Page '7 of 15 Doubletree Tukwila RTU #13 Replace - MM Weight, Clearance & Rigging Diagram - 3-10 Ton R410A PKGD Unitary GaslElectric Rooftop Item: Al Qty: 1 Tag(s): 3 Ton PACKAGED GAS / ELECTRICAL CORNER WEIGHT December 13, 2012 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 26.0 Ib MOTORIZED OUTSIDE AIR DAMPER MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR BELT DRIVE MOTOR POWER EXHAUST THROUGHT THE BASE ELECTRICAL (FIOPS) UNIT MOUNTED CIRCUIT BREAKER (FIOPS) UNIT MOUNTED DISCONNECT (FIOPS) POWERED CONVENIENCE OUTLET (FIOPS) HINGED DOORS (FIOPS) HAIL GUARD SMOKE DETECTOR, SUPPLY / RETURN NOVAR CONTROL STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET 165.0 Ib © 95.0 ib (E) LENGHT (F) WIDTH 607.Olb 532.Olb 0 137.0 lb 0 134.OIb 31" 19" NOTE: 1. CORNER WEIGHTS ARE GIVEN FOR INFORMATION ONLY. 2. TO ESTIMATE SHIPPING WEIGHT ADD 5 LBS TO NET WEIGHT. 3. BASIC UNIT WEIGHT DOES NOT INCLUDE ACCESSORY WEIGHT. TO OBTAIN TOTAL WEIGHT, ADD ACCESSORY NET WEIGHT TO BASIC UNIT WEIGHT. 4. WEIGHTS FOR OPTIONS NOT LISTED ARE >5 LBS. PACKAGED GAS / ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Installed by Others Dqubletree Tukwila RTU #13 Replace - MM Weight, Clearance & Rigging Diagram - 3-10 Ton R410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): 3 Ton CLEARANCE 38" CLEARANCE 48" DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" ROOF OPENING UNIT OUTLINE CLEARANCE 36" PACKAGED GAS / ELECTRIC CLEARANCE 40" 68 3/16" 37" December 13, 2012 CLEARANCE FROM TOP OF UNIT 77' 441/2" PACKAGED GAS / ELECTRIC DOWNFLOW TYPICAL ROOF OPENING FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Installed by Others Page 11 of 15 O E r CO do Ce 0 M � a F of a+ a as ni m, 03 .0o 7 a ‘a, 41711er 24 11/16' 16 5116' +1 UrLt11YYm 410 mur/wt m POI Mill wt MI•t1111 Atte: Tag: Approval: 261 16' 19 S'8` r L INSULATED COVER 653/16^ EXISTING CURB LAYOUT 379'16' 25 7116' —�- 21 13/16' 011/10' 25 18" 28 3'4^ 1 SUPPLY 7 11$' RETURN 23 M4TERLALILI.18ga.GALVANIZED STEEL 3 GASKET PAOViDEA WITH CURB 4. INSULATION 1^ 1 112 LB DENSITY 427/8' AP+151ON5 Rlv. DESCAIPI!ON DM! APPCOYED 6/ 21/20nd CURB SHOWN IS CDI STANDARD CONFIGURATION ON RESERVES THE RIGHT TO CHANGE LAYOUT WITHOUT NOT*FRCATION. F CURB IS NEEDED W A DIFFERENT CONFIGURATION COI MUST BE NOTIFIED PRN3R TO PLACING AN ORDER. YCKrr CADMAN UNDID VERP! SUPPLY Ab RENR11OPEMM( NDIE ANY CRINGES C119.1. WIN ANY 121E611016 AY DAB( IP DRAWING B OK AE 1E 13l,tly :et= • denim Yuman :Ip117L 2K163,11 01 HA • "l 1-3690-3100 QUOTE #: 4T6m TYLIIIIST NW CDIWar66216 1.30313.31m +� l 1;;;;;77-113 rein 1 or 3 Equipment Submittal PE U. CO. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-002 DATE: 01-07-13 PROJECT NAME: DOUBLE TREE HOTEL SITE ADDRESS: 16500 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: ocfof Building Division Public Works ❑ Mt. /mac, t-1.6%43 Fire Prevention II Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: 7L. Incomplete DUE DATE: 01-08-13 Not Applicable Permit Center Use ;Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 02-05-13 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople titer Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MACDONALD/MILLER FAC SOL INC UBI No. 602254260 Phone 2067684180 Status Active Address Po Box 47983 License No. MACDOFS980RU Suite/Apt. License Type Construction Contractor City Seattle Effective Date 12/31/2002 State WA Expiration Date 1/3/2015 Zip 98106 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVCOI'988RC DIVCO INCORPORATION Construction Contractor General Unused 12/3/2002 11/7/2014 Active LINFOAR980QG LINFORD AIR & REFRIGERTN INC Construction Contractor General Unused 11/7/2002 11/7/2004 Archived ENCOMPASS ENCOMMS984CA MECHANICAL SERVICES Construction Contractor General Unused 2/1/2002 2/1/2004 Archived MACDOMR026RU MACDONALD MILLER RSDNTL INC Construction Contractor General Unused 12/31/1998 12/31/2001 Archived DIVC01'031L4 DIVCO INC Construction Contractor General Unused 6/24/1997 8/1/2003 Archived MACDOMR076OPMACDNALDMILLER RESIDENTIAL Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDONALD MILLER MACDOM*248J9 CO Construction Contractor General Unused 4/29/1976 2/1/2002 Archived Business Owner Information Name Role Effective Date Expiration Date GOUGH, DAVID ANTHONY Director 12/29/2010 HOEL, STEPHANIE W Member 05/14/2010 SIMONDS, DERRICK R President 05/14/2010 WEBSTER, MARK E Vice President 05/14/2010 TURLEY, DOUGLAS Chief Executive Officer 02/13/2008 01/04/2011 TURLEY, DOUGLAS Chief Operating Officer 02/13/2008 01/04/2011 SIGMUND, FREDRIC President 12/31/2002 01/04/2011 HACK, RICHARD Secretary 02/13/2008 01/04/2011 KOPET, TYLER Treasurer 12/31/2002 01/04/2011 LOVELY, STEVE C Vice President 12/31/2002 01/04/2011 Bond Information Bond Company Name LIBERTY MUTUAL INS CO Bond 1 Page 1 of 2 Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 023006951 12/11/2002 Until Cancelled $12,000.00 12/31/2002 Assignment of Savings Information No records found for the previous 6 year period httns //fortress_wa.vov/lni/bbin/Print.asnx 01/18/2013 r- 0 0 N N M s- 0 0 0 0 0 ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD-MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE-UP AIR NOMINAL OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP TSTAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START/STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER ' DAMPER SCHE�UL� :' SYMBOL DESCRIPTION -POWERED NOTES SYMBOL DESCRIPTION -NON POWERED NOTES 1 1/2 HOUR FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL OR 1,2 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL FSD- 1 1 HORIZONTAL, 3-V BLADE,LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK FD -1 ® OR HORIZONTAL ,165° F FUSABLE LINK, BLADE IN AIR STREAM, GREENHECK DFD 150 TYPE A OR EQUAL. FSD 212 OR EQUAL. 1 1/2 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL 1 1/2 HOUR FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL 1,2 FD -2 ® OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR FSD-2 .0.OR HORIZONTAL, AIRFOIL BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, STREAM, GREENHECK DFD 150 TYPE B OR EQUAL. GREENHECK FSD 312 OR EQUAL. 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL FD -3 © OR HORIZONTAL, 165° F FUSABLE LINK, BLADE IN AIR 3 HOUR FIRE/SMOKE DAMPER: LOW VELOCITY, VERTICAL OR 1,2 STREAM, GREENHECK DFD 350 TYPE A OR EQUAL. FSD-3 O HORIZONTAL, 3V BLADE, LEAKAGE CLASS 2, 120V ACTUATOR, 2 ,,-t++t+ POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK 3 HOUR DYNAMIC FIRE DAMPER: CURTAIN STYLE, VERTICAL + + + y FSD 231 OR EQUAL. FD -4 © OR HORIZONTAL, 165° F FUSABLE LINK, BLADE OUT OF AIR STREAM, GREENHECK DFD 350 TYPE B OR EQUAL. 3 HOUR FIRE/SMOKE DAMPER: MEDIUM VELOCITY, VERTICAL 1,2 FSD-4 O OR HORIZONTAL, AIR FOLD BLADE, LEAKAGE CLASS 1, 120V ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK GREENHECK FSD 311 OR EQUAL 1 1/2 HOUR DYNAMIC FIRE DAMPER: LOW VELOCITY, NARROWLINE, VERTICAL FOR INSTALLATION BETWEEN 2 FD -5 ® TRANSFER GRILLES IN A WALL ASSEMBLY, 165° F FUSABLE LINK, GREENHECK DFD -110 OR EQUAL. 1 1/2 HOUR TUNNEL CORRIDOR FIRE/SMOKE DAMPER: 1,2 FSD-5 1 LOW VELOCITY, 3V BLADE, LEAKAGE CLASS 2, 120V FD -6 O CEILING RADIATION DAMPER: GREENHECK CRD -2 OR EQUAL. ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, GREENHECK CFSD 212-1 OR EQUAL. BDD BACKDRAFT DAMPER: GREENHECK WD 330 (VERT) OR WD -100 (HORIZONTAL) OR EQUAL. 1 1/2 HOUR OUT OF WALL FIRE/SMOKE DAMPER: LOW 1,2 FSD-6 1 VELOCITY, VERTICAL , 3V BLADE, LEAKAGE CLASS 2, 120V BAR . RELIEF DAMPER: (.05 OPNG PRESSURE SHOWN) ,,BAROMETRIC ACTUATOR, 2 POSITION, FAIL CLOSED, 165° F FUSABLE LINK, RUSKIN CBD2. NO SUBSTITUTE ALLOWED. GREENHECK OF SD 212 OR EQUAL. VOLUME DAMPER: SHOP FABRICATED, W/LOCKING QUADRANT. SD -1 OS SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. 1,2 SD -2 O SMOKE DAMPER: GREENHECK SMD 202 OR EQUAL. 1,2 MOTORIZED CONTROL DAMPER -LOW VELOCITY GREENHECK 3 MD -1.0. D-1 M VCD-23 OR EQUAL, MD -2 O MOTORIZED CONTROL DAMPER: MEDIUM VELOCITY AIRFOIL 4 BLADES GREENHECK VCD-33 OR EQUAL. SCD-1<>SMOKE CONTROL MOTORIZED DAMPER: LOW VELOCITY 1,2 GREENHECK SMD 202 OR EQUAL. SCD -2 <> SMOKE CONTROL MOTORIZED DAMPER: MEDIUM VELOCITY SCD -2 SC AIRFOIL BLADE, GREENHECK SMD 301 OR EQUAL, 1,2 NOTES: 1. ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR 2. INTERLOCK OF SMOKE DAMPER TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR 3. CONTROL FROM LOCAL DETECTOR 4. CONTROL FROM DUCT DETECTOR 5. OPEN/CLOSED POSITION INDICATOR 6. DAMPER FAILS OPEN 7. DAMPER FAILS CLOSED DESCRIPTION BARE SHEETMETAL SOUNDLINE SHEETMETAL (1" LINING) SHEETMETAL WRAPPED W/ INSULATION (2") SYMBOL 14x12 14x12SL 14x12W DESCRIPTION ROUND SHEETMETAL WRAPPED W/ INSULATION (2") CLEANROOM QUALITY DUCTWORK BARE FLAT OVAL SHEETMETAL 14x120 BARE ROUND SHEETMETAL 120 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2") 14x120W EXPOSED QUALITY SHEETMETAL 14x 12Q DUCTBOARD (1" FIBERGLASS) 14x12DB EXAMPLE OF NEW 14x12 EXAMPLE OF NOT IN CONTRACT (NIC) 14x12 EXAMPLE OF DEMO FLEX DUCT EXAMPLE OF EXISTING 1 4X 12 FLEX CONNECTOR 3 f UNIT NO. MFG & MODEL NO. NOM TONS GAS HEAT MBH INPUT OUTPUT CFM ESP FAN HP OSA CFM SEER ELECTRICAL VOLT/PH MCA WT LBS dB NOTES RTU -12 TRANE YSC090E4EMA018Y 7.5 150 120 3000 0.5 750 11.2 460/3 19.5 1142 89 EXISTING TRANC CrI IA 304 I IC RTU -13 TRANE YSC036E4RMA 3 3 80 +268 468/3 598 64 1200 0.75 300 13 460/3 11.7 696 81 DEMO NEW, 1-4 RTU -14 TRANE YSC036E4EMA0047 3 80 64 1200 0.5 300 13 460/3 10.1 740 81 EXISTING NOTES: 1. USE EXISTING POWER WIRING. DISCONNECT AND RECONNECT ELECTRICAL SERVICE AND NEW DISCONNECT SWITCH BY M -M. 2. FACTORY 0-100% ECONOMIZER WITH BAROMETRIC RELIEF. 3. R-410 REFRIGERANT. 4. SUMMIT CONTROL CARD, SENSORS, INTEGRATION WITH EXISTING BUILDING DDC SYSTEM AND PROGRAMMING BY M -M. 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2009 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2009 IMC AND WITH CURRENT SMACNA STANDARDS. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2009 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.) 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2009 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2009 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2009 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18". 11. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. WITHIN 90 DAYS AFTER THE DATE OF SYSTEMACCEPTANCE,ECO D DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD 12. AT RECORD A DRAWINGS SHALL INCLUDE S INIMUM HE C O ORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE AM T LO ATI NAND PERF Q DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 13. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 14. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416. 15. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED `"PITH THE OWNER 16. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM/S.F. GRAVITY DAMPERS: 20 CFM/S.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 17. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY THE WSEC. TITLE PROJECT ENGINEER ACCOUNT MANAGER SHEET METAL FOREMAN SHEET METAL FOREMAN AIR BALANCE FOREMAN FITTING FOREMAN ELECTRICAL SUPERINTENDENT FACILITIES DIRECTOR NAME CHRIS LEE ERRYN EDRINGTON CHRIS HOLLINGSWORTH BILL BRITTAIN RON LANDBERG JASON ZEMBRYCKI ED ADAMS JACK O'CONNOR COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206-768-4266 253-798-5080 206-407-2620 206-407-2652 206-571-2661 206-768-3860 206-768-3826 206-293-5516 EMAIL CHRIS.LEE@MACMI LLER.COM ERRYN.EDRINGTON@MACMILLER.COM CH RIS.HOLLINGSWORTH@MACM ILLER.COM BILLBRITTAIN@MACMILLER.COM RON.LANDBERG@MACMILLER.COM JASON.ZEMBRYCKI@MACMILLER.COM ED.ADAMS@MACMILLER.COM REPLACE (1) PACKAGED GAS HEAT ROOFTOP UNITS WITH LIKE -FOR -LIKE TONNAGE REPLACEMENT. INSTALL (1) CURB ADAPTERS. DISCONNECT AND RECONNECT POWER WIRING AND GAS SERVICE. PROVIDE AND INSTALL SUMMIT CONTROL CARDS, SENSORS, PROGRAMMING AND INTERGRATION WITH EXISTING BUILDING DDC SYSTEM. AIR BALANCE. NAME TITLE NAME TITLE TM0.01 SCHEDULES - HVAC TM0.01S SITE MAP - HVAC TM2.02 ROOF PLAN - HVAC TM3.01 ELEVATIONS - HVAC APN# 6437300020 LEGAL DESCRIPTION: CHA SOUTHCENTER LLC S"PA'ATE PERMIT l QUIRED FOR: D Mechanical tactical reAlumbing Piping City of Tukwila DUif-WHIG DIVISION PROJECT LOCATION REVISIONS No chances shall be made to the scope of t^'nr'c without prior approval of Ir c Ila Building Division - NOTE: I,aw;sicns will require a new plan submittal £nJ may include additional plan review fees. VICINITY MAP NO SCALE REVIEWED FOR CODE COMPLIANCE APPROVED JAN 18 'mil per-LOC City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 7 2013 PERMIT CENTER M13002 FILE COPY tiaRio. lit 4&4°.W Z Pr r7vin approval is subist to mots and omissions. k:-.- :..-t of c:o 3irucfion documents does not authc ?a tii:j^{' n ,_ any adopted code or ordinance. Receipt of Lpproved c ' id is „4, loti a 1# 1, Date: (7/ ( 2 - City Of Tukwila BUILDING DIVISION W •TS 0 a 0 _O r C) c)C0 CC? ti 7:7< (0 "0-,.. 1� L..) CO i� N --.5 U) LL 6 C 0 ', = do'" Oi a a� , '- Quo - 0 O < D 6 L.L. a� 0 Tz tid www.macmiller.com WA Lic No: MACDOFS980RU I I I 1 1 1 1 1 1 1 1 N1 N Z -J ww w O 0 <W� �W� LU w co °N:2 1.11 Www C") Ji< rm1� D°J F. ENGINEER: C LEE CHECKED BY: B GEZON (0 REVISIONS: W F- REVISIONS: 0 0 F- U z 0 U 0 LL 0 w LAST REVISED: 12-31-12 DATE PLOTTED: 12-31-12 CAD: ISSUE DATE: R VILLANUEVA 12-31-12 DRAWING NUMBER: D-1214- 7327183-00 SHEET NUMBER: TM0.01 STRANDER BLVD 1 I ,,-t++t+ 1 SOUTHCENTER PKWY + + + y +++t+ a S 168TH ST VICINITY MAP NO SCALE REVIEWED FOR CODE COMPLIANCE APPROVED JAN 18 'mil per-LOC City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 7 2013 PERMIT CENTER M13002 FILE COPY tiaRio. lit 4&4°.W Z Pr r7vin approval is subist to mots and omissions. k:-.- :..-t of c:o 3irucfion documents does not authc ?a tii:j^{' n ,_ any adopted code or ordinance. Receipt of Lpproved c ' id is „4, loti a 1# 1, Date: (7/ ( 2 - City Of Tukwila BUILDING DIVISION W •TS 0 a 0 _O r C) c)C0 CC? ti 7:7< (0 "0-,.. 1� L..) CO i� N --.5 U) LL 6 C 0 ', = do'" Oi a a� , '- Quo - 0 O < D 6 L.L. a� 0 Tz tid www.macmiller.com WA Lic No: MACDOFS980RU I I I 1 1 1 1 1 1 1 1 N1 N Z -J ww w O 0 <W� �W� LU w co °N:2 1.11 Www C") Ji< rm1� D°J F. ENGINEER: C LEE CHECKED BY: B GEZON (0 REVISIONS: W F- REVISIONS: 0 0 F- U z 0 U 0 LL 0 w LAST REVISED: 12-31-12 DATE PLOTTED: 12-31-12 CAD: ISSUE DATE: R VILLANUEVA 12-31-12 DRAWING NUMBER: D-1214- 7327183-00 SHEET NUMBER: TM0.01 1') J:\732\7183 DoubleTree Tukwila RTU Monday, December 31, 2012 7:37:42 a n J' rTh / / J J J JJ �ROJFCT LOCATO\ I li 0 RTU -1 HV— 1 EF— 6 EF— FM -1 RTU-14 l 1 0 RTU -3 RTU -12 EF— 5 1" RTU -5 RTU -14 EF -8 AA/C UNIT AND [_y,j/f—REPLCE INSTALL ADAPTER CURB, DISCONNECT AND RECONNECT GAS AND ELECTRICAL, SEE STRUCTURAL CALCULATIONS FOR MOUNTING DETAILS EF -5 RTU -13 2" FM -2 / EF - 1 Q 2" 2 3" ©— r 340 HV -1 11 EF -12 I 0 HV -2 0 EF -8 — GAS METER 77. J C±) c REVIEWED FOR CODE COMPLIANCE APPROVED JAN 18 'ni City of Tukwila) BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 7 2013 PERMIT CENTER 1/16" = 1'—O„ _cs O 0 ctsU LL 1 1 1 1 1 1 1 1 1 1 1 1NI i cV zJ W W 0 0 Jw �: WY Q W w co Z f www M J=a : D°J I—O8Y Q02 )12 ENGINEER: C LEE CHECKED BY: B GEZON Lu 0 REVISIONS: W 0 REVISIONS: z 0 0 z 0 U OC 0 LL. 0 W D u) LAST REVISED: 12-31-12 DATE PLOTTED: 12-31-12 CAD: ISSUE DATE: R VILLANUEVA 12-31-12 DRAWING NUMBER: D-1214-7327183-00 SHEET NUMBER: TM2.02 J:\732\7183 DoubleTree Tukwila RTU 13 EE\00\2 RTU -13 EAST BUILDING ELEVATION SCALE: 1/16" = 1'-0" / LOWER ROOF RTU -13 0) GRADE 0 CV GRADE SOUTH BUILDING ELEVATION SCALE: 1/16" = 1'-0" z COC oti ti COco rn� < o N E cts N coU ALL O co C 0 • Q co • O O CO L N ❑ a) O ti co rn v) LL 00 2 ciz .U_ REVIEWED FOR CODE COMPLIANCE APPROVED JAN 18 'nil City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 0 7 2013 PERMIT CENTER 1/16" = 1'-0" I I l< REVISIONS: REVISIONS: ENGINEER: C LEE CHECKED BY: B GEZON LAST REVISED: 12-31-12 DATE PLOTTED: 12-31-12 CAD: ISSUE DATE: R VILLANUEVA 12-31-12 DRAWING NUMBER: D-1214-7327183-00 / TM3.01 SHEET NUMBER: