Loading...
HomeMy WebLinkAboutPermit M13-003 - OCHOA RESIDENCE - ALTERATIONOCHOA RESIDENCE 11863 44 AV S CANCELLED 04-24-13 M13-003 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 3347400486 Address: 11863 44 AV S TUKW Project Name: OCHOA RESIDENCE Permit Number: M13-003 Issue Date: 01/15/2013 Permit Expires On: 07/14/2013 Owner: Name: OCHOA JUANA Address: 11863 44TH AVE S , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Email: SHARYN.PARKER@KINGCOUNTY.GOV Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST , PHOENIX AZ 85040 Contractor License No: GGSPEGS919RT Phone: 206 296-7437 Phone: 480-921-4079 Expiration Date: 12/31/2013 DESCRIPTION OF WORK: FRESH AIR SERVICING FOR SOUND REMEDIATION WORK. Value of Mechanical: $1,316.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Fees Collected: $167.70 International Mechanical Code Edition: 2009 Permit Center Authorized Signature: Date: I hereby certify that I have read and ex• ed this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie wit , whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this pe Signature: Print Name: 0 Lekort) This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: 1—/S -(3 • • PERMIT CONDITIONS Permit No. M13-003 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Manufacturers installation instructions shall be available on the job site at the time of inspection. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 7: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 8: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. dor.• IM( -4/1 O Mmfttn Printed• f11-15-2(11 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. �'-01 Project No. Date Application Accepted: V. t )1 t 13 Date Application xpires: +� (or otrice use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 11863 44th Ave S. Tenant Name: Juana Ochoa King Co Assessor's Tax No.: 3347400486 Suite Number: Floor: PROPERTY OWNER Name: Sharyyn Parker, Program Manager Name: Juana Ochoa City: Seattle State: WA Zip: 98108 Address: 11863 44th Ave S. Email: Sharyn.Parker@kingcounty.gov City: Tukwila State: WA Zip: 98178 CONTACT PERSON — person receiving all project compolicatton �. Name: Sharyyn Parker, Program Manager Address: 7277 Permieter Road South City: Seattle State: WA Zip: 98108 Phone: (206)296-7437 Fax: (206)296-7315 Email: Sharyn.Parker@kingcounty.gov New Tenant: ❑ Yes J ..No MECO LAICAL. CONTRACTOR INFORMATION Company Name: TBD , Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 1316.00 Describe the scope of work in detail: Fresh air servicing for sound remediation work. Use: Residential: New ❑ Replacement 0 Commercial: New ❑ Replacement 0 Fuel Tvpe: Electric 0 Gas ❑ Other: H:Wpplications\Potms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9.11.docc Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT-APPLICATiION NOTE �...., Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW1V.E Signature: e O • . • ZED AGENT: Print Name: Jesse Holgate Mailing Address: 4000 Delridge Way SW. #200 H:\Applications\Fonns-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9.11.docx Revised: August 2011 bh Date: Day Telephone: (206)624-2777 Seattle WA 98106 City State Zip Page 2 of 2 City or 'Tukwilar Department of Comnwnity Development 6300 Southcerter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: htrp:/tvww.ci.iukwila.wa.us SET RECEIPT RECEIPT NO: R13-00124 Initials: JEM Payment Date: 01/09/2013 User ID: 1165 Total Payment: 13,045.45 Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE) SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT SET TRANSACTIONS: Set Member Amount D13-004 1,018.34 D13-005 1,239.61 D13-006 1,313.36 D13-007 779.67 D13-008 1,116.68 D13-009 1,141.27 D13-010 1,313.36 D13-011 1,092.10 D13-012 1,239.61 D13-013 1,092.10 M13-003 167.70 M13-004 186.50 M13-005 177.10 M13-006 167.70 M13-007 177.10 M13-008 177.10 M13-009 124.25 M13-010 177.10 M13-011 167.70 M13-012 177.10 TOTAL: 3 ; oft" TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,045.45 TOTAL: 13,045.45 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 6,849.15 CityTukwilar� Departm . of Community Development 6300 Southcerter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: htgi:/4w w.ci.tuktivila.wa.us STATE BUILDING SURCHARGE 640.237.114 45.00 TOTAL: 13, 045.45 August 7, 2013 City of Tukwila Jinz Haggerton, Mayor Department of Community Development Jack Pace, Director KC International Airport ATTN: Pamela Keuhl AIR TR -0200, 2nd Floor Terminal 7277 Perimeter Rd S Seattle, WA 98108-0245 RE: Refund for Permit Number M13-003 Ochoa Residence —11863 44 Av S Dear Ms. Keuhl, This check in the amount of $33.54 is for the balance of the refund originally mailed to you on May 21, 2013. Unfortunately there was a mathematical error in the original refund. Please accept my apologies for the delay in getting this full refund to you. AFA4Pcig shall ician File: Permit No. M13-003 Encl: Check No. 364042 63M .Cnuthrontor Rnulovard gni/49 inn() • Mk -wilt] Wa.chinvtnn 9R1RR • Phnne 206-431-3670 • Far 206-431-3665 TO: FROM: DATE: SUBJECT: MEMORANDUM Laurie Anderson Brenda Holt v July 22, 2013 Ochoa Residence Permit Number M13-003 Please draw a check in the amount of $33.54 (thirty-three dollars and fifty-four cents) to be payable to King County International Airport. The address to reference on the check should include the following: King County International Airport/Boeing Field ATTN: Pamela Keuhl AIR TR -0200 7277 Perimeter Rd S 2nd Floor Terminal Seattle, WA 98108-0245 The original request for refund was sent to the Finance Department on May 1, 2013. Since that date a phone call was received wherein it was discovered that while the Building Official granted an eighty percent refund of the Building Permit (D13-004), a full refund was granted on the Mechanical Permit. Due to this oversight an additional $33.54 is owed to the applicant. This amount should be refunded from Account 000.345.830 Mechanical (Res). Please forward the check to me and I will forward it on to the applicant. Thank you! City of 'Tukwila, Deportment of Comnumity Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax. 206-431-3665 Web site: hut://www.ci. mine ila.wa. us SET RECEIPT Copy Reprinted on 05-01-2013 at 15:56:42 05/01/2013 RECEIPT NO: R13-00124 Initials: JEM User ID: 1165 Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE) Payment Date: 01/09/2013 Total Payment: 13,045.45 SET ID: S000001897 SET NAME: Temporary Set SET TRANSACTIONS: Set Member Amount D13-004 1,018.34 D13-005 1,239.61 D13-006 1,313.36 D13-007 779.67 D13-008 1,116.68 D13-009 1,141.27 D13-010 1,313.36 D13-011 1,092.10 D13-012 1,239.61 D13-013 1,092.10 M13-003 167.70 M13-004 186.50 M13-005 177.10 M13-006 167.70 M13-007 177.10 M13-008 177.10 M13-009 124.25 M13-010 177.10 M13-011 167.70 M13-012 177.10 TOTAL: 1,018.34 OOU'-{; .120 ? btv\ V t9,1`\ .23e\ 000.252-2 . I () P►v‘k 4 f ly ,H(5 p. t L_ L10 23 1. ilL\ Nfi y . g7 Deo, inArx/h,-a.1 4141 *10 x 00 \(\,"'' vitk TRANSACTION LIST: Type Method Description q.4, -J t02, Amount Payment Credit C VISA 13,045.45 TOTAL: 13, 045.45 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 6,849.15 May 21, 2013 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director KC International Airport ATTN: Pamela Keuhl AIR TR -0200, 2nd Floor Terminal 7277 Perimeter Rd S Seattle, WA 98108-0245 RE: Refund for Permit Numbers D13-004 & M13-003 Ochoa Residence —11863 44 Av S Dear Ms. Keuhl, Per your request for permit cancellation and the fact that other construction issues conflict with the project, the permits for the KCIA Residential Aircraft Noise Remedy Improvement Program located at 11863 44 Avenue South have been cancelled and refunds granted. Per the Building Official an eighty percent refund of building permit fee has been processed as well as a full refund of the mechanical permit. Please find the enclosed check in the amount of $625.72 (six hundred twenty-five dollars and seventy-two cents). File: Permit No. D13 -004&M13-003 Encl: Check No. 363405 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 MEMORANDUM TO: Laurie Anderson FROM: Brenda Holt DATE: May 1, 2013 SUBJECT: Ochoa Residence Permit Numbers D13-004 & M13-003 Please draw a check in the amount of $625.72 (six hundred twenty-five dollars and seventy-two cents) to be payable to King County International Airport. The address to referenced on the check should read as follows: King County International Airport/Boeing Field ATTN: Pamela Keuhl AIR TR -0200 7277 Perimeter Rd S 2"d Floor Terminal Seattle, WA 98108-0245 The contractor has requested cancellation of the permit and refund due to extenuating circumstances which have made it impossible for the homeowners to participate in the King County International Airport Residential Aircraft Noise Remedy Improvement Program (RANRIP). Consequently the architect requested cancellation and refund of these permits on behalf of the County. The Building Official has reviewed the request and approved an eighty percent refund of permit fees as shown below: Account 000.322.100 Permit: $491.56 Account 000.345.830 Mechanical (Res): $134.16 Please forward the check to me and I will forward it on to the applicant. Thank you! City of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite 4100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: hrm://www. ci. aikwila. wa. us SET RECEIPT Copy Reprinted on 05-01-2013 at 15:56:42 05/01/2013 RECEIPT NO: R13-00124 Initials: JEM Payment Date: 01/09/2013 User ID: 1165 Total Payment: 13,045.45 Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE) SET ID: S000001897 SET NAME: Temporary Set SET TRANSACTIONS: Set Member Amount D13-004 D13-005 D13-006 D13-007 D13-008 D13-009 D13-010 D13-011 D13-012 D13-013 M13-003 M13-004 M13-005 M13-006 M13-007 M13-008 M13-009 M13-010 M13-011 M13-012 TOTAL: 1,018.34 1,239.61 1,313.36 779.67 1,116.68 1,141.27 1,313.36. 1,092.10 1,239.61 1,092.10 167.70 186.50 177.10 167.70 177.10 177.10 124.25 177.10 167.70 177.10 1,018.34 000. 2.1 _0v eyva 4 O V- , L— x p. 8 U1 -1Q. 231. icy NA M. coo, 3L C. Voci Lta, 4 4141..10 X 0 q'OW tas-,12- TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,045.45 TOTAL: 13, 045.45 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 6,849.15 S.M. STEMPER • ARCHITECTS A Professional Limited Liability Company April 15, 2013 Bob Benedicto, CBO ATTN: Bill Rambo City of Tukwila 6300 Southcenter Blvd., Ste. 100 Tukwila, WA 98188 RE: Building Permit Cancellation and Request for Refund Dear Mr. Benedicto: CITY OF TV ED Kw/LA APR 2 4 2013 PERMIT CENTER You recently issued us building and mechanical permits D13-004 and M13-003 for the property at 11863 44th Ave. S. The homeowners were participating in the KCIA Residential Aircraft Noise Remedy Improvement Program (RANRIP), but have other construction issues occurring at their home that will not allow them to participate at this time. This letter serves an official request to cancel the current permits and to request a refund of the permitting fees. A refund check can be issued to Pam Keuhl, King County International Airport / Boeing Field, Department of Transportation, AIR TR -0200, 7277 Perimeter Road South, 2nd Floor Terminal, Seattle, WA 98108-0245. You can contact me if there are any questions. Timothy J. enlason The Jones Payne Group Cc: S.M. Stemper Architects Tony Wasser r &RNA, ak.e.,04vA -17,440...0o, -fro /44,1,44 - ¢/3ofrd3 4000 DELRIDGE WAY SW • SUITE 200 • SEATTLE, WA 98106 • (206) 624-2777 • FAX (206) 624-2973 *PERMIT COORD COPS; PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-003 DATE: 01/07/12 PROJECT NAME: OCHOA RESIDENCE SITE ADDRESS: 11863 44 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter #_ Revision # after Permit Issued DEPARTMENTS: �S mac. 1-11-1-1-5 Building Division II Public Works D X51 01 t o `iS Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete rt Comments: Incomplete ❑ DUE DATE: 01/10/13 Not Applicable ❑ Permit Center UseOnly INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route $Z Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 02/07/13 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople Printer Friendly Page J General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type G & G SPECIALTY CONTRCTORS INC 4809214079 4633 S 36Th Street Phoenix AZ 85040 Out Of State Corporation Parent Company G & G SPECIALTY CONTRCTORS INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602975812 Active GGSPEGS919RT Construction Contractor 12/31/2009 12/31/2013 General Unused Business Owner Information Name Role Effective Date Expiration Date GOODBALLET, CHARLES ELMER Chief Executive Officer 12/28/2009 Bond Amount WAVY, CHRISTINE Chief Operating Officer 12/28/2009 59BSBEA9058 GOODBALLET, JAMES SCOTT President 12/28/2009 GOODBALLET, TERESA LYNN Secretary 12/28/2009 INS CO OF THE WEST Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 HARTFORD FIRE INS CO 59BSBEA9058 12/18/2010 Until Cancelled $12,000.0001/03/2011 11/16/2012 1 INS CO OF THE WEST 2278440 12/18/2009 Until Cancelled $12,000.0012/28/2009 12/27/2011 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date' 4 Companion Property & Cas Ins C PCP10000270101 11/03/2012 11/03/2013 $1,000,000.00 11/16/2012 3 National Union Fire Ins of PA PCP1000027 11/03/2011 11/03/2012 $1,000,000.00 12/27/2011 2 LEXINGTON INS CO 4392611702 12/31/2010 12/31/2011 $1,000,000.0001/11/2011 1 CEOXINGTON INS 4392611701 12/31/2008 12/31/2010 $1,000,000.0001/14/2010 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 01/15/2013 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASH RAE BFC BFF BOD BTUH CD• CFM CIRC CON D CON T COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC TDH TOD TPD TSP TYP V VD VTR WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE= ARCHITECT AmERIDAN. SOCIETY OF HEATING, REFRIGERATION AND AIR. :CONDITIONING ENGINEERS BELOW !FINISHED CEILING BELOW FINISHED FLOOR BOTTOM. OF DUCT BRITISH THERMAL UNITS PER OUR. CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE, DIAMETER DIMENSION DOWN DRAWING EXISTING EACH. EXHAUST AIR .ELEVATION ENTERING AIR. TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST' EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE: FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER :CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1090 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING= WATER TEMPERATURE, MAXIMUM 1000 BT.) PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED: NOT IN. CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR. OUTSIDE AIR. TEMPERATURE. ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN, GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE, SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL :STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE. WET BULB TEMP=ERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE: CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL XX Alma DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN OR X, 0 X/Y //////////, DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS AND DETAILS. NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ,ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL woRK. As IDENTIFIED IN THE spEoFicATIoNs.: WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRANjNo AND WARRANTY OF THE MECHANICAL SYSTEMS As SHOWN AND, SPECIFIED. PROVIDE A COMPLETE AND. OPERABLE MECHANICAL SYSTEM .COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED .FOR SYSTEM .OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS. LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE ,SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA,: AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE :INSTALLATiaN WITH ALL TRADES ,AND GUARANTEE IN :WRITING THAT NO ,ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT, DO NOT SCALE FROM 4. DIMENSIONS .SHCWN, FOR DUCTWORK REQUIREMENTS DUCTWORK PENETRATIONS THROUGH AIRTIGHT. PLANS. WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9 WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4? -0" AFF. UNLESS NOTED OTHERWISE 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG -X XXX -el- EQUIP ID# NG • VD RA/EA DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLU ME DAMPER RETURN AIR OR EXHAUST AIR :DUCT RG RETURN AIR GRILLE SA SA RA/EA SD EA MOD NG SUPPLY AIR OUTLE SUPPLY AIR DUCT SIDEWALL RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE:/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE. APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / •ELEc: L COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURN SHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION 23 26 23 26 N /A 23 26 N/A REMARKS BV -1 BLENDING UNIT .VENTILATOR 120 1 X X X 1,2 SWITCHES (ON, TIMER) 120 1 X X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS .(TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC: DIMENSIONS ELECTRICAL WATTS VOLTS PHASE COMMENTS BV -1 140 .5" WG 321x12,25"Wx8.5"H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS SG -1 140 <08" WG 8 CEIUNG ALLGRILLE 1, 2, 4 00-1. 90 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3 RG -1 25: <08" WG 4" 4" CEILING DECO 1, Z 4 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN iNsTRucTioNs 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 3. PROVIDE WITh BACKDRAFT DAMPER AND INSECT SCREEN 4, BASIS OF DESIGN: ALDES A. OR APPROVED:, ,EQUAL. WAC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2030 708 2 90 CFM 90 CFM 1 1. VENTILATION PROVIDED.' PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), sEcTioN. 51-51-1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATIO N THICKNESS DUCT LOCATION MIN VALUE NOTES ON ROOF OR. ON EXTERIOR OF 'BUILDING. R-8 WITH WEATHERPROOF BARRIER 13 ATTI C, GARAGE. CRAWL SPACE. IN WALLS, IN FLOOR/CEILING R-8 1,2,3 WIWI N CONDITIONED SPACE OR IN HEATED BASEMENTS R-8 1,3 IN CEMENT SLAB OR 1N GROUND R-5 1,3 NOTES: 1. THICKNESS OF INSULATION IS. DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM. NOT INCLUDING FINISHING MATERIALS, 2. INSULATION MAY BE OMITTED. ON THAT :PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND. WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO .CONDITIONED 3. REFER TO WASHINGTON. STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS, SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Electrical Crumbing rias Piping of Tukwila r G DIVISION . • ._.. DRAWING NO ES: 1. °ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW 'THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT, 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. SWITCH HOURS OF COPY PM,* NO. 3 Pp,» r-,fiGIN approval is subject to errors and omissions. L.urt construction documents does not authcr!za Jon oi arty adopted code or ordirtance. Recpt 'IP • 110'47.0... is acknowledged: 01 Cop f $.11 HI!•. 4/ By Date' City Oflbkwlla BUILDING DIVISION OPERATION SET SWITCH TO OPERATE 1 OF EVERY 2 HOURS. REVIEWED FOR CODE COMPLIANCE APPROVED MECHANICAL VENTILATION JAN 1 4 2013 IL City of Tukwila BUILDING DIVISION CALCULATION PER WAC 51-51, SECTION M1508.3 QF = QR (&EGR X F) QR = (FROM TABLE 403.8.1) 4..„9. &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 45 / (1 X 1/2) = 90 CFM REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division rov;sions will require a new plan submittal Lid may irickie additional plan review Ices. RECEIVED clTv OF TUKWILA I JAN 0 7 2013 PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS 2 Professional Wailed Lialrility Company 4000 DELRIDGE WAY SW SUITE 200 sums, wA SEIOS (200) 624-2777 ^ 1.42 (200) 824-2270 THE GREENBUSCH GROUP, INC * 040600 ) ) 110043611211824° 9116111 SATE 201.121222,1610611 (206) 378-05450 (200) 37111541FAX RESIDENTIAL ARC AP NUMBER 3-5841058-044: 0 co DATE 0810512012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO PRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M 1.0 0810,03.2030 3EIFOOM TYP TO BV •1 RG -1 25 SG -1 140 L 1 V1NG R0011 SEE CEILING GRI CitC, x 24' EMT. ATTIC Arzess F'ANEL BEDROOM RG -1 2 25 TYP ALL LLES (E)EG BATH 1 PAUL aluNG (E)EG DRYER VENT 6UN ROOM KITCHEN MOTOR ACCESS FILTERS ACCESS SUPPLY DUCT NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLAlION. 2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.. 3. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WIThl TECHNICAL REPRESENTATIVE SHEETMETAL TRANSITION TO WALL CAP NECK SIZE 4"0 DN TO RG -1 TO TIMER SWITCH 1 1 11 11 4,0 E -11 HOLD DUCT TIGHT a"o ON TO ROOF, TYPICAL TO. SG -1 LOCATE OUTSIDE AIR INTAKE ON GABLE WALL ABOVE ROOF 40- OG -1 90 JL I ATTIC MECHANICAL PLAN SCALE: 1/4" = 2X BLOCKING FOAM. BACKER. ROD WALL CAP DUCT PER PLAN. MU. 2X BLOCKING - SLEEVE AND ESCUTCHEON WALL. NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3, COORD. W/ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL. WALL CAP DETAIL SCALE: NONE SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE 2X BLOCKING NORTH SLEEVE AND ESCUTCHEON GRILLE DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE FOAM BACKER ROD CAULK 2X BLOCKING FLOOR OR CEILING JOIST BUNG NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. DRAWING NOTES: FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS' SOURCE PER WAC 51-51, $01111)14: 2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING .AIR UNIT SYSTEMS INITH NEW FILTERS. FLAG....OTES: . • BV -1 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51, SECTION M1508.6.4. COORDINATE FINAL SWITCH LOCATION WITH HOMEOWNER. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET. APPLY ACOUSTICAL DAMPING COMPOUND TO INTERIOR FACES OF WALL CAP. COORDINATE PAINT ON WALL CAP EXTERIOR FACES WITH ARCHITECT. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 4 2013 City of Tukwila BUILDING DIVISION RECEIVED env OF TUMMILA 1JAN tO 7 2013 PERMIT CENTER I EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS Professional Limited Liability Compaq 40Q0 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 9810( (206) 024-277'7 ^ PAX (BOO) 024-6676 THE, GREENBUSCH GROUP, INC Oa OP s4114*. ACOUSTICAL. AUDIO / 11160 11169fieJ1. 001014160110 1000 WEST NOMN SOW SATE 101 SWILL 116 *110 (200) 579-0502 (200) 376-0041 FM MPROVEMENTS FT NOISE REMED 0 LLI0 CT) AIP NUMBER 3-53-0058-044 0 z PATE - DATE 06/05/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHAN ICAL FLOOR PLANS AND DETAILS MLO 0810.03.2030