Loading...
HomeMy WebLinkAboutPermit M13-005 - ARAGON RESIDENCE - ALTERATIONARAGON RESIDENCE 4610 S 124 ST M13-005 City aTTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0179000995 Address: 4610 S 124 ST TIIKW Project Name: ARAGON RESIDENCE Permit Number: M13-005 Issue Date: 01/15/2013 Permit Expires On: 07/14/2013 Owner: Name: ARAGON D Address: 4610 S 124 , SEATTLE WA 98178 Contact Person: Name: Address: Email: SHARYN PARKER 7277 PERIMETER RD S , SEATTLE WA 98108 SHARYN.PARKER@KINGCOUNTY. GOV Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST , PHOENIX AZ 85040 Contractor License No: GGSPEGS919RT Phone: 206 296-7437 Phone: 480-921-4079 Expiration Date: 12/31/2013 DESCRIPTION OF WORK: FRESH AIR SERVICING FOR SOUND REMEDIATION WORK. Value of Mechanical: $2,643.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature I hereby certify that I have read an governing this work will be compli Fees Collected: $177.10 International Mechanical Code Edition: 2009 Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pre construction or the performance of work. back of this permit. Signature: Leg Print Name: J 0 L 'c /l. This permit shall become null and voi�if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: 1 —' S /14 4C 01/149 PERMIT CONDITIONS Permit No. M13-005 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. rinr•.• IM( -4/1(1 rum-nnPrintarl• n1 -1F-9813 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. . P ojectNo.` Date Application Accepted: .Date:ApplicationExpires: (F,or_office use only') .' MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 0179000995 Site Address: 4610 S. 124th St. Suite Number: New Tenant: Tenant Name: Daniel Aragon PROPERTY OWNE'R . . Name: Sharyyn Parker, Program Manager Address: 7277 Permieter Road South Name: Daniel AAragon Phone: (206)296-7437 Fax: (206)296-7315 Email: Sharyn.Parker@kingcounty.gov Address: 4610 S. 124th St. State: City: Tukwila State: WA Zip: 98178 CONS CT PERSO,•Nrij person•receiving all,project communication : ,k i it "• ' ,:�t s,1 i ..:- ._. . Name: Sharyyn Parker, Program Manager Address: 7277 Permieter Road South City: Seattle State: WA Zip: 98108 Phone: (206)296-7437 Fax: (206)296-7315 Email: Sharyn.Parker@kingcounty.gov Floor: ❑ Yes ..No MECHANICAL..CONTRAC :#51NFOtRMATION_. Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 2643.00 Describe the scope of work in detail: Fresh air servicing for sound remediation work. Use: Fuel Type: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Electric ❑ Gas ❑ Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Pemtit Application Revised 8.9.11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN Signature: RI ED AGENT: Date: 1/71)3 Print Name: es- Holgate Day Telephone: (206)624-2777 Mailing Address: 4000 Delridge Way SW. #200 H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Seattle WA 98106 City State Zip Page 2 of 2 City a ukwilar Departmento� Community Development 6300 Southcerter Boulevard, Suite #I00 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: hito:/tvww.ci.tukwiln.wa.us SET RECEIPT RECEIPT NO: R13-00124 Initials: JEM Payment Date: 01/09/2013 User ID: 1165 Total Payment: 13,045.45 Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE) SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT SET TRANSACTIONS: Set Member Amount D13-004 1,018.34 D13-005 1,239.61 D13-006 1,313.36 D13-007 779.67 D13-008 1,116.68 D13-009 1,141.27 D13-010 1,313.36 D13-011 1,092.10 D13-012 1,239.61 D13-013 1,092.10 M13-003 167.70 M13-004 186.50 M13-005 177.10 M13-006 167.70 M13-007 177.10 M13-008 177.10 M13-009 124.25 M13-010 177.10 M13-011 167.70 M13-012 177.10 TOTAL: -i 918 : 3'tl•" ID, ooc • 14�_ TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,045.45 TOTAL: 13, 045.45 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 6,849.15 City,q7ukwilar Deparime 7llof Commun ity Developnm en t 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site' hop •/brwir ci rukwila wa us STATE BUILDING SURCHARGE 640.237.114 45.00 TOTAL: 13,045.45 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 4' MRoos Project: 0 Ai Type f Inspection: Address:AA-6 6 (0 f rL /...Sr Date d �'...� V .` -A - Special Instructions: / Date Wanted:.? > ! a:m: Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: J�-� e,c�• , j--.` ti --- E f r Inspector 1l1 Date: 1-7 1.--j REINSPECTION FEE REQUIRED. Prior to next inspection, fed -must be' paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection:; •PERMIT COORD COPS PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-005 DATE: 01/07/12 PROJECT NAME: ARAGON RESIDENCE SITE ADDRESS: 4610 S 124 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: AT C_ 14-t-13 DC SI Ol'1V•l5 Building Division Fire Prevention Public Works Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 01/10/13 Complete T:f Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route Ej Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 02/07/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Printer Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company G E G SPECIALTY CONTRCTORS INC 4809214079 4633 S 36Th Street Phoenix AZ 85040 Out Of State Corporation G & G SPECIALTY CONTRCTORS INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602975812 Active GGSPEGS919RT Construction Contractor 12/31/2009 12/31/2013 General Unused Business Owner Information Name Role Effective Date Expiration Date GOODBALLET, CHARLES ELMER Chief Executive Officer 12/28/2009 Bond Amount WAVY, CHRISTINE Chief Operating Officer 12/28/2009 59BSBEA9058 59BSBEA9058 GOODBALLET, JAMES SCOTT President 12/28/2009 GOODBALLET, TERESA LYNN Secretary 12/28/2009 INS CO OF THE WEST Bond Information Page 1 or 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 FIRE INS HA2 CO 59BSBEA9058 59BSBEA9058 12/18/2010 Until Cancelled $12,000.0001/03/2011 11/16/2012 1 INS CO OF THE WEST 2278440 12/18/2009 Until Cancelled $12,000.00 12/28/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 Companion Property & Cas Ins C PCP10000270101 11/03/2012 11/03/2013 $1,000,000.00 11/16/2012 3 National Union Fire Ins of PA PCP1000027 11/03/2011 11/03/2012 $1,000,000.00 12/27/2011 2 LEXINGTON INS CO 4392611702 12/31/2010 12/31/2011 $1,000,000.0001/11/2011 1 LEXINGTON INS CO 4392611701 12/31/2008 12/31/2010 $1,000,000.0001/14/2010 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 01/15/2013 ABBREVIATIONS • LEGEND DR AWING. INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E. EXIST EA ELEV. EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG M FG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC So SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR WB WG WAC ASBESTOS CONTAINING MATERIALs. AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE. ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR :CONDITIONING ENGINEERS BELOW. FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT THERMAL UNITS PER OUR CEILING DIFFUSER CUBIC FEET PER MINUTE. CIRCULATING CONDENSATE' CONTINUATION COORDINATE COLD WATER DEGREE, DIAMETER DIMENSION DOWN' DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL 'STATIC- PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER:, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE: FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS* AND DIFFUSERS::: GYPSUM WALLBOARD HORSEPOWER HEATING,. VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER ,CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY' INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL :GRILLE LEAVING WATER TEMPERATURE. MAXIMUM - 1000 BTU. PER HOUR. MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED. NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR. OUTSIDE AIR TEMPERATURE ON, CENTER.. OPPOSED BLADE DAMPER.: PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE, SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE .MECHANICAL CODE SCREENED OPENING, STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE. RESIDENTIAL CODE TOTAL DYNAMIC HEAD. TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL ✓ OLT. VENT VOLUME DAMPER VENT THRU ROOF WASTE W ET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LI STED SYMBOL xx AME oR XX 4 .111111111S DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LIN DIRECTION E OF FLOW EQUIPMENT ITEM XX LINE. ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EKISTiNG WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS. M2.1 MECHANICAL FLOOR PLANS AND DETAILS GENERAL NOTES' 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM. INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN Or MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED' BY THE MANUFACTURERS :LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED FRov1oE0 THAT THE' EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE IINSTALLATION WITH ALL TRADES ,AND GUARANTEE IN 'WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND: SITE DIMENSIONS BEFORE BEGINNING :CONSTRUCTION OR 'ORDERING EOURMENT. DO NOT Sox": FROM PLANS. 4. DIMENSIONS SHCWN, FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH :INSULATION INSTALLED. :INSULATION, SHALL MEET. V.VASHINGTON. STATE ENERGY CODE (WSEC)1 CHAPTER 5, 5019 REQUIREMENTS., 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CE AIRTIGHT. INGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. EL COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS *-0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10' -OP CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAM ING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN S -Cr CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG -X XXX ABBR -•.DN DN + I -UPI + UP S ri 0-4 •0 4N- "--ii,101111_ vo RA/EA RG SA SA RA/EA SD DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMEN (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE TS EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH OR THERMOSTAT EQUIP ID#'s. EQUIPMENT LOCATION NG • 0 MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL / EL ECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTION voLTs PH FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION 23 26 23 26 N/A 23 26 N/A REMARKS BV -I BLENDING UNIT VENTILATOR 20 X X 1,2 SVV1TCHES (ON, TIMER) 120 X X x MOTOR .OPE RATED DAMPER 24 X X X 1,2 THERMOSTAT 24 X X x REMARKS: I - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BL ENDING ,UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL WATTS VOLTS PHASE COMMENTS BV - 115 32LX12, 25'Wx8.5"H 76 120 I, Z, 3 NOTE: I. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAWS) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND D FFUSER SCHEDULE MARK CFM STATI PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS SG -I 115 <..08° WG 7" 7" FLOOR 350 2, 5, 6 OG -1 90 WG 7" 6" WALL WALL CAP I, 2, 3, 4 RG -I 25: <.(18" WG 4' 4" FLOOR I, 2, 5, 6 REMARKS: I. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 3,, PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 5. BASIS OF DESIGN:. SHOEMAKER A, OR APPROVED EQUAL. 6. PROVIDE WITH AN OPPOSED BLADE DAMPER WA LL CAP SCHEDULE MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZE REMARKS WCI EXTERIOR: 00 337 7"0 1,2 REMARKS: 1. PROVIDE ALL WALL CAPS WITH INSECT SCREEN: 2. BASIS jFOR DESIGN FAMCO HOODED WALL VENT .4. OR APPROVED EQUAL SEPARATE PERMIT REQUIRED FOR: O Mechanical ittlectrical Orrlumbing Gel POMO City of Tukwila BU:W4G DIVISION WAC FLOOR AREA (SQ. FT.) NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2224 MOD 1311 3 90 CFM 90 CFM 0810.03.2224 BV -I 339 90 CFM 90 CFM I, VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES MI508..2 AND MI508.3 MINIMUM DUCT INSULATION THICKNESS UCT LOCATION MIN -VALUE • NOTES 0 N :ROOF QR ON EXTERIOR {F BUILDING - R-8 WITH WEATHERPROOF IBARR1ER 1.3 A TTIC, GARAGE. CRAWL SPACE, IN WALLS, IN FLOOR/CEILING R-8 L2.3 WITHIN CONDITIONED :SPACE OR IN HEATED BASEMENTS R-8 1.3 N 'CEMENT SLAB OR IN GROUND R-51 1.3 NOTES: 1, THICKNESS. OF IS DEFINED AS THE THICKNESS OF THE. BASIC: INSULATING rEDIUm NOT INCLUDING; FINISHING MATERIALS. 2. INSULATION MAY Ef OMITTED ON THAT PORTION, OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND WHERE THIS SPACE iS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR. 3. REFER TO WASHINGTON STATE:ENERGY CODE FORHAODITIONAL REQUIREMENTS, TH DRAWN G NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. ERMOSTAVSWI'TCH HOU RS. OF OPERATION SET FURNACE THERMOSTAT/SWITCH TO OPERATE *I OF EVERY 2 HOURS. SET swiToH Tft'OPERATE' 1 OF EVERY 3 HOURS, REVISIONS No changes Shall be made to the scope of work without prior approval of Tukwila Building Division. Revisions will require a new plan submittal and may include additional plan review fees. RECEIVED ortv OF ItImA/ILA 1JAN 07 20131 PERMIT CENTER FORRAC E KCHA: .................................... CA. LCULATION PER WAC 51-51 M1508.3: QF = QR (&ECR QR •=- (FROM TABLE M1508.2) 43_ VENTILATION EFFECTIVENESS (EXCEPTION: IF SYSTEM OPERATES 1 OF EVERY 3 HOURS),!=. -•1 = FRACTION OF OPERATION 1y2 QF = 45 / (1 X 1/2) = 90 CFM BV -1 MECHA NICAL VENTILATION CALCULATION PER WAC 51-51 M1508.3: QF = QR / (&EGR X F) OR = (FROM TABLE M1508.2) Q. &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/3 QF = 30 / (1 X 1/3) = 90 CFM FIE -• - Permit No. k 10,129 min approval is subject to Profs and omissicm ii.37i-ova! of construction documents does not authcite ,;:ation of any adopted code or ordinance. Receipt Lpprov • Id conditions IsWeiowledget By (/ Date: City Of 1111cwila BUILDING DIVISION REVIEWED CODE COMPLIANCE APPROVED JAN 1 4 ?nil Pc-) kittiU City of Tukwila BUILDING DIVISION EXPIRES: 9/08/21:112 S.M. STEMPER ARCHITECTS A Prof Ilraftent L101117 Complaw 4000 DELRIDGE WAY SW SUITE 200 SHEITLE. WA 0510S 05) 224-2777 PAX (200) 024-2072 THE GREENBUSCH GROUP, INC 0.400 6600 COUSIVAL., AU_010_ / $11020 * illECHVICOL EIONEE1020 1000 leg SUITE SEME. (206) 373-0560 (206) 375-0641 FAX 0810.032224 ce 0 ce z 0 z w 0 z MPROVEMENTS AIP NUMBER 3-53-0058-044 DATE 08/05/2012 ISSUED 100% OD. PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., •GENERAL NOTES, & DWG INDEX M .0 osi 0.03,2224 DRAWING. NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10:' FEET AWAY OR 3 FEET BELOWANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 5151;, SECTION M1.50844, 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51-51, SECTION M1508.5.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. 4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS. BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. LJ C-..) LOWER FLOOR SCALE: 1/4" = V-0" FLAG. NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. REMOVE THE EXISTING THERMOSTAT AND PROVIDE WSEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VEN1LATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51, SECTION. M1508.5.2. COORDINATE .FINAL SWITCH LOCATION WITH HOMEOWNER. INSULATE ALL DUCT AS SCHEDULED, REFER TO THE MINIMUM DUCT INSULATION. THICKNESS SCHEDULE ON M1.0. BV -1 AND DUCTWORK ROUTED IN STORAGE SPACE. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL. .REPRESENTATIVE. STORAGE MECHANICAL. PLAN :QIN • NORTH LIVING ROOM (E)S0 KITCHEN HOLD DUCTS TIGHT TO JOISTS sTafeedae TO TIMER SWITCH SEE 19. SEE N 7'0 UP TO SG -1 OO - CLOSET SITTING (E)SG E3EDOOM 3 MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1 NORTH 4110 UP TO RG -1 005 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 14 ?nil City of Tukwila BUILDING DIVISION RECEIVED CITV OF TumAnIA 'JAN 07 2011 i.)ERMITCENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS . Professional ffrottea Lisbilllor COMpftDy 4000 DELRIDGE WAY SW SUITE 200 SEATTLE, WA 08100 2777 ^ PAT (202) (124-2072 THE. GREENBUSCH GROUP, INC )))00 0 0 0 0 Immix° wirriaggiS04AS tin In WI (200 va—cusee 376-0041 FM 0810.03.2224 MPROVEMENTS RESIDENTIAL AIRC AIP NUMBER 3-53-0058-044 DATE 06/05/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL FLOOR PLANS M2.0 0810 03.2224 FLAG NOTES: FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET OF FURNACE RETURN INLET PER WAC 51-51, SECTION M1508.5.1. CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOWFOR BALANCING THE OUTSIDE/RETURN AIR TO. PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A VOLUME DAMPER EXISTS IN THIS LOCATION,. IT MAY BE REUSED. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51, SECTION M1508.6.4. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. L L — r H 1 TYP SEE x t EMST, ATTIC ACCESS PAM - ATTIC 11111 1 1 I 1 111 I MECHANICAL. PLAN SCALE: 1/4" = 411IFRTH rpi ALL FLOOR GRILLES z LJ LiJ CEILING OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER: PLAN VOLUME D.AMPERI FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING FURNACE MOD, INTERLOCK TO FURNACE FLUE. POC FLOOR FU RN ACE ELEVATION SCALE: NONE SHEETMETAL TRANSITION TO WALL CAP NECK SIZE DUCT PER PLAN CAULK 2X. BLOCKING NOTES: M (1; 2X BLOCKING FOAM BACKER ROD WALL CAP OUTSIDE AIR DUCT RETURN AIR DUCT MOD. BV -i HOLD TIGHT TO STRUCTURE SUPPLY AIR DUCT MOTOR ACCESS FILTERS ACCESS NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 3. INSULATE ALL DUCT AS SCHEDULED. •SLEEVE AND ESCUTCHEON WALL 1. INSTALL. PER. MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. -SEE PLANS FOR VOLUME DAMPER ILOCATJONS. 3. CO.ORa W/ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL WALL CAP DETAIL. SCALE: NONE BV - INSTALLATION DETAIL SCALE: NONE SLEEVE AND ESCUTCHEON. 2X BLOCKING CAULK SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT, ROUTE PER PLAN. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 14 ?nil City of Tukwila BUILDING DIVISION FLOOR GRILLE FLOOR 2X BLOCKING FOAM BACKER ROD. NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTION 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. FLOOR GRILLE DETA SCALE: NONE L S. RECEIVED CITV OP rtnewitA IJAN 0 7 2013 PERMIT CENTER La is EXPIRES: 9/08/2012 STEMPER ARCHITECTS A Professional Waited Lisbilligy Crosprav 4000 1ELRIDGE WAY SW MATE 200 surra, WA 00100 (208) 024-2777 ^ PAX (208) 024,2075 THE GREENBUSCH GROUP, INC ) ) 4". '116 *1'4 • 01201191129., AUDIO 190E0 & IlECIONICOL EN06IEERIP10 1900 Vint. NO .N 611821 6182 201 SEAM. IR 101111 (2011) 376-0009 (200) 3711,0041 FAX 0810.032224 0 w z 0 CO 0 RESIDENTIAL AIR AIP NUMBER 3-53-0058-044 PATE 06/06/2012 ISSUED 100%CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL FLOOR PLANS AND DETAILS M2.1 0810.03.2224