HomeMy WebLinkAboutPermit M13-008 - CHRISTENSEN RESIDENCE - ALTERATIONCHRISTENSEN RESIDENCE
12212 48 AV S
M13-008
City* Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.: 0179001355
Address: 12212 48 AV S TUKW
Project Name: CHRISTENSEN RESIDENCE
Permit Number: M13-008
Issue Date: 01/15/2013
Permit Expires On: 07/14/2013
Owner:
Name: CHRISTENSEN TAYLOR R+DAVID
Address: 12212 48TH AVE S , TUKWILA WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Email: SHARYN.PARKER@KINGCOUNTY.GOV
Contractor:
Name: G & G SPECIALTY CONTRCTORS INC
Address: 4633 S 36 ST , PHOENIX AZ 85040
Contractor License No: GGSPEGS919RT
Phone: 206 296-7437
Phone: 480-921-4079
Expiration Date: 12/31/2013
DESCRIPTION OF WORK:
FRESH AIR SERVICING FOR SOUND REMEDIATION WORK.
Value of Mechanical: $2,085.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complied
aurin
th,
EQ)
Fees Collected: $177.10
International Mechanical Code Edition: 2009
Date: 00113
d this permit and know the same to be true and correct. All provisions of law and ordinances
hether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this pe
Signature:
Print Name:
b- 8k_qa
Date: /—/S--- l
This permit shall become null and void iif the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS
Permit No. M13-008
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431-3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
rinr. IMC -4/1n
M13-nnR Printprt• n1 -15-2n13
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No.
Project No.
Date Application Accepted:
Date Application Expires:
ollatiVeItiv1W4
��
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
Site Address:
12212 4th Ave. S.
King Co Assessor's Tax No.: 0179001355
Suite Number: Floor:
New Tenant: ❑ Yes m ..No
Tenant Name: Taylor Christensen
PROPERTY.OWNER
Name: Sharyyn Parker, Program Manager
Name: Taylor Christensen
City: Seattle State: WA Zip: 98108
Address: 12212 4th Ave. S.
Email: Sharyn.Parker@kingcounty.gov
City: Tukwila State: WA
Zip: 98178
CONTACT PERSON - person receiving all project
coin nunicatiou
Name: Sharyyn Parker, Program Manager
Address: 7277 Permieter Road South
City: Seattle State: WA Zip: 98108
Phone: (206)296-7437 Fax: (206)296-7315
Email: Sharyn.Parker@kingcounty.gov
MECIIA1N1CAL CONT t.ACTOR.INFORMATION
Company Name: TBD
Address:
City:
State:
Zip:
Phone:
Fax:
Contr Reg No.:
Exp Date:
Tukwila Business License No.:
Valuation of project (contractor's bid price): $ 2085.00 /
Describe the scope of work in detail:
Fresh air servicing for sound remediation work.
Use: Residential: New 0 Replacement 0
Commercial: New ❑ Replacement ❑
Fuel Type: Electric 0
Gas ❑ Other:
H:Wpplications\Focros-Applications On Line\2011 ApplicationsWechanical Permit Application Revised 8-9-1l.docx
Revised: August 2011
bh
Page 1 of 2
4
•
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
•
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNS OR UT Sf -ZED ; ENT: V7/13 Signature: Date:
Print Name: Jesse Ho1: e Day Telephone: (206)624-2777
Mailing Address: 4000 Delridge Way SW. #200
H:Wpplications\Forms-Applications On Line\2011 Applications+lechanical Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
Seattle WA 98106
City State Zip
Page 2 of 2
City o -Tukwila,
Department ' Community Developm en t
6300 Southcerter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http:/Avww.ci.tnlnvila.wa.us
SET RECEIPT
o
RECEIPT NO: R13-00124
Initials: JEM
Payment Date: 01/09/2013
User ID: 1165 Total Payment: 13,045.45
Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE)
SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT
SET TRANSACTIONS:
Set Member Amount
D13-004 1,018.34
D13-005 1,239.61
D13-006 1,313.36
D13-007 779.67
D13-008 1,116.68
D13-009 1,141.27
D13-010 1,313.36
D13-011 1,092.10
D13-012 1,239.61
D13-013 1,092.10
M13-003 167.70
M13-004 186.50
M13-005 177.10
M13-006 167.70
M13-007 177.10
M13-008 177.10
M13-009 124.25
M13-010 177.10
M13-011 167.70
M13-012 177.10
TOTAL:34- -
1221 MC'14C-
TRANSACTION
L C
TRANSACTION LIST:
Type Method Description
Amount
Payment Credit C VISA 13,045.45
TOTAL: 13, 045.45
ACCOUNT ITEM LIST:
Description
Account Code Current Pmts
BUILDING - RES
000.322.100 6,849.15
City ct%)Tukwilar
Departme Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Website: httn:/lvww.ci.tukwila.wa.us
STATE BUILDING SURCHARGE
�j
640.237.114 45.00
TOTAL: 13, 045.45
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Project:(p �*-�-� A 1 jJ
44-g_l, e 1.�•/v ' eS
Type f Inspecti n:
�iv A A e
Address:r} IIS/ A-vc
Dat ailed:/
r
?Dnt4TT
I
Special Instructions:
/
Date Wanted:
0vAS
1 �'3
1
(..-3
m.
Requester:
'"!
Phone No:
i
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
?Dnt4TT
I
\
0vAS
.
i
1
r
,
..,A
d '
Inspect r:
o4
REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
Date) 2'?—1)
• PERMIT COORD WC*
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: M13-008 DATE: 01/07/12
PROJECT NAME: CHRISTENSEN RESIDENCE
SITE ADDRESS: 12214 48 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
A-5 /IN(
Building Division
Public Works
kP 01• 10
Fire Prevention El
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete g]
Comments:
Incomplete ❑
DUE DATE: 01/10/13
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUESITHURS ROUTING:
Please Route 1Z Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 02/07/13
Approved ❑ Approved with Conditions 7 Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Contractors or Tradespeople�nter Friendly Page
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite/Apt.
City
State
Zip
County
Business Type
G & G SPECIALTY CONTRCTORS INC
4809214079
4633 S 36Th Street
Phoenix
AZ
85040
Out Of State
Corporation
Parent Company G e G SPECIALTY CONTRCTORS INC
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
602975812
Active
GGSPEGS919RT
Construction Contractor
12/31/2009
12/31/2013
General
Unused
Business Owner Information
Name
Role
Effective Date
Expiration Date
GOODBALLET, CHARLES ELMER
Chief Executive Officer
12/28/2009
Bond Amount
WAVY, CHRISTINE
Chief Operating Officer
12/28/2009
59BSBEA9058
GOODBALLET, JAMES SCOTT
President
12/28/2009
GOODBALLET, TERESA LYNN
Secretary
12/28/2009
INS CO OF THE WEST
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
2
HARTFORD FIRE INS
CO
59BSBEA9058
12/18/2010
Until Cancelled
$12,000.0001/03/2011
11/16/2012
1
INS CO OF THE WEST
2278440
12/18/2009
Until Cancelled
$12,000.00
12/28/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
4
Companion
Property & Cas
Ins C
PCP10000270101
11/03/2012
11/03/2013
$1,000,000.00
11/16/2012
3
National Union
Fire Ins of PA
PCP1000027
11/03/2011
11/03/2012
$1,000,000.00
12/27/2011
2
LEXINGTON INS
CO
4392611702
12/31/2010
12/31/2011
$1,000,000.0001/11/2011
1
CO LEXINGTON INS
4392611701
12/31/2008
12/31/2010
$1,000,000.0001/14/2010
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
01/15/2013
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
GA
GAL
GALV
GPM
GRD
GWB
HP
H VAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
N TS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
READ
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
SRC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
WB
W/
WG
WAC
ASBESTOS CONTAINING mATER1ALs.
AIR CONDITIONING:, UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN: SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED :CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE,
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
.ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE:
EXTERNAL .STATIC PRESSURE:
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE:
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR'
GRILLES, REGISTERS, AND: DIFFUSERS'
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY'
INCH
KILOWATT, . (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE.
LEAVING WATER TEMPERATURE,
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTEC11ON ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO: :SCALE.
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER,
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN. GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE:
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE mEoHANI0AL. CODE
SCREENED OPENINC'
STATIC PRESSURE
STATIC PRESSURE DROP -
SPECIFICATIONS
SEATTLE 'RESIDENTIAL CODE
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS L STED
SYNIBOL
<*>
OR XX
0
X/Y
CD4
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GEN
M2.0 MECHANICAL MEcHAN1c:AL.FLOOR PLANS AND DETAILS
ERAL. NOTES .: AND -DRAWING INDEX
GENERAL NOTES
1. THE MECHANICAL. SYSTEM SHALL CONSIST .OF .ALL WORK SHOWN ON THE D.RAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK As IDENTIFIED IN THE 'spEpppA110Ns. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED, PROVIDE. A COMPLETE AND OPERABLE MECHANICAL
SYSTEM :COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED. FOR SYSTEM OPERATION.
2, THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT' AS MANUFACTURED BY THE MANUFACTURERS. LISTED ON THE 'EQUIPMENT SCHEDULE, EQUIPMENT .NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED. PROVIDED THAT THE EQUIPMENT MEETS OR ExcEEDs, ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL ..REPRESENTATIVE„ COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN :WRITING THAT No Ammo:NAL COST WILL: BE INCURRED DUE TO PRODUCT suasirroTIDN,
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING :CONSTRUCTION* OR 'ORDERING EQUIPMENT. DO NOT SCALE FROM
4. DIMENSIONS SHOWN, FOR DUCTWORK WITH INSULATION SHALL BE NET FREE 'DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9
REQUIREMENTS.
5, DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN
THERMOSTATS 4'-O" AFF. UNLESS NOTED OTHERWISE.
PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLU
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
MAINTAIN 101-0' CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
PROVIDE FRAM NG, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
DUCTS SHALL BE SEALED
THE ELECTRICAL CONTRACTOR.
ON THE DRAWINGS ARE FOR REFERENCE IONLY. LOCATE
DING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
SYMBOL
"SP,I=X
XXX
ABBR
+r
ei-
0 a -
c>i
T.7 (p, THERMOSTAT
EQUIP ID# EQUIPMENT LOCATION
DESCRIPTION
DIFFUSER, IREGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
VD
RA/EA
RG
SA
SA
RA/EA
SD
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMEN
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR. DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
TS
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
17,
NG
0
MOD
NG
MOTOR OPERATED DAMPER
NATURAL ppE
piREIDucT ELBOW DOWN
PIPE/DUCT ELBOW, UP
BALL VALVE:
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL/ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
DE S CRIPTI ON
VOLTS
PH
FURNISHED
UNDER DIVISION
INSTLLED
UNDER DIVISION
WIRED
UNDER DIVISION
23
26
23
26
N/A
23
2.6
N/A
REMARKS
M
OTOR OPERATED DAMPER
24
X
1,2
THERMOSTAT
24
X
REMARKS:
- 'VERIFY QUANTITY FROM PLANS (TYP CAL ALLY
2 - DISCONNECT SWITCH
WALL CAP SCHEDULE
MARK
LOCATI ON
CFM
AIR
VELOCITY PPM
STATIC
PRESSURE
SIZE
REMARKS
WC -1
EXTERI
90
337
<•08"WG
7"12)
1,2
REMARKS:
I. PROVIDE ALL WALL CAPS WITH INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
WAC
RESIDENCE CODE
FLOOR AREA
(SQ. FT)
NUMBER OF
BEDROOMS
CODE REQUIRED
VENT' LATI ON
VENTILATION
PROVIDED
NOTES
081.0,03..2227
772
3
90 CFM
90 CFM
1. VENTILATION PROVIDED PER THE WASHINGTON ADMIN1STRATIVE CODE (WAC),
SECTION 51.51-1.608, TABLES M1508,2 .ANI) :MI508,3
MINIMUM DUCT INSULAT
ION THICKNESS
DUCT LOCATION
MIN VALUE
NOTES
ON ROOF OR ON EXTERIOR: OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
L3
ATTICGARAGE, CRAWL SPACE,- IN WALLS, IN. FLOOR/CEILING
L2.3
WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS
1.3
CEMENT SLAB OR IN .GROUND
R-5
NOTES:
I. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT iNewpmiG. FINISHING MATERIALS.
2. INSULATION MAY RE OMITTED ON THAT PORTION OF A 'DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXFO$ED TO UNCONDITIONED AIR AND
WHERE SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR.
3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
REVISIONS
No Osnges shall be made to the scope
of work without prior approval of
Tukwila Building Division.
Rvialans will require a new plan submittal
C.11.1 may include additional plan review fees.
SEPARATE PERMIT
REQUIRED FOR:
0 Mechanical
riftlectrical
&Plumbing
Effas Piping
City of Tukwila
BUILDING DIVISION
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS.
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 0111.01 AND 028200 FOR REGULATED
MATERIALS ABATEMENT.
2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXTERIOR WINDOW TRIM PAINT.
FILE COPY
Permit No.
PIT1 review approval is subject to errors and omissions.
of construction documents does not authc'j:73
ton of &ny adopt e or ordinance. Receipt
Lwrov d Cop is acknowledged:
City Of lbkwIla
BUILDING DIVISION
THERMOSTAT/SWITCH HOURS OF OPERATION
SET THERmosTAT/swiTcH TO OPERATE 1 OF EVERY 2 HOURS.
RECEIVED
CITY OP TUKWILA
JAN 0 7 2013
pFmtio-cENTEp
MECHANICAL VENTILA I
ON
CALCULATION
PER WAC
51-51 M1508,3:
QF = QR / (&EGR X F)
QR = (FROM TABLE M1508.2) 45.
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION
F = FRACTION OF OPERATION /2
QF = 45 / (1 X 1/2) = 90 CFM
F SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 1 4 .,n,r)
A-7
City of Tukwila
BUILDING DIVISION
M
EXPIRES: 9/08/2012
2.
S.M. STEMPER
ARCHITECTS
kftWestsionalUmilodUabiftrftimmy
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, "ITA 08100
000 624-2777 ^ (ooe) 024-2973
THE GREENBUSCH GROUP, INC
)))
ritEMPALIAIRIVRETILTENEC2riallF.Eligingi
10417/78-0562 (206) 378-0541 FM
0810.032227
RESIDENTIAL AIR
AIP NUMBER
3-53-0058-044
DATE
06/05/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M .0
0810.03.2227
7"0 UP
ROUTE OVER
BEAM
T0GE
I I
7"0
LOWER FLOOR M
SCALE: lye = r -o»
BEAM
3
FURNACE
.PLAN
CEILING
JOIST
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
VOLUME DAMPER FOR
EXISTING RETURN DUCT.
FIELD VERIFY SIZE
PRIOR TO ORDERING
MOD, INTERLOCK
TO FURNACE
POC
FLOOR
FURNACE
SCALE: NONE
EL
EVATION
SOFFIT, REFER TO
ARCHITECTURAL
MAIN FLOOR MECHA
SCALE: := i' -O"
SHEETMETAL
TRANSITION TO WALL
CAP NECK SIZE
N
ICAL PLAN
DUCT PER PLAN
CAULK
2X BLOCKING
NOTES:
2X BLOCKING
FOAM BACKER
ROD
WALL CAP
SLEEVE AND
ESCUTCHEON
WALL
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS,
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORD. W/ARCHITECTURAL TECHNICAL DOCUMENTS,
REF. 1/A2.2 FOR DETAIL.
®WALL CAP DETA
SCALE: NONE
IL
NORTH
DRAW NG NOTES;
1, RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM.
2, FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR
3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51,
SECTION M1508.5.4.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE
TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT
LEAST 8 HOURS A DAY. INDEPENDENT OF CALL FOR HEATING, TO SATISFY
THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51-51, SECTION M1508.5.2
(CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF
OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER
ENERGY -CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH
PROJECT REPRESEN TATI VE.
4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN
COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR
UNIT SYSTEM(S) WITH NEW FILTERS.
FLAG
NOTES:
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO
ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE EXISTING THERMOSTAT AND PROVIDE WSEC 1412.4 COMPLIANT
THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS
"WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC
51-51, SECTION M1508.5,2.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON MI.O.
FIELD VERIFY POC: OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4 FEET
OF FURNACE RETURN INLET PER WAC 51-51SECTION M1508.5.1.
CUT DUCT AND INSTALL A VOLUME DAMPER :ON THE EXISTING FURNACE'
RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE
OUTSIDE/RETURN AIR:: TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR.
FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO. ORDERING. IF A VOLUME
DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED,
REVIEWED FOR
CODE COMPLIANCE
APPROVED
'JAN 14 ,n1.3
City ofTukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWItA
I JAN ,0 7 2013
WIRES: 9/08/201
S.M. STEMPER
ARCHITECTS
A Frafealionall Molted LIA10.114". Camps:iv
4000 DELRIDGE WAY SW
SIM 200 SE41113, WA 90100
(two 024,2777 ^ .PAX (200) II24,297a
THE. GREENBUSCH GROUP, INC
).0 46.4 660
ACOUIRICAL. AUDIO / VIDEO MEOWED& ENGINEERING
IMO REST .N SMELT KEE 101 SOVUE. IR OBIS
(206) 370-0666 (200) 376-0641 FAX
A,IP NUMBER
3-53-0050-044
PATE
08105/2012
ISSUED
100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
4A, DT
MECHANICAL
FLOOR PLANS
AND DETAILS
M2.0
0810.032227