Loading...
HomeMy WebLinkAboutPermit M13-009 - FASANO RESIDENCE - ALTERATIONFASANO RESIDENCE 12029 44 AV S M13-009 City (*Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Inspection Request Line: 206-431-2451 Web site: htto://www.TukwilaWA.aov MECHANICAL PERMIT Parcel No.: Address: 3347400450 12029 44 AV S TUKW Project Name: FASANO RESIDENCE Permit Number: Issue Date: Permit Expires On: M13-009 01/15/2013 07/14/2013 Owner: Name: Address: Contact Person: Name: Address: Email: FASANO MARK P 20208 SE 245TH ST , MAPLE VALLEY WA 98038 SHARYN PARKER 7277 PER E,VE t RD S , SEATTLE WA 98108 SHARYN. PARKER@ KING C OUNTY. G O V Contractor: Name: G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST , PHOENIX AZ 85040 Contractor License No: GGSPEGS919RT Phone: 206 296-7437 Phone: 480 -921 -4079 - Expiration Date: 12/31/2013 DESCRIPTION OF WORK: FRESH AIR SERVICING FOR SOUND REMEDIATION WORK. Value of Mechanical: $595.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie x. with, Fees Collected: $124.25 International Mechanical Code Edition: 2009 Date: V SI 13 ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pres b e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this pe Signature: Print Name: Date: / — � S� 3 within 180 days from the date of issuance,or if the work is This permit shall become null and void if the work is not commencedysuspended or abandoned for a period of 180 days from the last inspection. I1A1 Mel Drin+nrl• PERMIT CONDITIONS Permit No. M13-009 1: ***BUILDING DEPARTMENT CONDMONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Departmenf (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. rinr: IMC -4/1(1 M13-nnq PrintPri• n1-1s-7f1:i e CITY OF TUKWiLA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No.i\)_ ti Project No. Date Application Accepted: Q t Date Application Expires: 01 01 )3 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 3347400450 Site Address: 12029 44th Ave. S. Suite Number: Floor: Tenant Name: Mark Fasano mop Name: Sharyyn Parker, Program Manager Name: Mark Fasano City: Seattle State: WA Zip: 98108 Address: 20208 SE. 245th St. Email: Sharyn.Parker@kingcounty.gov City: Maple Valley State: WA Zip: 98038 CONTACT VERSON - person rercciving all project communication Name: Sharyyn Parker, Program Manager Address: 7277 Permieter Road South City: Seattle State: WA Zip: 98108 Phone: (206)296-7437 Fax: (206)296-7315 Email: Sharyn.Parker@kingcounty.gov New Tenant: ❑ Yes j ..No MECHANICAL. CONTR ACTOR. INEOBMATION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 595.00 Describe the scope of work in detail: Fresh air servicing for sound remediation work. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\Fonns-Applications On Line \2011 Applications'Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to headrefrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/ 1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Signature: Print Name: Jesse Mailing Address: 4000 Delridge Way SW. #200 H:\ ApplicationsTFomts-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Date: V7/I3 Day Telephone: (206)624-2777 Seattle WA 98106 City State Zip Page 2 of 2 City c'Tukwila, Departmeii Community Development 6300 Southcerter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: imp :My ww. ci. tuktvila.iva. us SET RECEIPT RECEIPT NO: R13-00124 Initials: JEM User ID: 1165 Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE) Payment Date: 01/09/2013 Total Payment: 13,045.45 SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT SET TRANSACTIONS: Set Member Amount D13-004 1,018.34 D13-005 1,239.61 D13-006 1,313.36 D13-007 779.67 D13-008 1,116.68 D13-009 1,141.27 D13-010 1,313.36 D13-011 1,092.10 D13-012 1,239.61 D13-013 1,092.10 M13-003 167.70 M13-004 186.50 M13-005 177.10 M13-006 167.70 M13-007 177.10 M13-008 177.10 M13-009 124.25 M13-010 177.10 M13-011 167.70 M13-012 177.10 TOTAL: 17012711- 199, ; 8t8 :3 4- 199, MC • 1I[r TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA TOTAL: ACCOUNT ITEM LIST: Description Account Code 13,045.45 13,045.45 Current Pmts BUILDING - RES 000.322.100 6,849.15 City ct Tukwila, Depa rl meiW Co mmun ity De velopm en t 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: ham./Arww. ci. nikwila.u'a. us STATE BUILDING SURCHARGE 640.237.114 TOTAL: 45.00 13,045.45 �3 l INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proj t: N - s D go,A�� Type of Inspect on: , HdAL. Address: Date Called: Special Instructions: Date Wanted: " p.m Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: �efM` L\i° � 1 CCA-1-i\j Dater REINSPECTION FEE REQUIRD. Prior o next inspection. fee must be paid at 6300 Southcenter Blvduite 100. Call to schedule reinspection. InPector: INSPECTION RECORD Retain a copy with permit A113-001 INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 a (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro'.es. 14k-5. TypeIns�t -..-‘, C l t' S id 6T . A p D\Li Addre s: Tt. Date Called: Special Instructions: DateWanted: -2-9 n m. klmi Requester: Phone No: JApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: --,r--(kf-0 ON(1 -..-‘, C l t' S id 6T . A p D\Li IJo(Jib rf-- - J,W e ,fi Insp ctor: Date:1 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. IPERMIT COORID PLAN REVIEW/ROUTING SLIP 1/ ACTIVITY NUMBER: M13-009 DATE: 01/07/12 PROJECT NAME: FASANO RESIDENCE SITE ADDRESS: 12029 44 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: km) k~Av1/4-C 3 Building Division II Public Works -Ptt cl t\se 0l•'to •i3 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 01/10/13 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 02/07/13 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Pinter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company G a G SPECIALTY CONTRCTORS INC 4809214079 4633 S 36Th Street Phoenix AZ 85040 Out Of State Corporation G & G SPECIALTY CONTRCTORS INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602975812 Active GGSPEGS919RT Construction Contractor 12/31/2009 12/31/2013 General Unused Business Owner Information Name Role Effective Date Expiration Date GOODBALLET, CHARLES ELMER Chief Executive Officer 12/28/2009 Bond Amount WAVY, CHRISTINE Chief Operating Officer 12/28/2009 59BSBEA9058 GOODBALLET, JAMES SCOTT President 12/28/2009 GOODBALLET, TERESA LYNN Secretary 12/28/2009 INS CO OF THE WEST Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 HARTFORD FIRE INS CO 59BSBEA9058 12/18/2010 Until Cancelled $12,000.0001/03/2011 11/16/2012 1 INS CO OF THE WEST 2278440 12/18/2009 Until Cancelled $12,000.00 12/28/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 Companion Property & Cas Ins C PCP10000270101 11/03/2012 11/03/2013 $1,000,000.00 11/16/2012 3 National Union Fire Ins of PA PCP1000027 11/03/2011 11/03/2012 $1,000,000.00 12/27/2011 2 LEXINGTON INS CO 4392611702 12/31/2010 12/31/2011 $1,000,000.0001/11/2011 1 LEXINGTON INS CO 4392611701 12/31/2008 12/31/2010 $1,000,000.0001/14/2010 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 01/15/2013 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUFI CD CFM CIRC CON D CON T COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO N TS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TON TOD TPD TSP TYP V VD VTR WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED : CEILING ABOVE FINISHED FLOOR APPROXI MATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE cownNuATION COORDINATE COLD WATER DEGREE. DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR .ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL :STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER; FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS' GALVANIZED GALLONS PER HOUR GRILLES; REGISTERS; AND DIFFUSERS. GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR HOT WATER HOT WATER 'CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY" INCH KILOWATT, . (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER,: OPPOSED BLADE DAMPER PHASE POINT OF' CONNECTION poyNps=. PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN, GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING, STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE IRESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL voLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE ENGINEERS CONDITIONING NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL XX •OR 2a 0 AsEla X/Y 7////////// 07/WA INE.•••*115 .SMNINNONOMM/ DESCRIPTION DETAIL OR SECTION CAL -LOUT SHEET WHERE SECTION OR DETAIL SHOWN • DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION :OR VERTICAL, DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLANS AND DETAILS GENERAL N..1.0TES. 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE .EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY. BE :SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL :REPRESENTATIVE, COORDINATE THE INSTALLATION WITH .ALL TRADES ,AND GUARANTEE IN 'WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT suBsTiTuTION. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE 4, DIMENSIONS SHCWN FOR DUCTWORK REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH AIRTIGHT. 6. 7. 8. FROM PLANS. WITH INSULATION SHALL BE. NET FREE DIMENSION WITH :INSULATION. INSTALLED. INSULATION SHALL MEET WASHINGTON STATE 'ENERGY CODE (WSEC) CHAPTER 5 503,9 WALLS,: PARTITIONS; CEILINGS AND ROOFING SYSTEMS 'SHALL BE SEALED AIRTIGHT. DUCTWORK, CR STRuCTURAL. COLUMN PENETRATION THROUGH PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE. DUCTS SHALL BE SEALED THE ELECTRICAL CONTRACTOR. ON NE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10.-0* CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3)-0!' CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. HANGERS, SYMBOL Affla SG—X XXX DN D 1 -UPI Sr ....P.M.OPOOPPPONI .,-000.010,•,...0,0,... DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT N DUCT OFFSET DOWN IN FLOW DIRECTION UP VD RA/EA .4,1S1 RIO SA SA -$01— RA/EA SD ><1 0 to - EA DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX .CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURNI AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION — RECTANGULAR TO ROUND • RECTANGULAR ELBOW WITH TURNING VANES SWITCH tiRIO THERMOSTAT EQUIP EQUIPMENT LOCATION MOD', NC NG 101 0 MOTOR OPERATED DAMPER NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUI REMENT MECHANICAL/E L ECTRICAL COORDI NATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCIRIPTION VOLTS PH FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION 23 26 23 26 N/A 23 26 N/A REMARKS MOTOR OPERATED DAMPER 24 1,2 THERMOSTAT 24 X REMARKS: 11 -VERIFY. QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WAC RESIDENCE CODE FLOOR AREA (SQ, FT.) NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810. 03. 2228 2191 2 120 CFM 120 CFM I. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES M1508.2 AND MI508,3 REVISIONS No changes shall be made to the scope of work without prior approval 01 Tukwila Building Division. vIsions will require a new plan submittal end may include additional plan review fees. FILE COPY Permit No. ple,•1 rview approval is subject to errors and omissions. of construction documents does not authorize L. ot my adopted code or ordinance. Receipt rovedweagl•Copy 4 is acknowledged: 1 By Date: - OtyOflbkwlla f BUILDING DIVISION SEPARATE PERMIT REQUIRED FOR: 0 mechanical Eelectrical &Plumbing Geis Piping City of Tukwila BuiLDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 4 Inv) City of Tukwila BUILDING DIVISION .1111•11111.11MIIIMENIM .THERMOSTAT -SWITCH HOURS OF OPERATION.. SET THERMOSTAT/SWITCH TO OPERATE 1 OF EVERY 2 HOURS. RECEIVED enw r Ti ixvintA JAN 07 2013 -)ERMIT CENTER • MECHANICAL. VENTILATION CALCULATION PER WAC 51-51 M1508.3: QF = QR (&EGR X F) QR = (FROM TABLE M1508.2) Q. &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 60 /:(1 X 1/2) = 120 CFM EXPIRES: 9/08/201 S.M. STEMPER ARCHITECTS Professional Lith L&MUty Cup*ny 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, W& 0810S (o) ea4--2777 • FAX 000 824-2278 THE GREENBUSCH GROUP, INC. *0 40 aY+ 041114 ))) 10CriMile1894111111T AUC4D :oatffE 201' 266114,116 206) 376-0569 (200) 378-0641, FM 0810.03.2228 MPROVEMENTS FT NOISE REMED AIP NUMBER 3-53.0058-044 DATE 06105/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULE, ABBREVS., GENERAL NOTES, & DWG INDEX M .0 0810.03.2228 ROOM KITCHEN REAKFAST ROOM EATH (E) DUCTI UP T ROOF CAP STUD( UTLIT LivING ROOM (E)SG MAIN FLOOR MECHANICAL PLAN_ •• SCALE; .1/47 = LLJ FURNACE CEILING. OUTSIDE AR DUCT CONNECTION FLOOR 03 FURNACE ELEVATION SCALE: NONE UPPER FLOOR MECHANICAL PLAN SCALE: lye NORTH. CLOSET cLoSET 5EPROOM 2 REVIEVVED FOR ;ODE COMPLIANCE APPROVED JAN 14 qn45 • DRAWING NOTES: City of Tukwila BUILDING DIVISION 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. RESIDENCE ALREADY HAS OUTSIDE AIR DUCT, MOD AND TIMER SWITCH INSTALLED, 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51, SECTION M1508.5,4, 3.. SEE ELECTRICAL: DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51-51, SECTION MI50EL5i (CONTROLS FOR WHOLE HOUSE "VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM. WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE 4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. FLAG NOTES: REMOVE THE EXISTING THERMOSTAT AND PROVIDE WSEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED; AFFIX A LABEL Tp.. THE CONTROLLER THAT READS "WHOLE HOUSE .VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 5151, :SECTION M1508.5,2. CONTRACTOR TO PROVIDE TESTING AND BALANCING OF EXISTING FURNACE AND DUCTWORK. Msk3%-00 RECent GITV o rt 'Runt 4 IJAN 07 2013 S.M. STEMPER ARCHITECTS Pretesalonal Limited Llabilltiy Camp 4000 DELRIDGE WAY SW SINE 200 . SCATTLE, WA 08106 (e08) 104-2777 ^ FAX (2011) 034-21173 THE GREENBUSCH GROUP, INC ocousinc, moo /, veto. a 11103100112.41 1E0 oar NaMON MEI SUTE 201 261211EDInin (20) 57a-0589 (2135) 3713,-0041 FAX FT NOISE REMEDY IMPROVEMENTS RESIDENTIAL Al RC AIP NUMBER 3-53-0058-044 DATE 06/05/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA DT MECHANICAL. FLOOR PLANS AND DETAILS M2.0 0810.03.2228