HomeMy WebLinkAboutPermit M13-010 - KERR RESIDENCE - ALTERATIONKERR RESIDENCE
3834 S 116 ST
M13-010
City*Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.: 0733000180
Address: 3834 S 116 ST TIIKW
Project Name: KERR RESIDENCE
Permit Number: M13-010
Issue Date: 01/15/2013
Permit Expires On: 07/14/2013
Owner:
Name: HUNTER TED
Address: 3834 S 116TH ST , TUKWILA WA 98168
Contact Person:
Name:
Address:
Email:
Contractor:
Name:
SHARYN PARKER
7277 PERIMETER RD S , SEATTLE WA 98108
SHARYN. PARKER@KING C OUNPY. G O V
G & G SPECIALTY CONTRCTORS INC
Address: 4633 S 36 ST , PHOENIX AZ 85040
Contractor License No: GGSPEGS919RT
Phone: 206 296-7437
Phone: 480-921-4079
Expiration Date: 12/31/2013
DESCRIPTION OF WORK:
FRESH AIR SERVICING FOR SOUND REMEDIATION WORK.
Value of Mechanical: $2,661.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
I hereby certify that I have read and
governing this work will be complie
Fees Collected: $177.10
International Mechanical Code Edition: 2009
Date: U l Ick
d this permit and know the same to be true and correct. All provisions of law and ordinances
ether specified herein or not.
The granting of this permit does not pres
construction or the performance of work.
back of this pe
Signature:
Print Name: v (5 Lcu&y
ThisP ermit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
e to give authority to violate or cancel the provisions of any other state or local laws regulating
I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
Date: / l s- /3
Pi-info/4. n1_1.i_9n11
PERMIT CONDITIONS
Permit No. M13-010
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431-3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
rinr.• IMC -4/1n M13-n1n
Printpri• n1-1s_2n13
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
MECHANICAL
Applications and plans must be
Applications will not
Mechanical Permit No.GTo
Project No.
Date Application Accepted: Ot E: t 13
Date Application Expires: 01 \
(FQr office use only):
PERMIT APPLICATION
complete in order to be accepted for plan review.
be accepted through the mail or by fax.
**please print**
SITE LOCATION
Site Address: 3834 S. 116th St
Tenant Name: Georgina Kerr
PROPERTY OWN,Eii
Name: Sharyyn Parker, Program Manager
Address: 7277 Permieter Road South
Name: Georgina Kerr
Phone: (206)296-7437 Fax: (206)296-7315
Email: Sharyn.Parker@kingcounty.gov
Address: 3834 S. 116th St
City: Tukwila
State: WA
Zip: 98168
CONTACT PERSQN — person receiving all project
communication
Name: Sharyyn Parker, Program Manager
Address: 7277 Permieter Road South
City: Seattle State: WA zip: 98108
Phone: (206)296-7437 Fax: (206)296-7315
Email: Sharyn.Parker@kingcounty.gov
King Co Assessor's Tax No.: 073300180
Suite Number: Floor:
New Tenant: ❑ Yes QI ..No
MECHANICAL. CONTRACTQR Ili QATION
Company Name: TBD
Address:
City: State: Zip:
Phone: Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.:
Valuation of project (contractor's bid price): $ 2661.00/
Describe the scope of work in detail:
Fresh air servicing for sound remediation work.
Use:
Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement ❑
Fuel Type: Electric ❑
Gas 0
Other:
H:\Applications\Forms-Applications On Line12011 Applications\Mechanical Permit Application Revised 8.9-1 I.docx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE : + ' A A I. 1-- ED AGENT:
Signature: v'-..
Print Name: J' e ' olgate Day Telephone: (206)624-2777
Mailing Address: 4000 Delridge Way SW. #200 Seattle WA 98106
Date:
st7A3
H:Wpplications\Fonns-Applications On Line\2011 ApplicationsWechanical Permit Application Revised 8-9-1 I.docx
Revised: August 2011
bh
City State Zip
Page 2 of 2
City
ukwilar
Departmem 'Community Development
6300 Southcerter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http:/4vww.ci.(ukwila.wa.us
SET RECEIPT
D
RECEIPT NO: R13-00124
Initials: JEM
User ID: 1165
Payee:
PAMELA K KUEHL, KING COUNTY (BY PHONE)
Payment Date: 01/09/2013
Total Payment: 13,045.45
SET ID:
S000001897 SET NAME: KING COUNTY NOISE ABATEMENT
SET TRANSACTIONS:
Set Member
Amount
D13-004
D13-005
D13-006
D13-007
D13-008
D13-009
D13-010
D13-011
D13-012
D13-013
M13-003
M13-004
M13-005
M13-006
M13-007
M13-008
M13-009
M13-010
M13-011
M13-012
TOTAL:
1,018.34
1,239.61
1,313.36
779.67
1,116.68
1,141.27
1,313.36
1,092.10
1,239.61
1,092.10
167.70
186.50
177.10
167.70
177.10
177.10
124.25
177.10
167.70
177.10
TRANSACTION LIST:
Type Method Description
Amount
Payment
Credit C VISA
TOTAL:
ACCOUNT ITEM LIST:
Description Account Code
13,045.45
13,045.45
Current Pmts
BUILDING - RES
000.322.100 6,849.15
City c"Tukwila,
Departmei! Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Website: htgx/Srww.ci.tukwila.wa.us
STATE BUILDING SURCHARGE
640.237.114 45.00
TOTAL: 13, 045.45
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 '` (206) 431-3670
Permit Inspection Request Line (206) 431-2451
0(3-.O o
Project: /�
1� F RiR ck F C-,
Type of Inspection:
r I NIA L.—
Address:
L4
irte
Date Called:
Special Instructions:
Date Wanted:.
r-- t 5— 3,
Q-51..
p.m'
Requester:
Phone No:
(958'GtLI-09/D
•
Approved per applicable codes.
Corrections required prior to approval. !�
COMMENTS:
il /
i ('A t" �` a-,sn� 0 FT:i' I it..
•
Inspe qr: '
REINSPEOTION FEE REQUIRED. Prior to
paid a 300 Southcente! Blvd.. Suite 100.
Date:
/ CA—k
S
^.�.
1
nett inspection; feemust be
Call to schedule reinspection:
fERMIT COORD CO4
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: M13-010 DATE: 01/07/12
PROJECT NAME: KERR RESIDENCE
SITE ADDRESS: 3834 S 116 ST
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
4-7 Alti
Bugling Division
Public Works ❑
Fire Prevention
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Comments:
Incomplete ❑
DUE DATE: 01/10/13
Not Applicable ❑
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route Ei
REVIEWER'S INITIALS:
Structural Review Required ❑ No further Review Required ❑
DATE:
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
DUE DATE: 02/07/13
Approved with Conditions 1Se Not Approved (attach comments) ❑
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Contractors or Tradespeople Printer Friendly Page
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name
Phone
Address
Suite/Apt.
City
State
Zip
County
Business Type
G & G SPECIALTY CONTRCTORS INC
4809214079
4633 S 36Th Street
Phoenix
AZ
85040
Out Of State
Corporation
Parent Company G & G SPECIALTY CONTRCTORS INC
UBI No.
Status
License No.
License Type
Effective Date
Expiration Date
Suspend Date
Specialty 1
Specialty 2
602975812
Active
GGSPEGS919RT
Construction Contractor
12/31/2009
12/31/2013
General
Unused
Business Owner Information
Name
Role
Effective Date
Expiration Date
GOODBALLET, CHARLES ELMER
Chief Executive Officer
12/28/2009
Bond Amount
WAVY, CHRISTINE
Chief Operating Officer
12/28/2009
59BSBEA9058
GOODBALLET, JAMES SCOTT
President
12/28/2009
GOODBALLET, TERESA LYNN
Secretary
12/28/2009
INS CO OF THE WEST
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
2
HARTFORD FIRE INS
CO
59BSBEA9058
12/18/2010
Until Cancelled
$12,000.0001/03/2011
11/16/2012
1
INS CO OF THE WEST
2278440
12/18/2009
Until Cancelled
$12,000.00
12/28/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
4
Companion
Property & Cas
Ins C
PCP10000270101
11/03/2012
11/03/2013
$1,000,000.00
11/16/2012
3
National Union
Fire Ins of PA
PCP1000027
11/03/2011
11/03/2012
$1,000,000.00
12/27/2011
2
LEXINGTON INS
CO
4392611702
12/31/2010
12/31/2011
$1,000,000.0001/11/2011
1
LEXINGTON INS
CO
4392611701
12/31/2008
12/31/2010
$1,000,000.0001/14/2010
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
https://fortress.wa.gov/lni/bbip/Print.aspx
01/15/2013
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
SRC
TDM
TOD
TPD
TSP
TYP
VD
VTR
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING.: UNIT
ABOVE FINISHED, CEILING.
ABOVE FINISHED FLOOR
APPROXIMATE.
ARCHITECT
AMERICAN. SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW. FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF' DUCT
BRITISH THERMAL UNITS PER HOUR'
CEILING DIFFUSER
CUBIC FEET PER MINUTE:
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE:
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE:
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR.
GRILLES, ,REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER ,CIRCULAMON:
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY'
INCH
KILOWATT,. (1000 WATTS)
.LEAVING AIR TEMPERATURE
LOW WALL GRILLE-.
LEAVING WATER TEMPERATURE,
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION, ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR. TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER::
PHASE
POINT OFCONNECTION
pouNDs, PER SQUARE INCH.
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLuTIONS. PER MINUTE
SUPPLY :AIR
SEATTLE ENERGY CODE,
SUPPLY ..DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
SEATTLE RESIDENTIAL CODE'
TOTAL DYNAMIC HEAD
TOP OF DUCT.
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VO.LT. VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR
OR a.
DESCRIPTION.
DETAIL OR SECTION cALLouT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION
OF
FLOW'
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
LEGEND,: SCHEDULES, ABBREVIATIONS', GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL FLOOR PLANS. AND DETAILS
GENERAL NOTES
1. THE MECHANICAL i!SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC.:, AND ALL WORK AS IDENTIFIED IN THE. •SPECIFICATIONS.: WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, NTEQRATioN, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN- AND SPECIFIED:. :PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM :COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED, FOR SYSTEM OPERATION.
2. 11 -IE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED Cits1 THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS: ALL SCHEDULED AND SPECIFIED CRITERIA,AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE 'INSTALLATION WITH ALL TRADES AND GUARANTEE IN :WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION,
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE. BEGINNING :CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS,
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION wiTH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9
REQUIREMENTS,
5. DUCTWORK PENETRATIONS 'THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN
AIRTIGHT.
PENETRATION THROUGH
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, .WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10'-0* CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3'-0'. CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
DUCTS SHALL BE SEALED
THE ELECTRICAL CONTRACTOR.
SG X
XXX
ABR
DN +
I -6* -UP +
r
><1
-el-
04'-
$
OR
EQUIP ID#
NG
D
0
DN
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VD
RA/EA
RG
SA
SA
RA/EA
SD
VOLUME DAMPER
RETURN. AIR OR EXHAUST AIR DUCT
RETURN AIR :GRIL.
SUPPLY AIR c.U11Xr, SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING
RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION - RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT :LOCATION.
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE.
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL
ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
DESCRIPTI ON
VOLTS
PH
FURNISHED
UNDER DIVISION
1 NSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
25
26
25
26
N/A
23
26
N/A
REMARKS
BV -I
BLENDING UNIT VENTILATOR
120 •
X
X
X
1,2
SWITCHES (ON, TIMER)
120
X
X
MOTOR OPERATED DAMPER
24
X
X
X
1,2
THERMOSTAT
24
X
X
1
REMARKS
I - VERIFY QUANTITY FROM PLANS (TYP CAL ALL)
2 - DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSI
ONS
ELECTRICAL
WATTS
VOLTS
PHASE:
COMMENTS
BV -1
115
5 WG
521tX12,215WX8-.5"H
76.
120
I, .2, 3
NOTE:
I. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH. THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3.. BASIS OF DESIGN: ALOES. AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE.
MARK
CFM
STATIC.
PRESSURE.
INLET OR NECK.
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
SOA
<'08.' WG
7"
WALL
ALLGRIILLE .
1, 2, 4
.0G-1
90
<.08 WG
7"
7"
WALL
WALL CAP
I, 2, 3., 4
RO-I
or WG
4'
4"
WALL
DECO
I, 2, 4
REMARKS:
I. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
4, BASIS OF DESIGN; ALOES
A. OR APPROVED EQUAL.
5. BASIS OF 'DESIGN: SHOEMAKER
A, OR APPROVED EQUAL.
6. PROVIDE WITH AN OPPOSED BLADE DAMPER
•
WALL CAP SCHEDULE
MARK
LOCATION
CFM
AIR
VELOCITY FPM
STATIC
PRESSURE
S I ZE
REMARKS .
WC
• gATERIQR
90
<, OS"WG
r
1,2
Re::KARM
1. PROVIDE ALL WALL CAPS WITH. INSECT SCREEN
2. BASIS FOR DESIGN: FAMCO HOODED WALL VENT
A. OR APPROVED EQUAL
,EAr4TE PERMIT
REQUIRED FOR:
0 fvlochanicat
Electrical
frPlumbing
Cletras Piping
'I of Tukwila
E . DIVISION
WAC
RESIDENCE CODE
FLOOR AREA
(SQ. FT.)
NUMBER OF
BEDROOMS
CODE REWIRED:
VENTILATION
VENTILATION
PROVIDED
NOTES
001.0,04„.2.229 MOD
1348
2:
90 CFM
90 CFM
08I0032229.,![3:\t4
408
90 CFM
90 CFM.
1„, VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 8.151-15.08, TABLES MI508.2 AND M1508.3
MINIMUM DUCT INSULAT
ON THICKNESS
DUCT LOCATION
VLL1E
NOTES.
ON ROOF :OR:: ON EXTERIOR CF BUILDING
R-8 WITH WEATHERPROOF BARRIER
L3
ATTIC, GARAGE. CRAWL SPACE. IN WALLS. IN FLOOR/CEILING
R-8
1,2.3
VViTHINKONDITIONED.SPACE OR IN HEATED EASEMENTS:
R-8
ENLOEMENT,SLA$ OR IN GROJM
R-5
.3
NOTES:
I, THICKNESS OF INSULATION 15 DEEINED AS THE. THICKNESS : OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE On 7TED. ON THAT PORTION OF A: DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE WHERE BOTH SIDES: OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR.
3. REFER TO WASHII4GTON STATE ENERGY CODE FOR ADDITIONAL IREQUIREMENTS,
RAVING NOTES:
1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXTERIOR WINDOW TRIM PAINT,
FILE COPY
Permit No.
Pter rview approval is subject to errors and omissions.
ot: construction documents does not autire
cl Lrey adopted code or ordinance. Race!pt
oi aeveo FI-tt' Cop t •II i. 4
-..
t q • : is acknowledged:
By
Date: 15- 13
City Of Tukwila
BUILDING DIVISION
THERmosTAT/swt'TQK
HO.0
RS OF OPERATION
SET FURNACE THERMOSTAT/SINITCH TO OPERATE 1 OF EVERY 2 HOURS.
SET BV -1 SWITCH TO OPERATE 1 OF EVERY 3 HOURS.
RECEIVED
Clrf OF TtisaAnLA
JAN 0 7 2013
PERMIT CENTER
FU
RNACE
MEC
HANICAL VENTILATION CALCULATION
PER WAC 51-51 M1508.3:
QF = QR (&EGR X F)
QR = (FROM TABLE M1508.2) /5,
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION
F = FRACTION OF OPERATION IA
QF 45 / (1 X 1/2) = 90 CFM
F SYSTEM OPERATES 1 OF EVERY 3 HOURS) =
BV -1
MECHA
NIC..AL VENTILATION CALCULATION
PER MC 51-51 M1508.3:
OF = OR / (&EGR
QR = (FROM TABLE M1508.2) Q.
&EGR VENTILATION :EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) =: 1
F = FRACTION OF OPERATION La
QF = 30 / (1 X 1/3) = 90 CFM
REVISIONS
19,1 r"hanges shall be made to the scope
rnrk without prior approval of
7; !zwila Building Division.
(717, '',V;:i1Ortri will require a new plan submittal
cn.imay inr,::ude additional plan review fees.
REVIEWED FOR
COub cumPLiANch
APPROVED
JAN 1 4
City of Tukwila
BUILDING DIVISION
M14)
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Profeadoael ihnited L1bUI Courpeny
4000 DEIRIDGE WAY SW
SUITE 200 - SEATTLE, WA 0000
(000) 824-2r/7 • PAX (208) 824-2V72
THE GREENBUSCH GROUP, INC
ea 8**
)))
raeor. icki.‘Ammo arE, In 201 SIMILE.* OA
(20e) 3711-0569 (208) 370,0641 FAX
MPROVEMENTS
FT NOISE. REMED
RESIDENTIAL AIRC
AIP NUMBER
3-53-0058-044
DATE
06/05/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG1NDEX
M .0
0810,03222.9
rig
UP INTO
JOIST BAY
1
-----'-\\(\\E) RETURN
HOLD TIGHT TO
FLUE
LOWER FLcC.R MEPK.A.
SCALE: 1/4 -
w
FURNACE
c\
PLAN NORTH
CEILING
OUTSIDE AIR DUCT,
SIZE AND ROUTE IN
JOIST PER PLAN
— VOLUME DAMPER FOR
EXISTING RETURN DUCT,
FIELD VERIFY SIZE
PRIOR TO ORDERING
MOD, INTERLOCK
TO FURNACE
FURNACE ELEVATION
SCALE: NONE
POC
(E) FILTER
FLOOR
KITCHEN
piNNa
ROOM
/BATH
MAIN FLOOR
SCALE:: 1 /4".
M
ATTIC
RETURN AIR
DUCT
OUTSIDE AIR
HOLD TIGHT TO
STRUCTURE
MOTOR ACCESS
FILTERS ACCESS
SUPPLY DUCT
DUCT
(L)
SUPPLY DUCT
ECHANICAL PLAN NO0RTH
NOTES:
1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
3. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS
HATCH WITH TECHNICAL REPRESENTATIVE
BV -1 INSTALLATION DETAIL
SCALE: NONE
SHEETMETAL
TRANSITION TO WALL
CAP NECK SIZE
DUCT PER PLAN
CAULK
2X 'BLOCKING
NOTES:
INSTALL SUPPLY GRILL
LOW ON THIS WALL.
INSTALL RETURN GRILL
HIGH ON THIS WALL
T)
...... ....... FLOOR tittECHANICAL: ........ PLAN NORTH
SCALE: 1/4" =:
2X BLOCKING
•FOAM BACKER
ROD
WALL CAP
SLEEVE AND
ESCUTCHEON
WALL
1. 'INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCAMONS.
3. COORD. W/ARCHITECTURAL TECHNICAL DOCUMENTS,
REF. 1/A2.2 FOR DETAIL.
WALL CAP DETAIL
SCALE: NONE
CAULK
SHEETMETAL
TRANSITION TO
GRILLE NECK SIZE
2X BLOCKING
FOAM BACKER
ROD
WALL GRILLE
DUCT PER. PLAN
2X BLOCKING
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL PER MANUFACTURER'S WRifltNI INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATION'S.
3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
WALL GRILLE DETAIL
SCALE: NONE
DRAWI
NG: NOTES:
1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM.
2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY
OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51,
SECTION M1508.5.4.
3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE
TIME OF FINAL INSPECTION,: THE WHOLE HOUSE FAN SHALL OPERATE FOR
AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL. FOR HEATING, TO.
SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER SECTION
M1508.5.2 (CONTROLS :(ooNTRo4s FOR wkipt.E HOUSE vps1TkATioN. SYSTEMS SHALL BE
CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING
OTHER ENERGY -CONSUMING APPLIANCES). COORDINATE FINAL 11ME SETTING
WITH: PROJECT REPRESENTATIVE.
4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN
COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR
UNIT SYSTEM(S) WITH NEW FILTERS.
FLAG. NOTES:.
CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER
TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS.
REMOVE THE. EXISTING THERMOSTAT ANo. PROVIDE -wsEo141z4
COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE
CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING.
INSTRUCTIONS)"PER WAC 51,51, SECTION M1508.5.2. COORDINATE FINAL
SWITCH LOCATION WITH ''HOMEOWNER,
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN 4
FEET OF FURNACE RETURN INLET PER WAC 51-51, SECTION M1508.5.1.
CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE
RETURN AIR DUCT. VOLUME -DAMPER SHALL ALLOW FOR BALANCING THE
OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE
AIR, FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING. IF A
VOLUME DAMPER EXISTS IN THIS LOCATION, IT MAY BE REUSED.
'$V-1 AND DUCTWORK ROUTED IN STORAGE. COORDINATE ELECTRICAL 'AND-
MAINTENANcE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE
ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL
SPECIFICATIONS SECTION 16100. AFFIX A LABEL TO THE CONTROLLER
THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)"
PER WAC 51-51, SECTION M1508.8.4.
TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE
MAKING FINAL GRILLE OR DIFFUSER CONNECTION.
MAIN
• LOWER
t'tISO1O
KEY TO VENT
NONE
UPPER
MOD
B V— 2
RECEIVED
CITY OF TUKWILA
JAN 07 2013
PERMIT CENTER
LATION ZONES NORTH
REVIEWED FOR
CODE COMPLIANCE
APPROVED
JAN 1 4
City of Tukwila
BUILDING DIVISION
EXPIRES: 9/08/2012
S.M. STEMPER
ARCHITECTS
A Protaxdonal Limited LiabU1 Ompasky
4000 DRINDGE WAY .SW
SUITE 200 •• SHAMA WA 28106
(SOO 024-2777 ^ FAX (206) 6244:v6
THE GREENBUSCII GROUP, INC
ACOUSTICAL. .AU010: / SICSO& LIECHNICAC ENOINEERINO
!ISIXI WEST Mao '.:!SITINEET SUITE let SEP= VA CIO
(206) 5711011112 (206) 3760641 FAX
NTERNATIONAL AIRPORT
AM NUMBER
3-53-0058-044
DATE
06/06/2012
ISSUED 100°A CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
MECHANICAL
FLOOR. PLANS
AND DETAILS
M2.0
0810.03.2229