Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-011 - NGUYEN AND DIEM RESIDENCE - ALTERATION
NGUYEM & DIEM RESIDENCE 11620 40 AV S M13-011 City (111? Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 7340600123 Address: 11620 40 AV S TUKW Project Name: NGUYEN AND DIEM RESIDENCE Permit Number: M13-011 Issue Date: 01/15/2013 Permit Expires On: 07/14/2013 Owner: Name: NGUYEN HAI T+DIEM DUNG PHAM Address: 11620 40TH AVE S , SEATTLE WA 98168 Contact Person: Name: Address: Email: Contractor: Name: SHARYN PARKER 7277 PERIME ER RD S , SEATTLE WA 98108 S HARYN. PARKER@KING C O UNTY. G O V G & G SPECIALTY CONTRCTORS INC Address: 4633 S 36 ST , PHOENIX AZ 85040 Contractor License No: GGSPEGS919RT Phone: 206 296-7437 Phone: 480-921-4079 Expiration Date: 12/31/2013 DESCRIPTION OF WORK: FRESH AIR SERVICING FOR SOUND REMEDIATION WORK. Value of Mechanical: $1,673.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied The granting of this permit does not pres construction or the performance of work. back of this pe Signature: Print Name: 0 Q Fees Collected: $167.70 International Mechanical Code Edition: 2009 Date: d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: — /S. ( 3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. • • PERMIT CONDITIONS Permit No. M13-011 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. rine IMC -4/10 M13-011 PrintM M-15-9(113 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://wwvv.TukwilaWA.gov Mechanical Permit No. t,171A, k Project No. Date Application Accepted: 01 11 Data Application Expires: z b`1 V (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 11620 40th Ave. S. Tenant Name: Hai Nguyen and Pham Diem PROPERTY OWNER Name: Sharyyn Parker, Program Manager Name: Hai Nguyen and Pham Diem City: Seattle State: WA Zip: 98108 Address: 11620 40th Ave. S. Email: Sharyn.Parker@kingcounty.gov City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Sharyyn Parker, Program Manager Address: 7277 Permieter Road South City: Seattle State: WA Zip: 98108 Phone: (206)296-7437 Fa": (206)296-7315 Email: Sharyn.Parker@kingcounty.gov King Co Assessor's Tax No.: 7340600123 Suite Number: Floor: New Tenant: ❑ Yes J ..No MECII.ANCAL CONTRACTOR INP TION Company Name: TBD Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Fresh air servicing for sound remediation work. Use: Residential: New ❑ Replacement ❑ Commercial: New 0 Replacement 0 Fuel Type: Electric ❑ ou Gas ❑ Other: H:Wpplications\Porms-Applications On Line\20I I Applications\Mechanical Permit Application Revised 8-9-1I.docx Revised: August 2011 bh Page 1 of 2 4. Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNERENT: Signature: Print Name: Jesse Holgate Mailing Address: 4000 Delridge Way SW. #200 H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9.11.docx Revised: August 2011 bh Date: V7// Day Telephone: (206)6x24-2777 Seattle WA 98106 City State Zip Page 2 of 2 City aukwilar Department of Community Development 6300 Southcerter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: hltp:/Svivx.ci.rukwila.wa.us SET RECEIPT RECEIPT NO: R13-00124 Initials: JEM Payment Date: 01/09/2013 User ID: 1165 Total Payment: 13,045.45 Payee: PAMELA K KUEHL, KING COUNTY (BY PHONE) SET ID: S000001897 SET NAME: KING COUNTY NOISE ABATEMENT SET TRANSACTIONS: Set Member Amount D13-004 1,018.34 D13-005 1,239.61 D13-006 1,313.36 D13-007 779.67 D13-008 1,116.68 D13-009 1,141.27 D13-010 1,313.36 D13-011 1,092.10 D13-012 1,239.61 D13-013 1,092.10 M13-003 167.70 M13-004 186.50 M13-005 177.10 M13-006 167.70 M13-007 177.10 M13-008 177.10 M13-009 124.25 M13-010 177.10 M13-011 167.70 M13-012 177.10 TOTAL: 1-70-11714— 1291 MCj4C TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 13,045.45 TOTAL: 13, 045.45 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES 000.322.100 6,849.15 CityTukwila, DeP f nrtnrerrrO Cornnrrurit Dev Y eloper ear t 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: /tun .14v ww.ci-nikwila.Ira. us STATE BUILDING SURCHARGE 640.237.114 45.00 TOTAL: 13,045.45 INSPECTION RECORD Retain a copy with permit INSPECTIO(J NO. PERMIT NO.�4 CITY``OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 p _ (206) 431-3670 Permit Inspection Request Line (206) 431-2451 1'� Mt3-0t( Proje�ct:: & fl IVuyw &eS:den AddrIi(0ZD 4 AVS Special Instructions: Type ion: K- OUt(2i/4- LOU i(t df Date C Iled) Date Wanted /3 ek_m,) p.m. Requester: Phone No: © Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: f) e]►An—c p 17 .. e l n d n Inspector: Date t U /1 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. •PERMIT COORD COP" PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-011 DATE: 01/07/12 PROJECT NAME: NGUYEN & DIEM RESIDENCE SITE ADDRESS: 11620 40 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: uilding Division Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Comments: DUE DATE: 01/10/13 Not Applicable ❑ Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials: TUESITHURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 02/07/13 Approved ❑ Approved with Conditions W Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Printer Friendly Page 1 1 General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company G & G SPECIALTY CONTRCTORS INC 4809214079 4633 S 36Th Street Phoenix AZ 85040 Out Of State Corporation G a G SPECIALTY CONTRCTORS INC UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 602975812 Active GGSPEGS919RT Construction Contractor 12/31/2009 12/31/2013 General Unused Business Owner Information Name Role Effective Date Expiration Date GOODBALLET, CHARLES ELMER Chief Executive Officer 12/28/2009 Bond Amount WAVY, CHRISTINE Chief Operating Officer 12/28/2009 59BSBEA9058 GOODBALLET, JAMES SCOTT President 12/28/2009 GOODBALLET, TERESA LYNN Secretary 12/28/2009 INS CO OF THE WEST Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 HARTFORD FIRE INS CO 59BSBEA9058 12/18/2010 Until Cancelled $12,000.0001/03/2011 11/16/2012 1 INS CO OF THE WEST 2278440 12/18/2009 Until Cancelled $12,000.0012/28/2009 12/27/2011 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 4 Companion Property & Cas Ins C PCP10000270101 11/03/2012 11/03/2013 $1,000,000.00 11/16/2012 3 National Union Fire Ins of PA PCP1000027 11/03/2011 11/03/2012 $1,000,000.00 12/27/2011 2 LEXINGTON INS CO 4392611702 12/31/2010 12/31/2011 $1,000,000.0001/11/2011 1 LEXINGTON INS CO 4392611701 12/31/2008 12/31/2010 $1,000,000.0001/14/2010 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period https://fortress.wa.gov/lni/bbip/Print.aspx 01/15/2013 ABBREVIATIONS L EGEND DRAWING INDEX ACM ACU AFC AFF APPROX. ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV. EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG .HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO N TS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM •SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING: UNIT ABOVE FINISHED- CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN: SOCIETY OF HEATING, REFRIGERATION AND AIR :CONDITIONING] ENGINEERS BELOW •FINISHED - :CEILING BELOW FINISHED, FLOOR BOTTOM: OF DUCT BRITISH THERMAL UNITS - PER OUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE: DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR .ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE: ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, .REGISTERS„ AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEA11NGI VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY' INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTEC11ON ASSOCIATION NATURAL GAS NORMALLY ()FEN' NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE :DAMPER. PHASE POINT OFCONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP' SPECIFICATIONS SEATTLE RESIDENTIAL. CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE, CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATI ONS LISTED SYMBOL OR XX, 0 X/Y ABBR DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE ,1•••••••••••••••••••MIS DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL. DIMENSION Y ELEVATION OR VERTICAL. DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL FLOOR PLAN AND DETAILS M2.1 MECHANICAL FLOOR PLAN - GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN. OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS. LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE 'SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS: ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE: COORDINATE THE INSTALLATION 'W111 -I ALL TRADES AND GUARANTEE IN 'wpm:NG THAT NO :ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION: OR ORDERING EQUIPMEN.T, DO NOT SCALE. -FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET WASHINGTON STATE ENERGY CODE (WSEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS. PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE TEL OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10.-0* CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL SG—X XXX AMR + I + 1><1 -10E- 4H4- 0'4 DN UP VD RA/EA RG SA SA RA/EA SD DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR AT11C DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN] AIR OR EXHAUST :AIR' DUCT REwRN AIR mug SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE. TRANSITION — RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH ino OR el THERMOSTAT ,EQUIPLOCATION NG 74 • WA' MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE piPE/DuCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE. APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL/ELECTRICAL COORD NATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT DESCRIPTI ON VOLTS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION 23 26 23 26 N/A 23 26 N / A REMARKS MOTOR OPERATED DAMpE_R. 24 X 1,2 THERMOSTAT 24 X X X REMARKS: VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH WALL CAP scHE1-.)..o.L. MARK LOCATION CFM AIR VELOCITY FPM STATIC PRESSURE SIZ.E. REMARKS. WC - EXTERIOR 120 440 <.orwG r0: 1,2 REMARKS; PROVIDE ALL WALL CAPS WITH INSECT SCREEN 2. BASIS FOR DESIGN:. FAMCO HOODED WALL VENT A. OR APPROVED EQUAL WAC RESIDENCE CODE FLOOR AREA. (SQ. FT.) NUMBER OF BEDROOMS CODE REQUIRED. VENTILATION VENTILATION PROVIDED NOTES 0810.03.2230 2.426 2 120 CFM 120 CFM I. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE ,(WAC), SECTION 51-51-1508, TABLES MI508.2 AND. MI50.8.5: SEPARATE PERMIT REQUIRED FOR: IVkichanical bectrical dumbing Gets Plping C•:y of Tukwila Bloc k -,.1G DIVISION M I NI MUM DUCT INSULATION - THICKNESS DUCT LOCATION MIN VALUE 1 NOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1.5 ATTIC. GARAGE, CRAWL ::SPACE:.. IN WALLS. IN FLOOR/CEILING R-8 2, WITHIN CONDITIONED SPACE OR IN HEATED BASEMENTS. R-8 1.3 IN CEMENT SLAB OR tN GROVNID R-5 1.3 NOTES; I. THICKNESS OF 1NSULATIO4 IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING 'FINISHING MATERIALS. 2. INSULATION MAY RE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOORICEILING. 'SPACE WHERE BOTH SIDES OF THIS SPACE ARE :EXPOSED TO UNCONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR, .3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWN G NOTES: 1. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT, REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. TM: flovisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No. rsti3e.oti FIr rpview approval is subject to errors and omissions. of constructon documents does not autticte .ton oiany adopted code or ordinance. Receipt Loprov,-- • AI Cop : is acknowledged: By Date: City Of llikwita BUILDING DIVISION THERMOSTAT/SWITCH HOURS OF OPERATION SET THERMOSTAT/SWITCH TO OPERATE 1 OF EVERY 2 HOURS. RECEIVED env OF TUKWILA I JAN 07 2013 PERMIT CENTER N1ECHANIC.AL. VENTILATION CALCULATION PER WAC 51-51 M1508.3: QF = QR / (&EGR X F) QR = (FROM TABLE M1508.2) EQ. &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 60 / (1 X 1/2) 120 CFM REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 4 2013 VIAL 4 -)City of Tukwila BUILDING DIVISION ExPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS k Professional WaitedLIibdIit Comm4000 DELRIDGE WAY SW sum 200 SEATTLE. WA 081011 ONO 694-2777 ^ FAX (2O) e24 - THE GREENBUSCH GROUP, INC ) ) ) 0 11,11i 0 Ili et • * • led SIMINKERSO‘linT AUC4D SES In 201 SEAM& IR COI (2o6) 378-05459 (20e) 3711-41041 FAX C Q CO 0 0 t"4"E 0 0 FT NOISE REMEDY IMPROVEMENTS RESIDENTIAL AIR AIP NUMBER 3-53-0058-044 DATE 06/05/2012 ISSUED 100% CD. PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, 84. DWG INDEX M1 .0 0810.03.2230 (E)SG DEN IBAT1-4 (E)EG 1 LAUNDRY FAM I LY ROOM (E)SG, 22 X, 30'.EXIT. ATTIC ACCESS PANEL (ORO (E) RETURN UP, OA CONNECTION MADE IN ATTIC, SEE M2.1 BATH 2 (E)SG (E)SG EiE1:3 ROOM 2 KITCHEN ID !WING ROOM Ads': MAIN FLOOR MECHANICAL PLAN NORTH SCALE 1/4" = 1i-0" EXTEND HARD DUCT AS NECESSARY TO INSTALL OA CONNECTION AND VOLUME DAMPER OUTSIDE AIR DUCT, SIZE AND ROUTE IN JOIST PER PLAN VOLUME DAMPER FOR EXISTING RETURN DUCT, FIELD VERIFY SIZE PRIOR TO ORDERING FLUE z. w MOD, INTERLOCK TO FURNACE POC ,1\ FURNACE ATTIC FLOOR FURNACE ELEVATION SCALE: NONE SHEETMETAL TRANSITION TO WALL CAP NECK SIZE DUCT PER PLAN CAU LK 2X BLOCKING NOTES: 2X BLOCKING FOAM BACKER. ROD WALL CAP SLEEVE AND ESCUTCHEON WALL 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORD. W/ARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL WALL CAP DETAIL SCALE: NONE DRAWING NOTES: 1. RESIDENCE IS FULLY CONDITIONED BY A DUCTED FURNACE SYSTEM. 2. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51, SECTION M1508.5.4. 3. SEE ELECTRICAL DOCUMENTS FOR FURNACE WIRING MODIFICATION. AT THE TIME OF FINAL INSPECTION, THE WHOLE HOUSE FAN SHALL OPERATE FOR AT LEAST 8 HOURS A DAY, INDEPENDENT OF CALL FOR HEATING, TO SATISFY THE WASHINGTON ADMINISTRATIVE CODE, CHAPTER 51-51, SECTION M1508.5.2 (CONTROLS FOR WHOLE HOUSE VENTILATION SYSTEMS SHALL BE CAPABLE OF OPERATING THE VENTILATION SYSTEM WITHOUT ENERGIZING OTHER ENERGY -CONSUMING APPLIANCES). COORDINATE FINAL TIME SETTING WITH PROJECT REPRESENTATIVE. 4. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. FLAG NOTES: REMOVE THE EXISTING THERMOSTAT AND PROVIDE WSEC 1412.4 COMPLIANT THERMOSTAT AS SPECIFIED. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51, SECTION M1508.5.2. FIELD VERIFY POC OF OUTSIDE AIR DUCT TO (E) FURNACE IS WITHIN '4 FEET OF FURNACE RETURN INLET PER WAC 51-51, SECTION M104,51... CUT DUCT AND INSTALL A VOLUME DAMPER ON THE EXISTING FURNACE RETURN AIR DUCT. VOLUME DAMPER SHALL ALLOW FOR BALANCING THE OUTSIDE/RETURN AIR TO PROVIDE THE SCHEDULED VOLUME OF OUTSIDE AIR. FIELD VERIFY RETURN AIR DUCT SIZE PRIOR TO ORDERING, IF A VOLUME DAMPER EXISTS IN THIS. LOCATION, IT MAY BE REUSED. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 4 2013 City of Tukwila BUILDING DIVISION RECEIVED crry OF TUKW !JAN 07 20131 ?PERMIT CENTER EXPIRES: 9/08/2012 S.M. STEMPER ARCHITECTS Profeialonal Limited LiA14110 Compaq 4.000 0ELRIDGE WAY SW MATE 200 • SEATTLE, WA 08100 (20) 024-2777 ^ par (2043) 8214-2e THE GREENBUSCH GROUP, INC 00.404046*.111 ACOUSlICAL. AUDIO / MOM Ss 111111WACIL EIXIINEERIN¢ 1000 WEST NOMN SMELT NOE 201 SOME. VA OM (2045) 376-0S05 (205) 375-0041 FAX 0810.03.2230 FT NOISE REMEDY IMPROVEMENTS AIP NUMBER DATE 3-53-0058-044 06/05/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL FLOOR PLAN AND DETAILS M2.0 0810.03.2230 —1 17 — II Li u — --,— -- I1 I1 11 II IIj II 1 I 22' x 3 E I T.® ( 1 ATTIC ACCESSi fv. PANEL I = 1 1 111 11 1 I L�� ATTIC MECHANICALPLAN • SCALE: 1 /.4" 1 — 1 LJ 7" n — 11 L]. n 75 SEE T FLAG NOTES: CUT AND PATCH STUD WALL AS REQUIRED TO INSTALL WALL CAP. REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 14 2013 City of Tukwila BUILDING DIVISION .0 ti RECEIVED CR'vOFTtIW WIRA I JAN 0 7 2013 PERMIT CENTE4 EXPIRES 9/08/2012 S.M. STEMPER ARCHITECTS A Professional. Malted fdrbll kr Conway 4Q00 11ELGE WAX SW SUITE 200 • SEATTLE, WA 08100 (206) 824-2777 • :PAR (208) 884-227e THE. GREENBUSCH GROUP, INC 400 AP AO0US1�1, AUOIO i0000& f�clulerx 120014201010 1000 .STI EEf SUITE 101 StAME.1r111A811Y (20.5) 575—Cee2 (200). 875-0041 FAX 0810. 032230 0 CL Ct C7 0 0 ct 0 ct 0 ce 0 AIP NUMBER 3-50-0058-044 DATE 06/05/2012 ISSUED 140%o CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL FLOORL M2.1 1 3 22.3 .