HomeMy WebLinkAboutPermit M13-016 - NORDSTROM - ALTERATIONNORDSTROM 100 SOUTHCENTER MALL M13-016 City oftukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 100 SOUTHCENTER MALL TUKW Project Name: NORDSTROM Permit Number: M13-016 Issue Date: 01/22/2013 Permit Expires On: 07/21/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: KAREN GEORGE Address: 9322 14 AV S , SEATTLE WA 98108 Email: KGEORGE@PSFMECH.COM Contractor: Name: Address: Contractor License No: Phone: 206-812-7678 Phone: Expiration Date: DESCRIPTION OF WORK: INSTALL (1) NEW FIT BOX, GRD'S AND DEMO Value of Mechanical: $98,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Fees Collected: $1,289.06 International Mechanical Code Edition: 2009 Permit Center Authorized Signature: � 9' " Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: X;9-rEi'I J6-02 /' 9� Date: I —.C3C9 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. •inn n4c f.:..4..A• AA nn ^311,11 PERMIT CONDITIONS Permit No. M13-016 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. �1nr. IMC -4/1 t1 M13 -01R Printprl• 01-99-9M3 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 htto://www.citukwila.wa. us MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 9202470160 Site Address: 100 Southcenter Mall Suite Number: Floor: 1 , 2 13 New Tenant: 0 Yes ®..No Tenant Name: Nordstrom Property Owners Name: Westfield Property Mailing Address: PO Box 130940 Carlsbad, CA 920T3 City State Zip Name: Karen George Mailing Address: 9322 14th Ave S Day Telephone: 206-812-7678 Seattle City E -Mail Address: kgeorge@psfmech.com WA 98108 State Zip Fax Number: 206-812-7679 Company Name: Mailing Address: PSF Mechanical, Inc. 9322 14th AVe S Seattle, WA 98108 City State Zip Contact Person: Above Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: P S FME I* 0 9 0 N Z Expiration Date: 10-3— 2013 Company Name: Mailing Address: City Contact Person: Day Telephone: E -Mail Address: Fax Number: State Zip Company Name: Mailing Address: Contact Person: E -Mail Address: PSF Mechanical, Inc. 9322 14th AVe S Seattle WA 98108 Lawrence Palmer 1palmer@psfinech.com H:\ Applications\Forms-Applications On Line \2010 Applications\7-2010 - Mechanical Permit Application.doc Revised: 7-2010 bh City Day Telephone: 206-764-9663 Fax Number: State Zip Page l of 2 • • Valuation of project (contractor's bid price): $ 95, 0 00 Scope of work (please provide detailed information): Use: Residential: New 0 Replacement 0 Commercial: New j Replacement ❑ Fuel Type: Electric ❑ Gas 0 Other: Indicate type of mechanical work being installed and the quant'ty below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler/Compressor Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0-3 hp/100,000 btu furnace >100k btu evaporator cooler diffuser //9 3-15 hp/500,000 btu floor furnace ventilation fan connected to single duct thermostat 15-30 hp/1,000,000 btu suspended/wall/floor mounted heater ventilation system wood/gas stove 30-50 hp/1,750,000 btu appliance vent hood and duct emergency generator 50+ hp/1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other mechanical equipment /4" ✓ _ / air handling unit <10,000 cfm incinerator— comm/ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER O AUTHORIZED A ENT: Signature: (24(2.-y Print Name: r(.�- i e C-( .P /' 9 Mailing Address: //' 7" - J.P $ Date: / ' /171— / Day Telephone: tiro 8/.) - 76 7 .2 ,L7L4a tv/e) 9'J City State Zip Date Application Accepted: `_ t u Date Application Expires: -7 _ Staff Initials: vw H:\Applications\Forms-Applications On Line \2010 Applications\7-2010 - Mechanical Permit Application.doc Revised: 7.2010 bh Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M13-016 Address: 100 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 01/14/2013 Applicant: NORDSTROM Issue Date: Receipt No.: R13-00500 Payment Amount: $1,031.25 Initials: WER Payment Date: 01/22/2013 11:39 AM User ID: 1655 Balance: $0.00 Payee: PSF MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 014911 1,031.25 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 1,031.25 Total: $1,031.25 arinfo,i• n1_11_)n1z • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT ParcelNo.: 9202470010 Permit Number: M13-016 Address: 100 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 01/14/2013 Applicant: NORDSTROM'S Issue Date: Receipt No.: R13-00313 Payment Amount: $257.81 Initials: WER Payment Date: 01/14/2013 04:17 PM User ID: 1655 Balance: $1,031.25 Payee: PSF MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 014909 257.81 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 257.81 Total: $257.81 A_: -.-J. 114 4 , 4,14 q INSPECTION RECORD Retain a copy with permit INSP CTION 0. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Utz_. (206) 431-3670 Permit Inspection Request Line (206) 431-2451 M(3 D Ito Proj ct: a eko Ait Type InnssJpectipn: AJ&� . Address: t 0 d SL M A.1 Date Called: ^ - Special Instructions: / 61 , °Y Date Wanted: _ a.m. -7 -).--if 3 P.m. Requester: Pho a No• 1 i st, � I s,4 3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: P nspector: Datg;_, REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be. paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. `;1It .,y INSP,ECTIC)N RECORD. Retain a copy with permit PERMIT NO. .CITY OF TUKWILA.BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: NORIN�v 12On Type of Inspection: _ ROL(6, � -.1_ ki Address: Date Called: /C/Vs sT 0 Special Instructions: ?i, Date Wanted: a.m. Requester: Phone No: ao•7/G-9X4 ElApproved"per applicable. codes. a Corrections required prior to approval. - COMMENTS: p f /C/Vs sT 0 sw Pe.-- 4s 2—/coIv . /? sr? /sh i ti - 71 Top e ,c.� ---7----"(// vi C�///5"7 A)d5/c/ i frL- "LC( f---70 : ✓,- r Date:7 25— EINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 - (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project Type of Inspection:P'i n Address: Date Called: Special Instructions: Date Wanted:..` (0 — P.m. /3 Requester: Phone No` 11 �q �3 DApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: 2- 3L el 4 I-, .. - , & - Api3%.,h,0 , (ZvA '0•Z_ r._cerci%- w.L- il?,p..10 / .r. t , f' 1 ] .- 1 Datg: no lirr:tA L1 ) NSPECTION FEE RECWIRED. Prior too xt inspection, fee must be id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPEfTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 TZ (206) 431-3670 Permit Inspection Request Line (206) 431-2451 i3 -al Project: Type of Inspection: Duc i_i. Lys JL_ 1\10 R OS Cl/v1 Address: 1(25CD S C nv NI., Date Called: s�� Special Instructions: Date Wanted:. -1%- f7 a.m. Requester: Phone No: g.oG-7r g 8q - ❑Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: 9, /) , ut i.iS c.t0,0,,,,fl1''' - , rte f'` s�� Date: 5 17 - i PEINSPECTION FEE REQUIRED. Prior to plid at 6300 Southcenter Blvd., Suite 100. next inspection, fee must be Call to schedule reinspection. INSPEC ION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OFTUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 %(206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: NURD (2.Ow'1 Type of Inspection: ,r)v' �- ta.... Address: i 0 50. ni A bl, Date Called: Special Instructions: Date Wanted:. a:m. "j -- 1 i-•% - t3 p.m. Requester: Phone No:610---71e97-C1-.5171.7 ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: pi _/- .. ry) 2G. 1' /2 V/ d4 7:o_TA"Sir /MC f Inspecto AAA"- / zo .moi c..rii.JGcs Date:.._-- .. n RAINSPECTION FEE REQ IRED. Prior to next inspection.: fee must be. paid at 6300 Southcenter Blvd.. Suite 100. Call to_schedute reinspection.: INSPECTION RECORD Retain a copy with permit INSPE ON NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 v (206) 431-3670 Permit Inspection Request Line (206) 431-2451 r J .r�lJ�i Project: Type of Inspection: c Address: Lc_C. Ma // Date Called: Special Instructions: Date Wanted:. 3- /3 a.m\ p.m, Requester: 7 3 d- Phone Noe2;"— .5g�,P , / Approved per applicable codes. Corrections required prior to approval. COMMENTS: ic)//,..- )3 •-•560 kii-At -,1.-.0 5S. ).c IP -40".00.1 Zee., i 7 3 d- //..vi- ,&P ‘,/frioe-„5,.,..5. ze-20p 172 4- 7179 ,� /,,4 ..049,6,-,--s04/,%, /17, j ,''r' , 4ic,4 ..f��r� .5, : a, l'-''.-- --� ` "2— 6/..-. -.11 1 A -4 \ REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection: Date: 3 INSPECTION NO. r INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING. DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188' (206):43.1-3670 Permit Inspection Request Line (206) 431-2451 Project: N©at5STi awl Type of Inspection: I'Nd-1 CI 61- r.1 ic4;�� Address: LOO Scr.t%he£iklielz P'1Ail Date Called: — 1 Special Instructions: Date Wanted:. 3— 12..—(3 ` 6m; p.m. Requester: Phone No: Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: I --I /_,L- J 3 v \ r,00, - -i v1/ - vtticl 0 3� u� r\ov }c. PoV— d`'w1k-;W - r/,., , Ispe _Lyt�t-7 r• ic4;�� Da — 1 / REINSPECTION FEE REQUIRED. Pri to next inspection: fee n1ust�be 4aid at 6300 Southcentei Blvd.. Suite 100. Call to schedule reinspection;-. INSPECTION'RECORD Retain a copy with perm t INSPECTION NO, PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100,.jukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 • iO3-e/6 Project: . A4.44)57/2 Type of Inspection: %)Z/�1Nsz/14%701\/ Address: /0/ se cA/7-- rrm e9 // Date Called: Special Instructions: . Date Wanted:. a2--2 6-i3 a.m. Requester: Phone No: �66- -7/8- 96 V3 ElApproved per applicable codes. ElCorrections required prior to approval. %C COMMENTS: e'7`A/(1,7 f'/) a.� \. Inspector: h ,i Date: n REINFECTION FEE R QUIRE . Prior to next inspection, fee must be paidl1at'6300 Southcenter Blvd.,/Suite 100. Call to schedule reinspection. i INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 kia.. (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: &/nr:i fT/ D M Ty of Inspection: IIC 6 , Address:_SC_ � � / w � Date Called: Special Instructions: p -/6/.o �i1 Date Wanted: a.m. Z —Vi —13 (p.m Requester: Phor�eNo: (_-1 (?—(:„ -4 JApproved per applicable codes. Corrections required prior to approval. COMMENTS: 4 1 5 hat ki — ra i\I 1, Flo o 4 c- 'Ss c,,,0 fiR LJ C*77 — D ,A r q LI -\j _ p -/6/.o �i1 / Inspect Date ""ZO rZ 0 fEINSP1ECTION FEE REQUIRED. rior to nex inspection, fee muff be ipaid af 6300 Southcenter Blvd., Suite 100. Ca, to schedule reinspection. ?EiT COs`� PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER:' M13-016 DATE: 01-14-13 PROJECT NAME: NORDSTROM SITE ADDRESS: 100 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Revision # After Permit Issued Response to Correction Letter # EPARTMENTS: ';(3 uilding Division 41 Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 01-15-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route ,tel Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Notation: Approved with Conditions Nf DUE DATE: 02-12-13 Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: " Permit Center Use Only, ., CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople iter Friendly Page 1 General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name P S F MECHANICAL UBI No. 601318369 INC Phone 2067649663 Status Active Address 9322 14Th Ave S License No. PSFMEI'090NZ Suite/Apt. License Type Construction Contractor City Seattle Effective Date 8/9/1991 State WA Expiration 10/3/2013 Date Zip 98108 Suspend Date County King Specialty 1 Heating/Vent/Air-Conditioning And Refrig (Hvac/R) Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EDENN" 225LK EDEN NURSERIES Construction Contractor General Unused 6/12/1978 6/1/1986 Archived Business Owner Information Name Role Effective Date Expiration Date REYNOLDS, JAMES P President 09/30/2011 Bond Amount READ, ANDREW A President 09/30/2011 08973126 BEARDSLEY, WARREN SCOTT Secretary 01/01/1980 CRITCHLOW, JAMES D 09/27/2012 01/01/1980 09/27/2011 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 FIDELITY Et DEPOSIT CO OF MD 08973126 08/08/2009 Until Cancelled $6,000.0007/10/2009 09/27/2012 3 HARTFORDOFIRE INS 528SBFA6327 08/08/2008 Until Cancelled 08/08/2009 $6,000.0007/08/2008 2 FEDERAL INS CO 81241859 08/08/2001 08/08/2008 $6,000.0010/01/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 20 Wausau Underwriters Ins Co TBJZ91452741022 10/01/2012 10/01/2013 $1,000,000.00 09/27/2012 19 Wausau Underwriters Ins Co tbjz91452741021 10/01/2011 10/01/2012 $1,000,000.0009/29/2011 18 WAUSAU UNDERWRITERS INS. CO. TBJZ91452741020 10/01/2010 10/01/2011 $1,000,000.0009/29/2010 17 WAUSAU BUSINESS INS CO TBJZ91452741029 10/01/2009 10/01/2010 $1,000,000.00 10/07/2009 https://fortress.wa.gov/lni/bbip/Print.aspx 01/22/2013 9 J 0 IV IL_ SYMBOLS & ABBREVIATIONS SYMBOL ABBREV. DESCRIPTION SYMBOL ABBREV. DESCRIPTION A.C. AIR CONDITIONING UNIT M.C. MECHANICAL CONTRACTOR A.D. AIR DOOR RET.IEXHUAST FAN MIN OSA CFM POWER MCA WGHT. MD M.D. MOTORIZED DAMPER CFM TSP ESP o A.F.F. ABOVE FINISHED FLOOR (AC -XXX) MECHANICAL EQUIPMENT TAG ESP HP RPM B.D.D. BACKDRAFT DAMPER NOM. NOMINAL (1) B.S. BIRD SCREEN B.O.G. BOTTOM OF GRILLE B.O.D. BOTTOM OF DUCT TO.A. B B.T. BYPASS TIMER Q CENTER LINE CUH CABINET UNIT HEATER ® CO CARBON MONOXIDE SENSOR ® CO2 CARBON DIOXIDE SENSOR 0 DIAMETER D.S. DISCONNECT SWITCH D.T.S. DUCT TEMPERATURE SENSOR /X/X/ 8.5 / // POC _is 1±)01._ '---- R RB O.B.D. OPPOSED BLADE DAMPER ORIFICE SIZE (INCHES) 0.AOUTSIDE AIR OV. OVAL P.B.D. PARALLEL BLADE DAMPER P.O.C, POINT OF CONNECTION R. RELOCATE R.A. RETURN AIR R.B. REBALANCE RAG. RETURN AIR GRILLE R.V.D. REMOTE VOLUME DAMPER - D.G. DOOR GRILLE (FR.V. D- 16,000 0.75 7112 600 (3) OX DRAWING NOTE 4600/3PH/60 •• • :�� RETURN DUCT DOWN 70 KW T.A. FILTERS, 0-100%, ECON. ELECTRONIC CONTROLS (NO T'STATS HIGH CAP. COIL (EVAP), ACCESS DOORS, HIGH EFF. MTRS & E.G.L. AC -2 TRANE I SEHC-504 1ST FLOOR NORTH Jr ,_k... D DUCT DROP IN DIRECTION OF ARROW 2.50 - RETURN DUCT UP 970 (4) 14,500 0.75 5 575 (3) R R ' DUCT RISE IN DIRECTION OF ARROW 167 ►� � SIDE INLET CAN T,A. FILTERS, 0-100%, ECON. ELECTRONIC CONTROLS (NO T'STATS), ACCESS DOORS, HIGH EFF. MTRS & E,G.L. AC -3 TRANE / SEHC604 2ND FLOOR SOUTH 60 25,500 2.00 ROOMS 322, 326; 327. 328,329 & VENDING 25 850 (5) 18,000 DN, DOWN 7112 500 (2) 3000 460U/3PH/60 167 10,000# SD S.D. SMOKE DETECTOR AC -4 E.C.H. ELECTRIC CEILING HEATER 2ND FLOOR NORTH C 24,000 225 E.D.C.C. ELECTRIC DUCT COIL E.F.C. ELECTRIC FAN COIL 25 0 S. DMPR. M KE DAMPER SMOKE O S.P.F. SMOKE PURGE FAN S.S.S.C. SOLID STATE SPEED CONTROL 0.50 E.U.H. ELECTRIC UNIT HEATERjr 470 (2) 3,000 S.L. SOUND LINING 160 10,000# 90 KW T.A. FILTERS, 0-100%. ECON. ELECTRONIC CONTROLS (NO T'STATS), FACTORY CURBS, ACCESS DOORS, HIGH EFF, MTRS & E.G,L. AC -5 TRANE 1 SEHC-504 E.C. ELECTRICAL CONTRACTOR 50 21250 1.75 0.25 20 860 3 () 15 000 0.38 el ELEVATION 2 500 SP. DMPR. SPLITTER DAMPER ROUND 0.25 500# 70 KW T.A. FILTERS, 0-100%, ECON. ELECTRONIC CONTROLS (NO T'STATS), FACTORY CURBS, ACCESS DOORS, HIGH EFF. MTRS & E.G.L, TO ROUND DUCT TRANSITION TRANE I SEHC 504- 3RD FLOOR WEST 50 21,250 SQUARE - EXIST. EXISTING E.A. EXHAUST AIR RECT. SIS START/STOP 0.38 5 540 (3) 2,500 STATIC PRESSURE SENSOR, 133 E.F. EXHAUST FAN 70 KW SP ._. TRANE / BTC 100GV EXT. EXTERIOR OR EXTERNAL S.A. SUPPLY AIR 3,700 0,70 `\ ' `� Jr- e EXTR. EXTRACTOR ,..' r SUPPLY DUCT DOWN (L) 300 460V13PH/60 F.I.T. FAN INDUCTION TERMINAL e O SUPPLY DUCT UP EF -17 AC -8 SQ SW. SWITCH FD F.D FIRE DAMPER 1,200 0.40 - T.C. TEMPERATURE CONTROL 1,100 FSD F.S.D. FIRE/SMOKE DAMPER Q T.S. TEMPERATURE SENSOR 0.25 F.O.B. FLAT ON BOTTOM CT T'STAT. THERMOSTAT 32 F.O.T. FLAT ON TOP - GREENHECK CUE -10-A TOP INLET LAY -IN 940 F.T.U. FAN TERMINAL UNIT T.O.D. TOP OF DUCT jr 11 1 11 4 F.C. FLEXIBLE CONNECTION T.F. TRANSFER FAN KITCHEN HOOD 4,200 3.4 G.C. GENERAL CONTRACTOR 1727 460V/3PH T.V. TURNING VANES EF -21 GREENHECK SP -25 SECURITY HOLD 141 HP -1 TRANE 1 BWC 120C4 3RD FLOOR UPPER WEST LEVEL DOOR 4,000 8x8 NECK SIZE (INCHES) U.D. UNDERCUT 825 (3) - 1' GRILLE, REGISTER, OR DIFFUSER TYPE - 300 200 A 1,108# 29 88KW BAY96x243A W/ OVERSIZED MOTOR, HORIZONTAL DISCHARGE, BAY 28x138 T'STAT V.A.V. VARIABLE AIR VOLUME TERMINAL AIR QUANTITY (CFM) H.P. HEAT PUMP OR HORSEPOWER t --1r V.D. VOLUME DAMPER INT. INTERLOCK M.U.A. MAKE-UP AIR M.U.F. MAKE-UP AIR FAN 1© 1CD1 WIRE GUARD COVER OVER TEMPERATURE SENSOR WIRE GUARD COVER OVER THERMOSTAT EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTIN GENERAL NOTES 1. ALL DUCTWORK SHALL BE INSTALLED IN A WORKMANLIKE MANNER IN ACCORDANCE WITH ALL APPLICABLE CODES AND ORDINANCES: CODES, RULES AND REGULATIONS OF THE STATE OF WASHINGTON, THE CITY OF TUKWILA AND THE UNIFORM MECHANICAL CODE. 2. RECTANGULAR AND ROUND DUCTWORK SHALL BE GALVANIZED SHEET METAL WITH SOUNDLINING OR EXTERNAL INSULATION WRAP AS INDICATED IN NOTE 4 UNLESS OTHERWISE NOTED. 3. FLEXIBLE DUCTWORK SHALL BE CLASS 1 CONFORMING TO U.L. STANDARD 181 AS REQUIRED BY LOCAL CODE OR AGREEMENT. 4. DUCTWORK SHALL BE INSULATED PER THE TABLE BELOW DUCTS REQUIRING INSULATION: A. INDOOR, CONCEALED SUPPLY AND OUTDOOR AIR. B. INDOOR, CONCEALED RETURN LOCATED IN NONCONDITIONED SPACE. C. OUTDOOR, EXPOSED SUPPLY AND RETURN. ITEMS NOT REQUIRING INSULATION: A. METAL DUCTS WITH DUCT LINER OF SUFFICIENT THICKNESS TO COMPLY WITH LOCAL ENERGY CODE. B. FACTORY -INSULATED FLEXIBLE DUCTS. C. FLEXIBLE CONNECTORS. D. VIBRATION -CONTROL DEVICES. E. FACTORY -INSULATED ACCESS PANELS AND DOORS. 5. TAPE OR SEAL ALL JOINTS IN CONCEALED DUCTWORK SYSTEM 6. ALL CUTTING, PATCHING, FRAMING, FIRE SAFING, PAINTING, ROOF OPENING CURBS, ROOFING ETC., REQUIRED TO INSTALL MECHANICAL SYSTEM HEREIN SHALL BE BY GENERAL CONTRACTOR, INCLUDING ALL FLASHING, SEALING, FRAMING AND ROOFING ON SHEET METAL DUCT ENCLOSURES. 7. MECHANICAL EQUIPMENT ACCESS PANELS IN FURRED ENCLOSURES SHALL BE FURNISHED AND INSTALLED BY GENERAL CONTRACTOR. 8. POWER WIRING AND CONNECTIONS TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. CONTROL WIRING AND LOW VOLTAGE CONNECTION TO HVAC EQUIPMENT SHALL BE BY ELECTRICAL CONTRACTOR. 9. ALL EXPOSED ROUND DUCTWORK SHALL BE SPIRAL SHEET METAL. 10. ALL MEDIUM PRESSURE DUCT TO BE MANUFACTURED IN ACCORDANCE WITH SMACNA MEDIUM PRESSURE STANDARDS. 11. BUTTER ALL JOINTS AT SOUNDLINING IN MEDIUM PRESSURE DUCTWORK. 12. ALL MEDIUM PRESSURE DUCT TAKEOFF FITTINGS SHALL BE BOOT TEES UNLESS OTHERWISE NOTED, 13. INLET CONNECTIONS TO ALL MEDIUM PRESSURE SSU E TERMINAL UNITS SHALL HAVE BEAD AND CRIMP TO ASSURE POSITIVE FLEXIBLE DUCT CONNECTION. MINIMUM FLEX DUCT LENGTH SHALL BE THREE FEET UNLESS RESTRICTED BY LOCAL CODE OR AGREEMENT. 14. ELEVATIONS SHOWN ON THESE DRAWINGS ARE INTENDED FOR DESIGN COORDINATION ONLY. REFER TO HVAC SHOP DRAWINGS FOR EXACT ELEVATIONS AND DIMENSIONS. 15. CONTACTORS MAGNETIC STARTERS AND DISCONNECT SWITCHES SHALL BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. 16. DRAWINGS AND MANUALS SHALL BE PROVIDED TO THE BUILDING OWNER IN ACCORDANCE WITH THE 2009 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416. 17. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE BALANCED IN ACCORDANCE WITH THE 2009 WASHINGTON STATE ENERGY CODE WITH SECTIONS 1416.2.3-1416.2.6.3. 18. ALL HVAC SYSTEMS, AIR AND WATER, SHALL BE COMMISSIONED IN ACCORDANCE WITH THE 2009 WASHINGTON STATE ENERGY CODE WITH SECTIONS 141611416:2.3. 19. INSTALL ALL MECHANICAL EQUIPMENT IN ACCORDANCE W/IBC, IMC & SMACNA SEISMIC STANDARDS. 20. PROVIDE PIPE INSULATION PER 14-6 WSEC 21. PROVIDE 5 DEGREE DEADBAND W/ AUTO SETBACK PER WSEC. 22. PROVIDE PREMIUM EFFICIENCY MOTORS FOR ALL MECHANICALSTEM YS S PER WSEC TABLE 14-4. S 23: EQUIVALENTS WILL BE CONSIDERED FOR ALL EQUIPMENT 24. DUCT INSULATION IS SHOWN WHERE REQUIRED BY CODE. INSULATION OUTSIDE OF SHELL AND CORE AREAS SHALL BE PROVIDED AS PART OF THE TENANT IMPROVEMENT PROJECTS. 25. EACH SYSTEM OR ZONE THERMOSTAT SHALL BE CAPABLE OF A DEADBAND OF AT LEAST 5°F WITHIN WHICH THE SUPPLY OF HEATING AND COOLING ENERGY IS SHUT OFF OR REDUCED TO A MINIMUM. 26. MOTORIZED DAMPERS WILL BE PROVIDED TO CLOSE AUTOMATICALLY WHEN IT'S RESPECTIVE SYSTEM IS OFF, OR UPON POWER FAILURE. 27. HEATING AND COOLING SYSTEMS SHALL HAVE OPTIMUM START CONTROLS. 28. AIR ECONOMIZERS SHALL BE CAPABLE OF AUTOMATICALLY MODULATING OUTSIDE AND RETURN AIR DAMPERS TO 100% OF THE DESIGN SUPPLY AIR AS OUTSIDE AIR TO REDUCE OR ELIMINATE THE NEED FOR MECHANICAL COOLING. EXISTING EXISTING EXISTING EXISTING EXISTING. EXISTING EXISTING AC UNIT SCHEDULE MARK MFR. I MODEL AREA SERVED NOM. TON EVAP. FAN RET.IEXHUAST FAN MIN OSA CFM POWER MCA WGHT. AUXIL. ELECT. HT. REMARKS CFM TSP ESP HP RPM CFM ESP HP RPM AC -1 TRANE 1 SERC 554 1ST FLOOR SOUTH 55 22,935 2.50 - 25 990 (4) 16,000 0.75 7112 600 (3) 3,000 4600/3PH/60 160 10,000# 70 KW T.A. FILTERS, 0-100%, ECON. ELECTRONIC CONTROLS (NO T'STATS HIGH CAP. COIL (EVAP), ACCESS DOORS, HIGH EFF. MTRS & E.G.L. AC -2 TRANE I SEHC-504 1ST FLOOR NORTH 50 23,230 2.50 - 25 970 (4) 14,500 0.75 5 575 (3) 3,000 460V13PHI60 167 10,000# 70 KW T,A. FILTERS, 0-100%, ECON. ELECTRONIC CONTROLS (NO T'STATS), ACCESS DOORS, HIGH EFF. MTRS & E,G.L. AC -3 TRANE / SEHC604 2ND FLOOR SOUTH 60 25,500 2.00 ROOMS 322, 326; 327. 328,329 & VENDING 25 850 (5) 18,000 0.50 7112 500 (2) 3000 460U/3PH/60 167 10,000# 90 KW T.A. FILTERS, 0-100113, ECON. ELECTRONIC CONTROLS (NO T'STATS), FACTORY CURBS, ACCESS DOORS, HIGH EFF. MTRS & E.G.L. AC -4 TRANE / SEHC604 2ND FLOOR NORTH 60 24,000 225 1,825 25 850 (5) 16,000 0.50 71/2 470 (2) 3,000 460V/3PH/60 160 10,000# 90 KW T.A. FILTERS, 0-100%. ECON. ELECTRONIC CONTROLS (NO T'STATS), FACTORY CURBS, ACCESS DOORS, HIGH EFF, MTRS & E.G,L. AC -5 TRANE 1 SEHC-504 3RD FLOOR EAST 50 21250 1.75 0.25 20 860 3 () 15 000 0.38 5 540 `3 t } 2 500 460V/3PH/601339 0.25 500# 70 KW T.A. FILTERS, 0-100%, ECON. ELECTRONIC CONTROLS (NO T'STATS), FACTORY CURBS, ACCESS DOORS, HIGH EFF. MTRS & E.G.L, AC -6 TRANE I SEHC 504- 3RD FLOOR WEST 50 21,250 1,50 - 20 810 (3} 15,000 0.38 5 540 (3) 2,500 460UI3PHI60 133 9,500# 70 KW T.A. FILTERS, 0-100°!x, ECON. ELECTRONIC CONTROLS (NO T'STATS), FACTORY CURBS, ACCESS DOORS, HIGH EFF. MTRS & E.G.L, AC -7 TRANE / BTC 100GV CUSTOMER SERVICE 81/2 3,700 0,70 - 3 1,243 - -- DISPLAY WINDOW 133 326 300 460V13PH/60 27 1,300# _ EF -17 AC -8 CARRIER / 50AH024 P.O.S:/TELEPHONE 3 1,200 0.40 - 113 1,100 GREENHECK SP -27 - - 0.25 - 230V/1PH/60 32 500# - GREENHECK CUE -10-A METHANE GAS VENT 940 0.50 1/4 1,725 120V11PH NO B.D.D. B.S. CYCLE TIMER 1 HR ON 2 HRS OFF EF -20 GREENHECK SW -18-30 KITCHEN HOOD 4,200 3.4 3 1727 460V/3PH CWBH, WEATHER HOOD, INTER TO RUN W/MUA-3 EF -21 GREENHECK SP -25 SECURITY HOLD 141 HP -1 TRANE 1 BWC 120C4 3RD FLOOR UPPER WEST LEVEL 10 4,000 1.00 EF -22 & 25 2 825 (3) - 1' - - 300 460V13PH/60 72 1,108# 29 88KW BAY96x243A W/ OVERSIZED MOTOR, HORIZONTAL DISCHARGE, BAY 28x138 T'STAT HP -2 TRANE / BWC 12004 3RD FLOOR UPPER EAST LEVEL 10 4,000 1,00 - 2 825 (3) 0.25 ` 1,550 - 300 460V/3PH/60 72 1,108# 29 88KW BAY96x243A W1 OVERSIZED MOTOR, HORIZONTAL DISCHARGE, BAY 28x138 TSTAT HP -3 TRANE / BWC 090F4 RESTAURANT/KITCHEN 71/2 3,000 1.25 - 1 1/2 835 (2) 1/2 TF -1=1725 TF -2=1381 120V/1PH TE HANGERS; VIB ISO!. HONEYWELL T70758 REMOTE EMP: CONTROLLER 450 460V/3PH/60 35 1,500# 9 96KW BAY96x249A W/ ECONOMIZER, ROOF CURB, OVERSIZED MOTOR, BAY 28x138 T'STAT HP -4 TRANE 1 BWC 090F4 RESTAURANT/KITCHEN 71/2 3,000 1.25 745 1 112 835 (2) _ N/A - - 450 460V/3PH/60 50 1,500# 19 92KW BAY96x250A W/ ECONOMIZER, ROOF CURB, OVERSIZED MOTOR, BAY 28x138 T'STAT HP -5 TRANS I BWC 060G4 EMPLOYEE LOUNGE 5 2,000 0.50. 10,8 31r 4 MED 18" x 12" \ , EDC 3-3 _ 300 460V/3PH/60 30 800# 9.96 KW W/ ECONOMIZER ROOF CURB, TIME DELAY, O.D.T.; O,D,T, BOX, BAY 28x38 T'STAT SERVED BY FIT 3-6 EDC 3-4 REDD-11 MODEL R 3 277V/10 10,8 1 1600 16" x 16" SERVED BY FIT 3-7 EDC 3-5 REDD-1 / MODEL R 3 277V/10 10.8 1 1170 18" x 121" SERVED BY FIT 3-8 F.C.1&2 TRANE / BTE 1208-400GA ALTERATIONS & TAILOR 10 4,000 0.75 - 11/2 700 (5) - - - - 460V/3PH160 15 (EA) 500# 7.14 KW W/ ELECT. HEATER FILTER ENCLOSURE & 25TG C125TG H T'STAT W/ AUTO C.O. C,�1.1&2 TRANS/BTA 120 D*400A ALTERATIONS & TAILOR 10 3 2080 22" x 14" SERVED BY HP -2 EDC 4-2 REDD-1 / MODEL R 3 277V/10 10,8 1 460V/3PH/60 29 (EA)800# SERVED BY HP -2 WI LOW AMB HD. PRESS C O0 N 1 RO DAMPER T.D. RELAY ANTI H TCY LE L M S OR C CONTROL& SPRINK ISO FC -3 TRANE / TWHO60P150A GIFTS 4 2,000 - - 3/4 277V/1PH _ - 2081230/1 PH DRESSING 250 885 850 CU -3 TRANE / TTA072A400A GIFTS 4 - PSF FAN INDUCTION TERM. - - - N/A 208/230/1 PH 277V/1PH - W/HEAD PRESS, CONTROL# BAYLOAMIOIA, BRAZE ADAPTERS# 8581 -01 -0301 -EQ FIT 2-20 PSF FAN INDUCTION TERM. OFFICE 253 800 , N/A 277V/1PH FAN SCHEDULE MARK MFR.IMODEL AREA SERVED CFM ESP HP RPM POWER REMARKS EF -1" GREENHECK G-100-8 ROOMS 120,121 550 0.375 1/12 1,140 120V/1PH 8:S., B.D.D. EF -2 GREENHECK GB -24-15 TAILOR HOOD 4,430 • 0,55 1 1/2 859 460V/3PH B.S., B.D.D. INTERLOCK TO RUN W/MUA-1 EF -3 GREENHECK GB 1810 ALTERATION HOOD 2661 075: 1 1,078 460V/3PH MODEL# SP -27-250 CFM/25 S.P. EF -43 GREENHECK SP -60 ROOM 223 (BOILER ROOM) 650 0.8 1/6 1,050 120V/1P H H T'STAT ONEYWELL CLG #7651A2028 EF -5' GREENHECKG-100-A ROOMS 241, 243, 244 1;105 0,375 1/4 1,725 120V/1PH 8.5., B.D.D. EF -6' GREENHECK CUE-10-BX-QD ROOMS 342, 343 525 0.25 1/8 1,140 120V11PH B.S., B.D,D. EF 7 ' GREENHECK GB -14-3X D Q ROOMS 322, 326; 327. 328,329 & VENDING 1755 0.25 1/3 1 194 120V/1PH, B, S. B.D.D. EF -81 GREENHECK GB-14-4X-QD ROOMS 307, 309, 317 700 0,25 1/4 940 120V11PH B.S., B.D.D. EF -9 GREENHECK BSQ-14-5 DISPLAY WORKROOM 404 1,825 0.38 1/2 1,331 120V/1PH HANGERS, VIB. ISOL. BELT GUARD ON/OFF WALL SWITCH EF -10 GREENHECK GW-95-DGEX-00 ELECTRICAL ROOM 411 460 0.25 112 1,331 120V/1 PH 8,S,,B,D.D. & HONEYWELL T651A2028 TSTAT EF -11 GREENHECK GW -95-G FREIGHT ELEV. MACH. ROOM 410 505 0.25 1/12 1,300 120V/1 PH B.S.,B,D.D. & HONEYWELL T651A2028 TSTAT EF -12 GREENHECK GW -95-G PASSENGER ELEV. MACHINE ROOM 410 560 0.25 1/12 1,330 120V/1 PH B.S.,B.D.D. & HONEYWELL T651A2028 T'STAT EF -13 GREENHECK SP -27 DISPLAY WINDOW 112 330 0.25 1/15 (2.1A) 1,550 460V13PH HONEYWELL TSTAT T651A2028, BY-PASS TIMER (60MIN) RHODES 90008 EF -14 GREENHECK SP -27 DISPLAY WINDOW 116 360 0.25 1/15 (2.1A) 1,550 460V/3PH HONEYWELL TSTAT T651A2028, BY-PASS TIMER (60MIN) RHODES 90008 EF -15 GREENHECK SP -27 DISPLAY WINDOW 129 310 0.25 1115 (2.1A) 1,550 460V13PH HONEYWELL T'STAT T651A2028, BY-PASS TIMER (60MIN) RHODES 90008 EF -16 GREENHECK SP -27 DISPLAY WINDOW 133 326 0.25 1/15 (2.1A) 1,550 460V/3PH HONEYWELL TSTAT T651A2028, BY-PASS TIMER (60MIN) RHODES 90008 EF -17 GREENHECK SP -27 DISPLAY WINDOW 151 300 0.25 1/15 (2.1A) 1,550 460V/3PH HONEYWELL TSTAT T651A2028, BY-PASS TIMER (60MIN) RHODES 90008 EF -18 GREENHECK SP -27 DISPLAY WINDOW 102 300 0.25 1/15 (2.1A) 1550 460W3PH HONEYWELL TSTAT T651A2028, BY-PASS TIMER (60MIN) RHODES 90008 EF -19 GREENHECK CUE -10-A METHANE GAS VENT 940 0.50 1/4 1,725 120V11PH NO B.D.D. B.S. CYCLE TIMER 1 HR ON 2 HRS OFF EF -20 GREENHECK SW -18-30 KITCHEN HOOD 4,200 3.4 3 1727 460V/3PH CWBH, WEATHER HOOD, INTER TO RUN W/MUA-3 EF -21 GREENHECK SP -25 SECURITY HOLD 141 165 0.125 1/40 (1.A) 1,050 460V/3PH ON WITH LIGHTS EF -22 & 25 GREENHECK SP -50 CONFERENCE 210, 306 EF -22=450 EF -25=530 0.125 1/15 (2.5A) 1,050 460V/3PH W/ SOLID STATE SPD CONTROL EF -23 GREENHECK SP -27 HOSIERY STOCK 111 280 0.25 1/15 (2.1A) 1,550 4600/3PH WI SOLID STATE SPD CONTROL EF -26 GREENHECK SP -27 DISPLAY WINDOW 153 300 0.25 1/15 (2.1a) 1,550 460V13PH HONEYWELL TSTAT T651A2028, BY-PASS TIMER (60MIN) RHODES 90008 EDC 2-15 REDD-1 I MODEL R 1.5 277V/10 5.4 1 795 14" x 12" SERVED BY FIT 2-17 .2* GREENHECK But= -107 & WEST ENTRIES NORTH0,375 TF -1=1030 , F-2=1065 ' 5.4 1/2 TF -1=1725 TF -2=1381 120V/1PH TE HANGERS; VIB ISO!. HONEYWELL T70758 REMOTE EMP: CONTROLLER EDC 2-17 REDD-1 1 MODEL R 1.5 277V/10 5.4 1 290 10" x 6" SERVED BY FIT 2-19 (RM 249) EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING NEW NEW EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING MISCELLANEOUS EQUIPMENT SCHEDULE MARK ITEM AREA SERVED DESCRIPTION VAV-1 TERMINAL UNIT DISPLAY 112 1340 CFM, MFR. BY PSF VAV-2 TERMINAL UNIT DISPLAY 116 1340 CFM MFR. BY PSF VAV-3 TERMINAL UNIT MONEY ROOM 304 330 CFM, MFR BY PSF VAV-4 TERMINAL UNIT CONF. RM 210 240 CFM, MFR. BY PSF VAV-5 TERMINAL UNIT SECURITY 204, 205, 206 225 CFM, MFR BY PSF G ANEMOSTAT / 3PTD TITUS 1 PDR 24X24 LAY -IN R.A, ! EXH. EF -24 DAYTON 130506 BRASS PLUMB VIDEO DISPLAY RM 335 1470 CFM/.375SP/ 3/4HP11725 RPM1115V/10 EF -27 GREENHECK 1 SP -27 SECURITY RM 205 MODEL# SP -27-250 CFM/25 S.P. EF -28 GREENHECK / SP -60 MA T. SUPPLIES RM 407 MODEL# SP -60-940 CFM/.75S.P. ANEMOSTAT 1 S2V _ e.URFACE EXPOSED FASTENERS S.A.SA MOUNT DOUBLE DEFLECTION SUPPLY GRILLE HUM -1 WALTON 1S' i--2 P.O.S./TELE RM 352 2 LBS/HR fp 115V/1 PH, W/WALTON P-185 WALL MOUNTED HUMIDISTAT SURFACEMOUNT MO NT DOUBLE DEFLECTION SUPPLY T REGISTER N ANEMOSTATIS3HD TITUS / 23RL SHOEMAKER' 915 (HORIZ.) 916 (VERT.) EXPOSED FASTENERS MUA-1 GREENHECK 1 BCF208-15 TAILOR SHOP 2700 CFM @ 0.75" U., 1154 RPM, 1 1/2 HP, 460V130160HZ MUA 2 GREENHECK /CSP 55 BOILER RM 223 COMBUSTION AIR FAN, 900 CFM © 0.15" S.P., 1100 RPM, 1/3 HP, 120V/10160, INTERLOCK TO RUN W/BOILER & EF -4 MUA-3 GREENHECK / BCF207 KITCHEN HOOD 1360 CFM C 0.5 S.P.,1403 RPM, 314 HP, 4601/130/60HZ S RELIABLE ! 025 EXPOSED FASTENERS SA GV -1 GREENHECK 1 GRS-20 PASS. ELEV SHAFT RELIEF VENTILATOR DIFFUSER SCHEDULE MARK MFRIMODEL NOTES DESCRIPTION A ANEti10STAT! PRS TITUS 1 PMC SHOEMAKER 1500 MA EXPOSED FASTENERS S.A, 4 WAY SURFACE MOUNT PERFORATED FACE DIFFUSER I BLACK INSIDE 35 ANEMOSTAT/ PRT TITUS! PMC -DF 24X24 LAY -IN S.A. PERFORATED TEGULAR Y -IN FACE DIFFUSER E ANEMOSTAT I3P TITUS ' 8R SHOEMAKER / 600 P EXPOSED FASTENERS R.A. I EXH, 4 WAY SURFACE MOUNT PERFORATED FACE DIFFUSER !BLACK INSIDE F ANEMOSTAT / 3PT EXPOSED FASTENERS R.A. I EXH. PERFORATED TEGULAR LAY IN RETURN WITHOUT DUCT COLLAR G ANEMOSTAT / 3PTD TITUS 1 PDR 24X24 LAY -IN R.A, ! EXH. PERFORATED TEGULAR LAY -IN RETURN OR EXHAUST GRILLE WITH DUCT COLLAR H ANEMOSTAT / PRE 24X24 LAY -IN S.A. PERFORATED LAY -IN DIFFUSER J ANEMOSTAT/3PRD TITUS I PAR SHOEMAKER 1600 PT 24X24 OR 24X12 LAY -IN R.A. /EXH, PERFORATED LAY -IN WI DUCT COLLAR L ANEMOSTAT 1 S2V _ e.URFACE EXPOSED FASTENERS S.A.SA MOUNT DOUBLE DEFLECTION SUPPLY GRILLE M ANEMOSTAT IS2V0 TITUS 1300RS E SHOEMAKER EXPOSED FASTENERS S.A. SURFACEMOUNT MO NT DOUBLE DEFLECTION SUPPLY T REGISTER N ANEMOSTATIS3HD TITUS / 23RL SHOEMAKER' 915 (HORIZ.) 916 (VERT.) EXPOSED FASTENERS R.A.1 EXH. SURFACE MOUNT RETURN OR EXHAUST GRILLE Q ANEMOSTAT/ GC -5 EXPOSED FASTENERS R.A. / EXH, SURFACE MOUNT EGGCRATE GRILLE R ANEMOSTAT i RMD-S TITUS 150F SHOEMAKER/600 EXPOSED FASTENERS S.A, SURFACE MOUNTED DIFFUSER S RELIABLE ! 025 EXPOSED FASTENERS SA MOUNTED DIFFUSER WITH TWO WAY ADJUSTABLE BLADES SP SPECIAL GIRD THROW AWAY F.C. 2 REFER TO FLOOR PLAN FOR DESCRIPTION AND SIZE T ANEMOSTAT IS3HOD EXPOSED FASTENERS R.A. I EXH. SURFACE MOUNT RETURN OR EXHAUST REGISTER (STEEL) V SHOEMAKER 1700 DVD 24X24 LAY -IN S.A. 4 - WAY REMOVABLE CORE DIFFUSER AND CONCEALED FASTENERS W SHOEMAKER / DVD EXPOSED FASTENERS S.A. SURFACE MOUNT 4 -WAY DIFFUSER *Or Equivalent TITUS. EXISTING EXISTING REBALANCE EXISTING REBALANCE EXISTING REBALANCE REBALANCE EXISTING REBALANCE EXISTING EXISTING REBALANCE EXISTING NEW EXISTING EXISTING REBALANCE EXISTING EXISTING REBALANCE EXISTING REBALANCE EXISTING REBALANCE EXISTING EXISTING REBALANCE REBALANCE REBALANCE EXISTING REBALANCE EXISTING REBALANCE REBALANCE EXISTING. EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING EXISTING ING NEW FILTER SCHEDULE MARK QTY SIZE TYPE AC -1 35 16' x 20" x 2" AMERICAN AIR FILTER - PERFECT PLEAT AC -2 35 16" x 20" x 2" AMERICAN AIR FILTER - PERFECT PLEAT AC -3 35 16" x 20" x 2" AMERICAN AIR FILTER - PERFECT PLEAT AC -4 35 16" x 20" x 2" AMERICAN AIR FILTER - PERFECT PLEAT AC -5 20 20" x 25" x 2" AMERICAN AIR FILTER - PERFECT PLEAT AC -,6 20 20" x 25" x 2" AMERICAN AIR FILTER - PERFECT PLEAT ACO 4 16" x 25" x 2" AMERICAN AIR FILTER - PERFECT PLEAT AC -8 480 10" x 10" SERVED BY FIT 1-3 HP -1 4 20" x 25" x 2" AMERICAN AIR FILTER - PERFECT PLEAT HP -2 4 20" x 25"2" AMERICAN AIR FILTER - PERFECT PLEAT HP -3 4 20" x 201E x 2" AMERICAN AIR FILTER -.PERFECT PLEAT HP -4 4 20" x 20" x 2" AMERICAN AIR FILTER - PERFECT PLEAT HP -5 2 16" x 25" x 2" AMERICAN AIR FILTER - PERFECT PLEAT T/HOOD VERIFY VERIFY THROW AWAY NH OD VERIFY VERIFY THROW AWAY K/HOOD VERIFY VERIFY GREASE F.C.1 --T 8 14" x 20" x 2" THROW AWAY F.C. 2 8 14" x 20" x 2" THROW AVIAY 16.3 2 1000 8 x 12 FIT BOX SIZES (VSEF SERIES) 1205SQ 1 EA 16" x 20" x 1" AMERICAN AIR FILTER ELECTRIC DUCT HEATER SCHEDULE MARK MFR./MODEL KW POWER. FLA NO. STG CFM - T DUCT SIZE REMARKS EDC 1-1 REDD 1 /MODEL R 1 277V/10 3.6 1 150 8" x 8" SERVED BY AC -1 EDC 1-2 REDD-1 / MODEL R 2 277V110 7.2 1 955 14' x 12" SERVED BY FIT 1-2 EDC 1-3 REDD 1 /MODELR 2 277V/10 7.2 1 480 10" x 10" SERVED BY FIT 1-3 EDC" 1-4 NOT USED 277V/1 PH - PSF FAN INDUCTION TERM. � EDC .5 / REDD-1 MODEL R 3 277V/10 10,8 1 925 14" x 12" SERVED BY FIT 1-5 EDC 1-6 REDD-1 / MODEL R 2 277V/10 7.2 1 505 12" x 10" SERVED BY FIT 1-6 EDC 1-7 REDD / MODEL R 3 277V/10 10.8 1 1500 16" x 16 SERVED BY FIT 1-7 EDC 1-8 REDD-11 MODEL R 7.5 460V/30/60 16.3 2 1000 8 x 12 SERVED BY TF -1 k EDC -9 � R L460V/30/60 ED D-1 / MODER 7 .5 OFFICE 134 16,3 2 I000 18 x 12 SERVED BY TF -2 277V/1PH FIT 1-7 PSF FAN INDUCTION TERM. DRESS 136 AND DRESS 138 1420 EDC 2-1 REDD 1 / MODEL R 1,5 277V/10 5.4 1 610 12" x 10" SERVED BY FIT 2-2 (RM 254) EDC 2-2 REDD-11 MODEL R 1.5 a 2770110 5.4 1 620 12" x 10"(RM) BY FIT2- 2 2 SERVED 30 - C 3 ED � - REDD 1/ M DEL R 0 , 277V1, 0 3;�r 1 12u 8 x 6"SERVED BY FIT 2-4 EJC 2-4 REDD-1 / MODEL R 2.5 277V/10 10 9 1450 18" x 12 SERVED BY FIT 2-5 EDC 2-5 REDD-11 MODEL R 2 277V/10 7.2 1 890 14" x 12" SERVED BY FIT 2-6 EDC 2-6 REDD-1 / MODEL R 0 3 277V/10 10.8 1 950 14" x 12" SERVED BY FIT 2-7 EDC 2-7 REDD-1 1 MODEL R 1.5 277V/10 5.4 1 700 12" x 10" SERVED BY FIT 2-8 EDC 2-8 NOT USED 240 900 N/A - 277V/1PH EDC 2-9 REDD-1 / MODEL R 1.5 277V/10 5,4 1 745 12" x 10" SERVED BY FIT 2-10 EDC 2-10 REDD-11 MODEL R 3 277V/10 10.8 1 1480 18" x 12" SERVED BY FIT 2-11 EDC 2-11 REDD-1 / MODEL R 3.5 277V/10 12.6 1 1450 18" x 12" SERVED BY FIT 2-12 EDC 2-12 REDD-11 MODEL R 1 277V/10 3,5 1 750 14" x 121" SERVED BY FIT 2-13 EDC 2-13 REDD-1 / MODEL R 3 277V/10 10.8 1 1740 ' 16" x 16" SERVED BY FIT 2.14 EDC 2-14 REDD-1/ MODEL R 1,5 277V/10 5.4 1 935 14" x 12" SERVED BY FIT 2-16 EDC 2-15 REDD-1 I MODEL R 1.5 277V/10 5.4 1 795 14" x 12" SERVED BY FIT 2-17 EDC 2-16 REDD-11 MODEL R 1.5 277V/10 5.4 1 250 10" x 6" SERVED BY FIT 2-19 (RM 251) EDC 2-17 REDD-1 1 MODEL R 1.5 277V/10 5.4 1 290 10" x 6" SERVED BY FIT 2-19 (RM 249) FIT 2-10 PSF FAN INDUCTION TERM, AIRLINE FITTING 226 745 . N/A EDC 3-1 REDD-1 1 MODEL R 3 277V/10 10.8 1 970 14" x 12" SERVED BY FIT 3-4 EDC 3-2 REDD-1 / MODEL R 3 277V/10 10,8 1 1190 18" x 12" SERVED BY FIT 3-5 (RM 334) EDC 3-3 REDD-1 / MODEL R 2 277V/10 7.2 1 880 14" x 12" SERVED BY FIT 3-6 EDC 3-4 REDD-11 MODEL R 3 277V/10 10,8 1 1600 16" x 16" SERVED BY FIT 3-7 EDC 3-5 REDD-1 / MODEL R 3 277V/10 10.8 1 1170 18" x 121" SERVED BY FIT 3-8 EDC 3-6 REDD-1 / MODEL R 4 277V/10 14.4 1 1880 16" x 16" SERVED BY FIT 3-9 FIT 2-15 PSF FAN INDUCTION TERM. WOMEN'S LOUNGE 243 AND WOMEN'S ROOM 244 1000 EDC 4-1 REDD-1 1 MODEL R 20 460V/30/60 43.5 3 2080 22" x 14" SERVED BY HP -2 EDC 4-2 REDD-1 / MODEL R 3 277V/10 10,8 1 585 12" x 10" SERVED BY HP -2 FAN INDUCTION TERMINAL UNIT SCHEDULE MARK MFR./ MODEL AREA SERVED FAN CFM PRIMARY AIR FAN ELECTRIC HEAT REMARKS MIN MAX HP SPEED POWER KW STAGE POWER M-141 FIT 1-1 M-151 ROOF HVAC PLAN - REFERENCE ONLY M-201 HVAC DETAILS FIT 1-2 PSF FAN INDUCTION TERM. HOSIERY STOCK 111 955 N/A - 277V/1 PH FIT 1-3 PSF FAN INDUCTION TERM. OFFICE 119, MENS 121 480 100 400 N/A - 277V/1PH FIT 1-4 FIT 1-5 PSF FAN INDUCTION TERM. DRESS 126 AND BULLPEN 127. 1030 200 800 N/A - 277V/1PH FIT 1-6 PSF FAN INDUCTION TERM. OFFICE 134 800 N/A - 277V/1PH FIT 1-7 PSF FAN INDUCTION TERM. DRESS 136 AND DRESS 138 1420 240 900 - - FIT 2-1 PSF FAN INDUCTION TERM. DRESS 201 925 150 650 N/A - 277V/1PH FIT 2-2 PSF FAN INDUCTION TERM. STOCK 254 & STOCK 202 1230 NIA - 277V/1PH FIT 2-3 PSF FAN INDUCTION TERM. DRESS 203 1610 240 900 N/A - 277V/1PH FIT 2-4 PSF FAN INDUCTION TERM. FIT 2-5 PSF FAN INDUCTION TERM. OFFICE 211 1450 N/A 277V/1PH FIT 16 PSF FAN INDUCTION TERM. DRESS 215 AND HOLD 216 890 125 500 ; NIA - 277V/1PH FIT 2-7 PSF FAN INDUCTION TERM. PERSONAL SHOPPER 218 950 NIA - 277V/1PH FIT 2-8 TRANS VSEFI205SQ DRESS 219 1520 275 1100,E 1/2 VAR 277V/1PH 4 1 277V/1PH 1 FIT 2-9 PSF FAN INDUCTION TERM. 1. FIT 2-10 PSF FAN INDUCTION TERM, AIRLINE FITTING 226 745 . N/A 277V/1 PH FIT 2-11 PSF FAN INDUCTION TERM. DRESS 229 1480 240 900 N/A 277V/1PH FIT 2-12 PSF FAN INDUCTION TERM. GIFT 230. 1450 4� I N/A 277V/1PH FIT 213 PSF FAN INDUCTION TERM. P.O,M; OFFICE 232 AND STOCK 231 800. N/A -- 277V1 PH / - FIT 214 PSF FAN INDUCTION TERM. DRESS 236 AND STOCK 235 1740 250 1000( N/A - 277V/1PH FIT 2-15 PSF FAN INDUCTION TERM. WOMEN'S LOUNGE 243 AND WOMEN'S ROOM 244 1000 N/A 277V/1 PH FIT 116 PSF FAN INDUCTION TERM. TBD DR 935. 180 750 N/A 277V/1PH FIT 2-17 PSF FAN INDUCTION TERM. OFFICE 248 795 N/A 277V/1PH FIT 118 PSF FAN INDUCTION TERM. DRESSING 250 885 200 850 NIA - 277V/1PH FIT 2-19 PSF FAN INDUCTION TERM. STOCK 249 AND STOCK 251 800 N/A 277V/1PH FIT 2-20 PSF FAN INDUCTION TERM. OFFICE 253 800 , N/A 277V/1PH FIT 3-1 PSF FAN INDUCTION TERM. DRESSING 334 685 125 500 N/A 277V/1PH - FIT 3 2 PSF FAN INDUCTION TERM. 2 LADIES LOUNGE 327 & MOTHERS RM 329277V11 WOMEN. RM 322, LADIES RM 3 8,1350 150 600 N/A 2 PH FIT 3-3 PSF FAN INDUCTION TERM. DRESSING 344 460 100 380 NIA - 277V/1PH FIT 3-4 PSF FAN INDUCTION TERM. OFFICE 332 AND STOCK 331 970 N/A - 277V11PH FIT 3-5 PSF FAN INDUCTION TERM. BP 351 1825 375 1500 N/A 277W1PH FIT 3-6 PSF FAN INDUCTION TERM. OFFICE 344, HOLD 346 & MEN'S RM 343 880 N/A 277V11 PH FIT 3-7 PSF FAN INDUCTION TERM. DRESSING 382 1490 290 1150 N/A 277V/1PH FIT 3-8 PSF FAN INDUCTION TERM. DRESSING 393 1125 220 850 N/A - 277V/1PH FIT 3-9 PSF FAN INDUCTION TERM. OFFICE 360, STOCK 362 1880 N/A - 277V/1 PH NOTES: 1, PROVIDE WITH INDEPENDENT DDC CONTROLS, UL LISTING, S&D DISCHARGE TEMPERATURE SENSOR (MAMAC TE -205) WITHOUT LOGO, SPECIAL BOTTOM ACCESS PANEL, SCR FAN SPEED CONTROL, MERCURY CONTACTORS FOR FIT BOXES WITH ELECTRICAL HEAT, SERIES CONSTANT FAN. Ib REVISIONS IAS, changes shall be made to the scope eft -ori: without prior approval of AtyiIa Building Division. ft =„sons will require a new plan submittal include additional plan review fees. FILE COPY Paan/# N®. t41!!OI( (1, P ^. W � � �b =rpm! of =elution on c m s does not autt . 33 of any adopted cob or ordnance. RS :pt twrOVA Reit Copy and`' ' ' - '' LS admadedga By ovii Date -a Ol 3 City Of Womb BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JAN 18 ?nit uL City of Tukwila BUILDING DIVISION DRAWING SCHEDULE DWG. DESCRIPTION M-001 HVAC SCHEDULES AND GENERAL NOTES M-111 FIRST FLOOR HVAC PLAN - DEMOLITION M-112 FIRST FLOOR HVAC PLAN M-121 SECOND FLOOR HVAC PLAN - DEMOLITION M-122 SECOND FLOOR HVAC PLAN M-131 THIRD FLOOR HVAC PLAN - DEMOLITION M-132 THIRD FLOOR HVAC PLAN M-141 UPPER LEVEL HVAC PLAN - REFERENCE ONLY M-151 ROOF HVAC PLAN - REFERENCE ONLY M-201 HVAC DETAILS 201 O O 0 206 303 4300 www.nordstrom.com z s o a co 0 � z 0 O 762 8381 0 O N E 0 U 0 c0 0 N E 4- cn a Q' CALLISON E O e O O 0 0 0 Z LD 0 0 SOUTHCENTER J 200 W o0 ZQ v _ co 0 0 0 0 re - PROJECT NUMBER 212283.00 ISSUED ISSUED /REVISED DATE GEN BID PERMIT 11/12/12 RECEIVED CITY OF TUKWILA JAN 1 4 2013 PERMIT CENTER HVAC SCHEDULES AND GENERAL NOTES M-00 1 is J K O O O a) ,.r vE Z O a O 0 2 cmOT E 0 > '• d' co coO C. Q co MN F r O O 'a (I)N co co o �0 ~ +-COO c W Q; O 4-' O O ti al a) CV CV o —u)I— u. 12x12 47(11' H 24.7_1U RD LIFtR 12x 12 4701 Briar Noir 6,[5rin TIL 6315x14 Atialaillaill111111111MM...22.11E1111111 oo co co a la cNi CD 1414 fkl 1414 60511. 1311 635 II IMMO Amd 14141 • -J 0 G AFF 0— 0 0 (/) .. 18"x12" LO ce csi co .12 co w co co ca 0 z REVIEWED FOR CODE COMPLIANCE APPROVED ISSUED / REVISED DATE GEN BID PERMIT 11/12/12 JAN 1 8 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 1 4 2013 PERMIT CENTER LEGEND — — DEMO EXISTING TO REMAIN FIRST FLOOR HVAC PLAN - DEMOLITION M 1 1 1 1D22 1 I 1I 111 • -J 0 G AFF 0— 0 0 (/) .. 18"x12" LO ce csi co .12 co w co co ca 0 z REVIEWED FOR CODE COMPLIANCE APPROVED ISSUED / REVISED DATE GEN BID PERMIT 11/12/12 JAN 1 8 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 1 4 2013 PERMIT CENTER LEGEND — — DEMO EXISTING TO REMAIN FIRST FLOOR HVAC PLAN - DEMOLITION M 1 1 1 J U U I IL IJ I `1 I I i 1 I 12"5' IMINIMINIED I 8X8 ' � � 451 H I 1 L1 I ! .' `1145 H ' ' 188'X26" �!!! d-1 8x8 �� _ 1 , FIT 2-5 {— 8x8 i Mt:' �►► 1 $. 145 H 145 H I I^, 1 ;; r I I 8x8 1 5----4--* ,' : 3 '16 h � : 18nx i .f s 1` \ { q � r 2 E -FIT1-2- l r- EDC 4 ../ -et l - NOVI 1 8x8 _1.1451„H --8 8-- 162" 6 6 Z 0 I- H W z0 O Z CO O N www.nordstrom.com 10x10 3301 B 20"x8" 3501 B FIT 2-9 ttt nmi_mi=ammarT � MOP =r , 3'� r„m,, ,r 1414 V z J 4 V 2 z 4 I- ¢,W -J ( • U. z 00 d Avenue South 9322 14th N O. 0 C) co O r M co < C)) CD ▪ CD N (NI a) CO IF ilm CO Cr) CO CV CO N- CD O N CO 0 co C) ci E a 12"01 • 4$1 Osti *wt. .447, 4,,t1 k /A. #4 it 1 , � ,s,tr To/ 110X4 I3GIiM !16x16 7501 i 114x 14 2201 M FIT 2-112) O N 116x161 114141 FIT ;:2:-13 114x14 €351 IB 12x12 °`i 1 u dr �, I A. r I I 1D, „ 1 i . , eu�� . lb ,_._, •'�„. i 1 ` 1j2-11 —�- ill liallMil 51.171.111:11:-. I 0 2 kk ; O I : 100 �'1:41t11NW w - %IISt esu itra�I':IMIMII(�� h_ 11 LL. ��!�I,}�;�r i MAIM l , flP1I!! --11 190 i MIMMINAmmmi W II -1-4 3 145--1-M PROJECT NUMBER 212283.00 tQW1B 3 t5 AFT EDC : -15 i -111 "1 I 17 _ 1 I 11 ti 1 `.' • t , 11 ' z ! .„,oyl 1 V?'3�y �:»+,✓i iALa f ' i 11 i 1 % ._,.. 1 _ - i-' - ` .�%.7 ,�-/ ( 4 i i 11 1135.. I ttC t 4 i ' I # I ` i - _ 1 , • 11 t �- I j i j f�q �N TO ."..-4- �. ,,�.yt - z k:.:t i FST. ! 1 E f 4 I - s: I , i 1 i tl U R 1 7 1 1• 1 I i 1 i -I i( 1 1 1 L ' a 1 I i i L1 �. -i _1_ _- _1 -1 - ! 1 i f 1 I- _ - -'-_---"` OPFN TO i - ---- . _ _ ~` GiFi_V + `— I;I f 1 I i. I 0 ii! 1 i i 1 ! iIit . f �� � 1 1 O 1 1 \.,J -.I I - L— I J L,J I 1 1 (i•` 1! I I I I I 11 1 11 1 lis I I FIT 2-112) O N 116x161 114141 FIT ;:2:-13 114x14 €351 IB 12x12 °`i 1 u dr �, I A. r I I 1D, „ 1 i . , eu�� . lb ,_._, •'�„. i 1 ` 1j2-11 —�- ill liallMil 51.171.111:11:-. I 0 2 kk ; O I : 100 �'1:41t11NW w - %IISt esu itra�I':IMIMII(�� h_ 11 LL. ��!�I,}�;�r i MAIM l , flP1I!! --11 190 i MIMMINAmmmi W II -1-4 3 145--1-M PROJECT NUMBER 212283.00 tQW1B 3 t5 AFT EDC : -15 i -111 "1 I 10&4 12"x6" DN 70"x28"UP & DN DRAWING NOTES: 0 RAI G RA G ®Fite (DI8x 10018 B 24x24 24x12 ISSUED / REVISED DATE GEN BID PERMIT 11/12/12 RECEIVED CITY OF TUKWILA JAN 1 4 2013 PERMIT CENTER LEGEND - - DEMO EXISTING TO REMAIN SECOND FLOOR HVAC PLAN - DEMOLITION CIP RI HT 012 AL I M-121 K J D 3C N N E a rn 0 cn 0 d O E co ceM O N- ' I L N U 0 -01 Z M ttOO a) N 'O O 0 0 0- C..7 U N CV a / 88"x26" UP TO 1 THIRD FLR • 88 145 H FIT 2-5I ) 88"x26" 0.4; TO BOILER HOOD 8x8 ! 45A H 10"0 GAS FLUE UP & D _.._1274—UP—&--G._ I FIT k-9 fid — 0 0 0 0 0 14x14 8" DN: 63513_ \144t#04.4.40 4.4‘. 44, 4, I vs* s4.#"+++++#40411#114#4..relo‘ . 12<12 12x112 112"41 MM. 1;30;1 M 114x14 1636; 9=' I (FIT 2- flu2)RB OD 0 —0 x 2201 M I E f ; 40- I 1 MINIliMiliii � KU'RE .ii o��a� a gam or All►st 1 14'-I5" " G 1rx14 10-:10 1751 B 16x16 1414 05�3 : `s l fF t; ER ELF [t,[il011 -L Anairr w' \\Ni. iMIMP \ \‘‘11111111111111 E!__� v _ ii i I i Nikki 10Ella— s d w4 ry i inane , ii r • [U I RB ` ip/-u , • 11 - allFAID21E1 Vt..: '1 11 40 Elsiniilro•- Ira L i Y ji--84 f 5 1 1'i�a. 1�. ;14 14"$ UP --95- 12"x6" DN 1 mom DRAWING NOTES: 0 0 0 0 0 0 B 8x8 1001 B 111 SCALL: 1/8" 1' 0" 5 ) 16 i REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 s City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 1 4 2013 PERMIT CENTER LEGEND EXISTING TO REMAIN NEW DUCTWORK O 0 O a) 0 Z _ a) 2 c O > Q II- r w z" 0 OZ� www.nordstrom.com .-. 0 z J .1 a 20 00W co z< W � v !!ww v/ H O O PROJECT NUMBER 212283.00 ISSUED / REVISED DATE GEN BID PERMIT 11/12/12 02012 CALLISON SECOND FLOOR HVAC PLAN M -122 1 } 1 I a Co t 0 1_ 0 0 01 i 0 0.� 0 0 i 3 0 r I E. N �t i \.:d. .I ; �..J o lJ ?,..d i I ; E ! i 0 I f i G -i P $.3i _ THIRD 1 ..I_....,.__:. i i 1 ( Y E I i i i i i i 1 i �N __.....-....._..---F....-..._ .. —��--' - , i I - UP F. ?. - { t '—_- -- ___Tom: i i G .._.:::w -r—__.....;,- "I - 11 , ±11 FIRST I 1 i ( /// 1 I 9 , I. ISD !, I I I I II 1 _ __--------'' OPEN TO L--N---f --"" --a-- BELOW _.`.�..-_-, 'r I i I p i : \� 0 0 0 1 0 �1 -E` o I A, a--/ 3i 1 0 1 0 0 0 11 ' 1 ; 0 0 0 0 j o -i•- it f i 1 \___.__-__.____-__ -._ -__ ----___-___ -------_--__— _ _________ -_--`-- I E f ; 40- I 1 MINIliMiliii � KU'RE .ii o��a� a gam or All►st 1 14'-I5" " G 1rx14 10-:10 1751 B 16x16 1414 05�3 : `s l fF t; ER ELF [t,[il011 -L Anairr w' \\Ni. iMIMP \ \‘‘11111111111111 E!__� v _ ii i I i Nikki 10Ella— s d w4 ry i inane , ii r • [U I RB ` ip/-u , • 11 - allFAID21E1 Vt..: '1 11 40 Elsiniilro•- Ira L i Y ji--84 f 5 1 1'i�a. 1�. ;14 14"$ UP --95- 12"x6" DN 1 mom DRAWING NOTES: 0 0 0 0 0 0 B 8x8 1001 B 111 SCALL: 1/8" 1' 0" 5 ) 16 i REVIEWED FOR CODE COMPLIANCE APPROVED JAN 1 s City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JAN 1 4 2013 PERMIT CENTER LEGEND EXISTING TO REMAIN NEW DUCTWORK O 0 O a) 0 Z _ a) 2 c O > Q II- r w z" 0 OZ� www.nordstrom.com .-. 0 z J .1 a 20 00W co z< W � v !!ww v/ H O O PROJECT NUMBER 212283.00 ISSUED / REVISED DATE GEN BID PERMIT 11/12/12 02012 CALLISON SECOND FLOOR HVAC PLAN M -122 O O O V � Z 0 00 a) O r co co O > < -- �0 1- 0 (1) Co) 01 N- 7, 7, CO CO W re 0 4-, 0 0 O 0 ai N N N. oZ www.nordstrom.com DN op , x 2 -`FROG FIT -1-2 MOUNT ABOVE SALES CLG. N � O O In 0: co O U 0000 co co M ao)c0 N O O CO co-� '~ a-'00 N CN �c13) N W 800�- Y " s8_8 24"x16"11 (HP -1) A41 A41 A41 A4 1 A41 A4 24"x12" DN. T1D STOCK 147. \ 62"x34 R.A. -t OPNG W/F.D. 62"x34 R.A. OPNG W/F.D. 110x4 1300 10 1 10"x8" 10x4 18"x14" 210x4 10x4 14 22"x8" 14"x8 10x4 !i°4 1 MI - 17"0 KITCHEN HOOD EXH. DUCT (EF -20) Z 0 Cn J J U Z 0 J C.) 54x i.:r.. OCK 54x30' 30"x16"-2" A41 A41 I 41 a 1 . 1 iD;_._-_.-._.4..I-._ 12x4 30 M I i i f 4 SHOE TOCK FIXTURE, UPPER LEVEL SCALE 1/8" =1'-0" 24"x16"I1 (HP -1) 2001 M OPEN O BELOW LV4 S 1 r . EDC -4-2 24x30 H SIDES 12x12 12x12 24x38 48"O WRAPPED W/ 2" INSULATION AND JACKET W/ .016 MIL FIN. 800 0 0'- 30"x 1 2" 1051 N 38"x66" -2' R.A. DUCT TO AC -4 STAiR 20"x10" DN 24x18 PROJE CORR 1D li .NI 30x30 BOTH SIDES (EF -28) CD N r -3 -THIRD FLOOR UPPER LEVEL SCALE 1/8" = 1'-0" DRAWING NOTES: 1 12x6 RA J ISSUED / REVISED DATE GEN BID PERMIT 11/12/12 RECEIVED CITY OF TUKWILA JAN 1 4 2013 PERMIT CENTER N CJIw LEGEND UPPER LEVEL HVAC PLAN REFERENCE ONLY G" T M-141 K D 3C N E cn cn C3 O i 8 O E N s C 0 Z UD M 0 co 0 -0 0 0 CLz CL 0 U_ P5 gn RECEIVED Y OF TUKWILA JAN 14 2013 PERMIT CENTER COPYRfGHT©2012 CALLISON 0 0 0 a) V Cn Zo CD O 0 C O O c- E CV M M O 0 > Q d' d' L- IZ 1-o o 73 CO) aic)M o ti CD CD LT! Ir oa-100 0 � CONN N N O Z -o)F-u. cnu. N-00 ZN O COCCDCO O 0. CZ 0) Im NL 3 Q' CALLISON E 0 v 0 t0 v 0 0 0 z SOUTHCENTER J J 4 2 co 00 w co I- 0 ZQ W V • co 0 0 I - PROJECT NUMBER 212283.00 ISSUED / REVISED DATE GEN BID PERMIT 11/12/12 HVAC DETAILS M-201 DIFFUSER CAN, SPRAY PAINT OR SOUNDUNE INSIDE WITH FLAT'BLACK WHERE NOTED ON PLAN. FLEXIBLE DUCT TO 3" MOUNTING COLLAR. SEAL JOINT W/ DUCT TAPE. PERFORATED BAFFLE PLATE WITH 50% FREE AREA FLEXIBLE DUCT, SEE PLAN FOR SIZE. NOT TO EXCEED 10' IN SECURE DIFFUSER CAN LENGTH. MAX OF 90' TOTAL TO DIFFUSER WITH SCREWS BEND PER LENGTH. TO BE STRETCHED TAUT. AS SHOWN. SEAL WITH DUCT TAPE. 0 NOT USED0 AIRFLOW b - 6" 5-3/4" 14" MAX _ OVERHEAD DOOR ASSEMBLY _ ' _ INDUCED AIR - a ' a • • CMU WALL OPTIONAL PRIMARY TRANE VSEF - AIR DOOR BY e • AIR VALVE CONTROLS ENCLOSURECONTRACTOR 5-1/2" MECHANICAL •' , e �, _ e 14" MAX a 10 GAUGE GALVANIZED SUPPORT TOP OF DIFFUSER FRAME ' 'I - 1' '8" CLEAR e BRACE OUTBOARD OF DOOR RAIL BY MECHANICAL CONTRACTOR. DO I 1 ELECTRIC COILLS ENAND �� FAN CONTROCLOSURE " Nk 11 •. - , ' ` d NOT ATTACH TO OVERHEAD DOOR _ SYSTEM. - Ii!O 42 MINIMUM '.CLEARANCE.. ELECTRIC HEATER 1 l 12 GAUGE CHANNEL SUPPORT MECHANICAL GALVANIZED CONTRACTOR. IRON BY v1.:mma SUSPENDED CEILING SIDE ENTRY LAY -IN DIFFUSER - - - - - - - - TYPICAL LAY -IN TYPE DIFFUSER WITH SIDE INLET CONNECTION. SEE PLAN FOR SIZE. 3-1/2" CLEAR BETWEEN TYPICAL TERMINAL AIRFLOW DISCHARGE OUTLET FAN INDUCTION UNIT CLEARANCE TYPICAL AIR DOOR INSTALLATION DOOR RAIL AND AIR DOOR DETAIL 0 DETAIL 4 DETAIL NTS NTS NTS NTS TOP OF DIFFUSER FRAME. FLEXIBLE DUCT, SIZE. NOT TO LENGTH. MAX BEND PER LENGTH. STRETCHED FLEXIBLE DUCT TO 2" MOUNTING COLLAR. SEAL JOINT W/ DUCT SEE PLAN FOR EXCEED 10' IN OF 90' TOTAL TO BE TAUT. TAPE. ® NOT USED AIRFLOW 4' I I SAFETY CLIP AS REQUIRED BY LOCAL CODE ti 1 - 0 N_ NOMINAL EQ � NECK SIZE � EQ � 3" TRANE VAV BOX. BEAD PERFORATED BAFFLE PLATE WITH 50% FREE AREA w z N � 1" DUCTWRAP PLENUM -5 w v cn o u_ I 5'-0" TYPICAL - CENTER UNE — \ " (TYPICAL) ----I I —J \- lAY-IN TYPE DIFSER, PLAN FOR QUANTIT Y AND SI:'/ SIZE SURFACE MOUNT DIFFUSER SEE PLAN FOR QUANTITY =rm., AND SIZE VAV TERMINAL PLENUM 11" - DIFFUSER CAN O INCREASE TO 6" WITH VOLUME DAMPER IN THROAT FOR SURFACE MOUNT DIFFUSER IN HARD (NON -ACCESSIBLE) CEIUNGS. O INCREASE AS REQUIRED FOR FIRE DAMPER INSTALLATION - - - SUSPENDED TYPICAL LAY -IN TYPE DIFFUSER3" CEILING WITH TOP INLET CONNECTION. SEE PLAN FOR SIZE. TOP ENTRY LAY -IN DIFFUSER 6 DETAIL ® DETAIL 8 DETAIL _ NTS NTS NTS NTS DECKINGTOP 2 AT " TEK SCREWS#10x3/4WITH OUT CONCRETE /1/ CADDY CUP AT OF JOIST - ERICO CONCRETE SLAB 3/8"x2-3/4" WEDGE ANCHOR BOLT 1/4"x1/4" NAIL -IN ��1 MSS24 OR EQUAL, 200 #10x3/4 TEK SCREWS LB. MAX LOAD lir 1"x22GA STRAP " 10 -0 SPACING #10x3/4" TEK SCREW g BAR JOIST CONCRETE ANCHOR \______/ .?,, STRAP 3/8' FLAT WASHER 3/8" NUTTIGHTENED BOLT " 1 WIDE IN CONCRETE f HANGER STRAP 3/8" ALL THREAD (MAX. LOAD = 600 LBS) INSTALLATION STRAP INSTALLATION HANGER STRAP (MAXIMUM LOAD = 40 LBS.) _ ` ,..__.__________ �_ ._ ..... _..._ ,_ _ ..... _ .. ...... .. ...... _ _ METAL ROOF DECK BUILT-UP ROOFING / _ .___ _,.__...._... _.. µ . --1 A B EMI C r ------------ UP TO 18"0 HANGER STRAP I BAR JOIST DUCT SUPPORT (P? Q DETAIL 9 DETAIL0 ( QHANGER DETAIL •HANGER DETAIL NTS NTS I NTS NTS METAL FLOOR DECK / CONCRETE AC UM- METAL WASHER WITH NAILING STRIP (GC) STAND-OFF CUP FOR ATTACHMENT OF RECEIVER 3/8" HANGER ROD (MAX DUCT PERIMETER = 240"), OR PER TABLE 5-1, ANSI/SMACNA DUCT CONSTRUCTION STANDARDS 3RD ED. -- 1" WIDE 22 GAUGE STRAP (MAX PERIMETER = 60"), OR PER TABLE 5-1, ANSI/SMACNA DUCT CONSTRUCTION STANDARDS 3RD ED DUCT I #12 GA. WIRE DIAGONAL BRACE, CORNERS 0 TO STRUCTURE. (4 TYF'.) 3/8 ALL THREAD-` 45 - NOTE. ALL ATTACHMENTS FLUTE OF THE A. 20GA. X 1" TEK SCREWS B. 20GA. X 1" CONCRETE. C. SUPERSTRUT DECK BEFORE 75LBS D. SAME AS TYPE E. 22GA X 1" MAX LOAD F. SAME AS TYPE G. Y4"> 3/a" OR TO LOWER H. SAME AS TYPE HANGER = Y2" ATTACHMENT. ATTACHMENTS B TO DECK. HANGER (SEE DETAIL). HANGER STRAP. MAX LOAD C475 3/a" ROOFING "B" ATTACHMENT HANGER STRAP 75LBS "E" ATTACHMENT. CONCRETE "G". D ROOF DECKING STRAP. ATTACH MAX ATTACH = 75LBS DECK INSERT OR CONCRETE ATTACHED EXPANSION MAX LOAD TO METAL E MUST TO LOAD FROM OR WITH (CONCRETE WITH MAX LOAD ANCHOR Y4" DECK F NOT PROTRUDE DECK FROM UNDERNEATH = 40LBS TOP OF DECK APPROVED EQUAL) 2- #10 X 3/4" ONLY). MAX Y4" X 1Y4" EXPANSION - 50LBS COUPLED TO = 300LBS, /a" = ' LOAD G HIGHER BEFORE ATTACHED TEK SCREWS. = NAIL SAME 600LBS, f ROOFING 75LBSCANT SIZE Y2" H THAN THE TOP WITH 3- #10 X 3/4 OR TO TOP OF MAX LOAD = INTO CONCRETE. ALLTHREAD ROD = 1200LBS. A. ".• �� 3/8" BEAM CLAMP ' 3/8"x2 3/4" WEDGE ANCHOR BOLT " 3/8 NUT W/ WASHER 3/8" COUPUNG NEOPRENE GASKET7 SQUARE RECTANGLULAR DUCT SQUARE RECTANGLULAR DUCT TO STRUCTURE (4 EYP. ) � FLASHING BY I ROOFING CONTRACTOR FLEXIBLE FLASHING OVER INSULATION AND CUP FLASHING BY ROOF CONTRACTOR CANT (GC) — / /\ ':••=