Loading...
HomeMy WebLinkAboutPermit M13-0199 - CODIGA RESIDENCE - ALTERATIONCODIGA RESIDENCE 12523 50 PL S M13-0199 110 City of Tukwila Department of Community Development �,\ r 0 6300 Southcenter Boulevard, Suite #100 2 Tukwila, Washington 98188 1908 Phone: 206-431-3670 • Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 0179002885 Permit Number: M13-0199 Address: 12523 50TH PL S Issue Date: 11/15/2013 Permit Expires On: 5/14/2014 Project Name: CODIGA RESIDENCE Owner: Name: CODIGA JAMES A JR Address: 12523 50TH PL S , SEATTLE, WA, 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE, WA, 98108 Phone: (206) 296-7437 Contractor: Name: S K M CONSTRUCTION INC Phone: (425) 235-5569 Address: 14415 SE 143 PL , RENTON, WA, 98059 License No: SKMCOI*052L3 Expiration Date: 12/30/2013 Lender: Name: Address: DESCRIPTION OF WORK: INSTALLATION OF (2) BLENDING UNITS Valuation of Work: $4,644.00 Type of Work: NEW Fuel type: GAS Fees Collected: $249.00 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: bp:A Date: { V—tc 5 • • I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: DeN Ce Date: t L 6 I S--) This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 2: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 3: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 4: ***MECHANICAL PERMIT CONDITIONS*** 5: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 6: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the Tukwila Building Division. 9: All permits, inspection records and applicable plans shall be maintained at the job and available to the plumbing inspector. 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. nnl27— 6 1 Date Application Accepted: Date Application Expires: oq 19J (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: Tenant Name: 12523 50 P1 S James A Codiga, Jr. King Co Assessor's Tax No.: 0179002885 Suite Number: Floor: New Tenant: ❑ Yes ..No PROPERTY OWNER Name: Sharyn Parker Address: 7277 Perimeter Rd S Name: James Codiga Jr. Phone: (206) 296-7437 Fax: Email: sharyn.parker@kingcountry.com Address: 12523 50 P1 S City: Tukwila State: WA Zip: 98178 CONTACT PERSON — person receiving all project communication Name: Sharyn Parker Address: 7277 Perimeter Rd S City:Seattle State: WA Zip: 98108 Phone: (206) 296-7437 Fax: Email: sharyn.parker@kingcountry.com MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: installation of (2) blending units Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ❑ Fuel Type: Electric 0 Gas ❑ Other: H:\Applications\Fornss-Applications On Line \2(11 I Applications\Mechanical Permit Application Revised (1-9-I I.docx Revised: August 2(111 bh Page I of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). � I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER ,! AU I RIZED AGENT: Signature: � � Date: 'V O- 41 -1.Q913 Print Name: othy Fenl.l.on Day Telephone: (206) 721-0061 Mailing Address: 1011 SW Klickitat Wy, Ste 208 Seattle WA 98108 City State H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Penni' Application Revised 8-9-I I.docx Revised: August 2011 bh Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT I QUANTITY I PAID $249.00 M13-0199 Address: 12523 50TH PL S Apn: 0179002885 $249.00 MECHANICAL $249.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $166.70 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R137 R000.322.102.00.00 $49.80 $'249.00 Date Paid: Monday, November 04, 2013 Paid By: PAMELA K KUEHL, KCIA (BY PHONE Pay Method: CREDIT CARD 002712 Printed: Tuesday, November 19, 2013 11:01 AM 1 of 1 CRWSYSTEMS S City of Tukwila Department of Community Development 6300 Southcenter Boulevard,Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 0179002885 Address: 12523 50 PL S TUKW Suite No: Applicant: CODIGA RESIDENCE RECEIPT Permit Number: M13-199 Status: PENDING Applied Date: 10/31/2013 Issue Date: Receipt No.: R13-03053 Initials: JEM User ID: 1165 Payment Amount: $249.00 Payment Date: 11/04/2013 04:05 PM Balance: $0.00 Payee: PAMELA K KUEHL, KCIA (BY PHONE) TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 002712 ACCOUNT ITEM LIST: Description 249.00 Account Code Current Pmts MECHANICAL - RES PLAN CHECK - RES 000.322.102.00.00 199.20 000.345.830 49.80 Total: $249.00 .I....• De..vi..4_/1R Prinfcrh 11_ A fllZ INSPECTION NO. INSPECTION RECORD Retain a copy with permit 041-019`1 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit. Inspection Request Line (206) 431-2451 Project: (1071(0.A 9--S". Type of Inspection: -? . Af 0, (ei -11..) , ` , Address: \ -.52 3 .., 0 r. la P L—. Date Called:\ . - et/1 '41,r , r-. / A-14 I Special Instructions: Date Wanted. 1 ( — Z.Z— I kalm. P.m. Requester: Phone No: EgApproved per applicable codes. Corrections required prior to approval. COMMENTS: Romc,h—�ry A 4 a r isul Date: 11_77— t RFtNSPECTION FEE REdUIRED. Prior'to next inspection, fee must be Lpaid at, 6300 Southcenter Blvd., Suite 100. Call toschedule reinspection. PERMIT COORD COPY. ( PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-199 DATE: 10/31/13 PROJECT NAME: CODIGA RESIDENCE SITE ADDRESS: 12523 50 PL S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ASS Building Division Public Works 4i14(\ re Preven ion Structural Planning Division nPermit Coordinator C DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete Complete 1Z DUE DATE: 11/05/13 Not Applicable n Comments: Permit Center. Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: Structural Review Required No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 12/03/13 Approved ❑ Approved with Conditions k Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople Pr er Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name S K M CONSTRUCTION INC UBI No. 601577401 Phone 4252355569 Status Active Address 14415 Se 143Rd Pl License No. SKMCOI*052L3 Suite/Apt. License Type Construction Contractor City Renton Effective Date 6/23/1995 State WA Expiration Date 12/30/2013 Zip 98059 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SKMCO"093L6 S K M CONSTRUCTION Construction Contractor General Unused 6/26/1991 6/17/1995 Archived SKMINI'976QL S K M INDUSTRIES INC Construction Contractor General Unused 11/13/2003 12/6/2009 Expired Business Owner Information Name Role Effective Date Expiration Date MORRISON, SHEILA K President 06/23/1995 Bond Amount MARKET SANDERS Agent 06/23/1995 06/25/2001 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FIRST NAIL INS CO OF AMERICA 6695979 06/17/2010 Until Cancelled $12,000.00 04/26/2010 4 DEVELOPERS SURETY & INDEM CO 188889C 12/30/2001 Until Cancelled 08/01/2010 $12,000.00 12/05/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 16 James River Ins 000495931 08/21/2012 08/21/2014 $1,000,000.00 08/19/2013 15 James River Ins 00049593 08/21/2011 08/21/2012 $1,000,000.00 08/18/2011 14 COLONY INS CO EPK300402 08/21/2010 08/21/2011 $1,000,000.00 08/20/2010 13 CENTURY SURETY CO CCP616634 08/21/2009 08/21/2010 $1,000,000.00 01/20/2010 12 AMERICAN STATES INS CO 01CH6810051 01/25/2009 01/25/2010 $1,000,000.00 01/23/2009 11 AMERICAN STATES INS CO 01CH6810051 12/30/2008 01/25/2009 $1,000,000.00 12/23/2008 10 AMERICAN STATES INS CO 01CH6810051 12/30/2007 12/30/2008 $1,000,000.00 12/07/2007 9 AMERICAN STATES INS CO 01CD87273820 12/30/2006 12/30/2007 $1,000,000.00 12/19/2006 httns://fortress.wa. aov/lni/bbin/Print.asnx 11/15/2013 ABBR EVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE. BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEC. DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM FT GA GAL GALV GPM •ORD GWB HP' H VAC HW FIWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MEG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING, BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING, CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING. EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE. FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD. HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWA'TT, (10Q0. WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL OAS NORMALLY OPEN NOT TO .SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION' POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER. MINUTE SUPPLY AIR. SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT' TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF' WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL xx ABBR OR XX 14 0 X/Y iir•••••••••MMII•M• DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX, LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE', NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR. VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.1 DETAILS M2.0 MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED, INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE, 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS. HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12 MAINTAIN 3"-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTZ: Revisions will require a new plan submittal and may include additional plan review fees, SYMBOL act72( XXX ABBR. 1111111111111111111 (4- 4 DN. UP VD RA/EA RG SA SA RA/EA SD DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VOLUME DAMPER RETURN AIR OR EXHAUST AIR DUCT RETURN AIR GRILLE SUPPLY AIR OUTLET. SIDEWALL SUPPLY AIR DUCT RETURN AIR OR EXHAUST AIR DUCT SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (:4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXftAUT AIR DUCT, EXHAUST AIR. ORILLE' TRANSITION — RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES $ SWITCH (zfR T, THERMOSTAT EQUIP ID# -.,---------- EQUIPMENT LOCATION NG 171 • MOD MOTOR OPERATED OAMPER, NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL/ELECTRICAL COORDIN ATION ITEM NO, EQUIPMENT CONTROL EQUIPMENT DESCRIPTION VOLTS PH FURN. SHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION 23: 26 23 26 BV -1,2 BLENDING UNIT VENTILATOR 120 1 X N/A 23 26 X N/A REMARKS 1,2 SWITCHES (ON, TIMER) 120 1 REMARKS! 1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 — DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL WATTS VOLTS PHASE COMMENTS By —i 140 • .5" WO 32"Lx12.25"Wx8.5"H 76 120 1 .BV —2 165 .5" WG 32"Lx12.25"Wic8. 5"H 76 120 1 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN! ALDES AMERICAN A. OR APPROVED EQUAL. 1, 2, 3 1, 2, 3 GRILLE AND DIFFUSER,: SCHEDULE„ MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS SG -1 140 <.08" WG 8' 8" WALL ALLGRILLE 1, 2, 4 SG -2 165 <08" WG 8" 8" CEILING ALLGRILLE 1, 2, 4 00-1 90 <.08" WG 8"X6" 8"X6" WALL WALL CAP 1, 2, 3, 4 OG -2 90 <08" WG 7" WALL WALL CAP RG -1 RG -2 25 <.08" WG 4" 4" WALL DECO 1, 2, 3, 4 1. 2, 4 25 <08" WG 4" 4" CEILING. DECO 1, Z 4 REMARKS!. 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. 5. BASIS OF DESIGN: 'SHOEMAKER A. OR APPROVED EQUAL 6. PROVIDE WITH AN OPPOSED BLADE DAMPER WAC RESIDENCE CODE FLOOR AREA (SQ. FT.) NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES '081'0..03.2334, 0810.03,2334 8V-2 825 2 90 CFM 90 CM 1 825 3 90 CFM 90 CFM 1 1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC), SECTION 51-51-1508, TABLES M1508.2 AND M1508,3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION MIN VALUE INOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING R-8 1,2,3 WITHIN CON DITIONED SPACE OR IN HEATED BASEMENTS R-8 1,3. IN CEMENT :OR IN GROUND R-5, 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR. 3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. DRAWING NOTES: 1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY, QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT. REFER TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT. 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. Fli&C.OPY in 1..610 Permit No. 31.1 " 1 PIn review approval is subject to errors and omissions. of construction documents does not authorize of any adopted code or ordinance. Receipt 41' roved Fl ld Copy and conditions is acknowledged: By Date: BV -1, BV -2 SWITCH City Of lbkwlla BUILDING DIVISION HOURS OF OPERATION SET THERMOSTAT/SWITCH TO OPERATE 1 OF EVERY 2 HOURS. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 0 5 2013 /f5— 14.4 City of Tukwila BUILDING DIVISION BV -1. BV -2M ECH ANICAL VENTILATION CALCULATION PER SRC M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE 1508.2) 4. &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF 45 / (1 X 1/2) = 90 CFM SEPARATE PERMIT raQUIRED FOR; 0 Mechanical argiectricai grAiumbing IiiIodas Piping City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 3 1 2013 PERMIT CENTER EXPIRES: 9/08/2014 S.M. STEMPER ARCHITECTS A nreffessional Waited larthilicfg Company 4000 ronRIDGE WAY SW SUITE 200 =ml. WA 02100 (goo) 4324-2777 ^ FAX (108) GE4.43073 THE GREENBUSCH GROUP, INC 4 4110**4 4))) sumwamis° siTEEIIIITE 201 SWIM 111iiS (201) 378-0809 (200) 370-0541 FAX 081003.2334 AIP NUMBER 3.53-0058-45 DATE 12/13/2012 ISSUED 1100% GD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX Ml. 081003.2334 RELOCATE (E) EXHAUST VENT TO THIS LOCATION (E) EXHAUST VENT, RELOCATE SEE UTILITY ROOM FAMILY ROOM RG -2 25 5EIDIROON 5 SOFFIT, REFER TO ARCHITECTURAL SG -1 140 1' tAll f3EDOON 4 RUN DUCT IN JOISTS LOWER FLOOR MECHANICAL PLAN SCALE: 1/4" = r-0" HOLD TIGHT TO STRUCTURE OUTSIDE AIR DUCT RETURN AIR DUCT FILTER ACCESS. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WM TECHNICAL REPRESENTATIVE (E)CEILI NG I. SUPPLY AIR DUCT SOFFIT MOTOR ACCESS NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTION'S. 2. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. (A7\_ BV— 1 INSTALLATION 17 SCALE: NONE DETAIL NADORTH CHASE, REFER TO ARCHITECTURAL MAIN FLOOR MECHANICAL PLAN SCALE: 1/4» FILTER. ACCESS HOLD TIGHT TO STRUCTURE OUTSIDE AIR. DUCT ------- " "-E•Ve ... .... ............. ATTIC SUPPLY DUCT COORDINATE ELECTRICAL. AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATI NOTES: 1. VERIFY UNIT ORIENTATION BEFOREl INSTALLATION. 2. INSTALL. PER MANUFACTURER'S WRITTEN INSTRUCTIONS. VE NaDORTH DRAWING N OTES: 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51, SECTION M1508.6.6. 2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEMS WITH NEW FILTERS, FLAG NOTES: 13V-1 AND DUCTWORK ROUTED IN SOFFIT. BV -2 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCHES WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 260010. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER WAC 51-51, SECTION M1508.6.4. COORDINATE FINAL SWITCH LOCATION WITH HOMEOWNER. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. NORTH REVIEWED FOR -CODE COMPLIANCE APPROVED NOV 0 5 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA OCT 3 1 2013 PERMIT CENTER EXPIRES: 9/00014 S.M. STEMPER ARCHITECTS A Profoodonal LimitedIbfWCompany 4000 DELRIDGE WAY. SW SUITE .200 SEATII.E, WA 90106 (200) 024-2777 • FAX (2oo) 024-2272 THE GREENBUSCH GROUP, WC 4000.0444 ))) ACOUS11CM. #1421 / 100120 *111021AMPL DANNEERINO 1000 VW 100,..M SIREET NOE MI MILE, 112 WM (200) 3711-0502 (200) 375-0041 FAX 0810.032334 MPROVEMENTS RESIDENTIAL AIR AIP NUMBER 3-53-0058-45 DATE 12/13/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO PRAWN JA, DT MECHANICAL PLANS AND DETAILS MV.. 0810.03.2334 SHEETMETAL TRANSITION TO WALL CAP NECK SIZE DUCT PER PLAN CAULK 2X BLOCKING. NOTES: 2X BLOCKING FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORD. WARCHITECTURAL TECHNICAL DOCUMENTS, REF. 1/A2.2 FOR DETAIL. WALL CAP DETAIL SCALE: NONE FLEX DUCT PER PLAN /I SOFFIT 2X2 BLOCKING, TYP 2X BLOCKING NOTES: TRANSITION TO WALL CAP NECK SIZE 2X BLOCKING SHEET METAL FLASHING WALL CAP (E)SIDING 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS. c"--"sk WALL CAP SCALE: NONE DETAI L CAULK SHEETMETAL TRANSITION TO' GRILLE NECK SIZE, DUCT PER PLAN 2X BLOCKING 2X BLOCKING FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. WALL GRILLE INSTALLATION DETAIL SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE 2X BLOCKING SLEEVE AND ESCUTCHEON: GRILLE DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE FOAM BACKER ROD •CAULK 2X. BLOCKING FLOOR OR CEILING JOIST CEILING NOTES: INSTALL PER mANUFACTuRER7S WRITTEN INsTRuCTIONs,. 2. SEE PLANS FOR VOLUME DAMPER LDCATIONS, 3. CEILING SUPPLY INSTALLATION sHowN,. RETuRN, SIMILAR. CEILING GRILLE DETAIL SCALE: NONE RECEIVED CITY OF TUKWILA OCT 3 1 2013 PERMIT CENTER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 05 2013 City of Tukwila BUILDING DIVISION I EXPIRES: 9/00/2014 S.M. STEMPER ARCHITECTS A Profeadonal Limited Liabiltiq Compazay 4000 DELRIDGE WAY SW SUITE 200 seam, WA uoloa (No ei48777 ^ PAZ Roo 0/14-2fla THE GREENBUSCH GROUP,INC 010060.0*** ))) Voulal" Auticiad° sreVr turraoi stuns, at UM (208) 378-0509 (200) 370-0041 FAX ce 0 0 eL 0 FT NOISE RE 0 CO AIP NUMBER 3-5$,0058-45 z 0 0 Cr) DATE 12113/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO PRAWN JA, DT DETAILS M2.1 0810.03.2334