HomeMy WebLinkAboutPermit M13-0199 - CODIGA RESIDENCE - ALTERATIONCODIGA RESIDENCE
12523 50 PL S
M13-0199
110
City of Tukwila
Department of Community Development
�,\ r 0 6300 Southcenter Boulevard, Suite #100
2 Tukwila, Washington 98188
1908 Phone: 206-431-3670 •
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No: 0179002885 Permit Number: M13-0199
Address: 12523 50TH PL S Issue Date: 11/15/2013
Permit Expires On: 5/14/2014
Project Name: CODIGA RESIDENCE
Owner:
Name: CODIGA JAMES A JR
Address: 12523 50TH PL S , SEATTLE, WA,
98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE, WA,
98108
Phone: (206) 296-7437
Contractor:
Name: S K M CONSTRUCTION INC Phone: (425) 235-5569
Address: 14415 SE 143 PL , RENTON, WA,
98059
License No: SKMCOI*052L3 Expiration Date: 12/30/2013
Lender:
Name:
Address:
DESCRIPTION OF WORK:
INSTALLATION OF (2) BLENDING UNITS
Valuation of Work: $4,644.00
Type of Work: NEW
Fuel type: GAS
Fees Collected: $249.00
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: TUKWILA
Sewer Distric: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012 International Fuel Gas Code:
2012 WA Cities Electrical Code:
2012 WA State Energy Code:
2012
2012
2012
2012
Permit Center Authorized Signature:
bp:A
Date: { V—tc 5
• •
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development permit and agree to the conditions attached to this permit.
Signature:
Print Name: DeN Ce
Date: t L 6 I S--)
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector
based on satisfactory completion of this requirement.
2: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
3: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
4: ***MECHANICAL PERMIT CONDITIONS***
5: All mechanical work shall be inspected and approved under a separate permit issued by the City of
Tukwila Permit Center (206/431-3670).
6: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: No changes shall be made to applicable plans and specifications unless prior approval is obtained from the
Tukwila Building Division.
9: All permits, inspection records and applicable plans shall be maintained at the job and available to the
plumbing inspector.
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the
City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or
other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1800 MECHANICAL FINAL
0609 PIPE/DUCT INSULATION
0701 ROUGH -IN MECHANICAL
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No.
Project No.
nnl27— 6 1
Date Application Accepted:
Date
Application Expires: oq 19J
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
Site Address:
Tenant Name:
12523 50 P1 S
James A Codiga, Jr.
King Co Assessor's Tax No.: 0179002885
Suite Number: Floor:
New Tenant: ❑ Yes ..No
PROPERTY OWNER
Name: Sharyn Parker
Address: 7277 Perimeter Rd S
Name: James Codiga Jr.
Phone: (206) 296-7437 Fax:
Email: sharyn.parker@kingcountry.com
Address: 12523 50 P1 S
City: Tukwila
State: WA
Zip: 98178
CONTACT PERSON — person receiving all project
communication
Name: Sharyn Parker
Address: 7277 Perimeter Rd S
City:Seattle State: WA Zip: 98108
Phone: (206) 296-7437 Fax:
Email: sharyn.parker@kingcountry.com
MECHANICAL CONTRACTOR INFORMATION
Company Name:
Address:
City:
State:
Zip:
Phone:
Fax:
Contr Reg No.:
Exp Date:
Tukwila Business License No.:
Valuation of project (contractor's bid price): $
Describe the scope of work in detail:
installation of (2) blending units
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement ❑
Fuel Type: Electric 0 Gas ❑
Other:
H:\Applications\Fornss-Applications On Line \2(11 I Applications\Mechanical Permit Application Revised (1-9-I I.docx
Revised: August 2(111
bh
Page I of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). �
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNER ,! AU I RIZED AGENT:
Signature: � � Date: 'V O- 41 -1.Q913
Print Name: othy Fenl.l.on Day Telephone: (206) 721-0061
Mailing Address: 1011 SW Klickitat Wy, Ste 208 Seattle WA 98108
City State
H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Penni' Application Revised 8-9-I I.docx
Revised: August 2011
bh
Zip
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
PermitTRAK
ACCOUNT
I QUANTITY I PAID
$249.00
M13-0199 Address: 12523 50TH PL S
Apn: 0179002885
$249.00
MECHANICAL
$249.00
PERMIT ISSUANCE BASE FEE
R000.322.100.00.00
$32.50
PERMIT FEE
R000.322.100.00.00
$166.70
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R137
R000.322.102.00.00
$49.80
$'249.00
Date Paid: Monday, November 04, 2013
Paid By: PAMELA K KUEHL, KCIA (BY PHONE
Pay Method: CREDIT CARD 002712
Printed: Tuesday, November 19, 2013 11:01 AM 1 of 1
CRWSYSTEMS
S
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard,Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
Parcel No.: 0179002885
Address: 12523 50 PL S TUKW
Suite No:
Applicant: CODIGA RESIDENCE
RECEIPT
Permit Number: M13-199
Status: PENDING
Applied Date: 10/31/2013
Issue Date:
Receipt No.: R13-03053
Initials: JEM
User ID: 1165
Payment Amount: $249.00
Payment Date: 11/04/2013 04:05 PM
Balance: $0.00
Payee: PAMELA K KUEHL, KCIA (BY PHONE)
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 002712
ACCOUNT ITEM LIST:
Description
249.00
Account Code Current Pmts
MECHANICAL - RES
PLAN CHECK - RES
000.322.102.00.00 199.20
000.345.830 49.80
Total: $249.00
.I....• De..vi..4_/1R Prinfcrh 11_ A fllZ
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
041-019`1
PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit. Inspection Request Line (206) 431-2451
Project:
(1071(0.A 9--S".
Type of Inspection:
-? . Af 0, (ei -11..) ,
` ,
Address:
\ -.52 3
.., 0 r. la P L—.
Date Called:\ .
- et/1 '41,r , r-. /
A-14 I
Special Instructions:
Date Wanted.
1 ( — Z.Z— I
kalm.
P.m.
Requester:
Phone No:
EgApproved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Romc,h—�ry
A 4 a r isul
Date:
11_77— t
RFtNSPECTION FEE REdUIRED. Prior'to next inspection, fee must be
Lpaid at, 6300 Southcenter Blvd., Suite 100. Call toschedule reinspection.
PERMIT COORD COPY. (
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: M13-199 DATE: 10/31/13
PROJECT NAME: CODIGA RESIDENCE
SITE ADDRESS: 12523 50 PL S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter # Revision # after Permit Issued
DEPARTMENTS:
ASS
Building Division
Public Works
4i14(\
re Preven ion
Structural
Planning Division
nPermit Coordinator C
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Incomplete
Complete 1Z
DUE DATE: 11/05/13
Not Applicable
n
Comments:
Permit Center. Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
TUES/THURS ROUTING:
Please Route
REVIEWER'S INITIALS:
Structural Review Required
No further Review Required ❑
DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 12/03/13
Approved ❑ Approved with Conditions k Not Approved (attach comments) n
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials:
Contractors or Tradespeople Pr er Friendly Page
•
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name S K M CONSTRUCTION INC UBI No. 601577401
Phone 4252355569 Status Active
Address 14415 Se 143Rd Pl License No. SKMCOI*052L3
Suite/Apt. License Type Construction Contractor
City Renton Effective Date 6/23/1995
State WA Expiration Date 12/30/2013
Zip 98059 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
SKMCO"093L6
S K M
CONSTRUCTION
Construction
Contractor
General
Unused
6/26/1991
6/17/1995
Archived
SKMINI'976QL
S K M INDUSTRIES
INC
Construction
Contractor
General
Unused
11/13/2003
12/6/2009
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
MORRISON, SHEILA K
President
06/23/1995
Bond Amount
MARKET SANDERS
Agent
06/23/1995
06/25/2001
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
5
FIRST NAIL INS CO OF
AMERICA
6695979
06/17/2010
Until Cancelled
$12,000.00
04/26/2010
4
DEVELOPERS SURETY
& INDEM CO
188889C
12/30/2001
Until Cancelled
08/01/2010
$12,000.00
12/05/2001
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
16
James River Ins
000495931
08/21/2012
08/21/2014
$1,000,000.00
08/19/2013
15
James River Ins
00049593
08/21/2011
08/21/2012
$1,000,000.00
08/18/2011
14
COLONY INS CO
EPK300402
08/21/2010
08/21/2011
$1,000,000.00
08/20/2010
13
CENTURY
SURETY CO
CCP616634
08/21/2009
08/21/2010
$1,000,000.00
01/20/2010
12
AMERICAN
STATES INS CO
01CH6810051
01/25/2009
01/25/2010
$1,000,000.00
01/23/2009
11
AMERICAN
STATES INS CO
01CH6810051
12/30/2008
01/25/2009
$1,000,000.00
12/23/2008
10
AMERICAN
STATES INS CO
01CH6810051
12/30/2007
12/30/2008
$1,000,000.00
12/07/2007
9
AMERICAN
STATES INS CO
01CD87273820
12/30/2006
12/30/2007
$1,000,000.00
12/19/2006
httns://fortress.wa. aov/lni/bbin/Print.asnx
11/15/2013
ABBR
EVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE.
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEC.
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
F
FD
FLA
FPM
FT
GA
GAL
GALV
GPM
•ORD
GWB
HP'
H VAC
HW
FIWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MEG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
SRC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING,
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING,
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING.
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE.
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD.
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWA'TT, (10Q0. WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL OAS
NORMALLY OPEN
NOT TO .SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION'
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER. MINUTE
SUPPLY AIR.
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
SEATTLE RESIDENTIAL CODE
TOTAL DYNAMIC HEAD
TOP OF DUCT'
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF'
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
xx
ABBR
OR XX
14
0
X/Y
iir•••••••••MMII•M•
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX,
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE', NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR. VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.1 DETAILS
M2.0 MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED, INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE,
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS. HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12 MAINTAIN 3"-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTZ: Revisions will require a new plan submittal
and may include additional plan review fees,
SYMBOL
act72(
XXX
ABBR.
1111111111111111111
(4-
4
DN.
UP
VD
RA/EA
RG
SA
SA
RA/EA
SD
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DUCT OFFSET DOWN IN
FLOW DIRECTION
DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VOLUME DAMPER
RETURN AIR OR EXHAUST AIR DUCT
RETURN AIR GRILLE
SUPPLY AIR OUTLET. SIDEWALL
SUPPLY AIR DUCT
RETURN AIR OR EXHAUST AIR DUCT
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(:4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXftAUT AIR DUCT, EXHAUST AIR. ORILLE'
TRANSITION — RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
$ SWITCH
(zfR T, THERMOSTAT
EQUIP ID# -.,---------- EQUIPMENT LOCATION
NG
171
•
MOD MOTOR OPERATED OAMPER,
NG NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL/ELECTRICAL COORDIN
ATION
ITEM
NO,
EQUIPMENT
CONTROL EQUIPMENT
DESCRIPTION
VOLTS
PH
FURN. SHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
23:
26
23
26
BV -1,2
BLENDING UNIT VENTILATOR
120
1
X
N/A
23
26
X
N/A
REMARKS
1,2
SWITCHES (ON, TIMER)
120
1
REMARKS!
1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 — DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
WATTS
VOLTS
PHASE
COMMENTS
By —i
140 •
.5" WO
32"Lx12.25"Wx8.5"H
76
120
1
.BV —2
165
.5" WG
32"Lx12.25"Wic8. 5"H
76
120
1
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN! ALDES AMERICAN
A. OR APPROVED EQUAL.
1, 2, 3
1, 2, 3
GRILLE AND DIFFUSER,: SCHEDULE„
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
SG -1
140
<.08" WG
8'
8"
WALL
ALLGRILLE
1, 2, 4
SG -2
165
<08" WG
8"
8"
CEILING
ALLGRILLE
1, 2, 4
00-1
90
<.08" WG
8"X6"
8"X6"
WALL
WALL CAP
1, 2, 3, 4
OG -2
90
<08" WG
7"
WALL
WALL CAP
RG -1
RG -2
25
<.08" WG
4"
4"
WALL
DECO
1, 2, 3, 4
1. 2, 4
25
<08" WG
4"
4"
CEILING.
DECO
1, Z 4
REMARKS!.
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS
2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE
3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN
4. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
5. BASIS OF DESIGN: 'SHOEMAKER
A. OR APPROVED EQUAL
6. PROVIDE WITH AN OPPOSED BLADE DAMPER
WAC
RESIDENCE CODE
FLOOR AREA
(SQ. FT.)
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
'081'0..03.2334,
0810.03,2334 8V-2
825
2
90 CFM
90 CM
1
825
3
90 CFM
90 CFM
1
1. VENTILATION PROVIDED PER THE WASHINGTON ADMINISTRATIVE CODE (WAC),
SECTION 51-51-1508, TABLES M1508.2 AND M1508,3
MINIMUM DUCT INSULATION THICKNESS
DUCT
LOCATION
MIN VALUE
INOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING
R-8
1,2,3
WITHIN CON
DITIONED SPACE OR IN
HEATED BASEMENTS
R-8
1,3.
IN CEMENT :OR IN GROUND
R-5,
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO CONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO UNCONDITIONED AIR.
3. REFER TO WASHINGTON STATE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
DRAWING NOTES:
1. ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS
RESIDENCE. THE CONTRACTOR REMOVING ACM SHALL REVIEW
THE EXECUTIVE SUMMARY REPORT AND LAB ANALYSIS FOR
EACH RESIDENCE INDICATED TO HAVE ACM PRESENT PRIOR TO
START OF WORK AND WILL BE RESPONSIBLE FOR OVERSEEING
ABATEMENT PROCEDURES. THE CONTRACTOR SHALL IDENTIFY,
QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT.
REFER TO SECTIONS 011101 AND 028200 FOR REGULATED
MATERIALS ABATEMENT.
2.
LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXTERIOR WINDOW TRIM PAINT.
Fli&C.OPY
in 1..610
Permit No. 31.1 " 1
PIn review approval is subject to errors and omissions.
of construction documents does not authorize
of any adopted code or ordinance. Receipt
41' roved Fl ld Copy and conditions is acknowledged:
By
Date:
BV -1, BV -2 SWITCH
City Of lbkwlla
BUILDING DIVISION
HOURS OF OPERATION
SET THERMOSTAT/SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 0 5 2013
/f5— 14.4
City of Tukwila
BUILDING DIVISION
BV -1. BV -2M
ECH
ANICAL VENTILATION CALCULATION
PER SRC M1508.3
QF = QR / (&EGR X F)
QR = (FROM TABLE 1508.2) 4.
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF 45 / (1 X 1/2) = 90 CFM
SEPARATE PERMIT
raQUIRED FOR;
0 Mechanical
argiectricai
grAiumbing
IiiIodas Piping
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
OCT 3 1 2013
PERMIT CENTER
EXPIRES: 9/08/2014
S.M. STEMPER
ARCHITECTS
A nreffessional Waited larthilicfg Company
4000 ronRIDGE WAY SW
SUITE 200 =ml. WA 02100
(goo) 4324-2777 ^ FAX (108) GE4.43073
THE GREENBUSCH GROUP, INC
4 4110**4 4)))
sumwamis° siTEEIIIITE 201 SWIM 111iiS
(201) 378-0809 (200) 370-0541 FAX
081003.2334
AIP NUMBER
3.53-0058-45
DATE
12/13/2012
ISSUED 1100% GD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
Ml.
081003.2334
RELOCATE (E)
EXHAUST VENT TO
THIS LOCATION
(E) EXHAUST
VENT, RELOCATE
SEE
UTILITY
ROOM
FAMILY
ROOM
RG -2
25
5EIDIROON
5
SOFFIT, REFER TO
ARCHITECTURAL SG -1
140
1'
tAll
f3EDOON
4
RUN DUCT IN
JOISTS
LOWER FLOOR MECHANICAL PLAN
SCALE: 1/4" = r-0"
HOLD TIGHT TO
STRUCTURE
OUTSIDE AIR
DUCT
RETURN AIR
DUCT
FILTER ACCESS.
COORDINATE ELECTRICAL
AND MAINTENANCE ACCESS
HATCH WM TECHNICAL
REPRESENTATIVE
(E)CEILI NG
I.
SUPPLY
AIR DUCT
SOFFIT
MOTOR ACCESS
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTION'S.
2. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
(A7\_ BV— 1 INSTALLATION
17 SCALE: NONE
DETAIL
NADORTH
CHASE, REFER TO
ARCHITECTURAL
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4»
FILTER. ACCESS
HOLD TIGHT TO
STRUCTURE
OUTSIDE AIR.
DUCT
------- " "-E•Ve ... .... .............
ATTIC
SUPPLY DUCT
COORDINATE ELECTRICAL. AND
MAINTENANCE ACCESS HATCH
WITH TECHNICAL REPRESENTATI
NOTES:
1. VERIFY UNIT ORIENTATION BEFOREl INSTALLATION.
2. INSTALL. PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
VE
NaDORTH
DRAWING N
OTES:
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR
3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER WAC 51-51,
SECTION M1508.6.6.
2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN
COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR
UNIT SYSTEMS WITH NEW FILTERS,
FLAG NOTES:
13V-1 AND DUCTWORK ROUTED IN SOFFIT. BV -2 AND DUCTWORK ROUTED
IN ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCHES
WITH TECHNICAL REPRESENTATIVE.
ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL
SPECIFICATIONS SECTION 260010. AFFIX A LABEL TO THE CONTROLLER
THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING
INSTRUCTIONS)" PER WAC 51-51, SECTION M1508.6.4. COORDINATE FINAL
SWITCH LOCATION WITH HOMEOWNER.
TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE
MAKING FINAL GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR
INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL
SPECIFICATIONS.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT
INSULATION THICKNESS SCHEDULE ON M1.0.
NORTH
REVIEWED FOR
-CODE COMPLIANCE
APPROVED
NOV 0 5 2013
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
OCT 3 1 2013
PERMIT CENTER
EXPIRES: 9/00014
S.M. STEMPER
ARCHITECTS
A Profoodonal LimitedIbfWCompany
4000 DELRIDGE WAY. SW
SUITE .200 SEATII.E, WA 90106
(200) 024-2777 • FAX (2oo) 024-2272
THE GREENBUSCH GROUP, WC
4000.0444
)))
ACOUS11CM. #1421 / 100120 *111021AMPL DANNEERINO
1000 VW 100,..M SIREET NOE MI MILE, 112 WM
(200) 3711-0502 (200) 375-0041 FAX
0810.032334
MPROVEMENTS
RESIDENTIAL AIR
AIP NUMBER
3-53-0058-45
DATE
12/13/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
PRAWN
JA, DT
MECHANICAL
PLANS AND
DETAILS
MV..
0810.03.2334
SHEETMETAL
TRANSITION TO WALL
CAP NECK SIZE
DUCT PER PLAN
CAULK
2X BLOCKING.
NOTES:
2X BLOCKING
FOAM BACKER
ROD
WALL CAP
SLEEVE AND
ESCUTCHEON
WALL
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORD. WARCHITECTURAL TECHNICAL DOCUMENTS,
REF. 1/A2.2 FOR DETAIL.
WALL CAP DETAIL
SCALE: NONE
FLEX DUCT
PER PLAN
/I
SOFFIT
2X2 BLOCKING,
TYP
2X BLOCKING
NOTES:
TRANSITION TO
WALL CAP
NECK SIZE
2X BLOCKING
SHEET METAL
FLASHING
WALL CAP
(E)SIDING
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS.
c"--"sk WALL CAP
SCALE: NONE
DETAI
L
CAULK
SHEETMETAL
TRANSITION TO'
GRILLE NECK SIZE,
DUCT PER PLAN
2X BLOCKING
2X BLOCKING
FOAM BACKER
ROD
WALL GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL DIFFUSERS AND GRILLES PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
WALL GRILLE INSTALLATION DETAIL
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
2X BLOCKING
SLEEVE AND
ESCUTCHEON:
GRILLE
DUCT PER PLAN
COORDINATE SOFFIT
WITH TECHNICAL
REPRESENTATIVE
FIELD FABRICATE
PLENUM BEHIND
CEILING GRILLE
FOAM BACKER ROD
•CAULK
2X. BLOCKING
FLOOR OR
CEILING JOIST
CEILING
NOTES:
INSTALL PER mANUFACTuRER7S WRITTEN INsTRuCTIONs,.
2. SEE PLANS FOR VOLUME DAMPER LDCATIONS,
3. CEILING SUPPLY INSTALLATION sHowN,. RETuRN, SIMILAR.
CEILING GRILLE DETAIL
SCALE: NONE
RECEIVED
CITY OF TUKWILA
OCT 3 1 2013
PERMIT CENTER
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 05 2013
City of Tukwila
BUILDING DIVISION
I EXPIRES: 9/00/2014
S.M. STEMPER
ARCHITECTS
A Profeadonal Limited Liabiltiq Compazay
4000 DELRIDGE WAY SW
SUITE 200 seam, WA uoloa
(No ei48777 ^ PAZ Roo 0/14-2fla
THE GREENBUSCH GROUP,INC
010060.0***
)))
Voulal" Auticiad° sreVr turraoi stuns, at UM
(208) 378-0509 (200) 370-0041 FAX
ce
0
0
eL
0
FT NOISE RE
0
CO
AIP NUMBER
3-5$,0058-45
z
0
0
Cr)
DATE
12113/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
PRAWN
JA, DT
DETAILS
M2.1
0810.03.2334