HomeMy WebLinkAboutPermit M13-0207 - BOEING #2-81 - ALTERATIONBOEING #2-81
8123 EAST MARGINAL
WAY S
M13-0207
City of Tukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No: 0001600020 Permit Number: M13-0207
Address: 8123 E MARGINAL WAY S 081 Issue Date: 12/4/2013
Permit Expires On: 6/2/2014
Project Name: BOEING #2-81
Owner:
Name: BOEING COMPANY THE
Address: PO BOX 3707 M/C 20-00 , SEATTLE,
WA, 98124
Contact Person:
Name: STEVE NIGHSWONGER Phone: (253) 867-1418
Address: 8657 S 190 ST BLDG F , KENT, WA,
98031
Contractor:
Name: DESIGN AIR, LTD. Phone: (253) 854-2770
Address: 8657 SOUTH 190TH ST , KENT, WA,
98031
License No: DESIGL*212DG Expiration Date: 3/7/2014
Lender:
Name:
Address:
DESCRIPTION OF WORK:
FURNISH AND INSTALL (1) FAN COIL UNIT, (3) TERMINAL UNITS, AND ALL ASSOCIATED DUCTWORK INCLUDING
GRDS INSULATION, TEST AND BALANCE, AND CONTROLS.
Valuation of Work: $225,000.00
Type of Work: REPLACEMENT
Fuel type: GAS
Fees Collected: $2,677.13
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: TUKWILA
Sewer Distric: TUKWILA SEWER SERVICE
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012 International Fuel Gas Code:
2012 WA Cities Electrical Code:
2012 WA State Energy Code:
2012
2012
2012
2012
Permit Center Authorized Signature:
Date: 4ctf3
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this
development per it and agree to the conditions attached to this permit.
Signature:
Print Name:
v
dpisktif),rr-
Date: ),Q /I//23
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if
the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: Readily accessible access to roof mounted equipment is required.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector based
on satisfactory completion of this requirement.
6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy
can be obtained at City Hall in the office of the City Clerk.
7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the City
of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other
ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
10: ***MECHANICAL PERMIT CONDITIONS***
11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center (206/431-3670).
12: Manufacturers installation instructions shall be available on the job site at the time of inspection.
13: ***FIRE DEPARTMENT PERMIT CONDITIONS***
14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328)
15: All new fire alarm systems or modifications to existing systems shall have the written approval of The
Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been
obtained. (City Ordinance #2328) (IFC 104.2)
16: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be
separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance
#2328)
• •
17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City
Ordinance #2328)
18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328)
19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required
for this project.
20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply
approval of such condition or violation.
21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention
Bureau at (206)575-4407.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
1400 FIRE FINAL
1800 MECHANICAL FINAL
0701 ROUGH -IN MECHANICAL
0702 SMOKE DETECTOR TEST
CITY OF TUK
Community Development Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
http://wwvv.TukwilaWA.gov
•
Mechanical Permit No. M
Project No.
Date Application Accepted: ' Z.. -
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
Site Address:
Tenant Name:
8Ia3
•7755 East Marginal Way South
The Boeing Company
PROPERTY OWNER
Name: Cele�efkitt5— 4 j-� o�
Name: The Boeing Company.
Cit': Kent State: WA Zip: 98031
Address: 100 North Riverside Plaza
Email: s.nighswonger@design-air.com
Cit': Chicago State: IL
Zip: 60606
CONTACT PERSON — person receiving all project
communication
Name: Cele�efkitt5— 4 j-� o�
Address: 8657 South 190th Street Bldg. F
Cit': Kent State: WA Zip: 98031
Phone.Fax: (253) 854-6131
Email: s.nighswonger@design-air.com
Valuation of project (contractor's bid price): $
Describe the scope of work in detail:
Furnish and install 1 Fan coil unit, 3 terminal units and all associated duct work including GRD's insulation, test and balance, and
controls.
225,000
King Co Assessor's Tax No.: 0001600020
Suite Number: 2-81 Floor: 1st
New Tenant: ❑ Yes Z ..No
MECHANICAL CONTRACTOR INFORMATION
Company Name: Design Air, Ltd.
Address: 8657 South 190th Street Bldg. F
City: Kent State: WA Zip: 98031
Phone: (253) 854-2770 Fax: (253) 854-6131
Contr Reg No.:600-314-241 Exp Date: 02/28/2014
Tukwila Business License No.: BUS -0994595
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement m
Fuel Type: Electric 0
Gas
Other:
H:\Appltcattons\Fornts-Applications On Line12011 Apphcatwns\Mechamcal Permit Application Revised 8-9-1 Ldocc
Revised: August 2011
bh
Page 1 of
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
.
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
4
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
.
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
4
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
4
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
Date: 11/11/2013
Print Name: Steven Nighswonger Day Telephone: (253) 854-2770
Mailing Address: 8657 South 190th Street Bldg. F Kent WA 98031
City State Zip
H:Wpplicat,ons\Forns-Applications On Line1201 I Apphcations\Mechanical Permit Application Revised 8-9-I 1.dowc
Revised: August 2011
bh
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS I ACCOUNT I QUANTITY
PermitTRAK
PAID
$2,834.01
M13-0207 Address: 8123 E MARGINAL WAY S 081 Apn: 0001600020
$2,677.13
MECHANICAL
$2,677.13
PERMIT FEE
000.322.100.00.00
$2,109.20
PERMIT ISSUANCE BASE FEE
000.322.100.00.00
$32.50
PLAN CHECK FEE
000.322.102.00.00
$535.43
PG13-0154 Address: 8123 E MARGINAL WAY S 081 Apn: 0001600020
$156.88,;
PLUMBING
$156.88
PERMIT ISSUANCE BASE FEE 000.322.100.00.00
$32.50
PERMIT FEE 000.322.100.00.00
$93.00
PLAN CHECK FEE 000.322.103.00.00
TOTAL FEES PAID BY RECEIPT: R70
$31.38
$2,834.01
Date Paid: Tuesday, November 12, 2013
Paid By: DESIGN AIR
Pay Method: CHECK 98501
Printed: Tuesday, November 12, 2013 10:34 AM 1 of 1
CRWSYSTEMS
INSPECTION RECORD_
Retain a copy with permit.
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd.,#100, Tukwila. WA 98188 (206) 431-3670
Permit. Inspection. Request Line (206) 431-2451
M/3 )Z7
Project: 1
t, e- 4 >a 2 'Er 1
Ty of Inspection:
(Co u 6 if -
PIe-�►•
\
Address:
Date Call d
Special Instructions:
Dat Wante .
A
'�
,d -4:,„..,f
p.m.
Requester:
Phone No:
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
P
eJ i( L -J
obc
ki)u6Th-
Ins Victor:
Date_ 0 - j ,y
n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy, with permit
INSPECTION NO. PERMIT NO.
CITY OFTUKWILA' BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA. 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
Po' t:
Type oUnspection: L
Ad es -
%.
Date. Called:
Special Instructions:
Date Wanted:-
12-(Z `( t ()
:
',m-
P.m.
Requester:
Phone No:
Approved per applicable codes.
COMMENTS:
Corrections required prior to approval.
,a.
C
.1,/,4" -elrt,e- <f ---
i'
3 ./
Date:
/j 7„,f"/
RE(NPECTION FEE RE'4UMRED. Prior.to next inspection.. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Callao schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO: PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION.
6300 Southcenter Blvd:, #100, Tukwila. WA 98188 (206).431-3670
Permit Inspection Request Line (206) 43.1-2451
Nit "3-0207:
Proje t.Type
OE t �V Z— /.
(-
of Inspection: _
r'Gntci !Pk _.
Address:
s,Z3 ,4,426,,011_
Date Called:
Special Instructions:
Destek) liiv(4-F4,--
3__5 S- Sal -2.770
c Ce- i.�i kc i S .
Date Wanted:
Z
i�C�
•
1
Cirri)
p.m.
Requester:
eA
NJ OT L e -r
Phone No:
- ng- G%0,1,50
JApproved per applicable codes. " Corrections required p'rior:to approval.
COMMENTS:
P4
/j(_: . //./0,,,
S
Inspect® / � ✓ ,
REINSPECTION FEE R QUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
I
Date:
fl- 6-13
INSPECTION NUMBER
INSPECTION RECORD
Retain a copy with permit
D/3- z
/3-5- 299
PERMIT NUMBERS
CITY OF TUKWILA FIRE DEPARTMENT
444 Andover Park East, Tukwila, Wa. 98188 206-575-4407
Project'
r, _ 2-•-01
Sprinklers:
Type of Inspection:
Srv\Z_ F/
/ �-
/ /' '
Address: `)
;Suite #: 53(2. 3 E-7:. t'it
') 113 A
!
Contact Per
n:
/
/
Special Instructions:
,�,
,t i ,f d
/
Phone No.:
A,0;,....,‘,5‹,/,./ -A--,,, �f
O x.c.f..e
4,�
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
it -..ti �lre /i C
/' (7�i-z- t
/
179 X
�
7":6 --- Fis...7^
`,
,�,
,t i ,f d
/
af/(.., Ai e
A,0;,....,‘,5‹,/,./ -A--,,, �f
O x.c.f..e
4,�
S'O'S c -s .s -77e//t-rt-7
''—
)rt #'i
R..1elu.) .. ,44c.vi ,_...
4/4'-w /),,,vdec.,
frs-vs_
...
e,,, ,7
,ovikr Peer,;(
— f/fd
("It.' 47 2.cif,4
_57.75,
,h_ 94
Needs Shift Inspection:
Sprinklers:
Fire Alarm:
Hood & Duct:
Monitor:
Pre -Fire:
Permits:
Occupancy Type:
Inspector?
Date: //a///
Hrs.:'
$100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from
the City of Tukwila Finance Department. Call to schedule a reinspection.
Billing Address
Attn:
Company Name:
Address:
City:
State:
Zip:
Word/Inspection Record Form.Doc
6/11/10
T.F.D. Form F.P. 113
THE BOEING CO M PA N
FILE COP CD
CE SHOP MOVE TO 02-81
Ran review approval ..peke to errors and a�iSSb a
Approval of construction documents does net a h, 123 E MA RG I NAL WAY
the violation of any adopted code or ordinance 4 ;r/ I LA, WASHINGTON 98 1 0 8
ackivwledB U I L D I N G 02-81
JOB # 19760
90% PERMIT SET
City Of 1Ukwila
BUILDING DIVISION
I\ REGIO\
MUKILTEO
TO EVERETT
Mill
0
LAND REE MOND
EVUE
rill" Hes
ISSAQUAH
- -----------
---_ 1
i
BOTHELL
t�
WOD
LYNN
DMON1:
B'
1 IV
_
,PROJECT
ON
--
SCALE:
SITE
�T�
EIAXEN
NONE _
ETON
.
1311
KENT
* •AUBURN
-===-=
TO
T•* A AUBURN
Y
SEPARATE PERMIT
REQUIRED FOR:
0 Mechanical
-Electrical
ta Plumbing
fil/Gas Piping
City of Tuk�»- la
BUILD DIV _ 1O y
CODES AND PERMITS
PERMITS REQUIRED & FOR REVIEW:
® BUILDING D GRADING
® PLUMBING * ❑ LANDSCAPE
▪ MECHANICAL* ❑ DEMOLITION
® ELECTRICAL * ❑ CIVIL
® FIRE PROTECTION * ❑ STRUCTURAL
* TO BE RENEWED UNDER SEPARATE PERMIT
WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE
COMPLIANCE OPTION
® PRESCRIPTIVE ® LPA ❑ ANALYSIS ❑ N/A
SPECIAL INSPECTIONS REQUIRED:
❑ WELD
❑ CONCRETE
❑ REBAR
O ANCHOR BOLTS
❑ STRUCTURAL BOLTING
❑ STRUCTURAL OBSERVATION
O OTHER
CALCULATIONS
TYPE: NRGC
ATTACHED (YES) (NO)
TAX PARCEL NUMBER: 112405-9134
vICI
ITY
VA
SE
3
2-41
2-40
2-44
a
2-5
2-49
2-66
2-65
2-64
I2-80
2-110 0
0
a
2-45
GATE B-18
SITE ACCESS
2-55 e
411.1
PROJECT SITE
SCALE: NONE
2-84
2-117
2-116
2-87
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
NOTE: Revisions will require a new plan submittal
and may include additional plan review fees.
LEGAL DESCIPTION
APN: 000160-0020
A TRACT OF LAND BETWEEN THE DUWAMISH WATERWAY AS ESTABLISHED BY
COMMERCIAL WATERWAY DISTRICT #1 OF KING COUNTY, WASHINGTON AND EAST
MARGINAL WAY IN SECTION 33, TOWNSHIP 24 NORTH, RANGE 4 EAST, W.M.,
AND IN THE JOHN BUCKLEY DONATION CLAIM NO. 42; SAID TRACT ALSO BEING
THE SOUTHERLY PORTION OF A LARGER TRACT COMMONLY CALLED THE BOEING
COMPANY'S PLANT NUMBER TWO SITE, DESCRIBED AS FOLLOWS:
BEGINNING AT THE SECTION CORNER COMMON TO SECTIONS 28, 29, 32,
AND 33; THENCE SOUTH 88'08'07" EAST ALONG THE NORTH LINE OF SAID
SECTION 33, A DISTANCE OF 982.00 FEET TO AN INTERSECTION WITH THE
SOUTHWESTERLY MARGIN OF EAST MARGINAL WAY; THENCE SOUTH 4751'53"
EAST ALONG SOUTHWESTERLY MARGIN 684.62 FEET TO THE TRUE POINT OF
BEGINNING OF THE TRACT HEREIN DESCRIBED; THENCE SOUTH 4725'24"
WEST 1215.02 FEET MORE OR LESS TO A POINT ON THE NORTHEASTERLY MARGIN
OF SAID DUWAMISH WATERWAY, SAID POINT BEING ON A CURVE FROM WHENCE
THE CENTER BEARS SOUTH 4716'23" WEST 1969.12 FEET; THENCE SOUTH-
EASTERLY ALONG SAID CURVE, A DISTANCE OF 397.99 FEET TO THE POINT
OF INTERSECTION WITH A LINE LYING 825.00 FEET SOUTH, AS MEASURED AT
RIGHT ANGLES, OF THE NORTH LINE OF THE JOHN BUCKLEY DONATION LAND
CLAIM NO. 42. THENCE SOUTH 89'09'36" EAST ALONG SAID LINE,
PARALLEL WITH THE NORTH LINE OF SAID DONATION LAND CLAIM NO. 42,
A DISTANCE OF 1387.45 FEET TO THE WESTERLY MARGIN OF EAST MARGINAL
WAY; THENCE NORTH 2732'15" WEST 160.30 FEET, FOLLOWING SAID
WESTERLY MARGIN TO THE POINT OF CURVATURE OF A CURVE HAVING A RADIUS
2828.00 FEET; THENCE NORTHWESTERLY ALONG SAID CURVE, A DISTANCE OF
1250.10 FEET TO THE POINT OF TANGENCY OF SAID CURVE; THENCE NORTH
4751'53" WEST 76.82 FEET TO THE TRUE POINT OF BEGINNING: THIS
TRACT CONTAINING AN AREA OF 2,897,955 SQUARE FEET, MORE OR LESS.
REVItVVED FOR
CODE COMPLIANCE
APPROVED
NOV 27 2013
City of :u ila
BUILDING VISION
RECEIVED
CITY OF TUKWILA
NOV ,1 2 2013
PERMIT CENTER
CODE SUMMARY
TYPE OF APPLICATION: NEW ❑ ALTERATION ❑ ADDITION ❑. TENANT IMPROVEMENT
NARRATIVE:
10,275 SF OF TENANT IMPROVEMENT OF THE INTERIOR ONLY ON THE FIRST FLOOR
OF THE 02-81 BUILDING. DEMOLITION WILL INCLUDE THE REMOVAL OF
FLOOR/CEIUNG FINISH MATERIALS, NON -LOAD BEARING WALLS, PLUMBING FIXTURES
AND PORTIONS OF THE HVAC, ELECTRICAL AND PLUMBING. SYSTEMS. TENANT
IMPROVEMENT WILL INCLUDE NEW WALLS, CEILINGS, AND FLOOR COVERINGS. NEW
MECHANICAL, HVAC, PLUMBING AND FIRE PROTECTION SYSTEMS WILL BE INSTALLED
PLUS ELECTRICAL POWER, LIGHTING COMMUNICATION AND DATA SYSTEMS TO SUPPORT
THE NEW LAYOUT. IN ADDITION A EXTERIOR PAIR OF DOORS ON THE WEST
ELEVATION WILL BE INSTALLED.
CODES: 20 INTERNATIONAL BUILDING CODE (WAC 51-50)
20 INTERNATIONAL FIRE CODE (WAC 51-54)
70 INTERNATIONAL MECHANICAL CODE (WAC 51-52)
20 PLUMBING
N
WASHINGTON STATE ENERGY CODE AND YCODE (WAC 5WAC 51-
2 6 ICC/ANSI A117.1
2 3 ICC A117.1 ACCESSIBILITY CODE
C RENT CITY OF TUKWILA ZONING ORDINANCES
ORIGINAL CODE:
OWNER- THE BOEING COMPANY .
CONTRACTOR & STATE NUMBER- TO BE DETERMINED
BOEING PROJECT MANAGER: MICHAEL PRITTIE
PROJECT DESIGN
ARCHITECT / ENGINEER: ERWIN C. ANGULO, DLR GROUP 206-461-6000
206-304-0027
BOEING CONTACT: MICHAEL PRITTIE PHONE- 206-304-0027
FAX NUMBER- TBD
E-MAIL MICHAELJ.PRIT11E1280EING.COM
ZONING CITY OF TUKWILA
OCCUPANCY GROUP. Fl FACTORY INDUSTRIAL
CONSTRUCTION TYPE- II -B
ALLOWABLE AREA INCREASE- -
OCCUPANT LOAD: (ALLOWABLE) SEEA3FOR FLOOR AREA: 62,828 SF/ FLOOR
OCCUPANT LOAD: (ACTUAL) PROJECT CODE INFO (PER SECTION 502 DEFINITION OF
BUILDING AREA)
OFFICES OCC - BLDG GROSS 125,656
STORAGE DCC - BASEMENT
ASSEMBLY OCC - FIRST FLOOR
CANOPY OCC - SECOND FLOOR
OTHER - OCC = THIRD FLOOR
PENTHOUSE OCC = FOURTH FLOOR
BUILDING HEIGHT: (ACTUAL) UNCHANGED
FIFTH FLOOR
SIXTH FLOOR
PENTHOUSE
PROJECT AREA
SQ FT
SQ FT
62,828 SQ FT
62,828 SO FT
SO FT
SO FT
SO FT
SO FT
SO FT
10,275 SO FT
STORIES- 2 MEZZANINE ? ® (YES) 0 (NO) SQ FT 1 265SF
FIRE PROTECTION: SPRINKLERED THROUGHOUT ® (YES) 0 (NO)
NFPA 13 AUTOMATIC SPRINKLER SYSTEM IS INSTALLED WITH QUICK RESPONSE HEADS.
SEPARATION 2 HOUR AT EXISTING BUILDINGS AND GRID 17 (02-80/02-81)
EXTERIOR WALL (NON-BEARING) HOUR RATING
EXTERIOR WALL (BEARING) HOUR RATING
INTERIOR WALL (NON-BEARING) HOUR RATING
INTERIOR WALL (BEARING) HOUR RATING
DEMOUNTABLE PARTITIONS HOUR RATING
STRUCTURAL FRAME HOUR RATING
FLOOR/CEIUNGS HOUR RATING
ROOF CONSTRUCTION HOUR RATING
SEISMIC CATEGORY: ZONE D
DESIGN LOADS: (CHAPTER 23)
ROOF: LIVE (SNOW) (PSF)
FLOOR: OFFICE (PSF)
MECH/STOR (PSF)
STAIRS (PSF)
PENTHOUSE (PSF)
CONCENTRATED.
WIND: EXPOSURE
NOTE: FOR ADDITIONAL CODE INFORMATION SEE COMPOSITE CODE PLAN SERIES A3
DLR Group
90% SUBMITTAL
ISSUED FOR PERMIT
555
REVISION
BI
ORIO
CDC RELOCATION - WIRE SHOP RELOCATION J/19760
DLR GROUP
APPROVED
EEA
DATE
5YM
REVISION
APPROVED
DATE
10.22.13
LBOE/Ar4r
ACCEPTABILITY
THI5 DESIGN AND/OR
SPECIFICATION IS APPROVED
DEPT. DATE
DIRWN
DATE
=RED
SUBTITLE
COVER SHEET
CURRENT REVISION
J#19760
SRBUEQRIG
DATE 10.22.13
APPROVED BY
NLMELH
'CHECKED
APPROVED
APPROVED -
TITLE
WIRE SHOP RELOCATION TO 2-81
VICINITY MAP, LEGAL DESCRIPTION
AND CODE SUMMARY
ARCHITECTURAL MASTER
PLANT2, WA
SHEET
GO
JOB NO.
19760
COMP NO.
DWG NO.
2 -81 -GO
AA WfYLO1
[JUGULO: 10/22/201
LEGEND/SYMBOLS
MATERIAL SYMBOLS
;
ABBREVIATIONS
GENERAL NOTES
PLAN
FROM)
SPECIFIC
MOUNTED)
MOUNTED)
EMERGENCY
FIXTURE
FIXTURE
EMERGENCY
__.
DIRT, COMPACTED
GRAVEL. POROUS
COMMON
TILE
FILL
LOOSE FILL BLANKET
GROUT
WALL BOARD
BLOCKING
MASONRY (CMU)
1
STUD
STUD
)
I
I
(
(7'-0- HIGH)
j
p FOR (
����
I
• (
f .
I
(
i
,
1
J
1
I
i
(
& AND IN INCH
0 Al WCL INCLUDED(D) (INC)
AB ANCHOR BOLT JT JOINT
ACP ACOUSTICAL CEILING PANG
ACT ACOUSTICAL CEIING 111.E K KIP(S)
ADI ADJACENT • KO KNOCK OUT
AFF ABOVE FINISHED FLOOR Lto LENGTH
AL AGGREGATE
AL ALUMINUM LENGTH
ALT ALTERNATE LEN
ALUM ALUMINUM LF LINEAL FEET
ARCH ANCHOR, ANCHORAGE LWR Ll COAD
AN AMERICAN PLYWOOD ASSOC.
APPD APPROVED
MARL MATERIAL
APPROX APPROXIMATE
MAX 50X1505
ADM AMERICAN SORELY OF MB MACHINE BOLT
TESTING MATERWS
MBR MEMBER
BTWN BETWEEN MR METAL
BLDG BUILDING MFR MANUFACTURE(R)
BLKG BLOCKING MIN MINIMUM
BD BOTTOM OF 5150 MISCELLANEOUS
801 BOLTON MO
MT MASONRY OPENING
MOUNT(ED) (INC)
C CHANNEL MTL METAL
CB CATCH BASIN
CC CENTER TO CENTER N NORTH (COORDINATE)
CEM CEMENT NF NEAR FACE
CF CUBIC FEET NIC NOT IN CONTRACT
CFO CONTRACTOR FURNISHED CONTRACTOR INSTALLED NO. NUMBER
CG CORNER GUARD NOM NOMINAL
CJ CONTROL JOINT NTS NOT TO SCALE
CL CENTER UNE
CLG CEILING OA OVERALL
CUR CLEAR(MCE) 0/0 ON CENTER
COL COLUMN OD OUTSIDEDIAMETER
COMP COMPRESS(ED)OTHERWISE.
(ION) or OUTSIDE FACE
CONC CONCRETE 010 OWNER FURNISHED CONTRACTOR INSTAIIID
CONN CONNECTION OF01 OWNER FURNSHED OWNER INSTATED
CONST CONSTRUCTION OPG OPENING
COM CONTINUOUS, CONTINUE OPP OPPOSITE. OPPOSITE HAND
COR IOM PARALLEL
CT CERAMIC TILE RCC PRECAST CONCRETE
CTSK COUNTERSUNK PCF POUNDS PER CUBIC FOOT
CY CUBE YARD(S) PERF PERFORATE(D)
IL, DA DIAMETER PERIM PERIMETER
DBL DOUBLE PO PATTERN GLASS
00501 DEMOLISH, DEMOLITION PL PLATE
DEP DEPRESSED PLANT PLASTICLAMINATE
DIA DIAMETER PLYWD PLYWOOD
DAG DIAGONAL PNL PANE
DIM DIMENOON PRES1 PRE SII¢SS(ED)
DL DEAD LOAD PRF PREFORMED
DN DOWN PSI POUNDS PER SQUARE FOOT
DS DOWNSPOUT P51 POUNDS PER SQUARE INCH
DWG DRAWING PT POINT, PAINT
PVC POLYVINYL CHLORIDE
E EAST (000RDNATE)
EA EACH R RADIUS (CURVATURE)
EB EXPANSION BOLT R RISER
EF EACH FACE RB RESILIENT BASE
EJ EXPANSION ,ENT REF REFERENCE, REFER TO
EL ELEVATION REINF REINFORCE(D) (INC)
EILY ELEVATION REO REQUIRE(D) (INC)
00 EQUALREV REVERSE, REV510N(5). REVISED
EIV EACH WAY RH RIGHT HMD
EX EXISTING RO ROUGH OPENING
EEXP EXPOSED XT EXTERIER 5 SOUTH (COORDINATE)
SECT SECTION
FAS FASTEN(ER) SF SQUARE FEET
FE FIRE EXTINGUISHER SHT SHEET
FEC FIRE EXTINGUISHER CABINET SIN SIMILAR22.
FF FINISHED CEILING SO SQUARE
FF FACTORY FINISH SS SOLID SURFACING
FF FINISHED FLOOR SST STAINLESS STEEL
FOR FINISH GRADE Si STRUCTURAL TEE
FH FIRE HYDRANT STD STANDARD
FIN FTNISH(ED) SR STEEL
END FOUNDATION STR STRUCTURAL
FOC FACE OF CONCRETE SYR SYMUETRY,SYMUETRICAL
FOF FACE OF FINISH SYS SYSTEM
T&B TOP AND BOTTOM
FDIC FURNISHED BY OWNER/ T&G TONGUE AND GROOVE
INSTALLED BY CONDUCTOR
TEMP TEMPORARY
FO FINISHED OPENING
THK THICK(NESS)
FRO FOR REFERENCE ONLY TOC TOP OF CURB
FT FOOT TOC TOP OF CONCRETE
FTG FOOTINGTOLTOLERANCE
FUT FUTURE 15$ STP OF STEEL
N FIELD VERIFY 15 STRUCTURAL TUBE
GA GAGE lYP mica.
GREG GLASS FIBER REINFORCED GYPSUM
GM GALVANIZED UBC UNIFORM BUILDING CODE
GC GENERAL CONTRACTOR UL UNDERWRITERS' LABEL
GI GALVANIZED IRON 0NO UNLESS NOTED OTHERWISE
UPR UPPER
CR GRADE
GT GROUT VB VAPOR BARRIER
ORB GYPSUM WALL BOARD VC VINYL COMP. TILE
VERT AREAL
HOAR HARDENER NF VERIFY IN FIELDRCP'S,
H0WR081D HARDWOOD W WEST (COORGNATE)
HOwR HARDWARE W WIDE FLANGE
HG HIGH GRADE W WIDTH, WIDE
HM HOLLOW METAL WC WATER CLOSET
HOE HORIZONTAL WD WOOD
HS HIGH STRENGTH
W/0 WITHOUT
HT HEIGHTW/0
WELDED WIRE FABRIC
INC INTERNATIONAL
ID INSIDENSIDE DIAMETER BLDG. CODE NOTE: REFER TO THE COLOR AND DLR
ID INSIDE DIMENSION MATERIAL SCHEDULE FOR ADDITIONAL t,,„•,,,,,. 1„s,,,,�,,,,Y
FINISH AND
IF INSIDE FACE DESIGNATIONS ABBREVIATIONS
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
Group
r1,,,..,s ,m,...,
OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE CITY OF KENT PRIOR TO
COMMENCING CONSTRUCTION.
VERIFY ALL EXISTING CONDm0N5 AND NOTIFY THE BOEING PROJECT CONSTRUCTION MANAGER
SHOULD CONDITIONS DIFFER FROM DESIGN DOCUMENTS.
THE SCOPE OF WORK INCLUDES AU. WORK WEAN THE CURRENT REVISIONCI0UD(S ON EACH
SHEET. IF THERE IS NO CLOUD ON A SHEET THE ENTIRE SHEET IS W THE SCOPE OF WORK.
INFORMATION OR WORK (WHETHER CLOUDED OR NOT) REFERRED TO FROM WITHIN A CLOUD
INCLUDED IN THE SCOPE OF WORK (I.E. - A SECTION OR DETAIL SYMBOL THAT UES WITHIN
CLOUD ON A PLAN NEW SHEET IS INCLUDED IN THE SCOPE EVEN WHEN THE ACTUAL SECTION
DETAIL DRAWN ON INC DETAIL. SHEET IS NOT CLOUDED.)
KEEP ALL MEAS UNDER CONSTRUCTION CLEAR OF DEBRIS CAUSED BY THIS SCOPE OF WORK.
STORE CONSTRUCTION MATERIALS AND EQUIPMENT 1N AREA DESIGNATED BY THE BOEING PROJECT
CONSTRUCTION MANAGER.
VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND ENSURE THAT THE JOINING
OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. BRING DISCREPANCIES ON THE
DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION
MANAGER IMMEDIATELY UPON DISCOVERY. THE CONTRACTOR SHALL ADVISE BOEING. SUMMARIZE
THE SITUATION MD PROVIDE RECOMMENDATIONS TO RESOLVING POTENTIAL CONFLICTS PRIOR
SUBMITTING ANY REQUESTS FOR INFORMATION (RE0s).
CONFORM ALL WORK TO APPLICABLE CODES. REGULATIONS AND INDUSTRY STANDARDS.
COMPLY W1111 THE BOEING PROJECT CONSTRUCTION MANAGER FOR CONSTRUCTION AREA AND
SECURITY REGULATIONS.
PROVIDE, AS IF DRANK IN FULL, REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE
DRAWINGS.
DIMENSIONS ON DRAWINGS ME TAKEN TO THE FACE OF MASONRY AND/OR CONCRETE WALLS,
METAL STUDS, AND TO THE CENTERLINE OF COLUMNS, UNLESS OTHERWISE NOTED.
DOOR OPENINGS ARE 6- FROM ADJACENT WALLS OR CENTERED IN ROOM WALL, UNLESS
DIMENSIONED OTHERWISE.
PARTITIONS 5551 RUN FIAT HEIGHT, FROM FLOOR TO FLOOR ABOVE UNLESS SHOWN OR NOTED
PLANS WHICH APPEAR AS -BACKGROUNDS- ON CML, STRUCTURAL PLUMBING, HVAC, ELECTRICAL
DRAWINGS ETC., ARE FOR THE PURPOSE ONLY OF ILLUSTRATING GENERAL PLM CONFIGURATION.
SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER TWIN THAT
PERTSMNG TO THE TIRE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH
SPECIFIC PORTION OF THE WORK.
COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL
AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC TRADE REQUIREMENTS.
COORDINATE ALL ROUGH -IN REQUIREMENTS FOR EQUIPMENT FURNISHED BY CONTRACTOR OR
OTHERS FOR THIS PROJECT.
PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT CONSTRUCTION
MANAGER WHENEVER SUCH INSTRUCTIONS ARE REFERENCED IN THE CONSTRUCTION NOTES.
CONTRACTOR SHALL COORDINATE WITHTHE BOEING PROJECT CONSTRUCTION MANAGER FOR
STAGING MEAS WHERE CONTRACTOR CLAY STORE SALVAGED MATERIALS TO BE REUSED IN LATER
PMTS OF THIS PROJECT AND WHERE MATERIALS TO BE STAGED BY BOEING ME TO BE LOCATED.
SYMBOLS SHOWN ON MATERIALS UST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING
MATERIAL AND SEE CONSTRUCTION NOTES FOR MATERIAL CALL0U15.
WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED AS A RESULT OF DEMOLITION OR
PERFORMANCE OF NEW WORK, THE CONTRACTOR IS TO PATCH M0 REPAIR THE EXISTING TO
MATCH ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL
BEAR UNES SUCH AS CORNERS, CEILING ONES, TOP OF BASE, CHANGE IN MATERIAL OR
ALL RECESSES LOCATED w1MIN FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN
REQUIRED FIRE PARK OF THE PARTITION.
ARCHITECTURAL REFLECTED CERING PLANS INDICATE THE FINAL LOCATIONS OF MECHANICAL
ELECTRICAL COMPONENTS. SEE THE REFLECTED CEILING PLANS FOR LOCATIONS OF ITEMS
CEILING; SEE DSCIPLINE SHEETS FOR ALL INFORMATION ABOUT THE MECHANICAL AND ELECTRICAL
COMPONENTS INDICATED ON ARCHNECTURAL REFLECTED CLUNG PLANS.
PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN
FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS AND ALL PENETRATING DUCTS, PIPES,
CONDUIT, MECHANICAL, ELECTRICAL- AND OTHER ITEMS.
THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AND
ELECTRICAL DRAWINGS FOR CUTTING AND PATCHING WORK WITHIN THE BUILDING, BEYOND THE
WATTS OF THE ARCHITECTURAL DRAWINGS.
AT METAL STUD PARTITIONS. STUDS ARE TO EXTEND FROM FLOOR TO FLOOR U.N.O.. WHERE
DO SO. DUE TO INTERFERENCE WITH NEW OR EXISTING DUCTS, PIPING, ETC., PROVIDE
BRACING TO STRUCTURE MOVE TO PROVIDE FOR EQUIVALENT SUPPORT OF PMIRION; SUBMIT
EQUIVALENT SUPPORT METHOD TO ARCHITECT FOR REVIEW. ALL FRE RATED PARTMONS SHALL
CONSTRUCTED TO MAINTAIN THEIR RATING FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE,
U.N.O.
PROVIDE ACCESS DOORS AS INDICATED DR A5 NECESSARY AND VERIFY WITH MECHANICAL AND
ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS REQUIRED BY THEIR WORK. ACCESS
MUST BE PROVIDED FOR ALL CONCEALED VALVES. DAMPER CONTROLS. FIRE DAMPER LINKAGES,
CONCEALED JUNCTION 80005, AND ELECTRICAL DEVICES OR ACCESSOR ES. LOCATIONS AND
Of EXPOSED ACCESS DOORS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR
INSTALLATION OF THE MECHANICAL AND ELECTRICAL EQUIPMENT.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE
WITH ALL SAFER' CODES, REGUMRONS AND BOEING REQUIREMENTS.
THE CONTRACTOR SHALL RETAIN A FIRE PROTECTION ENGINEER LICENSED IN THE STATE OF
WASHINGTON TO DETERMINE/DESIGN THE MODIFIED FIRE SPRINKLER SYSTEM LAYOUT WTIMN
AREA OF WORK. SAID ENGINEER SHALL STAMP, SEM AND CERTIFY THAT HIS/HER DESIGN IS
COMPLIANCE W/011 APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL COORDINATE
NECESSARY M0DIFICA1TONS AS A RESULT OF SAID ENGINEER'S DESIGN.
THE CONTRACTOR SHALL INSURE THAT THE ELEVATOR CAR, EOUIPMENT ROOM, EQUIPMENT LAYOUT
AND HYDRAULIC ELECTRICAL ROUTING FULLY MEETS STATE OF WASHINGTON CODES AND
/
COMPLIANCE. FULLY COORDINATE WITH ARCHITECT PRIOR TO FABRICATION AND INSTALLATION.
AT LOCATIONS WHERE STRUCTURE. PIPING. DUCTWORK, CABLETRAY, OR CONDUIT PENETRATES
WALLS MD ARE EXPOSED TO VIEW. CONTRACTOR SHALL COPE AS CLOSELY AS POSSIBLE TO
MEMBER AND INSTALL CONTINUOUS CAULKING AROUND MEMBER AND PAINT OR PROVIDE
ESCUTCHEONS MATCHING WALL COLOR AT PENETRATIONS.
FOR CONSISTENCY ALL CONSTRUCTION NOTES ('FUG NOTES") FOR EACH GROUP: PLAN AND
ME SHOWN IN THEIR ENTIRETY. ALL CONSTRUCTION NOTES MAY NOT BE REFERENCED
EERYTTY
FRAME TYPES ARE TYPICALLY DRAWN LOOKING FROM THE OUTSIDE OR KORNER SIDE
15
A
OR
TO
BY
SIMILAR,
AND
IN THE
ALL
THEY
BE
SIZES
TO
THE
IN
All
THE
n
ON Il E C E I V
OF TU
0.
NOV 1 2 ,
CE
SECTION/DETAIL DESIGNATION
BUILDING, WALL SECTIONS
n -MM -MM -n-.
8=nn-u-u- EMIR,
flEggEMEE STONE.
X r0 AND DETAIL REFERENCES
SHEET NUMBER WHERE DETAILED
SHEET NUMBER REFERENCED FROM
%" ii•" % BRICK.
{Tf }} i}7}j CERAMIC
/ INTERIOR ELEVATION REFERENCE
•
AX X B
SHEET NUMBER WHERE DETAILED
SHEET NUMBER REFERENCED FROM
N i REFERENCE TO DETAIL/ENLARGED
CONCRETE
BATT,
DIRT, UNDISTURBED
RICO
BRONZE, COPPER
STEEL. IRON
SEND, CEMENT,
GYPSUu
FINISH
ROUGH CONTINUOUS
INTERRUPTED
SMALL SCALE
LARGE SCALE
TYPE: CONCRETE
TYPE: STEEL
TYPE: WOOD
TYPE: EXISTING
TYPE REMOVAL
TYPE: PARTITION
TYPE: GLASS
COMPLIANCE
����
2
of T.�.1T
BIIAIIUIUUht1!II�1�iL INSULATION:
14.11:ACW0C4AN EARTH,
INSULATION:
IX X 8 L
DETAIL DESIGNATION
Ml
r//,‘ // ,VA ALUMINUM
�•"- - i BRASS,
Ia.
fy�TMl✓ SHEET NUMBER WHERE DETAILED
OF SAME A5 SHEET REFERENCED
V� SECTION/DETAIL DESIGNATION
1. s"/// . .,,A METAL,
I - I PLASTER:
)3(XX`XXXXX SHEET NUMBER WHERE DETAILED
SHEET NUMBER REFERENCED FROM
N NORTH ARROW
ELEVATION DAVM
(- - I PLASTER:
1 1 1 W000:
C WOOD:
OR SPOT ELEVATION
(XIX) CEILING HEIGHT A.F.F.
XXXXXX R00M NAME
11/000:
WOOD:
® PLYWOOD:
XXXX I ROOM NUMBER
MSE:'.:'.:: i3MS, 11110001):
® DOOR NUMBER
��
(\
` _ GRID/GRID BUBBLE AND
CENTERLINE
ITEMS TO BE REMOVED
CONSTRUCTION -FLAG- NOTE FOR
CONSTRUCTION DIRECTIVE
GENERAL -BOAT- NOTE FOR
SPECIFIC OR EXISTING HISTORICAL1
INFORMATION
( J( WINDOW FRA1AE TYPE
>
\\
X/� PARTDION/WALL TYPE
•
I��F
I END WALL GUARD
--- ���111
p CORNER GUARD
I
E ',/../..... 'X' '. %I WALL
1 ''.. WALL
® WALL
1WAIL
WALL
1 I WALL
u n WALL
REVIEWS
L. •
ODE
APPR
) , �/
1` NOV
'
r(
• Citv
1•
BUILDINNIGHT
( CPT -1) FINISH DESIGNATION
REVISION CLOUD WITH
REVISION 111115 'BEAK'
A
VCT CPT
FLOOR MATT iRANSTTION
LEO FIRE EXTINGUISHER
['ICI] FIRE EXTINGUISHER & CABINETMJ
M�}y
FyI Q e SUPPLY AIR DIFFUSER
•. .•••-,•Ilk. n RETURN AIR GRILLE
FLOURESCENT LIGHT FIXTURE
R 6 (PENDANT
D I FLOL'RESCENT LIGHT FIXTURE (PENDANT
FLOURESCENT UGHi FIXTURE ON
p
LIGHT (NL) CRCUH
O RECESSED OR PENDANT LIGHTING
R RECESSED OR PENDANT LIGHTING
• FLOURESCENT UGHT FIXTURE ON
NIGHT UGHT (NL) CIRCUIT
=OCT WALL SCONCE 1
6 NMI SCONCE 2
H EXIT SIGN (WALL MUNIT)UNI(
1-631 EXIT SIGN (WALL MOUNT)
90% SUBMITTAL
ISSUED FOR PERMIT R M I T
PERMIT
STA
REVISION
S
APPROVED
DALE
MIA
REV610N
B1.
ARMED
OAll
I
I
B�E,�”
T
®
5188
ACCEPTABILITY
155 DESIGN AND/OR
SPECIFICATION 5 APPROVED
PRA 14
DLR CROUP
DATE
04.04.08
5UBTRLE
KEY SHEET
CURRENT REVISION SYMBOL
JH19760 ORIG
DATE
10.22.13
ORIG
CDC RELOCATION - WIRE SHOP RELOCATION J.19760
DER GROUP
ECA
10.22.13
REGISTERED
ARCHITECT
LD • • KRUSE
T_ DF AS 1145005
LHE
D. RED
N00
04.04.08
SHEETG1
APPROV DB
DEP .DA
£WEERT
LE WIRE SHOP RELOCATION TO 2-81ii
2-81 BUILDING
ARCHITECTURAL MASTER PLANT2, WA
CHECKED
APPROVED
JOB N0.
19760
COMP N0.
APPROVED
0 WG NO, 2-81-01
ED
KWILA
X013
1\1TER
i
I\ D I- X 01- D RAW
\ G S
ISSUE LEGEND
INCLUDED
SET
I DRAWING
NO.
SHEET NO.
DRAWING SUBTITLE
REV
DATE
INCLUDED
INS SET
DRAWING
NO.
SHEET NO.
1
DRAWING SUBTITLE
REV
DATE
INCLUDEDI
IN SET
I DRAWING NO.
SHEET NO.
DRAWING SUBTITLE
REV
DATE
NOT YET ISSUED
1IN
_ _ PREVIOUSLY ISSUED FOR
CONSTRUCTION
GENERAL
ARCHITECTURAL
o PREVIOUSLY ISSUED, BUT
RE IUSIN THIS 13
NOT IN
O SE
• 02 -81 -GO
GO
VICINITY MAP, LEGAL DESCRIPTION AND CODE SUMMARY
ORIG
10-22-13
• 02-81-A3
A3
COMPOSITE FIRST FLOOR PLAN
A
10-22-13
• 02-81-M1M456
M1M456
MEZZANINE DUCTWORK
A
10-22-13
• INCLUDED IN THIS ISSUE
• 02-81-G1
G1
KEY SHEET
ORIG
10-22-13
• 02-81-G2
G2
INDEX
ORIG
10-22-13
• 02-81-1Al2
1Al2
FLOOR PLAN
D
10-22-13
• 02-81-M506
M506
HVAC DETAILS
A
10-22-13
• 02-81-1A13
1A13
FLOOR PLAN
D
10-22-13
• 02-81-M513
M513
PLUMBING DETAILS
A
10-22-13
PREL
PRELIMINARY ISSUE
FOR REVIEW OR
• 02-81-M1Al2
M1Al2
MEZZANINE LAYOUT PLAN
A
10-22-13
• 02-81-UGM455
UGM455
ENLARGED PLUMBING PLAN
B
10-22-13
INFORMATION ONLY
ARCHITECTURAL REMOVALi
• 02-81-1A282
1A282
REFLECTED
NOT FOR CONSTRUCTION
• 02-81-1Al2R
1Al2R
FLOOR PLAN
D
10-22-13
CEILING PLAN ;
I
A
10-22-13
FOR REFERENCE
• 02-81-1A13R
1A13R
FLOOR PLAN
D
10-22-13
• 02-81-1L12
1L12
LAYOUT PLAN j
ORIG
10-22-13
ONLY
ORIG
ORIGINAL ISSUE
• 02-81-1L13
1L13
LAYOUT PLAN I
ORIG
10-22-13
02 -81 -MO
MO
LEGEND
-
11-12-99
FOR PERMIT, BID,
• 02-81-M1Al2R
M1Al2R
MEZZANINE LAYOUT PLAN
A
10-22-13
PROCUREMENT OR
CONSTRUCTION
• 02-81-A60
A60
EXTERIOR ELEVATIONS
A
10-22-13
• 02-81-1A282R
1A282R
REFLECTED CEILING PLAN
A
10-22-13
02-81-A351
A
DRAWING REVISION -
• 02-81-1L12R
1L12R
LAYOUT PLAN
ORIG
10-22-13
•
A351
DOOR SCHEDULE
ORIG
10-22-13
ELECTRICAL
SEE SPECIFIC DRAWING
• 02-81-1L13R
1L13R
LAYOUT PLAN
ORIG
10-22-13
• 02-81-A453
A453
STAIR NO 2 PLAN
FOR NATURE OF
• 02-81-A458
A458
AND SECTION
FINISH PLAN
A
10-22-13
• 02 -81 -ED
EO
ELECTRICAL LEGEND
A
10-22-13
REVISION
• 093-818-2L1OR
2L10R
LAYOUT PLAN
ORIG
10-22-13
• 02-81-A459
A459
FINISH PLAN
ORIG
A
10-22-13
10-22-13
• 02-81-1E2
1E2
480Y/277 VOLT POWER
A
10-22-13
• 093-818-2L11R
2L11R
LAYOUT PLAN
ORIG
10-22-13
• 02-81-1E3
1E3
208Y/120 VOLT POWER
A
10-22-13
FOR REFERENCE ONLY
02-81-A350
A350
WALL TYPES
-
11-12-99
• 2-YD-V50E4
E4
ONE -LINE DIAGRAM - VAULT 50
B
10-22-13
02-81-A501
A501
DETAILS
-
11-12-99
• 02-81-1E12
1E12
LIGHTING
C
10-22-13
02-81-A504
A504
DETAILS
-
11-12-99
STRUCTURAL REMOVAL
02-81-A507
A507
DETAILS
-
11-12-99
• 02-81-1E62
1E62
208Y/120 VOLT POWER
C
10-22-13
• 02-81-RFE110
RFE110
ROOF 480/277 VOLT POWER
B
10-22-13
• 02-81-1E112
1E112
480Y/277 VOLT POWER
A
10-22-13
• 02-81-1E161
1E161
400 HZ 200Y/115 VOLT POWER
A
10-22-13
STRUCTURAL
• 02-81-1E162
1E162
400 HZ 200Y/115 VOLT POWER
ORIG
10-22-13
MECHANICAL REMOVAL
• 02-81-S1A
S1A
GENERAL STRUCTURAL NOTES
ORIG
10-22-13
• 02-81-1E212
1E212
CMCS PLAN
D
10-22-13
• 02-81-1M12R
1M12R
DUCTWORK REMOVAL
C
10-22-13
• 02-81-1S62
1S62
PARTIAL FIRST FLOOR SLAB PLAN
A
10-22-13
• 02-81-1E262
1E262
SMOKE DECTECTOR / ADT
A
10-22-13
• 02-81-1M11OR
1M11OR
PLUMBING REMOVAL
A
10-22-13
• 02-81-S412
S412
STRUCTURAL DETAILS
ORIG
10-22-13
• 02-81-1E362
1E362
TELECOMMUNICATION
B
10-22-13
REVIEWED
• 02-81-1M112R
1M112R
PLUMBING REMOVAL
C
10-22-13
FOR
1
_
• 02-81-E500
E500
LIGHTING FIXTURE SCHEDULE
B
10-22-13
CODE COMPLIANCE
• 02-81-1M262R
1M262R
FIRE PROTECTION REMOVAL
B
10-22-13
• 02-81-E501
E501
ELECTRICAL PARTIAL PLANS
A
10-22-13
APPROVED
• 02-81-M311R
M311R
HVAC FLOW DIAGRAM REMOVAL
A
10-22-13
• 02-81-M331R
M331R
CMCS MISCELLANEOUS SYSTEM CONTROLS
A
10-22-13
FOR REFERENCE ONLY
NOV
02-81-E510
E510
COMMUNICATION DETAILS
-
11-12-99
2 7 2013
• 02-81-M454R
M454R
CAFETERIA & KITCHEN PLUMBING REMOVAL
C
10-22-13
02-81-E511
E511
FIRE ALARM RISER DIAGRAM
-
11-12-99
MECHANICAL
02-81-E512
E512
FIRE ALARM DETAILS
-
11-12-99
• 02-81-M1M456R
M1M456R
MEZZANINE DUCTWORK REMOVAL
A
10-22-13
02-81-E513
E513
CONTROL SCHEMATICS
-
11-12-99
• 02-81-M1A
M1A
EQUIPMENT SCHEDULE
B
10-22-13
02-81-SK33G101713
SK33G
400 HZ PERMISSIVE & STINGER RECEPT
-
11-12-99
City of Tukwila
• 02-81-M515R
M515R
FIRE PROTECTION DETAILS
A
10-22-13
• 02-81-M1B
M1B
EQUIPMENT SCHEDULE
A
10-22-13
02-81-2E115
2E115
480Y/277 VOLT POWER
11-12-99
• 02-81-M1C
MIC
EQUIPMENT SCHEDULE
A
10-22-13
BUILDING DIVISION
• 02-81-UGM455R
UGM455R
PARTIAL PLUMBING PLAN REMOVAL
B
10-22-13
• 02-81-M2
M2
GENERAL NOTES
A
10-22-13
• 02-81-1M12
1M12
DUCTWORK
C
10-22-13
• 02-81-1M62
1M62
HVAC PIPING
A
10-22-13
ELECTRICAL REMOVAL
• 02-81-1M110
1M110
PLUMBING
A
10-22-13
• 02-81-1E2R
1E2R
408/277 VOLT POWER
A
10-22-13
• 02-81-1M111
1M111
PLUMBING
B
10-22-13
• 02-81-1E3R
1E3R
208/120 VOLT POWER
A
10-22-13
• 02-81-1M112
1M112
PLUMBING
C
10-22-13
• 02-81-1E12R
1E12R
LIGHTING
C
10-22-13
• 02-81-1E62R
1E62R
208Y/120 VOLT POWER
C
10-22-13
• 02-81-1M262
1M262
FIRE PROTECTION
B
10-22-13
• 02-81-1E112R
1E112R
480Y/277 VOLT POWER
A
10-22-13
• 02-81-1M263
1M263
FIRE PROTECTION
B
10-22-13
• 02-81-1E212R
1E212R
CMCS PLAN
D
10-22-13
• 02-81-1E262R
1E262R
SMOKE DECTECTOR / ADT
A
10-22-13
• 02-81-RFM3
RFM3
DUCTWORK AND HVAC PIPING
B
10-22-13
• 02-81-1E362R
1E362R
TELECOMMUNICATIONS
0
10-22-13
G 02-81-M310
M310
HVAC CONTROL SEQUENCES
B
10-22-13
• 02-81-M311
M311
HVAC FLOW DIAGRAM
A
10-22-13
• 02-81-M319
M319
CHILLED WATER PIPING DIAGRAM
A
10-22-13
• 02-81-M321
M321
FIRST FLOOR HEATING WATER PIPING DIAGRAM
A
10-22-13
RECEIVED
• 02-81-M327
M327
AHU-6 P & ID
A
10-22-13
DLR Group CITY OF TUKWILA
• 02-81-M330
M330
TERMINAL EQUIP P & ID
A
10-22-13
• 02-81-M454
M454
ENLARGED PLUMBING PLAN
C
10-22-13
NOV 2 2013
90% SUBMITTAL
ISSUED FOR PERMIT
PERMIT CENTER
$YM
fiVNON
BY
APPROVED
MTE
BYM
REVISION
BY
ApPRDyTO
DATE
ACCEPTABILITY
DRAWN
DATE
SUE..
CURRENT REVISION
STYROL
DATE
(RIG
CDC RELOCATION - WIRE SHOP RELOCATION J}19760
OLR CROUP
ECA
10.22.13
51yy
ARCHITECT'
THIS DESIGN AND/OR
E. ANGULO
CHIC KED
09.05.13
INDEX
��197so
I
1D 2213
off
sPECIF1CAnON Is APPROVED
E. ANGULO
ENGINEER
09.05.13
SHEET
0
®
APPROVED BY
DEPT.
DATEWIRE
TITLE
SHOP RELOCATION TO 2 81
A 2
g)LardirAw,Arc1
'CHECKED
=OT AS IT1 „APPROVED
BUILDING 2-81
JOB NO.
19760
COMP NO.
s
APPROVED
ARCHITECTURAL MASTER PLANT2, WA
DWG NO. 2-81-G2
AIR HANDLERS
MARK NO.
SERVICE/LOCATION
SUPPLY FAN
RETURN FAN
FILTERS
I CHILLED WATER COIL
TOTAL
BTUH
SENSIBLE
BTUH
CFM
FUTURE
CFM
PRESENT
1OIAL SP
IN WINTER
ESP
IN. WTR
FAN
RPM
BHP
MOTOR
HP
FAN
TYPE
DRIVE
CFM
ESP
N. WTR
FAN
RPM
BHP
MOTOR
HP
FAN
TYPE
DRIVE
% EFFICIENCY'
VEL CI
141AX5
EAT DB��ApT WB
DEC FIDEG F
LAT DR
DEGIF
AT WB
DEC F
EWF
DEC F
LWT
DEC F
CAPACITY
MBH
FACE
VELOCITY
GPM
CONTROL VALVE
DELTA P
WPD
FT WER
APD
FT WTR
FPI
ROWS
PRE I FINAL
F
AHU-1
2ND FLR NORTH/ROOF
43,450
39,500
5.25
2.15
(2)1/10
120
60
PLUG
BELT
39,035
1.0
PLTITUS ENUM 2-PIPEE FAN COIL
160
15
PLUG
BELT
30
85
500
75.5
61.1
52:9
51.5
45
55
1084
500
210
5 PSIG
6.8
0.70
8
6
AHU-2
2ND FLR SOUTH/ROOF
46,815
42,560
4.25
1.12
34,000
PROVIDED BY BOEING
60
PLUG
BELT
43,470
0.75
-
-
15
PLUG
BELT
30
85
500
75.1
61.0
5219
51.5
45
55
1019
500
204
5 PSIG
7 6
0.78
8
6
AHU-3
2ND FLR CORE/ROOF
23,925
21,750
4.50
1.27
40
PLUG
BELT
20,515
1.0
7.5
PLUG
BELT
30
85
500
77.1
62.3
52.9
51.5
45
55
673
500
135
5 PSIG
39
0.68
8
6
AH -4
T R OF
57,570
52,3
4.50
1.46
75
PLUG
BELT
47,330
1.75
15
PLUG
BELT
30
85
500
75.2
61.0
52 9
51.5
45
55
1274
500
255
5 PSIG
8 4
0.75
8
6
> AHU-5
1ST FLOOR SE/MEZZ.
8 5
8,385
4.00
3.46
1944
7.73
10
PLUG
BELT
7,440
0.5
598
1.03
3
PLUG
BELT
30
85
500
81.2
66.3
53.4
52.8
45
55
283
500
56
5 PSIG
4 9
0.61
8
6
o. AHU-6
1ST FLOOR SE/MEZZ.
8,440
7,350
4
1150
4.3
7.5
CENT
BELT
-
-
-
30
500
85
55
45
55
441
500
88
5 PSIG
3 8
0.74
8
6
NOTES: 1. REPLACE EXISTING MOTOR AT AHU-6 WITH NEW INVERTER DUTY MOTOR OF EQUAL S ZE, HORSEPOWER AND RPTA, COGPATI BLE WFTTi VFD OPERATION.
FAN COIL SCHEDULE
MARK
NUMBER
LOCATION
SERVICE
CFM
ESP
IN W.G.
MIN
OA CFM
TOTAL
BTUH
SENSIBLE
BTUH
COOLING COIL
(QTY)HP MOTOR
VOLTAGE
FILTERS I
REMARKS
EDB
DEC F
EWB
DEG F
LOB
DEG F
LWB
DEC F
EWE
DEC F
LWTWpp
DEC F
GPM
WG
ROWS
MEDIA
TYPE
EFF
MAX
MAX DECTAP IN W.G.
%
FPM
CLEAN
DIRTY
,FCU -1-01
E.1/4.0
ELECTRICAL ROOM
850
0.2
0
33,300
23,400
78
65
55
53
45
55
6.6
6.3
4
(2)1/10
120
DISPOSABLE
30
400WITH
.25
NOTE 1
PLTITUS ENUM 2-PIPEE FAN COIL
CABINET UNIT HEATERS
MARK NO.
SERVICE
FAN
HOT WATER HEATING
MANUFACTURER/MODEL
REMARKS
OUTSIDE
MINIMUM
RETURN
MAXIMUM
CFM
MOTOR
HP
DRIVE
COIL CAPACITY
MBH
EWE
DEG F
LWT
DEG F
CPM
MAX WPD
FT
36,305
EF -01
CUH-01
LOBBY VESTIBULE
50
1/30
DIRECT
2.76
180
160
0.28
0.1
INTERNATIONAL FSY-C2
NOTE 1
CUH-02
NORTHWEST VESTIBULE
50
1/30
DIRECT
2.76
180
160
0.28
0.1
INTERNATIONAL FSY-C2
NOTE 1
CUH-03
NORTHEAST VESTIBULE
50
1/30
DIRECT
2.70
180
160
0.28
0.1
INTERNATIONAL FSY-C2
NOTE 1
NOTES:
1. ALL FAN MOTORS ARE: 120 VOLTS, 1 -PHASE, 60Hz.
EXHAUST FANS
MARK NO.
SERVICE
LOCATION
FAN
TYPMANUFAC URER/MODEL
REMARKS
OUTSIDE
MINIMUM
RETURN
MAXIMUM
RETURN
MINIMUM
CFM
E.S.P.
in W.C.
FAN
RPM
BHP
MOTOR
HP
DRIVE
3,195
36,305
EF -01
T(aT�¢NB�1 ORS
ROOF
4880
1.0
625
0.65
3/4
BELT
ROOF EXHAUSTER
. ,
39,520
EF-
AHU-6 RELIEF/MEZZ
OOF
7350
21,750
65
.39
7.5
E
RELIEF AIR FAN FOR AHU-6
GRFFNHFCK CURF '160 HP
AHU-4
> EF -08
NOT USED
52,335
9,310
43,025
8,080
43,025
0
AH -
:,3:
00.
> EF -09
NOT USED
7 E:
7,1:E
,08
160
AHU-6
7,350
2,250
7,350
2,250
EF -10
L IC1 H•
1ST FLR
CEILING
500
3.18
-
-
1 2
/
DIRECT
D .�0
EXTRACTOR
87
0. 0 •T
EF -12
TRANDUCER & CALIBRATION FAC.
ROOF
335
4.0
-
-
1/3
BELT
34,000
PROVIDED BY BOEING
EF -13
ELECTRICAL SHOP
1ST FLR
CEILING
500
4.08
-
-
1.0
DIRECT
NEDERMAN 5000
EXTRACTOR
7 FOOT EXTRACTOR ARM
EF -14
HYDRAULIC RM
WALL
100
0.125
1500
-
0.1
DIRECT
CENTRIFUGAL FAN
ZEPHYRS. MODEL Z3H
PROVIDE 277/115V TRANSFORMER
EF -15
DATA RMS & ELECT RMS
ROOF
2150
0.25
634
0.20
1/4
BELT
ROOF EXHAUSTER
PENN -VENTILATOR, DX169
NOTE 1
NOTES: 1
9
2. REPLACE EXISTING MOTOR AT EF -05 WITH NEW INVERTER DUTY MOTOR OF EQUAL SIZE, HORSEPOWER AND RPM, COMPATIBLE WITH VFD OPERATION.
:_IJ FOR
)MPLIANCE
ROVED
7 2013
'; Tukwila
)(BUT: lIVISION
CONSTRUCTION NOTES
EXISTING EQUIPMENT TO BE REBALANCED TO
AIRFLOWS INDICATED IN THIS SCHEDULE.
PROVIDE NEW EOUIPMENT AS SCHEDULED.
PRESENT DESIGN AIRFLOWS
MARK NO.
CFM
WEIGHT
SUPPLY
MAXIMUM
SUPPLY
MINIMUM
OUTSIDE
MAXIMUM
OUTSIDE
MINIMUM
RETURN
MAXIMUM
RETURN
MINIMUM
RELIEF
MAXIMUM
RELIEF
MINIMUM
AHU-1
39,500
15,800
39,500
3,195
36,305
12,805
36,305
0
AHU-2
42,560
17,025
42,560
3,040
39,520
13,385
39,520
0
AHU-3
21,750
8,700
21,750
3,100
18,650
6,800
18,650
0
AHU-4
62,335
17,400
52,335
9,310
43,025
8,080
43,025
0
AH -
:,3:
00.
: 85
ors
7 E:
7,1:E
,08
160
AHU-6
7,350
2,250
7,350
2,250
5,100
0
7,350
2,250
a
AIR HANDLERS
MARK NO.
HOT WATER HEATING COIL
WEIGHT
MANUFACTURER
REMARKS
REMARKS
EAT
DEC F
LAT
DEC F
EWE
DEC F
LWT
DEC F
CAPACITY
MBH
FACE
VELOCITY
GPM
CONTROL VALVE
DELTA P
WPD
FT WTR
APD
FT WTR
FPI
ROWS
LBS.
UH -03
INSTRUMENTATION VAN STAGING
AHU-1
56
87
180
160
290.2
500
29.0
5 PSIG
5.4
0.13
6
2
32,500
TEMTROL
NOTE 1, 2
AHU-2
56
87
180
160
287.6
500
28.8
5 PSIG
4.3
0.13
6
2
32,500
TEMTROL
NOTE 1, 2
AHU-3
56
87
180
160
205.7
500
20.6
5 PSIG
2.5
0.11
6
2
27,000
TEMTROL
NOTE 1, 2
AHU-4
56
87
180
160
193.3
500
19.3
5 PSIG
4.8
0.13
6
2
34,000
TEMTROL
NOTE 1, 2
AHU-5
56
87
180
160
246.3
500
15.0
5 PSIG
1.6
0.11
6
2
10,000
TEMTROL
NOTE 1
AHU-6
21
59
180
160
292.2
500
30.0
5 PSIG
1.1
0.11
6
2
13,000
TEMTROL
NOTE 1
NOTES: 1. ALL FAN MOTORS ARE: 1760 RPM, 480 VOLTS, 3-PHASE, 60Hz.
2. AHU 1, 2, 3 & 4- SUPPLY AND RETURN AIRFLOWS INCLUDE 10% FUTURE CAPACITY.
UNIT HEATERS
MARK NO.
SERVICE
FAN
HOT WATER HEATING
MANUFACTURER/MODEL
REMARKS
RPM
HP
CFM
RPM
MOTOR
HP
DRIVE
COIL CAPACITY
MBH
E
DEG F
LWT
DEG F
GPM
MAX WPD
FT
SUMP PUMP
10
UH -03
INSTRUMENTATION VAN STAGING
1340
1625
1/8
DIRECT
59.5
180
160
6.3
1.4
MODINE, MODEL HS -86
NOTE 1, 2
UH -04
INSTRUMENTATION VAN STAGING
1340
1625
1/8
DIRECT
59.5
180
160
6.3
1.4
MODINE, MODEL HS -86
NOTE 1, 2
UH -05
INSTRUMENTATION VAN STAGING
1340
1625
1/8
DIRECT
59.5
180
160
6.3
1.4
MODINE, MODEL 1-15-86
NOTE 1, 2
UH -06
NOT USED
UH -07
SHIPPING AND RECEIVING
1120
1550
1/12
DIRECT
42.3
180
160
4.7
0.8
MODINE, MODEL HS -63
NOTE 1, 2
NOTES: 1 UNIT HEATERS WERE SIZED BASED ON MODINE, MODEL HS -XX. EQUIVALENT OR GREATER THAN UNIT HEATERS
MAY BE SUBMITTED FOR APPROVAL BY THE ENGINEER.
2 ALL UNIT HEATER FANS ARE: 120 VOLTS, 1 -PHASE, 60Hz.
PUMP SCHEDULE
PUMP NO.
LOCATION
SERVES
FUNCTION
GPM
HEAD FEET
RPM
HP
ELECTRICAL
WEIGHT
LBS.
MANUFACTURER
MODEL
REMARKS
VOLTS I PHASE I Hz
P-10
INSTRUMENTATATION
SUMP
SUMP PUMP
10
25
-
4/10
120 1 60
-
LITTLE LI
9E -CIA -RFS
20' POWER CORD j
NOTES: 1. PUMP WEIGHT DOES NOT INCLUDE THE INERTIA BASE.
2. PUMPS WITH VFD DRIVES SHALL HAVE VFD COMPATIBLE MOTORS.
COMPUTER ROOM COOLING UNIT (CRU) SCHEDULE I
MARK
NUMBER
LOCATION
(ROOM NUMBER)TYPE
NOMINAL
CAPACITY
TONS
FAN
FAN MOTOR
COIL COOLING CAPACITY
CHILLED WATER '
HUMIDIFIER
ELECTRIC
REHEAT
COIL
AIR FILTER
REMARKS
DRNE TYPE
CAPACITY
(CFM)
ESP IN WG
HP
CAPACITY MBH
ROOM TEMP 'f
FLOW
GPM
EWE
'F
MAX. PD 0 MAX
FLOW FT! H2O
CAP
#/HR
KW
TYPE &
DEPTH
EFFICENCY
PER ASHRAE
52-76
MAX
FINAL
SP WG
SENSIBLE
TOTAL
DB
WB
CRU -2D4
LIEBERT UH147C
7
BELT
5250
.3
2.0
88
88
75
61
18.6
45
33.8
-
-
-
20
4-18X24 FILTERS
CRU -2
- RECORD DRAWING
A INSTALL POWER & COOLING
4972197-00
./577800-01
B CDC RELOCATION - WIRE SHOP RELOCATION 419760
HCI/SHS
11.12.99
10.25.07
10.22.13
I
ACCEPTABILITY DRAWN OPNESS -DATE12.97
THIS DESIGN AND/DR RIL'KLDLIN 3.30.98
SPECIFICATION 6 M'PROJED S.
NWNEEN
APPROVED BT DEPT. DATE C. RAVEN 11.12.97
CHE KED
C. SPRAGUE
6.3.98
SUBDNE
EQUIPMENT SCHEDULE
RECEIVED
CITY OF TUKWILA
NOV 1 2 2013
PERMIT CENTER
90% SUBMITTAL
ISSUED FOR PERMIT
-
fah\�.
Wood
CURRENT REVISION
4.19760
SYMBOL
B
DATE
3009 Mrth roe NE
Suite leo
Be9eNle wA98R 4
05.6386mo
wcodhartingencwo
10.22.13
L. PROVED
COSTELLO
6.3.98
APPROVED
R. MCNIESH
6.3.98
mit
MECHANICAL MASTER
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
PLANT 2
MIA
JOB NO.
972197-00
COMP NO.
DRD NO.
2-81-M1A Page 4 of 27
TERMINAL UNITS
J
EQUIPMENT
TAG
INLET SIZE
IN.
SUPPLY AIR CFM
REO'D MAX.
INLET SP
IN OF WTR
FAN
HP
CAPACITY
MBH
GPM
MAX WPD
FT OF WTR
MAX APD
IN OF WTR
CONTROL PANEL
ACCESS
REMARKS
MAX
MIN
FT -1-01
6
345
140
050
1/10
---
---
---
---
LEFT
DUAL FANS
F7-1-02
16
3205
1285
0.50
(2)1/2
33.3
3.30
2
.12
LEFT
DUAL FANS
F7-1-03
10
1270
510
050
1/3
---
---
---
---
LEFT
13.6
11-1-04
12
1830
735
0.50
1/3
29.6
3.00
.1
.02
LEFT
1,405
FT -1-05
12
1740
695
0.50
3/4
28.1
2.80
.2
.08
RIGHT
13.0
FT -1-06
6
530
215
0.50
1/10
8.6
0.90
.1
0.02
RIGHT
13.5
FT -1-07
NOT USED
---
360
0.50
1/4
14 3
150
---
---
---
900
7-1-08
8
900
360
0.50
1/4
14 6
1 40
.1
02
LEFT
16.0
7-1-09
10
1310
525
050
1/3
21.2
2.10
1
01
RIGHT
12.2
7-1-10
10
1250
500
050
1/3
20.3
2.00
1
06
RIGHT
450
FT -1-11
12
1635
655
0 50
3/4
26.5
2.6
2
08
LEFT
I
FT -1-12
6
275
110
0 50
1/10
4.5
0.5
1
01
LEFT
j 0
17-1-13
10
1360
545
0 50
1/3
22.0
2.20
2
07
LEFT
1,310
FT -1-14
16
2310
925
0 50
(2)1/2
37.4
3.75
2
15
LEFT
DUAL FANS
F7-1-15
12
1620
650
0 75
3/4
26.2
2.6
2
23
LEFT
7.5
11-1-16
8
780
315
0 75
1/4
12 6
1.2
1
06
LEFT
1,310
11-1-17
12
1840
735
0.50
3/4
29.8
3.00
1
06
LEFT
10.5
F1-1-18
16
2810
1125
0.50
(2)1/2
45.5
4.50
2
.21
LEFT
DUAL FANS
FT -1-19
16
2480
990
0.50
(2)1/2
40.2
4.00
2
12
LEFT
DUAL FANS
FT -1-20
16
2480
990
0.50
(2)1/2
40.2
4.00
.2
12
LEFT
DUAL FANS
F7-1-21
16
2810
1125
0.50
(2)1/2
45 5
4.50
2
.21
LEFT
DUAL FANS
F7-1-22
8
740
295
0.50
1/4
120
120
1
05
LEFT
37,390
FT -1-23
6
510
205
0.50
1/10
8.3
0.80
1
03
LEFT
16 3
1046
(7)24/36, (1)12/12
SA -16
08
• •
2
:4
4
5
4
R -
�.
-1- 5
8
908
3.0
0.50
1/4
146
140
1
E2
LEFT
NOTE #6
- -0
500
5
9
I I
4
1 .
.
..1
8.0
23.0
17 0
FT -1-27
12
1845
740
0.50
3/4
29.9
3.00
2
.1
LEFT
12.5
F1-1-28
10
1230
490
0 50
1/3
19.9
2.00
1
14
LEFT
42,155
FT -1-29
10
1230
490
0.50
1/3
19.9
2.00
1
14
LEFT
16.0
1 F
•
:3
3
•.:
900
-
-
5
05
--
13.5
>FT-1-31
6
450
90
050
1/10
7.3
0.8
1
03
RIGHT
NOTES #4,5,6,7
FT -1-32
10
1200
490
0.50
1/3
19.9
2.00
1
14
LEFT
NOTES #4,5,6,7
I
(1)24/24
:3
•
. .
1,405
24/18
...
5
•
-
•L
FT -2-02
12
1575
630
0 50
3/4
12.8
1.30
3
08
LEFT
1,405
FT -2-03
16
3180
1270
0 50
(2)1/2
25.8
2 60
2
22
LEFT
DUAL FANS
FT -2-04
6
530
210
050
1/10
8.6
0.9
1
03
RIGHT
FT -2-05
16
3180
1270
0 50
(2)1/2
25.8
2 60
2
22
LEFT
DUAL FANS
FT -2-06
12
1590
635
0 50
3/4
25.8
2 60
2
08
LEFT
FT -2-07
12
1575
630
0 50
3/4
25.8
2 60
3
08
LEFT
FT -2-08
16
3180
1270
0 50
(2)1/2
51.5
5.00
2
22
LEFT
DUAL FANS
FT -2-09
16
3180
1270
0 50
(2)1/2
51.5
5.00
2
22
LEFT
DUAL FANS
7-2-10
16
3180
1270
0 50
(2)1/2
51.5
5.00
2
22
LEFT
DUAL FANS
FT -2-11
12
1575
630
0 50
3/4
25.5
2 50
3
08
LEFT
FT -2-12
16
3180
1270
0 50
(2)1/2
51.5
5.00
2
22
LEFT
DUAL FANS
FT -2-13
16
3180
1270
0.50
(2)1/2
51.5
5.00
2
22
LEFT
DUAL FANS
F7-2-14
10
1380
550
0.50
1/3
22 4
2.20
.1
16
LEFT
FT -2-15
10
1380
550
0.50
1/3
22 4
2.20
.1
.16
LEFT
F7-2-16
16
2865
1145
0 50
(2)1/2
464
4 60
2
12
LEFT
DUAL FANS
FT -2-17
10
1420
570
0.50
1/3
230
230
1
17
RIGHT
FT -2-18
14
2840
1135
0 50
1/3
46 0
4 60
2
22
RIGHT
FT -2-19
14
2430
970
0 50
(2)1/3
39 4
4 00
2
16
LEFT
DUAL FANS
FT -2-20
14
2840
1135
0 50
(2)1/3
46 0
4 60
2
22
LEFT
DUAL FANS
FT -2-21
14
2430
970
0 50
(2)1/3
39 4
4 00
2
16
LEFT
DUAL FANS
FT -2-22
14
2840
1135
0 50
(2)1/3
46 0
4 60
2
22
LEFT
DUAL FANS
FT -2-23
14
2430
970
0 50
(2)1/3
39 4
4 00
2
16
LEFT
DUAL FANS
FT -2-24 •
14
2840
1135
050
(2)1/3
46.0
460
2
22
LEFT
DUAL FANS
F7-2-25
14
2430
970
0.50
(2)1/3
39 4
4 00
2
16
LEFT
DUAL FANS
FT -2-26
14
2840
1135
0 50
(2)1/3
46 0
4 60
2
22
LEFT
DUAL FANS
11-2-27
14
2070
830
050
(2)1/3
335
330
2
12
LEFT
DUAL FANS
F1-2-28
14
2130
850
0 50
(2)1/3
34 5
3 50
2
13
RIGHT
DUAL FANS
11-2-29
10
1380
550
0 50
1/3
22 3
220
1
16
LEFT
F1-2-30
12
1610
645
0 50
1/4
26.1
2 60
2
09
RIGHT
FT -2-31
16
2840
1135
0 50
(2)1/2
46 0
4 60
2
22
LEFT
DUAL FANS
FT -2-32
12
1610
645
0 50
1/4
26.1
2 60
2
09
LEFT
FT -2-33
14
2130
850
0 50
(2)1/3
34.5
3.50
2
13
LEFT
DUAL FANS
FT -2-34
14
2070
830
0 50
(2)1/3
33.5
3.30
2
.12
LEFT
DUAL FANS
FT -2-35
10
1380
550
050
1/3
22.4
2.20
1
.16
LEFT
FT -2-39
8
880
" 350
0 50
1/4
14.3
1 40
1
.07
RIGHT
VCC-2-40
12/12
1600
180
050
.5
TITUS DESV-3000
FT -2-41
8
900
360
050
1/4
14.6
150
1
.08
RIGHT
FT -2-42
8
780
310
0 50
1/4
12 6
1 30
1
.06
RIGHT
FT -2-43
14
2320
930
0 50
(2)1/3
37 6
3 70
2
.15
LEFT
DUAL FANS
NOTE:
1. CONTROL PANEL ACCESS LOCATION IS BASED ON FACING OUTLET OF FAN TER
2. FAN POWERED VAV BOXES WERE SIZED BASED ON TEMPMASTER, MODEL HVF
3. SOUND NOISE CRITERIA (NC) IS BASED ON ARI STANDARD 880-89.
4
77V 1PH 6
I.
5. FAN POW ED V BO ES W RE SI ED B SED AN TITUS, MODEL DTFS.
6. BALANCE AIRFLOW AT TERMINAL UNIT TO VALUE INDICATED IN SCHEDULE.
7. REFER TO EXISTIN CONTROL SEQUENCE ON SHE M330.
TERMINAL UNITS
EQUIPMENT
tTAG
,
INLET SIZE
IN.
SUPPLY AIR CFM
REQ'D MAX.
INLET SP
IN OF WTR
FAN
HP
CAPACITY
MBH
GPM
MAX WPD
FT OF WTR
MAX APD
IN OF WTR
CONTROL PANEL
ACCESS
REMARKS
MAX
MIN
FT -2-44
14
2740
1095
0.50
(2)1/3
44.4
4.50
2
.2
LEFT
DUAL FANS
FT -2-45
12
2055
820
0.50
3/4
33.3
3.30
2
.12
LEFT
13.0
FT -2-46
8
780
310
0.50
1/10
12 6
1 20
1
.06
RIGHT
13.6
FT -2-47
6
430
170
0.50
1/10
7.0
070
1
.02
RIGHT
1,405
FT -2-48
8
610
245
0.50
1/4
99
100
1
.04
RIGHT
13.0
FT -2-49
6
195
80
0.50
1/10
32
0 60
1
.01
RIGHT
13.5
FT -2-50
8
900
360
0.50
1/4
14 3
150
1
.08
LEFT
900
FT -2-51
8
695
280
0.50
1/4
113
120
.1
.05
LEFT
16.0
FT -2-52
6
450
180
0.50
1/10
7 3
0 70
1
.02
RIGHT
12.2
FT -2-53
6
430
170
0.50
1/10
7.0
0 70
1
.02
RIGHT
450
FT -2-54
8
610
245
0.50
1/4
9 9
1.00
1
.04
LEFT
I
FT -2-55
6
530
210
0.50
1/10
8 6
0.80
1
.03
LEFT
j 0
FT -2-56
6
245
100
0.50
1/10
4 0
0.60
1
.02
LEFT
1,310
FT -2-57
6
540
215
0.50
1/10
8.7
090
1
.03
RIGHT
130
FT -2-58
8
670
270
0.50
1/4
10.9
100
1
.05
RIGHT
7.5
FT -2-59
6
270
110
0.50
1/10
4.4
060
1
.1
RIGHT
1,310
FT -2-60
8
615
245
0.50
1/4
100
100
1
.03
RIGHT
10.5
FT -2-61
6
450
180
0.50
1/10
7 3
0 70
1
.02
RIGHT
7.5
FT -2-62
6
305
125
0.50
1/10
4 9
0 60
1
.03
RIGHT
I
FT -2-63
8
670
270
0.50
1/4
109
100
1
.05
RIGHT
10.5
FT -2-64
6
575
230
0.50
1/10
93
100
1
.01
LEFT
I
FT -2-65
12
1590
635
0.50
3/4
25.8
2 60
2
.08
LEFT
37,390
NOTE:
1. CONTROL PANEL ACCESS LOCATION IS BASED ON FACING OUTLET OF FAN TERMINAL BOX.
2. FAN POWERED VAV BOXES WERE SIZED BASED ON TEMPMASTER, MODEL HVFS.
3. SOUND NOISE CRITERIA (NC) IS BASED ON ARI STANDARD 880-89.
4. 277V / 1PH / 60HZ
REVIEWED FOR
ODE COMPLIANCE
APPROVED
NOV 2 7 2013
CiZy of Tukwila
ILDING DIVISION
SOUND ATTENUATOR SCHEDULE
MARK
NO
SERVICE
BASIS OF DESIGN
MANUFACTOR
& MODEL NUMBER
CFM
SIZE
IN.
WXH
ATTENUATOR
MIN. DYNAMIC INSERTION LOSS
W-1-01
REMARKS
MAX .VEL.
FPM
LENGTH
FT.
MAX.P.D.
IN. WG.
63
125
250
500
1K
2K
4K
BK
WEIGHT
LBS
SA -'1
MODEL TEST FACILITY, RETURN
IAC-5LFMs
1,475
42/12
450
5
.05
10.6
13.6
24.6
29.6
28.0
16.5
130
13.0
102
(1)42/12
SA -2
MODEL TEST FACILITY, RETURN
IAC-5LFMs
1,475
42/12
450
5
.05
10.6
13.6
24.6
29.6
28.0
16.5
130
13.0
102
(1)42/12
SA -3
MODEL TEST FACILITY, SUPPLY
IAC-5LFMs
1,405
24/18
500
5
.05
10.5
13.5
24.5
29.5
28.0
16.5
13.0
13.0
87
(1)24/18
SA24
MODEL TEST FACILITY, SUPPLY
IAC-5LFMs
1,405
24/18
500
5
.05
10.5
13.5
24.5
29.5
28.0
16.5
13.0
13.0
87
(1)24/18
SA -5
SOUND DEMO CRITICAL LISTENING, SUPPLY
IAC-5LFs
900
36/36
200
5
.05
14 6
19.8
32.6
37.6
39.8
27.0
21.2
16.0
150
(1)24/24, (1)12/12
SA -6
SOUND DEMO CRITICAL LISTENING, SUPPLY
IAC-3LFs
900
36/36
200
3
.05
8.4
12.2
23.0
26.2
25.2
19.6
16.2
13.2
93
(1)24/24, (1)12/12
SA -;7
SOUND DEMO CRITICAL LISTENING, RETURN
IAC-3LFs
450
24/24
200
3
.05
8.4
12.2
23.0
26.2
25.2
19.6
16.2
13.2
93
(1)24/24, (1)12/12
SA=8
SOUND DEMO CRITICAL LISTENING, RETURN
IAC-3LFs
450
24/24
200
3
.05
8.4
12.2
23.0
26.2
25.2
19.6
162
13.2
93
(1)24/24, (1)12/12
-SA-9
SOUND DEMO CONTROL ROOM, SUPPLY
IAC-5LFMs
1,310
24/24
400
5
.05
10.6
13.6
24.6
29.6
28.0
16.4
130
130
102
(1)24/24
SA -10
SOUND DEMO CONTROL ROOM, RETURN
IAC-3LFMs
1,310
24/24
500
3
05
5.0
7.5
16.0
19.0
17.0
12.5
105
105
89
(1)24/24
SA -11
SOUND DEMO CONTROL ROOM, RETURN
IAC-3LFMs
1,310
24/24
500
3
05
5.0
7.5
16.0
19.0
17.0
12.5
105
10.5
89
(1)24/24
SA -12
DYNAMIC CALIBRATION AREA, SUPPLY
IAC-3LFMs
780
24/18
500
3
05
5.0
7.5
16.0
19.0
17.0
12.5
10 5
10.5
52
(1)24/18
SA -13
DYNAMIC CALIBRATION AREA, RETURN
IAC-3LFMs
780
24/24
500
3
05
5.0
7.5
16.0
19.0
17.0
12.5
10 5
10.5
89
(1)24/24
SA -14
DYNAMIC CALIBRATION AREA, RETURN
IAC-3LFMs
780
12/18
500
3
05
5.0
7.5
16.0
19.0
17.0
12.5
10 5
10 5
34
(1)12/18
SA -15
AHU-1, RETURN
IAC-5LFs
37,390
180/36
850
5
44
13.3
19.3
31.3
36.3
39.3
27.3
22 3
16 3
1046
(7)24/36, (1)12/12
SA -16
AHU-2, RETURN
IAC-5LFs
33,510
180/36
750
5
34
13.5
19.5
31.5
36.5
39.5
27.5
22.5
165
1046
(7)24/36, (1)12/12
SA -17
AHU-3, RETURN
IAC-5LFs
18,335
180/36
500
5
0.10
14.0
20.0
32.0
37.0
40.0
28.0
23.0
17 0
1046
(7)24/36, (1)12/12
SA -18
AHU-4, SUPPLY
IAC-3LFs
53,500
144/108
500
3
15
9.0
12.5
23.0
26.5
25.5
20.5
16.5
13 5
1224
(9)48/36 3 ROWS HIGH
5A-19
AHU-4, RETURN
IAC-5LFs
42,155
180/36
950
5
55
13.1
19.1
31.1
36.1
39.1
27.0
22.0
16.0
1046
(7)24/36, (1)12/12
SA -20
7-1-08, RETURN
IAC-5LFM
900
24/24
500
5
05
105
13.5
24.5
29.5
28.0
16.5
13.0
130
87
(1)24/24
SA -21
FT -1-09, RETURN
IAC-5LFM
1,310
24/24
500
5
05
105
13.5
24.5
29.5
28.0
16.5
13.0
13.0
87
(1)24/24
SA -22
FT -1-18, RETURN
IAC-5LFM
1,405
24/18
500
5
05
105
13.5
24.5
29.5
28.0
16.5
13.0
13.0
87
(1)24/18
SA -23
MODEL TEST FACILITY, SUPPLY
IAC -513
1,405
24/18
5
20
SA -24
MODEL TEST FACILITY, SUPPLY
IAC-5LS
1,405
24/18
5
20
SA -25
MODEL TEST FACILITY, RETURN
IAC -513
2,245
48/18
5
.10
SA -26
CONFERENCE ROOM, SUPPLY
44/18
nick'
TERMINAL UNITS
EQUIPMENT
TAG
INLET
SIZE IN.
SUPPLY AIR CFM
REVD MAX.
INLET SP
IN. OF WATER
REMARKS
MAX
MIN
W-1-01
8
700
140
0.49
W-1-02
7
550
110
0.52
W-1-03
7
500
100
0.45
W-1-04
10
1070
214
0.48
W-1-05
14
1400
280
0.50
W-1-06
8
700
140
0.47
W-1-07
14
2260
452
0.50
W -I-08
10
1620
324
0.50
W-1-09
10
1230
246
0.50
W-1-10
10
1230
246
0.50
A
.•
-.
>W-1.-12
24x16
5700
1140
0.50
NOTES #3,4,5
,e
A
0
X
0
. NDIS IT ( L IS ED A
3. VAV BOXES WERE SIZED BASED ON TITUS, MODEL D .
4. BALANCE AIRFLOW AT TERMINAL UNIT TO VALUE INDICATED IN SCHEDULE.
5. REFER TO EXISTING CONTROL SEQUENCE ON SHEET M330.
'O3
DAR
S, EXCEPT WHERE NOTED
880-2011.
EIVED
CITY OF TUKWI
NOV .1 2 2013
PERMIT C ' TE
CONSTRUCTION NOTES
1� PROVIDE NEW EQUIPMENT AS SCHEDULED.
90% SUBMITTAL
ISSUED FOR PERMIT
1\
'.Illll
Wood
Harbinger
STM
RECORD DRAWING J/972197-00
A
CDC RELOCATION - WIRE SHOP RELOCATION Jj19760
BY
HGI/SHS
WH
APPROVED
DATE
SYN
BENSON
RI
APPROVED
DATE
11.12.99
481
10.22.13
ACCEPTABILITY
THIS DESIGN MND/OR
SPECIFICATION IS APPROVED
APPROVED BY DEPT. DATE
DRAM
R. TNESS
MITREED
S. FRANKLIN
DATE
11.12.97
3.30.98
EQUIPMENT SCHEDULE
CURRENT WILSON
J#19760
SYMBOL
A
DATE
10.22.13
'L GRNLCR
G. FRANEK
NECKED
11.12.97
6.3.98
APPROVED
L COSTELLO
6.3.98
APPROVED
R. 4CNIESH
6.3.98
TITLE
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
MECHANICAL MASTER PLANT 2
sNEtT
M1B
JOB NO. 972197-00
COMP NO.
DWG N0.
2-81-M1B Page 5 of 27
SUPPLY DIFFUSERS, RETURN, EXHAUST, AND
TRANSFER GRILLES NOISE CRITERIA SCHEDULE
ROOM NAME / ROOM NUMBER
CRIITTERIA
(NC)
MODEL TEST FACILITY / 13C3
25
MODEL BUILDUP STAGING / 1181
35 TO 40
SOUND DEMO CONTROL ROOM / 14G4
25
ARF FACILITY / 11G5
35
OPEN OFFICES AREA / 21C1
35
WAVE GUIDE FACILITY / 12G5
35
WAVE GUIDE CONTROL ROOM / 11J5
35
ELECTRICAL SHOP / 12G3
35 TO 40
MTC CONTROL ROOM / 11G7
35
MTC FLOW ROOM / 11H7
35
MTC Z -TUBE ROOM / 12H7
35
HI -TEMP TEST / 12G7
35 TO 40
MODEL LSAF FACILITY / 11F7
35 TO 40
FACILITY COMPONENTS AND TEST PARTS / 13G5
35 TO 40
DATA ROOM / 14E5
35
LAB / 11G4
35
TRANSDUCER & RECORDER CALIBRATION FACILITY / 13F3
30
CONFERENCE ROOM / 21D5
30 TO 35
PRIVATE OFFICES, WORK ROOMS, VISIBILITY ROOMS
30 TO 35
INSTRUMENTATION VAN STAGING AREA / 11F3
40 TO 45
S- " N • D " 1
' L TA •
WIRE SHOP /•11C3
40 TO 45
F . T " .1P 3:.
B .1
TRANSDUCER RECORDING CALIBRATION / 1284
30 TO 35
DINING AREA / 12E7
35 TO 40
CORRIDORS
38 TO 42
DYNAMIC INSTRUMENTATION LAB / 21KJH5
35 TO 40
DYNAMIC CALIBRATION AREA / 21G5
35 TO 40
DYNAMIC INSTRUMENTATION LAB / 21H5
38 TO 42
PLUMBING FIXTURE SCHEDULE
SYMBOL
DESCRIPTION
CONNECTION SIZE
SAN
V
CW
HW
P-1
HANDICAPPED WATER CLOSET
4"
2'
1"
--
P-2
WATER CLOSET
4"
2"
1"
--
P-3
URINAL
2"
1-1/2"
3/4"
--
P-3(H)
HANDICAPPED URINAL
2"
1-1/2"
3/4"
--
P-4
LAVATORY
1-1/2"
1-1/2"
1/2"
1/2"
P-5
WASHFOUNTAIN
2"
1-1/2"
1/2"
1/2"
P-6
SHOWER
2"
1-1/2"
1/2"
1/2"
P-7
SERVICE SINK
2"
2"
1/2"
1/2"
P-8
KITCHEN SINK
2"
2"
1/2"
1/2"
P-9
WATER CLOSET
4"
2"
3/4"
--
P-10
LAVATORY
2"
2"
1/2"
1/2"
P-11
JANITOR SINK
3"
1-1/2"
1/2"
1/2"
DF -1
DRINKING FOUNTAIN
1-1/2"
1-1/2"
1/2"
--
DF-2
DRINKING FOUNTAIN
1-1/2"
1-1/2"
1/2"
--
FD-1
FLOOR DRAIN
2"
2"
--
--
FD-2
FLOOR DRAIN
2"
2"
1/2"
--
FD-3
FLOOR DRAIN
4"
2"
1/2"
--
FS
FLOOR SINK
2"
2"
1/2"
--
TP
TRAP PRIMER
--
--
1/2"
--
EEW
EMERGENCY EYEWASH
1-1/4"
1-1/2"
1/2"
--
INTAKE AIR PENTHOUSE SCHEDULE
MARK NO.
LOCATION
SERVICE
DIM. INCH
CFM
MANUFACTURER/MODEL
REMARKS
LENGTH
WIDTH
HEIGHT
INSTALL WITHIN EXISTING EXHAUST DUCT
FSD-2
WIRE SHOP
48/36
RUSKIN, MODEL CD 60
NOT INSTALLED
FSD-3
N.E. CORRIDOR
10/10
PH -1
ROOF E/5
AHU-5&6
72
48
40
14,370
RUSKIN
NOTE 1
NOTE: 1 PROVIDE ACCESS DOOR(S) ON EAST SIDE FOR ACCESS TO MOTOR OPERATED DAMPERS LOCATED AT ROOF.
FIRE / SMOKE DAMPERS
MARK NO.
SERVICE
SIZE
MANUFACTURER / MODEL
REMARKS
WXH(IN)
FSD-1
N.W. CORRIDOR
12/12
RUSKIN, MODEL FSD 60
INSTALL WITHIN EXISTING EXHAUST DUCT
FSD-2
WIRE SHOP
48/36
RUSKIN, MODEL CD 60
NOT INSTALLED
FSD-3
N.E. CORRIDOR
10/10
RUSKIN, MODEL FSD-60
INSTALL WITHIN NEW RA DUCT
ATTACHED TO EXISTING OSA DUCT
FSD-4
LOBBY
24/24
RUSKIN, MODEL FSD-60
INSTALL WITHIN NEW RA DUCT
ATTACHED TO EXISTING OSA DUCT
FSD-5
JANITORS ROOM
12/12
RUSKIN, MODEL FSD-60
COMPUTER ROOM
FSD-7
MAIN CORRIDOR
16/16
RUSKIN, MODEL FSD-60
11
FSD-7A
MAIN CORRIDOR
12/12
RUSKIN, MODEL FSD-60
55
FSD-8
W. CORRIDOR
14/14
RUSKIN, MODEL FSD-60
LEIBERT, MODEL BUO67A
FSD-9
ELEVATOR MACHINE RM
12/12
RUSKIN, MODEL FSD-60
-
FSD-11
WOMEN'S LOCKER RM
16/16
RUSKIN, MODEL FSD-60
-
FSD-12
MEN'S LOCKER ROOM
16/16
RUSKIN, MODEL FSD-60
3
FSD-13
WOMEN'S TOILET
12/24
RUSKIN, MODEL FSD-60
DX -2
FSD-14
MEN'S TOILET
12/24
RUSKIN, MODEL FSD-60
0.5
FSD-19
N.E. CORRIDOR
18/18
RUSKIN, MODEL FSD-60
15.0
FSD-20
N.E. CORRIDOR
16/10
RUSKIN, MODEL FSD-60
26 7
FSD-21
N.E. CORRIDOR
10/8
RUSKIN, MODEL FSD-60
ROOF
FSD-22
JANITOR'S ROOM
22/22
RUSKIN, MODEL FSD-60
-
FSD-23
INST ST AREA
36/16
RUSKIN, MODEL FSD-60
277
FSD-24
INST ST AREA
20/18
RUSKIN, MODEL FSD-60
SPLIT SYSTEM. HPR
COND. UNIT W/ PROPOP FAN FAN
FSD-25
INST ST AREA
36/16
RUSKIN, MODEL FSD-60
FSD-26
INST ST AREA
52/14
RUSKIN, MODEL FSD-60
FSD-27
INST ST AREA
10/10
RUSKIN, MODEL FSD-60
FSD-28
INST ST AREA
26/26
RUSKIN, MODEL FSD-60
CONTROL DAMPERS
MARK NO.
SERVICE
SIZE
MANUFACTURER / MODEL
REMARKS
WXH(IN)
CD -EF -5
WIRE SHOP
30/20
RUSKIN, MODEL CD 60
INSTALL WITHIN EXISTING EXHAUST DUCT
CD-AHU-6-OSA
WIRE SHOP
48/36
RUSKIN, MODEL CD 60
INSTALL WITHIN EXISTING OSA DUCT
CD-AHU-6-RA-1
WIRE SHOP
36/36
RUSKIN, MODEL CD 60
INSTALL WITHIN NEW RA DUCT
ATTACHED TO EXISTING OSA DUCT
CD-AHU-6-RA-2
WIRE SHOP
36/36
RUSKIN, MODEL CD 60
INSTALL WITHIN NEW RA DUCT
ATTACHED TO EXISTING OSA DUCT
NOTE: PROVIDE 24 VOLT ACTUATOR
REFRIGERATION/CONDENSER UNITS
MARK NO.
SERVICE
LOCATION
FAN
HUMIDIFIER
FILTERS
ENTERING AIR
LEAVING AIR
ELECTRICAL
MANUFACTURER/MODEL
REMARKS
CFM
HP
S.P.
IN E..C.
LB/HR
LB HR
% EFFICIENCY
T DEG F
% RH
TOTAL
MB H
DEG -F
VOLTS
PHASE
Hz
FLA
DX -1
COMPUTER ROOM
COMP
COL D.5 E.5UTER J200M
2800
2.0
0.5
11
30
72
50
58.0
55
480
3
60
28.9
LEIBERT, MODEL BUO67A
ELECTRIC REHEAT
CND -1
SERVES DX -1
ROOF
-
0.5
-
-
-
-
-
65.0
-
480
3
60
13,4
LEIBERT, MODEL PFC067A
SPLIT SYSTEM. HORIZONTAL
COND. UNIT W/ PROP FAN
DX -2
DATA VAULT
DATA VAULT
750
0.2
0.5
2.5
30
72
50
15.0
55
277
1
60
26 7
LEIBERT, MODEL MMD18E
ELECTRIC REHEAT
CND -2
SERVES DX -2
ROOF
-
0.2
-
-
-
-
-
19.5
-
277
1
60
10,7
LEIBERT, MODEL PFCO20A
SPLIT SYSTEM. HPR
COND. UNIT W/ PROPOP FAN FAN
FILET ;
CONDENSER UNITS DESIGN: SUMMER 95'F/ WINTER 0'F
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
CONSTRUCTION NOTES
PROVIDE NEW EQUIPMENT AS SCHEDULED.
90% SUBMITTAL
ISSUED FOR PERMIT
RECEIVED
CITY OF TUKWILA
NOV 1 '2 2013
PERMIT CENTER
Wood
Harbinger
4111\1\11
30o9 urth Ane NE.
Sole wb
BoII o WA 9Boo4
425638.6ODo
r00ERTNNTgeT.mm
SYM
A
RECORD DRAWING Jj972197-00
CX RELOCATION - WIRE SHOP RELOCATION J+19760
BY
HGI/SHS
WH
APPRCRED
DATE
SIA
BY
APPRO+ED
DATE
11.12.99
N81
10.22.13
BOE/A/G®
ACCEPTABILITY
1H6 DESIGN AND/OR
SPECIFICATION 6 APPROVED
APPROVED BY DEPT. DATE
DRAWN
R.R. TOPNESS
MITRED
S. FRANKUN
DATE
11.12.97
3.30.98
SUEMTLE
EQUIPMENT SCHEDULE
CURRENT REVISION
419760
SYMBOL
A
DATE
10.22.13
•1:NGINLLN
G. FRANEK
CHECKED
G. SPRAGUE
11.12.97
6.3.98
APPROVED
L.. COSTELLO
6.3.98
APPROVED
R. 4CNIESH
6.3.98
MECHANICAL MASTER
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
PLANT 2
tEET MIC
Jos Na
972197-00
COMP NO.
DWG NO.
2-81-M1C Page of 27
S
GENERAL NOTES
1 CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO
FABRICATION AND INSTALLATION. FIELD VERIFY DIMENSIONS TO
EXISTING BUILDINGS. OBTAIN APPROVAL FOR PROPOSED FIELD
CHANGES TO THE WORK FROM THE ENGINEER OR THE OWNERS
REPRESENTATIVE BEFORE THE FABRICATION AND WORK IS
INSTALLED.
2 ALL EQUIPMENT AND MATERIALS SHALL BE NEW. REUSE OF
EQUIPMENT OR MATERIALS IS NOT PERMITTED.
3 THE CONSTRUCTION AREA SHALL BE MAINTAINED IN A CLEAN
AND ORDERLY MANNER AT ALL TIMES.
4. EQUIPMENT OR MATERIAL DAMAGED DURING CONSTRUCTION
SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO
REPLACE AT HIS COST.
5 EQUIPMENT AND MATERIALS SHALL BE STORED AT LOCATIONS
AS DIRECTED BY THE OWNER AND THE ENGINEER. PROVIDE
PROTECTION FROM PHYSICAL DAMAGE, DUST, WATER AND THE
ELEMENTS.
6. CONTRACTORS AND SUB -CONTRACTORS SHALL COORDINATE
WITH OTHER DISCIPLINES TO PREVENT INTERFERENCES AND TO
MAINTAIN SUITABLE EQUIPMENT ACCESS FOR SERVICING AND
MAINTENANCE BEFORE THE WORK IS INSTALLED.
7. THE DRAWINGS AND SPECIFICATIONS DO NOT RELIEVE THE
CONTRACTOR FROM THE RESPONSIBILITY OF PROVIDING
COMPLETE OPERABLE SYSTEMS.
8. ALL CRAFT PERSONNEL SHALL BE QUALIFIED IN THEIR FIELD OF
WORK IN ACCORDANCE WITH CODES AND CRAFT STANDARDS.
ALL WORK SHALL BE INSTALLED TO THE HIGHEST INDUSTRY
STANDARDS OF WORKMANSHIP.
FIRE PROTECTION
1. ALL FIRE PROTECTION PIPING SHALL BE INSTALLED IN ACCORDANCE
WITH SPECIFICATIONS AND LOCAL CODE REQUIREMENTS.
2 SEE DRAWINGS 2-81-M525 AND M526 FOR PIPING SUPPORTS.
3 SEE DRAWING 2 -B1 -M515 FOR DETAILS.
4 SEE PLANS FOR OTHER PERTINENT NOTES.
PLUMBING
1 ALL PLUMBING SHALL BE INSTALLED IN ACCORDANCE WITH
SPECIFICATIONS AND LOCAL PLUMBING CODE REQUIREMENTS.
2 CONTRACTOR SHALL INSTALL HIGH POINT VENTS AND LOW POINT
DRAINS AS REQUIRED TO PERMIT FULL DRAINAGE OF ALL WATER
PIPING.
3. SLOPE ALL SANITARY LINES AT 1/4" PER FOOT (MINIMUM SLOPE)
UNLESS NOTED OTHERWISE.
4 SEE CML DRAWINGS FOR UNDERGROUND PLUMBING FOR 5 FEET
AND BEYOND BUILDING FOUNDATION.
5 SEE SPECIFICATIONS FOR INSULATION OF HOT WATER (HW), HOT
WATER CIRCULATION (HWC) AND COLD WATER (CW) PIPING.
6. SEE DRAWINGS 2-81-M1O, M 1 b AND M 1 c FOR EQUIPMENT
SCHEDULES.
7. ALL OPEN ENDED PIPING SHALL BE CAPPED OFF TO PREVENT
DUST AND DEBRIS FROM ENTERING THE PIPING.
8. SEE DRAWINGS 2-81-M525 AND M526 FOR PIPING SUPPORTS.
9. SEE DRAWINGS 2-81-M513 & M514 FOR DETAILS.
►A�
1. SEE 2-81-M310 AND 2-81-M311 FOR CONTROL SEQUENCES.
2.
SCHEDULES.
2-
1b
NI 1c 0
9
3. SEE ARCHITECTURAL AND STRUCTURAL DRAWINGS
SPECIFICATIONS AND DRAWINGS FOR EQUIPMENT MOUNTING
AND ACCESS PLATFORMS.
4. SECOND FLOOR BOTTOM OF DUCTWORK SHALL NOT BE LOCATED BELOW
11'-0" ABOVE FINISHED FLOOR (AFF) UNLESS OTHERWISE NOTED.
5. SECOND FLOOR TOP OF DUCTWORK SHALL NOT BE LOCATED ABOVE
14'-0" ABOVE FINISHED FLOOR (AFF) UNLESS OTHERWISE NOTED.
6. THERMOSTAT LOCATIONS SHALL BE LOCATED AS SHOWN
ON DRAWING. MOUNT 5'-0" AFF, UNLESS NOTED OTHERWISE.
7. ALL DUCTWORK SHALL BE SUPPORTED FROM STRUCTURAL
MEMBERS ONLY
8. ALL DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH
SPECIFICATIONS, CODE AND SMACNA FOR MEDIUM AND LOW
PRESSURE SYSTEMS.
9. SEE DRAWINGS 2-81-M500 THRU M510 FOR DETAILS
AND SECTIONS.
10. DUCTWORK OPENINGS SHALL BE PROTECTED AT ALL TIMES
DURING CONSTRUCTION TO PREVENT DUST AND DEBRIS
FROM ENTERING THE DUCTWORK.
11. DUCTWORK TRANSITIONS SHALL BE CONCENTRIC UNLESS OTHERWISE
NOTED.
12. ALL DUCT DIMENSIONS ARE INSIDE, OPEN FREE AREA.
13. FOR TYPICAL HVAC SECTION, SEE SECTION A ON DRAWING
2-81-M504.
14. FOR MAIN DUCT RUNS ON FIRST FLOOR, BOTTOM OF DUCTWORK
SHALL NOT BE LOCATED BELOW 16'-0" ABOVE FINISHED FLOOR
(AFF) UNLESS OTHERWISE NOTED.
15. FOR MAIN DUCT RUNS ON FIRST FLOOR, TOP OF DUCTWORK SHALL
NOT BE LOCATED ABOVE 17-6" ABOVE FINISHED FLOOR (AFF)
UNLESS OTHERWISE NOTED.
16. ELEVATION OF TRANSFER GRILLES IN ROOMS WITHOUT A CEILING
SHALL BE 12'-0". ELEVATION OF TOP OF GRILLES IN ROOMS
WITH A CEILING SHALL BE 6" BELOW FINISHED CEILING.
17. MOUNT ALL CABINET UNIT HEATERS AT 16'-0", UNLESS
OTHERWISE NOTED.
18. SEE DRAWINGS 2-81-M322 THRU M333 FOR CONTROL P&ID'S.
HVAC PIPING
1. SEE DRAWINGS 2-81-M316 THRU M321 FOR FLOW DIAGRAMS.
2. SEE DRAWINGS 2-81-M450 THRU M501 AND 2-81-M530
FOR DETAILS.
3. SEE DRAWINGS 2-81-M1a, M 1 b AND M 1 c FOR EQUIPMENT
SCHEDULES.
4. SEE PLANS FOR OTHER PERTINENT NOTES.
5. SEE DRAWINGS 2 -B1 -M322 THRU M333 FOR CONTROL P&ID'S.
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
90% SUBMITTAL
ISSUED FOR PERMIT
RECEIVED
CITY OF TUKWILA
NOV .1 2 2013
PERMIT CENTER
Wood
Harbinger
pop uAh Ave NE.
Sub HE
EWEN. WA 98o34
a00mo
WODBuHNRPcmm
RECORD DRAWING 4972197-00
CDC RELOCATION - WIRE SHOP RELOCATION 419760
BY
HGI/SHS
WH
APPROVED
DATE
GYM
REV'BON
BY
APPROVED
DATE
11.12.99
681
10.22.13
g)LAmerAE-,Avc.
ACCEPTABILITY
THIS DESIGN AND/OR
SPECIFICATION IS APPROVED
APPROVED BY DEPT. DATE
DRAWN
S. FRANKUN
MIMEO
G. FRANEK
DATE
4.10.98
4.13.98
GENERAL NOTES
CURRENT REVISION
J(J19760
SYMBOL
A
DATE
10.22.13
tNLINELH
C. FRANEK
CHECKED
G. SPRAGUE
4.10.98
6.3.98
L 60 ELLO
6.3.98
APPROVED
R. MCNIESH
6.3.98
'MU WIRE SHOP RELOCATION TO 2-81
MECHANICAL MASTER
BUILDING 2-81
PLANT 2
GNEET M2
JOB 972197-00
HD
COUP NO.
ONG NO.
2-81-M2 Page 7 o127
41/77 /N11 7.141/1 A11
30,-0'
'TO 'INTO
20/12
120
MOD
RG 20/20
FOR CONTINUATION SEE SHEET 2-81-1M10
CORRIDOR
11103 I
30/100
80/120
1M12 M502
W3
20/12
52/140
SHIPPING AND
RECIEVINC - N16
11164
D 8/
10 C'
RG 12/12
5 CFM
RG 30/12
1770 CFM
30/100 1`0§
POC
TG 12/ 2
400 C M
260
280
FI F(' 1
,6
RG 18/10
750 CFM
80 UP TO EF -12
280 UP TO EF -06
200 UP TO EF -01
20/10 RA BELOW
20/30 UP TO EF -05
AD
140 UP
TO EF -15
E 12/12
FIELD TESL
BUILDUP - RID
11364
TG 12/12
80 W/VD
EVA) R
H. RnDM
F:
D-AHU-6-OSA
G 2/12
;JI)
100
1140
148/36 ABO
1M12 M506
1 12 M504
SG 6/6
170 CFM
1M12 M506
30/24
30/24
68/18
80
(BELOW)
SD 12/12
300 CFM
(TYP OF 3)
120
CD-AHU-6-RA-2
FOR CONTINUATION
IN THIS AREA, SEE1M12
o❑
144/20
M1M456
SG 12/6
150 CFM
TYP OF 3
62/38
L hiI , 142/24 I WIRE • ESH
1M12
0
0
0
0
SD 18/18
700 CFM
DUCTWORK
SCALE: 1/8'=l'-0'
z
8
0
moi
VESTIBULE
I 12E7 I
0
B
0
LEGEND
LEGEND
MOTORIZED DAMPER
POC = POINT OF CONNECTION
GENERAL NOTES
1. SEE SUPPLY DIFFUSER, RETURN, EXHAUST
AND TRANSFER GRILLE SCHEDULE ON
DWG 2-81-M1
PROVIDE ACCESS DOOR IN SA DUCT DOWNSTREAM
FRO r EAC. FIR MOKE DAMPER.
0
0
REVIEWED FOR
ODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
UILDING DIVISION
`0
90% SUBMITTAL
ISSUED FOR PERMIT
REFERENCE DRAWINGSWI
M310, M311, 27 M330 M1M456, M506
CONSTRUCTION NOTES
RELOCATE EXISTING TEMPERATURE SENSOR AS
SHOWN.
PROVIDE NEW ROUND DIFFUSER. PROVIDE NEW
RIGID ROUND DUCT TO EXTEND FROM EXISTING
DUCT AND ELBOW DOWN TO NEW DIFFUSER. NEW
DUCT TO MATCH SIZE OF EXISTING.
PROVIDE NEW MOTORIZED DAMPER IN EXISTING
DUCT AT THIS LOCATION
PROVIDE NEW RETURN GRILLE ON EXISTING DUCT.
MOUNT GRILLE ON FACE OF SOFFIT. PATCH AND
REPAIR SOFFIT PER ARCHITECTURAL.
STEAM CLEAN INTERIOR OF FORMER GREASE DUCT
AS PART OF THIS WORK.
PROVIDE NEW FAN COIL AND ASSOCIATED
DUCTWORK. REFER TO SCHEDULE ON SHEET MTA
FOR ADDITIONAL INFORMATION.
PROVIDE NEW SECTION OF DUCT WHERE VOLUME
DAMPER WAS REMOVED DUCT SIZE TO MATCH
EXISTING.
PROVIDE NEW FAN TERMINAL UNIT.
0
0
0
0
0
0
0
1M13
2-81 BUILDING
KEY PIRECEIV4D
e1`ry OF TURWILA
NOV .1 2 2013
PERMIT CENTER
Wood
Harbinger
mO9 lath Aare NE
&Iztoo
O.8.ate WA 98004
aoemnrNnger.am
RECORD DRAWING
4972197-00
HGI/SHS
MODIFY 2-81 CAFETERIA
LAPTOP HOTELING
10/13884-50
CDC RELOCATION - WIRE SHOP RELOCATION
J119760
11 12.99
7/24/00
1.12.12
10.22 13
el__ArwArc.
ACCEPTABILITY
1H5 DESIGN AND/OR
SPECIFICATION 5 APPROVED
APPROVED BY DEPT. DATE
K. [Won
A. P'MELTDR
INWNEEN
G. FRANEK
CHECKED
C. SPRAGUE
1.12.98
1.1298
m
DUCTWORK
4119760
10.22.13
WIRE SHOP RELOCATION TO 2-81
APPROVED
L COSTELLO
APPROVED
R. MCNIESH
6.3.98
BUILDING 2-81
MECHANICAL MASTER COL. A -F/3-8
PLANT 2
DWG NO.
972197-00
2-81-1M12 Page 8of27
U
(B)
30'-0"
U U CU U
30'-0" 30.-0"
a
3/4" FT
4)m—iL-�
0
1" FUTURE
CONNECTION
MATCHLINE SEE SHEET 1M60
1 1/2" FUTURE
CONNECTION
HWS—
HWR
BUTTERFLY VALVE
IN RISER
1'
1
V U
v v
3"x2"
III_I
III I 061
0o
c
SEE DETAIL
1M62 M1M456
1=1 f —11 I
I I I III I
I I I III I
I jjI I I
col
AH
05
3/4"
C C
�\,� C -II
-IoI
3/4"
3/4"
ti
4"x2"
3"x2"
.11. 1 1 1 1
3/4"
■
I 11
161 T
(TYP) ALL FAN
t 1-227 ERMINAL UNITS
HVAC - PIPING
SCALE: 1/8"=1'-0"
101
1 1/2" FUTU
CONNECTION
2" CHWR
2
RE
MATCHLINE SEE SHEET
0
U
GENERAL NOTES
1 SEE COIL CONNECTION DETAILS ON SHEET M530.
2. ALL HVAC PIPING SHALL BE A MINIMUM OF
18'-0" ABOVE FINISHED FLOOR.
3. SEE DRAWING 2-81—M525, M526 FOR PIPE
HANGER DETAILS.
® SEE 1M62
FOR PIPE
M526 1M62
PENETRATION
M526
DETAILS
5. SEE DRAWING 2-81—M319. M320, M321 FOR SYSTEM
PIPING DIAGRAM.
6
MOUNT UNIT HEATER AS HIGH AS POSSIBLE.
REFERENCE DRAWINGS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
90% SUBMITTAL
ISSUED FOR PERMIT
CONSTRUCTION NOTES
RtetiVE D
C ILA
NOV 1 2 2013
PERMIT CENTER
VIII
iillNl��
Wood
Harbinger
WON urth Nle NE.
Suite am
Bellevue WA98004
QSkU3a000
rDDmdrmntecmm
SYM
A
REVISION
RECORD DRAWING 4972197-00
CDC RELOCATION - WIRE SHOP RELOCATION 4119760
NY
601/SHS
WH
APPROVED
DATE
SYM
REVISION
et
APPROVED
DATE
11.12 99
10.22.13
gLIM7E,AW
ACCEPTABILITY
THIS DESIGN AND/OR
SPELTFIGTION IS APPROVED
APPROVED 6Y DEPT. DATE
-DRAWN
S. FRANKLIN
A. NAPIER
12
T1
12.8.97
3.18.98
SUBTITLE
HVAC PIPING
CURRENT REVISION
4119760
mem
A
DATE
10.22.13
1ENWNEER
E. YOOSEFIAN
CHECKED
G. SPRAGUE
12.8.97
6.3.98
APPROVED
L. COSTELLO
6.3.98
APPROVED
R. MCNIESH
6.3.98
TITLE
MECHANICAL MASTER
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
COL. A—F/3-8 PLANT 2
sHET 1 M62
JOB No. 972197-00
COMP NO.
DWG NO.
2-81-1M62 Page 9of27
D
( N2
C)
3/4"
HYDRAULIC UNIT
SEE DETAIL l
1M1101M513
3/4"
MECH. BUILDUP
3/4" STAGIIG AREA - S10
1 1/2"V ,I 1151
P-7 EEW-1
DF -1
1/2
A
A
�1182>
- L- _
VENT UP
TO ROOF
2"FD-2
FCO
3/4"
1-3 •
BOP 14'-0"
3/4*CW
A
L
y_9)3P 19'-0
A
3/4
ELECTRICAL
SHOP - S9
1 1163 1 3/4"CW -"
\1
767
W4 ;
II 1/21/1
CW
A
3/4"
a
„,-1/2”
3/4"
L3
A
1/2"
E
3/4
3/4"
IC. -
M110
3 4"
1/2
M51
1/2"
G
t
L -2E1
2x1
CO, iDCR
I 1 E II
J
MODEL TEST
FACILITY - S5
1303 1
i4C3
`3/4"
1303
"O""I OR
1/21
a
MATCHLINE SEE SHEET 2-81-1M111
1 1/4" 3/4"
3
1 1/2"
3
vAIMIA•AIIMAAA''.11111W'AIMINAAIIIRINIA:I=PA:. �� 0
REVIEWED FOR
CODE
PR VED CE
AP
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
PLUMBING
SCALE: 1/8"=1'-0"
O
1/2"
2 1/2"
1 1/4"
1 1/4"
2 1/2"
LEGEND
GENERAL NOTES
1 > POINT OF USE WATER HEATER MOUNT ON METAL SHELF
LOCATED 6'-6" MINIMUM ABOVE FLOOR. LOCATION AS
APPROVED BY BOEING REP PROVIDE SEISMIC RESTRAINT
STRAP ANCHORED TO WALL. PROVIDE SHELF SUPPORT
BRACKETS CONSTRUCTED FOR 100 POUND STATIC LOAD.
PROVIDE SHUT OFF VALVE IN CW LINE TO HEATER.
2. FOR TYPICAL INSTALLATION OF AIR OUTLETS AND BACK-
FLOW PREVENTOR SEE TYPICAL PLUMBING DETAIL SHEET
M513.
3 > INSTALL WATER FILTER FOR DRINKING FOUNTAIN DF -1.
REFERENCE DRAWINGS
CONSTRUCTION NOTES
PROVIDE NEW COMPRESSED AIR PIPING, TYP.
RECEIVED
CITY OF TUKWILA
NOV 1 2 2013
PERMIT CENTER
90% SUBMITTAL
ISSUED FOR PERMIT
2-81 BUILDING
KEY PLAN
MAA MIS
O
,!
I\\I\i
Wood
Harbinger
woo DAN Are NE
Butte too
Bellevue IVA 90uo4
405409.6000
rooa6ar6ager.mm
SIM
A
REVISION
RECORD DRAWING J1972197-00
CDC RELOCATION - WIRE SHOP RELOCATION 419760
BI
HGI/SHS
WH
APPROVED
DATE
SYN
REVISION
BY
NPPROVED
DATE
11.12.99
MBL
10.22.13
BOE/A/6®
ACCEPTABILITY
TOO DESIGN 019/OR
SPECIFICATION 6 APPROVED
APPROVED BY DEPT. DATE
TRAVM
IA HOLT
OWNED
ANKLIN
k LLr6
C. FRANEK
CHECKED
G. SPRAGUE
DATE
12.15.97
3.30.98
SUBTILE
PLUMBING
CURRENT REVISION
J#19760
SriBOL
A
DATE
10.22.13
12.15.97
6.3.98
RINED
L COSTELLO
6.3.98
APPROVED
R. MCNIESH
6.3.98
TITLE WIRE SHOP RELOCATION TO 2-81
MECHANICAL MASTER
BUILDING 2-81
COL. A -F/1-3 PLANT 2
SHEET 1 M 110
JOB NO. 972197-00
CONP NO.
OMD NO.
2-61-1M1 O Page 10 of 27
VEaIIbt LL
12[1
I2Ei�
CORRIDPR
13E11 I
1=
AV AT HIGH POINT
MATCHLINE SEE SHEET
x
1 1/2" SAN
DN
{
6" RWL
(TYP OF 2)
Mr
A
24"X24"X24"
SUMP
1 1/2" COPPER
NO HUB, NO
HUB BANDS
3
INSTRUMENTATION VAN
STAGING AREA - N20S11
1/2"
WOMEN'S
I 12J2 1
`11th
12K1
MATCHLINE SEE SHEET 2-81-1M113 (` " 2"
PLUMBING
SCALE: 1/8"=1'-0"
O
1 1/2"
1 1/4"
3"
L
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
LEGEND
POINT OF CONNECTION
GENERAL NOTES
FOR RISER DIAGRAM SEE 2-81-U511.
REFERENCE DRAWINGS
CONSTRUCTION NOTES
I> PROVIDE NEW COMPRESSED AIR PIPING, TYP
PROVIDE NEW 2'A CONNECTION TO EXISTING
2" A PIPE
2-81 BUILDING
RECEIVEDKEYRoLL oL"" O
CITY OF TUKWILA
NOV 1 2 2013
PERMIT CENTER
90% SUBMITTAL
ISSUED FOR PERMIT
II,
Wood
Harbinger
3009 lulls AIIe NE,
Suite M»
Bellevue WA 98004
40330.6000
wo0AurMnfer.ccm
SYM
REVISION
A
B
RECORD DRAWING
CDC RELOCATION - PALLET RACK MOVE
CDC RELOCATION - WIRE SHOP RELOCATION
4972197-00
419760
3119760
BT
HGI/SHS
WH
WH
APPROVED
DATE
$YM
BT
APPROVED
DATE
MBL
MBL
11.12.99
09.12.13
10.22.13
gLASFAKEIAW
ACCEPTABILITY
T116 DESIGN AND/OR
SPECIFCATION IS APPROVED
DRAWN
M. HOLT
CHECKED
S. FRANKLIN
091E
12.15.97
3.30.98
PLUMBING
CURRENT REVISION
J1119760
SYMBOL
B
DATE
10.22.13
APPROVED BY DEPT. DATE
EN(,9Ltf
G. FRANEK
EHECKED
G. SPRAGUE
12.15.97
6.3.98
APPROVED
L COSTELLO
6.3.98
APPROVED
R. MCNIESH
6.3.98
TDLE WIRE SHOP RELOCATION TO 2-81
MECHANICAL MASTER
BUILDING 2-81
COL. F -L/1-3
PLANT 2
SHEE, 1 M 111
JOB N0.
972197-00
COMP N0.
DWG N0.
2-81-1M1 1 Page 11 of 27
30'-0"
(y)
SHIPPING AID
RECIEVINL - N16
1/2"
30'-0"
30'-0"
CO 1
30'-0"
CORRIDOR
1101
Ei
1 1/4"
2 1/2"
1/
TRANSD
ORD CA
IIII
Illli
MS I us
4" WASTE UP
MS I IL`
0 MI
CO�
J
D 1/2"
ELECTRICAL
14E3J 1
3" P -TRAP
BELOW & UP
TO J -SINK
2"V
1M112IM454\
N\
N
FIELD TEST
BUILDUP - N10
L1364 I
TABLE mc-.1
TAB E p
TABLE
30x6,
ABLE
SOnn
RWL
IiB5
a;S M,'S
U./5 M/S I
0
ELEVATOR
MACH. ROOM
1 11E1 _I
374" :11E•
111...-."��
• S5
DUPLEX FLEXIBLE
AIR DROP, SEE ' ( "\ (4 TYp)
1M112MM513
VENDING
I 12's
(2) DUPLEX
FLEXIBLE AIR
W1 y DROP, SEE
1M112 M513
DESK
1/2"
2 1/2
1 1/4"--� \ 13E5
1/2"A
m
2
wR
7,7
•
I
N
W
En
N
Li
LO
LiJ
E
H
IWE7;-
anx PCTBC T48LC PCT E7
DESn
PLUMBING
SCALE: 1/8"=1-0"
O
U
v[SiIBULE
li_E/I
L A.,1
S4
(4)
2 1 /2'CW
1 1/2j -IW
1/2"14AC
0
N,
5
M
'01
co
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
GENERAL NOTES
REFERENCE DRAWINGS
CONSTRUCTION NOTES
PROVIDE NEW COMPRESSED AIR PIPING (TVP).
PROVIDE TWO DUPLEX AIR DROPS AT WORK STATION AS
SHOWN. PROVIDE ADJUSTABLE HOSE WITH HOSE CLAMP
SUPPORT WITH OD (TYP). CENTER
DROPS BETWEEN WORK STATIONS.
PROVIDE DUPLEX AIR DROPS AT WORK STATION AS
SHOWN. PROVIDE ADJUSTABLE HOSE WITH HOSE CLAMP
SUPPORT WITH OD (TYP) CENTER DROPS BETWEEN
WORK STATIONS.
PROVIDE COMPRESSED AIR DROP, TYPICAL
City of Tukwila
BUILDING DIVISIVED
-( 8 )
CITY OF TUKWILA
NOV 1 2 2013
PERMIT CENTER
90% SUBMITTAL
ISSUED FOR PERMIT
2-81 BUILDING
KEY PLAN
sAu. rs
0
\\
/A1111
Wood
Harbinger
pee Nath Am NE.
Sully Tm
Bellevue WA 98004
405Aa8.0000
woomarm08er 100
SYM
REVISION
A
B
RECORD DRAWING J1972197-00
SHOP AIR UNE W.0.5944214
LAPTOP HOTELING ID113884-50
CDC RELOCATION - WIRE SHOP RELOCATION J119760
Br
HCI/SHS
WDB
WDB
WH
APPROVED
DATE
SYN
Br
APPROVED
DATE
11 12 99
11/7 07
1.12 12
MBE
10 22 13
g)LIFLY.E,AIG®
ACCEPTABILITY
THS DESIGN AND/OR
SPECIFICATION B APPROVED
DRAWN DATE
U. BOLT 12.8.97
SFIC
S. FRANKLIN 3.30.98
SUBTITLE
PLUMBING
CURRENT REVISION
J#19760
SYMBOL
C
DATE
10.22.13
APPROVED BY DEPT DATE
ENGINEER
G. FRANEK 12.8.97
CHECKED
. SPRAGUE 6.3.98
APPROVED
COSTEU.O 6.3.98
APPROVED
R. MCNIESH 6.3.98
TITLE
MECHANICAL MASTER
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
COL. A -F/3-8 PLANT 2
SHEET
1M112
JOB NO. 972197-00
COMP NO.
DWG N0.
2-81-1M1 2 Page 12 0127
SIM
A
B
30'-0"
0)
30'-0"
30'-0"
Q_j
30'-0"
30'-0"
ED
CORRIDOR
17'-0" 11D3
MATCHUNE SEE SHEET 1M261
18'-B"
_TYP ELEV_
ELEV.
17-0"
(1'CE
SHIPPINt, AND
ECIEVING - N16
1104
1 1/2ANSDUCER
RECORD CAL.- N26 °O
1 128
1 1/4"
H
1"
1:
ELEV. 1E'-8"
TYP ELEV.
17'-0"
ELEV.
1 1/2"0 V 1 1/2" o
16'-1"
ELEV.
1" • 1 1/2"
8" UP TO 2ND FLOOR
1 1/2" 1 1/2"
DRY SPRINKLER FOR
ORDINARY HAZARD
GROUP 2 OCCUPANCY,
(W/IN OUTSIDE CANOPY) ' }
1 1/4"
1" 1"
FE.D TEST
1" BUILP P -1019
3E4 I
1 1/4"
1 1/4"
1"
ELEVATOR CONT
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
() City of Tukwila
BUILDING DIVISION
OL VALVE SEE !�?
1M262 M515
1 1/2" 1 1 2
17'-0"
VENDING
i i5
16'-2"
ELEV.
1135 I
6
1M262 M515
1M262 M515 .
17'-0"
❑ ELEV
REVISION
RECORD DRAWING
LAPTOP HOTELINC
CCC RELOCATION - WIRE SHOP RELOCATION
J1972197-00
ID113884-50
J119760
Ttka"
ELEV 0
1" 1" 1
,r
(7) DRY PENDANT HEADS TO PROTECT UNDER
0 THE 10' WIDE MIL CEILING. I c
0
1 4 1 1 2"
BY
HCI/KIC
WDB
WH
IPPRINED
DATE
SYN
REVSIDN
BY
APPROVED
FIRE PROTECTION
SCALE: 1/8"=1'-0"
DATE
8.7 01
1.12 12
881
10.22 13
gLAWIE,AW
0
ACCEPTABILITY
THS DESIGN AND/OR
SPECIFlGnON IS APPROVED
APPROVED BY DEPT. DATE
DRAWN
K.
S. FRANKLIN
-DATE
06.28.01
7.31.01
7
8
LEGEND
SYM
SPRINKLERS
MODEL
TYPE
TEMP.
NPT
K FAC.
FINISH
o
CENTRAL
A
SSU
165
1/2"
5.6
BR.
•
CENTRAL
GB
RECESSED
155
1/2"
5.6
CHR.
•
CENTRAL
A
DRY PEND.
212
1/2"
5.6
CHR.
CENTRAL
A
SSU
212
1/2"
5.6
BR.
o
CENTRAL
A
SSU
212
1/2"
5.6
BR.
2 -WAY SEISMIC BRACE
X4 -WAY SEISMIC BRACE
GENERAL NOTES
1. SYSTEMS ARE ORDINARY HAZARD, PIPE SCHEDULE (30%
OVERSIZED MAINS) MAX. HEAD SPACING = 130 SQ. FT.
PER HEAD.
2. INSTALLATION TO CONFORM WITH NFPA #13 AND
FACTORY MUTUAL.
3. USE SCH. 40 PIPE FOR 2 1/2" OR SMALLER AND
SCH. 10 FOR 3" PIPE AND LARGER.
4. USE CENTRAL SPRINK CLASS 125 C.I. SCREWED
FITTINGS, WELDED & GROOVED FITTINGS AND COUPLINGS.
5. ALL MATERIAL TO BE NEW, U.L. AND F.M. APPROVED.
6. ALL WELDING TO CONFORM WITH AWS D10.9 AND BE
PERFORMED IN THE SHOP.
7. ALL ELECTRICAL WIRING & PROTECTION OF HEADS FROM
PAINT, BY OTHERS.
REFERENCE DRAWINGS
CONSTRUCTION NOTES
PROVIDE WET PIPE FIRE SPRINKLER PROTECTION IN THIS
AREA PER SPECIFICATIONS MODIFY EXISTING FIRE
SPRINKLER SYSTEM AS REQUIRED. CONNECT TO
EXISTING 6" MAIN.
PROVIDE NEW WET PIPE FIRE SPRINKLER SUPPLY FOR
CORRIDOR SPRINKLER. CONNECT TO EXISTING CAPPED
PIPING AS SHOWN.
RECEIVED
CITY OF TUKWILA
NOV 1 '2 2013
PERMIT CENTER
90% SUBMITTAL
ISSUED FOR REVIEW
SUBTITLE
FIRE PROTECTION
2-81 BUILDING
KEY PLAN
xNE ea
O
Wood
Harbinuer
CURRENT REVISION
J#19760
SYMBOL
B
7009 Muth tree NE.
SUI4 loo
Bellevue WA 98004
Rsbl9.6000
w00mMrDmEecmm
DATE
10.22.13
LNIMR.tN
COSCO
CHEERED
APPROVED
APPROVED
9.4.98
TITLE
MECHANICAL MASTER
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
COL. A -F/3-8
PLANT 2
SNEEt 1M262
JOB NO.
972197-00
COMP NO.
DWG NO.
2-81-1M262 Page 13 of 27
12E3
n
MATCHLINE SEE SHEET 1M261
AN
LIB
1" 1"
DUCER 8: RECO 'L'ur.
'ATION FACILITY - S' 10' CEILING
13F3 I
1"
•
• 1 1/4"
(
18'-11"
TYP ELE
1 1/2
CORRIIOR
I I 3 I
3"
I
2'
P"
2"
2"
2" Aft 1 1/2" -9 1 1/2" -j 1 1/411.1
ELECTRICAL
SHOP - N18.1
I 12°3 110' CEIL NG
1 1/2"
1 1/2" 1
1"
I,
/4" 0
4 h1®000
WOMEN'S
1v
I I2F4 1
II
120
V V
18'-6"
TYP ELEV.
ST' aI
•
MEI'S
1F4) 1{-1,F1
�I1
Et
FACILITY COMPON
6" & TEST PART STORAGE NI2
ELEV.- 1"1 1365
• d' .'6'
® a1 fl
2"
1"
1404
I
SOUND DEMO... -7570
FACILITY - N4 �= -
16'-Oi
TYP ELEV
1404
2 1/2" fTMP
1104
1"
1"
1M263 M514
1 1 4" 1 1 2"
T
!!;F1'_ = y 1 1/4" 1 1/2
Ir
L
II
IIII r{
116 . 6' .{
,b III
r IIII
II 2" DN TO , tet- I_ I
II ANEHOIC REVERBII
/ Tfi' h
FACILITY SEE ) .I ELEV.
II
II 1M263 M514 Ilij " 1 1/2"
o - o-- T- 1 1 4" 1 1 2"
1"
1"
III III I I
I I 11J
9111
1111
1 1/2"
/4" 1 1/2"
1"
1M2631M514
2"
1M263 M514 \
2"
H1 4"
ELEV.
R' 1CAL LISJfE-NING
p ROOM '
1144.1
• i
0
�1 1/2
1 1/4"
i2H/) 1247 1
1"
TYPE
TEMP.
.
WAVE GUIDE
-1F4/ i3' - N32
•
1"
•
•
1"
CENTRAL
+/12LS"
1 17 •
••
1.1 1/2"
1 1/4"
165
1/2"
1
BR.
•1"
CENTRAL
•
RECESSED
•
'IMAM A Da
•
CONTROL
_FOOM - N32 t_
12J5
12.,1
( 1515=15'`
•
TYP E-tE
•
0
H
WI E TABLE
[°11K3
0
0
2"
ANECHOIC }}
REV .CILITY -X0'7
0
18'-6"
ELEV.
1"
DESPATCH
OVER"
1"
0
0
1"
1"
0
1
0
1 1/2"
12" 072N �A11/2.
TESTING AREA
2" 1146
0
0
1 fz"-
• 1 1/4"-
-0-
-o
h 1%2"
II
( 1 1G
0
1 1/4"
1 1/2"7
HI TEMP
TEST - N31
I 12'07 1 4"
F l
12"
0
1 1/2"
0
2
•1107)
I
0
MTC 2 -TUBE
ROC2c - N30 2
Sqr
i2H/) 1247 1
MODEL
2
1"
1 1/2"
Imo.
1 1 4"
u
RO MI6 N30
TKP
2"
2
BENCH IEBENCH EBENCH
BENCH
r-�
1 1 2"
III
I
T 1;1/2"
1 1/4"
2" ON TO QUIET AIR
TEST FACILITY
OUIE Ib
'TEST FAIM263 M5.499.
I
f4"36
1 1
1"
1"
TI
II
I I
I I
I I
I I
1
I I
1"
1/2' 0 1 1/2" 0 1 1/4"
rTT
PT.
MATERIAL TEST CENTER
FLOW ROOM - N30
I 114;
2' 1 1 2"
K S4 )
1'
1"
2" 1 1
1"
TYP
0
0
0
1" ▪ �(11K7U
18' -
NMI
t�
MINIM
S AIRS 13
FIRE PROTECTION
SCALE: 1/B"=1'-0"
52
5 )
LEGEND
SYM
SPRINKLERS
MODEL
TYPE
TEMP.
NPT
K FAC
FINISH
o
CENTRAL
A
SSU
165
1/2"
5.6
BR.
•
CENTRAL
GB
RECESSED
155
1/2"
5 6
CHR.
►
CENTRAL
A
SSU
212
1/2"
5 6
BR.
al' FLEX CONNECTORS
GENERAL NOTES
1. THE BOEING TUKWILA FIRE PREVENTION DEPARTMENT SHALL BE NOTIFIED
24 HOURS IN ADVANCE OF ALL VALVE CLOSURES, FLUSHING, AND
HYDROSTATIC TESTS ON THE FIRE PROTECTION SYSTEM THE MAXIMUM
DURATION OF A SYSTEM CLOSURE IS B HOURS
2. A CONTRACTOR'S MATERIAL AND TEST CERTIFICATE WILL BE REQUIRED
UPON COMPLETION OF THE TESTING. THE CERTIFICATE MUST BE SIGNED
OFF BY THE BOEING TUKWILA FIRE INSPECTOR DEPARTMENT PRIOR TO
COMMENCING ADDITIONAL WORK ON THE FIRE PROTECTION SYSTEM.
3. FIRE PROTECTION PIPING SHOP DRAWINGS SHALL BE SUBMITTED TO
BOEING FIRE PROTECTION ENGINEERING AND MUST BE APPROVED BEFORE
ANY MODIFICATION TO THE FIRE PROTECTION PIPING SYSTEM BEGINS.
4. REFER TO SPECIFICATIONS FOR MATERIAL REOUIREMENTS
5. HYDROSTATIC TEST: PRESSURE - 225 PSIG, DURATION - 2 HOURS.
6. SEISMIC BRACING SHALL BE INSTALLED IN ACCORDANCE WITH FM
STANDARDS. SEE FM DATA SHEETS 2-8, 'EARTHQUAKE PROTECTION FOR
WATER-BASED FIRE PROTECTION SYSTEMS' FOR SPECIFIC DETAILS.
7. FIRE SPRINKLER SHOP DRAWINGS SHALL INCLUDE THE SPRINKLER
CONTROL VALVE TAG AND LOCATION FOR THE SERVES THE AREA.
8. COORDINATE SPRINKLER HEAD PLACEMENT AND PIPE ROUTING WITH ALL
DISCIPLINES, INCLUDING EXISTING MECHANICAL AND ELECTRICAL
DISCIPLINES.
18'-8" 9. SYSTEMS ARE ORDINARY HAZARD, PIPE SCHEDULE (30% OVERSIZED MAINS)
TYP ELEV. MAX. HEAD SPACING = 130 SQ. FT. PER HEAD.
DO
cD
C
CO
❑
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
{b)
City of Tukwila
BUILDING DIVISION
( 7 )
10. INSTALLATION TO CONFORM WITH NFPA #13 AND FACTORY MUTUAL. ALL
MATERIAL TO BE NEW, U.L. AND F.M. APPROVED ALL WELDING TO
CONFORM WITH AWS D10.9 AND BE PERFORMED IN THE SHOP.
CONSTRUCTION NOTES
• PROVIDE FIRE SPRINKLER SUPPLY TO RACKS AS SHOWN POINT OF
CONNECTION TO EXISTING 4" SPRINKLER MAIN COORDINATE PIPE
ROUTING WITH ALL DISCIPLINES AND PROVIDE ADDITIONAL OFFSETS
AND SPRINKLERS AS REQUIRED. PROVIDE AUXILIARY DRAINS PER
NFPA-13.
2. MODIFY EXISTING FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH
BOEING FIRE PROTECTION ENGINEERING STANDARD D38108 -F,
NFPA-13, FM 2-0 AND FM 2-8, APPLICABLE CODES AND BOEING
FIRE DEPARTMENT REQUIREMENTS. THE FIRE SPRINKLER
CONTRACTOR SHALL PREPARE FIRE SPRINKLER SHOP DRAWINGS AND
HYDRAULIC CALCULATIONS IN ACCORDANCE WITH THESE STANDARDS
AND SUBMIT TO BOEING FIRE PROTECTION ENGINEERING FOR
• MODIFY EXISTING WET PIPE SPRINKLER SYSTEM IN CORRIDOR AREA
TO ACCOMMODATE WALL AND CEILING CHANGES BY ARCHITECTURAL.
RECEIVED
CITY OF TUKWILA
NOV 1 2 2013
PERMIT CENTER
90% SUBMITTAL
ISSUED FOR PERMIT
2-81 BUILDING
KEY PLAN
SMI: Mrs
O
1,11/
Wood
Harbinuer
7009 oath tea NE
Suite Teo
Bellevue WA 98001
4D5.62t600o
wocmurba getcom
SYM
REVISION
A
RECORD DRAWING
CX RELOCATION - PALLET RACK MOVE
CDC RELOCATION - WIRE SHOP RELOCATION
J1972197-00
J119760
J119760
BY
HGI/KLC
WH
WH
APPROVED
DATE
REVISION
BY
APPRO+ED
DATE
8.7 01
MDL
MDL
09.12.13
10.22.13
g)1_1745FE,ArG®
ACCEPTABILITY
THIS DESIGN MND/OR
SPECIFICATION IS APPROVED
-DRAWN
K. COLE
NATE
07.18.01
7.31.01
S. FR NKUN
SUBNRE
FIRE PROTECTION
CURRENT REVISION
.419760
SYMBOL
B
DATE
10.22.13
APPROVED BY DEPT. DATE
CRUNLLN
'CHECKED
9.4.98
APPROVED
APPIMED
TITLE
MECHANICAL MASTER
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
COL. F -L/3-8 PLANT 2
SNEET 1M263
JOB NO.
972197-00
COMP NO.
DWG NO.
2-B1-1 M263 Page 14 of 27
CO
15'-0"
(LD
BLDG. 2-81 BLDG. 2-80
1/2" RL
7/8" RHG
11111
® ONE
�,
E
''
I/ Ii�'rl�/►
1 1
I I
4"CHWS/R
DN
2"HWS/R
DN
L
CCESS
DOOR
120/120
INTAKE HOOD
FOR AHU 5 & 6
15'-0"
=LLt V
EL]
CSC C
UU1-1 9'-0"
SEL DETAIL
RFM3 M500
m f�1
23'-6
8"TWS T
(CA ED)� 4)
8" TWR L J I
r (CA EDD
1 I
I 1
4" CHWS/R
UP 3" CHWS/R
N
C
RFM3 M500
0
Hl1�SEO DFTAIL(�
3 RFM3 M500
DUCTWORK AND HVAC PIPING
SCALE: 1/16"=1'-0"
6
(7)
l
L ,
REVIEWED FOR
CODE COMPLIANCE
APPROVED.
NOV 2 7 2Q13
City of Tukwila
BUILDING DIVISION
LEGEND
CC
HC
RL
RS
RHG
COOLING COIL
HEATING COL
REFRIGERANT LIQUID
REFRIGERANT SUCTION
REGFRIGERANT HOT GAS
GENERAL NOTES
1. INSULATE AND HEAT TRACE CTWS, CTWR, PW, CHWS, CHWR
CHWR, HWS & HWR ON THE ROOF OUTSIDE THE HEATED
BUILDING ENVELOPE INCLUDING THE AIR HANDLING UNIT
VESTIBULE, PER SPECIFICATIONS.
2. SEE MECHANICAL DRAWING 2-81-M1a FOR PENTHOUSE
SCHEDULE.
13>
AHU-2 SHALL HAVE 3 -WAY CHILLED WATER
CONTROL VALVE.
REFERENCE DRAWINGS
CONSTRUCTION NOTES
90% SUBMITTAL
ISSUED FOR PERMIT
RECEIVED
CITY OF TUKWILA
NOV 1,2 2013
PERMIT CENTER
Wood
Harbinger
3009 mth Ave NE
Salt m
Rename WA 98004
Aasaa%Amo
moodhardngn mm
Sal
A
8
REWSON
RECORD DRAWING
RECORD DRAWING
CDC RELOCATION — WIRE SHOP RELOCATION
4972197-00
4982190-00
419760
8)
HGI/SHS
HCl/RB
WH
APPRENO)
DATE
rn
REV6gl1
ev
APPROVED
DATE
11 12.99
03.15 01
MBL
102213
ce;iBOWAS e”•
ACCEPTABILITY
NS DESIGN AND/OR
SPECIFICATION IS APPRa9ED
APPROVED BY DEPT. DATE
WARDELL I� 30.98
CHECNIU
6.NAPIER 5.15.98
SUermE
DUCTWORK AND HVAC PIPING
CURRENT REVIS0N
J#19760
mea B
10.22.13
/ANR
0. F
G. RANEK
1.30.98
CHEC6ED
G. SPRAGUE 1 6.3.98
APPROVED
L COSTELLO 6.3.98
APPROVED
R. MCNIESH 6.3.98
TRIS WIRE SHOP RELOCATION TO 2-81
MECHANICAL MASTER
BUILDING 2-81
PLANT 2
SHEET
RFM3
JOB No. 972197-00
COUP N0.
2-81—RFM3 Page 15 of 27
SYM
A
AIR HANDLING UNITS - AHU-1. AHU-2. AHU-3. AHU-4 & AHU-5
1. THE SOUTH LOW BAY AREA (COLUMNS 26 TO 40) IS SERVED BY THE SOUTH PENTHOUSE SYSTEM.
THE CENTER LOW BAY AREA (COLUMNS 16 TO 26) EXCLUDING THE CALIBRATION LAB IS SERVED
BY THE CENTER PENTHOUSE SYSTEM. EACH AIR HANDLING SYSTEM IS A DUAL DUCT VARIABLE AIR
VOLUME WITH A RETURN FAN, MIXED AIR CHAMBER, AUTOMATIC DAMPERS AND FILTERS. THE
COOLING SIDE HAS A SUPPLY FAN AND CHILLED WATER COOLING COILS. THE HEATING SIDE HAS
A SUPPLY FAN AND HOT WATER HEATING COILS. THE RETURN AIR FOR THE SYSTEM IS DUCTED
BACK TO THE RETURN FAN. BOTH SUPPLY FANS AND THE RETURN FAN IS EQUIPPED WITH A
VARIABLE FREQUENCY DRIVE AND AIR FLOW MONITORING PROBES ON THE FAN INLET.
2. START/STOP
A) THE AIR HANDLING UNITS WILL BE STARTED / STOPPED BASED UPON AN
INDMDUAL OCCUPANCY SCHEDULES FOR EACH UNIT. THESE SCHEDULES CODED
INTO THE CONTROL PROGRAM FOR THE UNIT.
NIGHT OVERRIDE: IF IT IS UNOCCUPIED PERIOD AND A NIGHT OVERRIDE IS MODE
IS INITIATED AT THE ROOM THERMOSTAT THIS WILL START UP THE AHU. THE AHU
WILL OPERATE UNDER STANDARD OPERATING CONDITIONS.
NIGHT LOW LIMIT: THIS MODE WILL NOT START THE AHU. THE LOCAL FAN POWERED BOX WILL
BE ENABLED TO MAINTAIN SPACE TEMPERATURE.
3. TEMPERATURE CONTROL
A) THE HEATING VALVE SHALL BE MODULATED TO MAINTAIN HEATING SET POINT AND CHILLED
WATER VALVE SHALL MODULATE TO MAINTAIN THE COOLING SET POINT. THE MIXED AIR
DAMPERS WILL BE MODULATED TO MAINTAIN MIXED AIR TEMPERATURE. IF THE OUTSIDE AIR
TEMPERATURE IS ABOVE THE RETURN AIR TEMPERATURE THEN THE MIXED AIR DAMPERS
SHALL MODULATE TO A MINIMUM POSITION. WHEN OSA TEMP IS BELOW 75 DEGF SET MAT
SET POINT AT 58 DEGF. WHEN OSA TEMP IS ABOVE 75 DEGF THEN SET THE OSA
DAMPER POSITION PER THE FOLLOWING SCHEDULE:
I) AT 75 DEGF. OSA DAMPER OPEN 100%
II) AT 90 DEGF. OSA DAMPER OPEN 30%
B) THE DISCHARGE AIR TEMPERATURE SET -POINT WILL BE RESET BETWEEN 52 DEG F
AND 62 DEG F BY THE ZONE WITH THE HIGHEST COOLING DEMAND.
C) THE MIXED AIR TEMPERATURE SET -POINT WILL TRACK THE SUPPLY TEMPERATURE
SET POINT. EXCEPT WHEN THE OUTSIDE AIR CONDITIONS ARE BETWEEN 55 DEG F
AND 59 DEG F. DURING THESE CONDITIONS THE MIXED AIR TEMPERATURE SHALL
MAINTAIN 59 DEG F. THIS SEQUENCE ALLOWS THE CHILLER TO OPERATE (LOADING
COOLING COIL WITH RETURN AIR) THROUGH THIS TRANSITION ZONE. IN THIS
TRANSITION ZONE, THE CHILLERS MUST PROVIDE CHILLED WATER TO ENSURE 55 DEG
F DISCHARGE AIR IS PROVIDED TO THE SPACE.
D) MINIMUM OSA SHALL BE MONITORED BY UTILIZING THE SUPPLY FAN CFM AND
THE OSA TEMP, RETURN AIR TEMP, AND MIXED AIR TEMP. THESE
TEMPERATURES & FLOW WILL CALCULATE WHAT PERCENTAGE IS OUTSIDE AIR.
4. PRESSURE CONTROL / CFM OFFSET:
A) THE SUPPLY FAN VFD WILL BE MODULATED TO MAINTAIN DUCT STATIC PRESSURE AT A
VARIABLE SET -POINT.
B) A DIFFERENTIAL PRESSURE TRANSMITTER LOCATED AT THE FAN WILL BE USED TO CONTROL
THE SUPPLY FAN VFD. THE PRESSURE SET -POINT WILL BE RESET FROM 0.5 - 2.5 IN
WC BASED UPON TERMINAL UNIT DAMPER POSITION. IF THE MAXIMUM TERMINAL DAMPER
POSITION IS GREATER THAN 95% OPEN THEN THE STATIC PRESSURE SET -POINT IS
INCREASED BY 0.05 IN WC. IF THE MAXIMUM TERMINAL DAMPER POSITION IS LESS THAN
80 % OPEN THEN THE STATIC PRESSURE SET -POINT IS DECREASED BY 0.05 IN WC. THIS
RESET TO OCCUR EVERY 5 MINUTES.
C) BUILDING STATIC PRESSURE IS MONITORED BY A COMMON OUTDOOR AIR PRESSURE
REFERENCE. THIS SHALL CONSIST OF A PERFORATED CHAMBER LOCATED OUTDOORS AND
OUT OF THE WINDS PATH. THIS COMMON REFERENCE WILL TIE INTO THE 2 SPACE
PRESSURE REFERENCES, ONE FOR EACH FLOOR. THE DDC SYSTEM WILL MONITOR THIS
BUILDING PRESSURE AND RESET THE CFM OFFSET BETWEEN SUPPLY AND RETURN IN
ORDER TO MAINTAIN +0.05 IN WC (ADJ).
D) THE RETURN FAN CFM WILL BE EQUAL TO THE SUPPLY FAN CFM MINUS THE LOCAL EXHAUST
FAN CFM, MINUS THE CFM OFFSET. THIS OFFSET WILL VARY FROM 0 CFM TO 10,000 CFM.
THE OFFSET WILL BE RESET EVERY 5 MINUTES BY 1000 CFM BASED UPON BUILDING STATIC.
B)
C)
5. SAFETIES AND INTERLOCKS
A) LOW LIMIT THERMOSTAT LOCATED BETWEEN THE HEATING AND COOLING COIL WILL SHUT DOWN
THE AHU AND ALARM THE DDC SYSTEM IF THE MIXED AIR TEMPERATURE DROPS BELOW 35
DEG F (ADJUSTABLE). THE LOW LIMIT REQUIRES MANUAL RESET AT THE UNIT. THE HEATING
WATER VALVE WILL BE COMMANDED TO 100% IF A LOW TEMPERATURE SITUATION IS DETECTED.
B) DUCT HIGH STATIC PRESSURE SWITCH SHALL OVERRIDE THE VFD OUTPUT TO PREVENT OVER
PRESSURIZATION OF THE DUCT.
UPON A POWER LOSS SITUATION ALL AHUS, EFS, CHILLERS, AND PUMPS WILL SHUT DOWN AND
THEN STAGE ON IN A SEQUENTIAL AND DELAYED MANNER TO PREVENT EXCESSIVE LOADING.
6. FIRE SYSTEM INTERFACE
A) SUPPLY AND RETURN AIR SMOKE DETECTORS (PROVIDED, INSTALLED AND WIRED BY
DIVISION 16) SHALL SHUT DOWN THE AHU.
B) ON AHU-4 FIRE/SMOKE DAMPERS PROVIDED BY DIVISION 15 AND WIRED BY DMSION 16 SHALL
CLOSE ON SMOKE DETECTION BY EITHER SUPPLY OR RETURN AIR SMOKE DETECTOR..
C) CORRIDOR FIRE/SMOKE DAMPERS PROVIDED BY DMSION 15 AND WIRED BY DIVISION 16 SHALL
CLOSE ON SMOKE DETECTION BY EITHER SUPPLY OR RETURN AIR SMOKE DETECTOR AT THE
CORRESPONDING AIR HANDLING UNIT.
7. UNIT SHUTDOWN
A) UPON AHU SHUTDOWN OR SAFETY INTERLOCK OSA AND EXHAUST AIR DAMPER
WILL CLOSE, SUPPLY AND RETURN FANS STOP, CHILLED WATER VALVE CLOSED,
AND HEATING WATER VALVE CLOSED (EXCEPT IN A FREEZE CONDITION).
8. MORNING WARM UP / COOL DOWN MODE
A) PRIOR TO OCCUPANCY TIME THE FOLLOWING SHALL OCCUR. ALL ZONES WILL BE
LOOKED AT TO DETERMINE IF MORNING WARMUP/COOLDOWN IS NEEDED. BASED
UPON DEVIATION FROM ROOM TEMPERATURE SET -POINT (72 DEG F ADJ.) THE AHU
SYSTEM WILL START FROM 60 MINUTES (ADJ) TO 0 MINUTES EARLY (ADJ) FOR
COOLDOWN. WARM UP SHALL BE PERFORMED BY COMMANDING THE FTUS TO DAY
MODE.
C)
REVISION
ISSUE FOR CONSTRUCTION BLDG. 2-81
RECORD DRAWING
CDC RELOCATION - WIRE SHOP RELOCATION
J#972197-00
Je982190-00
419760
BY
LS/JIM
401/R8
WH
AFFRONT➢
DATE
SYN
REVIEWED FOR
INCE
APPROVED
COMPLIANCE
E®
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
REVISION
BT
APPROVED
AIR HANDLING UNITS - AHU-6 AND EF -5
1. THE AHU-6 SYSTEM IS BEING CONVERTED FROM A 100% OSA MAKEUP AIR UNIT TO A
VARIABLE VOLUME SYSTEM. THE SYSTEM CONSISTS OF AN AIR HANDLING UNIT WITH
HEATING AND COOLING WATER COILS, NEW FAN AND VAV TERMINAL UNITS, AND AN
EXHAUST/RELIEF FAN (EF -5). I AHU-6 WILL HAVE ITS FAN MOTOR REPLACED WITH A NEW
INVERTER DUTY MOTOR AND A NEW VFD TO CONTROL ITS SPEED. EF -5 WILL HAVE ITS
FAN MOTOR REPLACED WITH ANEW INVERTER DUTY MOTOR AND A VFD TO CONTROL ITS
SPEED. THE SYSTEM WILL OPERATE DURING NORMAL OCCUPIED HOURS.
2. WARM-UP MODE: PLACE THE SYSTEM IN WARM-UP MODE BASED ON AN OPTIMIZED
ALGORITHM WHICH COMPARES OUTDOOR AIR TEMPERATURE AND ZONE TEMPERATURE TO
DETERMINE THE AMOUNT OF TIME PRIOR TO OCCUPIED MODE REQUIRED TO HEAT THE
BUILDING TO OCCUPIED SETPOINT.
A. AIR HANDLING UNIT: START THE SUPPLY FAN. MODULATE THE SUPPLY FAN SPEED TO
MAINTAIN DUCT STATIC PRESSURE SETPOINT (INITIALLY SET TO 1.0" WC, FINAL TO BE
DETERMINED BY TESTING AND BALANCING AGENT). SHUT THE MIXING DAMPERS TO 0
PERCENT OUTDOOR AIR AND 0 PERCENT EXHAUST. DISABLE THE COOLING COIL.
MODULATE THE HOT WATER HEATING COIL CONTROL VALVE TO MAINTAIN THE DISCHARGE
AIR TEMPERATURE SETPOINT, (65 DEG F)(ADJ). OPERATE THE SYSTEM IN WARM-UP
MODE UNTIL ALL ZONE OCCUPIED HEATING SETPOINTS ARE SATISFIED OR THE
SCHEDULED DAY MODE PERIOD BEGINS, WHICHEVER OCCURS FIRST.
3. OCCUPIED MODE: PLACE THE SYSTEM IN OCCUPIED MODE IF SCHEDULED TO BE
OCCUPIED.
A. AIR HANDLING UNIT, START; THE SUPPLY FAN. MODULATE THE SUPPLY FAN SPEED TO
MAINTAIN DUCT STATIC PRESSURE. IN HEATING MODE, MODULATE THE HOT WATER
HEATING COIL CONTROL VALVE TO MAINTAIN DISCHARGE AIR TEMPERATURE SETPOINT
(SEE DISCHARGE AIR TEMPERATURE SETPOINT RESET) AND OPEN THE OUTDOOR AIR
DAMPER TO THE MINIMUM OUTDOOR AIR POSITION (SEE MINIMUM OUTDOOR AIR VOLUME
SETPOINT RESET), OPEN THE EXHAUST AIR DAMPER TO 100% AND MODULATE THE
RELIEF FAN SPEED TO MAINTAIN MAXIMUM SPACE STATIC PRESSURE AT PLUS 0.05"
WATER COLUMN (ADJ). IF jN COOLING MODE AND THE ECONOMIZER CYCLE IS ENABLED,
OPEN THE MIXING DAMPERS TO 100 PERCENT OUTDOOR AIR VOLUME, OPEN THE
EXHAUST AIR DAMPER TO 100 PERCENT EXHAUST, MODULATE THE RELIEF FAN TO
MAINTAIN MAXIMUM SPACE STATIC PRESSURE AT PLUS 0.05" WATER COLUMN (ADJ), AND
MODULATE THE COOLING COIL TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT.
IF IN COOLING MODE AND THE ECONOMIZER CYCLE. IS DISABLED, MODULATE THE MIXING
DAMPERS TO MAINTAIN THE MINIMUM OUTDOOR AIR DAMPER POSITION SETPOINT, OPEN
THE EXHAUST AIR DAMPER TO 100%, MODULATE THE RELIEF FAN SPEED TO MAINTAIN
MAXIMUM SPACE STATIC PRESSURE AT PLUS 0.05" WATER COLUMN (ADJ), AND
MODULATE THE COOLING COIL TO MAINTAIN DISCHARGE AIR TEMPERATURE SETPOINT.
4. UNOCCUPIED MODE: PLACE THE SYSTEM IN UNOCCUPIED MODE IF SCHEDULED TO BE
UNOCCUPIED.
A. AIR HANDLING UNIT: STOP THE SUPPLY AND RELIEF FAN. SHUT MIXING DAMPERS TO
0 PERCENT OUTDOOR AIR. CLOSE THE EXHAUST AIR DAMPER. SHUT THE HOT WATER
HEATING VALVE AND DISABLE THE COOLING COIL.
5 TEMPORARY OCCUPANCY MODE:
A. AIR HANDLING UNIT: PLACE THE SYSTEM IN TEMPORARY OCCUPANCY MODE IF
SCHEDULED TO BE UNOCCUPIED AND ANY TERMINAL UNIT ZONE PUSH BUTTON IS
ENGAGED. OPERATE THE SYSTEM THE SAME AS OCCUPIED MODE. AFTER TWO HOURS
(ADJ) RESTORE THE SYSTEMtTO UNOCCUPIED MODE.
6. UNOCCUPIED HEATING MODE: PLACE THE SYSTEM IN UNOCCUPIED HEATING MODE IF
SCHEDULED TO BE UNOCCUPIED AND THE ZONE TEMPERATURE FALLS BELOW 55 DEG F.
OPERATE THE SYSTEM THE SAME AS IN WARM-UP MODE UNTIL THE ZONE TEMPERATURE
REACHES 60 DEG F (ADJ). ONCE THE ZONE TEMPERATURE REACHES 60 DEG F, PLACE
THE SYSTEM BACK IN UNOCCUPIED MODE. PREVENT THE SYSTEM FROM CYCLING MORE
THAN ONCE PER HOUR.
7. DISCHARGE AIR TEMPERATURE SETPOINT RESET: RESET THE DISCHARGE AIR TEMPERATURE
SETPOINT (55 DEGREES F TO 65 DEGREES F) (ADJ) IN 2 DEG F (ADJ) INCREMENTS
PERIODICALLY (10 MINUTES (ADJ)) TO MAINTAIN THE MOST LIMITING ZONE TEMPERATURE AT
ZONE TEMPERATURE SETPOINT BASED ON DAMPER POSITION OF THE TERMINAL UNITS.
8. ECONOMIZER CYCLE: ENABLE THE ECONOMIZER CYCLE IF THE RETURN AIR TEMPERATURE
IS 2 DEG F MORE THAN THE OUTDOOR AIR TEMPERATURE. DISABLE THE ECONOMIZER
CYCLE IF THE RETURN TEMPERATURE IS LESS THAT THE OUTDOOR AIR TEMPERATURE.
9. SMOKE SHUTDOWN: UPON THE' SENSING OF SMOKE IN THE RETURN AIR STREAM, DISABLE
THE SUPPLY AND RELIEF FANS, CLOSE THE OSA AND EXHAUST AIR DAMPERS TO 0
PERCENT. DISABLE THE CONDENSING UNIT AND CLOSE THE HEATING WATER CONTROL
VALVE.
10. SAFETIES AND INTERLOCKS
A. LOW LIMIT THERMOSTAT LOCATED BETWEEN THE HEATING AND COOLING COIL WILL SHUT
DOWN THE AHU AND ALARM ,THE DDC SYSTEM IF THE MIXED AIR TEMPERATURE DROPS
BELOW 35 DEG F (ADJUSTABLE). THE LOW LIMIT REQUIRES MANUAL RESET AT THE
UNIT. THE HEATING WATER VALVE WILL BE COMMANDED TO 100% IF A LOW
TEMPERATURE SITUATION IS DETECTED.
B. DUCT HIGH STATIC PRESSURE SWITCH SHALL OVERRIDE THE VFD OUTPUT TO PREVENT
OVER PRESSURIZATION OF THE DUCT.
C. UPON A POWER LOSS SITUATION ALL AHUS, EFS, CHILLERS, AND PUMPS WILL SHUT
DOWN AND THEN STAGE ON IN A SEQUENTIAL AND DELAYED MANNER TO PREVENT
EXCESSIVE LOADING.
DATE
5.22.98
03.15.01
10.22.13
le;LAFAIEIAW
ACCEPTABILITY
11115 DESIGN AND/0R
SPECIFICATION 6 APPROVED
APPROVED BY DEPT. DATE
0
RECEIVED
CITY OF TUKWILA 6.
CHILLED WATER SYSTEM
I. CHILLED WATER DISTRIBUTION FLOW CONTROL
II
SYSTEM DESCRIPTION:
THIS SYSTEM IS THE CHILLED WATER DISTRIBUTION FOR THE HVAC SYSTEMS IN THE 2-81
BUILDING. THIS SYSTEM CONSISTS OF TWO (2) CENTRIFUGAL PUMPS, WITH VARIABLE
FREQUENCY DRIVES (VSD), SIZED AT 100% CAPACITY EACH AND ARRANGED IN PARALLEL.
THIS SYSTEM WILL BE ARRANGED AS A TERTIARY LOOP DECOUPLED, WITH A COMMON
BYPASS LINE, FROM THE SECONDARY CHW SERVICE. THE SECONDARY CHW LOOP
PROVIDES CHW SERVICE TO THE BUILDING FROM THE 2-85 CUB VIA THE SOUTH YARD
UTILIDOR. THIS SYSTEM IS CONTROLLED BY THE DDC CMCS.
A. TERTIARY LOOP: THE TERTIARY LOOP WILL FUNCTION WHENEVER AN AHU CHILLED WATER
VALVE CALLS FOR COOLING IS OPERATIONAL. THE PUMPS P-5 AND P-6 WILL BE
SWITCHED BASED UPON RUN TIME. ONCE A MONTH THE PUMP WITH THE MOST RUN
TIME WILL SHUT OFF AND THE PUMP WITH THE LEAST RUN TIME WILL START VIA THE DDC
SYSTEM. IF A PUMP 'FAULT' INDICATION IS RECEIVED FROM THE VFD OR IF THE SYSTEM
DIFFERENTIAL DROPS BELOW 1 PSID (SET AS REQUIRED) FOR 10 MINUTES THEN ENABLE
THE LAG PUMP. THE SECONDARY PUMPS VFD WILL MODULATE TO MAINTAIN SYSTEM
SUPPLY PRESSURE DOWNSTREAM AS SENSED BY THE DIFFERENTIAL PRESSURE SENSOR.
THE DDC SYSTEM WILL POLL THE TRANSMITTER FOR THE MINIMUM DIFFERENTIAL. THIS
MINIMUM WILL BE USED FOR CONTROLLING THE SECONDARY PUMPS. TO PREVENT DEAD
HEAD OF THE PUMPS AND TO MAINTAIN CHILLED WATER CIRCULATION, AHU-2 WILL BE
PROVIDED WITH A 3 -WAY VALVE. SECONDARY CHILLED WATER SUPPLY IS MONITORED FOR
FLOW AND TEMPERATURE. THE SECONDARY CHILLED WATER RETURN IS MONITORED FOR
TEMPERATURE.
CHILLED WATER SUPPLY TEMPERATURE CONTROL:
A. CHILLED WATER SUPPLY TEMPERATURE SET -POINT TO BE RESET BY THE DDC SYSTEM.
THE SET -POINT WILL BE RESET BASED ON AHU MAX VALVE POSITION AND LOAD.
THE CHILLED WATER VALVES WILL BE MONITORED FOR MAXIMUM POSITION EVERY 5
MINUTES. IF THE MAXIMUM VALVE POSITION IS 100% THEN THE TEMPERATURE
SET -POINT WILL BE ADJUSTED DOWN BY 0.5 DEG F. IF THE MAXIMUM VALVE
POSITION IS LESS THAN 80% THEN THE SET -POINT WILL BE ADJUSTED UP BY 0.5
DEG F.
B. THE CMCS (DDC) SHALL MODULATE THE TWO-WAY CHWR CONTROL VALVE TO MAINTAIN
CHWS TEMPERATURE SET -POINT.
HOT WATER HEATING SYSTEM
1, THE HOT WATER HEATING SYSTEM CONSISTS OF A COWERTER (HEX -1, SHELL & TUBE
HEAT EXCHANGER), HOT WATER HEATING PUMPS (P-9 AND P-10) AND THE HOT WATER
HEATING PIPING LOOP EXTENDING TO FAN TERMINAL UNITS, HEATING COILS IN NR
HANDLING UNITS , UNIT HEATERS AND HOT WATER FAN COIL UNITS. SYSTEM TO OPERATE
ON A CALL FOR HEATING. ONE HOT WATER HEATING PUMP IS A STANDBY PUMP WITH
100% SYSTEM REDUNDANCY.
2. ONE PUMP IS DESIGNATED AS LEAD AND THE SECOND PUMP IS LAG. ONCE A MONTH
THE PUMPS WILL BE SWITCHED BASED UPON THE LEAST RUN TIME, TO PROVIDE EQUAL
SERVICE OF THE PUMPS. THE PUMPS WILL BE MONITORED FOR STATUS AND FAULT VLA
THE VARIABLE FREQUENCY DRIVE (VFD). UPON LOSS OF STATUS OR FAULT INDICATION
FROM THE LEAD PUMP THE LAG PUMP WILL BE STARTED AUTOMATICALLY VIA THE DDC
SYSTEM.
3. A DIFFERENTIAL PRESSURE TRANSMITTER, LOCATED ON THE 2ND FLOOR, WILL BE USED TO
CONTROL THE SPEED OF THE HEATING WATER VFD PUMPING SYSTEM. DIFFERENTIAL
PRESSURE SET POINT IS RESET BASED ON MAXIMUM VALVE POSITION.
4. HEATING SUPPLY WATER TEMPERATURE WILL BE MAINTAINED VIA 1/3 AND 2/3 HEATING
VALVE SERVING HEX -1. THE STEAM VALVES WILL REMAIN CLOSED (SPRING RETURN
CLOSED) WHEN BOTH PUMP P-9 AND P-10 ARE OFF. UPON PROOF OF OPERATION OF
ONE PUMP THE STEAM VALVES WILL BE STAGED TO MAINTAIN DISCHARGE TEMPERATURE
SET -POINT.
OPENING CLOSING
5
NOV 1,2 2013
PERMIT CENTER
DRAWN
H. WARDELL
2.4.98
DEMAND 1/3 VALVF 2/3 VALVE DEMAND 1/3 VALVE 2/3 VALVE
A) 0% 0% 0% 0%
B) 33% 33% 33% 25% 75% 0%
C) 34% 34% 34% 75% 257. 257.
0) 100% 100% 100% 100% 100% 100%
0% 0%
THE HEATING SUPPLY WATER TEMPERATURE WILL BE RESET FROM 140 DEG F TO 180
DEG F BASED UPON VALVE POSITION. THE TERMINAL UNIT VALVES AND AIR HANDLING
UNIT HEATING VALVES WILL BE SAMPLED EVERY FIVE MINUTES FOR THE MAXIMUM VALVE
POSITION. THIS MAXIMUM POSITION WILL RESET THE SET -POINT EVERY 5 MINUTES BY
.05 PSI. IF THE MAXIMUM IS GREATER THAN 95% THE SET -POINT WILL BE RAISED, IF
THE MAXIMUM IS LESS THAN 80% THAN THE SET -POINT WILL BE LOWERED.
DURING LOW LOAD CONDITIONS THE VFD PUMP WILL BE OPERATING AT A MINIMUM
FREQUENCY. ONE BY-PASS VALVE LOCATED IN MECHANICAL ROOM ADJUSTED TO
CONTROL DIFFERENTIAL PRESSURE AT MIN FREQUENCY. THIS WILL MAINTAIN A MINIMUM
FLOW REGARDLESS OF HEATING LOAD. LANDIS & STAEFA BOEING 2-81
BLDG.
90% SUBMITTAL
ISSUED FOR PERMIT
SUBTITLE
HVAC CONTROL SEQUENCES
101
��IIi1V-
Wood
Harbinger
CURRENT REVISION
J#19760
SYMBOL
rag Nath Mt NE.
Sulix ADD
Bellevue WA 9Boo4
4.54.a60oo
NOOEIBTWngeT.OM1
DATE
10.22.13
IWWNTLN
J. GAVINO
CHECKED
G. SPRAGUE
2.4.98
6.3.98
L CMVED
OSTELLO
APPROVED
6.8.98
TITLE
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
MECHANICAL MASTER PLANT 2
SHEET M310
AM ml
972197-00
DNC NO.
2-81-M310 Page 16 of 27
1183
740 CFM
/�
1384
790 CFM
FT
1
1181
2745 CFM
/� i
1
1183 1284'
740 CFM 510 CFM
n/�
1,zac) 1,zg
0 CFM MIN
43,025 CFM MAX
3090 CFM MIN
43025 CFM MAX
9310 CFM MIN
OSA 52385 CFM MAX
ROOF LINE
ROOF LINE
L 1-07 L�
13C3 11C3 11D3
2810 CFM 2260 CFM 700 CFM
12G7 11F7 12E7
2480 CFM 1400 CFM
2480 CFM
14E5
550 CFM
1070 CFM
13E4
900 CFM
11E5 & 12E5
170 CFM
t o � 1 P
13E1 ' 13C3
2810 CFM
500 CFM
�FT
17400 CFM MIN
52335 CFM MAX
L-�
FT n
1�0 1
14G4 11H4 12G3 12K1 11K3
1310 CFM 900 CFM 530 CFM 550 CFM 1740 CFM
12J5
11DB18
1830 CFM 1300 CFM
w
11DB19
700 CFM
/ 7
110B18
1
110818
1270 CFM 3205 CFM
FT
L1
345 CFM
12DA16
130 CFM
11DA18
120 CFM
11018
n+ /-n-A Fr
tlip L11 1
1 ST FLOOR PROCESS AREA
Fn
klj tv14
13F3 13G5 11G4 12G5 11G5
1250 CFM 1635 CFM 275 CFM 1360 CFM 2310 CFM
11H6
11G7
1620 CFM 780 CFM
11J0
5000 CFM
SVM
ROOF
1;4
REVOON
7600 CFM MAX
1910 CFM MIN
POC
SA -0-
1,±21
A—_
1
EA FROM PLENUM 5700 CFM
DA
L1
132
450 CFM 1700 CFM
v
MEZZ
7800 CFM MAX
1910 CFM MIN
RA
FROM
PLENUM
1160 CFM MIN EA
7085 CFM MAX —
DA
RECORD DRAWING
4972197-00
HGI/SHS
11.12.99
CX RELOCATION - WIRE SHOP RELOCATION
419760
WH
MBL
10.22.13
el___AVAPEZAW°
3000 CFM MIN
8385 CFM MAX
v
MEZZ
1160 CFM MIN
7085 CFM MAX
ACCEPTABILITY
TUG DESIGN AND/OR
SPECIFICATION IS APPROVED
APPROVED BV
DEPT.
DATE
DRAWN
R. TOPNESS
'CHEERED
S. FRANKLIN
'LNWNLEN
G. FRAMER
CHECKED
G. SPRAGUE
DATE
11.3.97
3000 CFM MIN
8385 CFM MAX
1620 CFM 1230 CFM 1230 CFM
,FT
1
1840 CFM
12H7 1
190 CFM
95 CFM
165IEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
1845 CFM
90% SUBMITTAL
ISSUED FOR PERMIT
3.30.98
HVAC FLOW DIAGRAM
11T2 CFM REdE VED
CITY OF TUKWILA
NOV 1 '2 2013
PERMIT CENTER
Itu
il�lllllll
Wood
Harbinger
COMM REVISION
Jll19760
SYMeDL
3no9 Lath tee NE.
Suite 100
Bellevue WA gimp
405.608.6000
M006INfbIReeENO
DATE
10.22.13
11.3.97
6.3.98
APPIUNED
L GOSTELLO
6.3.98
APPROVED
R. MCNIESH
6.3.98
IDLE WIRE SHOP RELOCATION TO 2-81
MECHANICAL MASTER
BUILDING 2-81
PLANT 2
SHEET
M311
JOB NO.
972197-00
COMP NO
DWG N0.
2-81-M311 Page 17 of
27
2X1"
SVM
3/4" CHWS/CHWR
BY COLUMN F-4
1" CHWS/R
BY COLUMN
C-1
5 MICRON
FILTER
1"x3/4" 1"x3/4"
1"x3/4" 1'x3/4"
1
FIRST FLOOR
SECOND FLOOR
8"x4"
4"X3"
2" CHWR
c
REVISION
RECORD DRAWING J4972197-00
A
CDC RELOCATION - WIRE SHOP RELOCATION J.19760
DY
HGI/SHS
WH
APPROVED
DATE
L)
U
4"x2" 4"x1"
U
4" CHWR
2"xl"
4"X1"
1" VALVES & CAPS
FOR FUTURE CONN.
(TYP 3)
T T
re- re -
2"X1"
U,
U
Tr
U
SVM
REVISION
DY
APPROVED
DATE
11.12.99
TIBC
10.22.13
6"X4"
6" CHWS
6" CHWR
U
4"
CC
U
CHILLED WATER - PIPING DIAGRAM
II
8" CHWS
8" CHWR
8"x6"
_{› 3" CHWS
6"x4"
fD 3" CHWR
6"x4"
ACCEPTABILITY
TAO DESIGN AND/OR
SPECIFICATION S APPROVED
APPROVED BY DEPT. DATE
DRAWN
G. KREWIN
CHWS
\ 2-80-M321 \
8" CHWR
2-80-M321
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
DATE-
2
ATE2 3.98
24.98
S.FRANKLIN
/1.N4WLLN
E. YOOSEFIAN
POC = POINT OF CONNECTION
90% SUBMITTAL
ISSUED FOR PERMIT
SUBTITLE
CHILLED WATER
PIPING DIAGRAM
GENERAL NOTES
REFERENCE DRAWINGS
CONSTRUCTION NOTES
RECEIVED
CITY OF TUKWILA
NOV 1 2013
PERMIT CENTER
III
Wood
Harbinger
CURRENT REVISION
419760
SYMBOL A
WON Ruh AVe NE.
Suite m
Bellevue WA 98000
425.64.6°0o
w00Ehardngecmm
DATE 10.22.13
CHECKo
G. SPRAGUE
L PROWDLLO
ED -
R. MC
R. MCNIESH
2 4.98
6 3.98
6 3.98
6 3.98
TITLE
MECHANICAL MASTER
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
PLANT 2
M319
.WB N0.
972197-00
COMP ND.
DOG N0.
2-81-M319 Page 18 of 27
Mir! 1n/TI /In i1
3/4"
1.2 GPM
3/4"
3/4"x3/4"
2"x3/4"
3/4"
3"x3/4" 2"x3/4"
2"x3/4"
3/4"x3/4"
3"x3/4"
2"x1"
2"x3/4"
(t) a
3"x3/4"
3/4"
2"x3/4"
3"x3/4"
3"xl"
DC
x
3/4"
2'
HWR
HWS
3"
3/4"
3"x3/4"
2"x1 1/2'—\b
LEGEND
1 1/2"x1"
1 1/2"x3/4"
1 1/2"
3"x1 1/2"
1" VALVED & CAP
FUTURE CONNECTIONS
TYP. 3
2"x1
3'x3/4
3" HWS
3" HWR
/ FROM
\ 2-81-M320 \
2-81%320 >
3"x3/4"
3/4"
1"x3/
3/4"
1=
3"x3/4"
1-11-
1"x3/4"
1 1/2"x1"
1 1/2"x
3"x3/4"
HQ -
1
o -1 1/2"x3/4"
1 "x3/4"
101
3/4"
0.9 GPM
1 1/2" 3"x1 1/2
3"x2"
FT
1-114
3.75 GPM
1
3/4"
3"x3/4'
2"x3/4"
3"x3/4""
4-2"x3/4"
3"x3/4
2"x3/4" �%
3"x3/4=- 1
2"x3/4" /�
3"x3/4J—
L
2"x3/4"
3/4"
1-0
3.0 GPM
3"x3/4
11)
1"x3/4" 3/4"
3"x3/4"
3/4"F
3 3
x x
2"x3/4"
z"x1 1/2"
I I
I IWR
2"x3/4" 3'
3"x3/4"
1/2"x3/4"
14)
1 1/2"x3/4"
`3"x3/4"
1 1/2 x3/4"
3"x3/4""
3"x3/4J 1
L(-
-191
3/4"
3/4"
3/4"
3/4'
-60
3/4'
3/4"
3/4"
2.0 GPM
n
2.0 GPM
3.0 GPM
DUCTWORK
SCALE: 1/8"=1'-0"
4.0 GPM
4.0 GPM
O
3/4"
GENERAL NOTES
REFERENCE DRAWINGS
REVIEWED F
APPROVED FOR
COMPLIANCE
ROVED
NOV 2 7 2013
BUILDING
pIVISION
CONSTRUCTION NOTES
RECEIVED
CITY OF TUKWILA
NOV 1 2 2013
PERMIT CENTER
90% SUBMITTAL
ISSUED FOR PERMIT
11;ii11
Wood
Harbinger
pop urth PAR NE
Suite m
Elegem o WA 98x04
425428.6OOD
wmARarthgetmm
SYM
A
REVISION
RECORD DRAWING Jj972197-00
CDC RELOCATION — WIRE SHOP RELOCATION JI19760
ErE
HCI/SHS
WH
APPROAED
DATE
SYM
REVISION
FR
APPROVED
DATE
11.12.99
881.
10.22.13
g)LArgerrAw
ACCEPTABILITY
This DESIGN AND/OR
SPECIFICATION 6 APPROVED
APPROVED BY DEPT. DATE
DRAWN
SIN
S. FRANKUN
DATE
3.12.98
5.18.98
SUBTR E
FIRST FLOOR HEATING WATER
PIPING DIAGRAM
EYOOSEFIAN
ZNLCKED
G. SPRAGUE
3.12.98
6.3.98
APPROVED
L COSTELLO
6.3.98
APPROVED
R. MCNIESH
6.3.98
TITLE
MECHANICAL MASTER
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
PLANT 2
CURRENT REVISION
4/ 19760
s11EET
NO. M321
JOB
SYMBOL
A
DATE
10.22.13
972197-00
COMP N0.
DWS NO.
2-81—M321 Page 190127
EXHAUST FAN EF—OS `\ //
REFERENCE TO
OUTDOORS
WDM601 • �W
r%
CSR -05
PDS601
SPACE
DIFFERENTIAL
PRESSURE
PROOF ALARM START SPEED DAMPER END
"A".05PRF POSITION SWITCH
8.4
"A"=PL2.081.RFE04.XFN
AI
DIFFERENTIAL
PRESSURE
"A"=PL2.0B1.1MC06.SFN
"B"=PL2.0B1.1MDO6.SFN
OSA DAMPER
POSITION
ND SWITCH
"C".O6ES
4.3
5.1
"C"=PL2.0B1.RFE05.SFN
"D"=PL2.081.1SD06.SFN
AO
DAMPER
POSITION
DI
END
SWITCH
"E"=PL2.081.1 MC07.XFN
HWS t--
DI
FILTER
"A".O6FLTR
8.1
TCV601
HEAT COIL
A".06HCV
27.2
AHU-6
SCALE: 1/8"=1'-0—O "
TCV602
CWS
TSL601
•
COOLING COIL FREEZE
"A".06CCV "A".O6LTD
27.1 6.2
CSR601
X
E DO m
ALARM
START SPEED
A".06SS
3.1
REVIEVVE
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
PROO
"A".06
4.4
O
s0 >
000
11601
M327 1E212
11602
M327 1E212
® AI
DUCT DISCH TEMP
STATIC "D".06DAT
PRESSURE 24.1
M327 E517
ROOM TEMP
"B".06IRT
24.2
ITEM
SEQUENCE OF OPERATIONS
1. REFER TO SHEET M310 FOR AHU-6 AND
EF -05 SEQUENCE OF OPERATIONS.
GENERAL NOTES:
1. ALL POINTS SHOWN LAND IN MBC 274
LTD CUT—OUT RELAY LOCATED IN SUPPLY FAN DISCONNECT
13 > SAFETIES HARD—WIRED TO SUPPLY FAN
4 > DAMPER LOCATED AT GRID E,5 ON ROOF TOP
5 > INTERPOSING RELAY FOR EXHAUST FAN LOCATED AT DISCONNECT
REFERENCE DRAWINGS:
2-81—E517
2-81—RFE210
2-81—E521
2-81-1E212
CONSTRUCTION v NOTES
NEW VFD. PROVIDE ASSOCIATED CONTROLS.
REFER TO RFM12 AND M1M456 FOR LOCATIONS.
COORDINATE WITH ELECTRICAL.
PROVIDE NEW CONTROL DAMPER AND ASSOCIATED
CONTROLS.
PROVIDE NEW CONTROL DEVICE AND ASSOCIATED
CONTROLS.
® REPLACE MOTOR PER SCHEDULE.
MATERIAL LIST
PART NUMBER SUPPLIER
RECEIVED
CITY OF TUKWI
NOV 1 2 2013
PERMIT CENTER
DMR6011
H908
GCA161.1P
FOS 601
141 US/4
V RIS CURRENT SENSING RELAY
LANDIS . STALFA, 24VAC SR 0-10VDC MOD
LANDIS & SIAEFA, U.5-1' PRESSURE SWIIUH
TCV 6 1
296-03214
TCV 6 2
296-03197
TSL 6 1
134 1504
SIZE 1.5: CV 25, 40 GPM, 2.6 DROP
SIZE 2.0 , CV 40, 88 GPM 4.8 DROP
LANDIS & STAEFA DPST MANUA RESET
TT 601
TT 602
544 344
LANUIS & SIALFA, 24 RIGID AVERAGING
544 300
LANDIS & SIAEFA, ROOM SENSOR
CSR -05
HROO
CSR -09
HB00
uFR15 EURRENT SENSING RELAY
90% SUBMITTAL
ISSUED FOR PERMIT
IU
lig\
Wood
Harbinger
RTO9 Tuth A•e NE.
SMITL• L00
Bene me WA 99004
4a 6000
w0Comad Kecmm
REVISCW
AS -BUILT J/972197-00
CDC RELOCATION - WIRE SHOP RELOCATION J119760
BY
ASC
WH
APPRO+ED
1P
NEIL
MTE
06.23.99
10.22.13
SYM
REVISION
8f
APPROVED
DATE
ce:LAFAIEIAW
ACCEPTABILITY
1116 DESIGN AND/OR
SPECIFICATION IS APPROVED
DRAWN
J. WEGUNSKI
CHECKED
DATE
04.09.98
AHU-6 P&ID
CURRENT REVISION
419760
SYMBOL
A
DATE
10.22.13
APPROVED BY DEPT. DATE
J. WEG U
J. EGUNSKI
CHECKED
G. SPRAGUE
04.09.98
06.03.98
ROVED
L. COSTELLO
06.03.98
APPROVED
TULE WIRE SHOP RELOCATION TO 2-81
MECHANICAL MASTER
BUILDING 2-81
s'EET M327
JOB NO.
972197-00
COMP NO.
PLANT 2
OWE NO.
2-81—M327 Page 20 0127
TC101
DDC TERMINAL CONTROLLER
ALL SWITCH DAMPER ROOM TEMP
LABEL: "FAN TERMINAL UNIT
ON/OFF SWITCH. TURN
SWTICH TO OFF DURING
TESTS CRITICAL TO SOUND."
roTi VI AI
SW118
1---->E1SW121
SW123
DM102
EXHAUST
DAMPER
E TT101
AIR FLOW DAMPER
Fl Vol
START
DM101
DDC TERMINAL CONTROLLER
START
L///////
FAN
TYPICAL SERIES FAN POWERED BOX
WITH HOT WATER REHEAT
HEAT COIL
TCV101
TCV102
HEATING
COIL
COOLING COIL DISCH TEMP
ROOM TEMP
HEATING
COIL
TYPICAL CABINET HEATER
OT mos
COOLING
COIL
AIR FLOW DAMPER
WI PTI C`�IFATI
H
I I
DM102
DM
TC102
DDC TERMINAL CONTROLLER
ROOM TEMP
TT102
J
REVIEWED
CODE COMPLIANCE
OMLIACE
APPROVED
{
NOV 2 ?, 2013
of Tukwila
City DIVISION
TYPICAL VAV COOLING ONLY
TC103
DDC TERMINAL CONTROLLER
START HEAT COIL ROOM TEMP
AI
RECEIVED
CIITY OF TUKWILA
NOV 12 2013
PERMIT CENTER -
"A" = PL2.081.1 SGO2
"B" = PL2.081.1SJO2
CO OUTSIDE DMPR CO LEVEL
COOAD "A".COALEV
13.1 32.1
AI
"C" = PL2.081.RFE04.XFN
CO LEVEL
"B".COBLEV
32.2
UNIT SWITCH START,
"B".06WS "C".06SS
8.3 11.1 I
PROOF
"C".06SS
8.2
DM105
DM106
DM107
DM108
CARBON
MONOXIDE
METER
CO -1
CARBON
MONOXIDE
METER
CO -2
LOCATE METERS 5' ABOVE FLOOR
MANUAL START
M3301E516
TERMINAL EQUIPMENT P&ID
SCALE: 1/8"=1'-0"
TCV104
ITEM
HEATING
COIL
TYPICAL UNIT HEATER
MATERIAL LIST
OTY PART NUMBER SUPPLIER
M330
E519
M330
E519
O
SERIES FAN PO ERED TERMINAL UNIT OPERATION
1. THE DDC SYSTEM SHALL CONTROL THE OPERATION OF THE FAN, VOLUME OF PRIMARY AIR
AND THE HOT WATER REHEAT COIL IN THE TERMINAL UNITS TO MAINTAIN THE HEATING AND
COOLING SET -POINTS AT THE ROOM TEMPERATURE SENSOR. THE FAN SHALL RUN DURING
THE OCCUPIED PERIOD, NIGHT OVERRIDE AND NIGHT LOW LIMIT MODE. THE ROOMS WILL
HAVE ADJUSTABLE SET -POINTS BY THE OCCUPANTS. THE SET -POINTS WILL BE
COMMANDABLE THROUGH THE DDC SYSTEM.
2. UNOCCUPIED PERIODS, NIGHT OVERRIDE. A PUSH BUTTON AT EACH THERMOSTAT SHALL
ENABLE THE LOCAL FAN AND HEATING COIL FOR 2 HOURS (ADJUSTABLE) TO MAINTAIN ROOM
TEMPERATURE. THE AHU WILL BE STARTED DURING THIS MODE.
FOR EACH AHU ZONE ONE THERMOSTAT WILL BE DESIGNATED FOR NIGHT OVERRIDE. IF
THIS UNIT IS ENERGIZED THE AHU AND ALL TERMINAL UNITS WILL BE STARTED.
3. UNOCCUPIED PERIOD, NIGHT LOW LIMIT. THE LOCAL FAN WILL BE STARTED AND THE
HEATING COIL WILL MODULATE TO MAINTAIN ROOM TEMPERATURE. AHU WILL REMAIN OFF.
4. ALL THE FAN POWERED TERMINAL UNITS SHALL BE STARTED PRIOR TO STARTING THE CENTRAL
AHU TO ENSURE PROPER ROTATION OF SERIES FANS.
5. AIR SHUT OFF_ SWITCH - IF THE WALL MOUNTED AIR SHUT OFF SWITCH IS IN THE "ON"
POSITION, TERMINAL BOX CONTROL OPERATES AS DESCRIBED ABOVE. IF THE SWITCH IS IN THE
"1 " PO MON, THE T RMINAL BO FAN WILL SHUT OFF AND THE CONTROL DAMPER WILL CLOSE
COMPUTER ROOM UNIT MONITORING
1. THE DDC SYSTEM SHALL ALARM ROOM TEMPERATURE SENSORS FOR FT -2-59
SERVING ROOM 22C4 AND F1-2-37 ROOM 22DB22 IF THE TEMPERATURE
IN EITHER ROOM EXCEEDS 78 DEGF.
VAV TERMINAL UNIT OPERATION
1. THE DDC SYSTEM SHALL CONTROL THE OPERATION OF THE AIR VOLUME DAMPER IN THE
TERMINAL UNITS TO MAINTAIN THE COOLING SET -POINT AT THE ROOM
EMPERATURE SENSOR. THE UNIT SHALL HAVE AN OCCUPIED AND UNOCCUPIED SET -POINT
FOR TEMPERATURE AND AIR FLOW. THE ROOMS WILL HAVE ADJUSTABLE SET -POINTS BY
THE OCCUPANTS. THE SET -POINTS WILL BE COMMANDABLE THROUGH THE DDC SYSTEM.
2. UNOCCUPIED PERIODS, NIGHT OVERRIDE. A PUSH BUTTON AT EACH THERMOSTAT WILL BRING
ON THE RESPECTIVE AHU FOR 2 HOURS (ADJUSTABLE).
UNIT HEATERS
1. THE DDC SYSTEM SHALL CONTROL THE FAN AND HEATING WATER VALVE TO MAINTAIN
ROOM TEMPERATURE. UPON A CALL FOR HEATING THE FAN SHALL BE ENABLED AND THE
HEATING WATER VALVE WILL BE MODULATED TO MAINTAIN ROOM TEMPERATURE 70 DEGF (ADJ.).
2. UNOCCUPIED MODE: THE UNIT HEATER WILL CONTROL TO MAINTAIN 60 DEGF.
3. NIGHT OVERRIDE: A PUSH BUTTON AT EACH THERMOSTAT WILL RETURN THE UNIT TO THE
DAY SETPOINT FOR 2 HOURS (ADJUSTABLE).
FAN COIL UNIT FCU -1
1. FCU -1-01 SERVES THE ELECTRICAL ROOM. THE DDC SYSTEM SHALL CONTROL THE SUPPLY
FAN AND CHILLED WATER VALVE TO MAINTAIN ROOM TEMPERATURE. UPON A CALL FOR COOLING
THE FAN SHALL BE ENABLED AND THE COOLING WATER VALVE WILL BE MODULATED TO MAINTAIN
ROOM TEMPERATURE.
CABINET HEATERS
1. THE CABINET HEATERS SHALL BE A PACKAGED UNIT WITH NO DDC INTERFACE.
A LINE VOLTAGE THERMOSTAT OPENS THE VALVE AND RUNS THE FAN WHEN THE
ROOM TEMPERATURE FALLS BELOW 60 DEGF. VALVE CLOSES AND FAN SHUTS DOWN
WHEN THE TEMPERATURE RISES ABOVE 62 DEGF.
CARBON MONOXIDE MONITORING
1. THE CO METERS MONITOR THE CO LEVEL IN THE SPACE. IF EITHER METER
DETECTS A HIGH CO LEVEL, THE DAMPERS WILL OPEN AND THE FAN WILL START.
GENERAL NOTES
1 > TYPICAL OF 3: FT -1-18, FT -1-21, F1-1-23 ONLY.
TYPICAL OF 1: FT -1-23 ONLY.
I 3 > INTERPOSING RELAY FOR EXHAUST FAN LOCATED AT DISCONNECT
14 > INTERPOSING RELAY FOR EXHAUST FAN LOCATED AT MCC
REFERENCE DRAWINGS
2-81-E516 2-81-1E210 2-81-1E213 2-81-2E211 2-81-2E215
2-81-E519 2-81-1E211 2-81-1E215 2-81-2E212 2-81-RFE210
2-81-E536 2-81-1E212 2-81-2E210 2-81-2E213 2-81-E538
CONSTRUCTION NOTES
PROVIDE NEW CONTROLS FOR NEW TERMINAL BOXES AS SHOWN ON 1M12. DEMO
EXISTING CONTROLS FOR EXISTING BOXES BEING REMOVED ON 1M12R.
CS
2
R�STAEEFgA.
DM 101-07
95
34900100
DAMPER
DM 102
349
LA�ApNNNDDDI$$S g& gACTUAATOR
R
DM 105-108
g1
GCA121..10 1P
L NDIS c8 SIAEFA, DAMPERR ACIUAION
T-106
2
134-1086
LANDISDD& STAEFA, LLIyIgqNE TATE
IC
US
540 100
V C�VQ�OL NRR R
TC 103-104
!
540 110
LANDIS & STAFFA. CONDITION CONTROLLER
TCV 101
2
VMP42.09I82
LANDIS &STAEFA, GPM .5 5.0 PD
TCV 102
2
VMP42.10
2 SOS82
LANDIS & SIAEhA GPM .� 5.0 PD
TCV 103
2
VV�MpPy42.11
2 S0SSg8�2
LANDIS & STAEFA
GPM 1.4 S.0# PD
TCV 104
2
$
GPM 5.0 PD
TCV 105
2
VVI4322O4 . 50182
LANDIS & STAEFA.
GPM 15. 5.0# P
TCV 106
3
MTF17 15
IANDIS & STAFFA 7ONF VALVE 1/2"NPT
TCV 107
1
MTE12.15
IANOIC k STAFFA, 7ONF VAI VF 1/7"NPT
TCV 105
1
MTE12 15
LANDIS & STAFFA. 70NE VALVE 1/2"NPT
TT 101-104
112
540 670A
LANDIS & STAEFA. 101( FHd ROOM SENSOR
TT 105
2
535 741
LANDIS & STAEFA. SINGLE DOINT 100K OHM
CO 1-2
2
CM -2B
MACURCO INC. CARBON MONOXIDE MONITOR
90% SUBMITTAL
ISSUED FOR PERMIT
T/)
Wood
Harbinmer
;on Lath Are NE
Sum lop
BeUeLTre WA 9813o4
4asaa6eouo
Kood aHlNQencom
BOA
A
REVISION
AS -BUILT
J/972197
CX RELOCATION - WIRE SHOP RELOCATION .1119760
BI
ASC
WH
APPROVED
TP
NBL
DATE
STU
REVSION
BY
APPROVED
DATE
06.23.99
10.22.13
gifirLIE7AW •
ACCEPTABILITY
THIS DESIGN AND/OR
SPECIFICATION IS APPROVED
APPROVED BY
DEPT.
DATE
DRAWN
J. WEGUNSM
OTIORED
DALE
04.09.98
SUBTITLE
TERMINAL EQUIPMENT P&ID
CURRENT REVISION
Jj)19760
SYYBOL
A
DATE
10.22.13
J. WEGLINSKI
CHECKED
G. SPRAGUE
APPROVED
L. COSTELLO
APPROVED
04.09.98
06.03.98
06.03.98
TITLE
MECHANICAL MASTER
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
PLANT 2
sHEu M330
JOB NO.
972197-00
COUP NO.
DNS NO.
2-81-M330 Page 21 of 27
1 1%2'V
2"V
\1
5'
n
3/4"
.CW
HW
CAPPED (TYP)
2" SAN UP
W
1 1/2"
CAPPED (TYP)
4"FCO
—p 3/4
WHa1❑
2"V n
O
C ❑ ❑
C
J
r1
.3"V, UP
TO ROOF
r 2" CONDENSATE
3
2"UP ;>
TO F
TRAP PRIMER
2" UP TO FD
2'V
V
A
1/2"CW
2" SAN UP
1 1/2v
CAPPED (TYP)-�
0
0 0
z
a
N
4)
2" SAN DN
2"SAN
TRAP
PRIMER
1/2"Cw
1/2" CW
" SAN UP
1 /2"CW
/ -1/2"HW
HWC
1 1/4"
oft
FCO
CAPPED (TYP)
2v
3/4"HW
[*
2" AIR GAP
FITTING Q1
1/2"HW
1 1/2"CW
1/2"CW
1 1/2"V
I
PLUMBING PARTIAL PLAN (
SCALE: 1/4" = 1.-0" .1 M454 1M112
REVIEWED FOR
APPROVED
NOV 2 7 2013
HWC
1 1/2"
1 1/4"
3V
CW_..
H
2 U
I��t
T- N "-
DG J+U3
MASTER
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OFT
NOV1
2013
P►
PERMIT CENTER
SHUT -OF
VALVES
(6)
LEGEND
_R_ REFRIGERANT LINE BY KITCHEN
EQUIPMENT CONTRACTOR
1/2" CW +72 32
L KITCHEN EQUIPMENT TO BE SERVED
(SEE 2-81-A360 FOR SCHEDULE
ROUGH -IN ELEV. (ABOVE FLOOR)
PIPE SIZE AND COMMODITY
GENERAL NOTES
1. FOR CONTINUATION OF PIPING, SEE SHT 1M112.
2 > PROVIDE HOT AND COLD WATER FREEZEPROOF
HOSE BIB.
3 > HOSE REEL.
NOT USED
5 > NOT USED
1 6 > NOT USED
LL% NOT USED
I B > WATER HAMMER ARRESTER WAH-A.
7
90% SUBMITTAL
ISSUED FOR PERMIT
REFERENCE DRAWINGS
1. SEE DWG. 2-81-A460 FOR EQUIPMENT
ITEM NUMBERS.
2. SEE DWG. 2-81-A360 AND A361 FOR
EQUIPMENT SCHEDULE.
CONSTRUCTION NOTES
C> LOCATE 2" AIR GAP FITTING AT
CEILING SPACE..
SLOPE PIPE TOWARDS DIRECTION OF
FLOW AT 1/4" PER FT.
POINT OF CONNECTION TO EXISTING
RISER AT CEILING SPACE. FIELD VERIFY
EXACT LOCATION.
POINT OF CONNECTION TO EXISTING
2"SAN AT CEILING SPACE.
TERMINATE 2"CONDENSATE DRAIN AT
AIR GAP FITTING. PROVIDE
CONNECTION TO 2" SANITARY SEWER
WITH AIR GAP FITTING.
POINT OF CONNECTION TO EXISTING
2"V AT CEILING SPACE.
ROUTE 2"CONDENSATE AND 1"CU THRU
EXISTING BEAM PIPE PENETRATION.
FIELD VERIFY EXACT LOCATION. MAKE
NECESSARY ADJUSTMENT AS REQUIRED.
O
I f/
'MN
Wood
Harbinuer
3009 ssrth Awe NE.
Suite Loo
Be r e WA 98000
WDOBIR16IRgeT.3001
SYM
REVISW
A
RECORD DRAWING 4972197-00
INSTALL ICE MAKER J1585793-00
LAPTOP HOTELING 10113884-50
CCC RELOCATION - WIRE SHOP RELOCATION JI19760
BY
HGI/SHS
WDB
WDB
WH
APPROVED
DATE
SYM
BY
APPROVED
DATE
11.12.99
02.28.08
1.12.12
MBL
10.22.13
1
ACCEPTABILITY
T O DESIGN AND/OR
SPECIFICATION IS APPROVED
APPROVED BY DEPT. DATE
DRAWN
U. HOLT
CHECKED
S. FRANKLIN
PANLJNEtN
G. FRANEK
DATE
1.10.98
3.30.98
SUBTITLE
ENLARGED PLUMBING PLAN
CURRENT REVISION
4119760
SYMBOL
C
DATE
10.22.13
CHECKED
G. SPRAGUE
APPROVED
L. COSTELLO
APPROVED
R. MCNIESH
1.10.98
6.3.98
6.3.98
6.3.98
TITLE
MECHANICAL MASTER
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
COL. E -C/6-7
PLANT 2
SHEET M454
JOB NO.
972197-00
COMP NO.
TWO NO.
2-81-M454 Page 22 of 27
v
LADDER ACCESS
TO MEZZ
TRANSFORMER
Ala
v SEE DETAIL
M1M456 M501
ELECTRICAL PANEL
c
/22'j
X
P
HEATING COILS
COOLING COILS,
ACCESS
I I I
I II
FILTER
1 1/2"
2
SA 66/18
MAINTENANCE
AREA
n
EA��
60/30
SEE DETAIL
4 > M1M456M501
EXTERIOR WALL
2"HWR—B
2"HWS—
3"CHWS-4
3"CHWR—i
36/60
30/60
30/60
TRANS
0 42/2
36/60
36/60
TRANS
TO 60/36
42/24
MEZZ ACCESS HATCI-
60/36
SA
OSA
36/24
M114456M502
42/24
���
ENLARGED MEZZ PLAN
SCALE: 1/4" = i'-0" 1M62,1M1 456
A
(T)
OSA
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
LEGEND
GE►ERAL NOTES
I� PROVIDE 1" DUCT LINER. SEE SPECIFICATIONS FOR
TYPE.
PROVIDE 1" THICK DUCT LINER FOR FIRST 20'
DOWNSTREAM OF AHU-5.
® PROVIDE EXTENDED GREASE FITTINGS FROM BEARINGS
TO INTERNAL PANEL.
15 > CROSS BRACING IS "SWALLOWED" WITH DUCTWORK
AT LOUVER.
REFERENCE DRAWINGS
1. FOR AHU DETAILS, SEE SHEET 2-81-M501.
2. FOR CONTINUATION OF DUCTWORK, SEE SHEET
2-81-1M12.
90% SUBMITTAL
ISSUED FOR PERMIT
CONSTRUCTION NOTES
REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL
INFORMATION.
RECEIVED
CITY OF TUKWILA
NOV ' 1 '2 2013
PERMIT CENTER
Wood
Harbinger
7oO9 u21:11/We NE.
Sapp Leo
Beano WA 98.34
RY,RLE000
woodharDInge.com
SYM
REVISEN
RECORD DRAWING 4972197-00
A
CDC RELOCATION - WIRE SHOP RELOCATION 419760
BY
HCI/SHS
WH
APPROVED
DATE
SYM
REVISION
BY
APPROVED
DATE
11.12.99
11BL
10.22.13
g)LATIZEAriVG®
ACCEPTABILITY
THIS DESIGN AND/OR
SPECIFICATION IS APPROVED
APPROVED BT DEPT. DATE
DRAWN
HGI AN
HGI/SDF
LAUNtLN
HGI/GIF
CHECKED
G. SPRAGUE
DATE
2.4.98
3.30.98
SUBTITLE
MEZZANINE DUCTWORK
CURRENT REVISION
419760
SYMBOL
A
DATE
10.22.13
2.4.98
6.3.98
APPROVED
L. COSTELLO
6.3.98
NC ED
N.
R. NCNIESH
6.3.98
TTTLE WIRE SHOP RELOCATION TO 2-81
MECHANICAL MASTER
BUILDING 2-81
COL. E -C/6-7 PLANT 2
M1M456
JOB NO. 972197-00
COMP NO.
DWG NO.
2 -B1 -M1 M451Page 23 of 27
SIA
A
CLEARANCE: 1/8" PER LINEAR FOOT
BOTH DIRCTIONS
RETAINING ANGLES: MINIMUM •
1 1/2" X 1 1/2" X 0.054(16 GA.)
7
SECURE RETAINING ANGLES TO SLEEVE
ONLY, ON 8" CENTERS WITH:
1. 1/2" LONG WELDS OR
2. 1/4" BOLTS AND NUTS, OR
3. NO. 10 STEEL SCREWS, OR
4. MINIMUM 3/16" STEEL RIVETS.
I-- •
MIN! 1-1
EACH SIDE
STEEL SLEEVE: PER S.M.A.C.N.A.
FIRE DAMPER: BLADE TYPE
1 SECURE DAMPER TO SLEEVE ON
8" CENTERS WITH:
1. 1/2" LONG WELDS OR
2. 1/4" BOLTS AND NUTS IN HOLES
PROVIDED, OR
3. NO. 10 STEEL SCREWS, OR
4. MINIMUM 3/16" STEEL RIVETS.
SECURE DUCT TO SLEEVE WITH A
CONNECTION PER S.M.A.C.N.A.
(TYPICAL)
FIRE/SMOKE DAMPER
SCALE NONE
11)
M506
CONTROL
PANEL
MAINTENANCE
CLEARANCE
L J
CEILING
VIEW
SCALE: NONE
SEE ARCH FOR
BASE FLASHING
AND ROOF CURB
REVB011
M506
TYPICAL INTAKE/EXHAUST
PENTHOUSE
NOTICE: "APPROVED" INSTALLATION
INSTRUCTIONS GOVERN.
SCALE: NONE
RECORD DRAWING 4972197-00
CDC RELOCATION - WIRE SHOP RELOCATION J+19760
BY
HGI/SHS
WH
AMMO
DATE
STU
M506
REVISOR
BY
APPROVED
13>
/14\I -
M506
FAN TERMINAL BOX DETAIL
PRIMARY
SUPPLY
AIR
24'
CLEARANCE
INDUCED
AIR
SUPPLY
J
OT WATER
SUPPLY/RETURN
CONTROL
PANEL
24'
I � %
HOT WATER
SUPPLY/RETURN
J
SCALE: NONE
DUCT CLAMP OR DRAWBAND
AT COLLAR
DATE
11.12.99
MBL
10.22.13
DIFFUSER
I
90 DEGREE RECTANGULAR
TAKE -OFF WITH 45 DEGREE
TAPER
VOLUME DAMPER
UN -LINED AIR
DUCT SAME SIZE
AS GRILLE INLET
LEGEND
GENERAL NOTES
I 1 > DUCT TAP WITH VOLUME DAMPER, FLEXIBLE DUCT, AND
INSULATED SUPPLY DIFFUSER PLENUM BOX WITH SIDE TAP.
2 > LOCATIONS OF HEATI
MI> FLEX CONNECTION.
DUCT MOUNTED SUPPLY GRILLE DETAIL
DUCT HANGER
2 -WAY MODULATING
CONTROL VALVE
UNION (TYP)
AUTOMATIC FLOW
CONTROL VALVE-
PRESSURE/TEMPERATURE
TEST PORT (TYP)
MANUAL AIR VENT
FLEXIBLE CONNECTION
(TYP
HOSE END DRAIN
VALVE CAPPED
SIZE PER PIPING DIAGRAM
ROUND SUSPENDED DIFFUSE
SCALE: NONE
VD
n81111111111.
FLEX DUCT
SECTION
B
SUPPLY AIR DUCT
BLANK PANEL
INSULATED PLENUM BOX W/ SIDE
CONNECTION
SUPPLY DIFFUSER
SCALE: NONE
2M10, 2M11, 2M12, 2M13 M506
e)LAFAREAVG.
ACCEPTABILITY
THIS DESIGN AND/OR
SPECIFICATION IS APPROVED
APPROVED BY DEPT. DATE
-DRAWN
C. DEL.APP
CHECIRD
ANAPIER
DATE
4.14.98
5.15.98
90% SUBMITTAL
ISSUED FOR PERMIT
SUBTITLE
HVAC DETAILS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
REFERENCE DRAWINGS
CONSTRUCTION NOTES
RECEIVED
CITY OF TUKWILA
NOV 1 2 2013
PERMIT CENTER
1U)
Wood
Harbinger
CURRENT REVISION
419760
SYMBOL
A
DATE
7m9 Muth Aye NE.
Suite Too
8NIme WA 95004
4a5Aa&6000
wo001BN11n(esmm
10.22.13
N4WLLR
G. FRANEN
CHECKED
G. SPRAGUE
4.14.98
6.3.98
�LPRovoo
COSTELLO
6.3.98
APPROVED
R. MCNIESH
6.3.98
BRE WIRE SHOP RELOCATION TO 2-81
MECHANICAL MASTER
BUILDING 2-81
PLANT 2
EET M506
JOB N0.
972197-00
COMP N0.
DWG NO.
2-81-M506 Page 24 of 27
PIE
iilli
mow
6"11
I-- •
MIN! 1-1
EACH SIDE
STEEL SLEEVE: PER S.M.A.C.N.A.
FIRE DAMPER: BLADE TYPE
1 SECURE DAMPER TO SLEEVE ON
8" CENTERS WITH:
1. 1/2" LONG WELDS OR
2. 1/4" BOLTS AND NUTS IN HOLES
PROVIDED, OR
3. NO. 10 STEEL SCREWS, OR
4. MINIMUM 3/16" STEEL RIVETS.
SECURE DUCT TO SLEEVE WITH A
CONNECTION PER S.M.A.C.N.A.
(TYPICAL)
FIRE/SMOKE DAMPER
SCALE NONE
11)
M506
CONTROL
PANEL
MAINTENANCE
CLEARANCE
L J
CEILING
VIEW
SCALE: NONE
SEE ARCH FOR
BASE FLASHING
AND ROOF CURB
REVB011
M506
TYPICAL INTAKE/EXHAUST
PENTHOUSE
NOTICE: "APPROVED" INSTALLATION
INSTRUCTIONS GOVERN.
SCALE: NONE
RECORD DRAWING 4972197-00
CDC RELOCATION - WIRE SHOP RELOCATION J+19760
BY
HGI/SHS
WH
AMMO
DATE
STU
M506
REVISOR
BY
APPROVED
13>
/14\I -
M506
FAN TERMINAL BOX DETAIL
PRIMARY
SUPPLY
AIR
24'
CLEARANCE
INDUCED
AIR
SUPPLY
J
OT WATER
SUPPLY/RETURN
CONTROL
PANEL
24'
I � %
HOT WATER
SUPPLY/RETURN
J
SCALE: NONE
DUCT CLAMP OR DRAWBAND
AT COLLAR
DATE
11.12.99
MBL
10.22.13
DIFFUSER
I
90 DEGREE RECTANGULAR
TAKE -OFF WITH 45 DEGREE
TAPER
VOLUME DAMPER
UN -LINED AIR
DUCT SAME SIZE
AS GRILLE INLET
LEGEND
GENERAL NOTES
I 1 > DUCT TAP WITH VOLUME DAMPER, FLEXIBLE DUCT, AND
INSULATED SUPPLY DIFFUSER PLENUM BOX WITH SIDE TAP.
2 > LOCATIONS OF HEATI
MI> FLEX CONNECTION.
DUCT MOUNTED SUPPLY GRILLE DETAIL
DUCT HANGER
2 -WAY MODULATING
CONTROL VALVE
UNION (TYP)
AUTOMATIC FLOW
CONTROL VALVE-
PRESSURE/TEMPERATURE
TEST PORT (TYP)
MANUAL AIR VENT
FLEXIBLE CONNECTION
(TYP
HOSE END DRAIN
VALVE CAPPED
SIZE PER PIPING DIAGRAM
ROUND SUSPENDED DIFFUSE
SCALE: NONE
VD
n81111111111.
FLEX DUCT
SECTION
B
SUPPLY AIR DUCT
BLANK PANEL
INSULATED PLENUM BOX W/ SIDE
CONNECTION
SUPPLY DIFFUSER
SCALE: NONE
2M10, 2M11, 2M12, 2M13 M506
e)LAFAREAVG.
ACCEPTABILITY
THIS DESIGN AND/OR
SPECIFICATION IS APPROVED
APPROVED BY DEPT. DATE
-DRAWN
C. DEL.APP
CHECIRD
ANAPIER
DATE
4.14.98
5.15.98
90% SUBMITTAL
ISSUED FOR PERMIT
SUBTITLE
HVAC DETAILS
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
REFERENCE DRAWINGS
CONSTRUCTION NOTES
RECEIVED
CITY OF TUKWILA
NOV 1 2 2013
PERMIT CENTER
1U)
Wood
Harbinger
CURRENT REVISION
419760
SYMBOL
A
DATE
7m9 Muth Aye NE.
Suite Too
8NIme WA 95004
4a5Aa&6000
wo001BN11n(esmm
10.22.13
N4WLLR
G. FRANEN
CHECKED
G. SPRAGUE
4.14.98
6.3.98
�LPRovoo
COSTELLO
6.3.98
APPROVED
R. MCNIESH
6.3.98
BRE WIRE SHOP RELOCATION TO 2-81
MECHANICAL MASTER
BUILDING 2-81
PLANT 2
EET M506
JOB N0.
972197-00
COMP N0.
DWG NO.
2-81-M506 Page 24 of 27
1/2" STREET
ELBOW TYP
1/2'X3/8"
HEX BUSHING
BALL VALVE
WATTS #B-6080
PIPE SLEEVE
HAND OPERATED
TREADLE
n
1/4" QUICK DISCONNECT
SOCKET, PARKER B22E
1/4' QUICK DISCONNECT
BODY x 3/8"MPT
FLOOR I
100 PSI AIR
FLOOR MOUNTED
DUPLEX AIR OUTLET n
SCALE: NONE M513
DRAIN
IN WALL
FLOOR
1/2"CW
TO BE ROUTED
IN WALL
5
EYE WASH FOUNTAIN DETAIL (P-7)
SCALE: NONE
FLOOR OR
ROOF DRAIN
SYM
A
RUN TO FLOOR OR ROOF DRAIN
SLOPE SHALL BE MIN. 1/4" PER FT
.OF RUN
1
LOCATE 4.-0"
ABOVE FINISHED FLOOR —•�
PARKER EZ-251-6FP
3/8" FPT x 1/4"
SOCKET QUICK
DISCONNECT (TYP)
WALL OR
STRUCTURE
!!! (REF)
WALL BOARD ANCHOR
SCREW AND WASHER
MOLLY BOLT OR
EXPANDING TYPE
ANCHOR (2 PLACES)
B -UNE B-22
CHANNEL OR EQUAL
100 PSI AIR
WALL MOUNTED
DUPLEX AIR OUTLET
CHWS —
REDUCED PRESSURE
BACKFLOW PREVENTER
PD f r
TO FLOOR DRAIN
HYDRAULIC UNIT
(U -D SHAKER SIMILAR)
TO FLOOR
DRAIN
CHWR -�
1" HYDRAULIC PIPE
BY OTHERS
REDUCED PRESSURE BACKFLOW HYDRAULIC TRENCH
PREVENTOR TO HYDAULIC UNIT
SCALE: NONE
PIPING
1M110,1M113,1,60,1M63IM513 SCALE. NONE
REVIEWED FO
CODE COMPLIANCE
APPROVED
NOV 27 2013
rTh
M513
1/2" PIPE NIPPLE (TYP)
1/2" ALL PURPOSE HOSE 200 PSI
BOSTON PERFORMER H11508
1/2" PIPE NIPPLE (TYP)
1/2" ALL PURPOSE HOSE 200 PSI
BOSTON PERFORMER H11508
City of Tukwila
BUILDING DIVISION
PLUG
AIR GAP:
2 TIMES PIPE 0
(MAX. = 2")
REVISOR
EQUAL TO 1/2 STATIC
PRESSURE RATING OF
UNIT PLUS 1"
CONDENSATE DRAIN DETAIL
SCALE: NONE MM13
RECORD DRAWING 4972197-00
CDC RELOCATION - WIRE SHOP RELOCATION 419760
BY
HCI/SHS
WH
APPROVED
DATE
11.12.99
SIM
1/2" ALL PURPOSE HOSE 200 PSI
BOSTON PERFORMER H11508
1/2" ALL PURPOSE HOSE 200 PSI
BOSTON PERFORMER H11508
AHU + FCU DRAIN PAN
1/2" BLK MI ELBOW
ON A DRAW THRU UNIT:
EQUAL TO STATIC PRESSURE
OF UNIT; ON A BLOW THRU UNIT:
EQUAL TO 0"
PIPE SIZE SAME AS UNIT
DRAIN CONNECTION
REVISION
RECEIVED
ITY OF TUKW
PARKER EZ-251-6FP
3/8" FPT, x 1/4"
SOCKET QUICK
DISCONNECT (TYP)
1101 1101
PARKER EZ-251-6FP
3/8" FPT x 1/4"
SOCKET QUICK
DISCONNECT (TYP)
BY
APPROVED
DATE
CEL
10.22.13
cel_4,0E/AVG•
ACCEPTABILITY
THIS DESIGN MND/DR
SPECIFICATION IS APPROVED
APPROVED BY DEPT. DATE
DRAWN
G. KREWIN
MOM
S. FRANKLIN 3.30.98
DATE
3.26.98
/ENGME[N
E. YOOSFIAN 3.26.98
QUADRUPLEX FLEXIBLE
AIR DROP OUTLET
SUBTITLE
PLUMBING DETAILS
NOV 1:2 201
ERMIT CENT
90% SUBMITTAL
ISSUED FOR PERMIT
CURRENT REVISION
972197-00
SYMBOL
A
DATE
10.22.13
CHECKED
G. SPRAGUE 6.3.98
APPROVED -
L. COSTELLO 6.3.98
APPROVED
R. MCNIESH 6.3.98
TOLE
MECHANICAL MASTER
WIRE SHOP RELOCATION TO 2-81
BUILDING 2-81
MBL
SHEET M513
JOB NO.
972197-00
COMP NO.
DWG NO.
2-81-M513 Page 25 of 27
ILA
ER
r.
-T 1
11B5
2'V,UP
hr
12'-10"
9,-7"
CONT'D ON
DWG UGM112
4"FCO
7
CONT'D ON
DWG UGM112
2"FCO
3 � 4 %
i U
1/2"HW-;:-' "CW
4'-2" 5'+0"
LEGEND
_R_ REFRIGERANT LINE BY KITCHEN
EQUIPMENT CONTRACTOR
1/2' CA +72"
ROUGH -IN ELEV. (ABOVE FLOOR)
PIPE SIZE AND COMMODITY
FD FLOOR DRAIN
FS FLOOR SINK
GENERAL NOTES
1. FOR CONTINUATION OF PIPING, SEE SHEET
UGM112.
2 > PROVIDE CATCH BASIN AT DOCK AREA AT
GREASE CONTAINER. SEE NOTE 2,
DWG C305.
3 > PROVIDE 2" PVC SLEEVE FOR ENTIRE
LENGTH OF 1 2" UNDERGROUND TUBING
4 > PIPING ABANDONED IN PLACE AND CAPPED.
CAPPED
2"V,UP (TYP)
2'SAN +12'
4"SAN UP
TO FCO
13'-9" 10'-4 1/2" 14'-7"
FOR
CODE COMPLIANCE
APPROVED
OYU
A
B
0 L
REV90N
RECORD DRAWING J1972197-00
LAPTOP HOTELINC IOf13884-50
CDC RELOCATION - WIRE SHOP RELOCATION J119760
BY
HGI/SHS
WDB
WH
(W1,'
ARE tOvED
DATE
0
NOV 2 7 2013
City of Tukwila
BUILDING DIVISIO
SYM
REVISION
ay
DATE
NEIL
11.12.99
1.12.12
10.22.13
KITCHEN - UNDERGROUND
SCALE: 1/4" = 1'-0" UGM112 UGM455
celeotrsArtc®
ACCEPTABILITY
196 DESIGN AND/OR
SPECIE CATION 6 APPROVED
APPROVED OV DEPT. DATE
IA.
S. FRANKLIN
'LNI,INLLR
G. FRANEK
DATE
12.15.97
3E7
_ 1L
90% SUBMITTAL
ISSUED FOR PERMIT
3.30.98
SUBTITLE
ENLARGED PLUMBING PLAN
REFERENCE DRAWINGS
1. SEE ARCHITECT DWG 2-81-A460 FOR
EQUIPMENT ITEM NUMBERS.
2. SEE ARCHITECT DWG. 2-81-A360 AND
A361 FOR EQUIPMENT SCHEDULE.
CONSTRUCTION NOTES
POINT OF CONNECTION TO EXISTING
UNDERSLAB SANITARY LINE.
RECEIVED
CITY OF TUKWILA
NOV 1 2 2013
PERMIT CENTER
I l'1\)til
Wood
Harbinger
CURRENT REASON
J(J19760
SYMBOL
B
Wog vrth Awe NE.
Sulo too
Belk". WA 91024
wOOdlarbIngel.cOm
DATE
10.22.13
CHECKED
G. SPRAGUE
12.15.98
6.3.98
APPROVED
L COSTELLO
APPROVED
R. UCNIESH
6.3.98
6.3.98
TTTLE WIRE SHOP RELOCATION TO 2-81
MECHANICAL MASTER
BUILDING 2-81
COL. E -C/6-7
PLANT 2
SNEEET UGM455
JOB NO.
972197-00
COMP NO.
ONG NO.
2-81-UGM455Page 26 of 27
PIPE FfTTING SYMBOLS
� VTR
®RD
FD
®FS
® FFD
FUD
PIPING SYMBOLS
REDUCER, CONCENTRIC
REDUCER, ECCENTRIC
UNION, SCREWED
ELBOW, TURNING DOWN OR AWAY
ELBOW, TURNING UP OR TOWARD
TEE, OUTLET DOWN OR AWAY
TEE, OUTLET UP OR TOWARD
CAP, SCREWED OR SOLDER JOINT
BLIND FLANGE
PLUG
CAP, WELDED OR GROOVED
ELBOW, 90'
TEE
CROSS
FITTING SYMBOLS
LATERAL
WCO
WASTE PIPING QUARTER BEND
SANITARY WYE AND 1/8 BEND
ELBOW, 45'
CLEAN OUT, FLOOR
CLEAN OUT, WALL
VENT THRU ROOF
ROOF DRAIN
FLOOR DRAIN
FLOOR SINK
FUNNEL FLOOR DRAIN
FUNNEL DRAIN
VALVE SYMBOLS
--Da—
—104-
-00 —0O
—�$H-
-I.I-
-DDo--
-
-�
—g_
GATE VALVE, OUTSIDE SCREW AND YOKE
GATE VALVE, (NORMALLY OPEN)
GATE VALVE, (NORMALLY CLOSED)
GATE VALVE WITH HOSE CONNECTION
BALL VALVE, (NORMALLY OPEN)
BALL VALVE, (NORMALLY CLOSED)
BUTTERFLY VALVE
GLOBE VALVE, (NORMALLY OPEN)
GLOBE VALVE, (NORMALLY CLOSED)
ANGLE GLOBE VALVE, PLAN
ANGLE GLOBE VALVE, ELEVATION
PLUG VALVE/STOP COCK
CHECK VALVE
3 WAY VALVE
BALANCING VALVE WITHOUT METERING PORTS
BALANCING VALVE WITH METERING PORTS
AUTOMATIC FLOW CONTROL VALVE
NUMBER INDICATES GPM
FLOAT VALVE
NEEDLE VALVE
HOSE BIB
PRESSURE REDUCING/REGULATING VAVE
WITH EXTERNAL PRESSURE TAP
PRESSURE REDUCING/REGULATING VALVE
SELF CONTAINED
PRESSURE RELIEF/SAFETY VALVE
VALVE SYMBOLS CONT.
MOTOR OPERATED VALVE
SOLENOID OPERATED VALVE
3 WAY CONTROL VALVE
CONTROL VALVE
QUICK OPENING
QUICK CLOSING, FUSIBLE LINK
VALVE IN RISER
MISCELLANEOUS PIPING SYMBOLS
EQUIPMENT MARK NUMBER
-7?
POINT OF CONNECTION
AIR VENT, AUTOMATIC (WITH DRAIN)
-,MAV
AIR VENT, MANUAL (WITH DRAIN)
BACKFLOW PREVENTER
COOLING COIL
HEATING COIL
EXPANSION JOINT
FLOWMETER, ORIFICE
FLOWMETER, VENTURI
PRESSURE GAGE WITH VALVE
STRAINER, WYE WITH BLOW OFF
STRAINER, WYE
STRAINER, BASKET
STRAINER, DUPLEX
TEST PLUG (PETE'S PLUG)
TRAP SEAL PRIMER VALVE
—ID— STEAM TRAP
—® VALVE BOX
PIPE GUIDE
PIPE SUPPORT
HANGER
SPRING HANGER
--X— PIPE ANCHOR
® NITROGEN GAS OUTLET, HARD PIPE
® NITROGEN GAS DROP, HOSE
B VACUUM OUTLET, HARD PIPE
• VACUUM DROP. HOSE
IW VACUUM CLEANING OUTLET
Q SIMPLEX AIR DROP, HOSE
DUPLEX AIR DROP, HOSE
e SIMPLEX AIR OUTLET, HARD PIPE
• DUPLEX AIR OUTLET, HARD PIPE
AIR CONDITIONING. REFRIGERATION
AND COOLING SYMBOLS
— CHWS -
- CHWR -
- CLWS-
-CLWR-
- CTFS -
- CTFR —
- CTWR —
— HPWS
— HPWR -
- CLD -
-RS-
-RL-
- RHG —
PIPING IDENTIFICATION SYMBOLS HVAC SYMBOLS CONT.
CHILLED WATER SUPPLY
CHILLED WATER RETURN
COOLING WATER SUPPLY
COOLING WATER RETURN
COOLING TOWER FILTER SUPPLY
COOLING TOWER FILTER RETURN
FROM COOLING TOWER)
DOLING TOWER WATER RETURN
(TO COOLING TOWER)
HEAT PUMP WATER SUPPLY
HEAT PUMP WATER RETURN
CLEAR WATER DRAIN (CONDENSATION)
REFRIGERANT SUCTION (GAS)
REFRIGERANT LIQUID
REFRIGERANT HOT GAS
HEATING SYMBOLS
— HWS — HEATING WATER SUPPLY
— HWR -
- STM-
- HPS —
— MPS -
- LPS
HEATING WATER RETURN
STEAM SUPPLY
HIGH PRESSURE STEAM SUPPLY
(125 - 250 PSIG)
MEDIUM PRESSURE STEAM SUPPLY
(15 - 125 PSIG)
LOW PRESSURE STEAM SUPPLY
(0 - 15 PSIG)
— HPR — CONDENSATE RETURN (PRESSURE), STEAM
— C— CONDENSATE RETURN (GRAVITY), STEAM
— PC — CONDENSATE (PUMPED), STEAM
— CD — CONDENSATE DRAIN -,
— HPC — CONDENSATE, STEAM (HIGH PRESSURE) 1
— MPC — CONDENSATE, STEAM (MEDIUM PRESSURE)
— LPC — CONDENSATE, STEAM (LOW PRESSURE) I
— BBD — BOILER BLOW DOWN
— BFW — BOILER FEED WATER
FUEL OIL SYMBOLS
— FO — FUEL OIL
— FOD — FUEL OIL DISCHARGE
— FOG — FUEL OIL GAUGE
— FOS — FUEL OIL SUPPLY
— FOR — FUEL OIL RETURN
— FOV — FUEL OIL VENT
— FOF — FUEL OIL FILL LINE
PLUMBING AND MISCELLANEOUS SYMBOLS
— A— COMPRESSED AIR (100 PSIG NOMINAL)
— IA — INSTRUMENT AIR
— CF — CHEMICAL FEED
— F— FIRE LINE (AHEAD OF ALARM VALVE)
—S— SPRINKLER LINE
(DOWNSTREAM OF ALARM VALVE)
— G— NATURAL GAS
— LPG — LIQUID PETROLEUM GAS
— LN2 — LIQUID NITROGEN
— GN2 — GASEOUS NITROGEN
— VAC — VACUUM
— CLV — VACUUM CLEANING
PLUMBING AND MISCELLANEOUS SYMBOLS CONT.
- VPD -
-CW-
- HW-
-
HNC -
- DI-
- DW-
- PW-
- AW-
- CRV -
- CRW-
- ID-
- fW-
- SAN -
- STS
-
-RWL—
VACUUM PUMP DISCHARGE
COLD WATER, DOMESTIC
HOT WATER, DOMESTIC
HOT WATER, CIRCULATING DOMESTIC
DEIONIZED WATER
DISTILLED WATER
PROCESS WATER
ACID WASTE
CORROSION RESISTANT VENT
CORROSION RESISTANT WASTE
INDIRECT DRAIN
INDUSTRIAL WASTE
SANITARY WASTE
STORM DRAIN,
RAIN WATER LEADER
—V— VENT
HVAC SYMBOLS
BASIC DUCTWORK SYMBOLS
RECTANGULAR DUCT (FIRST NUMBER
INDICATES SIZE FOR SIDE SHOWN)
240 4
iL
AD
Ea
ROUND DUCT (NUMBER INDICATES DIAMETER)
SUPPLY AIR DUCT,
RECTANGULAR ELBOW TURNING TOWARD
SUPPLY AIR DUCT
RECTANGULAR ELBOW TURNING AWAY
EXHAUST AIR OR RETURN AIR DUCT
RECTANGULAR ELBOW TURNING TOWARD
EXHAUST AIR OR RETURN AIR DUCT
RECTANGULAR ELBOW TURNING AWAY
RECTANGULAR DUCT, SQUARE ELBOW,
SHOWN WITH TURNING VANES
ROUND DUCT,
ELBOW TURNING TOWARD
ROUND DUCT
ELBOW TURN(NG AWAY
FLEXIBLE DUCT
FLEXIBLE DUCT CONNECTION
DUCTWORK AIRFLOW DIRECTION
ACCESS DOOR (AD)
ACCESS PANEL (API
GRILLES. LOUVERS. DIFFUSERS, AND OPENING SYMBOLS
XXX
CFM
�' CFM
,,
RR
RG
ER
EG
SD
SG
SR
TG
SD 12/6
100 CFM
12/6
~ h OO CFM
II_�RG 12/6
Ir100 CFM
SD 12/12
® 400 CFM
0 SD 12/12
400 CFM
SD 12
O 400 CFM
RG 24X24
100 CFM
SUPPLY OR OUTSIDE AIR FLOW DIRECTION
RETURN TRANSFER OR EXHAUST
AIR FLOW DIRECTION
RETURN REGISTER
RETURN GRILLE
EXHAUST REGISTER
EXHAUST GRILL
SUPPLY DIFFUSER
SUPPLY GRILLE
SUPPLY REGISTER
TRANSFER GRILLE
SIDEWALL SUPPLY AIR DIFFUSER,
GRILLE OR REGISTER
SCREENED OPENING
SIDEWALL RETURN/EXHAUST
AIR GRILLE OR REGISTER
SUPPLY OUTLET DIFFUSER,
GRILLE OR REGISTER
SUPPLY OUTLET DIFFUSER,
GRILLE OR REGISTER
SUPPLY OUTLET ROUND DIFFUSER
RETURN/EXHAUST REGISTER OR GRILLE
GRILLES. LOUVERS DIFFUSERS. AND OPENING SYMBOLS CONT.
.1L Di 4. FAN, AXIAL FLOW
LINEAR DIFFUSER
100 CFM
r7ICG 24/24
100 CFM
RETURN/RELIEF GRILLE, CEILING TYPE
NON -DUCTED
DUCT MOUNTED EQUIPMENT SYMBOLS
p CENTRIFIGAL FAN
Q CENTRIFIGAL FAN. INLET GUIDE VANES
C --
—,A
UNIT HEATER
TERMINAL UNIT
INSTRUMENTATION AND CONTROL SYMBOLS
O
H
ZINIM
eP
DUCT TYPE HEAT DETECTOR
DUCT TYPE SMOKE DETECTOR
DUCT TYPE TEMPERATURE SENSOR
CO TEMPERATURE TRANSMITTER
OT THERMOSTAT
OH HUMIDISTAT
ovc4.
DAMPER SYMBOLS
VOLUME DAMPER
OPPOSED BLADE DAMPER
PARALLEL BLADE DAMPER
BACK DRAFT DAMPER (ALLOWS
FLOW IN DIRECTION OF ARROW)
FIRE DAMPER (1 HOUR)
FIRE DAMPER (2 HOUR)
SMOKE DAMPER
FIRE/SMOKE DAMPER
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
FOR REFERENCE ONLY
FACILITY DESIGN BY WH
DATE 09.05. I3
RECEIVED
CITY OF TUKWILA
NOV 1 2 2013
PERMIT CENTER
srM
RECORD DRAWING
4972197 -OD
BY
HGI/SHS
APPROVED
DATE
SYM
REVISION
BY
APPROVED
DATE
11.12.99
gLiroirAtArc•
ACCEPTABILITY
THIS DESIGN AND/OR
SPECIFICATION IS APPROVED
,DRAWN
S. FRANKLIN
DATE
2.18.98
A. NAPIER
3.30.98
SUBTITLE
LEGEND
CURRENT REVISION
SYMBOL
DATE
11.12.99
APPROVED BY
DEPT. DATE
ENGINEER
G. FRANEK
2.18.98
CHECKED
G. SPRAGUE
6.3.98
APPROVED
L COSTELLO
6.3.98
APPROVED
R. YCNIESH 6.3.98
TITLE
MECHANICAL MASTER
BUILDING 2-81
PLANT 2
SHED MO
JOB NO.
972197-00
COMP NO.
OMC NO.
2 -81 -MO Page 27 o127
i PERMIT COORD COPY I'_
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: M13-0207 DATE: 11/12/13
PROJECT NAME: BOEING #2-81
SITE ADDRESS: 8123 EAST MARGINAL WY S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #_
Revision # after Permit Issued
DEPARTMENTS:
tVj
Building Division
Public Works
Pc\4(/
' t '
Fire PreventionI�
Structural
Planning Division
Permit Coordinator
U
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11/14/13
Complete
Incomplete
Not Applicable
111
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg 0
LETTER OF COMPLETENESS MAILED:
Fire ❑ Ping ❑ PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route
,0
Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved ❑
Notation:
REVIEWER'S INITIALS:
Approved with Conditions
DUE DATE: 12/12/13
Not Approved (attach comments) ❑
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Contractors or Tradespeopleter Friendly Page
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name DESIGN AIR LTD UBI No. 600314241
Phone 2538542770 Status Active
Address 8657 South 190Th St License No. DESIGL*212DG
Suite/Apt. License Type Construction Contractor
City Kent Effective Date 3/7/1979
State WA Expiration Date 3/7/2014
Zip 98031 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
MRCCOL'981JB
M C
CONSTRUCTION
CONSTRUCTION LLC
Construction
Contractor
General
Unused
4/2/2002
4/29/2012
Expired
Business Owner Information
Name
Role
Effective Date
Expiration Date
HAGEN, RONALD A
President
01/01/1980
Amount
PORTO, MARK M
Secretary
03/08/2010
g14025755083
MATZ, RICHARD K
Vice President
03/08/2010
Bond Information
Page 1 of 2
Bond
8
Bond Company Name
TRAVELERS CAS a
SURETY CO
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
103742548
03/07/2002
Until Cancelled
$12,000.00
02/28/2002
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
33
Continental Cas
o
g14025755083
10/01/2013
10/01/2014
52,000,000.0009/23/2013
32
Continental Cas
o
GL2095787039
10/01/2012
10/01/2013
$2,000,000.00
10/01/2012
31
Continental Cas
o
GL2095786635
10/01/2011
10/01/2012
$2,000,000.00
09/30/2011
30
CONTINENTAL
CAS CO
GL2095785243
10/01/2010
10/01/2011
$2,000,000.0009/27/2010
29
CONTINENTAL
CAS CO
GL2095786232
10/01/2009
10/01/2010
$2,000,000.00
09/25/2009
28
CONTINENTAL
CAS CO
GL2095785744
10/01/2008
10/01/2009
$2,000,000.00
09/23/2008
27
CONTINENTAL
CAS CO
GL2095785744
10/01/2008
10/01/2009
$2,000,000.00
09/23/2008
26
CONTINENTAL
CAS CO
GL2095783234
10/01/2007
10/01/2008
$2,000,000.00
09/24/2007
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
httns://fortress.wa.gov/lni/bbin/Print.asnx
12/04/2013