HomeMy WebLinkAboutPermit M13-0207 - BOEING #2-81 - ALTERATIONBOEING #2-81 8123 EAST MARGINAL WAY S M13-0207 City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No: 0001600020 Permit Number: M13-0207 Address: 8123 E MARGINAL WAY S 081 Issue Date: 12/4/2013 Permit Expires On: 6/2/2014 Project Name: BOEING #2-81 Owner: Name: BOEING COMPANY THE Address: PO BOX 3707 M/C 20-00 , SEATTLE, WA, 98124 Contact Person: Name: STEVE NIGHSWONGER Phone: (253) 867-1418 Address: 8657 S 190 ST BLDG F , KENT, WA, 98031 Contractor: Name: DESIGN AIR, LTD. Phone: (253) 854-2770 Address: 8657 SOUTH 190TH ST , KENT, WA, 98031 License No: DESIGL*212DG Expiration Date: 3/7/2014 Lender: Name: Address: DESCRIPTION OF WORK: FURNISH AND INSTALL (1) FAN COIL UNIT, (3) TERMINAL UNITS, AND ALL ASSOCIATED DUCTWORK INCLUDING GRDS INSULATION, TEST AND BALANCE, AND CONTROLS. Valuation of Work: $225,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $2,677.13 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: Date: 4ctf3 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development per it and agree to the conditions attached to this permit. Signature: Print Name: v dpisktif),rr- Date: ),Q /I//23 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All construction noise to be in compliance with Chapter 8.22 of the City of Tukwila Municipal Code. A copy can be obtained at City Hall in the office of the City Clerk. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 10: ***MECHANICAL PERMIT CONDITIONS*** 11: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 12: Manufacturers installation instructions shall be available on the job site at the time of inspection. 13: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 14: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 16: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) • • 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 20: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 21: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUK Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://wwvv.TukwilaWA.gov • Mechanical Permit No. M Project No. Date Application Accepted: ' Z.. - Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: Tenant Name: 8Ia3 •7755 East Marginal Way South The Boeing Company PROPERTY OWNER Name: Cele�efkitt5— 4 j-� o� Name: The Boeing Company. Cit': Kent State: WA Zip: 98031 Address: 100 North Riverside Plaza Email: s.nighswonger@design-air.com Cit': Chicago State: IL Zip: 60606 CONTACT PERSON — person receiving all project communication Name: Cele�efkitt5— 4 j-� o� Address: 8657 South 190th Street Bldg. F Cit': Kent State: WA Zip: 98031 Phone.Fax: (253) 854-6131 Email: s.nighswonger@design-air.com Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Furnish and install 1 Fan coil unit, 3 terminal units and all associated duct work including GRD's insulation, test and balance, and controls. 225,000 King Co Assessor's Tax No.: 0001600020 Suite Number: 2-81 Floor: 1st New Tenant: ❑ Yes Z ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Design Air, Ltd. Address: 8657 South 190th Street Bldg. F City: Kent State: WA Zip: 98031 Phone: (253) 854-2770 Fax: (253) 854-6131 Contr Reg No.:600-314-241 Exp Date: 02/28/2014 Tukwila Business License No.: BUS -0994595 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement m Fuel Type: Electric 0 Gas Other: H:\Appltcattons\Fornts-Applications On Line12011 Apphcatwns\Mechamcal Permit Application Revised 8-9-1 Ldocc Revised: August 2011 bh Page 1 of Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu . Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system 4 Air handling unit <10,000 cfm Unit Type Qty Air handling unit . >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct 4 Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment 4 Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. Date: 11/11/2013 Print Name: Steven Nighswonger Day Telephone: (253) 854-2770 Mailing Address: 8657 South 190th Street Bldg. F Kent WA 98031 City State Zip H:Wpplicat,ons\Forns-Applications On Line1201 I Apphcations\Mechanical Permit Application Revised 8-9-I 1.dowc Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT I QUANTITY PermitTRAK PAID $2,834.01 M13-0207 Address: 8123 E MARGINAL WAY S 081 Apn: 0001600020 $2,677.13 MECHANICAL $2,677.13 PERMIT FEE 000.322.100.00.00 $2,109.20 PERMIT ISSUANCE BASE FEE 000.322.100.00.00 $32.50 PLAN CHECK FEE 000.322.102.00.00 $535.43 PG13-0154 Address: 8123 E MARGINAL WAY S 081 Apn: 0001600020 $156.88,; PLUMBING $156.88 PERMIT ISSUANCE BASE FEE 000.322.100.00.00 $32.50 PERMIT FEE 000.322.100.00.00 $93.00 PLAN CHECK FEE 000.322.103.00.00 TOTAL FEES PAID BY RECEIPT: R70 $31.38 $2,834.01 Date Paid: Tuesday, November 12, 2013 Paid By: DESIGN AIR Pay Method: CHECK 98501 Printed: Tuesday, November 12, 2013 10:34 AM 1 of 1 CRWSYSTEMS INSPECTION RECORD_ Retain a copy with permit. INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.,#100, Tukwila. WA 98188 (206) 431-3670 Permit. Inspection. Request Line (206) 431-2451 M/3 )Z7 Project: 1 t, e- 4 >a 2 'Er 1 Ty of Inspection: (Co u 6 if - PIe-�►• \ Address: Date Call d Special Instructions: Dat Wante . A '� ,d -4:,„..,f p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: P eJ i( L -J obc ki)u6Th- Ins Victor: Date_ 0 - j ,y n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy, with permit INSPECTION NO. PERMIT NO. CITY OFTUKWILA' BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA. 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Po' t: Type oUnspection: L Ad es - %. Date. Called: Special Instructions: Date Wanted:- 12-(Z `( t () : ',m- P.m. Requester: Phone No: Approved per applicable codes. COMMENTS: Corrections required prior to approval. ,a. C .1,/,4" -elrt,e- <f --- i' 3 ./ Date: /j 7„,f"/ RE(NPECTION FEE RE'4UMRED. Prior.to next inspection.. fee must be paid at 6300 Southcenter Blvd., Suite 100. Callao schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO: PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd:, #100, Tukwila. WA 98188 (206).431-3670 Permit Inspection Request Line (206) 43.1-2451 Nit "3-0207: Proje t.Type OE t �V Z— /. (- of Inspection: _ r'Gntci !Pk _. Address: s,Z3 ,4,426,,011_ Date Called: Special Instructions: Destek) liiv(4-F4,-- 3__5 S- Sal -2.770 c Ce- i.�i kc i S . Date Wanted: Z i�C� • 1 Cirri) p.m. Requester: eA NJ OT L e -r Phone No: - ng- G%0,1,50 JApproved per applicable codes. " Corrections required p'rior:to approval. COMMENTS: P4 /j(_: . //./0,,, S Inspect® / � ✓ , REINSPECTION FEE R QUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. I Date: fl- 6-13 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit D/3- z /3-5- 299 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project' r, _ 2-•-01 Sprinklers: Type of Inspection: Srv\Z_ F/ / �- / /' ' Address: `) ;Suite #: 53(2. 3 E-7:. t'it ') 113 A ! Contact Per n: / / Special Instructions: ,�, ,t i ,f d / Phone No.: A,0;,....,‘,5‹,/,./ -A--,,, �f O x.c.f..e 4,� Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: it -..ti �lre /i C /' (7�i-z- t / 179 X � 7":6 --- Fis...7^ `, ,�, ,t i ,f d / af/(.., Ai e A,0;,....,‘,5‹,/,./ -A--,,, �f O x.c.f..e 4,� S'O'S c -s .s -77e//t-rt-7 ''— )rt #'i R..1elu.) .. ,44c.vi ,_... 4/4'-w /),,,vdec., frs-vs_ ... e,,, ,7 ,ovikr Peer,;( — f/fd ("It.' 47 2.cif,4 _57.75, ,h_ 94 Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector? Date: //a/// Hrs.:' $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 THE BOEING CO M PA N FILE COP CD CE SHOP MOVE TO 02-81 Ran review approval ..peke to errors and a�iSSb a Approval of construction documents does net a h, 123 E MA RG I NAL WAY the violation of any adopted code or ordinance 4 ;r/ I LA, WASHINGTON 98 1 0 8 ackivwledB U I L D I N G 02-81 JOB # 19760 90% PERMIT SET City Of 1Ukwila BUILDING DIVISION I\ REGIO\ MUKILTEO TO EVERETT Mill 0 LAND REE MOND EVUE rill" Hes ISSAQUAH - ----------- ---_ 1 i BOTHELL t� WOD LYNN DMON1: B' 1 IV _ ,PROJECT ON -- SCALE: SITE �T� EIAXEN NONE _ ETON . 1311 KENT * •AUBURN -===-= TO T•* A AUBURN Y SEPARATE PERMIT REQUIRED FOR: 0 Mechanical -Electrical ta Plumbing fil/Gas Piping City of Tuk�»- la BUILD DIV _ 1O y CODES AND PERMITS PERMITS REQUIRED & FOR REVIEW: ® BUILDING D GRADING ® PLUMBING * ❑ LANDSCAPE ▪ MECHANICAL* ❑ DEMOLITION ® ELECTRICAL * ❑ CIVIL ® FIRE PROTECTION * ❑ STRUCTURAL * TO BE RENEWED UNDER SEPARATE PERMIT WASHINGTON STATE NON-RESIDENTIAL ENERGY CODE COMPLIANCE OPTION ® PRESCRIPTIVE ® LPA ❑ ANALYSIS ❑ N/A SPECIAL INSPECTIONS REQUIRED: ❑ WELD ❑ CONCRETE ❑ REBAR O ANCHOR BOLTS ❑ STRUCTURAL BOLTING ❑ STRUCTURAL OBSERVATION O OTHER CALCULATIONS TYPE: NRGC ATTACHED (YES) (NO) TAX PARCEL NUMBER: 112405-9134 vICI ITY VA SE 3 2-41 2-40 2-44 a 2-5 2-49 2-66 2-65 2-64 I2-80 2-110 0 0 a 2-45 GATE B-18 SITE ACCESS 2-55 e 411.1 PROJECT SITE SCALE: NONE 2-84 2-117 2-116 2-87 REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. LEGAL DESCIPTION APN: 000160-0020 A TRACT OF LAND BETWEEN THE DUWAMISH WATERWAY AS ESTABLISHED BY COMMERCIAL WATERWAY DISTRICT #1 OF KING COUNTY, WASHINGTON AND EAST MARGINAL WAY IN SECTION 33, TOWNSHIP 24 NORTH, RANGE 4 EAST, W.M., AND IN THE JOHN BUCKLEY DONATION CLAIM NO. 42; SAID TRACT ALSO BEING THE SOUTHERLY PORTION OF A LARGER TRACT COMMONLY CALLED THE BOEING COMPANY'S PLANT NUMBER TWO SITE, DESCRIBED AS FOLLOWS: BEGINNING AT THE SECTION CORNER COMMON TO SECTIONS 28, 29, 32, AND 33; THENCE SOUTH 88'08'07" EAST ALONG THE NORTH LINE OF SAID SECTION 33, A DISTANCE OF 982.00 FEET TO AN INTERSECTION WITH THE SOUTHWESTERLY MARGIN OF EAST MARGINAL WAY; THENCE SOUTH 4751'53" EAST ALONG SOUTHWESTERLY MARGIN 684.62 FEET TO THE TRUE POINT OF BEGINNING OF THE TRACT HEREIN DESCRIBED; THENCE SOUTH 4725'24" WEST 1215.02 FEET MORE OR LESS TO A POINT ON THE NORTHEASTERLY MARGIN OF SAID DUWAMISH WATERWAY, SAID POINT BEING ON A CURVE FROM WHENCE THE CENTER BEARS SOUTH 4716'23" WEST 1969.12 FEET; THENCE SOUTH- EASTERLY ALONG SAID CURVE, A DISTANCE OF 397.99 FEET TO THE POINT OF INTERSECTION WITH A LINE LYING 825.00 FEET SOUTH, AS MEASURED AT RIGHT ANGLES, OF THE NORTH LINE OF THE JOHN BUCKLEY DONATION LAND CLAIM NO. 42. THENCE SOUTH 89'09'36" EAST ALONG SAID LINE, PARALLEL WITH THE NORTH LINE OF SAID DONATION LAND CLAIM NO. 42, A DISTANCE OF 1387.45 FEET TO THE WESTERLY MARGIN OF EAST MARGINAL WAY; THENCE NORTH 2732'15" WEST 160.30 FEET, FOLLOWING SAID WESTERLY MARGIN TO THE POINT OF CURVATURE OF A CURVE HAVING A RADIUS 2828.00 FEET; THENCE NORTHWESTERLY ALONG SAID CURVE, A DISTANCE OF 1250.10 FEET TO THE POINT OF TANGENCY OF SAID CURVE; THENCE NORTH 4751'53" WEST 76.82 FEET TO THE TRUE POINT OF BEGINNING: THIS TRACT CONTAINING AN AREA OF 2,897,955 SQUARE FEET, MORE OR LESS. REVItVVED FOR CODE COMPLIANCE APPROVED NOV 27 2013 City of :u ila BUILDING VISION RECEIVED CITY OF TUKWILA NOV ,1 2 2013 PERMIT CENTER CODE SUMMARY TYPE OF APPLICATION: NEW ❑ ALTERATION ❑ ADDITION ❑. TENANT IMPROVEMENT NARRATIVE: 10,275 SF OF TENANT IMPROVEMENT OF THE INTERIOR ONLY ON THE FIRST FLOOR OF THE 02-81 BUILDING. DEMOLITION WILL INCLUDE THE REMOVAL OF FLOOR/CEIUNG FINISH MATERIALS, NON -LOAD BEARING WALLS, PLUMBING FIXTURES AND PORTIONS OF THE HVAC, ELECTRICAL AND PLUMBING. SYSTEMS. TENANT IMPROVEMENT WILL INCLUDE NEW WALLS, CEILINGS, AND FLOOR COVERINGS. NEW MECHANICAL, HVAC, PLUMBING AND FIRE PROTECTION SYSTEMS WILL BE INSTALLED PLUS ELECTRICAL POWER, LIGHTING COMMUNICATION AND DATA SYSTEMS TO SUPPORT THE NEW LAYOUT. IN ADDITION A EXTERIOR PAIR OF DOORS ON THE WEST ELEVATION WILL BE INSTALLED. CODES: 20 INTERNATIONAL BUILDING CODE (WAC 51-50) 20 INTERNATIONAL FIRE CODE (WAC 51-54) 70 INTERNATIONAL MECHANICAL CODE (WAC 51-52) 20 PLUMBING N WASHINGTON STATE ENERGY CODE AND YCODE (WAC 5WAC 51- 2 6 ICC/ANSI A117.1 2 3 ICC A117.1 ACCESSIBILITY CODE C RENT CITY OF TUKWILA ZONING ORDINANCES ORIGINAL CODE: OWNER- THE BOEING COMPANY . CONTRACTOR & STATE NUMBER- TO BE DETERMINED BOEING PROJECT MANAGER: MICHAEL PRITTIE PROJECT DESIGN ARCHITECT / ENGINEER: ERWIN C. ANGULO, DLR GROUP 206-461-6000 206-304-0027 BOEING CONTACT: MICHAEL PRITTIE PHONE- 206-304-0027 FAX NUMBER- TBD E-MAIL MICHAELJ.PRIT11E1280EING.COM ZONING CITY OF TUKWILA OCCUPANCY GROUP. Fl FACTORY INDUSTRIAL CONSTRUCTION TYPE- II -B ALLOWABLE AREA INCREASE- - OCCUPANT LOAD: (ALLOWABLE) SEEA3FOR FLOOR AREA: 62,828 SF/ FLOOR OCCUPANT LOAD: (ACTUAL) PROJECT CODE INFO (PER SECTION 502 DEFINITION OF BUILDING AREA) OFFICES OCC - BLDG GROSS 125,656 STORAGE DCC - BASEMENT ASSEMBLY OCC - FIRST FLOOR CANOPY OCC - SECOND FLOOR OTHER - OCC = THIRD FLOOR PENTHOUSE OCC = FOURTH FLOOR BUILDING HEIGHT: (ACTUAL) UNCHANGED FIFTH FLOOR SIXTH FLOOR PENTHOUSE PROJECT AREA SQ FT SQ FT 62,828 SQ FT 62,828 SO FT SO FT SO FT SO FT SO FT SO FT 10,275 SO FT STORIES- 2 MEZZANINE ? ® (YES) 0 (NO) SQ FT 1 265SF FIRE PROTECTION: SPRINKLERED THROUGHOUT ® (YES) 0 (NO) NFPA 13 AUTOMATIC SPRINKLER SYSTEM IS INSTALLED WITH QUICK RESPONSE HEADS. SEPARATION 2 HOUR AT EXISTING BUILDINGS AND GRID 17 (02-80/02-81) EXTERIOR WALL (NON-BEARING) HOUR RATING EXTERIOR WALL (BEARING) HOUR RATING INTERIOR WALL (NON-BEARING) HOUR RATING INTERIOR WALL (BEARING) HOUR RATING DEMOUNTABLE PARTITIONS HOUR RATING STRUCTURAL FRAME HOUR RATING FLOOR/CEIUNGS HOUR RATING ROOF CONSTRUCTION HOUR RATING SEISMIC CATEGORY: ZONE D DESIGN LOADS: (CHAPTER 23) ROOF: LIVE (SNOW) (PSF) FLOOR: OFFICE (PSF) MECH/STOR (PSF) STAIRS (PSF) PENTHOUSE (PSF) CONCENTRATED. WIND: EXPOSURE NOTE: FOR ADDITIONAL CODE INFORMATION SEE COMPOSITE CODE PLAN SERIES A3 DLR Group 90% SUBMITTAL ISSUED FOR PERMIT 555 REVISION BI ORIO CDC RELOCATION - WIRE SHOP RELOCATION J/19760 DLR GROUP APPROVED EEA DATE 5YM REVISION APPROVED DATE 10.22.13 LBOE/Ar4r ACCEPTABILITY THI5 DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DIRWN DATE =RED SUBTITLE COVER SHEET CURRENT REVISION J#19760 SRBUEQRIG DATE 10.22.13 APPROVED BY NLMELH 'CHECKED APPROVED APPROVED - TITLE WIRE SHOP RELOCATION TO 2-81 VICINITY MAP, LEGAL DESCRIPTION AND CODE SUMMARY ARCHITECTURAL MASTER PLANT2, WA SHEET GO JOB NO. 19760 COMP NO. DWG NO. 2 -81 -GO AA WfYLO1 [JUGULO: 10/22/201 LEGEND/SYMBOLS MATERIAL SYMBOLS ; ABBREVIATIONS GENERAL NOTES PLAN FROM) SPECIFIC MOUNTED) MOUNTED) EMERGENCY FIXTURE FIXTURE EMERGENCY __. DIRT, COMPACTED GRAVEL. POROUS COMMON TILE FILL LOOSE FILL BLANKET GROUT WALL BOARD BLOCKING MASONRY (CMU) 1 STUD STUD ) I I ( (7'-0- HIGH) j p FOR ( ���� I • ( f . I ( i , 1 J 1 I i ( & AND IN INCH 0 Al WCL INCLUDED(D) (INC) AB ANCHOR BOLT JT JOINT ACP ACOUSTICAL CEILING PANG ACT ACOUSTICAL CEIING 111.E K KIP(S) ADI ADJACENT • KO KNOCK OUT AFF ABOVE FINISHED FLOOR Lto LENGTH AL AGGREGATE AL ALUMINUM LENGTH ALT ALTERNATE LEN ALUM ALUMINUM LF LINEAL FEET ARCH ANCHOR, ANCHORAGE LWR Ll COAD AN AMERICAN PLYWOOD ASSOC. APPD APPROVED MARL MATERIAL APPROX APPROXIMATE MAX 50X1505 ADM AMERICAN SORELY OF MB MACHINE BOLT TESTING MATERWS MBR MEMBER BTWN BETWEEN MR METAL BLDG BUILDING MFR MANUFACTURE(R) BLKG BLOCKING MIN MINIMUM BD BOTTOM OF 5150 MISCELLANEOUS 801 BOLTON MO MT MASONRY OPENING MOUNT(ED) (INC) C CHANNEL MTL METAL CB CATCH BASIN CC CENTER TO CENTER N NORTH (COORDINATE) CEM CEMENT NF NEAR FACE CF CUBIC FEET NIC NOT IN CONTRACT CFO CONTRACTOR FURNISHED CONTRACTOR INSTALLED NO. NUMBER CG CORNER GUARD NOM NOMINAL CJ CONTROL JOINT NTS NOT TO SCALE CL CENTER UNE CLG CEILING OA OVERALL CUR CLEAR(MCE) 0/0 ON CENTER COL COLUMN OD OUTSIDEDIAMETER COMP COMPRESS(ED)OTHERWISE. (ION) or OUTSIDE FACE CONC CONCRETE 010 OWNER FURNISHED CONTRACTOR INSTAIIID CONN CONNECTION OF01 OWNER FURNSHED OWNER INSTATED CONST CONSTRUCTION OPG OPENING COM CONTINUOUS, CONTINUE OPP OPPOSITE. OPPOSITE HAND COR IOM PARALLEL CT CERAMIC TILE RCC PRECAST CONCRETE CTSK COUNTERSUNK PCF POUNDS PER CUBIC FOOT CY CUBE YARD(S) PERF PERFORATE(D) IL, DA DIAMETER PERIM PERIMETER DBL DOUBLE PO PATTERN GLASS 00501 DEMOLISH, DEMOLITION PL PLATE DEP DEPRESSED PLANT PLASTICLAMINATE DIA DIAMETER PLYWD PLYWOOD DAG DIAGONAL PNL PANE DIM DIMENOON PRES1 PRE SII¢SS(ED) DL DEAD LOAD PRF PREFORMED DN DOWN PSI POUNDS PER SQUARE FOOT DS DOWNSPOUT P51 POUNDS PER SQUARE INCH DWG DRAWING PT POINT, PAINT PVC POLYVINYL CHLORIDE E EAST (000RDNATE) EA EACH R RADIUS (CURVATURE) EB EXPANSION BOLT R RISER EF EACH FACE RB RESILIENT BASE EJ EXPANSION ,ENT REF REFERENCE, REFER TO EL ELEVATION REINF REINFORCE(D) (INC) EILY ELEVATION REO REQUIRE(D) (INC) 00 EQUALREV REVERSE, REV510N(5). REVISED EIV EACH WAY RH RIGHT HMD EX EXISTING RO ROUGH OPENING EEXP EXPOSED XT EXTERIER 5 SOUTH (COORDINATE) SECT SECTION FAS FASTEN(ER) SF SQUARE FEET FE FIRE EXTINGUISHER SHT SHEET FEC FIRE EXTINGUISHER CABINET SIN SIMILAR22. FF FINISHED CEILING SO SQUARE FF FACTORY FINISH SS SOLID SURFACING FF FINISHED FLOOR SST STAINLESS STEEL FOR FINISH GRADE Si STRUCTURAL TEE FH FIRE HYDRANT STD STANDARD FIN FTNISH(ED) SR STEEL END FOUNDATION STR STRUCTURAL FOC FACE OF CONCRETE SYR SYMUETRY,SYMUETRICAL FOF FACE OF FINISH SYS SYSTEM T&B TOP AND BOTTOM FDIC FURNISHED BY OWNER/ T&G TONGUE AND GROOVE INSTALLED BY CONDUCTOR TEMP TEMPORARY FO FINISHED OPENING THK THICK(NESS) FRO FOR REFERENCE ONLY TOC TOP OF CURB FT FOOT TOC TOP OF CONCRETE FTG FOOTINGTOLTOLERANCE FUT FUTURE 15$ STP OF STEEL N FIELD VERIFY 15 STRUCTURAL TUBE GA GAGE lYP mica. GREG GLASS FIBER REINFORCED GYPSUM GM GALVANIZED UBC UNIFORM BUILDING CODE GC GENERAL CONTRACTOR UL UNDERWRITERS' LABEL GI GALVANIZED IRON 0NO UNLESS NOTED OTHERWISE UPR UPPER CR GRADE GT GROUT VB VAPOR BARRIER ORB GYPSUM WALL BOARD VC VINYL COMP. TILE VERT AREAL HOAR HARDENER NF VERIFY IN FIELDRCP'S, H0WR081D HARDWOOD W WEST (COORGNATE) HOwR HARDWARE W WIDE FLANGE HG HIGH GRADE W WIDTH, WIDE HM HOLLOW METAL WC WATER CLOSET HOE HORIZONTAL WD WOOD HS HIGH STRENGTH W/0 WITHOUT HT HEIGHTW/0 WELDED WIRE FABRIC INC INTERNATIONAL ID INSIDENSIDE DIAMETER BLDG. CODE NOTE: REFER TO THE COLOR AND DLR ID INSIDE DIMENSION MATERIAL SCHEDULE FOR ADDITIONAL t,,„•,,,,,. 1„s,,,,�,,,,Y FINISH AND IF INSIDE FACE DESIGNATIONS ABBREVIATIONS 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. Group r1,,,..,s ,m,..., OBTAIN & POST REQUIRED CONSTRUCTION PERMITS FROM THE CITY OF KENT PRIOR TO COMMENCING CONSTRUCTION. VERIFY ALL EXISTING CONDm0N5 AND NOTIFY THE BOEING PROJECT CONSTRUCTION MANAGER SHOULD CONDITIONS DIFFER FROM DESIGN DOCUMENTS. THE SCOPE OF WORK INCLUDES AU. WORK WEAN THE CURRENT REVISIONCI0UD(S ON EACH SHEET. IF THERE IS NO CLOUD ON A SHEET THE ENTIRE SHEET IS W THE SCOPE OF WORK. INFORMATION OR WORK (WHETHER CLOUDED OR NOT) REFERRED TO FROM WITHIN A CLOUD INCLUDED IN THE SCOPE OF WORK (I.E. - A SECTION OR DETAIL SYMBOL THAT UES WITHIN CLOUD ON A PLAN NEW SHEET IS INCLUDED IN THE SCOPE EVEN WHEN THE ACTUAL SECTION DETAIL DRAWN ON INC DETAIL. SHEET IS NOT CLOUDED.) KEEP ALL MEAS UNDER CONSTRUCTION CLEAR OF DEBRIS CAUSED BY THIS SCOPE OF WORK. STORE CONSTRUCTION MATERIALS AND EQUIPMENT 1N AREA DESIGNATED BY THE BOEING PROJECT CONSTRUCTION MANAGER. VERIFY DIMENSIONS AND CONDITIONS SHOWN ON THE DRAWINGS AND ENSURE THAT THE JOINING OF THE WORK OF VARIOUS TRADES MEETS APPROPRIATELY. BRING DISCREPANCIES ON THE DRAWINGS OR IN SPECIFICATIONS TO THE ATTENTION OF THE BOEING PROJECT CONSTRUCTION MANAGER IMMEDIATELY UPON DISCOVERY. THE CONTRACTOR SHALL ADVISE BOEING. SUMMARIZE THE SITUATION MD PROVIDE RECOMMENDATIONS TO RESOLVING POTENTIAL CONFLICTS PRIOR SUBMITTING ANY REQUESTS FOR INFORMATION (RE0s). CONFORM ALL WORK TO APPLICABLE CODES. REGULATIONS AND INDUSTRY STANDARDS. COMPLY W1111 THE BOEING PROJECT CONSTRUCTION MANAGER FOR CONSTRUCTION AREA AND SECURITY REGULATIONS. PROVIDE, AS IF DRANK IN FULL, REPETITIVE FEATURES NOT FULLY SHOWN OR NOTED ON THE DRAWINGS. DIMENSIONS ON DRAWINGS ME TAKEN TO THE FACE OF MASONRY AND/OR CONCRETE WALLS, METAL STUDS, AND TO THE CENTERLINE OF COLUMNS, UNLESS OTHERWISE NOTED. DOOR OPENINGS ARE 6- FROM ADJACENT WALLS OR CENTERED IN ROOM WALL, UNLESS DIMENSIONED OTHERWISE. PARTITIONS 5551 RUN FIAT HEIGHT, FROM FLOOR TO FLOOR ABOVE UNLESS SHOWN OR NOTED PLANS WHICH APPEAR AS -BACKGROUNDS- ON CML, STRUCTURAL PLUMBING, HVAC, ELECTRICAL DRAWINGS ETC., ARE FOR THE PURPOSE ONLY OF ILLUSTRATING GENERAL PLM CONFIGURATION. SUCH BACKGROUNDS SHALL NOT BE USED FOR PORTIONS OF THE WORK OTHER TWIN THAT PERTSMNG TO THE TIRE OF EACH SHEET. REFER TO THE APPROPRIATE SHEET FOR EACH SPECIFIC PORTION OF THE WORK. COORDINATE THE WORK OF ALL TRADES. REFER TO ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS IN DETAIL FOR COORDINATION OF SPECIFIC TRADE REQUIREMENTS. COORDINATE ALL ROUGH -IN REQUIREMENTS FOR EQUIPMENT FURNISHED BY CONTRACTOR OR OTHERS FOR THIS PROJECT. PROVIDE MANUFACTURERS INSTALLATION INSTRUCTIONS TO THE BOEING PROJECT CONSTRUCTION MANAGER WHENEVER SUCH INSTRUCTIONS ARE REFERENCED IN THE CONSTRUCTION NOTES. CONTRACTOR SHALL COORDINATE WITHTHE BOEING PROJECT CONSTRUCTION MANAGER FOR STAGING MEAS WHERE CONTRACTOR CLAY STORE SALVAGED MATERIALS TO BE REUSED IN LATER PMTS OF THIS PROJECT AND WHERE MATERIALS TO BE STAGED BY BOEING ME TO BE LOCATED. SYMBOLS SHOWN ON MATERIALS UST ARE NOT ALWAYS USED IN DRAWINGS. VERIFY EXISTING MATERIAL AND SEE CONSTRUCTION NOTES FOR MATERIAL CALL0U15. WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED AS A RESULT OF DEMOLITION OR PERFORMANCE OF NEW WORK, THE CONTRACTOR IS TO PATCH M0 REPAIR THE EXISTING TO MATCH ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BEAR UNES SUCH AS CORNERS, CEILING ONES, TOP OF BASE, CHANGE IN MATERIAL OR ALL RECESSES LOCATED w1MIN FIRE RATED PARTITIONS SHALL BE CONSTRUCTED TO MAINTAIN REQUIRED FIRE PARK OF THE PARTITION. ARCHITECTURAL REFLECTED CERING PLANS INDICATE THE FINAL LOCATIONS OF MECHANICAL ELECTRICAL COMPONENTS. SEE THE REFLECTED CEILING PLANS FOR LOCATIONS OF ITEMS CEILING; SEE DSCIPLINE SHEETS FOR ALL INFORMATION ABOUT THE MECHANICAL AND ELECTRICAL COMPONENTS INDICATED ON ARCHNECTURAL REFLECTED CLUNG PLANS. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING FIRE AUTHORITIES, BETWEEN FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS AND ALL PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL- AND OTHER ITEMS. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS FOR CUTTING AND PATCHING WORK WITHIN THE BUILDING, BEYOND THE WATTS OF THE ARCHITECTURAL DRAWINGS. AT METAL STUD PARTITIONS. STUDS ARE TO EXTEND FROM FLOOR TO FLOOR U.N.O.. WHERE DO SO. DUE TO INTERFERENCE WITH NEW OR EXISTING DUCTS, PIPING, ETC., PROVIDE BRACING TO STRUCTURE MOVE TO PROVIDE FOR EQUIVALENT SUPPORT OF PMIRION; SUBMIT EQUIVALENT SUPPORT METHOD TO ARCHITECT FOR REVIEW. ALL FRE RATED PARTMONS SHALL CONSTRUCTED TO MAINTAIN THEIR RATING FROM FLOOR TO UNDERSIDE OF STRUCTURE ABOVE, U.N.O. PROVIDE ACCESS DOORS AS INDICATED DR A5 NECESSARY AND VERIFY WITH MECHANICAL AND ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS REQUIRED BY THEIR WORK. ACCESS MUST BE PROVIDED FOR ALL CONCEALED VALVES. DAMPER CONTROLS. FIRE DAMPER LINKAGES, CONCEALED JUNCTION 80005, AND ELECTRICAL DEVICES OR ACCESSOR ES. LOCATIONS AND Of EXPOSED ACCESS DOORS SHALL BE SUBMITTED TO THE ARCHITECT FOR REVIEW PRIOR INSTALLATION OF THE MECHANICAL AND ELECTRICAL EQUIPMENT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SAFETY IN THE AREA OF WORK IN ACCORDANCE WITH ALL SAFER' CODES, REGUMRONS AND BOEING REQUIREMENTS. THE CONTRACTOR SHALL RETAIN A FIRE PROTECTION ENGINEER LICENSED IN THE STATE OF WASHINGTON TO DETERMINE/DESIGN THE MODIFIED FIRE SPRINKLER SYSTEM LAYOUT WTIMN AREA OF WORK. SAID ENGINEER SHALL STAMP, SEM AND CERTIFY THAT HIS/HER DESIGN IS COMPLIANCE W/011 APPLICABLE CODES AND REGULATIONS. CONTRACTOR SHALL COORDINATE NECESSARY M0DIFICA1TONS AS A RESULT OF SAID ENGINEER'S DESIGN. THE CONTRACTOR SHALL INSURE THAT THE ELEVATOR CAR, EOUIPMENT ROOM, EQUIPMENT LAYOUT AND HYDRAULIC ELECTRICAL ROUTING FULLY MEETS STATE OF WASHINGTON CODES AND / COMPLIANCE. FULLY COORDINATE WITH ARCHITECT PRIOR TO FABRICATION AND INSTALLATION. AT LOCATIONS WHERE STRUCTURE. PIPING. DUCTWORK, CABLETRAY, OR CONDUIT PENETRATES WALLS MD ARE EXPOSED TO VIEW. CONTRACTOR SHALL COPE AS CLOSELY AS POSSIBLE TO MEMBER AND INSTALL CONTINUOUS CAULKING AROUND MEMBER AND PAINT OR PROVIDE ESCUTCHEONS MATCHING WALL COLOR AT PENETRATIONS. FOR CONSISTENCY ALL CONSTRUCTION NOTES ('FUG NOTES") FOR EACH GROUP: PLAN AND ME SHOWN IN THEIR ENTIRETY. ALL CONSTRUCTION NOTES MAY NOT BE REFERENCED EERYTTY FRAME TYPES ARE TYPICALLY DRAWN LOOKING FROM THE OUTSIDE OR KORNER SIDE 15 A OR TO BY SIMILAR, AND IN THE ALL THEY BE SIZES TO THE IN All THE n ON Il E C E I V OF TU 0. NOV 1 2 , CE SECTION/DETAIL DESIGNATION BUILDING, WALL SECTIONS n -MM -MM -n-. 8=nn-u-u- EMIR, flEggEMEE STONE. X r0 AND DETAIL REFERENCES SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM %" ii•" % BRICK. {Tf }} i}7}j CERAMIC / INTERIOR ELEVATION REFERENCE • AX X B SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM N i REFERENCE TO DETAIL/ENLARGED CONCRETE BATT, DIRT, UNDISTURBED RICO BRONZE, COPPER STEEL. IRON SEND, CEMENT, GYPSUu FINISH ROUGH CONTINUOUS INTERRUPTED SMALL SCALE LARGE SCALE TYPE: CONCRETE TYPE: STEEL TYPE: WOOD TYPE: EXISTING TYPE REMOVAL TYPE: PARTITION TYPE: GLASS COMPLIANCE ���� 2 of T.�.1T BIIAIIUIUUht1!II�1�iL INSULATION: 14.11:ACW0C4AN EARTH, INSULATION: IX X 8 L DETAIL DESIGNATION Ml r//,‘ // ,VA ALUMINUM �•"- - i BRASS, Ia. fy�TMl✓ SHEET NUMBER WHERE DETAILED OF SAME A5 SHEET REFERENCED V� SECTION/DETAIL DESIGNATION 1. s"/// . .,,A METAL, I - I PLASTER: )3(XX`XXXXX SHEET NUMBER WHERE DETAILED SHEET NUMBER REFERENCED FROM N NORTH ARROW ELEVATION DAVM (- - I PLASTER: 1 1 1 W000: C WOOD: OR SPOT ELEVATION (XIX) CEILING HEIGHT A.F.F. XXXXXX R00M NAME 11/000: WOOD: ® PLYWOOD: XXXX I ROOM NUMBER MSE:'.:'.:: i3MS, 11110001): ® DOOR NUMBER �� (\ ` _ GRID/GRID BUBBLE AND CENTERLINE ITEMS TO BE REMOVED CONSTRUCTION -FLAG- NOTE FOR CONSTRUCTION DIRECTIVE GENERAL -BOAT- NOTE FOR SPECIFIC OR EXISTING HISTORICAL1 INFORMATION ( J( WINDOW FRA1AE TYPE > \\ X/� PARTDION/WALL TYPE • I��F I END WALL GUARD --- ���111 p CORNER GUARD I E ',/../..... 'X' '. %I WALL 1 ''.. WALL ® WALL 1WAIL WALL 1 I WALL u n WALL REVIEWS L. • ODE APPR ) , �/ 1` NOV ' r( • Citv 1• BUILDINNIGHT ( CPT -1) FINISH DESIGNATION REVISION CLOUD WITH REVISION 111115 'BEAK' A VCT CPT FLOOR MATT iRANSTTION LEO FIRE EXTINGUISHER ['ICI] FIRE EXTINGUISHER & CABINETMJ M�}y FyI Q e SUPPLY AIR DIFFUSER •. .•••-,•Ilk. n RETURN AIR GRILLE FLOURESCENT LIGHT FIXTURE R 6 (PENDANT D I FLOL'RESCENT LIGHT FIXTURE (PENDANT FLOURESCENT UGHi FIXTURE ON p LIGHT (NL) CRCUH O RECESSED OR PENDANT LIGHTING R RECESSED OR PENDANT LIGHTING • FLOURESCENT UGHT FIXTURE ON NIGHT UGHT (NL) CIRCUIT =OCT WALL SCONCE 1 6 NMI SCONCE 2 H EXIT SIGN (WALL MUNIT)UNI( 1-631 EXIT SIGN (WALL MOUNT) 90% SUBMITTAL ISSUED FOR PERMIT R M I T PERMIT STA REVISION S APPROVED DALE MIA REV610N B1. ARMED OAll I I B�E,�” T ® 5188 ACCEPTABILITY 155 DESIGN AND/OR SPECIFICATION 5 APPROVED PRA 14 DLR CROUP DATE 04.04.08 5UBTRLE KEY SHEET CURRENT REVISION SYMBOL JH19760 ORIG DATE 10.22.13 ORIG CDC RELOCATION - WIRE SHOP RELOCATION J.19760 DER GROUP ECA 10.22.13 REGISTERED ARCHITECT LD • • KRUSE T_ DF AS 1145005 LHE D. RED N00 04.04.08 SHEETG1 APPROV DB DEP .DA £WEERT LE WIRE SHOP RELOCATION TO 2-81ii 2-81 BUILDING ARCHITECTURAL MASTER PLANT2, WA CHECKED APPROVED JOB N0. 19760 COMP N0. APPROVED 0 WG NO, 2-81-01 ED KWILA X013 1\1TER i I\ D I- X 01- D RAW \ G S ISSUE LEGEND INCLUDED SET I DRAWING NO. SHEET NO. DRAWING SUBTITLE REV DATE INCLUDED INS SET DRAWING NO. SHEET NO. 1 DRAWING SUBTITLE REV DATE INCLUDEDI IN SET I DRAWING NO. SHEET NO. DRAWING SUBTITLE REV DATE NOT YET ISSUED 1IN _ _ PREVIOUSLY ISSUED FOR CONSTRUCTION GENERAL ARCHITECTURAL o PREVIOUSLY ISSUED, BUT RE IUSIN THIS 13 NOT IN O SE • 02 -81 -GO GO VICINITY MAP, LEGAL DESCRIPTION AND CODE SUMMARY ORIG 10-22-13 • 02-81-A3 A3 COMPOSITE FIRST FLOOR PLAN A 10-22-13 • 02-81-M1M456 M1M456 MEZZANINE DUCTWORK A 10-22-13 • INCLUDED IN THIS ISSUE • 02-81-G1 G1 KEY SHEET ORIG 10-22-13 • 02-81-G2 G2 INDEX ORIG 10-22-13 • 02-81-1Al2 1Al2 FLOOR PLAN D 10-22-13 • 02-81-M506 M506 HVAC DETAILS A 10-22-13 • 02-81-1A13 1A13 FLOOR PLAN D 10-22-13 • 02-81-M513 M513 PLUMBING DETAILS A 10-22-13 PREL PRELIMINARY ISSUE FOR REVIEW OR • 02-81-M1Al2 M1Al2 MEZZANINE LAYOUT PLAN A 10-22-13 • 02-81-UGM455 UGM455 ENLARGED PLUMBING PLAN B 10-22-13 INFORMATION ONLY ARCHITECTURAL REMOVALi • 02-81-1A282 1A282 REFLECTED NOT FOR CONSTRUCTION • 02-81-1Al2R 1Al2R FLOOR PLAN D 10-22-13 CEILING PLAN ; I A 10-22-13 FOR REFERENCE • 02-81-1A13R 1A13R FLOOR PLAN D 10-22-13 • 02-81-1L12 1L12 LAYOUT PLAN j ORIG 10-22-13 ONLY ORIG ORIGINAL ISSUE • 02-81-1L13 1L13 LAYOUT PLAN I ORIG 10-22-13 02 -81 -MO MO LEGEND - 11-12-99 FOR PERMIT, BID, • 02-81-M1Al2R M1Al2R MEZZANINE LAYOUT PLAN A 10-22-13 PROCUREMENT OR CONSTRUCTION • 02-81-A60 A60 EXTERIOR ELEVATIONS A 10-22-13 • 02-81-1A282R 1A282R REFLECTED CEILING PLAN A 10-22-13 02-81-A351 A DRAWING REVISION - • 02-81-1L12R 1L12R LAYOUT PLAN ORIG 10-22-13 • A351 DOOR SCHEDULE ORIG 10-22-13 ELECTRICAL SEE SPECIFIC DRAWING • 02-81-1L13R 1L13R LAYOUT PLAN ORIG 10-22-13 • 02-81-A453 A453 STAIR NO 2 PLAN FOR NATURE OF • 02-81-A458 A458 AND SECTION FINISH PLAN A 10-22-13 • 02 -81 -ED EO ELECTRICAL LEGEND A 10-22-13 REVISION • 093-818-2L1OR 2L10R LAYOUT PLAN ORIG 10-22-13 • 02-81-A459 A459 FINISH PLAN ORIG A 10-22-13 10-22-13 • 02-81-1E2 1E2 480Y/277 VOLT POWER A 10-22-13 • 093-818-2L11R 2L11R LAYOUT PLAN ORIG 10-22-13 • 02-81-1E3 1E3 208Y/120 VOLT POWER A 10-22-13 FOR REFERENCE ONLY 02-81-A350 A350 WALL TYPES - 11-12-99 • 2-YD-V50E4 E4 ONE -LINE DIAGRAM - VAULT 50 B 10-22-13 02-81-A501 A501 DETAILS - 11-12-99 • 02-81-1E12 1E12 LIGHTING C 10-22-13 02-81-A504 A504 DETAILS - 11-12-99 STRUCTURAL REMOVAL 02-81-A507 A507 DETAILS - 11-12-99 • 02-81-1E62 1E62 208Y/120 VOLT POWER C 10-22-13 • 02-81-RFE110 RFE110 ROOF 480/277 VOLT POWER B 10-22-13 • 02-81-1E112 1E112 480Y/277 VOLT POWER A 10-22-13 • 02-81-1E161 1E161 400 HZ 200Y/115 VOLT POWER A 10-22-13 STRUCTURAL • 02-81-1E162 1E162 400 HZ 200Y/115 VOLT POWER ORIG 10-22-13 MECHANICAL REMOVAL • 02-81-S1A S1A GENERAL STRUCTURAL NOTES ORIG 10-22-13 • 02-81-1E212 1E212 CMCS PLAN D 10-22-13 • 02-81-1M12R 1M12R DUCTWORK REMOVAL C 10-22-13 • 02-81-1S62 1S62 PARTIAL FIRST FLOOR SLAB PLAN A 10-22-13 • 02-81-1E262 1E262 SMOKE DECTECTOR / ADT A 10-22-13 • 02-81-1M11OR 1M11OR PLUMBING REMOVAL A 10-22-13 • 02-81-S412 S412 STRUCTURAL DETAILS ORIG 10-22-13 • 02-81-1E362 1E362 TELECOMMUNICATION B 10-22-13 REVIEWED • 02-81-1M112R 1M112R PLUMBING REMOVAL C 10-22-13 FOR 1 _ • 02-81-E500 E500 LIGHTING FIXTURE SCHEDULE B 10-22-13 CODE COMPLIANCE • 02-81-1M262R 1M262R FIRE PROTECTION REMOVAL B 10-22-13 • 02-81-E501 E501 ELECTRICAL PARTIAL PLANS A 10-22-13 APPROVED • 02-81-M311R M311R HVAC FLOW DIAGRAM REMOVAL A 10-22-13 • 02-81-M331R M331R CMCS MISCELLANEOUS SYSTEM CONTROLS A 10-22-13 FOR REFERENCE ONLY NOV 02-81-E510 E510 COMMUNICATION DETAILS - 11-12-99 2 7 2013 • 02-81-M454R M454R CAFETERIA & KITCHEN PLUMBING REMOVAL C 10-22-13 02-81-E511 E511 FIRE ALARM RISER DIAGRAM - 11-12-99 MECHANICAL 02-81-E512 E512 FIRE ALARM DETAILS - 11-12-99 • 02-81-M1M456R M1M456R MEZZANINE DUCTWORK REMOVAL A 10-22-13 02-81-E513 E513 CONTROL SCHEMATICS - 11-12-99 • 02-81-M1A M1A EQUIPMENT SCHEDULE B 10-22-13 02-81-SK33G101713 SK33G 400 HZ PERMISSIVE & STINGER RECEPT - 11-12-99 City of Tukwila • 02-81-M515R M515R FIRE PROTECTION DETAILS A 10-22-13 • 02-81-M1B M1B EQUIPMENT SCHEDULE A 10-22-13 02-81-2E115 2E115 480Y/277 VOLT POWER 11-12-99 • 02-81-M1C MIC EQUIPMENT SCHEDULE A 10-22-13 BUILDING DIVISION • 02-81-UGM455R UGM455R PARTIAL PLUMBING PLAN REMOVAL B 10-22-13 • 02-81-M2 M2 GENERAL NOTES A 10-22-13 • 02-81-1M12 1M12 DUCTWORK C 10-22-13 • 02-81-1M62 1M62 HVAC PIPING A 10-22-13 ELECTRICAL REMOVAL • 02-81-1M110 1M110 PLUMBING A 10-22-13 • 02-81-1E2R 1E2R 408/277 VOLT POWER A 10-22-13 • 02-81-1M111 1M111 PLUMBING B 10-22-13 • 02-81-1E3R 1E3R 208/120 VOLT POWER A 10-22-13 • 02-81-1M112 1M112 PLUMBING C 10-22-13 • 02-81-1E12R 1E12R LIGHTING C 10-22-13 • 02-81-1E62R 1E62R 208Y/120 VOLT POWER C 10-22-13 • 02-81-1M262 1M262 FIRE PROTECTION B 10-22-13 • 02-81-1E112R 1E112R 480Y/277 VOLT POWER A 10-22-13 • 02-81-1M263 1M263 FIRE PROTECTION B 10-22-13 • 02-81-1E212R 1E212R CMCS PLAN D 10-22-13 • 02-81-1E262R 1E262R SMOKE DECTECTOR / ADT A 10-22-13 • 02-81-RFM3 RFM3 DUCTWORK AND HVAC PIPING B 10-22-13 • 02-81-1E362R 1E362R TELECOMMUNICATIONS 0 10-22-13 G 02-81-M310 M310 HVAC CONTROL SEQUENCES B 10-22-13 • 02-81-M311 M311 HVAC FLOW DIAGRAM A 10-22-13 • 02-81-M319 M319 CHILLED WATER PIPING DIAGRAM A 10-22-13 • 02-81-M321 M321 FIRST FLOOR HEATING WATER PIPING DIAGRAM A 10-22-13 RECEIVED • 02-81-M327 M327 AHU-6 P & ID A 10-22-13 DLR Group CITY OF TUKWILA • 02-81-M330 M330 TERMINAL EQUIP P & ID A 10-22-13 • 02-81-M454 M454 ENLARGED PLUMBING PLAN C 10-22-13 NOV 2 2013 90% SUBMITTAL ISSUED FOR PERMIT PERMIT CENTER $YM fiVNON BY APPROVED MTE BYM REVISION BY ApPRDyTO DATE ACCEPTABILITY DRAWN DATE SUE.. CURRENT REVISION STYROL DATE (RIG CDC RELOCATION - WIRE SHOP RELOCATION J}19760 OLR CROUP ECA 10.22.13 51yy ARCHITECT' THIS DESIGN AND/OR E. ANGULO CHIC KED 09.05.13 INDEX ��197so I 1D 2213 off sPECIF1CAnON Is APPROVED E. ANGULO ENGINEER 09.05.13 SHEET 0 ® APPROVED BY DEPT. DATEWIRE TITLE SHOP RELOCATION TO 2 81 A 2 g)LardirAw,Arc1 'CHECKED =OT AS IT1 „APPROVED BUILDING 2-81 JOB NO. 19760 COMP NO. s APPROVED ARCHITECTURAL MASTER PLANT2, WA DWG NO. 2-81-G2 AIR HANDLERS MARK NO. SERVICE/LOCATION SUPPLY FAN RETURN FAN FILTERS I CHILLED WATER COIL TOTAL BTUH SENSIBLE BTUH CFM FUTURE CFM PRESENT 1OIAL SP IN WINTER ESP IN. WTR FAN RPM BHP MOTOR HP FAN TYPE DRIVE CFM ESP N. WTR FAN RPM BHP MOTOR HP FAN TYPE DRIVE % EFFICIENCY' VEL CI 141AX5 EAT DB��ApT WB DEC FIDEG F LAT DR DEGIF AT WB DEC F EWF DEC F LWT DEC F CAPACITY MBH FACE VELOCITY GPM CONTROL VALVE DELTA P WPD FT WER APD FT WTR FPI ROWS PRE I FINAL F AHU-1 2ND FLR NORTH/ROOF 43,450 39,500 5.25 2.15 (2)1/10 120 60 PLUG BELT 39,035 1.0 PLTITUS ENUM 2-PIPEE FAN COIL 160 15 PLUG BELT 30 85 500 75.5 61.1 52:9 51.5 45 55 1084 500 210 5 PSIG 6.8 0.70 8 6 AHU-2 2ND FLR SOUTH/ROOF 46,815 42,560 4.25 1.12 34,000 PROVIDED BY BOEING 60 PLUG BELT 43,470 0.75 - - 15 PLUG BELT 30 85 500 75.1 61.0 5219 51.5 45 55 1019 500 204 5 PSIG 7 6 0.78 8 6 AHU-3 2ND FLR CORE/ROOF 23,925 21,750 4.50 1.27 40 PLUG BELT 20,515 1.0 7.5 PLUG BELT 30 85 500 77.1 62.3 52.9 51.5 45 55 673 500 135 5 PSIG 39 0.68 8 6 AH -4 T R OF 57,570 52,3 4.50 1.46 75 PLUG BELT 47,330 1.75 15 PLUG BELT 30 85 500 75.2 61.0 52 9 51.5 45 55 1274 500 255 5 PSIG 8 4 0.75 8 6 > AHU-5 1ST FLOOR SE/MEZZ. 8 5 8,385 4.00 3.46 1944 7.73 10 PLUG BELT 7,440 0.5 598 1.03 3 PLUG BELT 30 85 500 81.2 66.3 53.4 52.8 45 55 283 500 56 5 PSIG 4 9 0.61 8 6 o. AHU-6 1ST FLOOR SE/MEZZ. 8,440 7,350 4 1150 4.3 7.5 CENT BELT - - - 30 500 85 55 45 55 441 500 88 5 PSIG 3 8 0.74 8 6 NOTES: 1. REPLACE EXISTING MOTOR AT AHU-6 WITH NEW INVERTER DUTY MOTOR OF EQUAL S ZE, HORSEPOWER AND RPTA, COGPATI BLE WFTTi VFD OPERATION. FAN COIL SCHEDULE MARK NUMBER LOCATION SERVICE CFM ESP IN W.G. MIN OA CFM TOTAL BTUH SENSIBLE BTUH COOLING COIL (QTY)HP MOTOR VOLTAGE FILTERS I REMARKS EDB DEC F EWB DEG F LOB DEG F LWB DEC F EWE DEC F LWTWpp DEC F GPM WG ROWS MEDIA TYPE EFF MAX MAX DECTAP IN W.G. % FPM CLEAN DIRTY ,FCU -1-01 E.1/4.0 ELECTRICAL ROOM 850 0.2 0 33,300 23,400 78 65 55 53 45 55 6.6 6.3 4 (2)1/10 120 DISPOSABLE 30 400WITH .25 NOTE 1 PLTITUS ENUM 2-PIPEE FAN COIL CABINET UNIT HEATERS MARK NO. SERVICE FAN HOT WATER HEATING MANUFACTURER/MODEL REMARKS OUTSIDE MINIMUM RETURN MAXIMUM CFM MOTOR HP DRIVE COIL CAPACITY MBH EWE DEG F LWT DEG F CPM MAX WPD FT 36,305 EF -01 CUH-01 LOBBY VESTIBULE 50 1/30 DIRECT 2.76 180 160 0.28 0.1 INTERNATIONAL FSY-C2 NOTE 1 CUH-02 NORTHWEST VESTIBULE 50 1/30 DIRECT 2.76 180 160 0.28 0.1 INTERNATIONAL FSY-C2 NOTE 1 CUH-03 NORTHEAST VESTIBULE 50 1/30 DIRECT 2.70 180 160 0.28 0.1 INTERNATIONAL FSY-C2 NOTE 1 NOTES: 1. ALL FAN MOTORS ARE: 120 VOLTS, 1 -PHASE, 60Hz. EXHAUST FANS MARK NO. SERVICE LOCATION FAN TYPMANUFAC URER/MODEL REMARKS OUTSIDE MINIMUM RETURN MAXIMUM RETURN MINIMUM CFM E.S.P. in W.C. FAN RPM BHP MOTOR HP DRIVE 3,195 36,305 EF -01 T(aT�¢NB�1 ORS ROOF 4880 1.0 625 0.65 3/4 BELT ROOF EXHAUSTER . , 39,520 EF- AHU-6 RELIEF/MEZZ OOF 7350 21,750 65 .39 7.5 E RELIEF AIR FAN FOR AHU-6 GRFFNHFCK CURF '160 HP AHU-4 > EF -08 NOT USED 52,335 9,310 43,025 8,080 43,025 0 AH - :,3: 00. > EF -09 NOT USED 7 E: 7,1:E ,08 160 AHU-6 7,350 2,250 7,350 2,250 EF -10 L IC1 H• 1ST FLR CEILING 500 3.18 - - 1 2 / DIRECT D .�0 EXTRACTOR 87 0. 0 •T EF -12 TRANDUCER & CALIBRATION FAC. ROOF 335 4.0 - - 1/3 BELT 34,000 PROVIDED BY BOEING EF -13 ELECTRICAL SHOP 1ST FLR CEILING 500 4.08 - - 1.0 DIRECT NEDERMAN 5000 EXTRACTOR 7 FOOT EXTRACTOR ARM EF -14 HYDRAULIC RM WALL 100 0.125 1500 - 0.1 DIRECT CENTRIFUGAL FAN ZEPHYRS. MODEL Z3H PROVIDE 277/115V TRANSFORMER EF -15 DATA RMS & ELECT RMS ROOF 2150 0.25 634 0.20 1/4 BELT ROOF EXHAUSTER PENN -VENTILATOR, DX169 NOTE 1 NOTES: 1 9 2. REPLACE EXISTING MOTOR AT EF -05 WITH NEW INVERTER DUTY MOTOR OF EQUAL SIZE, HORSEPOWER AND RPM, COMPATIBLE WITH VFD OPERATION. :_IJ FOR )MPLIANCE ROVED 7 2013 '; Tukwila )(BUT: lIVISION CONSTRUCTION NOTES EXISTING EQUIPMENT TO BE REBALANCED TO AIRFLOWS INDICATED IN THIS SCHEDULE. PROVIDE NEW EOUIPMENT AS SCHEDULED. PRESENT DESIGN AIRFLOWS MARK NO. CFM WEIGHT SUPPLY MAXIMUM SUPPLY MINIMUM OUTSIDE MAXIMUM OUTSIDE MINIMUM RETURN MAXIMUM RETURN MINIMUM RELIEF MAXIMUM RELIEF MINIMUM AHU-1 39,500 15,800 39,500 3,195 36,305 12,805 36,305 0 AHU-2 42,560 17,025 42,560 3,040 39,520 13,385 39,520 0 AHU-3 21,750 8,700 21,750 3,100 18,650 6,800 18,650 0 AHU-4 62,335 17,400 52,335 9,310 43,025 8,080 43,025 0 AH - :,3: 00. : 85 ors 7 E: 7,1:E ,08 160 AHU-6 7,350 2,250 7,350 2,250 5,100 0 7,350 2,250 a AIR HANDLERS MARK NO. HOT WATER HEATING COIL WEIGHT MANUFACTURER REMARKS REMARKS EAT DEC F LAT DEC F EWE DEC F LWT DEC F CAPACITY MBH FACE VELOCITY GPM CONTROL VALVE DELTA P WPD FT WTR APD FT WTR FPI ROWS LBS. UH -03 INSTRUMENTATION VAN STAGING AHU-1 56 87 180 160 290.2 500 29.0 5 PSIG 5.4 0.13 6 2 32,500 TEMTROL NOTE 1, 2 AHU-2 56 87 180 160 287.6 500 28.8 5 PSIG 4.3 0.13 6 2 32,500 TEMTROL NOTE 1, 2 AHU-3 56 87 180 160 205.7 500 20.6 5 PSIG 2.5 0.11 6 2 27,000 TEMTROL NOTE 1, 2 AHU-4 56 87 180 160 193.3 500 19.3 5 PSIG 4.8 0.13 6 2 34,000 TEMTROL NOTE 1, 2 AHU-5 56 87 180 160 246.3 500 15.0 5 PSIG 1.6 0.11 6 2 10,000 TEMTROL NOTE 1 AHU-6 21 59 180 160 292.2 500 30.0 5 PSIG 1.1 0.11 6 2 13,000 TEMTROL NOTE 1 NOTES: 1. ALL FAN MOTORS ARE: 1760 RPM, 480 VOLTS, 3-PHASE, 60Hz. 2. AHU 1, 2, 3 & 4- SUPPLY AND RETURN AIRFLOWS INCLUDE 10% FUTURE CAPACITY. UNIT HEATERS MARK NO. SERVICE FAN HOT WATER HEATING MANUFACTURER/MODEL REMARKS RPM HP CFM RPM MOTOR HP DRIVE COIL CAPACITY MBH E DEG F LWT DEG F GPM MAX WPD FT SUMP PUMP 10 UH -03 INSTRUMENTATION VAN STAGING 1340 1625 1/8 DIRECT 59.5 180 160 6.3 1.4 MODINE, MODEL HS -86 NOTE 1, 2 UH -04 INSTRUMENTATION VAN STAGING 1340 1625 1/8 DIRECT 59.5 180 160 6.3 1.4 MODINE, MODEL HS -86 NOTE 1, 2 UH -05 INSTRUMENTATION VAN STAGING 1340 1625 1/8 DIRECT 59.5 180 160 6.3 1.4 MODINE, MODEL 1-15-86 NOTE 1, 2 UH -06 NOT USED UH -07 SHIPPING AND RECEIVING 1120 1550 1/12 DIRECT 42.3 180 160 4.7 0.8 MODINE, MODEL HS -63 NOTE 1, 2 NOTES: 1 UNIT HEATERS WERE SIZED BASED ON MODINE, MODEL HS -XX. EQUIVALENT OR GREATER THAN UNIT HEATERS MAY BE SUBMITTED FOR APPROVAL BY THE ENGINEER. 2 ALL UNIT HEATER FANS ARE: 120 VOLTS, 1 -PHASE, 60Hz. PUMP SCHEDULE PUMP NO. LOCATION SERVES FUNCTION GPM HEAD FEET RPM HP ELECTRICAL WEIGHT LBS. MANUFACTURER MODEL REMARKS VOLTS I PHASE I Hz P-10 INSTRUMENTATATION SUMP SUMP PUMP 10 25 - 4/10 120 1 60 - LITTLE LI 9E -CIA -RFS 20' POWER CORD j NOTES: 1. PUMP WEIGHT DOES NOT INCLUDE THE INERTIA BASE. 2. PUMPS WITH VFD DRIVES SHALL HAVE VFD COMPATIBLE MOTORS. COMPUTER ROOM COOLING UNIT (CRU) SCHEDULE I MARK NUMBER LOCATION (ROOM NUMBER)TYPE NOMINAL CAPACITY TONS FAN FAN MOTOR COIL COOLING CAPACITY CHILLED WATER ' HUMIDIFIER ELECTRIC REHEAT COIL AIR FILTER REMARKS DRNE TYPE CAPACITY (CFM) ESP IN WG HP CAPACITY MBH ROOM TEMP 'f FLOW GPM EWE 'F MAX. PD 0 MAX FLOW FT! H2O CAP #/HR KW TYPE & DEPTH EFFICENCY PER ASHRAE 52-76 MAX FINAL SP WG SENSIBLE TOTAL DB WB CRU -2D4 LIEBERT UH147C 7 BELT 5250 .3 2.0 88 88 75 61 18.6 45 33.8 - - - 20 4-18X24 FILTERS CRU -2 - RECORD DRAWING A INSTALL POWER & COOLING 4972197-00 ./577800-01 B CDC RELOCATION - WIRE SHOP RELOCATION 419760 HCI/SHS 11.12.99 10.25.07 10.22.13 I ACCEPTABILITY DRAWN OPNESS -DATE12.97 THIS DESIGN AND/DR RIL'KLDLIN 3.30.98 SPECIFICATION 6 M'PROJED S. NWNEEN APPROVED BT DEPT. DATE C. RAVEN 11.12.97 CHE KED C. SPRAGUE 6.3.98 SUBDNE EQUIPMENT SCHEDULE RECEIVED CITY OF TUKWILA NOV 1 2 2013 PERMIT CENTER 90% SUBMITTAL ISSUED FOR PERMIT - fah\�. Wood CURRENT REVISION 4.19760 SYMBOL B DATE 3009 Mrth roe NE Suite leo Be9eNle wA98R 4 05.6386mo wcodhartingencwo 10.22.13 L. PROVED COSTELLO 6.3.98 APPROVED R. MCNIESH 6.3.98 mit MECHANICAL MASTER WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 PLANT 2 MIA JOB NO. 972197-00 COMP NO. DRD NO. 2-81-M1A Page 4 of 27 TERMINAL UNITS J EQUIPMENT TAG INLET SIZE IN. SUPPLY AIR CFM REO'D MAX. INLET SP IN OF WTR FAN HP CAPACITY MBH GPM MAX WPD FT OF WTR MAX APD IN OF WTR CONTROL PANEL ACCESS REMARKS MAX MIN FT -1-01 6 345 140 050 1/10 --- --- --- --- LEFT DUAL FANS F7-1-02 16 3205 1285 0.50 (2)1/2 33.3 3.30 2 .12 LEFT DUAL FANS F7-1-03 10 1270 510 050 1/3 --- --- --- --- LEFT 13.6 11-1-04 12 1830 735 0.50 1/3 29.6 3.00 .1 .02 LEFT 1,405 FT -1-05 12 1740 695 0.50 3/4 28.1 2.80 .2 .08 RIGHT 13.0 FT -1-06 6 530 215 0.50 1/10 8.6 0.90 .1 0.02 RIGHT 13.5 FT -1-07 NOT USED --- 360 0.50 1/4 14 3 150 --- --- --- 900 7-1-08 8 900 360 0.50 1/4 14 6 1 40 .1 02 LEFT 16.0 7-1-09 10 1310 525 050 1/3 21.2 2.10 1 01 RIGHT 12.2 7-1-10 10 1250 500 050 1/3 20.3 2.00 1 06 RIGHT 450 FT -1-11 12 1635 655 0 50 3/4 26.5 2.6 2 08 LEFT I FT -1-12 6 275 110 0 50 1/10 4.5 0.5 1 01 LEFT j 0 17-1-13 10 1360 545 0 50 1/3 22.0 2.20 2 07 LEFT 1,310 FT -1-14 16 2310 925 0 50 (2)1/2 37.4 3.75 2 15 LEFT DUAL FANS F7-1-15 12 1620 650 0 75 3/4 26.2 2.6 2 23 LEFT 7.5 11-1-16 8 780 315 0 75 1/4 12 6 1.2 1 06 LEFT 1,310 11-1-17 12 1840 735 0.50 3/4 29.8 3.00 1 06 LEFT 10.5 F1-1-18 16 2810 1125 0.50 (2)1/2 45.5 4.50 2 .21 LEFT DUAL FANS FT -1-19 16 2480 990 0.50 (2)1/2 40.2 4.00 2 12 LEFT DUAL FANS FT -1-20 16 2480 990 0.50 (2)1/2 40.2 4.00 .2 12 LEFT DUAL FANS F7-1-21 16 2810 1125 0.50 (2)1/2 45 5 4.50 2 .21 LEFT DUAL FANS F7-1-22 8 740 295 0.50 1/4 120 120 1 05 LEFT 37,390 FT -1-23 6 510 205 0.50 1/10 8.3 0.80 1 03 LEFT 16 3 1046 (7)24/36, (1)12/12 SA -16 08 • • 2 :4 4 5 4 R - �. -1- 5 8 908 3.0 0.50 1/4 146 140 1 E2 LEFT NOTE #6 - -0 500 5 9 I I 4 1 . . ..1 8.0 23.0 17 0 FT -1-27 12 1845 740 0.50 3/4 29.9 3.00 2 .1 LEFT 12.5 F1-1-28 10 1230 490 0 50 1/3 19.9 2.00 1 14 LEFT 42,155 FT -1-29 10 1230 490 0.50 1/3 19.9 2.00 1 14 LEFT 16.0 1 F • :3 3 •.: 900 - - 5 05 -- 13.5 >FT-1-31 6 450 90 050 1/10 7.3 0.8 1 03 RIGHT NOTES #4,5,6,7 FT -1-32 10 1200 490 0.50 1/3 19.9 2.00 1 14 LEFT NOTES #4,5,6,7 I (1)24/24 :3 • . . 1,405 24/18 ... 5 • - •L FT -2-02 12 1575 630 0 50 3/4 12.8 1.30 3 08 LEFT 1,405 FT -2-03 16 3180 1270 0 50 (2)1/2 25.8 2 60 2 22 LEFT DUAL FANS FT -2-04 6 530 210 050 1/10 8.6 0.9 1 03 RIGHT FT -2-05 16 3180 1270 0 50 (2)1/2 25.8 2 60 2 22 LEFT DUAL FANS FT -2-06 12 1590 635 0 50 3/4 25.8 2 60 2 08 LEFT FT -2-07 12 1575 630 0 50 3/4 25.8 2 60 3 08 LEFT FT -2-08 16 3180 1270 0 50 (2)1/2 51.5 5.00 2 22 LEFT DUAL FANS FT -2-09 16 3180 1270 0 50 (2)1/2 51.5 5.00 2 22 LEFT DUAL FANS 7-2-10 16 3180 1270 0 50 (2)1/2 51.5 5.00 2 22 LEFT DUAL FANS FT -2-11 12 1575 630 0 50 3/4 25.5 2 50 3 08 LEFT FT -2-12 16 3180 1270 0 50 (2)1/2 51.5 5.00 2 22 LEFT DUAL FANS FT -2-13 16 3180 1270 0.50 (2)1/2 51.5 5.00 2 22 LEFT DUAL FANS F7-2-14 10 1380 550 0.50 1/3 22 4 2.20 .1 16 LEFT FT -2-15 10 1380 550 0.50 1/3 22 4 2.20 .1 .16 LEFT F7-2-16 16 2865 1145 0 50 (2)1/2 464 4 60 2 12 LEFT DUAL FANS FT -2-17 10 1420 570 0.50 1/3 230 230 1 17 RIGHT FT -2-18 14 2840 1135 0 50 1/3 46 0 4 60 2 22 RIGHT FT -2-19 14 2430 970 0 50 (2)1/3 39 4 4 00 2 16 LEFT DUAL FANS FT -2-20 14 2840 1135 0 50 (2)1/3 46 0 4 60 2 22 LEFT DUAL FANS FT -2-21 14 2430 970 0 50 (2)1/3 39 4 4 00 2 16 LEFT DUAL FANS FT -2-22 14 2840 1135 0 50 (2)1/3 46 0 4 60 2 22 LEFT DUAL FANS FT -2-23 14 2430 970 0 50 (2)1/3 39 4 4 00 2 16 LEFT DUAL FANS FT -2-24 • 14 2840 1135 050 (2)1/3 46.0 460 2 22 LEFT DUAL FANS F7-2-25 14 2430 970 0.50 (2)1/3 39 4 4 00 2 16 LEFT DUAL FANS FT -2-26 14 2840 1135 0 50 (2)1/3 46 0 4 60 2 22 LEFT DUAL FANS 11-2-27 14 2070 830 050 (2)1/3 335 330 2 12 LEFT DUAL FANS F1-2-28 14 2130 850 0 50 (2)1/3 34 5 3 50 2 13 RIGHT DUAL FANS 11-2-29 10 1380 550 0 50 1/3 22 3 220 1 16 LEFT F1-2-30 12 1610 645 0 50 1/4 26.1 2 60 2 09 RIGHT FT -2-31 16 2840 1135 0 50 (2)1/2 46 0 4 60 2 22 LEFT DUAL FANS FT -2-32 12 1610 645 0 50 1/4 26.1 2 60 2 09 LEFT FT -2-33 14 2130 850 0 50 (2)1/3 34.5 3.50 2 13 LEFT DUAL FANS FT -2-34 14 2070 830 0 50 (2)1/3 33.5 3.30 2 .12 LEFT DUAL FANS FT -2-35 10 1380 550 050 1/3 22.4 2.20 1 .16 LEFT FT -2-39 8 880 " 350 0 50 1/4 14.3 1 40 1 .07 RIGHT VCC-2-40 12/12 1600 180 050 .5 TITUS DESV-3000 FT -2-41 8 900 360 050 1/4 14.6 150 1 .08 RIGHT FT -2-42 8 780 310 0 50 1/4 12 6 1 30 1 .06 RIGHT FT -2-43 14 2320 930 0 50 (2)1/3 37 6 3 70 2 .15 LEFT DUAL FANS NOTE: 1. CONTROL PANEL ACCESS LOCATION IS BASED ON FACING OUTLET OF FAN TER 2. FAN POWERED VAV BOXES WERE SIZED BASED ON TEMPMASTER, MODEL HVF 3. SOUND NOISE CRITERIA (NC) IS BASED ON ARI STANDARD 880-89. 4 77V 1PH 6 I. 5. FAN POW ED V BO ES W RE SI ED B SED AN TITUS, MODEL DTFS. 6. BALANCE AIRFLOW AT TERMINAL UNIT TO VALUE INDICATED IN SCHEDULE. 7. REFER TO EXISTIN CONTROL SEQUENCE ON SHE M330. TERMINAL UNITS EQUIPMENT tTAG , INLET SIZE IN. SUPPLY AIR CFM REQ'D MAX. INLET SP IN OF WTR FAN HP CAPACITY MBH GPM MAX WPD FT OF WTR MAX APD IN OF WTR CONTROL PANEL ACCESS REMARKS MAX MIN FT -2-44 14 2740 1095 0.50 (2)1/3 44.4 4.50 2 .2 LEFT DUAL FANS FT -2-45 12 2055 820 0.50 3/4 33.3 3.30 2 .12 LEFT 13.0 FT -2-46 8 780 310 0.50 1/10 12 6 1 20 1 .06 RIGHT 13.6 FT -2-47 6 430 170 0.50 1/10 7.0 070 1 .02 RIGHT 1,405 FT -2-48 8 610 245 0.50 1/4 99 100 1 .04 RIGHT 13.0 FT -2-49 6 195 80 0.50 1/10 32 0 60 1 .01 RIGHT 13.5 FT -2-50 8 900 360 0.50 1/4 14 3 150 1 .08 LEFT 900 FT -2-51 8 695 280 0.50 1/4 113 120 .1 .05 LEFT 16.0 FT -2-52 6 450 180 0.50 1/10 7 3 0 70 1 .02 RIGHT 12.2 FT -2-53 6 430 170 0.50 1/10 7.0 0 70 1 .02 RIGHT 450 FT -2-54 8 610 245 0.50 1/4 9 9 1.00 1 .04 LEFT I FT -2-55 6 530 210 0.50 1/10 8 6 0.80 1 .03 LEFT j 0 FT -2-56 6 245 100 0.50 1/10 4 0 0.60 1 .02 LEFT 1,310 FT -2-57 6 540 215 0.50 1/10 8.7 090 1 .03 RIGHT 130 FT -2-58 8 670 270 0.50 1/4 10.9 100 1 .05 RIGHT 7.5 FT -2-59 6 270 110 0.50 1/10 4.4 060 1 .1 RIGHT 1,310 FT -2-60 8 615 245 0.50 1/4 100 100 1 .03 RIGHT 10.5 FT -2-61 6 450 180 0.50 1/10 7 3 0 70 1 .02 RIGHT 7.5 FT -2-62 6 305 125 0.50 1/10 4 9 0 60 1 .03 RIGHT I FT -2-63 8 670 270 0.50 1/4 109 100 1 .05 RIGHT 10.5 FT -2-64 6 575 230 0.50 1/10 93 100 1 .01 LEFT I FT -2-65 12 1590 635 0.50 3/4 25.8 2 60 2 .08 LEFT 37,390 NOTE: 1. CONTROL PANEL ACCESS LOCATION IS BASED ON FACING OUTLET OF FAN TERMINAL BOX. 2. FAN POWERED VAV BOXES WERE SIZED BASED ON TEMPMASTER, MODEL HVFS. 3. SOUND NOISE CRITERIA (NC) IS BASED ON ARI STANDARD 880-89. 4. 277V / 1PH / 60HZ REVIEWED FOR ODE COMPLIANCE APPROVED NOV 2 7 2013 CiZy of Tukwila ILDING DIVISION SOUND ATTENUATOR SCHEDULE MARK NO SERVICE BASIS OF DESIGN MANUFACTOR & MODEL NUMBER CFM SIZE IN. WXH ATTENUATOR MIN. DYNAMIC INSERTION LOSS W-1-01 REMARKS MAX .VEL. FPM LENGTH FT. MAX.P.D. IN. WG. 63 125 250 500 1K 2K 4K BK WEIGHT LBS SA -'1 MODEL TEST FACILITY, RETURN IAC-5LFMs 1,475 42/12 450 5 .05 10.6 13.6 24.6 29.6 28.0 16.5 130 13.0 102 (1)42/12 SA -2 MODEL TEST FACILITY, RETURN IAC-5LFMs 1,475 42/12 450 5 .05 10.6 13.6 24.6 29.6 28.0 16.5 130 13.0 102 (1)42/12 SA -3 MODEL TEST FACILITY, SUPPLY IAC-5LFMs 1,405 24/18 500 5 .05 10.5 13.5 24.5 29.5 28.0 16.5 13.0 13.0 87 (1)24/18 SA24 MODEL TEST FACILITY, SUPPLY IAC-5LFMs 1,405 24/18 500 5 .05 10.5 13.5 24.5 29.5 28.0 16.5 13.0 13.0 87 (1)24/18 SA -5 SOUND DEMO CRITICAL LISTENING, SUPPLY IAC-5LFs 900 36/36 200 5 .05 14 6 19.8 32.6 37.6 39.8 27.0 21.2 16.0 150 (1)24/24, (1)12/12 SA -6 SOUND DEMO CRITICAL LISTENING, SUPPLY IAC-3LFs 900 36/36 200 3 .05 8.4 12.2 23.0 26.2 25.2 19.6 16.2 13.2 93 (1)24/24, (1)12/12 SA -;7 SOUND DEMO CRITICAL LISTENING, RETURN IAC-3LFs 450 24/24 200 3 .05 8.4 12.2 23.0 26.2 25.2 19.6 16.2 13.2 93 (1)24/24, (1)12/12 SA=8 SOUND DEMO CRITICAL LISTENING, RETURN IAC-3LFs 450 24/24 200 3 .05 8.4 12.2 23.0 26.2 25.2 19.6 162 13.2 93 (1)24/24, (1)12/12 -SA-9 SOUND DEMO CONTROL ROOM, SUPPLY IAC-5LFMs 1,310 24/24 400 5 .05 10.6 13.6 24.6 29.6 28.0 16.4 130 130 102 (1)24/24 SA -10 SOUND DEMO CONTROL ROOM, RETURN IAC-3LFMs 1,310 24/24 500 3 05 5.0 7.5 16.0 19.0 17.0 12.5 105 105 89 (1)24/24 SA -11 SOUND DEMO CONTROL ROOM, RETURN IAC-3LFMs 1,310 24/24 500 3 05 5.0 7.5 16.0 19.0 17.0 12.5 105 10.5 89 (1)24/24 SA -12 DYNAMIC CALIBRATION AREA, SUPPLY IAC-3LFMs 780 24/18 500 3 05 5.0 7.5 16.0 19.0 17.0 12.5 10 5 10.5 52 (1)24/18 SA -13 DYNAMIC CALIBRATION AREA, RETURN IAC-3LFMs 780 24/24 500 3 05 5.0 7.5 16.0 19.0 17.0 12.5 10 5 10.5 89 (1)24/24 SA -14 DYNAMIC CALIBRATION AREA, RETURN IAC-3LFMs 780 12/18 500 3 05 5.0 7.5 16.0 19.0 17.0 12.5 10 5 10 5 34 (1)12/18 SA -15 AHU-1, RETURN IAC-5LFs 37,390 180/36 850 5 44 13.3 19.3 31.3 36.3 39.3 27.3 22 3 16 3 1046 (7)24/36, (1)12/12 SA -16 AHU-2, RETURN IAC-5LFs 33,510 180/36 750 5 34 13.5 19.5 31.5 36.5 39.5 27.5 22.5 165 1046 (7)24/36, (1)12/12 SA -17 AHU-3, RETURN IAC-5LFs 18,335 180/36 500 5 0.10 14.0 20.0 32.0 37.0 40.0 28.0 23.0 17 0 1046 (7)24/36, (1)12/12 SA -18 AHU-4, SUPPLY IAC-3LFs 53,500 144/108 500 3 15 9.0 12.5 23.0 26.5 25.5 20.5 16.5 13 5 1224 (9)48/36 3 ROWS HIGH 5A-19 AHU-4, RETURN IAC-5LFs 42,155 180/36 950 5 55 13.1 19.1 31.1 36.1 39.1 27.0 22.0 16.0 1046 (7)24/36, (1)12/12 SA -20 7-1-08, RETURN IAC-5LFM 900 24/24 500 5 05 105 13.5 24.5 29.5 28.0 16.5 13.0 130 87 (1)24/24 SA -21 FT -1-09, RETURN IAC-5LFM 1,310 24/24 500 5 05 105 13.5 24.5 29.5 28.0 16.5 13.0 13.0 87 (1)24/24 SA -22 FT -1-18, RETURN IAC-5LFM 1,405 24/18 500 5 05 105 13.5 24.5 29.5 28.0 16.5 13.0 13.0 87 (1)24/18 SA -23 MODEL TEST FACILITY, SUPPLY IAC -513 1,405 24/18 5 20 SA -24 MODEL TEST FACILITY, SUPPLY IAC-5LS 1,405 24/18 5 20 SA -25 MODEL TEST FACILITY, RETURN IAC -513 2,245 48/18 5 .10 SA -26 CONFERENCE ROOM, SUPPLY 44/18 nick' TERMINAL UNITS EQUIPMENT TAG INLET SIZE IN. SUPPLY AIR CFM REVD MAX. INLET SP IN. OF WATER REMARKS MAX MIN W-1-01 8 700 140 0.49 W-1-02 7 550 110 0.52 W-1-03 7 500 100 0.45 W-1-04 10 1070 214 0.48 W-1-05 14 1400 280 0.50 W-1-06 8 700 140 0.47 W-1-07 14 2260 452 0.50 W -I-08 10 1620 324 0.50 W-1-09 10 1230 246 0.50 W-1-10 10 1230 246 0.50 A .• -. >W-1.-12 24x16 5700 1140 0.50 NOTES #3,4,5 ,e A 0 X 0 . NDIS IT ( L IS ED A 3. VAV BOXES WERE SIZED BASED ON TITUS, MODEL D . 4. BALANCE AIRFLOW AT TERMINAL UNIT TO VALUE INDICATED IN SCHEDULE. 5. REFER TO EXISTING CONTROL SEQUENCE ON SHEET M330. 'O3 DAR S, EXCEPT WHERE NOTED 880-2011. EIVED CITY OF TUKWI NOV .1 2 2013 PERMIT C ' TE CONSTRUCTION NOTES 1� PROVIDE NEW EQUIPMENT AS SCHEDULED. 90% SUBMITTAL ISSUED FOR PERMIT 1\ '.Illll Wood Harbinger STM RECORD DRAWING J/972197-00 A CDC RELOCATION - WIRE SHOP RELOCATION Jj19760 BY HGI/SHS WH APPROVED DATE SYN BENSON RI APPROVED DATE 11.12.99 481 10.22.13 ACCEPTABILITY THIS DESIGN MND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAM R. TNESS MITREED S. FRANKLIN DATE 11.12.97 3.30.98 EQUIPMENT SCHEDULE CURRENT WILSON J#19760 SYMBOL A DATE 10.22.13 'L GRNLCR G. FRANEK NECKED 11.12.97 6.3.98 APPROVED L COSTELLO 6.3.98 APPROVED R. 4CNIESH 6.3.98 TITLE WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 MECHANICAL MASTER PLANT 2 sNEtT M1B JOB NO. 972197-00 COMP NO. DWG N0. 2-81-M1B Page 5 of 27 SUPPLY DIFFUSERS, RETURN, EXHAUST, AND TRANSFER GRILLES NOISE CRITERIA SCHEDULE ROOM NAME / ROOM NUMBER CRIITTERIA (NC) MODEL TEST FACILITY / 13C3 25 MODEL BUILDUP STAGING / 1181 35 TO 40 SOUND DEMO CONTROL ROOM / 14G4 25 ARF FACILITY / 11G5 35 OPEN OFFICES AREA / 21C1 35 WAVE GUIDE FACILITY / 12G5 35 WAVE GUIDE CONTROL ROOM / 11J5 35 ELECTRICAL SHOP / 12G3 35 TO 40 MTC CONTROL ROOM / 11G7 35 MTC FLOW ROOM / 11H7 35 MTC Z -TUBE ROOM / 12H7 35 HI -TEMP TEST / 12G7 35 TO 40 MODEL LSAF FACILITY / 11F7 35 TO 40 FACILITY COMPONENTS AND TEST PARTS / 13G5 35 TO 40 DATA ROOM / 14E5 35 LAB / 11G4 35 TRANSDUCER & RECORDER CALIBRATION FACILITY / 13F3 30 CONFERENCE ROOM / 21D5 30 TO 35 PRIVATE OFFICES, WORK ROOMS, VISIBILITY ROOMS 30 TO 35 INSTRUMENTATION VAN STAGING AREA / 11F3 40 TO 45 S- " N • D " 1 ' L TA • WIRE SHOP /•11C3 40 TO 45 F . T " .1P 3:. B .1 TRANSDUCER RECORDING CALIBRATION / 1284 30 TO 35 DINING AREA / 12E7 35 TO 40 CORRIDORS 38 TO 42 DYNAMIC INSTRUMENTATION LAB / 21KJH5 35 TO 40 DYNAMIC CALIBRATION AREA / 21G5 35 TO 40 DYNAMIC INSTRUMENTATION LAB / 21H5 38 TO 42 PLUMBING FIXTURE SCHEDULE SYMBOL DESCRIPTION CONNECTION SIZE SAN V CW HW P-1 HANDICAPPED WATER CLOSET 4" 2' 1" -- P-2 WATER CLOSET 4" 2" 1" -- P-3 URINAL 2" 1-1/2" 3/4" -- P-3(H) HANDICAPPED URINAL 2" 1-1/2" 3/4" -- P-4 LAVATORY 1-1/2" 1-1/2" 1/2" 1/2" P-5 WASHFOUNTAIN 2" 1-1/2" 1/2" 1/2" P-6 SHOWER 2" 1-1/2" 1/2" 1/2" P-7 SERVICE SINK 2" 2" 1/2" 1/2" P-8 KITCHEN SINK 2" 2" 1/2" 1/2" P-9 WATER CLOSET 4" 2" 3/4" -- P-10 LAVATORY 2" 2" 1/2" 1/2" P-11 JANITOR SINK 3" 1-1/2" 1/2" 1/2" DF -1 DRINKING FOUNTAIN 1-1/2" 1-1/2" 1/2" -- DF-2 DRINKING FOUNTAIN 1-1/2" 1-1/2" 1/2" -- FD-1 FLOOR DRAIN 2" 2" -- -- FD-2 FLOOR DRAIN 2" 2" 1/2" -- FD-3 FLOOR DRAIN 4" 2" 1/2" -- FS FLOOR SINK 2" 2" 1/2" -- TP TRAP PRIMER -- -- 1/2" -- EEW EMERGENCY EYEWASH 1-1/4" 1-1/2" 1/2" -- INTAKE AIR PENTHOUSE SCHEDULE MARK NO. LOCATION SERVICE DIM. INCH CFM MANUFACTURER/MODEL REMARKS LENGTH WIDTH HEIGHT INSTALL WITHIN EXISTING EXHAUST DUCT FSD-2 WIRE SHOP 48/36 RUSKIN, MODEL CD 60 NOT INSTALLED FSD-3 N.E. CORRIDOR 10/10 PH -1 ROOF E/5 AHU-5&6 72 48 40 14,370 RUSKIN NOTE 1 NOTE: 1 PROVIDE ACCESS DOOR(S) ON EAST SIDE FOR ACCESS TO MOTOR OPERATED DAMPERS LOCATED AT ROOF. FIRE / SMOKE DAMPERS MARK NO. SERVICE SIZE MANUFACTURER / MODEL REMARKS WXH(IN) FSD-1 N.W. CORRIDOR 12/12 RUSKIN, MODEL FSD 60 INSTALL WITHIN EXISTING EXHAUST DUCT FSD-2 WIRE SHOP 48/36 RUSKIN, MODEL CD 60 NOT INSTALLED FSD-3 N.E. CORRIDOR 10/10 RUSKIN, MODEL FSD-60 INSTALL WITHIN NEW RA DUCT ATTACHED TO EXISTING OSA DUCT FSD-4 LOBBY 24/24 RUSKIN, MODEL FSD-60 INSTALL WITHIN NEW RA DUCT ATTACHED TO EXISTING OSA DUCT FSD-5 JANITORS ROOM 12/12 RUSKIN, MODEL FSD-60 COMPUTER ROOM FSD-7 MAIN CORRIDOR 16/16 RUSKIN, MODEL FSD-60 11 FSD-7A MAIN CORRIDOR 12/12 RUSKIN, MODEL FSD-60 55 FSD-8 W. CORRIDOR 14/14 RUSKIN, MODEL FSD-60 LEIBERT, MODEL BUO67A FSD-9 ELEVATOR MACHINE RM 12/12 RUSKIN, MODEL FSD-60 - FSD-11 WOMEN'S LOCKER RM 16/16 RUSKIN, MODEL FSD-60 - FSD-12 MEN'S LOCKER ROOM 16/16 RUSKIN, MODEL FSD-60 3 FSD-13 WOMEN'S TOILET 12/24 RUSKIN, MODEL FSD-60 DX -2 FSD-14 MEN'S TOILET 12/24 RUSKIN, MODEL FSD-60 0.5 FSD-19 N.E. CORRIDOR 18/18 RUSKIN, MODEL FSD-60 15.0 FSD-20 N.E. CORRIDOR 16/10 RUSKIN, MODEL FSD-60 26 7 FSD-21 N.E. CORRIDOR 10/8 RUSKIN, MODEL FSD-60 ROOF FSD-22 JANITOR'S ROOM 22/22 RUSKIN, MODEL FSD-60 - FSD-23 INST ST AREA 36/16 RUSKIN, MODEL FSD-60 277 FSD-24 INST ST AREA 20/18 RUSKIN, MODEL FSD-60 SPLIT SYSTEM. HPR COND. UNIT W/ PROPOP FAN FAN FSD-25 INST ST AREA 36/16 RUSKIN, MODEL FSD-60 FSD-26 INST ST AREA 52/14 RUSKIN, MODEL FSD-60 FSD-27 INST ST AREA 10/10 RUSKIN, MODEL FSD-60 FSD-28 INST ST AREA 26/26 RUSKIN, MODEL FSD-60 CONTROL DAMPERS MARK NO. SERVICE SIZE MANUFACTURER / MODEL REMARKS WXH(IN) CD -EF -5 WIRE SHOP 30/20 RUSKIN, MODEL CD 60 INSTALL WITHIN EXISTING EXHAUST DUCT CD-AHU-6-OSA WIRE SHOP 48/36 RUSKIN, MODEL CD 60 INSTALL WITHIN EXISTING OSA DUCT CD-AHU-6-RA-1 WIRE SHOP 36/36 RUSKIN, MODEL CD 60 INSTALL WITHIN NEW RA DUCT ATTACHED TO EXISTING OSA DUCT CD-AHU-6-RA-2 WIRE SHOP 36/36 RUSKIN, MODEL CD 60 INSTALL WITHIN NEW RA DUCT ATTACHED TO EXISTING OSA DUCT NOTE: PROVIDE 24 VOLT ACTUATOR REFRIGERATION/CONDENSER UNITS MARK NO. SERVICE LOCATION FAN HUMIDIFIER FILTERS ENTERING AIR LEAVING AIR ELECTRICAL MANUFACTURER/MODEL REMARKS CFM HP S.P. IN E..C. LB/HR LB HR % EFFICIENCY T DEG F % RH TOTAL MB H DEG -F VOLTS PHASE Hz FLA DX -1 COMPUTER ROOM COMP COL D.5 E.5UTER J200M 2800 2.0 0.5 11 30 72 50 58.0 55 480 3 60 28.9 LEIBERT, MODEL BUO67A ELECTRIC REHEAT CND -1 SERVES DX -1 ROOF - 0.5 - - - - - 65.0 - 480 3 60 13,4 LEIBERT, MODEL PFC067A SPLIT SYSTEM. HORIZONTAL COND. UNIT W/ PROP FAN DX -2 DATA VAULT DATA VAULT 750 0.2 0.5 2.5 30 72 50 15.0 55 277 1 60 26 7 LEIBERT, MODEL MMD18E ELECTRIC REHEAT CND -2 SERVES DX -2 ROOF - 0.2 - - - - - 19.5 - 277 1 60 10,7 LEIBERT, MODEL PFCO20A SPLIT SYSTEM. HPR COND. UNIT W/ PROPOP FAN FAN FILET ; CONDENSER UNITS DESIGN: SUMMER 95'F/ WINTER 0'F REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION CONSTRUCTION NOTES PROVIDE NEW EQUIPMENT AS SCHEDULED. 90% SUBMITTAL ISSUED FOR PERMIT RECEIVED CITY OF TUKWILA NOV 1 '2 2013 PERMIT CENTER Wood Harbinger 4111\1\11 30o9 urth Ane NE. Sole wb BoII o WA 9Boo4 425638.6ODo r00ERTNNTgeT.mm SYM A RECORD DRAWING Jj972197-00 CX RELOCATION - WIRE SHOP RELOCATION J+19760 BY HGI/SHS WH APPRCRED DATE SIA BY APPRO+ED DATE 11.12.99 N81 10.22.13 BOE/A/G® ACCEPTABILITY 1H6 DESIGN AND/OR SPECIFICATION 6 APPROVED APPROVED BY DEPT. DATE DRAWN R.R. TOPNESS MITRED S. FRANKUN DATE 11.12.97 3.30.98 SUEMTLE EQUIPMENT SCHEDULE CURRENT REVISION 419760 SYMBOL A DATE 10.22.13 •1:NGINLLN G. FRANEK CHECKED G. SPRAGUE 11.12.97 6.3.98 APPROVED L.. COSTELLO 6.3.98 APPROVED R. 4CNIESH 6.3.98 MECHANICAL MASTER WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 PLANT 2 tEET MIC Jos Na 972197-00 COMP NO. DWG NO. 2-81-M1C Page of 27 S GENERAL NOTES 1 CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION AND INSTALLATION. FIELD VERIFY DIMENSIONS TO EXISTING BUILDINGS. OBTAIN APPROVAL FOR PROPOSED FIELD CHANGES TO THE WORK FROM THE ENGINEER OR THE OWNERS REPRESENTATIVE BEFORE THE FABRICATION AND WORK IS INSTALLED. 2 ALL EQUIPMENT AND MATERIALS SHALL BE NEW. REUSE OF EQUIPMENT OR MATERIALS IS NOT PERMITTED. 3 THE CONSTRUCTION AREA SHALL BE MAINTAINED IN A CLEAN AND ORDERLY MANNER AT ALL TIMES. 4. EQUIPMENT OR MATERIAL DAMAGED DURING CONSTRUCTION SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REPLACE AT HIS COST. 5 EQUIPMENT AND MATERIALS SHALL BE STORED AT LOCATIONS AS DIRECTED BY THE OWNER AND THE ENGINEER. PROVIDE PROTECTION FROM PHYSICAL DAMAGE, DUST, WATER AND THE ELEMENTS. 6. CONTRACTORS AND SUB -CONTRACTORS SHALL COORDINATE WITH OTHER DISCIPLINES TO PREVENT INTERFERENCES AND TO MAINTAIN SUITABLE EQUIPMENT ACCESS FOR SERVICING AND MAINTENANCE BEFORE THE WORK IS INSTALLED. 7. THE DRAWINGS AND SPECIFICATIONS DO NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF PROVIDING COMPLETE OPERABLE SYSTEMS. 8. ALL CRAFT PERSONNEL SHALL BE QUALIFIED IN THEIR FIELD OF WORK IN ACCORDANCE WITH CODES AND CRAFT STANDARDS. ALL WORK SHALL BE INSTALLED TO THE HIGHEST INDUSTRY STANDARDS OF WORKMANSHIP. FIRE PROTECTION 1. ALL FIRE PROTECTION PIPING SHALL BE INSTALLED IN ACCORDANCE WITH SPECIFICATIONS AND LOCAL CODE REQUIREMENTS. 2 SEE DRAWINGS 2-81-M525 AND M526 FOR PIPING SUPPORTS. 3 SEE DRAWING 2 -B1 -M515 FOR DETAILS. 4 SEE PLANS FOR OTHER PERTINENT NOTES. PLUMBING 1 ALL PLUMBING SHALL BE INSTALLED IN ACCORDANCE WITH SPECIFICATIONS AND LOCAL PLUMBING CODE REQUIREMENTS. 2 CONTRACTOR SHALL INSTALL HIGH POINT VENTS AND LOW POINT DRAINS AS REQUIRED TO PERMIT FULL DRAINAGE OF ALL WATER PIPING. 3. SLOPE ALL SANITARY LINES AT 1/4" PER FOOT (MINIMUM SLOPE) UNLESS NOTED OTHERWISE. 4 SEE CML DRAWINGS FOR UNDERGROUND PLUMBING FOR 5 FEET AND BEYOND BUILDING FOUNDATION. 5 SEE SPECIFICATIONS FOR INSULATION OF HOT WATER (HW), HOT WATER CIRCULATION (HWC) AND COLD WATER (CW) PIPING. 6. SEE DRAWINGS 2-81-M1O, M 1 b AND M 1 c FOR EQUIPMENT SCHEDULES. 7. ALL OPEN ENDED PIPING SHALL BE CAPPED OFF TO PREVENT DUST AND DEBRIS FROM ENTERING THE PIPING. 8. SEE DRAWINGS 2-81-M525 AND M526 FOR PIPING SUPPORTS. 9. SEE DRAWINGS 2-81-M513 & M514 FOR DETAILS. ►A� 1. SEE 2-81-M310 AND 2-81-M311 FOR CONTROL SEQUENCES. 2. SCHEDULES. 2- 1b NI 1c 0 9 3. SEE ARCHITECTURAL AND STRUCTURAL DRAWINGS SPECIFICATIONS AND DRAWINGS FOR EQUIPMENT MOUNTING AND ACCESS PLATFORMS. 4. SECOND FLOOR BOTTOM OF DUCTWORK SHALL NOT BE LOCATED BELOW 11'-0" ABOVE FINISHED FLOOR (AFF) UNLESS OTHERWISE NOTED. 5. SECOND FLOOR TOP OF DUCTWORK SHALL NOT BE LOCATED ABOVE 14'-0" ABOVE FINISHED FLOOR (AFF) UNLESS OTHERWISE NOTED. 6. THERMOSTAT LOCATIONS SHALL BE LOCATED AS SHOWN ON DRAWING. MOUNT 5'-0" AFF, UNLESS NOTED OTHERWISE. 7. ALL DUCTWORK SHALL BE SUPPORTED FROM STRUCTURAL MEMBERS ONLY 8. ALL DUCTWORK SHALL BE INSTALLED IN ACCORDANCE WITH SPECIFICATIONS, CODE AND SMACNA FOR MEDIUM AND LOW PRESSURE SYSTEMS. 9. SEE DRAWINGS 2-81-M500 THRU M510 FOR DETAILS AND SECTIONS. 10. DUCTWORK OPENINGS SHALL BE PROTECTED AT ALL TIMES DURING CONSTRUCTION TO PREVENT DUST AND DEBRIS FROM ENTERING THE DUCTWORK. 11. DUCTWORK TRANSITIONS SHALL BE CONCENTRIC UNLESS OTHERWISE NOTED. 12. ALL DUCT DIMENSIONS ARE INSIDE, OPEN FREE AREA. 13. FOR TYPICAL HVAC SECTION, SEE SECTION A ON DRAWING 2-81-M504. 14. FOR MAIN DUCT RUNS ON FIRST FLOOR, BOTTOM OF DUCTWORK SHALL NOT BE LOCATED BELOW 16'-0" ABOVE FINISHED FLOOR (AFF) UNLESS OTHERWISE NOTED. 15. FOR MAIN DUCT RUNS ON FIRST FLOOR, TOP OF DUCTWORK SHALL NOT BE LOCATED ABOVE 17-6" ABOVE FINISHED FLOOR (AFF) UNLESS OTHERWISE NOTED. 16. ELEVATION OF TRANSFER GRILLES IN ROOMS WITHOUT A CEILING SHALL BE 12'-0". ELEVATION OF TOP OF GRILLES IN ROOMS WITH A CEILING SHALL BE 6" BELOW FINISHED CEILING. 17. MOUNT ALL CABINET UNIT HEATERS AT 16'-0", UNLESS OTHERWISE NOTED. 18. SEE DRAWINGS 2-81-M322 THRU M333 FOR CONTROL P&ID'S. HVAC PIPING 1. SEE DRAWINGS 2-81-M316 THRU M321 FOR FLOW DIAGRAMS. 2. SEE DRAWINGS 2-81-M450 THRU M501 AND 2-81-M530 FOR DETAILS. 3. SEE DRAWINGS 2-81-M1a, M 1 b AND M 1 c FOR EQUIPMENT SCHEDULES. 4. SEE PLANS FOR OTHER PERTINENT NOTES. 5. SEE DRAWINGS 2 -B1 -M322 THRU M333 FOR CONTROL P&ID'S. REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION 90% SUBMITTAL ISSUED FOR PERMIT RECEIVED CITY OF TUKWILA NOV .1 2 2013 PERMIT CENTER Wood Harbinger pop uAh Ave NE. Sub HE EWEN. WA 98o34 a00mo WODBuHNRPcmm RECORD DRAWING 4972197-00 CDC RELOCATION - WIRE SHOP RELOCATION 419760 BY HGI/SHS WH APPROVED DATE GYM REV'BON BY APPROVED DATE 11.12.99 681 10.22.13 g)LAmerAE-,Avc. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN S. FRANKUN MIMEO G. FRANEK DATE 4.10.98 4.13.98 GENERAL NOTES CURRENT REVISION J(J19760 SYMBOL A DATE 10.22.13 tNLINELH C. FRANEK CHECKED G. SPRAGUE 4.10.98 6.3.98 L 60 ELLO 6.3.98 APPROVED R. MCNIESH 6.3.98 'MU WIRE SHOP RELOCATION TO 2-81 MECHANICAL MASTER BUILDING 2-81 PLANT 2 GNEET M2 JOB 972197-00 HD COUP NO. ONG NO. 2-81-M2 Page 7 o127 41/77 /N11 7.141/1 A11 30,-0' 'TO 'INTO 20/12 120 MOD RG 20/20 FOR CONTINUATION SEE SHEET 2-81-1M10 CORRIDOR 11103 I 30/100 80/120 1M12 M502 W3 20/12 52/140 SHIPPING AND RECIEVINC - N16 11164 D 8/ 10 C' RG 12/12 5 CFM RG 30/12 1770 CFM 30/100 1`0§ POC TG 12/ 2 400 C M 260 280 FI F(' 1 ,6 RG 18/10 750 CFM 80 UP TO EF -12 280 UP TO EF -06 200 UP TO EF -01 20/10 RA BELOW 20/30 UP TO EF -05 AD 140 UP TO EF -15 E 12/12 FIELD TESL BUILDUP - RID 11364 TG 12/12 80 W/VD EVA) R H. RnDM F: D-AHU-6-OSA G 2/12 ;JI) 100 1140 148/36 ABO 1M12 M506 1 12 M504 SG 6/6 170 CFM 1M12 M506 30/24 30/24 68/18 80 (BELOW) SD 12/12 300 CFM (TYP OF 3) 120 CD-AHU-6-RA-2 FOR CONTINUATION IN THIS AREA, SEE1M12 o❑ 144/20 M1M456 SG 12/6 150 CFM TYP OF 3 62/38 L hiI , 142/24 I WIRE • ESH 1M12 0 0 0 0 SD 18/18 700 CFM DUCTWORK SCALE: 1/8'=l'-0' z 8 0 moi VESTIBULE I 12E7 I 0 B 0 LEGEND LEGEND MOTORIZED DAMPER POC = POINT OF CONNECTION GENERAL NOTES 1. SEE SUPPLY DIFFUSER, RETURN, EXHAUST AND TRANSFER GRILLE SCHEDULE ON DWG 2-81-M1 PROVIDE ACCESS DOOR IN SA DUCT DOWNSTREAM FRO r EAC. FIR MOKE DAMPER. 0 0 REVIEWED FOR ODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila UILDING DIVISION `0 90% SUBMITTAL ISSUED FOR PERMIT REFERENCE DRAWINGSWI M310, M311, 27 M330 M1M456, M506 CONSTRUCTION NOTES RELOCATE EXISTING TEMPERATURE SENSOR AS SHOWN. PROVIDE NEW ROUND DIFFUSER. PROVIDE NEW RIGID ROUND DUCT TO EXTEND FROM EXISTING DUCT AND ELBOW DOWN TO NEW DIFFUSER. NEW DUCT TO MATCH SIZE OF EXISTING. PROVIDE NEW MOTORIZED DAMPER IN EXISTING DUCT AT THIS LOCATION PROVIDE NEW RETURN GRILLE ON EXISTING DUCT. MOUNT GRILLE ON FACE OF SOFFIT. PATCH AND REPAIR SOFFIT PER ARCHITECTURAL. STEAM CLEAN INTERIOR OF FORMER GREASE DUCT AS PART OF THIS WORK. PROVIDE NEW FAN COIL AND ASSOCIATED DUCTWORK. REFER TO SCHEDULE ON SHEET MTA FOR ADDITIONAL INFORMATION. PROVIDE NEW SECTION OF DUCT WHERE VOLUME DAMPER WAS REMOVED DUCT SIZE TO MATCH EXISTING. PROVIDE NEW FAN TERMINAL UNIT. 0 0 0 0 0 0 0 1M13 2-81 BUILDING KEY PIRECEIV4D e1`ry OF TURWILA NOV .1 2 2013 PERMIT CENTER Wood Harbinger mO9 lath Aare NE &Iztoo O.8.ate WA 98004 aoemnrNnger.am RECORD DRAWING 4972197-00 HGI/SHS MODIFY 2-81 CAFETERIA LAPTOP HOTELING 10/13884-50 CDC RELOCATION - WIRE SHOP RELOCATION J119760 11 12.99 7/24/00 1.12.12 10.22 13 el__ArwArc. ACCEPTABILITY 1H5 DESIGN AND/OR SPECIFICATION 5 APPROVED APPROVED BY DEPT. DATE K. [Won A. P'MELTDR INWNEEN G. FRANEK CHECKED C. SPRAGUE 1.12.98 1.1298 m DUCTWORK 4119760 10.22.13 WIRE SHOP RELOCATION TO 2-81 APPROVED L COSTELLO APPROVED R. MCNIESH 6.3.98 BUILDING 2-81 MECHANICAL MASTER COL. A -F/3-8 PLANT 2 DWG NO. 972197-00 2-81-1M12 Page 8of27 U (B) 30'-0" U U CU U 30'-0" 30.-0" a 3/4" FT 4)m—iL-� 0 1" FUTURE CONNECTION MATCHLINE SEE SHEET 1M60 1 1/2" FUTURE CONNECTION HWS— HWR BUTTERFLY VALVE IN RISER 1' 1 V U v v 3"x2" III_I III I 061 0o c SEE DETAIL 1M62 M1M456 1=1 f —11 I I I I III I I I I III I I jjI I I col AH 05 3/4" C C �\,� C -II -IoI 3/4" 3/4" ti 4"x2" 3"x2" .11. 1 1 1 1 3/4" ■ I 11 161 T (TYP) ALL FAN t 1-227 ERMINAL UNITS HVAC - PIPING SCALE: 1/8"=1'-0" 101 1 1/2" FUTU CONNECTION 2" CHWR 2 RE MATCHLINE SEE SHEET 0 U GENERAL NOTES 1 SEE COIL CONNECTION DETAILS ON SHEET M530. 2. ALL HVAC PIPING SHALL BE A MINIMUM OF 18'-0" ABOVE FINISHED FLOOR. 3. SEE DRAWING 2-81—M525, M526 FOR PIPE HANGER DETAILS. ® SEE 1M62 FOR PIPE M526 1M62 PENETRATION M526 DETAILS 5. SEE DRAWING 2-81—M319. M320, M321 FOR SYSTEM PIPING DIAGRAM. 6 MOUNT UNIT HEATER AS HIGH AS POSSIBLE. REFERENCE DRAWINGS REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION 90% SUBMITTAL ISSUED FOR PERMIT CONSTRUCTION NOTES RtetiVE D C ILA NOV 1 2 2013 PERMIT CENTER VIII iillNl�� Wood Harbinger WON urth Nle NE. Suite am Bellevue WA98004 QSkU3a000 rDDmdrmntecmm SYM A REVISION RECORD DRAWING 4972197-00 CDC RELOCATION - WIRE SHOP RELOCATION 4119760 NY 601/SHS WH APPROVED DATE SYM REVISION et APPROVED DATE 11.12 99 10.22.13 gLIM7E,AW ACCEPTABILITY THIS DESIGN AND/OR SPELTFIGTION IS APPROVED APPROVED 6Y DEPT. DATE -DRAWN S. FRANKLIN A. NAPIER 12 T1 12.8.97 3.18.98 SUBTITLE HVAC PIPING CURRENT REVISION 4119760 mem A DATE 10.22.13 1ENWNEER E. YOOSEFIAN CHECKED G. SPRAGUE 12.8.97 6.3.98 APPROVED L. COSTELLO 6.3.98 APPROVED R. MCNIESH 6.3.98 TITLE MECHANICAL MASTER WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 COL. A—F/3-8 PLANT 2 sHET 1 M62 JOB No. 972197-00 COMP NO. DWG NO. 2-81-1M62 Page 9of27 D ( N2 C) 3/4" HYDRAULIC UNIT SEE DETAIL l 1M1101M513 3/4" MECH. BUILDUP 3/4" STAGIIG AREA - S10 1 1/2"V ,I 1151 P-7 EEW-1 DF -1 1/2 A A �1182> - L- _ VENT UP TO ROOF 2"FD-2 FCO 3/4" 1-3 • BOP 14'-0" 3/4*CW A L y_9)3P 19'-0 A 3/4 ELECTRICAL SHOP - S9 1 1163 1 3/4"CW -" \1 767 W4 ; II 1/21/1 CW A 3/4" a „,-1/2” 3/4" L3 A 1/2" E 3/4 3/4" IC. - M110 3 4" 1/2 M51 1/2" G t L -2E1 2x1 CO, iDCR I 1 E II J MODEL TEST FACILITY - S5 1303 1 i4C3 `3/4" 1303 "O""I OR 1/21 a MATCHLINE SEE SHEET 2-81-1M111 1 1/4" 3/4" 3 1 1/2" 3 vAIMIA•AIIMAAA''.11111W'AIMINAAIIIRINIA:I=PA:. �� 0 REVIEWED FOR CODE PR VED CE AP NOV 2 7 2013 City of Tukwila BUILDING DIVISION PLUMBING SCALE: 1/8"=1'-0" O 1/2" 2 1/2" 1 1/4" 1 1/4" 2 1/2" LEGEND GENERAL NOTES 1 > POINT OF USE WATER HEATER MOUNT ON METAL SHELF LOCATED 6'-6" MINIMUM ABOVE FLOOR. LOCATION AS APPROVED BY BOEING REP PROVIDE SEISMIC RESTRAINT STRAP ANCHORED TO WALL. PROVIDE SHELF SUPPORT BRACKETS CONSTRUCTED FOR 100 POUND STATIC LOAD. PROVIDE SHUT OFF VALVE IN CW LINE TO HEATER. 2. FOR TYPICAL INSTALLATION OF AIR OUTLETS AND BACK- FLOW PREVENTOR SEE TYPICAL PLUMBING DETAIL SHEET M513. 3 > INSTALL WATER FILTER FOR DRINKING FOUNTAIN DF -1. REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE NEW COMPRESSED AIR PIPING, TYP. RECEIVED CITY OF TUKWILA NOV 1 2 2013 PERMIT CENTER 90% SUBMITTAL ISSUED FOR PERMIT 2-81 BUILDING KEY PLAN MAA MIS O ,! I\\I\i Wood Harbinger woo DAN Are NE Butte too Bellevue IVA 90uo4 405409.6000 rooa6ar6ager.mm SIM A REVISION RECORD DRAWING J1972197-00 CDC RELOCATION - WIRE SHOP RELOCATION 419760 BI HGI/SHS WH APPROVED DATE SYN REVISION BY NPPROVED DATE 11.12.99 MBL 10.22.13 BOE/A/6® ACCEPTABILITY TOO DESIGN 019/OR SPECIFICATION 6 APPROVED APPROVED BY DEPT. DATE TRAVM IA HOLT OWNED ANKLIN k LLr6 C. FRANEK CHECKED G. SPRAGUE DATE 12.15.97 3.30.98 SUBTILE PLUMBING CURRENT REVISION J#19760 SriBOL A DATE 10.22.13 12.15.97 6.3.98 RINED L COSTELLO 6.3.98 APPROVED R. MCNIESH 6.3.98 TITLE WIRE SHOP RELOCATION TO 2-81 MECHANICAL MASTER BUILDING 2-81 COL. A -F/1-3 PLANT 2 SHEET 1 M 110 JOB NO. 972197-00 CONP NO. OMD NO. 2-61-1M1 O Page 10 of 27 VEaIIbt LL 12[1 I2Ei� CORRIDPR 13E11 I 1= AV AT HIGH POINT MATCHLINE SEE SHEET x 1 1/2" SAN DN { 6" RWL (TYP OF 2) Mr A 24"X24"X24" SUMP 1 1/2" COPPER NO HUB, NO HUB BANDS 3 INSTRUMENTATION VAN STAGING AREA - N20S11 1/2" WOMEN'S I 12J2 1 `11th 12K1 MATCHLINE SEE SHEET 2-81-1M113 (` " 2" PLUMBING SCALE: 1/8"=1'-0" O 1 1/2" 1 1/4" 3" L REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION LEGEND POINT OF CONNECTION GENERAL NOTES FOR RISER DIAGRAM SEE 2-81-U511. REFERENCE DRAWINGS CONSTRUCTION NOTES I> PROVIDE NEW COMPRESSED AIR PIPING, TYP PROVIDE NEW 2'A CONNECTION TO EXISTING 2" A PIPE 2-81 BUILDING RECEIVEDKEYRoLL oL"" O CITY OF TUKWILA NOV 1 2 2013 PERMIT CENTER 90% SUBMITTAL ISSUED FOR PERMIT II, Wood Harbinger 3009 lulls AIIe NE, Suite M» Bellevue WA 98004 40330.6000 wo0AurMnfer.ccm SYM REVISION A B RECORD DRAWING CDC RELOCATION - PALLET RACK MOVE CDC RELOCATION - WIRE SHOP RELOCATION 4972197-00 419760 3119760 BT HGI/SHS WH WH APPROVED DATE $YM BT APPROVED DATE MBL MBL 11.12.99 09.12.13 10.22.13 gLASFAKEIAW ACCEPTABILITY T116 DESIGN AND/OR SPECIFCATION IS APPROVED DRAWN M. HOLT CHECKED S. FRANKLIN 091E 12.15.97 3.30.98 PLUMBING CURRENT REVISION J1119760 SYMBOL B DATE 10.22.13 APPROVED BY DEPT. DATE EN(,9Ltf G. FRANEK EHECKED G. SPRAGUE 12.15.97 6.3.98 APPROVED L COSTELLO 6.3.98 APPROVED R. MCNIESH 6.3.98 TDLE WIRE SHOP RELOCATION TO 2-81 MECHANICAL MASTER BUILDING 2-81 COL. F -L/1-3 PLANT 2 SHEE, 1 M 111 JOB N0. 972197-00 COMP N0. DWG N0. 2-81-1M1 1 Page 11 of 27 30'-0" (y) SHIPPING AID RECIEVINL - N16 1/2" 30'-0" 30'-0" CO 1 30'-0" CORRIDOR 1101 Ei 1 1/4" 2 1/2" 1/ TRANSD ORD CA IIII Illli MS I us 4" WASTE UP MS I IL` 0 MI CO� J D 1/2" ELECTRICAL 14E3J 1 3" P -TRAP BELOW & UP TO J -SINK 2"V 1M112IM454\ N\ N FIELD TEST BUILDUP - N10 L1364 I TABLE mc-.1 TAB E p TABLE 30x6, ABLE SOnn RWL IiB5 a;S M,'S U./5 M/S I 0 ELEVATOR MACH. ROOM 1 11E1 _I 374" :11E• 111...-."�� • S5 DUPLEX FLEXIBLE AIR DROP, SEE ' ( "\ (4 TYp) 1M112MM513 VENDING I 12's (2) DUPLEX FLEXIBLE AIR W1 y DROP, SEE 1M112 M513 DESK 1/2" 2 1/2 1 1/4"--� \ 13E5 1/2"A m 2 wR 7,7 • I N W En N Li LO LiJ E H IWE7;- anx PCTBC T48LC PCT E7 DESn PLUMBING SCALE: 1/8"=1-0" O U v[SiIBULE li_E/I L A.,1 S4 (4) 2 1 /2'CW 1 1/2j -IW 1/2"14AC 0 N, 5 M '01 co REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE NEW COMPRESSED AIR PIPING (TVP). PROVIDE TWO DUPLEX AIR DROPS AT WORK STATION AS SHOWN. PROVIDE ADJUSTABLE HOSE WITH HOSE CLAMP SUPPORT WITH OD (TYP). CENTER DROPS BETWEEN WORK STATIONS. PROVIDE DUPLEX AIR DROPS AT WORK STATION AS SHOWN. PROVIDE ADJUSTABLE HOSE WITH HOSE CLAMP SUPPORT WITH OD (TYP) CENTER DROPS BETWEEN WORK STATIONS. PROVIDE COMPRESSED AIR DROP, TYPICAL City of Tukwila BUILDING DIVISIVED -( 8 ) CITY OF TUKWILA NOV 1 2 2013 PERMIT CENTER 90% SUBMITTAL ISSUED FOR PERMIT 2-81 BUILDING KEY PLAN sAu. rs 0 \\ /A1111 Wood Harbinger pee Nath Am NE. Sully Tm Bellevue WA 98004 405Aa8.0000 woomarm08er 100 SYM REVISION A B RECORD DRAWING J1972197-00 SHOP AIR UNE W.0.5944214 LAPTOP HOTELING ID113884-50 CDC RELOCATION - WIRE SHOP RELOCATION J119760 Br HCI/SHS WDB WDB WH APPROVED DATE SYN Br APPROVED DATE 11 12 99 11/7 07 1.12 12 MBE 10 22 13 g)LIFLY.E,AIG® ACCEPTABILITY THS DESIGN AND/OR SPECIFICATION B APPROVED DRAWN DATE U. BOLT 12.8.97 SFIC S. FRANKLIN 3.30.98 SUBTITLE PLUMBING CURRENT REVISION J#19760 SYMBOL C DATE 10.22.13 APPROVED BY DEPT DATE ENGINEER G. FRANEK 12.8.97 CHECKED . SPRAGUE 6.3.98 APPROVED COSTEU.O 6.3.98 APPROVED R. MCNIESH 6.3.98 TITLE MECHANICAL MASTER WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 COL. A -F/3-8 PLANT 2 SHEET 1M112 JOB NO. 972197-00 COMP NO. DWG N0. 2-81-1M1 2 Page 12 0127 SIM A B 30'-0" 0) 30'-0" 30'-0" Q_j 30'-0" 30'-0" ED CORRIDOR 17'-0" 11D3 MATCHUNE SEE SHEET 1M261 18'-B" _TYP ELEV_ ELEV. 17-0" (1'CE SHIPPINt, AND ECIEVING - N16 1104 1 1/2ANSDUCER RECORD CAL.- N26 °O 1 128 1 1/4" H 1" 1: ELEV. 1E'-8" TYP ELEV. 17'-0" ELEV. 1 1/2"0 V 1 1/2" o 16'-1" ELEV. 1" • 1 1/2" 8" UP TO 2ND FLOOR 1 1/2" 1 1/2" DRY SPRINKLER FOR ORDINARY HAZARD GROUP 2 OCCUPANCY, (W/IN OUTSIDE CANOPY) ' } 1 1/4" 1" 1" FE.D TEST 1" BUILP P -1019 3E4 I 1 1/4" 1 1/4" 1" ELEVATOR CONT REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 () City of Tukwila BUILDING DIVISION OL VALVE SEE !�? 1M262 M515 1 1/2" 1 1 2 17'-0" VENDING i i5 16'-2" ELEV. 1135 I 6 1M262 M515 1M262 M515 . 17'-0" ❑ ELEV REVISION RECORD DRAWING LAPTOP HOTELINC CCC RELOCATION - WIRE SHOP RELOCATION J1972197-00 ID113884-50 J119760 Ttka" ELEV 0 1" 1" 1 ,r (7) DRY PENDANT HEADS TO PROTECT UNDER 0 THE 10' WIDE MIL CEILING. I c 0 1 4 1 1 2" BY HCI/KIC WDB WH IPPRINED DATE SYN REVSIDN BY APPROVED FIRE PROTECTION SCALE: 1/8"=1'-0" DATE 8.7 01 1.12 12 881 10.22 13 gLAWIE,AW 0 ACCEPTABILITY THS DESIGN AND/OR SPECIFlGnON IS APPROVED APPROVED BY DEPT. DATE DRAWN K. S. FRANKLIN -DATE 06.28.01 7.31.01 7 8 LEGEND SYM SPRINKLERS MODEL TYPE TEMP. NPT K FAC. FINISH o CENTRAL A SSU 165 1/2" 5.6 BR. • CENTRAL GB RECESSED 155 1/2" 5.6 CHR. • CENTRAL A DRY PEND. 212 1/2" 5.6 CHR. CENTRAL A SSU 212 1/2" 5.6 BR. o CENTRAL A SSU 212 1/2" 5.6 BR. 2 -WAY SEISMIC BRACE X4 -WAY SEISMIC BRACE GENERAL NOTES 1. SYSTEMS ARE ORDINARY HAZARD, PIPE SCHEDULE (30% OVERSIZED MAINS) MAX. HEAD SPACING = 130 SQ. FT. PER HEAD. 2. INSTALLATION TO CONFORM WITH NFPA #13 AND FACTORY MUTUAL. 3. USE SCH. 40 PIPE FOR 2 1/2" OR SMALLER AND SCH. 10 FOR 3" PIPE AND LARGER. 4. USE CENTRAL SPRINK CLASS 125 C.I. SCREWED FITTINGS, WELDED & GROOVED FITTINGS AND COUPLINGS. 5. ALL MATERIAL TO BE NEW, U.L. AND F.M. APPROVED. 6. ALL WELDING TO CONFORM WITH AWS D10.9 AND BE PERFORMED IN THE SHOP. 7. ALL ELECTRICAL WIRING & PROTECTION OF HEADS FROM PAINT, BY OTHERS. REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE WET PIPE FIRE SPRINKLER PROTECTION IN THIS AREA PER SPECIFICATIONS MODIFY EXISTING FIRE SPRINKLER SYSTEM AS REQUIRED. CONNECT TO EXISTING 6" MAIN. PROVIDE NEW WET PIPE FIRE SPRINKLER SUPPLY FOR CORRIDOR SPRINKLER. CONNECT TO EXISTING CAPPED PIPING AS SHOWN. RECEIVED CITY OF TUKWILA NOV 1 '2 2013 PERMIT CENTER 90% SUBMITTAL ISSUED FOR REVIEW SUBTITLE FIRE PROTECTION 2-81 BUILDING KEY PLAN xNE ea O Wood Harbinuer CURRENT REVISION J#19760 SYMBOL B 7009 Muth tree NE. SUI4 loo Bellevue WA 98004 Rsbl9.6000 w00mMrDmEecmm DATE 10.22.13 LNIMR.tN COSCO CHEERED APPROVED APPROVED 9.4.98 TITLE MECHANICAL MASTER WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 COL. A -F/3-8 PLANT 2 SNEEt 1M262 JOB NO. 972197-00 COMP NO. DWG NO. 2-81-1M262 Page 13 of 27 12E3 n MATCHLINE SEE SHEET 1M261 AN LIB 1" 1" DUCER 8: RECO 'L'ur. 'ATION FACILITY - S' 10' CEILING 13F3 I 1" • • 1 1/4" ( 18'-11" TYP ELE 1 1/2 CORRIIOR I I 3 I 3" I 2' P" 2" 2" 2" Aft 1 1/2" -9 1 1/2" -j 1 1/411.1 ELECTRICAL SHOP - N18.1 I 12°3 110' CEIL NG 1 1/2" 1 1/2" 1 1" I, /4" 0 4 h1®000 WOMEN'S 1v I I2F4 1 II 120 V V 18'-6" TYP ELEV. ST' aI • MEI'S 1F4) 1{-1,F1 �I1 Et FACILITY COMPON 6" & TEST PART STORAGE NI2 ELEV.- 1"1 1365 • d' .'6' ® a1 fl 2" 1" 1404 I SOUND DEMO... -7570 FACILITY - N4 �= - 16'-Oi TYP ELEV 1404 2 1/2" fTMP 1104 1" 1" 1M263 M514 1 1 4" 1 1 2" T !!;F1'_ = y 1 1/4" 1 1/2 Ir L II IIII r{ 116 . 6' .{ ,b III r IIII II 2" DN TO , tet- I_ I II ANEHOIC REVERBII / Tfi' h FACILITY SEE ) .I ELEV. II II 1M263 M514 Ilij " 1 1/2" o - o-- T- 1 1 4" 1 1 2" 1" 1" III III I I I I 11J 9111 1111 1 1/2" /4" 1 1/2" 1" 1M2631M514 2" 1M263 M514 \ 2" H1 4" ELEV. R' 1CAL LISJfE-NING p ROOM ' 1144.1 • i 0 �1 1/2 1 1/4" i2H/) 1247 1 1" TYPE TEMP. . WAVE GUIDE -1F4/ i3' - N32 • 1" • • 1" CENTRAL +/12LS" 1 17 • •• 1.1 1/2" 1 1/4" 165 1/2" 1 BR. •1" CENTRAL • RECESSED • 'IMAM A Da • CONTROL _FOOM - N32 t_ 12J5 12.,1 ( 1515=15'` • TYP E-tE • 0 H WI E TABLE [°11K3 0 0 2" ANECHOIC }} REV .CILITY -X0'7 0 18'-6" ELEV. 1" DESPATCH OVER" 1" 0 0 1" 1" 0 1 0 1 1/2" 12" 072N �A11/2. TESTING AREA 2" 1146 0 0 1 fz"- • 1 1/4"- -0- -o h 1%2" II ( 1 1G 0 1 1/4" 1 1/2"7 HI TEMP TEST - N31 I 12'07 1 4" F l 12" 0 1 1/2" 0 2 •1107) I 0 MTC 2 -TUBE ROC2c - N30 2 Sqr i2H/) 1247 1 MODEL 2 1" 1 1/2" Imo. 1 1 4" u RO MI6 N30 TKP 2" 2 BENCH IEBENCH EBENCH BENCH r-� 1 1 2" III I T 1;1/2" 1 1/4" 2" ON TO QUIET AIR TEST FACILITY OUIE Ib 'TEST FAIM263 M5.499. I f4"36 1 1 1" 1" TI II I I I I I I I I 1 I I 1" 1/2' 0 1 1/2" 0 1 1/4" rTT PT. MATERIAL TEST CENTER FLOW ROOM - N30 I 114; 2' 1 1 2" K S4 ) 1' 1" 2" 1 1 1" TYP 0 0 0 1" ▪ �(11K7U 18' - NMI t� MINIM S AIRS 13 FIRE PROTECTION SCALE: 1/B"=1'-0" 52 5 ) LEGEND SYM SPRINKLERS MODEL TYPE TEMP. NPT K FAC FINISH o CENTRAL A SSU 165 1/2" 5.6 BR. • CENTRAL GB RECESSED 155 1/2" 5 6 CHR. ► CENTRAL A SSU 212 1/2" 5 6 BR. al' FLEX CONNECTORS GENERAL NOTES 1. THE BOEING TUKWILA FIRE PREVENTION DEPARTMENT SHALL BE NOTIFIED 24 HOURS IN ADVANCE OF ALL VALVE CLOSURES, FLUSHING, AND HYDROSTATIC TESTS ON THE FIRE PROTECTION SYSTEM THE MAXIMUM DURATION OF A SYSTEM CLOSURE IS B HOURS 2. A CONTRACTOR'S MATERIAL AND TEST CERTIFICATE WILL BE REQUIRED UPON COMPLETION OF THE TESTING. THE CERTIFICATE MUST BE SIGNED OFF BY THE BOEING TUKWILA FIRE INSPECTOR DEPARTMENT PRIOR TO COMMENCING ADDITIONAL WORK ON THE FIRE PROTECTION SYSTEM. 3. FIRE PROTECTION PIPING SHOP DRAWINGS SHALL BE SUBMITTED TO BOEING FIRE PROTECTION ENGINEERING AND MUST BE APPROVED BEFORE ANY MODIFICATION TO THE FIRE PROTECTION PIPING SYSTEM BEGINS. 4. REFER TO SPECIFICATIONS FOR MATERIAL REOUIREMENTS 5. HYDROSTATIC TEST: PRESSURE - 225 PSIG, DURATION - 2 HOURS. 6. SEISMIC BRACING SHALL BE INSTALLED IN ACCORDANCE WITH FM STANDARDS. SEE FM DATA SHEETS 2-8, 'EARTHQUAKE PROTECTION FOR WATER-BASED FIRE PROTECTION SYSTEMS' FOR SPECIFIC DETAILS. 7. FIRE SPRINKLER SHOP DRAWINGS SHALL INCLUDE THE SPRINKLER CONTROL VALVE TAG AND LOCATION FOR THE SERVES THE AREA. 8. COORDINATE SPRINKLER HEAD PLACEMENT AND PIPE ROUTING WITH ALL DISCIPLINES, INCLUDING EXISTING MECHANICAL AND ELECTRICAL DISCIPLINES. 18'-8" 9. SYSTEMS ARE ORDINARY HAZARD, PIPE SCHEDULE (30% OVERSIZED MAINS) TYP ELEV. MAX. HEAD SPACING = 130 SQ. FT. PER HEAD. DO cD C CO ❑ REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 {b) City of Tukwila BUILDING DIVISION ( 7 ) 10. INSTALLATION TO CONFORM WITH NFPA #13 AND FACTORY MUTUAL. ALL MATERIAL TO BE NEW, U.L. AND F.M. APPROVED ALL WELDING TO CONFORM WITH AWS D10.9 AND BE PERFORMED IN THE SHOP. CONSTRUCTION NOTES • PROVIDE FIRE SPRINKLER SUPPLY TO RACKS AS SHOWN POINT OF CONNECTION TO EXISTING 4" SPRINKLER MAIN COORDINATE PIPE ROUTING WITH ALL DISCIPLINES AND PROVIDE ADDITIONAL OFFSETS AND SPRINKLERS AS REQUIRED. PROVIDE AUXILIARY DRAINS PER NFPA-13. 2. MODIFY EXISTING FIRE SPRINKLER SYSTEMS IN ACCORDANCE WITH BOEING FIRE PROTECTION ENGINEERING STANDARD D38108 -F, NFPA-13, FM 2-0 AND FM 2-8, APPLICABLE CODES AND BOEING FIRE DEPARTMENT REQUIREMENTS. THE FIRE SPRINKLER CONTRACTOR SHALL PREPARE FIRE SPRINKLER SHOP DRAWINGS AND HYDRAULIC CALCULATIONS IN ACCORDANCE WITH THESE STANDARDS AND SUBMIT TO BOEING FIRE PROTECTION ENGINEERING FOR • MODIFY EXISTING WET PIPE SPRINKLER SYSTEM IN CORRIDOR AREA TO ACCOMMODATE WALL AND CEILING CHANGES BY ARCHITECTURAL. RECEIVED CITY OF TUKWILA NOV 1 2 2013 PERMIT CENTER 90% SUBMITTAL ISSUED FOR PERMIT 2-81 BUILDING KEY PLAN SMI: Mrs O 1,11/ Wood Harbinuer 7009 oath tea NE Suite Teo Bellevue WA 98001 4D5.62t600o wocmurba getcom SYM REVISION A RECORD DRAWING CX RELOCATION - PALLET RACK MOVE CDC RELOCATION - WIRE SHOP RELOCATION J1972197-00 J119760 J119760 BY HGI/KLC WH WH APPROVED DATE REVISION BY APPRO+ED DATE 8.7 01 MDL MDL 09.12.13 10.22.13 g)1_1745FE,ArG® ACCEPTABILITY THIS DESIGN MND/OR SPECIFICATION IS APPROVED -DRAWN K. COLE NATE 07.18.01 7.31.01 S. FR NKUN SUBNRE FIRE PROTECTION CURRENT REVISION .419760 SYMBOL B DATE 10.22.13 APPROVED BY DEPT. DATE CRUNLLN 'CHECKED 9.4.98 APPROVED APPIMED TITLE MECHANICAL MASTER WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 COL. F -L/3-8 PLANT 2 SNEET 1M263 JOB NO. 972197-00 COMP NO. DWG NO. 2-B1-1 M263 Page 14 of 27 CO 15'-0" (LD BLDG. 2-81 BLDG. 2-80 1/2" RL 7/8" RHG 11111 ® ONE �, E '' I/ Ii�'rl�/► 1 1 I I 4"CHWS/R DN 2"HWS/R DN L CCESS DOOR 120/120 INTAKE HOOD FOR AHU 5 & 6 15'-0" =LLt V EL] CSC C UU1-1 9'-0" SEL DETAIL RFM3 M500 m f�1 23'-6 8"TWS T (CA ED)� 4) 8" TWR L J I r (CA EDD 1 I I 1 4" CHWS/R UP 3" CHWS/R N C RFM3 M500 0 Hl1�SEO DFTAIL(� 3 RFM3 M500 DUCTWORK AND HVAC PIPING SCALE: 1/16"=1'-0" 6 (7) l L , REVIEWED FOR CODE COMPLIANCE APPROVED. NOV 2 7 2Q13 City of Tukwila BUILDING DIVISION LEGEND CC HC RL RS RHG COOLING COIL HEATING COL REFRIGERANT LIQUID REFRIGERANT SUCTION REGFRIGERANT HOT GAS GENERAL NOTES 1. INSULATE AND HEAT TRACE CTWS, CTWR, PW, CHWS, CHWR CHWR, HWS & HWR ON THE ROOF OUTSIDE THE HEATED BUILDING ENVELOPE INCLUDING THE AIR HANDLING UNIT VESTIBULE, PER SPECIFICATIONS. 2. SEE MECHANICAL DRAWING 2-81-M1a FOR PENTHOUSE SCHEDULE. 13> AHU-2 SHALL HAVE 3 -WAY CHILLED WATER CONTROL VALVE. REFERENCE DRAWINGS CONSTRUCTION NOTES 90% SUBMITTAL ISSUED FOR PERMIT RECEIVED CITY OF TUKWILA NOV 1,2 2013 PERMIT CENTER Wood Harbinger 3009 mth Ave NE Salt m Rename WA 98004 Aasaa%Amo moodhardngn mm Sal A 8 REWSON RECORD DRAWING RECORD DRAWING CDC RELOCATION — WIRE SHOP RELOCATION 4972197-00 4982190-00 419760 8) HGI/SHS HCl/RB WH APPRENO) DATE rn REV6gl1 ev APPROVED DATE 11 12.99 03.15 01 MBL 102213 ce;iBOWAS e”• ACCEPTABILITY NS DESIGN AND/OR SPECIFICATION IS APPRa9ED APPROVED BY DEPT. DATE WARDELL I� 30.98 CHECNIU 6.NAPIER 5.15.98 SUermE DUCTWORK AND HVAC PIPING CURRENT REVIS0N J#19760 mea B 10.22.13 /ANR 0. F G. RANEK 1.30.98 CHEC6ED G. SPRAGUE 1 6.3.98 APPROVED L COSTELLO 6.3.98 APPROVED R. MCNIESH 6.3.98 TRIS WIRE SHOP RELOCATION TO 2-81 MECHANICAL MASTER BUILDING 2-81 PLANT 2 SHEET RFM3 JOB No. 972197-00 COUP N0. 2-81—RFM3 Page 15 of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e982190-00 419760 BY LS/JIM 401/R8 WH AFFRONT➢ DATE SYN REVIEWED FOR INCE APPROVED COMPLIANCE E® NOV 2 7 2013 City of Tukwila BUILDING DIVISION REVISION BT APPROVED AIR HANDLING UNITS - AHU-6 AND EF -5 1. THE AHU-6 SYSTEM IS BEING CONVERTED FROM A 100% OSA MAKEUP AIR UNIT TO A VARIABLE VOLUME SYSTEM. THE SYSTEM CONSISTS OF AN AIR HANDLING UNIT WITH HEATING AND COOLING WATER COILS, NEW FAN AND VAV TERMINAL UNITS, AND AN EXHAUST/RELIEF FAN (EF -5). I AHU-6 WILL HAVE ITS FAN MOTOR REPLACED WITH A NEW INVERTER DUTY MOTOR AND A NEW VFD TO CONTROL ITS SPEED. EF -5 WILL HAVE ITS FAN MOTOR REPLACED WITH ANEW INVERTER DUTY MOTOR AND A VFD TO CONTROL ITS SPEED. THE SYSTEM WILL OPERATE DURING NORMAL OCCUPIED HOURS. 2. WARM-UP MODE: PLACE THE SYSTEM IN WARM-UP MODE BASED ON AN OPTIMIZED ALGORITHM WHICH COMPARES OUTDOOR AIR TEMPERATURE AND ZONE TEMPERATURE TO DETERMINE THE AMOUNT OF TIME PRIOR TO OCCUPIED MODE REQUIRED TO HEAT THE BUILDING TO OCCUPIED SETPOINT. A. AIR HANDLING UNIT: START THE SUPPLY FAN. MODULATE THE SUPPLY FAN SPEED TO MAINTAIN DUCT STATIC PRESSURE SETPOINT (INITIALLY SET TO 1.0" WC, FINAL TO BE DETERMINED BY TESTING AND BALANCING AGENT). SHUT THE MIXING DAMPERS TO 0 PERCENT OUTDOOR AIR AND 0 PERCENT EXHAUST. DISABLE THE COOLING COIL. MODULATE THE HOT WATER HEATING COIL CONTROL VALVE TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT, (65 DEG F)(ADJ). OPERATE THE SYSTEM IN WARM-UP MODE UNTIL ALL ZONE OCCUPIED HEATING SETPOINTS ARE SATISFIED OR THE SCHEDULED DAY MODE PERIOD BEGINS, WHICHEVER OCCURS FIRST. 3. OCCUPIED MODE: PLACE THE SYSTEM IN OCCUPIED MODE IF SCHEDULED TO BE OCCUPIED. A. AIR HANDLING UNIT, START; THE SUPPLY FAN. MODULATE THE SUPPLY FAN SPEED TO MAINTAIN DUCT STATIC PRESSURE. IN HEATING MODE, MODULATE THE HOT WATER HEATING COIL CONTROL VALVE TO MAINTAIN DISCHARGE AIR TEMPERATURE SETPOINT (SEE DISCHARGE AIR TEMPERATURE SETPOINT RESET) AND OPEN THE OUTDOOR AIR DAMPER TO THE MINIMUM OUTDOOR AIR POSITION (SEE MINIMUM OUTDOOR AIR VOLUME SETPOINT RESET), OPEN THE EXHAUST AIR DAMPER TO 100% AND MODULATE THE RELIEF FAN SPEED TO MAINTAIN MAXIMUM SPACE STATIC PRESSURE AT PLUS 0.05" WATER COLUMN (ADJ). IF jN COOLING MODE AND THE ECONOMIZER CYCLE IS ENABLED, OPEN THE MIXING DAMPERS TO 100 PERCENT OUTDOOR AIR VOLUME, OPEN THE EXHAUST AIR DAMPER TO 100 PERCENT EXHAUST, MODULATE THE RELIEF FAN TO MAINTAIN MAXIMUM SPACE STATIC PRESSURE AT PLUS 0.05" WATER COLUMN (ADJ), AND MODULATE THE COOLING COIL TO MAINTAIN THE DISCHARGE AIR TEMPERATURE SETPOINT. IF IN COOLING MODE AND THE ECONOMIZER CYCLE. IS DISABLED, MODULATE THE MIXING DAMPERS TO MAINTAIN THE MINIMUM OUTDOOR AIR DAMPER POSITION SETPOINT, OPEN THE EXHAUST AIR DAMPER TO 100%, MODULATE THE RELIEF FAN SPEED TO MAINTAIN MAXIMUM SPACE STATIC PRESSURE AT PLUS 0.05" WATER COLUMN (ADJ), AND MODULATE THE COOLING COIL TO MAINTAIN DISCHARGE AIR TEMPERATURE SETPOINT. 4. UNOCCUPIED MODE: PLACE THE SYSTEM IN UNOCCUPIED MODE IF SCHEDULED TO BE UNOCCUPIED. A. AIR HANDLING UNIT: STOP THE SUPPLY AND RELIEF FAN. SHUT MIXING DAMPERS TO 0 PERCENT OUTDOOR AIR. CLOSE THE EXHAUST AIR DAMPER. SHUT THE HOT WATER HEATING VALVE AND DISABLE THE COOLING COIL. 5 TEMPORARY OCCUPANCY MODE: A. AIR HANDLING UNIT: PLACE THE SYSTEM IN TEMPORARY OCCUPANCY MODE IF SCHEDULED TO BE UNOCCUPIED AND ANY TERMINAL UNIT ZONE PUSH BUTTON IS ENGAGED. OPERATE THE SYSTEM THE SAME AS OCCUPIED MODE. AFTER TWO HOURS (ADJ) RESTORE THE SYSTEMtTO UNOCCUPIED MODE. 6. UNOCCUPIED HEATING MODE: PLACE THE SYSTEM IN UNOCCUPIED HEATING MODE IF SCHEDULED TO BE UNOCCUPIED AND THE ZONE TEMPERATURE FALLS BELOW 55 DEG F. OPERATE THE SYSTEM THE SAME AS IN WARM-UP MODE UNTIL THE ZONE TEMPERATURE REACHES 60 DEG F (ADJ). ONCE THE ZONE TEMPERATURE REACHES 60 DEG F, PLACE THE SYSTEM BACK IN UNOCCUPIED MODE. PREVENT THE SYSTEM FROM CYCLING MORE THAN ONCE PER HOUR. 7. DISCHARGE AIR TEMPERATURE SETPOINT RESET: RESET THE DISCHARGE AIR TEMPERATURE SETPOINT (55 DEGREES F TO 65 DEGREES F) (ADJ) IN 2 DEG F (ADJ) INCREMENTS PERIODICALLY (10 MINUTES (ADJ)) TO MAINTAIN THE MOST LIMITING ZONE TEMPERATURE AT ZONE TEMPERATURE SETPOINT BASED ON DAMPER POSITION OF THE TERMINAL UNITS. 8. ECONOMIZER CYCLE: ENABLE THE ECONOMIZER CYCLE IF THE RETURN AIR TEMPERATURE IS 2 DEG F MORE THAN THE OUTDOOR AIR TEMPERATURE. DISABLE THE ECONOMIZER CYCLE IF THE RETURN TEMPERATURE IS LESS THAT THE OUTDOOR AIR TEMPERATURE. 9. SMOKE SHUTDOWN: UPON THE' SENSING OF SMOKE IN THE RETURN AIR STREAM, DISABLE THE SUPPLY AND RELIEF FANS, CLOSE THE OSA AND EXHAUST AIR DAMPERS TO 0 PERCENT. DISABLE THE CONDENSING UNIT AND CLOSE THE HEATING WATER CONTROL VALVE. 10. SAFETIES AND INTERLOCKS A. LOW LIMIT THERMOSTAT LOCATED BETWEEN THE HEATING AND COOLING COIL WILL SHUT DOWN THE AHU AND ALARM ,THE DDC SYSTEM IF THE MIXED AIR TEMPERATURE DROPS BELOW 35 DEG F (ADJUSTABLE). THE LOW LIMIT REQUIRES MANUAL RESET AT THE UNIT. THE HEATING WATER VALVE WILL BE COMMANDED TO 100% IF A LOW TEMPERATURE SITUATION IS DETECTED. B. DUCT HIGH STATIC PRESSURE SWITCH SHALL OVERRIDE THE VFD OUTPUT TO PREVENT OVER PRESSURIZATION OF THE DUCT. C. UPON A POWER LOSS SITUATION ALL AHUS, EFS, CHILLERS, AND PUMPS WILL SHUT DOWN AND THEN STAGE ON IN A SEQUENTIAL AND DELAYED MANNER TO PREVENT EXCESSIVE LOADING. DATE 5.22.98 03.15.01 10.22.13 le;LAFAIEIAW ACCEPTABILITY 11115 DESIGN AND/0R SPECIFICATION 6 APPROVED APPROVED BY DEPT. DATE 0 RECEIVED CITY OF TUKWILA 6. CHILLED WATER SYSTEM I. CHILLED WATER DISTRIBUTION FLOW CONTROL II SYSTEM DESCRIPTION: THIS SYSTEM IS THE CHILLED WATER DISTRIBUTION FOR THE HVAC SYSTEMS IN THE 2-81 BUILDING. THIS SYSTEM CONSISTS OF TWO (2) CENTRIFUGAL PUMPS, WITH VARIABLE FREQUENCY DRIVES (VSD), SIZED AT 100% CAPACITY EACH AND ARRANGED IN PARALLEL. THIS SYSTEM WILL BE ARRANGED AS A TERTIARY LOOP DECOUPLED, WITH A COMMON BYPASS LINE, FROM THE SECONDARY CHW SERVICE. THE SECONDARY CHW LOOP PROVIDES CHW SERVICE TO THE BUILDING FROM THE 2-85 CUB VIA THE SOUTH YARD UTILIDOR. THIS SYSTEM IS CONTROLLED BY THE DDC CMCS. A. TERTIARY LOOP: THE TERTIARY LOOP WILL FUNCTION WHENEVER AN AHU CHILLED WATER VALVE CALLS FOR COOLING IS OPERATIONAL. THE PUMPS P-5 AND P-6 WILL BE SWITCHED BASED UPON RUN TIME. ONCE A MONTH THE PUMP WITH THE MOST RUN TIME WILL SHUT OFF AND THE PUMP WITH THE LEAST RUN TIME WILL START VIA THE DDC SYSTEM. IF A PUMP 'FAULT' INDICATION IS RECEIVED FROM THE VFD OR IF THE SYSTEM DIFFERENTIAL DROPS BELOW 1 PSID (SET AS REQUIRED) FOR 10 MINUTES THEN ENABLE THE LAG PUMP. THE SECONDARY PUMPS VFD WILL MODULATE TO MAINTAIN SYSTEM SUPPLY PRESSURE DOWNSTREAM AS SENSED BY THE DIFFERENTIAL PRESSURE SENSOR. THE DDC SYSTEM WILL POLL THE TRANSMITTER FOR THE MINIMUM DIFFERENTIAL. THIS MINIMUM WILL BE USED FOR CONTROLLING THE SECONDARY PUMPS. TO PREVENT DEAD HEAD OF THE PUMPS AND TO MAINTAIN CHILLED WATER CIRCULATION, AHU-2 WILL BE PROVIDED WITH A 3 -WAY VALVE. SECONDARY CHILLED WATER SUPPLY IS MONITORED FOR FLOW AND TEMPERATURE. THE SECONDARY CHILLED WATER RETURN IS MONITORED FOR TEMPERATURE. CHILLED WATER SUPPLY TEMPERATURE CONTROL: A. CHILLED WATER SUPPLY TEMPERATURE SET -POINT TO BE RESET BY THE DDC SYSTEM. THE SET -POINT WILL BE RESET BASED ON AHU MAX VALVE POSITION AND LOAD. THE CHILLED WATER VALVES WILL BE MONITORED FOR MAXIMUM POSITION EVERY 5 MINUTES. IF THE MAXIMUM VALVE POSITION IS 100% THEN THE TEMPERATURE SET -POINT WILL BE ADJUSTED DOWN BY 0.5 DEG F. IF THE MAXIMUM VALVE POSITION IS LESS THAN 80% THEN THE SET -POINT WILL BE ADJUSTED UP BY 0.5 DEG F. B. THE CMCS (DDC) SHALL MODULATE THE TWO-WAY CHWR CONTROL VALVE TO MAINTAIN CHWS TEMPERATURE SET -POINT. HOT WATER HEATING SYSTEM 1, THE HOT WATER HEATING SYSTEM CONSISTS OF A COWERTER (HEX -1, SHELL & TUBE HEAT EXCHANGER), HOT WATER HEATING PUMPS (P-9 AND P-10) AND THE HOT WATER HEATING PIPING LOOP EXTENDING TO FAN TERMINAL UNITS, HEATING COILS IN NR HANDLING UNITS , UNIT HEATERS AND HOT WATER FAN COIL UNITS. SYSTEM TO OPERATE ON A CALL FOR HEATING. ONE HOT WATER HEATING PUMP IS A STANDBY PUMP WITH 100% SYSTEM REDUNDANCY. 2. ONE PUMP IS DESIGNATED AS LEAD AND THE SECOND PUMP IS LAG. ONCE A MONTH THE PUMPS WILL BE SWITCHED BASED UPON THE LEAST RUN TIME, TO PROVIDE EQUAL SERVICE OF THE PUMPS. THE PUMPS WILL BE MONITORED FOR STATUS AND FAULT VLA THE VARIABLE FREQUENCY DRIVE (VFD). UPON LOSS OF STATUS OR FAULT INDICATION FROM THE LEAD PUMP THE LAG PUMP WILL BE STARTED AUTOMATICALLY VIA THE DDC SYSTEM. 3. A DIFFERENTIAL PRESSURE TRANSMITTER, LOCATED ON THE 2ND FLOOR, WILL BE USED TO CONTROL THE SPEED OF THE HEATING WATER VFD PUMPING SYSTEM. DIFFERENTIAL PRESSURE SET POINT IS RESET BASED ON MAXIMUM VALVE POSITION. 4. HEATING SUPPLY WATER TEMPERATURE WILL BE MAINTAINED VIA 1/3 AND 2/3 HEATING VALVE SERVING HEX -1. THE STEAM VALVES WILL REMAIN CLOSED (SPRING RETURN CLOSED) WHEN BOTH PUMP P-9 AND P-10 ARE OFF. UPON PROOF OF OPERATION OF ONE PUMP THE STEAM VALVES WILL BE STAGED TO MAINTAIN DISCHARGE TEMPERATURE SET -POINT. OPENING CLOSING 5 NOV 1,2 2013 PERMIT CENTER DRAWN H. WARDELL 2.4.98 DEMAND 1/3 VALVF 2/3 VALVE DEMAND 1/3 VALVE 2/3 VALVE A) 0% 0% 0% 0% B) 33% 33% 33% 25% 75% 0% C) 34% 34% 34% 75% 257. 257. 0) 100% 100% 100% 100% 100% 100% 0% 0% THE HEATING SUPPLY WATER TEMPERATURE WILL BE RESET FROM 140 DEG F TO 180 DEG F BASED UPON VALVE POSITION. THE TERMINAL UNIT VALVES AND AIR HANDLING UNIT HEATING VALVES WILL BE SAMPLED EVERY FIVE MINUTES FOR THE MAXIMUM VALVE POSITION. THIS MAXIMUM POSITION WILL RESET THE SET -POINT EVERY 5 MINUTES BY .05 PSI. IF THE MAXIMUM IS GREATER THAN 95% THE SET -POINT WILL BE RAISED, IF THE MAXIMUM IS LESS THAN 80% THAN THE SET -POINT WILL BE LOWERED. DURING LOW LOAD CONDITIONS THE VFD PUMP WILL BE OPERATING AT A MINIMUM FREQUENCY. ONE BY-PASS VALVE LOCATED IN MECHANICAL ROOM ADJUSTED TO CONTROL DIFFERENTIAL PRESSURE AT MIN FREQUENCY. THIS WILL MAINTAIN A MINIMUM FLOW REGARDLESS OF HEATING LOAD. LANDIS & STAEFA BOEING 2-81 BLDG. 90% SUBMITTAL ISSUED FOR PERMIT SUBTITLE HVAC CONTROL SEQUENCES 101 ��IIi1V- Wood Harbinger CURRENT REVISION J#19760 SYMBOL rag Nath Mt NE. Sulix ADD Bellevue WA 9Boo4 4.54.a60oo NOOEIBTWngeT.OM1 DATE 10.22.13 IWWNTLN J. GAVINO CHECKED G. SPRAGUE 2.4.98 6.3.98 L CMVED OSTELLO APPROVED 6.8.98 TITLE WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 MECHANICAL MASTER PLANT 2 SHEET M310 AM ml 972197-00 DNC NO. 2-81-M310 Page 16 of 27 1183 740 CFM /� 1384 790 CFM FT 1 1181 2745 CFM /� i 1 1183 1284' 740 CFM 510 CFM n/� 1,zac) 1,zg 0 CFM MIN 43,025 CFM MAX 3090 CFM MIN 43025 CFM MAX 9310 CFM MIN OSA 52385 CFM MAX ROOF LINE ROOF LINE L 1-07 L� 13C3 11C3 11D3 2810 CFM 2260 CFM 700 CFM 12G7 11F7 12E7 2480 CFM 1400 CFM 2480 CFM 14E5 550 CFM 1070 CFM 13E4 900 CFM 11E5 & 12E5 170 CFM t o � 1 P 13E1 ' 13C3 2810 CFM 500 CFM �FT 17400 CFM MIN 52335 CFM MAX L-� FT n 1�0 1 14G4 11H4 12G3 12K1 11K3 1310 CFM 900 CFM 530 CFM 550 CFM 1740 CFM 12J5 11DB18 1830 CFM 1300 CFM w 11DB19 700 CFM / 7 110B18 1 110818 1270 CFM 3205 CFM FT L1 345 CFM 12DA16 130 CFM 11DA18 120 CFM 11018 n+ /-n-A Fr tlip L11 1 1 ST FLOOR PROCESS AREA Fn klj tv14 13F3 13G5 11G4 12G5 11G5 1250 CFM 1635 CFM 275 CFM 1360 CFM 2310 CFM 11H6 11G7 1620 CFM 780 CFM 11J0 5000 CFM SVM ROOF 1;4 REVOON 7600 CFM MAX 1910 CFM MIN POC SA -0- 1,±21 A—_ 1 EA FROM PLENUM 5700 CFM DA L1 132 450 CFM 1700 CFM v MEZZ 7800 CFM MAX 1910 CFM MIN RA FROM PLENUM 1160 CFM MIN EA 7085 CFM MAX — DA RECORD DRAWING 4972197-00 HGI/SHS 11.12.99 CX RELOCATION - WIRE SHOP RELOCATION 419760 WH MBL 10.22.13 el___AVAPEZAW° 3000 CFM MIN 8385 CFM MAX v MEZZ 1160 CFM MIN 7085 CFM MAX ACCEPTABILITY TUG DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BV DEPT. DATE DRAWN R. TOPNESS 'CHEERED S. FRANKLIN 'LNWNLEN G. FRAMER CHECKED G. SPRAGUE DATE 11.3.97 3000 CFM MIN 8385 CFM MAX 1620 CFM 1230 CFM 1230 CFM ,FT 1 1840 CFM 12H7 1 190 CFM 95 CFM 165IEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION 1845 CFM 90% SUBMITTAL ISSUED FOR PERMIT 3.30.98 HVAC FLOW DIAGRAM 11T2 CFM REdE VED CITY OF TUKWILA NOV 1 '2 2013 PERMIT CENTER Itu il�lllllll Wood Harbinger COMM REVISION Jll19760 SYMeDL 3no9 Lath tee NE. Suite 100 Bellevue WA gimp 405.608.6000 M006INfbIReeENO DATE 10.22.13 11.3.97 6.3.98 APPIUNED L GOSTELLO 6.3.98 APPROVED R. MCNIESH 6.3.98 IDLE WIRE SHOP RELOCATION TO 2-81 MECHANICAL MASTER BUILDING 2-81 PLANT 2 SHEET M311 JOB NO. 972197-00 COMP NO DWG N0. 2-81-M311 Page 17 of 27 2X1" SVM 3/4" CHWS/CHWR BY COLUMN F-4 1" CHWS/R BY COLUMN C-1 5 MICRON FILTER 1"x3/4" 1"x3/4" 1"x3/4" 1'x3/4" 1 FIRST FLOOR SECOND FLOOR 8"x4" 4"X3" 2" CHWR c REVISION RECORD DRAWING J4972197-00 A CDC RELOCATION - WIRE SHOP RELOCATION J.19760 DY HGI/SHS WH APPROVED DATE L) U 4"x2" 4"x1" U 4" CHWR 2"xl" 4"X1" 1" VALVES & CAPS FOR FUTURE CONN. (TYP 3) T T re- re - 2"X1" U, U Tr U SVM REVISION DY APPROVED DATE 11.12.99 TIBC 10.22.13 6"X4" 6" CHWS 6" CHWR U 4" CC U CHILLED WATER - PIPING DIAGRAM II 8" CHWS 8" CHWR 8"x6" _{› 3" CHWS 6"x4" fD 3" CHWR 6"x4" ACCEPTABILITY TAO DESIGN AND/OR SPECIFICATION S APPROVED APPROVED BY DEPT. DATE DRAWN G. KREWIN CHWS \ 2-80-M321 \ 8" CHWR 2-80-M321 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION DATE- 2 ATE2 3.98 24.98 S.FRANKLIN /1.N4WLLN E. YOOSEFIAN POC = POINT OF CONNECTION 90% SUBMITTAL ISSUED FOR PERMIT SUBTITLE CHILLED WATER PIPING DIAGRAM GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA NOV 1 2013 PERMIT CENTER III Wood Harbinger CURRENT REVISION 419760 SYMBOL A WON Ruh AVe NE. Suite m Bellevue WA 98000 425.64.6°0o w00Ehardngecmm DATE 10.22.13 CHECKo G. SPRAGUE L PROWDLLO ED - R. MC R. MCNIESH 2 4.98 6 3.98 6 3.98 6 3.98 TITLE MECHANICAL MASTER WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 PLANT 2 M319 .WB N0. 972197-00 COMP ND. DOG N0. 2-81-M319 Page 18 of 27 Mir! 1n/TI /In i1 3/4" 1.2 GPM 3/4" 3/4"x3/4" 2"x3/4" 3/4" 3"x3/4" 2"x3/4" 2"x3/4" 3/4"x3/4" 3"x3/4" 2"x1" 2"x3/4" (t) a 3"x3/4" 3/4" 2"x3/4" 3"x3/4" 3"xl" DC x 3/4" 2' HWR HWS 3" 3/4" 3"x3/4" 2"x1 1/2'—\b LEGEND 1 1/2"x1" 1 1/2"x3/4" 1 1/2" 3"x1 1/2" 1" VALVED & CAP FUTURE CONNECTIONS TYP. 3 2"x1 3'x3/4 3" HWS 3" HWR / FROM \ 2-81-M320 \ 2-81%320 > 3"x3/4" 3/4" 1"x3/ 3/4" 1= 3"x3/4" 1-11- 1"x3/4" 1 1/2"x1" 1 1/2"x 3"x3/4" HQ - 1 o -1 1/2"x3/4" 1 "x3/4" 101 3/4" 0.9 GPM 1 1/2" 3"x1 1/2 3"x2" FT 1-114 3.75 GPM 1 3/4" 3"x3/4' 2"x3/4" 3"x3/4"" 4-2"x3/4" 3"x3/4 2"x3/4" �% 3"x3/4=- 1 2"x3/4" /� 3"x3/4J— L 2"x3/4" 3/4" 1-0 3.0 GPM 3"x3/4 11) 1"x3/4" 3/4" 3"x3/4" 3/4"F 3 3 x x 2"x3/4" z"x1 1/2" I I I IWR 2"x3/4" 3' 3"x3/4" 1/2"x3/4" 14) 1 1/2"x3/4" `3"x3/4" 1 1/2 x3/4" 3"x3/4"" 3"x3/4J 1 L(- -191 3/4" 3/4" 3/4" 3/4' -60 3/4' 3/4" 3/4" 2.0 GPM n 2.0 GPM 3.0 GPM DUCTWORK SCALE: 1/8"=1'-0" 4.0 GPM 4.0 GPM O 3/4" GENERAL NOTES REFERENCE DRAWINGS REVIEWED F APPROVED FOR COMPLIANCE ROVED NOV 2 7 2013 BUILDING pIVISION CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA NOV 1 2 2013 PERMIT CENTER 90% SUBMITTAL ISSUED FOR PERMIT 11;ii11 Wood Harbinger pop urth PAR NE Suite m Elegem o WA 98x04 425428.6OOD wmARarthgetmm SYM A REVISION RECORD DRAWING Jj972197-00 CDC RELOCATION — WIRE SHOP RELOCATION JI19760 ErE HCI/SHS WH APPROAED DATE SYM REVISION FR APPROVED DATE 11.12.99 881. 10.22.13 g)LArgerrAw ACCEPTABILITY This DESIGN AND/OR SPECIFICATION 6 APPROVED APPROVED BY DEPT. DATE DRAWN SIN S. FRANKUN DATE 3.12.98 5.18.98 SUBTR E FIRST FLOOR HEATING WATER PIPING DIAGRAM EYOOSEFIAN ZNLCKED G. SPRAGUE 3.12.98 6.3.98 APPROVED L COSTELLO 6.3.98 APPROVED R. MCNIESH 6.3.98 TITLE MECHANICAL MASTER WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 PLANT 2 CURRENT REVISION 4/ 19760 s11EET NO. M321 JOB SYMBOL A DATE 10.22.13 972197-00 COMP N0. DWS NO. 2-81—M321 Page 190127 EXHAUST FAN EF—OS `\ // REFERENCE TO OUTDOORS WDM601 • �W r% CSR -05 PDS601 SPACE DIFFERENTIAL PRESSURE PROOF ALARM START SPEED DAMPER END "A".05PRF POSITION SWITCH 8.4 "A"=PL2.081.RFE04.XFN AI DIFFERENTIAL PRESSURE "A"=PL2.0B1.1MC06.SFN "B"=PL2.0B1.1MDO6.SFN OSA DAMPER POSITION ND SWITCH "C".O6ES 4.3 5.1 "C"=PL2.0B1.RFE05.SFN "D"=PL2.081.1SD06.SFN AO DAMPER POSITION DI END SWITCH "E"=PL2.081.1 MC07.XFN HWS t-- DI FILTER "A".O6FLTR 8.1 TCV601 HEAT COIL A".06HCV 27.2 AHU-6 SCALE: 1/8"=1'-0—O " TCV602 CWS TSL601 • COOLING COIL FREEZE "A".06CCV "A".O6LTD 27.1 6.2 CSR601 X E DO m ALARM START SPEED A".06SS 3.1 REVIEVVE CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION PROO "A".06 4.4 O s0 > 000 11601 M327 1E212 11602 M327 1E212 ® AI DUCT DISCH TEMP STATIC "D".06DAT PRESSURE 24.1 M327 E517 ROOM TEMP "B".06IRT 24.2 ITEM SEQUENCE OF OPERATIONS 1. REFER TO SHEET M310 FOR AHU-6 AND EF -05 SEQUENCE OF OPERATIONS. GENERAL NOTES: 1. ALL POINTS SHOWN LAND IN MBC 274 LTD CUT—OUT RELAY LOCATED IN SUPPLY FAN DISCONNECT 13 > SAFETIES HARD—WIRED TO SUPPLY FAN 4 > DAMPER LOCATED AT GRID E,5 ON ROOF TOP 5 > INTERPOSING RELAY FOR EXHAUST FAN LOCATED AT DISCONNECT REFERENCE DRAWINGS: 2-81—E517 2-81—RFE210 2-81—E521 2-81-1E212 CONSTRUCTION v NOTES NEW VFD. PROVIDE ASSOCIATED CONTROLS. REFER TO RFM12 AND M1M456 FOR LOCATIONS. COORDINATE WITH ELECTRICAL. PROVIDE NEW CONTROL DAMPER AND ASSOCIATED CONTROLS. PROVIDE NEW CONTROL DEVICE AND ASSOCIATED CONTROLS. ® REPLACE MOTOR PER SCHEDULE. MATERIAL LIST PART NUMBER SUPPLIER RECEIVED CITY OF TUKWI NOV 1 2 2013 PERMIT CENTER DMR6011 H908 GCA161.1P FOS 601 141 US/4 V RIS CURRENT SENSING RELAY LANDIS . STALFA, 24VAC SR 0-10VDC MOD LANDIS & SIAEFA, U.5-1' PRESSURE SWIIUH TCV 6 1 296-03214 TCV 6 2 296-03197 TSL 6 1 134 1504 SIZE 1.5: CV 25, 40 GPM, 2.6 DROP SIZE 2.0 , CV 40, 88 GPM 4.8 DROP LANDIS & STAEFA DPST MANUA RESET TT 601 TT 602 544 344 LANUIS & SIALFA, 24 RIGID AVERAGING 544 300 LANDIS & SIAEFA, ROOM SENSOR CSR -05 HROO CSR -09 HB00 uFR15 EURRENT SENSING RELAY 90% SUBMITTAL ISSUED FOR PERMIT IU lig\ Wood Harbinger RTO9 Tuth A•e NE. SMITL• L00 Bene me WA 99004 4a 6000 w0Comad Kecmm REVISCW AS -BUILT J/972197-00 CDC RELOCATION - WIRE SHOP RELOCATION J119760 BY ASC WH APPRO+ED 1P NEIL MTE 06.23.99 10.22.13 SYM REVISION 8f APPROVED DATE ce:LAFAIEIAW ACCEPTABILITY 1116 DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN J. WEGUNSKI CHECKED DATE 04.09.98 AHU-6 P&ID CURRENT REVISION 419760 SYMBOL A DATE 10.22.13 APPROVED BY DEPT. DATE J. WEG U J. EGUNSKI CHECKED G. SPRAGUE 04.09.98 06.03.98 ROVED L. COSTELLO 06.03.98 APPROVED TULE WIRE SHOP RELOCATION TO 2-81 MECHANICAL MASTER BUILDING 2-81 s'EET M327 JOB NO. 972197-00 COMP NO. PLANT 2 OWE NO. 2-81—M327 Page 20 0127 TC101 DDC TERMINAL CONTROLLER ALL SWITCH DAMPER ROOM TEMP LABEL: "FAN TERMINAL UNIT ON/OFF SWITCH. TURN SWTICH TO OFF DURING TESTS CRITICAL TO SOUND." roTi VI AI SW118 1---->E1SW121 SW123 DM102 EXHAUST DAMPER E TT101 AIR FLOW DAMPER Fl Vol START DM101 DDC TERMINAL CONTROLLER START L/////// FAN TYPICAL SERIES FAN POWERED BOX WITH HOT WATER REHEAT HEAT COIL TCV101 TCV102 HEATING COIL COOLING COIL DISCH TEMP ROOM TEMP HEATING COIL TYPICAL CABINET HEATER OT mos COOLING COIL AIR FLOW DAMPER WI PTI C`�IFATI H I I DM102 DM TC102 DDC TERMINAL CONTROLLER ROOM TEMP TT102 J REVIEWED CODE COMPLIANCE OMLIACE APPROVED { NOV 2 ?, 2013 of Tukwila City DIVISION TYPICAL VAV COOLING ONLY TC103 DDC TERMINAL CONTROLLER START HEAT COIL ROOM TEMP AI RECEIVED CIITY OF TUKWILA NOV 12 2013 PERMIT CENTER - "A" = PL2.081.1 SGO2 "B" = PL2.081.1SJO2 CO OUTSIDE DMPR CO LEVEL COOAD "A".COALEV 13.1 32.1 AI "C" = PL2.081.RFE04.XFN CO LEVEL "B".COBLEV 32.2 UNIT SWITCH START, "B".06WS "C".06SS 8.3 11.1 I PROOF "C".06SS 8.2 DM105 DM106 DM107 DM108 CARBON MONOXIDE METER CO -1 CARBON MONOXIDE METER CO -2 LOCATE METERS 5' ABOVE FLOOR MANUAL START M3301E516 TERMINAL EQUIPMENT P&ID SCALE: 1/8"=1'-0" TCV104 ITEM HEATING COIL TYPICAL UNIT HEATER MATERIAL LIST OTY PART NUMBER SUPPLIER M330 E519 M330 E519 O SERIES FAN PO ERED TERMINAL UNIT OPERATION 1. THE DDC SYSTEM SHALL CONTROL THE OPERATION OF THE FAN, VOLUME OF PRIMARY AIR AND THE HOT WATER REHEAT COIL IN THE TERMINAL UNITS TO MAINTAIN THE HEATING AND COOLING SET -POINTS AT THE ROOM TEMPERATURE SENSOR. THE FAN SHALL RUN DURING THE OCCUPIED PERIOD, NIGHT OVERRIDE AND NIGHT LOW LIMIT MODE. THE ROOMS WILL HAVE ADJUSTABLE SET -POINTS BY THE OCCUPANTS. THE SET -POINTS WILL BE COMMANDABLE THROUGH THE DDC SYSTEM. 2. UNOCCUPIED PERIODS, NIGHT OVERRIDE. A PUSH BUTTON AT EACH THERMOSTAT SHALL ENABLE THE LOCAL FAN AND HEATING COIL FOR 2 HOURS (ADJUSTABLE) TO MAINTAIN ROOM TEMPERATURE. THE AHU WILL BE STARTED DURING THIS MODE. FOR EACH AHU ZONE ONE THERMOSTAT WILL BE DESIGNATED FOR NIGHT OVERRIDE. IF THIS UNIT IS ENERGIZED THE AHU AND ALL TERMINAL UNITS WILL BE STARTED. 3. UNOCCUPIED PERIOD, NIGHT LOW LIMIT. THE LOCAL FAN WILL BE STARTED AND THE HEATING COIL WILL MODULATE TO MAINTAIN ROOM TEMPERATURE. AHU WILL REMAIN OFF. 4. ALL THE FAN POWERED TERMINAL UNITS SHALL BE STARTED PRIOR TO STARTING THE CENTRAL AHU TO ENSURE PROPER ROTATION OF SERIES FANS. 5. AIR SHUT OFF_ SWITCH - IF THE WALL MOUNTED AIR SHUT OFF SWITCH IS IN THE "ON" POSITION, TERMINAL BOX CONTROL OPERATES AS DESCRIBED ABOVE. IF THE SWITCH IS IN THE "1 " PO MON, THE T RMINAL BO FAN WILL SHUT OFF AND THE CONTROL DAMPER WILL CLOSE COMPUTER ROOM UNIT MONITORING 1. THE DDC SYSTEM SHALL ALARM ROOM TEMPERATURE SENSORS FOR FT -2-59 SERVING ROOM 22C4 AND F1-2-37 ROOM 22DB22 IF THE TEMPERATURE IN EITHER ROOM EXCEEDS 78 DEGF. VAV TERMINAL UNIT OPERATION 1. THE DDC SYSTEM SHALL CONTROL THE OPERATION OF THE AIR VOLUME DAMPER IN THE TERMINAL UNITS TO MAINTAIN THE COOLING SET -POINT AT THE ROOM EMPERATURE SENSOR. THE UNIT SHALL HAVE AN OCCUPIED AND UNOCCUPIED SET -POINT FOR TEMPERATURE AND AIR FLOW. THE ROOMS WILL HAVE ADJUSTABLE SET -POINTS BY THE OCCUPANTS. THE SET -POINTS WILL BE COMMANDABLE THROUGH THE DDC SYSTEM. 2. UNOCCUPIED PERIODS, NIGHT OVERRIDE. A PUSH BUTTON AT EACH THERMOSTAT WILL BRING ON THE RESPECTIVE AHU FOR 2 HOURS (ADJUSTABLE). UNIT HEATERS 1. THE DDC SYSTEM SHALL CONTROL THE FAN AND HEATING WATER VALVE TO MAINTAIN ROOM TEMPERATURE. UPON A CALL FOR HEATING THE FAN SHALL BE ENABLED AND THE HEATING WATER VALVE WILL BE MODULATED TO MAINTAIN ROOM TEMPERATURE 70 DEGF (ADJ.). 2. UNOCCUPIED MODE: THE UNIT HEATER WILL CONTROL TO MAINTAIN 60 DEGF. 3. NIGHT OVERRIDE: A PUSH BUTTON AT EACH THERMOSTAT WILL RETURN THE UNIT TO THE DAY SETPOINT FOR 2 HOURS (ADJUSTABLE). FAN COIL UNIT FCU -1 1. FCU -1-01 SERVES THE ELECTRICAL ROOM. THE DDC SYSTEM SHALL CONTROL THE SUPPLY FAN AND CHILLED WATER VALVE TO MAINTAIN ROOM TEMPERATURE. UPON A CALL FOR COOLING THE FAN SHALL BE ENABLED AND THE COOLING WATER VALVE WILL BE MODULATED TO MAINTAIN ROOM TEMPERATURE. CABINET HEATERS 1. THE CABINET HEATERS SHALL BE A PACKAGED UNIT WITH NO DDC INTERFACE. A LINE VOLTAGE THERMOSTAT OPENS THE VALVE AND RUNS THE FAN WHEN THE ROOM TEMPERATURE FALLS BELOW 60 DEGF. VALVE CLOSES AND FAN SHUTS DOWN WHEN THE TEMPERATURE RISES ABOVE 62 DEGF. CARBON MONOXIDE MONITORING 1. THE CO METERS MONITOR THE CO LEVEL IN THE SPACE. IF EITHER METER DETECTS A HIGH CO LEVEL, THE DAMPERS WILL OPEN AND THE FAN WILL START. GENERAL NOTES 1 > TYPICAL OF 3: FT -1-18, FT -1-21, F1-1-23 ONLY. TYPICAL OF 1: FT -1-23 ONLY. I 3 > INTERPOSING RELAY FOR EXHAUST FAN LOCATED AT DISCONNECT 14 > INTERPOSING RELAY FOR EXHAUST FAN LOCATED AT MCC REFERENCE DRAWINGS 2-81-E516 2-81-1E210 2-81-1E213 2-81-2E211 2-81-2E215 2-81-E519 2-81-1E211 2-81-1E215 2-81-2E212 2-81-RFE210 2-81-E536 2-81-1E212 2-81-2E210 2-81-2E213 2-81-E538 CONSTRUCTION NOTES PROVIDE NEW CONTROLS FOR NEW TERMINAL BOXES AS SHOWN ON 1M12. DEMO EXISTING CONTROLS FOR EXISTING BOXES BEING REMOVED ON 1M12R. CS 2 R�STAEEFgA. DM 101-07 95 34900100 DAMPER DM 102 349 LA�ApNNNDDDI$$S g& gACTUAATOR R DM 105-108 g1 GCA121..10 1P L NDIS c8 SIAEFA, DAMPERR ACIUAION T-106 2 134-1086 LANDISDD& STAEFA, LLIyIgqNE TATE IC US 540 100 V C�VQ�OL NRR R TC 103-104 ! 540 110 LANDIS & STAFFA. CONDITION CONTROLLER TCV 101 2 VMP42.09I82 LANDIS &STAEFA, GPM .5 5.0 PD TCV 102 2 VMP42.10 2 SOS82 LANDIS & SIAEhA GPM .� 5.0 PD TCV 103 2 VV�MpPy42.11 2 S0SSg8�2 LANDIS & STAEFA GPM 1.4 S.0# PD TCV 104 2 $ GPM 5.0 PD TCV 105 2 VVI4322O4 . 50182 LANDIS & STAEFA. GPM 15. 5.0# P TCV 106 3 MTF17 15 IANDIS & STAFFA 7ONF VALVE 1/2"NPT TCV 107 1 MTE12.15 IANOIC k STAFFA, 7ONF VAI VF 1/7"NPT TCV 105 1 MTE12 15 LANDIS & STAFFA. 70NE VALVE 1/2"NPT TT 101-104 112 540 670A LANDIS & STAEFA. 101( FHd ROOM SENSOR TT 105 2 535 741 LANDIS & STAEFA. SINGLE DOINT 100K OHM CO 1-2 2 CM -2B MACURCO INC. CARBON MONOXIDE MONITOR 90% SUBMITTAL ISSUED FOR PERMIT T/) Wood Harbinmer ;on Lath Are NE Sum lop BeUeLTre WA 9813o4 4asaa6eouo Kood aHlNQencom BOA A REVISION AS -BUILT J/972197 CX RELOCATION - WIRE SHOP RELOCATION .1119760 BI ASC WH APPROVED TP NBL DATE STU REVSION BY APPROVED DATE 06.23.99 10.22.13 gifirLIE7AW • ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN J. WEGUNSM OTIORED DALE 04.09.98 SUBTITLE TERMINAL EQUIPMENT P&ID CURRENT REVISION Jj)19760 SYYBOL A DATE 10.22.13 J. WEGLINSKI CHECKED G. SPRAGUE APPROVED L. COSTELLO APPROVED 04.09.98 06.03.98 06.03.98 TITLE MECHANICAL MASTER WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 PLANT 2 sHEu M330 JOB NO. 972197-00 COUP NO. DNS NO. 2-81-M330 Page 21 of 27 1 1%2'V 2"V \1 5' n 3/4" .CW HW CAPPED (TYP) 2" SAN UP W 1 1/2" CAPPED (TYP) 4"FCO —p 3/4 WHa1❑ 2"V n O C ❑ ❑ C J r1 .3"V, UP TO ROOF r 2" CONDENSATE 3 2"UP ;> TO F TRAP PRIMER 2" UP TO FD 2'V V A 1/2"CW 2" SAN UP 1 1/2v CAPPED (TYP)-� 0 0 0 z a N 4) 2" SAN DN 2"SAN TRAP PRIMER 1/2"Cw 1/2" CW " SAN UP 1 /2"CW / -1/2"HW HWC 1 1/4" oft FCO CAPPED (TYP) 2v 3/4"HW [* 2" AIR GAP FITTING Q1 1/2"HW 1 1/2"CW 1/2"CW 1 1/2"V I PLUMBING PARTIAL PLAN ( SCALE: 1/4" = 1.-0" .1 M454 1M112 REVIEWED FOR APPROVED NOV 2 7 2013 HWC 1 1/2" 1 1/4" 3V CW_.. H 2 U I��t T- N "- DG J+U3 MASTER City of Tukwila BUILDING DIVISION RECEIVED CITY OFT NOV1 2013 P► PERMIT CENTER SHUT -OF VALVES (6) LEGEND _R_ REFRIGERANT LINE BY KITCHEN EQUIPMENT CONTRACTOR 1/2" CW +72 32 L KITCHEN EQUIPMENT TO BE SERVED (SEE 2-81-A360 FOR SCHEDULE ROUGH -IN ELEV. (ABOVE FLOOR) PIPE SIZE AND COMMODITY GENERAL NOTES 1. FOR CONTINUATION OF PIPING, SEE SHT 1M112. 2 > PROVIDE HOT AND COLD WATER FREEZEPROOF HOSE BIB. 3 > HOSE REEL. NOT USED 5 > NOT USED 1 6 > NOT USED LL% NOT USED I B > WATER HAMMER ARRESTER WAH-A. 7 90% SUBMITTAL ISSUED FOR PERMIT REFERENCE DRAWINGS 1. SEE DWG. 2-81-A460 FOR EQUIPMENT ITEM NUMBERS. 2. SEE DWG. 2-81-A360 AND A361 FOR EQUIPMENT SCHEDULE. CONSTRUCTION NOTES C> LOCATE 2" AIR GAP FITTING AT CEILING SPACE.. SLOPE PIPE TOWARDS DIRECTION OF FLOW AT 1/4" PER FT. POINT OF CONNECTION TO EXISTING RISER AT CEILING SPACE. FIELD VERIFY EXACT LOCATION. POINT OF CONNECTION TO EXISTING 2"SAN AT CEILING SPACE. TERMINATE 2"CONDENSATE DRAIN AT AIR GAP FITTING. PROVIDE CONNECTION TO 2" SANITARY SEWER WITH AIR GAP FITTING. POINT OF CONNECTION TO EXISTING 2"V AT CEILING SPACE. ROUTE 2"CONDENSATE AND 1"CU THRU EXISTING BEAM PIPE PENETRATION. FIELD VERIFY EXACT LOCATION. MAKE NECESSARY ADJUSTMENT AS REQUIRED. O I f/ 'MN Wood Harbinuer 3009 ssrth Awe NE. Suite Loo Be r e WA 98000 WDOBIR16IRgeT.3001 SYM REVISW A RECORD DRAWING 4972197-00 INSTALL ICE MAKER J1585793-00 LAPTOP HOTELING 10113884-50 CCC RELOCATION - WIRE SHOP RELOCATION JI19760 BY HGI/SHS WDB WDB WH APPROVED DATE SYM BY APPROVED DATE 11.12.99 02.28.08 1.12.12 MBL 10.22.13 1 ACCEPTABILITY T O DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN U. HOLT CHECKED S. FRANKLIN PANLJNEtN G. FRANEK DATE 1.10.98 3.30.98 SUBTITLE ENLARGED PLUMBING PLAN CURRENT REVISION 4119760 SYMBOL C DATE 10.22.13 CHECKED G. SPRAGUE APPROVED L. COSTELLO APPROVED R. MCNIESH 1.10.98 6.3.98 6.3.98 6.3.98 TITLE MECHANICAL MASTER WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 COL. E -C/6-7 PLANT 2 SHEET M454 JOB NO. 972197-00 COMP NO. TWO NO. 2-81-M454 Page 22 of 27 v LADDER ACCESS TO MEZZ TRANSFORMER Ala v SEE DETAIL M1M456 M501 ELECTRICAL PANEL c /22'j X P HEATING COILS COOLING COILS, ACCESS I I I I II FILTER 1 1/2" 2 SA 66/18 MAINTENANCE AREA n EA�� 60/30 SEE DETAIL 4 > M1M456M501 EXTERIOR WALL 2"HWR—B 2"HWS— 3"CHWS-4 3"CHWR—i 36/60 30/60 30/60 TRANS 0 42/2 36/60 36/60 TRANS TO 60/36 42/24 MEZZ ACCESS HATCI- 60/36 SA OSA 36/24 M114456M502 42/24 ��� ENLARGED MEZZ PLAN SCALE: 1/4" = i'-0" 1M62,1M1 456 A (T) OSA REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION LEGEND GE►ERAL NOTES I� PROVIDE 1" DUCT LINER. SEE SPECIFICATIONS FOR TYPE. PROVIDE 1" THICK DUCT LINER FOR FIRST 20' DOWNSTREAM OF AHU-5. ® PROVIDE EXTENDED GREASE FITTINGS FROM BEARINGS TO INTERNAL PANEL. 15 > CROSS BRACING IS "SWALLOWED" WITH DUCTWORK AT LOUVER. REFERENCE DRAWINGS 1. FOR AHU DETAILS, SEE SHEET 2-81-M501. 2. FOR CONTINUATION OF DUCTWORK, SEE SHEET 2-81-1M12. 90% SUBMITTAL ISSUED FOR PERMIT CONSTRUCTION NOTES REFER TO ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. RECEIVED CITY OF TUKWILA NOV ' 1 '2 2013 PERMIT CENTER Wood Harbinger 7oO9 u21:11/We NE. Sapp Leo Beano WA 98.34 RY,RLE000 woodharDInge.com SYM REVISEN RECORD DRAWING 4972197-00 A CDC RELOCATION - WIRE SHOP RELOCATION 419760 BY HCI/SHS WH APPROVED DATE SYM REVISION BY APPROVED DATE 11.12.99 11BL 10.22.13 g)LATIZEAriVG® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BT DEPT. DATE DRAWN HGI AN HGI/SDF LAUNtLN HGI/GIF CHECKED G. SPRAGUE DATE 2.4.98 3.30.98 SUBTITLE MEZZANINE DUCTWORK CURRENT REVISION 419760 SYMBOL A DATE 10.22.13 2.4.98 6.3.98 APPROVED L. COSTELLO 6.3.98 NC ED N. R. NCNIESH 6.3.98 TTTLE WIRE SHOP RELOCATION TO 2-81 MECHANICAL MASTER BUILDING 2-81 COL. E -C/6-7 PLANT 2 M1M456 JOB NO. 972197-00 COMP NO. DWG NO. 2 -B1 -M1 M451Page 23 of 27 SIA A CLEARANCE: 1/8" PER LINEAR FOOT BOTH DIRCTIONS RETAINING ANGLES: MINIMUM • 1 1/2" X 1 1/2" X 0.054(16 GA.) 7 SECURE RETAINING ANGLES TO SLEEVE ONLY, ON 8" CENTERS WITH: 1. 1/2" LONG WELDS OR 2. 1/4" BOLTS AND NUTS, OR 3. NO. 10 STEEL SCREWS, OR 4. MINIMUM 3/16" STEEL RIVETS. I-- • MIN! 1-1 EACH SIDE STEEL SLEEVE: PER S.M.A.C.N.A. FIRE DAMPER: BLADE TYPE 1 SECURE DAMPER TO SLEEVE ON 8" CENTERS WITH: 1. 1/2" LONG WELDS OR 2. 1/4" BOLTS AND NUTS IN HOLES PROVIDED, OR 3. NO. 10 STEEL SCREWS, OR 4. MINIMUM 3/16" STEEL RIVETS. SECURE DUCT TO SLEEVE WITH A CONNECTION PER S.M.A.C.N.A. (TYPICAL) FIRE/SMOKE DAMPER SCALE NONE 11) M506 CONTROL PANEL MAINTENANCE CLEARANCE L J CEILING VIEW SCALE: NONE SEE ARCH FOR BASE FLASHING AND ROOF CURB REVB011 M506 TYPICAL INTAKE/EXHAUST PENTHOUSE NOTICE: "APPROVED" INSTALLATION INSTRUCTIONS GOVERN. SCALE: NONE RECORD DRAWING 4972197-00 CDC RELOCATION - WIRE SHOP RELOCATION J+19760 BY HGI/SHS WH AMMO DATE STU M506 REVISOR BY APPROVED 13> /14\I - M506 FAN TERMINAL BOX DETAIL PRIMARY SUPPLY AIR 24' CLEARANCE INDUCED AIR SUPPLY J OT WATER SUPPLY/RETURN CONTROL PANEL 24' I � % HOT WATER SUPPLY/RETURN J SCALE: NONE DUCT CLAMP OR DRAWBAND AT COLLAR DATE 11.12.99 MBL 10.22.13 DIFFUSER I 90 DEGREE RECTANGULAR TAKE -OFF WITH 45 DEGREE TAPER VOLUME DAMPER UN -LINED AIR DUCT SAME SIZE AS GRILLE INLET LEGEND GENERAL NOTES I 1 > DUCT TAP WITH VOLUME DAMPER, FLEXIBLE DUCT, AND INSULATED SUPPLY DIFFUSER PLENUM BOX WITH SIDE TAP. 2 > LOCATIONS OF HEATI MI> FLEX CONNECTION. DUCT MOUNTED SUPPLY GRILLE DETAIL DUCT HANGER 2 -WAY MODULATING CONTROL VALVE UNION (TYP) AUTOMATIC FLOW CONTROL VALVE- PRESSURE/TEMPERATURE TEST PORT (TYP) MANUAL AIR VENT FLEXIBLE CONNECTION (TYP HOSE END DRAIN VALVE CAPPED SIZE PER PIPING DIAGRAM ROUND SUSPENDED DIFFUSE SCALE: NONE VD n81111111111. FLEX DUCT SECTION B SUPPLY AIR DUCT BLANK PANEL INSULATED PLENUM BOX W/ SIDE CONNECTION SUPPLY DIFFUSER SCALE: NONE 2M10, 2M11, 2M12, 2M13 M506 e)LAFAREAVG. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE -DRAWN C. DEL.APP CHECIRD ANAPIER DATE 4.14.98 5.15.98 90% SUBMITTAL ISSUED FOR PERMIT SUBTITLE HVAC DETAILS REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION REFERENCE DRAWINGS CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA NOV 1 2 2013 PERMIT CENTER 1U) Wood Harbinger CURRENT REVISION 419760 SYMBOL A DATE 7m9 Muth Aye NE. Suite Too 8NIme WA 95004 4a5Aa&6000 wo001BN11n(esmm 10.22.13 N4WLLR G. FRANEN CHECKED G. SPRAGUE 4.14.98 6.3.98 �LPRovoo COSTELLO 6.3.98 APPROVED R. MCNIESH 6.3.98 BRE WIRE SHOP RELOCATION TO 2-81 MECHANICAL MASTER BUILDING 2-81 PLANT 2 EET M506 JOB N0. 972197-00 COMP N0. DWG NO. 2-81-M506 Page 24 of 27 PIE iilli mow 6"11 I-- • MIN! 1-1 EACH SIDE STEEL SLEEVE: PER S.M.A.C.N.A. FIRE DAMPER: BLADE TYPE 1 SECURE DAMPER TO SLEEVE ON 8" CENTERS WITH: 1. 1/2" LONG WELDS OR 2. 1/4" BOLTS AND NUTS IN HOLES PROVIDED, OR 3. NO. 10 STEEL SCREWS, OR 4. MINIMUM 3/16" STEEL RIVETS. SECURE DUCT TO SLEEVE WITH A CONNECTION PER S.M.A.C.N.A. (TYPICAL) FIRE/SMOKE DAMPER SCALE NONE 11) M506 CONTROL PANEL MAINTENANCE CLEARANCE L J CEILING VIEW SCALE: NONE SEE ARCH FOR BASE FLASHING AND ROOF CURB REVB011 M506 TYPICAL INTAKE/EXHAUST PENTHOUSE NOTICE: "APPROVED" INSTALLATION INSTRUCTIONS GOVERN. SCALE: NONE RECORD DRAWING 4972197-00 CDC RELOCATION - WIRE SHOP RELOCATION J+19760 BY HGI/SHS WH AMMO DATE STU M506 REVISOR BY APPROVED 13> /14\I - M506 FAN TERMINAL BOX DETAIL PRIMARY SUPPLY AIR 24' CLEARANCE INDUCED AIR SUPPLY J OT WATER SUPPLY/RETURN CONTROL PANEL 24' I � % HOT WATER SUPPLY/RETURN J SCALE: NONE DUCT CLAMP OR DRAWBAND AT COLLAR DATE 11.12.99 MBL 10.22.13 DIFFUSER I 90 DEGREE RECTANGULAR TAKE -OFF WITH 45 DEGREE TAPER VOLUME DAMPER UN -LINED AIR DUCT SAME SIZE AS GRILLE INLET LEGEND GENERAL NOTES I 1 > DUCT TAP WITH VOLUME DAMPER, FLEXIBLE DUCT, AND INSULATED SUPPLY DIFFUSER PLENUM BOX WITH SIDE TAP. 2 > LOCATIONS OF HEATI MI> FLEX CONNECTION. DUCT MOUNTED SUPPLY GRILLE DETAIL DUCT HANGER 2 -WAY MODULATING CONTROL VALVE UNION (TYP) AUTOMATIC FLOW CONTROL VALVE- PRESSURE/TEMPERATURE TEST PORT (TYP) MANUAL AIR VENT FLEXIBLE CONNECTION (TYP HOSE END DRAIN VALVE CAPPED SIZE PER PIPING DIAGRAM ROUND SUSPENDED DIFFUSE SCALE: NONE VD n81111111111. FLEX DUCT SECTION B SUPPLY AIR DUCT BLANK PANEL INSULATED PLENUM BOX W/ SIDE CONNECTION SUPPLY DIFFUSER SCALE: NONE 2M10, 2M11, 2M12, 2M13 M506 e)LAFAREAVG. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE -DRAWN C. DEL.APP CHECIRD ANAPIER DATE 4.14.98 5.15.98 90% SUBMITTAL ISSUED FOR PERMIT SUBTITLE HVAC DETAILS REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION REFERENCE DRAWINGS CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA NOV 1 2 2013 PERMIT CENTER 1U) Wood Harbinger CURRENT REVISION 419760 SYMBOL A DATE 7m9 Muth Aye NE. Suite Too 8NIme WA 95004 4a5Aa&6000 wo001BN11n(esmm 10.22.13 N4WLLR G. FRANEN CHECKED G. SPRAGUE 4.14.98 6.3.98 �LPRovoo COSTELLO 6.3.98 APPROVED R. MCNIESH 6.3.98 BRE WIRE SHOP RELOCATION TO 2-81 MECHANICAL MASTER BUILDING 2-81 PLANT 2 EET M506 JOB N0. 972197-00 COMP N0. DWG NO. 2-81-M506 Page 24 of 27 1/2" STREET ELBOW TYP 1/2'X3/8" HEX BUSHING BALL VALVE WATTS #B-6080 PIPE SLEEVE HAND OPERATED TREADLE n 1/4" QUICK DISCONNECT SOCKET, PARKER B22E 1/4' QUICK DISCONNECT BODY x 3/8"MPT FLOOR I 100 PSI AIR FLOOR MOUNTED DUPLEX AIR OUTLET n SCALE: NONE M513 DRAIN IN WALL FLOOR 1/2"CW TO BE ROUTED IN WALL 5 EYE WASH FOUNTAIN DETAIL (P-7) SCALE: NONE FLOOR OR ROOF DRAIN SYM A RUN TO FLOOR OR ROOF DRAIN SLOPE SHALL BE MIN. 1/4" PER FT .OF RUN 1 LOCATE 4.-0" ABOVE FINISHED FLOOR —•� PARKER EZ-251-6FP 3/8" FPT x 1/4" SOCKET QUICK DISCONNECT (TYP) WALL OR STRUCTURE !!! (REF) WALL BOARD ANCHOR SCREW AND WASHER MOLLY BOLT OR EXPANDING TYPE ANCHOR (2 PLACES) B -UNE B-22 CHANNEL OR EQUAL 100 PSI AIR WALL MOUNTED DUPLEX AIR OUTLET CHWS — REDUCED PRESSURE BACKFLOW PREVENTER PD f r TO FLOOR DRAIN HYDRAULIC UNIT (U -D SHAKER SIMILAR) TO FLOOR DRAIN CHWR -� 1" HYDRAULIC PIPE BY OTHERS REDUCED PRESSURE BACKFLOW HYDRAULIC TRENCH PREVENTOR TO HYDAULIC UNIT SCALE: NONE PIPING 1M110,1M113,1,60,1M63IM513 SCALE. NONE REVIEWED FO CODE COMPLIANCE APPROVED NOV 27 2013 rTh M513 1/2" PIPE NIPPLE (TYP) 1/2" ALL PURPOSE HOSE 200 PSI BOSTON PERFORMER H11508 1/2" PIPE NIPPLE (TYP) 1/2" ALL PURPOSE HOSE 200 PSI BOSTON PERFORMER H11508 City of Tukwila BUILDING DIVISION PLUG AIR GAP: 2 TIMES PIPE 0 (MAX. = 2") REVISOR EQUAL TO 1/2 STATIC PRESSURE RATING OF UNIT PLUS 1" CONDENSATE DRAIN DETAIL SCALE: NONE MM13 RECORD DRAWING 4972197-00 CDC RELOCATION - WIRE SHOP RELOCATION 419760 BY HCI/SHS WH APPROVED DATE 11.12.99 SIM 1/2" ALL PURPOSE HOSE 200 PSI BOSTON PERFORMER H11508 1/2" ALL PURPOSE HOSE 200 PSI BOSTON PERFORMER H11508 AHU + FCU DRAIN PAN 1/2" BLK MI ELBOW ON A DRAW THRU UNIT: EQUAL TO STATIC PRESSURE OF UNIT; ON A BLOW THRU UNIT: EQUAL TO 0" PIPE SIZE SAME AS UNIT DRAIN CONNECTION REVISION RECEIVED ITY OF TUKW PARKER EZ-251-6FP 3/8" FPT, x 1/4" SOCKET QUICK DISCONNECT (TYP) 1101 1101 PARKER EZ-251-6FP 3/8" FPT x 1/4" SOCKET QUICK DISCONNECT (TYP) BY APPROVED DATE CEL 10.22.13 cel_4,0E/AVG• ACCEPTABILITY THIS DESIGN MND/DR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN G. KREWIN MOM S. FRANKLIN 3.30.98 DATE 3.26.98 /ENGME[N E. YOOSFIAN 3.26.98 QUADRUPLEX FLEXIBLE AIR DROP OUTLET SUBTITLE PLUMBING DETAILS NOV 1:2 201 ERMIT CENT 90% SUBMITTAL ISSUED FOR PERMIT CURRENT REVISION 972197-00 SYMBOL A DATE 10.22.13 CHECKED G. SPRAGUE 6.3.98 APPROVED - L. COSTELLO 6.3.98 APPROVED R. MCNIESH 6.3.98 TOLE MECHANICAL MASTER WIRE SHOP RELOCATION TO 2-81 BUILDING 2-81 MBL SHEET M513 JOB NO. 972197-00 COMP NO. DWG NO. 2-81-M513 Page 25 of 27 ILA ER r. -T 1 11B5 2'V,UP hr 12'-10" 9,-7" CONT'D ON DWG UGM112 4"FCO 7 CONT'D ON DWG UGM112 2"FCO 3 � 4 % i U 1/2"HW-;:-' "CW 4'-2" 5'+0" LEGEND _R_ REFRIGERANT LINE BY KITCHEN EQUIPMENT CONTRACTOR 1/2' CA +72" ROUGH -IN ELEV. (ABOVE FLOOR) PIPE SIZE AND COMMODITY FD FLOOR DRAIN FS FLOOR SINK GENERAL NOTES 1. FOR CONTINUATION OF PIPING, SEE SHEET UGM112. 2 > PROVIDE CATCH BASIN AT DOCK AREA AT GREASE CONTAINER. SEE NOTE 2, DWG C305. 3 > PROVIDE 2" PVC SLEEVE FOR ENTIRE LENGTH OF 1 2" UNDERGROUND TUBING 4 > PIPING ABANDONED IN PLACE AND CAPPED. CAPPED 2"V,UP (TYP) 2'SAN +12' 4"SAN UP TO FCO 13'-9" 10'-4 1/2" 14'-7" FOR CODE COMPLIANCE APPROVED OYU A B 0 L REV90N RECORD DRAWING J1972197-00 LAPTOP HOTELINC IOf13884-50 CDC RELOCATION - WIRE SHOP RELOCATION J119760 BY HGI/SHS WDB WH (W1,' ARE tOvED DATE 0 NOV 2 7 2013 City of Tukwila BUILDING DIVISIO SYM REVISION ay DATE NEIL 11.12.99 1.12.12 10.22.13 KITCHEN - UNDERGROUND SCALE: 1/4" = 1'-0" UGM112 UGM455 celeotrsArtc® ACCEPTABILITY 196 DESIGN AND/OR SPECIE CATION 6 APPROVED APPROVED OV DEPT. DATE IA. S. FRANKLIN 'LNI,INLLR G. FRANEK DATE 12.15.97 3E7 _ 1L 90% SUBMITTAL ISSUED FOR PERMIT 3.30.98 SUBTITLE ENLARGED PLUMBING PLAN REFERENCE DRAWINGS 1. SEE ARCHITECT DWG 2-81-A460 FOR EQUIPMENT ITEM NUMBERS. 2. SEE ARCHITECT DWG. 2-81-A360 AND A361 FOR EQUIPMENT SCHEDULE. CONSTRUCTION NOTES POINT OF CONNECTION TO EXISTING UNDERSLAB SANITARY LINE. RECEIVED CITY OF TUKWILA NOV 1 2 2013 PERMIT CENTER I l'1\)til Wood Harbinger CURRENT REASON J(J19760 SYMBOL B Wog vrth Awe NE. Sulo too Belk". WA 91024 wOOdlarbIngel.cOm DATE 10.22.13 CHECKED G. SPRAGUE 12.15.98 6.3.98 APPROVED L COSTELLO APPROVED R. UCNIESH 6.3.98 6.3.98 TTTLE WIRE SHOP RELOCATION TO 2-81 MECHANICAL MASTER BUILDING 2-81 COL. E -C/6-7 PLANT 2 SNEEET UGM455 JOB NO. 972197-00 COMP NO. ONG NO. 2-81-UGM455Page 26 of 27 PIPE FfTTING SYMBOLS � VTR ®RD FD ®FS ® FFD FUD PIPING SYMBOLS REDUCER, CONCENTRIC REDUCER, ECCENTRIC UNION, SCREWED ELBOW, TURNING DOWN OR AWAY ELBOW, TURNING UP OR TOWARD TEE, OUTLET DOWN OR AWAY TEE, OUTLET UP OR TOWARD CAP, SCREWED OR SOLDER JOINT BLIND FLANGE PLUG CAP, WELDED OR GROOVED ELBOW, 90' TEE CROSS FITTING SYMBOLS LATERAL WCO WASTE PIPING QUARTER BEND SANITARY WYE AND 1/8 BEND ELBOW, 45' CLEAN OUT, FLOOR CLEAN OUT, WALL VENT THRU ROOF ROOF DRAIN FLOOR DRAIN FLOOR SINK FUNNEL FLOOR DRAIN FUNNEL DRAIN VALVE SYMBOLS --Da— —104- -00 —0O —�$H- -I.I- -DDo-- - -� —g_ GATE VALVE, OUTSIDE SCREW AND YOKE GATE VALVE, (NORMALLY OPEN) GATE VALVE, (NORMALLY CLOSED) GATE VALVE WITH HOSE CONNECTION BALL VALVE, (NORMALLY OPEN) BALL VALVE, (NORMALLY CLOSED) BUTTERFLY VALVE GLOBE VALVE, (NORMALLY OPEN) GLOBE VALVE, (NORMALLY CLOSED) ANGLE GLOBE VALVE, PLAN ANGLE GLOBE VALVE, ELEVATION PLUG VALVE/STOP COCK CHECK VALVE 3 WAY VALVE BALANCING VALVE WITHOUT METERING PORTS BALANCING VALVE WITH METERING PORTS AUTOMATIC FLOW CONTROL VALVE NUMBER INDICATES GPM FLOAT VALVE NEEDLE VALVE HOSE BIB PRESSURE REDUCING/REGULATING VAVE WITH EXTERNAL PRESSURE TAP PRESSURE REDUCING/REGULATING VALVE SELF CONTAINED PRESSURE RELIEF/SAFETY VALVE VALVE SYMBOLS CONT. MOTOR OPERATED VALVE SOLENOID OPERATED VALVE 3 WAY CONTROL VALVE CONTROL VALVE QUICK OPENING QUICK CLOSING, FUSIBLE LINK VALVE IN RISER MISCELLANEOUS PIPING SYMBOLS EQUIPMENT MARK NUMBER -7? POINT OF CONNECTION AIR VENT, AUTOMATIC (WITH DRAIN) -,MAV AIR VENT, MANUAL (WITH DRAIN) BACKFLOW PREVENTER COOLING COIL HEATING COIL EXPANSION JOINT FLOWMETER, ORIFICE FLOWMETER, VENTURI PRESSURE GAGE WITH VALVE STRAINER, WYE WITH BLOW OFF STRAINER, WYE STRAINER, BASKET STRAINER, DUPLEX TEST PLUG (PETE'S PLUG) TRAP SEAL PRIMER VALVE —ID— STEAM TRAP —® VALVE BOX PIPE GUIDE PIPE SUPPORT HANGER SPRING HANGER --X— PIPE ANCHOR ® NITROGEN GAS OUTLET, HARD PIPE ® NITROGEN GAS DROP, HOSE B VACUUM OUTLET, HARD PIPE • VACUUM DROP. HOSE IW VACUUM CLEANING OUTLET Q SIMPLEX AIR DROP, HOSE DUPLEX AIR DROP, HOSE e SIMPLEX AIR OUTLET, HARD PIPE • DUPLEX AIR OUTLET, HARD PIPE AIR CONDITIONING. REFRIGERATION AND COOLING SYMBOLS — CHWS - - CHWR - - CLWS- -CLWR- - CTFS - - CTFR — - CTWR — — HPWS — HPWR - - CLD - -RS- -RL- - RHG — PIPING IDENTIFICATION SYMBOLS HVAC SYMBOLS CONT. CHILLED WATER SUPPLY CHILLED WATER RETURN COOLING WATER SUPPLY COOLING WATER RETURN COOLING TOWER FILTER SUPPLY COOLING TOWER FILTER RETURN FROM COOLING TOWER) DOLING TOWER WATER RETURN (TO COOLING TOWER) HEAT PUMP WATER SUPPLY HEAT PUMP WATER RETURN CLEAR WATER DRAIN (CONDENSATION) REFRIGERANT SUCTION (GAS) REFRIGERANT LIQUID REFRIGERANT HOT GAS HEATING SYMBOLS — HWS — HEATING WATER SUPPLY — HWR - - STM- - HPS — — MPS - - LPS HEATING WATER RETURN STEAM SUPPLY HIGH PRESSURE STEAM SUPPLY (125 - 250 PSIG) MEDIUM PRESSURE STEAM SUPPLY (15 - 125 PSIG) LOW PRESSURE STEAM SUPPLY (0 - 15 PSIG) — HPR — CONDENSATE RETURN (PRESSURE), STEAM — C— CONDENSATE RETURN (GRAVITY), STEAM — PC — CONDENSATE (PUMPED), STEAM — CD — CONDENSATE DRAIN -, — HPC — CONDENSATE, STEAM (HIGH PRESSURE) 1 — MPC — CONDENSATE, STEAM (MEDIUM PRESSURE) — LPC — CONDENSATE, STEAM (LOW PRESSURE) I — BBD — BOILER BLOW DOWN — BFW — BOILER FEED WATER FUEL OIL SYMBOLS — FO — FUEL OIL — FOD — FUEL OIL DISCHARGE — FOG — FUEL OIL GAUGE — FOS — FUEL OIL SUPPLY — FOR — FUEL OIL RETURN — FOV — FUEL OIL VENT — FOF — FUEL OIL FILL LINE PLUMBING AND MISCELLANEOUS SYMBOLS — A— COMPRESSED AIR (100 PSIG NOMINAL) — IA — INSTRUMENT AIR — CF — CHEMICAL FEED — F— FIRE LINE (AHEAD OF ALARM VALVE) —S— SPRINKLER LINE (DOWNSTREAM OF ALARM VALVE) — G— NATURAL GAS — LPG — LIQUID PETROLEUM GAS — LN2 — LIQUID NITROGEN — GN2 — GASEOUS NITROGEN — VAC — VACUUM — CLV — VACUUM CLEANING PLUMBING AND MISCELLANEOUS SYMBOLS CONT. - VPD - -CW- - HW- - HNC - - DI- - DW- - PW- - AW- - CRV - - CRW- - ID- - fW- - SAN - - STS - -RWL— VACUUM PUMP DISCHARGE COLD WATER, DOMESTIC HOT WATER, DOMESTIC HOT WATER, CIRCULATING DOMESTIC DEIONIZED WATER DISTILLED WATER PROCESS WATER ACID WASTE CORROSION RESISTANT VENT CORROSION RESISTANT WASTE INDIRECT DRAIN INDUSTRIAL WASTE SANITARY WASTE STORM DRAIN, RAIN WATER LEADER —V— VENT HVAC SYMBOLS BASIC DUCTWORK SYMBOLS RECTANGULAR DUCT (FIRST NUMBER INDICATES SIZE FOR SIDE SHOWN) 240 4 iL AD Ea ROUND DUCT (NUMBER INDICATES DIAMETER) SUPPLY AIR DUCT, RECTANGULAR ELBOW TURNING TOWARD SUPPLY AIR DUCT RECTANGULAR ELBOW TURNING AWAY EXHAUST AIR OR RETURN AIR DUCT RECTANGULAR ELBOW TURNING TOWARD EXHAUST AIR OR RETURN AIR DUCT RECTANGULAR ELBOW TURNING AWAY RECTANGULAR DUCT, SQUARE ELBOW, SHOWN WITH TURNING VANES ROUND DUCT, ELBOW TURNING TOWARD ROUND DUCT ELBOW TURN(NG AWAY FLEXIBLE DUCT FLEXIBLE DUCT CONNECTION DUCTWORK AIRFLOW DIRECTION ACCESS DOOR (AD) ACCESS PANEL (API GRILLES. LOUVERS. DIFFUSERS, AND OPENING SYMBOLS XXX CFM �' CFM ,, RR RG ER EG SD SG SR TG SD 12/6 100 CFM 12/6 ~ h OO CFM II_�RG 12/6 Ir100 CFM SD 12/12 ® 400 CFM 0 SD 12/12 400 CFM SD 12 O 400 CFM RG 24X24 100 CFM SUPPLY OR OUTSIDE AIR FLOW DIRECTION RETURN TRANSFER OR EXHAUST AIR FLOW DIRECTION RETURN REGISTER RETURN GRILLE EXHAUST REGISTER EXHAUST GRILL SUPPLY DIFFUSER SUPPLY GRILLE SUPPLY REGISTER TRANSFER GRILLE SIDEWALL SUPPLY AIR DIFFUSER, GRILLE OR REGISTER SCREENED OPENING SIDEWALL RETURN/EXHAUST AIR GRILLE OR REGISTER SUPPLY OUTLET DIFFUSER, GRILLE OR REGISTER SUPPLY OUTLET DIFFUSER, GRILLE OR REGISTER SUPPLY OUTLET ROUND DIFFUSER RETURN/EXHAUST REGISTER OR GRILLE GRILLES. LOUVERS DIFFUSERS. AND OPENING SYMBOLS CONT. .1L Di 4. FAN, AXIAL FLOW LINEAR DIFFUSER 100 CFM r7ICG 24/24 100 CFM RETURN/RELIEF GRILLE, CEILING TYPE NON -DUCTED DUCT MOUNTED EQUIPMENT SYMBOLS p CENTRIFIGAL FAN Q CENTRIFIGAL FAN. INLET GUIDE VANES C -- —,A UNIT HEATER TERMINAL UNIT INSTRUMENTATION AND CONTROL SYMBOLS O H ZINIM eP DUCT TYPE HEAT DETECTOR DUCT TYPE SMOKE DETECTOR DUCT TYPE TEMPERATURE SENSOR CO TEMPERATURE TRANSMITTER OT THERMOSTAT OH HUMIDISTAT ovc4. DAMPER SYMBOLS VOLUME DAMPER OPPOSED BLADE DAMPER PARALLEL BLADE DAMPER BACK DRAFT DAMPER (ALLOWS FLOW IN DIRECTION OF ARROW) FIRE DAMPER (1 HOUR) FIRE DAMPER (2 HOUR) SMOKE DAMPER FIRE/SMOKE DAMPER REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION FOR REFERENCE ONLY FACILITY DESIGN BY WH DATE 09.05. I3 RECEIVED CITY OF TUKWILA NOV 1 2 2013 PERMIT CENTER srM RECORD DRAWING 4972197 -OD BY HGI/SHS APPROVED DATE SYM REVISION BY APPROVED DATE 11.12.99 gLiroirAtArc• ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED ,DRAWN S. FRANKLIN DATE 2.18.98 A. NAPIER 3.30.98 SUBTITLE LEGEND CURRENT REVISION SYMBOL DATE 11.12.99 APPROVED BY DEPT. DATE ENGINEER G. FRANEK 2.18.98 CHECKED G. SPRAGUE 6.3.98 APPROVED L COSTELLO 6.3.98 APPROVED R. YCNIESH 6.3.98 TITLE MECHANICAL MASTER BUILDING 2-81 PLANT 2 SHED MO JOB NO. 972197-00 COMP NO. OMC NO. 2 -81 -MO Page 27 o127 i PERMIT COORD COPY I'_ PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-0207 DATE: 11/12/13 PROJECT NAME: BOEING #2-81 SITE ADDRESS: 8123 EAST MARGINAL WY S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter #_ Revision # after Permit Issued DEPARTMENTS: tVj Building Division Public Works Pc\4(/ ' t ' Fire PreventionI� Structural Planning Division Permit Coordinator U DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11/14/13 Complete Incomplete Not Applicable 111 Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 0 LETTER OF COMPLETENESS MAILED: Fire ❑ Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route ,0 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 12/12/13 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeopleter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name DESIGN AIR LTD UBI No. 600314241 Phone 2538542770 Status Active Address 8657 South 190Th St License No. DESIGL*212DG Suite/Apt. License Type Construction Contractor City Kent Effective Date 3/7/1979 State WA Expiration Date 3/7/2014 Zip 98031 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status MRCCOL'981JB M C CONSTRUCTION CONSTRUCTION LLC Construction Contractor General Unused 4/2/2002 4/29/2012 Expired Business Owner Information Name Role Effective Date Expiration Date HAGEN, RONALD A President 01/01/1980 Amount PORTO, MARK M Secretary 03/08/2010 g14025755083 MATZ, RICHARD K Vice President 03/08/2010 Bond Information Page 1 of 2 Bond 8 Bond Company Name TRAVELERS CAS a SURETY CO Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 103742548 03/07/2002 Until Cancelled $12,000.00 02/28/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 33 Continental Cas o g14025755083 10/01/2013 10/01/2014 52,000,000.0009/23/2013 32 Continental Cas o GL2095787039 10/01/2012 10/01/2013 $2,000,000.00 10/01/2012 31 Continental Cas o GL2095786635 10/01/2011 10/01/2012 $2,000,000.00 09/30/2011 30 CONTINENTAL CAS CO GL2095785243 10/01/2010 10/01/2011 $2,000,000.0009/27/2010 29 CONTINENTAL CAS CO GL2095786232 10/01/2009 10/01/2010 $2,000,000.00 09/25/2009 28 CONTINENTAL CAS CO GL2095785744 10/01/2008 10/01/2009 $2,000,000.00 09/23/2008 27 CONTINENTAL CAS CO GL2095785744 10/01/2008 10/01/2009 $2,000,000.00 09/23/2008 26 CONTINENTAL CAS CO GL2095783234 10/01/2007 10/01/2008 $2,000,000.00 09/24/2007 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period httns://fortress.wa.gov/lni/bbin/Print.asnx 12/04/2013