HomeMy WebLinkAboutPermit M13-0210 - ABU-BAKR ISLAMIC CENTER - REPLACE ROOF TOP UNITABU-BAKR ISLAMIC CENTER
14101 TUKWILA
INTERNATIONAL BLVD
EXPIRED 06/14/14
M13-0210
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-438-9350
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT`
Parcel No: 1610000125 Permit Number: M13-0210
Address: 14101 TUKWILA INTERNATIONAL Issue Date: 12/16/2013
BLVD 1 Permit Expires On: 6/14/2014
Project Name: ABU-BAKR ISLAMIC CENTER
Owner:
Name: ABU-BAKR ISLAMIC CTR OF WA
Address: PO BOX 68069 , TUKWILA, WA, 98169
Contact Person:
Name: ABDIRISAK AHMED Phone: (206) 251-6976
Address: 14101 TUKWILA INTERNATIONAL B ,
TUKWILA, WA, 98168
Contractor:
Name: ALL HITECH HEATING & A/C LLC
Address: 14724 NE 4 PL, BELLEVUE, WA, 98007
License No: ALLHIHH873MW
Lender:
Name:
Address:
Phone: (425) 747-0677
Expiration Date:
DESCRIPTION OF WORK:
REMOVE & REPLACE OLD ROOFTOP GAS PACKS LIKE FOR LIKE
Valuation of Work: $5,000.00
Type of Work: REPLACEMENT
Fuel type: GAS
Fees Collected: $249.00
Electrical Service Provided by: SEATTLE CITY LIGHT
Water District: 125
Sewer Distric: VALLEY VIEW SEWER SERVICE
Current Codes adopted by the City of Tukwila:
Internations Building Code Edition:
International Residential Code Edition:
International Mechanical Code Edition:
Uniform Plumbing Code Edition:
2012 International Fuel Gas Code:
2012 WA Cities Electrical Code:
2012 WA State Energy Code:
2012
2012
2012
2012
Permit Center Authorized Signature;
Date: t ` 1( Q113
I hearby certify that I have read and examined this permit and know the same to be true and correct. All
provisions of law and ordinances governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other
state or local laws g ating • onstruction or the performance of work. I am authorized to sign and obtain this
development p; an •_�; - the conditions attached to this permit.
Signature:
Print Name:
4-1041-1 se.k..J(.
YY)
Date: 1 ( r
1
This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or
if the work is suspended or abandoned for a period of 180 days from the last inspection.
PERMIT CONDITIONS:
1: Work shall be installed in accordance with the approved construction documents, and any changes made
during construction that are not in accordance with the approved construction documents shall be
resubmitted for approval.
2: All permits, inspection record card and approved construction documents shall be kept at the site of work
and shall be open to inspection by the Building Inspector until final inspection approval is granted.
3: Readily accessible access to roof mounted equipment is required.
4: All construction shall be done in conformance with the Washington State Building Code and the
Washington State Energy Code.
5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap
the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks,
wells, and other excavations. Final inspection approval will be determined by the building inspector
based on satisfactory completion of this requirement.
6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the
City of Tukwila Building Department (206-431-3670).
7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila
Permit Center.
8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an
approval of, any violation of any of the provisions of the building code or of any other ordinances of the
City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or
other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction
documents and other data shall not prevent the Building Official from requiring the correction of errors in
the construction documents and other data.
9: ***MECHANICAL PERMIT CONDITIONS***
10: All mechanical work shall be inspected and approved under a separate permit issued by the City of
Tukwila Permit Center (206/431-3670).
11: Manufacturers installation instructions shall be available on the job site at the time of inspection.
PERMIT INSPECTIONS REQUIRED
Permit Inspection Line: (206) 438-9350
0703 MECH EQUIP EFF
1800 MECHANICAL FINAL
0705 REFRIGERATION EQUIP
0701 ROUGH -IN MECHANICAL
CITY OF TUKTylig
Community DevelopmeW epartment
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical P
Project No.
Date Application Accepted:
Date Application Expires \ (`
or office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
Site Address: 10k �111\KM' 14 JW'1 \ ,,W
Tenant Name: Pt\ C
King Co Assessor's Tax No.: vll')...\ -0) sS
Suite Number: Floor:
,PROPERTY OWNER -
Name: (\
Address: 19\0) r"\--V\\kW(LA 1111 v
City \V\\<_�,.111`I� Statekl• Zip C�lD\6D
CONTACT,PERSON =person receiving all, project
communication `"
Name: kok,\,,s4,.., " I A v.-
Address: \L\t.7�� NQ u - p
Address: (/ 61 /U/i A ►t1 /� Zs
r
'
City: ) V.Ck)l 1w State: lidZip:9oj
G! '
Phone:2-06 2C1-7& /, Fax:
Email: a✓JV.(lja�'(f GClre °"t Imauk'-
t(fv"i
New Tenant: ❑ Yes ❑.. No
MECHANICAL CONTRACTOR INFORMATION
Company Name: 1T� , y \�‘_‘..,\ \s\Nz'� \13L^
Address: \L\t.7�� NQ u - p
City:,bjo State:W,�nTT'' Zip:q.zp�-7
Phone: n 4:4..._,..).7q. _$.63Fax:
Contr Reg No.: Exp Date:
Tukwila Business License No.:
Valuation of project (contractor's bid price): $ 0 r 0
Describe the scope of work in detail: 9.\\'_yvv g \ ���\f� 17 D\� �Q\ �� l�(kf‘S
L�\cam FOR L\ 1<`z
Use:
Fuel Type:
Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement
Electric ❑
Gas
Other:
H:\Apphcations\Forms-Applications On Lme\201 I Applications\Mechanical Permit Application Revised 8-9-I I.docx
Revised: August 2011
bh
ti
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit type
Qty'
Furnace <100k btu
7.
Furnace >100k btu
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
.Qty;
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
'Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
•
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY - LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OW
Signature:
Print Name:
ORI ED AGENT:
Mailing Address:
Atilkyv* "or\
(c/ dw w lA �a uL11,
H:1Appl'cations \Forms -Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-I I.docx
Revised: August 2011
bh
Day Telephone: .7C6 ' �i ((O? (/
City State Zip
Page 2 of 2
Cash Register Receipt
City of Tukwila
DESCRIPTIONS
ACCOUNT
QUANTITY I PAID
M13-0210 Address: 14101 TUKWILA INTERNATIONAL BLVD 1 Apn: 1610000125
MECHANICAL
$127.12
PERMIT FEE
PLAN CHECK FEE
TOTAL FEES PAID BY RECEIPT: R398
R000.322.100.00.00
R000.322.102.00.00
$101.70
$25.42
$127.12
Date Paid: Monday, December 16, 2013
Paid By: ABU-BAKR ISLAMIC CENTER
Pay Method: CREDIT CARD 140043
Printed: Monday, December 16, 2013 10:32 AM 1 of 1
CRWSYSTEMS
Cash Register Receipt
City of Tukwila
DESCRIPTIONS I ACCOUNT
PermitTRAK
I QUANTITY I
PAID
$121.88
M13-0210 Address: 14101 TUKWILA INTERNATIONAL BLVD 1
Apn: 1610000125
$121.88
MECHANICAL
$121.88
PERMIT FEE 000.322.100.00.00
$65.00
PERMIT ISSUANCE BASE FEE 000.322.100.00.00
$32.50
PLAN CHECK FEE 000.322.102.00.00
TOTAL FEES PAID BY RECEIPT: R82
$24.38
$121.88
Date Paid: Tuesday, November 12, 2013
Paid By: ABDIRISAK A AHMED ABU-BAKR ISL .
Pay Method: CREDIT CARD 398424
Printed: Tuesday, November 12, 2013 4:04 PM 1 of 1
RWSYSTEMS
SEPARATE PERMIT
REQUIRED FOR:
0 MAcnanical
Electrical
Plumbing
Gas Piping
City of Tukwila
BUILDING DIVISION
arcE
D�IDIKI
.--Au ovosD nun'
6 MAL 910-T11IA1
a•
N
NAf✓1w6H+ AIR SEM 50
sate EVEPORCIVE COMER
F.
io JI%le r ,T n OO54D m�g,J6tl01
PlFlmll DOLT SEIRo1
Sn•a YR to - ILO MARY
_..!I
FL:1IC Y - WELD 077.11
RCM MUT
Ovl®MGA,
r
e�-
O
0
0
0
0
RSD WOON O
Dnr,&L IDR W-2..0. 0l \ eu
00\
muni C'•
v0D R.
DP. ON *10015r TOP
RA
CUNT N CEY6
IRC6hM KAT
egata
6TG
MUTE MIM 50055510
1WORK 601469 MINA CULT
02lTOR 'I 16.ND
1 MCI SIM 6
MOE INSUUTICN TITOT FOR O00.
1461
FLOOR PLAN
s,..r 1/r -1r
mq9-co-lo
REVISIONS
No changes shall be made to the scope
of work without prior approval of
Tukwila Building Division.
WOTE: Revisions will require a new plan submittal
and may include additional plan review fees. j
UST. Y 6558
C13 51(2
ROLM
NTN -W
OO6LR
I EVOEWI D FOR
CODE CIS iPLIANCE
NOVAPPROVED
2 / 2013
. 1 J
City if RA wiOa
BUOLLDiI ' AAMON
RECEIVED
CITY OF TUKWILA
GIOV 1 "12013
PERMIT CENTER
all N IIRRIDR
y'1NDSiD
13-m.02A0
u-zSLbLS�ULi" U
pcx aool 1\1, (92—DZI,0
Plan reviewFlo 10 h
Approval of con
the violation of an
app ved FrafJ
asks=Wow.
.
not authorize
or ordinance. Receipt
ed:
Dft
DEHAAS
ENGINEERING
56210 MARK[ VAY DR. S.
1GR NO.N05. Y Sb1S0
DRAWING
mR:10
oR® PD
ISS 9 E D
Iu1,3/12/99
REVISIONS
5(0(0
TITLE
HVAC
FLOOR PLAN
21 CLUB
TUKWGLA. WA
IRD,E CI
Till
MEM
a1.CR TORR.
999
1OILI NC.
M-2
2 OF 2
ay Of INhvO
HEATING & AIR CONDITIONING
SUBMITTAL D%ATRLEc
Order #:
Project: All Hi -Tech
Project #:
Location:
For: Approval
Date: 10/28/2013
REVIEWED FOR
CODE COMPLIANCE
APPROVED
NOV 2 7 2013
City of Tukwila
BUILDING DIVISION
RECEIVED
CITY OF TUKWILA
NOV t =2 2013
PERMIT CENTER
Unitary Sales Tool v1.5.7.30
Information is sub)ect to change without notice. Check local codes. Printed 10282013
Date
10/28/2013
Project Name
All Hi -Tech
Project Number
Client / Purchaser
Submittal Summary Page
HEATING 8 AIR CONDITIONING
Qty Tag # Model # Description
1 ZS-04NO7AFAAA2 4 Ton, Single Packaged R -410A Air Conditioner, 13.0 SEER / 11.0
EER, Single Stage Cooling, 75 MBH Input Aluminized Steel, Single
Stage Gas Heat, 1 HP Direct Drive Blower, 1" Throwaway Filters,
208/230-1-60, Microchannel Condenser Coil, Galvanized Steel
Drain Pan
2EE04703724 Single Enthalpy Economizer (Downflow or Horizontal Unit) with
Hood Kit
Barometric Relief Damper with Hood Kit (Downflow Unit or Duct
Mounted)
1
1 RD0410
Equipment start-up and commissioning by a factory trained technician is recommended.
Contact your supplying distributor or sales representative for additional information & guidance.
Unitary Sales Tool v1.5.7.30
Information is subject to change without notice. Check local codes.
Printed 10/28/2013
Coleman
HEATING A AIR c0NGm0NING
3-6 Ton Package
Single Package R -410A Air Conditioner
Page: 3
Project Name: All Hi -Tech
Unit Model #: ZS-04NO7AFAAA2
Quantity: 1
System: ZS-04NO7AFAAA2
t,;ooung rerrormance
Total capacity 53 2 MBH
Sensible capacity 37.1 MBH
Refrigerant type R -410A
Seasonal Efficiency (at ARI) 13.00 SEER
Efficiency (at ARI) 11.00 EER
Ambient DB temp. 84.9 °F
Entering DB temp. 80.0 °F
Entering WB temp. 67.0 °F
Leaving DB temp. 58.5 °F
Leaving WB temp. 56.4 °F
Power input (w/o blower) 3.42 kW
Sound power 80 dB(A)
Gas Heating Performance
Entering DB temp. 60 °F
Heating output capacity (Max) 59 MBH
Supply air 1600 CFM
Heating input capacity (Max) 75 MBH
Leaving DB temp. 94.1 °F
Air temp. rise 34.1 °F
SSE 81.6 %
AFUE 80.9 %
Stages 1
Supply Air Blower Performance
Supply air 1600 CFM
Ext. static pressure 0.87 IWG
Unit static resistance 0.11 IWG
Blower speed 1097 RPM
Duct location Bottom
Motor rating 1.00 HP
Actual required BHP 0.75 HP
Power input 0.70 kW
Elevation 433 ft.
Drive type DIRECT
Speed tap 5
Electrical Data
Power supply 230-1-60
Unit min circuit ampacity 29.5 Amps
Unit max over -current protection 40 Amps
Dimensions & Weight
Hgt 33 in. Len 83 in. Wth 45 in.
Weight with factory installed options 596 lbs.
Clearances
Right 24 in. Front 32 in. Back 36 in.
Tnn 79 in nnHnm rl in I oft ZR in
Note: Please refer to the tech guide for listed maximum static pressures
.ALIS cEHFIFIEo.
4 Ton
• Coleman Units are Manufactured at an ISO 9001 Registered Facility and
Each Rooftop is Completely Computer -Run Tested Prior to Shipment.
Unit Features
• Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours
Salt Spray Test (ASTM B-117 Standards)
• Through -the -Curb and Through -The -Base Utility Connections
• Either Supply and/or Return can be Field Converted from Vertical to
Horizontal Configuration without Cutting Panels.
• Full Perimeter Base Rails with Built in Rigging Capabilities
• Galvanized Steel Drain Pan
• Reciprocating Compressor
• Single Stage Cooling
• Solid Core Liquid Line Filter Driers
• Microchannel Condenser Coil
• 75 MBH Input Aluminized Steel, Single Stage Gas Nominal Heat
• 1 HP Direct Drive Blower
• Unit Ships with 1" Throwaway Filters with a Standard Filter Rack That Will
Accept up to 2" Filters
• Single Point Power Connection
• Short Circuit Current: 5kA RMS Symmetrical
Standard Unit Controller: Simplicity Control Board
• An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag,
Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic
and Fault Code Display.
• Safety Monitoring - Monitors the High and Low -Pressure Switches, the
Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch
on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition
Failures, Safety Lockouts and Repeated Limit Switch Trips.
Warranty
• One (1) Year Limited Warranty on the Complete Unit
• Five (5) Year Warranty - Compressors and Electric Heater Elements
• Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers
Unitary Sales Tool v1 5 7 30
Information is subject to change without notice. Check local codes.
Printed 10f28/2013
Colemant
HEATING 8 AIR CONDITIONING
3-6 Ton Package
Single Package R -410A Air Conditioner
Page: 4
Project Name: All HI -Tech Unit Model #: ZS-04NO7AFAAA2
Quantity: 1 System: ZS-04NO7AFAAA2
Factory Installed Options
ZS-04NO7AFAAA2
Product Category:
Product Identifier:
Nominal Cooling Capacity:
Heat Type and Nominal Heat Capacity:
Airflow:
Voltage:
Installation Options:
Additional Options:
Product Generation:
• 2EE04703724 - Single Enthalpy
Economizer (Downflow or
Horizontal Unit) with Hood Kit
(50.0 lbs)
• 1 RD0410 - Barometric Relief
Damper with Hood Kit (Downflow
Unit or Duct Mounted) (6.0 lbs)
z
S
-04
N07
A
F
A
AA
2
Single Packaged R -410A Air Conditioner
13.0 SEER / 11.0 EER
4 Ton
Single Stage Cooling
75 MBH Input Aluminized Steel, Single Stage Gas Heat
1 HP Direct Drive Blower
1" Throwaway Filters
208/230-1-60
Microchannel Condenser Coil
Galvanized Steel Drain Pan
Field Installed Accessories
Unitary Sales Tool v1.5.7.30
Information is subject to change without notice. Check local codes.
Printed 1028/2013
Coleman@ 3-6 Ton Package Page:5
Single Package R -410A Air Conditioner
HEATING s RIR CONDmowNG
Project Name: All Hi -Tech Unit Model #: ZS-04NO7AFAAA2
Quantity: 1 System: ZS-04NO7AFAAA2
Consolidated Drawing
NOTES:
I. FOR OUTDOOR USE ONLY.
2. WEIGHTS SHOWN ARE FOR COOLING ONLY UNITS.
TONNAGE
U
N
I
OPERATING
WEIGHT (LBS)
CENTER OF GRAVITY
LOCATION (BASE UNIT)
4 PO NT CORNER LOADS (LBSI (BASE UNIT)
3. MIN. CLEARANCES TO BE:
T
(BASE UNIT)
X
Y
A
6
C
D
RIGHT SIDE: 24 [609,6]
LEFT SIDE: 24 [609,6] (LESS ECONOMIZER)
3
ZS
468 12121
33 )838,2)
18.25 [463,61
114 (52]
16 [35]
III [501
167 [161
36 [914,4] (WITH ECONOMIZER)
FRONT: 24 [609,6] (COOLING/ELECTRIC HEAT)
4
ZS
541 [245]
31.50 [800,1)
18.50 [469,9)
138 [631
85 [391
122 [551
196 [891
32 [812,8] (GAS HEAT)
REAR: 12 [304,8] (LESS ECONOMIZER)
5
ZS
569 (258)
37 [939,81
IS 1381]
105 (481
86 [391
110 1711
208 [941
36 1914,41 (WITH ECONOMIZER OR FIXED
AIR/MOTORIZED DAMPER)
6
IS
640 12901
37 1939,81
15 13811
118 [541
96 [441
192 (871
234 (106)
TOP: 12 [1828,81
BOTTOM: 0 [0]
31.62-_
[803,31
3
ZN
515 (2611
10 [10161
20 [5081
132 [601
125 [571
155 (101
164 [741
4. FOR SMALLER SERVICE AND OPERATIONAL CLEARANCES
CONTACT YOUR APPLICATION ENGINEERING DEPARTMENT.
6.12
[155,5)
4
ZN
585 [2651
40 (10161
20 [5081
131 [611
121 [581
158 [721
161 [161
5. DOWNFLOW DUCTS DESIGNED TO BE ATTACHED TO ACCESSORY 1.25
ROOF CURB ONLY. IF UNIT IS MOUNTED SIDE SUPPLY, IT [184,0]
18.26
[463,7)
-
5
ZN
590 [2681
40 110161
20 [5081
135 [611
128 [581
159 [721
168 [761
IS RECOMMENDED THAT THE DUCTS ARE SUPPORTED BY
CROSS BRACES, AS DONE ON ACCESSORY ROOF CURBS. 1.80 -
-
21.54 --
3
XA
575 [2611
39 1990,61
20 [5081
135 [611
121 [551
151 (691
168 [761
6. SIDE DUCT FLANGES ARE 0.815' [22.2] HIGH. [45,8)
BOTTOM DUCTS DO NOT HAVE FLANGES.
[699,6]
4
XA
585 [2651
39 [990,6)
20 15081
137 [621
121 [561
154 [101
171 [181
7. MINIMUM CONDENSATION TRAP HEIGHT SHALL BE 1.5 TIMES
+
REAR
THE LOWEST NEGATIVE STATIC.
5
XA
590 [2681
39 [990,61
20 [5081
138 [631
125 1511
155 [701
172 [781
8. DIMENSIONS IN [ ] ARE IN MILLIMETERS OR KILOGRAMS.
9. OPTIONAL COIL GUARD, GAS HEAT, ECONOMIZER HOOD,
DISCONNECT SWITCH, CONVENIENCE OUTLET, AND 5.51
OUTLET/INLET HOOD SHOWN. (140,01 i A
+
- 5.89
[149,61
B
® EXCEPT XA (HEAT PUMP) UNITS.
Rs----�-`-�
`
i
.-
-
� DIRECTION OF AIRFLOW POWER WIRING BOTTOM ENTRY
f 12.26 i
x (311,3] r
N s
u
11.50
[292,1]
; �/
rrd"E�"'.
I
l
[toxo /
0/A
3.00 II. 0
[76.2) [292,1)
952.00 [50,81
f ---I
17.50
� L''. ),50
CENTER OF GRAVITY
4.00
-
` ?tJ
FIGHT
Il
AETUNN /
11.50 19.08
[101,6]_=_£��`�
�[4d4,5]
\
-s`=
Il
III Ill
SUPPLY
0/A
y [292,1] [184,6]
1
8.23
[209,21
I
6.50
}
L 4.58
0
[165,11
17.50
7.62 [(16,31
I
11.06
6.18
[144,5] [193,6)
[281,0]
[164,7]
AS SUPPLY BOTTOM ENTRY 951.50 (38,11 N.O.
17.50
31.62
CONTROL WIRING BOTTOM ENTRY
00.88 [22,2]
32.09
[815,21
(0.50 [12,1] NPT AT GAS VALVE
VENT AIR OUTLET HOOD ®
[444,5]
REAR
[803,2]
PARTIAL VIEW)(RAIN
ECONOMIZER HOOD 951.97 N.O.
(OPTIONAL) [50,0]
DISCONNECT SWITCH
COVER (OPTIONAL)
X
OMBUSTION A R INLET HOOD
+
HOOD NOT
SHOWN IN THIS VIEW)
•
-
ACCESS
^
FAT Iii
CORP.
j
I
111110,
BLOWER
CONVENIENCE OUTLET
ACCESS
ACCESS
I
ij
ACCESS
COVER )OPTIONAL)
�
ACCESS
°
t 32.55
L
I
I
[69457]
illi
Pk
0[22821 N.O.i��u�����>v
I
■�[826,71
i
it .. 3._
tri
3.78
(96,0)
4.38 6.94
[111,11 [176,2]
14.88 \
18.58
(411,91
0.75 [19,1]
19.67
[499,7)
4.42
[112.31
- 31.89 AS SUPPLY ENTRY
[810,01 V51.63 [41,41 ®
[1139,81 OIL GUARD
(OPTIONAL)
FXGHT VIEW
2.55 - 82.19
PVC FPT [64,1] [2087,61
COND. DRAIN FRONT VIEW
LEFT VIEW
Information is subject to change without notice. Check local codes.
Printed 10/28/2013
Coleman@
HEATING A AIR CONDMONING
3-6 Ton Package
Single Package R -410A Air Conditioner
Page: 6
Project Name: All Hi -Tech
Unit Model #: ZS-04NO7AFAAA2
Quantity: 1
System: ZS-04NO7AFAAA2
((e)) DCL
Seismic Certification
SPECIAL SEISMIC CERTIFICATION
OF NON-STRUCTURAL
COMPONENTS AND SYSTEMS
CERTIFICATE OF COMPLIANCE
Johnson iyd
Controls
Dynamic Certification Laboratories has qualified the listed packaged rooftop units as CERTIFIED for seismic
applications in accordance with the following codes and standards:
CBC 2010, IBC 2009, ICC -ES AC -156 2010, ASCE 7-05
The following model designations are included in this certification. A complete list of certified models, options,
and installation methods are detailed in report number 90300-1108a by Dynamic Certification Laboratories,
provided by the equipment manufacturer upon request.
Unitary Product Group Packaged Rooftop Units (UPG)
Seismic Qualification Testing was conducted in accordance with and in strict adherence to the standards set
forth within the American Society of Civil Engineers (ASCE 7) by the independent approval agency, Dynamic
Certification Laboratories. The above referenced equipment is APPROVED for seismic applications when
properly installed and used as intended.
The basis of this certification is through testing of the active and energized components per AC156. This
certification covers multiple UPG brands, including York, Johnson Controls, Coleman, Luxaire, Evcon and Fraser -
Johnston.
The seismic values are obtained from the Maximum Considered Earthquake Short Period Spectral Response
Acceleration, Sds, as determined by the ASCE 7 seismic maps. Various installation locations/isolation
configurations are covered under this certification, limited by the Sds value stated in the following table. A
seismic importance factor, Ip, of 1.5 applies to this certification to include essential facility requirements and life
safety applications for post event functionality. The units are approved for both a rigid and flexible mount
configuration.
Maximum Design Sds Values of UPG Packaged Rooftop Units
Series
Model
Tons
Sds (g)
Fp/Wp
XP/XA/J0*XP/T0*
036, 048, 060
3, 4, 5
2.5
1.88
ZF/ZS/J0*ZF/JA*ZF/T0*
036, 048, 060, 072
3, 4, 5, 6
2.5
1.88
ZR/ZK/10*ZR/T0*
036, 048, 060
3, 4, 5
2.5
1.88
Page].of2
Dynamic Certification Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431 —ph: 775-358-5085 www.shaketest.com
Unitary Sales Tool v1.5.7.30
Information is subject to change without notice. Check local codes.
Printed 10Q8/2013
1C%mon@
HEATING 8 AIR CONDITIONING
3-6 Ton Package
Single Package R -410A Air Conditioner
Page: 7
Project Name: All HI -Tech
Unit Model #: ZS-04NO7AFAAA2
Quantity: 1
System: ZS-04NO7AFAAA2
Seismic Certification
SPECIAL SEISMIC CERTIFICATION
OF NON-STRUCTURAL
COMPONENTS AND SYSTEMS
CERTIFICATE OF COMPLIANCE
Johnson 4,.P
Controls
Table of Seismic Des gn Parameters
Site Class
F.
I,
ap
Rp
z/h
D
1.0
1.5
2.5
6.0
1.0
Site and Project Requirements
It is the responsibility of the Design Professional of Record to:
• Provide engineering for the anchorage and restraint of the unit
• Validate Cerftficafton Design Parameters with actual site condiftons
• Provide engineering of all equipment support structures
• Confirm component configurafton
Cerftficafton Issued by: Dynamic Cerftficafton Laboratories
Document Control Number: 90300-1108a-1
Issue Date: 12/19/11
Dr. Ahmad Itani, SE
Dynamic Cerftficafton Laboratories
i“ (5ef
Randy Forristall
YORK Unitary Engineering
Johnson Controls, Incorporated
Page 2 of 2
Dynamic Cerftficafton Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431— ph: 775-358-5085 www.shaketest.com
Unitary Sales Tool v1.5.7.30
Information is subject to change without notice. Check local codes.
Printed 1028/2013
Date
10/28/2013
Project Name
All Hi -Tech
Project Number
Client / Purchaser
Guide Specification Summary Page
HEATING & AIR CONDITIONING
Product Series Models and Unit Tags
3 6 TonPackage
.',4S-04N07AFAAA2
Unitary Sales Tool v1.5.7.30
Information is subject to change without notice. Check local codes. Printed 10128/2013
HEATING & AIR CONDITIONING
Guide Specification for
Apex 3-6 Ton Single Package
Page: 9
GENERAL
Units shall be manufactured by Johnson Controls Unitary
Products in an ISO 9001 certified facility. Coleman 3-6
Ton package units are convertible single package units.
Although the units are primarily designed for curb
mounting on a roof, they can also be slab -mounted at
ground level or set on steel beams above a finished roof.
Cooling only, cooling with gas heat and cooling with
electric heat models are available with a wide variety of
factory -mounted options and field -installed accessories
to make them suitable for almost every application. All
units are self-contained and assembled on full perimeter
base rails with holes in the four corners for overhead
rigging. Every unit is completely piped, wired, charged
and tested at the factory to simplify the field installation
and to provide years of dependable operation. All
models (including those with an economizer) are suitable
for either bottom or horizontal duct connections. Models
with power exhaust are suitable for bottom duct
connections only. For bottom duct, remove the sheet
metal panels from the supply and return air openings
through the base of the unit. For horizontal duct, remove
the supply and return air panels on the rear of the unit.
All non -Scroll compressors include crankcase heaters and
all compressors have internal pressure relief. Every
refrigerant circuit includes a liquid line filter -drier, a
discharge line high pressure switch and a suction line with
a freezestat and low pressure/loss of charge switch. The
unit control circuit includes a 75 VA transformer, a 24 -volt
circuit breaker and a relay board with a compressor
lockout circuit, a terminal strip for thermostat wiring, plus
an additional set of pin connectors to simplify the interface
of additional field controls. All models are CSA listed. All
models include a 1 -year limited warranty on the complete
unit. Compressors and electric heater elements carry a 5 -
year warranty. Aluminized steel and Stainless steel tubular
heat exchangers carry a 10 -year warranty.
DESCRIPTION
Units shall be factory -assembled, single packaged,
Electric Cooling/Gas Heat, Electric Cooling/Optional
Electric Heat, Heat Pump/Optional Electric Heat are
designed for outdoor mounted installation.
The 3 ton, 4 ton and 5 ton units shall have minimum SEER
rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6
Ton Cooling only or Cooling with Electric Heat shall have
11.2 EER, 6 Ton Cooling with Gas Heat shall have 11.0
EER. They shall have built-in field convertible duct
connections for down discharge supply/return or horizontal
discharge supply/return, and be available with factory
installed options or field installed accessories. The units
shall be factory wired, piped, charged with R -410A
refrigerant and factory tested prior to shipment. All unit
wiring shall be both numbered and color coded. All units
the cooling performance shall be rated in accordance with
DOE and AHRI test procedures. Units shall be CSA listed,
classified to ANSI Z21.47, UL 1995/CSA No. 236
standards.
UNIT CABINET
Unit cabinet shall be constructed of galvanized steel, with
exterior surfaces coated with a non -chalking, powdered
paint finish, certified at 1000 hours salt spray test per
ASTMB117 standards. Indoor blower section shall be
insulated with a minimum 1/2" thick insulation, coated on
the airside. Aluminum foil faced insulation shall be used in
the furnace compartment and be fastened with ridged
fasteners to prevent insulation from entering the air
stream. Cabinet panels shall be "large" size, easily
removable for servicing and maintenance. Full perimeter
base rails shall be provided to assure reliable transit of
equipment, overhead rigging and proper sealing on roof
curb applications. Disposable 1" filters shall be furnished
and be accessible through a removable access door,
sealed airtight. Units filter track shall be designed to
accommodate either 1" or 2" filters. Fan performance
measuring ports shall be provided on the outside of the
cabinet to allow accurate air measurements of evaporator
fan performance without removing panels or creating air
by-pass of the coils. Condensate pan shall be internally
sloped and conform to ASHRAE 62-89 self -draining
standards. Condensate connection shall be a minimum of
3/4" I.D. female and be a ridged mount connection.
INDOOR (EVAPORATOR) FAN ASSEMBLY
The indoor fan shall be a factory installed direct -drive or
belt -drive assembly that includes an adjustable pitch motor
pulley. Job site selected (B.H.P.) brake horsepower shall
not exceed the motors nameplate horsepower rating, plus
the service factor. Units shall be designed not to operate
above service factor. Fan wheel shall be double -inlet type
with forward -curved blades, dynamically balanced to
operate smoothly throughout the entire range of operation.
Airflow design shall be constant air volume. Bearings shall
be sealed and permanently lubricated for longer life and
no maintenance.
OUTDOOR (CONDENSER) FAN ASSEMBLY
The outdoor fan shall be of the direct -driven propeller type,
discharge air vertically, have aluminum blades riveted to a
corrosion resistant steel spider bracket and shall be
dynamically balanced for smooth operation. The outdoor
fan motor shall be totally enclosed with permanently
lubricated bearings, internally protected against overload
conditions and staged independently.
Unitary Sales Tool v1.5.7.30
Information is subject to change without notice. Check local codes.
Printed 10/28/2013
HEATING A AIR CONDITIONING
Guide Specification for
Apex 3-6 Ton Single Package
Page: 10
REFRIGERANT COMPONENTS
Compressors:
a. Shall be internally protected with internal high-
pressure relief and over temperature protection.
b. Shall have internal spring isolation and sound
muffling to minimize vibration and noise, and be
externally isolated on a dedicated, independent
mounting.
Coils:
a. Evaporator coils shall have aluminum plate fins
mechanically bonded to seamless internally
enhanced copper tubes with all joints brazed. Special
Phenolic coating shall be available as a factory
option.
b. Evaporator coils shall be of the direct expansion,
draw-thru design.
c. Condenser coils shall have aluminum plate fins
mechanically bonded to seamless internally
enhanced copper tubes with all joints brazed or
Micro -Channel aluminum tube, aluminum fins.
d. Condenser coils shall be of the direct expansion,
draw-thru design.
Refrigerant Circuit and Refrigerant Safety Components
shall include:
a. Independent fixed -orifice or thermally operated
expansion devices.
b. Filter drier/strainer to eliminate any moisture or
foreign matter.
c. Accessible service gage connections on both suction
and liquid lines to charge, evacuate, and measure
refrigerant pressure during any necessary servicing
or troubleshooting, without losing charge.
d. The refrigeration system shall provide at least 15°F of
sub -cooling at design conditions.
Unit Controls:
a. Unit shall be complete with self-contained low -voltage
control circuit protected by a resettable circuit breaker
on the 24 -volt transformer side.
b. Unit shall incorporate a lockout circuit which provides
reset capability at the space thermostat or base unit,
should any of the following standard safety devices
trip and shut off compressor.
c. Loss-of-charge/Low-pressure switch.
d. High-pressure switch.
e. Freeze -protection thermostat, evaporator coil.
f. Unit shall incorporate "AUTO RESET" compressor
over temperature, over current protection.
g.
Unit shall operate with conventional thermostat
designs and have a low voltage terminal strip for
easy hook-up.
h. Unit control board shall have on -board diagnostics
and fault code display.
i. Standard controls shall include anti -short cycle and
low voltage protection, and permit cooling operation
down to 0°F.
Control board shall monitor each refrigerant safety
switch independently.
k. Control board shall retain last 5 fault codes in non
volatile memory which will not be lost in the event of a
power loss.
J.
GAS HEATING SECTION (SINGLE STAGE)
Shall be designed with induced draft combustion with
post purge logic, energy saving direct spark ignition, and
redundant main gas valve. Venter wheel shall be
constructed of stainless steel for corrosion resistance.
The heat exchanger shall be of the tubular type,
constructed of T1-40 aluminized steel for corrosion
resistance and allowing minimum mixed air entering
temperature of 25°F. Burners shall be of the inshot type,
constructed of aluminum coated steel and contain air
mixture adjustments. All gas piping shall enter the unit
cabinet at a single location through either the side or
curb without any field modifications. Integrated control
boards shall provide timed control of evaporator fan
functioning and burner ignition. Heating section shall be
provided with the following minimum protection.
a. Primary and auxiliary high-temperature limit switches.
b. Induced draft motor speed sensor.
c. Flame roll out switch.
d. Flame proving controls.
e. If any of the above safety devices trip, a LED (light -
emitting diode) indicator shall flash a diagnostic code
that indicates which safety switch has tripped.
NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage,
40% Capacity 2nd Stage.
UNIT OPERATING CHARACTERISTICS
Unit shall be capable of starting and running at 125°F
outdoor temperature, exceeding maximum load criteria
of AHRI Standard 210/240. The compressor, with
standard controls, shall be capable of operation down to
0°F outdoor temperature. Unit shall be provided with fan
time delay to prevent cold air delivery before heat
exchanger warms up (Gas heat only).
Unitary Sales Tool v1.5.7.30
Information is subject to change without notice. Check local codes.
Printed 10/28/2013
HEATING & AIR CONDITIONING
Guide Specification for
Apex 3-6 Ton Single Package
Page: 11
ELECTRICAL REQUIREMENTS
All unit power wiring shall enter unit cabinet at a single
factory provided location and be capable of side or
bottom entry, to minimize roof penetrations and avoid
unit field modifications. Separate side and bottom
openings shall be provided for the control wiring.
STANDARD LIMITED WARRANTIES
• Compressor 5 Years
• Heat Exchanger 10 Years
• Electric Heat Element 5 Years
• Other Parts 1 Year
ADDITIONAL FACTORY INSTALLED OPTIONS
FIELD INSTALLED OPTIONS
• Single Input Electronic Enthalpy Economizer —
Includes a slide -in / plug-in damper assembly with
fully modulating spring -return motor actuator capable
of introducing up to 100% outdoor air with nominal
1% leakage type dampers. The enthalpy system
contains one sensor that monitors the outdoor air and
determines when the air is cool enough and dry
enough to provide free cooling. The rain hood is
painted to match the basic unit and must be field -
assembled before installing.
• Barometric Relief Damper — This damper accessory
can be used to relieve internal building air pressure
on units with an economizer without power exhaust.
This accessory includes a rain hood, a bird screen
and a fully assembled damper. With bottom duct
connections, the damper should be mounted over the
opening in the return air panel. With horizontal
ductwork, the accessory should be mounted on the
return air duct.
Unitary Sales Tool v1.5.7.30
Information is subject to change without notice. Check local codes.
Printed 10/28/2013
FILE C
DESCRIPTION
DCG MODEL
SHOWN
YORK Sunline 2000 units are convertible single package air
conditioners with a common cabinet and a common roof curb
for the 3, 4, 5 and 6 ton sizes. The units were designed for light
commercial and commercial applications. They can easily be
installed on a roof curb, slab, roof jack or frame.
All units are self-contained and assembled on rigid full
perimeter base rails with fork lift slots on three sides and holes
for overhead rigging. Every unit is completely piped, wired,
charged and tested at the factory to provide for a quick and
easy field installation.
The units are available in cooling only, and cooling with gas heat.
Electric heaters are available as field -installed accessories.
The cabinet is constructed of galvanized steel, painted with long
lasting, durable, and aesthetically pleasing power paint. Paint
finish meets 750 hour salt spray tests per ASTM -B117 standards.
All models include a 5 -year limited warranty on scroll
compressors and electric heating elements, a 10 -year limited
warranty on gas-fired heat exchangers and a 1 -year limited
warranty on all replacement parts.
FEATURES
COMMON FOOTPRINT/COMMON CABINET - All model
sizes and configurations share a common cabinet and a
common roof curb. The installer has the flexibility of setting one
curb and placing the proper tonnage unit on that curb after the
internal load has been determined. He can even decide
between gas or electric heat after the curb has been set
HIGH EFFICIENCY - All units have a high cooling efficiency,
and gas / electric models have a minimum AFUE of 80%. All
efficiencies exceed legislated minimum levels and provide low
operating costs.
CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom
duct openings are covered when they leave the factory. If a side
supply / side return is desired, you simply remove the two side
duct covers from the outside of the unit and discard them. If a
bottom supply / bottom return is desired, you simply remove the
U k'
530.18-TG1Y (500)
12YORIC
SINGLE PACKAGE
AIR-COOLED
AIR CONDITIONERS
D4CE 036, 048, 060 & D2CE 072
D7CG 036, 048, 060 & D2CG 072
3, 4 AND 5 NOMINAL TONS (10 SEER)
AND 6 NOMINAL TONS (9 EER)
SUNLINE 2000TCIYY OF TUKW ILA
NOV 1:2 2013
PERMIT CENTER
two knockout panels from the base of the unit and discard them.
No panel cutting or swapping is required! Convertible airflow
design allows maximum field flexibility and minimum inventory.
Economizers may be used on either bottom and side duct
applications with no modifications required.
FACTORY -INSTALLED OPTIONS - Economizers can be
installed at the factory. The economizers are shipped installed
and wired. Only the rain hood needs to be field assembled and
installed. Field labor dollars can be saved by having the
components arrive already installed.
Adjustable belt drive blowers are available on all models from
the factory for complete airflow flexibility.
FIELD -INSTALLED ACCESSORIES - Accessories were
designed for quick and easy installation. The motorized damper
and economizers simply slide in, and electrical connections are
made by modular plugs. Electric heaters mount easily, and
knockouts are provided in the internal partitions to connect the
elements to the control box single point kit.
The motorized air damper includes a slid-in/plug-in damper
assembly with a rainhood and filters. The outdoor air dampers
open when the indoor fan motor is energized. The damper is
capable of providing 0% through 100% of outdoor return air
opening.
The manual outdoor damper provides 0% through 35% or 0%
through 100% of return air opening (field adjustable). Designed
for duct mounted side or bottom supply/return applications.
Includes rain hood assembly and filter.
The 14" high roof curb is shipped knocked down. An insulated
deck is not required because the bottom of the unit is insulated.
Low ambient controls are available to provide stable unit
operation at outdoor temperatures down to 0°F.
Propane, high altitude and low NOx kits are also available to
cover all gas heating applications.
WIDE RANGE OF INDOOR AIRFLOWS - All 3, 4 and 5 -ton
models operate over a wide range of design conditions with a
Cont'd.
530.18 -TG I Y
FEATURES - CONT'D.
3 -speed direct -drive fan motor. The 6 -ton unit has a single
speed direct -drive fan motor. Belt -drive blowers are also
available on all 3, 4, 5 and 6 -ton models.
FULL PERIMETER BASE RAILS - The permanently attached
base rails provide a solid foundation for the entire unit and
protect the unit during shipment. The rails provide fork lift
access from 3 sides, and rigging holes are also provided so
that an overhead crane can be used to place the units on a roof.
SYSTEM PROTECTION - Internal overload protection are
standard on all scroll compressors. Every unit has a liquid line
filter -drier, high and low pressure/lose at charge switches and a
suction line freezestat to protect all system components. All units
will provide cooling at ambient temperatures down to 45°F
UTILITY CONNECTIONS MADE EASY - Gas and electric
utility knockouts are provided in the unit base as well as the
side of the unit. A clearly identified location is provided to mount
a field supplied electrical disconnect switch. Utility connections
can be made quickly and with a minimum amount of field labor.
SIMPLE CONTROL CIRCUIT - A low voltage printed circuit
board contains a scroll compressor lockout indicator light and
a low voltage terminal strip. An additional set of pin connectors
is also provided to simplify the field interface of external
controls. Mate -n -lock plug connectors are used where line and
low voltage wires pass thru internal bulkheads. This allows for
easier troubleshooting and component replacement. The
electrical control box is not located in the scroll compressor
compartment so the access cover can be removed for
troubleshooting without affecting the normal system operating
pressures. All wiring internal to the unit is color/number coded.
AIR FILTERS - Units are shipped with 1" disposable filters. The
unit filter racks can accommodate 1" or 2" filters without any
modifications.
YORK'
SUNLINE 2000TM
LOW VOLTAGE RELAY BOARD 20 GAUGE ALUM NIZED STEEL
AND TERMINAL STRIP TUBULAR HEAT EXCHANGER
ELECTRICAL DISCONNECT
MOUNTING LOCATION
(Field Installed)
ECONOMIZER HOOD
DIRECT DRIVE
BLOWER MOTOR
(Belt Drive Option
also available on
some models)
ELECTRIC HEAT ACCESSORY
LOCATION (Elec/Elec Units)
POWER VENTER MOTOR
OUTDOOR AIR OPENING
FOR SLIDE-IN/PLUG IN
INTERNAL ECONOMIZER
(ACCESSORY)
SIDE RETURN AIR
DUCT OPENING
(Return Air & Supply Air
Side by Side)
BOTTOM RETURN AIR
DUCT OPENING
(Return Air & Supply Air
Side by Side)
3/4" PVC FEMALE
CONDENSATE DRAIN
KNOCKOUTS FOR SIDE
POWER AND CONTROL
ENTRY
TERMINAL BLOCK
(For Single Point Power
Supply on Elec/Elec Units)
KNOCKOUT FOR BOTTOM
GAS SUPPLY ENTRY
KNOCKOUT FOR BOTTOM
POWER ENTRY
COPPER TUBE /
ALUMINUM FIN
CONDENSER COIL
HIGH EFFICIENCY
SCROLL COMPRESSORS
BASE RAILS
WITH FORKLIFT SLOTS
AND LIFTING HOLES
KNOCKOUT FOR SIDE
GAS SUPPLY ENTRY
MODEL DCG
(Gas Heating)
TABLE OF CONTENTS
Description
Features 1
Ratings 3
Sound Power Ratings for Supply Air Blower 3
Physical Data 3
Cooling Capacities - 3 Ton 4
Cooling Capacities - 4 Ton 5
Cooling Capacities - 5 Ton 6
Cooling Capacities - 6 Ton 7
Blower Performance - 3 & 4 Ton w/Belt-Drive 8
Blower Performance - 5 & 6 Ton w/Belt-Drive 9
Blower Performance - 3 - 6 Ton w/Direct-Drive 10
Option and Accessories 10
1 Static Resistances 11
Motor and Drive Data 11
Electrical Data - Basic Units 11
Elec. Data-Clg./Elec. Htg.
Elec. Data-Clg./Elec. Htg.
Elec. Data-Clg./Elec. Htg.
Elec. Data-Clg./Elec. Htg.
Field Wiring
Unit Dimensions
Roof Curb Dimensions
3 & 4 Ton w/Direct-Drive 12
5 & 6 w/Direct-Drive 13
3 & 4 w/Belt-Drive 14
5 & 6 w/Belt-Drive 15
16
17 & 18
19
Component Weights and Center of Gravity 19
Typical Applications 20
Mechanical Specifications 21
2 Unitary Products Group
RATINGS
CAPACITY RATINGS - Cooling / Electric Heatin
MODEL
ARI RATINGS'
NOMINAL
ELECTRIC HEAT CAPACITY3
(KV
STANDARD
CFM
COOLING CAPACITY
80 / 67-95°F
SOUND
RATING2
(dbels)
MBH
SEER
EER
240V
480V
600V
DCE036
36.0
10.00
9.10
82
5 7, 10,
15&20
7, 10,
15&20
10,
15&20
1.300
DCE048
47.4
10.00
9.00
82
5 7, 10,
15&20
7, 10,
15&20
10,
15&20
1.700
DCE060
59.0
10.00
9.10
82
5, 7, 10,
15,20 &30
7, 10, 15
20 & 30
10, 15,
20 &30
2.100
DCE072
72.0
-
9.00
84
5, 7, 10,
15,20 &30
7, 10, 15,
20 &30
10, 15,
20 &30
2.400
CAPACITY RATINGS - Cooling / Gas Heating
530.18 -TG 1 Y
- Not ARI Usted.
MODEL
ARI RATINGS1
GAS HEAT CAPACITY
STANDARD
CFM
COOLING CAPACITY
80 / 67-95°F
SOUND
RATING2
(dbels)
INPUT
(MBH)
(MBH)
AFUE
(%)
•OUTPUT
S.S.E.
(%)
TEMP.
RISE
(°F)
GAS
LE
MBH
SEER
EER
DCG036N040
DCG036N079
36.0
36.0
10.00
10.00
9.10
9.10
82
82
50
100
40
79
80.9
80.5
81.6
80.8
15-45
40-70
1/2
1/2
1.300
DCG048N060
DCG048N099
47.4
47.4
10.00
10.00
9.00
9.00
82
82
75
125
59
99
80.9
80.3
81.6
80.6
25-55
45-75
1/2
1/2
1.700
DCGO6ON079
DCGO6ON099
59.0
59.0
10.00
10.00
9.10
9.10
82
82
100
125
79
99
80.5
80.3
80.8
80.6
25-55
35-65
1
1/2
2.100
DCG072N079
72.0°
-9.00
2,000
84
100
79
80.5
80.8
25-55
1/2
71
DCG072N099
72.0°
-
9.00
84
125
99
80.3
80.6
35-65
1/22.400
87
'Certified h accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. 'Rated in accordance with ARI Standard 270. 'Heaters are available as accessories - a0 with single
point power supply...Certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/360.
SEER - Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.
EER - Energy Efficiency Ratio - the cooling capacity in Btu's per hour (Stull) divided by the power input in watts at any given set of rating conditions, expressed in BTUH per watt (BTUH/watt).
AFUE - Annual Fuel Utilization Efficiency - determined in accordance with DOE test procedure.
S.S.E. - Steady State Efficiency. (Percent Output).
SOUND
PQWER
RATINGS
FOR SUPPLY AIR BLOWER
MODEL
CFM
ESP
BLOWER
SOUND POWER (dB 10-12 watts)
OCTAVE BAND CENTERLINE FREQUENCY (Hz)
SIM_dB
dB (A)
(A)
1
IWG
SPEED
KW
63
125
250
500
1,000
2,000
4,000
8,000
036
1,200
0.60
LOW
0.60
84
84
74
67
69
62
57
52
74
41
048
1,600
0.55
HIGH
0.80
85
85
75
68
70
63
58
53
75
42
060
2,000
0.45
HIGH
1.00
86
86
76
69
71
64
59
54
76
43
072
2,200
0.30
HIGH
1.35
87
87
77
70
72
65
60
55
77
44
At a distance of 10 ft.from the blower.
NOTE: These values have been derived using a model of sound propagation, measuring the indoor ambient sound evels ten feet from the source. The dBA values provided are for reference
only. Calculation of dBA values cover matters of system design and application. This constitutes an exception to any specification or guarantee requiring a CBA value or sound data in
any other form than sound power level ratings.
PHYSICAL DATA - BASIC UNITS
MODEL
EVAPORATOR
BLOWER
EVAPORATOR
COIL
COMPRESSOR
TYPE
CONDENSER
FAN
CONDENSER
COIL
AIR
FILTERS
(SEE NOTE)
CHARGE
CENTRIFUGAL
(Dia. x Wd. in.)
FAN MOTOR HP
(DIRECT -DRIVE)
FAN MOTOR HP
(BELT -DRIVE)
ROWS DEEP
FINS PER INCH
FACE AREA
(Sq. Ft.)
HERMETICALLY
SEALED
PROPELLER
DIA. (in.)
FAN MOTOR HP
NOM. CFM TOTAL
ROWS DEEP
FINS PER INCH
FACE AREA
(Sq. Ft.)
QUANTITY
PER UNIT
(15" X 20" X 1")
QUANTITY
PER UNIT
(14" X 25" X 1")
TOTAL FACE
_AREA (sq. ft.)
REFRIGERANT
R-22 (lbs./oz.)
036
12 x 10
1/2
11/2
3
13
3.6
SCROLL
TYPE
24
1/4
3,400
1
16
17.1
2
1
6.3
5/8
048
12 x 10
3/4
11/2
3
13
4.3
24
1/4
3,400
1
16
17.1
2
1
6.3
6/8
060
12 x 10
1
11/2
3
13
5.1
24
1/4
3,400
1
22
17.1
2
1
6.3
6/8
072
12 x 11
1
11/2
4
13
5.1
24
1/4
3,300
2
16
16.7
2
1
6.3
10/0
NOTE: Filter racks are adapted for 1" or 2" thick fliers.
Unitary Products Group
3
530.1,8-TGfY
COOLING CAPACITIES - 3 TON (DCE / DCG036)
Air On
Evaporator
Coil
Temperature of Air on Condenser Coil
85°F
95°F
Total
Cap.1
MBH
Powe[
Input`
KW
Sensible Capacityl, MBH
Total
Cap.1
MBH
Powe
Input'
KW
Sensible Capac'ty1, MBH
CFM
WB
°F
Entering
Dry Bulb, °F
Entering Dry Bulb, °F
86
83
80
77
74
71
68
86
83
80
77
74
71
68
72
45
3.1
35
30
26
21
17
-
-
43
3.3
35
30
26
21
17
-
-
1750
67
43
3.0
43
38
34
29.
25
20
16
41
3.3
41
38
34
29
25
21
16
62
39
3.0
39
39
39
34
30
25
21
36
3.3
36
36
36
32
27
23
18
57
40
2.9
40
40
40
35
31
26
22
38
3.2
38
38
38
33
29
24
20
72
44
3.1
31
28
24
20
16
-
-
42
3.3
31
27
23
20
16
-
-
1475
67
41
3.0
39
35
31
27
23
19
16
39
3.3
37
35
31
27
23
19
15
62
38
3.0
38
38
37
33
29
25
21
36
3.3
36
36
35
31
27
23
19
57
39
2.9
39
39
39
35
31
27
23
37
3.2
37
37
36
32
28
25
21
72 _
42
3.1
28
25
22
18
15
-
-
41
3.3_
28
24
21
18
14
-
-
1200
-67 .
40
3.0
35
32
28
25
22
18
15
98_._
3.2
34
31
28..
25
21
18
15
62
36
3.0
36
36
35
31
28
25
21
35
3.3
35
35
34
30
27
24
20
57
37
2.9
37
37
37
34
31
27
24
36
3.2
36
36
35
32
28
25
22
72
41
3.1
26
23
20
17
14
-
-
39
3.2
26
23
20
17
14
-
-
1050
67
38
3.0
32
30
27
24
21
18
15
37
3.2
32
29
26
23
20
17
14
62
35
3.0
35
35
33
30
27
24
21
33
3.2
33
33
31
28
25
22
20
57
36
2.9
36
36
35
32
29
26
23
34
3.2
34
34
32
30
27
24
21
72
39
3.1
24
21
19
16
14
-
-
38
3.2
23
21
18
16
13
-
-
900
67
37
3.0
30
27
25
22
20
17
15
36
3.2
29
26
24
21
19
16
14
62
34
3.0
34
33
30
28
25
23
20
32
3.2
32
31
29
26
24
21
19
57
34
2.9
34
34
33
30
27
25
22
33
3.1
33
33
30
27
25
22
20
Air On
Evaporator
Coil
Temperature of Air on Condenser Coil
105°F
115°F
Total
Powe
Input
KW
Sensible Capac'ty1, MBH
Total
Cap.1
MBH
Powe
Input'
KW
Sensible Capactyl, MBH
CFM
WB
°F
Cap.1
MBH
Entering Dry Bulb, °F
Entering Dry Bulb, °F
86
83
80
77
74
71
68
86
83
80
77
74
71
68
72
41
3.7
34
29
25
20
16
-
-
39
4.1
33
28
24
19
15
-
-
1750
67
38
3.7
38
37
33
28
24
19
15
36
4.0
36
36
32
27
23
18
14
62
34
3.7
34
34
34
30
25
21
16
32
4.0
32
32
32
27
23
18
14
57
35
3.6
35
35
35
31
26
22
17
33
4.0
33
33
33
28
24
19
15
72
40
3.7
30
26
23
19
15
-
-
38
4.1
30
26
22
18
14
-
-
1475
67
37
3.6
36
34
30
26
22
18
14
35
4.0
34
33
29
25
21
17
13
62
33
3.7
33
33
33
29
25
21
17
31
4.0
31
31
31
27
23
19
15
57
34
3.6
34
34
34
30
26
22
18
32
4.0
32
32
32
28
24
20
16
72
39
3.7
27
24
20
17
14
-
-
37
4.1
26
23
20
16
13
-
-
1200
67
36
3.6
34
30
27
24
20
17
14
34
4.0
33
30
26
23
20
16
13
62
32
3.6
32
32
32
29
25
22
19
30
4.0
30
30
30
27
24
20
17
57
33
3.6
33
33
33
29
26
23
19
31
3.9
31
31
31
27
24
21
17
72
37
3.6
25
22
19
16
13
-
-
36
4.1
24
21
18
15
12
-
-
1050
67
35
3.6
31
28
25
22
19
16
13
32
4.0
30
27
24
21
18
15
12
62
31
3.6
31
31
29
27
24
21
18
29
4.0
29
29
28
25
22
19
16
57
32
3.5
32
32
30
27
24
21
18
30
3.9
30
29
28
25
22
19
16
72
36
3.6
22
20
17
15
12
-
-
34
4.0
21
19
16
14
11
-
-
900
67
33
3.6
28
25
23
20
18
15
13
31
4.0
27
24
22
19
17
14
11
62
30
3.6
30
29
27
24
22
19
17
28
4.0
28
28
25
22
20
17
15
57
31
3.5
31
30
28
25
22
20
17
28
3.9
28
28
25
23
20
17
15
I These capacities are gross ratings. For net capacity, determine the KW of the supply air dower moto from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the
motor heat and deduct this heat from the gross capacity of the unit.
2 These ratings include the compressor and the condenser fan motors but not the supply air dower motor. The total condenser fan motor power input is 0.36 KW Refer to the Blower Performance
Table for the KW of the supply air blower motor.
NOMINAL RATING
4
ALL SENSIBLE CAPACITY
Unitary Products Group
530.18 -TG 1 Y
COOLING CAPACITIES - 4 TON (DCE / DCG048)
Air On
Evaporator
Coil
Temperature of Air on Condenser Coil
85°F
95°F
Total
Cap.1
Powe
Input
Sensible Capac'ty1, MBH
Total
Cap.1
Powe
Input
Sensible Capacityl, MBH
CFM
WB
Entering
Dry Bulb, °F
Entering
Dry Bulb, °F
86
83
80
77
74
71
68
86
83
80
77
74
71
68
°F
MBH
KW
MBH
KW
31
72
60
4.1
44
39
33
28
23
-
-
60
4.5
44
_
39
33
28
23
-
-
2000
67
55
4.1
53
48
42
37
32
26
21
52
4.5
52
47
42
36
31
25
20
45
62
51
4.0
51
51
51
45
40
34
29
48
4.4
48
48
48
42
37
32
26
44
57
49
3.9
49
49
49
44
39
33
28
47
4.3
47
47
47
42
36
31
26
29
72
58
4.1
41
36
31
26
21
-
-
57
4.5
41
36
31
26
21
-
-
1800
67
53
4.1
49
45
40
35
30
25
20
50
4.5
49
44
39
34
29
24
19
43
62
49
4.0
49
49
48
43
38
33
28
46
4.4
46
46
46
41
36
31
26
43
57
47
3.9
47
47
47
43
38
33
28
45
4.3
45
45
45
40
36
31
26
28
72 _
56
4.1
38
34
29
25
20
-
-
55
4.6
38
33
29
24
20
-
-
35
67
51
4.1
46
41
37
32
28
24
19
48
4.5
45
40
36
31
27
23
18
1600
37
33
28
24
39
5.3
39
39
39
35
30
26
21
57
41
4.8
41
41
41
62
47
4.0
47
47
45
41
36
32
27
44
4.4
44
44
44
40
35
31
26
26
57
46
3.9
46
46
46
41
37
32
28
44
4.4
44
44
44
39
35
30
26
33
72
54
4.1
35
31
27
23
19
-
-
53
4.5
35
31
27
23
19
-
-
1400
67
49
4.1
42
38
34
30
26
22
19
47
4.5
41
38
34
30
26
22
18
38
62
45
4.0
45
45
42
38
34
30
26
43
4.4
43
43
41
37
33
29
25
23
57
44
3.9
44
44
43
39
35
31
27
42
4.3
42
42
41
37
33
29
25
30
72
52
4.1
32
29
25
22
18
-
-
51
4.5
32
28
25
21
18
-
-
1200
67
47
4.1
39
35
32
28
25
21
18
45
4.4
38
35
31
28
24
21
17
35
62
43
4.0
43
43
39
36
32
29
25
41
4.3
41
41
38
35
31
28
24
57
42
3.9
42
42
39
36
_ 32
29
25
41
4.3
41
41
38
34
31
27
24
Air On
Evaporator
Coil
Temperature of Air on Condenser Coil
105°F
115°F
Total
Cap.1
MBH
Powe
Input
KW
Sensible Capac'ty1, MBH
Total
Cap.1
MBH
Powe
Input
KW
Sensible Capacityl, MBH
CFM
WB
°F
Entering
Dry Bulb, °F
Entering
Dry Bulb, °F
86
83
80
77
74
71
68
86
83
80
77
74
71
68
72
56
5.1
42
37
31
26
21
-
-
53
5.6
40
35
29
24
19
-
-
2000
67
49
5.0
49
46
40
35
29
24
19
46
5.5
46
44
39
33
28
23
17
62
45
4.9
45
45
45
39
34
28
23
41
5.4
41
41
41
36
30
25
20
57
44
4.9
44
44
44
39
33
28
22
41
5.4
41
41
41
35
30
25
19
72
55
5.0
39
34
29
24
20
-
-
52
5.5
38
33
28
23
18
-
-
1800
67
48
5.0
47
43
38
33
28
23
18
45
5.4
45
42
37
32
27
22
17
62
43
4.9
43
43
43
38
33
28
23
40
5.4
40
40
40
35
30
26
21
57
43
4.9
43
43
43
38
33
28
23
40
5.4
40
40
40
35
30
25
20
72
53
5.0
36
32
28
23
19
-
-
51
5.5
35
31
26
22
17
-
-
1600
67
46
4.9
44
40
35
31
26
22
17
44
5.4
44
39
35
30
26
21
17
62
42
4.9
42
42
42
37
33
28
24
39
5.3
39
39
39
35
30
26
21
57
41
4.8
41
41
41
37
32
28
23
39
5.3
39
39
39
34
30
25
21
72
51
5.0
33
29
26
22
18
-
-
48
5.5
32
28
24
20
16
-
-
1400
67
44
4.9
41
37
33
29
25
21
17
42
5.3
40
36
32
28
24
20
16
62
40
4.8
40
40
39
35
31
27
23
37
5.3
37
37
36
32
28
24
20
57
40
4.8
40
40
38
34
30
26
22
37
5.3
37
37
36
32
28
24
20
72
49
4.9
30
27
23
20
16
-
-
46
5.4
29
26
22
19
15
-
-
1200
67
42
4.9
37
34
30
27
23
20
16
39
5.3
36
33
29
26
22
19
15
62
38
4.8
38
38
36
32
29
25
22
35
5.3
35
35
33
29
26
22
19
57
38
4.8
38
38
35
32
28
25
21
35
5.3
35
35
33
29
26
22
19
I These capacities are gross ratings. For net capacity, determine the KW of the suppy air Dower moto from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the
motor heat, and deduct this heat from the gross capacity of the unit.
2 These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36 KW. Refer to the Blower Performance
Table for the KW of the supply air blower motor.
NOMINAL RATING
Unitary Products Group
ALL SENSIBLE CAPACITY
5
530.1d8-TGiY
COOLING CAPACITIES - 5 TON (DCE / DCG060)
Air On
Evaporator
Coil
Temperature of Air on Condenser Coil
85°F
95°F
Total
Cap.1
MBH
Powe
Input
KW
Sensible Capacityl, MBH
Total
Cap.1
MBH
Powe
Input
KW
Sensible Capacityl, MBH
CFM
B
°F
Entering
Dry Bulb, °F
Entering
Dry Bulb, °F
86
83
80
77
74
71
68I
86
. 83
8Q
77
74
71
68
72
68
4.9
50
44
38
32
25
-
-
65
5.6
50
43
37
31
24
-
-
2500
67
62
4.8
62
56
50
43
37
31
24
60
5.3
60
54
48
42
35
29
23
62
57
4.7
57
57
57
51
44
38
32
53
5.3
53
53
53
47
41
34
28
57
55
4.7
55
55
55
48
42
36
29
51
5.4
51
51
51
44
38
32
25
72
67
4.9
48
42
36
30
24
-
-
65
5.4
47
41
35
29
23
-
-
2250
67
62
4.8
59
53
47
41
35
30
24
59
5.2
57
51
45
40
34
28
22
62
56
4.7
56
56
56
50
45
39
33
53
5.2
53
53
53
47
41
35
29
57
54
4.7
54
54
54
48
42
36
31
50
5.3
50
50
50
44
39
33
27
2000
72
66
4.9
45
39
34
29
23
-
-
64
5.3
44
39
33
28
22
-
-
2000
. 67
62
61
55
4.8
4.7
55
55
50
55
44
55
39
50
34
45
28
39
23
34
58 _
52
5.1
5.1
54
52
48
52
43
52
38
47
32
42
27
36
22
31
57
53
4.6
53
53
53
48
42
37
32
50
5.2
50
50
50
44
39
34
28
72
63
4.8
41
36
31
27
22
-
-
61
5.4
40
35
31
26
21
-
-
1750
67
58
4.7
51
46
41
36
32
27
22
56
5.1
49
44
39
35
30
25
21
62
53
4.6
53
53
51
47
42
37
32
50
5.2
50
50
48
43
39
34
29
57
51
4.6
51
51
49
44
40
35
30
47
5.2
47
47
46
41
36
32
27
72
60
4.8
37
33
29
25
21
-
-
58
5.4
36
32
28
24
20
-
-
1500
67
56
4.7
46
42
38
34
30
26
21
53
5.2
44
40
36
32
28
24
20
62
51
4.6
51
51
47
43
39
35
31
47
5.2
47
47
44
40
36
32
27
57
49
4.6
49
49
45
41
37
33
29
45
5.3
45
45
42
38
34
29
25
Air On
Evaporator
Coil
Temperature of Air on Condenser Coil
105°F
115°F
Total
Powe
Input
KW
Sensible Capacityl, MBH
Total
Cap.1
MBH
Powe
Input
KW
Sensible Capac'ty1, MBH
CFM
WB
F
Cap.1
MBH
Entering Dry Bulb, °F
Entering Dry Bulb, °F
86
83
80
77
74
71
68
86
83
80
77
74
71
68_
72
61
6.1
48
41
35
29
22
-
-
57
6.7
46
39
33
27
20
-
-
2500
67
55
5.9
55
52
46
39
33
27
20
50
6.6
50
50
43
37
31
24
18
62
49
5.9
49
49
49
42
36
30
23
44
6.5
44
44
44
38
31
25
19
57
47
5.9
47
47
47
40
34
28
21
42
6.5
42
42
42
36
30
23
17
72
61
6.0
45
39
33
28
22
-
-
57
6.6
43
38
32
26
20
-
-
2250
67
62
54
48
5.9
5.8
53
48
49
48
44
48
38
42
32
37
26
31
20
25
50
44
6.5
6.4
50
44
47
44
42
44
36
38
30
32
24
26
18
20
57
46
5.8
46
46
46
40
35
29
23
42
6.4
42
42
42
36
31
25
19
72
60
6.0
42
37
32
26
21
-
-
57
6.6
41
36
30
25
20
-
-
2000
67
54
5.8
52
47
41
36
31
25
20
50
6.5
50
45
40
34
29
24
18
62
48
5.7
48
48
48
43
37
32
27
44
6.4
44
44
44
38
33
28
22
57
46
5.8
46
46
46
41
35
30
25
42
6.3
42
42
42
37
32
26
21
72
57
6.0
38
34
29
24
19
-
-
53
6.5
37
32
27
23
18
-
-
1750
67
51
5.8
47
42
38
33
28
24
19
46
6.4
45
41
36
31
26
22
17
62
45
5.7
45
45
44
39
34
30
25
41
6.3
41
41
39
35
30
25
21
57
43
5.8
43
43
42
37
32
28
23
39
6.3
39
39
38
33
29
24
19
72
54
6.0
34
30
26
22
18
-
-
49
6.5
33
28
24
20
16
-
-
1500
67
48
5.8
42
38
34
30
26
22
18
43
6.4
40
36
32
28
24
20
16
62
43
5.7
43
43
39
35
31
27
23
38
6.3
38
38
35
31
27
23
19
57
41
5.8
41
41
38
34
30
26
21
37
6.2
37
37
34
30
26
22
18
1 These capacities are gross ratings. For net capacity, determine the KW of the supply air blower moto from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the
motor heat, and deduct this heat from the gross capacity of the unit
2 These ratings include the compressor and the condenser fan motors but not the supply ar blower motor. The total condenser fan motor power input is 0.36 KW. Refer to the Blower Performance
Table for the KW of the supply air blower motor.
NOMINAL RATING
6
ALL SENSIBLE CAPACITY
Unitary Products Group
530.18 -TG 1 Y
COOLING CAPACITIES - 6 TON (DCE / DCG072)
Air On
Evaporator
Coil
Temperature of Air on Condenser Coil
85°F
95°F
Total
Cap.1
MBH
Powe
Input
KW
Sensible Capac'ty1, MBH
Total
Cap.1
MBH
Powe
Input
KW
Sensible Capactyt, MBH
CFM
WB
°F
Entering
Dry Bulb, °F
Entering
Dry Bulb, °F
86
83
80
77
74
71
68
86
83
80
77
74
71
68
68
72
80
5.7
63
55
47
40
32
-
-
77
6.3
63
55
47
40
32
-
-
2700
67
62
80
70
5.7
5.5
76
70
68
70
60
70
53
62
45
55
37
47
30
39
77
71
6.3
6.3
75
71
68
71
60
71
53
63
45
56
37
48
30
40
25
27
57
68
5.6
68
68
68
60
52
45
37
71
6.3
71
71
71
63
56
48
40
27
72
82
5.7
60
53
46
38
31
-
-
76
6.3
60
53
46
39
31
-
-
2550
67
62
82
71
5.7
5.5
73
71
65
71
58
70
51
62
43
55
36
48
29
41
76
70
6.3
6.3
73
70
66
70
58
69
51
62
44
55
36
48
29
40
25
29
57
69
5.6
69
69
69
62
55
47
40
70
6.3
70
70
70
62
55
48
40
29
72
83
5.7
58
51
44
37
30
-
-
75
6.3
58
51
44
37
30
-
-
2400
_ 67.
62
83
73
5.7
5.5
70
73
63
73
56
70
49
63
42
56
35
49
28
42
_75
69
. 6.3
6.3
70
69
64
69
57
68
50
61
43
54
36
47
29
40
25
31
57
71
5.6
71
71
71
64
57
50
43
69
6.3
69
69
68
61
54
47
40
30
72
79
5.7
54
48
41
35
29
-
-
73
6.3
53
47
41
35
29
-
-
2100
67
79
5.7
65
59
53
47
40
34
28
73
6.3
65
59
52
46
40
34
28
24
62
69
5.5
69
69
66
60
54
47
41
67
6.3
67
66
63
57
51
45
38
29
57
67
5.6
67
67
67
61
54
48
42
67
6.3
67
66
63
57
51
45
39
29
72
74
5.6
50
44
39
34
28
-
-
71
6.3
49
43
38
33
27
-
-
1800
67
62
74
65
5.6
5.4
60
65
55
65
50
62
44
57
39
51
34
46
28
41
71
65
6.3
6.2
59
65
54
63
48
58
43
53
38
47
32
42
27
37
23
28
57
63
5,5
63
63
63
58
52
47
42
65
6.3
65
63
_ 58
53
47
42
37
Air On
Evaporator
Coil .
Temperature of Air on Condenser Coil
105°F
115°F
Total
Cap.1
MBH
Powe
Input
KW
Sensible Capac ty1, MBH
Total
Cap.1
MBH
Powe
Input
KW
Sensible Capac'ty1, MBH
CFM
WB
°F
Entering
Dry Bulb, °F
Entering
Dry Bulb, °F
86
83
80
77
74
71
68
86
83
80
77
74
71
68
72
76
7.1
61
53
45
38
30
-
-
75
7.9
59
51
43
36
28
-
_
-
2700
67
62
71
64
7.1
7.0
70
64
66
64
58
64
50
56
43
49
35
41
27
34
65
57
7.8
7.8
65
57
64
57
56
57
48
50
41
42
33
34
25
27
57
64
7.0
64
64
64
56
49
41
34
57
7.7
57
57
57
50
42
34
27
72
76
7.1
59
51
44
37
29
-
-
76
7.9
57
49
42
35
27
-
-
2550
67
62
71
64
7.1
7.0
69
64
64
64
56
64
49
56
42
49
34
42
27
35
66
58
7.9
7.8
66
58
61
58
54
58
47
51
40
43
32
36
25
29
57
64
7.0
64
64
64
56
49
42
34
58
7.7
58
58
58
50
43
36
29
72
75
7.1
56
49
43
36
29
-
-
76
8.0
55
48
41
34
27
-
-
2400
67
62
70
64
7.1
7.0
68
64
61
64
54
63
48
56
41
49
34
42
27
35
66
59
7.9
7.8
66
59
59
59
52
59
45
52
38
45
32
38
25
31
57
64
7.0
.64
64
63
56
49
42
35
59
7.7
59
59
58
51
44
37
30
72
73
7.1
52
45
39
33
27
-
-
73
7.9
50
44
37
31
25
-
-
2100
67
68
7.1
63
56
50
44
38
32
26
63
7.8
61
54
48
42
36
30
24
62
61
7.0
61
61
58
52
46
40
34
56
7.7
56
56
54
48
42
35
29
57
61
7.0
61
61
58
52
46
40
34
56
7.7
56
56
53
47
41
35
29
72
70
7.1
47
41
36
31
25
-
-
69
7.8
45
40
34
29
23
-
-
1800
67
62
65
59
7.0
7.0
57
59
51
58
46
54
41
48
35
43
30
38
25
32
60
53
7.8
7.7
55
53
49
53
44
49
39
44
33
39
28
33
23
28
57
59
6.9
59
58
53
48
43
37
32
53
7.6
53
53
49
44
38
33
27
I These capacities are gross ratings. For net capacity, determine the KW of the supply air dower motor from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the
motor heat, and deduct this heat from the gross capacity of the unit.
2 These ratings include the compressor and the condenser fan motors but not the supply air dower motor. The total condenser fan motor power input is 0,36 KW Refer to the Blower Performance
Tale for the KW of the supply air blower motor.
NOMINAL RATING
Unitary Products Group
ALL SENSIBLE CAPACITY
7
530.18 -TG 1 Y
• SUPPLY AIR BLOWER PERFORMANCE - DCG036 & 048 with Belt -Drive
DCG036 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS
MODEL
DCG
AIR FLOW
CFM
Available External Static Pressure - IWG*
0.20
0.30
0.40
0.50
0.60
0.70
0.80
RPM
Watts
, RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
036
1700
835
705
880
745
923
795
969
860
1013
970
-
-
-
-
1600
811
655
854
695
898
740
942
790
986
840
1029
900
-
-
1500
782
610
827
650
871
685
917
730
960
775
1003
825
1046
905
1400
-
-
798
595
844
640
889
680
932
720
975
765
1018
790
1300
-
-
-
-
816
590
862
635
907
675
951
715
995
750
1200
-
-
-
-
-
-
834
585
881
630
927
665
970
705
1100
-
-
-
-
-
-
809
550
855
590
900
625
942
665
1000
-
-
-
-
-
-
782
510
829
545
872
858
919
625
900
-
-
-
_ -
-
-
-
-
797
500
843
540
890
580
MODEL
DCG
AIR FLOW
CFM
Available External Static Pressure - IWG*
0.90
1.00
1.10
1.20
1.30
1.40
1.50
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
036
1700
-
-
,
-
-
-
-
-
-
--
1145
-
-
-
-
1600
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1500
-
-
-
-
-
-
-
-
-
-
-
-
-
-
1400
1055
875
-
-
-
-
-
-
--
900
-
-
-
-
1300
1036
780
1066
850
-
-
-
-
-
820
940
-
-
-
1200
1011
735
1047
765
1075
800
-
-
-
-
-
-
-
-
1100
987
690
1028
720
1060
750
1084
775
-
-
-
-
-
-
1000
963
655
1005
680
1040
695
1068
715
1089
735
-
-
-
-
900
936
615
980
645
1020
660
1050
670
1053
680
1090
690
-
-
NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0 95.
*INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN
GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS.
DCG048 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS
MODEL
DCG
AIR FLOW
CFM
Available External Static Pressure - IWG*
0.20
0.30
0.40
0.50
0.60
0.70
0.80
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
048
2000
843
860
880
925
919
1005
956
1065
993
1145
1030
1195
1067
,
1235
1900
817
775
854
850
893
920
930
995
970
1065
1008
1125
1046
1170
1800
790
700
828
760
867
840
906
905
944
980
985
1040
1025
1100
1700
-
-
802
670
840
745
881
815
920
900
961
970
1001
1030
1600
-
-
-
-
818
665
858
740
898
820
940
890
980
950
1500
-
-
-
-
-
-
842
695
882
755
922
835
962
895
1400
-
-
-
-
-
-
833
650
867
705
904
765
942
820
1300
-
-
-
-
-
-
-
-
858
665
893
725
932
785
1200
-
-
-
-
-
-
-
-
847
640
880
680
916
730
MODEL
DCG
AIR FLOW
CFM
Available External Static Pressure - IWG*
0.90
1.00
1.10
1.20
1.30
1.40
1.50
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Was
RPM
Watts
RPM
Watts
RPM
Watts
048
2000
1103
1270
-
-
-
-
-
-
-
-
-
-
-
-
1900
1085
1210
-
-
-
-
-
-
-
-
-
-
-
-
1800
1064
1145
1102
1180
-
-
-
-
-
-
-
-
-
-
1700
1040
1075
1081
1115
1121
1140
-
-
-
-
-
-
-
-
1600
1020
1005
1060
1050
1100
1085
-
-
-
-
-
-
-
-
1500
1003
945
1044
995
1086
1035
-
-
-
-
-
-
-
-
1400
982
880
1024
920
1067
965
1107
1000
-
-
-
-
-
-
1300
970
835
1010
870
1053
920
1099
960
-
-
-
-
-
-
1200
953
780
992
815
1034
855
1080
905
-
-
-
-
-
-
NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0 95.
*INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN
GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS.
8
Unitary Products Group
530.18 -TG 1 Y
. SUPPLY AIR BLOWER PERFORMANCE - DCG060 & 072 with Belt -Drive
DCG060 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS
MODEL
DCG
AIR FLOW
CFM
Available External Static Pressure - IWG*
0.20
0.30
0.40
0.50
0.60
0.70
0.80
RPM
, Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
060
2500
1059
1560
1077
1590
1095
1630
1114
_Watts
1650
1134
1660
1158
1685
1181
1720
2400
1032
1405
1054
1470
1074
1525
1094
1560
1116
1595
1140
1620
1167
1640
2300
1005
1260
1024
1275
1049
1370
1069
1440
1090
1475
1116
1505
1142
1535
2200
980
1160
1002
1170
1022
1190
1044
1250
1066
1350
1090
1410
1117
1440
2100
930
1060
957
1070
983
1080
1010
1100
1039
1160
1064
1260
1092
1340
2000
877
950
908
975
941
1000
976
1020
1009
1050
1040
1100
1070
1225
1900
-
-
-
-
894
885
940
940
980
980
1014
1020
1047
1095
1800
-
-
-
-
855
815
903
860
950
905
988
940
1022
970
1700
-
-
-
--
1103
-
884
815
925
850
964
880
1001
910
1600
-
-
-
-
-
-
864
770
908
805
948
835
987
870
1500
-
-
-
-
_ -
-
-
-
882
_ 740
926
780
_ 965
830
MODEL
DCG
AIR FLOW
CFM
Available External Static Pressure - IWG*
0.90
1.00
1.10
1.20
1.30
1.40
1.50
RPM
Watts
RPM
Watts
RPM
Waits
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
060
2500
-
-
-
-
-
-
-
_Watts
-
-
-
-
-
-
-
2400
1193
1665
-
--
1157
-
-
-
-
-
-
-
-
-
2300
1170
1580
1202
1620
-
-
-
-
-
--
1190
-
-
-
2200
1148
1480
1180
1530
-
-
-
-
-
--
1135
-
-
-
2100
1121
1385
1155
1425
1190
1475
-
-
-
-
-
-
-
-
2000
1100
1285
1133
1340
1169
1385
1205
1445
-
-
-
-
-
-
1900
1079
1180
1110
1240
1143
1280
1178
1330
1222
1375
-
-
-
-
1800
1058
1060
1090
1135
1122
1190
1158
1240
1196
1295
-
-
-
-
1700
1035
960
1071
1030
1103
1100
1134
1140
1164
1175
1197
1205
-
-
1600
1020
900
1056
965
1088
1035
1118
1065
1145
1105
1170
1130
1198
1150
1500
1004
860
1038
880
1070
925
1101
980
1130
1045
1158
1075
1184
1110
NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0 95.
*INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1' FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN
GAS I ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS.
DCG072 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS
MODEL
DCG
AIR FLOW
CFM
Available External Static Pressure - IWG*
0.20
0.30
0.40
0.50
0.60
0.70
0.80
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
072
3200
1150
2325
1182
2425
1212
2525
-
-
-
-
-
-
-
-
3000
1100
2010
1129
2090
1157
2150
1185
2225
1215
2290
1242
2360
-
-
2800
1045
1700
1074
1780
1102
1850
1131
1940
1160
2025
1190
2075
1217
2130
2600
985
1425
1015
1475
1045
1540
1075
1630
1103
1715
1135
1760
1163
1825
2400
930
1240
958
1300
990
1350
1020
1400
1051
1430
1081
1490
1111
1600
2200
-
-
905
1070
933
1160
965
1210
997
1250
1028
1285
1060
1325
2000
-
-
-
--
1109
-
919
1025
950
1100
982
1130
1014
1160
1800
-
-
-
-
--
1060
-
-
909
925
939
1005
968
1030
MODEL
DCG
AIR FLOW
CFM
Available External Static Pressure - IWG'
0.90
1.00
1.10
1.20
1.30
1.40
1.50
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
RPM
Watts
072
3200
-
-
-
-
3000
-
-
-
-
-
-
-
-
-
-
-
-
-
-
2800
1245
2190
-
-
-
-
-
-
-
-
-
-
-
-
2600
1193
1920
1222
1990
1250
2060
-
-
-
-
-
-
-
-
2400
1142
1675
1173
1730
1205
1800
1234
1885
-
-
-
-
-
-
2200
1090
1380
1124
1450
1155
1550
1186
1640
1217
1710
1249
1775
-
-
2000
1045
1175
1077
1200
1109
1275
1140
1360
1170
1460
1205
1545
1235
1600
1800
998
1050
1028
1060
1058
1060
1087
1075
1118
1150
1148
1250
1176
1360
NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0 95.
INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN
GAS / ELECTRIC UNITS 1MTH SIDE DUCT AIRFLOWS.
Unitary Products Group
9
530.18 -TG 1 Y
SUPPLY AIR BLOWER PERFORMANCE - DCG036, 048, 060, 072 with Direct -Drive
GAS HEAT 230/460/575 VOLTS - Side Duct Applications
MODEL
DCG
MOTOR
SPEED0.20
Available External Static Pressure - IWG*
0.30
0.40
0.50
0.60
0.70
0.80
0.90
1.00
CFM
Watts
CFM,
Watts
CFM
Watts
CFM
Watts,
CFM
Watts
CFM
Watts
CFM
Watts,
CFM
Watts
CFM
Watts
HI
-
-
-
-
1699
825
1650
785
1570
755
1430
725
1360
700
1280
680
1180
655
036
MED
1684
800
1631
780
1582
750
1524
720
1410
690
1324
650
1260
630
1185
610
1100
590
LOW
1487
710
1464
690
1421
670
1367
650
1315
620
1246
605
1185
590
1110
570
1020
545
HI
1996
960
1933
936
1868
910
1795
880
1722
845
1635
820
1544
790
1419
765
1300
740
048
MED
1804
838
1765
810
1714
785
1650
765
1589
735
1508
705
1407
675
1306
645
1195
625
LOW
1681
760
1640
738
1604
715
1541
695
1490
670
1416
645
1337
620
1230
595
1120
575
HI
2400
1155
2338
1125
2274
1095
2167
1045
2096
1010
1990
980
1887
945
1771
905
1629
855
060
MED
2290
1105
2214
1065
2145
1030
2071
990
1990
950
1911
920
1828
885
1724
835
1604
798
LOW
2150
1020
2100
990
2029
950
1965
910
1905
880
1816
838
1724
800
1644
770
1531
710
072
HI
2461
1480
2402
1440
2361
1395
2260
1350
2178
1305
2101
1260
2000
1205
1914
1155
1830
1110
*INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1' FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES
ON APPLICATIONS OTHER THAN GAS/ ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS.
NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95.
FACTORY -INSTALLED OPTIONS
ECONOMIZERS: Units equipped with a factory -installed economizer
option have dampers that are positioned by a spring return, fully
modulating damper actuator and are capable of introducing up to 100%
outdoor air. As the outdoor air intake dampers open, the return air
dampers close. The changeover from mechanical refrigeration to
economizer operation is determined by a single input electronic enthalpy
control or by a dual input electronic enthalpy control. Simultaneous scroll
compressor and economizer operation is also possible.
The single enthalpy system contains a sensor that monitors the outdoor
air which automatically operates the damper actuator allowing the
dampers to open or close.
The dual enthalpy system contains a second sensor that monitors both
the temperature and the humidity of the return air in addition to the
outdoor air sensor described for a single enthalpy system. The logic
module compares the inputs from both sensors and switches to
economizer operation whenever the outdoor air is cooler than the
return air for maximum efficiency of the economizer system.
The economizer is completely wired and installed at the factory. Only
the outdoor air hood, including its filters, need be assembled and
installed in the field.
BELT DRIVE BLOWERS: Adjustable belt -drive blowers providing
maximum flexibility to handle many airflow requirements, are available
on all models.
FIELD -INSTALLED ACCESSORIES
SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes
a slide -in / plug-in damper assembly with fully modulating spring return
motor actuator capable of introducing up to 100% outdoor air, one
outdoor air electronic enthalpy sensor and a rain hood with filters. The
rain hood is painted to match the basic unit and must be
field -assembled before installation. Economizer dampers are 2% low
leakage type.
DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes
the same damper system and rain hood with filters as described for a
single enthalpy economizer except this accessory contains two
enthalpy sensors. It uses a differential enthalpy control that compares
the outdoor air versus the return air. The logic module then optimizes
the economizer operation for additional savings over the single input
economizer.
MOTORIZED AIR DAMPER - Includes a slid-in/plug-in damper
assembly with a rainhood and filters. The outdoor air dampers
open when the indoor fan motor is energized. The damper is
capable of providing 0% through 100% of outdoor return air
opening.
MANUAL OUTDOOR DAMPER - Provides 0% through 35%
or 0% through 100% of return air opening (field adjustable).
Designed for duct mounted side or bottom supply/return
applications. Includes rain hood assembly and filter.
ELECTRIC HEATERS - Include nickel chromium elements, a terminal
block, fuses (where required by UL), all the necessary connectors and
hardware. All heaters utilize single point power supply hookup.
Capacities from 5 KW thru 30 KW heating are available.
FUSE BLOCK KITS - These kits have a fuse box with a fuse block and
fuses. They're available for all 460-3-60 volt heaters and 208/230-3-60
volt heaters 7 KW and smaller.
OUTDOOR THERMOSTAT- A 24 -volt thermostat providing two stages
of control for units equipped with electric heat accessories.
ROOF CURB -This 14" high full perimeter roof curb is shipped knocked
down for field assembly and contains duct supports that can easily be
shifted for the desired unit duct arrangement. No insulated deck is
required because the unit underside is insulated.
START ASSIST KIT - Provides increased starting torque for single
phase units in areas with low voltage conditions. It contains a 12.5 OHM
PTCR temperature resistor with a support clip and hardware for
mounting.
LOW AMBIENT KIT -A low ambient controller maintains stable system
operation by reducing the speed of the condenser fan motor when the
outdoor temperature is between 45 and 0°F.
ANTI -RECYCLE TIMER- A timer to prevent the units scroll compressor
from short cycling. It assures a 5 -minute off -time between compressor
cycles.
PROPANE CONVERSION KIT - Converts a gas-fired heater from
natural gas to propane. It contains main burner orifices, a pilot orifice
and a regulator spring.
LOW NOx KIT (natural gas furnaces only) - Contains five stainless
steel expanded metal sheets for mounting into the heat exchanger
tubes to meet the California low nitrous oxide emission requirements.
HIGH ALTITUDE CONVERSION (NATURAL AND PROPANE) -
Provides orifices for proper furnace operation at altitudes up to 6000
feet. For propane applications, the propane conversion kit will also be
required.
GAS PIPING - This kit contains 1/2" pipe nipples, fittings and gas cock
(including panel access gaskets) required for bottom gas supply
connection with external shut-off.
OUTDOOR COIL GUARD - Consists of grille -type sections for
installation over the outdoor coil to protect it from damage.
WALL THERMOSTAT - The units are designed to operate with 24 -volt
electronic and electro -mechanical thermostats. All units can operate
with single stage heat / single stage cool thermostats - with or without
the economizer.
10 Unitary Products Group
STATIC RESISTANCES
EXTERNAL STATIC PRESSURE DROP
530.18 -TG 1 Y
DESCRIPTION
RESISTANCE, IWG
CFM
1000
1200 _
1400
1600
1800
2000
2200
2400
2600
2800
3000
Economizer• 3
0.07
0.08
0.09
0.11
0.13
0.15
0.17
0.20
0.23
0.26
0.30
Electric Heaters
5 - 15 KW
0.04
0.05
0.06
0.07
0.08
0.10
0.12
0.14
0.16
0.19
0.22
20 - 30 KW
0.06
0.07
0.08
0.09
0.11
0.13
0.15
0.17
0.20
0.23
0.26
Bottom Duct Connections
0.06
0.07
0.08
0.09
0.10
0.11
0.12
0.14
0.16
0.19
0.22
Cooling Onlv2
0.08
0.10
0.12
0.14
0.16
_ 0.18
0.20
0.23 _
0.26
0.29
0.32
'Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table.
'Add these resistance values to the available static resistance in the respective Blower Performance Table.
'The presvaet or the economizer is greater 6100%outdoor sir than far 100% ream &. lftre resistsnce oftlte return eiduct system® lessthan 025 Pf , the uritwi delver less CFM during tdecawnveroperator.
_Ralfi-
*Al motors have solid bases and are inherently protected. These motors; can be selected to operate into their service factor because they are located In the moving etr, upstream of any heating device.
ELECTRICAL DATA - Basic Units with Direct -Drive
MODEL
DCE
DCG
BLOWER
MOTOR'
ADJUSTABLE
MOTOR PULLEY
FIXED
BLOWER PULLEY
BELT
MODEL
RANGE
MAX.
HACR
BREAKER
SIZE,
AMPS
MIN.
MAX.
RLA
PITCH
PITCH
187
PITCH
18.0
105.0
(RPM)
HP
RPM
FRAME
SERVICE
DIA.
BORE
DIA.
BORE
LENGTH
DESIG-
1.3
0.8
4.4
2.2
20.0
10.8
30
15
SIZE
FACTOR
/in)
(in.)
(in.)
(in.)
(in.)
NATION
DCE / DCG 036
790 - 1120
11/2
1725
56
1.15
2.4 - 3.4
7/8
5.7
1
37.3
A36
DCE / DCG 048
790 - 1120
11/2
1725
56
1.15
2.4 - 3.4
7/8
5.7
1
37.3
A36
DCE / DCG 060
850 - 1220
11/2
1725
56
1.15
2.4 - 3.4
7/8
5.2
1
37.3
A36
DCE / DCG 072
900 - 1250
11/2
1725
_ 56
1.15
2.8 - 3.8
7/8
5.2
1
37.3
A36
*Al motors have solid bases and are inherently protected. These motors; can be selected to operate into their service factor because they are located In the moving etr, upstream of any heating device.
ELECTRICAL DATA - Basic Units with Direct -Drive
MODEL
DCE
DCG
POWER
SUPPLY
VOLTAGE
LIMITATIONS
(SEE NOTE 1)
SCROLL
COMPRESSOR
COND.
FAN
MOTOR
FLA,
SUPPLY
AIR
BLOWER
MOTOR,
FLA
MINIMUM
CIRCUIT
AMPACITY
MAX.
FUSE
SIZE,
(SEE NOTE 2)
AMPS
MAX.
HACR
BREAKER
SIZE,
AMPS
MIN.
MAX.
RLA
LRA
208/230-1-60
187
253
18.0
105.0
1.3
4.4
28.2
45
45
036
208/230-3-60
460-3-60
187
414
253
504
11.4
6.2
90.0
45.0
1.3
0.8
4.4
2.2
20.0
10.8
30
15
30
15
575-3-60
518
630
5.0
36.0
0.8
2.2
9.3
15
-
208/230-1-60
187
253
24.4
140.0
1.3
5.0
36.8
60
60
048
208/230-3-60
460-3-60
187
414
253
504
14.1
7.1
105.0
55.0
1.3
0.8
5.0
2.2
23.9
11.9
35
15
35
15
575-3-60
518
630
5.6
44.0
0.8
2.2
10.1
15
-
208/230-1-60
187
253
28.9
165.0
1.3
6.6
44.0
70
70
060
208/230-3-60
460-3-60
187
414
253
504
16.0
8.0
125.0
67.0
1.3
0.8
6.6
3.3
27.9
14.1
40
20
40
20
575-3-60
518
630
6.4
50.0
0.8
3.3
12.1
15
-
208/230-3-60
187
253
20.3
146.0
1.3
6.8
33.5
50
50
072
460-3-60
414
504
10.2
73.0
0.8
3.6
17.2
25
25
575-3-60
518
630
8.2
58.4
0.8
3.6
14.7 _
20
-
NOTES: 1. Utilization Range "A" in accordance with ARI Standard 110.
2. Dual element, time delay type.
ELECTRICAL DATA - Basic Units with Belt -Drive
MODEL
DCE
DCG
POWER
SUPPLY
VOLTAGE
LIMITATIONS
(SEE NOTE 1)
SCROLL
COMPRESSOR
COND.
FAN
MOTOR
FLA,
SUPPLY
AIR
BLOWER
MOTOR,
FLA
MINIMUM
CIRCUIT
AMPACITY
MAX.
FUSE
SIZE,
(SEE NOTE 2)
AMPS
MAX.
HACR
BREAKER
SIZE,
AMPS
MIN.
MAX.
RLA
LRA
208/230-1-60
187
253
18.0
105.0
1.3
5.3
,
29.1
45
45
036
208/230-3-60
460-3-60
187
414
253
504
11.4
6.2
90.0
45.0
1.3
0.8
5.3
3.1
20.9
11.7
30
15
30
15
575-3-60
518
630
5.0
36.0
0.8
3.1
10.2
15
-
208/230-1-60
187
253
24.4
140.0
1.3
8.6
40.4
60
60
048
208/230-3-60
460-3-60
187
414
253
504
14.1
7.1
105.0
55.0
1.3
0.8
5.2
2.6
24.1
12.3
35
15
35
15
575-3-60
518
630
5.6
44.0
0.8
2.0
9.9
15
-
208/230-1-60
187
253
28.9
165.0
1.3
8.6
46.0
70
70
060
208/230-3-60
460-3-60
187
414
253
504
16.0
8.0
125.0
67.0
1.3
0.8
6.0
3.0
27.3
13.8
40
20
40
20
575-3-60
518
630
6.4
50.0
0.8
2.4
11.2
15
-
208/230-3-60
187
253
20.3
146.0
1.3
7.3
34.0
50
50
072
460-3-60
414
504
10.2
73.0
0.8
3.7
17.3
25
25
575-3-60
518
630
8.2
58.4
0.8
2.8
13.9
20
-
NOTES: 1. Rated in accordance with ARI Standard 110, utilization range "A'. 2. Dual element, time delay type.
Unitary Products Group
11
530.18-TG'I Y
ELECTRICAL DATA - Cooling / Electric Heating (DCE036 & 048) with Direct -Drive
MODEL
DCE
POWER
SUPPLY
HEATER
ACCESSORY
MODEL
NUMBER
SUPPLY
AIR
BLOWER
MOTOR
FLA
ELECTRIC HEATERS
MINIMUM
CIRCUIT
AM PACITY
MAX
FUS
SIZE
AMPS
MAX.
SIZE
HACK 2
BREAKER
AMPS
KW
STAGES
TOTAL
AMPS
2CE04500506
4.0
1
19.1
29.4
45
45
2CE04500706
5.6
1
27.1
39.4
45
45
208-1-60
2CE04501006
4.4
8.0
1
38.3
53.3
60
60
2CE04501506
11.9
2
57.4
77.3
80
80
2CE04502006
15.9
2
76.6
101.2
110
110
2CE04500506
5.3
1
22.1
33.1
45
45
2CE04500706
7.5
1
31.3
44.6
45
45
230-1-60
2CE04501006
4.4
10.6
1
44.2
60.7
70
70
2CE04501506
15.9
2
66.3
88.3
90
90
2CE04502006
21.2
2
88.3
115.9
125
125
2CE04500525*
4.0
1
11.0
20.0
30
--I CT W WW
0CA CT 00
2CE04500725*
5.6
1
15.6
25.0
30
036
208-3-60
2CE04501025
2CE04501525
4.4
8.0
11.9
1
2
22.1
33.1
33.1
46.9
35
50
2CE04502025
15.9
2
44.2
60.7
70
2CE04500525*
5.3
1
12.7
21.4
30
30
2CE04500725*
7.5
1
18.0
28.1
30
30
230-3-60
2CE04501025
4.4
10.6
1
25.5
37.4
40
40
2CE04501525
15.9
2
38.2
53.3
60
60
2CE04502025
21.2
2
51.0
69.2
70
70
2CE04500746*
6.8
1
8.2
13.0
15
15
2CE04501046*
10.1
1
12.1
17.9
20
20
460-3-602CE04501546*
2'2
13.6
1
16.4
23.2
25
25
2CE04502046*
19.5
2
23.5
32.1
35
35
2CE04501058
10.6
1
10.2
15.5
20
-
575-3-60
2CE04501558
2.2
15.9
1
15.3
21.9
25
-
2CE04502058
21.2
2
20.4
28.2
30
-
2CE04500506
4.0
1
19.1
36.8
60
60
2CE04500706
5.6
1
27.1
40.1
60
60
208-1-60
2CE04501006
5.0
8.0
1
38.3
54.1
60
60
2CE04501506
11.9
2
57.4
78.0
80
80
2CE04502006
15.9
2
76.6
101.9
110
110
2CE04500506
5.3
1
22.1
36.8
60
60
2CE04500706
7.5
1
31.3
45.3
60
60
230-1-60
2CE04501006
5.0
10.6
1
44.2
61.5
70
70
2CE04501506
15.9
2
66.3
89.1
90
90
2CE04502006
21.2
2
88.3
116.7
125
125
2CE04500525*
4.0
1
11.0
23.9
35
35
2CE04500725*
5.6
1
15.6
25.8
35
35
048
208-3-60
2CE04501025
2CE04501525
5.0
8.0
11.9
1
2
22.1
33.1
33.9
47.7
35
50
35
50
2CE04502025
15.9
2
44.2
61.5
70
70
2CE04500525*
5.3
1
12.7
23.9
35
35
2CE04500725*
7.5
1
18.0
28.8
35
35
230-3-60
2CE04501025
5.0
10.6
1
25.5
38.1
40
40
2CE04501525
15.9
2
38.2
54.1
60
60
2CE04502025
21.2
2
51.0
70.0
70
70
2CE04500746*
6.8
1
8.2
13.0
15
15
460-3-602.2
2CE04501046*
2C
2'2
10.1
13.6
1
1
12.1
16.4
17.9
23.2
20
25
20
25
2CE04502046*
19.5
2
23.5
32.1
35
35
2CE04501058
10.6
1
10.2
15.5
20
-
575-3-60
2CE04501558
2.2
15.9
1
15.3
21.9
25
-
2CE04502058
21.2
2
20.4
28.2
30
-
Dual element, lime delay type
Standard circuit breakers may be used in Canada and on applications
over 60 amps where the heaters are separately fused.
• These electric heaters DO NOT include a fuse box. If a fuse box is
required to meet a local code ((eg., Chicago), the following fuse
block accessories are available for field installation.
12
Electric Heat
Correction
Factors
Nominal Voltage
Voltage
KW Cap
Multipier
1.00
0.92
0.92
0.92
208
208
240
230
480
460
600
575
Fuse Block
2FB04700425
208/240 Volts
460 Volts
2FB04700546
Unitary Products Group
530.18 -TG 1 Y
ELECTRICAL DATA - Cooling / Electric Heating (DCE060 & 072) with Direct -Drive
MODEL
DCE
POWER
SUPPLY
HEATER
ACCESSORY
MODEL
NUMBER
SUPPLY
AIR
BLOWER
MOTOR
FLA
ELECTRIC HEATERS
MINIMUM
CIRCUIT
AMPACITY
FUAX.
SIZE
AMPS
MAX.
SIZE
HACR
BREAKER
AMPS
KW
STAGES
TOTAL
AMPS
2CE04500506
4.0
1
19.1
44.0
70
70
2CE04500706
5.6
1
27.1
44.0
70
70
208-1-60
2CE04501006
2CE04501506
6 6
8.0
11.9
1
2
38.3
57.4
56.1
80.0
70
90
70
90
2CE04502006
15.9
2
76.6
103.9
110
110
2CE04503006
22.2
2
106.9
141.9
150
150
2CE04500506
5.3
1
22.1
44.0
70
70
2CE04500706
7.5
1
31.3
47.3
70
70
230-1-60
2CE04501006
2CE04501506
6 6
10.6
15.9
1
2
44.2
66.3
63.5
91.1
70
100
70
100
2CE04502006
21.2
2
88.3
118.7
125
125
2CE04503006
29.6
2
123.3
162.4
175
175
2CE04500525*
4.0
1
11.0
27.9
40
40
2CE04500725*
5.6
1
15.6
27.9
40
40
208-3-60
2CE04501025
6 6
8.0
1
22.1
35.9
40
40
060
2CE04501525
2CE04502025
11.9
15.9
2
2
33.1
44.2
49.7
63.5
50
70
50
70
2CE04503025
22.2
2
61.7
85.4
90
90
2CE04500525*
5.3
1
12.7
27.9
40
40
2CE04500725*
7.5
1
18.0
30.8
40
40
230-3-60
2CE04501025
2CE04501525
6 6
10.6
15.9
1
2
25.5
38.2
40.1
56.1
45
60
45
60
2CE04502025
21.2
2
51.0
72.0
80
80
2CE04503025
29.6
2
71.2
97.3
100
100
2CE04500746*
6.8
1
8.2
14.3
20
20
2CE04501046*
10.1
1
12.1
19.3
20
20
460-3-60
2CE04501546*
3.3
13.6
1
16.4
24.6
25
25
2CE04502046*
19.5
2
23.5
33.4
35
35
2CE04503046*
28.8
2
34.6
47.4
50
50
2CE04501058
10.6
1
10.2
16.9
20
-
575-3-60
2CE04501558
2CE04502058
3 3
15.9
21.2
1
2
15.3
20.4
23.2
29.6
25
30
-
-
2CE04503058
30.4
2
29.3
40.7
45
-
2CE04500525*
4.0
1
11.0
33.5
50
oo0000
(C) U) U) U) N- C)
2CE04500725*
5.6
1
15.6
33.5
50
208-3-60
2CE04501025
2CE04501525
6 8
8.0
11.9
1
2
22.1
33.1
36.1
49.9
50
50
2CE04502025
15.9
2
44.2
63.7
70
2CE04503025
22.2
2
61.7
85.6
90
2CE04500525*
5.3
1
12.7
33.5
50
50
2CE04500725*
7.5
1
18.0
33.5
50
50
230-3-60
2CE04501025
2CE04501525
6 8
10.6
15.9
1
2
25.5
38.2
40.4
56.3
50
60
50
60
072
2CE04502025
21.2
2
51.0
72.2
80
80
2CE04503025
29.6
2
71.2
97.5
100
100
2CE04500746*
6.8
1
8.2
17.2
v) U) U) U) 0
N N N CO U)
25
2CE04501046*
10.1
1
12.1
19.7
25
460-3-60
2CE04501546*
3.6
13.6
1
16.4
24.9
25
2CE04502046*
19.5
2
23.5
33.8
35
2CE04503046*
28.8
2
34.6
47.8
50
2CE04501058
10.6
1
10.2
17.2
20
-
575-3-60
2CE04501558
2CE04502058
3 6
15.9
21.2
1
2
15.3
20.4
23.6
30.0
25
30
-
-
2CE04503058
30.4
2
29.3
41.1
45
-
Dual element, time delay type
Standard arch breakers may be used in Canada and on applications
over 60 amps where the heaters are separately fused.
• These Necbic heaters DO NOT include a fuse box. If a fuse box is
required to meet a local code ((eg., Chicago), the following fuse
block accessories are available for field installation.
Unitary Products Group
Electric Heat
Correction
Factors
Nominal Voltage
Voltage
KW Cap
Multipier
1.00
0.92
0.92
208
208
240
230
480
460
600
575
0.92
Fuse Block
2FB04700425
2FB04700546
208240 Volts
460 Volts
13
530.18 -TG 1 Y
tLtC: I KILAL UAIA - Cooling / Electric Heating (DCE036 & 048) with Belt -Drive
MODEL
DCE
POWER
SUPPLY
HEATER
ACCESSORY
MODEL
NUMBER
SUPPLY
AIR
BLOWER
MOTOR
FLA
ELECTRIC HEATERS
MINIMUM
CIRCUIT
AMPACITY
MAX
FUS
SIZE
AMPS
MAX.
SIZE
HACR 2
BREAKER
AMPS
KW
STAGES
TOTAL
AMPS
2CE04500506
4.0
1
19.1
30.5
45
45
2CE04500706
5.6
1
27.1
40.5
45
45
208-1-60
2CE04501006
5.3
8.0
1
38.3
54.5
60
60
2CE04501506
11.9
2
57.4
78.4
80
80
2CE04502006
15.9
2
76.6
102.3
110
110
2CE04500506
5.3
1
22.1
34.2
45
45
2CE04500706
7.5
1
31.2
45.7
50
50
230-1-60
2CE04501006
5.3
10.6
1
44.2
61.8
70
70
2CE04501506
15.9
2
66.3
89.4
90
90
2CE04502006
21.2
2
88.3
117.0
125
125
2CE04500525*
4.0
1
11.0
20.9
30
30
2CE04500725*
5.6
1
15.6
26.2
30
30
036
208-3-60
2CE04501025
2CE04501525
5.3
8.0
11.9
1
2
22.1
33.1
34.2
48.1
35
50
35
50
2CE04502025
15.9
2
44.2
61.9
70
70
2CE04500525*
5.3
1
12.7
22.6
30
30
2CE04500725*
7.5
1
18.0
29.2
30
30
230-3-60
2CE04501025
5.3
10.6
1
25.5
38.5
40
40
2CE04501525
15.9
2
38.2
54.4
60
60
2CE04502025
21.2
2
51.0
70.4
80
80
2CE04500746*
6.8
1
8.2
14.1
15
15
460-3-60
2CE04501046*
2C E04501546*
3 1
10.1
13.6
1
1
12.1
16.4
19.1
24.3
20
25
20
25
2CE04502046*
19.5
2
23.5
33.2
35
35
2CE04501058
10.6
1
10.2
16.6
20
-
575-3-60
2CE04501558
3.1
15.9
1
15.3
23.0
25
-
2CE04502058
21.2
2
20.4
29.4
30
-
2CE04500506
4.0
1
19.1
40.4
60
60
2CE04500706
5.6
1
27.1
44.6
60
60
208-1-60
2CE04501006
8.6
8.0
1
38.3
58.6
60
60
2CE04501506
11.9
2
57.4
82.5
90
90
2CE04502006
15.9
2
76.6
106.4
110
110
2CE04500506
5.3
1
22.1
40.4
60
60
2CE04500706
7.5
1
31.3
49.8
60
60
230-1-60
2CE04501006
8.6
10.6
1
44.2
66.0
70
70
2CE04501506
15.9
2
66.3
93.6
100
100
2CE04502006
21.2
2
88.3
121.2
125
125
2CE04500525*
4.0
1
11.0
24.1
35
35
2CE04500725*
5.6
1
15.6
26.0
35
35
048
208-3-60
2CE04501025
2CE04501525
5.2
8.0
11.9
1
2
22.1
33.1
34.1
47.9
35
50
35
50
2CE04502025
15.9
2
44.2
61.7
70
70
2CE04500525*
5.3
1
12.7
24.1
OD O) A CO CO
OOO U) U)
35
2CE04500725*
7.5
1
18.0
29.1
35
230-3-60
2CE04501025
5.2
10.6
1
25.5
38.4
40
2CE04501525
15.9
2
38.2
54.3
60
2CE04502025
21.2
2
51.0
70.2
80
2CE04500746*
6.8
1
8.2
13.5
15
15
460-3-60
2CE04501046*
2CE04501546*
2 6
10.1
13.6
1
1
12.1
16.4
18.4
23.7
20
25
20
25
2CE04502046*
19.5
2
23.5
32.6
35
35
2CE04501058
10.6
1
10.2
15.2
20
-
575-3-60
2CE04501558
2.0
15.9
1
15.3
21.6
25
-
2CE04502058
21.2
2
20.4
28.0
30 .
-
Dual element, time delay type
Standard circuit breakers may be used in Canada and on applications
over 60 amps where the heaters are separately fused.
• These electric heaters DO NOT include a fuse box. It a hue boa is
required to meet a local code ((eg., Chicago), the following fuse
dock accessories are evadable for field installation.
14
Electric Heat
Correction
Factors
Nominal Voltage
Voltage
KW Cap
Multipier
1.00
0.92
0.92
0.92
208
208
240
230
480
460
600
575
Fuse Block
2FB04700425
208/240 Volts
2FB04700546
460 Volts
Unitary Products Group
530.18 -TG 1 Y
ELECTRICAL DATA - Cooling / Electric Heating (DCE060 & 072) with Belt -Drive
MODEL
DCE
POWER
SUPPLY
HER
ACCESSORY
MODEL
NUMBER
SUPPLY
AIR
BLOWER
MOTOR
FLA
ELECTRIC HEATERS
MINIMUM
CIRCUIT
AMPACITY
MAX.U
SIZE
AMPS
MAX.
SIZE
HACR
BREAKER
AMPS
KW
STAGES
TOTAL
AMPS
2CE04500506
4.0
1
19.1
46.0
70
70
2CE04500706
5.6
1
27.1
46.0
70
70
208-1-60
2CE04501006
2CE04501506
8 6
8.0
11.9
1
2
38.3
57.4
58.6
82.5
70
90
70
90
2CE04502006
15.9
2
76.6
106.4
110
110
2CE04503006
22.2
2
106.9
144.4
150
150
2CE04500506
5.3
1
22.1
46.0
70
70
2CE04500706
7.5
1
31.3
49.8
70
70
230-1-60
2CE04501006
2CE04501506
8 6
10.6
15.9
1
2
44.2
66.3
66.0
93.6
70
100
70
100
2CE04502006
21.2
2
88.3
121.2
125
125
2CE04503006
29.6
2
123.3
164.9
175
175
2CE04500525*
4.0
1
11.0
27.3
40
40
2CE04500725*
5.6
1
15.6
27.3
40
40
208-3-60
2CE04501025
2CE04501525
6 0
8.0
11.9
1
2
22.1
33.1
35.1
48.9
40
50
40
50
060
2CE04502025
15.9
2
44.2
62.7
70
70
2CE04503025
22.2
2
61.7
84.6
90
90
2CE04500525*
5.3
1
12.7
27.3
40
40
2CE04500725*
7.5
1
18.0
30.1
40
40
230-3-60
2CE04501025
2CE04501525
6 0
10.6
15.9
1
2
25.5
38.2
39.4
55.3
40
60
40
60
2CE04502025
21.2
2
51.0
71.2
80
80
2CE04503025
29.6
2
71.2
96.5
100
100
2CE04500746*
6.8
1
8.2
14.0
20
O O in in 0
N N N M U)
2C E04501046*
10.1
1
12.1
18.9
20
460-3-60
2CE04501546*
3.0
13.6
1
16.4
24.2
25
2CE04502046*
19.5
2
23.5
33.1
35
2CE04503046*
28.8
2
34.6
47.1
50
2CE04501058
10.6
1
10.2
15.7
20
-
575-3-60
2CE04501558
2CE04502058
2 4
15.9
21.2
1
2
15.3
20.4
22.1
28.5
25
30
-
-
2CE04503058
30.4
2
29.3
39.6
40
-
2CE04500525*
4.0
1
11.0
34.0
50
50
2CE04500725*
5.6
1
15.6
34.0
50
50
208-3-60
2CE04501025
2CE04501525
7. 3
8.0
11.9
1
2
22.1
33.1
36.7
50.6
50
60
50
60
2CE04502025
15.9
2
44.2
64.4
70
70
2CE04503025
22.2
2
61.7
86.3
90
90
2CE04500525*
5.3
1
12.7
34.0
50
50
2CE04500725*
7.5
1
18.0
34.0
50
50
2CE04501025
10.6
1
25.5
41.0
50
50
230-3-60
2CE04501525
7'3
15.9
2
38.2
56.9
60
60
072
2CE04502025
21.2
2
51.0
72.9
80
80
2CE04503025
29.6
2
71.2
98.1
100
100
2CE04500746*
6.8
1
8.2
17.3
25
25
2CE04501046*
10.1
1
12.1
19.8
25
25
460-3-60
2CE04501546*
3.7
13.6
1
16.4
25.1
30
30
2CE04502046*
19.5
2
23.5
33.9
35
35
2CE04503046*
28.8
2
34.6
47.9
50
50
2CE04501058
10.6
1
10.2
16.2
20
-
575-3-60
2CE04501558
2CE04502058
2 8
15.9
21.2
1
2
15.3
20.4
22.6
29.0
25
30
-
-
2CE04503058
30.4
2
29.3
40.1
45
-
Dual element, time delay type
' Standard draft breakers may be used in Canada and on applications
over 60 apps where the heaters are separately fused.
These decbic heaters DO NOT include a fuse box. If a fuse box is
required to meet a local code ((eg., Chicago), the following fuse
dodo accessories are available for field installation.
Unitary Products Group
Electric Heat
Correction
Factors
Nominal Voltage
Voltage
KW Cap
Multipier
1.00
0.92
0.92
208
208
240
230
480
460
600
575
0.92
Fuse Block
2FB04700425
2FB04700546
208240 Wits
460 Volts
15
530.18 -TG 1 Y
FIELD WIRING
CONTACTOR
GROUND
LUG
•
L
TYPICAL POWER WIRING
FIELD -SUPPLIED
DISCONNECT
r ? SINGLE
-r-> PHASE
-11- -0-- 0- - > POWER
L J SUPPLY
REFER TO THE ELECTRICAL DATA
TABLES TO SIZE THE DISCONNECT
SWITCH, OVERCURRENT PROTEC-
TION AND WIRING.
T
I
I I
GROUNDL
LUG
CONTACTOR
L
•
L
FIELD -SUPPLIED
DISCONNECT
r1
1 r.
—I -0-Y13--r-
L J
THREE
PHASE
POWER
SUPPLY
TYPICAL CONTROL WIRING
COOLING ONLY (24 VOLT THERMOSTAT)
COOLING ONLY (24 VOLT THERMOSTAT)
THERMOSTAT` UNIT TERMINAL
TERMINALS STRIP T01
If•veliT“Valtiirxr =WASP
COOLING / HEATING (ELECTRONIC THERMOSTAT)
MULTI -STAGE
ADO
JUMPER
ADD
JUMPER
THERMOSTAT
TERMINALS
UNIT TERM NAL
STRIP TBI 24 VOLT
TRANSFORMER
NOT
USED
4
EJECTROLSC PWOORMMUME THERMOSTAT 2ETSSTOMIN P10.MCES SUBBASE)
WEE. STALE COOLING M NOT REQUIRED,. UNITE LESS ECONOMIZER.
SECO. STAGE .ATINO 13 ONLY REEPAREC ON UNITS WIN • two STAGE
ELECTRIC HEATER
TO REMOTE SENSOR
2711040702224 IF USED
TOR
PS
ialn To CLOSE THWm E OUTDOOR eWNONCER°ALPEAi . wIENN E.
COOLING / HEATING (24 VOLT THERMOSTAT)
ADD
JUMPER
COOLING/HEATING (24 VOLT THERMOSTAT)
THERMOSTAT'
TERMINALS
UNIT TERMINAL
STRIP TBI
24 VOLT
TRANSFORMER
'24 VOLT THERMOSTAT 2710170102. IF THE UNIT HAS AN ECONOMIZER
REMOVE JUMPER J1 FROM TERMINALS B AND ID ON TOE RELAY BOARD
TO PREVENT SIMULTANEOUS OPERATION OF TME COMPRESSOR AND
TME ECONOMIZER. IF YOU WANT TO CONTROL ]MER ECONOMIZER ON A
SECOND STAGE OF COOLING OR NAVE AND ELECTRIC MEAT ACCESSORY
WITH TWO STAGES OF MEAT, USE THERMOSTAT 2TI1501024
COOLING / HEATING (ELECTRONIC THERMOSTAT)
SINGLE STAGE
COOLING / HEATING (ELECTRONIC THERMOSTAT)
SINGLE STAGE
THERMOSTAT'
TERMINALS UNIT TERMINAL
STRIP TBI
24 VOLT
TRANSFORMER
'ELECTRONIC PROGRAMMABLE THERMOSTAT 2Em]N10240NO.UDESSUBSASEI.
IF THIS UNIT CASAND ECOIOM12ER REMOVE MMPER 11 FROM TERMINALS4 AND
ON THE RELAY BOARD TO PREVENT SWLTANEOUS OPERATION OF THE
COMPRESSOR AND THE ECONOMIZER M YOUWANT TO CONTROL TIE
ECONOMIZER ON A SECOND STAGE OF COOLING, USE THERMOSTAT 2E10470022A.
16 Unitary Products Group
. UNIT DIMENSIONS (DCE AND DCG - 3, 4, 5 & 6 TON)
FIELD-SUPPUED
DISCONNECT SWITCH
LOCATION
(Direct -Drive units)
CONTROL
BOX
ACCESS
BLOWER
ACCESS
DHE Units
485 Ton
CONDENSER
SCROLL
COMPRESSOR
ACCESS
ELECTRIC
HEAT
ACCESS
3(4" PVC FEMALE
COND. DRAIN
(See Detail "A")
BOTTOM SUPPLY
S RETURN AIR
OPENINGS (SEE NOTE)
B - POWER WIRING ENTRY
A - CONTROL WIRING ENTRY
8-3/8
All dimensions are in inches. They are
subject to change without notice. Certified
dimensions will be provided upon request.
FIELD -SUPPLIED
DISCONNECT SWITCH
LOCATION
(Direct -Drive units)
FILTER
ACCESS -
CONTROL
BOX
ACCESS
BLOWER
ACCESS
2-1/2
UNIT BASE WITH RAIL
Shown separately to illustrate
bottom duct openings and
power connection locations.
NOTE: For curb -mounted units,
refer to the duct hanger dimensions
of the curb for the proper size of the
supply and return air duct connections.
VENT AIR
CUTLET 11000
CONDENSER
530.18 -TG 1 Y
FILTER
ACCESS
BLOWER MOTOR1010
ACCESS DECONNECTED
DISCONNECT SNATCLOCATION
MOUNTING BRACKET
FOR DISCONNECT SWITCH
(Shroud eeet", d ru N•
Chewerba,com eHelde
the blow•, romy.amWI)
WIRING ENTRY
(Ss.HDetail 1
A11 ACCESS
RAND nOTOR ACMFSS PTANFLTF.
. r , u" . .. • . ..
CONTROL BOX
UTILITIES ENTRY DATA
HOLE
KNOCKOUT
SIZE
(DIA.)
USED FOR
A
7/8" ,
Control Wring
(Side or Bottom)**
B
2" •
Power Wiring
(Side or Bottom)
C
1-5/8"
Gas Piping (Front)
D
1-1/2"
Gas Piping (Bottom)
*Knockouts In the bottom of the unit can be located by the
slice In the insulation.
**Do s5t remove the 2" knockout ring.
CLEARANCES
Front
DCE Units
24"
DCG Units
32"
Back
12" (Less Economizer)
36" (With Economizer
or Fixed Air/Motorized
Damper)
Left Side
(Filter Access)
24"(Less Economizer)
36" (With Economizer)
Right Side
(Cond. Coil)
24"
Below Unit
0"
Above Unitz
72" (For Condenser
Air Discharge)
SCROLL COMPR. 1 Units may be instated on combustible floors made horn
ACCESS wood or doss A, a or C roof covering material.
COMBUSTION AIR ' Units must be instated oudoors. Overhanging structures
INLET HOOD or shrubs should not obstruct condenser air discharge outlet
NOTES:
43/8 f1(:F Modell: Units end ductwork are approved for zero clearance to
combustible =tenets when equipped with electric healers.
DCG Models: A 1' dearance must be provided between any combusti-
ble material and the supply air ductwork br a
distance of 3 feet from the unit.
The products of combustion must not be allowed to
accumulate within a confined space and recirculate.
Locate unit so that the vent air outlet hood is at least:
• Three (3) feet above any forced air inlet located within 10
horizontal feet (excluding those integral to the unit).
• Four (4) feet below, 4 horizontal feet from, or 1 foot above
/ 2.1/2 any door or gravity air inlet into the building.
Jj • Four (4) feet from electric meters, gas meters, regualtors
and relief equipment.
32-5/8
DCG UNITS
3-6 TON
I
GAS HEAT
`----T ACCESS
GAS SUPPLY ENTRY
82-114 -- (1/2" NPTI AT GAS VALVE)
314° PVC FEMALE
COND. DRAIN
(See Detail "Al
5-3(8
32-1/4
BOTTOM SUPPLY
& RETURN AIR
OPENINGS (SEE NOTE)
B - POWER WIRING ENTRY
1
D
GAS SUPPLY ENTRY
(1/2" NPTI AT GAS VALVE)
32-1/4 UNIT BASE WITH RAIL$
Shown separately to Illustrate
bottom duct openings, power and
gas piping connection locations.
NOTE: For curb -mounted units,
rater to the duct hanger dimensions
of the curb for the proper size of the
supply and return air duct connections.
A - CONTROL WIRING ENTRY
Unitary Products Group
8.3(8
E>
RETURN AIR
SUPPLY AIR
CONDENSER AIR
''. OUTDOOR AIR
(Economizer)
17
loo
530.18-TG1Y
UNIT DIMENSIONS - CONT'D. (DCE and DCG - 3, 4, 5 & 6 TON)
171/2
111
REAR VIEW 61h 171/2
SIDE SUPPLY AND RETURN AIR
DUCT OPENINGS
4%
77/8
DUCT COVERS - Units are shipped with all air duct
openings covered.
For side duct applications;
1.Remove and discard the supply and return air duct
covers.
2.Connect ductwork to duct flanges on the rear of the
unit.
For bottom duct applications;
1. Remove the side supply air duct cover to gain access
to the bottom supply air knockout panel.
2. Remove and discard the bottom knockout panel.
3. Replace the side duct cover.
4. With filter section access panel removed from the
unit, remove and discard the bottom return air
knockout panel.
5. Replace the filter access panel.
1.4-2i271/22—.1 15/8 r---1-5/8
ool
REAR VIEW
27.271/2
o1c
191/2 2 'f`
DETAIL "A"
UNIT WITH ECONOMIZER RAINHOOD
4
W CONDENSATE
DRAIN
(must be trapped)
447/8
L.H. END VIEW
1!193/4,--►
loo _f
REAR VIEW
REAR VIEW
FIXED
OUTDOOR
AIR DAMPER
12
MOTORIZED
DAMPER
16-1/2
447/6
101/4
B 31/2
\ A�
81/4
43/8
L.H. END VIEW
DETAIL "B"
UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD
3/4' X 1.1/4" WIDE GASKETING FOR CURB
FRAME AND ALL DUCT SUPPORT SURFACES
UNIT BASE
WOOD NAILER— UNIT BASE RAILS
14"
8" MIN. ABOVE FINISHED ROOF — ' COUNTERFLASHING
CURB FRAME— CANT STRIP
INSULATION AND ROOFING MATERIAL
INSULATION
UNIT AND CURB APPLICATION
18
ROOF DECK AND SUPPORT STRUCTURE
DIMENSION "A"
FIXED
OUTDOOR 12
AIR DAMPER
MOTORIZED
DAMPER
Unitary Products Group
. ROOF CURB DIMENSIONS - (DCE and DCG - 3, 4, 5 & 6 TON)
BACK
OF UNIT
RETURN'
AIR
DUCT
SUPPORT RAILS
SUPPLY*
AIR
2" TYP.--->,
530.18-TG1Y
SCROLL COMPRESSOR
AND CONDENSER END
OF UNIT
19-1/2"
37-1/4"
DUCT SIZES:
Supply Air = 19" x 19"
Return Air = 19" x 19"
FRONT
73" OF UNIT
'Supply and Return Air (including duct support rails)
shown are typical for bottom duct applications.
For location of horizontal duct applications
(on back of unit), refer to Unit Dimension details.
COMPONENT WEIGHTS AND CENTER OF GRAVITY
BASIC UNIT
OPTIONS/ACCESSORIES
DCGCORNER
SIZE
(heat)
UNIT WEIGHT"
(lbs.)
WEIGHTS*
(location, lbs.)
DCE
UNIT WEIGHT'
(lbs.)
CORNER WEIGHTS'
(location, lbs.)
DESCRIPTION
WEIGHT
(lbs.)
"A"
"B"
"C"
"D"
036
(40 Mbh)
625
180
172
133
140
036
565
160
157
123
125
ECONIMIZER
50
036
(79 Mbh)
635
180
177
138
140
048
615
173
170
135
137
MOTORIZED
OUTDOOR
AIR DAMPER
26
048
(60 Mbh)
675
193
185
145
152
060
640
180
177
140
143
048
(99 Mbh)
685
193
190
150
152
072
720
171
196
189
164
ELECTRIC
(n0 EAI
DCE only
5 7
KW
18
(79 Mbh) 060
700
200
192
150
158
• Might = Unit + Economizer.
/ CORNER "D"
10-115
23
060
(99 Mbh)
710
200
197
155
158
20KW30
28
072
(79 Mbh)
775
186
209
201
179
ROOF MOUNTING
CURB
92
072
(99 Mbh)
785
186
214
206
179
RELIEF/FIXED
AIR DAMPER
10
BELT -DRIVE
BLOWER
5
CORNER "A"
DIM. 3 - 5 TON 6 TON
Y 19-3/4" 22"
BACK OF UNIT
82t/4
APPROXIMATE
X 40-3/4" 44" CENTER OF GRAVITY
Unitary Products Group
FRONT OF UNIT
CORNER"B'
Y
CORNER "C"
CONDENSER COIL
END OF UNIT
19
530.18-TGW
TYPICAL APPLICATIONS
ROOF JACK
7 INSTALLATION
0 ci
I
I I I
IFI
1111111MMMINNINI.INEMSMINS111111
------
ROOF CURB
INSTALLATION
SLAB ON GROUND
INSTALLATION
I)
FIELD -SUPPLIED
DISCONNECT SWITCH
TYPICAL ROOF -TOP INSTALLATION
(MODEL DCG SHOWN)
J.
CONDENSATE
TRAP
CONTROL WIRING
TO TO INDOOR
POWER THERMOSTAT
SUPPLY
OSUPPLY AIR
DUCT
RETURN AIR
DUCT
ROOF CURB
MANUAL
GAS SHUT-OFF
VALVE
TO GAS SUPPLY LINE
20 Unitary Products Group
MECHANICAL SPECIFICATIONS
GENERAL DESCRIPTION
Units shall be factory -assembled, single packaged, (DCG
Electric Cooling/Gas Heat, DCE Electric Cooling/Optional
Electric Heat), designed for outdoor mounted installation. Units
shall have minimum SEER ratings (036 thru 060) of 10.0 and
minimum EER ratings (072) of 9.0. They shall have built in field
convertible duct connections for down discharge supply/return
or horizontal discharge supply/return, and be available with
factory installed options or field installed accessories.
The units shall be factory wired, piped, charged with R-22
refrigerant and factory tested prior to shipment. All unit wiring
shall be both numbered and color coded. Enclosed in each unit
shall be a factory test log sheet consisting of the unit tested
pressures, temperatures and amps, as tested prior to
shipment.
All units shall be manufactured in a facility certified to ISO 9001
standards, and the cooling performance shall be rated in
accordance with DOE and ARI test procedures. Units shall be
UL listed and classified to ANSIZ21.47 standards and UL
1995/CAN/CSA No. 236-M90 conditions.
UNIT CABINET
1. Unit cabinet shall be constructed of G90 galvanized steel,
with exterior surfaces coated with a non -chalking, powered
paint finish, certified at 750 hours salt spray test per ASTM -
B117 standards.
2. Indoor blower section shall be insulated with up to 1" thick
insulation, coated on the air side. Aluminum foil faced
insulation shall be used in the furnace compartment and be
fastened with ridged fasteners to prevent insulation from
entering the air stream.
3. Cabinet panels shall be "large" size, easily removable for
servicing and maintenance.
4. Full perimeter base rails shall be provided to assure reliable
transit of equipment, overhead rigging, fork truck access
and proper sealing on roof curb applications.
5. Disposable 1" filters shall be furnished and be accessible
through a removable access door, sealed air tight. Units
filter track shall be designed to accommodate either 1" or
2" filters.
6. Fan performance measuring ports shall be provided on the
outside of the cabinet to allow accurate air measurements
of evaporator fan performance without removing panels or
creating air by-pass of the coils.
7. Units vertical discharge and return duct configuration shall
be designed to fit between standard 24" O.C. beams without
modification to building structure, duct work and base unit.
8. Condensate pan shall be internally sloped and conform to
ASHARE 62-89 self -draining standards. Condensate con-
nection shall be a minimum of 3/4" I.D. female and be a
ridged mount connection.
INDOOR (EVAPORATOR) FAN ASSEMBLY
1. Fan shall be direct drive, multi -speed, or a factory installed belt
drive, adjustable -pitch motor pulley option. Job site selected
(B. H. P.) brake horse power shall not exceed the motors name-
plate horse power rating, plus the service factor. Units shall be
designed not to operate above service factor.
530.18 -TG 1 Y
2. Fan wheel shall be double -inlet type with forward -curved
blades, dynamically balanced to operate smoothly through-
out the entire range of operation. Airflow design shall be
constant air volume.
3. Bearings shall be sealed and permanently lubricated for
longer life and no maintenance.
OUTDOOR (CONDENSER) FAN ASSEMBLY
1. The outdoor fan shall be of the direct -driven propeller type,
discharge air vertically, have aluminum blades riveted to
corrosion resistant steel spider bracket and shall be dy-
namically balanced for smooth operation.
2. The outdoor fan motor shall be totally enclosed with perma-
nently lubricated bearings and internally protected against
overload conditions.
REFRIGERANT COMPONENTS
1. Compressors:
A. Shall be fully hermetic type, advanced scroll design, with
patented check valve to eliminate backspin noise at shut-
down, internally protected with internal high-pressure re-
lief and over temperature protection. The hermetic motor
shall be suction gas cooled and have a voltage range of +
or - 10% of the unit nameplate voltage.
B. Shall have sound muffling to minimize vibration and
noise, and be externally isolated on a dedicated, inde-
pendent mounting.
2. Coils:
A. Evaporator and condenser coils shall have aluminum
plate fins mechanically bonded to seamless internally -
enhanced copper tubes with all joints brazed. Special
Phenolic coating shall be available as a factory option.
B. Evaporator and Condenser coils shall be of the direct
expansion, draw-thru design.
3. Refrigerant Circuit and Refrigerant Safety Components
shall include:
A. Independent fixed -orifice expansion devices.
B. Filterdrier/strainer to eliminate any moisture orforeign matter.
C. Accessible service gage connections on both suction
and discharge lines to charge, evacuate, and measure
refrigerant pressure during any necessary servicing or
troubleshooting, without losing charge.
D. The refrigeration system shall provide at least 15° F of
liquid sub -cooling at design conditions.
4. Unit Controls:
A. Unit shall be complete with self contained low -voltage
control circuit protected by a resetable circuit breaker
fuse on the 24 volt transformer side.
B. Unit shall incorporate a lock -out circuit which provides
reset capability at the space thermostat or base unit,
should any of the following standard safety devices trip
and shut off compressor:
(1) - Loss-of-charge/Low-pressure switch.
(2) - High-pressure switch.
(3)- Freeze -protection thermostat, evaporator coil.
If any of the above safety devices trip, an LED (light -emitting
diode) indicator shall illuminate.
C. Unit shall incorporate "AUTO RESET" compressor over
temperature, over current protection.
D. Unit shall operate with conventional thermostat designs
and have a low voltage terminal strip for easy hook-up.
Unitary Products Group 21
530.18 -TG 1 Y
GAS HEATING SECTION (DCG Models)
1. Shall be designed with induced draft combustion with post
purge logic, energy saving direct spark ignition and redun-
dant main gas valve. Ventor wheel shall be constructed of
stainless steel for corrosion resistance.
2. The heat exchanger shall be of the tubular type, con-
structed of T1-40 aluminized steel for corrosion resistance
and allowing minimum mixed air entering temperature of
25° F.
3. Burners shall be of the in -shot type, constructed of alumi-
num coated steel and contain air mixture adjustments.
4. All gas piping shall enter the unit cabinet at a single location,
through either the side or bottom, without any field modifi-
cations.
5. An integrated control board shall provide timed control of
evaporator fan functioning and burner ignition.
6. Heating section shall be provided with the following mini-
mum protection:
A. Primary and auxiliary high-temperature limit switches.
B. Induced draft motor speed sensor.
C. Flame roll out switch (automatic reset).
D. Flame proving controls.
ELECTRIC HEATING SECTION (DCE Models)
1 An electric heating section, with nickel chromium elements,
shall be provided in a range of 5 thru 30 KW, offering two
stages of capacity - 16 KW and above on 208/230 volt
heaters and 20 KW and above on 460 and 575 volt heaters.
2. The heating section shall have a primary limit control(s) and
automatic reset, to prevent the heating element system
from operating at an excessive temperature.
3. The Heating Section assembly shall slide out of the unit for
easy maintenance and service.
4. Units with Electric Heating Sections shall be wired for a single
point power supply with branch circuit fusing (where required).
UNIT OPERATING CHARACTERISTICS
1. Unit shall be capable of starting and running at 125° F
outdoor temperature, exceeding maximum load criteria of
ARI Standard 210/240.
2. The compressor, with standard controls, shall be capable
of operation down to 45° F outdoor temperature. Accessory 1.
low ambient kit shall be available for operation to 0° F
OPTIONAL OUTDOOR AIR
(Shall be made available by either/or):
1.
ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER -
Outdoor and return air dampers that are interlocked and
positioned by a fully -modulating, spring -return damper ac-
tuator. The maximum leakage rate for the outdoor air intake
dampers shall not exceed 2% when dampers are fully
closed and operating against a pressure differential of 0.5
IWG. A unit -mounted potentiometer shall be provided to
adjust the outdoor and return air damper assembly to take
in CFM of outdoor air to meet the minimum ventilation
requirement of the conditioned space during normal opera-
tion. During economizer operation, a mixed -air temperature
control shall modulate the outdoor and return air damper
assembly to prevent the supply air temperature from drop-
ping below 55°F. Changeover from compressor to econo-
mizer operation shall be provided by an integral electronic
enthalpy control that feeds input into the basic module. The
outdoor intake opening shall be covered with a rain hood
that matches the exterior of the unit. Water eliminator/filters
shall be provided. Simultaneous economizer/compressor
operation is also possible. Dampers shall fully close on
power loss.
2. DUAL INPUT DIFFERENTIAL ELECTRONIC ENTHALPY
AUTOMATIC ECONOMIZER - Outdoor and return air
dampers that are interlocked and positioned by a fully -
modulating, spring -return damper actuator. The maximum
leakage rate for the outdoor air intake dampers shall not
exceed 2% when dampers are fully closed and operating
against a pressure differential of 0.5 IWG. A unit mounted
potentiometer shall be provided to adjust the outdoor and
return air damper assembly to take in the design CFM of
outdoor air to meet the minimum ventilation requirement of
the conditioned space during normal operation. During
economizer operation, a mixed -air temperature control
shall modulate the outdoor and return air damper assembly
to prevent the supply air temperature from dropping below
55°F. Changeover from compressor to economizer opera-
tion shall be provided by two integral electronic enthalpy
controls - one that senses outdoor air and one that senses
indoor air. Both enthalpy sensors supply input to the logic
module which modulates both sets of dampers for maxi-
mum economizer savings. The outdoor intake opening shall
be covered with a rain hood that matches the exterior of the
unit. Water eliminator/filters shall be provided. Simultane-
ous economizer/compressor operation is also possible.
Dampers shall fully close on power loss.
OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE
3. Unit shall be provided with fan time delay to prevent cold air 2.
delivery before heat exchanger warms up. (Gas heat only)
ELECTRICAL REQUIREMENTS
All unit power wiring shall enter unit cabinet at a single factory
provided location and be capable of side or bottom entry, to
minimize roof penetrations and avoid unit field modifications.
Separate side and bottom openings shall be provided for the
control wiring.
STANDARD LIMITED WARRANTIES
Compressor- 5 Years
Heat Exchanger- 10 Years
Elect. Heat. Elem.- 5 Years
Parts - 1 Year
3.
ROOF CURB - 14" AND 8" high, full perimeter knockdown
curb with hinged design for quick assembly.
MANUAL OUTDOOR DAMPER - provides 0% through
35% or 0% through 100% outdoor air capability (field
adjustable). Designed for duct mounted side supply/return
applications. Includes a hood and a screen assembly.
OUTDOOR COIL GUARD - Prevents coil damage.
4. BAROMETRIC RELIEF DAMPER - Contains a rain hood,
air inlet screen, exhaust damper and mounting hardware.
Used to relieve internal air pressure through the unit during
economizer operation.
5. PROPANE CONVERSION KIT- Contains new orifices and
gas valve regulator to convert from natural to L.P. gas.
6. LOW NOX - Required to reduce the emission of nitrogen
oxides below 40 nano grams per joule.
22 Unitary Products Group
•
7. HIGH ALTITUDE - NATURAL GAS - Required for applica-
tions between 2000 and 6000 feet altitude.
8. HIGH ALTITUDE - PROPANE GAS - Required for applica-
tions between 2000 and 6000 feet altitude. Must be used
with propane conversion kit.
9. GAS PIPING - Contains 1/2" pipe nipples, fittings and gas
cock (including panel assess gaskets) required for bottom
gas supply connection with external shut-off.
10. BURGLAR BARS - Designed to work with above roofcurbs.
Fits duct openings of curb supply and return air openings.
11. THERMOSTATS - Multiple models available from A.C.O.,
M.C.O., Electronic or Electrical Mechanical versions.
530.18 -TG 1 Y
12. ANTI -RECYCLE TIMER - Assures 5 -minute off -time be-
tween compressor cycles.
13. LOW AMBIENT KIT - Provides unit cooling operation down
to 0°F.
14. ELECTRIC HEAT - Slide -in design, provides single point
power and ranges from 5 to 30 KW.
OTHER FACTORY INSTALLED OPTIONS
1. HIGH PERFORMANCE BELT DRIVE MOTOR
2. TECHNICOAT PHENOLIC COATED COND. COIL
3. ELECTRONIC ENTHALPY ECONOMIZER
4. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER
Unitary Products Group 23
•
aEFFICIENCY
RATING
CERTIFIED
ama
208230-1.60 VOLT
MODELS ONLY
208230, 460 VOLT
MODELS ONLY
JYORK'
LISTED
208!230, 575 VOLT
MODELS ONLY
Heating and Air Conditioning
SHU 10M 898 1.32 Codes: EBY,EGY,RTY
Unitary Products Group
5005 Interstate Drive North, Norman, Oklahoma 73069
Subject to change without notice. Printed in U.S.A.
Copyright ® by York International Corporation 2000. All Rights Reserved.
ISO
9001
CERTIFIED
Proud Sparrow
of the 2000
U.S. Olympic Teem
530.18-TG1Y(500)
Supersedes: 530.18-TG1Y (698)
5/1/2014
City of Tukwila
Department of Community Development
ABDIRISAK AHMED
14101 TUKWILA INTERNATIONAL B
TUKWILA, WA 98168
RE: Permit No. M13-0210
ABU-BAKR ISLAMIC CENTER
14101 TUKWILA INTERNATIONAL BL
Dear Permit Holder:
Jim Haggerton, Mayor
Jack Pace, Director
In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building
Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National
Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and
become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of
such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun
for a period of 180 days. Your permit will expire on 6/14/2014.
Based on the above, you are hereby advised to:
1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each
inspection creates a new 180 day period, provided the inspection shows progress.
-or-
2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire.
Address your extension request to the Building Official and state your reason(s) for the need to extend your permit.
The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your
extension request is granted, you will be notified by mail.
In the event you do not call for an inspection and/or receive an extension prior to 6/14/2014, your permit will become null and void
and any further work on the project will require a new permit and associated fees.
Thank you for your cooperation in this matter.
Sincerely,
Jenn
Per
ul\
fer Marshall
t Technician
File No: M13-0210
6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665
¶ERMIT COORD COPY
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: M13-0210 DATE: 11-12-13
PROJECT NAME: ABU-BAKR ISLAMIC CENTER
SITE ADDRESS: 14101 TUKWILA INTERNATIONAL BL
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS:
Building ivision ` , I
NelliPreMvention
A [4411$
Public Works
n
Structural
Planning Division
n
❑ Permit Coordinator V
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-14-13
Complete
Incomplete
Not Applicable
CI
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUES/THURS ROUTING:
Please Route 41 Structural Review Required n No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS: .
Approved
Notation:
DUE DATE: 12-12-13
Approved with Conditions Not Approved (attach comments) n
REVIEWER'S INITIALS: DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials:
Documents/routing slip.doc
2-28-02
ALL HITECH HEATING & A/C L.
Washington State Department of
Labor & Industries
Page 1 of 2
ALL HITECH HEATING & A/C LLC
Owner or tradesperson
FAISAL, MUHAMMAD
Principals
FAISAL, MUHAMMAD
WA UBI No.
603 004 182
14724 NE 4TH PL
BELLEVUE, WA98007
425-747-0677
KING, County
Business type
Limited Liability Company
License
Verify the contractor's active registration / license / certification (depending on trade) and any past violations.
Electrical Contractor
License specialties
HVAC/RFRG
License no.
ALLHIHH873MW
Effective — expiration
07/18/2013 — 07/18/2015
Designated administrator
FAISAL, MUHAMMAD
License type
Electrical Administrator
Bond
American States Insurance Co
Bond account no.
32S208107
Received by L&I
07/18/2013
Insurance
No insurance accounts during the previous 6 year period.
Savings
No savings accounts during the previous 6 year period.
License Violations
No license violations during the previous 6 year period.
Active.
Meets current requirements.
ACTIVE
License no.
FAISAM*979MW
$4,000.00
Effective date
07/12/2013
Workers' comp
No active workers' comp accounts during the previous 6 year period.
https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603004182&LIC=ALLHIHH873MW&S... 12/16/2013