Loading...
HomeMy WebLinkAboutPermit M13-0210 - ABU-BAKR ISLAMIC CENTER - REPLACE ROOF TOP UNITABU-BAKR ISLAMIC CENTER 14101 TUKWILA INTERNATIONAL BLVD EXPIRED 06/14/14 M13-0210 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT` Parcel No: 1610000125 Permit Number: M13-0210 Address: 14101 TUKWILA INTERNATIONAL Issue Date: 12/16/2013 BLVD 1 Permit Expires On: 6/14/2014 Project Name: ABU-BAKR ISLAMIC CENTER Owner: Name: ABU-BAKR ISLAMIC CTR OF WA Address: PO BOX 68069 , TUKWILA, WA, 98169 Contact Person: Name: ABDIRISAK AHMED Phone: (206) 251-6976 Address: 14101 TUKWILA INTERNATIONAL B , TUKWILA, WA, 98168 Contractor: Name: ALL HITECH HEATING & A/C LLC Address: 14724 NE 4 PL, BELLEVUE, WA, 98007 License No: ALLHIHH873MW Lender: Name: Address: Phone: (425) 747-0677 Expiration Date: DESCRIPTION OF WORK: REMOVE & REPLACE OLD ROOFTOP GAS PACKS LIKE FOR LIKE Valuation of Work: $5,000.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $249.00 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer Distric: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature; Date: t ` 1( Q113 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws g ating • onstruction or the performance of work. I am authorized to sign and obtain this development p; an •_�; - the conditions attached to this permit. Signature: Print Name: 4-1041-1 se.k..J(. YY) Date: 1 ( r 1 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 0703 MECH EQUIP EFF 1800 MECHANICAL FINAL 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKTylig Community DevelopmeW epartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical P Project No. Date Application Accepted: Date Application Expires \ (` or office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: 10k �111\KM' 14 JW'1 \ ,,W Tenant Name: Pt\ C King Co Assessor's Tax No.: vll')...\ -0) sS Suite Number: Floor: ,PROPERTY OWNER - Name: (\ Address: 19\0) r"\--V\\kW(LA 1111 v City \V\\<_�,.111`I� Statekl• Zip C�lD\6D CONTACT,PERSON =person receiving all, project communication `" Name: kok,\,,s4,.., " I A v.- Address: \L\t.7�� NQ u - p Address: (/ 61 /U/i A ►t1 /� Zs r ' City: ) V.Ck)l 1w State: lidZip:9oj G! ' Phone:2-06 2C1-7& /, Fax: Email: a✓JV.(lja�'(f GClre °"t Imauk'- t(fv"i New Tenant: ❑ Yes ❑.. No MECHANICAL CONTRACTOR INFORMATION Company Name: 1T� , y \�‘_‘..,\ \s\Nz'� \13L^ Address: \L\t.7�� NQ u - p City:,bjo State:W,�nTT'' Zip:q.zp�-7 Phone: n 4:4..._,..).7q. _$.63Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ 0 r 0 Describe the scope of work in detail: 9.\\'_yvv g \ ���\f� 17 D\� �Q\ �� l�(kf‘S L�\cam FOR L\ 1<`z Use: Fuel Type: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Electric ❑ Gas Other: H:\Apphcations\Forms-Applications On Lme\201 I Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh ti Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit type Qty' Furnace <100k btu 7. Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type .Qty; Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment 'Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - • Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY - LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: Print Name: ORI ED AGENT: Mailing Address: Atilkyv* "or\ (c/ dw w lA �a uL11, H:1Appl'cations \Forms -Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Day Telephone: .7C6 ' �i ((O? (/ City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY I PAID M13-0210 Address: 14101 TUKWILA INTERNATIONAL BLVD 1 Apn: 1610000125 MECHANICAL $127.12 PERMIT FEE PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R398 R000.322.100.00.00 R000.322.102.00.00 $101.70 $25.42 $127.12 Date Paid: Monday, December 16, 2013 Paid By: ABU-BAKR ISLAMIC CENTER Pay Method: CREDIT CARD 140043 Printed: Monday, December 16, 2013 10:32 AM 1 of 1 CRWSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I ACCOUNT PermitTRAK I QUANTITY I PAID $121.88 M13-0210 Address: 14101 TUKWILA INTERNATIONAL BLVD 1 Apn: 1610000125 $121.88 MECHANICAL $121.88 PERMIT FEE 000.322.100.00.00 $65.00 PERMIT ISSUANCE BASE FEE 000.322.100.00.00 $32.50 PLAN CHECK FEE 000.322.102.00.00 TOTAL FEES PAID BY RECEIPT: R82 $24.38 $121.88 Date Paid: Tuesday, November 12, 2013 Paid By: ABDIRISAK A AHMED ABU-BAKR ISL . Pay Method: CREDIT CARD 398424 Printed: Tuesday, November 12, 2013 4:04 PM 1 of 1 RWSYSTEMS SEPARATE PERMIT REQUIRED FOR: 0 MAcnanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION arcE D�IDIKI .--Au ovosD nun' 6 MAL 910-T11IA1 a• N NAf✓1w6H+ AIR SEM 50 sate EVEPORCIVE COMER F. io JI%le r ,T n OO54D m�g,J6tl01 PlFlmll DOLT SEIRo1 Sn•a YR to - ILO MARY _..!I FL:1IC Y - WELD 077.11 RCM MUT Ovl®MGA, r e�- O 0 0 0 0 RSD WOON O Dnr,&L IDR W-2..0. 0l \ eu 00\ muni C'• v0D R. DP. ON *10015r TOP RA CUNT N CEY6 IRC6hM KAT egata 6TG MUTE MIM 50055510 1WORK 601469 MINA CULT 02lTOR 'I 16.ND 1 MCI SIM 6 MOE INSUUTICN TITOT FOR O00. 1461 FLOOR PLAN s,..r 1/r -1r mq9-co-lo REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. WOTE: Revisions will require a new plan submittal and may include additional plan review fees. j UST. Y 6558 C13 51(2 ROLM NTN -W OO6LR I EVOEWI D FOR CODE CIS iPLIANCE NOVAPPROVED 2 / 2013 . 1 J City if RA wiOa BUOLLDiI ' AAMON RECEIVED CITY OF TUKWILA GIOV 1 "12013 PERMIT CENTER all N IIRRIDR y'1NDSiD 13-m.02A0 u-zSLbLS�ULi" U pcx aool 1\1, (92—DZI,0 Plan reviewFlo 10 h Approval of con the violation of an app ved FrafJ asks=Wow. . not authorize or ordinance. Receipt ed: Dft DEHAAS ENGINEERING 56210 MARK[ VAY DR. S. 1GR NO.N05. Y Sb1S0 DRAWING mR:10 oR® PD ISS 9 E D Iu1,3/12/99 REVISIONS 5(0(0 TITLE HVAC FLOOR PLAN 21 CLUB TUKWGLA. WA IRD,E CI Till MEM a1.CR TORR. 999 1OILI NC. M-2 2 OF 2 ay Of INhvO HEATING & AIR CONDITIONING SUBMITTAL D%ATRLEc Order #: Project: All Hi -Tech Project #: Location: For: Approval Date: 10/28/2013 REVIEWED FOR CODE COMPLIANCE APPROVED NOV 2 7 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA NOV t =2 2013 PERMIT CENTER Unitary Sales Tool v1.5.7.30 Information is sub)ect to change without notice. Check local codes. Printed 10282013 Date 10/28/2013 Project Name All Hi -Tech Project Number Client / Purchaser Submittal Summary Page HEATING 8 AIR CONDITIONING Qty Tag # Model # Description 1 ZS-04NO7AFAAA2 4 Ton, Single Packaged R -410A Air Conditioner, 13.0 SEER / 11.0 EER, Single Stage Cooling, 75 MBH Input Aluminized Steel, Single Stage Gas Heat, 1 HP Direct Drive Blower, 1" Throwaway Filters, 208/230-1-60, Microchannel Condenser Coil, Galvanized Steel Drain Pan 2EE04703724 Single Enthalpy Economizer (Downflow or Horizontal Unit) with Hood Kit Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) 1 1 RD0410 Equipment start-up and commissioning by a factory trained technician is recommended. Contact your supplying distributor or sales representative for additional information & guidance. Unitary Sales Tool v1.5.7.30 Information is subject to change without notice. Check local codes. Printed 10/28/2013 Coleman HEATING A AIR c0NGm0NING 3-6 Ton Package Single Package R -410A Air Conditioner Page: 3 Project Name: All Hi -Tech Unit Model #: ZS-04NO7AFAAA2 Quantity: 1 System: ZS-04NO7AFAAA2 t,;ooung rerrormance Total capacity 53 2 MBH Sensible capacity 37.1 MBH Refrigerant type R -410A Seasonal Efficiency (at ARI) 13.00 SEER Efficiency (at ARI) 11.00 EER Ambient DB temp. 84.9 °F Entering DB temp. 80.0 °F Entering WB temp. 67.0 °F Leaving DB temp. 58.5 °F Leaving WB temp. 56.4 °F Power input (w/o blower) 3.42 kW Sound power 80 dB(A) Gas Heating Performance Entering DB temp. 60 °F Heating output capacity (Max) 59 MBH Supply air 1600 CFM Heating input capacity (Max) 75 MBH Leaving DB temp. 94.1 °F Air temp. rise 34.1 °F SSE 81.6 % AFUE 80.9 % Stages 1 Supply Air Blower Performance Supply air 1600 CFM Ext. static pressure 0.87 IWG Unit static resistance 0.11 IWG Blower speed 1097 RPM Duct location Bottom Motor rating 1.00 HP Actual required BHP 0.75 HP Power input 0.70 kW Elevation 433 ft. Drive type DIRECT Speed tap 5 Electrical Data Power supply 230-1-60 Unit min circuit ampacity 29.5 Amps Unit max over -current protection 40 Amps Dimensions & Weight Hgt 33 in. Len 83 in. Wth 45 in. Weight with factory installed options 596 lbs. Clearances Right 24 in. Front 32 in. Back 36 in. Tnn 79 in nnHnm rl in I oft ZR in Note: Please refer to the tech guide for listed maximum static pressures .ALIS cEHFIFIEo. 4 Ton • Coleman Units are Manufactured at an ISO 9001 Registered Facility and Each Rooftop is Completely Computer -Run Tested Prior to Shipment. Unit Features • Unit Cabinet Constructed of Powder Painted Steel, Certified At 1000 Hours Salt Spray Test (ASTM B-117 Standards) • Through -the -Curb and Through -The -Base Utility Connections • Either Supply and/or Return can be Field Converted from Vertical to Horizontal Configuration without Cutting Panels. • Full Perimeter Base Rails with Built in Rigging Capabilities • Galvanized Steel Drain Pan • Reciprocating Compressor • Single Stage Cooling • Solid Core Liquid Line Filter Driers • Microchannel Condenser Coil • 75 MBH Input Aluminized Steel, Single Stage Gas Nominal Heat • 1 HP Direct Drive Blower • Unit Ships with 1" Throwaway Filters with a Standard Filter Rack That Will Accept up to 2" Filters • Single Point Power Connection • Short Circuit Current: 5kA RMS Symmetrical Standard Unit Controller: Simplicity Control Board • An Integrated Low -Ambient Control, Anti -Short Cycle Protection, Lead -Lag, Fan On and Fan off Delays, Low Voltage Protection, On -Board Diagnostic and Fault Code Display. • Safety Monitoring - Monitors the High and Low -Pressure Switches, the Freezestats, the Gas Valve, if Applicable, and the Temperature Limit Switch on Gas and Electric Heat Units. The Unit Control Board will Alarm on Ignition Failures, Safety Lockouts and Repeated Limit Switch Trips. Warranty • One (1) Year Limited Warranty on the Complete Unit • Five (5) Year Warranty - Compressors and Electric Heater Elements • Ten (10) Year Warranty - Aluminized Steel Tubular Heat Exchangers Unitary Sales Tool v1 5 7 30 Information is subject to change without notice. Check local codes. Printed 10f28/2013 Colemant HEATING 8 AIR CONDITIONING 3-6 Ton Package Single Package R -410A Air Conditioner Page: 4 Project Name: All HI -Tech Unit Model #: ZS-04NO7AFAAA2 Quantity: 1 System: ZS-04NO7AFAAA2 Factory Installed Options ZS-04NO7AFAAA2 Product Category: Product Identifier: Nominal Cooling Capacity: Heat Type and Nominal Heat Capacity: Airflow: Voltage: Installation Options: Additional Options: Product Generation: • 2EE04703724 - Single Enthalpy Economizer (Downflow or Horizontal Unit) with Hood Kit (50.0 lbs) • 1 RD0410 - Barometric Relief Damper with Hood Kit (Downflow Unit or Duct Mounted) (6.0 lbs) z S -04 N07 A F A AA 2 Single Packaged R -410A Air Conditioner 13.0 SEER / 11.0 EER 4 Ton Single Stage Cooling 75 MBH Input Aluminized Steel, Single Stage Gas Heat 1 HP Direct Drive Blower 1" Throwaway Filters 208/230-1-60 Microchannel Condenser Coil Galvanized Steel Drain Pan Field Installed Accessories Unitary Sales Tool v1.5.7.30 Information is subject to change without notice. Check local codes. Printed 1028/2013 Coleman@ 3-6 Ton Package Page:5 Single Package R -410A Air Conditioner HEATING s RIR CONDmowNG Project Name: All Hi -Tech Unit Model #: ZS-04NO7AFAAA2 Quantity: 1 System: ZS-04NO7AFAAA2 Consolidated Drawing NOTES: I. FOR OUTDOOR USE ONLY. 2. WEIGHTS SHOWN ARE FOR COOLING ONLY UNITS. TONNAGE U N I OPERATING WEIGHT (LBS) CENTER OF GRAVITY LOCATION (BASE UNIT) 4 PO NT CORNER LOADS (LBSI (BASE UNIT) 3. MIN. CLEARANCES TO BE: T (BASE UNIT) X Y A 6 C D RIGHT SIDE: 24 [609,6] LEFT SIDE: 24 [609,6] (LESS ECONOMIZER) 3 ZS 468 12121 33 )838,2) 18.25 [463,61 114 (52] 16 [35] III [501 167 [161 36 [914,4] (WITH ECONOMIZER) FRONT: 24 [609,6] (COOLING/ELECTRIC HEAT) 4 ZS 541 [245] 31.50 [800,1) 18.50 [469,9) 138 [631 85 [391 122 [551 196 [891 32 [812,8] (GAS HEAT) REAR: 12 [304,8] (LESS ECONOMIZER) 5 ZS 569 (258) 37 [939,81 IS 1381] 105 (481 86 [391 110 1711 208 [941 36 1914,41 (WITH ECONOMIZER OR FIXED AIR/MOTORIZED DAMPER) 6 IS 640 12901 37 1939,81 15 13811 118 [541 96 [441 192 (871 234 (106) TOP: 12 [1828,81 BOTTOM: 0 [0] 31.62-_ [803,31 3 ZN 515 (2611 10 [10161 20 [5081 132 [601 125 [571 155 (101 164 [741 4. FOR SMALLER SERVICE AND OPERATIONAL CLEARANCES CONTACT YOUR APPLICATION ENGINEERING DEPARTMENT. 6.12 [155,5) 4 ZN 585 [2651 40 (10161 20 [5081 131 [611 121 [581 158 [721 161 [161 5. DOWNFLOW DUCTS DESIGNED TO BE ATTACHED TO ACCESSORY 1.25 ROOF CURB ONLY. IF UNIT IS MOUNTED SIDE SUPPLY, IT [184,0] 18.26 [463,7) - 5 ZN 590 [2681 40 110161 20 [5081 135 [611 128 [581 159 [721 168 [761 IS RECOMMENDED THAT THE DUCTS ARE SUPPORTED BY CROSS BRACES, AS DONE ON ACCESSORY ROOF CURBS. 1.80 - - 21.54 -- 3 XA 575 [2611 39 1990,61 20 [5081 135 [611 121 [551 151 (691 168 [761 6. SIDE DUCT FLANGES ARE 0.815' [22.2] HIGH. [45,8) BOTTOM DUCTS DO NOT HAVE FLANGES. [699,6] 4 XA 585 [2651 39 [990,6) 20 15081 137 [621 121 [561 154 [101 171 [181 7. MINIMUM CONDENSATION TRAP HEIGHT SHALL BE 1.5 TIMES + REAR THE LOWEST NEGATIVE STATIC. 5 XA 590 [2681 39 [990,61 20 [5081 138 [631 125 1511 155 [701 172 [781 8. DIMENSIONS IN [ ] ARE IN MILLIMETERS OR KILOGRAMS. 9. OPTIONAL COIL GUARD, GAS HEAT, ECONOMIZER HOOD, DISCONNECT SWITCH, CONVENIENCE OUTLET, AND 5.51 OUTLET/INLET HOOD SHOWN. (140,01 i A + - 5.89 [149,61 B ® EXCEPT XA (HEAT PUMP) UNITS. Rs----�-`-� ` i .- - � DIRECTION OF AIRFLOW POWER WIRING BOTTOM ENTRY f 12.26 i x (311,3] r N s u 11.50 [292,1] ; �/ rrd"E�"'. I l [toxo / 0/A 3.00 II. 0 [76.2) [292,1) 952.00 [50,81 f ---I 17.50 � L''. ),50 CENTER OF GRAVITY 4.00 - ` ?tJ FIGHT Il AETUNN / 11.50 19.08 [101,6]_=_£��`� �[4d4,5] \ -s`= Il III Ill SUPPLY 0/A y [292,1] [184,6] 1 8.23 [209,21 I 6.50 } L 4.58 0 [165,11 17.50 7.62 [(16,31 I 11.06 6.18 [144,5] [193,6) [281,0] [164,7] AS SUPPLY BOTTOM ENTRY 951.50 (38,11 N.O. 17.50 31.62 CONTROL WIRING BOTTOM ENTRY 00.88 [22,2] 32.09 [815,21 (0.50 [12,1] NPT AT GAS VALVE VENT AIR OUTLET HOOD ® [444,5] REAR [803,2] PARTIAL VIEW)(RAIN ECONOMIZER HOOD 951.97 N.O. (OPTIONAL) [50,0] DISCONNECT SWITCH COVER (OPTIONAL) X OMBUSTION A R INLET HOOD + HOOD NOT SHOWN IN THIS VIEW) • - ACCESS ^ FAT Iii CORP. j I 111110, BLOWER CONVENIENCE OUTLET ACCESS ACCESS I ij ACCESS COVER )OPTIONAL) � ACCESS ° t 32.55 L I I [69457] illi Pk 0[22821 N.O.i��u�����>v I ■�[826,71 i it .. 3._ tri 3.78 (96,0) 4.38 6.94 [111,11 [176,2] 14.88 \ 18.58 (411,91 0.75 [19,1] 19.67 [499,7) 4.42 [112.31 - 31.89 AS SUPPLY ENTRY [810,01 V51.63 [41,41 ® [1139,81 OIL GUARD (OPTIONAL) FXGHT VIEW 2.55 - 82.19 PVC FPT [64,1] [2087,61 COND. DRAIN FRONT VIEW LEFT VIEW Information is subject to change without notice. Check local codes. Printed 10/28/2013 Coleman@ HEATING A AIR CONDMONING 3-6 Ton Package Single Package R -410A Air Conditioner Page: 6 Project Name: All Hi -Tech Unit Model #: ZS-04NO7AFAAA2 Quantity: 1 System: ZS-04NO7AFAAA2 ((e)) DCL Seismic Certification SPECIAL SEISMIC CERTIFICATION OF NON-STRUCTURAL COMPONENTS AND SYSTEMS CERTIFICATE OF COMPLIANCE Johnson iyd Controls Dynamic Certification Laboratories has qualified the listed packaged rooftop units as CERTIFIED for seismic applications in accordance with the following codes and standards: CBC 2010, IBC 2009, ICC -ES AC -156 2010, ASCE 7-05 The following model designations are included in this certification. A complete list of certified models, options, and installation methods are detailed in report number 90300-1108a by Dynamic Certification Laboratories, provided by the equipment manufacturer upon request. Unitary Product Group Packaged Rooftop Units (UPG) Seismic Qualification Testing was conducted in accordance with and in strict adherence to the standards set forth within the American Society of Civil Engineers (ASCE 7) by the independent approval agency, Dynamic Certification Laboratories. The above referenced equipment is APPROVED for seismic applications when properly installed and used as intended. The basis of this certification is through testing of the active and energized components per AC156. This certification covers multiple UPG brands, including York, Johnson Controls, Coleman, Luxaire, Evcon and Fraser - Johnston. The seismic values are obtained from the Maximum Considered Earthquake Short Period Spectral Response Acceleration, Sds, as determined by the ASCE 7 seismic maps. Various installation locations/isolation configurations are covered under this certification, limited by the Sds value stated in the following table. A seismic importance factor, Ip, of 1.5 applies to this certification to include essential facility requirements and life safety applications for post event functionality. The units are approved for both a rigid and flexible mount configuration. Maximum Design Sds Values of UPG Packaged Rooftop Units Series Model Tons Sds (g) Fp/Wp XP/XA/J0*XP/T0* 036, 048, 060 3, 4, 5 2.5 1.88 ZF/ZS/J0*ZF/JA*ZF/T0* 036, 048, 060, 072 3, 4, 5, 6 2.5 1.88 ZR/ZK/10*ZR/T0* 036, 048, 060 3, 4, 5 2.5 1.88 Page].of2 Dynamic Certification Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431 —ph: 775-358-5085 www.shaketest.com Unitary Sales Tool v1.5.7.30 Information is subject to change without notice. Check local codes. Printed 10Q8/2013 1C%mon@ HEATING 8 AIR CONDITIONING 3-6 Ton Package Single Package R -410A Air Conditioner Page: 7 Project Name: All HI -Tech Unit Model #: ZS-04NO7AFAAA2 Quantity: 1 System: ZS-04NO7AFAAA2 Seismic Certification SPECIAL SEISMIC CERTIFICATION OF NON-STRUCTURAL COMPONENTS AND SYSTEMS CERTIFICATE OF COMPLIANCE Johnson 4,.P Controls Table of Seismic Des gn Parameters Site Class F. I, ap Rp z/h D 1.0 1.5 2.5 6.0 1.0 Site and Project Requirements It is the responsibility of the Design Professional of Record to: • Provide engineering for the anchorage and restraint of the unit • Validate Cerftficafton Design Parameters with actual site condiftons • Provide engineering of all equipment support structures • Confirm component configurafton Cerftficafton Issued by: Dynamic Cerftficafton Laboratories Document Control Number: 90300-1108a-1 Issue Date: 12/19/11 Dr. Ahmad Itani, SE Dynamic Cerftficafton Laboratories i“ (5ef Randy Forristall YORK Unitary Engineering Johnson Controls, Incorporated Page 2 of 2 Dynamic Cerftficafton Laboratories 1315 Greg Street, Suite 109, Sparks, NV 89431— ph: 775-358-5085 www.shaketest.com Unitary Sales Tool v1.5.7.30 Information is subject to change without notice. Check local codes. Printed 1028/2013 Date 10/28/2013 Project Name All Hi -Tech Project Number Client / Purchaser Guide Specification Summary Page HEATING & AIR CONDITIONING Product Series Models and Unit Tags 3 6 TonPackage .',4S-04N07AFAAA2 Unitary Sales Tool v1.5.7.30 Information is subject to change without notice. Check local codes. Printed 10128/2013 HEATING & AIR CONDITIONING Guide Specification for Apex 3-6 Ton Single Package Page: 9 GENERAL Units shall be manufactured by Johnson Controls Unitary Products in an ISO 9001 certified facility. Coleman 3-6 Ton package units are convertible single package units. Although the units are primarily designed for curb mounting on a roof, they can also be slab -mounted at ground level or set on steel beams above a finished roof. Cooling only, cooling with gas heat and cooling with electric heat models are available with a wide variety of factory -mounted options and field -installed accessories to make them suitable for almost every application. All units are self-contained and assembled on full perimeter base rails with holes in the four corners for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to simplify the field installation and to provide years of dependable operation. All models (including those with an economizer) are suitable for either bottom or horizontal duct connections. Models with power exhaust are suitable for bottom duct connections only. For bottom duct, remove the sheet metal panels from the supply and return air openings through the base of the unit. For horizontal duct, remove the supply and return air panels on the rear of the unit. All non -Scroll compressors include crankcase heaters and all compressors have internal pressure relief. Every refrigerant circuit includes a liquid line filter -drier, a discharge line high pressure switch and a suction line with a freezestat and low pressure/loss of charge switch. The unit control circuit includes a 75 VA transformer, a 24 -volt circuit breaker and a relay board with a compressor lockout circuit, a terminal strip for thermostat wiring, plus an additional set of pin connectors to simplify the interface of additional field controls. All models are CSA listed. All models include a 1 -year limited warranty on the complete unit. Compressors and electric heater elements carry a 5 - year warranty. Aluminized steel and Stainless steel tubular heat exchangers carry a 10 -year warranty. DESCRIPTION Units shall be factory -assembled, single packaged, Electric Cooling/Gas Heat, Electric Cooling/Optional Electric Heat, Heat Pump/Optional Electric Heat are designed for outdoor mounted installation. The 3 ton, 4 ton and 5 ton units shall have minimum SEER rating of 13.0 with heat pumps having a 7.7 H.S.P.F. The 6 Ton Cooling only or Cooling with Electric Heat shall have 11.2 EER, 6 Ton Cooling with Gas Heat shall have 11.0 EER. They shall have built-in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R -410A refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. All units the cooling performance shall be rated in accordance with DOE and AHRI test procedures. Units shall be CSA listed, classified to ANSI Z21.47, UL 1995/CSA No. 236 standards. UNIT CABINET Unit cabinet shall be constructed of galvanized steel, with exterior surfaces coated with a non -chalking, powdered paint finish, certified at 1000 hours salt spray test per ASTMB117 standards. Indoor blower section shall be insulated with a minimum 1/2" thick insulation, coated on the airside. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. Cabinet panels shall be "large" size, easily removable for servicing and maintenance. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging and proper sealing on roof curb applications. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed airtight. Units filter track shall be designed to accommodate either 1" or 2" filters. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air by-pass of the coils. Condensate pan shall be internally sloped and conform to ASHRAE 62-89 self -draining standards. Condensate connection shall be a minimum of 3/4" I.D. female and be a ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY The indoor fan shall be a factory installed direct -drive or belt -drive assembly that includes an adjustable pitch motor pulley. Job site selected (B.H.P.) brake horsepower shall not exceed the motors nameplate horsepower rating, plus the service factor. Units shall be designed not to operate above service factor. Fan wheel shall be double -inlet type with forward -curved blades, dynamically balanced to operate smoothly throughout the entire range of operation. Airflow design shall be constant air volume. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. OUTDOOR (CONDENSER) FAN ASSEMBLY The outdoor fan shall be of the direct -driven propeller type, discharge air vertically, have aluminum blades riveted to a corrosion resistant steel spider bracket and shall be dynamically balanced for smooth operation. The outdoor fan motor shall be totally enclosed with permanently lubricated bearings, internally protected against overload conditions and staged independently. Unitary Sales Tool v1.5.7.30 Information is subject to change without notice. Check local codes. Printed 10/28/2013 HEATING A AIR CONDITIONING Guide Specification for Apex 3-6 Ton Single Package Page: 10 REFRIGERANT COMPONENTS Compressors: a. Shall be internally protected with internal high- pressure relief and over temperature protection. b. Shall have internal spring isolation and sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, independent mounting. Coils: a. Evaporator coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. b. Evaporator coils shall be of the direct expansion, draw-thru design. c. Condenser coils shall have aluminum plate fins mechanically bonded to seamless internally enhanced copper tubes with all joints brazed or Micro -Channel aluminum tube, aluminum fins. d. Condenser coils shall be of the direct expansion, draw-thru design. Refrigerant Circuit and Refrigerant Safety Components shall include: a. Independent fixed -orifice or thermally operated expansion devices. b. Filter drier/strainer to eliminate any moisture or foreign matter. c. Accessible service gage connections on both suction and liquid lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. d. The refrigeration system shall provide at least 15°F of sub -cooling at design conditions. Unit Controls: a. Unit shall be complete with self-contained low -voltage control circuit protected by a resettable circuit breaker on the 24 -volt transformer side. b. Unit shall incorporate a lockout circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor. c. Loss-of-charge/Low-pressure switch. d. High-pressure switch. e. Freeze -protection thermostat, evaporator coil. f. Unit shall incorporate "AUTO RESET" compressor over temperature, over current protection. g. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. h. Unit control board shall have on -board diagnostics and fault code display. i. Standard controls shall include anti -short cycle and low voltage protection, and permit cooling operation down to 0°F. Control board shall monitor each refrigerant safety switch independently. k. Control board shall retain last 5 fault codes in non volatile memory which will not be lost in the event of a power loss. J. GAS HEATING SECTION (SINGLE STAGE) Shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition, and redundant main gas valve. Venter wheel shall be constructed of stainless steel for corrosion resistance. The heat exchanger shall be of the tubular type, constructed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25°F. Burners shall be of the inshot type, constructed of aluminum coated steel and contain air mixture adjustments. All gas piping shall enter the unit cabinet at a single location through either the side or curb without any field modifications. Integrated control boards shall provide timed control of evaporator fan functioning and burner ignition. Heating section shall be provided with the following minimum protection. a. Primary and auxiliary high-temperature limit switches. b. Induced draft motor speed sensor. c. Flame roll out switch. d. Flame proving controls. e. If any of the above safety devices trip, a LED (light - emitting diode) indicator shall flash a diagnostic code that indicates which safety switch has tripped. NOTE: All 2 Stage Gas Heat, 60% Capacity 1st Stage, 40% Capacity 2nd Stage. UNIT OPERATING CHARACTERISTICS Unit shall be capable of starting and running at 125°F outdoor temperature, exceeding maximum load criteria of AHRI Standard 210/240. The compressor, with standard controls, shall be capable of operation down to 0°F outdoor temperature. Unit shall be provided with fan time delay to prevent cold air delivery before heat exchanger warms up (Gas heat only). Unitary Sales Tool v1.5.7.30 Information is subject to change without notice. Check local codes. Printed 10/28/2013 HEATING & AIR CONDITIONING Guide Specification for Apex 3-6 Ton Single Package Page: 11 ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES • Compressor 5 Years • Heat Exchanger 10 Years • Electric Heat Element 5 Years • Other Parts 1 Year ADDITIONAL FACTORY INSTALLED OPTIONS FIELD INSTALLED OPTIONS • Single Input Electronic Enthalpy Economizer — Includes a slide -in / plug-in damper assembly with fully modulating spring -return motor actuator capable of introducing up to 100% outdoor air with nominal 1% leakage type dampers. The enthalpy system contains one sensor that monitors the outdoor air and determines when the air is cool enough and dry enough to provide free cooling. The rain hood is painted to match the basic unit and must be field - assembled before installing. • Barometric Relief Damper — This damper accessory can be used to relieve internal building air pressure on units with an economizer without power exhaust. This accessory includes a rain hood, a bird screen and a fully assembled damper. With bottom duct connections, the damper should be mounted over the opening in the return air panel. With horizontal ductwork, the accessory should be mounted on the return air duct. Unitary Sales Tool v1.5.7.30 Information is subject to change without notice. Check local codes. Printed 10/28/2013 FILE C DESCRIPTION DCG MODEL SHOWN YORK Sunline 2000 units are convertible single package air conditioners with a common cabinet and a common roof curb for the 3, 4, 5 and 6 ton sizes. The units were designed for light commercial and commercial applications. They can easily be installed on a roof curb, slab, roof jack or frame. All units are self-contained and assembled on rigid full perimeter base rails with fork lift slots on three sides and holes for overhead rigging. Every unit is completely piped, wired, charged and tested at the factory to provide for a quick and easy field installation. The units are available in cooling only, and cooling with gas heat. Electric heaters are available as field -installed accessories. The cabinet is constructed of galvanized steel, painted with long lasting, durable, and aesthetically pleasing power paint. Paint finish meets 750 hour salt spray tests per ASTM -B117 standards. All models include a 5 -year limited warranty on scroll compressors and electric heating elements, a 10 -year limited warranty on gas-fired heat exchangers and a 1 -year limited warranty on all replacement parts. FEATURES COMMON FOOTPRINT/COMMON CABINET - All model sizes and configurations share a common cabinet and a common roof curb. The installer has the flexibility of setting one curb and placing the proper tonnage unit on that curb after the internal load has been determined. He can even decide between gas or electric heat after the curb has been set HIGH EFFICIENCY - All units have a high cooling efficiency, and gas / electric models have a minimum AFUE of 80%. All efficiencies exceed legislated minimum levels and provide low operating costs. CONVERTIBLE AIRFLOW DESIGN - Both the side and bottom duct openings are covered when they leave the factory. If a side supply / side return is desired, you simply remove the two side duct covers from the outside of the unit and discard them. If a bottom supply / bottom return is desired, you simply remove the U k' 530.18-TG1Y (500) 12YORIC SINGLE PACKAGE AIR-COOLED AIR CONDITIONERS D4CE 036, 048, 060 & D2CE 072 D7CG 036, 048, 060 & D2CG 072 3, 4 AND 5 NOMINAL TONS (10 SEER) AND 6 NOMINAL TONS (9 EER) SUNLINE 2000TCIYY OF TUKW ILA NOV 1:2 2013 PERMIT CENTER two knockout panels from the base of the unit and discard them. No panel cutting or swapping is required! Convertible airflow design allows maximum field flexibility and minimum inventory. Economizers may be used on either bottom and side duct applications with no modifications required. FACTORY -INSTALLED OPTIONS - Economizers can be installed at the factory. The economizers are shipped installed and wired. Only the rain hood needs to be field assembled and installed. Field labor dollars can be saved by having the components arrive already installed. Adjustable belt drive blowers are available on all models from the factory for complete airflow flexibility. FIELD -INSTALLED ACCESSORIES - Accessories were designed for quick and easy installation. The motorized damper and economizers simply slide in, and electrical connections are made by modular plugs. Electric heaters mount easily, and knockouts are provided in the internal partitions to connect the elements to the control box single point kit. The motorized air damper includes a slid-in/plug-in damper assembly with a rainhood and filters. The outdoor air dampers open when the indoor fan motor is energized. The damper is capable of providing 0% through 100% of outdoor return air opening. The manual outdoor damper provides 0% through 35% or 0% through 100% of return air opening (field adjustable). Designed for duct mounted side or bottom supply/return applications. Includes rain hood assembly and filter. The 14" high roof curb is shipped knocked down. An insulated deck is not required because the bottom of the unit is insulated. Low ambient controls are available to provide stable unit operation at outdoor temperatures down to 0°F. Propane, high altitude and low NOx kits are also available to cover all gas heating applications. WIDE RANGE OF INDOOR AIRFLOWS - All 3, 4 and 5 -ton models operate over a wide range of design conditions with a Cont'd. 530.18 -TG I Y FEATURES - CONT'D. 3 -speed direct -drive fan motor. The 6 -ton unit has a single speed direct -drive fan motor. Belt -drive blowers are also available on all 3, 4, 5 and 6 -ton models. FULL PERIMETER BASE RAILS - The permanently attached base rails provide a solid foundation for the entire unit and protect the unit during shipment. The rails provide fork lift access from 3 sides, and rigging holes are also provided so that an overhead crane can be used to place the units on a roof. SYSTEM PROTECTION - Internal overload protection are standard on all scroll compressors. Every unit has a liquid line filter -drier, high and low pressure/lose at charge switches and a suction line freezestat to protect all system components. All units will provide cooling at ambient temperatures down to 45°F UTILITY CONNECTIONS MADE EASY - Gas and electric utility knockouts are provided in the unit base as well as the side of the unit. A clearly identified location is provided to mount a field supplied electrical disconnect switch. Utility connections can be made quickly and with a minimum amount of field labor. SIMPLE CONTROL CIRCUIT - A low voltage printed circuit board contains a scroll compressor lockout indicator light and a low voltage terminal strip. An additional set of pin connectors is also provided to simplify the field interface of external controls. Mate -n -lock plug connectors are used where line and low voltage wires pass thru internal bulkheads. This allows for easier troubleshooting and component replacement. The electrical control box is not located in the scroll compressor compartment so the access cover can be removed for troubleshooting without affecting the normal system operating pressures. All wiring internal to the unit is color/number coded. AIR FILTERS - Units are shipped with 1" disposable filters. The unit filter racks can accommodate 1" or 2" filters without any modifications. YORK' SUNLINE 2000TM LOW VOLTAGE RELAY BOARD 20 GAUGE ALUM NIZED STEEL AND TERMINAL STRIP TUBULAR HEAT EXCHANGER ELECTRICAL DISCONNECT MOUNTING LOCATION (Field Installed) ECONOMIZER HOOD DIRECT DRIVE BLOWER MOTOR (Belt Drive Option also available on some models) ELECTRIC HEAT ACCESSORY LOCATION (Elec/Elec Units) POWER VENTER MOTOR OUTDOOR AIR OPENING FOR SLIDE-IN/PLUG IN INTERNAL ECONOMIZER (ACCESSORY) SIDE RETURN AIR DUCT OPENING (Return Air & Supply Air Side by Side) BOTTOM RETURN AIR DUCT OPENING (Return Air & Supply Air Side by Side) 3/4" PVC FEMALE CONDENSATE DRAIN KNOCKOUTS FOR SIDE POWER AND CONTROL ENTRY TERMINAL BLOCK (For Single Point Power Supply on Elec/Elec Units) KNOCKOUT FOR BOTTOM GAS SUPPLY ENTRY KNOCKOUT FOR BOTTOM POWER ENTRY COPPER TUBE / ALUMINUM FIN CONDENSER COIL HIGH EFFICIENCY SCROLL COMPRESSORS BASE RAILS WITH FORKLIFT SLOTS AND LIFTING HOLES KNOCKOUT FOR SIDE GAS SUPPLY ENTRY MODEL DCG (Gas Heating) TABLE OF CONTENTS Description Features 1 Ratings 3 Sound Power Ratings for Supply Air Blower 3 Physical Data 3 Cooling Capacities - 3 Ton 4 Cooling Capacities - 4 Ton 5 Cooling Capacities - 5 Ton 6 Cooling Capacities - 6 Ton 7 Blower Performance - 3 & 4 Ton w/Belt-Drive 8 Blower Performance - 5 & 6 Ton w/Belt-Drive 9 Blower Performance - 3 - 6 Ton w/Direct-Drive 10 Option and Accessories 10 1 Static Resistances 11 Motor and Drive Data 11 Electrical Data - Basic Units 11 Elec. Data-Clg./Elec. Htg. Elec. Data-Clg./Elec. Htg. Elec. Data-Clg./Elec. Htg. Elec. Data-Clg./Elec. Htg. Field Wiring Unit Dimensions Roof Curb Dimensions 3 & 4 Ton w/Direct-Drive 12 5 & 6 w/Direct-Drive 13 3 & 4 w/Belt-Drive 14 5 & 6 w/Belt-Drive 15 16 17 & 18 19 Component Weights and Center of Gravity 19 Typical Applications 20 Mechanical Specifications 21 2 Unitary Products Group RATINGS CAPACITY RATINGS - Cooling / Electric Heatin MODEL ARI RATINGS' NOMINAL ELECTRIC HEAT CAPACITY3 (KV STANDARD CFM COOLING CAPACITY 80 / 67-95°F SOUND RATING2 (dbels) MBH SEER EER 240V 480V 600V DCE036 36.0 10.00 9.10 82 5 7, 10, 15&20 7, 10, 15&20 10, 15&20 1.300 DCE048 47.4 10.00 9.00 82 5 7, 10, 15&20 7, 10, 15&20 10, 15&20 1.700 DCE060 59.0 10.00 9.10 82 5, 7, 10, 15,20 &30 7, 10, 15 20 & 30 10, 15, 20 &30 2.100 DCE072 72.0 - 9.00 84 5, 7, 10, 15,20 &30 7, 10, 15, 20 &30 10, 15, 20 &30 2.400 CAPACITY RATINGS - Cooling / Gas Heating 530.18 -TG 1 Y - Not ARI Usted. MODEL ARI RATINGS1 GAS HEAT CAPACITY STANDARD CFM COOLING CAPACITY 80 / 67-95°F SOUND RATING2 (dbels) INPUT (MBH) (MBH) AFUE (%) •OUTPUT S.S.E. (%) TEMP. RISE (°F) GAS LE MBH SEER EER DCG036N040 DCG036N079 36.0 36.0 10.00 10.00 9.10 9.10 82 82 50 100 40 79 80.9 80.5 81.6 80.8 15-45 40-70 1/2 1/2 1.300 DCG048N060 DCG048N099 47.4 47.4 10.00 10.00 9.00 9.00 82 82 75 125 59 99 80.9 80.3 81.6 80.6 25-55 45-75 1/2 1/2 1.700 DCGO6ON079 DCGO6ON099 59.0 59.0 10.00 10.00 9.10 9.10 82 82 100 125 79 99 80.5 80.3 80.8 80.6 25-55 35-65 1 1/2 2.100 DCG072N079 72.0° -9.00 2,000 84 100 79 80.5 80.8 25-55 1/2 71 DCG072N099 72.0° - 9.00 84 125 99 80.3 80.6 35-65 1/22.400 87 'Certified h accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240. 'Rated in accordance with ARI Standard 270. 'Heaters are available as accessories - a0 with single point power supply...Certified in accordance with the Unitary Large Equipment certification program, which is based on ARI Standard 340/360. SEER - Seasonal Energy Efficiency Ratio - the total cooling output in BTU's during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period. EER - Energy Efficiency Ratio - the cooling capacity in Btu's per hour (Stull) divided by the power input in watts at any given set of rating conditions, expressed in BTUH per watt (BTUH/watt). AFUE - Annual Fuel Utilization Efficiency - determined in accordance with DOE test procedure. S.S.E. - Steady State Efficiency. (Percent Output). SOUND PQWER RATINGS FOR SUPPLY AIR BLOWER MODEL CFM ESP BLOWER SOUND POWER (dB 10-12 watts) OCTAVE BAND CENTERLINE FREQUENCY (Hz) SIM_dB dB (A) (A) 1 IWG SPEED KW 63 125 250 500 1,000 2,000 4,000 8,000 036 1,200 0.60 LOW 0.60 84 84 74 67 69 62 57 52 74 41 048 1,600 0.55 HIGH 0.80 85 85 75 68 70 63 58 53 75 42 060 2,000 0.45 HIGH 1.00 86 86 76 69 71 64 59 54 76 43 072 2,200 0.30 HIGH 1.35 87 87 77 70 72 65 60 55 77 44 At a distance of 10 ft.from the blower. NOTE: These values have been derived using a model of sound propagation, measuring the indoor ambient sound evels ten feet from the source. The dBA values provided are for reference only. Calculation of dBA values cover matters of system design and application. This constitutes an exception to any specification or guarantee requiring a CBA value or sound data in any other form than sound power level ratings. PHYSICAL DATA - BASIC UNITS MODEL EVAPORATOR BLOWER EVAPORATOR COIL COMPRESSOR TYPE CONDENSER FAN CONDENSER COIL AIR FILTERS (SEE NOTE) CHARGE CENTRIFUGAL (Dia. x Wd. in.) FAN MOTOR HP (DIRECT -DRIVE) FAN MOTOR HP (BELT -DRIVE) ROWS DEEP FINS PER INCH FACE AREA (Sq. Ft.) HERMETICALLY SEALED PROPELLER DIA. (in.) FAN MOTOR HP NOM. CFM TOTAL ROWS DEEP FINS PER INCH FACE AREA (Sq. Ft.) QUANTITY PER UNIT (15" X 20" X 1") QUANTITY PER UNIT (14" X 25" X 1") TOTAL FACE _AREA (sq. ft.) REFRIGERANT R-22 (lbs./oz.) 036 12 x 10 1/2 11/2 3 13 3.6 SCROLL TYPE 24 1/4 3,400 1 16 17.1 2 1 6.3 5/8 048 12 x 10 3/4 11/2 3 13 4.3 24 1/4 3,400 1 16 17.1 2 1 6.3 6/8 060 12 x 10 1 11/2 3 13 5.1 24 1/4 3,400 1 22 17.1 2 1 6.3 6/8 072 12 x 11 1 11/2 4 13 5.1 24 1/4 3,300 2 16 16.7 2 1 6.3 10/0 NOTE: Filter racks are adapted for 1" or 2" thick fliers. Unitary Products Group 3 530.1,8-TGfY COOLING CAPACITIES - 3 TON (DCE / DCG036) Air On Evaporator Coil Temperature of Air on Condenser Coil 85°F 95°F Total Cap.1 MBH Powe[ Input` KW Sensible Capacityl, MBH Total Cap.1 MBH Powe Input' KW Sensible Capac'ty1, MBH CFM WB °F Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 45 3.1 35 30 26 21 17 - - 43 3.3 35 30 26 21 17 - - 1750 67 43 3.0 43 38 34 29. 25 20 16 41 3.3 41 38 34 29 25 21 16 62 39 3.0 39 39 39 34 30 25 21 36 3.3 36 36 36 32 27 23 18 57 40 2.9 40 40 40 35 31 26 22 38 3.2 38 38 38 33 29 24 20 72 44 3.1 31 28 24 20 16 - - 42 3.3 31 27 23 20 16 - - 1475 67 41 3.0 39 35 31 27 23 19 16 39 3.3 37 35 31 27 23 19 15 62 38 3.0 38 38 37 33 29 25 21 36 3.3 36 36 35 31 27 23 19 57 39 2.9 39 39 39 35 31 27 23 37 3.2 37 37 36 32 28 25 21 72 _ 42 3.1 28 25 22 18 15 - - 41 3.3_ 28 24 21 18 14 - - 1200 -67 . 40 3.0 35 32 28 25 22 18 15 98_._ 3.2 34 31 28.. 25 21 18 15 62 36 3.0 36 36 35 31 28 25 21 35 3.3 35 35 34 30 27 24 20 57 37 2.9 37 37 37 34 31 27 24 36 3.2 36 36 35 32 28 25 22 72 41 3.1 26 23 20 17 14 - - 39 3.2 26 23 20 17 14 - - 1050 67 38 3.0 32 30 27 24 21 18 15 37 3.2 32 29 26 23 20 17 14 62 35 3.0 35 35 33 30 27 24 21 33 3.2 33 33 31 28 25 22 20 57 36 2.9 36 36 35 32 29 26 23 34 3.2 34 34 32 30 27 24 21 72 39 3.1 24 21 19 16 14 - - 38 3.2 23 21 18 16 13 - - 900 67 37 3.0 30 27 25 22 20 17 15 36 3.2 29 26 24 21 19 16 14 62 34 3.0 34 33 30 28 25 23 20 32 3.2 32 31 29 26 24 21 19 57 34 2.9 34 34 33 30 27 25 22 33 3.1 33 33 30 27 25 22 20 Air On Evaporator Coil Temperature of Air on Condenser Coil 105°F 115°F Total Powe Input KW Sensible Capac'ty1, MBH Total Cap.1 MBH Powe Input' KW Sensible Capactyl, MBH CFM WB °F Cap.1 MBH Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 41 3.7 34 29 25 20 16 - - 39 4.1 33 28 24 19 15 - - 1750 67 38 3.7 38 37 33 28 24 19 15 36 4.0 36 36 32 27 23 18 14 62 34 3.7 34 34 34 30 25 21 16 32 4.0 32 32 32 27 23 18 14 57 35 3.6 35 35 35 31 26 22 17 33 4.0 33 33 33 28 24 19 15 72 40 3.7 30 26 23 19 15 - - 38 4.1 30 26 22 18 14 - - 1475 67 37 3.6 36 34 30 26 22 18 14 35 4.0 34 33 29 25 21 17 13 62 33 3.7 33 33 33 29 25 21 17 31 4.0 31 31 31 27 23 19 15 57 34 3.6 34 34 34 30 26 22 18 32 4.0 32 32 32 28 24 20 16 72 39 3.7 27 24 20 17 14 - - 37 4.1 26 23 20 16 13 - - 1200 67 36 3.6 34 30 27 24 20 17 14 34 4.0 33 30 26 23 20 16 13 62 32 3.6 32 32 32 29 25 22 19 30 4.0 30 30 30 27 24 20 17 57 33 3.6 33 33 33 29 26 23 19 31 3.9 31 31 31 27 24 21 17 72 37 3.6 25 22 19 16 13 - - 36 4.1 24 21 18 15 12 - - 1050 67 35 3.6 31 28 25 22 19 16 13 32 4.0 30 27 24 21 18 15 12 62 31 3.6 31 31 29 27 24 21 18 29 4.0 29 29 28 25 22 19 16 57 32 3.5 32 32 30 27 24 21 18 30 3.9 30 29 28 25 22 19 16 72 36 3.6 22 20 17 15 12 - - 34 4.0 21 19 16 14 11 - - 900 67 33 3.6 28 25 23 20 18 15 13 31 4.0 27 24 22 19 17 14 11 62 30 3.6 30 29 27 24 22 19 17 28 4.0 28 28 25 22 20 17 15 57 31 3.5 31 30 28 25 22 20 17 28 3.9 28 28 25 23 20 17 15 I These capacities are gross ratings. For net capacity, determine the KW of the supply air dower moto from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat and deduct this heat from the gross capacity of the unit. 2 These ratings include the compressor and the condenser fan motors but not the supply air dower motor. The total condenser fan motor power input is 0.36 KW Refer to the Blower Performance Table for the KW of the supply air blower motor. NOMINAL RATING 4 ALL SENSIBLE CAPACITY Unitary Products Group 530.18 -TG 1 Y COOLING CAPACITIES - 4 TON (DCE / DCG048) Air On Evaporator Coil Temperature of Air on Condenser Coil 85°F 95°F Total Cap.1 Powe Input Sensible Capac'ty1, MBH Total Cap.1 Powe Input Sensible Capacityl, MBH CFM WB Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 °F MBH KW MBH KW 31 72 60 4.1 44 39 33 28 23 - - 60 4.5 44 _ 39 33 28 23 - - 2000 67 55 4.1 53 48 42 37 32 26 21 52 4.5 52 47 42 36 31 25 20 45 62 51 4.0 51 51 51 45 40 34 29 48 4.4 48 48 48 42 37 32 26 44 57 49 3.9 49 49 49 44 39 33 28 47 4.3 47 47 47 42 36 31 26 29 72 58 4.1 41 36 31 26 21 - - 57 4.5 41 36 31 26 21 - - 1800 67 53 4.1 49 45 40 35 30 25 20 50 4.5 49 44 39 34 29 24 19 43 62 49 4.0 49 49 48 43 38 33 28 46 4.4 46 46 46 41 36 31 26 43 57 47 3.9 47 47 47 43 38 33 28 45 4.3 45 45 45 40 36 31 26 28 72 _ 56 4.1 38 34 29 25 20 - - 55 4.6 38 33 29 24 20 - - 35 67 51 4.1 46 41 37 32 28 24 19 48 4.5 45 40 36 31 27 23 18 1600 37 33 28 24 39 5.3 39 39 39 35 30 26 21 57 41 4.8 41 41 41 62 47 4.0 47 47 45 41 36 32 27 44 4.4 44 44 44 40 35 31 26 26 57 46 3.9 46 46 46 41 37 32 28 44 4.4 44 44 44 39 35 30 26 33 72 54 4.1 35 31 27 23 19 - - 53 4.5 35 31 27 23 19 - - 1400 67 49 4.1 42 38 34 30 26 22 19 47 4.5 41 38 34 30 26 22 18 38 62 45 4.0 45 45 42 38 34 30 26 43 4.4 43 43 41 37 33 29 25 23 57 44 3.9 44 44 43 39 35 31 27 42 4.3 42 42 41 37 33 29 25 30 72 52 4.1 32 29 25 22 18 - - 51 4.5 32 28 25 21 18 - - 1200 67 47 4.1 39 35 32 28 25 21 18 45 4.4 38 35 31 28 24 21 17 35 62 43 4.0 43 43 39 36 32 29 25 41 4.3 41 41 38 35 31 28 24 57 42 3.9 42 42 39 36 _ 32 29 25 41 4.3 41 41 38 34 31 27 24 Air On Evaporator Coil Temperature of Air on Condenser Coil 105°F 115°F Total Cap.1 MBH Powe Input KW Sensible Capac'ty1, MBH Total Cap.1 MBH Powe Input KW Sensible Capacityl, MBH CFM WB °F Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 56 5.1 42 37 31 26 21 - - 53 5.6 40 35 29 24 19 - - 2000 67 49 5.0 49 46 40 35 29 24 19 46 5.5 46 44 39 33 28 23 17 62 45 4.9 45 45 45 39 34 28 23 41 5.4 41 41 41 36 30 25 20 57 44 4.9 44 44 44 39 33 28 22 41 5.4 41 41 41 35 30 25 19 72 55 5.0 39 34 29 24 20 - - 52 5.5 38 33 28 23 18 - - 1800 67 48 5.0 47 43 38 33 28 23 18 45 5.4 45 42 37 32 27 22 17 62 43 4.9 43 43 43 38 33 28 23 40 5.4 40 40 40 35 30 26 21 57 43 4.9 43 43 43 38 33 28 23 40 5.4 40 40 40 35 30 25 20 72 53 5.0 36 32 28 23 19 - - 51 5.5 35 31 26 22 17 - - 1600 67 46 4.9 44 40 35 31 26 22 17 44 5.4 44 39 35 30 26 21 17 62 42 4.9 42 42 42 37 33 28 24 39 5.3 39 39 39 35 30 26 21 57 41 4.8 41 41 41 37 32 28 23 39 5.3 39 39 39 34 30 25 21 72 51 5.0 33 29 26 22 18 - - 48 5.5 32 28 24 20 16 - - 1400 67 44 4.9 41 37 33 29 25 21 17 42 5.3 40 36 32 28 24 20 16 62 40 4.8 40 40 39 35 31 27 23 37 5.3 37 37 36 32 28 24 20 57 40 4.8 40 40 38 34 30 26 22 37 5.3 37 37 36 32 28 24 20 72 49 4.9 30 27 23 20 16 - - 46 5.4 29 26 22 19 15 - - 1200 67 42 4.9 37 34 30 27 23 20 16 39 5.3 36 33 29 26 22 19 15 62 38 4.8 38 38 36 32 29 25 22 35 5.3 35 35 33 29 26 22 19 57 38 4.8 38 38 35 32 28 25 21 35 5.3 35 35 33 29 26 22 19 I These capacities are gross ratings. For net capacity, determine the KW of the suppy air Dower moto from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2 These ratings include the compressor and the condenser fan motors but not the supply air blower motor. The total condenser fan motor power input is 0.36 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. NOMINAL RATING Unitary Products Group ALL SENSIBLE CAPACITY 5 530.1d8-TGiY COOLING CAPACITIES - 5 TON (DCE / DCG060) Air On Evaporator Coil Temperature of Air on Condenser Coil 85°F 95°F Total Cap.1 MBH Powe Input KW Sensible Capacityl, MBH Total Cap.1 MBH Powe Input KW Sensible Capacityl, MBH CFM B °F Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68I 86 . 83 8Q 77 74 71 68 72 68 4.9 50 44 38 32 25 - - 65 5.6 50 43 37 31 24 - - 2500 67 62 4.8 62 56 50 43 37 31 24 60 5.3 60 54 48 42 35 29 23 62 57 4.7 57 57 57 51 44 38 32 53 5.3 53 53 53 47 41 34 28 57 55 4.7 55 55 55 48 42 36 29 51 5.4 51 51 51 44 38 32 25 72 67 4.9 48 42 36 30 24 - - 65 5.4 47 41 35 29 23 - - 2250 67 62 4.8 59 53 47 41 35 30 24 59 5.2 57 51 45 40 34 28 22 62 56 4.7 56 56 56 50 45 39 33 53 5.2 53 53 53 47 41 35 29 57 54 4.7 54 54 54 48 42 36 31 50 5.3 50 50 50 44 39 33 27 2000 72 66 4.9 45 39 34 29 23 - - 64 5.3 44 39 33 28 22 - - 2000 . 67 62 61 55 4.8 4.7 55 55 50 55 44 55 39 50 34 45 28 39 23 34 58 _ 52 5.1 5.1 54 52 48 52 43 52 38 47 32 42 27 36 22 31 57 53 4.6 53 53 53 48 42 37 32 50 5.2 50 50 50 44 39 34 28 72 63 4.8 41 36 31 27 22 - - 61 5.4 40 35 31 26 21 - - 1750 67 58 4.7 51 46 41 36 32 27 22 56 5.1 49 44 39 35 30 25 21 62 53 4.6 53 53 51 47 42 37 32 50 5.2 50 50 48 43 39 34 29 57 51 4.6 51 51 49 44 40 35 30 47 5.2 47 47 46 41 36 32 27 72 60 4.8 37 33 29 25 21 - - 58 5.4 36 32 28 24 20 - - 1500 67 56 4.7 46 42 38 34 30 26 21 53 5.2 44 40 36 32 28 24 20 62 51 4.6 51 51 47 43 39 35 31 47 5.2 47 47 44 40 36 32 27 57 49 4.6 49 49 45 41 37 33 29 45 5.3 45 45 42 38 34 29 25 Air On Evaporator Coil Temperature of Air on Condenser Coil 105°F 115°F Total Powe Input KW Sensible Capacityl, MBH Total Cap.1 MBH Powe Input KW Sensible Capac'ty1, MBH CFM WB F Cap.1 MBH Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68_ 72 61 6.1 48 41 35 29 22 - - 57 6.7 46 39 33 27 20 - - 2500 67 55 5.9 55 52 46 39 33 27 20 50 6.6 50 50 43 37 31 24 18 62 49 5.9 49 49 49 42 36 30 23 44 6.5 44 44 44 38 31 25 19 57 47 5.9 47 47 47 40 34 28 21 42 6.5 42 42 42 36 30 23 17 72 61 6.0 45 39 33 28 22 - - 57 6.6 43 38 32 26 20 - - 2250 67 62 54 48 5.9 5.8 53 48 49 48 44 48 38 42 32 37 26 31 20 25 50 44 6.5 6.4 50 44 47 44 42 44 36 38 30 32 24 26 18 20 57 46 5.8 46 46 46 40 35 29 23 42 6.4 42 42 42 36 31 25 19 72 60 6.0 42 37 32 26 21 - - 57 6.6 41 36 30 25 20 - - 2000 67 54 5.8 52 47 41 36 31 25 20 50 6.5 50 45 40 34 29 24 18 62 48 5.7 48 48 48 43 37 32 27 44 6.4 44 44 44 38 33 28 22 57 46 5.8 46 46 46 41 35 30 25 42 6.3 42 42 42 37 32 26 21 72 57 6.0 38 34 29 24 19 - - 53 6.5 37 32 27 23 18 - - 1750 67 51 5.8 47 42 38 33 28 24 19 46 6.4 45 41 36 31 26 22 17 62 45 5.7 45 45 44 39 34 30 25 41 6.3 41 41 39 35 30 25 21 57 43 5.8 43 43 42 37 32 28 23 39 6.3 39 39 38 33 29 24 19 72 54 6.0 34 30 26 22 18 - - 49 6.5 33 28 24 20 16 - - 1500 67 48 5.8 42 38 34 30 26 22 18 43 6.4 40 36 32 28 24 20 16 62 43 5.7 43 43 39 35 31 27 23 38 6.3 38 38 35 31 27 23 19 57 41 5.8 41 41 38 34 30 26 21 37 6.2 37 37 34 30 26 22 18 1 These capacities are gross ratings. For net capacity, determine the KW of the supply air blower moto from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit 2 These ratings include the compressor and the condenser fan motors but not the supply ar blower motor. The total condenser fan motor power input is 0.36 KW. Refer to the Blower Performance Table for the KW of the supply air blower motor. NOMINAL RATING 6 ALL SENSIBLE CAPACITY Unitary Products Group 530.18 -TG 1 Y COOLING CAPACITIES - 6 TON (DCE / DCG072) Air On Evaporator Coil Temperature of Air on Condenser Coil 85°F 95°F Total Cap.1 MBH Powe Input KW Sensible Capac'ty1, MBH Total Cap.1 MBH Powe Input KW Sensible Capactyt, MBH CFM WB °F Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 68 72 80 5.7 63 55 47 40 32 - - 77 6.3 63 55 47 40 32 - - 2700 67 62 80 70 5.7 5.5 76 70 68 70 60 70 53 62 45 55 37 47 30 39 77 71 6.3 6.3 75 71 68 71 60 71 53 63 45 56 37 48 30 40 25 27 57 68 5.6 68 68 68 60 52 45 37 71 6.3 71 71 71 63 56 48 40 27 72 82 5.7 60 53 46 38 31 - - 76 6.3 60 53 46 39 31 - - 2550 67 62 82 71 5.7 5.5 73 71 65 71 58 70 51 62 43 55 36 48 29 41 76 70 6.3 6.3 73 70 66 70 58 69 51 62 44 55 36 48 29 40 25 29 57 69 5.6 69 69 69 62 55 47 40 70 6.3 70 70 70 62 55 48 40 29 72 83 5.7 58 51 44 37 30 - - 75 6.3 58 51 44 37 30 - - 2400 _ 67. 62 83 73 5.7 5.5 70 73 63 73 56 70 49 63 42 56 35 49 28 42 _75 69 . 6.3 6.3 70 69 64 69 57 68 50 61 43 54 36 47 29 40 25 31 57 71 5.6 71 71 71 64 57 50 43 69 6.3 69 69 68 61 54 47 40 30 72 79 5.7 54 48 41 35 29 - - 73 6.3 53 47 41 35 29 - - 2100 67 79 5.7 65 59 53 47 40 34 28 73 6.3 65 59 52 46 40 34 28 24 62 69 5.5 69 69 66 60 54 47 41 67 6.3 67 66 63 57 51 45 38 29 57 67 5.6 67 67 67 61 54 48 42 67 6.3 67 66 63 57 51 45 39 29 72 74 5.6 50 44 39 34 28 - - 71 6.3 49 43 38 33 27 - - 1800 67 62 74 65 5.6 5.4 60 65 55 65 50 62 44 57 39 51 34 46 28 41 71 65 6.3 6.2 59 65 54 63 48 58 43 53 38 47 32 42 27 37 23 28 57 63 5,5 63 63 63 58 52 47 42 65 6.3 65 63 _ 58 53 47 42 37 Air On Evaporator Coil . Temperature of Air on Condenser Coil 105°F 115°F Total Cap.1 MBH Powe Input KW Sensible Capac ty1, MBH Total Cap.1 MBH Powe Input KW Sensible Capac'ty1, MBH CFM WB °F Entering Dry Bulb, °F Entering Dry Bulb, °F 86 83 80 77 74 71 68 86 83 80 77 74 71 68 72 76 7.1 61 53 45 38 30 - - 75 7.9 59 51 43 36 28 - _ - 2700 67 62 71 64 7.1 7.0 70 64 66 64 58 64 50 56 43 49 35 41 27 34 65 57 7.8 7.8 65 57 64 57 56 57 48 50 41 42 33 34 25 27 57 64 7.0 64 64 64 56 49 41 34 57 7.7 57 57 57 50 42 34 27 72 76 7.1 59 51 44 37 29 - - 76 7.9 57 49 42 35 27 - - 2550 67 62 71 64 7.1 7.0 69 64 64 64 56 64 49 56 42 49 34 42 27 35 66 58 7.9 7.8 66 58 61 58 54 58 47 51 40 43 32 36 25 29 57 64 7.0 64 64 64 56 49 42 34 58 7.7 58 58 58 50 43 36 29 72 75 7.1 56 49 43 36 29 - - 76 8.0 55 48 41 34 27 - - 2400 67 62 70 64 7.1 7.0 68 64 61 64 54 63 48 56 41 49 34 42 27 35 66 59 7.9 7.8 66 59 59 59 52 59 45 52 38 45 32 38 25 31 57 64 7.0 .64 64 63 56 49 42 35 59 7.7 59 59 58 51 44 37 30 72 73 7.1 52 45 39 33 27 - - 73 7.9 50 44 37 31 25 - - 2100 67 68 7.1 63 56 50 44 38 32 26 63 7.8 61 54 48 42 36 30 24 62 61 7.0 61 61 58 52 46 40 34 56 7.7 56 56 54 48 42 35 29 57 61 7.0 61 61 58 52 46 40 34 56 7.7 56 56 53 47 41 35 29 72 70 7.1 47 41 36 31 25 - - 69 7.8 45 40 34 29 23 - - 1800 67 62 65 59 7.0 7.0 57 59 51 58 46 54 41 48 35 43 30 38 25 32 60 53 7.8 7.7 55 53 49 53 44 49 39 44 33 39 28 33 23 28 57 59 6.9 59 58 53 48 43 37 32 53 7.6 53 53 49 44 38 33 27 I These capacities are gross ratings. For net capacity, determine the KW of the supply air dower motor from the Blower Performance Table, multiply this value by 3.415 MBH / KW to determine the motor heat, and deduct this heat from the gross capacity of the unit. 2 These ratings include the compressor and the condenser fan motors but not the supply air dower motor. The total condenser fan motor power input is 0,36 KW Refer to the Blower Performance Tale for the KW of the supply air blower motor. NOMINAL RATING Unitary Products Group ALL SENSIBLE CAPACITY 7 530.18 -TG 1 Y • SUPPLY AIR BLOWER PERFORMANCE - DCG036 & 048 with Belt -Drive DCG036 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS MODEL DCG AIR FLOW CFM Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM Watts , RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 036 1700 835 705 880 745 923 795 969 860 1013 970 - - - - 1600 811 655 854 695 898 740 942 790 986 840 1029 900 - - 1500 782 610 827 650 871 685 917 730 960 775 1003 825 1046 905 1400 - - 798 595 844 640 889 680 932 720 975 765 1018 790 1300 - - - - 816 590 862 635 907 675 951 715 995 750 1200 - - - - - - 834 585 881 630 927 665 970 705 1100 - - - - - - 809 550 855 590 900 625 942 665 1000 - - - - - - 782 510 829 545 872 858 919 625 900 - - - _ - - - - - 797 500 843 540 890 580 MODEL DCG AIR FLOW CFM Available External Static Pressure - IWG* 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 036 1700 - - , - - - - - - -- 1145 - - - - 1600 - - - - - - - - - - - - - - 1500 - - - - - - - - - - - - - - 1400 1055 875 - - - - - - -- 900 - - - - 1300 1036 780 1066 850 - - - - - 820 940 - - - 1200 1011 735 1047 765 1075 800 - - - - - - - - 1100 987 690 1028 720 1060 750 1084 775 - - - - - - 1000 963 655 1005 680 1040 695 1068 715 1089 735 - - - - 900 936 615 980 645 1020 660 1050 670 1053 680 1090 690 - - NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0 95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. DCG048 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS MODEL DCG AIR FLOW CFM Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 048 2000 843 860 880 925 919 1005 956 1065 993 1145 1030 1195 1067 , 1235 1900 817 775 854 850 893 920 930 995 970 1065 1008 1125 1046 1170 1800 790 700 828 760 867 840 906 905 944 980 985 1040 1025 1100 1700 - - 802 670 840 745 881 815 920 900 961 970 1001 1030 1600 - - - - 818 665 858 740 898 820 940 890 980 950 1500 - - - - - - 842 695 882 755 922 835 962 895 1400 - - - - - - 833 650 867 705 904 765 942 820 1300 - - - - - - - - 858 665 893 725 932 785 1200 - - - - - - - - 847 640 880 680 916 730 MODEL DCG AIR FLOW CFM Available External Static Pressure - IWG* 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM Watts RPM Watts RPM Watts RPM Was RPM Watts RPM Watts RPM Watts 048 2000 1103 1270 - - - - - - - - - - - - 1900 1085 1210 - - - - - - - - - - - - 1800 1064 1145 1102 1180 - - - - - - - - - - 1700 1040 1075 1081 1115 1121 1140 - - - - - - - - 1600 1020 1005 1060 1050 1100 1085 - - - - - - - - 1500 1003 945 1044 995 1086 1035 - - - - - - - - 1400 982 880 1024 920 1067 965 1107 1000 - - - - - - 1300 970 835 1010 870 1053 920 1099 960 - - - - - - 1200 953 780 992 815 1034 855 1080 905 - - - - - - NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0 95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. 8 Unitary Products Group 530.18 -TG 1 Y . SUPPLY AIR BLOWER PERFORMANCE - DCG060 & 072 with Belt -Drive DCG060 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS MODEL DCG AIR FLOW CFM Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM , Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 060 2500 1059 1560 1077 1590 1095 1630 1114 _Watts 1650 1134 1660 1158 1685 1181 1720 2400 1032 1405 1054 1470 1074 1525 1094 1560 1116 1595 1140 1620 1167 1640 2300 1005 1260 1024 1275 1049 1370 1069 1440 1090 1475 1116 1505 1142 1535 2200 980 1160 1002 1170 1022 1190 1044 1250 1066 1350 1090 1410 1117 1440 2100 930 1060 957 1070 983 1080 1010 1100 1039 1160 1064 1260 1092 1340 2000 877 950 908 975 941 1000 976 1020 1009 1050 1040 1100 1070 1225 1900 - - - - 894 885 940 940 980 980 1014 1020 1047 1095 1800 - - - - 855 815 903 860 950 905 988 940 1022 970 1700 - - - -- 1103 - 884 815 925 850 964 880 1001 910 1600 - - - - - - 864 770 908 805 948 835 987 870 1500 - - - - _ - - - - 882 _ 740 926 780 _ 965 830 MODEL DCG AIR FLOW CFM Available External Static Pressure - IWG* 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM Watts RPM Watts RPM Waits RPM Watts RPM Watts RPM Watts RPM Watts 060 2500 - - - - - - - _Watts - - - - - - - 2400 1193 1665 - -- 1157 - - - - - - - - - 2300 1170 1580 1202 1620 - - - - - -- 1190 - - - 2200 1148 1480 1180 1530 - - - - - -- 1135 - - - 2100 1121 1385 1155 1425 1190 1475 - - - - - - - - 2000 1100 1285 1133 1340 1169 1385 1205 1445 - - - - - - 1900 1079 1180 1110 1240 1143 1280 1178 1330 1222 1375 - - - - 1800 1058 1060 1090 1135 1122 1190 1158 1240 1196 1295 - - - - 1700 1035 960 1071 1030 1103 1100 1134 1140 1164 1175 1197 1205 - - 1600 1020 900 1056 965 1088 1035 1118 1065 1145 1105 1170 1130 1198 1150 1500 1004 860 1038 880 1070 925 1101 980 1130 1045 1158 1075 1184 1110 NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0 95. *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1' FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS I ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. DCG072 - SIDE DUCT APPLICATIONS (230/460/575 VOLTS MODEL DCG AIR FLOW CFM Available External Static Pressure - IWG* 0.20 0.30 0.40 0.50 0.60 0.70 0.80 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 072 3200 1150 2325 1182 2425 1212 2525 - - - - - - - - 3000 1100 2010 1129 2090 1157 2150 1185 2225 1215 2290 1242 2360 - - 2800 1045 1700 1074 1780 1102 1850 1131 1940 1160 2025 1190 2075 1217 2130 2600 985 1425 1015 1475 1045 1540 1075 1630 1103 1715 1135 1760 1163 1825 2400 930 1240 958 1300 990 1350 1020 1400 1051 1430 1081 1490 1111 1600 2200 - - 905 1070 933 1160 965 1210 997 1250 1028 1285 1060 1325 2000 - - - -- 1109 - 919 1025 950 1100 982 1130 1014 1160 1800 - - - - -- 1060 - - 909 925 939 1005 968 1030 MODEL DCG AIR FLOW CFM Available External Static Pressure - IWG' 0.90 1.00 1.10 1.20 1.30 1.40 1.50 RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts RPM Watts 072 3200 - - - - 3000 - - - - - - - - - - - - - - 2800 1245 2190 - - - - - - - - - - - - 2600 1193 1920 1222 1990 1250 2060 - - - - - - - - 2400 1142 1675 1173 1730 1205 1800 1234 1885 - - - - - - 2200 1090 1380 1124 1450 1155 1550 1186 1640 1217 1710 1249 1775 - - 2000 1045 1175 1077 1200 1109 1275 1140 1360 1170 1460 1205 1545 1235 1600 1800 998 1050 1028 1060 1058 1060 1087 1075 1118 1150 1148 1250 1176 1360 NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0 95. INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1" FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS / ELECTRIC UNITS 1MTH SIDE DUCT AIRFLOWS. Unitary Products Group 9 530.18 -TG 1 Y SUPPLY AIR BLOWER PERFORMANCE - DCG036, 048, 060, 072 with Direct -Drive GAS HEAT 230/460/575 VOLTS - Side Duct Applications MODEL DCG MOTOR SPEED0.20 Available External Static Pressure - IWG* 0.30 0.40 0.50 0.60 0.70 0.80 0.90 1.00 CFM Watts CFM, Watts CFM Watts CFM Watts, CFM Watts CFM Watts CFM Watts, CFM Watts CFM Watts HI - - - - 1699 825 1650 785 1570 755 1430 725 1360 700 1280 680 1180 655 036 MED 1684 800 1631 780 1582 750 1524 720 1410 690 1324 650 1260 630 1185 610 1100 590 LOW 1487 710 1464 690 1421 670 1367 650 1315 620 1246 605 1185 590 1110 570 1020 545 HI 1996 960 1933 936 1868 910 1795 880 1722 845 1635 820 1544 790 1419 765 1300 740 048 MED 1804 838 1765 810 1714 785 1650 765 1589 735 1508 705 1407 675 1306 645 1195 625 LOW 1681 760 1640 738 1604 715 1541 695 1490 670 1416 645 1337 620 1230 595 1120 575 HI 2400 1155 2338 1125 2274 1095 2167 1045 2096 1010 1990 980 1887 945 1771 905 1629 855 060 MED 2290 1105 2214 1065 2145 1030 2071 990 1990 950 1911 920 1828 885 1724 835 1604 798 LOW 2150 1020 2100 990 2029 950 1965 910 1905 880 1816 838 1724 800 1644 770 1531 710 072 HI 2461 1480 2402 1440 2361 1395 2260 1350 2178 1305 2101 1260 2000 1205 1914 1155 1830 1110 *INCLUDES ALLOWANCES FOR A WET EVAPORATOR COIL, 1' FILTERS, AND THE HEAT EXCHANGERS. REFER TO THE STATIC RESISTANCES TABLE FOR RESISTANCE VALUES ON APPLICATIONS OTHER THAN GAS/ ELECTRIC UNITS WITH SIDE DUCT AIRFLOWS. NOTE: FOR 208 VOLTS, MULTIPLY VALUES BY 0.95. FACTORY -INSTALLED OPTIONS ECONOMIZERS: Units equipped with a factory -installed economizer option have dampers that are positioned by a spring return, fully modulating damper actuator and are capable of introducing up to 100% outdoor air. As the outdoor air intake dampers open, the return air dampers close. The changeover from mechanical refrigeration to economizer operation is determined by a single input electronic enthalpy control or by a dual input electronic enthalpy control. Simultaneous scroll compressor and economizer operation is also possible. The single enthalpy system contains a sensor that monitors the outdoor air which automatically operates the damper actuator allowing the dampers to open or close. The dual enthalpy system contains a second sensor that monitors both the temperature and the humidity of the return air in addition to the outdoor air sensor described for a single enthalpy system. The logic module compares the inputs from both sensors and switches to economizer operation whenever the outdoor air is cooler than the return air for maximum efficiency of the economizer system. The economizer is completely wired and installed at the factory. Only the outdoor air hood, including its filters, need be assembled and installed in the field. BELT DRIVE BLOWERS: Adjustable belt -drive blowers providing maximum flexibility to handle many airflow requirements, are available on all models. FIELD -INSTALLED ACCESSORIES SINGLE INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes a slide -in / plug-in damper assembly with fully modulating spring return motor actuator capable of introducing up to 100% outdoor air, one outdoor air electronic enthalpy sensor and a rain hood with filters. The rain hood is painted to match the basic unit and must be field -assembled before installation. Economizer dampers are 2% low leakage type. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER - Includes the same damper system and rain hood with filters as described for a single enthalpy economizer except this accessory contains two enthalpy sensors. It uses a differential enthalpy control that compares the outdoor air versus the return air. The logic module then optimizes the economizer operation for additional savings over the single input economizer. MOTORIZED AIR DAMPER - Includes a slid-in/plug-in damper assembly with a rainhood and filters. The outdoor air dampers open when the indoor fan motor is energized. The damper is capable of providing 0% through 100% of outdoor return air opening. MANUAL OUTDOOR DAMPER - Provides 0% through 35% or 0% through 100% of return air opening (field adjustable). Designed for duct mounted side or bottom supply/return applications. Includes rain hood assembly and filter. ELECTRIC HEATERS - Include nickel chromium elements, a terminal block, fuses (where required by UL), all the necessary connectors and hardware. All heaters utilize single point power supply hookup. Capacities from 5 KW thru 30 KW heating are available. FUSE BLOCK KITS - These kits have a fuse box with a fuse block and fuses. They're available for all 460-3-60 volt heaters and 208/230-3-60 volt heaters 7 KW and smaller. OUTDOOR THERMOSTAT- A 24 -volt thermostat providing two stages of control for units equipped with electric heat accessories. ROOF CURB -This 14" high full perimeter roof curb is shipped knocked down for field assembly and contains duct supports that can easily be shifted for the desired unit duct arrangement. No insulated deck is required because the unit underside is insulated. START ASSIST KIT - Provides increased starting torque for single phase units in areas with low voltage conditions. It contains a 12.5 OHM PTCR temperature resistor with a support clip and hardware for mounting. LOW AMBIENT KIT -A low ambient controller maintains stable system operation by reducing the speed of the condenser fan motor when the outdoor temperature is between 45 and 0°F. ANTI -RECYCLE TIMER- A timer to prevent the units scroll compressor from short cycling. It assures a 5 -minute off -time between compressor cycles. PROPANE CONVERSION KIT - Converts a gas-fired heater from natural gas to propane. It contains main burner orifices, a pilot orifice and a regulator spring. LOW NOx KIT (natural gas furnaces only) - Contains five stainless steel expanded metal sheets for mounting into the heat exchanger tubes to meet the California low nitrous oxide emission requirements. HIGH ALTITUDE CONVERSION (NATURAL AND PROPANE) - Provides orifices for proper furnace operation at altitudes up to 6000 feet. For propane applications, the propane conversion kit will also be required. GAS PIPING - This kit contains 1/2" pipe nipples, fittings and gas cock (including panel access gaskets) required for bottom gas supply connection with external shut-off. OUTDOOR COIL GUARD - Consists of grille -type sections for installation over the outdoor coil to protect it from damage. WALL THERMOSTAT - The units are designed to operate with 24 -volt electronic and electro -mechanical thermostats. All units can operate with single stage heat / single stage cool thermostats - with or without the economizer. 10 Unitary Products Group STATIC RESISTANCES EXTERNAL STATIC PRESSURE DROP 530.18 -TG 1 Y DESCRIPTION RESISTANCE, IWG CFM 1000 1200 _ 1400 1600 1800 2000 2200 2400 2600 2800 3000 Economizer• 3 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 0.30 Electric Heaters 5 - 15 KW 0.04 0.05 0.06 0.07 0.08 0.10 0.12 0.14 0.16 0.19 0.22 20 - 30 KW 0.06 0.07 0.08 0.09 0.11 0.13 0.15 0.17 0.20 0.23 0.26 Bottom Duct Connections 0.06 0.07 0.08 0.09 0.10 0.11 0.12 0.14 0.16 0.19 0.22 Cooling Onlv2 0.08 0.10 0.12 0.14 0.16 _ 0.18 0.20 0.23 _ 0.26 0.29 0.32 'Deduct these resistance values from the available external static pressure shown in the respective Blower Performance Table. 'Add these resistance values to the available static resistance in the respective Blower Performance Table. 'The presvaet or the economizer is greater 6100%outdoor sir than far 100% ream &. lftre resistsnce oftlte return eiduct system® lessthan 025 Pf , the uritwi delver less CFM during tdecawnveroperator. _Ralfi- *Al motors have solid bases and are inherently protected. These motors; can be selected to operate into their service factor because they are located In the moving etr, upstream of any heating device. ELECTRICAL DATA - Basic Units with Direct -Drive MODEL DCE DCG BLOWER MOTOR' ADJUSTABLE MOTOR PULLEY FIXED BLOWER PULLEY BELT MODEL RANGE MAX. HACR BREAKER SIZE, AMPS MIN. MAX. RLA PITCH PITCH 187 PITCH 18.0 105.0 (RPM) HP RPM FRAME SERVICE DIA. BORE DIA. BORE LENGTH DESIG- 1.3 0.8 4.4 2.2 20.0 10.8 30 15 SIZE FACTOR /in) (in.) (in.) (in.) (in.) NATION DCE / DCG 036 790 - 1120 11/2 1725 56 1.15 2.4 - 3.4 7/8 5.7 1 37.3 A36 DCE / DCG 048 790 - 1120 11/2 1725 56 1.15 2.4 - 3.4 7/8 5.7 1 37.3 A36 DCE / DCG 060 850 - 1220 11/2 1725 56 1.15 2.4 - 3.4 7/8 5.2 1 37.3 A36 DCE / DCG 072 900 - 1250 11/2 1725 _ 56 1.15 2.8 - 3.8 7/8 5.2 1 37.3 A36 *Al motors have solid bases and are inherently protected. These motors; can be selected to operate into their service factor because they are located In the moving etr, upstream of any heating device. ELECTRICAL DATA - Basic Units with Direct -Drive MODEL DCE DCG POWER SUPPLY VOLTAGE LIMITATIONS (SEE NOTE 1) SCROLL COMPRESSOR COND. FAN MOTOR FLA, SUPPLY AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE, (SEE NOTE 2) AMPS MAX. HACR BREAKER SIZE, AMPS MIN. MAX. RLA LRA 208/230-1-60 187 253 18.0 105.0 1.3 4.4 28.2 45 45 036 208/230-3-60 460-3-60 187 414 253 504 11.4 6.2 90.0 45.0 1.3 0.8 4.4 2.2 20.0 10.8 30 15 30 15 575-3-60 518 630 5.0 36.0 0.8 2.2 9.3 15 - 208/230-1-60 187 253 24.4 140.0 1.3 5.0 36.8 60 60 048 208/230-3-60 460-3-60 187 414 253 504 14.1 7.1 105.0 55.0 1.3 0.8 5.0 2.2 23.9 11.9 35 15 35 15 575-3-60 518 630 5.6 44.0 0.8 2.2 10.1 15 - 208/230-1-60 187 253 28.9 165.0 1.3 6.6 44.0 70 70 060 208/230-3-60 460-3-60 187 414 253 504 16.0 8.0 125.0 67.0 1.3 0.8 6.6 3.3 27.9 14.1 40 20 40 20 575-3-60 518 630 6.4 50.0 0.8 3.3 12.1 15 - 208/230-3-60 187 253 20.3 146.0 1.3 6.8 33.5 50 50 072 460-3-60 414 504 10.2 73.0 0.8 3.6 17.2 25 25 575-3-60 518 630 8.2 58.4 0.8 3.6 14.7 _ 20 - NOTES: 1. Utilization Range "A" in accordance with ARI Standard 110. 2. Dual element, time delay type. ELECTRICAL DATA - Basic Units with Belt -Drive MODEL DCE DCG POWER SUPPLY VOLTAGE LIMITATIONS (SEE NOTE 1) SCROLL COMPRESSOR COND. FAN MOTOR FLA, SUPPLY AIR BLOWER MOTOR, FLA MINIMUM CIRCUIT AMPACITY MAX. FUSE SIZE, (SEE NOTE 2) AMPS MAX. HACR BREAKER SIZE, AMPS MIN. MAX. RLA LRA 208/230-1-60 187 253 18.0 105.0 1.3 5.3 , 29.1 45 45 036 208/230-3-60 460-3-60 187 414 253 504 11.4 6.2 90.0 45.0 1.3 0.8 5.3 3.1 20.9 11.7 30 15 30 15 575-3-60 518 630 5.0 36.0 0.8 3.1 10.2 15 - 208/230-1-60 187 253 24.4 140.0 1.3 8.6 40.4 60 60 048 208/230-3-60 460-3-60 187 414 253 504 14.1 7.1 105.0 55.0 1.3 0.8 5.2 2.6 24.1 12.3 35 15 35 15 575-3-60 518 630 5.6 44.0 0.8 2.0 9.9 15 - 208/230-1-60 187 253 28.9 165.0 1.3 8.6 46.0 70 70 060 208/230-3-60 460-3-60 187 414 253 504 16.0 8.0 125.0 67.0 1.3 0.8 6.0 3.0 27.3 13.8 40 20 40 20 575-3-60 518 630 6.4 50.0 0.8 2.4 11.2 15 - 208/230-3-60 187 253 20.3 146.0 1.3 7.3 34.0 50 50 072 460-3-60 414 504 10.2 73.0 0.8 3.7 17.3 25 25 575-3-60 518 630 8.2 58.4 0.8 2.8 13.9 20 - NOTES: 1. Rated in accordance with ARI Standard 110, utilization range "A'. 2. Dual element, time delay type. Unitary Products Group 11 530.18-TG'I Y ELECTRICAL DATA - Cooling / Electric Heating (DCE036 & 048) with Direct -Drive MODEL DCE POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA ELECTRIC HEATERS MINIMUM CIRCUIT AM PACITY MAX FUS SIZE AMPS MAX. SIZE HACK 2 BREAKER AMPS KW STAGES TOTAL AMPS 2CE04500506 4.0 1 19.1 29.4 45 45 2CE04500706 5.6 1 27.1 39.4 45 45 208-1-60 2CE04501006 4.4 8.0 1 38.3 53.3 60 60 2CE04501506 11.9 2 57.4 77.3 80 80 2CE04502006 15.9 2 76.6 101.2 110 110 2CE04500506 5.3 1 22.1 33.1 45 45 2CE04500706 7.5 1 31.3 44.6 45 45 230-1-60 2CE04501006 4.4 10.6 1 44.2 60.7 70 70 2CE04501506 15.9 2 66.3 88.3 90 90 2CE04502006 21.2 2 88.3 115.9 125 125 2CE04500525* 4.0 1 11.0 20.0 30 --I CT W WW 0CA CT 00 2CE04500725* 5.6 1 15.6 25.0 30 036 208-3-60 2CE04501025 2CE04501525 4.4 8.0 11.9 1 2 22.1 33.1 33.1 46.9 35 50 2CE04502025 15.9 2 44.2 60.7 70 2CE04500525* 5.3 1 12.7 21.4 30 30 2CE04500725* 7.5 1 18.0 28.1 30 30 230-3-60 2CE04501025 4.4 10.6 1 25.5 37.4 40 40 2CE04501525 15.9 2 38.2 53.3 60 60 2CE04502025 21.2 2 51.0 69.2 70 70 2CE04500746* 6.8 1 8.2 13.0 15 15 2CE04501046* 10.1 1 12.1 17.9 20 20 460-3-602CE04501546* 2'2 13.6 1 16.4 23.2 25 25 2CE04502046* 19.5 2 23.5 32.1 35 35 2CE04501058 10.6 1 10.2 15.5 20 - 575-3-60 2CE04501558 2.2 15.9 1 15.3 21.9 25 - 2CE04502058 21.2 2 20.4 28.2 30 - 2CE04500506 4.0 1 19.1 36.8 60 60 2CE04500706 5.6 1 27.1 40.1 60 60 208-1-60 2CE04501006 5.0 8.0 1 38.3 54.1 60 60 2CE04501506 11.9 2 57.4 78.0 80 80 2CE04502006 15.9 2 76.6 101.9 110 110 2CE04500506 5.3 1 22.1 36.8 60 60 2CE04500706 7.5 1 31.3 45.3 60 60 230-1-60 2CE04501006 5.0 10.6 1 44.2 61.5 70 70 2CE04501506 15.9 2 66.3 89.1 90 90 2CE04502006 21.2 2 88.3 116.7 125 125 2CE04500525* 4.0 1 11.0 23.9 35 35 2CE04500725* 5.6 1 15.6 25.8 35 35 048 208-3-60 2CE04501025 2CE04501525 5.0 8.0 11.9 1 2 22.1 33.1 33.9 47.7 35 50 35 50 2CE04502025 15.9 2 44.2 61.5 70 70 2CE04500525* 5.3 1 12.7 23.9 35 35 2CE04500725* 7.5 1 18.0 28.8 35 35 230-3-60 2CE04501025 5.0 10.6 1 25.5 38.1 40 40 2CE04501525 15.9 2 38.2 54.1 60 60 2CE04502025 21.2 2 51.0 70.0 70 70 2CE04500746* 6.8 1 8.2 13.0 15 15 460-3-602.2 2CE04501046* 2C 2'2 10.1 13.6 1 1 12.1 16.4 17.9 23.2 20 25 20 25 2CE04502046* 19.5 2 23.5 32.1 35 35 2CE04501058 10.6 1 10.2 15.5 20 - 575-3-60 2CE04501558 2.2 15.9 1 15.3 21.9 25 - 2CE04502058 21.2 2 20.4 28.2 30 - Dual element, lime delay type Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. • These electric heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field installation. 12 Electric Heat Correction Factors Nominal Voltage Voltage KW Cap Multipier 1.00 0.92 0.92 0.92 208 208 240 230 480 460 600 575 Fuse Block 2FB04700425 208/240 Volts 460 Volts 2FB04700546 Unitary Products Group 530.18 -TG 1 Y ELECTRICAL DATA - Cooling / Electric Heating (DCE060 & 072) with Direct -Drive MODEL DCE POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA ELECTRIC HEATERS MINIMUM CIRCUIT AMPACITY FUAX. SIZE AMPS MAX. SIZE HACR BREAKER AMPS KW STAGES TOTAL AMPS 2CE04500506 4.0 1 19.1 44.0 70 70 2CE04500706 5.6 1 27.1 44.0 70 70 208-1-60 2CE04501006 2CE04501506 6 6 8.0 11.9 1 2 38.3 57.4 56.1 80.0 70 90 70 90 2CE04502006 15.9 2 76.6 103.9 110 110 2CE04503006 22.2 2 106.9 141.9 150 150 2CE04500506 5.3 1 22.1 44.0 70 70 2CE04500706 7.5 1 31.3 47.3 70 70 230-1-60 2CE04501006 2CE04501506 6 6 10.6 15.9 1 2 44.2 66.3 63.5 91.1 70 100 70 100 2CE04502006 21.2 2 88.3 118.7 125 125 2CE04503006 29.6 2 123.3 162.4 175 175 2CE04500525* 4.0 1 11.0 27.9 40 40 2CE04500725* 5.6 1 15.6 27.9 40 40 208-3-60 2CE04501025 6 6 8.0 1 22.1 35.9 40 40 060 2CE04501525 2CE04502025 11.9 15.9 2 2 33.1 44.2 49.7 63.5 50 70 50 70 2CE04503025 22.2 2 61.7 85.4 90 90 2CE04500525* 5.3 1 12.7 27.9 40 40 2CE04500725* 7.5 1 18.0 30.8 40 40 230-3-60 2CE04501025 2CE04501525 6 6 10.6 15.9 1 2 25.5 38.2 40.1 56.1 45 60 45 60 2CE04502025 21.2 2 51.0 72.0 80 80 2CE04503025 29.6 2 71.2 97.3 100 100 2CE04500746* 6.8 1 8.2 14.3 20 20 2CE04501046* 10.1 1 12.1 19.3 20 20 460-3-60 2CE04501546* 3.3 13.6 1 16.4 24.6 25 25 2CE04502046* 19.5 2 23.5 33.4 35 35 2CE04503046* 28.8 2 34.6 47.4 50 50 2CE04501058 10.6 1 10.2 16.9 20 - 575-3-60 2CE04501558 2CE04502058 3 3 15.9 21.2 1 2 15.3 20.4 23.2 29.6 25 30 - - 2CE04503058 30.4 2 29.3 40.7 45 - 2CE04500525* 4.0 1 11.0 33.5 50 oo0000 (C) U) U) U) N- C) 2CE04500725* 5.6 1 15.6 33.5 50 208-3-60 2CE04501025 2CE04501525 6 8 8.0 11.9 1 2 22.1 33.1 36.1 49.9 50 50 2CE04502025 15.9 2 44.2 63.7 70 2CE04503025 22.2 2 61.7 85.6 90 2CE04500525* 5.3 1 12.7 33.5 50 50 2CE04500725* 7.5 1 18.0 33.5 50 50 230-3-60 2CE04501025 2CE04501525 6 8 10.6 15.9 1 2 25.5 38.2 40.4 56.3 50 60 50 60 072 2CE04502025 21.2 2 51.0 72.2 80 80 2CE04503025 29.6 2 71.2 97.5 100 100 2CE04500746* 6.8 1 8.2 17.2 v) U) U) U) 0 N N N CO U) 25 2CE04501046* 10.1 1 12.1 19.7 25 460-3-60 2CE04501546* 3.6 13.6 1 16.4 24.9 25 2CE04502046* 19.5 2 23.5 33.8 35 2CE04503046* 28.8 2 34.6 47.8 50 2CE04501058 10.6 1 10.2 17.2 20 - 575-3-60 2CE04501558 2CE04502058 3 6 15.9 21.2 1 2 15.3 20.4 23.6 30.0 25 30 - - 2CE04503058 30.4 2 29.3 41.1 45 - Dual element, time delay type Standard arch breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. • These Necbic heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse block accessories are available for field installation. Unitary Products Group Electric Heat Correction Factors Nominal Voltage Voltage KW Cap Multipier 1.00 0.92 0.92 208 208 240 230 480 460 600 575 0.92 Fuse Block 2FB04700425 2FB04700546 208240 Volts 460 Volts 13 530.18 -TG 1 Y tLtC: I KILAL UAIA - Cooling / Electric Heating (DCE036 & 048) with Belt -Drive MODEL DCE POWER SUPPLY HEATER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA ELECTRIC HEATERS MINIMUM CIRCUIT AMPACITY MAX FUS SIZE AMPS MAX. SIZE HACR 2 BREAKER AMPS KW STAGES TOTAL AMPS 2CE04500506 4.0 1 19.1 30.5 45 45 2CE04500706 5.6 1 27.1 40.5 45 45 208-1-60 2CE04501006 5.3 8.0 1 38.3 54.5 60 60 2CE04501506 11.9 2 57.4 78.4 80 80 2CE04502006 15.9 2 76.6 102.3 110 110 2CE04500506 5.3 1 22.1 34.2 45 45 2CE04500706 7.5 1 31.2 45.7 50 50 230-1-60 2CE04501006 5.3 10.6 1 44.2 61.8 70 70 2CE04501506 15.9 2 66.3 89.4 90 90 2CE04502006 21.2 2 88.3 117.0 125 125 2CE04500525* 4.0 1 11.0 20.9 30 30 2CE04500725* 5.6 1 15.6 26.2 30 30 036 208-3-60 2CE04501025 2CE04501525 5.3 8.0 11.9 1 2 22.1 33.1 34.2 48.1 35 50 35 50 2CE04502025 15.9 2 44.2 61.9 70 70 2CE04500525* 5.3 1 12.7 22.6 30 30 2CE04500725* 7.5 1 18.0 29.2 30 30 230-3-60 2CE04501025 5.3 10.6 1 25.5 38.5 40 40 2CE04501525 15.9 2 38.2 54.4 60 60 2CE04502025 21.2 2 51.0 70.4 80 80 2CE04500746* 6.8 1 8.2 14.1 15 15 460-3-60 2CE04501046* 2C E04501546* 3 1 10.1 13.6 1 1 12.1 16.4 19.1 24.3 20 25 20 25 2CE04502046* 19.5 2 23.5 33.2 35 35 2CE04501058 10.6 1 10.2 16.6 20 - 575-3-60 2CE04501558 3.1 15.9 1 15.3 23.0 25 - 2CE04502058 21.2 2 20.4 29.4 30 - 2CE04500506 4.0 1 19.1 40.4 60 60 2CE04500706 5.6 1 27.1 44.6 60 60 208-1-60 2CE04501006 8.6 8.0 1 38.3 58.6 60 60 2CE04501506 11.9 2 57.4 82.5 90 90 2CE04502006 15.9 2 76.6 106.4 110 110 2CE04500506 5.3 1 22.1 40.4 60 60 2CE04500706 7.5 1 31.3 49.8 60 60 230-1-60 2CE04501006 8.6 10.6 1 44.2 66.0 70 70 2CE04501506 15.9 2 66.3 93.6 100 100 2CE04502006 21.2 2 88.3 121.2 125 125 2CE04500525* 4.0 1 11.0 24.1 35 35 2CE04500725* 5.6 1 15.6 26.0 35 35 048 208-3-60 2CE04501025 2CE04501525 5.2 8.0 11.9 1 2 22.1 33.1 34.1 47.9 35 50 35 50 2CE04502025 15.9 2 44.2 61.7 70 70 2CE04500525* 5.3 1 12.7 24.1 OD O) A CO CO OOO U) U) 35 2CE04500725* 7.5 1 18.0 29.1 35 230-3-60 2CE04501025 5.2 10.6 1 25.5 38.4 40 2CE04501525 15.9 2 38.2 54.3 60 2CE04502025 21.2 2 51.0 70.2 80 2CE04500746* 6.8 1 8.2 13.5 15 15 460-3-60 2CE04501046* 2CE04501546* 2 6 10.1 13.6 1 1 12.1 16.4 18.4 23.7 20 25 20 25 2CE04502046* 19.5 2 23.5 32.6 35 35 2CE04501058 10.6 1 10.2 15.2 20 - 575-3-60 2CE04501558 2.0 15.9 1 15.3 21.6 25 - 2CE04502058 21.2 2 20.4 28.0 30 . - Dual element, time delay type Standard circuit breakers may be used in Canada and on applications over 60 amps where the heaters are separately fused. • These electric heaters DO NOT include a fuse box. It a hue boa is required to meet a local code ((eg., Chicago), the following fuse dock accessories are evadable for field installation. 14 Electric Heat Correction Factors Nominal Voltage Voltage KW Cap Multipier 1.00 0.92 0.92 0.92 208 208 240 230 480 460 600 575 Fuse Block 2FB04700425 208/240 Volts 2FB04700546 460 Volts Unitary Products Group 530.18 -TG 1 Y ELECTRICAL DATA - Cooling / Electric Heating (DCE060 & 072) with Belt -Drive MODEL DCE POWER SUPPLY HER ACCESSORY MODEL NUMBER SUPPLY AIR BLOWER MOTOR FLA ELECTRIC HEATERS MINIMUM CIRCUIT AMPACITY MAX.U SIZE AMPS MAX. SIZE HACR BREAKER AMPS KW STAGES TOTAL AMPS 2CE04500506 4.0 1 19.1 46.0 70 70 2CE04500706 5.6 1 27.1 46.0 70 70 208-1-60 2CE04501006 2CE04501506 8 6 8.0 11.9 1 2 38.3 57.4 58.6 82.5 70 90 70 90 2CE04502006 15.9 2 76.6 106.4 110 110 2CE04503006 22.2 2 106.9 144.4 150 150 2CE04500506 5.3 1 22.1 46.0 70 70 2CE04500706 7.5 1 31.3 49.8 70 70 230-1-60 2CE04501006 2CE04501506 8 6 10.6 15.9 1 2 44.2 66.3 66.0 93.6 70 100 70 100 2CE04502006 21.2 2 88.3 121.2 125 125 2CE04503006 29.6 2 123.3 164.9 175 175 2CE04500525* 4.0 1 11.0 27.3 40 40 2CE04500725* 5.6 1 15.6 27.3 40 40 208-3-60 2CE04501025 2CE04501525 6 0 8.0 11.9 1 2 22.1 33.1 35.1 48.9 40 50 40 50 060 2CE04502025 15.9 2 44.2 62.7 70 70 2CE04503025 22.2 2 61.7 84.6 90 90 2CE04500525* 5.3 1 12.7 27.3 40 40 2CE04500725* 7.5 1 18.0 30.1 40 40 230-3-60 2CE04501025 2CE04501525 6 0 10.6 15.9 1 2 25.5 38.2 39.4 55.3 40 60 40 60 2CE04502025 21.2 2 51.0 71.2 80 80 2CE04503025 29.6 2 71.2 96.5 100 100 2CE04500746* 6.8 1 8.2 14.0 20 O O in in 0 N N N M U) 2C E04501046* 10.1 1 12.1 18.9 20 460-3-60 2CE04501546* 3.0 13.6 1 16.4 24.2 25 2CE04502046* 19.5 2 23.5 33.1 35 2CE04503046* 28.8 2 34.6 47.1 50 2CE04501058 10.6 1 10.2 15.7 20 - 575-3-60 2CE04501558 2CE04502058 2 4 15.9 21.2 1 2 15.3 20.4 22.1 28.5 25 30 - - 2CE04503058 30.4 2 29.3 39.6 40 - 2CE04500525* 4.0 1 11.0 34.0 50 50 2CE04500725* 5.6 1 15.6 34.0 50 50 208-3-60 2CE04501025 2CE04501525 7. 3 8.0 11.9 1 2 22.1 33.1 36.7 50.6 50 60 50 60 2CE04502025 15.9 2 44.2 64.4 70 70 2CE04503025 22.2 2 61.7 86.3 90 90 2CE04500525* 5.3 1 12.7 34.0 50 50 2CE04500725* 7.5 1 18.0 34.0 50 50 2CE04501025 10.6 1 25.5 41.0 50 50 230-3-60 2CE04501525 7'3 15.9 2 38.2 56.9 60 60 072 2CE04502025 21.2 2 51.0 72.9 80 80 2CE04503025 29.6 2 71.2 98.1 100 100 2CE04500746* 6.8 1 8.2 17.3 25 25 2CE04501046* 10.1 1 12.1 19.8 25 25 460-3-60 2CE04501546* 3.7 13.6 1 16.4 25.1 30 30 2CE04502046* 19.5 2 23.5 33.9 35 35 2CE04503046* 28.8 2 34.6 47.9 50 50 2CE04501058 10.6 1 10.2 16.2 20 - 575-3-60 2CE04501558 2CE04502058 2 8 15.9 21.2 1 2 15.3 20.4 22.6 29.0 25 30 - - 2CE04503058 30.4 2 29.3 40.1 45 - Dual element, time delay type ' Standard draft breakers may be used in Canada and on applications over 60 apps where the heaters are separately fused. These decbic heaters DO NOT include a fuse box. If a fuse box is required to meet a local code ((eg., Chicago), the following fuse dodo accessories are available for field installation. Unitary Products Group Electric Heat Correction Factors Nominal Voltage Voltage KW Cap Multipier 1.00 0.92 0.92 208 208 240 230 480 460 600 575 0.92 Fuse Block 2FB04700425 2FB04700546 208240 Wits 460 Volts 15 530.18 -TG 1 Y FIELD WIRING CONTACTOR GROUND LUG • L TYPICAL POWER WIRING FIELD -SUPPLIED DISCONNECT r ? SINGLE -r-> PHASE -11- -0-- 0- - > POWER L J SUPPLY REFER TO THE ELECTRICAL DATA TABLES TO SIZE THE DISCONNECT SWITCH, OVERCURRENT PROTEC- TION AND WIRING. T I I I GROUNDL LUG CONTACTOR L • L FIELD -SUPPLIED DISCONNECT r1 1 r. —I -0-Y13--r- L J THREE PHASE POWER SUPPLY TYPICAL CONTROL WIRING COOLING ONLY (24 VOLT THERMOSTAT) COOLING ONLY (24 VOLT THERMOSTAT) THERMOSTAT` UNIT TERMINAL TERMINALS STRIP T01 If•veliT“Valtiirxr =WASP COOLING / HEATING (ELECTRONIC THERMOSTAT) MULTI -STAGE ADO JUMPER ADD JUMPER THERMOSTAT TERMINALS UNIT TERM NAL STRIP TBI 24 VOLT TRANSFORMER NOT USED 4 EJECTROLSC PWOORMMUME THERMOSTAT 2ETSSTOMIN P10.MCES SUBBASE) WEE. STALE COOLING M NOT REQUIRED,. UNITE LESS ECONOMIZER. SECO. STAGE .ATINO 13 ONLY REEPAREC ON UNITS WIN • two STAGE ELECTRIC HEATER TO REMOTE SENSOR 2711040702224 IF USED TOR PS ialn To CLOSE THWm E OUTDOOR eWNONCER°ALPEAi . wIENN E. COOLING / HEATING (24 VOLT THERMOSTAT) ADD JUMPER COOLING/HEATING (24 VOLT THERMOSTAT) THERMOSTAT' TERMINALS UNIT TERMINAL STRIP TBI 24 VOLT TRANSFORMER '24 VOLT THERMOSTAT 2710170102. IF THE UNIT HAS AN ECONOMIZER REMOVE JUMPER J1 FROM TERMINALS B AND ID ON TOE RELAY BOARD TO PREVENT SIMULTANEOUS OPERATION OF TME COMPRESSOR AND TME ECONOMIZER. IF YOU WANT TO CONTROL ]MER ECONOMIZER ON A SECOND STAGE OF COOLING OR NAVE AND ELECTRIC MEAT ACCESSORY WITH TWO STAGES OF MEAT, USE THERMOSTAT 2TI1501024 COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE COOLING / HEATING (ELECTRONIC THERMOSTAT) SINGLE STAGE THERMOSTAT' TERMINALS UNIT TERMINAL STRIP TBI 24 VOLT TRANSFORMER 'ELECTRONIC PROGRAMMABLE THERMOSTAT 2Em]N10240NO.UDESSUBSASEI. IF THIS UNIT CASAND ECOIOM12ER REMOVE MMPER 11 FROM TERMINALS4 AND ON THE RELAY BOARD TO PREVENT SWLTANEOUS OPERATION OF THE COMPRESSOR AND THE ECONOMIZER M YOUWANT TO CONTROL TIE ECONOMIZER ON A SECOND STAGE OF COOLING, USE THERMOSTAT 2E10470022A. 16 Unitary Products Group . UNIT DIMENSIONS (DCE AND DCG - 3, 4, 5 & 6 TON) FIELD-SUPPUED DISCONNECT SWITCH LOCATION (Direct -Drive units) CONTROL BOX ACCESS BLOWER ACCESS DHE Units 485 Ton CONDENSER SCROLL COMPRESSOR ACCESS ELECTRIC HEAT ACCESS 3(4" PVC FEMALE COND. DRAIN (See Detail "A") BOTTOM SUPPLY S RETURN AIR OPENINGS (SEE NOTE) B - POWER WIRING ENTRY A - CONTROL WIRING ENTRY 8-3/8 All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. FIELD -SUPPLIED DISCONNECT SWITCH LOCATION (Direct -Drive units) FILTER ACCESS - CONTROL BOX ACCESS BLOWER ACCESS 2-1/2 UNIT BASE WITH RAIL Shown separately to illustrate bottom duct openings and power connection locations. NOTE: For curb -mounted units, refer to the duct hanger dimensions of the curb for the proper size of the supply and return air duct connections. VENT AIR CUTLET 11000 CONDENSER 530.18 -TG 1 Y FILTER ACCESS BLOWER MOTOR1010 ACCESS DECONNECTED DISCONNECT SNATCLOCATION MOUNTING BRACKET FOR DISCONNECT SWITCH (Shroud eeet", d ru N• Chewerba,com eHelde the blow•, romy.amWI) WIRING ENTRY (Ss.HDetail 1 A11 ACCESS RAND nOTOR ACMFSS PTANFLTF. . r , u" . .. • . .. CONTROL BOX UTILITIES ENTRY DATA HOLE KNOCKOUT SIZE (DIA.) USED FOR A 7/8" , Control Wring (Side or Bottom)** B 2" • Power Wiring (Side or Bottom) C 1-5/8" Gas Piping (Front) D 1-1/2" Gas Piping (Bottom) *Knockouts In the bottom of the unit can be located by the slice In the insulation. **Do s5t remove the 2" knockout ring. CLEARANCES Front DCE Units 24" DCG Units 32" Back 12" (Less Economizer) 36" (With Economizer or Fixed Air/Motorized Damper) Left Side (Filter Access) 24"(Less Economizer) 36" (With Economizer) Right Side (Cond. Coil) 24" Below Unit 0" Above Unitz 72" (For Condenser Air Discharge) SCROLL COMPR. 1 Units may be instated on combustible floors made horn ACCESS wood or doss A, a or C roof covering material. COMBUSTION AIR ' Units must be instated oudoors. Overhanging structures INLET HOOD or shrubs should not obstruct condenser air discharge outlet NOTES: 43/8 f1(:F Modell: Units end ductwork are approved for zero clearance to combustible =tenets when equipped with electric healers. DCG Models: A 1' dearance must be provided between any combusti- ble material and the supply air ductwork br a distance of 3 feet from the unit. The products of combustion must not be allowed to accumulate within a confined space and recirculate. Locate unit so that the vent air outlet hood is at least: • Three (3) feet above any forced air inlet located within 10 horizontal feet (excluding those integral to the unit). • Four (4) feet below, 4 horizontal feet from, or 1 foot above / 2.1/2 any door or gravity air inlet into the building. Jj • Four (4) feet from electric meters, gas meters, regualtors and relief equipment. 32-5/8 DCG UNITS 3-6 TON I GAS HEAT `----T ACCESS GAS SUPPLY ENTRY 82-114 -- (1/2" NPTI AT GAS VALVE) 314° PVC FEMALE COND. DRAIN (See Detail "Al 5-3(8 32-1/4 BOTTOM SUPPLY & RETURN AIR OPENINGS (SEE NOTE) B - POWER WIRING ENTRY 1 D GAS SUPPLY ENTRY (1/2" NPTI AT GAS VALVE) 32-1/4 UNIT BASE WITH RAIL$ Shown separately to Illustrate bottom duct openings, power and gas piping connection locations. NOTE: For curb -mounted units, rater to the duct hanger dimensions of the curb for the proper size of the supply and return air duct connections. A - CONTROL WIRING ENTRY Unitary Products Group 8.3(8 E> RETURN AIR SUPPLY AIR CONDENSER AIR ''. OUTDOOR AIR (Economizer) 17 loo 530.18-TG1Y UNIT DIMENSIONS - CONT'D. (DCE and DCG - 3, 4, 5 & 6 TON) 171/2 111 REAR VIEW 61h 171/2 SIDE SUPPLY AND RETURN AIR DUCT OPENINGS 4% 77/8 DUCT COVERS - Units are shipped with all air duct openings covered. For side duct applications; 1.Remove and discard the supply and return air duct covers. 2.Connect ductwork to duct flanges on the rear of the unit. For bottom duct applications; 1. Remove the side supply air duct cover to gain access to the bottom supply air knockout panel. 2. Remove and discard the bottom knockout panel. 3. Replace the side duct cover. 4. With filter section access panel removed from the unit, remove and discard the bottom return air knockout panel. 5. Replace the filter access panel. 1.4-2i271/22—.1 15/8 r---1-5/8 ool REAR VIEW 27.271/2 o1c 191/2 2 'f` DETAIL "A" UNIT WITH ECONOMIZER RAINHOOD 4 W CONDENSATE DRAIN (must be trapped) 447/8 L.H. END VIEW 1!193/4,--► loo _f REAR VIEW REAR VIEW FIXED OUTDOOR AIR DAMPER 12 MOTORIZED DAMPER 16-1/2 447/6 101/4 B 31/2 \ A� 81/4 43/8 L.H. END VIEW DETAIL "B" UNIT WITH FIXED OUTDOOR AIR/MOTORIZED DAMPER RAINHOOD 3/4' X 1.1/4" WIDE GASKETING FOR CURB FRAME AND ALL DUCT SUPPORT SURFACES UNIT BASE WOOD NAILER— UNIT BASE RAILS 14" 8" MIN. ABOVE FINISHED ROOF — ' COUNTERFLASHING CURB FRAME— CANT STRIP INSULATION AND ROOFING MATERIAL INSULATION UNIT AND CURB APPLICATION 18 ROOF DECK AND SUPPORT STRUCTURE DIMENSION "A" FIXED OUTDOOR 12 AIR DAMPER MOTORIZED DAMPER Unitary Products Group . ROOF CURB DIMENSIONS - (DCE and DCG - 3, 4, 5 & 6 TON) BACK OF UNIT RETURN' AIR DUCT SUPPORT RAILS SUPPLY* AIR 2" TYP.--->, 530.18-TG1Y SCROLL COMPRESSOR AND CONDENSER END OF UNIT 19-1/2" 37-1/4" DUCT SIZES: Supply Air = 19" x 19" Return Air = 19" x 19" FRONT 73" OF UNIT 'Supply and Return Air (including duct support rails) shown are typical for bottom duct applications. For location of horizontal duct applications (on back of unit), refer to Unit Dimension details. COMPONENT WEIGHTS AND CENTER OF GRAVITY BASIC UNIT OPTIONS/ACCESSORIES DCGCORNER SIZE (heat) UNIT WEIGHT" (lbs.) WEIGHTS* (location, lbs.) DCE UNIT WEIGHT' (lbs.) CORNER WEIGHTS' (location, lbs.) DESCRIPTION WEIGHT (lbs.) "A" "B" "C" "D" 036 (40 Mbh) 625 180 172 133 140 036 565 160 157 123 125 ECONIMIZER 50 036 (79 Mbh) 635 180 177 138 140 048 615 173 170 135 137 MOTORIZED OUTDOOR AIR DAMPER 26 048 (60 Mbh) 675 193 185 145 152 060 640 180 177 140 143 048 (99 Mbh) 685 193 190 150 152 072 720 171 196 189 164 ELECTRIC (n0 EAI DCE only 5 7 KW 18 (79 Mbh) 060 700 200 192 150 158 • Might = Unit + Economizer. / CORNER "D" 10-115 23 060 (99 Mbh) 710 200 197 155 158 20KW30 28 072 (79 Mbh) 775 186 209 201 179 ROOF MOUNTING CURB 92 072 (99 Mbh) 785 186 214 206 179 RELIEF/FIXED AIR DAMPER 10 BELT -DRIVE BLOWER 5 CORNER "A" DIM. 3 - 5 TON 6 TON Y 19-3/4" 22" BACK OF UNIT 82t/4 APPROXIMATE X 40-3/4" 44" CENTER OF GRAVITY Unitary Products Group FRONT OF UNIT CORNER"B' Y CORNER "C" CONDENSER COIL END OF UNIT 19 530.18-TGW TYPICAL APPLICATIONS ROOF JACK 7 INSTALLATION 0 ci I I I I IFI 1111111MMMINNINI.INEMSMINS111111 ------ ROOF CURB INSTALLATION SLAB ON GROUND INSTALLATION I) FIELD -SUPPLIED DISCONNECT SWITCH TYPICAL ROOF -TOP INSTALLATION (MODEL DCG SHOWN) J. CONDENSATE TRAP CONTROL WIRING TO TO INDOOR POWER THERMOSTAT SUPPLY OSUPPLY AIR DUCT RETURN AIR DUCT ROOF CURB MANUAL GAS SHUT-OFF VALVE TO GAS SUPPLY LINE 20 Unitary Products Group MECHANICAL SPECIFICATIONS GENERAL DESCRIPTION Units shall be factory -assembled, single packaged, (DCG Electric Cooling/Gas Heat, DCE Electric Cooling/Optional Electric Heat), designed for outdoor mounted installation. Units shall have minimum SEER ratings (036 thru 060) of 10.0 and minimum EER ratings (072) of 9.0. They shall have built in field convertible duct connections for down discharge supply/return or horizontal discharge supply/return, and be available with factory installed options or field installed accessories. The units shall be factory wired, piped, charged with R-22 refrigerant and factory tested prior to shipment. All unit wiring shall be both numbered and color coded. Enclosed in each unit shall be a factory test log sheet consisting of the unit tested pressures, temperatures and amps, as tested prior to shipment. All units shall be manufactured in a facility certified to ISO 9001 standards, and the cooling performance shall be rated in accordance with DOE and ARI test procedures. Units shall be UL listed and classified to ANSIZ21.47 standards and UL 1995/CAN/CSA No. 236-M90 conditions. UNIT CABINET 1. Unit cabinet shall be constructed of G90 galvanized steel, with exterior surfaces coated with a non -chalking, powered paint finish, certified at 750 hours salt spray test per ASTM - B117 standards. 2. Indoor blower section shall be insulated with up to 1" thick insulation, coated on the air side. Aluminum foil faced insulation shall be used in the furnace compartment and be fastened with ridged fasteners to prevent insulation from entering the air stream. 3. Cabinet panels shall be "large" size, easily removable for servicing and maintenance. 4. Full perimeter base rails shall be provided to assure reliable transit of equipment, overhead rigging, fork truck access and proper sealing on roof curb applications. 5. Disposable 1" filters shall be furnished and be accessible through a removable access door, sealed air tight. Units filter track shall be designed to accommodate either 1" or 2" filters. 6. Fan performance measuring ports shall be provided on the outside of the cabinet to allow accurate air measurements of evaporator fan performance without removing panels or creating air by-pass of the coils. 7. Units vertical discharge and return duct configuration shall be designed to fit between standard 24" O.C. beams without modification to building structure, duct work and base unit. 8. Condensate pan shall be internally sloped and conform to ASHARE 62-89 self -draining standards. Condensate con- nection shall be a minimum of 3/4" I.D. female and be a ridged mount connection. INDOOR (EVAPORATOR) FAN ASSEMBLY 1. Fan shall be direct drive, multi -speed, or a factory installed belt drive, adjustable -pitch motor pulley option. Job site selected (B. H. P.) brake horse power shall not exceed the motors name- plate horse power rating, plus the service factor. Units shall be designed not to operate above service factor. 530.18 -TG 1 Y 2. Fan wheel shall be double -inlet type with forward -curved blades, dynamically balanced to operate smoothly through- out the entire range of operation. Airflow design shall be constant air volume. 3. Bearings shall be sealed and permanently lubricated for longer life and no maintenance. OUTDOOR (CONDENSER) FAN ASSEMBLY 1. The outdoor fan shall be of the direct -driven propeller type, discharge air vertically, have aluminum blades riveted to corrosion resistant steel spider bracket and shall be dy- namically balanced for smooth operation. 2. The outdoor fan motor shall be totally enclosed with perma- nently lubricated bearings and internally protected against overload conditions. REFRIGERANT COMPONENTS 1. Compressors: A. Shall be fully hermetic type, advanced scroll design, with patented check valve to eliminate backspin noise at shut- down, internally protected with internal high-pressure re- lief and over temperature protection. The hermetic motor shall be suction gas cooled and have a voltage range of + or - 10% of the unit nameplate voltage. B. Shall have sound muffling to minimize vibration and noise, and be externally isolated on a dedicated, inde- pendent mounting. 2. Coils: A. Evaporator and condenser coils shall have aluminum plate fins mechanically bonded to seamless internally - enhanced copper tubes with all joints brazed. Special Phenolic coating shall be available as a factory option. B. Evaporator and Condenser coils shall be of the direct expansion, draw-thru design. 3. Refrigerant Circuit and Refrigerant Safety Components shall include: A. Independent fixed -orifice expansion devices. B. Filterdrier/strainer to eliminate any moisture orforeign matter. C. Accessible service gage connections on both suction and discharge lines to charge, evacuate, and measure refrigerant pressure during any necessary servicing or troubleshooting, without losing charge. D. The refrigeration system shall provide at least 15° F of liquid sub -cooling at design conditions. 4. Unit Controls: A. Unit shall be complete with self contained low -voltage control circuit protected by a resetable circuit breaker fuse on the 24 volt transformer side. B. Unit shall incorporate a lock -out circuit which provides reset capability at the space thermostat or base unit, should any of the following standard safety devices trip and shut off compressor: (1) - Loss-of-charge/Low-pressure switch. (2) - High-pressure switch. (3)- Freeze -protection thermostat, evaporator coil. If any of the above safety devices trip, an LED (light -emitting diode) indicator shall illuminate. C. Unit shall incorporate "AUTO RESET" compressor over temperature, over current protection. D. Unit shall operate with conventional thermostat designs and have a low voltage terminal strip for easy hook-up. Unitary Products Group 21 530.18 -TG 1 Y GAS HEATING SECTION (DCG Models) 1. Shall be designed with induced draft combustion with post purge logic, energy saving direct spark ignition and redun- dant main gas valve. Ventor wheel shall be constructed of stainless steel for corrosion resistance. 2. The heat exchanger shall be of the tubular type, con- structed of T1-40 aluminized steel for corrosion resistance and allowing minimum mixed air entering temperature of 25° F. 3. Burners shall be of the in -shot type, constructed of alumi- num coated steel and contain air mixture adjustments. 4. All gas piping shall enter the unit cabinet at a single location, through either the side or bottom, without any field modifi- cations. 5. An integrated control board shall provide timed control of evaporator fan functioning and burner ignition. 6. Heating section shall be provided with the following mini- mum protection: A. Primary and auxiliary high-temperature limit switches. B. Induced draft motor speed sensor. C. Flame roll out switch (automatic reset). D. Flame proving controls. ELECTRIC HEATING SECTION (DCE Models) 1 An electric heating section, with nickel chromium elements, shall be provided in a range of 5 thru 30 KW, offering two stages of capacity - 16 KW and above on 208/230 volt heaters and 20 KW and above on 460 and 575 volt heaters. 2. The heating section shall have a primary limit control(s) and automatic reset, to prevent the heating element system from operating at an excessive temperature. 3. The Heating Section assembly shall slide out of the unit for easy maintenance and service. 4. Units with Electric Heating Sections shall be wired for a single point power supply with branch circuit fusing (where required). UNIT OPERATING CHARACTERISTICS 1. Unit shall be capable of starting and running at 125° F outdoor temperature, exceeding maximum load criteria of ARI Standard 210/240. 2. The compressor, with standard controls, shall be capable of operation down to 45° F outdoor temperature. Accessory 1. low ambient kit shall be available for operation to 0° F OPTIONAL OUTDOOR AIR (Shall be made available by either/or): 1. ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER - Outdoor and return air dampers that are interlocked and positioned by a fully -modulating, spring -return damper ac- tuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit -mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in CFM of outdoor air to meet the minimum ventilation requirement of the conditioned space during normal opera- tion. During economizer operation, a mixed -air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from drop- ping below 55°F. Changeover from compressor to econo- mizer operation shall be provided by an integral electronic enthalpy control that feeds input into the basic module. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultaneous economizer/compressor operation is also possible. Dampers shall fully close on power loss. 2. DUAL INPUT DIFFERENTIAL ELECTRONIC ENTHALPY AUTOMATIC ECONOMIZER - Outdoor and return air dampers that are interlocked and positioned by a fully - modulating, spring -return damper actuator. The maximum leakage rate for the outdoor air intake dampers shall not exceed 2% when dampers are fully closed and operating against a pressure differential of 0.5 IWG. A unit mounted potentiometer shall be provided to adjust the outdoor and return air damper assembly to take in the design CFM of outdoor air to meet the minimum ventilation requirement of the conditioned space during normal operation. During economizer operation, a mixed -air temperature control shall modulate the outdoor and return air damper assembly to prevent the supply air temperature from dropping below 55°F. Changeover from compressor to economizer opera- tion shall be provided by two integral electronic enthalpy controls - one that senses outdoor air and one that senses indoor air. Both enthalpy sensors supply input to the logic module which modulates both sets of dampers for maxi- mum economizer savings. The outdoor intake opening shall be covered with a rain hood that matches the exterior of the unit. Water eliminator/filters shall be provided. Simultane- ous economizer/compressor operation is also possible. Dampers shall fully close on power loss. OTHER PRE-ENGINEERED ACCESSORIES AVAILABLE 3. Unit shall be provided with fan time delay to prevent cold air 2. delivery before heat exchanger warms up. (Gas heat only) ELECTRICAL REQUIREMENTS All unit power wiring shall enter unit cabinet at a single factory provided location and be capable of side or bottom entry, to minimize roof penetrations and avoid unit field modifications. Separate side and bottom openings shall be provided for the control wiring. STANDARD LIMITED WARRANTIES Compressor- 5 Years Heat Exchanger- 10 Years Elect. Heat. Elem.- 5 Years Parts - 1 Year 3. ROOF CURB - 14" AND 8" high, full perimeter knockdown curb with hinged design for quick assembly. MANUAL OUTDOOR DAMPER - provides 0% through 35% or 0% through 100% outdoor air capability (field adjustable). Designed for duct mounted side supply/return applications. Includes a hood and a screen assembly. OUTDOOR COIL GUARD - Prevents coil damage. 4. BAROMETRIC RELIEF DAMPER - Contains a rain hood, air inlet screen, exhaust damper and mounting hardware. Used to relieve internal air pressure through the unit during economizer operation. 5. PROPANE CONVERSION KIT- Contains new orifices and gas valve regulator to convert from natural to L.P. gas. 6. LOW NOX - Required to reduce the emission of nitrogen oxides below 40 nano grams per joule. 22 Unitary Products Group • 7. HIGH ALTITUDE - NATURAL GAS - Required for applica- tions between 2000 and 6000 feet altitude. 8. HIGH ALTITUDE - PROPANE GAS - Required for applica- tions between 2000 and 6000 feet altitude. Must be used with propane conversion kit. 9. GAS PIPING - Contains 1/2" pipe nipples, fittings and gas cock (including panel assess gaskets) required for bottom gas supply connection with external shut-off. 10. BURGLAR BARS - Designed to work with above roofcurbs. Fits duct openings of curb supply and return air openings. 11. THERMOSTATS - Multiple models available from A.C.O., M.C.O., Electronic or Electrical Mechanical versions. 530.18 -TG 1 Y 12. ANTI -RECYCLE TIMER - Assures 5 -minute off -time be- tween compressor cycles. 13. LOW AMBIENT KIT - Provides unit cooling operation down to 0°F. 14. ELECTRIC HEAT - Slide -in design, provides single point power and ranges from 5 to 30 KW. OTHER FACTORY INSTALLED OPTIONS 1. HIGH PERFORMANCE BELT DRIVE MOTOR 2. TECHNICOAT PHENOLIC COATED COND. COIL 3. ELECTRONIC ENTHALPY ECONOMIZER 4. DUAL INPUT ELECTRONIC ENTHALPY ECONOMIZER Unitary Products Group 23 • aEFFICIENCY RATING CERTIFIED ama 208230-1.60 VOLT MODELS ONLY 208230, 460 VOLT MODELS ONLY JYORK' LISTED 208!230, 575 VOLT MODELS ONLY Heating and Air Conditioning SHU 10M 898 1.32 Codes: EBY,EGY,RTY Unitary Products Group 5005 Interstate Drive North, Norman, Oklahoma 73069 Subject to change without notice. Printed in U.S.A. Copyright ® by York International Corporation 2000. All Rights Reserved. ISO 9001 CERTIFIED Proud Sparrow of the 2000 U.S. Olympic Teem 530.18-TG1Y(500) Supersedes: 530.18-TG1Y (698) 5/1/2014 City of Tukwila Department of Community Development ABDIRISAK AHMED 14101 TUKWILA INTERNATIONAL B TUKWILA, WA 98168 RE: Permit No. M13-0210 ABU-BAKR ISLAMIC CENTER 14101 TUKWILA INTERNATIONAL BL Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 6/14/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-438-9350 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 6/14/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Jenn Per ul\ fer Marshall t Technician File No: M13-0210 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 ¶ERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-0210 DATE: 11-12-13 PROJECT NAME: ABU-BAKR ISLAMIC CENTER SITE ADDRESS: 14101 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building ivision ` , I NelliPreMvention A [4411$ Public Works n Structural Planning Division n ❑ Permit Coordinator V DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 11-14-13 Complete Incomplete Not Applicable CI Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 41 Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: . Approved Notation: DUE DATE: 12-12-13 Approved with Conditions Not Approved (attach comments) n REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 ALL HITECH HEATING & A/C L. Washington State Department of Labor & Industries Page 1 of 2 ALL HITECH HEATING & A/C LLC Owner or tradesperson FAISAL, MUHAMMAD Principals FAISAL, MUHAMMAD WA UBI No. 603 004 182 14724 NE 4TH PL BELLEVUE, WA98007 425-747-0677 KING, County Business type Limited Liability Company License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Electrical Contractor License specialties HVAC/RFRG License no. ALLHIHH873MW Effective — expiration 07/18/2013 — 07/18/2015 Designated administrator FAISAL, MUHAMMAD License type Electrical Administrator Bond American States Insurance Co Bond account no. 32S208107 Received by L&I 07/18/2013 Insurance No insurance accounts during the previous 6 year period. Savings No savings accounts during the previous 6 year period. License Violations No license violations during the previous 6 year period. Active. Meets current requirements. ACTIVE License no. FAISAM*979MW $4,000.00 Effective date 07/12/2013 Workers' comp No active workers' comp accounts during the previous 6 year period. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=603004182&amp;LIC=ALLHIHH873MW&amp;S... 12/16/2013