Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-0222 - SHOWALTER MIDDLE SCHOOL - REPLACE BOILER
SHOWALTER MIDDLE SCHOOL 4628 S 144 ST M13-0222 Parcel No: Address: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 1523049164 Permit Number: 4628 S 144 ST Project Name: SHOWALTER MIDDLE SCHOOL Issue Date: Permit Expires On: M 13-0222 12/12/2013 6/10/2014 Owner: Name: Address: TUKWILA SCHOOL DISTRICT 4640 S 144TH ST , TUKWILA, WA, 98168 Contact Person: Name: JOHN EIMER Address: Contractor: Name: Address: License No: Lender: Name: Address: 18802 80 AVE S , KENT, WA, 98032 SHINN MECHANICAL 18802 80TH AVE SOUTH , KENT, WA, 98032 SHINNMIO60QP Phone: (425) 204-3942 Phone: (425) 203-9800 Expiration Date: 11/4/2015 DESCRIPTION OF WORK: REMOVE AN EXISTING DOMESTIC WATER BOILER AND REPLACE WITH A NEW HIGH EFFICIENCY CONDENSING BOILER. INCLUDES NEW VENTING. Valuation of Work: $12,265.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $97.50 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: 125 Sewer Distric: VALLEY VIEW SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: Permit Center Authorized Signatur : 11 I Date: 2012 2012 2012 izli Z�l 3 I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit d agree to the conditions attached to this permit. Signature: 1 `l Print Na ri e: Jct? Date: 124 Z,z0 13 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 5: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** 10: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 11: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: t27 -()ZZZ (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 152304-9108 Site Address: 4628 South 144th St, Tukwila, WA 98168 Suite Number: N/A Floor: N/A Tenant Name: Tukwila School District New Tenant: D Yes m..No PROPERTY OWNER Name: John Eimer Name: Tukwila School District City: Kent State: WA Zip: 98032 Address: 4640 South 144th Street Email: johnk@shinmech.com City: Tukwila State: WA Zip: 98168 CONTACT PERSON — person receiving all project communication Name: John Eimer Address: 18802 80th Ave. South City: Kent State: WA Zip: 98032 Phone: (425) 204-3942 Fax: (425) 203-9801 Email: johnk@shinmech.com MECHANICAL CONTRACTOR INFORMATION Company Name: Shinn Mechanical, Inc Address: 18802 80th Avenue South City: Kent State: WA Zip: 98032 Phone: (425) 203-9800 Fax: (425) 203-9801 Contr Reg No.: SHINNMI060QP Exp Date: 11/04/2015 Tukwila Business License No.: 0992858 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Remove an existing domestic hot water boiler and replace with a new high efficiency condensing boiler. Includes new venting. 12,265 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Apphcanon Revised 8-9-11.docx Reviscd: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heatlrefrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 1 15-30 hp/I,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 'N OR UTHORIZED AGENT: Signature: ��'''�n—✓ Print Name: John Eimer Mailing Address: 18802 80th Ave. South Kent WA 98032 City State Zip Day Telephone: Date: 1 V2,-777013 (425) 283-2499 H:\Applications\Forms-Applications On Lme\2011 Applications \Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $289.38 M13-0222 Address: 4628 S 144 ST Apn: 1523049164. $97.50 MECHANICAL $97.50 PERMIT FEE R000.322.100.00.00 $65.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PG13-0160 Address: 4628 S 144 ST Apn 1523049164 $191.88 PLUMBING $191.88 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE, R000.322.100.00.00 $121.00 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R217 R000.322.103.00.00 $38.38 $289.38 Date Paid: Wednesday, November 27, 2013 Paid By: SHINN MECHANICAL, INC. Pay Method: CHECK 039262 Printed: Wednesday, November 27, 2013 9:45 AM 1 of 1 CRAWSYSTEMS INSPECTION RECORD - Retain a. copy with permit INSPECTION N0: PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-36 Permit Inspection Request Line (206) 431-2451 Mia-e2aZ Pr ct: Typepoff lnspe -tion: Address: 71, Date C Iled•,� Special Instructions: Date Wanted: ^ '�ml. P.m. Requester: • •: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: t •` Inspect ;! Date: / REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. A.O.Smith Commercial Gas Boilers VF= FILE COPY UP TO 88% EFFICIENT, HOT WATER SUPPLY BOILER WITH MODULATING FIRE 4:1 TURNDOWN The VF" Boiler series delivers an exceptionally high thermal efficiency by combining an advanced modulating venturi-mixing gas/air ratio system with a vertical multi -pass copper heat exchanger for outstanding efficiency of up to 88% and low NOx emissions that meet or exceed the most stringent.standards. The VF" Boiler is capable of firing from 100% to 25% or a4:1 turndown ratio of rated input based on the current system demand. The VF's modulating capability is virtually limitless, and the boiler's output is based strictly on the current system demand and the required BTUs needed to maintain the desired system set point temperature. ADVANCED HIGH -EFFICIENCY, LOW-NOx COMBUSTION TECHNOLOGY • Venturi -mixing gas/air ratio system - Works with variable speed blower to precisely mix gas and air throughout firing range. • 4:1 Turndown - Fully modulating capability prevents energy -stealing short cycling and provides smooth system operation with higher overall system efficiencies • Approved for use in areas with low pressure gas supply services - Provides good operation with 4 inches of water column LOW-NOx OPERATION • Meets or exceeds Texas and California SCAQMD Rule 1146.2 air quality standards EMC -5000 MODULATING CONTROL • Includes remote tank temperature control to adjust tank temperature at the boiler - Modulates the boiler to maintain tank set point temperature within +/- 1 degree • Infinite boiler output control between 25% and 100% fire • LED read out - Provides current boiler status in plain English with help screens to assist should a fault occur • Controls every electrical boiler function with on board diagnostics ALL -BRONZE FACTORY MOUNTED PUMP • Integrally mounted, wired, and controlled by the EMC -5000 boiler control • Factory sized for proper flow between boiler and storage tank • Allows 50 equivalent feet of piping between boiler and tank VW -500 through VW -1000 HIGH EFFICIENCY COPPER FIN TUBE HEAT EXCHANGER • Vertical straight tube 2 pass heat exchanger design encircles the burner with a combustion chamber that is a 360° wall of copper fin tubes • Rust -resistant operation - All internal heat exchanger non -copper surfaces are RECEIVED glass -lined with A. 0. Smith's proprietary porcelain glass coating, which far CITY OF TUKWIL exceeds competitive coatings • Impervious to thermal shock COMPACT, LOW -PROFILE DESIGN • Zero clearance on sides, ideal for multiple boiler installations • Fits through 30- doors and into elevators for difficult retrofit applications NOV 2 l 2013 PERMIT CENT , R STANDARD -VENT OR DIRECT -VENT FLEXIBILITY • Standard -vent configuration, vertical or horizontal sidewall • Two -pipe direct -venting vertical and/or horizontal sidewall, with all combustion makeup air drawn from outside the building April 2007 ASME A.O.Smith Page 1 014 ACGSS02307 Commercial Gas Boilers Y O3 LII NOTE: Head loss shown is through boiler only and allows For no additional piping C3i C�U.Bt�i . �a 3O14A1-19Moz ECO, 'P0 r 3.:1e 30.0 yy t:6; Sit!l�+q:�t 1t^1 4I Pi"ielVi VW MODELS - 1WOW,.HEAD LOSS AND TEMPERATURE RISE Model 20F° (11°C) AT 30F° (17°C) AT 40F° (22°C) AT Maximum Flow Rate Minimum Flow Rate GPM LPHAP 36 , PM GPM LPH AP Fr A PM GPM LPH AP Fr i PM GPM LPH APAP Ff A PM L T°F A Pm GPM LPH Fr A PM A T°F A Pm VW -500 42 159 1.8 0.5 28 106 1.3 0.4 21 79 1 0.3 100 379 3.8 1.2 8 4 21 79 1 0.3 40 22 GVW -750 63 238 2.9 0.9 42 159 2.1 0.6 32 121 1.8 0.5 110 416 4.3 1.3 12 7 32 121 1.8 0.5 40 22 VW -1000 85 322 3.9 1.2 56 212 2.8 0.9 42 159 2.3 0.7 120 454 4.9 1.5 14 8 42 159 2.3 0.4 40 22 NOTE: Head loss shown is through boiler only and allows For no additional piping C3i C�U.Bt�i . �a 3O14A1-19Moz ECO, 'P0 r 3.:1e 30.0 yy t:6; Sit!l�+q:�t 1t^1 4I Pi"ielVi Dimensions and Shipping Weights t,� iEr t,t ti la A B C D Approx. Shipping Weight (Lbs.) VW -500 Dimensions and Shipping Weights Model # A B C D Approx. Shipping Weight (Lbs.) VW -500 56 22 36 45 450 -.,"› VW -750 62 28 42 51 575 VW -1000 71 34 48 59 750 (4'DIA.I IAIR MARE FLOW SWITCH RELIEF VALVE WATER OUTLET (2'NPT) Please note this product specification sheet is intended to assist with product selection. For the most current product installation and design instructions, please see the latest edition of the Instruction Manual available at www.hotwater.com or call your local A. 0. Smith Sales Representative for assistance. Page 3 or 4 ACGSS02307 1 LEONARD 0%0 WATER TEMPERATURE CONTROLS LV SERIES THERMOSTATIC WATER MIXING VALVES LEONARD LV SERIES THERMOSTATIC WATER MIXING VALVES control water temperature for domestic hot water systems, multiple showers and other commercial, institutional and industrial applications Copper encapsulated thermostatic control ASSE Standard 1017 Listed Mixed water capacities up to 216 GPM (818 I/min) Bronze, brass, and stainless steel construction Integral combination checkstops on inlets Locking temperature regulator Integral wall support Factory preassembled and tested CASPAK® Sizing Program Toll-free technical support • 1-r- /' r Selection/Specification Guide LV SERIES — (MODEL#) — (FINISH#) — (OPTION#) Model LV -981 ' LV -982 3/4" inlets/outlet 2.5 — 44 GPM (9 — 157 1/min) 1" inlets, 1-1/4" outlet 3.0 — 66 GPM (11 — 250 1/min) LV -983 1-1/4" inlets/outlet 5.0 — 126 GPM (19 — 477 l/min) LV -984 1-1/4" inlets, 1-1/2" outlet 6.0 — 148 GPM (22.7 — 560 1/min) LV -985 2" inlets/outlet 10 — 216 GPM (37.9 — 818 1/min) All models are ASSE Standard 1017 listed FINISH RF Rough Bronze CP Chrome Plated OPTION LWS Less Wall Support BDT Ball Valve with Dial Thermometer SAMPLE SPECIFICATION Leonard Model LV- -E- (specify finish) " inlets "outlet GPM minimum flow capacity (see chart, page 5) GPM maximum flow capacity @ PSI system pressure drop LV Series thermostatic water mixing valve, copper encapsulated paraffin -based thermostat, locking temperature regulator handle, integral hot and cold supply checkstops, integral wall support, internal parts of brass, bronze, stainless steel construction. LV Series valve shall be installed and piped according to Leonard's Required Piping Method. LV Series valves are not dependent upon a circulating pump to achieve minimum flow performance. LV -981 LV -982 LV -983 LV -984 LV -985 3 �M20golgt,loam ostat Mater [ M@aizqc@ All LV Series Valves are furnished factory assembled and tested with: Highly responsive copper encapsulated thermostat assembly to control the intake of hot and cold water and regulate mixed water temperature Internal parts of bronze, brass and stainless steel Locked temperature adjustment setting Union angle checkstops (with straine s) for top or bottom supplies Copper encapsulated thermostatic control Integral check valves on hot and cold inlets, wall supports, and locking temperature regulators Temperature Differential: 10°F (6.7°C) between desired mix temperature and hot water supply temperature Maximum hot water supply temperature: 200°F (93°C) Maximum supply pressure: 125 psi hgcjcoda Pip Required Piping Method W HIGH TEMPERATURE FIXTURES FIXTURES SUPPLIED BY TEMPERED WATER BALL VALVE THERMOMETER O 'PS'? HOT WATER SOURCE COLD SUPPLY CHECK VALVE BALANCE VALVE CIRCULATOR CHECK VALVE AQUASTAT BALL VALVE BALL VALVE CHECK VALVE HIGH TEMPERATURE RETURN CIRCULATOR V 4 Flow Capacities 225(852) 210 (795) 195 (738) 180(681) 165)625) 150(568) 135 )511) 120)454) 105(397) 90 )341) 75 )284) 60 (227) 45 (170) 30(114) 15(57) LV -985 5 10 15 20 (0.3) (0.7) (1.0) (1.4) LV -984 LV -983 LV-982�� LV -981 25 30 35 40 45 50 (1.7) (2.1) (2.4) (2.8) (3. ) (3.4) PSI (BAR) Caution: All thermostatic water mixing valves have limitations. They will not provide the desired accuracy outside of their flow capacity range. Consult the above chart and graph and make certain minimum flow is greater than as shown above. MINIMUM SYSTEM PRESSURE DROP (PSIG) FLOW 5 10 15 20 25 30 35 40 45 50 PSI MODEL IN OUT (GPM) .3 .7 .97 1.4 1.7 2.1 2.4 2.8 3.1 3.4 BAR (I/min) 2.5 14 20 24 28 32 35 38 41 43 44 GPM LV -981 3/4" 3/4" 9 53 76 91 106 121 132 144 155 163 167 1/min ALV 982 1„ 1 1/4„ 3.0 11 21 79 31 117 37 170 43 163 48 182 53 201 56 211 60 227 63 238 66 250 GPM 1/min 5.0 39 55 68 79 91 99 109 117 122 126 GPM LV 983 1 1/4" 1 1/4" 19 216 208 257 299 344 375 413 443 462 477 1/min 6.0 50 69 83 97 108 117 126 134 141 148 GPM LV 984 1 1/4" 1 1/2" 22.7 189 261 314 367 409 443 477 507 534 560 1/min LV -985 2" 2" 10 37.9 71 269 99 375 120 454 139 526 154 583 168 636 181 685 193 731 205 776 216 818 GPM 1/min ALL MODELS ARE ASSE STANDARD 1017 LISTED Maximum Flow Capacity 225(852) 210 (795) 195 (738) 180(681) 165)625) 150(568) 135 )511) 120)454) 105(397) 90 )341) 75 )284) 60 (227) 45 (170) 30(114) 15(57) LV -985 5 10 15 20 (0.3) (0.7) (1.0) (1.4) LV -984 LV -983 LV-982�� LV -981 25 30 35 40 45 50 (1.7) (2.1) (2.4) (2.8) (3. ) (3.4) PSI (BAR) Caution: All thermostatic water mixing valves have limitations. They will not provide the desired accuracy outside of their flow capacity range. Consult the above chart and graph and make certain minimum flow is greater than as shown above. COLUMBIA HYDRONICS COMPANY 12828 GATEWAY DR., BLDG #5 • TUKWILA, WA 98168 TELEPHONE 206-241-0500 • FAX 206-241-0520 www.chchydronics.com Letter of Transmittal OR- CCB #199574 To: McKinstry Company Date: 11/22/13 Attention: Zach Simard PO #: Job: Showalter MS Quote #: Location: Tukwila, WA Enclosed please find the following items: X Sets Submittal Data Submittal on CD Sets IOM Manuals IOM on CD Notes: Submittal dimensions are approximate. For fabrication purposes, please request certified prints. We require a copy of the approved submittals for our files. If approved submittals are not returned, all equipment will be ordered as submitted. Remarks: Prepared by: Peter Hague CC: CALIFORNIA HYDRONICS CORPORATION FLOWTHERM SYSTEMS CHC PACIFIC inteIIhotM Commercial Tankless iQ250 Intellihot Commercial Features • Fully condensing, high efficiency • Commercial grade expandable 316L stainless heat exchanger with proven durability • Best 6 Year Commercial HX Warranty • ASME HLW Certified • Continuous hot water - Never run out • Always at set point - Never drop in temperature • 'No'24/7 energy waste with tank standby losses • Best ROI — lower capital costs combined with lower operating costs Operates on very low gas pressure down to 2.5" Takes up 90% less space than a typical tank inteIIhot -;) r (.. �.I What do you need for your business? Dependability, reliability and great performance at a competitive price? A tight space and need to reduce operating costs but can never risk being out of hot water? Intellihot delivers all in an efficient and compact but powerful engine and backs it up with the best commercial warranty in the business. Stainless 316L Construction The internal lines of iQ250 are onstructed out of corrugated stainless steel making this unit robust for long trouble free operation while offering low pressure drop Cycle Proof Heat Exchanger Constructed out of commercial grade 316L stainless steel, Intellihot uses a unique helical and fully expandable heat exchanger (HX), designed to accommodate the quick temperature changes and continual on/off cycles typical of commercial applications. This evolutionary design minimizes the HX stress, guaranteeing longer heater life. The single coil eliminates the need for a primary -to - secondary HX connection, thus eliminates 6 potential leak paths for improved reliability. This HX has superior corrosion and erosion resistance properties and its 3/4" ID offers the lowest pressure drop of any when compared with other primary/secondary heat exchanger tankless designs. Applications The iQ250 rugged tankless can be applied in a variety of mission critical applications that require unlimited hot water. These include restaurants, schools, hospitals, car washes, Laundromats, multifamily housing, etc. Masterless Cascading The iQ250 units can be cascaded upto 10 units for a combined capacity of 2,500,000 BTU/h. Intellihot has no 'system controller PCB' or 'master' configuration that risks a single point system failure. With Intellihot's patented design, each unit has enough intelligence to allow for full lead/lag rotation and for units to be added or removed automatically (if error or for servicing). Intellihot eliminates the risk so your facility will never be out of hot water again! 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 I f I I 1 1 1 1 1 1 30 40 50 60 70 80 90 100 110 120 130 140 inteNhot IQ250 Type Indoor, Wall hung, Fully Condensing Fuel Preset for NG / LP convertible Minimum / Maximum Input (Btu/h) 30,000 / 250,000 Thermal Efficiency 92% Dimensions H X W X D (inches) 25.9 X 17.5 X 14.2 (3.7 cu. ft) Weight (lbs) 90 Water Inlet / Outlet Connection 3/4" NPT Gas Inlet Connection 3/4" NPT Minmum Flow Rate for activation 0.6 GPM Ignition Electronic Spark Ignition Venting Type Direct Vent (2 pipe - intake & exhaust), Power vent (1 pipe - exhaust only) Venting Materials Sch. 40 PVC, Sch. 40 CPVC, Polypropylene, Stainless Steel Max 3' Vent Length - Single Pipe / Power Vent 130 ft, deduct 5 ft per 90• elbow Max 3' Vent Length - Two pipe / Direct Vent 65 ft, deduct 5 ft per 90° elbow Max 2" Vent Length - Single Pipe / Power Vent (2' not allowed at elevations above 4,000 ft) N/A Max 2° Vent Length - Two Pipe / Direct Vent (2' not allowed at elevations above 4,000 ft) Common Venting Yes Safety Flame Rod, Thermal Fuse, Overheat Prevention Device, Fan SpeedMonitor, Flue Temperature Monitor, Blocked Vent Detector, Water Leak Detector, Water Shut Off Valve, 2X10A Fuse, Dual Flame Sensing, Flue Damper Water Pressure Min / Max (PSI) 30 / 160 NG/LP- Minimum Static Gas Pressure 1/2" 6" (non -corrugated, black iron) NG/LP- Minimum Static Gas Pressure 3/4" 2.5" (non -corrugated, black iron) NG/LP - Maximum Static Gas Pressure 14' Gas Pressure for Adjustments 8" for NG, 11" for LP Electrical 120V AC, 60 Hz Power Consum.tion Features Listing 500W Max 4.2 Am.s , 8W Stand. 10250 ETL (Z21.10.3 / CSA 4.3), ASME HLW Cascading Masterless, 10 units Heat exchan.er Performance Ex. •ndable, Stainless 316L 1Q250 Hot Water Capacity (35F Rise) 13.2 Hot Water Capacity (45F Rise) 10.3 Hot Water Capacity (77F Rise) 6.0 Domestic Mode Temp. Settings 100 — 140°F Commercial Mode Tem.. Settin.s Warranty Note: Due to Intel iihors Policy of continuous product improvements, 100 — 190°F Heat Exchanger coil - 6 years Parts — lyear design and technical specifications are subject to change without notice Flow Rates at Various Temperature Rises Y\� — -!- 1250 Temperature Rise - t (°F) i)us Intertek inteIIhot Intellihot Green Technologies Inc. 2900 W. Main Street, Galesburg, IL 61401 phone: 1-877-835-1705 email: sales@intellihot.com www.intellihot.com min oold;itar and ca 2. roarcankm UM lava off 44 44 44 44 4.4 -111 --.15 Alf 'if -If -11f ••••:: •••;;;• •••;•;.... • . . •: •.• •. •. atactong lot Ithantation papa** atch, 4 :141. :4:it :4A :4*.iit 1 1 1 1 1 1 1 1 1 1 11 1 1 bonding taheulagon amp a isolation rano std dad; who* • • 1 1 1 1 1 1 1 1 1 1 1 1 1 .A11 4f Of .Af Of Of 01 Of OW *Of -::":11 ••••:, NJO-Cr anWata lone cad au iv to anallnot mart gas shut oft 1- 1. r hot sum* 1-1 r X1 hot outat atut oft intelOot 4 x 10 units - single temperature no storage - with mixing valve Etrzelasthanlos thmanciatina Lowtot polyptopitono vatting I1.114' loon hong* 2" Mona Ilan. plasma grant rah.. Wf0 SOON. axing loadvd dna valve tactical mount) F4. thalcontal tato* gc roams, Intl pon bat valve * union _a tank squat& (hold *opals* OC1 citcsalatkm pomp 0' pig* diaactotav tl out 1.111C Moves had 410 Normal!, °Wan grata WC Normal), chased alvo • HERMIT COORD COPY M PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-0222 DATE: 11/27/13 PROJECT NAME: SHOWALTER MIDDLE SCHOOL SITE ADDRESS: 4628 .S 144 ST X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: )C 1)=(0-1. AV— g 'Mindin Division sion Fire Prevention Public Works n Structural Planning Division nPermit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12/03/13 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: ilfsi Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DUE DATE: 12/26/13 DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 • Fire 0 Ping 0 PW 0 Staff Initials: SHINN MECHANICAL INC • Washington State Department of Labor & Industries Page 1 of 3 SHINN MECHANICAL INC Owner or tradesperson SHINN, MICHAEL D Principals SHINN, MICHAEL D Doing business as SHINN MECHANICAL INC WA UBI No. 601 585 839 18802 80 TH AVE SOUTH KENT, WA98032 425-203-9800 KING, County Business type Corporation Governing persons DONALDJGILMORE License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties GENERAL License no. SHINNMI060QP Effective — expiration 11/17/1994 —11 /04/2015 Bond HARTFORD CAS INS CO Bond account no. 52BSBDN1736 Received by L&I 11/03/2005 Insurance Continental Western Ins Co Policy no. CWP291378524 Received by L&I 11/19/2013 Savings No savings accounts during the previous 6 year period. Active. Meets current requirements. $12,000.00 Effective date 11/17/2005 $1,000,000.00 Effective date 11/21/2013 Expiration date 11/21/2014 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=601585839&LIC=SHINNMI060QP&SA... 12/12/2013 ABBREVIATIONS GENERAL AD ACT ADJ AFF AEG AMP ARCH AUTO AUX BHP BLDG BOP BOT BTU BTUH CiL CC CLG CFM CO CO2 COL CONN DIA DIM DISCI1 DN DWG EC ELEC ELEV EPO EQUIP ESP (F) FA FON FLEX FLR FP FPM FT FTG GA GALV GC GPM GWB HC HP HT/3 HTR ACCESS DOOR ACOUSTICAL CEILING TILE ADJUSTABLE ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AMPERE ARCHITECT; ARCHITECTURAL AUTOMATIC AUXILIARY BRAKE HORSEPOWER BUILDING BOTTOM OF PIPE BOTTOM BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CENTER LINE COOLING COIL CEILING CUBIC FEET PER MINUTE CARBON MONOXIDE CARBON DIOXIDE COLUMN CONNECT; CONNECTION DIAMETER DIMENSION DISCHARGE DOWN DRAWING ELECTRICAL CONTACTOR; END CAP ELECTRICAL ELEVATION EMERGENCY POWER OFF EQUIPMENT EXTERNAL STATIC PRESSURE FUTURE FAHRENHEIT FIRE ALARM FOUNDATION FLEXIBLE FLOOR FIRE PROTECTION FEET PER MINUTE FOOT; FEET FOOTING GAGE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GYPSUM WALL BOARD HEATING COIL HORSEPOWER; HIGH PRESSURE HEATING HEATER ID INSIDE DIAMETER/DIMENSION 119 INCH LAB LABORATORY LF LINEAL FOOT MAX MBH MC MECH MFR MH MIN MISC MAXIMUM 1000 BRITISH THERMAL UNITS PER HOUR MECHANICAL CONTRACTOR MECHANICAL MANUFACTURER MANHOLE MINIMUM; MINUTE(S) MISCELLANEOUS N/A NOT APPLICABLE NC NORMALLY CLOSED NIC NOT IN CONTRACT NO NORMALLY OPEN; NUMBER NOM NOMINAL NTS NOT TO SCALE OC ON CENTER OD OUTSIDE DIAMETER PERF PERFORATED POC POINT OF CONNECTION PRELIM PRELIMINARY PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE QTY QUANTITY RCP REQD RPM SCL SECT SF SIM SPEC STD STRUC TBD TI TOC TOS TYP UG UH UN0 VFD VSD Wl. W/0 WC WG, REFLECTED CEILING PLAN REQUIRED REVOLUTIONS PER MINUTE SEATTLE CITY LIGHT SECTION SQUARE FOOT SIMILAR SPECIFICATION STANDARD STRUCTURAL TO BE DETERMINED TENANT IMPROVEMENTS TOP OF CONCRETE TOP OF STEEL TYPICAL UNDERGROUND UNIT HEATER UNLESS NOTED OTHERWISE VARIABLE FREQUENCY DRIVE VARIABLE SPEED DRIVE WITH WITHOUT WATER COLUMN WATER GAUGE HVAC AC AIR CONDITIONING AHU AIR HANDLING UNIT BDD BACKORAFT DAMPER, • BOD BOTTOM OF DUCT • CT COOLING TOWER CV CONSTANT VOLU .".k DB DRY BULB EA EAT EC EF EXH FCU FD FM FP FSD FTU EXHAUST AIR ENTERING AIR TEMPERATURE EGGCRATE GRILLE EXHAUST FAN EXHAUST FAN COIL UNIT FIRE DAMPER FREQUENCY M ODLILATION FIRE PRIME -1101i; FAN POWERED COMBINATIOli FIREiSMOKE DAMPER FAN TERMINAL UNIT GRD GRILLE, REGISTER, DIFFUSER HR HEATING RETURN HVAC HEATING, VENTILATIlON! AND AIR CONDITIONING LAT LO MAU MD MUA LEAVING AIR TEMPERATURE, LATENT LINEAR DIFFUSER MAKE-UP AIR UNIT ' MOTOR OPERATED DAMPER MAKE UP AIR OA OUTSIDE AIR OBD OPPOSED BLADE DAMPER RA RETURN AIR RAT RETURN AIR TEMPERATURE SA SAT SF SL SLSM SM SP SUPPLY AIR SUPPLY AIR TEMPERATURE SUPPLY FAN SOUND LINED SOUND LINED SHEET METAL SHEET METAL STATIC PRESSURE TOD TOP OF DUCT WB VAV VD PLUMBING AD CO DCW DHW DHWR EWC. FCO FO GAW GRW GWW WET BULB VARIABLE AIR VOLUME VOLUME DAMPER AREA DRAIN CLEAN OUT DOMESTIC COLD WATER DOMESTIC HOT WATER DOMESTIC HOT WATER RECIRCULATION ELECTRICAL WATER COOLER FLOOR CLEANOUT FLOOR DRAIN GARAGE WASTE GREASE WASTE GREYWATER WASTE IE INVERT ELEVATION IW INDIRECT WASTE NPCW NON POTABLE COLD WATER ORL OVERFLOW RAINWATER LEADER PO PLANTER DRAIN; PRESSURE DROP PLBG PRY RWL RPBP SD SS TRW V VTR W WC WH PLUMBING PRESSURE REDUC:Ir'G VALVE RAINWATER LEAEDER REDUCED PRESSURE BACKFLOW PREVENTER STORM DRAIN SANITARY SEWER TREATED RECLAIMED WATER VENT VENT THROUGH ROOF' WASTE WATER CLOSET WATER HEATER PIPING BP BACKFLOW PREVENTER CD CONDENSATE DRAIN CHBWR CHILLED BEAM WATER RETURN CHBWS CHILLED BEAM WATER SUPPLY CHWR CHILLED WATER CHR CHILLED WATER RETURN CHWS CHILLED WATER SUPPLY COND CONDENSATE CWR CONDENSER WATER RETURN CWS CONDENSER WATER SUPPLY EWT ENTERING WATER TEMPERATURE HR HEATING HOT WATER RETURN HS HEATING HOT WATER SUPPLY LWT LEAVING WATER TEMPERATURE PGWW PUMPED GREYWATER WASTE PS PUMPED STORMWATER PW PUMPED WASTE TDH TOP TSP TOTAL DYNAMIC HEAD TOP OF PIPE TOTAL STATIC PRESSURE. PIPING IDENTIFICATION HVAC - — -- •—CFIVdR— CHW'S COOS — — - —CWR— CW'S — — — HWS PLUMBING G GAW GRW GW V ID IRR NPCW ORL PW -- —PRW— RWL — — RWL -- — SD SS— -- .TRW. UD V- W — — W — — — PIPING FITTINGS 0 3 114'=1 • bt I I J VALVES gal VT CIUVR CHVJS CLADS CWR CWS HWR HWS DCW DEN DUWR G GAVJ GRW GWW ID IRR NPCW ORL PW PRW RWL SD SS TRW 110 V Wt W PIPING ACCESSORIES 4AV 4HAV 4 1�1 RPBP NM Mil CHILLED WATER SUPPLY PIPE CHILLED WATER RETURN P1PU CONDENSATE DRAIN PIPE CONDENSER WATER RETURN PIPE CONDENSER WATER SUPPLY PIPE HEATING' WATER RETURN PIPE HEATING WATER SUPPLY PIPE COLD WATER PIPE (POTABLE) HOT WATER PIPE (POTABLE) HOT WATER CIRCULATING (POTABLE) NATURAL GAS PIPE GARAGE WASTE GREASE WASTE GREYWATER WASTE INDIRECT DRAIN IRRIGATION WATER PIPE NON•POTAB;.E COLD WATER OVERFLOW RAINWATER LEADER PUMPED WASTE PUMPED STORM RAINWATER LEADER BELOW GRADE RAINWATER LEADER STORM DRAM FIFE SANITARY SEWER PIPE (SITE) TREATED RECIAI ME D WATER UNDERDRAIN PIPE VENT PIPE (SANITARY) WASTE PiPE WASTE PIPE BELOW GROUND TEE VW/PIPE LIP TEE DOWN W]ELBO'W TEE UP Wt ELBOW TEE UP TEE DOWN 90' ELBOW UP 90' ELBOW DN CAP UNION FLANGE FLEX HOSE CONNECTION DOUBLE BELLOWS FLEX CONNECTION SINGLE BELLOWS FLEX CONNECTION FLOW ARROW CONCENTRIC REDUCER ECCENTRIC REDUCER SLOPE SYMBOL BREAK OR CONTINUATION SYMBOL DOWN SPOUT NOZZLE CLEANOUT 45` ELBOW 45° ELBOW 93° ELBOW 90° ELBOW CROSS TEE WYE TAP. HOSE CONNECTION MOTORIZED 2•WAY VALVE MOTORIZED 3 -WAY VALVE PRESSURE REDUCING VALVE CONTROL VALVE RELIEF VALVE BALL VALVE 3 -WAY GATE VALVE BUTTERFLY VALVE DIAPHRAGM VALVE CHECK VALVE NEEDLE VALVE GLOBE VALVE GLOBE VALVE ANGLE GLOBE VALVE 3 -WAY GATE VALVE PLUG VALVE BALANCING VALVE HOSE BIBB PUMP MANUAL AIR VENT AUTOMATIC AIR VENT HIGH CAPACITY AIR VENT SHOCK ARRESTOR FLOW SWITCH VACUUM BREAKER PRESSURE GAUGE TEMPERATURE SENSOR TEMPERATURE INDICATOR AUTO FLOW VALVE FLOW METER Y STRAINER Y STRAINER W/ BALL VALVE PIPE SLEEVE STEAM TRAP PETES PLUG SUCTION DIFFUSER W/ STRAINER REDUCED PRESSURE BACKFLOW PREVENTOR FUNNEL DRAIN FLOOR DRAIN ROOF DRAIN ROOF OVERFLOW DRAIN FLOOR SINK DUCTWORK ACCESSORIES 1 flfr •1 7 AD AD 12x12 SL 12x12 2'SL R 1 1 (sD Ov- BIROSCREEN OR SCREENED OPE NINA SUPPLY GRILLE RETURN OR EXHAUST GRILLE VOLUME DAMPER MOTOR OPERATED DAMPER AIRFLOW M10NI1Uit REMOTELY OPERATED VOLUME DAL:', ER (YOUNG REGULATOR OR APPROVED; BACK( DRAFT DAMPER COORDINATE WITit CEILING APPURI LliAdl....::,. FLEX CONNECTION FIRE DAMPER ItIR0UGI1 WALL FIRE DAMPER THROUGH FLOOR FIRE/SMOKE DAMPER THROUGH WALL FIREiSMOKE DAMPER THROUGH FLOOR ACCESS DOORS r ACOUSTICALLY LINED DUCT 2' ACOUSTICALLY LINED DUCT CHANGE OF ELEVATION RISE(R) DRGP(0) TRANSITION TURNING VANES SMOKE DETECTOR RETURN / EXHAUST 1 OUTSIDE AIR SUPPLY / TRANSFER AIR DUCTWORK RECTANGULAR DUCT RECTANGULAR DUCT RECTANGULAR DUCT RECTANGULAR DUCT r X " v (ThD LIED SUPPLY AIR DUCT TURNING UP OR TOWARD SUPPLY AIR DUCT TURNING DOWN OR AWAY EXHAUST OR RETURN AIR DUCT TURNING UP OR TOWARD EXHAUST OR RETURN AIR DUCT TURNING DOWN OR AWAY ROUND DUCT TURNING UP OR TOWARD ROUND DUCT TURNING DOWN OR AWAY OVAL DUCT TURNING UP OR TOWARD OVAL DUCT TURNING DOWN OR AWAY FLEXIBLE DUCT INSTRUMENTATION AND CONTROLS THERMOSTAT SENSOR CARBON MONOXIDE SENSOR CARBON DIOXIDE SENSOR OCCUPANCY SENSOR TEMPERATURE SENSOR GRILLE/REGISTER/DIFFUSER DOABLE LINE V i.LII INS SUPPLY AIR DIFFUSER LER Ilv SUPPLY AIR DIi'FLISER u ,..:1 /ITH TI IRO'.`) ARROWS) CCit 6/0 RETURN, EXHAUST I ii IRAI,,FER AIR GRE LE L I/L tt L) I FUSER 11/ 31 t Illi. ill DIFFUSER (WAL 1) ; ER l.(i:Jti119 (ELEVATION''diEV/) HVAC - ANNOTATION EQUIPMENT / LOUVLR TAG [EF.2 '] 1 1;:. . CU TIVE E019S LOUVER ; t•! (alit OF EQUIP. LeiATICN EUtnPMIENT DESIGNATION GRILLE, REGISTER, OR DIFFUSER TAG TYr LODE 1 HEIGHT WIDTH SVJG•WxH xCFI.t CFM1 GENERAL INFORMATION SYMBOLS POINT OF CONNECTION POINT OF DEMOLITION VICINITY MAP LEGAL DESCRIPTION PARCEL N0: 152304-9108 W 500 FT OF S 629.84 FT OF SE 114 OF SE 114 & S 112 OF SW 1r4 OF SE 1/4 LESS W OF E 565 FT OF S 320 FT LESS CO RDS �rISION so FT changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. DRAWING INDEX SHEET TITLE M0.0 LEGEND, DRAWING INDEX, & VICINITY MAP M0.1 GENERAL NOTES, BASIS OF DESIGNI RESPONSIBILITY MATRIX & SCHEDULES M2.0 DEMOLITION PLAN AND FLOOR PLANS M5.0 DIAGRAMS M6.0 DETAILS Permit 'On review 1kr xroval of tit trio+ajorl of ft appra c REVIEWED FOR CODE COMPLIANCE APPROVED DEC 11 2013 City of Tukwila BUILDING !DIVISION RECEIVED CITY OF TUKWILA NOV 2 7 2013 PEIIIVIIT CENTER instry ife Of Your Building SEATTLE: 5005 3RD AVENUE S PO BOX 24567 SEATTLE, WA 98134 1-800-669-6223 PORTLAND: 16790 NE MASON ST PORTLAND, OR 97230 503-331-0234 www.mckinstry.com SEPARATE PERMIT REQUIRED FOR: CI Mechanical Efglectrical IV tufting Otras Piping City of Tukwila BUILDING DIVISION PROJECT: TUKWILA SD SHOWALTER MS 4628 SOUTH 144TH STREET TUKWILA, WA 98168 REGISTRATION; ISSUES: 11 1 18 1 2013 PERMIT SET N0. DATE DESCRIPTION McKINSTRY DIVISION: ENGINEERING DESIGNED BY: JESSICA SANDERS DRAWN BY: CHRIS RILEY CHECKED BY: KRISTINA SING JOB NUMBER: C10300 DATE: 9/20/2013 SCALE: AS SHOWN SHEET TITLE: LEGEND, DRAWING INDEX, AND VICINITY MAP SHEET NUMBER: 13-0222 M0.0 GENERAL NOTES: 1. THE CONTRACTOR IS RESPONSIBLE TO VISIT THE SITE AND DETERMINETHE EXACT EXTENT OF .. _. J C: WORK, COORDINATION, DEMOLITION, TEMPORARY CONSTRUCTION, TEMPORARY FACILITIES, ES 1= , ET , NECESSARY TO COMPLETE THE PROJECT AS INDICATED IN THE CONTRACT DOCUMENTS,; 2INTERRUPTIONS OF SERVICES (POWER, TER HVAC, ETC.)) AND WORK INOCCUP1E TENANT SPACES MUST E1E SCHEDULED THRU THE BUILDING MANAGER A MINIMUM OF 24 HOURS IN ADVANCE, ANY INTERRUPTIONS OR CONSTRUCTION VVHICH WILL AFFECT NORMAL L PERATION OF THE BUILDING OR TENANTS MUST BE SCHEDULED, WITH THE BUILDING MANAGER'S APPROVAL ON AN AFTER-HOURS BASIS. 3. • FURNISH LABOR,h1AT RIALS EQUIPMENT, APPARATUS AND APPURTENANCES REQUIREDUIRED FOR A COMPLETE WORKING AND COORDINATED SYSTEM. MATERIALS, EQUIPMENT, APPARATUS, AND APPURTENANCES SHALL MATCH EXISTING BUILDING STANDARDS IN QUALITY, TYPE AND FINISH, UNLESS OTHERWISE NOTED, VERIFY PHYSICAL DIMENSIONS OF EQUIPMENT, COOINATE THE EXACT T LOCATIONS OF N V PLUMBING EQUIPMENT WITH THE LOCATIONS OF LIGHTING FIXTURES, PIPING, AND OTHER CONSTRUCTION, TO ALLOW FOR PROPER ACCESS TO SERVICE AND MAINTAIN EQUIPMENT PRIOR TO START OF CONSTRUCTION„ 5. COORDINATE THE LOCATION OF PIPING WITH OTHETRADES. PROVIDE OFFSETS. IN DUCTWORK AND PIPING AS REQUIRED AT NO ADDITIONAL CAST TQ OWNER. S. TRADES TOLEAVE 30” CLEARANCIN FRO NT OF MECHANICAL EQUIPMENT ACCESS SS PANELS FOR SERVICING, 7. INSTALL PIPING TO ALLOW MINIMUM ACCESS OF 6" ABOVE AND TO THE SIDE OFTHE ELECTRICAL CABLE TRAYS. 8: SUPPORT CONDUIT AND PIPING INDEPENDENTLY. SUPPORTS ARE INDEPENDENT OF PARTITION AND .CEILINGaYSTEM SUPPORTS: HETRADES HANG OR SUPPORT E UIPMENT, CEILING WIRES, LIGHT IN NO INSTANCE SHALLOT R 4l G , FIXTURE H.NGERS, EETC. FROMHVA C EQUIPMENT ORPI PING. 10,UTTING, FRAMING, PATCHING, AND PAINTING OF WALL, CEILING, AND FLOOR OPENINGS SHALL BE. C.• BY GENERAL CONTRACTOR. THIS INCLUDES OPENINGS THROUGH AREA SEPARATION WALLS 11, OBTAIN WRITTEN APPROVAL OF STRUCTURAL ENGINEER PRIOR TO INSTALLATION OF PENETRATIONS IF NOT SHOWN ON DRAWINGS. 12, REFER TO STRUCTURAL DETAILS FOR EQUIPMENT SUPPORTS. REFER TO THE SPECIFICATIONS MATRIX FOR ADDITIONAL SEISMIC INFORMATION. r BUILDINGTR. 13, UNIT WEIGHTS LOCATIONS HAVE BEEN COORDINATED TO DETERM NE STRUCTURAL ITI NECESSARY TO RELO GAT UNIT, NOTIFY MCKIN TRY ENGINEERING ADEQUACY, IF S N C .:. O . . E A N Q, S. DEPARTMENT FOR RE•COORDINATION: 14.P ROVIDE SEISMIC RESTRAINTS AND ANCHORAGE PER SMACNA AND THE INTERNATIONAL BUILDING CODE FOR PIPING, AND EQUIPMENT. •15. CONCRETE EQUIPMENT CURBS, FLASHINGS SLEEPERS, CONCRETE STATIONS; EMBED PLATES', PIPING RAT SLABS, SUMP BASINS, AND HOUSEKEEPING PADS ARE SHOWN FOR APPROXIMATE LOCATION ANO SIZE AND WILL BE PROVIDED BY THE GENERAL CONTRACTOR, 16. CUTTING AND PATCHING OF ROOF OPENINGS SHALL BE BY THE GENERAL CONTRACTOR. 17. BEFORE MAKING CONNECTIONS TO THE EQUIPMENT FURNISHED BY THE OWNER OR OTHERS,; VERIFY THAT EXACT INFORMATION IS PROVIDED. 16, PROVIDE ACCESS DOORS IN WALLS AND CEILINGS WHERE ACCESS IS REQUIRED TO CONCEALED MECHANICAL OR PLUMBING EQUIPMENT, VALVES, CONTROLS, ANO OTHER DEVICES, 19, PROVIDE PIPE, EQUIPMENT, AND VALVE LABELING FOR IDENTIFICATION, MATCH OWNERS EXISTING LABELING SCHEME IF APPLICABLE, LIGHT FIXTURE CLEARANCE: COQRDINATELOCATIONS OF MECHANICAL WORKTO PROVIDE CLEARANCES .OVER LIGHTING FIXTURES FOR REMOVAL ANDREBLACEMENT. " ' 21. PROVIDE MODIFICATIONS TO THE EXISTING SPRINKLER SYSTEM FOR ALL, REMODEL AREAS. 22. PROVIDE FIRE SAFE PENETRATIONS OF FIRE RATED CONSTRUCTION, SUBMITTAL NOTES: PROVIDE A PLUMBING EQUIPMENT AND'COMPONENT SUBMITTAL PACKAGE. INCLUDE IN THE PACKAGE SUBMITTALS FOR ITEMS INCLUDED ON THE SCHEDULE ANDIORSPECIFICATION SHEETS. ALSO INCLUDE SUBMITTALS FOR VALVES,, GAUGES, AND INSTRUMENTATION. PIECEMEAL SUBMITTALS ARE NOT ACCEPTABLE: THE PIPING CONTRACTOR SHALL PROVIDE FULL SUBMITTALS OF PIPING AND DEVICES FOR APPROVALPRIOR TO PURCHASE; AND INSTALLATION, DEMOLITION NOTES: 1. DEMOLITION DRAWINGS ARE INCLUDED TO GIVE A COMMON BASIS FOR BIDDING AND MAY NOT SHOW EVERY ITEM TO BE DEMOLISHED. VISIT SITE TO DETERMINE AND COORDINATE THE EXACT EXTENT OF DEMOLITION TO FACEPLATE WORK INDICATED BY THE CONTRACT DOCUMENTS. REWORK K EXISTING TERMINATIONS,CONNECTIONS, ETC., TO ACCEPT NEW WORK. PRIOR TO EI START OF ANY DEMO WORK VERIFY EXISTING CONDITIONS AND NOTIFY ENGINEER OF ANY DISCREPANCIES FOR RESOLUTION. 2. REMOVE EXISTING PLUMBING EQUIPMENT AS INDICATED, INCLUDING ASSOCIATED PIPING, .' CONTROL SYSTEMS, AND APPURTENANCES, REMOVE EXISTING PIPING AS INDICATED, :CAP EXISTING OPENINGS NOT BEING REUSED, REMOVE EXISTING PIPING SERVING ITEMS TO BE REMOVED. CAP OR PLUG BRANCH LINES NOT BEING REUSED: 5,; GIVEOWNER THE OPPORTUNITY TO RETAIN ANY REMOVED ITEMS THAT ARE NOT BEING REUSED. DISPOSE OF OTHER ITEMS LEGALLY. 6. CLEAN AND, REFURBISH ITEMS INDICATED TO BE REMOVED AND REUSED PRIOR TO REUSE. GAS DOMESTIC WATER BOILER SCHEDUL TAG # DWkI Al DWII•D1' D'ud1I.D2 DW •D H 3 • D1MIS D4 MANUFACTURER AO.ShMITH INTELLIHO'T Ih:11;1I,IHOT INTEL, IQ 250 _. _ 1 7 — — INTELU:IHOT I0 250 _ __ _ ._._. �..__.._._._.._. 1 MODEL NUMBER VW -750 ...._._. _.- .... +____ _...__. 1' IQ 260 _._._--.--� _ __ - ._. ___ _ 1 i;;! 250 �_- .--------_.__._. ._ 1 ____—._-___._ _ QUANTITY: SERVICE DOMESTIC HOT WATER BUILDINGS A AND KITCHEN DOMESTIC HOT WATER BUILDINGS D LOCKERS DOMES -1+C HOT WATER BUiLDINi,3 0 LOCKERS DOMESTIC HOT WATER BUILDINGS 0 LOCKERS DOMESTIC IC HOT WATER BUILDINGS 0 LOCKERS WATER VOLUME (GALLONS) FLOW RATE 24 21 GPM N/A 6 WA 6 WA 6 NIA 6 STORAGE TANK (EXISTING)318 GAL NIA (NA I'U A N+ (A ENTERING WATER TEMPERATURE 55`F 55°F 55'F 55'F 55'F LEAVING WATER TEMPERATURE WATER CONNECTION SIZE (NPT) 140°F 2' 140'F 314" 140"F 140'F 314 314' 140`F 314" GALLON PER HOUR S RECOVERY 'i 100 DEGREE TEMPERATURE RISE 161 GSH 390 GI'H u i)PH 36u GPH 250 MBH' 360 GPri NATURAL C A P T SAS M LI 750MBH t1 250 MBH 2 c: U v9 � t 13H 250 MBH 2 30 1 _ MB NATURAL OUTPUT GAS P 8., MBH ` 4MBH 230MBti 230 ,. �,�. 1.161-{ 230. B MINIMUM GAS PRESSURE MAXIMUM GAS PRESSURE 5` W.G. 14' W 0 8" W.G. 14" W G 5...'/.G. 14' W.G. 8" W.G. 8" W.G. i4` W.G. 14' W.G. GAS CONNECTION SIZE (NPT)' 1' 314" 314" 314' 314' 3' CPVC VENT SIZE AND TYPE 6' AL29-4C 3' CPVC 3" CPVC 3' CPVC COMBUSTION AIR INTAKE SIZE AND TYPE ELECTRIC REQUIREMENTS . 4' CPVC 12011160 3' CPVC • 12011!60 3" CPVC 120!1160 3' CPVC 12011160' 3' CPVC 12011160 1 4.2 AMPS QUANTITY OF ELECTRICAL CONNECTIONS 1 1 1 1 4 2 AMPS ELECTRICAL REQUIREMENTS 30 AMPS 4.2 AMPS 4 2 Ali PS STORAGE TANK CIRCULATING PUMP WIDTH x DEPTH x HEIGHT YES 30x37.5162 NIA 17.5x14 2x25.9 WA 17.5. 14 2x25.9 NIA 17.5x14 2125.9 NiA 17 5x 14.2x2.5.9 WEIGHT WITH WATER 600 90 90 90 90 ASME TANK NWA NIA NWA NLA NIA NOTES 1.2, 3, 4.5, 6, 7, 8 1, 2, 3; 4. 5.6 1 2 3, 4, 5, 6 1, 2, 3, 4.5, 6 1, 2.3 4, 5, 6 NOTE: 1. PROVIDE WARRANTY 2. PROVIDE CONDENSATE NEUTRALIZATION KIT BY UNIT MANUFACTURER 3. PROVIDE CONDENSATE DRAIN TO NEAREST FLOOR. DRAIN - SLOPE PIPE 114" PER LF TOWARD DISCHARGE. 4. PROVIDE MOUNTING SKID BY UNIT MANUFACTURER 5. PROVIDE GAS REGULATOR AS SCHEDULED AND ITS VENT 6. EXPANSION TANK TO BE RE -USED. 7, PROVIDE STORAGE TANK CIRCULATING PUMP- BY UNIT MANUFACTURER. 8. PROVIDE S1 ()RAGE TANK TEMPERATURE SENSOR - BY UNIT MANUFACTURER. GAS PRESSURE REDUCING VALVE TAG # SERVING BASIS OF DESIGN , r;... ... . __.____PIPE MAKE I MODEL QTY MAX INDIVIDUAL LOAD (BTUIHR) OPERATING 1EIMIP RANGE ("F) SIZE(NPT).. i. VENT CONNECTION SIZE (NPT) STANDARD SPRING PRV-A1 DWH-A1 !IRON B-42 N ITRON r B-42 R - 1 . 1 - 750,000 250,900 LO -20 HIGH 150 LO -20 HIGH 1:i0 1' 3/4' 1" 1" ... . 1• 8. 14 IN. WC PRV-D1 DWH-D1 8. 14 IN WC PRV-D2 D'WH•02 ITRON B-42 R l6 1 250,000 LO -20I4IGH ,,0 3i4" - • 14 IN. we PRV-D3 I RV D W.- D H D3' fO B-2 IT N 4 R 1 0 250, 00 HIGH 113 LO.201 h,H 0 3/4' 1' 8. 14 IN. WC _1 PRl D4 .:I DWH D4 ITRON B 42 R 1 250,000 • 1:3/4'. 50 •20 HIGH � �0 ; 1 . 8 14 IN WC DHW THERMOSTATIC MIXING VALVE SCHEDULE ITEM # J SYSTEM I CRITERIA CRITERIA SOURCE CODE BASIS FOR PROJECT TAG # BASIS OF DESIGN SERVICE QTY MINIMUM FLOW • (GPMI MAXIMUM FLOW (GPM) ) TEM PERATURE OUT ! F_...___._` { 1 I VALVE SIZE INLET (NPT) OUTLET ' PIPE SIZE (NPT) MAKE MODEL INLET NOTES OUTLET I TMV-D1 LEONARD LV -982 DWH•D9' 1 100 30.0 120 1 1' 1 1/4' 2" 2' 1 WASHINGTON STATE ENERGY CODE NOTES: 1.: PROVIDE SYSTEMS, EQUIPMENT, ANO CONTROLS FUNCTIONAL TESTING IN ACCORDANCE WITH 2012 WASHINGTON STATE ENERGY CODE SECTIONS 405.2,3, 40$ 31 408,4:1,3, 408.5.1, 2 ,• PROVIDE SUPPORTING DOCUMENTATION IN ACCORDANCE WITH 2012 WASHINGTON STATE • ENERGY CODE 408.1.3.2 INCLUDING OPERATION AND MAINTENANCE MANUALS, HVAC CONTROL SYSTEM MAINTENANCE AND CALIBRATION INFORMATION, HVAC CONTROL SEQUENCE OF • OPERATIONS, COMMISSIONING REPORT, AND RECORD DRA•WINGS. PROVIDE OWNER SYSTEMS OPERATION TRAINING IN ACCORDANCE WITH 2012 WASHINGTON STATE ENERGY CODE SECTION 408,1.3,2. 4. SYSTEMS SHALL BE INSULATED AS PRESCRIBED IN SECTIONS 403.2.7, 443.2.8 AND 404.6 OF THE 2012 WASHINGTON STATE ENERGY CODE_ FOR ADDITIONAL DETAILS, SEE DUCTWORK AND PIPING; SPECIFICATION MATRICES CONTAINED WITHIN THIS DRAWING SET, SHOWALTER MS DWH REPLACEMENT - BASIS OF DESIGN ITEM # J SYSTEM I CRITERIA CRITERIA SOURCE CODE BASIS FOR PROJECT 1-i 1-2 CGDE CODE. 2312ERT rIATIQNr,L BUILDING ItN LGO£ 2412... INTERNATIONAL MECHANICAL. CODE CITY OFTUKl51lA CITY OF IUKVWLA' 1-3 .ODE C 2012 INTERNATIONAL FUEL SIS L,k.E CITY QF TUK4,ILA 1-4 CODE 2$I2UNIFOIM PLUMBING CODE CITY OF TtJ$WLA 1-5 CODE 2012,\, SHIN GTON STATE ENERGY CODE STATE OF `IASIiINGTLiJ EhJSTIIIGDC',ESTIC'MATER HEAT IWOSYSTE S 1 2-1 EXIST E 5 INCGGAsSY�TEId zosiliGDOI.SESTICV:ATER60LER 0'',H-A0113750143KI.JFUT,THE EXISTIN0001/5STIC'.' TE BOILERDIMi-D0iIS100 4 < _ ' ;, ` SERVAL _ Merl INPUT. THE NEW EQUIPMENT 441LL MATCH EXISTING GAy CQ'NSUFAPTICNI - THERE 44LLL BE NO CHAN.aE TO GAS :, , 1955 DRAIdNGS • FIELD VERIFIED 2-2 2-4 „ EXISTING DOMESTIC WATER IN ., , licATlhsS1STE1.- DVH -A01 PRO410ES DOMESTIC HOT VeATER TO BUILDING A AND B. UNIT IS AT THE END OF ITS USEFUL UFEAND SHALL EE REPLACED THIS UNIT DELIVERS 140•F OUTER )AtiICH IS STORED IN 316 GAL STORAGE TALK. STCRAGE TANK IS IN GOCC CONDITION AND 1MLL REMAIN 114 SERVICE THE PUMP REC fiCULATINGWATER SETY,EEN STORAGE TANK AND WATER HEA i ER 1'dii5EREPtACEO THE HOT VATERSYSTEMIIASI'AOD$STRISOTiel <'°'1 P BRANCHES 1 0 WATER TEMPERATURE SERVING {JTCHEN AND 120'FWATER TEMPERATURE SERVINGLAVATORIESANDSINKS THE BRANCH SER NN0LAVATORIESAria51`.,45 , - T S ` r I,SkO[iIP�E0IME ISTItrGPsl-LU,STNER105TATI l,1UUHGVRLT.IRIS`fALIEISIhCPFJTA1tCNALGONDITICYVAND111eL t RCI,. J1,11N SERVICE. THE HOI V.4T'eR RETURN CIRCULATING PUMPS FOR 140F A.110 1207 BRANCH AND EXFANSIO`•l Tkt:bi SERVING THIS SYSTEMS ARE IN GOOD CONDITION AND LULL REMAIN IN SERVICC. DVA--,-D0I PROVIDES DOMESTIC HOT'MIER TO GY7.1 LOCKERS. UNIT IS AT THE 50E101 I10 USEFUL LIFE AND SHAWL BE REFS.AGED THE 110T WATER RECIRCULATING POMP AND EXPANSION TANK ARE IN GOOD CO11OIT10N AND VdLL RE014lN 211 SERVICE . 19550RA1dt1fi5 FIELD VERIFIED ` CONTROLS II E DOMESTIC 1t'ATERHEATERS OPERATE BASED ONSCHEDULE PROVIDED 0YBAS FELD.VERIFIEO BASIS FOR P0l. ESTICWATER HEATING 5YSTEl9 L IC GAS SYSTEM GAS USAGE REM+JN&AS IS- GAS METERS TO REMAIN IN SERVICE. PRESSURE REGULATING VALE FCR EACH 4wTER HEATER. SEE SCHEDULE FOR SELECTIC#N. DESIGN APPROACHP(C1i0E 3.2 tiE>11IIG VAT ER SYSTE6# PRO -IDE A 0 SMITH V0750 DOMESTIC WATER BOILER 70 SERVE BUILDING A AND B THIS UNIT IS EQUIPPED VS INTEGRAL CIRCULATING FUMP11-IICH VILL SERVE THE WATER LOOP SE i AEEN 801ER AND EXISTING STORAGE TANK NEW TEMPERATURE SENSOR 4'ALl BE PRO'ODED FOR STORAGE TANK THE 6055(0 0,5511.{PUTE IS 760 MBH GAS EG_ , . $ REGULATOR SHALL BE PROVIDED. PRO'0405 FOUR (41 INTELUHOT INSTANTANEOUS .DOMESTIC WATER HEATERS TO SERVE GYM LOCKERS 114 BUILDING!). THE TOTAL HEATERS GA8 (NPUT IS 1005 MBli GAS REGULATOR FOR EACH UNIT SIiAI L 8E PROVIDED, , DESIGN APPROACH COriTROIS 8 SIS 4-1 EXISTING BAS CO4TROi SYSTEM TO BE RE -CONNECTED TO PRO'ADE EMOEDES.A3LE SIGNAL TO D014061IC HOT WATER 00NTRC(.S BOILERS AND CIRCULATING PUMPS. DEVON APPROACH SHOWALTER MS RESPONSIBILITY MATRIX EQUIPMENT FURNISH ` RECEIVE INSTALL WIRE CONTROLS I START-UP DEMOLITION ws^ , , 0. ONCE T.F7v DOMESTIC WATER BOILERS g1" 1" TO 1.112" k#G £G 4" TO 8' cc HANGERS G FLUES. AIR INT ACES AND APING DEl1 LITIGN C� EX STING _...- ---. �___... DOMESTIC WRTERSCALERS _._.. 'tkt; ._ IBC MCr-EC• 0.5 0 5 __.—.. MC C CC MC D1,HAPPURTENANCES (GAS RECJJLATCR,NEUTRAUZATIONTANK, A0JASTATj 1.101 MC MC MC 1.0 1.0 GAS REGULATOR VENTS L IC lay, CC 1. HOT PIPING LARGER THAN 2', UTILIZE RIGID INSERTS. INSULATION CONTINUOUS THROUGH THE HANGER. SHEETMETAL SHIELD. 2. HOT PIPING 2" AND SMALLER, UTILIZE RIGID INSERTS. INSULATION CONTINUOUS THROUGH THE HANGER. SHEETMETAL SHIELD. i. JAI I! •:. C JAC L ... .- tCt NG: NVI, Kf=1 VW I H P(It�IU kllilU UAL SITTER I E. INSULA i TUN WILL lit U3tU ON ALL. HUh{LUN f AL NININt4 AI LTH ryERk I Hk kLUllK bUHJti.l ! L? i UI kN I ULL 1'U(.k l 1 t,llFh 1G.. k'VG JAGKt I WILL BE UTILIZED ON ALL EXPOSED INSULATION WITHIN 6 FEET OF THE FLOOR ELEVATION (I.E, MECHANICAL ROOMS AND GARAGE HOSE 81B8S). PVC IS RECOMMENDED INSTEAD OF METAL IN EXPOSED CONDENSATE DRAIII4 h#C IBC MC ; THERMOSTATIC VALVE MC I,I0 140 FLUE AND AIR INTAKE M0 M0 " IOC ROOF OPENINGS OC INSULATINGPIPoN0 ANDEGUIPLIEh7 Mu MC - h(G F,FIIIG PLUMBING. ASSOCIATED APPURTENANCES MC LIC MC ^ i _.. , ,. 4C1,.l.,ISSKISINGTESTIN•oG aALANGIN�G _ : .. _...... CCr1E,#IS CJ,71. AGE:T 6IcK-1.1:KINSTRY ESSENTIO:. CA - COMAtiSSIU4ING AGENT MC MECHANICAL CONTRACTOR CC • CCIJTROLSAND LOWSOLTAGE CONTRACTOR GC - GENERAL CONTRACTOR. FA • FIRE ALARM COW RACTCR EC- ELECTRICAL CONTRACTOR PIPE & E * UIPMENT INSULATION SCHEDULE PIPING SYSTEM TEMP RANGE THERMAL COND. MEAN RATING TEMPERATURE INSULATION MATERIAL INSULATION THICKNESS BY PIPE SIZE INSUL. g1" 1" TO 1.112" 1.112" TO 4" 4" TO 8' > 8"- HANGERS DOMESTIC COLD WATER ALL 0.23.0:27 75FIBERGLASS 0.5 0 5 0.5 0.5 0.5 NOTES 1, 2, & 3 DOMESTIC HOT WATER > 105 0.24428 100 FIBERGLASS 1.0 1.0 1,5 1.5 15 NOTES 1, 2, & 3 NOTES: ' 1. HOT PIPING LARGER THAN 2', UTILIZE RIGID INSERTS. INSULATION CONTINUOUS THROUGH THE HANGER. SHEETMETAL SHIELD. 2. HOT PIPING 2" AND SMALLER, UTILIZE RIGID INSERTS. INSULATION CONTINUOUS THROUGH THE HANGER. SHEETMETAL SHIELD. i. JAI I! •:. C JAC L ... .- tCt NG: NVI, Kf=1 VW I H P(It�IU kllilU UAL SITTER I E. INSULA i TUN WILL lit U3tU ON ALL. HUh{LUN f AL NININt4 AI LTH ryERk I Hk kLUllK bUHJti.l ! L? i UI kN I ULL 1'U(.k l 1 t,llFh 1G.. k'VG JAGKt I WILL BE UTILIZED ON ALL EXPOSED INSULATION WITHIN 6 FEET OF THE FLOOR ELEVATION (I.E, MECHANICAL ROOMS AND GARAGE HOSE 81B8S). PVC IS RECOMMENDED INSTEAD OF METAL IN EXPOSED AREAS DUE TO ITS RESILIENCY. PROVIDE STAINLESS STEEL JACKET FOR OUTDOOR SUPPLY/RETURN WATER PIPING. • .., .... ,,,,, . „...a.. '.,.t., REVIEWED FOR CODE COMPLIANCE APPROVED DEC 11 2013 City of Tukwila BUILDING DIVISION PROJECT: For Th instry ieBuilding e •ur SEATTLE: 5005 3RD AVENUE 5 PO BOX 24567 SEATTLE. WA98134 1-800-669-6223 PORTLAND: 16790 NE MASON ST. PORTEAND, OR 97230 503-331-0234 www.mckinstry.com TUKWILA SD SHOWALTER MS 4628 SOUTH 144TH STREET TuoviLA, INA 98168 . 111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111111 REGISTRATION: 11 / 18'/ 2013 PERMIT SET 0. DATE' MCKINSTRY DIVISION; DESIGNED BY: DRAWN BY: GHECI(EO BY KRISTINA SING J►OB, NUMBER: 010300 DES CRIR! ION ENGINEERING. JESSICA SANDERS.> CHRIS RILEY DATE: SCALE . AS SHOWN 9/20/2013 ( deft.- SHEET TITLE: GENERAL NOTES, BASIS OF DESIGN, RESPONSIBILITY MATRIX & SCHEDULES' RECEIVED, • CITY OF TUKWILA NC/2/2013 PERMIT CENTER SHEET NUMBER M0.1 rt r ? 1 iSIATIC 'VALVE ASSEl Bi.4'. r 2 int' 1120' Ft KEY NOTES: • DEMOLISH DOMESTIC WATER HEATER. 0 DEMOLISH SECTIONS OF HOT WATER PIPING AND STORAGE WATER CIRCULATING PUMP. 0 DEMOLISH EXISTING FLUE, ROOF OPENING TO BE RE -USED: 4 DEMOLISH GAS PIPING AND REGULATORS. REGULATOR VENT 1.O BE RE -USED, DEMOLISH SECTION OF PIPE. FOR DIAGRAM SEE 1 IM6.0._. 3'•5 4-pHS'ar< • !FERIA Ct li:.1 EN• BUILDING A BOILER ROOM - DEMOLITION PLAN SCALE:114"=i`°0 8' tilE ,litat;ICAlt &TTis. ABti)VE LOOKERS Cd KEY NOTES: DEMOLISH DOMESTIC WATER HEATER. DEMOLISH COMBUSTION AIR DUCT FROM 12' ABOVE FLOOR TO ROOF. ROOF OPENING TO BE RE -USED • DEMOLISH EXISTING FLUE, ROOF OPENING TO BE RE -USED. • DEMOLISH GAS PIPING AND REGULATOR. CONTROL CONTRACTOR TO DISCONNECT AND DEMOLISH AUTOMATIC GAS VALVES AND MIRING. l°I DEMOLISH SECTION OF PIPE. FOR DIAGRAM SEE 3 IM5.0.. DEMOLISH Yi GAS VENT PIPE TO WALL, CAP AND ABANDON.. DEMOLISH ABANDONED WATER REGULATOR. CUT PIPE AT THE FLOOR, CAP AND ABANDONS. GIRLS: LOCKER; t2`'DiSa DH'WR 1 11Z���h _.. BOYS LOCKER- - 9'4"W 5FFs M PfEIE4-, 1040M13tl 2 •'`.si u4. w.. (Ry' 1 I " ,,: lCIH i,s' DWH-D1 1 2' 641.9-$.00.11P FLULkF Ikt'gE LAB (212 MSi1) THERMOS" .- 2 I:[31.F( \ 14 IIEIfr; TvRE.:rtil11. r 11irItIVE;'r'• i1: ii,);a TIn: •.i l Dti:" S€ NVlNG•I 11i;t{t"jl KEY NOTES: O PROVIDE DOMESTIC WATER HEATER. 1: STORAGE$01LERMANLITANKFACTURER. CIRCULATING PUMP PROVIDED WI BOILER BY ®:: 6" AL29-4C FLUE UP THRU ROOF. REUSE EXISTING OPENING. FLUSH ROOF WEATHER TIGHT. 1: f 4" AIR INTAKE TERMINATED IN BAILER ROOM. 0 PROVIDE GAS REGULATOR AND PIPING, RE -CONNECT REGULATOR VENT. PROVIDE INSULATED HOT WATER PIPING. SEE 21M5.0 FOR DIAGRAM. BOILER ROOM 0 000+® (ilRiltS LOOKER •I. 1hs'J-D1 DWH-D4 (TYPICAL)1. DWF1,03 DW -102 DWH-D1 4 KITCHEN DWH-A1 BUILDING A BOILER ROOM PLAN SCALE: 114"=1'-0" 0 1 I TR NSF 0 0 8' BOYS LOCKER 1 1 GAS FROMa L i Sri TYPICAL) PRV-D1 PRV-02 PRV-D3 }G•I_ P-RV;D4 I LL Et. I." IwJfT1:. LAS SHOWERS DVH -D1 BUILDING D MECHANICAL ROOM PLAN MEM 111•11111•111111 KEY NOTES: 0 PROVIDE INSTANTANEOUS DOMESTIC WATER HEATERS. SEE 4/M50 FOR DIAGRAM. C) 6" PVC AIR INTAKE UP THRU ROOF. RE -USE EXISTING' OPENING FLASH WEATHER TIGHT. 03 6' PVC VENT UP THRU ROOF. REUSE EXISTING OPENING FLASH WEATHER TIGHT. Q PROVIDE THERMOSTATIC MIXING VALVE . INSTALL STRICTLY IN ACCORDANCE *MANUFACTURER RECOMMENDATIONS. 0 PROVIDE INSULATED HOT WATER PIPING.ISEE 4/M5.0 FOR DIAGRAM. 0 PROVIDE COLD WATER CONNECTION. SEE41M5.0 QPROVIDE GAS REGULATOR AND PIPING, PROVIDE REGULATOR VENT AND ROUT TO OUTSIDE, FLASH AND WEATHERPROOF, © RE -CONNECT CONTROLS TO PROVIDE ENABLE! DISABLE` SIGNAL FRQh.1 BAS. INSTALL DWli ON WALL SHOWN HERE FOR CLARITY.,, 10 , PROVIDE PERMANENT WARNING LABEL "DO NOT SET BOILER WATER TEMPERATURE DISCHARGE ABOVE 140° F • FLUE PIPING DAMAGE MAY OCCUR". 11 COLD WATER PIPING AND HOT WATER PIPING SHALL BE INSTALLED IN " REVERSE RETURN' TO ENSURE EQUAL WATER FLOW THRU ALL HEATERS. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 11 2013 City of Tukwila BUILDING DIVISION PROJECT: For Th instry fe 4f Your Outsling SEATTLE: 5Q05 3RD AVOLUES PO BOX 24567 SEATTLE, WA 98134 1-800-669-6223 PORTLAND; 16790 NE MASON Si PORTLAND, OR 97230 503-331-0234 www.mckinst y.com TUKWILA SD S HO WALT E R MS.:. 4628 SOUTH 144TH STREET TOKVVILA, WA 98168 REGISTRATION; ISSUES: 11 1 18 1 2013 PERMIT SET NO. DATE DESCRIPTION McKINSTRY DIVISIO{ 1 ENGINEERING. DESIGNED BY: JESSICA SANDERS, DRAWN BY; CHRIS RILEY 3 CHECKED BY: KRISTINA SING. —� JOB NUMBER; C10300 DATE: 812012013' SCALE: AS SHOWN DWI -1.A1' KEY PLAN DWH.Dl SHEET TITLE: DEMOILITION PLAN AND FLOOR PLANS SHEET NUMBER: RECEIVED CITY OF TUKWILA NOV 21 2013 PERMIT CENTER M2.0 4 2" DCW TO FIXTURES- - - 2 Y" DHW FIXTURES (124 °F) HIGH•LOW'THERMOSTATIC VALVE i 120'F MIXED WATER DISCHARGE 3/4' DHWR FROMt-- FIXTURES PMP -A08. FINISHED FLOOR:;.. KEY NOTES Q DEMOLISH EXISTING DOMESTIC WATER HEATER, AND STORAGE TANK CIRCULATING PUMP, WATER STORAGE TANK TO REMAIN IN SERVICE. V DEMOLISH EXISTING FLUE. REUSE ROOF PENETRATION FOR REPLACEMENT EQUIPMENT 03 DEMOLISH EXISTING (2) REGULATORS AND GAS BRANCH. 0¢ CONTROL CONTRACTOR TO DISCONNECT CONTROL WIRING' 3° DCW FROM DOUBLE CHECK VALVE ASSEMBLY )1 GAS DHWR FROM KITCHEN DHW TO KITCHEN (1409F) DOMESTIC HOT WATER STORAGE TANK FLOOR DRAIN FINISHED FLOOR FLOOR DRAIN' PUP-mx1 j BUILDING A DOMESTIC WATER HEATER- DEMOLITION SCALE NOT TO SCALE 1Y"DOW 1 Y" aINWy DHWR. 4t G Ye GAS TO SECOND FLOOR SCIENCE LAB (20 MPH) 2" DCW FROM1 Y" GAS FROM METER„ DOUBLE CHECK /---1080 MBH, 2 PSI DELIVERY VALVEA8SEMBLY•—..,` -,, 1 Y' DHW ,., 1 'DHWR-–, CIRCULATING PUMP 10 GPM, 8' TDH, •104W, 120-1.60 ± PAIP-DDT I 1 U2'' GAS VALVE ®. KEY NOTES 2' DCW TO FIXTURES c - 2 Y` DHW TO _ FIXTURES (120 `F) 31'DHWRFROM (.1., FIXTURES HIGH-LOW THER1IOSTATIC VALVE 120°F MIXED WATER DISCHARGE EXISTING GAS SERVICE 750 MBH AT 2 PSI NEW GAS REQUIREMENTS 750 MBH AT 2 PSI - P- 131—III-- tlt— IU PMP -A08 3' DCW FROM DOUBLE CHECK VALVE ASSEMBLY , )1' GAS FROM KITCHEN 0110-1) 1 Y' DHW TO KITCHEN (140°F) KEY NOTES (j PRQVIDE MEWATER HEATER. SEE SCHEDULE.., 0 RE -CIRCULATING PUMP PROVIDED BY WATER HEATER MANUFACTUDORER-STIC 6" AL2F1-4C VENT UP THRU ROOF., • 4" AIR INTAKE TERMINATED IN BOILER ROOM. Q NEUTRALIZATION KIT BY UNIT MANUFACTURER. PRQVIDE INSULATED HOT WATER PIPING• O CONNECT EXISTING V VENT TO PRV VENT 0$ CONTROL CONTRACTOR TO RECONNECT CONTROL WIRING FOR EINABLEDISABLE SCHEDULE COMMAND C> STORAGE TANK TEMPERATURE SENSOR PROVIDED BY WATER HATER MANUFACTURER INSTALLED BY MECHANICAL WIRER BY CONTROL CONTRACTOR:' CD PRV-1 GAS VALVE PIPE FULL SIZE TO DRAIN W) 2 PIPE DIA AIR GAP ABV DRAIN. FINISHED FLOOR FLOOR DRAIN DOMESTIC HOT WATER STORAGE TANK BUILDING A DOMESTIC WATER HEATER DETAIL SCALE: NOT TO SCALE DHWR `J _��•.I b, ice+ A. GAS TO SECOND FLOOR SCIENCE LAB (20 MBH) 2" DCW FROM DOUBLE CHECK VALVE -, ASSEMBLY-- ,,,q"' 1 )./2* DHW Y' DHWR> 11113-azz2 EXISTING1 Y' GAS FROM METER. 1080 MBH, 2 PSI DELIVERY NEW GAS REQUIREMENTS 102D MBH, 2 PSI DELIVERY' `' / DEMOLISH EXISTING DOMESTIC WATER HEATER. Q DEMOLISH EXISTING FLUE REUSE ROOF PENETRATION FOR REPLACEMENT EQUIPMENT. Q DEMOLISH GAS PIPING INCLUDING REGULATOR AND MOTORIZED GAS VALVE. AND REGULATOR VENT , ROOF OPENING TO BE REUSED 0 DEMOLISH GAS VENT TO WALL, CAP AND ABANDON. CONTROL CONTRACTOR TO DISCONNECT CONTROL WIRING, CIRCULATING PUMP 10 GPM, 8`TDH,100W,120-1-60 3` CPVC VENT AND COMBUSTION AIR (TYPICAL) EXISTING GAS SERVICE 1060 MBH AT 2 PSI NEW GAS REQUIREMENTS 1000 MBH AT 2 PSI 1111'' V(TYPICAL) E DRAINPIPE W/ 2SIZPIPETO DI AIR GAPFULL ABV ORAIIAN (TYPICAL) .. - w ►--- , - 1r4" / 30'-200° GAS VALVE (TYP) 3M " (TYP) G PRY -D1 1 DWH-D4 DWH-D3 1 1 DWH-D21 250 MBH REVIEWED D !AOR CODE COMPLIANCE APPROVED DEC 11 2013 City of Tukwila BUILDING DIVISION KEY NOTES Q . PROVPROVIDEIDE ETE AERMOSTAWALL MOUNTED EDDOMESTIC WATER HEATER SEE TEMPERATURE 120°F- INSTALL STRICTLY ACCORDING TO:. MANUFACTURER RECOTICMMENDATIOMIXINGVALVE,NS, DISCHARGE 6" CPVC AIR INTAKE UP THRU ROOF, RE -USE EXISTING -. COMBUSTION AIR OPENING.F LASH ROOF WEATHER PROOF, . 6' CPVC VENT UP, THRU ROOF, REUSE EXISTING OPENING -FLASH ROOF WEATHER PROOF. C) IN LINE NEUTRALIZATION KIT BY UNIT MANUFACTURER, C) PROVIDE INSULATED HOT WATER PIPING 0, PROVIDE GAS PRESSURE REDUCING VALVE, AND r GS VENT, ROUT 1tENT UP THRU ROOF FLASH ROOF WEATHER PROOF, CONTROL CONTRACTOR TO RE -CONNECT CONTROL WIRING FOR ENABLEDISABLE SCHEDULE COMMAND- C) PROVIDE PERMANENT WARNING LABEL °D0 NOT SET BOILER WATER TEMPERATURE DISCHARGE ABOVE 140° F - FLUE PIPING DAMAGE MAY OCCUR" ip COLD WATER PIPING AND HOT WATER PIPING SHALL BE INSTALED IN `REVERSE RETURN' TO ENSURE EQUAL UAL WATER. FLOW THRU ALL HEATERS. FLOOR DRAIN ---' BUILDING D DOMESTIC WATER HEATER- DEMOLITION' SCALE: NOT TO SCALE FINISHED FLOOR BUILDING D DOMESTIC WATER HEATER DETAIL SCALE: NOT TO SCALE PROJECT' stry fe Of Your Hulliring SEATTLE: 5005 3RD AVENUE $` PO BOX 24667 SEATTLE, WA 98134 1-600-869-6223 PQRTI.AND:' 18790 NE MASON ST PRRTIlW , PR 97230 503-33.1-0234. www"mckinstry.aom. TUKWILA SD SHOWALTERMS 46 6 SOUTH 144TH STREET TU{41NILA,WA 98168... . ` _ REGISTRATION; ISSUES: 11 1 1812013 PERMIT SET NO: DATE. DESCRIPTION McKINSTRY DIVISION; ENGINEERING DESIGNED BY: JESSICA SANDERS DRAWN BY: CHRIS RILEY CHECKED BY:, KRISTINA SING J013 NUMBER: C10300 DATE: 912012013 SCALE: AS SHOWN SHEET TITLE: DIAGRAMS RECEIVED CITY OF TUKWILA SHEET NUMBER: NOV 2 7 2013 PERMIT.0:LATER, M5.0 FUEL GAS PIPING SEE M6.0 FOR SIZES. SHUTOFF COCK OR BALL VALVE WITHIN 6'•0' OF EQUIPMENT BOILER GAS REGULATOR VENT PIPED TO EXTERIOR - EACH ONE SEPARATELY, INCREASER AS REQUIRED DIRT LEG LOCATE AT THE BOTTOM OF VERTICAL PIPE: OO NOT LOCATE DIRT LEG IN HORIZONTAL PIPE, GAS PRESSURE REGULATOR W 1 VENT; SEE GAS REGULATOR SCHEDULE FOR CAPACITIES AND VENT SIZE;; REGULATOR TO BE INSTALLED AT LEAST 10 PIPE, DIAMETERS FROM BOILER MAIN GAS VALVE REDUCER AS REQUIRED NATURAL GAS REGULATING VALVE DETAIL SCALE NOT TO SCALE AIR INTAKE PIPE SEE EQUIPMENT SCHEDULE FOR DIAMETER REFER TO EQUIPMENT SCHEDULE FOR FLUE MATERIAL STORM COLLAR AIR INTAKE PROVIDE& MESH SCREEN TO COVER OPENING TALL CONE ROOF JACK FLASHING BY GC ROOF. STRUCTURE (TYP) ROOF CUT .& PATCH BY GC;:• NOTES: A. REFER TO MANUFACTURERS INSTRUCTIONS; FOR ADDITIONAL REQUIREMENTS, B. COMBUSTION AIR INTAKE TO BE A MINIMUM OF 3' AWAY FROM VENT DISCHARGE C, PROVIDE& SCREEN MESH. DWH - D1 THRU D-4 COMBUSTION INTAKE DETAIL SCALE NOT TO SCALE FLUE UP THRU ROOF TO EXIT CONE FLUE DAMPER SLOPE HORIZONTAL VENT SECTION DOWN TOWARDS BOILER WITH A MINIMUM 114' PER FOOT SLOPE SLOPE CONDENSATE DRAIN TOWARDS NEUTRALIZATION TANK WITH A MINIMUM 114; PER FOOT SLOPE. PROVIDE P -TRAP. FLUE CONDENSATE DISCHARGE CONNECTION ALTERNATE VENT PIPE SEE EQUIPMENT SCHEDULE FOR VENT DIAMETER REFER TO SOIL L.R SCHEDULE FOR FLUE MATERIAL - TALL CONE ROOF JACK FLASHING BY GC ROOF STRUCTURE (TYP)- ROOF CUT & PATCH BY GC MINIMUM PENETRATION SIZE VENT INTERNAL DIAMETER F4" DISCHARGE CAP VENT HEIGHT STORM COLLAR z NOTES: SLOPE HORIZONTAL VENT SECTION DOWN TOWARDS BOILER WITH A MINIMUM 1t4" PER FOOT SLOPE. FLUE CONDENSATE DRAIN THRU THE BOILER PAN. A. VENT CONE HEIGHT TO BE A MINIMUM OF 3'47 ABOVE ROOF LINE AND AT LEAST 2' HIGHER THAN ANY PORTION OF THE BUILDING WITHIN 10'. REFER TO MANUFACTURERS INSTRUCTIONS AND IFGC 503.6.4 "GAS VEN (TERMINATION` FOR ADDITIONAL REQUIREMENTS. C, VENT CONE HEIGHT TO BE A MINIMUM OF 4'4Y ABOVE COMBUSTION AIR INTAKE B, D, DISCHARGE CAP TO BE USED FOR VENT DISCHARGE OF HYDROTHERM BOILERS ONLY. CONFIRM VENT TERMINATION WITH OTHER MANUFACTURERS. DWH - Al FLUE VENT DISCHARGE DETAIL SCALE: NOT TO SCALE i�"-� SECURE MOUNTING BLOCK TO EXISTING :I CMU WALL MOUNTING BLOCK ( 23' PER EACH UNIT - PROVIDE MIN 6' BETWEEN UNITS) MOUNTING BRACKET BY UNIT MANUFACTURER • INSTALL PER MANUFACTURER INSTALLATION GUIDE. LOWER MOUNTING BLOCK ( 23' PER EACH UNIT - PROVIDE MIN 6' BETWEEN UNITS) SECURE UNIT LOWER BRACKET TO MOUNTING BLOCK DWH -D1THRU D4 INSTALLATION DETAIL SCALE: NOT TO SCALE VENT DISCHARGE PROVIDE; Y' MESH SCREEN TO COVERT OPENING VENT PIPE SEE EQUIPMENT SCHEDULE FOR VENT DIAMETER - REFER TO BOILER SCHEDULE FOR FLUE MATERIAL -------.- TALL CONE ROOF JACK FLASHING BY GG ROOF STRUCTURE (TYP)--d ROOF CUT & PATCH BY GC MINIMUM PENETRATION SIZE = VENT INTERNAL DIAMETER f4' SLOPE HORIZONTAL VENT SECTION DOWN TOWARDS HEATER WITH A MINIMUM 114" PER FOOT SLOPE, FLUE CONDENSATE DRAIN THRU THE BOILER PAN; NOTES; A. VENT HEIGHT TO BE A MINIMUM OF 3'-0' ABOVE ROOF LINE AND AT LEAST 2' HIGHER TITAN ANY PORTION OF THE BUILDING WITHIN 10'.' REFER TO MANUFACTURERS INSTRUCTIONS AND IFGC 503.6.4 "GAS VENT TERMINATION' FOR ADDITIONAL REQUIREMENTS. B. C. VENT HEIGHT TO BE A MINIMUM OF 4'-0' ABOVE COMBUSTION AIR INTAKE. D. CUT END OF VENT AT 46" (TO PREVENT BIRD NESTING), PROVIDE& SCREEN MESH. DWH - Di THRU D-4 FLUE VENT DISCHARGE DETAIL SCALE; NOT TO SCALE STRUCTURAL SEAL APPLIES TO DETAIL 6 ON THIS SHEET ONLY (N)Y2' DIA. HILTI TZ EXPANSION ANCHOR WITH 3)' EMBEDMENT, TYP. AT EACH CORNER OF BOILER FRAME (NOTE 2) IN) BOILER FRAME (N) MASON SUPER "W' PAD CONTRACTOR'S OPTION. (N) OR (E) CONCRETE HOUSE KEEPING PAD z NOTES: (E) CONCRETE SLAB, SEE NOTE 3. 1. IN) DENOTES "NEW, (5) DENOTES EXISTING, 2, SPECIAL INSPECTION REQUIRED FOR CONCRETE EXPANSION ANCHORS PER IBC 2009, CHAPTER 17, 3. CONCRETE HOUSEKEEPING PAO IS NOT REQUIRED IF SLAB THICKNESS EXCEEDS 4' MINIMUM_i 4. SEE MECHANICAL DRAWINGS FOR BOILER LOCATION, 5, INSTALL MASON TYPE SUPER PAD AT CONTRACTOR'S OPTION, COORDINATE WITH MECHANICAL DRAWINGS. 6, SEE DETAIL 71M5.0 FOR (N) HOUSEKEEPING, PAD. DWH -Al ANCHORAGE DETAIL SCALE NOT TO SCALE For Th instry ife Of Your Building SEATTLE 5005 3RD AVENUE $ PQ BOX 24567 SEATTLE, WA 98134 1-800..-66 6223 PORTLAND; 16790 NE MASON ST PQRT(IWI% oR 97230 503-331-0234 wmcmcklfwt y.com ..:PROJECT;. 1UKWILASD SHOWALTER MS 4628 SOUTH 144TH STREET TUKWILA, WA 98168 REGISTRAT ON ISSUES; 1111812012 PERMIT SET ND. DATE DESCRIPTION 1111111111.111011111111111111111111 McKINSTRY DMSION ENGINEERING DESIGNED BY: DRAWN BY: CHRIS RILEY CHECKED BY; KRISTINA SING JOB NUMBER; C10300 JESSICA SANDERS DATE 912.012018 SCALE; AS SHOWN' 0 2_2.2. v(t3,. SHEET TITLE,' DETAILS RECEIVED CITY OF TUKWILA NOV 2 7 2013 PERMIT CENTER SHEET NUMBER: M6.0