Permit M13-0224 - SOUTHCENTER PLACE - VERIZON - REPLACE WALL MOUNT A/C UNITS
SOUTHCENTER PLACE VERIZON 16400 SOUTHCENTER PKWY M13-0224 • City of Tukwila Department of Community Development �2 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: MECHANICAL PERMIT 2623049021 Permit Number: 16400 SOUTHCENTER PKWY 1 Project Name: SOUTHCENTER PLACE - VERIZON Issue Date: Permit Expires On: M13-0224 3/10/2014 9/6/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: LEGACY PARTNERS COMMERCIAL PO BOX 130639 , CARLSBAD, WA, 92013 TYLER VANDOOREN 7717 DETROIT AVE SW , SEATTLE, WA, 98106 MACDONALD/MILLER FAC SOL INC PO BOX 47983 , SEATTLE, WA, 98106 MACDOFS980RU / I ! Phone: (206) 768-3890 Phone: (206) 768-4180 Expiration Date: 1/3/2015 DESCRIPTION OF WORK: REPLACE (2) 4 -TON WALL MOUNT A/C UNITS WITH (2) NEW 5 -TON PACKAGED WLAL MOUNT A/C UNITS Valuation of Work: $12,500.00 Type of Work: REPLACEMENT Fuel type: GAS Fees Collected: $121.88 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: ®31 ( 0 I hI I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: j�,� Q Date: -3/ID lig Print Name: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 4: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://w\i%\•.Tukwila\VA.gov Project No. Date Application Accepted: Date Application Expires: 1 02 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: Tenant Name: King Co Assessor's Tax No.: 2623049021 16400 Southcenter Pkwy Tukwila, WA 98188 Suite Number: ROOF Floor: ROOF Southcenter Place - Verizon Wireless Shack PROPERTY OWNER Name: LEGACY PARTNERS COMMERICAL Address: 16400 Southcenter Pkwy City: TUKWILA State: WA Zip: 98188 CONTACT PERSON — person receiving all project communication Name: TYLER VANDOOREN Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-3890 Fax: (206) 768-3891 Email: tyler.vandooren@macmiller.com New Tenant: ❑ Yes ..No MECHANICAL.CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-4278 Fax: (206) 768-4279 Contr Reg No.: MACDOFS980RU Exp Date: 12/31/2013 Tukwila Business License No.: BUS -0100868 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: REPLACE (2) EXISTING 4 -TON WALL MOUNT AC UNITS WITH (2) NEW 5 -TON PACKAGED WALL MOUNT AC UNITS PER PLANS 12;500 Use: Residential: New ❑ Replacement Commercial: New ❑ Replacement Fuel Type: Electric m Gas ❑ E Other: F1:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 2 Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm 2 Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: P6-M( DARLA DOLL Print Name: Date: 12/02/2013 Day Telephone: (206) 768-4278 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip II:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT I QUANTITY I PAID $121.88 M13-0224 Address: 16400 SOUTHCENTER PKWY 1 Apn: 2623049021 $121.88 MECHANICAL $121.88 PERMIT FEE R000.322.100.00.00 $65.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R234 R000.322.102.00.00 $24.38 $121.88 Date Paid: Monday, December 02, 2013 Paid By: MACDONALD-MILLER FACILITY SOLU Pay Method: CHECK 3793 Printed: Monday, December 02, 2013 1:44 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OFTUKWILA.BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206).431-2451 . Pro'ect: , -t1ag,.WV 1 Type of Inspection: tI )/1L... . Address: ( LAA W f'R-2.14 wit (-( Date Called: Special Instructions: - Date Wanted: m' Reque„la►-:. tedVN ] e. Phone No. 0 (0L:2S X057 gl,A0pro'Ve—d per applicable. codes. Corrections required prior to approval. COMMENTS: E+��r 1 h rcveb. e fPIN`_r 0 1e. -}P / in/A/ Insp Date: 1 .`i �.c Ic�..a 3 ".z I� REINSECTION FEE REQUIRED. Prior to next inspection, fee must be . . .aid - 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. 1201 rust Avenue South, Suite 310 Seattle. Washington 98134 206.1024156 waw.tundapsahl.com I►• jp, _ _ ‘aatle STRUCTURAL CALCULATIONS MacDonald Miller VZN Mall Rats Bard H42 to H60 16400 Southcenter Pkwy Tukwila WA 98188 11/8/2013 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 2 2013 PERMIT CENTER 1201 1st Avenue South + Suite 310 + Seattle, WA 98134 + 206.402.5156 + www.lwo-se.com 1201 First Avena th Suite 310 SeaaleWaitlitng 98134 208.4O9P`5156fwwc'1�.1u"'adopsahl.com ,.x Site Address 16400 Southcenter Pkwy Tukwila WA 98188 Unit Being Installed VZN Mall Rats Wunit= 525 Attaching to 4" minimum cold formed studs spanning 10' maximum. Seismic Design Criteria (From USGS Hazard Calculator) SD5= 0.97 Unit attachment is OK per Appendix Calculations ATTACHMENT OPTIONS: Utiit:AttacF ment•w,/,CFMF Extension (if `.�,Atta Dliqto 14 GA 'cold formed 1r, and required) unit extension with (10) 3/8" Diameter A307 Bolts Attach 14 GA cold formed unit extension to existing building studs with (12) #12 screws, SW' 6serewsper stud. . Unit Attachment attached directly to metal studs Attach to existing CFMF studs with (10) #12 screws minimum UnitAttachment OK per appendix Calculations *.*Appendix has two sections including attachment when CFMF extension is required and a calulcation when the unit is installed directly to the CFMF studs of the existing structure. Note: MacDonald Miller has verified the new units are replacing existing heavier units weighing 552 lbs each. The new units will not be increasing load on roof framing below the metal shed and no check of the roof framing is required. T eqr� 1201 1st Avenue South + Suite 310 + Seattle, WA 98134 + 206.402.5156 + www.lwo-se.com 11/8/13 Design Maps SumnaryReport Mum Design Maps Summary Report User -Specified Input Report Title VZN Mall Rats Fri November 8, 2013 17:55:38 UTC Building Code Reference Document 2012 International Building Code (which utilizes USGS hazard data available in 2008) Site Coordinates 47.45531°N, 122.26184°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III -7,44k East Renton r pHighlands A mapqU' USGS-Provided Output S5 = 1.455 g Si = 0.542 g SMS = 1.455 g SM1 = 0.814 g S05 = 0.970 g Sol = 0.542 g For information on how the SS and Si values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.65 1.90 1.3S 1.20 1.05 0 0.90 H 0.75 0.60 0.45 0.30 0.19 0.00 0.00 0.20 MCER Response Spectrum 0.10 0.60 0.90 1.00 1.20 1.10 1.60 1.90 Period, T (sec) 2.00 1.10 1,00 0.l0 0.90 0.70 • 0.60 V1 • 0.50 0.40 0.30 0.20 0.10 0.00 0.00 0.20 Design Response Spectrum 0.40 0.60 0.90 1.00 1.20 1.10 1.60 1.90 Period. T ( sec) 2.00 Although this information is a product of the U.S. Geological Survey, we provide no warranty, expressed or implied, as to the accuracy of the data contained therein. This tool is not a substitute for technical subject -matter g eohazards.usgs.g oNdesig nmaps/us/summary php?template=minimal&latitude=47.455313&long itude=-122.261836&siteclass=3&riskcategory=0&edition=ibc-2... 1/2 APPENDIX - BARD/MARVAIR ATTACHMENT TO METAL STUDS WITH EXTENSION Project \ iPane) k Sheet Subject Unit Installation with Extension -.-_T L•• •w••• • Client /TC�m ( L j Page No. Designer Date www.lundopsahl.com 1 Tel: 206.402.5156 VE2T► ci_ �, �;�_ t•. �- A / u irr To City t,.JA dj' Es/ -41' z>lz ►6c_ f{< --.E /p Pecs-tAQIcam- uNti LSEICS{-T5 =� 1G ( L oNOEC.TDtt. t Mt- STUD .f$ _ 62110*- I -1A -g -vain= szs d� Foe mac* SELTI c►J vtek! .y qPM 4-), + 2��►. �r I /rP 41 l I ). O'3S�(ac 2-s/1� o + 2_4 >�=-I-d35- - L�, wE wi L.c' vEe-i FY AE.TVM- Sos DoE'S NOT �'x atop . Project Unit Installation with Extension Subject Sheet Clien: Designer o J L.1Q' A-4► 672,_ Page No. Date www.lundopsahl.com 1 Tel: 206.402.5156 NESLC 3 A --T- r -r 4 Ab Tet) /� � 4A -C), rP ree Crz►JSEe-v rT/VELY A SL* -fes ESMrG Arc. -TS :s VERTICAL 7E Ly. fc) -161/4 dS f3o4...TS TS eok.INEGT' /0 got-TS/0 13v�n �6�,-r DcAro -r - Et74 . T. : -T - L1 LSo" i Cz: Pyo1..ts> I 68 44/60‘.? L o. . , Se1SM I L, _ USE - A--'oT- $czt_T'S T' C iu EC'r 1 A>fCom•' 1 t lJti/T To Cary L`i r' A- l pme_ P PeN i,J (T te)* 6" 14.-6,Es*,L "). w tlz'� c EC%L A oA4:87012- FC. Cp MP es -15, 'or./ IGL = 1.2 ►r t'= . o2Z KL SSy rev- p5; F = ,6I7•ps 041. Project PilENbi)( Sheet Subject Unit Installation with Extension 7 Client #SeiCelrN'A-t D M l (1—EM. Designer Page No. Date www.lundopsahl.com 1 Tel: 206.402.5156 * C©jtlS TrvELy A-SSuME SEM F7.tG 4 L4 #L1-1, . - 12 SCee-e...)5 ; A"1"1"-Ac.4t Tc5 JPrL L 1 o.. ..,:nc::?k , ..3- (1 -as''') t* , 1 ,12ss /z 5ceE- tAihro et?. 1 I I crs Vert cM-'Y 00( /2 STs r-� a j 1 USS ASSuI--tc -eH //Z '&,`.r.. LIER- SS4a- APPENDIX - BARD/MARVAIR ATTACHMENT TO METAL STUDS DIRECTLY Project J IG VJ42L L /( �^ , . Subject 114A C C 4..4k - i F/p1//�l% c e - vA-kt, Gent _ __ _G_oK/AZ O 1.4a....t x Designer Sheet Page No. Date www.lundopsahl.com I Tel: 206.402.5156 7GAL-. / t i � �s 4/e__ vivir 7a C_R4-( uESFCr►.1 >ee_ Z z IBS t4Nir 4-Z 761-1-T SE ISM t C LaAt>s • 5-- 1.141-pos �P- /P 1 —mot-�c-r-may - 0 y� STvo! sPAr.JIJI rJ & 1 io` c 2 esr cA tyEs,►64.3 �eQ. -?& To Cie"' Ce✓idefn ‘ie" I , o3si -- -{ WL„ JEV%%FY ?re -TIAL Sas Ecc. yep THIS 6 CA) vee.$FY &) woos Lx, /.E./cam-0 rN1 S Project SENL l )< Sheet Subject ., [.,,*.L, 4 i Client i itlgip , Page No Designer Date www.lundopsahl_com Tel: 206.402.5156 -# Sc„ eZ'w4 be A , op''ti(1o`) cek, 11,T i4p ips fi . C344'9 1 .4cam-)5 /0Sce 'I ,L 1 'SNL tC_ 1y j2...) 1 /V c: srutbs mss off. Casr6-3 guns pK - -1 + C..*) [12,44 CPQ SCF -ll} CLIMATE CONTROL SOLUTIONS H -Series WALL-MOUNTTM AIR CONDITIONERS for Telecommunication and Equipment Structures H42 to H60A/L 1 -Stage Right & Left -Hand Control Panel HA/HL4 and 5 2 -Stage Right & Left -Hand Control Panel The Bard Wall -Mount Air Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor cooling at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as telecommunication structures and other equipment buildings. Factory or field Installed accessories are available to meet specific job requirements. 6a; c.c.s Standard Engineered Features.- All Models Aluminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. TWIn Blowers: Move air quietly. 1 -Stage models feature multispeed blower motors providing airflow adjustment for high and low static operation. 2 -Stage models have ECM motors. Motor overload protection is standard on all models. Alr Conditioner Compressor: Emerson scroll compressors are designed for increased efficiency, quieter operation and improved reliability for longer life. R -410A Refrigerant: Designed with R -410A (HFC) non -ozone depleting refrigerant In compliance with the Montreal protocol and 2010 EPA requirements. Galvanized 20 Gauge Zinc Coated Steel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand 1000 hours of salt spray tests per ASTM B117-03. Foll Faced Insulation: Standard on all units. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist In installation. Liquid Line Filter Drier: Standard on all units. Protects system against moisture. Compressor Control Module: Standard on all units. Built-in off - delay timer adjustable from 30 seconds to 5 minutes. 2 -minute on - delay if power interrupt. 120 -second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. Alarm output for alarm relay. Electrical Components: Are easily accessible for routine inspection and maintenance through side service panel opening. Features a lockable, hinged access cover to the circuit breaker. 24V Transformer: 75VA with circuit breaker Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed for all 3'h through 5 ton models. Filter Service Door Separate service door provides easy access for filter change. TWo-Inch. MERV 8 Alr Filters: Are standard equipment. Dirty Filter Switch: With alarm relay. Condenser Fan and Motor Shroud Assembly: Slides out for easy access. GREEN REFRIGERANT R -410A Built -In Circuit Breakers: Standard on all electric heat versions of single phase (2301208 volt). Circuit breaker option for 0 KW electric heat models. Slope Top: Standard feature for water run-off. Top Rain Flashing: Standard feature on all models. High & Low Pressure Switches are Auto -Reset: Standard on alt units. Built-in lock- out circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Low Ambient Control: Fan cycling LAC standard on all models. Screw -on fitting design for ease of service. 2 -Stage Step -Capacity Models Only 1 -Stage Models Only Optional Ventilation: Full -Flow Economizer"" with Enthalpy or Dry Bulb control. • Complies with efficiency requirements of ASHRAE/IESNA 90.1-2010. -Certified to ANSI/ARI Standard 390-2003 for SPVU (Single Package Vertical Units). • Intertek ETL Listed to Standard for Safety Heating and Cooling Equipment ANSI/UL 1995/CSA 22.2 No. 236-05, Fourth Edition. • Commercial Product - Not intended for Residential application. Step Capacity Compressor: Emerson step -capacity scroll compressors are designed for increased efficiency, quieter operation and improved reliability for longer life. Crankcase Heaters: Factory installed crankcase heaters are standard on 2 -stage models. This helps to ensure ease of start at low temperatures and improves compressor life. Start Kit: A PTCR compressor start assist (Positive Temperature Coefficient Resistor) is standard on all -A single-phase 2 -stage models to increase system reliability. This hetes to ensure compressor starts at adverse conditions by increasing the compressor starting torque. Suction Line Accumulator: Standard on 2 -stage models. ECM Indoor Blower Motor. Features a variable speed motor providing super -high efficiency, low sound levels and soft -start capabl60es. The motor is self- adjusting to provide the proper airflow rate for the staged capacity, and for higher static pressure in ducted installations without user adjustment or wiring changes. C rote US Form No. S3458-313 Supersedes S3458-712 Page 1 0118 Capacity and Efficiency Ratings — 1 -Stage Compressors MODELS Right -Hand Controls Left -Hand Controls H42A2 H48A2 H60A2 H42L2 H48L2 H60L2 Cooling Capacity BTUH O 40,000 48,500 55,000 40,000 48,500 55,000 EER 9.50 9.00 9.00 9.50 9.00 9.00 CD Capacity is certified In accordance with ANSI/ARI Standard 390-2003. ® EER = Energy Efficiency Ratio and is certified in accordance with ANSI/ARI Standard 390-2003. An ratings based on fresh air Intake being 100% closed (no outside air introduction). Capacity and Efficiency Ratings — 2 -Stage Step CapacityCompressors MODELS Right -Hand Controls Left -Hand Controls HA4S3 HA5S3 HL4S2 HL5S2 1100 Cooling Capacity BTUH, 2nd Stage Operation 46,000 56,500 46,000 56,500 EER 2nd Stage Operation OO 11.2 10.1 11.2 10.1 Rated CFM (Wet Coil) 1500 1700 1500 1700 Cooling Capacity BTUH, 1st Stage Operation 34,000 40,000 34,000 40,000 EER 1st Stage Operation O 11.6 10.8 11.6 10.8 Rated CFM (Wet Coil) 1100 1300 1100 1300 IPLV ® 15.2 14.3 15.2 14.3 m Certified in accordance with ANSI/ARI Standard 390-2003 for single package vertical units. • EER = Energy Efficiency Ratio - BTU/WATT efficiency. CD Integrated Part Load Value - BTU/WATT efficiency and certified in accordance with ANSI/ARI Standard 390-2003. All capacity, efficiency and cost of operation information is based on operation with fresh air cover plate. Cover plate is recommended for use to obtain maximum energy efficiency where ventilation air Is not required. Indoor Blower Performance — CFM at Rated Volts 1 -Stage Compressor Models ESP in H2O H42A2 / H42L2 H48A2 / H48L2 H60A2/H60L2 High Speed Low Speed Dry/Wet Coil Dry/Wet Coil High Speed Low Speed Dry/Wet Coil Dry/Wet Coil High Speed Low Speed Dry/Wet Coil Dry/Wet Coil .05 1635/1550 1450/1400 1635/1550 1450/1400 2000/1800 1465/1200 .15 1500/1400 1350/1300 1500/1400 1350/1300 1875/1700 -/- .25 1370/1285 1300/1175 1370/1285 1300/1175 1775/1600 -1- .35 1250/1150 -1- 1250/1150 -1- 1650-1475 -1- Above data Is with Y pleated filter. See installation Instructions for maximum ESP Information on various KW application. Speeds marked 'bold' above are Factory Connected Indoor Blower Performance MODELS — CFM (0.00" Blower Only - 0.80" 1120) 1st Stage Cooling ® 2 -Stage 2nd Stage Cooling Compressor 5-10 KW Electric Heat Models 15-20 KW Electric Heat HA4S3 HL4S2 825 1100 1500 1100 1500 HA5S3 HL5S2 850 1300 1700 1100 1500 O These systems contain Variable Speed ECM Motor, which maintains airflow across static range at dry and wet coli conditions. Forth No. S3458-313 Supersedes 53458.712 Page 2 of 18 Unit Specifications MODELS MODELS 1 -Stage Compressor H42A2 H42L2 H48A2 H48L2 H60A2 H60L2 Electrical Rating - 60 Hz 230/208-1 230/208-1 230/208-1 Operating Voltage Range 197-253 197-253 197-253 Compressor - Circuit A Voltage 230/208-1 230/208-1 230/208-1 Rated Load Amps 15.9/17.8 21/23.5 21.9/24.9 Branch Circuit Selection Current 19.9 25 26.3 Lock Rotor Amps 109/109 134/134 134/134 Compressor Type Scroll Scroll Scroll Fan Motor & Condenser Fan Motor- HP -- RPM 1/3 - 825 - 2 1/3 - 825 - 2 1/3 - 825 - 2 Fan Motor - Amps 2.5 2.5 2.5 Fan - DIA/CFM 24" - 2600 24" - 2600 24" - 2600 Blower Motor & Evap. Blower Motor - HP - RPM - SPD 1/2-1070-2 1/2-1070-2 1/2-1070-2 Blower Motor - Amps 3.3 3.3 3.3 CFM Cooling (Rated -Wet -Coil) 1400 1550 1700 Filter Sizes (inches) STD. 20x30x2 20x30x2 20x30x2 Shipping Weight - LBS. * 460 465 485 * For factory Installed economizers add 51 tbs. Clearances Required for ,Service Access and Adequate Condenser Inlet Airflow MODELS LEFT SIDE RIGHT SIDE H42 - 60A 20" 20" H42 - 60L 20" 20" HA4-5S, HL4-5S 20" 20" NOTE: For side by side installation of two (2) "A" models there must be 20" between units. This can be reduced to 15" by using an "1" model (left side compressor and controls) for the left unit and "A" (right side compressor and controls) for right unit. 2 -Stage Compressor HA4S3 HL4S2 HA583 HL5S2 230/208-1 197-253 230/208-1 16.1/19.1 21.2 96/96 Scroll 1/3-825-2 2.5 24" - 2800 3/4 -Variable 6.8 1500 20x30x2 530 230/208-1 197-253 230/208-1 21.9/26.6 26.6 118/118 Scroll 1/3-825-2 2.5 24" - 2800 3/4 -Variable 6.8 1700 20x30x2 530 Minimum Clearances Required to Combustible Materials SUPPLY MR MODELS (D DUCT FIRST CABINET THREE FEET H42 - 60A 1/4" 0" H42 - 60L 1/4" 0" HA4-5S, HL4-5S 1/4" 0" m Refer to the Installation Manual for more detailed information. Form No. S3458-313 Supersedes 53458.712 Page 3 of 18 Ventilation System Packages (H42 - 60A, H42 - 60L) 1 -Stage Compressor Models Bard Wall -Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a blank off plate as the standard ventilation package. BLANK OFF PLATE - BOP STANDARD A blank off plate Is Installed on the Inside of the service door. It covers the air Inlet openings which restricts any outside air from entering Into the unit. Tho blank off plate should be utilized In applications where outside air Is not required to be mixed with the conditioned air. Economizer - JADE Series FULL FLOW ECONOMIZER"' - ECONWMT - JADE Series OPTIONAL The built-in economizer system Is Internally mounted behind the service door and allows outdoor air to be Introduced through the air Inlet openings. The amount of outdoor air varies In response to the system controls and settings defined by the end user. 11 Includes a built -In exhaust air damper. The economizer Is designed to provide "free cooling' when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This In tum provides lower operating costs, while extending the life of the compressor. ECONWM Design Features: • Designed to deliver 100% of cooling rated CFM • Honeywell Direct Drive HI -Torque Actuator Nu flukege required • Simple single blade design • Positive shut-off with non-stick gaskets • Honeywell JADE electronic economizer module with precision settings end diagnostics • Dry Bulb (Factory Option T) or Enthalpy (Factory Option W) economizer versions • Electronic Dry Bulb or Enthalpy sensor • Economizer fail alarm circuit • Air Intake Hood with Mist Eliminator (supplied with unit, knocked down with minor field assembly) • Economizers can be factory or field installed MV4000-Serles Lead/Lag Controller for use with JADE -Series Full -Flow Economizer"' Form No. S3458-313 Supersedes S3458-712 Page 4 of 18 SPECIFICATIONS/FEATURES FOR MV4000-B CONTROLLER MV4000 Basic Controller •Input power: 18-32 VAC, 60/50Hz, power is supplied from A/C #1 and/or A/C #2 •Isolation circuitry: no line or low voltage phasing required 'Backup power: connection for -24 VDC or -48 VDC (-20 to -56V) maintains microprocessor operation, front panel indication & alarm relay operation during commercial power outages. *Digital display: 4 -character LCD •Temperature display: F or C •HVAC outputs: Form A (NO) relays (IA @ 24 VAC) •Cooling control stages: 2 for each A/C unit (4 total) when configured for economizers l for each A/C unit (2 total) when configured for no economizers *Heating Control stages: 1 for each A/C unit •Dehumidification circuit: requires optional humidity controller as input signal •Operating temperature range: 0 to 120F (-18 to 49C) •Storage temperature range: -20 to 140F (-29 to 60C) •Temperature accuracy: +/- IF from 60-85F (16-30C) +/- 1% outside 60-85F •Lead/lag changeover time: 0 to 30 days •Timing accuracy: +/- 1% •inter -stage time delay: 10 seconds between stages •Inter -stage differential: Stage 1 to 2 - Range 2-6F, default is 4 Stage 2 to 3 - Range 2-3F, default is 2 Stage 3 to 4 - Range 2-3F, default is 2 •On -Off differential: 2F (iC) is standard, 41? (3C) when "excessive cycling" mode is enabled •Cooling set point range: 65 to 90F (18.3 to 32.2C). Default setpoint 77F •Comfort setting -Cooling 72F (22C), Fleming 68F(20C), for 1 hour •Dead band (difference between cooling and heating set points): 2F to 40F (1.1C to 22.2C) •Fire/smoke interface: standard NC circuit jumper, remove for connection to building system control, shuts down both A/C units immediately •Generator shut -down circuit option for economizers •Lead/Lag switching option •2nd compressor lockout option •Memory: EEPROM for set point and changeable parameters (maintains settings on power loss) •Space temperature sensors: 1 local is standard, will accept up to 2 optional 25' remote sensors, Bard part number 8612-023. When multiple sensors are used, temperatures are averaged • Controller Enclosure: 20 -gauge pre -painted steel, 9.25"W x 20.875"H x 4.00"D, hinged cover, twenty four (24) .875" diameter electrical knockouts • LEDs for basic controller: Lead unit, Cooling stages 1 through 4, Heating Stages 1 — 4, Dehumidification operation • Six (6) Push-button controls: On/Off switch -Change lead unit -Increase & Decrease set points -Program/ Save -Comfort. •MV4000-BC Controller with CB4000 Communication Board for remote Ethernet access also available. •CB4000 Communication Board can also be field installed to base MV4000-B if not originally equipped. NOTE: MV4000-B Controller can not be used with SPYDER-Series economizers Refer to Installation Instructions 2100-571 for complete details. Ventilation System Packages (H42 - 60A, H42 - 60L) 1 -Stage Compressor Models Bard Wall -Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. All units are equipped with a blank off plate as the standard ventilation package. BLANK OFF PLATE - BOP STANDARD A blank off plate is installed on the inside of the service door. It covers the air inlet openings which restricts any outside air from entering into the unit. The blank off plate should be utilized In applications where outside sir is not required to be mixed with the conditioned air. Economizer - SPYDER Series FULL FLOW ECONOMIZERT'r • ECONHMT - SPYDER Series OPTIONAL Tho built -In economizer system is internally mounted behind the service door and allows outdoor air to be Introduced through the air Inlet openings. The amount of outdoor air varies In response to the system controls and settings defined by the end user. It includes a built-in exhaust alr damper. The economizer is designed to provide 'free cooling" when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in tum provides lower operating costs, while extending the life of the compressor. ECONWM Design Features: • Regulated based on DC amp -draw on the battery storage system. Requires current transducer to measure total OC amp draw (supplied by others). 0-10 VDC signal required. • Designed to deliver 100% of cooling rated CFM • Honeywell Direct Daive HI-Turquu Ae tuatur • No linkage required • Simple single blade design • Positive shut-off with non-stick gaskets • Economizer fail alarm circuit • Honeywell SPYDER electronic economizer modulo with precision settings and diagnostics • Dry Bulb (Factory Option F) or Enthalpy (Factory Option G) economizer versions • Electronic Dry Bulb or Enthalpy sensors • Air Intake Hood with Mist Eliminator (supplied with unit, knocked down with minor field assembly) • Can be factory Installed only MD4000-Series Lead/Lag Controller for use with SPYDER-Series Full -Flow Economizer"' NOTE: This MD4000 Controller is required for SPYDER-Series DC load controlled economizers that are regulated based on DC amp -draw on the battery storage system. Requires current transducer to measure total DC amp -draw (supplied by others). 0-10 VDC signal required, factory program based on 0-500A current transducer, can be changed as required for anywhere up to 0-1000A. SPECIFICATIONS/FEATURES FOR •Lead/Lag switching option MD4000-B CONTROLLER •2nd compressor run option MD4000 Basic Controller •Memory: EEPROM for set point and changeable •Input power: 18-32 VAC, 60/50Hz, power is supplied parameters (maintains settings on power loss) from A/C 01 and/or A/C #2 •Space temperature sensors: 1 local is standard, will •Isolation circuitry: no line or low voltage phasing required accept up to 2 optional 25' remote sensors, Bard part •Backup power: connection for -24 VDC or -48 VDC (-20 number 8612-023. When multiple sensors are used, to -56V) maintains microprocessor operation, front panel temperatures are averaged indication & alarm relay operation during commercial •Controller Enclosure: 20 -gauge pre -painted steel, power outages. 9.25"W x 20.875"H x 4.00"D, hinged cover, twenty •Digital display: 4 -character LCD four (24) .875" diameter electrical knockouts •Temperature display: F or C -LEDs for basic controller Lead unit, Heating Stages 1-4 •HVAC outputs: Form A (NO) relays (1 A @ 24 VAC) •Six (6) Push-button controls: On/Off switch -Change •Cooling control stages: lead unit -Increase & Decrease set points -Program/ 2 for each A/C unit (4 total) Save -Comfort. •Heating Control stages: •MD4000-BC Controller with CB4000 Communication 1 for each A/C unit Board for remote Ethernet access also available. •Operating temperature range: 0 to 120F (-18 to 49C) •CB4000 Communication Board can also be field •Storage temperature range: -20 to 140F (-29 to 60C) installed to base MD4000-8 if not originally equipped. Qt evesERrro"oraa CONTROLLER w leer •Temperature accuracy: +1- IF from 60-85F (16-30C) +/- I% outside 60-85F •Lead/lag changeover time: 0 to 30 days •Timing accuracy: +/- 1% •Inter -stage time delay: 10 seconds between stages •On -Off differential: 2F (IC) is standard, 4F (3C) when "excessive cycling" mode is enabled •Comfort setting, Heating 68F(20C), for 1 hour •Dead band (difference between cooling and heating set points): 2F to 40F (l.1C to 22.2C) •Fire/smoke interface: standard NC circuit jumper, remove for connection to building system control, shuts down both A/C units immediately •Generator shut -down circuit option for economizers NOTE: MD4000-B Controller can not be used with JADE -Series economizers Refer to installation Instructions 2100-574 for complete details. Form No. S3458-313 Supersedes S3458-712 Page 5 0118 Electrical Specifications 1 -Stage Compressor Models MODEL Rated Votts & Phase No. FIoId Powor Circuits Single Circuit Dual Circuit m MinimumField Circuit Ampacity O) Maximum External Fuse or Ckt. Brkr. m Field Power Wire Size Ground Wire a) Minimum Circuit Ampacity , Q1 Maximum External Fuse or Ckt. Breaker Power Wire Size Ground Wire Sys Ckt. A Ckt. 13 CktA CktB CkLA Ckt.B CktA Ckt. B 1442A2 -A00. AU H421.7 A05 A10 A15 230/208-1 1 1 1 1 or 2 32 32 58 84 50 50 60 90 8 8 8 4 10 10 10 8 59 26 60 30 6 10 10 10 H48A2-A00, AOZ H481.2 A05 A10 A15 230/2081 1 1 1 1 or 2 39 39 58 84 50 50 60 90 8 8 6 4 10 10 10 8 69 28 60 30 8 10 10 10 H60A2•A00, AOZ H60L2 A05 A10 A15 230208-1 1 1 1 1 or 2 42 42 60 88 60 60 60 90 8 8 6 4 10 10 10 a 59 26 60 30 6 10 10 10 4) Maximum size of the lime delay fuse or HACR type circuit breaker for protection of Bald wiring conductor. m Based on 75C copper wire. All wiring must conform to the National Electrical Coda and eU local codes. 01 Those 'Minimum Circuk Ampadiy values aro to be used for sizing the field power ccndudora. Refer to the National Electrical coda (latest version). Article 910 for power conductor sizing. Caution: When more than one field power draft Is run through one conduit, the conductors must bo daratod. Pay special attention to note 8 of Table 310 regarding Awpadty Adjustment Factors when more than three (3) current carrying conductors aro in a raceway. IMPORTANT: White this electrical data Is presented ase guide, it is important to afectrically conned property sized fuses & conductor Mires in accordance with the National Electrical Code 8 all local codes. Electrical Specifications 2 -Stage Compressor Models MODEL Rated Volts & Phase No. Field Power Circuits Single Clrcult Dual Circuit CD Minimum Circuit Ampacity Maximum External Fuse or Ckt. Brkr. m Field Power Wire 8)ze m Ground Wire Minimum Circuit Ampacity 0 Maximum External Fuse or Ckt. Breaker Field Powor Wiro Size m Ground Wire Size Ckt A Ckt B CkLA' Ckt. CkLA Ckt B CkLA Ckt 8 HA4S3K -AOZ HL4S2K •A05 •A08 -A10 -A15 230/208-1 1 1 1 1 or 2 1or2 38 38 53 63 89 45 45 60 70 90 8 8 6 6 3 10 10 10 8 8 37 37 26 52 45 45 30 60 8 8 10 6 10 10 10 10 HA5S3K •A02 HL5S2K -A05 -A08 -A10 -A15 230208-1 1 1 1 1 or 2 1 or 2 44 44 53 63 89 50 60 60 70 90 8 8 6 6 3 10 10 10 8 8 44 44 26 52 50 50 30 60 8 6 10 8 10 10 10 10 4) Maximum size of the Ilene delay fuse or HACR type circuit breaker for protection of field wiring conductors. O Based on 75C copper wire. All wiring must conform to the National Electrical Code and all local codas. m These 'Minimum Circuit Ampacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), Article 310 for power conductor sizing. Caution: When more than one field power drarlt is run through one conduit. the concluders must be derated. Pay special attention to note 8 of Table 310 regarding Ampacity Adjustment Factors when more than three (3) current carrying conductors aro in a raceway. IMPORTANT: Whig this electrical data Is presented as a guide, tt B inportant to electrically conned property sized fuses 8 conductor wires In accordance with the National Electrical Code 8 all local codas. Form No. S3458-313 Supersedes S3458.712 Page 6 of 16 Heater Packages— Field Installed 1 -Stage Compressor Models • Designed for adding Electric Heat to 0 KW Units • Circuit Breaker Standard on 230/208V Models Air Conditioner Models -A00 Models 230/208-1 Heater Model # KW KW EHWA05-A05 5 H42A2 H48A2 EHWA05-A10 10 HA4S3 EHWA05-A15 15 17,065 EHWA60-A05 5 H60A2 EHWA05-A10 10 33.3 EHWA05-A15 15 • ETL US & Canada Listed . Air Conditioner Models - 7A00 Models 230/208-1 Heater Model # KW KW EHWA05-A05L 5 H42L2 H48L2 EHWA05-A10L 10 HA4S3 EHWA05-A151 15 17,065 EHWA05-A05L 5 H60L2 EHWA05-A10L 10 33.3 EHWA05-A15L 15 Heater Packages Field installed 2 -Stage Compressor Models • Designed for adding Electric Heat to 0 KW Units • Circuit Breaker Standard on 230/208V Models Air Conditioner Models -A00 Models 230/208-1 Heater Model # KW KW EHWA4S-A05 5 KW EHWA5S-A08 8 HA4S3 5.0 20.8 17,065 EHWA4S-A10 10 12,799 EHWA4S-A15 15 33.3 EHWA5S-A05 5 28.8 EHWA5S-A08 8 HA5S3 EHWA5S-A10L 10 7.50 EHWA5S-A10 10 15.0 EHWA5S-A15 15 • ETL US & Canada Listed Air Conditioner Models -A00 Models 230/208-1 Heater Model # , KW KW EHWA4S-A05L 5 KW EHWA5S-A08L 8 HL4S2 5.0 20.8 17,065 EHWA4S-A1OL 10 12,799 EHWA4S-A15L 15 33.3 EHWA5S-A05L 5 28.8 EHWA5S-A08L 8 HL5S2 EHWA5S-A10L 10 7.50 EHWA5S-A15L 15 Electric Heat Table — Refer to Electrical Specifications At 240V (1) for Availability by Unit Model At 208V (1) Nominal KW KW 1 -Ph Amps Btuh KW 1 -Ph Amps Btuh 5.0 5.0 20.8 17,065 3.75 18.0 12,799 8.0 8.0 33.3 27,304 6.00 28.8 20,478 10.0 10.0 41.7 34,130 7.50 36.1 25,598 15.0 15.0 62.5 51,195 11.25 54.1 38,396 m These electric heaters are available in 230/208V units only. Form No. 83458-313 Supersedes S3458.712 Page 7 of 16 H42A/H42L Cooling Performance Data Model Number Indoor DB/WB % RH Cooling Performance Data Outdoor Temperature °F 75 85 95 105 115 H42A2 H42L2 80/87.0 51.1 Total Cooling Btu/H 45900 43100 40500 38100 35700 Sensible Cooling Btu/H 33100 32300 31300 30100 28600 Nominal Tons Sensible 2.76 2.69 2.81 2.51 2.38 Sensible Heat Ratio (%) 0.72 0.75 0.77 0.79 0.80 H42A2 H42L2 77/64.5 51.1 Total Cooling Btu/H 40960 41515 39275 36860 34485 Sensible Cooling Btu/H 32240 34065 33175 32000 31335 Nominal Tons Sensible 2.69 2.84 2.76 2.87 2.61 Sensible Heat Ratio (%) 0.79 0.82 0.84 0.87 0.91 H42A2 H42L2 77/62.8 45.4 Total Cooling Btu/H 41950 40250 38100 35800 33460 Sensible Cooling Btu/H 37200 34100 33410 32475 31305 Nominal Tons Sensible 3.10 2.84 2.78 2.71 2.61 Sensible Heat Ratio (%) 0.89 0.85 0.88 0.91 0.94 H42A2 H42L2 77/61.2 40.1 Total Cooling Btu/H 40960 39175 37080 34910 32840 Sensible Cooling Btu/H 37190 36430 35215 34160 32840 Nominal Tons Sensible 3.10 3.04 2.93 2.85 2.74 Sensible Heat Ratio (%) 0.91 0.93 0.95 0.98 1.00 H42A2 H42L2 77/59.6 35.1 Total Cooling Btu/H 40265 38350 36620 34800 32830 Sensible Cooling Btu/H 39060 38350 36820 34800 32830 Nominal Tons Sensible 3.26 3.20 3.05 2.90 2.74 Sensible Heat Ratio (%) 0.97 1.00 1.00 1.00 1.00 H42A2 H42L2 77/58.0 30.2 Total Cooling Btu/H 40050 38330 36600 35040 32815 Sensible Cooling Btu/H 40050 38330. 38600 35040 32815 Nominal Tons Sensible 3.34 9.19 3.05 2.92 2.73 Sensible Heat Ratio (%) 1.00 1.00 1.00 1.00 1.00 APPLICATION NOTE: All Bard units are designed to be able to reduce humidity levels should the condition exist for any reason, and then will automatically transition up to 100% sensible capacity as the building attains lower relative humidity (below 40%) due to extended runtime required for the waste heat management from the equipment and shelter load. HVAC units that are designed for high sensible heat ratios (above .90) at standard AHRI rating conditions (95F Outdoor DB and 80F DB/67F WB Indoor) may not be able to manage higher humidity levels that may occur and reduce to acceptable levels when properly sized. Forth No. S3458-313 Supersedes S3458-712 Page 8 of 16 H48A/H48L Cooling Performance Data Model Number Indoor DB/WB% RH Cooling Performance Data Outdoor Temperature °F 75 85 95 105 115 H48A2 H48L2 80/67.0 51.1 Total Cooling Btu/H 55000 52500 49500 46100 42200 Sensible Cooling Btu/H 38100 37300 36100 34600 32700 Nominal Tons Sensible 3.18 3.11 3.01 2.88 2.73 Sensible Heat Ratio (%) 0.69 0.71 0.73 0.75 0.77 H48A2 H48L2 77/64.5 51.1 Total Cooling Btu/H 50090 47600 45125 42500 39750 Sensible'Cooling Btu/H 39900 39000 37880 36840 35780 Nominal Tons Sensible 3.33 3.25 3.16 3.07 2.98 Sensible Heat Ratio (%) 0.80 0.82 0.84 0.87 0.00 H48A2 H48L2 77/62.8 45.4 Total Cooling Btu/H 48530 46120 43600 41070 38400 Sensible Cooling Btu/H 42650 41625 40570 37760 36600 Nominal Tons Sensible 3.55 3.47 3.38 3.15 3.05 Sensible Heat Ratio (%) 0.88 0.90 0.93 0.92 0.95 H48A2 H48L2 77/61.2 40.1 Total Cooling Btu/H 47150 44860 42475 40025 37660 Sensible Cooling Btu/H 43000 41870 40730 39020 37680 Nominal Tons Sensible 3.58 3.49 3.39 3.25 3.14 Sensible Heat Ratio (%) 0.91 0.93 0.96 0.97 1.00 H48A2 H48L2 77/59.6 35.1 Total Cooling Btu/H 45960 43975 41870 40840 40040 Sensible Cooling Btu/H 44860 43975 41870 40840 40040 Nominal Tons Sensible 3.74 3.66 3.49 3.40 3.34 Sensible Heat Ratio (%) 0.98 1.00 1.00 1.00 1.00 H48A2 H48L2 77/58.0 30.2 Total Cooling Btu/H 45640 43760 41850 39820 37825 Sensible Cooling Btu/H 45640 43762 41850 39820 37625 Nominal Tons Sensible 3.80 3.65 3.49 3.32 3.14 Sensible Heat Ratio (%) 1.00 1.00 1.00 1.00 1.00 APPLICATION NOTE: All Bard units are designed to be able to reduce humidity levels should the condition exist for any reason, and then will automatically transition up to 100% sensible capacity as the building attains lower relative humidity (below 40%) due to extended runtime required for the waste heat management from the equipment and shelter load. HVAC units that are designed for high sensible heat ratios (above .90) at standard AHRI rating conditions (95F Outdoor DB and 80F DB/67F WB Indoor) may not be able to manage higher humidity levels that may occur and reduce to acceptable levels when properly sized. Form No. S3458-313 Supersedes S3458-712 Page 9 0118 H6OA/H6OL Cooling Performance Data Model Number Indoor DB/WB % RH Cooling Performance Data Outdoor Temperature °F 75 85 95 105 115 H60A2 H60L2 80/67.0 51.1 Total Cooling Btu/H 60800 58200 55000 51300 47000 Sensible Cooling Btu/H 42400 41300 40000 38500 36800 Nominal Tons Sensible 3.53 3.44 3.33 3.21 3.07 Sensible Heat Ratio (%) 0.70 0.71 0.73 0.75 0.78 H60A2 H60L2 77/84.5 51.1 Total Cooling Btu/H 58875 56000 52995 49810 46000 Sensible Cooling Btu/H 42475 41315 40000 38390 37050 Nominal Tons Sensible 3.54 3.44 3.33 3.20 3.09 Sensible Heat Ratio (%) 0.72 0.74 0.75 0.77 0.81 H60A2 H60L2 77/62.8 45.4 Total Cooling Btu/H 56860 53945 51100 48095 44900 Sensible Cooling Btu/H 45430 43670 43200 41445 39750 Nominal Tons Sensible 3.79 3.64 3.60 3.45 3.31 Sensible Heat Ratio (%) 0.80 0.81 0.85 0.86 0.89 H60A2 H60L2 77/61.2 40.1 Total Cooling Btu/H 54940 52290 49430 46425 43440 Sensible Cooling Btu/H 47475 46555 45235 43550 42120 Nominal Tons Sensible 3.96 3.88 3.77 3.63 3.51 Sensible Heat Ratio (%) 0.86 0.89 0.92 0.94 0.97 H60A2 H60L2 77/59.6 35.1 Total Cooling Btu/H 53280 50650 47915 45300 42910 Sensible Cooling Btu/H 50190 48875 47185 45300 42910 Nominal Tons Sensible 4.18 4.07 3.93 3.78 3.58 Sensible Heat Ratio (%) 0.94 0.96 0.98 1.00 1.00 H60A2 H60L2 77/58.0 30.2 Total Cooling Btu/H 52025 49795 47600 45285 42895 Sensible Cooling Btu/H 52025 49795 47600 _ 45285 42895 Nominal Tons Sensible 4.34 4.15 3.97 3.77 3.57 Sensible Heat Ratio (%) 1.00 1.00 1.00 1.00 1.00 APPLICATION NOTE: All Bard units are designed to be able to reduce humidity levels should the condition exist for any reason, and then will automatically transition up to 100% sensible capacity as the building attains lower relative humidity (below 40%) due to extended runtime required for the waste heat management from the equipment and shelter load. HVAC units that are designed for high sensible heat ratios (above .90) at standard AHRI rating conditions (95F Outdoor DB and 80F DB/67F WB Indoor) may not be able to manage higher humidity levels that may occur and reduce to acceptable levels when properly sized. Forth No. 53458-313 Supersedes 63458-712 Page 10 0118 HA4S/HA4L Cooling Performance Data Model Number Indoor DB/WB % RH Full Load (Stage 2) Cooling Performance Data Outdoor Temperature 'F 75 85 95 105 115 HA4S HL4S 80/67.0 51.1 Total Cooling Btu/H 53600 49800 48000 42950 39900 Sensible Cooling Btu/H 37600 35800 34000 32900 31800 Nominal Tons Sensible 3.13 2.98 2.83 2.74 2.65 Sensible Heat Ratio (%) 0.70 0.72 0.74 0.77 0.80 HA4S HL4S 77/64.5 51.1 Total Cooling Btu/H 49385 46845 44135 41500 38475 Sensible Cooling Btu/H 35460 34690 33575 32965 31285 Nominal Tons Sensible 2,96 2.89 2.80 2.75 2.61 Sensible Heat Ratio (%) 0.72 0.74 0.76 0.79 0.81 HA4S HL4S 77/82.8 45.4 Total Cooling Btu/H 47640 45135 42440 39920 38910 Sensible Cooling Btu/H 37950 38980 35635 34880 33060 Nominal Tons Sensible 3.16 3.08 2.97 2.91 2.76 Sensible Heat Ratio (%) 0.80 0.82 0.84 0.87 0.90 HMS HL4S 77/61.2 40,1 Total Cooling Btu/H 46110 43820 41110 38830 37010 Sensible Cooling Btu/H 40050 38795 37815 37400 37010 Nominal Tons Sensible 3.34 3.23 3.15 3.12 3.08 Sensible Heat Ratio (%) 0.87 0.89 0.92 0.97 1.00 HA4S HL4S 77/59.6 35.1 Total Cooling Btu/H 44830. 43290 41280 39180 36995 Sensible Cooling Btu! 44830 43290 41280 39180 36995 Nominal Tons Sensible 3.74 3.61 3.44 3.27 3.08 Sensible Heat Ratio (%) 1.00 1.00 1.00 1.00 1.00 HMS HL4S 77/58.0 30.2 Total Cooling Btu/H 45245 43260 41265 39185 36980 Sensible Cooling Btu! 45245 43260 41265 39165 38980 Nominal Tons Sensible 3.77 3.81 3.44 3.26 3.08 Sensible Heat Ratio (%) 1.00 1.00 1.00 1.00 1.00 Model Number Indoor DB/WB % RH Part Load (Stage 1) Cooling Performance Data Outdoor Temperature 'F 75 85 95 105 115 HA4S HL4S 80/67.0 51.1 Total Cooling Btu/H 39000 38500 34000 31250 28500 Sensible Cooling Btu! 27100 26000 24900 23775 22650 Nominal Tons Sensible 2.26 2.17 2.08 1.98 1.89 Sensible Heat Ratio (%) 0.69 0.71 0.73 0.76 0.79 HMS HL4S 77/64.5 51.1 Total Cooling 8tu! 37095 34900 32520 30190 28240 Sensible Cooling Btu/H 30635 29950 28845 28600 28240 Nominal Tons Sensible 2.55 2.50 2.40 2.38 2.95 Sensible Heat Ratio (%) 0.83 0.86 0.89 0.95 1.00 HMS HL4S 77/62.8 45.4 Total Cooling Btu/H 35930 33740 32075 30170 28200 Sensible Cooling Btu/H 33050 32500 32075 30170 28200 Nominal Tons Sensible 2.75 2.71 2.87 2.51 2.35 Sensible Heat Ratio (%) 0.92 0.96 1.00 1.00 1.00 HA4S HL4S 77/61.2 40.1 Total Cooling Btu/H 35700 33900 32060 30160 28190 Sensible Cooling Btu! 35700 33900 32080 30160 28190 Nominal Tons Sensible 2.98 2.83 2.67 2.51 2.35 Sensible Heat Ratio (%) 1.00 1.00 1.00 1.00 1.00 HMS HL4S 77/59.6 35.1 Total Cooling Btu! 35685 33885 32045 30145 28180 Sensible Cooling Btu/H 35685 33885 32048 30145 28180 Nominal Tons Sensible 2.97 2.82 2.87 2.51 2.35 Sensible Heat Ratio (%) 1.00 1.00 1.00 1.00 1.00 HA4S HL4S 77/56.0 30.2 Total Cooling Btu! 35670 33875 32030 30135 28170 Sensible Cooling Btu! 35870 33875 32030 30135 28170 Nominal Tons Sensible 2.97 2.82 2.67 2.51 2.35 Sensible Heat Ratio (%) 1.00 1.00 1.00 1.00 1.00 Foram No. 53458-313 Supersedes 33458-712 Page 11of18 HA5S/HA5L Cooling Performance Data Indoor DB/WB Model Number Indoor DB/WB RH %Cooling Full Load (Stage 2) Performance Data Outdoor Temperatu a °F 75 85 95 105 115 HA5S HL5S 80/67.0 51.1 Total Cooling Btu/ 64850 60675 56500 53400 50300 Sensible Cooling Btu/H 44400 42600 40800 40150 39500 Nominal Tons Sensible 3.70 3.55 3.40 3.35 3.29 Sensible Heat Ratlo (%) 0.68 0.70 _ 0.72 0.75 0.79 HA5S HL5S 77/64.5 51.1 Total Cooling Btu/H 60245 57240 54000 50985 47510 Sensible Cooling Btu/H 42750 41780 40300 39300 37775 Nominal Tons Sensible 3.58 3.48 3.36 3.28 3.15 Sensible Heat Ratio (%) 0.71 0.73 0.75 0.77 0.80 HA5S HL5S 77/62.8 45.4 Total Cooling Blu/H 58130 55480 51995 48830 45605 Sensible Cooling Btu/H 45530 44665 42990 41685 40420 Nominal Tons Sensible 3.79 3.72 3.58 3.47 3.37 Sensible Heat Ratio (%) 0.78 0.81 0.83 0.85 0.89 HA5S HL5S 77/61.2 40.1 Total Cooling Btu/H 56325 53315 50390 47165 44080 Sensible Cooling Btu/H 48400 46870 45715 44270 42215 Nominal Tons Sensible 4.03 3.91 3.81 3.69 3.52 Sensible Heat Ratio (%) 0.86 0.88 0.91 0.94 0.96 HASS HL5S 77/59.6 35.1 Total Cooling Btu/H 54350 . ," 51690 50120 . 47600 45065 Sensible Cooling Btu/H 54350 ',' '. 51600 50120. 47600 45065 '. Nominal Tons Sensible 4.53 , 4.30 4.18 3.97 3.76 Sensible Heat Ratio (%) 1A0 • "- 1,00 , 1.00. 1.00 ' 1.00 HA5S HL5S 77158.0 30.2 Total Cooling Btu/H 54700 52425 ,. 50100 47610 45050 Sensible Cooling Btu/H 54700 ', ,'. -,52425 50100 , 47610 45050 Nominal Tons Sensible 4.56 " - 4.37 4.18 3.97 ' 3.75 Sensible Heat Ratio (%) 1.00 '1.00 " 1.00 . 1.00. 1A0 Model Number Indoor DB/WB �0 RH Part Load (Stage 1) Cooling Performance Data Outdoor Temperature °F 75 85 95 105 115 HA5S HL5S 80/67.0 51.1 Total Cooling Btu/H 48850 44425 40000 37550 35100 Sensible Cooling Btu/H 34350 33000 30700 29500 30100 Nominal Tons Sensible 2.86 2.75 2.56 2.46 2.51 Sensible Heat Ratio (%) 0.70 0.74 0.77 0.79 0.86 HASS HL5S 77/64.5 51.1 Total Cooling Btu/H 43075 40810 38125 35325 32780 Sensible Cooling Btu/H 31950 32200 29950 28575 29125 Nominal Tons Sensible 2.66 2.68 2.50 2.38 2.43 Sensible Heat Ratio (%) 0.74 0.79 0.79 0.81 0.89 HA5S HL5S 77/62.8 45.4 Total Cooling Btu/H 41660 39180 36730 34225 31450 Sensible Cooling Btu/ 34185 32380 31405 30505 29250 Nominal Tons Sensible 2.85 2.70 2.62 2.54 2.44 Sensible Heat Ratio (%) 0.82 0.83 0.86 0.89 0.93 HA5S HL5S 77/61.2 40.1 Total Cooling Btu/H 40360 37880 35500 33000 31450 Sensible Cooling Btu/ 35835 34265 33175 32725 31450 Nominal Tons Sensible 2.97 2.86 2.76 2.73 ' 2.82 ; Sensible Heat Ratio (%) 0.88 0.90 0.93 0.99 1.00 HA5S HL5S 77/59.6 35.1 Total Cooling Btu/H 39060 • 37400 .: 35480 33490 31390 Sensible Cooling Btu/H 39060 , ,. 37400 35480 " 33490. 31390 Nominal Tons Sensible 3.28 • 3.12', 2.96 ' ' 2.79 2.62 Sensible Heat Ratio (%) 1.00 1.00 ' 1.00 . 1.00 , 1.00 HASS HL5S 77/58-0 30.2 Total Cooling Btu/ 39240 " 37385 35460 33478 31415 Sensible Cooling Btu/H 39240" • ' 37385 35480 33475 - 31415 Nominal Tons Sensible 3.27.. . , 3.12., 7.95 2.79 _: 2:62 Sensible Heat Ratio (%) 1.00 , • 1.00 1.00. • 1.00;.. ,1.00 Forth No. S3458-313 Supersedes 53458-712 Page 12 of 18 Dimensions of Basic Unit forArchitecural & Installation Requirements (Nominal) MODEL WIDTH DEPTH - HEIGHT (W) rol (H) SUPPLY RETURN At C 8 E F G J K 1 M N 0 P 0 . R SI 82 T H42A H48A H60A 42.075 22.432 84.875 9.88 29.88 15.88 29.88 43.88 19.10 31.88 30.00 32.68 28.94 34.69 32.43 3.37 43.00 23.88 10.00 1.44 18.00 16.00 1.88 HA4S3 HA5S3 42.075 22.432 94.875 9.88 29.88 15.88 29.88 43.88 19.10 41.68 30.00 42.68 36.94 44.69 42.43 3.37 43.00 33.88 10.00 1.44 16.00 21.00 1.88 All dimensions are In inches. Dimensional drawings are not to scale H42 - 60A Right -Hand HA4 - 5S Models Bu0tIn Rain Hood 4' Pitch Heater Access Panel Electric Heat C. Breaker/ Disconnect Access Panel (Lockable) Economizer Alr Intake Hood Standard \. door vent door for . non -Econ. : models Front View CH 11' Low Voltage Electrical Entrance High Voltage Electrical Entrance Side View Drain Side Wall BMi raacketts rs (Built Top Rain Flashing SLoocation E Supply Air Opening Elleeca Entrances 1 Retum Air Opening S . T Bottom Installed Back View Bracket NOTE 1: Not used when ECONWMT Economizer Installed. Filter access Is through the ECONWMT hood. wsut0 Form No. S3458-313 Supersedes 53458-712 Page 13 of 18 Dimensions MODEL MOTH (W) of DEPTH (D) Basic HEIGHT,. M) Unit for. Architecural suv%.v, RETURN & Installation Requirements (Nominal) A' 8 C 8 E. • F 0 1 J K L. MNOP O R S1 62 T H42L H48L H60L 42.075 22.432 84.875 9.88 29.88 15.88 29.88 43.88 19.10 31.68 30.00 32.68 26.94 34.69 32.43 3.37 43.00 23.88 10.00 1.44 18.00 16.00 1.88 HL4S2 HL5S2 42.075 22.432 94.875 9.88 29.88 15.88 29.88 43.88 19.10 41.68 30.00 42.68 36.94 44.69 42.43 3.37 43.00 33.88 10.00 1.44 18.00 21.00 1.88 All dimensions are in Inches. Dimensional drawings are not to scale. Supply Air Opening Return Air Opening Side Wall Mounting Brackets (Built In) Top Hain Flashing Shipping Location Optional Electrical Entrances Drain Bottom/ Back View Installation Bracket Built In Hain Hood 4• Pitch Electric Heat Heater Access Panel C. Breaker) Disconnect Access Panel (Lockable) Standard flush vent door for non -Econ. models Economizer Air Intake Hood H42 - 60L Left -Hand HL4 - 5S Models Side View Front View NOTE 1: Not used when ECONWMT Economizer installed. Filter access is through the ECONWMT hood. Form No. 53458-313 Supersedes S3458-712 Page 14 of 16 Air Conditioning Wali -Mount Mode! Nomenclature 2 -Stage Compressor Models MODEL NUMBER HA— Right Hand HL — Left Hand CAPACITY 4S-4 Ton 5S - 5 Ton 3 REVISION HA -3 HL -2 K • ACCUMULATOR VOLTS & PHASE A - 230120818011 KW VENTILATION OPTIONS (See Table Below) FILTER OPTIONS P - 2 Inch Pleated (MERV 8) COLOR OPTIONS X - Beige (Standard) 1- White 4 - Buckeye Gray 5 - Desert Brown 8 - Dark Bronze A -Aluminum S - Stainless Steel Note: For OKW and circuit breakers (230/208 Volt), Insert 02 In the KW field of the model number. See Page 6 for available Factory Installed KW options and Page 7 for Field Installed Heater Packages. Ventilation Options' HA4 - 5S, HL4 - 55 Description Factory Installed Code No. Field Installed Part No. 1 J T CONTROL MODULES (See Chart Below) COIL OPTIONS X - Standard 1 - Phenolic Coated Evaporator 2 - Phenolic Coated Condenser 3 - Phenolic Coated Evaporator & Condenser OUTLET OPTIONS X - Front (Standard) Lead -Lag Controller Required Blank -Off Plate 8 BOP -5 MV4000-B 0) 0 Use MV4000-13C If Remote Communication capability Is required. Air Conditioning Control Modules STANDARD CONTROLS All Models HPC 1D LPC m CCM STD 1 STD 1 STD STD ALR 6? STD SK STD Factory Installed Code J Field Installed Part N/A STD = Standard equipment for these specified models. m HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note G. 0 LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is Included. See note m. CD CCM. Compressor control module has adjustable 30 -second to 5 -minute delay -on -break timer. On Initial power -up, or any time the power is interrupted, the delay -on -make will be 2 -minutes plus 10% of the delay -on -break setting. There Is no delay -on -make during routine operation of the unit. The module also provides the lockout feature (with 1 retry) for high andfor low-pressure controls, and a 2 -minute timed bypass for low-pressure control. 0 LAC. Low ambient control permits cooling operation down to 0'E 0 ALR. The alarm relay has a set of normally open and normally dosed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. 0 SK. Start kit standard on all -A single phase models. Form No. 53458.313 Supersedes S3458-712 Page 15 of 18 .Air'Condition ng Wall -Mount Model•Nomenclature 1 -Stage Compressor Models H SERIES CAPACITY 42-3%Ton 48 - 4 Ton 60 - 5 Ton VOLTS & PHASE A- 230/208/6011 VENTILATION OPTIONS (See Table Below) FILTER OPTIONS P - 2 inch Pleated (MERV 8) COLOR OPTIONS X - Beige (Standard) 1-Whtte 4 - Buckeye Gray 5 - Desert Brown 8 - Dark Bronze A -Aluminum S - Stainless Steel kD For OKW and circuit breakers (230/208 Volt), Insert OZ in the KW field of the model number. See Page 6 for available Factory Installed KW options and Page 7 for Field Installed Heater Packages. ® Economizers not available for Aluminum or Stainless Steel Units. T CONTROL MODULES (See Chart Below) COIL OPTIONS X - Standard 1 - Phenolic Coated Evaporator 2 - Phenolic Coated Condenser 3 - Phenolic Coated Evaporator & Condenser OUTLET OPTIONS X - Front (Standard) Ventilation Options -• H42 - 60A, HL.4 - 5S DescriptionFactory Installed Code No. Field Installed Part No. Lead -Lag Controller Required Blank -Off Plate B BOP -5 MV4000-B JADE -Series Full -Flow Economizer, Fully Modulating with Exhaust — Outdoor Dry Bulb Temperature Only T ECONWMT-T5B111 MV4000-B m JADE -Series Full -Flow Economizer, Fully Modulating with Exhaust — Outdoor Enthalpy Control yy ECONWMT-E58* MV4000-B D SPYDER-Series Full -Flow Economizer, Fully Modulating w/Exhaust — DC Load Controlled — Outdoor Dry Bulb Temperature Only F N/A MD4000-8 ID SPYDER-Series Full -Flow Economizer, Fully Modulating w/Exhaust — DC Load Controlled — Outdoor Enthalpy Control 0 G N/A MD4000-8 * Must specify color to match unit color: X = Beige, 4 = Buckeye Gray, etc. Economizers not available to match Aluminum or Stainless Steel Units. m Use MV4000-BC or M04000 -BC if Remote Communication capability Is required. CB4000 Communication Board can also be field installed In base MV4000-B or MD4000-B If not origlnalty equipped. m Requires DC load Input signal (0-10 VDC) from shelter Current Transformer measuring total DC amps — supplied by others. Air• Conditioning. Control Modules STANDARD CONTROLS All Models HPC 0LPC ® CCM ® LAC m ALR ® SK ® SK ® Factory Installed Code Field Installed Part STD STD STD STD STD J N/A STD STD STD STD STD • Field Installed Only CMC -15 STD STD STD STD STD • Field Installed Only SK111 STD = Standard equipment for these spedted models. m HPC. High pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note 0. ® LPC. Low pressure control is auto reset. Always used with compressor control module (CCM) which is included. See note m. m CCM. Compressor control module has adjustable 30 -second to 5 -minute delay -on -break timer. On initial power -up, or any time the power is Interrupted, the delay -on -make will be 2 -minutes plus 10% of the delay -on -break setting. There is no delay -on -make during routine operation of the unit. The module also provides the lockout feature (with 1 retry) for high and/or low-pressure controls, and a 2 -minute timed bypass for low-pressure control. ® LAC. Low ambient control permits cooling operation down to 0'F. C1 ALR. The alarm relay has a sot of normally open and normally dosed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. ® SK. PTCR start kit can be used with all -A single phase models. Increases starting torque 2.3x. Do not use If SK111 is used. ® SK. Start capacitor and potential relay start kit can be used with all -A single phase models. Increases starting torque 9x. Do not use if CMC -15 is used. CLIMATE CONTROL SOLUTIONS Page 16 of 16 Bard Manufacturing Company, Inc. Bryan, Ohio 43506 www.bardhvac.com Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read Important energy cost and efficiency Information available from your retailer. Form No. 53458 March, 2013 Supersedes: S3458-712 HERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-0224 DATE: 12/02/13 PROJECT NAME: SOUTHCENTER PLACE - VERIZON SHACK SITE ADDRESS: 16400 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: pt part, 0-10.6 /WV Building Division Fire Prevention 1111 Public Works Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12/05/13 Complete Incomplete Not Applicable Comments: Permit:CentertUse Only» '� • INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: Approved ❑ Notation: REVIEWER'S INITIALS: Approved with Conditions DUE DATE: 01/02/14 Not Approved (attach comments) ri DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: MACDONALD/MILLER FAC SO' C r 0 Washington State Department of Labor & Industries • Page 1 of 3 MACDONALD/MILLER FAC SOL INC Owner or tradesperson SIMONDS, DERRICK R Principals SIMONDS, DERRICK R WEBSTER, MARK E GOUGH, DAVID ANTHONY NOEL, STEPHANIE W SIGMUND, FREDRIC (End: 01/04/2011) LOVELY, STEVE C (End: 01/04/2011) HACK, RICHARD (End: 01/04/2011) KOPET, TYLER (End: 01/04/2011) TURLEY, DOUGLAS (End: 01/04/2011) TURLEY, DOUGLAS (End: 01/04/2011) Doing business as MACDONALD/MILLER FAC SOL INC WA UBI No. 602 254 260 PO BOX 47983 SEATTLE, WA98106 206-768-4180 KING County Business type Corporation Governing persons FREDRICJSIGMUND License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ....................................... Meets current requirements. License specialties GENERAL License no. MACDOFS980RU Effective — expiration 12/31/2002 — 01/03/2015 Bond LIBERTY MUTUAL INS CO Bond account no. 023006951 Received by L&I 12/31/2002 $12,000.00 Effective date 12/11/2002 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602254260&LIC=MACDOFS980RU&SAW= 03/10/2014 VZW Mall Rats 26, 2013 9:58:46 E z ro C ABBREVIATIO ABBV FULL NAME ABBV FULL NAME ABBV FULL NAME A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD-MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE-UP AIR NOMINAL OSA OBD OD RA REG REQ'D RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP TSTAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START/STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER UNIT NO. AC -1 AC -2 MFG & MODEL NO. NOM HEAT TONS KW STG FAN CFM ESP HP BARD H60A2-A05TPXXXJ 5 5 1 1775 0.25 1/3 OA CFM 2600 BARD H60A2-A05TPXXXJ 5 5 1 1775 0.25 1/3 2600 EER/ SEER 9.0/ 9.0/ IPLV ELECTRICAL VOLT/PH MCA 208/1 42 208/1 42 WT LBS 525 525 NOTES REPLACE, 1-6 REPLACE, 1-7 NOTES: 1. PROVIDE WITH AIRSIDE ECONOMIZER. 2. UNIT TEST IN ACCORDANCE WITH AHRI 390 AND IS INCOMPLIANCE WITH SEC TABLE 14-1D SPVAC. 3. UNIT TO PROVIDE COOLING FOR TELE COMM ROOM. 4. PROVIDE WITH 24/7 T -STAT 5. INSTALL UNIT PER STRUCTURAL CALCULATIONS 6. UNIT PROVIDED BY VERIZON 7. UNIT INSTALLED FOR REDUNDANCY SEPARATE PERMIT REQUIRED FOR ■ Mebbaniod Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION VICINITY MAP NO SCALE . THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2012 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2012 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2012 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0.75 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2012 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.5 OF THE 2012 IBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 717.6.2.1 OF THE 2012 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND 'THE REQUIREMENTS OF THE CODE. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 13 2013 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. City of da BUILDING ISION 10. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18". 11. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 12. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 13. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 14. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 15. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER APN#: 2623049021 SITE ADDRESS: 16400 SOUTHCENTER PKWY TUKWILA, WA 98188 LEGAL DESCRIPTION: PARCEL 1 OF CITY OF TUKWILA REVISED SHORT PLAT #77-51-55 AKA BLA #3-79 REC #7904180861 SD PLAT DAF - POR SE 1/4 OF NW 1/4 BEG AT MONUMENTAL INTSN OF C/L'S OF SOUTHCENTER PARKWAY 57TH AVE S & STRANDER BLVD 8 164TH ST TH S 8-45-5 E 325.05 FT TH S 0-25-58 E 30 FT TO AN INTSN WITH S MGN SD STRANDER BLVD & TPOB TH CONTG S 0-25-58 E 200 FT TH S 89-45-58 E 350 FT TH 0-25-58 E 1093.20 FT TH N 89-43-19 W 626.31 FT TO E MGN SOUTHCENTER PARKWAY TH N 0-57-48 W 1241.85 FT TO A PT OF CURVE TH NLY & ELY ALG ARC OF CURVE TO RGT RAD 50 FT THRU C/A 91-11-50 79.53 FT TO S MGN STRANDER BLVD TH S 89-45-58 E 237.72 FT TO TPOB LESS POR OF SD PAR 1 FOR ST UNDER REC NO 8310250922 LESS RD PER SUP COURT #09-2-19459-9 KNT PROJECT ENGINEER ACCOUNT MANAGER SHEET METAL FOREMAN NAME TYLER VANDOOREN BRAD OLAND CHRIS HOLLINGSWORTH COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206-768-3890 206-768-3910 206-407-2620 EMAIL TYLER.VANDOOREN@MACMILLER.COM BRAD.OLAND@MACMILLER.COM CHRIS. HOLLINGSWORTH@MACM ILLER.COM NAME TITLE NAME TITLE TM0.01 TM2.01 TM3.01 SCHEDULES - HVAC ROOF PLAN - HVAC ELEVATIONS Wirt% REPLACE (2) EXISTING 4 -TON WALL MOUNT AC UNITS 1 _ (2) NEW 5 -TON PACKAGED WALL MOUNT AC UNITS. INSTALL WITH LEAD/LAG CONTROLLER. f✓ 5 u_.--- 61 ac, , S /7/1146}4 i � 0 /, 'ons vc CLOV-e-o_ / Cir /C5 �ov, CSC d� REVISIDNS No changes shall be made to the ... of work without prior appoval of Tukwila Building Div KOT1 FTvisions will require a newplan r ni may include additional plan r _ FILE COPY it No. 0 Man review ;` + 1► ► tO CMSand pprovat of construction documents does not autfr i the violation of any or ordinance. Receipt of ap '�''f H is ed' city Of'hticwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 2 2013 PERMIT CENTER MIS-o'�2� O 0 V CO 0 i- 0 LIL� o co • n - CO COrn NI - a) a)o - N E 0 ci) ti �• o @ z E • rn d cy) '7 0 0 N N ai ✓ 0 ti co C7 0 0) LL 0 2 Z .0 J tip REVISIONS: 1 1 1 vJ (/) VJ dW DC J -I W J zz o aQ N_ N_ Q Et O J WWY ENGINEER: REVISIONS: LAST REVISED: SSUED FOR CONSTRUCTION F- 0 z T VANDOOREN 11-07-13 CHECKED BY: B GEZON DATE PLOTTED: CAD: ISSUE DATE: D LAMBERT DRAWING NUMBER: C-2063-7336820-00 SHEET NUMBER: TM0.01 J:\733\6820 VZW Mall Rats M 2 0 M N E z ti 0 cn STHA\DHD BLVD REVIEWED FOR CODE COMPLIANCE APPROVED DEC 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 0 2 2013 PERMIT CENTER O co coO N a) c 0 .c CL 4.11110101, EXPIRES 7/6/1 REVISIONS: C�� r (1)w -� w z zz07 ,07 N_ N_ ceOC°J wuri)) li »72.p cL w H ENGINEER: T VANDOOREN CHECKED BY: B GEZON CAD: D LAMBERT DRAWING NUMBER: C-2063-7336820-00 REVISIONS: z 0 U cn z 0 0 0 LL 0 w U) (1)0 z LAST REVISED: 11-07-13 DATE PLOTTED: ISSUE DATE: SHEET NUMBER: TM0.01 S REVIEWED FOR CODE COMPLIANCE APPROVED DEC 13 2013 City of Tukwila BUILDING DIVISION ° 1214 RECEIVED CITY OF TUKWILA DEC 022013 PERMIT CENTER z 1 /2" = 1'-0" G� 0 0 (1) 17.1 LL 0 co 0) LL 0 0 2 z U_ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 W J w Q—� zz 00= NN! Eno WW8 E ENGINEER: W a REVISIONS: REVISIONS: LAST REVISED: Z 0 U CC (1)Z 0 0 0 LL 0 W 0 Z T VANDOOREN 11-07-13 CHECKED BY: B GEZON DATE PLOTTED: CAD: ISSUE DATE: D LAMBERT DRAWING NUMBER: 0-2063-7336820-00 SHEET NUMBER: TM2.01 08. 2013 8:32:32 E AC -1 24'-0" L_ OSOUTH WEST ELEVATION N.T.S. RE E D FOR CODE COMPLIANCE APPROVED DEC 13 2613 City of Tukwila 1 BUILDING DIVISION 12'-0" ON0RTH WEST ELEVATION N.T.S. 13- O27J1 RECEIVED CITY OF TUKWILA DEC 0 2 2013 PERMIT CENTER o L' � 45 co( 0 (Li o2-0 o) N E 1 a`) i 0 LL �� 0 cu 0 O p S " q 2 f • Q M $ Z Q Nr V V 1 N J C� 0 a; G ti0_ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Cn U) W J J J�� d 2 W zzW O 0= NN's • cCo w w » 7 ENGINEER: W Q 0 REVISIONS: w 0 REVISIONS: LAST REVISED: z 0 U F-- (/) z 0 U 0 u_ 0 W VJ 0 z T VANDOOREN 11-07-13 CHECKED BY: B GEZON DATE PLOTTED: CAD: ISSUE DATE: D LAMBERT DRAWING NUMBER: 0-2063-7336820-00 SHEET NUMBER: TM3.01 ID D AC -1 AC -2 I o 00 \ \ / �-� / ON0RTH WEST ELEVATION N.T.S. 13- O27J1 RECEIVED CITY OF TUKWILA DEC 0 2 2013 PERMIT CENTER o L' � 45 co( 0 (Li o2-0 o) N E 1 a`) i 0 LL �� 0 cu 0 O p S " q 2 f • Q M $ Z Q Nr V V 1 N J C� 0 a; G ti0_ 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Cn U) W J J J�� d 2 W zzW O 0= NN's • cCo w w » 7 ENGINEER: W Q 0 REVISIONS: w 0 REVISIONS: LAST REVISED: z 0 U F-- (/) z 0 U 0 u_ 0 W VJ 0 z T VANDOOREN 11-07-13 CHECKED BY: B GEZON DATE PLOTTED: CAD: ISSUE DATE: D LAMBERT DRAWING NUMBER: 0-2063-7336820-00 SHEET NUMBER: TM3.01