Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-0226 - SIMON & GOLUB - ALTERATION
This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M13-0226 Simon & Golub – Building 9 13035 Gateway Dr S DIGITAL RECORDS (DR) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Code Exemption Brief Explanatory Description Statute/Rule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals’ social security Personal Information – numbers are redacted to protect those Social Security Numbers 5 U.S.C. sec. individuals’ privacy pursuant to 5 U.S.C. sec. DR1 Generally – 5 U.S.C. sec. 552(a); RCW 552(a), and are also exempt from disclosure under section 42.56.070(1) of the Washington 552(a); RCW 42.56.070(1) State Public Records Act, which exempts under 42.56.070(1) the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information – expiration dates, or bank or other financial RCW 21 DR2 Financial Information – account numbers, which are exempt from 42.56.230(5) disclosure pursuant to RCW 42.56.230(5) RCW 42.56.230(4 5) , except when disclosure is expressly required by or governed by other law. SIMON & GOLUB 13035 GATEWAY DR M13-0226 • City of Tukwila • Department of Community Development / 2 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov Parcel No: Address: Project Name: MECHANICAL PERMIT 0004800015 Permit Number: M13-0226 13035 GATEWAY DR S BLDG 9 Issue Date: 12/23/2013 Permit Expires On: 6/21/2014 SIMON & GOLUB Owner: Name: Address: EPROPERTY TAX INC DEPT #207 PO BOX 4900 , SCOTTSDALE, WA, 85261 Contact Person: Name: CHRIS WALKER Address: 899 W MAIN ST, AUBURN, WA, 98001 Contractor: Name: IECS INC. Address: P.O. BOX 19252 , SEATTLE, WA, 98109 License No: IECS***044QL Lender: Name: Address: /11 Phone: (253) 939-9495 Phone: (206) 939-9495 Expiration Date: 11/20/2014 DESCRIPTION OF WORK: INSTALL EXHAUST FAN AND DUCTING FROM JEWELERS WORK STATION TO ROOFTOP VENT AND RECONFIGURE DUCTWORK AND GRDS TO ACCOMMODATE NEW SPACE CONFIGURATION. Valuation of Work: $0.00 Type of Work: Fuel type: Fees Collected: $286.69 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: /4727,)3//_3 • .. I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit a agree to the conditigns attached to this permit. Signature: Print Name: is a, (1G (/ - Date: /Z- 2 3-/ 3 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: Readily accessible access to roof mounted equipment is required. 4: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 5: Every occupied space other than enclosed parking garages and buildings used for repair of automobiles shall be ventilated in accordance with the applicable provisions of the International Mechanical Code. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***MECHANICAL PERMIT CONDITIONS*** PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http J/www. Tukwi]aW A. gov Mechanical Permit No. Project No. 1�- o'LZIo Date Application Accepted: Date Application Expires: otok99 I''r (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans rmist be complete in order to be accepted fir plan review. Applications will not be accepted through the manor by floc. **please print** SITE LOCATION 2 ( C (�' c 1 ( « King Co Assessor's Tax No. f) ()(') L tS 0 - 0015 Site Address: 1 3 / •(rw� OR Bq Suite Number: Floor: Tenant Name: 51 in 04(1 30 ,) New Tenant: ❑ Yes cg „No PROPERTY OWNER n,�,,V Name: Ck ri S u3 cd Name. C(Zke_.. City ,Y) lJ�A a 1 l Address: a10 9 t 5 1)1\61I NAS ' D k 011 t City: � it lel " qUA CONTACT PERSON - person receiving all project comnnmication n,�,,V Name: Ck ri S u3 cd Address: g ' a 1 9 q I (i? cij 54_, v� �S City ,Y) lJ�A a 1 Ph fia55.� -- q a$. g' q ax 53- 9 ., / C Email: IC.h Nt S W A S-e.4.4i1Za1P,C la rULCL cvwi MECHANICAL CONTRACTOR�jINFORMATION Company Name PCL+ iine ella h ((' Address:1, 0lin, j_ Q77 Wt I,/ 6 V j r City: bi Zip9$0D1 Phon ; -9351—M5 Fax:a- 3 -937- 9g-6 co ContrRe No.: Exp Date: F.c twit/I-9.0 -iit Tukwila Business License No.: u S - 0994_9 6 Vahiation ofproject (cortractor's bid price): $ 3 100 0 b O '' nn.�'' ,, nn-- _�` Describe the scope of work in detail: ST a l ( EX h a At, rCu1, ' 0.f1 ODU t J �Ydw' a.0.e�.eA4) W0C-\ o }o re kba..Y* o t r.e_edy)R.Tethiz, WJ C ourtat CGRO s QC_ COM n -N ae ne.w Sp&ce_ C' Ai9ur th°oyj Use: Residential: New ❑ Replacement 0 Commercial: New ❑ Replacement 0 Fuel Type: Electric ❑ Gas 12 Other: WApplcationnFoma-AppraatbmonLi \2011Appiiat>onectunsalPeraitApplicatimRevised8.9.11.doca Read- Angust 2011 Page 1 oft Indicate type ofinechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Fbor frnace Suspended/walVfbor mounted heater Appliance vent Repair or addition to hcathefrig'cooling system Air handling unit <10,000 cfin Unit Type Qty Air handlingunit >10,000 cfin Evaporator cooler Ventilation fan connected to singk duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/iodustrial Unit Type QtY Fre damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in aIlcases, a value ofconsttuction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review— applications for which no permit is issued within 180 days following the date ofapplication shall expire by limitation. The building offcialmey grant one extension oftime for additionalperiods not to exceed 90 days each. The extension shallbe requested in writing and justifiabk cause demonstrated. Section 1053.2 IntemationalBuilding Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON. AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR RI t1� Signature: + 1 /� Print Name: C.h r\ S W 0.i €.0 v(/ Mailing Address: D 9q H:LAppticatioffi'Sro m-Applicatvm OnLin`2011 Applin tioraWlechani:alPernit ApplicatvnRevised 8-9-11 dont a.e.a)nti Date: / -3 13 -7 Day Telephone: r ©( ` c 5 - 035 / 1.,t, 1/O .k ` g001 City State Zip PAn,. 7 nf Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $229.35 M13-0226 Address: 13035 GATEWAY DR S BLDG 9 Apn: 0004800015 $229.35 MECHANICAL $229.35 PERMIT FEE PERMIT ISSUANCE BASE FEE TOTAL FEES PAID BY RECEIPT: R477 R000.322.100.00.00 R000.322.100.00.00 $196.85 $32.50 $229.35 Date Paid: Monday, December 23, 2013 Paid By: IECS INC Pay Method: CHECK 55876 Printed: Monday, December 23, 2013 9:01 AM 1 of 1 CRWYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT ( QUANTITY PAID $57.34 M13-0226 Address: 13035 GATEWAY- DR S BLDG 9 Apn: 0004800015 $57.34 MECHANICAL PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R242 R000.322.102.00.00 $57.34 $57.34 $57.34 Date Paid: Tuesday, December 03, 2013 Paid By: IECS, INC Pay Method: CHECK 55750 Printed: Tuesday, December 03, 2013 3:26 PM 1 of 1 I?WSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 3-622 , Project: !olu Type of Inspection: Address: t3n3i COAT- cA. , Jb Date Called: Special Instructions: Date W ante :Q iJ il - 0P . Requester • `__, Phone No: 'Approved per applicable codes. DCorrections required prior to approval. COMMENTS:] C1\,t-cAV- - A M,-bv,13)eir ,-41 1 spe Date: I—e to next ins -PECTION FEE REQUI ED. ection fee must be p at 6300 Southcenter Bl d., Suite 100. Call=to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 �V 1 m1aozz6 Project: S I PION 4604 6 Type of Inspection: r-, rJ'iL Address: 13035 ( aJ /D2 Date Called: Special Instructions: Date Wanted: r f '--3 ! L.1 a.m. p.m. Requester: Phone No: (1--5 ElApproved per applicable codes. El Corrections required prior to approval. COMMENTS: R e Aci g sto p i ti ;ruffc� I Lie I/,Ir(;JJ hisT r&J P • Re-17,i-viki cLA Date_ n R`EUSPECTION FEE RE UIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Mt 3-0226, Project:,,,..Type ,AVCrN; of Inspection: �Rcitc(k-,lam Address: 1 5035 GA"r uA Date Called: Special Instructions: f \ . Date Wanted: —L_ I Li' p.m. Requester: Phone No: Approved per applicable codes. ' Corrections required prior to approval. COMMENTS: J0 629pry ,Z4/.:t/ = rJ Rol Inspect d : Date: --z—,y SPECTION FEE RIUIRED. Prior to next inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. FILE COPY Pamlt No...413"" P�1 r Mew appresal is su jecttoeras £Zrual of oon$lrus ion documents does m Nation of ary adopted cods a .11 appy Heid r; and By OAK REMOVE ONE DOOR MAKE OTHER EXIT ONLY graZITZTO MAT ■ ■ ■ ■ LARGE CODE. FMB ■ ■ ■ CARD KEY ACCESS CONTROLS SECURED WAR SEQ1FiED RECEPT 3 I I I I I I� I I _—1T1GTl13ES— L ILK BENCH I CLOSET SALES CUBES SEPARATE PERMIT REQUIRED FOR: 0 �ed�aNrat CSG of Tukwila `I= t i.`"-" 3G DIVISION P r OFFICE IM ■ .■■■■Nig ■ NEW 5TOR 111 ■ OFFICE OFFICE ■ ■ ■ 0 1— L ■ EXIT PATH ▪ MULTI lik/B618116IIIIIII•••191- 9111111••••••MVSIMI iNpouim: r J ■ ■ ■ ■ ■ ■ ■ r L J L VERIFY MI ER AND DATA DROPS VIA PQIER OLE WITH IMRE CONTRACTOR r T ~ a r No Changes shall be of work without pr ukwila Buildin will regtiiri an J may include addition REVIEWED FOR CODE COMPLIANCE APPROVED DEC 19 2013 City of T kwilaWet BUILDING DIVISION • • r.. L renew fee OFFICE OFFICE 1 L J I I I 1 I I I I J -T I■ L r STORAGE CQttNICATION MDR 0 0 IT OFFICE 1 It 16 EXIT PATH 5RYaLE EXIT MAKE EXIT ONLY GATEWAY CORPORATE CENTER: BLDG 9 TENANT: SIMON AND GOLUB • INTERURBAN AVE SO. & S0. 133RD TUKWILA, WASHINGTON °' `C NI 1 TRAINING IPX245' 21 CODE.00C v r� • 2 VENOM is II P41mARBArE I DISI 'I 2 LASER w 1 1,71 L J - 1 T 1 IV'TI 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 0 1 J L.L J SECURED RECEIVING 9'X11' 3 SHIPPING OASES G IELM STCIt SECOND FLOOR EXIT STAIR LT 1 SUM STORAGE a• ERAL0Flo •v PHOTO • n• o• MERCHANDI COD:ERENCE b■■■■B 1. 1 h STORAGE 1 WORK I5 4I( - II 91 COW. a N3 EQUIP RM • nn: • EXIT PATH SINGLE EXIT WANSICUSE CO/11:64 ELECT AND SPRINKLER SS 5F. NORTH J SEOJRE RECEIVING 401 01 NE - w Fr -x.41 o ✓t Ro o f. b -t f O -Te d✓e-"` 5 fable R&/cxciLe_ &riIk5 fo r, - Nev X11 a/ -cot e-W4o ve 7Z) ,,, s IV) / /Q1 -()v,4 6eaf Rep /ace__ CA, ,*'GI cOri e5 1,`,1crn • RECEIVED CITY OF TUKWILA DEC 0 3 2013 PERMIT CENTER AIR QUALITY AND ENERGY CODE These plans comply with the 2012 IMC including Washington State Amendments Sec 403 Mechanical Ventilation and the 2012 Washington State Energy Code. 1 ST FLOOR :EQUIPMENT AND POWER PLAN SCALE: 1/8'=1'-0" 0' 1' 4' 8' 16' 24' 32' 40' SCALE 1/8" = 1'-0" 09-26-13 REV 10-01-13 VA:922 T-5 /JGREENHECK FILE COPY Building Value irtil ____It No. Printed Date: 12/3/2013 Job: Seattle Mech Simon Golub Jewlers Mark: Mark 1 Model: G -095-D Direct Drive Centrifugal Roof Exhaust Fan Dimensional Quantity 1 Weight w/o Acc's (Ib) 20 Weight w/ Acc's (Ib) 40 Optional Damper (in.) 10 x 10 Roof Opening (in.) 12.5 x 12.5 Performance Requested Volume (CFM) 500 Actual Volume (CFM) 500 Extemal SP (in. wg) 0.125 Total SP (in. wg) 0.125 Fan RPM 976 Operating Power (hp) 0.03 Elevation (ft) 433 Airstream Temp.(F) 70 Air Density (ft3) 0.074 Tip Speed (ft/min) 2,778 Static Eff. (%) 35 Motor Motor Mounted Yes Size (hp) 1/8 V/C/P 115/60/1 Enclosure ODP Motor RPM 1550 Windings 1 NEC FLA* (Amps) NA Sound Power by Octave Band 0.35 0.30 0.25 rn 0.20 P. 0.15 ti 1 0.10 0.05 0.00 L. 0 .11 • • 17 Reference assembly view drawings for actual dimensions with mounted accessories 'Overall height may be greater depending on motor r 14 63 1EVIEWED FOR !CODE COMPLIANCE 1.75 APPROVED DEC 192013 0.14 City of Tukwila EIILDING.OIVISION 0 1 2 3 4 Volume (CFM) x 100 Operating Bhp point Operating point at Total SP Operating point at External SP Fan curve - System curve Brake horsepower curve Sound Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones Inlet 69 64 57 50 46 46 38 32 55 43 3.6 CAPS 4.13.1198 5 6 7 0.10 0.08 s 3 0.06 a Y ca 0.04 m` 0.02 0.00 RECEIVED CITY OF TUKWILA DEC 0 3 2013 PERMIT CENTER Notes: All dimensions shown are in units of in.. 'FLA - based on tables 150 or 148 of National Electrical Code 2002. Actual motor FLA may vary, for sizing thermal overload, consult factory. LwA - A weighted sound power level, based on ANSI S1.4 dBA - A weighted sound pressure level, based on 11.5 dB attenuation per Octave band at 5.0 ft - dBA levels are not licensed by AMCA Intemational Sones - calculated using AMCA 301 at 5.0 ft Z:\Chad\winjobs\Seattle Mech Simon Golub Jewlers.gfcj kAl2 amca ammo RRTlnGS sounD nwene IRi MoocInnnn Page 1 of 9 LGREENHECK Building Value in Air. Printed Date: 12/3/2013 Job: Seattle Mech Simon Golub Jewlers Mark: Mark 1 Model: G -095-D Direct Drive Centrifugal Roof Exhaust Fan Standard Construction Features: - Aluminum housing - Backward inclined wheel - Aluminum curb cap with prepunched mounting holes - Birdscreen - Ball bearing motors (sizes 100-180), sleeve bearing motors (sizes 60-95) - Motor isolated on shock mounts - Corrosion resistant fasteners. Options & Accessories: UL/cUL 705 Listed - "Power Ventilators" Switch, NEMA -1, Toggle, Junction Box Mounted & Wired Roof Curb-Galv., GPI -17-G12, Under Sized 1.5 in. Total Damper, WD -100 -PB -10X10, Gravity Operated (Loose), Not Coated Solid State Speed Control, 5 Amp (PN 385031) Shipped Loose Unit Warranty: 1 Yr (Standard) CAPS 4.13.1198 Z:\Chad\winjobs\Seattle Mech Simon Golub Jewlers.gfcj Page 2 of 9 fGREENHECK Building Value in Air. Printed Date: 12/3/2013 Job: Seattle Mech Simon Golub Jewlers Mark: Mark 1 Disconnect Switch Enclosure Rating: NEMA -1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: Manufacturer: Pass and Seymour Cycle: Overload Protection: None Phase: Mounting: Mounted and Wired RPM: 1/8 hp 60 1 1550 Voltage: 115 Amperage: 15 Switch Pole(s): 1 Wiring (Exp. Resist.): None Electrical Drawing Details 00.28 (4 HOLES) 4.35 1.06 1.65 0.72 CAPS 4.13.1198 1.06 2.50 Wiring Schematic UL Listed: Yes CSA Approved: Yes Rating: 1/2 hp Notes: All dimensions shown are in units of in. Z:\Chad\winjobs\Seattle Mech Simon Golub Jewlers.gfcj Page 3 of 9 LSGREENHECK Building Value in Air. Printed Date: 12/3/2013 Job: Seattle Mech Simon Golub Jewlers Mark: Mark 1 Assembly Drawing Type: Direct Drive Centrifugal Roof Exhaust Fan Exhaust Damper & Ductwork Suggested Roof Opening 10.0 12.5 SQ SQ TOP VIEW X21.8 Dia. -- 1 L J f--17.01 Flat Roof Curb —7 t 14.6 4 0 26.6 1 1.8-' 12.0 FRONT VIEW Notes: All dimensions shown are in units of in.. CAPS 4.13.1198 Z:\Chad\winjobs\Seattle Mech Simon Golub Jewlers.gfcj Page 4 of 9 0GREENHECK Building Value in Air. Printed Date: 12/3/2013 Job: Seattle Mech Simon Golub Jewlers Mark: Mark 1 Horizontal Mount Exhaust Damper Model: WD -100 Standard Construction Features: - Model WD -100 is a horizontal mount exhaust damper (air flow up) and is constructed of 18 ga galvanized steel with pre - punched mounting holes - Damper blades are 0.025 in. roll formed aluminum with vinyl seals on the closing edge, and spring assisted for ease of opening - Steel axles are 0.188 in. diameter zinc plated mounted in acetal bushings - Synthetic axle bearings CAPS 4.13.1198 10_ DAMPER 10 L25 TYP. SECTION VIEW Notes: All dimensions shown are in units of in. Width And height furnished approximately 0.125 in. undersize Z:\Chad\winjobs\Seattle Mech Simon Golub Jewlers.gfcj Page 5 of 9 fGREENHECK Building Value in Air. Printed Date: 12/3/2013 Job: Seattle Mech Simon Golub Jewlers Mark: Mark 1 Roof Curb Model: GPI Material: Galvanized Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure - Constructed of either 18 ga galvanized steel or 0.064 in. aluminum - Straight Sided without a cant - 2 in. mounting flange - 1 in. thick 3 Ib density insulation - Height - Available from 8 in. to 42 in. as specified in 0.5 in. increments. Notes: - The Maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in.. - The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. - The Roof Opening Dimension may NOT be the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 10 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. To prevent corrosion, they are coated with Greenheck's high performance Permatector coating. 15.5 15.5 ISOMETRIC VIEW Notes: All dimensions shown are in units of in. CAPS 4.13.1198 Z:\Chad\winjobs\Seattle Mech Simon Golub Jewlers.gfcj Page 6 of 9 jGREENHECK Building Value in Air. Printed Date: 12/3/2013 Job: Seattle Mech Simon Golub Jewlers Mark: Mark 1 0.8 0.7 0.6 3 0.5 0.4 0a. .3 0 � 0.2 0.1 0.0 G -095-D Performance Min/Max Fan Curve Requested Volume (CFM) Actual Volume (CFM) External SP (in. wg) Total SP (in. wg) Fan RPM Operating Power (hp) 500 500 0.125 0.125 976 0.03 0.10 0.08 3 0 0_ 0.06 Y co W 0 Volume (CFM) x 100 A Operating Bhp point Operating point at Total SP • Operating point at External SP Fan curve -- - - Systemcurve Brake horsepower curve CAPS 4.13.1198 Z:\Chad\winjobs\Seattle Mech Simon Golub Jewlers.gfcj Page 7 of 9 ;HERMIT COORD COPY 114i PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-0226 DATE: 12/03/13 PROJECT NAME: SIMON & GOLUB SITE ADDRESS: 13035 GATEWAY DR, BLDG 9 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPART �M,MENTS:piitir tat. Building Division Public Works Nle ��ocii Fire Prevention Structural u Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 12/05/13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 01/02/14 Approved ❑ Approved with Conditions g Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: IECS INC Washington State Department of Labor & Industries • Page 1 of 3 IECS INC Owner or tradesperson HUMPHREY, GEORGE Principals HUMPHREY, GEORGE Doing business as IECS INC WA UBI No. 601 639 846 PO Box 19252 SEATTLE, WA98109-1252 206-939-9495 KING, County Business type Corporation Governing persons GEORGEHUMPHREY License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. IECS***044QL Effective — expiration 11/13/1996 — 11/20/2014 Bond No bonds during the previous 6 year period. Insurance Nationwide Mutual Ins Co Policy no. ACPACTO7515636456 Received by L&I 07/26/2013 Savings (in lieu of bond) Received by L&I 11/20/2001 Savings account ID $1,000,000.00 Effective date 08/01/2013 Expiration date 08/01/2014 $6,000.00 Effective date 11/20/2001 httns://secure.lni.wa.>?ov/verify/Detail.aspx?UBI=601639846&LIC=IECS * * *044QL&SA... 12/23/2013