Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-0227 - BUFFALO WILD WINGS - ALTERATION
BUFFALO WILD WINGS 295 TUKWILA PKWY M13-0227 Parcel No: Address: City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 9202470100 Permit Number: 295 TUKWILA PKWY Issue Date: Permit Expires On: Project Name: BUFFALO WILD WINGS M13-0227 12/30/2013 6/28/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: WESTFIELD PROPERTY TAX DEPT PO BOX 130940 , CARLSBAD, WA, 92013 GILBERT SALINAS 1411 R ST NW , AUBURN, WA, 98001 AMBIENT CONTROL CO INC 1020 5 344 ST, SUITE 203 , FEDERAL WAY, WA, 98003 AMBIECC101PW 1// Phone: (253) 876-9933 Phone: (253) 661-5844 Expiration Date: 10/25/2015 DESCRIPTION OF WORK: RUN REFRIGERATION LINES TO WALK-IN COOLER EQUIPMENT PROVIDED BY CUSTOMER Valuation of Work: $6,250.00 Type of Work: NEW Fuel type: ELECT Fees Collected: $219.30 Electrical Service Provided by: Water District: Sewer Distric: Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: I Date: I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and a: to the condi ' s attached to this permit. Signature: ��� / i Date: Print Name: /WA/ /'/Zs /2/3d»3 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 2: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 3: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 4: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 7: ***MECHANICAL PERMIT CONDITIONS*** 8: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 9: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUKW Community Developm epartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MechanicalPSit No. _ _ O Project No. Date Application Accepted: , Date Application Expires: ( (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: Tenant Name: 8 /h ld [.f a✓'s, S PROPERTY OWNER Name:Ago/ (4,./6eri gg'15 Name: Address: /q(/ ,( 7 4 4. Contr Reg No.: Exp Date: ,M 81 ecr /oaP� /01251 zs — Address: City: igUkr/ State: ox City: State: Zip: CONTACT PERSON - person receiving all project coninunication. Name:Ago/ (4,./6eri gg'15 City: At / !7Ur/t/ State: LUlf ZiP:q y Address: /q(/ ,( 7 4 4. Contr Reg No.: Exp Date: ,M 81 ecr /oaP� /01251 zs — Tukwila Business License No.: ?I q 78--S'-' b City: igUkr/ State: ox Zip: cr,,��„/ ��`` Phone: , -876---?f3.3 Fax: Email: King Co Assessor's Tax No.: Suite Number: Floor: New Tenant: ❑ Yes ❑.. No MECHANICAL CONTRACTOR INFORMATION Company Name: m 6 few/ (bbet/ 40 / Address: Ai& R s, tiw City: At / !7Ur/t/ State: LUlf ZiP:q y Phone: 253-876—y_,?j Fax: 2f3 —i76—rP23 Contr Reg No.: Exp Date: ,M 81 ecr /oaP� /01251 zs — Tukwila Business License No.: ?I q 78--S'-' b Valuation of project (contractor's bid price): $ (4A ” Describe the scope of work in detail: RPLIr" 79-e4 6,47 //e i %e/ (10 o/c v' f 7 liij0 fu o r,T , 1% vi al .6y (� S)(s•i�rdv, Use: Fuel Type: Residential: New Commercial: New Electric Replacement Replacement Gas ❑ Other: DAct-3d H:Wppltcattons\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 l.docx Revised: August 2011 Page 1 of 2 bh Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Fumace <100k btu Fumace >1001: btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm • Unit Type Qty` Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type. Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment9 , Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES = Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER , j ORI Signature: Print Name: Mailing Address: /g/ ,94/ �74 /q,/ Rs/ , cv H:Wpplications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Day Telephone: Date: /2/6; 206 --SM—31/d'— X6/6 5I-0 o/ City State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT ( QUANTITY PAID $219.30 M13-0227 Address: 225 TUKWILA PKWY 1 Apn: 9202470100 $219.30 MECHANICAL $219.30 PERMIT FEE PERMIT ISSUANCE BASE FEE TOTAL FEES PAID BY RECEIPT: R257 R000.322.100.00.00 R000.322.100.00.00 $186.80 $32.50 $219.30 Date Paid: Thursday, December 05, 2013 Paid By: AMBIENT CONTROL Pay Method: CREDIT CARD 07704G Printed: Thursday, December 05, 2013 8:35 AM 1 of 1 CRWSYSTEMS INSPECTION RECORD_ Retain a copy with permit , INSPECTION NO. PERMIT NO. CITY OF TUKWILA•BUILDING DIVISION 6 6300 Southcenter Blvd., #100, Tukwila. WA.98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 -A1. 13 -0"0-7 Pr ject: �L u fr L -t7 tkii (A •. ,A J Type of Inspe tion: Nl2.c _ � iv't-L..a- Adelrei - _ `' n (/ t Date Called: �` Special. Instructions: ' 1Date ' Wanted: j - � t _'Z_ �� a.m. �.m� Requester: r- Phone No: • Approved per applicable codes. _ . LJ Corrections required prior to approval. COMMENTS poTk(A pt s'. }t_7 Date: n REINSPECTION FEE R‘6. - Prior to nextinspection, fee must be - paid at 6300 Southcenter Blvd.: Suite 100. Calt to schedule. reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO.PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 mo -o2.27 (206) 431-3670 Pro ¶ o !!xt A vj �n A TyKoo l)(o (n: -" id Me Address: _ , /� U�Q%ielU�LtI D: --� 6 c --mss fee ", , �� Special Instructions: ,9. t Date Wanted: 1— - 11 ��`,�a pT,. p.m. Requester: Phone t19: 3 — o� � 99,33 Approved per applicable codes. Corrections required prior to approval. COMMENTS: k Inspe tor: Date: ` 1`1 REINSPECTION FEE REQUIR: D. 'rior.to next inspection, fee must be paid at 6300 Southcenter Blvd', Suite 100. Call to schedule reinspection. 1 PLUMBING CONTRACTOR TO MANIFOLD DRAINS TO ONE INDIRECT WASTE r 1 LINCJ I tlnvuUI1 W. L © rr-l_r, ' r1 oi' LJ 1 LINCJ I f1nUUUM ..i�c � I I "1 I ' 1 II �I I 11 1 . 11 nre II ___ ��' -_� �%�\ 19"ill 4'-0" rT�h ii i i� ii �--�rt i "-- -If' ii 9tr� 9 ill II "r=1 fit,. II °I (.. __._• _. \ 1 1411,JL_—IA ; Vis -11,_ r ----"'Ll' ----- AN , / -1 ___ 1•�-_ �`1 I-t+tl L- Y-11� _ I II -'4_ �r===l 1%" j _ rli1 ;�I� ® �i�% _ ). 11 II �a.- C� �_� F �i J Q s ° k© I _.- r 1_- Lll II ® 4! 1 I H 4 j=-`.IIU I ® j1 dI I I I ) r� 1I I rr LL_ =-J , T-11' Ir-r`I tl ll 11 r -T -,r-----, ` r I 1 rl- - -, 1 1 1 .1" r ----'h r ILS 1 L T J+--• - I -Il--Y-LFY I L= „__= -a II- �1 - ,' ' ' 11 4 1 /1 _- F-- > I F=== k=== 4--_ a. JI l Jl L- ISI FD _ 4 1 " 4 1 _ 1 I L -' 1 I I-° 1 1 1 11 I 1 CO III Li til-� 1 �__ LL L_ I _li '111 q2. A? b II J" 32" 4._9" 1 1 1 1 1 I k---- I `.x' I 1 111 r-+ j 11 A! r 1 1 I 1 L -1 I 1- �__-L' - -1- -al -I= --11-1. I + if 1 I } 8" i I J i V I I 1r1 nl I_j I I i + ° ♦ FS ',,, i' ' G' '34" P II 1 : 11 I cp ch ® ® _- I ©A _ I t{ ' ' I 1 ��II 1 --\ + 7 1 r L---'I/.i LLQ • 1 134" 12" '7 ;' V. 'i ,� co c+1 22" ® I � �2- 1 '.. I I:S' \ I h -, I F-` � >9 1 r='�=='(I 1f1 SLEEVE DRAIN LINES THROUGH WALL ---- I --, , r11 I J _. II 1©LII:: I1 0 0 p1 1 �7 II L-� . J 1 11 I 11 1 n 1 1 II I `` i II I I�-F-J I 1F1+ I I r rT� 1 IJ ---hili I --JUL �' i 1 j _L1_+J 1 1 N __ -=q I F=== Ik== 1 i 11 __ �__= rL- =� VY! 11 26• _ r--7 dLLL _• ' i �I-_ I I --i ' - -Jrtl -i1 = Tr --9II =�= 1 ; 11 IF-- 4 -,I I la 1 11 1 1 11 I PPP111 1r=r=-(i CD 17" I-1' i l 1 #� i I iI 1-- I i d. lfil -n 11 e II M FFD 4_9" 4 - M11111 . ---J J © ° r--- _T.~- 1 -'' I 1I -4 IIII1 I " L 1 ® I a I f 1Ii 1 I I 1 ''t}''� I _ 1- 11'717-1-:77t1 I. 1 J - � 1 ALL—`_ 'GJ , � 1 © L SLEEVE LINES WALL 1 s=- = DRAT THROU T L -i rr- I ` 18"1 4'-1" I I JI `_ I I ' I F r _L.L� I I \1, � I I 12" 3" r-1- J 1 _t=� l );_--,r,4; II I I I I I iv I 1'il I 1 h-' �r L = • - MI I 1 r ___ 11� 1 �I�1 1�1 I 111 - 1 -I ��t ION �Y 11 1 it I 'I1 1 1 I1 iI_1I �IKI==I 1 1, y , �0 1 _�1 J � _ °. n � 1 1 II 11 1 1 I11III� /� L_-_. '11` 1 ® I !iJaGZiIII�t ,�� -•;11� L- .�r o IIi 1 1 J I 1.I 11 111 I� io ___ r -I1 L- N 1 _ _ =1 -el r n1 _______N_N T rill1t 11 T T1- r n._ -' Through roof penetration .% = a,. ® — ►.� n - � r -- ----1 ----� f- 1 1 I.1 I Secure typical. aift Al 1 to structure installation threw,. every Piping camp -' 8 feet fatten r II Beer Cooler Freezer ® r TT1 13-13- I �. . 1 Refrigerant 1 11 1a—ko / 1 nsulation Produce Cooler i Meat Cooler . � L' I line a g � piping Unistrut hanging g' g retail _ ` � � � , � � _ __ , � � _ UX ® . ®i ® ®i — _ ORefri Iant Scale: one LL --------- A L J 1 I I 111111111 t1l3 OZV1 ,: FLEE Copy REVIEWED FOR CODE COMPLIANCE APPROVED DEC 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DECD 52013 PERMIT CENTER Refrigeration Equipment Schedule System #1 - Outdoor R404a split system w/ mounted parts (-10°F holding temp.) 2 -year refrigeration system labor warranty (.System #1).Fieeze'r (1) Heatcraft air cooled condensing unit #MOH031 L63CBWW (-10°F) 208-230V/30/60Hz/3HP Hermetic compressor MCA=29, MOPO =30 37.75W x 28.250 x 19.75H x 2601bs. (1) Larkin low profile evaporator model #LCE694BEWMC6B-EC (-10°F) wi EC motors (1.1A) &electric defrost (7.8A) wi mounted thermostat, solenoid valve &TXV 208-230V/10/60Hz 45.5W x 13.43750 x 14.9375H x 481bs. Includes (1) ea. Mounted fuse disconnect (1) ea. SOK (1) ea. Adjustable low pressure control 4 -year extended compressor warranty (System #1 ) System #2 - Outdoor R404a split system w/ mounted parts (35°F holding temp. 2 -year refrigeration system labor warranty (Systems nProduce Cooler (1) Heatcraft air cooled condensing unit #MOH01OX63CBWWF (35°F) 208-230V/30/60Hz/1 HP Hermetic compressor MCA=20, MOPO =20 23.75W x 28.250 x 17.25H x 1731bs. (1) Larkin low profile evaporator model #LCA690AEWMC6B-EC (35°F) wi EC motors (2A) &air defrost wi mounted thermostat, solenoid valve &TXV 115V/10/60Hz 45.5W x 13.43750 x 14.9375H x 491bs. Includes (1) ea. Mounted fuse disconnect (1) ea. Adjustable low pressure control 4 -year extended compressor warranty (System #2) System #3 - Outdoor R404a split system w/ mounted parts (30°F holding temp.) 2 -year refrigeration system labor warranty (Sy0e6143);meat Cooler (1) Heatcraft air cooled condensing unit #MOH015X63CBWWF (30°F) 208-230V/30/60Hz/1.5HP Hermetic compressor MCA=20, MOPO =20 37.75W x 28.250 x 17.25H x 2301bs. (1) Larkin low profile evaporator model #LCE6120BEM6CMB-EC (30°F) wi EC motors (1.6A) &electric defrost (11.7A) wi mounted thermostat, solenoid valve &TXV 208-230V/10/60Hz 61.5W x 13.43750 x 14.9375H x 601 bs. 4 -year extended compressor warranty (System #3) M13- 027?1 -004rite 11,1f REV9puPNCEWED FOR CODE APPROVE DEC 13 2013 City of T�kwil�► BUILDING DIVISION i-iE aE1VED Y OF TUKWILA DEC 0 ,5 2013 PERMIT CENTER Refrigeration Equipment Schedule System #4 - Outdoor R404a split system w/ mounted parts (32°F holding temp.) 2 -year refrigeration system labor warranty (ystetna#_4)BeerCooler (1) Heatcraft air cooled condensing unit #MOH020X63CBWW (32°F) 208-230V/30/60Hz/2HP Hermetic compressor MCA=24, MOPD =25 37.75W x 28.25D x 17.25H x 2301bs. (1) Larkin low profile evaporator model #LCE665BEWMCM6MK-EC (master) (32°F) wl EC motors (1.1A) &air defrost wl mounted thermostat, solenoid valve &TXV 208-230V/10/60Hz 45.5W x 14.875D x 15H x 431bs. (1) Larkin low profile evaporator model #LCE665BETXV6K-EC (slave) wl EC motors (1.1A) &air defrost wl mounted TXV 208-230V/10/60Hz 45.5W x 14.875D x 15H x 431bs. Includes (1) ea. mounted fuse disconnect (1) ea. SDK (1) ea. Adjustable low pressure control 4 -year extended compressor warranty (System #4 ) • PERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-0227 PROJECT NAME: BUFFALO WILD WINGS SITE ADDRESS: 295 TUKWILA PKWY X Original Plan Submittal Response to Incomplete Letter # DATE: 12-05-13 Response to Correction Letter # Revision # After Permit Issued D PARTMENTS: AillA ii-ko"c) Bui ing 'vision Fire Prevention Planning Division Public Works n Structural Permit Coordinator A DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-10-13 Complete Comments: to Incomplete Not Applicable Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 0 Fire ❑ Ping 0 PW 0 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 01-07-14 Not Approved (attach comments) n DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 AMBIENT CONTROL CO INC • Washington State Department of Labor & Industries Page 1 of 2 AMBIENT CONTROL CO INC Owner or tradesperson WALL, DENA Principals WALL, DENA ROBERT (BOB) WALL GILBERT SALINAS Doing business as AMBIENT CONTROL CO INC WA UBI No. 601 081 069 1411 RST NW AUBURN, WA98001-3506 253-876-9933 KING, County Business type Corporation Governing persons DENAJOWALL License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. ........... ............. Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. AMBIECC101 PW Effective — expiration 10/16/1990 —10/25/2015 Bond OLD REPUBLIC SURETY CO Bond account no. YLI227438 Received by L&I 10/25/2001 Insurance .... .................. Continental Western Ins Co Policy no. CWP2945945 Received by L&I 09/17/2013 $6,000.00 Effective date 10/16/2001 $1,000,000.00 Effective date 10/16/2011 Expiration date 10/16/2014 httns://secure.lni.wa. aov/verify/Detail.aspx?UBI=601081069&LIC=AMBIECC 1 O 1 PW&S... 12/30/2013 GENERAL NOTES 1. GENERAL CONTRACTOR IS RESPONSIBLE FOR SEALING ROOF PENETRATIONS. 2. HVAC VENDOR TO PROVIDE ROOF CURBS AND VENDOR IS RESPONSIBLE FOR PROVISION/ COORDINATION OF ROOF PENETRATIONS REQUIRED FOR EQUIPMENT INSTALLATION. 3. FLASH ROOF VENT PIPES, SEE 01/A301. 4. APPROXIMATE LOCATION OF SATELLITE DISH PROVIDED BY AV CONTRACTOR. COORDINATE WITH JOIST MANUFACTURER. G.C. TO PROVIDE 4x4 WD SLEEPERS AT ALL CONDENSING UNIT AND SATELLITE DISH LOCATIONS — SEE DETAIL 3/A301 5. INSTALL ROOF TOP MOUNTED MECHANICAL UNITS ON PREFINISHED METAL CURB WITH TREATED WOOD NAILER. REFER TO DETAILS AS INDICATED ON THIS SHEET. SEE MECHANICAL DRAWINGS FOR NUMBER, SIZE, HEIGHT, WEIGHT, AND FINAL LOCATION OF ROOF TOP MOUNTED MECHANICAL EQUIPMENT. 6. VENT PIPES TO BE 10" MINIMUM FROM AIR INTAKE. 7, ROOF PENETRATIONS, CURBS, AND SLEEPERS TO BE INSTALLED BY LANDLORD APPROVED ROOFER. REFER TO INFORMATIONAL DETAILS ON A301. 8. NEW DURO—LAST ROOFING TO BE INSTALLED BY MANUFACTURER APPROVED UCENSED ROOFING CONTRACTOR. REFER TO DETAILS AS INDICATED ON THIS SHEET. SPECIFICATIONS FOR NEW ROOF CRICKETS PER MANUFACTURER'S RECOMMENDATIONS. 9. ALL GAS PIPING TO ROOF SHALL BE PAINTED TO MATCH ADJACENT FINISH. 10 GC TO PROVIDE POWER AND BLOCKING FOR ALL BUILDING SIGNAGE. COORDINATE WITH SIGN VENDOR. GC TO PROVIDE POWER TO DESIGNATED TRANSFORMER LOCATIONS FOR LED STRIP UGHIING SYSTEM — SEE MEP DRAWINGS AND COORDINATE FINAL LOCATION WITH SIGN VENDOR 01/A102 RC)OF LEGEND (N) ROOF HATCH (N) ROOF DRAIN & OVERFLOW (N) ROOFING MEMBRANE 0/ TAPERED INSULATION, SEE 14/A301 (N) ROOF DECK & ROOFING MEMBRANE, SEE A102 FLOOR PLAN KEYNOTE, SEE KEYNOTE LEGEND WINDOW TAG, SEE WINDOW SCHEDULE ON A800 G T PLAN NORTH TRUE NORTH N O UPPER ROOF PLAN SCALE: 1/4"=1'-0" KEYED NOTES c RD0FTOP HVAC UNIT, MOUNT ON PREFINISHED METAL CURB — REF 02/A301, COORDINATE STRUCTURE — SEE MECH DWGS. SEE MEP ROOF PLANS FOR LIGHTS AND OUTLETS AT UNITS ® K,'TCHEN EXHAUST SYSTEM, SEE MECH DWGS (N) ROOF HATCH OCONDENSING UNIT FOR WALK—IN BOXES, KITCHEN EQUIPMENT VENDOR TO COORDINATE LOCATION, FINAL HQOK—UP BY GC. REFER TO 03/A301 FOR TYP. SUPPORTS ®C)NDENSING UNIT FOR ICE MAKER, KITCHEN EQUIPMENT VENDOR TO COORDINATE LOCATION. RUN R=FRIGERANT UNES ABOVE CEIUNG IN KITCHEN, FINAL HOOK—UP BY GC. REFER DETAIL 03/A301 PROVIDE ROOF CRICKET AT AC UNIT FOR DRAINAGE APPROXIMATE LOCATION OF SATELLTE DISH PROVIDED BY A/V CONTRACTOR. SEE GENERAL NOTE 5. �8 HDODED PAN FOR REFRIGERANT LINES, ETEC, ETC — REF 13/A301 — VERIFY FINAL LOCATION WITH EQUIPMENT O21" HIGH OPENING IN WALL FOR DRAINAGE SHOWN HATCHED. lO NE• W ROOF DRAIN, SEE DETAIL 06/A301 11 DCORAIIVE STEEL CHANNEL, SEE 6/A104. PAINT PER A100 & A101, S.S.D. 12 N• a USED 13 (f) SIGNAGE, SEE A100 & A101 14 DIGONAL BRACE, SSD 15 GARD RAIL, SEE DETAIL 16/A301 16 ROF SCREEN, SEE DETAIL 8/A301 11 1 I 1 11 11 1 11 1 1 r 46'-1" r— L_ 14 7'-7 1/4" 7'-0" 36'-10 3/4" 7'-0" 11 II 1 I 11 11 11 I I II II II II 11 II 1 II I I I I Il I I it 1 11 11 11 11 11 11 11 ll II II II 11 I1 11 11 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 13 2013 City of Tukwila BUILD DING DIVISIO 7,—ON 8' 3 1/2" (AC)2 520 LB5 120 GFM OA X60 MBH r _ i J 1 ' 11 1 " 1 1 ' 1 1 '\� 1 - \� 1 O - r . 11011111111P I towiliN I,- - - ---1 . , I , O `• 11• ., I �'Il 1 Iri) tllew 1, x400 a.m.* r to , F-,--1-7 , ---, 1 .„- tio o _(Opg) r ,__ - J �1 7'-7 1/4" 7'-0" 36'-10 3/4" 7'-0" 11 II 1 I 11 11 11 I I II II II II 11 II 1 II I I I I Il I I it 1 11 11 11 11 11 11 11 ll II II II 11 I1 11 11 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 13 2013 City of Tukwila BUILD DING DIVISIO 7,—ON 8' 3 1/2" (AC)2 520 LB5 120 GFM OA X60 MBH r _ i J 1 ' 11 1 " 1 1 ' 1 1 '\� 1 - \� 1 O - 1600 LB5 630 GFM OA 130 MBH i L- r 7-1 111 -o i V". i 7 i \ OPEN i i 111 1 i L \ i i T r r . 11011111111P I H-1 II i 1 i 1 O `• 11• ., I �'Il 1 1600 LB5 630 GFM OA 130 MBH i L- r 7-1 111 -o i V". i 7 i \ OPEN i i 111 1 i L \ i i T r (AG) 1600 LB5 C. --M ciAi 130 MBH 4r -- 4r - AC)3 2520 LB5 IQ20 GFM OA 260 88 0 L N O 10 TRUE NORTH PLAN NORTH ROOF PLAN SCALE: 1/4"=1'-0" I4(3O2x7 o1/A102 RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 2410 Mariner Square Loop Alameda, CA 94501 Tel 510 865 8663 Fax 510 865 1611 225 TUKWILA PARKWAY TUKWILA, WA 98188 DO NOT SCALE DRAWINGS CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS -NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO BEGINNING CONSTRUCTION Drawings and written material appearing herein constitute origianl and unpublished work of the Architect and may not be d,plicated ,sed or disclosed without written consent of the Architect OMBH ARCHITECTS -2013 C� rY D w 0 re) to DESCRIPTION DEMO, PLUMBING & HEALTH SUBMITTALS O Z Z 0< O -i rr PROJECT NUMBER 46997 SHEET NUMBER A300 r . 11011111111P I `• :ITQ: FC. -1-2-1 TC. --,-711 Iri) ---, 1 .„- OVA* .\ 1 1 ,. `\ 1 4110 4iiil I �1 1%1 'tritr► �,:�►S.I V 1 (AG) 1600 LB5 C. --M ciAi 130 MBH 4r -- 4r - AC)3 2520 LB5 IQ20 GFM OA 260 88 0 L N O 10 TRUE NORTH PLAN NORTH ROOF PLAN SCALE: 1/4"=1'-0" I4(3O2x7 o1/A102 RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 2410 Mariner Square Loop Alameda, CA 94501 Tel 510 865 8663 Fax 510 865 1611 225 TUKWILA PARKWAY TUKWILA, WA 98188 DO NOT SCALE DRAWINGS CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS -NOTIFY ARCHITECT OF ANY DISCREPANCIES PRIOR TO BEGINNING CONSTRUCTION Drawings and written material appearing herein constitute origianl and unpublished work of the Architect and may not be d,plicated ,sed or disclosed without written consent of the Architect OMBH ARCHITECTS -2013 C� rY D w 0 re) to DESCRIPTION DEMO, PLUMBING & HEALTH SUBMITTALS O Z Z 0< O -i rr PROJECT NUMBER 46997 SHEET NUMBER A300