Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-0228 - BOEING #11-14 - REPLACE ROOF TOP UNIT
BOEING #11-14 11201 TUKWILA INTERNATIONAL BLVD M13-0228 Parcel No: Address: Project Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 0923049155 11201 TUKWILA INTERNATIONAL BLVD BOEING #11-14 Permit Number: M13-0228 Issue Date: 1/24/2014 Permit Expires On: 7/23/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: BOEING COMPANY THE PO BOX 3707 M/C 20-00 PROPERTY TAX DEPT, SEATTLE, WA, 98124 AMY HIGHTOWER 20452 84 AVE S , KENT, WA, 98032 APOLLO SHEET METAL INC PO BOX 7287 , KENNEWICK, WA, 99336 APOLLSM187MK 11 I Phone: (253) 872-5151 Phone: (509) 586-1104 Expiration Date: 4/9/2014 DESCRIPTION OF WORK: REPLACEMENT OF (2) ROOFTOP AIR HANDLING UNITS WITH ASSOCIATED PIPING AND HVAC TO REPLACE Valuation of Work: $97,002.00 Type of Work: REPLACEMENT Fuel type: ELECT Fees Collected: $1,343.63 Electrical Service Provided by: Water District: Sewer Distric: Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: oihtiUH I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to th conditio attached to this permit. Signature: Print Name: Date: This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***MECHANICAL PERMIT CONDITIONS*** 2: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 3: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL 0702 SMOKE DETECTOR TEST CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TulcwilaWA.gov Mechanical Permit No. 1-4 Project No. Date Application Accepted: 1 S -( 3 Date Application Expires: Ep — �� —1 9 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: 11201 Tukwila International Blvd Suite Number: Floor: Tenant Name: Boeing Company — 1 1-1 <% 1314 1' New Tenant: ❑ Yes ® ..No PROPERTY OWNER Name: Boeing Commercial Airplane Seattle District Address: P.O. Box 3707 M/S: 1W-10 City: Seattle State: WA Zip: 98124 CONTACT PERSON — person receiving all project communication Name: Amy Hightower Address: 20452 84th Ave S City: Kent State: WA Zip: 98032 Phone: (253) 872-5151 Fax: (253) 872-5930 Email: amy.hightower@apollomech.com MECHANICAL CONTRACTOR INFORMATION Company Name: Apollo Mechanical Contractors Address: PO Box 7287 City: Kennewick State: WA Zip: 99336 Phone: (509) 586-1104 Fax: (509) 582-6590 Contr Reg No.: APOLLSM 1 87M Exp Date: 05/01/2014 Tukwila BrinessJ.icense No . 0 ii � I � f� G I 0 L Valuation of project (contractor's bid price): $ 97,002 Describe the scopof work in detail: Replacement ofroof. top air handling unitswith associated piping and HVAC to replace Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas ❑ Other: H:\Apphcattons\Forns-Applications On Line \2011 Apphcattons\Mechanical Permit Application Revised 8.9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 2 Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm 2 Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 16 Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 1 ' AUTH ' ' ED Signature: Date: , /•!l 6/aa/3 Print Name:./ MS/ N1cN1o14/E12 Day Telephone:( 53) 872 - 515, /fen/ I�tIA 98434 City State Zip Mailing Address: A) 4/3a eyr""Are.S: H:'Applications\Forms-Applications On Line \201 I Appltcations\Mechamcal Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY I PAID M13-0228 Address: 11201 TUKWILA INTERNATIONAL BLVD Apn: 0923049155 $1,074.90 MECHANICAL PERMIT FEE PERMIT ISSUANCE BASE FEE TOTAL FEES PAID BY RECEIPT: R930 R000.322.100.00.00 R000.322.100.00.00 $1,074.90 $1,042.40 $32.50 $1,074.90 Date Paid: Friday, January 24, 2014 Paid By: APOLLO SHEET METAL INC Pay Method: CREDIT CARD 06283C Printed: Friday, January 24, 2014 1:55 PM 1 of 1 CRWYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS ACCOUNT QUANTITY PAID 268.73 M 13-0228 Address: 11210 TUKWILA INTERNATIONAL BLVD Apn: 0923049152 $268.73 MECHANICAL $268.73 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R265 8000.322.102.00.00 $268.73 $268.73 Date Paid: Thursday, December 05, 2013 Paid By: AMY HIGHTOWER APOLLO SHEET MET Pay Method: CREDIT CARD 01190C Printed: Thursday, December 05, 2013 3:06 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD. Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA.BUILDING DIVISION . 6300 Southcenter Blvd., #100, Tukwila. WA 98188. (206) 431-3670`' Permit Inspection Request Line (206) 431-2451 iitr3 -02-4 Projects tType 6e A& 1(-14 of Inspection: rtes. g /OA L Address: 1 / il0 i !� Date Called: --- Special Instructions: ji Date Wanted:";,?........m., Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Litokpj‘r Inspecrfor: Date: n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be. paid at.6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit M13'ozzB INSPECTION NO. PERMIT NO. CITY OF TUKW.ILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwi a. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proj ct: Type of Insp ction: Adddre/ss: �L Date Called: Special Instructions: /. Date Wanted:/ 3- f a,,rof " 1 p.m. Requester A�` /_� Pone S .9 7.;? - 043& Approved per applicable codes. Corrections required prior to approval. COMMENTS: 0 V-- wfri 1 .V 3. REINSPECTION FEE REQUIRED. Prior to next inspection, fee: must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Insp=ctor: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd.,. #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206):431-2451 MI3 -azg Project. e 0,e.,,A.6 )(--`I4 Typ of Inspection:7_1U i�-J()614- Address: 1(.1 Date Called: Special Instructions: 7 Date Wanted: 3 - r tic i P.m. Requester: Ph ceb 9 -'7 2 7 , O (3 Approved.per applicable codes.. EJ Corrections required prior to approval. COMMENTS: Date: _ 1g REINSPECTION FEE REQUIRED. Prior to nextinspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100.. Call to schedule reinspection. 71M IT ��..,.-:m1 ? I E rte• ❑ M, ti\pectrical Xdumbing Gas Piping c'I cf Tukwila EU i_..i'> s ; DIVISION LOCATION BUILDING x',91-14 DUWAMISH OFFICE PARK MAJOR PASSENGER ELEVATOR REPAIR VICINITY vAP 1 1 / /;, e / -.97 SOUTH 11 sirE STREET q 4 // • /1%,% / DESCRIPTION OF WORK: REPLACE EXISTING ELEVATOR MACHINE ROOM VENTILATION ONLY COOUNG WITH NEW MECHANICALLY COOLED HVAC SYSTEM ALONG WITH MISCELLANEOUS OTHER WORK. PROJECT COST: SXX,XXX.XX CONTRACTOR: ADDRESS AND TELEPHONE NUMBER (WHEN KNOWN) SITE ADDRESS: 11201 TUKWILA INTERNATIONAL BLVD. OWNER: BOEING COMMERCIAL AIRPLANE SEATTLE DISTRICT P.O. BOX 3707, 4- 12w -CORRECTION SEATTLE, WA.981224-2207 OWNER CONTACT: MARK CLEMENT 206-6171-23} KING COUNTY PARCEL NO. 0923049155 1� TTTT BB i 1. PROVIDE POST CONSTRUCTION COMMISSIONING AND COMPLETION REQUIREMENTS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE, SECTION C408.1 AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE SPECIFICATION SECTIONS 23 08 00 AND ALL OTHER APPLICABLE SPECIFICATION SECTIONS. 2. BALANCE ALL HVAC SYSTEMS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY a CODE, GENERALLY ACCEPTED ENGINEERING STANDARDS AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE SPECIFICATION SECTION 23 05 93 AND ALL /I OTHER APPUCABLE SPECIFICATION SECTIONS. �I 3. PROVIDE CONTROLS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE, `I SECTION C403.2.4 AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE TEMPERATURE CONTROL SPECIFICATION SECTIONS AND ALL OTHER APPUCABLE SPECIFICATION SECTIONS. 4. ALL SYSTEMS HAVE BEEN SIZED ACCORDING TO THE WASHINGTON STATE ENERGY CODE, SECTION C403.2.2. (D4./ 7 1110 ;� /�//// PROJECT AREA / / / 0 REVISIONS No changes shall be made to the scope of work without prior approval of uKwua tsunaing u!vision. • NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY GROUE:approval is subject to errors and omisslors. Approval of construction documents does not authorize the violation of any adopted code or ordnance. Receipt of approved Field • and >; I Is akn ed CODESUMNAR BUILDING CODE: UBC 1997 EDITION, AS ADOFTED�`' CITY OF TUKWILACODE SEISMIC ZONE: 3 OCCUPANCY GROUP: 6 CONSTRUCTION TYPE: - TOTAL BUILDING AREA: SQ FT CONSTRUCTION AREA: 924 SQ FT BUILDING HEIGHT: FT STORIES: 7� Ire B1�pE v IL u F COMPLIA APPROVED JAN3 2 2014 City of u II BUILDING I IS PROJECT SUMVARY DESCRIPTION OF WORK: REPLACE EXISTING ELEVATOR MACHINE ROOM VENTILATION ONLY COOUNG WITH NEW MECHANICALLY COOLED HVAC SYSTEM ALONG WITH MISCELLANEOUS OTHER WORK. PROJECT COST: SXX,XXX.XX CONTRACTOR: ADDRESS AND TELEPHONE NUMBER (WHEN KNOWN) SITE ADDRESS: 11201 TUKWILA INTERNATIONAL BLVD. OWNER: BOEING COMMERCIAL AIRPLANE SEATTLE DISTRICT P.O. BOX 3707, 4- 12w -CORRECTION SEATTLE, WA.981224-2207 OWNER CONTACT: MARK CLEMENT 206-6171-23} KING COUNTY PARCEL NO. 0923049155 1� TTTT ✓ ✓ ✓ ENERGY NOTES 1. PROVIDE POST CONSTRUCTION COMMISSIONING AND COMPLETION REQUIREMENTS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE, SECTION C408.1 AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE SPECIFICATION SECTIONS 23 08 00 AND ALL OTHER APPLICABLE SPECIFICATION SECTIONS. 2. BALANCE ALL HVAC SYSTEMS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY a CODE, GENERALLY ACCEPTED ENGINEERING STANDARDS AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE SPECIFICATION SECTION 23 05 93 AND ALL /I OTHER APPUCABLE SPECIFICATION SECTIONS. �I 3. PROVIDE CONTROLS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE, `I SECTION C403.2.4 AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE TEMPERATURE CONTROL SPECIFICATION SECTIONS AND ALL OTHER APPUCABLE SPECIFICATION SECTIONS. 4. ALL SYSTEMS HAVE BEEN SIZED ACCORDING TO THE WASHINGTON STATE ENERGY CODE, SECTION C403.2.2. SOV A AB REVISION KITCHENETTE UPGRADES ADDENDUM +2 CNr-S-12107 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 PERMIT COMMENT REVISION BY KCP FS DAM SYM REVISION ar *PROVED DATE AIC 10.17.12 11.08.13 01.10.14 I g)t_ArsrezAr9° ACCEPTABILITY SPEOFI 1145G0ESIpIKW lISANAIFYWORVED .mawR L'itED INCINLAN APPROVED BY DEPT. DATE CE ON (E) INDICATES EXISTING CONDITION, DIMENSION OR DATUM. VERIFY ALL. EXISTING CONDITIONS, DIMENSIONS, DATUMS AND LEVELS ON PROJECT PRIOR TO COMMENCEMENT OF WORK. 2. CONTRACTOR SHALL USE DIMENSIONS SHOWN ON DRAWINGS AND ACTUAL FIELD MEASUREMENTS. CONTRACTOR SHALL NOT SCALE DRAWINGS. NOTIFY ARCHITECT IF ANY DISCREPANCIES ARE FOUND. 3. DO NOT SIGNIFICANTLY VARY OR MODIFY THE WORK SHOWN EXCEPT UPON WRITTEN INSTRUCTION FROM THE ARCHITECT. 4. GENERALLY, PLAN DIMENSIONS SHOWN ARE TO FINISH OPENING, FINISH FACE OF CONCRETE AND FINISH FACE OF WALL. DIMENSIONS NOTED 'CLEAR' INDICATE DIMENSIONS TO FINISH MATERIAL UNLESS OTHERWISE NOTED. 5. GENERAL CONTRACTOR SHALL COORDINATE WITH ALL TRADES, INCLUDING DESIGN BUILD DOCUMENTS TO VERIFY SIZE, LOCATION AND GENERAL CONSTRUCTION OF THOSE ITEMS. 6. CONTRACTOR SHALL VERIFY LOCATION OF ALL EXISTING UTIUTIES AND PROTECT AS REQUIRED PRIOR TO COMMENCEMENT OF WORK. 7. CONTRACTOR SHALL MAINTAIN CURRENT RECORD DRAWINGS FOR ARCHITECTS PERIODIC REVIEW. 8. THROUGHOUT THE DRAWINGS ARE ABBREVIATIONS THAT ARE IN COMMON USE. THE UST OF ABBREVIATIONS PROVIDED IS NOT INTENDED TO BE COMPLETE OR REPRESENTATNE OF CONDITIONS OR MATERIALS ACTUALLY USED ON THIS PROJECT. THE ARCHITECT WILL DEFINE THE INTENT OF ANY IN QUESTION. 9. AS -BUILT DRAWINGS ARE BASED ON RECORD DRAWINGS AND MAY BE INCLUDED FOR REFERENCE AS TO THE SCOPE OF WORK ONLY. IT IS RECOMMENDED THAT THE CONTRACTOR VISIT PRIOR TO BID, EXAMINE EXISTING CONDITIONS AND INCLUDE ALL DEMOLITION REQUIREMENTS FOR THE SCOPE OF THE PROJECT IN THE CONTRACT SUM. NO ADDfT1ONAL PAYMENTS WILL BE MADE FOR FAILURE TO OBTAIN ALL REQUIRED INFORMATION AND MAKE KNOWN ANY INACCURACIES BEFORE BID. 10. PROVIDE SAFETY BARRIERS DURING CONSTRUCTION. 11. A MAXIMUM OF (1) BREAK ROOM IN EACH TOWER TO BE UNDER CONSTRUCTION AT ONE TIME, COORDINATE WITH OWNER. 12. WORK HOURS TO BE DETERMINED BY BOEING. 13. ALL PLUMBING WORK TO MEET 2009 IPC AND LOCAL AHJ. RECEIVED CITY OF TUKWILA JAN 1 3 2014 PERMIT CENTER MI5 -0212g ISSUED FOR CONSTRUCTION iiconsulting engineers Seattle, Washington Solutions & Service COVER SHEET CIRRDNY 812012 W1696197 SYMBOL DATE B 11.08.13 'CHECKED - APPROVED APPROVED 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14 SHEET GO JOB NO. `uuwamish_Cover.dwg ARCHITECTURAL MASTER COL. X-X/X-X DUWAMISH DAG NO. 11 -014 -GO a 19 ). DRAWING INDEX 60X DESIGN REVIEW - 08.28.13 95X DESIGN REVIEW 10.03.13 ISSUED FOR CONSTRUCTION DRAWING NUMBER SHEET REV DRAWING TITLE 11-014—GO GO B COVER • • 11-014-01 G1 A DRAWING INDEX • • 11-14N—G1a Gla — SYMBOLS. ABBREVIATIONS & GENERAL NOTES • • 11-14N—PA11 PA11 A PARTIAL PENTHOUSE FLOOR PLAN • • 11-14N—RFA11 RFA11 A ROOF PLAN • • 11-14N—A352 A352 F SCHEDULES AND FINISHES • 11-14N—A509 A509 A DETAILS AND WALL TYPES • 11-14N—A510 A510 A DETAILS AND WALL TYPES • 11-14S—A501 A501 A DETAILS AND WALL TYPES • 11-14S—PAM PAI 0 A PARTIAL PENTHOUSE FLOOR PIAN • • 11-14S—RFA10 RFA10 B ROOF PLAN • • 11-014N—S160 S160 A SOUTH PARTIAL ROOF PUN • 11-014N-5160 S160 A NORTH PARTIAL ROOF PLAN • 11-014N/S-5504 5504 A DETAILS AND SECTIONS • 11-014—M2A M2A H HVAC EQUIPMENT SCHEDULES • 11-014-1420 M2G E EQUIPMENT SCHEDULE — HVAC • • 11-0145—PM1OR PM1OR J PENTHOUSE HVAC PIAN AND ELEVATION — REMOVAL • • 11 —014S—RFM3R RF1/3R A SOUTH COMPOSITE MECHANICAL ROOF PLM — REMOVAL • • 11-014S—PM10 PM10 J PENTHOUSE HVAC PIAN AND ELEVATION • • 11-0145—RF143 RF1,13 A SOUTH COMPOSITE MECHANICAL ROOF PLAN • • 11-0145—M534 M534 8 SOUTH COMPOSITE MECHANICAL ROOF PLAN — 11-14S • 11-014N—P111OR PM1OR H NORM HVAC SYSTEMS — PENTHOUSE — REMOVAL • • 11-014N—RFU11R RD/11R B NORM COMPOSITE MECHANICAL ROOF PUN — REMOVAL • • 11-14N—M500R MSOOR D DETAILS. SECTIONS & ELEVATIONS — PENTHOUSE — REMOVAL • • 11-014—M524R M524R D DETAILS, SECTIONS & ELEVATIONS — REMOVAL 11-014N—PU10 P810 H NORTH HVAC SYSTEMS — PENTHOUSE • • 11-014N—RF811 RFM11 B NORM COMPOSITE MECHANICAL ROOF PUN • • 11-014-8453 11453 D HVAC PIPING DETAILS — NORM TOWER 11-14N-8500 8500 D DETAILS. SECTIONS & ELEVATIONS — PENTHOUSE • • 11-014-11524 M524 D DETAILS. SECTIONS & ELEVATIONS • • 11.145—PE11OR PE11OR A SOUTH TOWER PENTHOUSE 277/480 VOLT PLAN — REMOVAL • • 11.145—PE60 PE60 E SOUTH TOWER PENTHOUSE 120/208 VOLT PLAN • • 11.145—PEI10 PEI10 A SOUTH TOWER PENTHOUSE 277/480 VOLT PLAN • • 11.145-5E60 5E60 Y SOUTH TOWER FIFTH FLOOR 120/208 VOLT PIAN • 11.14N—PE11OR PE11OR C NORTH TOWER PENTHOUSE 277/480 VOLT PLAN — REMOVAL • • 11.14N—PE60 PE60 A NORTH TOWER PENTHOUSE 120/208 VOLT PUN • • 11.14N —PEI 10 PEI10 C NORTH TOWER PENTHOUSE 277/480 VOLT PLAN • • 11.14N -5E61 5E61 U NORTH TOWER FIFTH FLOOR 120/208 VOLT PLAN • 11.14—E502 E502 A FIRE ALARM AND SMOKE DETECTORS DETAILS, SECTIONS AND ELEVATIONS • DRAWING INDEX DRAWING NUMBER SHEET REV DRAWING TITLE LEGEND REV NFC FRO A REVIEWED FOR CODE COMPLIANCE ED JAN 2 3 2014 City of Tukwila ' BUILDING DIVISION 95% DESIGN REVIEW DOT INDICATES DRAWING IS INCLUDED IN SUBMITTAL NO DOT INDICATES DRAWING IS NOT INCLUDED IN SUBMITTAL NOT FOR CONSTRUCTION FOR REFERENCE ONLY DRAWING REVISION — SEE SPECIFIC DRAWING FOR NATURE OF REVISION RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER SYM INN APPROVED DUE SYN ID DUE A 11-14 UMOR PASSENGER ELEVATOR REPAIR W1696197 FSR 10.03.13 ACCEPTABIUTY THIS DESIGN MND OR el__ArArAv9's SPECIFICATION s APPROVED BY DM. DATE APPROVED APPROVED SUBTITLE DRAWING INDEX 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14 MECHANICAL MASTER COL • FSi consulting engineers Seattle, Washington CURRENT REV6gN W1696197 Solutions & Service SOL A DATE 10.03.13 sHw G1 JOB NO. COMP NO. DUWAMISH 000 N0. 11-14—G1 SYMBOLS ABBREVIATIONS GENERAL NOTES AREA OF WORK INDICATIONS NOTE: SEE STRUCTURAL, MECHANICAL AND ELECTRICAL ITEMS AB ANCHOR BOLT LAV LAVATORY 1. ALL WORK SHALL COMPLY WITH APPUCABLE CODES AND ORDINANCES. 1. DRAWINGS WITH CLOUDED AREAS INDICATE THE AREA OF WORK FOR THIS PROJECT. ELECTRICAL FOR ADDITIONAL SYMBOLS. DIAGRAMATIC ONLY-SEE ELECTRICAL FOR ACTUAL FIXTURE TYPES. COLUMN (RID ACOUS ACOUSTICAL ADJ ADJACENT AFF ABOVE ORM FL ANDD ANODIZED LG LONG UV LONG LEG VERTICAL LP LOW POINT MAX MINIMUM 2. CONFIRM BUILD8I6 GRID LAYOUT AND EXISTING WALL LOCATIONS AND VERIFY ALL DIMENSIONSOOR AND EXISTING CONDITIONS ON THE PROJECT PRIOR TO PROCEEDING CH THE WORK. ANY DISCREPANCIES 2. DRAWINGS INDICATED AS REFERENCE ONLY SHOW EXISTING CONDITIONS TO REIN' 3DRA WING$ WITHOUT CLOUDS OR "REFERENCE ONLY INDICATIONS ARE TO O AP ACOUSTICAL PANEL MFR MANUFACTURER ARE TO BE REFERRED TO BOEING CM FOR RESOLUTION BE ALL NEW WORK, O 1 2' X 4' FLOURESCENT UGHT FIXTURES AT ACOUSTICAL TILE. ACT ACOUSTICAL CEIUNG 111E MIN MINIMUM BEFORE CONSTRUCTION TAKES PLACE. MASONRY OPENING AWC ACOUSTICAL WALL COVERING MOIAM WHERE EXISTING WORK IS DAMAGED, CUT OR DEFACED AS A ELEVATION DATUM 1 1 3 PERFORMANCE OF NEW WORK, THE CONTRACTOR IS ® 1' X 4' FLOURESCENT UGH' FIXTURES ELEVATION BUILDING SECTION m EXIT EIGHT (W/ DIRECTION AS INDICATED) WALL SECTION C` 10' INTERCOM SPENCER B/ BOTTOM OF BD BOARDTO BIT BITUMINOUS BLKG BLOCKING BLDG BUILDING N MID MASOTED MIL METAL NIC NOT IN CONTRACT RESULT OF PATCH AND REPAIR SAME TO MATCH ADJOINING SURFACES. REPAIRED FINISHES SHALL BE EXTENDED TO THE NEAREST VISUAL BREAK UNES SUCH AS CORNERS, CEILING UNES, TOP OF BASE OR SIMILAR. PROVIDE CLOSURE, MEETING THE REQUIREMENTS OF GOVERNING �t� 1111 • HOLE IN TILE FOR POWER POLE SECTION/DETAIL DESIGNATION 4k RECEPTACLE ISI 1200, 1 PHASE, — DRAWN ON SHEET NUMBER 4-PLLX, NEMA 5-15 Fl— * RECEPTACLE - 15&1200, 1 PHASE, DUPLEX, NEMA 5-15' REFERENCED ON SHEET NUMBER RECEPTACLE 2080 0CMU MECHANICAL ITEMS BM BEAM BOT BOTTOM BRDG BRIDGING BRG BEARING CONC BU( CONCRETE BLOCK CLG COLING CLEAR CONCRETE MASONRY CPT CARPET COL COLUMN OFCI OWNER FURNISHED/CONTRATOR INSTALLED 011 OWNER FURNISHED AND INSTALLED OVHD OVERHEAD OPNG OPENING OC ON CENTER PARTITION PC PRECAST UNIT PERIM PERIMETER PL PIRG PLUM 4. FIRE AUTHORITIES, BETWEEN ALL FIRE RATED FLOORS, SHAFTS AND BUILDING PARTITIONS AND ALL PENETRATING DUCTS, PIPES, CONDUIT, MECHANICAL, ELECTRICAL, AND OTHER ITEMS. 5. THE CONTRACTOR IS RESPONSIBLE FOR REVIEW OF THE STRUCTURAL, MECHANICAL AN0 ELECTRICAL DRAWINGS FOR CUTTING AND PATCHING MS WORK WITHIN THE BUILDING BEYOND THE S ASSOCIATED OF THE ARCHITECTURAL DRAWINGS. 6. THE CONTRACTOR SHALL CONSULT PLANS FOR ALL TRADES AND PROVIDE AIL FOR DETAIL DESIGNATION DIAGRAMATIC ONLY-SEE MECHANICAL CONC CONCRETE CONST CONSTRUCTION N PENETRATION PEEN P01 PRESSURE PRESERVATIVE TREATED OPENINGS THROUGH NEW OR EXISTING CONSTRUCTION DUCTS, PIPES, CONDUITS, CABINETS, AND EQUIPMENT, AND SHALL VERIFY FOR DETAIL DESIGNATION ACTUAL FIXTURE TYPES. SUPPLY AIR DIFFUSER CONT CONTINUOUS CONT JT CONTROL JOINT CONTR CONTRACTOR PREF1N PREHNISHED PROV PROVIDE PSF POUNDS PER SOUARE FOOT SIZES AND LOCATIONS OF OPENINGS. 7. THE CONTRACTOR SHALL VERIFY ALL ROUGH-IN DIMENSION REQUIREMENTS FOR EQUIPMENT FURNISHED AND INSTALLED BY )000( DRAWN ON SHEET NUMBER CORP CORRUGATED CJ CONTROL JOINT CT CERAMIC TILE PSI POUNDS PER SQUARE INCH PT PAINT CONTRACTOR OR BY OTHERS. 11 SECTION/DETAIL DESIGNATION • SUPPLY AIR DIFFUSER RETURN AIR 6811E CWCTRL CONTR PVMT PAVEMENT OT QUARRY TILECONSTRUCTED 8. ALL RECESSES LOCATED WITHIN FIRE RATED PARTITIONS SHALL BE TO MAINTAIN REOUIRED FIRE RATING OF THE PARTITION. 9. REFER TO SPECIFICATIONS FOR ACCESS DOORS AND VERIFY WITH 1111 r, DRAWN ON SHEET NUMBER CONTINUOUS EDGE DIFFUSER REFERENCED ON SHEET NUMBER 4 SPRINKLER HEAD INTERIOR ELEVATION DESIGNATION DBL DOUBLE 011 DETAIL DIA DIAMETER DO DITTO DR DOOR DWG DRAWING RONF REINFORCEING ( ) REOD REQUIRED RM ROOM SAN SANITARY SCHED SCHEDULE MECHANICAL AND ELECTRICAL SUBCONTRACTORS EXACT LOCATIONS OF ACCESS REQUIRED BY THEIR WORK. ACCESS MUST BE PROVIDED FOR ALL CONCEALED VALVES, DAMPER CONTROLS, FIRE DAMPER UNKAGES, CONCEALED JUNCTION BOXES, AND ELECTRICAL DEVICES OR ACCESSORIES. LOCATIONS AND SIZES OF EXPOSED ACCESS DOORS SHALL BE SUBMITTED TO THE ARCHITECT FOR SED SD SOAP PSECTIONSP ER REVIEW TO INSTALLATION OF THE MECHANICAL AND FIREEXEXTIN 0151118 CABINET ELEVATION DESIGNATION Arilli EA EACH I SECT 11 EXPANSION JOINT ) SF SQUARE FOOT ELECIRICALOR EQUPMENT. REVIEWED FOR SURFACE MOUNTED {� ---DRAWN ON SHEET NUMBER FIRE EXTINGUISHER CABINET ELEC ELECTRICAL 1 ELEV ELEVATION SLV SHORT LEG VERTICAL 10 EQUAL STD STANDARD 10. IN GENERAL, THE PLAN DIMENSIONS SHOWN ARE AS FOLLOWS: (UNLESS OTHERWISE NOTED.) 0. TO THE FINISHED FACE OF EXISTING INTERIOR WALLS AND CODE COMPLIANCE APPROVED REFERENCED ON S SHEET NUMBER HATCH SYMBOLS L1VC ELECTRIC WATER COOLER STL STEEL EXIST EXISTING THE FACE OF STUD OF NEW INTERIOR WALLS. DIAGRAMATIC ONLY N NORTH ARROW SS SERVICE SINK EXP EXPANSION STM STORM EXP JT EXPANSION JOINT ST STL STAINLESS STEEL EXT EXTERIOR ' SUSP SUSPENDED B. TO THE FINISHED FACE OF EXTERIOR FINISHES. C. TO THE FACE OF CONCRETE AND MASONRY-NOMINAL 11. ALL DOORS NOT LOCATED BY DIMENSION ON PLANS SHALL BE 510 JAN 2 3 2014 MY11149QQQj1j9.Qj BAIT INSULATION FLOOR DRAIN INCHES FROM FACE OF ADJOINING GWB PARTITION TO EDGE OF • IDE ROOM NUMBER F.D. T/ TOP OF F.E. FIRE EXTINGUISHER TEMP TEMPERED DOOR OPENING, OR CENTERED BETWEEN ROOM PARTITIONS. ALL DOORS SEAL HAVE MIMMUM 18' CLEAR ON PULLSIDE. *> <5,<X RIGID INSULATION F &I FURNISH & INSTALL TD PAPER TOWEL DISPENSER City of Tukwila 000000 DOOR NUMBER FIN FINISH TOP/ TOP OF 13. SEE STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS - CONCRETE FIR FLOOR I TYP IYPICA FOR ADDITIONAL NOTES AND SYMBOLS. BUILDING DIVISION FDN FOUNDATION1 FPHB FROST PROOF HOSE-RIB 14. ALL CONTRACTOR INSTALLED ITEMS SHALL BE SUPPLIED WITH REOUIRED (r-x') CEILING HOGHT X/VX/VX MASONRY FRT FIRE RETARDANT TREATED LINO UNLESS NOTED OTHERWISEMECHANICAL UR URINAL AND ELECTRICAL SERVICES TO PROVIDE PROPER OPERATION OF FTG FOOTING I ITEMS INSTALLED. PROVIDE REQUIRED MECHANICAL AND ELECTRICAL FOR BY OTHERS. t . , - : GYPSUM BOARD 1.1. _, ... :., .. I VCT ARYL COMPOSITION TILE SERVICES ITEMS INSTALLED WALL TYPE A GA GAUGE VERT VERTICAL 15. AT METAL STUD PARTITIONS, STUDS ARE TO EXTEND FROM CONCRETE FLOOR SLAB SEW 5C.RF,Dp GRAVEL 7� 7�- Jo� GAV GALVANIZED I WNC VINYL WALL COVERING GC GENERAL CONTRACTOR TO UNDERSIDE OF THE STRUCTURE ABOVE, UNLESS OTHERWISE NOTED. GL GLASS WD WOTER CLOSET WHERE THEY CANNOT DO SO, DUE TO INTERFERENCE WITH NEW OR O EQUIPMENT TYPE �r'��Ei%%aiun�uiriiu.:au' FlRESTOPPINC NB GYPSUM WALL BOARD WD WOOD EXISTING DUCTS, PIPING, ETC., PROVIDE BRACING TO STRUCTURE WH WATER HEATER ABOVE TO PROVIDE FOR [OUP/ALERT SUPPORT OF PARTITION; SUBMIT SOUND ''44.i.' _4 EARTH H HIGH WWF WELDED WIRE FABRIC EQUIVALENT SUPPORT METHOD TO BOEING CIA FOR REVIEW. ALL FIRE AND 10270 RAISED ACCESS FLOOR HC HANDICAPPED WPW WINppW RATED DAIMONS SHALL. BE CONSTRUCTED TO MAINTAIN THEIR RATING FROM CONCRETE FLOOR SLAB TO UNDERSIDE OF STRUCTURE ABOVE, U.N.O. (PLAN DESIGNATION) 1M HOLLOW METAL W/ WITH RECEIVED HORIZ HORIZONTAL I HP HIGH 16. PROVIDE BACKING FOR ALL WALL MOUNTED ITEMS. HVAC HEATING,NT VENTILATING,• AIR CONDITIONING 17. FOR HANGING TOILET PARTITIONS, EXTEND SUPPORT TO STRUCTURE ABOVE CITY OF T U K W I L A HW HOT WATER MATCH EXISTING CONFIGURATION. INSUL lNSULAT(ION)(ED) DEC 0 5 2013 INT INTERIOR 11 JOINT PERMIT CENTER ......................................... 09520 ACOUSTICAL WALL PANEL (ELEVATION DESIGNATION) rolluda architects 105 S. Main Street Suite 323 Seattle, WA 98104 L 206-6244222 f-. 206-624-4226 FOR REFERENCE ONLY 95% DESIGN REVIEW FACILITY DESIGN BY ROILUDA ARCH DATE 1003.13 JDB3773: 11/29/2010 9:10:! SYM REVISION of APPROVED DUE VIA REV60N BY APPROVED DAD. ACCEPTABILITY DRAWN ARCH D10.03.13 SUIS SYMBOLS, ABBREVIATIONS & GENERAL NOTES IUNAD4T HEVISIDN W1696197 rneoE A DATE 10.03.13 - KITCHENETTE UPGRADES CMT-S-12107 AF AJC 08.21.12 I T OLS DESIGN MID/OR SPECIFICATION I5 APPROVED CHECKED SHEET A RESTROOM REMODEL 141777333 RAVAF 07.09.13•APPRO'+ID BY DEPT. DATE mvl"�R TR`E MAJOR PASSENGER ELEVATOR REPAIR G1 a B MAJOR PASSENGER ELEVATOR REPAIR 147696197 RM/AF 10.03.13rel_ATISFAEFAKG CHECKED APPROVED BUILDING 11-14N JOB NO. W1696197 COMP N0. I APPROVEDDWG ARCHITECTURAL MASTER COL. N/A DUWAMISH, WA N0. 11-14N-G1 10 U l CD- 6 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila t BUILDING DIVISION 0 GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO START OF CONSTRUCTION. IF ANY DISCREPANCIES ARE FOUND, NOTIFY THE ARCHITECT. ANY PROPOSED CHANGES SHALL HAVE PRIOR APPROVAL FROM THE ARCHITECT. 2. ALL WORK TO COMPLY WITH REGULATIONS IN EFFECT IN WASHINGTON AND WASHINGT RI ES AND CONSTRUCTION NOTES: REMOVE EXISTING LOUVER. INFILL WALL AND FINISH AS INDICATED. INFILL AT EXISTING LOUVER RECEIVED CITY OF TUKWILA JAN 1 3 2014 PERMIT CENTER ISSUED FOR CONSTRUCTION PA11 PA10 KEY PLAN SCALE: 0 rolluda architects 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 t 206-624-4226 REV6DN BY APPROVED m BY APPRE ED DATE ORIG DRAWING MAJOR PASSENGER ELEVATOR REPMR PERMIT COMMENT REVISION W1696197 RN/AF 11.08.13 01.10.14 g)Lteinsr,Argy° ACCEPTABILITY THIS DESIGN MID/OR SPECIFICATION 5 APPROVED APPROOED BY OEPT. DATE TRAIN ROLLUDA ARCH IA. KW 2ATE 11.08.13 SUBRRE PARTIAL PENTHOUSE FLOOR PLAN CURRENT REVISION W1696197 SYMBOL A DATE 11.08.13 ENGINEER NECKED APPRDVED NILE ' . MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14N COL G -M/6-12 ARCHITECTURAL MASTER DUWAMISH, WA SHEET PA11 ,JOB NO. W1696197 COMP NO. DPG NO. 11-14N-PA11 JD113773: 4/7/2011 7:22:33 MA 12 11 10 U U U CO GENERAL NOTES: 1 1. CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO START OF CONSTRUCTION. IF ANY DISCREPANCIES ARE FOUND, NOTIFY THE ARCHITECT. ANY CLJJ PROPOSED CHANGES SHALL HAVE PRIOR APPROVAL FROM THE ARCHITECT. 2. ALL WORK TO COMPLY WITH COIES,AND REGULATIONS IN EFFECT IN WASHINGTON AND WASHINGT4' \ II._- CONSTRUCTION NOTES: .�-- ' ■.• REVIE D FOR AND STRUCTURALASFOR SEE MECHANICAL EQUIPMENT MECHANICAL EQUIPMENT AND BASE INFORMATION. CODE CO PL 11G ... . APPR �lED ---- �,--�- -, 01. /01* JAN 3 20140,0010 . • , Ci of LDING Tukwila T IVI SIGN O:4.4t,*iIiIi, moi8•RFA11, RFAtOI j WWI,/• RECEIVED CITY OF TUKWILA KEY PLAN N SCALE: NONE JAN 1 3 2014 PERMIT CENTER ROOF PLAN ��j�\� rolluda architects (G SCALE: 1/8" = 1'-0" 105 S. Main Street Suite 323 O/ Seattle, WA 98104 - !ISSUED FOR CONSTRUCTION t: 206-624-4222 t: 206-624-4226 JD83773: 4/22/2011 7:34:28 VIA REVISION BY APPROVED DAD SW REVISION BY raPTDCD DAff I ACCEPTABILITY DRAWN ROLLUOA ARCH DATE 11.08.13 SUDmu ROOF CURRENT REVISION W1696197 SYMBOL DME 11.08.13 A AS—BUILT BY WOOD/HARBINGER NS DESIGN MID/OR t:Rfr:Rm PLAN MWS 12.31.92 1 SPECIFICATION 5 APPROVED SHEET 8 MAJOR PASSENGER ELEVATOR REPMR W1696197 RAI/AF 11.08.13 APPROVEDaroEvr,SAECHECKED fLATONLEN TIT`E MAJOR PASSENGER ELEVATOR REPAIR RFA11 Q PERMIT COMMENT REVISION 01.10.14 gifirWAKM. APPROVED BUILDING 11-14N JOB NO. W1696197P APPROVED ARCHITECTURAL MASTER COL. G -M/6-12 DUWAMISH, WA DWG ND. 11-14S-RFA11 VI CAULKING AT INFILL AND PIPING, TYP. W3 TYPE "X" GWB OVER VAPOR BARRIER OVER LT. GAGE METAL STUDS ® 16"0.C. WITH FULLY BATT INSULATION CAVITY CAULKING AT INFILL AND PIPING, TYP. ANNAAKKATKAiNAMANMe iNATINNAONMANN802W026 INTERIOR EN; • EXTERIOR LOUVER INFILL DETAIL SCALE: 3/4" = 1'-0" REMOVE INTERIOR DAMPER, GRILLE AND MECHANISM STUDS WITH R-19 BATT INSULATION OVER 1" RIGID INSULATION OVER 22 GA. PREFINISHED CONTINUOUS CLOSURE PANEL AT INSIDE OF EXTERIOR GRILLE. FASTEN AT 4" 0.C. AT EDGE AND 12" 0.C. IN FIELD WITH STAINLESS STEEL PAN HEAD SCREWS CONTINUOUS S.S. DRIP EDGE 1" RIGID INSULATION SHEET METAL SIDING PANEL, COLOR TO MATCH BUILDING, OVER 1" RIGID INSULATION. FASTEN SHEET METAL THRU INSULATION TO STUDS WITH FASTENER WITH NEOPRENE WASHERS PIPING AT PENETRATION PER MECHANICAL. PROVIDE CLOSURE PER SMACNA FIG 4-15A EXTERIOR GRADE GYPSUM SHEATHING BACKER ROD & SEALANT, TYP. WELDED SILL PAN EXISTING EXTERIOR WALL fl 5/8" TYPE X FIRE TAPED GWB OVER 3 1/2" 20 GA. METAL INTERIOR RFA11, PA1�510 EXISTING EXTERIOR GRILLE AND FRAMING TO REMAIN EXTERIOR PROVIDE SEALANT AT LOWEST GRILLE FIN AND SIDES OF GRILLE AT SHEET METAL PANEL EXISTING WALL AND FRAMING TO REMAIN LOUVER INFILL DETAIL SCALE: 3/4" = 1'-0" RFA11, PA111A510 EQUIPMENT SUPPORT - SEE STRUCTURAL DRAWINGS PROVIDE FLASHING & STAINLESS STEEL CLAMP PER ROOFING MANUFACTURER RECOMMENDATIONS PATCH ROOFING TO MATCH EXISTING REPLACE INSULATION TO MATCH EXISTING ROOF, PENETRATION DETAIL SCALE: 1 1/2" = 1'-0" CAULKING AT INFILL AND PIPING, TYP. 2 RFA11, PA1j510 Wa TYPE "X" GWB OVER VAPOR BARRIER OVER LT. GAGE METAL STUDS ® 16"0.C. WITH FULLY BATT INSULATION CAVITY INTERIOR PROVIDE S.S. DRIP EDGE AT HEAD OVER SELF ADHERING MEMBRANE pit VIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION SHEET METAL SIDING PANEL, COLOR TO MATCH BUILDING, OVER 1" RIGID INSULATION. FASTEN SHEET METAL THRU INSULATION TO STUDS WITH FASTENER WITH NEOPRENE WASHERS PROVIDE CONT. FLASHING AT DUCT PENETRATION WITH CONT. SEALANT / NEW DUCT WORK WITH INSULATION // PER MECHANICAL EXTERIOR LOUVER INFILL DETAIL @ HEAD( SCALE: 1 1/2" = 1'-0" �A510 NEW DUCT WORK PER MECHANICAL INTERIOR NEW DUCT WORK PER MECHANICAL -EXISTING EXTERIOR WALL EXTERIOR LOUVER INFILL DETAIL SCALE: 3/4" = 1'-0" RFA11, PA1,510 PROVIDE CONT. FLASHING AT DUCT PENETRATION WITH CONT. SEALANT NEW DUCT WORK WITH INSULATION PER MECHANICAL TYPE "X" GWB OVER VAPOR BARRIER OVER LT. GAGE METAL STUDS 0 16"0.C. WITH FULLY BATT INSULATION CAVITY CAULKING AT INFILL AND PIPING, TYP. INTERIOR s/ SHEET METAL SIDING PANEL, COLOR TO MATCH BUILDING, OVER 1" RIGID INSULATION. FASTEN SHEET METAL THRU INSULATION TO STUDS WITH FASTENER WITH NEOPRENE WASHERS 20 GA. S.S. FULLY SOLDER CONT. SILL PAN BACKER ROD & SEALANT, TYP. EXISTING EXTERIOR WALL AND INSULATION TO REMAIN EXTERIOR LOUVER INFILL DETAIL @ SILL SCALE: 1 1/2" = -A510 RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 95% DESIGN REVIEW 0 6" 1' 2' 3' 4' SCALE: 1 1/2" = 1'-0" rolluda architects 105 S. Main Street Suite 323 Seattle, WA 98104 t 206-624-4222 f: 206-624-4226 SYM REVISION OA sr DA - MAJOR PASSENGER ELEVATOR REPAIR W1696197 AF 10.03.13 el. r45 f#SW' ACCEPTABILITY TH15 DESIGN AND/OR SPECIFICATION IS APPROVED NLLN APPROVED BY DEPT. DATE CHECKED DRAWN ROAD ARCH DATE 10.03.13 SUBTITLE DETAILS & WALL TYPES CURRENT RD 1S O W1696197 SYMBOL DATE 10.03.13 APPROVED APPROVED MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14N COL. N/A ARCHITECTURAL MASTER DUWAMISH, WA SHEET A510 JOB O. W1696197 COMP NO. D 0. 11 -14N -A510 3: U/24/2010 12:27:57 PM CAULKING AT INFILL AND PIPING, TYP. PitiVict TYPE "X" GWB OVER VAPOR BARRIER OVER LT. GAGE METAL STUDS 16"0.C. WITH FULLY BATT INSULATION CAVITY CAULKING AT INFILL AND PIPING, TYP. INTERIOR M"" EXTERIOR LOUVER INFILL DETAIL SCALE: 3/4" = 1'-0" REMOVE INTERIOR DAMPER, GRILLE AND MECHANISM CONTINUOUS S.S. DRIP EDGE 1" RIGID INSULATION SHEET METAL SIDING PANEL, COLOR TO MATCH BUILDING, OVER 1" RIGID INSULATION. FASTEN SHEET METAL THRU INSULATION TO STUDS WITH FASTENER WITH NEOPRENE WASHERS PIPING AT PENETRATION PER MECHANICAL. PROVIDE CLOSURE PER SMACNA FIG 4-15A EXTERIOR GRADE GYPSUM SHEATHING BACKER ROD & SEALANT, TYP. WELDED SILL PAN EXISTING EXTERIOR WALL 5/8" TYPE X FIRE TAPED GWB OVER 3 1/2" 20 GA. METAL STUDS WITH R-19 BATT INSULATION OVER 1" RIGID INSULATION OVER 22 GA. PREFINISHED CONTINUOUS CLOSURE PANEL AT INSIDE OF EXTERIOR GRILLE. FASTEN AT 4" 0.C. AT EDGE AND 12" 0.C. IN HELD WITH STAINLESS STEEL PAN HEAD SCREWS INTERIOR 010 ti411110-.0-401.10 RFA10, PA101A501 EXISTING EXTERIOR GRILLE AND FRAMING TO REMAIN EXTERIOR PROVIDE SEALANT AT LOWEST GRILLE FIN AND SIDES OF GRILLE AT SHEET METAL PANEL EXISTING WALL AND FRAMING TO REMAIN LOUVER INFILL DETAIL SCALE: 3/4" = 1'-0" RFA10, PA101501 EQUIPMENT SUPPORT — SEE STRUCTURAL DRAWINGS PROVIDE FLASHING & STAINLESS STEEL CLAMP PER ROOFING MANUFACTURER RECOMMENDATIONS PATCH ROOFING TO MATCH EXISTING REPLACE INSULATION TO ./ MATCH EXISTING implanr ROOF PENETRATION DETAIL 2 SCALE 1 1/2" = 1'-0" CAULKING AT INFILL AND PIPING, TYP. Y6 TYPE "X" GWB OVER VAPOR BARRIER OVER LT. GAGE METAL STUDS ® 16"0.C. WITH FULLY BATT INSULATION CAVITY RFA10, PA101A501 PROVIDE S.S. DRIP EDGE AT HEAD OVER SELF ADHERING MEMBRANE REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION SHEET METAL SIDING PANEL, COLOR TO MATCH BUILDING, OVER 1" RIGID INSULATION. FASTEN SHEET METAL THRU INSULATION TO STUDS WITH FASTENER WITH NEOPRENE WASHERS PROVIDE CONT. FLASHING AT DUCT PENETRATION WITH CONT. SEALANT NEW DUCT WORK WITH INSULATION PER MECHANICAL INTERIOR EXTERIOR 1. LOUVER INFILL DETAIL @ HEAD( SCALE: 1 1/2" = i'-0" `1,501 NEW DUCT WORK PER MECHANICAL INTERIOR NEW DUCT WORK PER MECHANICAL — EXISTING EXTERIOR WALL EXTERIOR LOUVEP INFILL DETAIL SCALE: 3/4" = 1'-0" ZD RFA10, PA1 j, 501 PROVIDE CONT. FLASHING AT DUCT PENETRATION WITH CONT. SEALANT NEW DUCT WORK WITH INSULATION PER MECHANICAL ;6 TYPE "X" GWB OVER VAPOR BARRIER OVER LT. GAGE METAL STUDS 0 16"0.C. WITH FULLY BATT INSULATION CAVITY CAULKING AT INFILL AND PIPING, TYP. 0 6" 1' INTERIOR SHEET METAL SIDING PANEL, COLOR TO MATCH BUILDING, OVER 1" RIGID INSULATION. FASTEN SHEET METAL THRU INSULATION TO STUDS WITH FASTENER WITH NEOPRENE WASHERS 20 GA. S.S. FULLY SOLDER CONT. SILL PAN BACKER ROD & SEALANT, TYP. EXISTING EXTERIOR WALL AND INSULATION TO REMAIN EXTERIOR LOUVER INFILL DETAIL @ SILL SCALE: 1 1/2" = 1'-0" 2' 3' 4' SCALE: 1 1/2" = 1'-0" RECEIVED CITY OF TUKWILA `1,501 DEC 0 5 2013 PERMIT CENTER rolluda architects 95% DESIGN REVIEW 105 S. Main Street Suite 323 Seattle, WA 98104 t 206-624-4222 f: 206-624-4226 Sri or DATE DA MAJOR PASSENGER ELEVATOR REPAIR W1696197 AF 10.03.13 ACCEPTABILITY MS DESIGN AND/OR SPECIFICATION 5 APPROVED APPROVED BY DEPT. DATE DAAWN ROLLUDA ARCH LRECRED TSR 10.03.13 DETAILS & WALL TYPES CURRENT REVISION W1696197 SYMBOL DATE 10.03.13 �lNT,Wttk CHECKED APPROVED APPROVED MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14S COL. N/A ARCHITECTURAL MASTER DUWAMISH, WA SHEET A501 JOB N0. W1696197 COMP NO DWG NO. 11 -14S -A501 (C) (D (E) (F) MATCHUNE SEE SHEET RFM11 sYM A B REVISION AS -BUILT BY WOOD/HARBINGER MAJOR PASSENGER ELEVATOR REPAIR W1696197 BY MWS RAI/AF APPROVED DALE SYM BY APPROVED DATE 12.31.92 11.08.13 0" PERMIT COMMENT REVISION 01.10.14 g)LAFAFEFAW ACCEPTABILITY THIS DESIGN MID/OR SPECIFICATION IS APPROVED DRAWN ROLLUDA ARCH 0 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION GENERAL NOTES: 1. CONTRACTOR SHALL VERIFY ALL EXISTING CONDI11ONS AND DIMENSIONS PRIOR TO START OF CONSTRUCTION. IF ANY DISCREPANCIES ARE FOUND, NOTIFY THE ARCHITECT. ANY PROPOSED CHANGES SHALL HAVE PRIOR APPROVAL FROM THE ARCHITECT. 2. ALL WORK TO COMPLY WIT REGULATIONS IN EFFECT I WASHINGTON AND WASHING CONSTRUCTION NOTES: S. AND REMOVE EXISTING LOUVER. INFILL WALL AND FINISH AS INDICATED. INFILL AT EXISTING LOUVER. RECEIVED CITY OF TUKWILA JAN 1 3 2014 PERMIT CENTER FLOOR PLAN C) SCALE: 1/8' = DATE 11.08.13 SUBRRE (ISSUED FOR CONSTRUCTION] PARTIAL PENTHOUSE FLOOR PLAN KEY PLAN SCALE: NONE rolluda architects 105 S. Main Street Suite 323 Seattle, WA 98104 t 206-624-4222 t 206-624-4226 CURRENT REVISION W1696197 SYMBOL B DATE 11.08.13 APPROVED BY DEPT. DATE LNGINEER CHECKED APPROVED APPROVED TITLE MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14S ARCHITECTURAL MASTER COL. 1-7/A—G SHEET PA10 JON NO. W1696197 COMP NO. DUWAMISH, WA DWG NO. 11-14S—PA10 D03773: 4/22/2011 (J (C (D (J L MATCHUNE SEE SHEET RRA11 O ROOF PLAN SCALE: 1/8" = 1'-0" N REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION REY5ON DATE SYN DATE AS -BUILT EAT W000/HARBINGER MWS 12.31.92 MAJOR PASSENGER ELEVATOR REPAIR W1696197 RAI/AF 11.08.13 PERMIT COMMENT REVISION 01.10.14 g)LASFAFEFAW ACCEPTABILITY MS DESIGN AND/OR SPECIFICATION 5 APPROVED ROLLUDA ARCH MELT 11.08.13 SUBTITLE 0 RECEIVED CITY OF TUKWILA JAN 1 3 2014 PERMIT CENTER 'ISSUED FOR CONSTRUCTION ROOF PLAN GENERAL NOTES: CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO START OF CONSTRUCTION. IF ANY DISCREPANCIES ARE FOUND, NOTIFY THE ARCHITECT. ANY PROPOSED CHANGES SHALL HAVE PRIOR APPROVAL FROM THE ARCHITECT. 2. ALL WORK TO COMPLY WITH REGULATIONS IN EFFECT IN WASHINGTON AND WASHINGT C4� S,AND CONSTRUCTION NOTES: SEE MECHANICAL AND STRUCTURAL SHEETS FOR MECHANICAL EQUIPMENT AND BASE INFORMATION. KEY PLAN SCALE: NONE N rolluda architects 105 S. Main Street Suite 323 Seattle, WA 98104 t: 206-624-4222 f: 206-624-4226 CURRENT REVISKIN W1696197 SYMBOL DATE 11.08.13 APPROVED BY DEPT. DATE IN CNLCKED PPRCVED APPROVED MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14S ARCHITECTURAL MASTER COL. 1 -7/A -G DUWAMISH, WA MEET RFA10 JOB W1696197 COMP NO. DWG NO. 11-14S-RFA10 2/2011 7:34:28 MI (L) (Ki O 0 (D (C) //// /1/ / ll; 1/ REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2.014 City of Tulosila BUILDING DIVISION /% 0 0 (7) LEGEND (6) GENERAL NOTES (5) REFERENCE DRAWINGS (4) ROOF LEVEL PARTIAL PLAN SCALE: 1/16"=1'0" REVISION Err DATE BY DATE MAJOR PASSENGER ELEVATOR REPAIR W1696197 PCS 10.03.13 � BOE/HG' 6� ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED - DRscom 000 DGC CHECKED DATE 10 03 13 suBTTn.E (3) CONSTRUCTION NOTES PROVIDE NEW STEEL FRAME FOR NEW AIR CONDITIONER. WEIGHT = 85011 PRIME AND PAINT PER ARCH AND SPECIFICATIONS; GALVANIZED FINISH NOT ALLOWED ON ANY EXPOSED EXTERIOR STEEL. VERIFY POST TENSION TENDON LOCATION PRIOR TO DRILLING HOLES FOR ANCHORAGE OF STEEL FRAME. RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 195% DESIGN REVIEW PARTIAL ROOF PLAN - SOUTH OPCS Structural Solutions 811 Pint Amin, Suite 820 Seattle, Washington 98104 tot 2982925078 1250 Pacific Avenue, Smite 701 11oome, Washington 98W2 tat 253.3892797 CURRENT REVISION W1696197 SYMBOL DATE 10.03.13 APPROVED BY DEPT. DATE RM0 CHECkED 10 03 13 APPROVED APPROVED 11-14 MAJOR PASSENGER ELEVATOR REPAIR STRUCTURAL MASTER BUILDING 11-14S COL. A—G/1-12 DUWAMISH SHEET S160 JOB NO COMP NO. DWG NO. 11-14S—S160 {{� REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2.014 City of Tulosila BUILDING DIVISION /% 0 0 (7) LEGEND (6) GENERAL NOTES (5) REFERENCE DRAWINGS (4) ROOF LEVEL PARTIAL PLAN SCALE: 1/16"=1'0" REVISION Err DATE BY DATE MAJOR PASSENGER ELEVATOR REPAIR W1696197 PCS 10.03.13 � BOE/HG' 6� ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED - DRscom 000 DGC CHECKED DATE 10 03 13 suBTTn.E (3) CONSTRUCTION NOTES PROVIDE NEW STEEL FRAME FOR NEW AIR CONDITIONER. WEIGHT = 85011 PRIME AND PAINT PER ARCH AND SPECIFICATIONS; GALVANIZED FINISH NOT ALLOWED ON ANY EXPOSED EXTERIOR STEEL. VERIFY POST TENSION TENDON LOCATION PRIOR TO DRILLING HOLES FOR ANCHORAGE OF STEEL FRAME. RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 195% DESIGN REVIEW PARTIAL ROOF PLAN - SOUTH OPCS Structural Solutions 811 Pint Amin, Suite 820 Seattle, Washington 98104 tot 2982925078 1250 Pacific Avenue, Smite 701 11oome, Washington 98W2 tat 253.3892797 CURRENT REVISION W1696197 SYMBOL DATE 10.03.13 APPROVED BY DEPT. DATE RM0 CHECkED 10 03 13 APPROVED APPROVED 11-14 MAJOR PASSENGER ELEVATOR REPAIR STRUCTURAL MASTER BUILDING 11-14S COL. A—G/1-12 DUWAMISH SHEET S160 JOB NO COMP NO. DWG NO. 11-14S—S160 (A) (B) (C (12 11 Co) (9J Q) 0 6 r_ (D) (E) \\\ 1 F[1 A REVIEWED F CODE COMPL J o R NCE APPROVE JAN 2 3 201 City of Tukwil BUILDING DTVI ION ROOF LEVEL PARTIAL PLAN SCALE: 1/16"=1'0" SYM ROBSON BY APPROVED DATE SYM BR ON EN APPRDVED DATE A MAJOR PASSENGER ELEVATOR REPAIR W1696197 PCS 10.03.13 ,�Bli OE/A' v� ACCEPTABILITY 106 DESIGN AND/OR SPECIFICATION 6 APPROVED APPROVED BY DEPT. DATE DRAWN DGC CHECKED TE 10.03.13 LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE NEW STEEL FRAME FOR NEW AIR CONDITIONER. WEIGHT = 85011. PRIME AND PAINT PER ARCH AND SPECIFICATIONS; GALVANIZED FINISH NOT ALLOWED ON ANY EXPOSED EXTERIOR STEEL. VERIFY POST TENSION TENDON LOCATION PRIOR TO DRILLING HOLES FOR ANCHORAGE OF STEEL FRAME. RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 195% DESIGN REVIEW SUBTIRE PARTIAL ROOF PLAN - NORTH 41PCS Structural Solutions 811 Plast Avenue, Suits 820 Seattle. Washington 98104 tt 2082925078 1250 PrditMenne, Suite 701 Mauna, Washington 98402 tet 2539892797 CURRENT REVSK)N W1696197 SYMBOL A DATE 10.03.13 2NSINLU CHECKED APPROVED APPROVED TITLE 11-14 MAJOR PASSENGER ELEVATOR REPAIR STRUCTURAL MASTER BUILDING 11-14N SHEET S160 JOB N0. COMP N0. COL A—G/6-12 DUWAMISH, WA DWG No. 11-14N-5160 VARIES T TENDON FIELD - 16' MAX uJ a (VERIFY W/ MFR ) SUIT PT _OCATION IN MIN - - TYP may / WT6x15 L5x3x3/B (LLV) I WT6x15 /414- S504 5504 PLAN DETAIL SCALE: 1/2"=1'-0" 3' DIA STD PIPE MECH UNIT ATTACH TO FRAME PER MFR'S RECOMMENDATIONS ADJUST LOCATION OF BASE PLATE/ANCHORAGE TO AVOID PT TENDONS BY 6' MIN C.P S504 3/16 3/4' PLATE x9'x0'-9' W/ (4) 3/4' DIA THR'D RODS (ASTM 636) - DRILL ,- 1 1/2" TYP. & EPDXY EMBED 5' MIN / 6 MAX INTO EXIST CONC SLAB WITH HILTI HIT -4150 -SD OR APPROVED EQUAL• PROVIDE SEAL BETWEEN PIPE &WT SECTION SCALE: 1".1.-0" -1 EXIST 8-1/2' CONC PT SLAB NQg: VERIFY SLAB REINF LOCATION PRIOR TO INSTAWNG ANCHORS REM SKIN A MAJOR PASSENGER ELEVATOR REPAIR W1696197 BY PCS APPROVED DATE SYM BY APPROVED DATE 10.03.13 QLBOE/NQ' ACCEPTABILITY THIS DESIGN MND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN DGC CHL LD S504 LEGEND GENERAL NOTES 1. PT = POST TENSIONED 2. CP = COMPLETE PENETRATION 3. WEIGHT OF UNIT ON PLATFORM = 850# REFERENCE DRAWINGS CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA DEC $ 5 2013 PERMIT CENTER L95°io DESIGN REVIEW I 41 PCS Structural Solutions 811 Post Avenue, Sake 820 Seattle, Washington 98104 tot 2082925078 1250 Pacific Avenue, Suite 701 Tacoma, Washington 98402 Mt 253.383.2797 DATE 10.03.13 SUBTITLE DETAILS AND SECTIONS CURRENT REVISION 1696197 SYMBOL DATE 10.03.13 NAINLLN CHECKED APPROVED APPROVED TOTE 11-14 MAJOR PASSANGER ELEVATOR REPAIR BUILDING 11-14N/S STRUCTURAL MASTER COL. A -G/1-12 SHEET S504 JOB NO. COMP NO. DUWAMISH, WA owD No. 11-14-5504 THOMASL 04/05/10 15:33 14> 15> 14> I2> L4>13> COMPUTER ROOM AIR CONDITIONER SCHEDULE - UNITS ON STANDBY POWER UNLESS NOTED MARK LOCATION RATINGS SERVICE POWER MANUFACTURER AND MODEL NOTES CFM SENSIBLE COOLING TOTAL COOUNG RET. AIR LDB/LWB REJECTION FLOW CONDITIONS FAN+COMPRESS REHEAT+HUM VOLTS AMPS VOLTS AMPS VOLTS AMPS VOLTS AMPS AC -1S 1 SOUTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT -1S 272 GPM 1 460/3 CAC -1S -D4.5 1 SOUTH DATA CLOSET -11D4 DATA ROOM BACK UP AIR CONDTIONER 1800 CFM 3 4 HP)72F/GPM / 33.1 MBTUH 38.3 MBTUH RA AT 50%RH CT -1S 3.8 85.0/95.0 460 VAC 3 PH 1.4 RLA 460 VAC 3 PH 19.6 FLA WITH ,ELECTRIC REHEAT & INFRARED HUMIDIFIER, NON-FUSED DISCONNECT SWITCH, COMPRESSOR CRANKCASE HEATER AND HIGH HEAD OPTION WRH ADVANCED MICROPROCESSOR CONTROL WITH GRAPHICS, CONDENSATE PUMP, SEISMIC RATED 18' HIGH FLOOR STAND, SMOKE DETECTOR, AND MODBUS INTERFACE CARD 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH VVX-952-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-06-01 R-22, 86 LBS, CIR 1, 73 LBS CIR 2 AC -3S 3 SOUTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1S 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH VVX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-01-01 R-22, 71 LBS, PR 1, 57 IBS CIR 2 AC -4S 4 SOUTH. MECH RM. OFFICE A/C 30000 838 MBTUH 918 MBTUH. 55.1/52.5 CT -1S 236 GPM. _ 85.0/95.0 460/3_ 54.0_ _460/3 .52.3x2 _MAMMOTH-VVX-802=GXL GEN_. NOTE_ 6_ FOR COMPRESSORS S/N. 21384-02-01 R-22, 71 LBS, CIR 1, 57 LBS Chi 2 AC -5S 5 SOUTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1S 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH VVX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-02-02 R-22, 71 LBS, CIR 1, 57 LBS CIR 2 I AC -1N 1 NORTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT -1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX-952-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-03-01 R-22, 86 LBS, CIR 1, 73 LBS CIR 2 I AC -2N 2 NORTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT -1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX-952-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-05-01 R-22, 86 LES, PR 1, 73 LBS CIR 2 AC -3N 3 NORTH MECH RM c 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-06-01 R-22, 71 LEIS, CIR 1, 57 LBS CIR 2 AC -4N 4 NORTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-01-02 R-22, 71 LBS, CIR 1, 57 LDS CR 2 AC -5N 5 NORTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH VVX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-01-03 R-22, 71 LEG, CIR 1, 57 1B6 CIR 2 AC -6N 1 CAFE MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT -1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21736-01-01 R-22, 78 LBS, CIR 1, 65 LBS CIR 2 1 AC -6S 4TH FLR ROOM 43.14 I 990 _ 30 MBTUH --- AC -6S --- 75.0/95.0 115/1 2.0 206/230/1 20 MITSUBISHI PK3OFK1 INDOOR UNIT MITSUBISHI PU3OEK OUTDOOR UNIT { AC -1N -F10 1ST FLR ROOM 11F9 VIDEO SERVER ROOM 1320 26.4 MBTUH 32.1 MBTUH 72F-50RH AC -ON -M16 --- 72.0/95.0 206/230/1 2.2 460/3 6.4 LIEBERT DATAMATE LIEBERT DATAMATE PFH037A-AL3 DME037E-PC3 INDOOR UNIT OUTDOOR UNIT HP -1 GARAGE LEVEL BATTERY ROOM 300 11.3 10.7 MBTUH 53.7/51.3 AIR TO AIR -- -- -- -- -- -- CARRIER MODEL UPS ROOM MBTUH HEATING 52SQA312---3 REVIEWED FOR )DE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila ILDING DIVISION LEGEND GENERAL NOTES 1) PUMPS AND DIFFUSER SCHEDULES TRANSFERRED TO SHEET M2g 1 2 > UNIT REMOVED FROM SERVICE 1 3 > SEE SHEETS 11 -14L -1M10 AND 11-140-0M12 FOR LOCATIONS OF THESE UNITS 1 4 > UNIT ON STANDBY POWER DURING UTILITY OUTAGES - REFERENCE JOBS 150687-01 AND 150686-00 5 > UNIT ON NORMAL UTILITY POWER - UNIT WILL NOT RUN DURING OUTAGES 6) COPELAND MODEL 6DS1-4000-TSN 40 HP REGULAR SUMP COMPRESSORS AIR CONDITIONER AND HEAT PUMP SCHEDULE MARK LOCATION SERVICE RATINGS POWER I MANUFACTURER I AND MODEL NOTES ADDITIONAL INFORMATION REFRIGERANT AND QTY CFM SENSIBLE COOUNG TOTAL COOLING NET LDB/LWB REJECTION FLOW CONDITIONS FAN COMPRESSOR VOLTS AMPS VOLTS AMPS AC -1S 1 SOUTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT -1S 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH VVX-952-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-03-01 R-22, 86 LBS, CIR 1. 73 LBS CIR 2 AC -2S 2 SOUTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT -1S 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH VVX-952-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-06-01 R-22, 86 LBS, CIR 1, 73 LBS CIR 2 AC -3S 3 SOUTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1S 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH VVX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-01-01 R-22, 71 LBS, PR 1, 57 IBS CIR 2 AC -4S 4 SOUTH. MECH RM. OFFICE A/C 30000 838 MBTUH 918 MBTUH. 55.1/52.5 CT -1S 236 GPM. _ 85.0/95.0 460/3_ 54.0_ _460/3 .52.3x2 _MAMMOTH-VVX-802=GXL GEN_. NOTE_ 6_ FOR COMPRESSORS S/N. 21384-02-01 R-22, 71 LBS, CIR 1, 57 LBS Chi 2 AC -5S 5 SOUTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1S 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH VVX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-02-02 R-22, 71 LBS, CIR 1, 57 LBS CIR 2 I AC -1N 1 NORTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT -1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX-952-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-03-01 R-22, 86 LBS, CIR 1, 73 LBS CIR 2 I AC -2N 2 NORTH MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT -1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX-952-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-05-01 R-22, 86 LES, PR 1, 73 LBS CIR 2 AC -3N 3 NORTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-06-01 R-22, 71 LEIS, CIR 1, 57 LBS CIR 2 AC -4N 4 NORTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH WX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-01-02 R-22, 71 LBS, CIR 1, 57 LDS CR 2 AC -5N 5 NORTH MECH RM OFFICE A/C 30000 838 MBTUH 918 MBTUH 55.1/52.5 CT -1N 236 GPM 85.0/95.0 460/3 54.0 460/3 52.3x2 MAMMOTH VVX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21384-01-03 R-22, 71 LEG, CIR 1, 57 1B6 CIR 2 AC -6N 1 CAFE MECH RM OFFICE A/C 32000 929 MBTUH 1075 MBTUH 53.7/51.3 CT -1N 272 GPM 85.0/95.0 460/3 54.0 460/3 60.5x2 MAMMOTH WX-802-GXL GEN NOTE 6 FOR COMPRESSORS S/N 21736-01-01 R-22, 78 LBS, CIR 1, 65 LBS CIR 2 1 AC -6S 4TH FLR ROOM 43.14 COMP LAB AC 990 --- 30 MBTUH --- AC -6S --- 75.0/95.0 115/1 2.0 206/230/1 20 MITSUBISHI PK3OFK1 INDOOR UNIT MITSUBISHI PU3OEK OUTDOOR UNIT { AC -1N -F10 1ST FLR ROOM 11F9 VIDEO SERVER ROOM 1320 26.4 MBTUH 32.1 MBTUH 72F-50RH AC -ON -M16 --- 72.0/95.0 206/230/1 2.2 460/3 6.4 LIEBERT DATAMATE LIEBERT DATAMATE PFH037A-AL3 DME037E-PC3 INDOOR UNIT OUTDOOR UNIT HP -1 GARAGE LEVEL BATTERY ROOM 300 11.3 10.7 MBTUH 53.7/51.3 AIR TO AIR -- -- -- -- -- -- CARRIER MODEL UPS ROOM MBTUH HEATING 52SQA312---3 HP -2 GARAGE LEVEL MISC EQUIPMENT 320 13.1 12.0 MBTUH 53.7/51.3 AIR TO AIR -- -- -- -- -- -- CARRIER MODEL UPS ROOM STORAGE MBTUH HEATING 52SQB314---3 I I AHU-1B GARAGE LEVEL UPS ELECTRONICS 6,000 136.9 162.6 58.9/58.6 AIR TO AIR -- 95F DB 460 / 6.0 460 / 20 CARRIER MODEL 40RUA INDOOR REPLACED UNIT AHU-1 WITH INTEGRAL FILTER BANK FOR 2" DISPOSABLE FILTERS AND 5 KW 460 VAC 3 PH ELECTRIC HEAT STAGE, 713 LBS FAN COIL, 340 LB FO: EC4 0 , E" R -410A REFRIGERANT, 2.5 LBS PER CIRCUIT, 2 CIRCUITS IN 40RUA FAN COIL, 8 LBS IN 38AU CONDENSOR UPS ROOM CFM MBTUH MBTUH 3 PH 3 PH UNIT WITH 38 AUZ OUTDOOR UNIT. MIN SEER 11.0 AC -7S SOUTH ROOF SOUTH ELEV MACH ROOM 1900 52.3 MBTUH 56.1 MBTUH 80/67 CT -1S 12.7 GPM 80.0/60.0 460/1 3.4 460/3 7.8 MON RQ -004 -3 -V -E709-000 809 LBS. OPERATING WEIGHT, INTEGRAL FILTER BANK FOR 2" DISPOSABLE FILTERS WFFH 30% EFFICIENCY, UNITFLA 11A, UNIT MCA 13A UNITMCP 20A R -410A REFRIGERANT, 2.5 LBS PER CIRCUIT, 2 CIRCUITS IN 40RUA FAN COIL, 8 LBS IN 38AU CONDENSOR AC -7N NORTH ROOF NORTH ELEV MACH ROOM 1900 52.3 MBUTH 56.1 MBTUH 80/67 CT -1N 12.7 GPM 80.0/60.0 460/1 3.4 460/3 7.8 AAON RQ -004 -3 -V -E709-000 809 LBS. OPERAI NG WEIGHT 95% DESIGN REVIEW REFERENCE DRAWINGS CONSTRUCTION NOTES REVISION CONDENSER WATER 1141 1E J, 989082 BUILD CONFERENCE ROOM N.4 710060-00 RECONFIG CR TO TRN ROOM 71277300 CAS -OPERATIONS CENTER 150550-00 GOLD CARE OFFICE DLPANSION 150686-00 or FSI LM THOMAS LM THOMAS IAA THOMAS LM THOMAS APNLOYID 011E SYR REVISOR 12.21.98 G H CAS OPS CENTER MECH 150689-00 REPLACE CRITICAL COOUNG SYSTEM 9266456 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 EN IM THOMAS IM THOMAS FS APPROVED WDH DATE 07/27/06 09.28.09 10.03.13 WDH WD8 09/08/05 04/20/06 gLBOE/HG® ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION 6 APPROVED DRAWN BDR 01LCIQD RSN DANE 12.14.98 12.15.98 SUBTRLE HVAC EQUIPMENT SCHEDULES RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER hFSi consulting engineers Seattle, Washington CURRENT RC1SION W1696197 SYMBOL Solutions & Service H DATE 10.03.13 APPROVED BY DEPT. DATE MRS CNECKED 12.11.98 APPROVED APPROVED PRE 11-14 MAJOR PASSENGER ELEVATOR REPAIR MECHANICAL MASTER BUILDING 11-14 SHEET M2A AMINO. COMP NO. DUWAMISH DWG ND. 11-14-M2A 1 1 > 12> 12> PUMP SCHEDULE SIZE DESCRIPTION MANUFACTURER MARK LOCATION SERVICE PUMP FLUID MOTOR (1) MANUFACTURER AND MODEL NOTES TEMP ('F) I — TYPE FLOW TOTAL TYPE TEMP (GPM) HEAD (FT) (T) BHP HP V PH HZ RPM P -7S 1 SOUTH 1ST FLR MECH RM CONDENSER WATER IN—UNE CENTR. 360 107 WATER 90 13 15 460 3 60 1750 PACO VL 4012-1 11.4 INCH IMPELLER (2) (3) (4) (5) (6) 8' DIA T—BAR CEILING SUPPLY DIFFUSER KRUEGER 6500 P 240 CFM 0 NC 30 10' DIA T—BAR CEILING SUPPLY DIFFUSER KRUEGER 6500 P 325 CFM ® NC 31 12' DIA T—BAR CEILING SUPPLY DIFFUSER KRUEGER 6500 P 390 CFM 0 NC 30 P -1S 1 SOUTH PH MECH RM CONDENSER WATER IN—UNE CENTR. 650 132 WATER 90 -- 40 460 3 60 1750 PACO VL 4012-7 11.5 INCH IMPELLER (2) (3) (4) (5) (6) P -2S 1 SOUTH PH MECH RM CONDENSER WATER IN—UNE CENTR. 650 132 WATER 90 -- 40 460 3 60 1750 PACO VL 4012-7 11.5 INCH IMPELLER (2) (3) (4) (5) (6) P -3S 1 SOUTH PH MECH RM CONDENSER WATER IN—UNE CENTR. 300 68 WATER 90 -- 15 460 3 60 1750 PACO VL 4012-7 xx.x INCH IMPELLER (2) (3) (4) (5) (6) 60 2950 FANTECH FRD 16-8 MAKE UP AIR FAN FOR GAS FIRED HOT SF—OL—M-19.2 hIKEU WAILR HLAILR CENTR. 499 WAILN HEAILR LUCAILU IN FLUMULNS (.RIB P -1N 1 NORTH PH MECH RM CONDENSER WATER IN—UNE CENTR. 922 104 WATER 90 -- 40 460 3 60 1750 PACO VI. 4012-7 11.0 INCH IMPELLER (2) (3) (4) (5) (6) P -2N 1 NORTH PH MECH RM CONDENSER WATER IN—UNE CENTR. 922 104 WATER 90 -- 40 460 3 60 1750 PACO VL 4012-7 11.0 INCH IMPELLER (2) (3) (4) (5) (6) P -6N 1 NORTH PH MECH RM CONDENSER WATER IN—UNE CENTR. 400 75 WATER 91 -- 10 460 3 60 1750 PACO L 3095-5 xx.x INCH IMPELLER (2) (3) (4) (5) (6) P -3N 1 NORTH PH MECH RM COOL TWR WATER IN—UNE CENTR. 1152 75 WATER 90 -- 40 460 3 60 1750 PACO VL 4012-7 10.6 INCH IMPELLER (2) (3) (4) (5) (6) P -4N 1 NORTH PH MECH RM COOL TWR WATER IN—UNE CENTR. 1152 75 WATER 90 -- 40 460 3 60 1750 PACO VL 4012-7 10.6 INCH IMPELLER (2) (3) (4) (5) (6) P -5N 1 NORTH PH MECH RM COOL TWR WATER IN—UNE CENTR. 340 104 WATER 81 -- 15 460 3 60 1750 PACO VL 3095-5 xx.x INCH IMPELLER (2) (3) (4) (5) (6) 1 13> SCHEDULE NOTES: (1) PROVIDE PREMIUM EFFICIENCY MOTOR PER WASHINGTON STATE ENERGY CODE. (2) PROVIDE INLET SUCTION DIFFUSER WITH STRAINER. (3) PROVIDE FLOOR STAND AND PIPE STANDS. (4) WEIGHT 572 LBS. (5) PUMP SIZED FOR FUTURE DATA CENTER EXPANSION, WITH REQUIREMENT OF 360 GPM. AT PRESENT, FLOW RATE IS ADJUSTED TO 315 GPM. (6) PROVIDE PUMP SUBMITTAL FOR APPROVAL PRIOR TO STARTING CONSTRUCTION. DIFFUSER SCHEDULE SIZE DESCRIPTION MANUFACTURER VENDOR P/N CFM &NOISE PERFORMANCE NOTES NOTES TYPE FLOW (CFM) TOTAL HEAD (IN WC) TYPE TEMP ('F) I — SURFACE MOUNTED EXHAUST REGISTER SHOEMAKER 900H F/B RPM 1 — SURFACE MOUNTED TRANSFER GRILLE SHOEMAKER 900H F/B AIR 55 1.5 — SIDEWALL MOUNTED SUPPLY REGISTER SHOEMAKER 900 HVO 1750 GREENHECK BSQ-180-20 6' DIA T—BAR CEILING SUPPLY DIFFUSER KRUEGER 6500 P 155 CFM 0 NC 30 8' DIA T—BAR CEILING SUPPLY DIFFUSER KRUEGER 6500 P 240 CFM 0 NC 30 10' DIA T—BAR CEILING SUPPLY DIFFUSER KRUEGER 6500 P 325 CFM ® NC 31 12' DIA T—BAR CEILING SUPPLY DIFFUSER KRUEGER 6500 P 390 CFM 0 NC 30 14' DIA T—BAR CEILING SUPPLY DIFFUSER KRUEGER 6500 P 425 CFM 0 NC 30 SF—OL—G.2-12 15' DIA T—BAR CEILING SUPPLY DIFFUSER KRUEGER 6500 P 490 CFM 0 NC 32 95 F 0.5 1/2 277 1 60 1750 TPI ( MARKEL ) 1 12'X8' T—BAR CEILING SUPPLY DIFFUSER TITUS 350RL—SS 350 CFM ®NC 25 SUPPLY DIFFUSER CD -1 12'X8' T—BAR CEILING RETURN GRILLE TITUS 35ORL—SS 350 CFM 0 NC 25 RETURN GRILLE RG -1 4 MFH—E-1500-11KW , (2) (3) (6) (7) FAN SCHEDULE MARK LOCATION SERVICE FAN FLUID MOTOR ( ) MANUFACTURER AND MODEL I NOTES TYPE FLOW (CFM) TOTAL HEAD (IN WC) TYPE TEMP ('F) BHP HP V PH HZ RPM SF—ON-017 GARAGE LEVEL OSA TO AC—ON—P16 IN—LINE CENTR. 5000 0.5 AIR 55 1.5 2 460 3 60 1750 GREENHECK BSQ-180-20 1437 NOM FAN RPM (2) (3) (4) (5) (6) MECH SHAFT SF—OL—G.2-12 GARAGE LEVEL WARM AIR TO LOBBY IN—UNE 590 TO 0.5 AIR 95 F 0.5 1/2 277 1 60 1750 TPI ( MARKEL ) 1 ALSO SEE ELECTRIC DUCT HEATER EDC -3N CENTR. 1470 MFH—E-1500-11KW , (2) (3) (6) (7) SF—OL—M-19.1 GARAGE LEVEL MAKE UP AIR FOR GAS IN—UNE 50 TO 0.5 AIR 95 F 0.5 1/20 115 1 60 2950 FANTECH FRD 16-8 MAKE UP AIR FAN FOR GAS FIRED HOT SF—OL—M-19.2 hIKEU WAILR HLAILR CENTR. 499 WAILN HEAILR LUCAILU IN FLUMULNS (.RIB I RF -1N GARAGE LEVEL BUILDING EXHAUST CENTRIFUGAL 75000 1.5 AIR 95 F 40.4 50 460 3 60 1725 GREENHECK 66—AF , 532 NOM FAN RPM, 326T ODP MOTOR FRAME RF -2N MECH SHAFT FROM ALL FLOORS RF -1S GARAGE LEVEL BUILDING EXHAUST CENTRIFUGAL 75000 1.5 AIR 95 F 40.4 50 460 3 60 1725 GREENHECK 66—AF 1 532 NOM FAN RPM, 326T ODP MOTOR FRAME RF -2S MECH SHAFT FROM ALL FLOORS EF -1 BATTERY ROOM EXHAUST FOR BATTERY IN—LINE 350 0.375 AIR 95 F 1/20 120 1 60 GREENHECK GW -85—D1 1500 NOM FAN RPM AND EQUIPMENT ROOM SCHEDULE NOTES: (1) PROVIDE PREMIUM EFFICIENCY MOTOR PER WASHINGTON STATE ENERGY CODE. (2) WITH INLET FILTER BOX (3) HORIZONTAL HANGING BASE WITH NEOPRENE ISOLATORS (4) WITH MOTOR COVER AND BELT GUARD (5) WITH VARIABLE INLET GUIDE VANES FOR AUTOMATIC OPERATION (6) SCR MOTOR SPEED CONTROL (7) WITH DISCONNECT REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION LEGEND GENERAL NOTES 1 1 > SEE SHT M326 AND M533 1 2 > PUMP SUPPUED WITH STANDBY POWER TO RUN DURING UTILITY OUTAGES 3 > COMBUSTION SIZED SIZED PER 2003 IMC SECTION 706, MINIMUM FAN DELWERY OF 275 CFM 4) 95% DESIGN REVIEW 11-14S PUMP DETAILS. LARGE PUMPS GE MODEL 5K324JL2394, 1775 RPM, 60HZ. 105.8/52.9 AMPS, 230 / 460 V 16.1 KVAR. 40 C RATED B—DP NEMA DESIGN 324 JM FRAME TYPE K, CODE G, NEMA EFF 90.2 SMALL PUMPS, US MOTORS UNIMOUNT 125, MODEL 8083A 10 HP, 1755 RPM, FRAME 215 JM TYPE UTE SF 1.25 CODE H, INSUL CLASS F. NEMA EFF 88.5 FL AMPS 28.9/27.2/13.6 208/230/460 REFERENCE DRAWINGS CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER • FSi consulting engineers Seattle, Washington Solutions & Service REVISION A B c D INITIAL RELEASE CAS -HVAC FOR MULTI -FUNCTION ROOM DESIGN / INSTALL HVAC SYSTEM REPLACE HOT WATER BOILER INSTALL VFDS ON SHAFT EXHAUST FANS 150686-00 150685-03 567893-00 586000-00 5973-10 LW LM THOMAS LM THOMAS LM THOMAS LM THOMAS LM THOMAS APPROVED ODE sYM REVISION APPROVED DATE WDB 04.24.06 E 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 FSi 10.03.13 WDH CFH 02.12.08 07.08.08 ACCEPTABILITY T LS DESIGN OR SPECIFICATION MU ROVED IJA THOMAS 04.18.06 SUB$LE EQUIPMENT SCHEDULE - HVAC CURRENT READON W1696197 SYMBOL E DATE 10.03.13 APPROVED BY DEPT. DATE ENWNLUN LM THOMAS 04.18.06 'CHECKED APPROVED TITEE 11-14 MAJOR PASSENGER ELEVATOR REPAIR MECHANICAL MASTER BUILDING 11-14 SHEET M2G JOB ND. COMP NO. DUWAMISH G'ND 11-14—M2G INTAKE OMPR NOLs 0 -RBE AREA TYP-OF-AL 6N0 SEE 618 FOR RETURN PIPING 3/4' LINES, LIQUID REFRIGERANT 3PPER SEE SHEET 818 FOR HYD PIPING SCHEMATIC 30' DN 8 CTWW - lr FIRE COOLING TOWER ROOM W2 DRA N F.D. 01 M524 EUr EMEPGFNCY EYEWASH IP -34 ECHANICAL RM IP -fol 6 6. cw ANSI 6 r DAMPER r clws B. CIwR ,1' CHEMICAL 5 & R 31 P1A101M524 \1 1jY•-MAKEUP-WA PM10 RRUSIST DAMPER SKIN -6 Nqr 721V X 3611 OA INTAKE LOWER 11 1' CHEMICAL SUPP Y 1' CHEMICAL RETU FLUID COOLER PIPING CONNECTIONS SCALE 1/4-=1'0' DETAIL PM10 M 26 TOILET EXHAUST 7210 X 3611 LOWER PLENUM RMS 3/4' GAS, 1/2' UOUID REFRIGERANT LINES, FLARED COPPER SOUTH TOWER PENTHOUSE PLAN SCALE: 1/8" _, 1'-0" IDE COMPLIANCE D FOR \t. CODE APPROVED JAN 2 3 2014 City of 'Tukwila BUILDING DIVISION GENERAL NOTES: A, NOTE FOR STRUCTURAL ENGINEER - ROOF SUPPORT AT COOUNG TOWER MUST DEFLECT NO MORE THAN 0" WHEN LOADED. VERIFY PLYNTH HEIGHT, WIDTH, AND LENGTH 13 > MITSUBISHI MR SUM SPLIT SYSTEM AIR CONDITIONER. SEE SHEET M2a FOR RATINGS. SEE SHEET 4M11 FOR LOCATION OF UNIT ON 4TH FLOOR 14 > REFRIGERANT PIPING KITS FOR MITSUBISHI MR SUM SPLIT SYSTEM AIR CONDITIONER. 3/8" COPPER LIQUID SIDE, 5/8" COPPER GAS SIDE. FLARED CONNECTIONS REMOVAL SYM REVISION 61 APPROVED DATE SYM REVISION EN 011E c ADDED KITCHEN EXHAUST FANS & 071.5 RD 10/27/88 H RECONFIG CR TO 1129 ROOM 71277300 LM THOMAS D 11-14 EYEWASH J08 571035 LS 12/14/94 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 FSi 10.03.13 E 11-14 EYEWASH J08571035 571035 QC LS 02/10/04 F AS -BUILT 571035 OC LS 03/09/94 G INSTALL CHECK VALVE 006005 EFL EFL 05/03/99 II cel _AOE/M ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE RD/BH CH EKED CHECKED APPROVED APPROVED 0 /14/88 REMOVAL NOTES REMOVE EXISTING EXHAUST FAN, LOUVER AND ASSOCIATED CONTROLS AND DUCTWORK. REMOVE EXISTING LOUVER. REMOVE EXISTING MOTORIZED DAMPER, ACTUATOR AND ANY ASSOCIATED WIRING. O 95% DESIGN REVIEW PENTHOUSE HVAC PLAN AND ELEVATION RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER • FSi consulting engineers Seattle, Washington CURRENT REVISION W1696197 SYMBOL Solutions Sr Service J DATE 10.03.13 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14S MECHANICAL MASTER COL. C -D/4-8 DUWAMISH PM 10R OB N0. COMP N0. DWG N0. 11-14S-PM1OR /. • ll�ll / /i/ // / / FOR ENLARGED PENTHOUSE REMOVAL PLAN, SEE SHEET 11-14S—PM1OR 1101.1 MECHANICAL RM rPI 1 / Ll tur PIENUY RN I ELEVATOR MAamNE RI/ x ® I® I s COOU C TOWER Y --I- I+ % Fl-IIn F� iii-r� t' G ®' 7C Ti 'Tip REMOVAL NOTES REMOVE EXISTING EXHAUST FAN, LOUVER AND ASSOCIATED CONTROLS AND DUCTWORK. REMOVE EXISTING LOUVER. // COMPOSITE ROOF PLAN SOUTH TOWER SCALE: 3/32=1'0 RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER REMOVAL Ali REVIEWED FOR CODE COMPLIANCE APPROVED CD JAN 2 3 2014 City of Tukwila BUILDING DIVISION 95% DESIGN REVIEW • FSi consulting engineers Seattle, Washington Solutions & Service REVISION Rf DATE BENSON DATE 11-14 MAJOR PASSENGER ELEVATOR REPMR W1696197 10.03.13 ACCEPTABILITY THUS DESIGN MID/OR SPECIFICATION IS APPROVED iu iR'ows CHECRED DATE 03/21/01 ANDRE COMPOSITE MECHANICAL ROOF PLAN CURRENT REVISION W1696197 51180E A DATE 10.03.13 APPROVED BY DEPT. DATE ENGINEGN C APPROVED MPROVLO 11-14 MAJOR PASSENGER ELEVATOR REPAIR MECHANICAL MASTER BUILDING 11-14 COL A—G/1-12 DUWAMISH RFM3R JOB NO. COMP NO. DWC NO. 11-14S—RFM3R a TYP 0MP: CONTROL, P ONM(E LOUVER 001 FREE AREA TYP OF All LINO 1 r -- SEE 018 FOR RETURN PIPING I COOLING TOWER BOOM 1 I DRMN TOL FO I SEE SHEET MIS FOR HYD PIPING SCHEMATIC 3/4' GAS, 1/2' UOUID REFRIGERANT IMES, FLARED COPPER ARE DAM PEP 0A. INTAKE LOWER 2 P•4 P 10 O 10 U524 --1 8' CTWR e' CAWS Air �K�J1 2' ,- N 6' EYEWASH PLENUM RM =31 ECHANICAL RM 0' CAWS 6 6' lJ 4' CW 1 1/2' CW CIRMICA. S & R u;NIELLiei IP -2s1 L. 9 RG -1 325 J ELEVATOR SHAFT D -t C.0=1 350 350 350 ELEVA-OR MACHINE RM 350 16'0 SA� �%OFr RG -1 325 RG -1 325 rlak 1 1/2' MAKEUP WA %31 P tv624 B F.P BUCID)RA8DAMPER RUSKIN BD0 -0 72''Wx3611 1' CHEMICAL SUPP Y 1 CHEIOCAL RETU FLUID COOLER PIPING CONNECTIONS SCALE 1/4"=1.0" rTh PY10O DETAIL PM10 M 26 7ORET EXHAUST 72Y1 X 30TH LOUVER 3/4' GAS, 1/2' LIQUID REFRI ONES, FLARED COPPER t 1 1/2' CTWS (TOP) 1 1/2' CTWR (BOTTOM) SOUTH TOWER PENTHOUSE PLAN SCALE: 1/8" = 1'-0" REVIEWEL 1 DE COMPLIAWE APPROvFr JAN 2 3 2G1h City of Tukw, BUILDING Di-, O RG -1 I F^- 325 1 \I V6x1 16X10`RA I (DN) TO UNIT II II II II u 20X12 SA (DN) TO UNIT O GENERAL NOTES: NOTE FOR STRUCTURAL ENGINEER - ROOF SUPPORT AT COOLING TOWER MUST DEFLECT NO MORE THAN 0' WHEN LOADED. VERIFY PLYNTF HEIGHT, WIDTH, AND LENGTH MITSUBISHI MR SUM SPLIT SYSTEM NR CONDMONER SEE SHEET 02D FOR RATINGS. SEE SHEET 44811 FOR LOCATION OF UNIT ON 4111 FLOOR REFRIGERANT PIPING KITS FOR MITSUBISHI MR SUM SPLIT SYSTEM NR CONDRIONER 3/8- COPPER LIQUID SIDE. 5/8' COPPER GAS SIDE. FLARED CONNECTIONS CONSTRUCTION NOTES I INSTALL WATER -SOURCE AIR CONDRIONER. FOR EXACT LOCATION SEE ARCH/STRUCTURAL DRAWING. INSTALL SA DUCTWORK, DIFFUSERS AND ACCESSORIES AS SHOWN. ROUTE TIGHT TO ROOF. INSTALL RA DUCTWORK, REGISTERS AND ACCESSORIES AS SHOWN. ROUTE TIGHT TO ROOF. ® INSTALL CTWS AND CTWR AS SHOWN. ROUTE TIGHT UNDER DUCT. © PROVIDE ELEVATOR SHAFT DAMPER AND MOTORIZED ACTUATOR. 11E INTO EXISTING FIRE ALARM SYSTEM. © INSTALL SA DIFFUSER WITH DUCT TAP AND VOLUME DAMPER TO BOTTOM OF DUCT AS SHOWN. INSTALL RA REGISTER WITH DUCT TAP AND VOLUME DAMPER TO SIDE OF DUCT AS SHOWN. CONTINUE INSULATION AND JACKETING OVER FLEXIBLE CONNECTION FOR WEATHER PROTECTION. 95% DESIGN REVIEW RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 11 • FSi consulting gngineers Seattle, Washington Solutions & Service 1W APPROVED 081E Stu ADDED KITCHEN EXHAUST FANS & OTl5 11-14 EYEWASH JOB 11-14 EYEWASH JOB571035 AS -BUILT INSTALL CHECK VALVE 571035 571035 571035 006005 OC OC OC EFL RD LS LS LS EFL 10/27/68 RECON FIG 08 TO TRN ROOM 71277300 12/14/94 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 to LM THOMAS Mi APPROVED 10.03.13 02/10/04 03/09/94 05/03/99 BOE/ASiG' o� ACCEPTABILITY THIS 065100 AND/OR SPECIFICATION IS APPROVED RD1 DATE 01/14/88 SUBTITLE PENTHOUSE HVAC PLAN AND ELECTION CURRENT REVISION W1696197 SYMBOL j OA1E 10.03.13 APPROVED ErY DEPT. DATE ENI.INEER 'CHECKED APPROVED APPROVED 711E 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14S MECHANICAL MASTER COL C -D/4-8 DUWAMISH SHEET PM 10 JOB NO. COMP NO. DWG NO. 11-14S-PM10 © /77/7 FOR ENLARGED PENTHOUSE PLAN, SEE SHEET . 11-14S—PM10 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION COMPOSITE ROOF PLAN SOUTH TOWER SCALE: 3/32=1'0" RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 95% DESIGN REVIEW • SconWashington engineers Seattle,ii Washington Solutions & Service REVISION MTE DATE 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 FS 10.03.13 BOE/H6® ACCEPTABILITY IRIS DESIGN MND/0R SPECIFICATION IS APPROVED APPROVED 9Y DEPT. DATE THOMAS CALCI E0 03/21/01 SU5R11E COMPOSITE MECHANICAL ROOF PLAN CURRENT REVISION W1696197 6M8°` A DATE 10.03.13 hARANLtet CHECKED APPROVED APPROVED 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14S MECHANICAL MASTER COL. A—G/1-12 DUWAMISH SHEET RFM3 JOB COMP 140. CM N0. 11-14S—RFM3 MECHANICAL RM MARIAM M PU]NUM RI ELEVATOR MOM M RN COOU N® C LONER -.. •1 : REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION COMPOSITE ROOF PLAN SOUTH TOWER SCALE: 3/32=1'0" RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 95% DESIGN REVIEW • SconWashington engineers Seattle,ii Washington Solutions & Service REVISION MTE DATE 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 FS 10.03.13 BOE/H6® ACCEPTABILITY IRIS DESIGN MND/0R SPECIFICATION IS APPROVED APPROVED 9Y DEPT. DATE THOMAS CALCI E0 03/21/01 SU5R11E COMPOSITE MECHANICAL ROOF PLAN CURRENT REVISION W1696197 6M8°` A DATE 10.03.13 hARANLtet CHECKED APPROVED APPROVED 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14S MECHANICAL MASTER COL. A—G/1-12 DUWAMISH SHEET RFM3 JOB COMP 140. CM N0. 11-14S—RFM3 ELEVATO SHAFT 72w x 7271 ` SHAFTVENTSIrnnrTR Rv nTNERc SEE DETAIL PM1 M526 NG A GWB © r NOTE: SEE _ _ - - _ _ - p•/ ARCH PLANS SHT A-31 FDR _ REUff C N INTAKE LOWER % BY OTHERS / ENCLOSURE SEE ARCH PUN STAIR 'B' SHT A-36 i1 p 0 t0 r 30 FUTURE TION _ „/ L✓" V I I �I r( 1 n I I I , - PLENUM RM INSULATE & HEAT4 TRACE EXPOSED PIPE �/ SEES SVT F%0%RF1Ici1"li SCH�uTIC • MB 3/4" CW 1_m 1180 I I AM © Rt PIPE AT PUMP 91CnON DIFFUSER CONNECTION CENTER UNE � Elf ODoa DP M18 �.:41 Li I LI' Q+rs T -J P1.11.00 19u TO • ELEV SHAFT ELEV - — S s , «c t - °--- P1410 00 CT -16 SIDE BLDG SIDE 'r'i II, . I CONTR CT -IN SIDE IKKC �1 MECHANICAL -zap, BLDG SIDE " QIEr-144 QItF-tui ` DRAIN FD BY PLUMB CONTR COOUNG TOWER RM BD -6 - 1 ,� I` ���' B.F.P._� - ' F.D. 1 111 FUTURE PUMP LOCATION 10' F,YDRONIC RISER ., AS POSSIBLE L .__.___ -76. --- ,� ,.-, .4. S 1 /7 DRAM - BACKDRAFT DAMPER RL19ON L 7:111-14 36%i FIELD V1 u i1 pis EMERGENCY TOILET IXHAUSf P 10 � M 00 301' 0TFER5 x 30ii J 1lLOWER BY0 GJt © \ / `INTAKE LOWER BY OTHERS 60% FREE AREA UNE. 3/4.LAT \ / / 72w x 36'H LOWER BY OTHERS B 11-14N-PM10 M529 NORTH PENTHOUSE ENLARGED PLAN SCALE: 3/16`=1'0* REVIEWED... .�----L FOR CDDAPPROVED JAN432014 City of TONila BUILDING D 1VISIDN REMOVAL 17 LEGEND GENERAL NOTES 1 > COLUMN LOCATIONS BASED ON ORIGINAL BUILDING CONSTRUCTION I2 > COLUMN LOCATIONS BASED ON REVSION TO STANDARD BOEING COLUMN DESIGNATION 411 REFERENCE DRAWINGS 11-14N-RFM10 PARTIAL ROOF PLAN - NORTH HALF 11-14N-RFM11 PARTIAL ROOF PLAN - SOUTH HALF 11-14-M500 DETAILS, SECTIONS, & ELEVATIONS, PENTHOUSE REMOVAL NOTES REMOVE EXISTING EXHAUST FAN, LOUVER AND ASSOCIATED CONTROLS AND DUCTWORK. REMOVE EXISTING LOUVER. REMOVE EXISTING MOTORIZED DAMPER, ACTUATOR AND ANY ASSOCIATED WIRING. RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 95% DESIGN REVIEW I IISei consulting gngineers Seattle, Washington Solutions & Service STM A B C D E REVISION ADDED EF -14N & MODIFIED FAN SYSTEM ADDED CONCRETE PLYNTHS, COND PIPE DTL ADDED KITCHEN EXHAUST FANS AND DETAILS 11-14 EYEWASH 11-14 EYEWASH 571035 571035 Eff RD RD RD QC OC APPRO./ED LS LS 591 03/10/88 04/06/88 10/27/88 12/14/93 02/10/94 SYAI REVISION F G AS -BUILT REPLACE COOUNG TOWER 11-14 MAJOR PASSENGER ELEVATOR REPAIR 571035 556553-01 W1696197 BY OC LAI THOMAS FS APPROVE) LS WDH 03/09/94 11.15.06 10.03.13 g)LISFAFEASW° ACCEPTABILITY THIS DESIGN AND/0R SPECIFICATION IS APPROVED RD BH 01/14/88 SUBRTLE HVAC SYSTEMS -PENTHOUSE CURRENT REVISION W1696197 SYMBOL H DATE 10.03.13 APPROVED BY DEPT. DATE CHECKED APPROVED APPROVED TITLE 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14N MECHANICAL MASTER COL. C-D/M-Q SHEET PM10R JOB NO. COMP NO. DUWAMISH, WA DWG 00. 11-14N-PM1OR O ("1-- g) 1 ( C ) (D i0 CD C MOEN EORUST P SEE ARCH SIR A PINS LOUVER BY OTHERS PL5NUI RM NSU LATE & EAT TRACE EXPOSED PIPE 10• HYDRONIC RISER ROUTE AS POSSINI H LE i \ INTAKE LIXIVER BY OTHERS BOK FREE AREA TTP UNO. 170)6 CI FAN ROOF LEVEL PARTIAL PLAN SCALE: 3/32°=1'0° REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION REMOVAL LEGEND GENERAL NOTES REFERENCE DRAWINGS REMOVAL NOTES RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER RWSION AS BUILT BY WOOD HARBINGER 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 BY MWS FS APPROVED DATE SYM REVISION BY APPROVED DATE 02/31/92 10.03.13 ce:LAMPEFArda• ACCEPTABILITY THIS DESIGN AND/OR SPEC1F1CATON 6 APPROVED APPROVED BY DEPT. DATE TES Mss 2NWNLLN CHEWED APPROVED 11 17/92 susONE 95% DESIGN REVIEW PARTIAL ROOF PLAN - SOUTH HALF REMOVE EXISTING EXHAUST FAN, LOUVER AND ASSOCIATED CONTROLS AND DUCTWORK. REMOVE EXISTING LOUVER. KEY PLAN O SCALE: NONE N IjFSiSeattleconsulti, Washing ngton engineers Solutions & Service CURRENT REV6KIN W1696197 SYMBOL B DATE 10.03.13 TITLE 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14N MECHANICAL MASTER COL A -G/6-12 SHEET RFM11R JOB NO. COMP NO. DUWAMISH, WA DWG ND' 11-14N-RFM11R 0 SEE SHT M10 FOR FAN SCHEDULE IEF-1&+1 EF -4014 DOWN TO HOOD H-2 KITCHEN SIDE, SEE SHEET 11-14N-RFM11 TEF -17N) EF -4015 IEF-18N1 EF -4013 0 DOWN TO HOOD H-1 SERVERY SIDE, SEE SHHET 11-14N-RFM11 3 SEPERATE 2HR SHAFTS SEE DETAIL /Z\ M1OAIM50 18/18 14/20 CONN -- DUCT FOB W/22.5 Pf'A1.CJ 00 DOWN DISHWASHER alpHOOD SEE SHEET 11-14N-RF1111 14x49 3/4 DISCHARGE NORTH PARTIAL ROOF PLAN RFM11 1500 SCALE 1/4- = 1'-0" WELD DUCT TO FAN FLANGE N ,6, JBOTTOM FAN DRAIN BUILT UP ROOFING 2x8 CURB VIBRATION ISOLATION PADS SLEEPERS (EF -16N SIMILAR) SECTION SCALE: 1 /4"=1'-0" PM50 +150 WELD & SEAL TIGHT TO DUCT FLASHING SHAFT VENT AIR GAP 2x12 CURB ROOF DECK STEEL ANGLE DUCT SUPPORT WELDED TO DUCT 0 ELEVATOR MACHINE RM 66N/x12-Li ELEVATOR SHAFT VENT BEYOND BY MECH COORDINATE W/STRUCT CONTR 0 ELEVATOR MACHINE ROOM SECTION , SCALE: 1/4"=1'-0" PM101M500 ELEVATOR MACHINE RN ® ELEVATOR MACHINE ROOM A SECTION 1 SCALE: 1/4"=1'-o" PM1 f 00 30/14 DISCHARGE UP -BLAST CREASE EXHAUST FAN 20/14 FAN CONN EF -17N (EF -16N SIMILAR) SECTION SCALE: 1/4"=1'-0" PM5O)A 00 REMOVAL STAIRWELL WALL ENCLOSURE BY OTHERS 10" CONDENSER WATER SUPPLY FROM TOWER, CT -1N ROOF SLAB SHEAR WALL HYDRONIC PIPE IN STAIRWELL SECTION SCALE: 1/4"=1'-0" PM101M500 REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION O LEGEND GENERAL NOTES COOUNG TOWER ELEVATIONS 3 AND 4 RELOCATED TO SHEET 11-14-M556 95% DESIGN REVIEW REFERENCE DRAWINGS REMOVAL NOTES D REMOVE EXISTING EXHAUST FAN, LOUVER AND ALL ASSOCIATED CONTROLS AND DUCTWORK. REMOVE EXISTING LOUVER. REMOVE EXISTING MOTORIZED DAMPER, ACTUATOR AND ANY ASSOCIATED WIRING. RECEIVED CITY OF TUKWILA DEC $ 5 2013 PERMIT CENTER SYM A B BENSON BY APPRWED DATE SYM MISER APPRENED DATE ADDED EF -14N & MODIFIED FAN SYSTEM ADDED CONCRETE PLYNDIS, CONDESER PIPE DETAILS RD RD 03/10/88 04/06/88 C CONDENSER PIPE DETAIL ADDED KITCHEN EXHAUST RD 10/27/88 D 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 FSi 10.03.13 c4&715W ACCEPTABIUTY DOS DESIGN AND/OR SPEOnDAI1ON IS APPROVED RD/BH CHECKED DATE 01-14-88 SUBTITLE AFFRONTS) BY DEPT. DATE NLINEtN CHECKED APPROVED APPROVED TITLE DETAILS, SECTIONS & ELEVATIONS PENTHOUSE 11-14 MAJOR PASSENGER ELEVATOR REPAIR MECHANICAL MASTER BUILDING 11 -14N -P N/A II• FSi consulting engineers Seattle, Washington Solutions & Service CURRENT REVISION mea DA1E W1696197 D 10.03.13 SKEET M500R JOB NO. COMP NO. DUWAMISH owc ND. 11-14N-M500R 66'W X 12"H SM DUCT W/ N.O. MOTORIZED DAMPER. 110V REQ'D AT ELEVATOR MACHINE RM A SECTION SCALE: 1/4"=1'-0" PCI,..1124 0 6614 X 12 H ELEVATOR SHAFT VENT BEYOND BY MECH. COORDINATE W/STRUCTURAL CONTR AT ELEVATOR MACHINE RM SECTION SCALE: 1/4"= 1' —0" PM 11 2 N FLASHING BY MECH Fl d PIPE IL �r O CT -1S OPERATING WT = 54,695 LBS (E0 WEIGHT PER ELEVATOR) FIELD VERIFY: WOOD CURB BY OTHERS FLASHING AND SEALING BY MECH CONTR. STRUCTURAL ENGINEER: — ROOF SUPPORT AT COOUNG TOWER MUST NOT DEFLECT MORE THAN 5/8" WHEN LOADED. — VERIFY PLYNTH HEIGHT, WIDTH. AND LENGTH. SPRING ISOLATION MASON SLR -417 TYPICAL OF 6 TOP OF ROOF DECK 9" 9 12'-0" AT COOLING TOWER L ' SECTION rim SCALE: 1/4"=1'-0" PM1 2 AT COOLING TOWER SECTION SCALE: 1/4"=1'-0" 0 z w O REMOVAL REMOVAL NOTES REMOVE EXISTING EXHAUST FAN, LOUVER AND ALL ASSOCIATED CONTROLS AND DUCTWORK. © REMOVE EXISTING MOTORIZED DAMPER, ACTUATOR AND ANY ASSOCIATED WIRING. REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION STRUCTURAL ENGINEER: —ROOF SUPPORT AT COOUNG TOWER MUST NOT DEFLECT MORE THAN 0' WHEN LOADED —VERIFY PLYNTH HEIGHT, WIDTH, AND LENGTH 95% DESIGN REVIEW RECEIVED CITY OF TUKWILA DEC 052013 PERMIT CENTER • FSi conengineers Seattle,11 Washington Solutions & Service RDASOI Hr APFRaum DATE SIM Hr APPROY D HATE ADDED EF -14N & MODIFIED FM SYSTEM ADDED CONCRETE PLYNTHS, CONDESER PIPE DETAILS ADDED KITCHEN EXHAUST FAN AND DETAIL 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 RD RD RD 03/10/88 04/06/88 10/27/88 FSi 10.03.13 BOE/A/G® I ACCEPTABILITY 1165 DESIGN AND/OR SPECIFICADON IS APPROVED APPROVED HY DEPT. DATE RD/BH DAM - 01 -14-88 WHITTLE DETAILS, SECTIONS & ELEVATIONS CURRENT REVISKIN W1696197 5YMH0L DATE 10.03.13 ,LNi.YAELR CHECKED APPROVED APPROVED 11-14 MAJOR PASSENGER ELEVATOR REPAIR MECHANICAL MASTER BUILDING 11-14 N/A SHED M524R J00 N0. COMP N0. DUWAMISH Dwc No. 11-14—M524R O E> P , SEE DETAIL NOTE SEE ARCH PIANS SM A-31 FOR I RELIEF P 0 ( INTAKE LOUVER r BY OTHERS PM1IM526 ROUTE PIPING A GWB ENCLOSURE SEE MGI PUN STAIR 13. SHT A-361 30 FUME PUMP LOCATION P' 0 00 1 PM 51M 10 Ti 1 SEE ARCH PIANS SKI A-31 00 INTAKE LOINER.BY 0114EWS / Teo INTAKE LOUVER BY OTHERS 60% FREE AREA TVP UNO. ORYYRf FAN ROOF LEVEL PARTIAL PLAN 1 SCALE: 3/32`=1'0` REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION LEGEND GENERAL NOTES REFERENCE DRAWINGS CONSTRUCTION NOTES RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 95% DESIGN REVIEW KEY PLAN SCALE: NONE N Bi• FSi consulting engineers Seattle, Washington Solutions & Service STY A B RDASEN AS BUILT BY WOOD HARBINGER 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 BY MWS FSi APPROVED DATE 02/31/92 10.03.13 sYM REVISION et APPRO+FD DISE BOE/A%G® ACCEPTABILITY KMS DESIGN AND CR SPECff1 400N 6 "DRAWN TES MWS ENGINEER APPROVED BT DEPT. DATE X11 17 92 SUBRRE PARTIAL ROOF PLAN - SOUTH HALF CURRENT REVISION W1696197 SYMBOL B DATE 10.03.13 NECKED APPROVED APPROVED TIRE 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14N MECHANICAL MASTER COL A -G/6-12 DUWAMISH, WA 6NE>T RFM 11 JOB 140. COMP N0. DWG N0. 11-14N-RFM11 0 SEE SHT M 1 0 FOR FAN SCHEDULE EF -4014 DOWN TO HOOD H-1 SERVERY SIDE, SEE SHHET 11-14N—RF1111 3 SEPERATE 2H SHAFTS SEE DETAIL / Z� M10A1M500 DOWN TO HOOD H-2 KITCHEN SIDE, SEE SHEET 11-14N-10111 IEF-17N1 EF -4015 Iff-1BNI EF -4013 18/18 P &tly 0 14x49 3/4 DISCHARGE NORTH PARTIAL ROOF PLAN SCALE 1/4" = 1'-0' RFM10 WELD k SEAL TIGHT TO DUCT FLASHING SHAFT VENT AIR GAP 2x12 CURB r ROOF DECK VIBRATION ISOLATION PADS SLEEPERS (EF -16N SIMILAR) SECTION SCALE: 1/4"=1'-0" PM50 0 STEEL ANGLE DUCT SUPPORT WELDED TO DUCT 66'Wx12"H ELEVATOR SHAFT VENT BEYOND BY MECH COORDINATE W/STRUCT CONTR ® ELEVATOR MACHINE ROOM SECTION SCALE: 1/4"=1'-0" PM10�M 00 ELEVATOR MACHINE RM ELEVATOR SHAFT RELIEF BEYOND © ELEVATOR MACHINE ROOM A SECTION SCALE: 1/4"=1'-O" PM10[ 00 30/14 DISCHARGE UP -BLAST GREASE EXHAUST FAN 20/14 FAN CONN EF -17N (EF -16N SIMILAR) SECTION SCALE: 1/4"=1'-0" PM50�1500 66 W..12"H HSM DUCT ' X. STAIRWELL WALL ENCLOSURE BY OTHERS I 10" CONDENSER 11 WATER SUPPLY FROM TOWER, CT -1N ROOF SLAB SHEAR WALL HYDRONIC PIPE IN STAIRWELL SECTION SCALE: 1/4"= 1'- 0" PM 1 00 REVIEWED CODE COMPL APPROVED JAN 2 3 2014 LEGEND GENERAL NOTES 1) COOLING TOWER ELEVATIONS 3 AND 4 RELOCATED TO SHEET 11-14-M556 City of Tukwila BUILDING DIVISION REFERENCE DRAWINGS CONSTRUCTION NOTES PROVIDE ELEVATOR SHAFT DAMPER AND MOTORIZED ACTUATOR. TIE INTO EXISTING FIRE ALARM SYSTEM. RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 95% DESIGN REVIEW I miFSi consultingWahi engineers Seattle, Washington Solutions & Service SYM RD16CN IW A ADDED EF -14N & MODIFIED FAN SYSTEM 8 ADDED CONCRETE PLYNIHS, CONDESER PIPE DETAILS CONDENSER PIPE DETAJL C ADDED KITCHEN EXHAUST 0 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 APPROVED RD RD RD TWE 03/10/88 04/06/88 10/27/88 Sn REVISION BY *PREMED DATE FSI 10.03.13 0;LAirArmziv; 'I' ACCEPTABIUTY T105 DESIGN Alm/OR SPECIFICATION 16 APPROVED RSD BH 01-14-88 SUBBRE DETAILS, SECTIONS & ELEVATIONS PENTHOUSE C1IRRENT TENSION W1696197 SYMBOL D GATE 10.03.13 APPROVED B1 DEPT. DATE LAG1NktN CHECKED AYYROJLD APPROVED 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11 -14N -P SHEET M500 JOB N0. COUP N0. MECHANICAL MASTER N/A DUWAMISH DWG NG. 11 -14N -M500 AT ELEVATOR MACHINE RM A SECTION SCALE: 1/4"=1'-0"PMI_ 1524 66-W X 12"H ELEVATOR SHAFT VENT BEYOND BY MECH. COORDINATE W/STRUCTURAL CONTR AT ELEVATOR MACHINE RM SECTION SCALE: 1/4"=1'—O" PM1 524 ri PIPE LL FLASHING BY MECH TOP OF ROOF DECK 0 4 9" O O O CT -15 OPERATING WT = 54,695 LBS (EO WEIGHT PER ELEVATOR) 12'-0" 5'-6" AT COOLING TOWER /110 SECTION SCALE: 1/4"=1'-0" PM1 2 CT -1S SEE NOTES IN 13s LEVEL UNIT & ISOLATION FRAME FIELD VERIFY: WOOD CURB BY OTHERS FLASHING AND SEALING BY MECH CONTR. STRUCTURAL ENGINEER: - ROOF SUPPORT AT COOUNG TOWER MUST NOT DEFLECT MORE THAN 5/8" WHEN LOADED. - VERIFY PLYNTH HEIGHT, WIDTH, AND LENGTH. SPRING ISOLATION MASON SLR -417 TYPICAL OF 6 0 1 PLYNTH �0 1'-6" 3-6" 8'-9 1/4" 8-9 1/4" _ 1 -6" M -IN 8'-11 1/2" AT COOLING TOWER SECTION SCALE: 1/4"=1'-0" PMM24 L v x §REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila BUILDING DIVISION STRUCTURAL ENGINEER: m -ROOF SUPPORT AT COOUNG TOWER MUST NOT DEFLECT MORE THAN D" WHEN LOADED -VERIFY PLYNTH HEIGHT, WIDTH, AND LENGTH 95% DESIGN REVIEW 61 APFRCKD DATE REASON 81 DALE ADDED EF -1411 & MODIFIED FM SYSTEM ADDED CONCRETE PLYNTHS, CONDESER PIPE DETAILS RD RD 03/10/88 04/06/88 ADDED KITCHEN EXHAUST FAN AND DETAIL RD 10/27/88 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 FS1 1003.13 BGE/A!G® ACCEPTABILITY 11115 DESIGN AND/OR SPECIFICATION 6 APPROVED APPROVED BY DEPT. DATE RD/BH CHECKED 01-14-88 SUBTITLE DETAILS, SECTIONS & ELEVATIONS CONSTRUCTION NOTES PROVIDE ELEVATOR SHAFT DAMPER AND MOTORIZED ACTUATOR. TIE INTO EXISTING FIRE ALARM SYSTEM. RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER • FSi consulting engineers Seattle, Washington Solutions & Service CURRENT REVCJON W1696197 SYMBOL D DATE 10.03.13 'iAL F&Lx CHECKED APPROVED APPROVED TIS 11-14 MAJOR PASSENGER ELEVATOR REPAIR MECHANICAL MASTER BUILDING 11-14 N/A SHEET M 524 JOB NO. COUP NO. DUWAMISH ONE 11-14—M524 ELEVATOR SHAFT DAMPER MOTOR SP5A/3 SP5A/35 e ELEVATOR SHAFT DAMPER MOTOR F (C DOWN TO PANEL SP5A/12,14 (5th FL)II FROM 5D3/22b S SWICHED BY PHOTOCELL CONTROL IN PTHSE DOWN TO 5th FL OVERHEAD TO BOEING LOGO SIGN EXTERNAL EAST WALL PE60 E50 ( H FIRE (ALARM RELAY I I I I SPA/33! .=f3 GFCI 33 SP5A/33 A/C COMPRESSOR 208/230V,1 PH,2HP FAN UNIT IN RM 43J4 / SP5A/33 SP5A/33 PHOTOCELL CONTROL INTER TIC K4221 sxP/a SOUTH TOWER PENTHOUSE PLAN SCALE: 1/8"=1'-0" SYN RENS/ON BY APPROVED DQE SYM REVISION BY APPROVED DATE A REWIRE HEAT TRACE D99F1085 COOK JRC 4/15/99 8 INSTALL CIRC. PUMP PJ006647 COOK JRC 6/30/99 C COMP LAB WC UPGRADE 712773-00 PENOZA 4/24/01 0 BOEING LOGO SIGN 713802-00 PENOZA 5/22/01 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 BrN 10.03.13 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED 0 DATE SUBDUE GENERAL NOTES 1) ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED 2) AU. WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120 208V 277 1_OV 'A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EQUIPMENT GROUND GREEN 4) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPIATELY COLORED TAPE. 5) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAYS. 6) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7) DYMO LABEL ALL RECEPTACLES. J -BOXES. SWITCHES. ETC., WITH CIRCUIT IDENTIFICATION. 8) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. REFERENCE DRAWINGS: 11-14S-RE60 FOR ROOF POWER OTHER THAN PENTHOUSE CONSTRUCTION NOTES PROVIDE AND INSTALL NEW SURFACE WALL MOUNTED RECEPTACLE, GFCI TYPE WITH AN IN -USE CAST ALUMINUM WEATHERPROOF COVER. PROVIDE WEATHERPROOF MOTOR RATED DISCONNECT SWITCH, MOUNT SWITCH TO DAMPER HOUSING. PROVIDE NEW FIRE ALARM MONITORED RELAY FOR CONTROL OF NEW ELEVATOR SHAFT DAMPER MOTORS. REFER TO FIRE ALARM DRAWING E502. ® RUN CONDUIT DOWN EXISTING SLEEVE TO MECHANICAL ROOM ON LEVEL 5 BELOW. REFER TO DRAWING 5E60. SEPARATE RMI T AND AP --'SVA 195% DESIGN'y E® 120/208 VOLT POWER KEY PLAN RECEIVED CITY OF TUKWILA DEC 05 2013 PERMIT CENTER REVISION W1696197 ge SYMBOL BrN Engineering, Inc. earfar....etyawaay smAwwrAya wfa DATE 10.03.13 APPROVED BY DEPT. DATE N ECKED APPROVED IE 11-14 MAJOR PASSENGER ELEVATOR REPAIR (DISIPLINE) MASTER BUILDING 11-14S COL. 4 -5/E -J DUWAMISH EEr PE60 El JO4 NO COMP N0. DWG NO. 11.145-PE60 SP5A/31,35,37,39,41 0 ELEVATOR ROOM MACHINE PH -1 4 OO S RO..IPIMP IAIED WM HEAT WE (FED MOR sraV33) CONDUIT DOWN °' 2 ROOM' 2 _ v 2 I (f 1. SP5A/33 MECHANICAL ROOM .(4 N #10 SP 6 A/�'+ . I I e120V- /12 HP SPSA 33 S 3 OGLING TOWEP ROOM PH -4 A la b FIRE (ALARM RELAY I I I I SPA/33! .=f3 GFCI 33 SP5A/33 A/C COMPRESSOR 208/230V,1 PH,2HP FAN UNIT IN RM 43J4 / SP5A/33 SP5A/33 PHOTOCELL CONTROL INTER TIC K4221 sxP/a SOUTH TOWER PENTHOUSE PLAN SCALE: 1/8"=1'-0" SYN RENS/ON BY APPROVED DQE SYM REVISION BY APPROVED DATE A REWIRE HEAT TRACE D99F1085 COOK JRC 4/15/99 8 INSTALL CIRC. PUMP PJ006647 COOK JRC 6/30/99 C COMP LAB WC UPGRADE 712773-00 PENOZA 4/24/01 0 BOEING LOGO SIGN 713802-00 PENOZA 5/22/01 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 BrN 10.03.13 ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED 0 DATE SUBDUE GENERAL NOTES 1) ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED 2) AU. WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120 208V 277 1_OV 'A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EQUIPMENT GROUND GREEN 4) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPIATELY COLORED TAPE. 5) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAYS. 6) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7) DYMO LABEL ALL RECEPTACLES. J -BOXES. SWITCHES. ETC., WITH CIRCUIT IDENTIFICATION. 8) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. REFERENCE DRAWINGS: 11-14S-RE60 FOR ROOF POWER OTHER THAN PENTHOUSE CONSTRUCTION NOTES PROVIDE AND INSTALL NEW SURFACE WALL MOUNTED RECEPTACLE, GFCI TYPE WITH AN IN -USE CAST ALUMINUM WEATHERPROOF COVER. PROVIDE WEATHERPROOF MOTOR RATED DISCONNECT SWITCH, MOUNT SWITCH TO DAMPER HOUSING. PROVIDE NEW FIRE ALARM MONITORED RELAY FOR CONTROL OF NEW ELEVATOR SHAFT DAMPER MOTORS. REFER TO FIRE ALARM DRAWING E502. ® RUN CONDUIT DOWN EXISTING SLEEVE TO MECHANICAL ROOM ON LEVEL 5 BELOW. REFER TO DRAWING 5E60. SEPARATE RMI T AND AP --'SVA 195% DESIGN'y E® 120/208 VOLT POWER KEY PLAN RECEIVED CITY OF TUKWILA DEC 05 2013 PERMIT CENTER REVISION W1696197 ge SYMBOL BrN Engineering, Inc. earfar....etyawaay smAwwrAya wfa DATE 10.03.13 APPROVED BY DEPT. DATE N ECKED APPROVED IE 11-14 MAJOR PASSENGER ELEVATOR REPAIR (DISIPLINE) MASTER BUILDING 11-14S COL. 4 -5/E -J DUWAMISH EEr PE60 El JO4 NO COMP N0. DWG NO. 11.145-PE60 • 4 �l 0 1.-3#4 THW, U COMBINATION MOTOR STARTER/DISC SW SIZE 1', NEMA1 120V, COIL —I (69 7 1/2 HP, 480V CIRCULATING UMP O \ .J I ® A i 40 PU4P0V• 0 ARI C SOV •�, PUMP, PLENUM ROOM PH-2 3/4.-3 18— 1 1/4'-3 #4,3 •8 THHN, CU - SE- .3, ')' 7, 9,11 IEC -351 /25 HP,480V, Q 30, ELEV CONN 3/4'-3 88 ELE AT PPCCONN HILAE ROOM PH --1 C % .4.6 % : � / / /r'J 13,15,17 2 3 2 3 SE13,15:17 FVNR j 50 HP: P -2S 40HP PUMP 12 \ 1 I SMCC 1 1/2'-3 /12. / 1'-3N4 THW - SXL-14,16,18 SMC TEF-15 3 HP ,480V, 3A, EXH. FAN MECHANICAL ROOM sLlcc sMCc PH : _ k 0 THW.CU� O M PP. 100 pp 03 T52W 7 :. 50 HP : CTIS :� 40HP HI SPD \ I� SMCC 'alr°� - n `YF.., - = 1112— 10HP ID SPD. NI - 1'-3 4 IOHP SPD 10HP 10 SPG j1 1114QU � THW,CU •12 91 U U (11. 1: • 40 P 6 W1 HP SHP 40 P 6 0 HP HIGH SUMPLOW SPRAY HIGH SUMPLOW -- 3/4--3 3/4•-3 8 / SPEED HTR SPEED PUMP SPEED HTR SPEED THHN, CUJ' SXL-20, S0MSA-38, 4 22,24 ,42-. _,OOLING TOV\ ROOM PH -4 I -ICC -1 S 3 HP,480V, 30, COMPRESSOR CONN MOTOR CONTROL CENTER SCHEDULE SECT 3 5 ID DESC 2 SECT 4 5 ID DESC Z SECT 1 5 ID DESC 2 SECT 2 9 ID DESC 21 05 FVNR :. : 50 HP P -4N P -1S 40HP PUMP oA yy,,w 105 FVNR j 50 HP: P -2S 40HP PUMP Na- = '''' " ' M PP. 100 pp 03 T52W 7 :. 50 HP : CTIS :� 40HP HI SPD 0350 HP : CTS : HI 'alr°� - n `YF.., - = ...' 10HP ID SPD. NI - 0. rAG _ IOHP SPD 10HP 10 SPG • CTIS SUMP PUMP •• TEF -1S 3HP EXHAUST FAN SMCC SYM A 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 By BrN APPROVED 011E SYM REVISION TO SNCL TO 8XL/20,22,24 TO SMCC Y. HP 40'HP SPRAY HIGH PIMP SP® CTIS DISCONNECT RACK BY APPROV0 DATE 10.03.13 L&17AEFAW EF -131 3 �H, EXP,480V,HF 3. c—isI F P,480V, ELEV CONN P,480V, ELEV ELEV CONN 16 #8 THHN CU `EFu14S PANEL SE \\ 1 1/2 HP,480V, \ 311, EXH. FAN \- MOTOR STARTER MOTOR STARTER SIZE b0', 120V SIZE '0', COIL TO CONTROL COIL TO CONTROL EF -14S EF -36S REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN RMYHRE DATE 06-28-90 CHECKLD CHECKED APPROVED APPROVED SUBTITLE GENERAL NOTES 1) ALL CONDUIT TO BE 1/2' E M.T. UNLESS OTHERWISE NOTED 2) ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V PHASE (LEFT BUS IN PANEL) BLACK BROWN 'B' PHASE (CENTER BUS IN PANEL) RED ORANGE 'C' PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EOUIPMENT GROUND GREEN 4) ALL NEUTRAL WIRES TO SYSTEM FURNITURE POWER POLES SHALL BE A MINIMUM OF #10 COPPER IN SIZE. 5) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPIATELY COLORED TAPE. 6) ALL UNUSED CONDUIT ANO WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAYS. 7) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 8) DYMO LABEL ALL RECEPTACLES, J -BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 9) ALL VAV FAN MOTORS TO BE F.H.P. AS NOTED, 277V, 1 . 10) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 11) ALL TERMINAL UNITS RATED 480V,3Cp SHALL HAVE 30 AMPS/3P, 4W SAFETY SW WITH 20 AMP FRS FUSES. LEGEND 4 FAN, 480V, 30/ .C). FAN, 277V, 10/ CONSTRUCTION NOTES DEMOLISH EXISTING ELECTRICAL CONTROL EQUIPMENT, CONDUIT AND CONDUCTORS BACK TO PANEL NE FOR EXISTING FANS EF -13S AND EF -14S. LABEL THE CIRCUIT BREAKER AS SPARE. EpiP eta w/ A/ �� 95% DESK*V e ,VD 277/480 VOLT P01 `t;�! TITLE 11-14 MAJOR PASSENGER ELEVATOR REPAIR ELECTRICAL MASTER BUILDING 11-14S NO RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER COL. J -E/4-5 DUWAMISH B® BrN Engineering, Inc. e.mrma�roe„�..I,y P ..W,.Aa.,a,aPI Peeps �> NT REVIS1ON SYMBOL A DATE W1696197 10.03.13 JOB PE110R COMP NO. E2 DWG N0. 11.145 -PESO (7 1--304 THW,CU-\ COMBINATION MOTOR STARTER/DISC SW SIZE 1-, NEMA1 120V, COIL -r { P -3S I 7 1/2 HP, 480V, 3,0, CIRCULATING .UMP O O I\ ) {cc 3 P.4 l� R 3p,. COMPRESSOR CONN MOTOR CONTROL CENTER SCHEDULE SECT 3 9SECT 4 $SECT 1 S SECT 2 9 ID DESC 2 ID 0ESC 2 ID DESC Z ID DESC 2 05 FVNR :: 50 HP: P -4N P-1 40HP PUMP 03 TS2W 3 :: 50 HP CTIS 4011P HI SPD 14HP LO DPD SIAM 10 w1 yell _ SPAM 10 W 1 SAME 10 111 10 .1 02101P1 1 • OMP a - 05 FVNR 3 50 HP: P-25 t 40HP PUMPI 03 TS2W E SNP 40HP M SPD 10HP LD SPD • CTIS SUMP PUMP •• TEF -1S 3HP EXHAUST FAN SMCC TO BMOC HP HIGHSPEED w HEMP J TO SXU20,2224 --;vi, 10 P 7. HP LSPFwED PIMPY SUMP HTR J TO SMCC INHP 10 IDS® LOW SPEED CTIS DISCONNECT RACK ISI HP,480V, ELEV CONN 251 4P,480V, �I.EV CONN -6 18 THHN CU SE -8,10.12 112 IAC -7S) 11.2FLA,4804, 30. AIR COND. O GENERAL NOTES 1) ALL CONDUIT TO 8E 1/2- E.M.T. UNLESS OTHERWISE NOTED 2) ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/2084 277/480V -A- PHASE (LEFT BUS IN PANEL) BLACK BROWN -B- PHASE (CENTER BUS IN PANEL) RED ORANGE -C- PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EOUIPMENT GROUND GREEN 4) ALL LIM NEUTRAL WIRES COPPER SYS SIZE.FFURNITURE POWER POLES SHALL BE A 5) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPIATELY COLORED TAPE. 6) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAYS. 7) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 8) DYMO LABEL ALL RECEPTACLES, J -BOXES, SWITCHES. ETC., WITH CIRCUIT IDENTIFICATION. 9) AU. VAV FAN MOTORS TO BE F.H.P. AS NOTED, 277V, 1 . 10) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 11) ALL TERMINAL UNITS RATED 480V,3QXSHALL HAVE 30 AMPS/3P, 4W SAFETY SW WITH 20 AMP FRS FFUSES. LEGEND FAN, 480V, 30 FAN, 277V, 10 CONSTRUCTION NOTES PROVIDE SINGLE POINT CONNECTION TO AIR CONDITIONING UNIT AC -7S. INTEGRAL DISCONNECT SWITCH FURNISHED BY EQUIPMENT MANUFACTURER. PROVIDE NEW 3//12,1/2'C. TO EXISTING CIRCUIT BREAKER IN EXISTING PANEL SE. SEAL ALL WALL PENETRATIONS. PROVIDE 1/2" CONDUIT AND JUNCTION BOX FOR THERMOSTAT LOW VOLTAGE CABLE FROM AC -7S TO INSIDE ELEVATOR MACHINE ROOM. COORDINATE LOCATION OF INTERIOR JUNCTION 80X PRIOR TO ROUGH -IN. SEAL ALL WALL PENETRATIONS. RECEIVED CITY OF TUKWILA pDECps 0 5 2013 �$ j PERMIT CENTER Q'701 Uin �4 BrN Engineering, Inc. et rymtalComenormawY0 95% DESIGN REVIEW °� "� SYI1 Ifo APPROVED DATE 94 APPROVED DATE A 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 BrN 10.03.13 .BOE/AW ACCEPTABILITY THIS DESIGN AND/0R SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN RMYHRE TRECRED DATE 06-28-90 SUBTITLE 277/480 VOLT POWER CURRENT REVISION W1696197 SYMBOL DATE 10.03.13 59GINLLN CHECKED APPROVLD APPROVED TITLE 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14S ELECTRICAL MASTER COL. J -E/4-5 DUWAMISH SHEET PE110 E3 JOB NO. COMP N0. DWG N0. 11.145-PE60 0. PU480V, HP48DV •0. PUMP PLENUM ROAM PH -2'•':._ 3/4--3 18— 1 1/4--314,318 481, 19CU - \ 7 9,113,5. ELEVATOR MACHINE ROOM PH -1 •911 IEC -351 / 25 HP,480V, ELEV CONN 3/4--3 18 EC -451 40 HP,480V, 30. ELEY CONN O/ 2.4.6 PANEL SE SE -2.4 6,13,15,17 13 15,17 2 3 • 2 O 30 12 \ 1 h succ /1 SMCC 1 1/2--3112_ 1HW.&4-, SXL-14,16,18 Q THW,C`U SMG . i 112 1--3N4 12 �r 1 THW, U 112 fJ QQ 0 Q QQ 0' 12 TEF -1• 40 6 WIHP6HP 40 P 6 0 HP HIGH SUMPLOW SPRAY HIGH SLAMR.OW SPEED HTP SPEED PUMP SPEED HTR SPEED 2 ' TsR ROOM OOLING TO PH—4 SXL-20, 22.24 3/4--3 8 / 3 IE,480V, 30,EXH. FAN THHN, Cu3)f, MSA -3$, 40,42-. MECHANICAL ROOM SM‘ PHS sum j 1"-3p4 i THW,C`U "---2L I\ ) {cc 3 P.4 l� R 3p,. COMPRESSOR CONN MOTOR CONTROL CENTER SCHEDULE SECT 3 9SECT 4 $SECT 1 S SECT 2 9 ID DESC 2 ID 0ESC 2 ID DESC Z ID DESC 2 05 FVNR :: 50 HP: P -4N P-1 40HP PUMP 03 TS2W 3 :: 50 HP CTIS 4011P HI SPD 14HP LO DPD SIAM 10 w1 yell _ SPAM 10 W 1 SAME 10 111 10 .1 02101P1 1 • OMP a - 05 FVNR 3 50 HP: P-25 t 40HP PUMPI 03 TS2W E SNP 40HP M SPD 10HP LD SPD • CTIS SUMP PUMP •• TEF -1S 3HP EXHAUST FAN SMCC TO BMOC HP HIGHSPEED w HEMP J TO SXU20,2224 --;vi, 10 P 7. HP LSPFwED PIMPY SUMP HTR J TO SMCC INHP 10 IDS® LOW SPEED CTIS DISCONNECT RACK ISI HP,480V, ELEV CONN 251 4P,480V, �I.EV CONN -6 18 THHN CU SE -8,10.12 112 IAC -7S) 11.2FLA,4804, 30. AIR COND. O GENERAL NOTES 1) ALL CONDUIT TO 8E 1/2- E.M.T. UNLESS OTHERWISE NOTED 2) ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/2084 277/480V -A- PHASE (LEFT BUS IN PANEL) BLACK BROWN -B- PHASE (CENTER BUS IN PANEL) RED ORANGE -C- PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EOUIPMENT GROUND GREEN 4) ALL LIM NEUTRAL WIRES COPPER SYS SIZE.FFURNITURE POWER POLES SHALL BE A 5) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPIATELY COLORED TAPE. 6) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAYS. 7) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 8) DYMO LABEL ALL RECEPTACLES, J -BOXES, SWITCHES. ETC., WITH CIRCUIT IDENTIFICATION. 9) AU. VAV FAN MOTORS TO BE F.H.P. AS NOTED, 277V, 1 . 10) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 11) ALL TERMINAL UNITS RATED 480V,3QXSHALL HAVE 30 AMPS/3P, 4W SAFETY SW WITH 20 AMP FRS FFUSES. LEGEND FAN, 480V, 30 FAN, 277V, 10 CONSTRUCTION NOTES PROVIDE SINGLE POINT CONNECTION TO AIR CONDITIONING UNIT AC -7S. INTEGRAL DISCONNECT SWITCH FURNISHED BY EQUIPMENT MANUFACTURER. PROVIDE NEW 3//12,1/2'C. TO EXISTING CIRCUIT BREAKER IN EXISTING PANEL SE. SEAL ALL WALL PENETRATIONS. PROVIDE 1/2" CONDUIT AND JUNCTION BOX FOR THERMOSTAT LOW VOLTAGE CABLE FROM AC -7S TO INSIDE ELEVATOR MACHINE ROOM. COORDINATE LOCATION OF INTERIOR JUNCTION 80X PRIOR TO ROUGH -IN. SEAL ALL WALL PENETRATIONS. RECEIVED CITY OF TUKWILA pDECps 0 5 2013 �$ j PERMIT CENTER Q'701 Uin �4 BrN Engineering, Inc. et rymtalComenormawY0 95% DESIGN REVIEW °� "� SYI1 Ifo APPROVED DATE 94 APPROVED DATE A 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 BrN 10.03.13 .BOE/AW ACCEPTABILITY THIS DESIGN AND/0R SPECIFICATION IS APPROVED APPROVED BY DEPT. DATE DRAWN RMYHRE TRECRED DATE 06-28-90 SUBTITLE 277/480 VOLT POWER CURRENT REVISION W1696197 SYMBOL DATE 10.03.13 59GINLLN CHECKED APPROVLD APPROVED TITLE 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14S ELECTRICAL MASTER COL. J -E/4-5 DUWAMISH SHEET PE110 E3 JOB NO. COMP N0. DWG N0. 11.145-PE60 (A) ') (( ' (E' ( F 4. 17 Alp Fy (6) C) 17 17 53C'6 17 52C 5C8 -19a,21 b 15 51Cf "C 17 1(91), 3(R2) 3/4"C - 15 Q17 41 18 DI 5 541:5 1r18 18 20 508-15,1 7. 24,36,38 5,13 36 5301. 5C8-1,3,5,13,14 16,18,20.22 54D5 I I 5C8 -37,39I(/ 5C8- 21 ,28,30, 32,34.36.38 - 38 CD 6 8 5D8-25.27, 4,16 3 4"1 15 5C8-7,9,41(DED) 40,42,26,28 31 5D8-1 5D8 2, 1n 017 5D8-8,10 39,41 33.41 36.38 40,42 5C8 CEA NG 5D8- 25.27, �?(? 29.33.35 25C8-11,23 25,27 5C3-18,20,22, 24,26.28 9 42 S2E5 1-G 1L`• 5A/9 11 A 31 10"X12"X8" 4A/28o 1/2' 2112,1120 3/4" DI 5D8 7,9 ,9 5D8-37, 36.38,40,42 33.35 • 53E5 27, 23 25 52E1: 27 5505 (R' SYM V 5406 CONDUJL TO 50851 E6 5106 • 5C8-10,12 124;2 FROM PANEL 5C3 REVSiON 5206 MOVE POWER POLE J9D99M0715 INSTALL 8 LCD MONITORS ELEV LEY Jp565662-02 BUILD HR SERVICE CENTER 9369-10 MODIFY CUBICLE W1027183 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 9 8^�8 L 5C8-29, 31,8 29 29 SDPS 31 m JP5A 7SP5A/9,1 1,21 C 53Z 52E4 )m 0 4TH F 0 5D8-13, 19.21 15,19,21 ,•• W 1, 3 0 3 2F5 294. 2 ErE 2 CONDUIT UP - TO PENTHOUSE _\t 2 BY COOK HABTE STEWART HABTE BrN APPROVED JRC CAS DATE 03 09.99 04 27.06 10 07.10 04.17.12 10.03.13 SYM REVISION FOR CONTINUATION SEE SHEET 5A11 0 R 5 BUILD (2) NEW OFFICES INSTALL DUPLEX OUTLET INSTALL DUAL OUTLET/PHONE CONSTRUCT (1) OFFICE INSTALL SYSTEM FURNITURE JjD79M1448 J/D70M0062 JID79M1968 J1D79M1904 31989167-00 BY COOK COOK COOK COOK COOK 5D8-1,3 3 APPROVED JRC JRC JRC JRC JRC 3/4" `- I`- . 'SP5A-h3 DI 15,17 DI 15 O(1) 3/4 u= DATE L f a .Ym 10 07 97 11 04 97 11 18 97 11 1897 02 06 98 ci_41,401E4lAW' MATCHLINE ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN R MYHRE LHLLKEU DATE 07.06.90 SUBTITLE LEGEND 1. REFER TO SHEET Ela FOR ELECTRICAL SYMBOLS AND ABBREVIATIONS. REFER TO SHEETS E1b AND E1c FOR RECEPTACLES LEGEND. QjU WALKERMOLD 1700 MULTI -OUTLET PLUG STRIP GENERAL NOTES 1. UNLESS OTHERWISE NOTED, CONDUIT IS 1/2" EMT. 2. UNLESS OTHERWISE NOTED, WIRE IS STRANDED COPPER, TYPE THWN INSULATION, #12 AWG FOR POWER AND #14 AWG FOR CONTROL. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS: 208Y/1 20V 480Y/277V A0 (LEFT PNL. BUS) BLACK BROWN B0 (CENTER PNL. BUS) RED ORANGE CO (RIGHT PNL. BUS) BLUE YELLOW NEUTRAL WHITE GREY EQUIPMENT GROUND GREEN GREEN ISOLATED GROUND GRN/YEL. GRN/YEL* 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TYPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAYS. 6. ALL NEUTRAL WIRES TO SYSTEM FURNITURE POWER POLES SHALL BE A MINIMUM OF 11l0awg COPPER. 7. PERMANENTLY LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH PANEL AND CIRCUIT IDENTIFICATION. POST REVISED PANEL SCHEDULES IN ELECTRICAL PANELS UPON COMPLETION OF JOB. REFERENCE DRAWINGS 1. SEE 11.14S -E2 FOR 208Y/120V FEEDERS TO PANELS AND BUSWAYS. SEE 11.145-E3 FOR 480Y/277V FEEDERS TO PANELS AND BUSWAYS. CONSTRUCTION NOTES PROVIDE NEW CIRCUIT UP TO PLENUM ROOM PH2 LOCATED ON PENTHOUSE LEVEL ABOVE FOR NEW MOTORIZED SHAFT DAMPERS. USE EXISTING SLEEVE IN THIS LOCATION FOR PATH TO PENTHOUSE MECHANICAL ROOM. REFER TO DRAWING PE60. 5E60 RECEIVED CITY OF TUKWILA 5E61 Pk9,04A EEC 052013 , 0 4, RMI CENTER FQ� Vq �... 95% DESIGN REVIEW 208Y/120 VOLT POWER CURRENT REVISION W1696197 ge SYMBOL BrN Engineering, Inc. y "Amu wa5.011AWrA� lM m DATE 10.03.13 APPROVED BY DEPT. DAIS EN4IN N CHECKED APPROVED APPROVED TITLE 11-14 MAJOR PASSENGER ELEVATOR REPAIR ELECTRICAL MASTER BUILDING 11-14S COL. A -G/1-7 DUWAMISH, WA SHEET 5E60 E4 JOB 740. COMP N0. DWG N0. 11 -14S -5E60 16044C: 04/18/12 07:54 ELEVATOR SLANT DAMPER MOTOR 7 P. 35 W R.P ELEVATOR MACHINE LOOM ELEVATOR SLANT DAMPER MOTOR PPM NSULA113) MTH HEAT T (FED FROM NPS4/2S) m PLENUM ROOM PH -9 CONDUIT DORM MECHANICAL ROOM PH - (3 33 • 3 E -SP./33 11.P1 Ora FIRE ALARM RELAY REVISION 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 BY BrN APPROVED SWH NG 303 HEAT TAPE U HP5y29 NORTH TOWER PENTHOUSE PLAN SCALE: 1/8"=1'-0" SYM 8T APPROVED DATE 10.03.13 .,vu FaNGRI HW TA (FED ROM�wsVss) COOLI4G TOWER ROOM PH -4 HAP/ ,BOE/NG' o- D ACCEPTABILITY THIS DESIGN MND/0R SPECIFICATION IS APPROVED DRAWN 'CREDITED APPROVED BY DEPT. DATE DATE NGINLLN CHECKED APPROVED APPROVED SUBTITLE TITLE O GENERAL NOTES 1) ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED 2) ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RICHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EQUIPMENT GROUND GREEN 4) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL 8E IDENTIFIED WHEREVER VISIBLE BY APPROPIATELY COLORED TAPE. 5) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAYS. 6) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7) 0180 LABEL ALL RECEPTACLES, J -BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 8) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. CONSTRUCTION NOTES PROVIDE AND INSTALL NEW SURFACE WALL MOUNTED RECEPTACLE, GFCI TYPE WITH AN IN -USE CAST ALUMINUM WEATHERPROOF COVER. PROVIDE WEATHERPROOF MOTOR RATED DISCONNECT SWITCH, MOUNT SWITCH TO DAMPER HOUSING. PROVIDE NEW FIRE ALARM MONITORED RELAY FOR CONTROL OF NEW ELEVATOR SHAFT DAMPER MOTORS. REFER TO FIRE ALARM DRAWING E502. ® RUN CONDUIT DOWN EXISTING SLEEVE TO MECHANICAL ROOM ON LEVEL 5 BELOW. REFER TO DRAWING 5E61. RECEIVED KEY PLAN CITY OF TUKWILA DEC OSLA3 PERMI iP VON Oq 95% DESIGN R �7 0/ C i1y 120/208 VOLT POWER GVJ 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14N ELECTRICAL MASTER COL J -E/4-5 96197 BrNEngineering,Inc. t* 210Y0NnR &,,ir]D R.rA,vrwoma,a Fv: SYMBOL A PE60 DATE 10.03.13 E5 JOB N0. COMP NO. DUWAMISH DWG ND. 11.14N-PE60 JRC/04.4.99/1305 SIM B C 0 0 -I P-191 40 HP,480V, 30, SPRAY PUMP I P -2N J 40 HP,480V, 30, SPRAY PUMP 5 P—N6 10 HP,480V, 30, SPRAY PUMP 13,15,17 /4 —3 88� THHN U' NE -13,15; 7,2,4,6 2,4 6 r40 HP,480V, 3p, ELEV CONN ELEVATOR RO I, PH IEC -1N SEC-3NI 40 HP,480V, 25 HP,480V, 30, ELEV CONN 30. E.5V CONN--..„.„, IEC -2N1 3/4"-3 8 EC -414 40 HP,480V, 30, ELEV CONN 114iCHINE 7,9,11 1 1/4'-3 A4 3 8, THHN CU\ 3,5 NE -1,3, 5,7,9,11 PANEL NE 1 EF -14 1 1/2HP,480V, 30, EXH. FAN MOTOR STARTER SIZE "00", 120V COIL TO CONTROL EF -14 —EF -131} 3 HP,480V, 3p, EXH. FAN MOTOR STARTER SIZE "0', 120V COIL TO CONTROL EF -36N TO PAL NXPH 480VAC C 311 H Oo A MOTOR STARTER WIRING DIAGRAM 480V CPT OLs PLENUM ROOM PH -2 MOTOR CONTROL CENTER SCHEDULE ID DSECTESC Z ISC ZZ1ID ESC Z 05 FVNR 03 FVNR OS FVNR , :: 50 HP : :: 50 HP :: 50 HP P -4N P -3N P -1N I40HP PUMP 40HP PUMP 40HP PUMP 1. - 103 TS2W '03 TS2W 'OS FVNR sD HP 50 HP : 01 ,., TEF—IN DRN P -2N 10 '' 3HP FAN SPARE P,vl 1004 CB ONVL 50HP HI SPC 40HP PUMP k o� Io o :- CT114 15HP LO SPC OR DOOR JI o� ,yip _ NMCC REVISICN PROVIDE DUWAMISH UPS REPLACE COOUNG TOWER 11-14 MAJOR PASSENGER ELEVATOR REPAIR 4570590 4556653-01 W1696197 6T &MORGAN SSH BrN 041E SIM 1 IP 3N 40 HP,480V, 3p, CIRCULAyTING PUMP THw,c J MECHANICAL ROOM- PH- �IP 4N} 40 HP,480V, NM5A-38, CIRCULATING PUMP 40,42 1"-3 4` / THW.Cu NMC NMCC NXP f II NJI;ACC1 PENTHOUSE PLAN SCALE: 1/4"= 1'-0" BT APPROVED DATE A PE110 E4A 1/2"C,3/10 THHN ,CU NXPH/7,9,11 I CC—IN 1 4P,480V, Sp! COMPRESSOR—CONN' TEF -1 3 HP,48uv, 3p, EXH. FAN r 114012 / I Bt2 /60 P 5 K I6P9KW HIGH PAN HIGH PAN 8P® HTR SPEED HTR 1 1/4"-3 82,THW,CU COOLING TOWER ROOM PH -4 CTI -LI TO`NXX/1,6,6 TO NNCO 'O -POLE, DT J TRANSFER SW TO MCC J J 17 Jr II VFD VFD L 6C HP 6CHP NIGH HIGH SPEED 6P® W 6 PAN HTR PAN NTR CTIN DISCONNECT RACK PE110 PE110 10/26/06 10.03.31 REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPE0FlCAOON IS APPROVED DRAWN RMYHRE 000E 06-28-90 SUBi1RE GENERAL NOTES 1) ALL CONDUIT TO 8E 1/2" E.M.T. UNLESS OTHERWISE NOTED 2) ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/4809 'A' PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EOUIPMENT GROUND GREEN 4) A LLIM E RRA 8WIRES1OCOPPER SYSNTEM F. FURNITURE POWER POLES SHALL BE A 5) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL 8E IDENTIFIED WHEREVER VISIBLE BY APPROPIATELY COLORED TAPE. 6) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG—IN CIRCUIT BREAKERS ON BUSWAYS. 7) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 8) DWI) LABEL ALL RECEPTACLES, J—BOXES, SWITCHES. ETC., WITH CIRCUIT IDENTIFICATION. 9) ALL VAV FAN MOTORS TO 8E F.H.P. A5 NOTED, 277V, 1 . 10) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 11) ALL TERMINAL UNITS RATED 480V, SHALL SHALL HAVE 30 AMPS/3P, 4W SAFETY SW 99TH 20 AMP FRS FUSES. LEGEND 4 FAN, 480V, 30/ 'Q' FAN, 277V, 10/ CAUTION: BUILDING FLOOR SLABS ARE PRE -TENSIONED. X-RAY ALL LOCATIONS PRIOR TO DRILLING, PENETRATING OR ANCHORING TO FLOOR SLABS. CONSTRUCTION NOTES DEMOLISH EXISTING ELECTRICAL CONTROL EQUIPMENT, CONDUIT AND CONDUCTORS BACK TO PANEL NE FOR EXISTING FANS EF -13N AND EF -14N. LABEL THE CIRCUIT BREAKER AS SPARE, ES•p pq�9T 14R�rTgN RFS Rpkit O 95% DESIGN REVI 277/480 VOLT POWER RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER CURRENT REVISION W1696197 geadd,* Camay Elphealm SYMB0L BrN Engineering, Inc. 110000 01.1m0MM DATE 10.03.13 APPROVED BY DEPT. DATE ENGINEIR CHECKED APPROVED APPROVED TIRE 11-14 MAJOR PASSENGER ELEVATOR REPAIR BUILDING 11-14N ELECTRICAL MASTER COL. J -E/4-5 DUWAMISH SHEETPE110R E6 JOB NO. C011P N0. DWG NO. 11.14N-PE60 SYM A B C 0 040 P -1N1 30. SPRAY�PUMP Ip-2NI 40 HP,480V, 33. SPRAY PUMP P-N6I 10 HP,480V, 3O, SPRAY PUMP IEC -1N1 IEC -3N' 40 HP,480V. 25 HP,480V, 30, ELEV CONN 30, ELEV CONN 3/4"-3 #8--- IEC-2N1 IEC -4N rICRPi ,480,40HP,480V,0, ELEV CONN 30. ELEV CONN ELEVATOR MACHINE ROOM PH -1 TO PAL NXPH 480VAC C r PANEL NE LE H 00 ` MOTOR STARTER 7,9,11 1 1/4"-3 B4 3 R8, THHN CU-, .3 ,5 NE -1,3. 5.7,9.11 PLENUM ROOM PH -2 WIRING DIAGRAM 480V CPT 1ITTL 120V1_ OLs MOTOR CONTROL CENTER SCHEDULE SECT 1 SECT 2 SECT 3 SECT 4 5 ID DESC 2 ID OESC Z ID DESC 2 ID DESC Z1 '05 FVNR OS FVNR 05 FVNR p1" - ::p 49 :: PS3NNP :: 50P -IN P •. G - �40HP PUMP 40HP PUMP 40HP PUMP • I �, 03 TS2W . 03 TS2W , 05 FVNR H 50 HP : :. 50 HP : o TEF -IN C11N P -2N 1O{yp11 3HP FAN 1001 co oNE SSOHP SPARE 40HP PUMP u Ira 1 II CnN MRS 1510' LO SP :OR 0004 . �uw NMCC REVISION PROVIDE OUWAMISH UPS REPLACE COOLING TOWER 11-14 MAJOR PASSENGER ELEVATOR REPAIR 4570590 4556553-01 W1696197 BY &MORGAN SSH BrN APPROVED DATE SYM REVISION 1"-3 14 THW, 1 NMCC NMCC f IP 3N� 40 HP,480V, 30, CIRCULATING PUMP 13 4, 1-1;3C1/MCC J MECHANICAL ROOiI __ NXPH IP 4N1 40 HP, 480V, NM5A-38. CIRCULATING PUMP 40,42 T1HH/2"C,3 N,� 10 NXPH/7,9,11 {CC -110 3 HP,480V,� COMPRESSOR -CONEY TEF -1 I IHT 30. EXH. FAN THW,C NMC NMC ''\ 3/ (, Ai2 NMCC { /1/2-C3 10-i I' �,�i��� THHN NXPH/ 1L/ NORTH PENTHOUSE PLAN SCALE: 1/4"= 1•-0" 8Y IPPROJED DATE I ~ 1- PE110 E4A TO NX1U1,8,5 TO NMCC \"•S -POLE DT 1 TRANSFER 8W EIL VFD J J VFD TO NYCC 60 S HP 6C'HP MOM HIGH SPEED SPEED i 1, 0012 O SO HP 5 W HIGH PAN SPEED HTR 1 1/4"-3 92,THW,C COOLING TOWER ROO PH --4 CTIN _ ,012 50 HP5 KW HIGH PAN SPEED MTR L, P-415' 1 5HP,480V, 30. CIRCULATING PUMP PAN HTR PAN HTR 1 \CTIN DISCONNECT RACK PET 10 PE110 10/26/06 10.03.13 pirAr,Avc 1 PE110 PE110 ACCEPTABILITY THIS DESIGN 0140/011 SPECIFICATION IS APPROVED !AWN RMYHRE MELTED LUTE 06-28-90 SUBTITLE 95% DE GENERAL NOTES 1) ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED 2) ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EQUIPMENT GROUND GREEN 4) ALL NEUTRAL WIRES TO SYSTEM FURNITURE POWER POLES SHALL BE A MINIMUM OF #110 COPPER IN SIZE. 5) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE 8Y APPROPLATELY COLORED TAPE. 6) ALL UNUSED CONDUIT AND WIRE TO 8E REMOVED BACK TO SOURCE, INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAYS. 7) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 8) DYMO LABEL ALL RECEPTACLES, J -BOXES. SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 9) ALL VAV FAN MOORS TO BE F.H.P. AS NOTED, 277V. 11 . 10) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. 11) ALL TERMINAL UNITS RATED 480V,3Q/SHALL HAVE 30 AMPS/3P, 4W SAFETY SW WITH 20 AMP FRS FFUUSES. LEGEND FAN, 480V, 30 `Q. FAN, 277V, 10 CAUTION: BUILDING FLOOR SLABS ARE PRE -TENSIONED. X-RAY ALL LOCATIONS PRIOR TO DRILLING, PENETRATING OR ANCHORING TO FLOOR SLABS. CONST'U TION 0 ES PROVIDE SINGLE POINT CONNECTION TO AIR CONDITIONING UNIT AC -7N. INTEGRAL DISCONNECT SWITCH FURNISHED BY EQUIPMENT MANUFACTURER. PROVIDE NEW 3#12,1/2"C. TO EXISTING CIRCUIT BREAKER IN EXISTING PANEL NE. SEAL ALL WALL PENETRATIONS. PROVIDE 1/2" CONDUIT AND JUNCTION BOX FOR THERMOSTAT LOW VOLTAGE CABLE FROM AC -7N TO INSIDE ELEVATOR MACHINE ROOM. COORDINATE LOCATION OF INTERIOR JUNCTION•BOX PRIOR TO ROUGH -IN. SEAL ALL WALL PENETRATIONS. Pp air App ..'T AN D RECEIVED CITY OF TUKWILA DEC 0 5 2013 PERMIT CENTER 277/480 VOLT POWE APPROVED 9Y DEPT. DATE ENGINEER CHECKED APPROVTD APPROVED TITLE 11-14 MAJOR PASSENGER ELEVATOR REPAIR ELECTRICAL MASTER BUILDING 11-14N COL. J -E/4-5 DUWAMISH CURRENT REVISION W1696197 SHEET BrN &dil OarnmIinneen ng. Inc. MAK Anne CP. 0s Englimfre -> SYMBOL C PE110 DATE 10.03.13 E7 JOB N0. COMP N0. DWG N0. 11.14N-PE60 12) 11) (1 0) 9O ® 0 O LEGEND D SYSTEMS FURNITURE POWER POLE ' '��+.�a ( A ) ` 3 I WaSA-3 �. YY—�—YY __.. Q YY @Y '{Y YY `YY 1 03,2 b to,3D,5c,7a '�18 r 4c,26a �) r Q X3/4 0 \ ,/ 15b(D5c 15b(DED 20,41),6c 1fa;lOD[72c NII j 19 140,1.6b 18c ■ NPSA i , 10.3b,50 7a ■■■■■■ ( S , 3/4� I'� /47 Jy EU .22b _4. 3 4' I 9 r UJ e. 24c,26a ,26a 10.166, (8 80,106,12cp I \ _ 1•C 912 �3uyO5 c190 �L' 26n(DED)Y . �. — r til t 1" li SM1 Ia,3b,5c.7o - -`I_ iµ1.Z-2a 4b,6c 19 0 ( C ■ I. 2,broeoy' 30c(DED ' . j 11 IIII ' 141 z 1-- N1 / 19 -'> _ taaa6,,18a - 11I _ 13•,1'• 7c,190 GENERAL NOTES �' 13 / ( 516 26a(DED)1 (B) - " —_ — i 1 w I r I. ALL CONDUIT TO BE 1/2"EMT UNLESS OTHERWISE NOTED. "i3 _ o _17- �n III. 1111 I1�1 11 I� wU Q) 2. ALL WIRE TO BE #12 THHN UNLESS OTHERWISE NOTED THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE it A� ;� III 5M17-14a,16b,18c I �ASPHASOE OLEFT BUSN ALL YIN2PANE0V IRjUITS: BLACK d - 1 3zo34b31 6a(DED) EIV, I� — 3/ ` 'B'PHASE CENTER BUS IN PANEL) RED 'C'PHASE RIGHT BUS IN PANEL)BLUE 16L D e_ r 35c ) r f ki 13 � 25a.27D, a`" � T� ( l NEUTRAL WHITE 336(DED) GROUND GREEN 3/4� d�,42c 3/4'\ j,� ISOLATED GND GRN/YELLOW — J 23c 2ib29c 3. DYMO LABEL ALL RECEPTACLES,JUNCTION BOXES, SWITCHES =f,'-'•71--)1 ' I �,, `\ fir �3/a'� ETC. WITH CIRCUIT IDENTIFICATION. REVISED PANEL SCHEDULES UPON COMPLETION OF t9[IIIII I J. -' L. ► 4,-320-,34b,8 I 7a.9D. 11. 3c 2 �• 9 S -326.34b 38a ) 37a.39D.41 35c DED n 1 I s� 5 17-25o 27 I titi„ 4. INSTALL JOB. ■ ��I T� lo.3b5c a 1sM17-a2F (DED ( t' 5M17-32a,34D.35cr ( a7-37aa1 - —fl I1' 5. FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 -38a(DED) t- 35c(D6D)L_!,1_7-..0 AND E3. ^ IU 1 II f�l ' '1F`' SM16A-1a,3b, Sc,iSb sMty(_ 70,9b.1-1c.SM17-2 53C3�3b(DED) 27b,2Bc NPSA-15 1 5M17 (EF 672W, -TNI fJDPS 120V Ip 1 NPS 53a15b,17c,i9o90 3a,t5bt�c 6. ALL NEUTRAL WIRES TO SYSTEM FURNITURE SHALL BE A MINIMUM OF #10. -- — " '- "13` A. —.r-?.� Jz' ` a ° r - !11 \ �•21 NPSB NPSA-9, REFERENCE DRAWINGS B 1_ �° 4 d ' 6/2172#1201213 /338 .. ( 21 _ r ^ �••T5 •15 ISI I IIII_ x- r6 PE60 — • fIIIER0XJ r ;�N IIS ENCBLIJO - I I / _.- - ABOVE CE1uNL -` 40,rotc i_ T 1SFLR Ij 1• 4 IL' Wo 0'%12'X8' `t —• -`,.. NPSA/35 III ■' - I I _ -NPP 19 II ,I _, .- �1 c c I c �: moi] ILING�] I •_21 �`i 53C O �y I ��,�,, —SIii6A'2((SP ((S, P)6(SP), / f 5Mt6 17a� 17 SM�_ CONSTRUCTION NOTES \,------;_________\%,,, � 6 _ a 1 - 5M 16A/8�10,12(DE) 5M16A/30 32,34,36:,11 SM168-19a.21b � � m prx cruse 1� PROVIDE NEWCIRCUIT UP TOPLENUMROOM PH2LOCATED ON PENTHOUSE LEVEL ABOVE FOR NEW MOTORIZED SHAFT \, SM16A 26,285M16A 20,22 24SM16A 25,27,2923c,25o(DED) " ;57,3,4415,117 f�1�i_— � II I It ISI F I mklDAMPERS. USE EXISTING SLEEVE IN THIS LOCATION FOR ROOM.REFERTO ,\ 03oaR,ww��( PATHTOPENTHOUSE MECHANICAL CI si 26awAhzOh;2>3 / 3 . ■il..'� ■ DRAWING PE60. \--"-- u3.. 36c R4 •\ ) 8a,10b,12c,1a,3b . >7 '— 3/4 I', L� — 1 �'; Pr \ r 2a,' • 6t 1a I r -,u —II o 61). 5M168=35c,37u. ••f••! ( 12 ((R3) '-39DNc(DEID) i 3b 4) J N. • _ \'' „ - —,-35c.37a,39b:41•ic I--� 35c,370,39b,41C 16 5 27 29� (F )SM 4� r1 �� N sA ) WE _ I �3 ,_ EE . A %----- Allr4IP/11 III RECEIVED il CITY OF TUKW1LA 5E61 5E60 DEC 052013 PERMIT CENTER BrN Engineering, Inc. 95% DESIGN REVIEW M'°":,..r.,•,..t,ror :a= $YM REVISION BI APPROVED DATE $YM REVISION BY MPROVED DATE ; ® ci..._45,47EZArG 1 -DRAWN ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION6 cNED"KEROE NUE 08.14.90 SUBTITLE 208YI1�E CURRENT REVISION W1696197 SYMBOL U GATE 10.03.13 P ADD WKSTA PWR 2482453 STEWART 4 17 06 U 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 BrN 1003.13 SMUT 5E61 R EV0 '(��IO����jLLLjI�J1,(e�' QAj{�eL�e MAJOR P 0 f"`Bali' 7`OY VYY /'.0'-Y'YY/ ---fes :� + = k INSTALL 8 LCD MONITORS ELEV LBY J/565662-02 HASTE CAS 04.27 06 L REMOVE POWER POLE J�D99M3179 COOK JRC 1208.00 APPROVEDBYDEp1.DATE11-14 EPRDJEDTLNGINLLNTDA R REMOVE (i)PWR, (1)DATA POLE 4235259 STEWART 2 07 07 M POWER TO NEW POLE J/D99M3259 COOK JRCCHECKED BUILT 1���� L ELECTRICAL MASTER REQUIRED ,UID - DUW:r ISH JOB Na. COMP Na. APPROVED S INSTALL CABLE & POWER 4236422 SSH CAS 2/13/07 N CONSTRUCT CONFERENCE ROOM 4999078-08 BOYS 0117.00 DWG N0. 11.14N -5E61 �� T ADD DEDICATED CIRCUIT FOR COPIER W.0./7186337 MORALES CAS 06.04.08 AS BUILT BOYE 07 27.00 65,13061: 06/01/11 10, • AM J-BOXr 00 ZONE A 2-716 _ZONES2716 L POWER SUPERVISION RELAY PENETHOUSE J -BOX ZONE -2-1-1 6 5TH FLOOR • 4 116 NOTES: BREAK CIRCUIT AT "X" MARKS TO INSTALL FUTURE DETECTORS. FUTURE DETECTOR 2ND -4TH FLOOR (TYP) J -BOX 24V - 2 714 ELEVATOR CAPTURE RECALL ALTERNATE FLOOR COMMON • MAIN FLOOR SMOKE DETECTOR WIRING DIAGRAM SCALE:NONE HEAT DETECTOR 24VDC MAXIMUM 2 AMPS FROM re,PANEL � o < IDEC RH1B-U-24VDC RELAY W/SH1B-05 SOCKET 110V 1— (BY OTHERS) SHUNT TRIP I. BREAKER SPRINKLER SOLENOID (BY OTHERS) KAFKA NOTE: ONE HEAT DETECTOR REQUIRED PER SPRINKLER HEAD IN ELEVATOR SHAFT, ELEVATOR PIT, AND ELEVATOR CONTROL ROOM. TYPICAL DETECTOR7ELEVATOR CONTROL WIRING DIAGRAM SCALE:NONE REVISION 11-14 MAJOR PASSENGER ELEVATOR REPAIR W1696197 By BrN APPROVED JRC DATE SYM SPRINKLER ZONE II FLOW SWITCH FLOW SWITCH OS & Y TI s OS &Ytt SOUTH TOWER FAN SHUTDOWN -2 BY OTHERS Do- B A PENTHOUSE 414 - --�B R RJ4141 4 4 14 4 171 I TO ELEV CONTROL I CONNECTED TO 5TH FIR CIRCUIT 6 14 IQ 5TH FLR 714 �_ 211 STAIR C 2 STAIR A XI -B R 1 .A 6 14 6 .j F:2 16 H 2/16 A.\. 4TH FLR D 6 14 01. 2 j 1s© ID - B RI A R 6 141 6 ft, ©2 3RD FLR C-8 R1 -A R16141 6714 ...E.,211§042116 2ND FLR D\ 2 16 D 16 14 16 \6 11� L 2;14 STAIR C STAIR A © ©� NOTE: RISER DOES NOT SHOW QUANTITIES OF DEVICES. SEE FLOOR PLANS. NORTH TOWER STAIR B TO E CONTROL 3. CONNECTED TO 5TH FLRI L 4 CIRCUIT J BY OTHERS �A-;21B�I1- 67/1-6,1-? �714�PENTHOUSE 14 STAIR A STAIR 2C' 14 r®© A. -11R 8,->- 416i�Iv'R 4''14 4 14 2r 16 2; 16 F D ••n 5TH FLR A -' .R 4116' .' 614 6 14l D fiu , 14 © 0 2 4 4TH FLR A L,R B,I n- 16.1 )R 14 -17/11- 16 2716F-F-1 14-16©2I16rF` 0 L2' 14 © 0 A 4 3RD FLR R 61 k 8,- 74 I R 216E 2ND FLR 2716 2165© N< E9 B R-1 A R 16 14 1 4-17 6,141. N �216© 2:16 1ST FLR r -B R.1 A R1 6141 6 D 21 14 T. 6 4 58;16 28;14 HOOD VENT PLAZA 2.30 L N FRCP II FACP 3712 TO OVAC - POWER 2 161J� 58#16 26714 1114 2'16 PARKING 6 4 F 72_7JkD 2716 11 4] STAIR C STAR A 2716 ©©©110 L-"-4 • 0 ©00© 2116 P1 A.-5 R B->'- 16 2116`1'R 14 6714 2116 © 271611 1 "ST FLR A P .-1' R 6 14 6A14 P R 6 16 © 27161 i F_ PARKING TYPICAL SPRINKLER ZONE SCALE:NONE REWSION 8Y APPRDNED DATE 10.03.13 SIMPLIFIED FIRE ALARM RISER DIAGRAM ALTIFOFE— ZONE LISTS SOUTH TOWER 1 PENTHOUSE SMOKE A 2 PENTHOUSE SMOKE 8 3 5TH FLR SMOKE A 4 5TH FLR SMOKE B 5 4TH FLR SMOKE A 6 4TH FLR SMOKE B 7 3RD FLR SMOKE A 8 3RD FLR SMOKE 8 9 2ND FLR SMOKE A 10 2ND FLR SMOKE B 11 MAIN FLR SMOKE A 12 MAIN FLR SMOKE 8 13 PARKING SMOKE A 14 PARKING SMOKE B 15 DUCT DETECTOR 16 5TH FLR MANUAL/HEAT 17 4TH FLR MANUAL/HEAT 18 3RD FLR MANUAL/HEAT 19 2ND FLR MANUAL/HEAT 20 MAIN FLR MANUAL/HEAT 21 PARKING MANUAL/HEAT 22 PENTHOUSE WATERFLOW I 23 5TH FLR WATERFLOW 24 4TH FLR WATERFLOW 25 3RD FLR WATERFLOW 26 2ND FLR WATERFLOW 27 MAIN FLR WATERFLOW I 28 PARKING WATERFLOW 29 PBX HALON 30 CAFETERIA NORTH TOWER 1 2 3 45 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 BOE/NG• PENTHOUSE SMOKE A PENTHOUSE SMOKE B 5TH FLR 4TH FLR 4TH FLR 3RD FLR 3RD FLR 2ND FLR 2ND FLR MAIN FLR MAIN FLR PARKING PARKING SMOKE B SMOKE A SMOKE B SMOKE A SMOKE 8 SMOKE A SMOKE B SMOKE A SMOKE B SMOKE A SMOKE 8 DUCT DETECTOR 5TH FLR MANUAL/HEAT 4TH FLR MANUAL/HEAT 3R0 FLR MANUAL/HEAT 2ND FLR MANUAL/HEAT MAIN FLR MANUAL/HEAT PARKING MANUAL/HEAT PENTHOUSE WATERFLOW 5TH FLR WATERFLOW 4TH FLR WATERFLOW 3RD FLR WATERFLOW 2ND FLR WATERFLOW MAIN FLR WATERFLOW PARKING WATERFLOW PLAZA MANUALS MAIN FLR HALON SIGNAL ZONES SOUTH TOWER NORTH TOWER 1 PH/5TH FLR 2 4TH FLR 3 3RD FLR 4 2ND FLR 5 MAIN FLR ACCEPTABILITY THIS DESIGN ANO/OR SPECIFICATION IS APPROVE0 1 PH/5TH FLR 2 4TH FLR 3 3RD FLR 4 260 FLR 5 MAIN FLR 6 PARKING (N & S) DRAWN RMYHRE UHLLKLU APPROVED BY DEPT. DATE DATE 10.16.90 (NEER CHECKED APPROVED APPROVED SUBTULE GENERAL NOTES 1) ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED 2) ALL WIRE TO BE THWN UNLESS OTHERWISE NOTED 3) THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600 VOLTS OR LESS. 120/208V 277/480V "A" PHASE (LEFT BUS IN PANEL) BLACK BROWN "B" PHASE (CENTER BUS IN PANEL) RED ORANGE "C" PHASE (RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GREY EQUIPMENT GROUND GREEN 4) M L NEUTRUM ALfl WIRES COTOERTO MNEMZFFURNITURE POWER POLES SHALL BE A 5) LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPIATELY COLORED TAPE. 6) ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE, INCLUDING PLUG-IN CIRCUIT BREAKERS ON BUSWAYS. 7) FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 8) DYMO LABEL ALL RECEPTACLES, J -BOXES, SWITCHES. ETC., WITH CIRCUIT IDENTIFICATION. 9) INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. SYMBOLS LIST I FACP 1 7]15 (R) (P5) 7" C1 FIRE ALARM CONTROL PANEL EDWARDS 5800 (2 CANS REO'D) BACKBOX: (6537-5) 24"W X 72"H X SD MANUAL STATION EDWARDS 270 -SPO BACKBOX:4"S0 W/1 -GANG RING, MIN 2-1/20 IONIZATION SMOKE DETECTOR EDWARDS 62508 W/6251B-001 BASE 8456800: 4"OCT, MIN 2-1/80, NOT 3"OCT IONIZATION SMOKE DETECTOR EDWARDS 62508 W/6251B-003 RELAY BASE BACKBOX: 4"OCT, MIN 2-1/8"D, NOT 3"OCT PHOTOELECTRIC SMOKE DETECTOR EDWARDS 62708 W/6251B-003 RELAY BASE BLACK: 4"OCT, MIN 2-1/8"D, NOT 3"OCT HEAT DETECTOR EDWARDS 281A (135' FT/ROR) BACKBOX: 4"OCT, MIN 2-1/8"D, NOT 3"OCT DUCT SMOKE DETECTOR BY OTHERS HORN EDWARDS 882-28-001 BACKBOX: 4"SQ MIN 2-1/2"D (FLUSH MTD) HORN EDWARDS 882-28-001 BACKBOX: 8978-005 (SURFACE) SPRINKLER FLOW SWITCH BY OTHERS SPRINKLER OS & Y BY OTHERS SPRINKLER PRESSURE SWITCH BY OTHERS END -OF -UNE DEVICE RELAY NOTES: 1. SEE NEC 760-30 FOR WIRE REQUIREMENTS. 2. SEVEN (7) DAYS BEFORE PANEL HOOKUP AND CHECKOUT, NOTIFY SERVICE AT 206-324-8400. 3. ALL DRAWINGS ARE DLAGRAMATIC. ACTUAL CONDUIT ROUTING BY ELECTRICAL CONTRACTOR. 4. ALL CIRCUITS TO BE TESTED FOR OPENS AND GROUNDS WITH SIMPSON 260 METER (OR EQUIVALENT). WIRES TO BE TAGGED AND IDENTIFIED AT PANEL. IF NOT READY AT TIME SIGNAL EQUIP TECHNICAIAN IS REQUESTED TO BE ON JOBSITE, EXTRA TIME WILL BE BILLED. C• S'U TIO •T PROVIDE A NEW FIRE ALARM OPERATED RELAY MODULE FOR ELEVATOR SHAFT DAMPER OPERATION. PROVIDE NEW WIRING TO FIRE ALARM CONTROL PANEL FOR RELAY OPERATION. MOUNT RELAY ADJACENT TO FIRE ALARM TERMINAL JUNCTION BOX IN ELEVATOR MACHINE ROOM. REFER TO DRAWING PE60 FOR 120 VOLT POWER CIRCUIT CONNECTION. Sep q/i9 ,yPR Mini F c, `70 O 44 95% DESIGN RE FIRE ALARM AND SMOKE DETECTORS DETAILS,SECTIONS AND ELEVATIONS 11-14 MAJOR PASSENGER ELEVATOR REPAIR ELECTRICAL MASTER BUILDING 11-14 RECEIVED CITY OF T U K „. DEC • 0 5 2013 PERMIT Cti moi-: CURRENT 459151IN W1696197 BrN Engineering, Inc. �m em,w.oenala t SYMBOL A E502 DATE 10.03.13 COMP N0. 11.14-E502 E9 a PCS Seattle Tacoma Structural Solutions 811 First Avenue, Suite 620 • Seattle, WA 98104 • tel: 206.292.5076 1250 Pacific Avenue, Suite 701 •Tacoma, WA 98402 • tel: 253.383.2797 r' www.pcs-sauctural.00m January 7, 2014 MEMO TO: ATTN: FROM: FSi Consulting Engineers Ola Jarvegren Rick Oehmcke, S.E. RE: Boeing Building 11-14 N/S — Passenger Elevator Repair Structural Review Comments REVIEWED FOR CODE COMPLIANCE APPROVED JAN 2 3 2014 City of Tukwila COMMENTS: BUILDING DIVISION Per the City of Tukwila Department of Community Development Correction Letter #1: Comment — 1: Please provide documentation for a structural engineer licensed in the State of Washington that confirms the building's ability to support the weight of the new equipment. Response: Existing framing has adequate capacity to support the new mechanical unit loads; see attached calculations. If you have any questions or comments, please feel free to call. RMOemI 13-448 Attachment: Calculations CORRECTION 11130228 RECEIVED CITY OF TUKWILA JAN 1 3 2014 PERMIT CENTER 13448 mem 1-07-14.rmo Project: Subject. Vii& 1 [-; Shect n F �. Structural Solutions Originating Office: a't Apo'b OL (' wr aur ikteIMParte & e ( ( P rte. p6 Oter-050 7.1„ 6iftvc. phi , lGvO Lev c�-- t W ( _ � l jc> fao ') LL Rp4o type 2 ii0CL 9 Com/ 6S2. LL9r Cot (Ca.(oD-Ds t attic [] Tacoma 43a/. Job No._ Name. - Date• ittc916,z ([05zit. 14,t( 60 klopir 1.0(6 Seattle I 811 First Avenue, Suite 620 • Seattle, WA 98104 • tel: 206.292.5076 Tacoma 1250 Pacific Avenue, Suite 701 • Tacoma, WA 98402 • tel: 253.383.2797 4040 www. p cs- s t ruct ural.com 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Mechanical Summary MECH-SUM 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Info Project Address 11201 TUKWILA INTERNATION BLVD Date 1/10/2014 For Building Dept. Use corn Applicant Name: MARK CLEMENT Applicant Address: p.o. BOK 3707, M/S: 1W-10, SEATTLE WA 9912 Applicant Phone: 206-617-2944 rap Project Description Briefly describe mechanical system type and features. _] Includes Plans g"EF and louvers Upgrade existing elevator machine room "soling removing existin providing new water -source heat pump. Drawings must contain notes requiring compliance with commissioning provisions per Section C408 Compliance Option Simple System ()Complex System () Systems Analysis Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N ABU -7S AC AAON RQ -004 -3 -H -E709-000 51800 ECONO 13 N/A ECONO N AHU-7N AC AAON RQ -004 -3 -H -E709-000 51800 ECONO 13 N/A ECONO N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA cfm or Econo? I Btuh RE Output Btuh licei Efficiency's ,� Heat Recovery Y/N COpE �..._ C®Mr'L� NR A PROVE CE JA 2 3 2014 Fan Equipment Schedule • Equip. ID Equip Type Brand Name' Model No.1 CFM Sp1 HP/e a ;tr �'a Loc ion of Service ISUILDIt Service Water Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Input Capacity Sub - Category EF' Location of Service 1 If available. 2 As tested according to Table C403.2.3(1)A thru C403.2.3(8). 3 If required. d COP, HSPF, Combustion Effi gy .., roDI �y. applicable. 5 Flow control types: variable air volume (VAV), constant volume (CV), or variable speed (VS). 6 Economizer ex - • • Of f CIT OF TUKWILA CORRECTION MI?rO228 JAN 1 3 2014 PERMIT CENTER 7. Mechanical Permit Plans Checklist - Page 1 of 3 2012 Washington State Energy Code Compliance Forms for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 11201 TUKWILA INTERNATION BLVD (Date 1/10/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Deflne print area In Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS Equipment Sizing & Performance YES C403.2.1 Load calculations Load calculations performed per ASHRAE Std 183 or equivalent per Chapter 3 PLANS YESsizing C403.2.2 Equipment and system Output capacity of heating and cooling equipment and systems do not exceed calculated loads, note exceptions taken PLANS YESventilation C403.2.5 Minimum ventilation Ventilation (natural or mechanical) provided per IMC; indicate mechanical is capable of being reduced to minimum requirement per IMC PLANS YES C403.2.3 & C403.2.3.2 & C403.2.12.1 Equipment minimum efficiency Provide equipment schedules or complete MECH-SUM tables with type, capacity, efficiency, test standard (or other efficiency source) for all mechanical equipment PLANS YES C403.2.13 Electric motor efficiency Provide equipment schedule with hp, rpm, efficiency for all motors; note except. PLANS YES C403.2.10 Fan power limitation Fan system motor hp or bhp does not exceed limits per Table C403.2.10.1(1) PLANS YES C403.2.10.3 & 0403.2.13 Fractional hp fan motors Indicate fan motors 1/12 to 1 hp are ECM type or meet minimum efficiency req. PLANS N/A 0403.2.3 capacity Maximum air cooled chiller Indicate air-cooled chiller capacity does not exceed air-cooled chiller limit N/A 0403.2.1 Non-standard water-cooled chillers Full -load and NPLV values for water-cooled centrifugal chiller adjusted for non-standard operational conditions N/A 0403.2.12.1.2 Centrifugal fan cooling towers Large capacity cooling towers with centrifugal fan(s) meet efficiency requirements for axial fan open circuit cooling towers N A C403.2.3 Forced furnace and unit heaters Indicate intermittent ignition or IID, flue/draft damper & jacket loss Indicate N/A 0403.2.3.3 heating/cooling equipment Packaged electric List equipment required to be heat pumps on schedule N/A C403.2.3.4 Humidification Indicate method of humidification (note requirements for systems with economizer) HVAC System Controls & Criteria YES C403.2.4.1 Thermostatic controls Indicate locations of thermostatic control zones on plans, including perimeter systems PLANS N/A 0403.2.4.1,1 Heat pump supplementary heat Indicate staged heating (compression/supplemental) & outdoor lockout temp YES C403.2.4.2 Setpoint overlap (deadband) Indicate 5°F deadband minimum for systems controlling both heating & cooling SPECS YES C403.2.4.3 Automatic setback and shutdown Indicate zone t -stat controls with required automatic setback & manual override SPECS YESconditions C403.2.4.3.3 Automatic (optimum) start Indicate system controls that adjust equip start time to match load SPECS YES C402.4.5.2 & C403.2.4.4 Dam ers p Indicate location of OSA, exhaust, relief and return air dampers; include AMCA rated leakage and control type (motorized or gravity; note exceptions SPECS N/A C403.2.11 Heating outside a building Indicate radiant heat system and occupancy controls N/A C403.2.4.5 Snow melt systems Indicate shut-off controls based on outdoor conditions N/A C403.2.4.6 Combustion heating equipment Indicate modulating or staged control N/A C403.2.4.7 Group R1 hotel/motel systems Indicate method for guest room automatic setback & set-up of 5°F minimum N/A 0403.2.4.8 / g Group R2/R3 dwelling unit systems Indicate 5-2 programmable thermostats in primary spaces with minimum of two setback periods; note exceptions taken N/A C403.2.5.1 Demand controlled ventilation Indicate high -occupancy spaces and systems requiring DCV N/Aalternate C403.2.5.2 Occupancy sensors Indicate spaces requiring occupancy -based system control and method; or means provided to automatically reduce OSA when partially N/A C403.2.5.3 Enclosed loading dock/parkinggarage ventilationationsystem Indicate enclosed loading dock and enclosed parking garage ventilation activation and control method N/A C403.2.5.4.1 Kitchen exhaust hoods Indicate kitchen hoods requiring make-up air; indicate make-up air source and conditioning method N/A C403.2.5.4.2 Laboratory exhaust systems Indicate lab exhaust systems requiring heat recovery, method & efficiency; or altemative method taken (VAV, semi -conditioned makeup, or CERM calculation) N/A C403.2.6.1 Energy recovery - ventilation systems Indicate ventilation systems requiring ER, method & efficiency; note exceptions N/A C403.2.6.2 Energy recovery - condensate systems Indicate on-site steam heating systems requiring energy recovery C403.2.6.3 ceyste - EnerN/A ond condennseerr systems Indicate remote refrig. condensers requiring ER and use of captured energy F_. Mechanical Permit Plans Checklist - Page 2 of 3 2012 Washington State Energy Code Comp MECH-CHK for Commercial, Group R1, and > 3 story R2 and R3 Revised June 2013 Project Address 11201 TUKWILA INTERNATION BLVD IDate 1/10/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes GENERAL PROVISIONS, CONTINUED HVAC System Controls & Criteria, Continued YES C403.2.12 Variable flow control - fans/pumps Indicate fan & pump motors requiring VF control & method (VSD or equiv controls) PLANS N/A C403.2.12.1 clflow control - ling coong towers oo Indicate cooling tower fans requiring variable flow control and method N.Acooling C403.2.12.2 Large volume fan systems Indicate fan systems requiring airflow reduction based on heating and demand; or exception taken N/A C403.2.12.2 Single zone AC systems Indicate method of cooling demand -based fan control for sys. > 110,000 btuh YES C403.2.4.10 DDC system capabilities Identify all DDC system input/output control points and indicate capability for trendina and demand response setooint adjustment SPECS Ducting Systems YES C403.2.7.1 & C403.2.7.3 Duct construction Indicate all ductwork constructed and sealed per IMC, C402 leakage requirements and IBC vapor retarder requirements SPECS YES C403.2.7.3.1 Duct pressure classifications Identify location of low, medium and high pressure ductwork on plans SPECS N/A 04032.7.3.3 High pressure duct leakage test Indicate high pressure duct leakage testing requirements on plans; provide test results to jurisdiction when completed YES 0403.2.7.1 / 2 Duct insulation Indicate R -value of insulation on ductwork SPECS Piping Systems YES C403.2.8 Piping insulation Indicate R -value of insulation on piping SPECS YES C403.2.8.1 Piping insulation exposed to weather Indicate method of protection from damage/degredation SPECS SIMPLE SYSTEMS Qualifying Systems YSE 0403.3 Qualifying single zone systems Venfy unitary or packaged equipment does not exceed capacity limits, does not have active humidifcation or simultaneous heating/cooling PLANS 0403.3systems Qualifying 2 -pipe heatingN/A Verify 2 -pipe heating -only system does not exceed capacity rylimits YES C403.3.2 Hydronic system controls Refer to Complex Systems Section C403.4.3 SPECS Simple System Economizers YES C403.3.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip sched. PLANS YES C403.3.1.1.1 Air economizer capacity Indicate modulating OSA control capability up to 100% OSA, or exception SPECS YES C403.3.1.1.3 Air economizer high limit controls Indicate high limit shut-off control method per Table 0403.3.1.1.3(2) SPECS N/A 0403.1.1,2 Integrated air economizer operation Indicate capability for partial air economizer operation for systems with capacity > 65,000 btuh N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exceotion(s) COMPLEX SYSTEMS Complex System Economizers N/Asched. C403.4.1 Air economizer required Indicate cooling systems requiring economizer controls; note in equip N/A 0403.4.1.4 Economizer heating system impact Verify control method of HVAC systems with economizers does not increase building heating energy usage during normal operation N/A 0403.4.1.3 Integrated economizer operation Indicate capability for partial economizer operation for air or water econo systems N/A Moved Water economizer capacity Indicate water econo capable of 100% cooling capacity at 50°F db/45°F wb OSA N/A 0403.4.1.2 Water economizer maximum pressure drop Indicate precooling coils and heat exchangers do not exceed pressure drop limit N/A C403.3.1 Air economizer exceptions Indicate eligible exception(s) taken and provisions to comply with exceotion(s) Mechanical Permit Plans Code Compliance Forms for Commercial, Checklist - Page 3 of 3 MECH-CHK Group Rt, and > 3 story R2 and R3 Revised June 2013 2012 Washington State Energy Project Address 11201 TUKWILA INTERNATION BLVD (Date 1/10/2014 The following information is necessary to check a mechanical permit application for commercial provision compliance with the 2012 WSEC. NOTE: Define print area in Excel prior to printing MECH-CHK pages. Applicability (yes,no,na) Code Section Code Provision Information Required Location on Plans Building Department Notes COMPLEX SYSTEMS; CONTINUED Specific System Requirements N/A C403.4.2 2 C403.2.12 Variable flow control - fans Indicate fans requiring variable flow control and method N/A C403.4.2.1 VAV fan static pressure sensors Indicate sensor locations on plans; include at least one sensor per major duct branch N/A 0403.4.2.2 VAV fan static pressure setpoint Indicate fan system static pressure setpoint based on zone requiring most pressure N/A C403.4.5 VAV systems serving multi- zones Indicate supply air systems serving multiple zones that are required to be VAV, method of primary air control, and zones served; note exceptions taken N/A C403.4.5.4 VAV system supply air reset Indicate controls that automatically reset supply air temp in response to loads N/A C403.4 Large capacity cooling systems Indicate method of multi -stage or vanable control for building cooling system capacity > 300 tons N/A C403.4.7 Hot gas bypass limitation Indicate cooling equipment unloading or capacity modulation method N/A C403.4.3 Large capacity boiler systems Indicate multi -stage or modulating bumer for single boilers > 500,000 btuh N/A C403.4.3 Boiler sequencing Indicate automatic controls that sequence operation of multiple boilers N/A 0403.4.3.5 Chiller / boiler plant pump isolation Indicate capability to automatically reduce overall plant flow and shut-off flow through chillers & boilers when not in use N/A C403.4.2 & C403.4.3.6 Variable flow control - pumps Indicate pumps requiring variable flow control & method N/A 040403 2.14.4 & 0403.4.4 Varcooling towers flow control - cooling Indicate cooling tower fans requiring variable flow control and method N/A 0403.4.3.4 Hydropic system part loade,00 controls reset supply water temp AND reduce flow by a 50% for systems > 300,000 N/A 0403.4.3.2 Two -pipe changeover systems Indicate deadband, heating/cooling mode scheduling and changeover temperature range N/A C403 4 3 3 1 Water loop heat pump - deadband Indicate capability of central equipment to provide min. 20°F water supply temp deadband between heat relection and heat addition modes N/A 0403.4.3.3 Water loop heat pump - heat relection Provide heat exchanger that separates cooling tower and heat pump loop in Climate Zone 5 N/AWater C403.4.3.3.3 loop heat pump - isolation Indicate 2 -way isolation valve on each heat pump and variable flow control for systems with total pump power > 10 hp N/A 0403.4.6 Condenser water heat recovery Indicate system provided to pre -heat service water and efficiency N/A 0403.5 Cooler / freezer - anti -sweat heaters Indicate w/sf & control method for walk-in cooler/freezer door anti -sweat heaters N/A C403.5 / 6 Cooler (freezer - evaporator and condenser fans Indicate motor type for evaporator and condenser fans < 1 hp SERVICE WATER HEATING Service Water Systems N/A C404.2 Water -heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other efficiency source) N/A C404.3 Temperature controls Indicate temperature controls have required setpoint capability N/A C404.4 Heat traps Indicate piping connected to equipment have heat traps on supply & discharge N/A C404.5 Insulation under water heater Indicate R-10 insulation under tank N/A C404.6 Service water piping insulation Indicate R -value of insulation on piping; note exceptions taken N/A 0404.7 /8 Circulation systems and heat trace shut-off Indicate shut-off capability based on occupancy and periods of limited demand N/A C404.9 Group R-2 service hot water meters Indicate method of usage metering for dwell. units served by central HW system Pools & In -Ground Permanently Installed Spas N/A C404.10.1 Pool heating equip min. efficiency Provide equipment schedule or complete MECH-SUM table with type, capacity, efficiency, test standard (or other eff. source); heat pump heaters a4 COP N/A C404 10.1 / 2 Pool heater on / off controls Indicate automatic on/off control based on scheduling & accessible on/off switch on heater that operates independent of thermostat setting; or N/A C404.10.3 Pool covers Indicate vapor retardant cover and insulation rating as required N/A C404.10.3 Pool assembly insulation Indicate rating of insulation on sides and bottom of pools heated to > 90°F N/A C404.10.4 Heat recovery Indicate method, exhaust air temperature reduction and recovered energy use • City of Tukwila Department of Community Development December 19, 2013 AMY HIGHTOWER 20452 84 AVE S KENT, WA 98032 RE: Correction Letter # 1 MECHANICAL Permit Application Number M13-0228 BOEING #11-14 - 11201 TUKWILA INTERNATIONAL BL Dear AMY HIGHTOWER, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Dave Larson at 206-431-3678 if you have questions regarding these comments. • 1. Please provide documentation from a structural engineer licensed in the State of Washington that confirms the buildings ability to support the weight of the new equipment. 2. Please complete and provide a 2012 Washington State Energy Code Mechanical Summary Form. 3 All code references noted on the plans will need to be the 2012 codes. 4. Some general notes state that all work to comply with all codes and regulations in effect in Renton, WA. Please change Renton to Tukwila. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. M13-0228 !21111 Qnutlorontor Rnulounrri Quito iflnn Tulnuiln Ulnchinntnn QR150 Ahnno 711F, -441 -?/,7/) a P,, 7/11,-d21_4i/,S PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M13-0228 DATE: 01/13/14 PROJECT NAME: BOEING #11-14 SITE ADDRESS: 11201 TUKWILA INTERNATIONAL BL Original Plan Submittal Revision # before Permit Issued X Response to Correction Letter # 1 Revision # after Permit Issued DEPARTMENTS: Building Division al Public Works Fire Prevention Structural n Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable n (no approval/review required) DATE: 01/14/14 Structural Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Corrections Required (corrections entered in Reviews) Notation: Denied (ie: Zoning Issues) DUE DATE: 02/11/14 n Q Ci, \FFIcklio, Prto, �� FIA -U REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping D PW 0 Staff Initials: 12/18/2013 PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-0228 DATE: 12-05-13 PROJECT NAME: BOEING #11-14 SITE ADDRESS: 11201 TUKWILA INTERNATIONAL BL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPA TME TS: Building Division Public Works ito-r5 N/,— I)-1)—( Fire Prevention Structural Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-10-13 Complete [X] Incomplete ❑ Not Applicable n Comments: PermitCenter Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved DUE DATE: 01-07-14 Approved with Conditions n Not Approved (attach comments) Notation: REVIEWER'S INITIALS: DATE: Permit•Center:Use.Only (,� CORRECTION LETTER MAILED: 12— I `` 3 Departments issued corrections: Bldg la Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 • City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 1(1312OI ff O Response to Incomplete Letter # [Response to Correction Letter # ? O Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Plan Check/Permit Number: Pt 1 d ??B Project Name: PJOE /AiG * f / • /9/ - POW Project Address: 1 / 20/ T k-14/113 /NfH..A/f DdAJA-4- Contact Person: knly! f-/7& NT01 �._ Phone Number: 0-S-3 87 -S / S7 Summary of Revision: // 5T2WCTu C. R ✓/EvJCoM„x TS SL- G tel -e41} -Tia Aix s W' S rootTc - l i2 G yi COOE MEcJ,' /c 5-14 -, M •prt y Fort."4 • (pa Pereo 'P R -P ) l t.JG S 11/41 / GOzR.EET/ON S 4w 0 u PO4-7E-0 RECEIVED of oP TUKW LA IJAN ;1.3 2414 PERMIT CENTER Sheet Number(s): 1 d F1'Cse—S "Cloud" or highlight all areas of revision including date of rev' ion ..„../ Received at the City of Tukwila Permit Center by: Z}—Entered in Permits Plus on 1 1-1 H:\Applications\Forms-Applications On Lme\2010 Applications \7-2010 - Revision Submittal.doc Revised. Mav 2011