HomeMy WebLinkAboutPermit M13-0231 - COSTCO - ALTERATIONCOSTCO 400 COSTCO DR M13-0231 Parcel No: Address: • City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 2523049063 Permit Number: M13-0231 400 COSTCO DR Project Name: COSTCO WHOLESALE Issue Date: 12/30/2013 Permit Expires On: 6/28/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: COSTCO WHOLESALE CORPORATIO 999 LAKE DR PROPERTY TAX DEPT 006, ISSAQUAH, WA, 98027 MIKE SLOVER 19430 68 AV S , KENT, WA, 98032 KEY MECH CO OF WASHINGTON 19430 68 AV S, SUITE B , KENT, WA, 98032 KEYMEW*240NZ II I Phone: (503) 231-0731 Phone: (253) 872-7392 Expiration Date: 4/1/2015 DESCRIPTION OF WORK: INSTALLATION OF ONE (1) ROOFTOP DIRECT FIRED GAS UNIT HEATER GHU-14, RELATED PIPING AND ELECTRICAL. Valuation of Work: $54,475.00 Type of Work: NEW Fuel type: GAS Fees Collected: $892.13 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: Permit Center Authorized Signature: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: (ILAA_ 2012 2012 2012 Date: 1 • I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Date: 1 Z! 3c/ Print Name: 44--.Lm_v4 (.-1 YLY31 cV? This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 2: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 3: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 4: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 5: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 6: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 7: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 8: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 9: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 10: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 11: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 12: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 13: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 14: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 15: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. i • 16: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 17: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: I? I (0' -►3 10 to (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 252304906305 Site Address: 400 Costco Drive - Tukwila - WA 98188 Suite Number: Floor: 1st Tenant Name: Costco Wholesale PROPERTY OWNER Name: Mike Slover Name: Costco Wholesale Corporation City: Kent State: WA Zip: 98032 Address: 999 Lake Drive Email: mslover@keymechanical.com City: Issaquah State: WA Zip: 98027 CONTACT PERSON — person receiving all project communication Name: Mike Slover Address: 19430 68th Ave South City: Kent State: WA Zip: 98032 Phone: (503) 231-0731 Fax: (503) 236-5848 Email: mslover@keymechanical.com New Tenant: ❑ Yes 1..No MECHANICAL CONTRACTOR INFORMATION Company Name: Key Mechanical Address: 19430 68th Ave South City: Kent State: WA Zip: 98032 Phone: (503) 231-0731 Fax: (503) 236-5848 Contr Reg No.:K ME`s* 24014 p �aAte:g4 20 tS Tukwila Business License No.:13u S `Ol O 1 Q$""1 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Installation of one (1) rooftop direct fired gas unit heater GHU-14, related piping and electrical. 54,475 Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ • Fuel Type: Electric ❑ Gas Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9.1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm 1 Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 Signature. � Print Name: I ( t 151 R UTHORIZED T: v4A.,....S6._::..111%)__ gitk. ia� IA I, mi cli-t Date: 11/10/1 Day Telephone: Mailing Address: City H:\ApplicationsWorn -Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK I ACCOUNT _: ;,; I QUANTITY I PAID $892.13 M13-0231 Address: 400 COSTCO DR Apn: 2523049063 $892.13 MECHANICAL $892.13 PERMIT FEE R000.322.100.00.00 $681.20 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R403 R000.322.102.00.00 $178.43 $892.13 Date Paid: Monday, December 16, 2013 Paid By: KEY MECHANICAL CO OF WASHINGTO Pay Method: CHECK 2546 Printed: Monday, December 16, 2013 11:09 AM 1 of 1 WSYSTEMS • INSPECTION RECORD L-- Retain a copy with permit tYl Q -m31 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 (31 Permit Inspection Request Line (206) 431-2451 INSPECTION N0. Proje 1 Q. a -S1 et0 Type of Inspection: t= I 1,1 A- L., Address: ydv ety1.1.-eo De Date Called: Special Instructions: Date Wanted: C/ Z-1–t''t ate- m. Requester: Phone No: 3� 6-3 O 1 i Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 8,„,\\‘ - ., 1/4). U QQ /Cj, rrPov � PoJA/e \c,4e I -4 Ele64✓. 'A\ 111 Date: 4=2_I y REINSP: CTION FEE REQ IRED. P for to next inspection, fee must be paid at •300 Southcenter B ,d., Suf a 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION „e"( 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Mi? c&2.( Project: lis i,ti (AAteJAf Type of Inspectiop: f r 4 AA(A/.- Addres : Date Called: Special Instructions: (0, 64� 3 " `,0 Date Wanted: a.m. Z-05— /4 ((p.m. Requester: Phone No: � 425 145" (a.- Approved per applicable codes. Corrections required prior to approval. COMMENTS: I � 3y A: 6�5-�A Nacat A0,ft e„7- t'f S A r /4-t . , l of 7:d l'C�rfri Insector: Dat;: 4 REINSPECTION E£IRED,�Prio' t next inspection. fee must be paid at 6300 5 uthcenter Yr, Suite 100. Call to schedule. reinspection. 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit m/3 -(725/ PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Type of Inspection: Address:� Suite #: V00 C,S-{ -t) 1j Contact Person: Special Instructions: Phone No.: ylApproved per applicable codes. Corrections required prior to approval. s COMMENTS: ) k(Na_t., Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: /C Date: i y Hrs.: /. d $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • TRINE Prepared For: Costco TEI Submittal FILE COPY Date: October 28, 2013 Job Name: Costco Tukwila, WA Costco Wholesale #006 400 Costco Drive TUKWILA, WA 98188 Trane is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 Direct -Fired Gas Makeup Air Units (Outdoor) Trey Clemmer Trane 2021 152nd Avenue NE Redmond, WA 98052-5521 Phone: (425) 586-1673 Fax: (425) 643-4314 The attached information describes the equipment we propose to fumish for this project, and is submitted for your approval. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 26 2013 City of Tukwila BUILDING DIVISION x`113- Q23 RECEIVED CITY OF TUKWILA DEC 162013 PERMIT CENTER J:IJOBS11176175413161Costco Tukwila, WA DFOA Submittal Oct 28, 2013.doc Table Of Contents Product Summary1 ti Direct -Fired Gas Makeup Air Units (Outdoor) (Item Al) 3 Tag Data 3 Product Data 3 Performance Data Error! Bookmark not defined. Mechanical Specifications 4 Unit Dimensions 6 Field Wiring 9 Field Installed Options - Part/Order Number Summary 11 Direct -Fired Gas Makeup Air Units (Outdoor) 11 tri( Costco Tukwila, WA (MS Add) October 28, 2013 Ta q Data - Direct -Fired Gas Makeup Air Units (Outdoor) (Qty: 1 Item Tag(s) Qty Description Model Number Al GHU-14 1 Direct -Fired Outdoor Unit DFOA218FNH Product Data - Direct -Fired Gas Makeup Air Units (Outdoor) Item: Al Qty: 1 Tag(s): GHU-14 Unit size 218 460/60/3 main power supply Natural gas Eighth design Mod room temp ctrl & BAC view Standard gas train 1650/1350 MBH input 15 HP motor, starter, belts, drives, control transformer, disconnect Single speed energy efficient totally enclosed fan cooled 1800 RPM Horizontal arrangement 3 , bottom discharge Inlet hood and birdscreen with permanent filters UV flame sensor Disconnect switch High gas pressure regulator 1 - 5 psig (7 - 34 kPa) (FId) FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 3 of 11 Installed by Others Costco Tukwila, WA (MS Add) Mechanical Specifications - Direct -Fired Gas Makeup Air Units (Outdoor) Item: Al Qty: 1 Tag(s): GHU-14 October 28, 2(113 General Basic unit is factory assembled, wired and test fired. Based on shipping constraints, units may ship in sections due to physical size of equipment. Designed primarily for outdoor mounting, however, can be mounted indoors. Suitable for curb or slab mounting, units are mounted on steel rails with lifting Tugs. Units are available for operation on either natural or LP (Propane) gas. Basic unit casings are fabricated of die formed galvanized steel. Unit sizes 109 - 230 shall be heavy gauge. Access doors are hinge mounted with industrial type hardware for easy access to service compartments. All casings are air tight and weatherproof. Complete access is provided to all components through gasketed access doors or panels. This includes the motor, blower, burner, electrical components and manifold sections. Supply fans are double width, double inlet centrifugal type with FC fan wheels. Fans are tested in accordance with AMCA 210. The fan or fans shall be mounted on a heavy duty polished steel shaft designed for a maximum operating speed not to exceed 75% of ifs first critical speed. Bearings are to be heavy duty, industrial prelubricated type. 100,000 hour life of the bearings. Blowers to be driven by a V belt package sized with a capacity of 25% greater than the motor horsepower. Multiple belt applications will be matched sets. Drives are adjustable pitched diameter type up through 7-1/2 hp, fixed on motors over 7-1/2 hp. Burner section shall contain a burner constructed of rust resistant cast iron bodies (which serve as the gas manifold) drilled to discharge the fuel between diverging stainless steel mixing plates. The entire burner assembly is mounted directly in the air stream being heated. The fresh air stream passes through the mixing plates and mixes with the fuel as combustion air thus; all available heat from the gaseous fuel is released directly into the air stream. Air velocities across the burner assemblies are established by the use of profile plates. Manifold is located outside of air stream and shielded from atmospheric conditions by means of a protective compartment with hinged access. An observation port is located to provide view of pilot and main flame. Units are supplied with a wide range burner with a modulating turndown ratio of 25 to 1. Adjustable profile plates provided and sized to maintain the required velocity across the line burner. The operation of the burner is programmed through the flame safeguard with timed prepurge and flame sensing. Units are provided with a control compartment. All controls mounted within this compartment are wired to a numbered terminal strip. All wiring is color coded and in accordance with NEC. A circuit diagram of the approved electrical drawing is provided with the unit. All electrical components shall bear a recognized label. Unit controls consist of a spark ignition system with flame rod sensing of flame, high temperature limit switch set at 185 deg F [85 C] flame safeguard with alarm contacts, ignition transformer and high and low air proving differential switches. Unit also contains main fan starter and overloads, control circuit fuses and vents for outdoor units. Standard Gas Train The standard gas train consists of a main manual gas shutoff valve, two electric main gas shut-off valves, the Maxitrol modulating gas valve, a manual pilot gas shutoff valve, a manual pilot gas pressure regulator, a pilot gas valve, an orificed needle valve and an auxiliary gas valve. Motor -General All motors are provided as standard with a starter for external overload protection and control transformer. All motors have rigid base construction and ball bearings. Class A insulated up to and including 3 hp [2.24 kVV] models. Class B insulation on 5 hp [3.73 kW] and above models. Energy efficient TEFC Motor Energy efficient TEFC motors have rigid base construction and ball bearings. Class B insulation on all motors. Inlet Hood Inlet hood constructed of heavy gauge galvanized steel. Birdscreen is heavy gauge galvanized steel with 1" [25.4 mm] square openings. High Gas Pressure Gas Train - .5 - 5 psig High gas pressure gas train 1/2- 5 psig [3.4 - 34 kPa]. Units 825 MBH and less require an additional gas pressure regulator if inlet pressure exceeds 1/2 psig [3.4 kPa]. Units over 825 MBH and less than 3300 MBH require a high gas pressure switch if inlet pressure exceeds % psig [3.4 kPa]. Units with 3300 MBH and over require minimum inlet pressure of 1 psig [6.8 kPa]. Inlet pressure at the job must be specified. FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 4 of 11 Installed by Others ''Costco Tukwila, WA (MS Add) October 28, 2013 UV Flame Sensor UV flame sensor checks to make sure the pilot flame has ignited before gas is sent to the main burner. Operates by sensing the Tight of the pilot flame. Roof Curb Roof Curbs are fabricated of heavy gauge galvanized steel, neoprene gasket included. 12" [305 mm] high roof curbs ship disassembled. FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 5 of 11 Installed by Others Costco Tukwila, WA (MS Add) Unit Dimensions - Direct -Fired Gas Makeup Air Units (Outdoor) Item: Al Qty: 1 Tag(s): GHU-14 October 28, 2013 NOTES: To permit blower shaft replacement, the side opposite the controls should have clearance equal to the unit width. Minimum of 60" [1524mm] for serviceability clearance. Supply duct connection (by others) to be "pants -legged" from unit discharge. Unit shown assembled. May ship separated. 21" Wide X 33" High [533 mm X 838 mm] Access Door 33" Wide X 33" High [838 mm X 838 mm] Control Cabinet Access • Front of Unit RIGHT SIDE VIEW 3" Supply Air Opening 22 1/8" 16" 22 1/8" - - 7 7/8"---0. 21" Wide X33"High 533 mm X 838 mm] Access Door WEIGHTS Blower/Burner = 1300 lbs [590 kg] Inlet Hood = 210 lbs [95 kg] FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 6 of 11 Installed by Others X 'Costco Tukwila, WA (MS Add) Unit Dimensions - Direct -Fired Gas Makeup Air Units (Outdoor) Item: Al Qty: 1 Tag(s): GHU-14 October 28, 2013 SUPPLY AIR OPENING X UNIT 1,51/8 22 1/8" 16" 1 3/4 1"X4"NAILER SUPPLIED BY OTHERS NEOPRENE GASKET SUPPLIED ROOF CURB ROOF CURB DETAIL ROOF FLD = Furnished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 7 of 11 Installed by Others Costco Tukwila, WA (MS Add) Unit Dimensions - Direct -Fired Gas Makeup Air Units (Outdoor) • Item: Al Qty: 1 Tag(s): GHU-14 October 28, 2013 Inlet Hood for 115-118,215-218,220-222 Sizes FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 8 of 11 Installed by Others • 'Costco Tukwila, WA (MS Add) Field Wiring - Direct -Fired Gas Makeup Air Units (Outdoor) Item: Al Qty: 1 Tag(s): GHU-14 October 28, 2013 CAUTION PRECAUCION ATTENTION USE COPPER CONDUCTORS ONLY! N.UTILISER OUE DES CONDUCTEURS EN CUIVRE! IUTILICE UNICAMENTE CONDUCTORES DE COBRE! UNT TERMINALS ARE NOT DESIGNED TO ACCEPT LES BORNE5 OE LUNTE tic SONT PAS CONCUES LAS TERMINALES DE LA UNDAD NO ESTAN DISENADAS OTHER TYPES OF CONDUCTORS. POUR RECEVOIR DAUTRES TYPES DE CONDUCTEURS. PARA ACEPTAR OTROS TWOS DE CONDUCTORES. FAILURE TO 00 SO MAY CAUSE DAMAGE TO TWE L'UTIUSATON DE TWT AUTRE CO DUCTEUR PEUT 51 NO LO RACE. PUEDE OCASIONAR DANO AL EOUPO. EOUPMENT. ENDOMMAGER L'EOUIPEAENT. UNIT O MAIN DISCONNECT 0 SWITCH O C POWER SUPPLY 460/60/3 FIELD SUPPLIED JUMPER REQUIRED WHEN NO DAMPER IS USED (115 VOLT) ® WARNING ® AVERTISSEMENT ® ADVERTENCIA HAZARDOUS VOLTAGEI TENSON DANGEREUSEI IVOLTAIE PELGROS01 .EWMOAEiEEm _ G PROCEDURE3 BEFORE xa viumout.r. ET co EmuErtmwwrt as comotaknms DEO LOE CALCLOREE LA WIDE WWI wN EEiEURII '�T FAILURE MOO n. mnvE RUNT IN` `M kesones oe EL NO IN/L.11 POO. 'wTEMORLEME N CE/0110/1 MOM, INJURY PG1.lFE"iIILMO1 cea S..LAWMEN BLESSURES CRAM rowwT Emu O Emw.EMOnm FEWOOLES WMELLES FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 9 of 11 Installed by Others Costco Tukwila, WA (MS Add) Field Wiring - Direct -Fired Gas Makeup Air Units (Outdoor) Item: Al Qty: 1 Tag(s): GHU-14 NOTE 1; A) REMOTE MOUNTING BETWEEN ROOMSTAT AND UNIT CONTROLLER UP TO 500 FEET IS VIA FOUR CONDUCTOR SCHIELDED CABLE -18 AVG. B) 5 PIN PORT FOR COMMISSIONING AND MAINTENANCE. NOTE 2; A) POWER IS SUPPLIED BY THE MODULE INTERFACE CABLE. B) THE MODULE INTERFACE CABLE UTILIZES AN RJ45 CONNECTOR AND A CAT -5 CABLE. C) MAXIMUM DISTANACE THE MODULE CAN BE MOUNTED FROM THE UNIT IS 1,000 FT. October 28, 2013' MRT EXPERT CONTROL SYSTEM UNIT TERMINAL STRIP MAIN - DISCONNECT 0 SWITCH SEE NOTE 1 0 0 Ca POWER SUPPY 460/60/3 KEYPAD DISPLAY (24 VOLT) SEE NOTE 2 Q Q O O i O FIELD SUPPLIED JUMPER REQUIRED WHEN NO DAMPER IS USED. 0 O FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 10 of 11 Installed by Others • "Costco Tukwila, WA (MS Add) October 28, 2013 Field Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family - Direct -Fired Gas Makeup Air Units (Outdoor) Item Tag(s) Qty Description Model Number Al GHU-14 1 Direct -Fired Outdoor Unit DFOA218FNH Field Installed Option Description Part/Ordering Number High gas pressure regulator 1 - 5 psig (7 - 34 kPa) FLD = Fumished by Trane U.S. Inc. dba Trane / Equipment Submittal Page 11 of 11 Installed by Others • PERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-0231 PROJECT NAME: COSTCO WHOLESALE SITE ADDRESS: 400 COSTCO DR X Original Plan Submittal Response to Incomplete Letter # DATE: 12-16-13 Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: Building uivision Public Works n C V-1() Fire Prevention Structural n Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12-17-13 Complete Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 01-14-14 Not Approved (attach comments) DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 KEY MECH CO OF WASHINGTON kl Washington State Department of Labor & Industries i Page 1 of 2 KEY MECH CO OF WASHINGTON Owner or tradesperson HEISLER, ROBERT L Principals HEISLER, ROBERT L FRANK LEONARD LEE SANDAHL Doing business as KEY MECH CO OF WASHINGTON WA UBI No. 600 196 154 19430 68TH AVE S STE B KENT, WA98032 253-872-7392 KING, County Business type Corporation Governing persons License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. KEYMEW*240NZ Effective — expiration 08/09/1976 — 04/01/2015 Bond LIBERTY MUTUAL INS CO Bond account no. 023011682 Received by L&I 03/23/2009 Insurance Hartford Fire Ins Co Policy no. 52UENOE0154 Received by L&I 03/28/2013 Savings No savings accounts during the previous 6 year period. $12,000.00 Effective date 04/01/2009 $1,000,000.00 Effective date 03/31/2013 Expiration date 04/01/2014 httos://secure.lni.wa. gov/verify/Detail.aspx?UBI=600196154&amp;LIC=KEYMEW * 240NZ&amp;... 12/30/2013 50 1'-0" wr 1- o a II II ENGINEER: HVAC REMODEL 400 COSTCO DRIVE TUKWILA, WA. 98188 co 1 ,- N r M. GARCINI DATE: DRAWING REVISIONS SHEET NO: 81 DRAWING SUBMITTALS SUBMIT FOR PERMIT Ed ce 0 u- 1- 2 2 m co SUBMIT FOR CONSTRUCTION zd I W Q 0 II II ENGINEER: HVAC REMODEL 400 COSTCO DRIVE TUKWILA, WA. 98188 DRAWN: M. GARCINI DATE: DRAWING REVISIONS SHEET NO: 81 O z STING ISTING • LLS B: SEPARATE PERMIT REQUIRED FOR; 13 Me -antic! Q'Electdcat CPlumbhv C=as Pipn�g City of Tukwila BUILDING DIVISION REVISIONS shall benato the scope without prior approval of iia Building Division. s will require a new plan submittal de additional plan review fees: Li\_pre88\87022\87022029\COS-TUKWILA-S1-HVAC ROOF FRAMING PLAN-192-87022029,dwg, 12-11-13, 1158pn, Mariag, 192 RECEIVED CITY OF TUKWILA DEC 1 6 2013 PERMIT CENTER ROOF FRAMING PLAN NOTES: 1/16" =11-0" 1.) ALL ITEMS ARE EXISTING (E) UNLESS NOTED AS NEW (N). 2.) FIELD VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. NOTIFY ENW IF EXISTING DIMENSIONS AND EXISTING CONDITIONS ARE NOT AS SHOWN ON PLANS AND SECTIONS. REVIEWED FOR ;ODE COMPLIANCE =` APPROVED DEC 2 6 2013 City of Tukwila 4' BUILDING DIVISION —J cn p L11 UW Z CeZ en LU 0 C N a) O Z N 13)c c W 1.11 0) 5 c aim Vs c/) N Lo N N N E 51. zc 3 >~ani Q N12 In •Eo F -N a) N v CD 0 SHEET CONTENTS: ROOF FRAMING PLAN II II ENGINEER: HVAC REMODEL 400 COSTCO DRIVE TUKWILA, WA. 98188 JOB NO: 87022029 ENGINEER: W. CHEN DRAWN: M. GARCINI DATE: 11-25-13 SHEET NO: 81 Li\_pre88\87022\87022029\COS-TUKWILA-S2-HVAC FRAMING PLAN-GNOTES-SECTIONS-48-87022029,dwg, 12-11-13, 1158pm, marlag, 48 4x6 D.F. #2 P.T. 112"0 LAG SCREW @ EA. CORNER INTO EXISTING FRAMING BELOW (4" EMBED) PLAN NEW D.F. #2 4x6 EA. END EXISTING COLUMN LAG SCREW PER SECT. @ EA. 4X CROSS MEMBER INTO EXIST. GLB. NEW LAG SCREW PER SECT. @ EA. CORNER INTO 4X & EXIST. PURLIN EXISTING GLB. PURLINS @ 8'-0" oc EQ. NEW MECH. UNIT. WEIGHT & LOCATION PER MAIN ROOF PLAN EXTEND 6" PAST /-- EXISTING PURLIN, TYP. NEW D.F. #2 4x6 EA. SIDE EXISTING GLB GIRDER EQ. MECH. UNIT FRAMING PLAN NOTE: 1. LOCATE C.G. OF UNIT OVER GLB. GIRDER 2. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS & DIMENSIONS 3. THIS SECTION APPLIES TO ALL NEW UNITS SHOWN ON ROOF FRAMING PLAN. C.G. OF MECH. UNIT • SECTION 1/2"0 LAG SCREW @ EA. 4x INTO GLB. (EMBED 4") SIMPSON "HU46" HGRS. TYP. EXIST. GLB GRIDER EXIST. PIPE COL. EXIST. GLB PURLIN 3/4" = 1'-0" 1/4" = 1'-0" MECH. UNIT & MAX. WT. PER PLAN. LOCATE C.G. OVER GLB CNETER LINE. NOTE: ATTACHEMENT OF MECH. UNIT TO CURB BY OTHERS METAL CURB BY OTHERS ATTACH TO 4X W/10d COMM. @ 6" oc & 1/2" 0x4" LAG SCREW @ EA. CORNER EXIST. PLYWOOD ROOF SHEATHING GENERAL NOTE THE FOLLOWING NOTES APPLY UNLESS NOTED OTHERWISE - ASTM'S NOTED ARE TO BE LATEST EDITION 1. DESCRIPTION Building Name & Site Location - Costco Wholesale - Tukwila, WA 2. DESIGN CODE AND STANDARDS Applicable Code (Edition/Name) - 2009 International Building Code (IBC) Other documents referenced by these notes shall be the specific edition referenced by the building code specified above, or if not specified, shall be the latest edition. 3. DESIGN LOADS a. Roof Live Load b. Seismic c. Wind Load d. Dead loads e. Special Loads f. Load Combinations 25 psf Ss = 1.429, S1 = 0.489, I = 1.0, Site Class "D", SDS = 0.953, SD1 = 0.493, Seismic Design Category = "D". Basic wind speed 85 (mph). Exposure C. Importance factor 1.0. Collateral Toads were not included in uplift design Weight of structure. The following special Toads are to be considered: Mechanical equipment on roof. Sprinkler lines, canopy & other reactions as noted on structural drawings. All Code required load combinations are to be used in the building design. Column reactions from these load combinations are to be given to the foundation engineer. SPECIAL CONDITIONS CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND SHALL PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. ABBREVIATIONS ARCH. B. OR BOT. BTWN. BLDG C.I.P. CLR. CNTR. CON. CONT. CONTR. DIA. EA. EL. OR ELEV. E.N.W. OR ENW E.F. E.W. F.O.C. F.O.P. F.O.S. F.O.W FTG. H. OR HORIZ. ELS.S. I.F. INC. ARCHITECT BOTTOM BETWEEN BUILDING CAST IN PLACE CLEAR CENTER CONCRETE CONTINUOUS CONTRACTOR DIAMETER EACH ELEVATION ENGINEERS NORTHWEST EACH FACE EACH WAY FACE OF CONCRETE FACE OF PLYWOOD FACE OF STUD FACE OF WALL FOOTING HORIZONTAL HOLLOW STRUCTURAL SECTION INSIDE FACE INCLUDING KB L.L.H. L.L.V. M.A.S. M.B.S. N.F. N.T.S. oc O.F. OPNG. O.T.O. PNL. REINF. R.O. SW SIM. SYMM. T. T.O.F. T.S. TYP. U.N.O. V. OR VERT. V.I.F. V.O.F. w/ KWIK BOLT LONG LEG HORIZONTAL LONG LEG VERTICAL MASONRY (CLAY OR CMU) METAL BLDG SUPPLIER NEAR FACE NOT TO SCALE ON CENTER OUTSIDE FACE OPENING OUT TO OUT PANEL REINFORCING ROUGH OPENING SHEARWALL SIMILAR SYMMETRICAL TOP TOP OF FOOTING TUBE STEEL TYPICAL AT ALL SIMILAR PLACES UNLESS NOTED OTHERWISE VERTICAL VERTICAL INSIDE FACE VERTICAL OUTSIDE FACE WITH 3- 0231 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 262013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1 6 2013 PERMIT CENTER w 17, o dIH -1 HVAC REMODEL 400 COSTCO DRIVE TUKWILA, WA. 98188 c+3 A M.T.G. DATE: DRAWING REVISIONS NEW D.F. #2 4x6 EA. SIDE EXISTING GLB GIRDER EQ. MECH. UNIT FRAMING PLAN NOTE: 1. LOCATE C.G. OF UNIT OVER GLB. GIRDER 2. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS & DIMENSIONS 3. THIS SECTION APPLIES TO ALL NEW UNITS SHOWN ON ROOF FRAMING PLAN. C.G. OF MECH. UNIT • SECTION 1/2"0 LAG SCREW @ EA. 4x INTO GLB. (EMBED 4") SIMPSON "HU46" HGRS. TYP. EXIST. GLB GRIDER EXIST. PIPE COL. EXIST. GLB PURLIN 3/4" = 1'-0" 1/4" = 1'-0" MECH. UNIT & MAX. WT. PER PLAN. LOCATE C.G. OVER GLB CNETER LINE. NOTE: ATTACHEMENT OF MECH. UNIT TO CURB BY OTHERS METAL CURB BY OTHERS ATTACH TO 4X W/10d COMM. @ 6" oc & 1/2" 0x4" LAG SCREW @ EA. CORNER EXIST. PLYWOOD ROOF SHEATHING GENERAL NOTE THE FOLLOWING NOTES APPLY UNLESS NOTED OTHERWISE - ASTM'S NOTED ARE TO BE LATEST EDITION 1. DESCRIPTION Building Name & Site Location - Costco Wholesale - Tukwila, WA 2. DESIGN CODE AND STANDARDS Applicable Code (Edition/Name) - 2009 International Building Code (IBC) Other documents referenced by these notes shall be the specific edition referenced by the building code specified above, or if not specified, shall be the latest edition. 3. DESIGN LOADS a. Roof Live Load b. Seismic c. Wind Load d. Dead loads e. Special Loads f. Load Combinations 25 psf Ss = 1.429, S1 = 0.489, I = 1.0, Site Class "D", SDS = 0.953, SD1 = 0.493, Seismic Design Category = "D". Basic wind speed 85 (mph). Exposure C. Importance factor 1.0. Collateral Toads were not included in uplift design Weight of structure. The following special Toads are to be considered: Mechanical equipment on roof. Sprinkler lines, canopy & other reactions as noted on structural drawings. All Code required load combinations are to be used in the building design. Column reactions from these load combinations are to be given to the foundation engineer. SPECIAL CONDITIONS CONTRACTOR SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND SHALL PROVIDE ADEQUATE SHORING AND BRACING OF ALL STRUCTURAL MEMBERS DURING CONSTRUCTION. CONTRACTOR SHALL NOTIFY ENGINEER OF ALL FIELD CHANGES PRIOR TO INSTALLATION. ABBREVIATIONS ARCH. B. OR BOT. BTWN. BLDG C.I.P. CLR. CNTR. CON. CONT. CONTR. DIA. EA. EL. OR ELEV. E.N.W. OR ENW E.F. E.W. F.O.C. F.O.P. F.O.S. F.O.W FTG. H. OR HORIZ. ELS.S. I.F. INC. ARCHITECT BOTTOM BETWEEN BUILDING CAST IN PLACE CLEAR CENTER CONCRETE CONTINUOUS CONTRACTOR DIAMETER EACH ELEVATION ENGINEERS NORTHWEST EACH FACE EACH WAY FACE OF CONCRETE FACE OF PLYWOOD FACE OF STUD FACE OF WALL FOOTING HORIZONTAL HOLLOW STRUCTURAL SECTION INSIDE FACE INCLUDING KB L.L.H. L.L.V. M.A.S. M.B.S. N.F. N.T.S. oc O.F. OPNG. O.T.O. PNL. REINF. R.O. SW SIM. SYMM. T. T.O.F. T.S. TYP. U.N.O. V. OR VERT. V.I.F. V.O.F. w/ KWIK BOLT LONG LEG HORIZONTAL LONG LEG VERTICAL MASONRY (CLAY OR CMU) METAL BLDG SUPPLIER NEAR FACE NOT TO SCALE ON CENTER OUTSIDE FACE OPENING OUT TO OUT PANEL REINFORCING ROUGH OPENING SHEARWALL SIMILAR SYMMETRICAL TOP TOP OF FOOTING TUBE STEEL TYPICAL AT ALL SIMILAR PLACES UNLESS NOTED OTHERWISE VERTICAL VERTICAL INSIDE FACE VERTICAL OUTSIDE FACE WITH 3- 0231 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 262013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1 6 2013 PERMIT CENTER w 17, o dIH ENGINEER: HVAC REMODEL 400 COSTCO DRIVE TUKWILA, WA. 98188 c+3 A M.T.G. DATE: DRAWING REVISIONS SHEET NO: S2 DRAWING SUBMITTALS SUBMIT FOR PERMIT SUBMIT FOR BID SUBMIT FOR CONSTRUCTION o z z 1 1-- 0 dIH ENGINEER: HVAC REMODEL 400 COSTCO DRIVE TUKWILA, WA. 98188 DRAWN: M.T.G. DATE: DRAWING REVISIONS SHEET NO: S2 O z I—uj LU 0. Z Ce Z C f/) LLI U) 3 t 0 z N W 5 co co co 03 I co N N N aa� E .io. u z�� e Q a) as p. c c o F ~ N 4 ) N v rna SHEET MECH UNIT FRAMING PLAN, SECTION & GENERAL NOTES CONTENTS: dIH ENGINEER: HVAC REMODEL 400 COSTCO DRIVE TUKWILA, WA. 98188 JOB NO: 87022029 ENGINEER: W. CHEN DRAWN: M.T.G. DATE: 11-25-13 SHEET NO: S2 MS\171M-1 XX NM uuu NM FIELD V RIFY OPERATION OF EXI TING BACKDRAFT DAMPER . REPLACE AS NECESSARY. 1 1 1 1 SEE DETA L FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. FIELD VERIFY OPE TION OF EXISTING BACKD AFT DAMPERS. REPLACE AS ECE SSARY a- f DIFFUSER DIFFUSER TO BE MOUNTED AS CLOSE TO COLUMN AS POSSIBLE. UNIT CENTER L OF GRAVITY OF TO BE ABOVE COLUMN. —M- 1-1/2" GAS (1650 MBH) CONNECT NEW 1-1/2" GAS TO EXISTING 1-1/2" GAS APPROX. HERE. FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. • . f IL-- PRESSURE DROP PSI TO 1.5 MAX DEVELOPED LENGTH (FEET) 300 o I 1/2" �f 1,044 1" 1,966 L._. 4,036 1-1/2" 6,048 2" 11,647 2-1/2" 18,564 3" 32,818 FIELD V RIFY OPERATION OF EXI TING BACKDRAFT DAMPER . REPLACE AS NECESSARY. 1 1 1 1 SEE DETA L FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. FIELD VERIFY OPE TION OF EXISTING BACKD AFT DAMPERS. REPLACE AS ECE SSARY a- f DIFFUSER DIFFUSER TO BE MOUNTED AS CLOSE TO COLUMN AS POSSIBLE. UNIT CENTER L OF GRAVITY OF TO BE ABOVE COLUMN. —M- 1-1/2" GAS (1650 MBH) CONNECT NEW 1-1/2" GAS TO EXISTING 1-1/2" GAS APPROX. HERE. FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. • . f .I. • . • • . • ERIFY OPERA I • OF EXISTING BACKD'A' DAMPERS. REPLACE 'S ARY. 0— FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. 1 1 F ELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. N111111ON1111111111I=II•11111111•11111111111111111II��I FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. 1 L (E)1-1/2" 0 5 PSI G G G 1 FIELD VERT EXISTING INDEF ENDENT 1-1/2" GAS LINE ® 5 PSI PREVIOUSLY SERVING COFFEE RO STER HAS BEEN CAPPED AND HAS NO OTHER CONNECTIONS. 0 PRIOR TO INSTALLATION . VERIFY EXISTING DUCT DROPS ARE FREE AND CLEAR OF SPRINKLER PIPING, STRUCTURAL MEMBERS, ETC. 2. PROVIDE DIMENSIONAL DATA TO COIL TECH FOR EACH DUCT DROP. FOR FABRICATION ALLOW 4 WEEK LEAD TIME FOR FABRICATION AND SHIPPING. 3. DIFFUSER REPLACEMENT OPTION. IF INTERFERENCE OR OTHER CIRCUMSTANCES PROHIBIT EASY REPLACEMENT OF THE ENTIRE DUCT PACKAGE PROVIDE EXISTING DUCT SIZE INFO FOR ATTACHMENT OF NEW DIFFUSER TO EXISTING SUPPLY DUCT. 4. VERIFY EXISTING UNIT NUMBER AND MODEL IN SCHEDULE. 5. VERIFY ANY STRUCTURAL PLANS MATCH MECHANICAL PLANS PLANS. MAIN MECH 8c ELEC PLAN SCALE: 1/16" = 1'-0" GENERAL MECHANICAL NOTES THE FOLLOWING NOTES APPLY TO ENTIRE PLAN AS APPLICABLE. 1. M.C. SHALL ASSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH CALLOUTS ON PLAN ON THE INSIDE & OUT OF THE BUILDING. THIS INCLUDES TRANE UNITS & EXHAUST FANS. LABELS SHOULD BE IN 6" BLOCK LETTERING IN BLACK COLOR AND LOCATED WHERE EASILY VISIBLE FROM THE ROOF HATCH. 2. MAINTAIN A MINIMUM OF 10'-0" BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE. 3. COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT. NO DUCTWORK WILL BE ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION EQUIPMENT OR PANELS. 4. INSTALLATION INSTRUCTIONS FOR ALL LISTED EQUIPMENT SHALL BE PROVIDED TO THE FIELD INSPECTOR AT TIME OF INSPECTION. 5. DIMENSIONS ARE TO COLUMN LINES. 6. APPLICABLE BUILDING CODE IBC 2012 APPLICABLE MECHANICAL CODE: IMC 2012 APPLICABLE ENERGY CODE: 2012 WSEC 7. PROVIDE TIE DOWN FOR ALL FLUES & VENTS OF 3' OR TALLER. 8. RUN ALL SUPPLY, RETURN AND EXHAUST DUCTS AND FLUES BETWEEN THE ROOF AND CEILING SPACE STRAIGHT WITH INTERNAL INSULATION. NO ANGLES OR OFFSETS. CONTACT ARCHITECT TO RESOLVE ANY CONFLICTS WITH STRUCTURE. 9. ALL CONDENSATE PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. MECHANICAL PLAN NOTES SEE BUBBLE ON PLAN FOR SPECIFIC REFERENCE. INSTALL NEW HEATING UNIT. MC TO LOCATE ROOF PENETRATIONS AND ROOF CURB FOR M.B.S. AND/OR G.C. PENETRATIONS SHALL BE SUCH THAT SUPPLY, RETURN AND/OR EXHAUST DUCT DROPS CAN EXTEND STRAIGHT DOWN TO CEILING SPACE OR DIFFUSER PACKAGE. RELOCATION OF ANY UNIT FROM WHERE SHOWN ON PLAN SHALL BE APPROVED BY ARCHITECT PRIOR TO UNIT INSTALLATION. COORDINATE EQUIPMENT LOCATION WITH LIGHTS, BLDG. STRUCTURE, PIPING, SWAY BRACING AND SKYLIGHTS. SEE ARCHITECTURAL, STRUCTURAL AND ELECTRICAL PLANS. LOCATE SALES FLOOR AC UNITS BETWEEN RACKS. CENTER SUPPLY DUCT DROP OPENING BETWEEN JOISTS. REQUIRED CLEARANCE FOR ROOFTOP UNIT IS SHOWN. 0 lol 0 r x ■ x . J xj GAS SIZE CHART PRESSURE PSI 5 PRESSURE DROP PSI TO 1.5 MAX DEVELOPED LENGTH (FEET) 300 o I 1/2" 499 3/4" 1,044 1" 1,966 L._. 4,036 .I. • . • • . • ERIFY OPERA I • OF EXISTING BACKD'A' DAMPERS. REPLACE 'S ARY. 0— FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. 1 1 F ELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. N111111ON1111111111I=II•11111111•11111111111111111II��I FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS NECESSARY. 1 L (E)1-1/2" 0 5 PSI G G G 1 FIELD VERT EXISTING INDEF ENDENT 1-1/2" GAS LINE ® 5 PSI PREVIOUSLY SERVING COFFEE RO STER HAS BEEN CAPPED AND HAS NO OTHER CONNECTIONS. 0 PRIOR TO INSTALLATION . VERIFY EXISTING DUCT DROPS ARE FREE AND CLEAR OF SPRINKLER PIPING, STRUCTURAL MEMBERS, ETC. 2. PROVIDE DIMENSIONAL DATA TO COIL TECH FOR EACH DUCT DROP. FOR FABRICATION ALLOW 4 WEEK LEAD TIME FOR FABRICATION AND SHIPPING. 3. DIFFUSER REPLACEMENT OPTION. IF INTERFERENCE OR OTHER CIRCUMSTANCES PROHIBIT EASY REPLACEMENT OF THE ENTIRE DUCT PACKAGE PROVIDE EXISTING DUCT SIZE INFO FOR ATTACHMENT OF NEW DIFFUSER TO EXISTING SUPPLY DUCT. 4. VERIFY EXISTING UNIT NUMBER AND MODEL IN SCHEDULE. 5. VERIFY ANY STRUCTURAL PLANS MATCH MECHANICAL PLANS PLANS. MAIN MECH 8c ELEC PLAN SCALE: 1/16" = 1'-0" GENERAL MECHANICAL NOTES THE FOLLOWING NOTES APPLY TO ENTIRE PLAN AS APPLICABLE. 1. M.C. SHALL ASSURE ALL ROOF TOP EQUIPMENT IS LABELED CORRECTLY AND MATCH CALLOUTS ON PLAN ON THE INSIDE & OUT OF THE BUILDING. THIS INCLUDES TRANE UNITS & EXHAUST FANS. LABELS SHOULD BE IN 6" BLOCK LETTERING IN BLACK COLOR AND LOCATED WHERE EASILY VISIBLE FROM THE ROOF HATCH. 2. MAINTAIN A MINIMUM OF 10'-0" BETWEEN EXHAUST OUTLET AND UNIT FRESH AIR INTAKE. 3. COORDINATE ALL MECHANICAL DUCTWORK LOCATIONS WITH ELECTRICAL EQUIPMENT. NO DUCTWORK WILL BE ALLOWED TO RUN OVER THE TOP OF ELECTRICAL DISTRIBUTION EQUIPMENT OR PANELS. 4. INSTALLATION INSTRUCTIONS FOR ALL LISTED EQUIPMENT SHALL BE PROVIDED TO THE FIELD INSPECTOR AT TIME OF INSPECTION. 5. DIMENSIONS ARE TO COLUMN LINES. 6. APPLICABLE BUILDING CODE IBC 2012 APPLICABLE MECHANICAL CODE: IMC 2012 APPLICABLE ENERGY CODE: 2012 WSEC 7. PROVIDE TIE DOWN FOR ALL FLUES & VENTS OF 3' OR TALLER. 8. RUN ALL SUPPLY, RETURN AND EXHAUST DUCTS AND FLUES BETWEEN THE ROOF AND CEILING SPACE STRAIGHT WITH INTERNAL INSULATION. NO ANGLES OR OFFSETS. CONTACT ARCHITECT TO RESOLVE ANY CONFLICTS WITH STRUCTURE. 9. ALL CONDENSATE PIPING TO BE SLOPED AT 2% MINIMUM UNLESS OTHERWISE NOTED. MECHANICAL PLAN NOTES SEE BUBBLE ON PLAN FOR SPECIFIC REFERENCE. INSTALL NEW HEATING UNIT. MC TO LOCATE ROOF PENETRATIONS AND ROOF CURB FOR M.B.S. AND/OR G.C. PENETRATIONS SHALL BE SUCH THAT SUPPLY, RETURN AND/OR EXHAUST DUCT DROPS CAN EXTEND STRAIGHT DOWN TO CEILING SPACE OR DIFFUSER PACKAGE. RELOCATION OF ANY UNIT FROM WHERE SHOWN ON PLAN SHALL BE APPROVED BY ARCHITECT PRIOR TO UNIT INSTALLATION. COORDINATE EQUIPMENT LOCATION WITH LIGHTS, BLDG. STRUCTURE, PIPING, SWAY BRACING AND SKYLIGHTS. SEE ARCHITECTURAL, STRUCTURAL AND ELECTRICAL PLANS. LOCATE SALES FLOOR AC UNITS BETWEEN RACKS. CENTER SUPPLY DUCT DROP OPENING BETWEEN JOISTS. REQUIRED CLEARANCE FOR ROOFTOP UNIT IS SHOWN. 0 lol 0 r x ■ x . J xj GAS SIZE CHART PRESSURE PSI 5 PRESSURE DROP PSI TO 1.5 MAX DEVELOPED LENGTH (FEET) 300 PIPE SIZE( UPC) MAX LOAD (MBH) 1/2" 499 3/4" 1,044 1" 1,966 1-1/4" 4,036 1-1/2" 6,048 2" 11,647 2-1/2" 18,564 3" 32,818 4" 66,939 6" 196,092 8" 402,893 PROVIDE ONE OF FOLLOWING REGULATORS AT EACH PIECE OF EQUIPMENT UP TO 400 MBH SENSUS MODEL - 496 PIPE SIZE - 3/4" OR 1" ORIFICE - 3/8" SPRING - GREEN MAXITROL MODEL - 325-5AL 600 PIPE SIZE - 3/4" OR 1" 0.. 0 w U w U v7 GAS SIZE CHART PRESSURE IN WC 7 PRESSURE DROP 0.5 MAX DEVELOPED LENGTH (FEET) 100 PIPE SIZE ( UPC) MAX LOAD (MBH) 1/2" 47 3/4" 98 1" 185 1-1 /4" 380 1-1/2" 570 2" 1,098 2-1/2" 1,750 3" 3,093 4" 6,309 6" 18,483 8" 37,976 Nj 0 N M 0 O J FIELD VERIFY OPERATION OF EXISTING BACKDRAFT DAMPERS. REPLACE AS— NECESSARY. 0 0 0 x— t1I3O-3J REVIEWED FOR CODE COMPLIANCE t g., APPROVED DEC 2 6 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 162013 PERMIT CENTER HVAC LEGEID f Fa w i k —C— lir v 0 CONT. TYP. CFM DB DG WB MBH ESP RA SA CO VD MBS M.0 G.0 SUPPLY DUCT RETURN DUCT SUPPLY DUCT RETURN DUCT UP UP DOWN DOWN CONDENSATE DRAIN AIR CONDITIONER #1 THERMOSTAT THERMOSTAT (W/LOCKING COVER) SENSOR CONTINUATION TYPICAL CUBIC FEET PER MINUTE DRY BULB TEMPERATURE DOOR GRILLE WET BULB TEMPERATURE 1,000 BRITISH THERMAL UNITS/HR. EXTERNAL STATIC PRESSURE RETURN AIR SUPPLY AIR CLEAN OUT VOLUME DAMPER METAL BUILDING SUPPLIER MECHANICAL CONTRACTOR GENERAL CONTRACTOR z W AND HVAC J 0 z Z oLL wo Er. O I- U Z w oz W0 (f)w w� m� a 0 0 zaa.. w w U � of �o LL oQQ I-0_ aZ z o Q 1 PM, TLeitch MS\1 71 M-2.dwg, ECONOMIZER HOOD---- ROOF OODROOF CURB— ROOF —Z SUPPLY DUCT DIFFUSER PACKAGE INSTALLED BY M.C. NOTE: (1) SEE SCHEDULE FOR ITEMS PROVIDED BY OWNER. (2) CENTER SUPPLY DUCT FOR UNIT BETWEEN JOISTS. ROOF MOUNTED AC UNIT DETAIL L PROVIDE SEISMIC BRACING PER LOCAL CODE CURB AND COUNTER FLASHING PER ARCH. PROVIDE HOLD DOWN CABLE PER DETAIL SEE FIRE PROTECTION DRAWINGS FOR SMOKE DETECTOR REQUIREMENTS. PROVIDED BY FIRE ALARM CONTRACTOR INSTALLED BY M.C. (SEE SPEC FOR FIRE ALARM CONTRACTOR RESPONSIBILITY) SCALE: NONE NOTE: M.0 TO COORDINATE DROP SIZES PRIOR TO ORDERING. M.C. RESPONSIBLE FOR ALL FIELD MODIFICATION FROM INCORRECT DIMENSIONS DURING ORDERING. FOR INSTALLATION INSTRUCTIONS, CONTACT COIL TECH. (509)891-2751 NOTE: FOR 3 -WAY PACKAGE, ROTATE VANES TO CLOSE OFF BACK SIDE OF DRUM LOUVERS TO MATCH AIR FLOW DIRECTIONS PER PLAN. GHU UNITS 3 -WAY 17,000 CFM UNIT ROOF TOP MECHANICAL UNIT HOLD DOWNS (WIND SPEED EXPOSURE PER STRUCTURAL) OPERATING WEIGHT(LBS) WIND SPEED EXPOSURE 85 M.P.H. 90 M.P.H. 100 M.P.H. 110 M.P.H. 120 M.P.H. 130 M.P.H. 140 M.P.H. 150 M.P.H. 1.5,-2 TON 425-500# LONG SIDE 2 2 2 2 2 2 2 3 SHORT SIDE 2 2 2 2 2 2 2 2 3,-5 TON 625-1200# LONG SIDE 2 2 2 2 3 4 5 6 SHORT SIDE 2 2 2 2 2 2 2 2 6,-10 TON 915-1480# LONG SIDE 2 2 2 3 4 5 6 7 SHORT SIDE 2 2 2 2 2 2 2 2 12.5 TON 1550-1875# LONG SIDE 3 3 3 3 4 5 6 7 SHORT SIDE 2 2 2 2 2 2 2 2 15,-25 TON 2220-3500# LONG SIDE 3 3 3 4 5 6 8 10 SHORT SIDE 2 2 2 2 2 2 2 2 ROOF TOP AC UNIT DO NOT BLOCK ACCESS PANELS NEOPRENE GASKET BY M.C. RIGID INSULATION ROOF DECK III .Im]! EEEE EBB EEEE BEE EEEE EEEE BEE BRE Kali EEEE EEEE EEEE EEEE BEE EEEE 340P500 3/16" SS CLEVIS AIRCRAFT CABLE ss 7" NO. 12 SELF DRILLING SCREW (TYP. OF 2) HOLD DOWN CABLE SUPPLIED BY OWNER, INSTALLED BY M.C. 14 GA. ROOF CURB. SEE SCHEDULE FOR PROVIDER TRANE AC UNIT HOLD DOWN CABLE SCALE: NONE AC DIFFUSER CONFIGURATION & DIFFUSER PACKAGE SCALE: NONE TITUS 30/15 DRUM LOUVER (TYP. OF 8) TES PORT 10 ALL MINIMUM E DIAMETERS OUTLET. FROM AS TO AC UNIT. GAS SHUT OFF PROVIDED BY MC GAS PIPING ASSEMBLY GAS SUPPLY FROM BLDG. AC GAS PIPING DIAGRAM SCALE: NONE HVAC EQUIPMENT SCHEDULE-S.O.I.C. SYMBOL ITEM SERVES MFR/# DESCRIPTION ELECT. WEIGHT REFERENCE REMARKS NOTES GHU-14 GAS HEATING MAIN TRANE DIRECT FIRED GAS HEATING UNIT 460V/30 1300#:UNIT PLAN M-1 100% 0/A (1) (2) (3) UNIT SALES DFOA218FN HE1AGKO3A 1650 MBH INPUT, 1518 MBH OUTPUT, 100% AFUE 25' EDB, 80' TEMP RISE 0 17,000 CFM & 1.0" ESP 15 HP 200#CURB 800#DIFF 6/M-2 UNIT TO BE U.L. LISTED (4) (5) (6) 2300#:TOTAL 29/M-2 GENERAL NOTES: - ALL EQUIPMENT FURNISHED BY COSTCO, INSTALLED BY M.C. CONTACT COSTCO PURCHASING DEPT. TO COORDINATE DELIVERY TIME © FAX (425)313-6770 - AC UNITS PROVIDED WITH COMM INTERFACE CONTROLLED BY MANUFACTURER PROVIDED T'STAT. - AC UNITS TO BE SUPPLIED WITH ECONOMIZER, BAROMETRIC RELIEF, THROW -AWAY FILTERS, AND HINGED ACCESS DOORS. - AC UNITS TO BE SUPPLIED WITH THROUGH THE BASE ELECTRICAL WITH CIRCUIT BREAKER, 120V/15AMP CONVENIENCE OUTLET, AND THROUGH THE BASE GAS PIPING CONNECTION UNLESS OTHERWISE NOTED. - CONTRACTOR TO INSTALL ALL ITEMS LISTED IN EQUIPMENT SUBMITTAL AS FIELD INSTALLED. INSTALL PER MANUFACTURERS INSTALLATION AND OPERATION MANUAL. (1) ROOF CURBS BY G.C. (2) HVAC SUPPLY/RETURN DUCT DROP S.O.I.C. (3) OUTSIDE AIR CONTROLLED BY CO2 SENSOR TO MAINTAIN MAXIMUM 1000 PPM CO2 AND MAINTAIN THE BUILDING AT A POSITIVE STATIC PRESSURE (4) UNITS TO BE SUPPLIED WITH VARIABLE FREQUENCY DRIVE. (5) CENTER OF GRAVITY OF UNIT TO BE DIRECTLY ABOVE COLUMN. (6) CONTROLLED BY BAROMETRIC PRESSURE TO PROVIDE MAKE UP AIR TO BUILDING EXHAUST SYSTEMS. (7) NOT USED (8) NOT USED (9) NOT USED 29 43O23 1 REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 6 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1 6 2013 PERMIT CENTER SCHEDULE AND 0 r) O REVISION DATE: DECEMBER 0 (N1 O ISSUE DATE: SEPTEMBER ARCHITECT REFERENCE NO: J O Z Z O W W_ o d O U Z W IX V) OZ O 0 U L.LJw W mQ >� a� MO o- w H 0 O 1_ c No 2 I- oQ I- a IX aZ zo 0 PROJECT NO:12-171 ELECTRICAL DEMOLITION & REMODEL GENERAL NOTES FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID. REMOVAL OF EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND REMOVING OF THE EXISTING CONDUITS AND WIRING BACK TO THE NEXT ACTIVE OUTLET OR SOURCE. PROVIDE MATCHING BLANK COVER PLATE AS REQUIRED. REMOVE OR ABANDON ALL UNUSED UNDERGROUND, UNDER FLOOR RACEWAYS. REMOVE WIRES. REMOVE ALL UNUSED SURFACE RACEWAYS. RELOCATE EXISTING ITEMS SHALL INCLUDE DISCONNECTING AND EXTENDING EXISTING CONDUITS AND WIRING TO NEW LOCATION, PROVIDE NEW CONNECTION AS REQUIRED. PROVIDE CUTTING, PATCHING FOR ALL RELATED ELECTRICAL WORK AS REQUIRED. INFORMATION ON THE EXISTING INSTALLATION HAS BEEN OBTAINED FROM THE BEST SOURCE AVAILABLE BUT CANNOT BE GUARANTEED ACCURATE IN ALL RESPECTS. PRIOR TO BID, IT IS THE CONTRACTORS'S RESPONSIBILITY TO VISIT THE SITE. VERIFY ALL SUCH INFORMATION AND THOROUGHLY FAMILIARIZE THEMSELVES WITH THE EXISTING CONDITIONS. ALL WORKS SHALL BE PERFORMED TO CHANGE THE EXISTING ELECTRICAL INSTALLATION AS SHOWN. INCLUDE AS PART OF THE CONTRACT ALL RELATED WORKS REQUIRED TO OBTAIN THE INDICATED RESULTS. ALL EXISTING WIRING, CONDUITS, JUNCTION BOXES AND ALL OTHER ELECTRICAL EQUIPMENT AND DEVICES IN THE AREAS AFFECTED BY THE REMODEL SHALL BE REMOVED AND RELOCATED AS REQUIRED. EXTEND ALL CONDUITS AND WIRING. ALL WORKS ARE TO BE DONE SO AS NOT TO INTERFERE WITH THE WAREHOUSE'S NORMAL OPERATION. ALL WORKS ARE TO BE COORDINATED AND SCHEDULED AS APPROVED BY THE WAREHOUSE MANAGER FOR ELECTRICAL SHUTDOWN, CONTINUITY OF SERVICE, ETC. COORDINATE AND SCHEDULE WITH OWNER FOR ANY EXISTING ELECTRICAL SERVICE SHUTDOWN, PROVIDE TEMPORARY POWER TO MAINTAIN EXISTING ELECTRICAL SYSTEM FOR WAREHOUSE'S NORMAL OPERATION AS REQUIRED. TEMPORARY POWER SOURCES INCLUDE GENERATOR SET, POWER COMPANY'S TEMPORARY SERVICE HOOKUP, ETC. E.C. TO PROVIDE NEW TYPED INDEX FOR EXISTING PANELS AFFECTED BY THIS REMODEL. TURN 'OFF' ALL SPARE BREAKERS AND PROVIDE 'SPARE' LABEL ELECTRICAL LEGEND g BRANCH PANEL N EXISTING PANEL ,---, CONDUIT IN CEILING OR WALL, 1/2" MIN. Pte—. HOME RUN TO PANEL WITH CIRCUIT NUMBER, SLASHES INDICATE NUMBER OF CONDUCTORS #81"c INDICATES WIRES AND CONDUIT OTHER THAN #12,1/2"C C — METALLIC CONDUIT ® DUPLEX RECEPTACLE GFI GROUND FAULT CIRCUIT INTERRUPTER WP WATERPROOF m' FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER 0' NON—FUSED DISCONNECT, COORDINATE W/EQUIPMENT SUPPLIER TYP. TYPICAL Li L2 L3 400A CRD) OPTIONAL POWERED GFCI 401ACBL) 400A(RD) 401A (BL) CRD) CBL) W3 CBK) COMPRESSOR CONTACTOR 0 UNIT DISCONNECT / RECEPTACLE \DISCONNECT 0 402A(RD) FU12 404C(RD) 403ACBL) 0 FU13 405C(BL) CRD) o o CBR) NEUT -wr (WH) 120V (BK) SERVICE RECEPTACLE TRANSFORMER 410ACWH) 411ACBK) SERVICE PPF25,1PPF25,2 RECEPTACLEA ^ PPM25,1 'PM25,2 PLUG 412ACWH) _ 413ACBK) (GR) SERVICE 15 AMP RECEPTACLE 120V - GFCI UNIT LDIS ON— ROO WITCH AA/C DUNIONVENIENCE OUTLET — U AC FACTORY INSTALLED DISCONNECT AND CONVENIENCE OUTLET WIRING DIAGRAM NO SCALE E— 2 EXISTING MDP EXISTING 2500 A CU BUS, 480 VOLT, 3 b, 4W EXISTING 400A/3P 400AF (LPJ) EXISTING 400A/3P 400AF (LPJ) EXISTING PANEL H3 EXISTING cJ EXISTING FEEDER FEEDER EXISTING PANEL PP1 PARTIAL ONE LINE DIAGRAM NO SCALE PANEL: H3 480 / 277 VOLTS 3 PHASE 4 WIRE 400 A CU BUS M.L.O. A.I.C. MIN. EXISTING FEED SURFACE MOUNT CIRCUIT USE PHASE A (KVA) B C ' BKR. CKT.CKT. NO. NO. BKR. PHASE A (KVA) B C CIRCUIT USE 1 2 SPARE 15/3 3 4 15/3 SPARE 5 6 7 8 SPARE 30/3 9 10 15/3 SPARE 11 12 13 14 SPARE 20/3 15 16 50/3 SPARE 17 18 19 20 SPARE 50/3 21 22 15/3 SPARE 23 24 25 26 SPARE 15/3 27 28 20/3 SPARE 29 30 31 32 SPARE 50/3 33 34 40/3 SPARE 35 36 37 38 SPARE 50/3 39 40 110/3 SPARE 41 42 SECTION 2 OF 2 2.16 43 44 AC -3 2.16 15/3 45 46 110/3 SPARE 2.16 47 48 13.54 49 50 5.57 AC -8 13.54 70/3 51 52 40/3 5.57 GHU-14 * 13.54 53 54 5.57 11.45 55 56 AC -9 11.45 60/3 57 58 30/3 SPARE 11.45 59 60 61 62 SPARE 20/3 63 64 30/3 SPARE 65 66 67 68 SPARE 20/3 69 70 20/3 SPARE 71 72 73 74 SPARE 20/3 75 76 15/3 SPARE 77 78 SPACE 79 80 SPACE SPACE 81 82 SPACE SPACE 83 84 SPACE TOTAL PHASE A (KVA) TOTAL PHASE B (KVA) TOTAL PHASE C (KVA) 27.15 27.15 27.15 32.72 KVA 32.72 KVA 32.72 KVA 5.57 5.57 5.57 TOTAL CONNECTED LOAD 98.16 KVA 118 A * NEW LOAD. E.C. TO PROVIDE NEW BREAKER AS REQUIRED. E.C. TO FIELD VERIFY AVAILABLE SPACE/ SPARE PRIOR TO BID Mt?'O)3l ' REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 6 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 1 6 2013 PERMIT CENTER c 0 z Q 0 w U w U z 2 M O N REVISION DATE: DECEMBER 0 N 0 ISSUE DATE: SEPTEMBER ARCHITECT REFERENCE NO: 1:21- F.7-1 W 1-4 J z z w_ ow d OF - U z w G✓ 0 z o w w� m E I-1 Q I � o z ✓ w U c) N LJ- F- 0Ix F- d a ▪ z Q zo z 1171 SCHEDULES, z 0 11 a PROJECT NO:12-171 MS\1 71 E-2.dwg, 4 0 0 0 0 0 0 ■N ■ • ■ HHH PANEL P13 ■- ■ ■■■■■■■■■■■■■.■.■ 1111■...■■■■■■■■■■■ 1 1 1 04111111 ■1111■.■1111■■ ■■■■■■ 1111■■■■■.■...1111■■■ MIN MEM [rld • AN NOTES: Q NOT USED. O GHU UNIT IS LOCATED ON ROOF. VERIFY EXACT LOCATION WITH M.C. BEFORE ROUGH -IN INSTALLATION. HVAC POWER SHALL BE OVERHEAD. DO NOT RUN CONDUIT ON ROOF. DISCONNECT IS PART OF UNIT. E.C. INSTALL CONVENIENCE RECEPTACLE/STEP DOWN TRANSFORMER KIT PROVIDED BY OWNER (SEE DETAIL 1/E-1) Q3 EXISTING UNIT TO REMAIN ■ ■■■■11111.■■■■■■1111 ■.■■.■■■■.■.■■■ ..■....■.......... ■.■1111■■.■M■■■.■■■ ■■■■.■■■..■.■■■■:• ■■1111■■■.■■1111■1111■ ■■..■■■■■■1111■■.■� ■■■■11■■■■11.■■■■■■ �� 1■Q��II■■1I�■11■■11��11■�I 41 41 1■II1111111111111■■II■11111■1111111■SII■11M1 -, W -, - - -, V - - - - - - - - - - - - FIL MEN 111111 11 1 11111111 ■■■■■■■■■■■■■■■■ ■■■■■■■■■1111■■1111■ 1 O MMM- MEMO mit I I Al 41044-11rAilr/Alt1 J 111Millismommomm �����■ i 111 11 1.1 0 0 •• •• 111111110 E 111111 M.D.P.-1 M.D.P.-2 ■ 1 O INII1111111111111111111■111■■1 O O EXISTING PANEL H3 ON MEZZANINE ■�E °■ ■`moi ■■■ NNE n o T O ELECTRICAL POWER PLAN SCALE: 1/16" = 1'-0" ll IliIHll'IIUIHIId11111I l- 0 "3 REVIEWED FOR ,CODE COMPLIANCE APPROVED DEC 2 6 2013 City of Tukwila BUILDING DIVISION RECEIVE CITY OF TUKWIL:A DEC 1 6 2013 PERMIT CENTER O z ELECTRICAL CHECKED: ANT/JGM z REVISION DATE: DECEMBER ISSUE DATE: SEPTEMBER ARCHITECT REFERENCE NO: J Z Z W 1-1-. _ d O z 0 0 0 mo a O wa U OI NO I- I - 0 — Orx 1- a aZ zo PROJECT NO:12-171