Loading...
HomeMy WebLinkAboutPermit M13-0233 - 1004 ANDOVER BUILDING - ALTERATIONANDOVER BUILDING 1004 ANDOVER PARK E M13-0233 • City of Tukwila Department of Community Development ? 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 1908 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.eov MECHANICAL PERMIT Parcel No: 2623049101 Permit Number: M13-0233 Address: 1004 ANDOVER PARK E Issue Date: 12/30/2013 Permit Expires On: 6/28/2014 Project Name: ANDOVER BUILDING Owner: Name: 1006 ANDOVER ASSOCIATES Address: 5851 S 194TH ST C/O CABLE MANAGEMENT, KENT, WA, 98032 Contact Person: Name: DAVE ANDRINGA Phone: (206) 779-6636 Address: 340 UPLAND DR , TUKWILA, WA, 98188 Contractor: Name: SEA AIRE INCORPORATED Phone: (206) 575-8051 Address: 340 UPLAND DRIVE , TUKWILA, WA, 98188 License No: SEAAII*2061Q Expiration Date: 4/26/2014 Lender: Name: Address: DESCRIPTION OF WORK: FOR FREEZE PROTECTION: SUITE 1006: INSTALL (2) REZNOR 100K BTU GAS UNIT HEATERS SUITE 1004: INSTALL (1) REZNOR 100K BTU UNIT HEATER Valuation of Work: $15,500.00 Type of Work: NEW Fuel type: GAS • Fees Collected: $533.44 Electrical Service Provided by: PUGET SOUND ENERGY Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 International Fuel Gas Code: 2012 WA Cities Electrical Code: 2012 WA State Energy Code: 2012 2012 2012 2012 Permit Center Authorized Signature: c Date: 1)-730-.(3 • • I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this permit. Signature: Print Name: Dame gndf,.� Date: I - )3 This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 2: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 3: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 4: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 5: ***MECHANICAL PERMIT CONDITIONS*** 6: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 7: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 8: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 9: Sprinkler coverage around unit heaters needs to comply with section 8.3.2.5 and figure 8.3.2.5 of NFPA 13 (2007 edition). 10: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 11: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0701 ROUGH -IN MECHANICAL CITY OF TUKW110 Community DevelopINnt Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.ci.tukwila.wa.us MechanicalIinit No.m.1;--- 02-3 Project No. (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION /OOP re' o k. ea- ii -d King Co Assessor's Tax No.: 63.30 ' /%D / - O 8 Site Address: /0 O a /0 O (, A n JOU-Q.1' n ("ark 6. I n/11D Suite Number: Floor: Tenant Name: New Tenant: ❑ Yes {.. No Property Owners Name: G 5 A Pro per I -i ei ZJ L Mailing Address: 585i £ /9`I S1` e..ti- City (/•/� State 9 b' a 3 2— Zip Zip CONTACT PERSON - who do we contact when your permit is ready to be issued Name: DA JLC AnSbik rte-- Day Telephone: C co) 77 9 -663 b Ti- 1411- t 8(S 8 Mailing Address: \340 U P( -A a`1 bit_ E-Mail Address: baU'e Ft SPQ -Q t «- . �•� City State Zip Fax Number6.3 73-- O6 5 -3 MECHANICAL CONTRACTOR INFORMATION Company Name: S e A _4t a-14 Mailing Address: 24.(c) L) AArt a lZ_ Contact Person: IA ,e- A I- D R Kl c E -Mail Address: baustete Sea --a tee_ Contractor Registration Number: SEA Alt Zp 6 T & 7,) kW, L-A- City LJh ?8/88 State Zip Day Telephone: (20 (aJ 7 7 9- 6 6 3 Fax Number: CLD) 75--06 5 3 Expiration Date: 7 —aZ 6 - (c{ ARCHITECT OF RECORD - All plans must be stamped by architect of record Company Name: Mailing Address: Contact Person: E -Mail Address: City Day Telephone: Fax Number: State Zip ENGINEER OF RECORD - All plans must be stamped by engineer of record Company Name: Mailing Address: Contact Person: E -Mail Address: H:\Applications\Forms-Applications On Line\2010 Applications\7-2010 - Mechanical Permit Application.doc Revised: 7-2010 \ bh City Day Telephone: Fax Number: State Zip Page 1 of 2 • Valuation of project (contractor's bid price): $ (fYt 1- oto o ' 7 t ( '1• s9,0 15 IS1,1) Scope of work (please provide detailed information): /rn,IT.4(( (L, Re zNc r ro o 00o gicu Gat Url1 t `,e,q-4ers rn Svc... / 0 66(un t4s Welty 4/v /65 CACI) and 1 Rez--uor /00,00Q 6Tv 00,4- G►eo er- in Sut'1•-e.. /ooti r -or -FreeZe_ Pr©f-en• nen gas -Freq.?. ivl e(-e.r C O u T. 60)11'. Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement 0 Fuel Type: Electric ❑ Gas Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Bioler/Compressor. Qty furnace <100k btu air handling unit >10,000 cfm fire damper 0-3 hp/100,000 btu furnace >100k btu ? J evaporator cooler diffuser 3-15 hp/500,000 btu floor furnace ventilation fan connected to single duct thermostat 15-30 hp/1,000,000 btu suspended/wall/floor mounted heater ventilation system wood/gas stove 30-50 hp/1,750,000 btu appliance vent hood and duct emergency generator 50+ hp/ 1,750,000 btu repair or addition to heat/refrig/cooling system Incinerator — domestic other menhanical equipment air handling unit <10,000 cfin incinerator — comm/ind PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 international building code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: '.(!Q. £24i4441 Print Name: DA J6 Day Telephone: (Z o rp� 77f -6b36 Date: /a — /4 /3 Mailing Address: 3 40 uPLA-KSI )J I Date Application Accepted: i-- 11_ � u ( 2 -TTvkwWA- id'/8A City State Zip Date Application Expires: {tn ( I ti 11 H:\Applications\Forms-Applications On Line\2010 Applications\7-2010 - Mechanical Permit Application.doc Revised: 7-2010 bh Staff Initials: 1 Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT I QUANTITY I PAID $411.56 M13-0233 Address: 1004 ANDOVER PARK E Apn:, 2623049101 $411.56 MECHANICAL $411.56 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PERMIT FEE R000.322.100.00.00 $277.25 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R518 R000.322.102.00.00 $101.81 $411.56 Date Paid: Monday, December 30, 2013 Paid By: DAVID ANDRIGA SEA-AIRE INC Pay Method: CREDIT CARD 00444G Printed: Monday, December 30, 2013 11:53 AM 1 of 1 CriW SYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS I PermitTRAK ACCOUNT I QUANTITY I PAID $121.88 M13-0233 Address: 1004 ANDOVER PARK E Apn: 2623049101 $121.88 MECHANICAL $121.88 PERMIT FEE R000.322.100.00.00 $65.00 PERMIT ISSUANCE BASE FEE R000.322.100.00.00 $32.50 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R412 R000.322.102.00.00 $24.38 $121.88 Date Paid: Monday, December 16, 2013 Paid By: DAVID J ANDRINGA, SEA-AIRE INC Pay Method: CREDIT CARD 01391G Printed: Monday, December 16, 2013 3:06 PM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 (\l 3-02.33 Project: A IQ ooJe z_ Rin i t c� Type of Inspection: 1-7--(1) A (_- Address: t(3QLI ►°t PE_ Date Called: Special Instructions: Date Wanted: ,-q.---1 3— (`{ a.m. tom' Requester: 1� `' eA tc1Ir` Phone No: -1pproved per applicable codes. Corrections required prior to approval. COMMENTS: p n R INS Date CTION FEE REQUIR D. Prior to next nspection. fee must be pa ' - 6300 Southcenter Blvd., Suite 100. Call o schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION. 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 i 3-33 Proj ct: jj f� �j Type of Inspection: Address: ! ooLt. ANi Ao•K.e. Q ICE. Date Called: Special Instructions: Date Wanted: _ Requester: DA•/Le' Phone No: alto 71g- b60.Z6, Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: t t_ 1 REI ' ECTION FEE REQ RED. Prior to next inspection, fee must be paid . 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD f Retain a copywith permit! M' 3" 02 3 p PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 4313670 cJV Permit Inspection Request Line (206) 431-2451 Project Project?, 1,i, 1A; Type of� spection 1j�19 --I n./ Address: I 10014 A°E.: Date Called: Special Instructions: Date Wanted: q— l l.% a.m. p.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: p - tor: CA.... --)C,( A. Dater R • NSPECTION FEE REQUIIRED. Prior tc� next inspection, fee must be p id/at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit A/3.-bZ33. PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: %w7L/eP— � Type of Inspection: �/ All; "lee G.0 'el: Address: Suite #: /06 4--/‘ Contact Person: Special Instructions: Phone No.: Approved\per applicable codes. Corrections required prior to approval. COMMENTS: A6"f(,7 /7 r G% S fy07/ //r, lr' Needs Shift Inspection: ,,,..... Sprinklers: Fire Alarm: Hood & Duct: �.. Monitor: Pre -Fire: Permits: Occupancy Type: Inspector:,��� Date: ,z1////5/ Hrs.: /. $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a rei 1spection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 HERMIT COORD COPY all c PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-0233 DATE: 12/16/13 PROJECT NAME: ANDOVER BUILDING SITE ADDRESS: 1004 ANDOVER PK E X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: `N. L_L:44±4( But rding Division ire Prevention Public Works Structural Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 12/17/13 Complete Incomplete Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 01/14/14 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: SEA AIRE INC LaborState Department of Labor & Industries • Page 1 of 3 SEA AIRE INC Owner or tradesperson MCCURRY, JOHN M Principals MCCURRY, JOHN M JUDY MCCURRY JENNIFER MCCURRY DEBRA MCCURRY FRANCIS MCINTYRE CHRISTINE MCINTYRE Doing business as SEA AIRE INC WA UBI No. 600 360 471 340 UPLAND DR TUKWILA, WA98188 206-575-8051 KING, County Business type Corporation Governing persons JOHNMMC CURRY License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties GENERAL License no. SEAAII*206JQ Effective — expiration 04/18/1980 — 04/26/2014 Bond AMERICAN STATES INS CO Bond account no. 6162430 $12,000.00 Received by L&I Effective date 04/18/2002 04/18/2002 httos://secure.lni.wa.gov/verify/Detail.aspx?UBI=600360471 &amp;LIC=SEAAII*206JQ&amp;SA... 12/30/2013 7f • • • • (i)'' . • ,. • JL Ij000 sgffi~- /.$ Sty 's per sqr} $8}.000 1+t wilco Pains Immo am ti*ESING crni • Noanif ifFIX ARV:1 E SALES zZSoo s9Fi. x 8 gross pee . 4§ Ff 1Q10,1700 �1/low�lo►e. Iso . 41t4 At` Yzu o N • 1.417 P0LE Doe ' 'ANDOVER PARK EAST SITE PLAN SCALE r=20' FILE LQpy Permit No. Phan review approval is subject to errors and missions. of conn documerl not authorize ._)':.-AtjonReceipt roved Field Copy and condikas isadocow ed: By IlAk Dals !a- 30 —/3 aty orr ,k was -ButIANC DIVISION • ' t CALAVO 61410144L 11FIE 141ER N. i 4 iTto 7' 4 L i 1 1% atm' oFFic i. q Rona ANALYSE moo PARI REQIREO . INSTALLS 51006: OF:10E O ?'3 t0005F • LT STALLS 4659g6F W O 1.0/10006r s. 47 STALLS NUL =UM • 60 SIAU.S < 6t PSON: D • 1D06 1 lo ass Mktg SEPARATE PERMIT REQUIRED FOR: 0 Me -chanted GPElectrical &Plumbing C aas Piping City of Tukwila BUILD1N a DIVISION hall be made to the scope thout prior approval of Building Division. wiil require a new plan submittal additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED DEC 2 6 2013 w V VM - City of Tuttvvila BUILDING DIVISION RECEIVED CITY OF TUKWILA DEC 16 2013 PERMIT CENTER Pr GOES ,)o. 26Z3o4-4101'08 SEA AIRE 0 Upkind Drive MODEL UDAP TECHNICAL DATA- Sizes 30 -125 Size RIGHT SIDE 30 45 60 75 100 125 input Heating Capacity BTUH 30,000 45,000 60,000 75,000 105,000 120,000 kw/h 8.8 132 17.6 22.0 30.8 35.2 Thermal Efficiency(%) 82 83 83 83 83 83 Output Heating Capacity" BTUH 24,600 37,350 49,800 62,250 87,150 99,600 kw/h ' 72 11.0 14.6 18.3 25.6 292 Gas Connection (inches) a• ral 1/2 1/2 1/2 1/2 1/2 1/2 ProNatupane 1/2 1/2 1/2 1/2 1/2 1/2 Vent Connection Size c (inches diameter) 4 4 4 4 4 4 Control Amps (24 wit) 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Amps (115 wit) 1.9 2.4 2.4 3.3 3.9 5.1' Maximum Over Current Protection (115V) D 15 15 15 15 15 15 Normal Power Consumption (watts) 109 155 155 217 276 354 Discharge Air Temperature Rise (°F) 50 55 60 60 60 60 Air Volume CFM 456 629 769 961 1345 1537 • Me/minute 12.9 17.8 21.8 27.5 36.7 45.9 Discharge JrAOpening Area 42 0.96 0.96 125 1.25 2.01 2.01 Rte 0.09 0.09 0.12 0.12 0.19 0.19 Output Velocity FPM 475 656 616 770 668 763 M/minute 145 200 188 - 238 196 245 Fan Motor HP E Open 0.02 0.03 0.03 0.06 1/30 1/20 Enclosed NA NA NA NA 1/4 1/4 Fan Motor RPM 1550 1550 1550 1550 1050 1050 Fan Diameter (inches) 10 10 12 12 16 - 16 Approximate Net Weight lbs 54 59 67 72 96 101 kg 24 27 30 33 44 46 Approximate Ship Weight lbs 61 66 74 79 118 • 123 kg 27 30 33 36 54 56 4.0 Clearances and Dimensions (cont'd) 4.2 Dimensions FiGURE 4 - Model UDAP, Power Vented Fan Model P and .Q-� Hanger p Dimensions for 4 -pt Suspension (4 -pt is required if installing optional Q nozzle.) 1 M M and N - Hanger Dimensions for both 2 -pt and 4 -pt Suspension R - Hanger Dimension for 2 -pt Suspension 1 TOP ViEW 3/8"-16 Female Thread - all suspension points t 1 • D B 11 L FRONT VIEW O N Thermostat Connection 15030-125 -400 HoVrizontalj 1t G 14 Combustion Air Inlet MO tTY MAP N0 SCAI E Line Voltage inlet (connects at circuit board) 4- H--► External Vent Collar (For Gas size, see Technical Connection Data in the APPENDIX on page 38.) F E Model UDAP Dimensions (inches t 1/16) RIGHT SIDE ABCD VIEW (Access Panel) O J ' K Model UDAP Dimensions (inches t 1/16) Size ABCD EF GH J ' K MNPCIR 30.45 12-1/8 26-5/8 10 13-13/16 26 21-9/16 5-3/16 6-1/2 2-11/16 3-7/8 17-3/8 11/16 4-5/16 13 9-9/16 60 15-1/8 26-5/8 13 13-13/16 27 21-9/16 7-7/8 6-1/2 5-1/2 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 75 15-1/8 26-5/8 13 13-13/16 27-5/8 21-9/16 7-7/8 6-1/2 5-1/2 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 100 23-1/8 26-5/8 17-3/8 21 13-13/16 28-5/8 21-9/16 14-1/2 6-1/2 8-3/4 3-7/8 11/18 4-5/16 13 10-1/2 125 23-1/8 26-5/8 21 13.13/16 29-3/8 21-9/18 14-1/2 6-1/2 8-3/4 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 150, 175, 200 20-1/8 38-3/16 16 23\ 42 35-3/8 8-1/2 8-1/4 5-7/16 6-1/2 25-11/16 1-3/8 8-3/16 22-3/16 16-3/8 225, 250 26-1/8 38-3/16 22 23 `'-•42 35-3/8 13-1/16 8-13/16 9 6-1/2 25-11/16 1-3/8 8-3/16 22-3/18 15-5/8 300, 350, 400 34-1/8 41 30 23 42 35-3/8 17-1/16 9 11-13/16 7-5/16 27-11/16 1-3/8 8-3/16 22-3/16 16-3/16 NJ' Al (.gyp)41- .17to.y i e Th eel*, o S1-14 *5 LIS ° t'�t.4 , v►ti_c� d+.r.. ktou ev4er,0, Ov n Q cd-e✓S »4!4-j 46 :`` Iovvt ; 9% �urlsnS On %S�r'3 : 14% "6 All -Area J Veil 4' A eAkrs Aro ==c711 otter 6"Drtp141 -.SHUT- VALVE • LIRI -.. tZEGEtZ , azismAgce:..`mom coMeti4ariz .v2 TOP OR.. . Ft.. UE • c,orro M ..: • . Cv_"_ 1 f51 1 ." 32"' 1 1 w CC ect CO REVIEWED FOR CODE COMPLIANCE •APPROVED DEC 2 6 2013 City of Tukwila BUILDING DIVISION • - • • RECEIVED CITY OF TUKWILA .DEC .16 2013 PERMIT:CENTER LU v 0 0) 0) •c CCw 0 CI CO F- CO hitt CC AC .a. CC LLI 0 z m a 0 Y 0 0 CO CO ac; O) olt F i