Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-0237 - MCCORMICK AND SCHMICK - ALTERATION
McCORMICK & SCHMICK 9404 E MARGINAL WAY S M13-0237 Parcel No: Address: Project Name: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-438-9350 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT 5729800010 9404 EAST MARGINAL WAY S MCCORMICK AND SCHMICK Permit Number: M13-0237 Issue Date: 3/31/2014 Permit Expires On: 9/27/2014 Owner: Name: Address: Contact Person: Name: Address: Contractor: Name: Address: License No: Lender: Name: Address: MUSEUM OF FLIGHT FOUNDATION 9404 E MARGINAL WAY S, SEATTLE, WA, 98108 JOE RONHAAR 1726 STANWOOD-BRYANT RD , ARLINGTON, WA, 98223 RESTAURANT REFRIGERATION & RPR 1726 STANWOOD-BRYANT RD , ARLINGTON, WA, 98223 RESTARR8830E Phone: (425) 387-7990 Phone: (425) 387-7990 Expiration Date: 9/5/2014 DESCRIPTION OF WORK: REMOVE EXISTING REFRIGERATION. INSTALL NEW REFRIGERATION, CONDENSING UNITS, LINE SET, EVAPORATION, BOXES. Valuation of Work: $2,500.00 Type of Work: Fuel type: Fees Collected: $224.88 Electrical Service Provided by: SEATTLE CITY LIGHT Water District: TUKWILA Sewer Distric: TUKWILA SEWER SERVICE Current Codes adopted by the City of Tukwila: Internations Building Code Edition: International Residential Code Edition: International Mechanical Code Edition: Uniform Plumbing Code Edition: 2012 2012 2012 2012 International Fuel Gas Code: WA Cities Electrical Code: WA State Energy Code: 2012 2012 2012 Permit Center Authorized Signature: Date: l/.3/3/A� • • I hearby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this development permit and agree to the conditions attached to this • • rmit. Signature: Print Name: Date: 3/o//y This permit shall become null and void if the work is not commenced within 180 days for the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. PERMIT CONDITIONS: 1: ***FIRE DEPARTMENT PERMIT CONDITIONS*** 2: All new sprinkler systems and all modifications to existing sprinkler systems shall have fire department review and approval of drawings prior to installation or modification. New sprinkler systems and all modifications to sprinkler systems involving more than 50 heads shall have the written approval of Factory Mutual or any fire protection engineer licensed by the State of Washington and approved by the Fire Marshal prior to submittal to the Tukwila Fire Prevention Bureau. No sprinkler work shall commence without approved drawings. (City Ordinance No. 2327). 3: Sprinklers shall be installed under fixed obstructions over 4 feet (1.2 m) wide such as ducts, decks, open grate flooring, cutting tables, shelves and overhead doors. (NFPA 13-8.6.5.3.3) 4: Maintain sprinkler coverage per N.F.P.A. 13. Addition/relocation of walls, closets or partitions may require relocating and/or adding sprinkler heads. (IFC 901.4) (EXTEND FIRE SPRINKLER COVERAGE TO THE WALK-IN COOLER/FREEZER.) 5: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 6: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 7: ***BUILDING PERMIT CONDITIONS*** 8: Work shall be installed in accordance with the approved construction documents, and any changes made during construction that are not in accordance with the approved construction documents shall be resubmitted for approval. 9: All permits, inspection record card and approved construction documents shall be kept at the site of work and shall be open to inspection by the Building Inspector until final inspection approval is granted. 10: All construction shall be done in conformance with the Washington State Building Code and the Washington State Energy Code. 11: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 12: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center. 14: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. • • 15: ***MECHANICAL PERMIT CONDITIONS*** 16: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 17: Manufacturers installation instructions shall be available on the job site at the time of inspection. PERMIT INSPECTIONS REQUIRED Permit Inspection Line: (206) 438-9350 1400 FIRE FINAL 1800 MECHANICAL FINAL 0609 PIPE/DUCT INSULATION 0705 REFRIGERATION EQUIP 0701 ROUGH -IN MECHANICAL CITY OF TUK Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 hup://www.TukwilaWA.gov Mechanical Permit No. Project No. «i /3- 0a37 Date Application Accepted: /9-(a'-(//3 Date Application Expires: D(Q(?Y7/ V (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Q King Co Assessor's Tax No.: S1 Pleb t iO Site Address: (ACyd\— V`(tiekr(�� 1,nrL` l.0 ikL,1 Suite Number: Floor: Tenant Name: W \ C.Q,c, twyn \rte G.. . - r r K New Tenant: ❑ Yes ❑.. No PROPERTY OWNER Name: --3--, \-ori\,,,, f Address: l-� `j . xz� _P �\ 1 _ t Name: M0' 7rC\ 04 \--4 \%\i.,\--' Address: Fax: 3 �o CS a )2- i (-c. Contr Reg No.: .n pi ti " I F tpDate:. City: S2SN `t Wa gg ,, cl .? �2S CONTACT PERSON — person receiving all project communication Name: --3--, \-ori\,,,, f Address: l-� `j . xz� _P �\ 1 _ t City: r 1 `�� State: L Zip -,96)a PhoI`-tac - •K��-�gga Fax:3Coc)-6S a-3al (P Email: MECHANICAL CONTRACTOR INFORMATION Company Name: l� �� , y..\e.s 4. 1� 1� ` � �QS1�t_� uz� Address: l.i gior v, ''' `?—,t1 City: S et: Zip: Phone: y-sa8-7-`l Gqo Fax: 3 �o CS a )2- i (-c. Contr Reg No.: .n pi ti " I F tpDate:. I I Li Tukwila Business License No.: Valuation of project (contractor's bid price): $ 7 Describe the scope of work in detail: 6(uLx,novQ,n�S )-,�r. 1�r1 Y1R1."J ft:4(N \o 4 �s-� G-rYNAtrt-Ni ; U 1'ti k'1"; i v,L ‘jo t- Q. V k) k.\—wl 1 ((./:i•Jk.5 Use: Residential: New VReplacement Commercial: New Replacement ❑ Fuel Type: Electric ❑ Gas ❑ Other: ` c•\.QpCi HAApplications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for whichno permit'is-issued within 180 days following the date of application shall expire by limitation.. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING WNER OR AUTHORIZED AGENT: Signature: (p ^� 0 Print Name: Mailing Address: ' —PDC H:Wpphcations\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 l.docx Revised: August 2011 bh Date: I - a.3 --1-3 Day Telephone: LOS -- 14c1— i l��L3 0(8aa3 Cit State Zip Page 2 of 2 Cash Register Receipt City of Tukwila DESCRIPTIONS ( ACCOUNT QUANTITY PAID $200.50 PermitTRAK M13-0237 Address: 9404 EAST MARGINAL WAY S Apn: 5729800010 $200.50 MECHANICAL $200.50 PLAN CHECK FEE R000.322.102.00.00 $20.60 PERMIT FEE R000.322.100.00.00 $147.40 PERMIT ISSUANCE BASE FEE TOTAL FEES PAID BY RECEIPT: R1643 R000.322.100.00.00 $32.50 $200.50 Date Paid: Monday, March 31, 2014 Paid By: REHN BROOKE REFR Pay Method: CREDIT CARD 01282C Printed: Monday, March 31, 2014 12:47 PM 1 of 1 CRSYSTEMS Cash Register Receipt City of Tukwila DESCRIPTIONS PermitTRAK ACCOUNT QUANTITY PAID $24.38 M13-0237 Address: 9404 EAST MARGINAL WAY S Apn: 5729800010 $24.38 MECHANICAL $24.38 PLAN CHECK FEE TOTAL FEES PAID BY RECEIPT: R489 R000.322.102.00.00 $24.38 $24.38 Date Paid: Tuesday, December 24, 2013 Paid By: JOSEPH RONHAAR Pay Method: CREDIT CARD H22917 Printed: Tuesday, December 24, 2013 9:59 AM 1 of 1 CRWSYSTEMS INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro' I \C�rcR�.� Y\``� Type f_Inspection: -.,>ur4 k Address: Date Called: Special Instructions: Date Wanted: a. Requester: Phone No: CriA.Approved per applicable codes. Corrections required prior to approval. COMMENTS: r-� } ,N -L1 Date 1y REIV PECTION FEE REQ I IRED. Prior to next inspection. fee must be at 6300 Southcenter lvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. CITY. OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 M13---0237 PERMIT NO: Project: / 4 (AO/VC Me $ S. LA4161( Type of Inspection: e �I---- /UIe�:. f . Ai Address: 4/ 410 E: MA/6 :t141 - -P. Date Called: t ;,.>.)„-r--- L? ii.5. Special Instructions. t .-- At.t/gef?, • t �.. t, ..). Date Wanted: p.m. Requester: Phone- C ..•— 3 ----751 N JApproved per applicable codes: Corrections required prior to approval. COMMENTS: me. 6,41... f J460:::,(1 ,(1 -Pre- S r'rK1-US rP Date / ) 4 n REINSPECTION FEE REQUIED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd:, Suite 100. Call to schedule reinspection. Insp tor: INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit Pi(/' avo z PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: �i(/k (& 7 !% ' 7 j Type of Inspection: ;04/ ;.4 ri .rt ,-- % / Address: C/ Suite #: t5/ Z-% 2 / A/5 Contact Person: Special Instructions: k4.60.r. C3) Phone No.: Approved per applicable codes. Corrections. required prior to approval. COMMENTS: Sprinklers: ac Fire Alarm: Hood & Duct: Monitor: Pre -Fire: /'5/i/tv,,,,, /pr..., -4 r k4.60.r. C3) //v wwJ ljvit7/C. •✓ luaus' , ,ceez.e./" `.,_._ /4/( j filvdc>°.s _ Nd /vQui .__� �/ia /,/LS �(7 At_ Alga) �Gf N/15- 76/ e /i 1,/ /0 f Needs Shift Inspection: Sprinklers: ac Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: 5 Hrs.: /. $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: r /44 .4 /1 T r 11 r_..__ r n • r ^1 FILE COPY pr 74 c o icO DEC 2.4 2013 POW T CENTER REVIEWEDFOR CODE COMPLIANCE APPROVED MAR 2 0 2014 City of Tukwila DING DIVISION :: _Immo= ssss u• •s= Msg::■■: :..s I ■ ■..t,.■.: ■:s: ■■ TO S : ■■:■■v4 upr::. ..i �� :IH!!IjIlI!IIIEuuiIiiiiiiHiiiIiIu!IIIii NI 17 IlmgremMil gm • oil= ■: s ::i■..■s • 1M MN • : I.IIIIIIIIM ■ s IP::!iNiH::HI!ifl!IAhIbIiIiIiH1lIIiI.Umeili ■ `'-��c�-"�C.sGiG.:��'�-c'.� MI ep, lir 4111 - MOM mum ■■:4 um H.s s.� s 1 er ginmm m m t r Heatcraft Refrigeration Products LLC -. 2175 West Park Place Boulevard Stone Mountain, GA 30087 • (770) 465-5600 SUBMITTAL DRAWINGS Models MOH/MOS (11/2 - 2 HP Air Cooled Condensing Unit (00/� Location: r r omer: Order No. tity: Item No. Model No. Qty: AIR FLOW Outdoor (Left View) 281/4 r —pt to Suction Liquid 21 1/8 CL 1 4 /16 ►1 �� �9 /18 k,(% • ,/18 SiOtS 9 2 /16 US 1 J1/4 L r Outdoor (Front View) 37 3/4 t.� Date: by: for approval [Dor record Indoor (Front View) 1 18 ili Power Conns: 7 1 1) /8 & (1) 1 /8 i() 2 3/4 4 4 1/1 63 -+- wawa envocrupwu I DEC; 2 4 2013 7 /18 X 11 /16 SlOtS PHYSICAL DATA 1 4 L 391/8 Vve414 MOH R -404N507 Hermetic Model Size MOH015X62 Compressor Model No. CS 10K6E Connections HP Liquid inches 3/8 Suction inches 5/8 Receiver Cap.(90%) 9 Net Weight-- ft:DLyle br 19&PPi Sound Data. MVO 9kdbal PERFORMANCE DATA MAR 2 0 2014 R- 404A/507 Ext. Temp Model Capacity (BTUH) @ 95°F Compressor Suction Temperature °F City of Tukwila 30°F 25°F 20°F 0°F -10°F -20° El ILDIWEIVISIO MOH015X62 15040 13830 12580 7260 4620 3410 2200 ELECTRICAL DATA Hermetic Model Number Power Supply Compressor Fan Motor MCA MOPD Evap. Fan Amps. Defrost Heater Amps. Volts Ph Hz RLA LRA Qty. Hp Fla Air Elec. Air Elec. MOH015X62 208-230 1 50/60 9.8 56.0 _ 2 1/15 1 15 24 20 25 6.0 19 Estimated sound pressure values are 10 feet from the unit. For estimating sound pressure from the unit at different distances, deduct the following from the unit values: 20 Leet, deduct 6 dba for 40 feet, deduct 12 dba for 80 feet, deduct 18 dba This data is typical of 'free field conditions for horizontal air coded condensing unite at the outlet d the discharge alr. The actual sound measurements may vary deperdng on the condensing unit Installation. Factors such as reflecting walls, background raise and mounting conditions may have a significant influence on this data 0 Healcraft Refrigeration Products LLC, 2002 Panel HTS080802c LARKIN SUBMITTAL DRAWINGS 2175 West Park Place Blvd Model LCA6 (6 FPI Air Defrost) 60 Hz. Stone Mountain, GA 30087 (770) 465-5600 Low Silhouette/Profile Coolers &DC 1 314' - 44 mm A ® 4 0 0.0 • 43/16" !06 mm 1 15116' 49 mm Electrical .. Cconeealono 13 7116" I341 mm �W `�■i'_i 'ter + 8 118' ' 'jI 118" 156 mm I B 156 mm T- Refrigerant Connection End 22 mm e 718" Electrical /Knockouts // 2 118 9z E 54 nun 1314' ---moi + 44 m — F"— m 11/2" 38 mm 14 1515/ 379 mm 19 mm 3/4" MPT 11414'51 Drain Connection PHYSICAL DATA PENNED err/ ocTuvr. 4 IDEC 2 4 :2013 12 3/8" I 314 mm 16- 1. 407 stun 12" Fes- 13/4' 308 tit44 mm m 14 7/8" 377 mm LCA6 Model Size Connections (Inches) 7/8" ID 1/4" OD Dimensions Inches/cm 491/4 1251 --- Approx. NET Weight Coil Inlet Suction External Equalizer A 1 B C 1 D lbs. 1 Kg. LCA6135 I 1/2" OD 7/8" ID 1/4" OD 611/2 1562 491/4 1251 --- --- 67 31 i1 LCA6135 60 Hz. Capacity Fan Data 60 Hz. Total Motor (1/15 HP) Amps / Watts (60 Hz.) LCA6 @ 10°F TD / 6°C TD 3568 Diameter Air Flow Shaded Pole PSC, PSC -TE 115/1 208-230/1 115/1 208-230/1 460/1 Model Size '@ +25°F SST / -4°C SST Qty. Inicm FM BTUH 1 Watts i1 LCA6135 13,500 3,950 3 -- 12 - .- - 30 - -, 2100 3568 5.4 348 3.0 366 o ems"; t..ucs_Ma II x,10 ' 0�2Qt6�7;ekt2eAts.,(35/ 6th itu)imnr-M !/fs it a MAR 2 0 2014 City of Tukwila BUILDING DIVISION • Heatcraft Refrigeration Products LLC 2175 West Park Place Boulevard Stone Mountain, GA 30087 • (770) 465-5600 'Plr�Z. SUBMITTAL DRAWINGS Models MOZ (3 - 6 HP) Scroll Air Cooled Condensing Unit Project: Arch/Engr: Customer: Identity: Location: Outdoor (Left Vi 28-1/4 Item No. US crol Order No. Model No. Qty: Outdoor (Front Vk 19-3/4 7/16 X 11/16 slots 37-3/4 Date: by: for approval for record Power Conns: (2)7/8,(1)1 3/8 & (1) 1 3/4 15 4 /16 3 13/16 3 1/4 3 Indoor (Front View) PHYSICAL D TA Cgnnections Compressor 37-3/4 Receiver Cap.(90%) r °slet Weight 5 1/4 OF RI CITYTURIN" ° [DEC 242013 that ° sseoat Sound Data ,W....,, moao� Size ------- No. HP __ inches inches Ib lbs. ana �P�' Amps Defrost jester Amps 1 Volts Ph Hz R -404N507 MOZ035L63 ZF11K4E 3.5 1/2 1-1/8 20 217 73 PERFORMANCE DATA Low Temp Model R -404A/507 MOZ035L63 Capacity (BTUH) @ 95°F Suction Temperature °F 0°F -10°F -15°F -20°F -25°F 19,040 15,860 14,340 12,.900 11,540 L DATA l��/aicrriD.=f16: I PD'°F ren i 10,3x00&, APPROVED nnRiP?R°lANw• E Scroll Model Number Power Supply Compressor Fan Motor MCA iFan P� MOI 2 �P�' Amps Defrost jester Amps 1 Volts Ph Hz RLA LRA Qtv. Hp Fla Air gg Eled Air Elec. MOZ035L63 208-230 3 50/60 13.5 99.0 1 1/3 3.5 20 29 1 25C k...n nnh V of i ehh��nh c. r6Q(iflla nncn n--UnY 23 rn ri N O Heatcraft Refrigeration Products LLC, 2002 - — Panel'HTS080802q LARKIN 2175 West Park Place Blvd 'tone Mountain, GA 30087 • (770) 465-5600 zc/ SUBMITTAL DRAWINGS Model LCE 6/4 (6/4 FPI Electric Defrost) 60 Hz. s ! ". oso • 1 43/16" 106 mm 1 4 4" —� r_, 115116" Q4 mm 1 q 49 mm I Refrigerant Connection End 0 6 1/8" 22 mm • 718" Electrical to Knockouts 1 3/4" Tf +� 44mm I 11/2" 38 min Electrical Connection End 13 7/16" 1341 min 156 mm 14 15/16" 379 mm 19 mm 3/4" MPT {I4 NPSI Drain Connection PHYSICAL DATA 6 1/8" 156 mm REBEIWID CITY OF TUKWILA IDEC 2 4 2013 PaRter cam 12 3/8" I 314 mm 16" J407mm I2" L314 " 305 mm 44 mm 14 7/8" 377 mm LCE6 Model Size Connections (Inches) Fan Data 12" dia. (30 cm) CRY- 60 Hz. Air Flow CFM/ m3H Dimensions Inches/cm Defrost Heaters Approx. NET Weight Coil InLCE6 Suction External Equalizer A B C D lbs. Kg. LCE6 (6 1/2" OD 7/8" ID 1/4" OD 611/2 1562 49Y 1251 60 28 PERFORMANCE DATA Model Size LCE6 60 Hz. Capacity @ 10°F / 6°C TD @ -20°F /-29°C SST Fan Data 12" dia. (30 cm) CRY- 60 Hz. Air Flow CFM/ m3H Total (1/15 HP) Motor Amps/ Watts (60 Hz.) Defrost Heaters Shaded Pole 208-230/1 -- ---- PSC, PSC -TE Watts Total Amps (60 Hz.) BTUH Watts 208-230/1 460/1 2" „,..,„ ems. w .�" 1,230/1 ,..230/3' 460/1 „uJ e v, G II MAR 2 0 2014 City of Tukwila BUILDING DMSION • VR%ls l= L#ni r 6a1"V1V4d1.,. 12,000 3520 ' 2100 3568 3.0 366 1.5 273 1.2 351 274 ri prr1t1f7917 il 6.8 1 5.9 », k 4. -- i MAR 2 0 2014 City of Tukwila BUILDING DMSION • L..,�t., s ► �� O� L ; c `-\O' .r(J\ 7a vc;� Lim' Toto, . FILE COPY Perrot No. Uc_Al1 \r;t l Ui W W�� (�� '� C \^ 1 ',½:: 1 " a —\ \t �t*e \r k, To 4 \w REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 0 2014 • 3!�!L©ll�G Ci of Tukwila DIVISION tf�Y� Tuoiso 1 DEC 2 4 2013 PentWeleffilft IU�13-023' REHN BROOKE REFRIGERATION Qu tatl©o 01l Quote #: 170046 Quote Date: 09/21/2011 Revision: 11/05/2013(#6) Ill COP U PeAvnik No. Erown17001ta WALK -ORIS Refrigeration Condensing Unit for Holding cooler O Manufacturer. o Description: o Model: • Horsepower. o Extras: Y Electrical: o Conditions: o Warranty: 1 x Evaporator (Unit cooler) o Manufacturer: o Description: o Model: o Extras: o Electrical: Condensing Unit for Holding freezer o Manufacturer: O Description: o Model: o Horsepower: o Extras: o Electrical: o Conditions: o Warranty: 1 x Evaporator (Unit cooler) o Manufacturer: o Description: o Model: o Extras: o Electrical: Heatcraft Med Temp R404A Air Cooled Hermetic Remote Outdoor Condensing Unit with microchannel condenser MOH015X62CFMT 1.5hp Defrost timer, Drier, Sight glass and Shutoff valve installed 208-230/1/60, RLA 9.8, MOPD 20, MCA 15 BTUH: 13960 Room Temp: 35°F Ambient: 95°F Compressor -motor warranty extended to 5 -years, parts only, no labor Heatcraft Air defrost Low profile coil (unit cooler) 115/1/60 with EC fan motors coil LCA6135AEB with expansion valve solenoid and thermostat shipped loose ECM fan motors 115/1/60, Fan amps 2.9, Defrost amps N/A Heatcraft Low Temp R404A Air Cooled Scroll Remote Outdoor Condensing Unit with microchannel condenser and energy saving Smart Defrost MOZ035L63C 1 3hp Defrost timer, Drier, Sight glass and Shutoff valve installed 208-230/3/60, RLA 12.2, MOPD 30, MCA 29 BTUH: 12900 Room Temp: -10°F Ambient: 95°F Compressor -motor warranty extended to 5 -years, parts only, no labor Heatcraft Electric defrost Low profile coil (unit cooler) 208-230/1/60 with EC fan motors coil LCE6140BEB with expansion valve solenoid and thermostat mounted ECM fan motors 208-230/1/60, Fan amps 1.6, Defrost amps 11.7 Disclosure: • All quotations and order shall be subject to CrownTonka, division of Crown Fixtures, Inc. standard terms and conditions notwithstanding any additional or contrary terms and conditions of Buyer. Such additional or contrary terms shall not bind Crown Fixtures unless accepted in writing even though such terms do not materially atter the terms hereof. No oral statements, warranties, stipulations, representations or terms shall have binding effect or be any part of the contract whatsoever. All orders must be in writing and will be binding when our order acknowledgement is mailed, faxed or emailed. If customer does not have a copy of these terms and conditions, please contact the customer service department. o Price quotations are valid for 30 days from quote date shown on printout. • Terms: subject to credit approval. o Quoted price DOES NOT include any applicable sales tax. Ask your customer service representative for a list of states in which sales tax is collected. If item is resale, a copy of your resale exemption certificate must be on file with CrownTonka prior to shipping, otherwise sales tax may be charged. o All shipments to IA are subject to use tax per the Iowa code. Resalelcertificates do not apply. o Lead Times vary depending on the production schedule. Please consult you customer service representative for an actual lead-time. o Structural or seismic calculations and materials are not included unless shown on quote or requested. We hoe this quotation meets with your approval and if we can be of further assistance please do not hesitate to Fconvtq�yourEcustorler s `rvice representative. Thank you for the opportunity to submit this quotation. CQRese tJde'the (tt otation reference number with all enquires pertaining to this document. AWED Sincerely, MAR0 2014 Oso.,,y vU YYW roFu IDEC 242013 • kr1 BUILDING DIVISION 6 of 8 °eRM \I�IMOZ. 1 ,0 vo-rey.fluze_um Aefre 400" aelety)peS(Ad1.0) exrecoacc) co24 tam' CY,A.ew 1 -AVIS ecr.s j.ed_tcavC ; • - MCP'15e7) ‘4% • • • 14 ligi3771V0 .341:VMAGC (..41FW easC *MIX di: • f? (I? 41 BUS PARKING EXISTING MUSEUM STRUCTURE Area of work fi EXISTING HANGAR EXI S TIFIV-121 SPLAY VIA. WILCOX CONSTRUCTION INC OtNC8 1 8 0 3 North FILE C PY cie.yrnit No. RECEIVED CITY OF TUKWILA JAN 07 2014 PERMIT CENTER Wilcox Construction, Inc 234 5th Ave S. Edmond, WA 98408 425-771-4185 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 0 2014 City of Tukwila BUILDING DMSON MRRECTKM, AA n-o2_v Museum of Flight 9404 East Marginal Way Seattle, WA Walk in cooler replacement 12/15/13 Site plan G1.0 RU -6' cooler freezer LOUVER TTArdw MUSEUM STORAGE EXIST.* 5Wl LC OX Dtil CONSTRUCTION INC YtwNf EFINCS 1262 Wilcox Construction, Inc 234 5th Ave S. Edmond, WA 98408 425-771-4185 A—A BASEMENT PLAN sCM1 116' -w'—O 1'- 3' / RECEIVED CITY OF TUKWILA City of Tukwila BUELDING DI �BSQOi ��1�lorth Museum of Flight 9404 East Marginal Way JAN 0 7 2O14 Seattle, WA Walk in cooler replacemenPERMIT CENTER 12/15/13 Existing plan A1.0 Demo notes #1. Remove existing walk in cooler and freezer wall and floor panels #2. Remove 10'x 8' section wall behind freezer to storage rm #3. Remove ceiling grid to allow for walk in removal and replacement #4. Clean and seal concrete floor in cooler area PtuuBwC OUSE Fait PgorEcn SEE MECHANICAL. Lawe rnAro 4 . MUSEUM STORAGE O/wR� SINGS 1 11 0 0 Wilcox Construction, Inc 234 5th Ave S. Edmond, WA 98408 425-771-4185 Museum of Flight 9404 East Marginal Way Seattle, WA Walk in cooler replacement 12/15/13 Demo plan RECEIVED lei CITY OF TUKWIL JAN 0 7 2014 PERMIT CENTER A2.0 LPLWeetc crosE nRE. PaoTEcnG4 SEE WECNuCCAL. EXHAUST DUCT install new compressors below existing compressor MUSEUM STORAGE CONSTRUCTION INC WILCO!• RI NCB 1803 Wilcox Construction, Inc 234 5th Ave S. Edmond, WA 98408 425-771-4185 EXIST.t- -!' Pr -Y 67'-4 Ij2' BASEMENT PLAN SCALE 'ir •I-0' i Via© FOR: CO6 PLIANC PPROVED 1.1AR 2 0 2014. City ofTuC-al- BI J LDING CoMSCOk North ._* Museum of Flight RECEIVED 9404 East Marginal Way CITY OF TUKWILA Seattle, WA JAN 0 7 2014 Walk in cooler replacement 12/15/13 PERMIT CENTER Proposed Floor plan A3.0 1131N33111A1113d REHN BROOKE REFRIGERATION Quotation Quote #: 170046 Quote Date: 09/21/2011 Revision: 11/05/2013(#6) C __ rown 1,„i,. i ' i- t „, r WALK-INS Box description: Cooler/Freezer Combo -- Front elevation 288" 10 -36u -DI 1* -36"--01 Museum of Flight 9404 East Marginal Way Seattle, WA Walk in cooler replacement 12/15/13 Cooler info EQ1.0 -, 7., ; A , ; : : . . z : ; 1 ; 1.1% : . : : 10 -36u -DI 1* -36"--01 Museum of Flight 9404 East Marginal Way Seattle, WA Walk in cooler replacement 12/15/13 Cooler info EQ1.0 831N3311Wa3d REHN BROOKE REFRIGERATION Quotation Quote #: 170046 Quote Date: 09/21/2011 Revision: 11/05/2013(#6) Crown , f I AU( -I NS Box description: Cooler/Freezer Combo 0 pV CD x r 24' 0" 14'0" 10' 0" LIp 4? ! O 7p 0 LII ! tl m u L 1 1 a i t 1 35°F Holding cooler 4" walls, 4" cdiling, floorl�s 96" high; foam rail,+Iockwalls o N it/ext: GalvanizediiEmbossec - 1 s 1 0 1 ° -100q Holding froe; iO4" walls; 4" ceiling,; 4' 96" Ih, foam rail, Tock ova :0 Lock walls to flo Galvariized/Em bass Iggr int: Albminum/Sino: *Kt: Galvinized/Embossed ilia • 1 1 f f f 1 24" fatam0 Accepted By: co e O S 31611 = co x0 M a ® 1 m eil 5 IND 0 Tzt o 0 RI 0 7'61 3'6" w 119 Ga. Museum of Flight 9404 East Marginal Way Seattle, WA Walk in cooler replacement 12/15/13 Cooler info EQ2.0 Bolt Ceiling to Wall ith Fascia rom 10 P/CKIo 87 INSIA11[n .675' - 21' PLEK000 !ASCU 10 001 5675' BEYOND 101 or NAI END PUN 00 HAVE TWO .315' I S. U6 SCR[KS ammo 91 0140 FLUE. (000 SCR['R AI [AGN [NO ova NAIL KEPI 0111510E STUDS 10 1400 IMO 500(NS FEB KALI PARE MOP. GASKETS 10 M 511/110 10 TO' PUT AS 540009. SECTION THRU 3.5" CEILING AT 3.5" WALL 3" = 1'-0" 50141 PROPORTIONS AUK KEEN 01414I04IE0 Poi CU9nr. -Lock Ceiling to Wall wit rim Strip (standard ri.sigiour wilwp CM= IRM GAPS IN51Alu0 IN FILO MIN 5/1' [0 HU NERD SCADS RIP CE1LDIG PUIE EO 1.3315'. NOTCH CEILING MOS FOR RANKS. RP END CEILING MOS TO 1995'. YORK CUM ID YARN WILL MON. CEILING PANEL. YETAL TO MEND _75' 9000110 WAIL. NALL 10 CM1NG PANEL WALL PANEL. SECTION THROUGH WALL AT CEILING 3" = -I'-0" Cam -Lock Wall to Ceiling \11 with Cap (optional). 111 CCM PUI1 10 1.595'. maiCERO70 11005 !p IIN05. W ENO CEIUG SIUOS TO 1.1311'. NORSE RANK 10 111101 NIU IILON. —R-ut ID cam .13' R[1078 Nm. ®�:•, l I� A U Cr NAU PLAT 70 h a�. o 0 ) 6u i ?I NZI r, (�r I u r 3" = I,-0. __ 110A F. SECIION IIIROUGII WALL Al CEILING CZ :11 h CROWNTONKA� WA LK -I NS CONSTRUCTION DETAIL Anchor Walls to Concrete Floors SECTION THRU WALL AT FLOOR 3" = I'-0" Kut PANEL /IIGNwrwr SIB? NOSH I100R 00IGNYENI SAP *HUN 10 1IN4N 11000 K/11110 mon 101E Typ .I Recessed Floor wi Threshhold 0014 PANEL — MAL 101[50010. -- root RECBSIo 11061 FOIL o 3.5" RECESSED FLOOR DETAIL AO 3" = 1'-0" 5014E • I *NS NAK NEIN [SACG[RA tutu. I 6031 Typical Ceili : Support ALE NU1 DWI 10 PIAU[. 1 13 I I/6' SIEIL PUIE KIM HOLE of CINIE0 109 ROD. 900109 CHORD 01 OAR 104515. Museum of Flight 9404 East Marginal Way Seattle, WA Walk in cooler replacement 12/15/13 Cooler into EQ3.0 CUSTOM MANUFACTURERS OF WALK•IN COOLERS & FREEZERS 10700 HWY 55 • SUITE 160 • PLYMOUTH, MN 55441 m n C z Om :Li 0 C) ..4 -.1 ITT C Z0 7;m M gv 33 • PHONE: (763) 541-1410 • FAX: (763) 541-1563 • 1-800-523-7337 (PANEL #53) • • 1:131N33111A11:13d Ceiling Transition 5.25' CEILING TRANSITION TO 3:5. CEILING 3' = t'-0' Angled Wall Panel 9.0000 7.625 0 7-71 Om C< CROWNTONKAT~ WALK—INS 42,1' -0140NINANWPMESIMII CONSTRUCTION DETAIL CONT. Wall to Floor ® 3.25' C0SN10N Ott. ® 3.5' CCM S1000. © 3.5' CflUNG PANEL © 5.25' CflUNG PAWL. •® 4.3125' 011ER0R IInAL U.c etar (ro-oaatto). ;f. 1022 3 I/2' r•T�� IP�` — �� 3.5' WALL 0 A' FLOOR = 1.-0' t1U NIL IOIQ*D ■IIA Put( .115' ORD ST= On CPC 1325' NU WO Iun1G 61t t'U UM IIXI MI111101 float I COIMUl COSI OIL MI 603E SPECIAL CONSTRUCTION ur Sided Column Notch For Col closure r0 fl Museum of Flight 9404 East Marginal Way Seattle, WA Walk in cooler replacement 12/15/13 Cooler info EQ4.0 CUSTOM MANUFACTURERS C 10700 HWY 55 • SUITE 160 • PLYMOUTH, MN 55441 • PHONE: (763) 541-1410 • FAX: (763) 541-1563 • 1-800-523-/337 January 16, 2014 • City of Tukwila Department of Community Development JOE RONHAAR 1726 STANWOOD-BRYANT RD ARLINGTON, WA 98223 RE: Correction Letter # 2 MECHANICAL Permit Application Number M13-0237 MCCORMICK AND SCHMICK - 9404 EAST MARGINAL WAY S Dear JOE RONHAAR, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Dave Larson at 206-431-3678 if you have questions regarding these comments. • 1. Please provide floor anchorage details for the walk-in cooler and freezer. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. M13-0237 K7M quit, limn • Tulru,iln Wnchinotnn 05215252 a Phnno ,nt;-421. 7n Fnv 7nK-44 _7FfS January 06, 2014 City of Tukwila Department of Community Development JOE RONHAAR 1726 STANWOOD-BRYANT RD ARLINGTON, WA 98223 RE: Correction Letter # 1 MECHANICAL Permit Application Number M 13-0237 MCCORMICK AND SCHMICK - 9404 EAST MARGINAL WAY S Dear JOE RONHAAR, Jim Haggerton, Mayor Jack Pace, Director This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the following departments: BUILDING DEPARTMENT: Dave Larson at 206-431-3678 if you have questions regarding these comments. • 1. The Quotation page 3 of 8 shows a 14 ft. 3 inch deep freezer that is 4 ft. 5 inches deeper than the adjoining cooler. The floor plan provided shows side by side coolers at the same depth. Please alter the incorrect plan to match as proposed. Note that if the wall behind the freezer is to be removed a Building permit is required. 2. Please provide anchorage details for the cooler and freezer. 3. The plan showing the location of the compressor needs more clarification as to its location and the cooler and freezer are shown as 11 ft. deep instead of 14ft. 3 inch and 9 ft. 10 inch. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a 'Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at 206-431-3655. Sincerely, Bill Rambo Permit Technician File No. M13-0237 6300 Southcenter Boulevard Suite #100 • Tukwila Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • • PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M13-0237 DATE: 03/19/14 PROJECT NAME: McCORMICK & SCHMICK_ SITE ADDRESS: 9404 EAST MARGINAL WAY S Original Plan Submittal X Response to Correction Letter # 2 Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: Building DivisionV-VA Public Works ❑ Fire Prevention Structural Planning Division ❑ Permit Coordinator PRELIMINARY REVIEW: Not Applicable (no approval/review required) DATE: 03/20/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/17/14 Approved n Approved with Conditions Corrections Required n Denied n (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: 12/18/2013 `PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M13-0237 DATE: 01/07/2014 PROJECT NAME: MCCORMICK & SCHMICK SITE ADDRESS: 9404 EAST MARGINAL WY S Original Plan Submittal X Response to Correction Letter # 1 Revision # Revision # before Permit Issued after Permit Issued DEPARTMENTS: 1,.Q 1-1,6-111 L tldmg 'vision Public Works Fire Prevention Structural ❑ Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ri (no approval/review required) DATE: 01/09/14 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Corrections Required (corrections entered in Reviews) DUE DATE: 02/06/14 Approved with Conditions ❑ Denied (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: t -1(r)-11-1 Bldg Nom- Fire ❑ Ping 0 PW 0 Staff Initials: 12/18/2013 rPERMIT COORD COPY • PLAN REVIEW/ROUTING SLIP PERMIT NUMBER: M13-0237 DATE: 12/24/13 PROJECT NAME: MCCORMICK AND SCHMICK SITE ADDRESS: 9404 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Revision # before Permit Issued Revision # after Permit Issued DEPARTMENTS: �L(1440i Building Division Public Works n pew1,1 ,I ire Prevention Structural Planning Division Permit Coordinator n PRELIMINARY REVIEW: Not Applicable ❑ (no approval/review required) DATE: 12/26/13 Structural Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 01/23/14 Approved ❑ Approved with Conditions Corrections Required ❑ Denied ❑ (corrections entered in Reviews) (ie: Zoning Issues) Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: L t LI Departments issued corrections: Bldg la. Fire ❑ Ping ❑ PW 0 Staff Initials: 12/18/2013 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: - — ['4C ' 7 Plan Check/Permit Number: ❑ Response to Incomplete Letter # ® Response to Correction Letter # ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Address: Contact Person: Isre e ce yio abc>e' Phone Number: ?fir ' g ? - 1324 Summary of Revision: ✓113- 0237 1/111u5evi4A d-Pit'Shf eoc,let< RECEIVED OF TIJIAAM.6 MAR 19 2014 PERAimegiovegt 4 /? y res fr 1Qrg ( v+ I e/v-u-/ r°4-41, S1-9 l%9 w h dodleF 41_04 /11--c.. A of c6 4--ag S • Sheet Number(s): rri — (� "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: VEntered in TRAKiT on 0S//1//c7 C:\Users\tenni(er-m\Desktop\Revision Submittal Form..doc City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov REVISION SUBMITTAL Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: V 7 / % / Plan Check/Permit Number: ❑ Response to Incomplete Letter # Response to Correction Letter # / ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner / -D,237 Project Name: 1/111 US t?voi c9-71-- Pt', ti V— d_m© ie tz re 104c e0- fei-e Project Address: 9 yOq ergs L W x/'9(1 (4- / w wry/ Contact Person: S r e ke yvi o /ddc2 v Phone Number: 2.0 6 - Q ( ? • (3 2 6 Summary of Revision: ../P/4 -c. Co frup /e 4- e cL rc,- w r ti 5 r -e "A (-4- l" 9 // p e q -e q ree / 4 d_cr) /e re 79y D v I - 2_,L9 0, a f•frl , Ott C'vvi, p/'rc-SoP2S .4 -4 Gi c )lith ewsl `- Po, e CITY OFTUKWM IJAN ;07 2014 °ERMn CENITEA Sheet Number(s): /, 0 / ,A. 1. 0 , J �• 0 d' • U � C� (, (, (� 2. (2 3 Uf a4/,, "Cloud" or highlight all areas of revision including date of rev•jsion Received at the City of Tukwila Permit Center by: ka—Entered in Permits Plus on H:\Applications\Forms-Applications On Line\2010 Applications\7-2010 - Revision Submittal.doc Reviced• May 2011 RESTAURANT REFRIGERATIONNRPR AWashington State Department of �,� Labor & Industries • Page 1 of 2 RESTAURANT REFRIGERATION & RPR Owner or tradesperson RONHAAR, JOSEPH DANIEL Principals RONHAAR, JOSEPH DANIEL WA UBI No. 602 604 020 1726 STANWOOD-BRYANT RD ARLINGTON, WA98223 425-387-7990 SNOHOMISH County Business type Individual License Verify the contractor's active registration / license / certification (depending on trade) and any past violations. Construction Contractor License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. RESTARR883OE Effective — expiration 09/05/2012 — 09/05/2014 Bond American Contractors Indem CO Bond account no. 100204356 Received by L&I 09/05/2012 Active. Meets current requirements. $6,000.00 Effective date 08/28/2012 httns://secure.lni.wa.2ov/verify/Detail.aspx?UBI=602604020&LIC=RESTARR883OE&SAW= 03/31/2014 INSULATED CEILING PANEL POWER SUPPLY & FIELD WIRING BY ELECTRICIAN HOT - NEUTRAL SWITCH LEG - GROUND BLACK WHITE RED GREEN CONDUIT STUB.OUT THRU WALL (INSIDE) INSULATED WALL PANEL WEATHERPROOF SWITCH & pILQT LIGHT, FLUSH MTD, LIGHT SWITCH FOAM RAIL HEATER CABLE ON (3) BIDES OF DOOR OPENING (FRZ ONLY) DETAIL L DOOR JAMB ADJUSTABLE DOOR SWEEP WI NEOPRENE WIPERS THRESHOLD COVER 01 HEATER WIRE CONCRETE SLAB INTERIOR RAMP INTERIOR EXTERIOR • a4 A 2 4. DETAIL et FLUSH MOUNT DOOR WITH INTERIOR RAMP FREEZER DOOR SILL INSULATED DOOR PANEL DOOR SILL FACTORY INSTALLED TRIM CAP (STD.) CAM -LOCK WALLS TO CEILING frgi Iii INSULATED CEILING PANEL INSULATED WALL PANEL TOP OF COMPARTMENT CEILING CLOSURE PANEL (REMOVABLE FOAM RAIL INSULATED WALL PANEL COVE BASE - NSF (T0 MATCH WALL) CONC. SLAB (BY OTHERS) INTERIOR EXTERIOR WALL PANELS SET ON CONT. CALV. STL. TRACK, ANCHORED TO FLR. W/ DRIVE PINS (14 24" O.C. WALL NO FLOOR FOAM RAIL 4 COVE BASE - NSF (TO MATCH WALL) INSULATED FLOOR PANEL WITH INTEGRATED 3/8' RADIUS NSF COVE (STANDARD) W/ PLYWOOD REINF. CONC. SLAB (BY OTHERS) DETAIL al STANDARD FLOOR • LOCK TO WALLS FOAM RAIL INSULATED WALL PANEL WALL CLOSURE 1'X8' MATCH WALL FINISH BUILDING WALL TAIR SPACE (MIN) PLAN VIEW • CLOSURE TRIM(1 X8) FOAM RAIL INSULATED WALL PANEL 21/2'x21/2'x4 1/2' LONG ANGLE CLIP (2)1 1/2' 610 PAN HEAD SCREW INTO IN6UL, INTO STUD (2)1/4" 1 1/2' EXPANSION BOLT ANGLE CLIP SPECIAL ANGLE CLIPS USE: 21/2"x21/7x41/2"LONG ANGLE CUPS SEAM IN PANELS (2)112" 610 PAN HEAD SCREW (2)114' x 11/7 EXPANSION BOLT ANGLE CLIP (2)11/2" 610 PAN HEAD SCREW EXISTING S' CONC, SLAB 41/2" 11 (2)1/4"x 11/2' EXPANSION BOLT ANGLE CLIP 11 1 1 ll 11 11 i J i i i J 11 i 11 11 11 11 11 Sizes - 2121116' to 240' Sizes-1641116'to 212' Sizes -1161116' to 164' /E: 0 LL 24'-0" [288.000] 14'-0" [ 168.000] 10'-0" [120.000] r1 O 0 O 06 LJ 0 Q O 2'-2 1 /8" CRO2 \ \ \ \ 3'-11" W03 \ \ \ \ \ \ \ \ 3'-11" W03 law 3'-1 1" W03 1'-9 1 /4" CRO5 3'-11" 3'-1 1" W06 W06 L P L P L \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ 1 T w M T C) r r P L P L P L P P L L i -y u Jp TI O O O O r1 O O O N 0) LJ rn T U L 3'-0 3/8" 35°F Holding cpoler 4" walls, 4" ceiling, floorliss 96" high, foam rail, lock walls to coiling Int: Galvanized/Embossed Whit - 26 Ga. Ext: Galvanized/Embosse1- 26 Ga. 36"W x 78"H FODO1 • 3'-1 1" 3'-1 1" 1 N U PCL P P L U L() cb C) Co CV) 2'-11 5/8" L P L L -10°F Holding freezer 4" walls, 4" ceiling, 4" floor 96" high, foam rail, lock walls to ceiling Lock walls to floor - - -1•At -Ga aiized/E-•r bessed4W e -26 -Ga,- - Ext: Galvanized/Embossed - 26 Ga. 00 Floor int: Aluminum/Smooth - .050 U Floor ext: Galvanized/Embossed - 26 Ga. O) O 0 3'-1 7/8" P 36-"W x -7811 - FO D02 P P 24" Rarip W02 J01 WO1 W00 T01 COOLER/FREEZER PLAN FoL 3'-11" J02 3'-0 3/8" P CRO3 FRONT ELEVATION CO T T 1 CV co O • \ \ T \ r M • \ \\\\\•\•v\\\y (O O \ \ N• \ \ I f-1 O O O 06 l 0 I-1 O O O 0) LJ O PROJECT NAME _..-.._ Boeing...... PROJECT# 17004601 J01 DOOR C1 COOLER OR FREEZER COOLER (9569,71112486 ,5 btu) WAL FRAMNG MATERIAL WALL THICKNESS TYPE OF FLOOR FLOOR THICKNESS' TYPE OF RMP RAMP DEPTH TILE & GROUT THICKNESS COM PARTMair RMATIONIMININIEVEMESSIMEMENNUSSNEMESISS �E L=OAM 4,0000 NONE •JAMB CONSTRUCTION IRFORMATION alliSMOVENEMOSSEIMINIONEEN. EXTERIOR FINISH INTERIOR FINISH OPENING HEIGHT_ OPENING VMDTH OPENING TYPE GALVANIZED/BYPASSED- 26 GA GA-VANIZED/EMBOSSED WHITE- 26 GA 78.0000 HEADER HEIGHT 138759 FRAME HEIGHT 91.8750 38.0000 LEFT JAWS WIDTH 55000 FRAME WIDTH 47.0000 SC OVERLAP RIGHT JANBWIDTH 5.5000 FRAYETHICKNESS 4.0000 - DOORCONSTRUCIION INF3RMATIONIENSIMENSEMOMMENSIMMISSIMMEN EXTERIOR FINISH INTERIOR FINISH EXTERIOR PAN HEIGHT' EXTERIOR PAN W DTH PAN THICKNESS HINGE POSITION (SWING) DRAGGER PAN FRAMNG MATERIAL GASKET TYPE GPLVANIZED/Et BOSSED- 26 GA GCLVANIZFD/EMSO D VtHITE • 28 GA, 78.2500 380000 4.0090 LEFT ADJUSTABLE SWEEP OiVEGA MAGNETIC 5pwmgtFitJS17NGitfi Rd1ATi0N =- - ITEM JAMB GUARD LATCH/STRIKE INSIDE RELEASE HINGE(TOF2 -HINGE (MJDDLEI HINGE(BOTTOM) DOOR CLOSER TYPEORM00E L 1 .K58/59 K.481A K-1248 K-1248 K-1094 ffal SWITCH (wl"J" BOXj UGHT /MOUNTED BASE) PRESSURE RELIEF PORT THERMOMETER TEMPERATURE ALARM FAN CUTOFF SWITCH JUNCTION BOX NEWPORT 1 HEATER WIRE LOCKING BAR STRIP CURTAIN KICKPLATES NAME PLATE po_oR /UWE Al-CIESSORIESIfillfififtlIWWWWWWWAIlltfilfillIfillfillrellFIWWWWIWFIF TYPEORMODB. J,OCAT1ON )iBQfrA.F.F Riot Li¢' Snitch 120v _ ..... w/cooer(loose). for 2x4 nosh Rr3HTjos handy box (stub condut to box 'on hterior) 21/2"DIAL HUM EXT LEFTJAMB: EXT NON -HEATED 14'X14 BOOR PAN PROJECTNAME Boeing PROJECT# 170046.01 JAMB ftJ02 POOR fL... CO2 _. - COOLER OR FREEZER FRFP7FR (9782.56113677 btu) CROWN DOOR PAN Gavin]'° k TCOMPARTME4TINFORMATIONFiregt WALL FRAMNG MATERIA. WALLTHICKNESS TYPE OF FLOOR FLOOR THICKNESS TYPE OF RAMP -RAMP DEPTH TILE & GROUT THICKNESS PGAM 4,0000 _._. STANDARD 4.0000 INTERIOR 240000 JA MB. CONSTRUCTIONINFORM AT1ON _ _ EXTERIOR FINISH INTERIOR FINISH OPENING HEIGHT OPENING WDTH OPENING TYPE GA.VANIZED/Eh OSSED-26GA GA.VANIZED/EtoDOSEDY(HIT E • 25 GA. 78.5000 HEATRHEIGHT 13.2500 FRAME HEIGHT 91.7500 389000 LEFTJAJBYNDTH 55090 FRA+E'AADTH X47.9000 -SC 01-ERLAoRIG-HT JAMS WIDTH 55000 'PRAYETHICKNESS .45000 - coOR CONSTftionoN NFORmATION "asstru " EXTERIOR FINISH INTERIOR FINISH EXTERIOR PAN HEIGHT EXTERIOR PAN WDTH PAN THICKNESS HINGE POSITION (SW NG) DRAGGER PAN FRAMING MATERIAL GASKET TYPE GALVANIZED/EMt3OSSED- 28 GA GALVANIZED/EtIBOSSEO WHITE 28 GA. 782500 38.0000 4.09 RIGHT ADJUSTABLE SWEEP . OMEGA MAGNETIC HEATiN DOOR BOTTOM HARPWAREJ FlNSHNG WFORLIATION -- lam_ JAMB GU ARD LATCH! STRIKE INSIDE RELEASE HiNGE(rMP!___ HINGE (MIDDLE) HINGE (BOTTOM) DOOR CLOSER TYPE K.58/59 K.487A <-1248 1 ._1.K-1248 __.._.._.._....___. 1__ x1094 MOTE. DOOR tUAMB ACCESSORIES LTA SIMTCH (W/"J" 60X1 LIGHT /MOUNTED BASE) PRESSURE RELIEF PORT THERMOMETER TEMPERATURE ALARM FAN CUTOFF SWITCH JUNCTION BOX VIEW PORT HEATER WIRE LOCKING BAR ....._.... STRIP CURTAIN KICKPLATES NANE PLATE gjy TYPEORMOD3, LOCATION )BGHTA,FF INT/EXT: Piot Light 5wtch 120v 1 w/cover(loose),for2x4flush LEFT JANS handy box (stub condutto bow on hterior) 1 K-1832(HEATED) HEADER 21/2 DIAL R1G4TJAb13 HEATED 14"X14" 3 -SIDED 1 CROWN Exr DOOR PAN JAMB HEADER MT Project: Boeing Quote # 170046.01 Crown lt ka 1 WAur•INS It Date: 09/21/2011 Originator: VIrglnla Davis Re vision: i6 -11/05/2013 QTY �d ,. 9 Ceilings 5 : �_ I 6 (V THERMOMETER glig ---nni-Al DROVE © SOCRUMTED MOW REIM PS PLOTLIGHTSWITCH PSS MAYKOWNIDI 6:1 TRUSHano:1000xFoo L II • • . • •' BUBBLES Jambs ...• • II d 16 # ) . .•' 1 36" X78" KASON STRP CURTAIN FOR FREEZER ONLY . . . : - -= I , O ■I o O _. I■'I . . • tam .. . .. . .. . .. • .. . .. • .. • .. . ._. .• 1 ( • • . . . • . • • . . =CDR PIN NOTATIONS FJXT(lRES . .. .,. , •. . •... .. • Light- 1806 (120v) Vapor -Proof Compact Fluorescent Globe fixture w/bulb (Ship Loose) . . • Pilot Light Switch 120e w/cover(loose), tor2x4 flush handy box _ . lc, tETALREEFO1111681 (SECTION) 2 SPECIAL BRACKET M ROOM NNE FRONT ELEVATION CO T T 1 CV co O • \ \ T \ r M • \ \\\\\•\•v\\\y (O O \ \ N• \ \ I f-1 O O O 06 l 0 I-1 O O O 0) LJ O PROJECT NAME _..-.._ Boeing...... PROJECT# 17004601 J01 DOOR C1 COOLER OR FREEZER COOLER (9569,71112486 ,5 btu) WAL FRAMNG MATERIAL WALL THICKNESS TYPE OF FLOOR FLOOR THICKNESS' TYPE OF RMP RAMP DEPTH TILE & GROUT THICKNESS COM PARTMair RMATIONIMININIEVEMESSIMEMENNUSSNEMESISS �E L=OAM 4,0000 NONE •JAMB CONSTRUCTION IRFORMATION alliSMOVENEMOSSEIMINIONEEN. EXTERIOR FINISH INTERIOR FINISH OPENING HEIGHT_ OPENING VMDTH OPENING TYPE GALVANIZED/BYPASSED- 26 GA GA-VANIZED/EMBOSSED WHITE- 26 GA 78.0000 HEADER HEIGHT 138759 FRAME HEIGHT 91.8750 38.0000 LEFT JAWS WIDTH 55000 FRAME WIDTH 47.0000 SC OVERLAP RIGHT JANBWIDTH 5.5000 FRAYETHICKNESS 4.0000 - DOORCONSTRUCIION INF3RMATIONIENSIMENSEMOMMENSIMMISSIMMEN EXTERIOR FINISH INTERIOR FINISH EXTERIOR PAN HEIGHT' EXTERIOR PAN W DTH PAN THICKNESS HINGE POSITION (SWING) DRAGGER PAN FRAMNG MATERIAL GASKET TYPE GPLVANIZED/Et BOSSED- 26 GA GCLVANIZFD/EMSO D VtHITE • 28 GA, 78.2500 380000 4.0090 LEFT ADJUSTABLE SWEEP OiVEGA MAGNETIC 5pwmgtFitJS17NGitfi Rd1ATi0N =- - ITEM JAMB GUARD LATCH/STRIKE INSIDE RELEASE HINGE(TOF2 -HINGE (MJDDLEI HINGE(BOTTOM) DOOR CLOSER TYPEORM00E L 1 .K58/59 K.481A K-1248 K-1248 K-1094 ffal SWITCH (wl"J" BOXj UGHT /MOUNTED BASE) PRESSURE RELIEF PORT THERMOMETER TEMPERATURE ALARM FAN CUTOFF SWITCH JUNCTION BOX NEWPORT 1 HEATER WIRE LOCKING BAR STRIP CURTAIN KICKPLATES NAME PLATE po_oR /UWE Al-CIESSORIESIfillfififtlIWWWWWWWAIlltfilfillIfillfillrellFIWWWWIWFIF TYPEORMODB. J,OCAT1ON )iBQfrA.F.F Riot Li¢' Snitch 120v _ ..... w/cooer(loose). for 2x4 nosh Rr3HTjos handy box (stub condut to box 'on hterior) 21/2"DIAL HUM EXT LEFTJAMB: EXT NON -HEATED 14'X14 BOOR PAN PROJECTNAME Boeing PROJECT# 170046.01 JAMB ftJ02 POOR fL... CO2 _. - COOLER OR FREEZER FRFP7FR (9782.56113677 btu) CROWN DOOR PAN Gavin]'° k TCOMPARTME4TINFORMATIONFiregt WALL FRAMNG MATERIA. WALLTHICKNESS TYPE OF FLOOR FLOOR THICKNESS TYPE OF RAMP -RAMP DEPTH TILE & GROUT THICKNESS PGAM 4,0000 _._. STANDARD 4.0000 INTERIOR 240000 JA MB. CONSTRUCTIONINFORM AT1ON _ _ EXTERIOR FINISH INTERIOR FINISH OPENING HEIGHT OPENING WDTH OPENING TYPE GA.VANIZED/Eh OSSED-26GA GA.VANIZED/EtoDOSEDY(HIT E • 25 GA. 78.5000 HEATRHEIGHT 13.2500 FRAME HEIGHT 91.7500 389000 LEFTJAJBYNDTH 55090 FRA+E'AADTH X47.9000 -SC 01-ERLAoRIG-HT JAMS WIDTH 55000 'PRAYETHICKNESS .45000 - coOR CONSTftionoN NFORmATION "asstru " EXTERIOR FINISH INTERIOR FINISH EXTERIOR PAN HEIGHT EXTERIOR PAN WDTH PAN THICKNESS HINGE POSITION (SW NG) DRAGGER PAN FRAMING MATERIAL GASKET TYPE GALVANIZED/EMt3OSSED- 28 GA GALVANIZED/EtIBOSSEO WHITE 28 GA. 782500 38.0000 4.09 RIGHT ADJUSTABLE SWEEP . OMEGA MAGNETIC HEATiN DOOR BOTTOM HARPWAREJ FlNSHNG WFORLIATION -- lam_ JAMB GU ARD LATCH! STRIKE INSIDE RELEASE HiNGE(rMP!___ HINGE (MIDDLE) HINGE (BOTTOM) DOOR CLOSER TYPE K.58/59 K.487A <-1248 1 ._1.K-1248 __.._.._.._....___. 1__ x1094 MOTE. DOOR tUAMB ACCESSORIES LTA SIMTCH (W/"J" 60X1 LIGHT /MOUNTED BASE) PRESSURE RELIEF PORT THERMOMETER TEMPERATURE ALARM FAN CUTOFF SWITCH JUNCTION BOX VIEW PORT HEATER WIRE LOCKING BAR ....._.... STRIP CURTAIN KICKPLATES NANE PLATE gjy TYPEORMOD3, LOCATION )BGHTA,FF INT/EXT: Piot Light 5wtch 120v 1 w/cover(loose),for2x4flush LEFT JANS handy box (stub condutto bow on hterior) 1 K-1832(HEATED) HEADER 21/2 DIAL R1G4TJAb13 HEATED 14"X14" 3 -SIDED 1 CROWN Exr DOOR PAN JAMB HEADER MT Project: Boeing Quote # 170046.01 Crown lt ka 1 WAur•INS Customer.REHJBROOKE REFRIGERATION Date: 09/21/2011 Originator: VIrglnla Davis Re vision: i6 -11/05/2013 QTY SENT Items shipped loose 9 Ceilings 5 Comers 2 Doors 6 (V THERMOMETER glig ---nni-Al DROVE © SOCRUMTED MOW REIM PS PLOTLIGHTSWITCH PSS MAYKOWNIDI 6:1 TRUSHano:1000xFoo Floors 2 BUBBLES Jambs 2 ALL PANEL BUBBLES SHOWN WILL MATCH THE CORRESPONDING FINISH COLOR (SEE MATTO LEFT) DETERIREIKTERM'coom"%6PANacaraWILL T -Watts 16 # ) Walls ANCILLARIES 1 36" X78" KASON STRP CURTAIN FOR FREEZER ONLY ' 0002 HARD ARE IIND ACCESSORIES .. 4 Jamb Stability Brackets (2x3 L -Shaped) 1 ( THRESHOLD- NON HEATED =CDR PIN NOTATIONS FJXT(lRES . .. .,. , 6 Light- 1806 (120v) Vapor -Proof Compact Fluorescent Globe fixture w/bulb (Ship Loose) 2 Pilot Light Switch 120e w/cover(loose), tor2x4 flush handy box _ . lc, tETALREEFO1111681 (SECTION) 2 SPECIAL BRACKET M ROOM NNE (stub conduit to box on interior) GENERAL 1 Box Prints 1 03)006.00 WIFE 01 Installation Manual m mi PAIL SUPPLIES .: 1 Cam -Lock Wrench 23 Caulk - Butyl (Tubes ) 18 Snap Plugs 1/T (Grey) 10 Snap Plugs 1/T (Grey) (spare) 171 Snap Plugs 1/2" (White) 25 Snap Plugs 1/2" (White) (spare) 1 Touch Up Pamt - White WALL TD FLOOR AND WALL TO CEILING COlri1ECT(ONS 5 Alignment Stnps For Foam Rail (96") BUYOUTS lonty 1? shkpped from manufacturing.plant) . _,. .. . Refrigeration Equipment 1 MOH015X83CFMT with Defrost timer, Drier, Sight glass and Shutoff valve installed w/(1) LCA6135AEB coil with expansion valve solenoid and themlostat shipped loose ECM fan motors 35T R404 208-230/3/60 1 MOZ035L63C with Defrost timer, Cner, Sight Dass and Shutoff valve installed w/(1) LCE6140BEB coil with expansion valve solenoid and thermostat mounded ECM fan motors -10°F R404 208-230/3/60 I 1 1 1 1 1 1 1 SPECIFICATION: APPROVED BY: NSF. CONSTRUCTION - 4" HARD NOSE TONGUE & GROOVE HIGH DENSITY URETHANE PERIMETER (CFC FREE) W/ SHT, MTL, FACING FLANGED 1/2" TO 3/4' PERIMETER OF EACH SHEET. CORNERS & T PANELS ONE-PIECE CONSTRUCTION W/ 1/2" RADIUS AT ALL INSIDE VERTICAL CORNERS. JOINTS SEALED W/ PVC GASKET AT INT. & EXT. PERIMETER OF PANELS. PANELS RIGID CONNECTION W/ CAM -LOCK FASTENERS (WALL TO WALL: 46" O.C, MAX,: WALL TO CEILING; 24" O.C. MAX,; WALL TO FLOOR:24" O,C. MAX., IF APPLY) INSULATION - 4" THICK FOAMED IN PLACE HIGH DENSITY URETHANE (CFC FREE) FILLED, OVER 90 PERCENT CLOSED CELL CONTENT. LESS THAN 25 FLAME SPREAD IN ACCORD W/ UBC STD. 42-1 (BASED ON UL 723 WHICH IS SIMILAR TO ASTM ES4 THE STEINER TUNNEL TEST) AND CLASS "A" INTERIOR FINISH IN ACCORDANCE W/ NFPA 101, SECTION 6-2, AND NFPA 255. K -FACTOR NOT TO EXCEED 0.14 BTU/HOUR/SQ, FT./°F PER INCH THICKNESS IN ACCORDANCE W/ ASTM C177 AT 75 °F MEAN TEMPERATURE. thermalrite IS iN COMPLETE COMPLIANCE WITH THE FEDERAL ENERGY STANDARD : AS OUTLINED IN HR 6-74 PARAGRAPH 1-C (R -VALUE R-25 COOLER & R-32 FREEZER) Box description: Coder/Freezer Combo Dimensions: External (O.D.):24'0"x14'3"x8'0"-wxdxh Internal(LD,): 23'4"x 13'7"x7'8"-wxdxh Volume: 2430 ft' Finishes Walls: Galvanized/Embossed White - 26 Ga. - interior Galvanized/Embossed - 26 Ga, - exterior Floors: Aluminum/Smooth - .050 - interior Galvanized/Embossed - 26 Ga. - exterior Ceilings: Galvanized/Embossed White - 26 Ga. - interior Galvanized/Embossed - 26 Ga. - exterior Panel Thickness Walls: Floors: Ceilings: 4" UL Listed Class 1 Foam 4" UL Listed Class 1 Foam standard floor 1000 Ib/ft2 equally distributed (single layer of underlayment in floor) 4" UL Listed Class 1 Foam Qoors 001: 1 Finished opening 36" x 78" hinged self close overlap cooler door 1 Viewpod- Unheated 14'5t14" 1 Latch- Kason 58CL Cylinder Locking -W/59 Roller Strike (Set Closing) 1 Pilot Light Snitch 120v w/cover0o0se), for 2x4 flush handy box (stub conduit to box on Interior) 1 Thermometer 2 1/2' Dial vdth Standard Lead 1 Door Closer- Kason 1094 SureClose'" Hydraulic (Concealed mounting) 1 Gasket- Magnetic D02: 1 Finished opening 36' x 78" hinged self dose overlap freezer door 1 Viewport-120v Heated 14"x14' 1 Ramp/24" Deep, interior 1 Latch- Kason 58CL Cylinder Locking -W/59 Roller Strike (Sef Closing) 1 Threshold- Non heated 1 Pilot Light Svdch 120v w/coverdoose), for 2x4 flush handy box (stub conduit to box on Interior) 1 Thermometer 212' Dial with Standard Lead 1 Heated Jamb, NO Threshold heat 1 Heat in Bolton Of Door 1 Door Closer- Kason 1094 SureCloseTM Hydraulic (Concealed mounding) 1 Gasket- Magnetic Qty Description Qty Description Accessories 6 Light- 1806 (120v) Vapor -Proof Compact Fluorescent Globe fixture vubulb (Ship Loose) 23 Lock Wall Panels to Floor Panels 45 Lock Wall Panels to Ceiling Panels (Factory Ceiling Caps - Standard) 1 MOZ035L63C with Defrost timer, Drier, Sight glass and Shutoff valve installed W(1) LCE6140BEB cod with expanson valve solenoid and theimostat mounted motors -10T R404 208-230/3/60 Freight /allowed ECM fan Miscellaneous 1 36" X 78' Kason Strip Curtain for Freezer ordy Refrigeration Condensing UM for Holding cooler • Manufacturer, • Description: • Model: • Horsepower: • Extras: • Electrical: • Conditions: • Waranty: 1 x Evaporator (Unit cooler) • Manufacturer • Descdpdon: • Model: • Extras: • Electrical: Condensing Wit for Holding • Manufacturer: • Descdpdon: • Model: • Horsepower: • Extras: • Electrical: • Conditions: • Wendy: 1 x Evaporator (Untt cooter) • Manufacturer. • Description: • Model: • eras: • Electrical: 1 Vert - 115v HI -Flow Heated Pressure Relief Pod (Kason 1832) 23 Caulk- Butyl (Tubes) 1 Blocking For Strip Curtain 1 MOH015X63CCFMT w!h Defrost timer, Drier, Sight glass and Shutoff valve installed w/(1) LCA6135AEB coil with eansion valve solenoid and thermostat ose ECM fan motors 35"F R404 208.230/3/60 Freed allowed Headers! Med Temp R404A Air CTed Hermetic Remote Outdoor Condensing Urn! with microchannei condenser M011015X63CFMT 1,5hp Defrost timer, Drier, Sight glass and Stxrtoff valve installed 208.230!6/60, RLA 6,7, MOPO 15, RSA 15 STUN: 13960 Room Temp: 35"F Ambient: 95T Compressor -motor warranty extended to 5 -years, pads only, no labor Heatcrat Alr defrost Low profile coil (unit cooler) 115/1/60 with EC fan motors colt LCA6135AEB with expansion valve solenoid and thermostat shipped loose ECM fan motors 115/1/60, Fan amps 2.9, Defrost amps N/A freezer Healcraft Low Temp R404A Air Cooled Scroll Remote Outdoor Condensing Unit with m icrcchannel condenser end energy saving Smart Defrost MOZ035163C 3hp Defrost Omer, Drier, Sight glass and Shutoff valve Installed 208-230/3/60, RLA 12.2, MOPO 30, MCA 29 BTUH: 12900 Room Tempt -10'F Ambient: 95"F Compressor -motor warranty extended to 6 -years, pads only, no labor Heatcral Electric defrost Low profile coil (unit cooler) 208-230/1/60 With EC fan motors coil LCE614OBEB with expansion valve solenoid end thermostat mutated ECM fan motors 208-230/1/60, Fan amps 1.6. Defrost amps 11.7 rJ No. It 042:11 Pe Pian; review approval is subject to errors and omissions. of con truction documents does not stuthol"ize tat on of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowled t ed:, By Date: 3/o /lel City Of Tukwila BUILDING DIVISION CORRECTION LTR# Z M13- 0237 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 2 0 2014 City of Tukwila BUILDING DIVISION; RECEIVED CITY OF TUKWILA MAR 1 9 2014 PERMIT CENTER DRAWING AND SPECIFICATION ARE TO BE USED FOR APPROVAL PURPOSES AND SHOULD NOT BE USED FOR INSTALLATION,ASSEMBLY DRAWINGS WILL BE SENT WITH FINAL SHIPMENT. WARNINGS: TO AVOID DOOR GASKET DAMAGE: DO NOT ENERGIZE FRFF7FR DOOR HEATERS PRIOR TO STARTUP OF REFRIGERATION TO AVOID DISCOLORATION OF METAL ON PANELS: PROPERLY VENTILATE EACH ROOM IF TILE OR MASONRY WORK IS TO BE DONE COMPLIANCE WALK-INS MEET OR EXCEED ALL PRESCRIPTIVE STANDARDS OF THE ENERGY INDEPENDENCE ACT AND SECURITY ACT OF 2007 (H.R,B) ELECTRICAL NOTICE ALL ELECTRICAL COMPONENTS WITHIN THE WALK-iNS. I.E. LIGHT SWITCHES, PRESSURE RELIEF PORTS, JAMB HEATERS SHALL BE FACTORY PRE -WIRED, FOR HOOK UP BY ELECTRICAL CONTRACTOR. ALL LIGHT FIXTURES SUPPLIED ARE SHIPPED LOOSE FOR INSTALLATIONS BY ELECTRICAL CONTRACTOR. ThermalRite SHALL ACCEPT NO RESPONSIBILITY FOR ANY BACK CHARGES ASSOCIATED WITH INSTALLATION OF LIGHT FIXTURES OR FIELD WIRING CONNECTIONS. CONSTRUCTION (STANDARD) W/ SHEET METAL FACING FLANGED " PERIMETER OF EACH SHEET. CORNERS AND T -WALLS ONE PIECE CONSTRUCTION W/1" RADIUS AT ALL INSIDE VERTICAL CORNERS, JOINTS SEALED W/ PVC GASKET AT INT. & EXT, PERIMETER OF PANELS, CONNECTED W/ CAM -LOCK FASTENERS. INSULATION (STANDARD) FOAMED IN PLACE, OVER 90 PERCENT CLOSED CELL CONTENT, LESS THAN 25 FLAME SPREAD IN ACCORD WITH UBC STANDARD 42-1 (BASED ON UL 723 WHICH IS SIMILAR TO ASTM -E84 THE STEINER TUNNEL TEST) AND CLASS "A" INTERIOR FINISH IN ACCORDANCE WITH NEPA 101 SECTION 6-2 AND NEPA 255. K-EACTOR NOT TO EXCEED 0.14 BTU/HOUR/FT2F PER INCH THICKNESS IN ACCORDANCE W/ ASTM C177 AT 55° F MEAN TEMPERATURE. SITE NOTATION • WHEN APPLICABLE - DOES BUILDING FLOOR HAVE TILE AND GROUT INSTALLED BEFORE OR AFTER WALK-IN INSTAUATION IF SO PROVIDE TILE THICKNESS FREEZER MINIMUM AIR SPACE ALL AROUND WALK-IN FOR AMPLE AIR CIRCULATION 2 lege% 0197 Svo 3 REV DESCRIPTION DATE BY Manufacturer Information Crown k 4215 E. AIRPOWRTALDRK. 'MS ONTARIO, CA, 91761 PHONE (909) 605-6419 FAX (909) 605-6413 PLEASE NOTE DUE TO THE POSSIBLE ERROR OF INTERPETATION PLEASE BE CERTAIN TO CAREFULLY REVIEW ALL ASPECTS OF THE DRAWING BEFORE MARKING AS 'APPROVED' FOR PRODUCTION RELEASE. Approval Status Block Drawing Reviewed By: Review Date: Please Check Appropriate Field Approved as Drawn: Approved with Changes Revise and Resubmit: Customer Service Rep. VD Submittal Drafter Shop Drafter JS FL Scale Project SqFt 343 Save Dwg Date: 12.02.13 Customer/Dealer REHN BROOKE REFRIGERATION 17223 MOUNTAIN VIEW RD SE MONROE, WA. 98272 Site Information REHN BROOKE REFRIGERATION SEATTLE, WA. 98134 Sheet # 1 of 1 Create Dwg Date: 12.02.13 Project # SYMBOLS METAL FINISHES (V THERMOMETER glig ---nni-Al DROVE © SOCRUMTED MOW REIM PS PLOTLIGHTSWITCH PSS MAYKOWNIDI 6:1 TRUSHano:1000xFoo PANEL BUBBLES ESMOOTH GALVANIZED STUCCOGALVANIZED STUCCO ALUMINUM STUCCO WHITE GALV. SMOOTH ALUMINUM sSMTAIOONTHLEWsHsITSETGEALEVL: GLASS BOARD (FRP) I PANEL BUBBLE NOTE ALL PANEL BUBBLES SHOWN WILL MATCH THE CORRESPONDING FINISH COLOR (SEE MATTO LEFT) DETERIREIKTERM'coom"%6PANacaraWILL WALL PANEL WAIIPMELWITH FLOORPANEL CETUNG PANEL SILL PANEL WAN DOORJA1.5 HEVERIRMINESS ( # ) ( •cL) ( =CDR PIN NOTATIONS JAMB GUARDS x 0 LOCK (FLOORS) 0 PIN (FLOORS) _ . lc, tETALREEFO1111681 (SECTION) 2 SPECIAL BRACKET M ROOM NNE s 03)006.00 WIFE 01 m mi DRAWING AND SPECIFICATION ARE TO BE USED FOR APPROVAL PURPOSES AND SHOULD NOT BE USED FOR INSTALLATION,ASSEMBLY DRAWINGS WILL BE SENT WITH FINAL SHIPMENT. WARNINGS: TO AVOID DOOR GASKET DAMAGE: DO NOT ENERGIZE FRFF7FR DOOR HEATERS PRIOR TO STARTUP OF REFRIGERATION TO AVOID DISCOLORATION OF METAL ON PANELS: PROPERLY VENTILATE EACH ROOM IF TILE OR MASONRY WORK IS TO BE DONE COMPLIANCE WALK-INS MEET OR EXCEED ALL PRESCRIPTIVE STANDARDS OF THE ENERGY INDEPENDENCE ACT AND SECURITY ACT OF 2007 (H.R,B) ELECTRICAL NOTICE ALL ELECTRICAL COMPONENTS WITHIN THE WALK-iNS. I.E. LIGHT SWITCHES, PRESSURE RELIEF PORTS, JAMB HEATERS SHALL BE FACTORY PRE -WIRED, FOR HOOK UP BY ELECTRICAL CONTRACTOR. ALL LIGHT FIXTURES SUPPLIED ARE SHIPPED LOOSE FOR INSTALLATIONS BY ELECTRICAL CONTRACTOR. ThermalRite SHALL ACCEPT NO RESPONSIBILITY FOR ANY BACK CHARGES ASSOCIATED WITH INSTALLATION OF LIGHT FIXTURES OR FIELD WIRING CONNECTIONS. CONSTRUCTION (STANDARD) W/ SHEET METAL FACING FLANGED " PERIMETER OF EACH SHEET. CORNERS AND T -WALLS ONE PIECE CONSTRUCTION W/1" RADIUS AT ALL INSIDE VERTICAL CORNERS, JOINTS SEALED W/ PVC GASKET AT INT. & EXT, PERIMETER OF PANELS, CONNECTED W/ CAM -LOCK FASTENERS. INSULATION (STANDARD) FOAMED IN PLACE, OVER 90 PERCENT CLOSED CELL CONTENT, LESS THAN 25 FLAME SPREAD IN ACCORD WITH UBC STANDARD 42-1 (BASED ON UL 723 WHICH IS SIMILAR TO ASTM -E84 THE STEINER TUNNEL TEST) AND CLASS "A" INTERIOR FINISH IN ACCORDANCE WITH NEPA 101 SECTION 6-2 AND NEPA 255. K-EACTOR NOT TO EXCEED 0.14 BTU/HOUR/FT2F PER INCH THICKNESS IN ACCORDANCE W/ ASTM C177 AT 55° F MEAN TEMPERATURE. SITE NOTATION • WHEN APPLICABLE - DOES BUILDING FLOOR HAVE TILE AND GROUT INSTALLED BEFORE OR AFTER WALK-IN INSTAUATION IF SO PROVIDE TILE THICKNESS FREEZER MINIMUM AIR SPACE ALL AROUND WALK-IN FOR AMPLE AIR CIRCULATION 2 lege% 0197 Svo 3 REV DESCRIPTION DATE BY Manufacturer Information Crown k 4215 E. AIRPOWRTALDRK. 'MS ONTARIO, CA, 91761 PHONE (909) 605-6419 FAX (909) 605-6413 PLEASE NOTE DUE TO THE POSSIBLE ERROR OF INTERPETATION PLEASE BE CERTAIN TO CAREFULLY REVIEW ALL ASPECTS OF THE DRAWING BEFORE MARKING AS 'APPROVED' FOR PRODUCTION RELEASE. Approval Status Block Drawing Reviewed By: Review Date: Please Check Appropriate Field Approved as Drawn: Approved with Changes Revise and Resubmit: Customer Service Rep. VD Submittal Drafter Shop Drafter JS FL Scale Project SqFt 343 Save Dwg Date: 12.02.13 Customer/Dealer REHN BROOKE REFRIGERATION 17223 MOUNTAIN VIEW RD SE MONROE, WA. 98272 Site Information REHN BROOKE REFRIGERATION SEATTLE, WA. 98134 Sheet # 1 of 1 Create Dwg Date: 12.02.13 Project #