Loading...
HomeMy WebLinkAboutPermit M13-043 - NGUYEN RESIDENCE - ALTERATIONNGUYEN RESIDENCE 12055 44 AV S M13-043 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 3347400420 Address: 12055 44 AV S TUKW Project Name: NGUYEN RESIDENCE Permit Number: M13-043 Issue Date: 08/07/2013 Permit Expires On: 02/03/2014 Owner: Name: NGUYEN THANH D Address: 12055 44TH AVE S , SEATTLE WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Email: SHARYN.PARKER@KINGCOUNTY.GOV Contractor: Name: S K M CONSTRUCTION INC Address: 14415 SE 143 PL , RENTON, WA 98059 Contractor License No: SKMCOI*052L3 Phone: 206-296-7437 Phone: 425 235-5569 Expiration Date: 12/30/2013 DESCRIPTION OF WORK: THIS PROJECT HAS SEVERAL COMPONENTS THAT INVOLVE UPGRADES OF EXISTING SYSTEMS AND DOES NOT REQUIRE ANY PHYSICAL CHANGES TO THE BUILDING FOOTPRINTS AND STRUCTURE, INCLUDING; SOUND INSULATION WORK, VENTILATION WORK AND UPGRADE AND MISCELLANEOUS WORK (WINDOWS, DOORS, INSULATION AND ABATEMENT). Value of Mechanical: $3,180.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature:; I hereby certify that I have read and governing this work will be complie Fees Collected: $186.50 International Mechanical Code Edition: 2009 Date: examied this permit and know the same to be true and correct. All provisions of law and ordinances with, hether specified herein or not. The granting of this permit does not pre construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. e to give authority to violate or cancel the provisions of any other state or local laws regulating Signature: Print Name: Date: 717 Z 6 �� This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. hAl z_nnz Printed nR-07-7013 PERMIT CONDITIONS Permit No. M13-043 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. ioc: IMC -4/10 M13-043 Printed: 08-07-2013 CITY OF TUKWILA Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.citukwila.wa.us Building Permit No. Mechanical Permit No. t't k Cr f 3 Plumbing/Gas Permit No. Public Works Permit No. Project No. (For office use only) Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 12055 44th Ave S • King Co Assessor's Tax No.: 3347400420 Suite Number: Floor: Tenant Name: Thanh Nguyen Property Owners Name: Thanh Nguyen Mailing Address: 12055 44th Ave S New Tenant: 0 Yes ® ..No Tukwila WA 98178 City State Zip r CONTACT PERSON = who do, we contact when your permit is. ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South Day Telephone: (206) 296-7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker@kingcounty.gov City State Fax Number: (206) 269-7315 Zip GENERAL CONTRACTOR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)) Company Name: not yet awarded Mailing Address: City Day Telephone: Fax Number: Expiration Date: Contact Person: E -Mail Address: Contractor Registration Number: State Zip ARCHITECT OF RECORD — All plans must be wet stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Jesse Holgate or Timothy Fenlason E -Mail Address: jesse@smstemper.com/tenlason@jonespayne.cge City State Day Telephone: (206) 624-2777 Fax Number: (206) 624-2973 Zip ENGINEER OF RECORD — All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H:\Applications\Fonns-Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: t-2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 MECHANICAL CONTRACTOR INFORMATION Company Name: Mailing Address: not yet awarded City Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: State Zip Valuation of Mechanical work (contractor's bid price): $ 3,180 Scope of Work (please provide detailed information): Use: Residential: New .... ❑ Replacement .... 0 Commercial: New .... 0 Replacement .... ❑ Fuel Type: Electric 0 Gas .... Other: Indicate type of mechanical work being installed and the quantity below: Unit Type: Qty Unit Type: Qty Unit Type: Qty Boiler/Compressor: Qty Furnace<100K BTU Air Handling Unit>10,000 CFM Fire Damper 0-3 HP/100,000 BTU Furnace>100K BTU Evaporator Cooler Diffuser 3-15 HP/500,000 BTU Floor Furnace Ventilation Fan Connected to Single Duct Thermostat 15-30 HP/1,000,000 BTU Suspended/Wall/Floor Mounted Heater Ventilation System Wood/Gas Stove 30-50 HP/1,750,000 BTU Appliance Vent Hood and Duct Emergency Generator 50+ HP/1,750,000 BTU Repair or Addition to Heat/Refrig/Cooling System Incinerator - Domestic Other Mechanical Equipment Air Handling Unit <10,000 CFM Incinerator — Comm/Ind H:\Applications\Forms-Applications On Line\2009 Applications 11 2009 - Permit Application.doc Revised: 1-2009 bh Page 4 of 6 PERMIT APPLICATION NOTES - • • Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER 1 R • !_ IZED AGENT: Signature: Print Name: >< h ' i4 ATE Mailing Address: H:Wpplications\Forms-Applications On Line\2012 Applications\Permit Application Revised - 2-7-12.docx Revised: February 2012 bh Date: /5 Day Telephone: (2t) eat— 2.7 % 7 City 8 b6 State Zip Page 4 of 4 City oTukwila, DepartmenCommunity Developm en t 6300 Southcerter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http •/%rvww ci tukwila wa us SET RECEIPT Copy Reprinted on 02-19-2013 at 09:09:21 02/19/2013 RECEIPT NO: R13-00837 Initials: WER Payment Date: 02/19/2013 User ID: 1655 Total Payment: 5,833.28 Payee: PAMELA K KUEHL (BY PHONE) SET ID: 020713 SET NAME: KING COUNTY SOUND ABATEMENT SET TRANSACTIONS: Set Member Amount D13-045 811.18 D13-046 842.70 D13-047 716.64 D13-048 748.15 D13-049 622.10 D13-050 1,067.51 M13-038 167.70 M13-039 167.70 M13-040 167.70 M13-041 167.70 M13-042 167.70 M13-043 186.50 TOTAL: -4-1-e7674' TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA 5,833.28 TOTAL: 5,833.28 ACCOUNT ITEM LIST: Description Account Code Current Pmts BUILDING - RES MECHANICAL - RES PLAN CHECK - RES STATE BUILDING SURCHARGE 000.322.100 000.322.102.00.0 000.345.830 640.237.114 TOTAL: 2,897.75 1,025.00 1,883.53 --21.0 0 5,833.28 INSPECTION NO. INSPECTION RECORD Retain a, copy -with permit M 13.013 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 cgs (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:_ Type of -Inspection: 1L) Alke-e-il Address: 1-0 _SS 44vrz._ Special Instructions: • Date Called: Date Wanted: ( -"� P.M. Requester: Phone Flo: s. _ to- . / —Z 2-2 ) Approved per applicable codes. El Corrections required prior to approval. COMMENTS: m L1p(a` p • Aclto0— .0 00-- .4. JS. 1 Inspctor: ,..,___,,,, A.; .., Date: 3 n REINSPECTION FEE R IRE . Prior °o,:.next inspection, fee must be paid at 6300 Southcenter Blvd:, Suite 100.. Cail to schedule reinspection. 07-01-2013 40 - City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director SHARYN PARKER 7277 PERIMETER RD S SEATTLE WA 981"08 RE: Permit Application No. M13-043 NGUYEN RESIDENCE 12055 44 AV S TUKW Dear Permit Applicant: In reviewing our current application files, it appears that your permit applied for on 02/07/2013, has not been issued by the City of Tukwila Permit Center. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or National Electrical Code every permit application not issued within 180 days from the date of application shall expire and become null and void. Your permit application will expire on 08/06/2013. If you still plan to pursue your project, a written request for extension of your application must be submitted to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit application. If it is determined that an extension is granted, your application will be extended for an addtional 90 days from the expiration date and you will be notified by mail. In the event that we do not receive your written request for extension or request was denied, your permit application will expire, become null and void and your project will require a new permit application, plans and specifications, and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M13-043 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 • PEJ1 C'O'SH) F* PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-043 PROJECT NAME: NGUYEN RESIDENCE SITE ADDRESS: 12055 44 AV S X Original Plan Submittal Response to Incomplete Letter # DATE: 02-07-13 Response to Correction Letter # Revision # After Permit Issued DEPART E CTS: 2-111—‘ ui ding ivision Public Works ❑ Fire Prevention Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 02-12-13 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route [71. Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03-12-13 Approved ❑ Approved with Conditions k Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Prirr Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LEt1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name S K M CONSTRUCTION INC UBI No. 601577401 Phone 4252355569 Status Active Address 14415 Se 143Rd Pt License No. SKMCOI*052L3 Suite/Apt. License Type Construction Contractor City Renton Effective Date 6/23/1995 State WA Expiration Date 12/30/2013 Zip 98059 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SKMCO**093L6 S K M CONSTRUCTION Construction Contractor General Unused 6/26/1991 6/17/1995 Archived SKMINI*976QL S K M INDUSTRIES INC Construction Contractor General Unused 11/13/2003 12/6/2009 Expired Business Owner Information Name Role Effective Date Expiration Date MORRISON, SHEILA K President 06/23/1995 Bond Amount MARKET SANDERS Agent 06/23/1995 06/25/2001 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 FIRST NATL INS CO OF AMERICA 6695979 06/17/2010 Until Cancelled $12,000.0004/26/2010 08/20/2012 4 DEVELOPERS SURETY a INDEM CO 188889C 12/30/2001 Until Cancelled 08/01/2010 $12,000.00 12/05/2001 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 16 JamesmRiver Ins 000495931 08/21/2012 08/21/2013 $1,000,000.00 08/20/2012 15 Co es River Ins 00049593 08/21/2011 08/21/2012 $1,000,000.00 08/18/2011 14 COLONY INS CO EPK300402 08/21/2010 08/21/2011 $1,000,000.00 08/20/2010 13 CENTURY SURETY CO CCP616634 08/21/2009 08/21/2010 $1,000,000.00 01/20/2010 12 AMERICAN STATES INS CO 01CH6810051 01/25/2009 01/25/2010 $1,000,000.00 01/23/2009 11 AMERICAN STATES INS CO 01CH6810051 12/30/2008 01/25/2009 $1,000,000.00 12/23/2008 10 AMERICAN STATES INS CO 01CH6810051 12/30/2007 12/30/2008 $1,000,000.00 12/07/2007 9 AMERICAN STATES INS CO 01CD87273820 12/30/2006 12/30/2007 $1,000,000.00 12/19/2006 https://fortress.wa.gov/lni/bbip/Print.aspx 08/07/2013 • ABBREVIATIONS EGEN D DRAWING NDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM C1RC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP F FD FLA FPM rr GA GAL GALV GPM GRD GWB HP HVAC HW HWC FIWG HAIR HWS IN KW LAT LING LWT M AX MBH M CA MIN M TG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TON TOD TPD TSP TYP V VD VTR WB W/ WG WAC ASBESTOS CONTAINING MATERIALS: AIR CONDITIONING: UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING,: REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED .CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT. BRITISH THERMAL UNITS .PER HOUR :CEILING DIFFUSER CUBIC FEET PER MINUTE 'CIRCULATING CONDENSATE :CONTINUATION/ COORDINATE coLD, WATER. DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING, AIR TEMPERATURE EXHAUST GRILLE EXTERNAL ;STATIC PRESSURE' ENTERING 'WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE: GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER, HOT WATER: CIRCULATION HIGH WALL GRILLE HOT WATER 'RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEmPERATvRE. LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS; MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR. OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT. OF CONNECTION. POUNDS PER SQUARE INCH RETURN AIR: REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY ;COOE, SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC, PRESSURE STA:Tic. PRESSURE DROP SPECIFICATIONS SEATTLE :RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP, OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH, WATER GAUGE WASHINGTON :ADMINIMAINE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL M.13.13„ DESCRIPTION DETAIL OR SECTION CALLOU; SHEET -WHERE SECTION ;OR DETAIL SHOWN XX OR a, 0 X. 7//1-117941 1•000000001101•004 limPPROPM, CD DIRECTION OF CUTTING PLANE SECTION ;CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE; ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING' HEAVY UNE. NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND, SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.1 DETAILS M2.0 MECHANICAL FLOOR PLANS GEN ERAL NQTES. • 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, , INCLUDING FLOOR PLANS,, :-DIAGRAMS, DETAILS, ETC-..„ AND ALL wQRK, As IDENTIFIED: IN THE spE09cA11oNs. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION* TESTING; TRAINING ,AND WARRANTY OF THE MECHANICAL SYSTEMS,: :AS SHOWN AND ESPECIFIED, PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION, 2. THE DESIGN Or MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE, EQUIPMENT SCHEDULE. , EQUIPMENT NAMED IN THE SpEcifteAlidNs' MAY BE SUBSTITUTED= PROVIDED THAT 'THE EQUIPMENT MEETS OR .EXCEEDS ,ALL SCHEDULED AND SPECIFIED ;CRITERIA, :AND HAS THE WRITTEN APPROVAL Or THE TECHNICAL REPRESENTATIVE. :COORDINATE THE rINS:TALLAMON .WI.TH ALL TRADES AND GUARANTEE IN WRITING THAT -NO ADDITIONAL. COST WILL. BE INCURRED DOE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD. VERIFY' ALL BUILDING AND SITE DIMENSIONS !BEFORE BEGINNING CONSTRUCTION OR .ORDERING EQUIPMENT. DO NOT SCALE FROM KANs, 4. DIMENSIONS,si-710wN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. :INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503,9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTMONS, CEILINGS AND :ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. 'DUCTWORK,: OR :STRUCTURAL COLUMN :PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT.: 6. 7. 8. 9. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT. WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 41-0* AFF. UNLESS NOTED OTFIERIMSE. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT UMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. MAINTAIN 3* -0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. SYMBOL ABBR DESCRIPTION $G -X DIFFUSER, REGISTER OR GRILLE. CALL OUT XXX CFM AMOUNT DN I . ON. 0 -0 C/41- 4:. UP DUCT OFFSET DOWN IN FLOW DIRECTION DUCT OFFSET UP IN FLOW DIRECTION DUCT W TROUT INSULA'TION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD 'VOLUME DAMPER; RA/EA RETURN AR OR EXHAUST „AIR DUCT RG SA RETURN AIR GRILLE SUPPLY AIR WILD; SIDEWALL SA SUPPLY AIR DUCT RA/EA RETURN AIR OR EXHAUST AIR DUCT SD EA SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER pELLINg, SUPPLY GRILLE cEILI NO RETURN GRILLE EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION - RECTANGULAR TO, ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH 01).OR(141) THERMOSTAT EQUIP LOCATION NG • 0 MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT SEPARATE PERMIT REQUIRED FOR: 0 Mechanical allectrical 171"Plumbing gtres Piping Cy of Tukwila FIP DIVISION MECHANICAL ELECTIRI CAL •COORDIN.ATI ON. ITEM NO. EQUIPMENT CONTROL EQUI PM ENT DESCRIPTION VOLTS PH: FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED - UNDER DIVISION BV -1, .2;. 3 BLENDING. UNIT' VENTILATOR SWITCHES- (ON, 'TIMER) 23 26 23 .20 N/A 23 26 N/A REMARKS 120 1 X X X 1,2 1 X X 1 REMARKS: 1 - VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 - DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK 'CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL WATTS VOLTS PHASE COMMENTS BV -1 115 WG 32"Lx12.25"Wx13.5"H 76 120 1 8V-2 1 40 .5" WG 32"Lx12.25"Wx8,5"H 76 120 1 1, Z 3 BV -3 140 .5" WG 32" Lx12.25"Wx8. 5"H 76 120 1 2 3 NOTE: 1.',COORDINATE THE CONSTANT AIRFLOW REGULATORS :(CAIVS),. WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALOES AMERICAN A. OR APPROVED EQUAL. G MLLE AND DIFFUS ER SCHEDULE MARK CFM STATIC PRESSURE IN LET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 50-1 115 toe WG 7" 7" WALL ALLGRILLE SG -2 140 <08" WG 8" 8" WALL ALLGRILLE 1, 2, 4 SG -3 140: <08" WG 8 WALL ALLGRILLE 1, 2, 4 OG -1 00-2 90 90 <08" WO 7" 7" 7" WALL WALL CAP 1, 2,3, 4 WALL WALL CAP .Z 4 OG -3 90 <08” WG 7" RG -1 25 <08" WG 44 WALL WALL CAP 1, 2, 3, 4 WALL DECO 1, 2, 4 REMARKS; 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 2 PAINT TO BE COORDINATED WITH TECHNICAL. REPRESENTATIVE: 3. PROVIDE WITH BACK/RAFT DAMPER AND INSECT SCREEN 4. BASIS OF DESIGN: AIDES A. OR APPROVED EQUAL. 5, BASIS OF DESIGN: SHOEMAKER A. OR APPROVED EQUAL, 6. PROVIDE WITH AN OPPOSED BLADE DAMPER WAC RESIDENCE CODE FLOOR AREA (SO. FT.) NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTI ATION PROVIDED NOTES 0810;03.2326 BV:1 742 90 CFM 90 CFM 1 0810.03.2326 BV -2 0810.03.2326 931 2 90CFM .qm. 1 275 2 90 CFM 90 CFM 1 1."VENTILATION PROVIDED PER THE WASHINGTON .:ADMINISTRATIVE CODE ,INAC):„ SECTION 51-51-15-08,1-TABLEs 'm1508,2 ..AN4 M1508.3 MINIMUM DUCT INSULATIONTHICKNESS. DUCT LOCATION MIN VALU E INOTES ON ROOF OR ON EXTERIOR OF BUILDIN G ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING WITHIN ,CONDITIONED SPACE OR IN HEATED BASEMENTS R-8 WITH WEATHERPROOF BARRIER 1.3 R-8 1,2,3 R-8 13 IN CEMENT SLAB OR IN GROUND R-5 1,3 NOTESt. 1.THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC' INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS,, 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH ..SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND -.- WHERE THIS SPACE IS NOT 'VENTILATED. OR OTHERWISE EXPOSED. TO :iCONDITIONED AIR. 3. REFER TO, 'WASHINGTON STATE ENERGY CODE FOR A00111044 pile.P11.P Permit PlAe, rrview approval is subject to errors and omission. 01' construction documents does not authorize :T;;:iori oi any adopted code or ordinance. Receipt Qto Copy and conditions is acknowledged: By • vu -t- tr---InDei-Th Data. PR/WING • N °TES; ASBESTOS CONTAINING MATERIALS ARE PRESENT AT THIS RESIDENCE.. THE CONTRACTOR !REMOVING ACM SHALL :REVIEW THE i:ExEc4TNE SUMMARY REPORT AND LAB ANALYSIS FOR EACH RESIDENCE: INDICATED :TO HAVE ACM PRESENT PRIOR TO.. START OF WORK AND WILL B.E.:RESPONSIBLE FOR ,:OVERSEEING ABATEMENT :PROCEDURES. THE CONTRACTOR SHALL I.DENTIFY. QUANTIFY, AND LOCATE ALL AREAS REQUIRING ABATEMENT, REFER.' TO SECTIONS 011101 AND 028200 FOR REGULATED MATERIALS ABATEMENT, 2. LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. REVISIONS No changes shall bo made to the scope of rt,rls viqthout prior approval of Tukwila Building Division. VT177:- rvsision3 will require a new plansubmittal Lnd may include additional plan review fees. TH MOSTAVSW .TCH• HOURS., 'OF :OPERATION SET BV -1 SWITCH TO OPERATE '1 OF EVERY 3 HOURS, SET BV -2 :,SWITCH TO OPERATE 1 OF EVERY 2 HOURS,: SET BV -3 :SWTCH TO OPERATE 1 OF EVERY 2 HOURS. RECEIVED CITY OF TUKWILA FEB k') 7 2013 PERMIT CENTER MECHAN ICAL VENTILATION :CALCULATION BV -1 P ER SRC M1508.3 CIF = OR / (WM X F) OR = (FROM TABLE itEGR = VENTILATION F = FRACTION OF QF = XX / (1 X 1/3) 1508:-,2). EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES,: 1 OF EVERY 3 HOURS) = 1 OPERATION :141 = 90 CFM MECH AN CAL -VENTILATION 'CALCULATION B V 2, 3 PER SRC M1508.3 QF = QR / (&EGR X F) OR = (FROM TABLE 1508.2) 41 SEGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 F = FRACTION OF OPERATION 112. QF = XX / (1 X 1/2) = 90 CFM OF EVERY 3 HOURS) = 1 REVIEWED FOR 'CODE COMPLIANCE APPROVED FEB 14 'nil City of Tukwila BUILDING DIVISION 13•-• 0 3 S.M. :S.T.E.1MPER ARCHITECTS A Professional Limited uonity Company 4000 DEMIDGE WAY SW SUITE 290 SEAM& WA (03106 (204) 824-41177 ° PAX (2o) I4S4-2978 TH GR.ZiENI3USC1I GROUP, ThIC 0. 40444 0) ) ) 'OM :374.0.000 111.4"711)31/Cidi PREErVIDDI (11114411144n4200). 37641Fg. TIONAL AIRPORT KING -COUNTY .1t4TE.RN MPROVEMENTS 0 0 cr AIP NUMBER 3-53-0058-45 DATE TUKWILA WASHINGTON 09/1:012012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT EXPIRES; 9/08/2014 Mt 0 081003.2326 SEE, CLOSET CHASE, REFER TO ARCHITECTURAL, INSTALL BLENDING UNIT VERTICALLY IN CHASE 7"0 FAMILY ROOM STORAGE LANDING FUR •GAS METER BASEMENT MECHANICAL PLAN • • SCALE: 114' BASEMENT. BV -1 BV -2: BV -3 KEY TO VENTILATION ZOKIS SCALE: NONE NilliDORTH UPPER NORTH LOWERED SOFFIT, REFER TO ARCHITECTURAL., SEE SOFFIT, REFER TO ARCHITECTURAL LIVING ROOM: MAIN FLOOR: SCALE 1/4" = 1 -0" MECHAN ICAL PLAN DRAWING NOTESt.... 1.. FIELD VERIFY OUTSIDE .AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3, FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SRC M1500,04. 2, FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT DF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S). WITH NEW FILTERS. SEE SEE BEDROOM M 4 TYP ALL RG -1 WALL 2.1 GRILLES 25 RG -1 , 25 BEDROOM 3 SG -1 140 4110 7"0 44. TYP 5 •EIV -3, SEE UPPER FLOOR MECHANICAL PLAN SCALEr, 1/4" FLAG NOTES: SV -1 AND DUCTWORK ROUTED IN CHASE. BV -2 AND DUCTWORK ROUTED IN SOFFIT. BV -3 AND DUCTWORK ROUTED IN ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCHES WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN: TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION' 260010. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE: QPFRATIM INSTRIKTIPKW PER :SRC Mi 508.6.4.COORDINATE FINAL SWITCH LOCATION WITH HOMEOWKR, TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATI ONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. 3 TYP Ykk-"S-- 043 REVIEWED FOR .ODE COMPLIANCE APPROVED FEB 14 ,nv • City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 0 7 2013 PERMIT CENTER EXPIRES: 9/08/2014 SM. STEMPER ARCHITECTS A 'Professional Limited Welts Csansany 4000 .DEIRIDGE WAY SW SUITE 200 SEATTLE, WA 00100 (2O) 004.-0117 X (2o) 624-11076 TILE GREENBT.LSCIL GkOUP, INC 0111004114.40111, ))) ./Almatiedilfi. VIDEO Is 111KIWICAL. ENCINEERIC $11EET SUR 201 SPITIA 110110 .470 3711-01569 (WS) M-0641 PAX 0810).032326 EDY IMPROVEMENTS ILA WASHINGTON AIP NUMeER 3-53-0058-45 DATE 09/10/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT MECHANICAL PLANS M2.0 0810.03.2326 SUPPLY AIR DUCT MOTOR ACCESS FILTERS ACCESS OUTSIDE AIR DUCT RETURN AIR DUCT. INSTALL GRILLE LOW INSTALL UNIT VERTICALLY IN CLOSET HOLD TIGHT TO STRUCTURE NOTES: 1, INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. VERIFY UNIT ORIENTATION BEFORE EINSTALLA110N. 3. INSULATE ALL DUCT AS SCHEDULED. BV -1 'INSTALLATION DETA!".. SCALE NONE SHEETMETAL TRANSITION TO WALL CAP NECK SIZE DUCT PER: PLAN CAULK 2X BLOCKING 2X BLOCKING FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER MANUFACTURERS WRITTEN INSTIRLIC11ONS.. 2. SEE PLANS, FOR VOLUME DAMPER LOCATIONS, 3. COORDINATE ,WITH ARCHITECTURAL DETAIL DRAWINGS; WALL CAP DETAI.... SCALE: NONE HOLD TIGHT TO STRUCTURE OUTSIDE AIR DUCT RETURN AIR DUCT FILTER ACCESS BV -2, (E)CEILI COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE NG SUPPLY AIR DUCT SOFFIT • MOTOR ACCESS: NOTES: 1, INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. Z VERIFY UNIT ORIENTATION BEFORE ItsISTALLATION. BV -2 1 NSTALLATION DETAIL SCALE: NONE CAULK SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN 2X BLOCKING 2X BLOCKING FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTION& 2. SEE .PLANS :FOR VOLUME DAMPER LOCATIONS. 3. WALL $UPPLY INSTALLATION SHOWN, RETURN SIMILAR. WALL. SCALE: NONE RILLE DETAIL MOTOR ACCESS FILTER ACCESS: RETURN AIR DUCT OUTSIDE AIR DUCT ATTIC: HOLD TIGHT TO STRUCTURE BV 3 SUPPLY AIR DUCT NOTES: 1. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 2. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 3. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE BV -3 INSTALLATION DETAIL SCALE: NONE Mlft- 0 IA3 REVIEWED FOR , CODE COMPLIANCE APPROVED FEB 14 will City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 0 7 2013 PERMIT CENTER S.M. STEMPER ARCHITECTS A Pm/Anima/ UMW 11011.1t7 Company 4000 DEIBIDGE WAY SW SUITE 200 SUM% WA 08100 way 624.-27/7 PAX 000 24-29133 TI -14 OR.EENBUSCH GkOtiP, INC atatiosaato• s. . Adja40, MEranDeNEEHING ant-ottisa 0810.03.2314 KING COUNTY. INTERNATIONAL AIRPORT LL RESIDENTIAL AIRC AIP NUMBER 3-53-0058-45 SEATTLE WASHINGTON DATE 09/19/2012 lSSUED1000/0 Op PROJECT ENGINEER DO PROJECT MANAGER DRAVVN DO JA, DT EXPIRES: 9/08/2014 0810.03.2326