Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-050 - ONE SOURCE TALENT - ALTERATION
ONE SOURCE TALENT 12720 GATEWAY DR suri1E 200 M13-050 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 2716000070 Address: 12720 GATEWAY DR TUKW Project Name: ONE SOURCE TALENT Permit Number: M13=050 Issue Date: 03/11/2013 Permit Expires On: 09/07/2013 Owner: Name: EPROPERTY TAX INC DEPT #207 Address: PO BOX 4900 , SCOTTSDALE AZ 85261 Contact Person: Name: STEVE FLINK Address: 7717 DETROIT AV SW , SEATTLE WA 98106 Email: STEVE.FLINK@MACMILLER.COM Contractor: Name: MACDONALD/MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA 98106 Contractor License No: MACDOFS980RU Phone: 253 680-3172 Phone: 206-768-4180 Expiration Date: 01/03/2015 DESCRIPTION OF WORK: INSTALL (2) NEW DIFFUSERS AND MISCELLANEOUS DUCTWORK PER PLANS Value of Mechanical: $800.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied ami .th, Fees Collected: $176.56 International Mechanical Code Edition: 2009 Date: 8Att irp d this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: 5/0 Date: (i3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. nn 4 4 01114.) • PERMIT CONDITIONS Permit No. M13-050 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 1 doc: IMC -4/10 M13-050 Printed: 03-11-2013 CITY OF TUKWILA ' Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://vo,vw.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: :Date1Application Expires ";'' MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** 'SITE LOCATION King Co Assessor's Tax No.: 2716000070 Site Address: 12720 Gateway Dr. S Tukwila, WA 98168 Suite Number: 200 Floor: 2 Tenant Name: GATEWAY BLDG #7 - ONE SOURCE TALENT New Tenant: 0 Yes m.. No PROPERTY OWNER ' Name: STEVE FLINK Name: RREEF AMERICA LLC City: SEATTLE State: WA Zip: 98106 Address: 20415 72ND AVE S STE# 210 Email: steve.flink@macmiller.com City: KENT State: WA Zip: 98032 CONTACT PERSON N - person receiving all project communication Name: STEVE FLINK Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (253) 680-3172 Fax: Email: steve.flink@macmiller.com 'MECHANICAL CONTRACTOR INFORMATION ' Company Name: MACDONALD MILLER Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-4278 Fax: (206) 768-4279 Contr Reg No.: macdofs980ru Exp Date: 12/31/2013 ' Tukwila Business License No.: BUS -0100868 Valuation of project (contractor's bid price): $ 800 Describe the scope of work in detail: INSTALL (2) NEW DIFFUSERS AND MISC DUCTWORK PER PLANS Use: Residential: New ❑ Replacement 0 Commercial: New 0 Replacement Fuel Type: Electric m Gas 0 Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 2 Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type QtY Air handling unit >10,000 cfm 2 Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 2 Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT,APPIICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN Signature: Print Name: DARLA DOLL Day Telephone: (206) 768-4278 Mailing Address: 7717 DETROIT AVE SW SEATTLE WA 98106 City State Zip OR AUTHORIZED Date: 02/26/2013 H:\Applications\Forms-Applications On Line'2011 Appltcattons\Mechamcal Permit Application Revised 8-9.11 .docx Revised: August 2011 bh Page 2 of 2 • City of Tukwila 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2716000070 Address: 12720 GATEWAY DR TUKW Suite No: Applicant: GATEWAY BLDG #7 RECEIPT Permit Number: M13-050 Status: PENDING Applied Date: 02/26/2013 Issue Date: Receipt No.: R13-00902 Payment Amount: $176.56 Initials: BLS Payment Date: 02/26/2013 11:58 AM User ID: ADMIN Balance: $0.00 Payee: MACDONALD MILLER TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3559 176.56 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 141.25 000.345.830 35.31 Total: $176.56 Printcrl• 09-9R-9013 .-- INSPECTION NO. INSPECTION RECORD Retain a copy with permit -3- 656 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 12.4 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: C:11•1 t stnae i n LEA--; Type of Inspection: :::_a k i e L. Address: I D.12.0 G►eiet,JAL4 Z Date Called: Special Instructions: Date Wanted` . V--- 3 ,-- 1 — tom (,am: p.m. Requester: Phone No: ao6-c Lit - 2.370 °j Approved per applicable codes. Corrections required prior to approval. COMMENTS: Inspector: r Date: REINSPECiION FEE REQUIRD. Prior to ne�ft inspection; fee must be paid at 63 0 Southcenter Blvd.. Suite 100. Call to schedule reinspection:.. a7.)MacDonald -Miller FACILITY SOLUTIONS C(N\ NE,BB CERTIFIED TEST,yAD:JUST & BALANCE REPORT GATEWAY TONE SOURCE TI WT'238 THE DATA PRESENTED IN THIS REPORT IS A RECORD OF SYSTEM MEASUREMENTS AND FINAL ADJUSTMENTSTHAT HAVE BEEN OBTAINED IN ACCORDANCE WITH THE CURRENT EDITION OF THE NEBB PROCEDURAL STANDARDS FOR TESTING, ADJUSTING, AND BALANCING OF ENVIRONMENTAL SYSTEMS. ANY VARIANCES FROM DESIGN QUANTITIES, WHICH EXCEED NEBB TOLERANCES, ARE NOTED IN THE TEST -ADJUST- BALANCE REPORT PROJECT SUMMARY. SUBMITTED & CERTIFIED BY: MR BRIAN WHEELER, NEBB SUPERVISOR REPORT DATE: 03-12-13 Certification Expiration Date: March 31, 2014 FIELD FOREMAN: RON LANDBERG-SR SYSTEMS ENGINEER FIELD TECHNICIAN: BRADLEY SHARP-NEBB CERTIFIED TECHNICIAN/CXA MACDONALD-MILLER FACILITY SOLUTIONS MECHANICAL SERVICES #2661 7717 DETROIT AVENUE SW SEATTLE, WASHINGTON 98106 PHONE: (206) 763-9400 FAX: (206) 767-6773 4Z15) MacDonald -Miller FACILITY SOLUTIONS TAB REPORT;SUMMARY:• GATEWAY 7 ONE SOURCE TI JOB # 733-6169 1) General Notes a) HVAC balancing was completed 3-12-13. b) TAB work was in accordance with NEBB procedural standards. c) Outlet volumetric flow rates were measured by use of a calibrated Flow Hood. d) Design information was obtained from mechanical drawings, submittals, specifications, or shop drawings as available. 2) Scope of work a) Test of Balance of the new air distribution systems with in the TI area. b) Documentation of any deficiencies and to provide a certified balance report. 3) Description of the System a) 1 Variable Volume Terminal #238 attached to existing building air distribution system b) Wall mounted thermostat that is integrated with the energy management system. 4) TAB Procedures Summarized a) Outlet balance was done with a Flow Hood. b) DDC was calibrated using the Echalon — Lonworks program in comparison to measured actual airflows 5) Other miscellaneous notes a) None Field Technician: Bradley Sharp (Test and Balance) Pg. 1 Ca)MacDonald -Miller FACILITY SOLUTIONS AC BDD BHP B.S. CEG CRG CFM, CHWR CHWS CSD CWR CWS DD DP DIFF DMPR DNA DNL DNT DWDI EAT (DB) EAT (WB) EC EF EG ESP EWT FPM FH GPM HF AIR CONDITIONING UNIT BACK DRAFT DAMPER BRAKE HORSEPOWER BIRD SCREEN CEILING EXHAUST GRILLE CEILING RETURN GRILLE CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING SUPPLY DIFFUSER CONDENSER WATER RETURN CONDENSER WATER SUPPLY DIRECT DRIVE DIFFERENTIAL PRESSURE DIFFUSER DAMPER DATA NOT AVAILABLE DATA NOT LISTED DATA NOT TAKEN DOUBLE WIDTH DOUBLE INLET ENTERING AIR TEMP. (DRY BULB) ENTERING AIR TEMP. (WET BULB) EGG -CRATE RETURN EXHAUST FAN EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE FEET PER MINUTE FUME HOOD GALLONS PER MINUTE HEPA FILTER HP HP HWR HWS INAC LAT (DB) LAT (WB) LD LWT MAX MIN 0 OBD OD OSA RA REQ'D RH RTU SA SP SWG SWR SWSI T TSP T.P. T -STAT TYP 0 V.D. HORSEPOWER HEAT PUMP AIR CONDITIONING UNIT HEATING WATER RETURN HEATING WATER SUPPLY INACCESSIBLE LEAVING AIR TEMP. (DRY BULB) LEAVING AIR TEMP. (WET BULB) LINEAR DIFFUSER LEAVING WATER TEMPERATURE MAXIMUM MINIMUM WIDE OPEN DAMPER / AIR PATH OPPOSED BLADE DAMPER OUTSIDE DIAMETER OUTSIDE AIR RETURN AIR REQUIRED RELATIVE HUMIDITY ROOFTOP UNIT SUPPLY AIR STATIC PRESSURE SIDE WALL GRILLE SIDE WALL REGISTER SINGLE WIDTH SINGLE INLET OUTLET NEAREST THERMOSTAT TOTAL STATIC PRESSURE THERMALLY PROTECTED THERMOSTAT OR SENSOR TYPICAL VOLTAGE PHASE / DUCT DIAMETER VOLUME DAMPER Pg. 1 CZ)MacDonald -Miller FACILITY SOLUTIONS Project Job Number Gateway 7 One Source TI 733-6169 Area Served WT 238 System Air Outlet Test Report Existing Outlet Design Preliminary Final Percent of Design No. 1 Type 1 Size 1 Ak Vel. 1 Flow Vel. 1 Flow Vel. 1 Flow_ Totals Remarks: Box Information - VVT 238 Ak= 0.731 / 92% open 680 669. 669 98% Test Date: 3/12/2013 Readings By: BWS Test Date Readings By Page: 1 CD 8 1 170 169 169 99% 2 CD 8 1 170 219 165 97% 3 CD 8 1 170 145 170 100% 4 CD 8 1 170 136 165 97% Totals Remarks: Box Information - VVT 238 Ak= 0.731 / 92% open 680 669. 669 98% Test Date: 3/12/2013 Readings By: BWS Test Date Readings By Page: 1; (.3) 1 2x24 ‘\j ----------11 11 1 4 SI, A „•1 200 (M)82x18° I N771 7 C"1 88 37020Tr- k, _ [ I \N 1 2x24 L-' 80 It: (Th. 8x8 03(7 • ri.N.8x8 ! 8o 1 -r\P-CZN- ---"i II CAP ,K1 '1,1 L q%132:f22:;-. / 24o • :t __.,.....__— , .,.......1 - ' _,..../3,4,..„ Relocate tstat v 1 4 r, , I! ,?4,24 -56n ,00 r''? 4) C R.! I I `) -7- \ OAPI s' axs ed3 7 Li 180 219 v I cAP: 0 RA1 r- '716.0 • , . ., 2 . W' R 38x 7 3 RA •• 1 f- ,/; DU REFER PIPINGAND zi.ELECTRIC4=CONDUIT DN TO 1ST FLOOR. ®-{ASE BY C.C. 1! t,0 ODEMO FLOOR PLAN • EA TRAVEL MM. a£Jtbi n TEAM 5EPARATgi BALL OPROPOSED FLOOR PLAN KALE inp, 3762 S • ODD • 33 OOp.05. ENGAE EMT. NOT 04W TO EXITING PROM PFEl10E TENANT (WEST -.APART LCAD OMR 5/0 .TRAVEL MT* TO PONT NE 1 VIM MAP T.@C FOR I OM E A4OMD ENERGY CODE NOTES iRAT KA WAN, ELKARC ALINED IP RAVE vA•GOt at ALL SAL 10 1,11 MEI NA MR.,. MAL LEAL ISEOARSN. MVO A6.a6TO GENERAL NOTES pEMO: l F1AIME E325TNG CALLS M SNWUL AND PATG4 AND R PMR FLOOR CALLS AND GEl1D 2. PATG4 40 REAR ALL DAMAGED EMUS 3. FEMME E+25334G DOLR lC JAMS AS UMAN MESE F P0930.E1 FUCK ElEG1FCGY N DOWD FALLS. CAP N J -B0% MOVE GRID OR AT ROOF. LADLE ASCU 314 OR= AID PANEL 5. CAP ALL FLIDONG NOT BE3C TEED. CAP 31437E FALLS MARC OV A}BiLT FCR LOCADOU 6. REPINE ALL BOOR RASES AID NAE FROG. NT • 1. 14 FE311132014, FEMME ROORNS BASE 4143 MEET P4F2I106. YA66C0(, WADER 410 5NF 53 1ER #0 WAD. 1449'45. 6 MLOF44VAGAD SPFEIQER M RESUMED 3 RELOCATE %MTOWP M REWIRED LEGEND PO..1 m PiORE CP V$3$03ala,Ta - OSTDo 0111 to el. Itirlohl0 11, • 0 0 p.T,a oat itameLl0( PRET • CLOLV ▪ ,a„1AEaAM 4017.AMa6AMOM ELLL OMR RITLT MAR MA ERTL, Mt O J.. POP KM AO. Nag 11 Ba NW R..ARATla,11a m .a.em°aaMACAW 3.'a RENEKBE s,mu ® to0,mam.a4T1Yla fumncan(Aa cow 4. unio m > ,1 Tans RILSOWin DIr QA917.To MOWEDWORD 5 • � ROOIh Du=l14 (C414T.54 (CARPET, 145 VC/ IT • 6.1•..®6.6 E .6i 61P150. MAM. Alla.EBOED.Cu Tr.1. (414, •LOONI NM .1 SM5.0de' Eff 6N.,6,P66.TAMED, CEARA ROAMED AO2BECAL !AIM WALL TYPES >.wm 6A Rn. WV • 7P ac . Aa.nuL al.,A 671, eo. 0011.1$015 POOR SCHEDULE MIER 411“;113.. o RAID 0..CBWNIM va•TOC® 0000.1 .JAM MIA61IPM i 1-3 DEN) Ic Tumoa La 1TAc®1l PM 663 wow..6LL=P.mnFBA 1 8 GATEWAY CORPORATE CENTER: BLDG 7 T-1 GCmsa••YSm'MI*CAM., 10•1$170.10.. Sens row 1mma61x14Tas6T-1. 1E04117T'S43TM (=>MacDonald -Miller FACILITY SOLUTIONS MacDonald Miller Facility Solutions Calibration Certification 2013 Calibration Tool# Model# Serial# By Instrument Calibration Date Calibration Due Rotating Measurement 1003510 461995 Q342831 Davis Inotek 7/19/2012 7/19/2013 Temperature Measurement Air 1003519 ADM -860C M07266 Shortridge 5/14/2012 5/14/2013 Temperature Measurement H2O 80PK-5A Mac 63690 1555257 Davis Inotek 7/20/2012 7/12/2013 Electrical Measurement 1003918 Fluke 902 94710185 Davis Inotek 7/19/2012 7/19/2013 Temperature Measurement Air 1003519 ADM -860C M07266 Shortridge 5/14/2012 5/14/2013 Air Velocity Measurement 1005875 TSI 9555-P 9555P0841032 TSI 8/29/2012 8/29/2013 Temperature Measurement Air 1001726 ADM -860C M05779 Shortridge 5/11/2012 5/11/2013 Humidity Measurement 1005875 TSI 9555-P 9555P0841032 TSI 8/29/2012 8/29/2013 Hydronic Pressure Measurement 1003731 HM670 70725068 Alnore 10/12/2012 10/12/2013 Hydronic Differential Pressure Measurement 1003731 HM670 70725068 Alnore 10/12/2012 10/12/2013 10/22/2012 S:\FieldEng\NEBB_TAB(D)\Tools\Calibration Certification NATIONAL ENVIRONMENTAL BALANCING BUREAU �.geditticiarteettipct e girt/alp ffrailley S with - M ac?J'ona .9ti�rfacility Solutions has certified as a NEBB Testing, Adjusting and Balancing (TAB) Technician for Air and Hydronic Environmental Systems .March. 31, 2014 Expiration Date NEBB President January 5, 2012 Date Chapter President " Date 201L aft, Certified PP oTess oval's Stamp eiAncli;iD1wf Certification TESTING, ADJUSTING AND BALANCING BUREAU 'THS PROFESSIONAL'S CHOICE" - Sheet JYtetal and Air Conditioning Industry This certifies that Bradley Sharp blas successfufy compted tfie requirements for IAB& Commissioning Supervisor December 30, 2011 CX977756S Certification x December 30, 2011 Valid Date December 31, 2013 Expiration Date valid during qualified employment Labor Co-Chaitnian Management Co -Chairman Administrator of TABB 410ERMiT COORD COP* PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-050 DATE: 02/26/13 PROJECT NAME: ONE SOURCE TALENT SITE ADDRESS: 12720 GATEWAY DR, STE 200 X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: pi(iOM, 't3 Building Division Public Works yr rty Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ Comments: DUE DATE: 02/28/13 Not Applicable ❑ Permit Center_ Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route 14 REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 03/28/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only. CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople linter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L8:1 to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MACDONALD/MILLER FAC SOL INC UBI No. 602254260 Phone 2067684180 Status Active Address Po Box 47983 License No. MACDOFS980RU Suite/Apt. License Type Construction Contractor City Seattle Effective Date 12/31/2002 State WA Expiration Date 1/3/2015 Zip 98106 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVC0r988RC DIVCO INCORPORATION Construction Contractor General Unused 12/3/2002 11/7/2014 Active LINFOAR980QG LINFORD AIR 13 REFRIGERTN INC Construction Contractor General Unused 11/7/2002 11/7/2004 Archived ENCOMMS984CA ENCOMPASS MECHANICAL SERVICES Construction Contractor General Unused 2/1/2002 2/1/2004 Archived MACDOMR026RU MACDONALD MILLER RSDNTL INC Construction Contractor General Unused 12/31/1998 12/31/2001 Archived DIVCOI'031L4 DIVCO INC Construction Contractor General Unused 6/24/1997 8/1/2003 Archived MACDOMR0760PMACDONALDMILLER RESIDENTIAL Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDOM*248J9 MACDONALD MILLER CO Construction Contractor General Unused 4/29/1976 2/1/2002 Archived Business Owner Information Name Role Effective Date Expiration Date GOUGH, DAVID ANTHONY Director 12/29/2010 HOEL, STEPHANIE W Member 05/14/2010 SIMONDS, DERRICK R President 05/14/2010 WEBSTER, MARK E Vice President 05/14/2010 TURLEY, DOUGLAS Chief Executive Officer 02/13/2008 01/04/2011 TURLEY, DOUGLAS Chief Operating Officer 02/13/2008 01/04/2011 SIGMUND, FREDRIC President 12/31/2002 01/04/2011 HACK, RICHARD Secretary 02/13/2008 01/04/2011 KOPET, TYLER Treasurer 12/31/2002 01/04/2011 LOVELY, STEVE C Vice President 12/31/2002 01/04/2011 Bond Information Bond Company Name LIBERTY MUTUAL INS CO Bond 1 Page 1 of 2 Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 023006951 12/11/2002 Until Cancelled $12,000.00 12/31/2002 Assignment of Savings Information No records found for the previous 6 year period httos://fortress.wa.2ov/lni/bbin/Print.asnx 03/11/2013 SIT -: PLAN \ITY MAP SEPARATE PERMIT REQUIRED FOR: Mechanical Electrical Plumbing Gas Piping ity of Tukwila BI.6I ,Dia;si ON REVIEWED FOR CODE COMPLIANCE APPROVED MAR 0 6 2013 City oft ila BUILDING !SION SIT{; & BLILDING STATISTICS — BUILDING CODE: IBC 2009 — BUILDING TYPE OF CONSTRUCTION: III—N SPRINKLERED — OCCUPANCY GROUP: B — BUILDING AREA FIRST FLOOR= 33,039 S.F. SECOND FLOOR= 33,467 S.F. TOTAL= 66,506 S.F. — OCCUPANCY LOAD FIRST FLOOR OFFICE= 9,709 S.F. / 100= 97 CONFERENCE & LOUNGE= 1.229 S.F. / 15= 82 CLASSROOM= 6,086 S.F. / 20= 304 LIBRARY= 1,156 S.F. / 50= 23 TOTAL= 506 SECOND FLOOR OFFICE= 8,783 S.F. / 100= 88 CLASSROOM= 10,902 S.F. / 20= 545 TOTAL= 633 LH:GAL I) H S C RIPTIO N PARCEL B OF TUKWILA SHORT PLAT 89-1—SS, RECORDED UNDER AUDITOR'S FILE #8904120877. TAX ID. NUMB �'R 271600-00-0070-06 Scop OF WORK REM VE EX ST NG N BEAR NG WALLS, A J5,1P BEAR NG WALLS. BU L NG ENVEL PE N c_a-) o,f,Fuse's —Art 15 IvcT a21c C VSTRUCT NEW CHA ti GE TENANT WORK AREA REVISIONS No chsniles shall hn rn ;dr? to Wit+ Ammo, of work without prior opprowl f Tukwila Building Division, NOT:: Cevisions will require n new Wen submitI*1 and may include additional plan reg/Iew fees, 3,262 SF Permit No. —09 Pian review approval is subject to errors and omissions. Approval of construction documents does not authorize tic: violation of any adopted code or ordinance. Recopt of approved Field Co ' y and mations is acknowledged: By Date: '3 hi City Of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA FEB 2 6 2313 PERMIT CENTER 0 L• - co a 3 0 01-29-13 0 DESCRIPTION h• CO O o 1 1 o8 Z a 11Lei MVV09 T-0 C:\Documents and Settings\AII Users\Documents\CAD\1987-1989\8704-7\One Source Talent 200 01-29-13\T-0-T-2.dwg, T-0, 1/30/2013 10:32:22 AM rJ 11 REMOVE EX. NON BEARING UJALL5 AND DO I I LJH DEMO _oo AN 6CALE 1/8"; I' ay5`^TL 141-10" 201-111 I4'-S" 1S'-2" 15'-2" 16OFFICE OFFICE 4'-4H ICO OFFICE 86' TRAVEL ID STANCE 5514 3e OFFICE 9 �.5 I+�t-x]11 34`- T-6" ENERGY CODE NOTES NEW 6TORAGE 31' NEW OPEN OFFICE LUNCH L.] CONF 121 F0POS=-ID 1 1 OCR PLAN SCALE 1/S"w1' 3,262 SF WOO :I 33 OCUPANTS, SINGLE EXIT, .NOT CHANGE TO EXITING FROM PREVIOUS TENANT (RR EF) -OCCUPANT LOAD UNDER 50 -TRAVEL DISTANCE TO POINT OF 2 EX1T6 86LF THERE FOR 1 EXIT IS ALLOWED I) NEAT IS VIA GAS, NO ELECT RIG FEAT ALLOD 2) PROv1DE VAPOR: ON ALL WALL TO THE SWARM SIDE 3) CAULK AND SEAL ALL OPENINGS TO OUTSIDE OR UNHEATED SPACES INCLUDING, I1 AT€•IER-STRIPPING AT ALL EXTERIOR DOORS. 4)MAXIMUM ALLOWABLE LOAD FOR SWITCH IS SO% OF 20 AMP CIRCUIT. 5) PROVIDE DUAL LEVEL SWITCHING IN ALL ROOMS ADJACENT TO EXTERIOR €UINpOU11S T' 1- X Y Y EXITI T-10" EXISTING TEANT SEPARATION WALL SCP. AREA GENERAL NOTES DEMO: L REMOVE EXISTING WALLS AS SHOWN, AND PATCH AND REPAIR FLOOR, WALLS AND CEILING 2. PATCH AND REPAIR ALL DAMAGED WALLS . REMOVE EXISTING DOORS AND JAMBS AS SHOWN (REUSE IF POSSIBLE) 4. REMOVE ELECTRICAL IN DEMOD WALLS, CAP IN J -BOX ABOVE GRID OR AT ROOF, LABLE 3-50X WITH CIRCUIT AND PANEL CAP ALL PLUMBING NOT BEING USED, CAP INSIDE WALLS (MARK ON AS -BUILT FOR LOCATION) 6. REMOVE ALL FLOOR FINISHES AND BASE THROUGH OUT 1, IN RFSTROOMS, REMOVE FLOORING, BASE, AND TOILET PARTITIONS„ WAINSCOT, COUNTER AND SINK, SNOWED AND WALL FINISHES, S. MODIFY R-IYAC AND SPRFNKL.ER AS REQUIRED 9, RELOCATE SWITCHING AS REQUIRED LEGEND A EXISTING WALL NEW STEEL STUD WALL TO UNDERSIDE OF CEILING W/ SOUND INSULATION EXISTING WALL TO BE REMOVED. NEW DOOR EXISTING DOOR FOUR -FLEX OUTLET DUPLEX OUTLET MALL TELEPHONE OUTLET AND DATA, MUDRING, CONDUIT AND FULL STRING ONLY. SUPPLY AIR RETURN AIR SUPPLY AIR REVIEWED FOR CODE COMPLIANCE APPROVED 14AR 06 2013 City of Tukwila BUILDING DIVISION Q v v EXIT I E N J -BOX FOR POWER ANDJOR PHONE ILLUMINATED EXIT SIGN ill/ PATHWAY LIGHTING TX 4' EXISTING OR RELOCATED 3 -TUBE FLUORESCENT (88 WATTS) 2' X 4' NEW OR RELOCATED 2 -TUBE FLUORESCENT (66 WATTS) 2' X 4' EXIST1NG 2 -TUBE FLUORESCENT TO REMAIN (66 WATTS) 2' X 4' EXISTING 2 -TUBE FLUORESCENT TO BE REMOVED MP STORED OR REUSED EXISTING NEW DEDICATED SWITCI-4 ROOM MOVE EXISTING FINISHES .._ i"' ... "° 1.1 O 1OUT (CARPET, SASE, vCT,) I-5 FLOOR: NEW CARPET 10 BASE: NEW 6" BASE WALL: GYP. BD. (PAINTED) CEILING: SUSPENDED ACOUSTICAL (+9`AFF) S FLOOR. NEW VCT BASE: NEW 6" BASE WALL: GYP. BP. (PAINTED) CEILING: SUSPENDED ACOUSTICAL (+''AFF) WALL TYPES 3.1/2"x25 GA. S T L STUD e 24" O.C. TO ACOUSTICAL CEILING, CIYP. BD. BOTH SIDES DOOR, SCHEDULE (LEvER HANDLES) EI Ex. 3' X 5' S.C. WOOD DOOR WOOD JAMB (STAINED) 2 PAIR BUTTS; LOCKSET, WALL STOP, CLOSER MI5 20 MN. RATED) E2 -E5 EX. 3' X 5` S.G. WOOD DOOR WOOD JAMB (STAINED), 2 PAIR BUTTS, LOCKeeET, WALL STOP 1-3 NEW 3' X 8' SG. WOOD DOOR, WOOD JAMB (5TA1NED), 2 FAIR BUTTS, LATCHSET, WALL STOP, SILENCERS 8 x8 . _.....,\ is 4 SI. X 6x8 4. A L it -M, 8 x.8 A 00 • i i'ti f �ZJ YJ 1 80 k 70 ✓• L.4 :,; ; 8 0 t'r 1 • J' J r Relocate tstat (- YP 4) 8x8/I7OCFM (2 Typ) • LE As. 3 CAp 80 RP I . ' - ; PA °,.... Vii) REFER PIPING ANb ELECTRICAL ..:-..CONDUIT DN TO "1 'T FLOOR. CDTHASE [Tr,: C.C. M� p so RECEIVED CITY OF TUKWILA FEB 2 6 2013 PERMIT CENTER Z 3 Cen W Eco E Lc_ 2). fa co co 1 CSI W s- CtS TE CENTER: BLDG 7 D U © N 0 Z 44f1.1 C:\Documents and SettingsAAll UserssDocuments\CAD11987-1989\8704-71One Source Talent 200 01-29-13\T-0-T-2,dwg, T-1, 1)30/2013 10:34:54 AM PROJECT 8704-7 8 0 .i.1, Gotw 0 CHECKED BY DAVID MILE 1 i 0 La 0 E S. `4 ell g ®<1411 Z 3 Cen W Eco E Lc_ 2). fa co co 1 CSI W s- CtS TE CENTER: BLDG 7 D U © N 0 Z 44f1.1 C:\Documents and SettingsAAll UserssDocuments\CAD11987-1989\8704-71One Source Talent 200 01-29-13\T-0-T-2,dwg, T-1, 1)30/2013 10:34:54 AM - —i RELOCATE EXISTING LIGHT FIXTURES AS SHOUJN. NO INCREASE IN WATTAGE. EL IS EMERGENCY LIGHTING WITH BATTERY BACKUP. PIROOS LOO FLA\ SCALE I/s" =1' NOTE: PATCH AND REPAIR EXISTING CEILING, REPAIR GRID A5 REQUIRED, REPAIR/REPLACE DAMAGED TILE (PUT NEW IN NEW SPACE, MOVE OLD TO AN OFFICE TO AVOID NEW AND OLD IN THE SAME SPACE). RELOCATE SUPPLY AND RETURN AIR AS REQUIRED. IA — REMOVE AND RELOCATE EXISTING LIG MODIFY SWITCHING AS REQUIRED FOR NEUJ SPACES. MAX S0% OF 20 AMP CIRCUIT E1L CT C LNG 0 SCALE 1/8" =1' NOTE: LESS THAN 60% OF THE FIXTURES NEW, INSTALLED WATTAGE NOT INCREASED, 4 SPACE USE NOT CHANGED LEGEND • REVIEWED FOR CODE COMPLIANC APPROVED MAR 0 6 2013 City of Tukwila BUILDING DIVISION EXISTING WALL NEW STEEL STUD WALL TO UNDERSIDE OF CEILING W/ SOUND INSULATION EXISTING WALL TO BE REMOVED. NEW DOOR EXISTING DOOR FOUR-PLEX OUTLET DUPLEX OUTLET WALL TELEPHONE OUTLET AND DATA, MUDRING, CONDUIT AND FULL STRING ONLY. SUPPLY AIR RETURN AIR n SUPPLY AIR 2x4 WOOD STUD WALL (SEE SCHEDULE) 2x WOOD BLOCKING 2 1/2" WOOD CASING - STAINED 1 1/2" x WOOD JAMB - STAINED 5/8" x WOOD STOP - STAINED SOLID CORE WOOD DOOR STAINED 5/8" GYP BD. EACH SIDE WOOD FRAME DETAIL SCALE: 1-1/2" = 1'-0" BLACK TRACK ALUMINUM BREAK METAL CUT BOTTOM SNAP- IN ALUMINUM 9 FRAME TO ALLOW GLASS CHANGING GASKETS 1/4" INFILL WITH Woo UJIALL TO UJINDOUJ SCALE: 1-1/2" = 1'-0" SECTION SILL BELOW DEEP LEG TRACK ATTACH a SILL AND CEILING GYP. D. TO STEEL TRACK PROVIDE 1/2" AIR SPACE TO STEEL STUD AND ATTACH GYP. BD. TO STUD TAPING COMPOUND OVER PAPER -COVERED CORNER BEAD. SECTION FOR WALLS GREATER THAN 8'- 0" IN WIDTH WITHOUT AN INTERSECTING WALL, PROVIDE I2ga. WIRES SPLAYED 6 45 TO AN EYE SCREW 6 ROOF AND TOP OF UAL 0 V' v EXIT ►.1 —71 E N EL J -BOX FOR POWER AND/OR PI-IONE ILLUMINATED EXIT SIGN W/ PATHWAY LIGHTING 2' X 4' EXISTING 3-TU1SE FLUORESCENT (88 WATTS) 2' X 4' NEW OR RELOCATED 2 -TUBE FLUORESCENT (66 WATTS) 2' X 4' NEW OR RELOCATED 3 -TUBE FLUORESCENT (66 WATTS) 2' X 4' EXISTING 2 -TUBE FLUORESCENT TO REMAIN (66 UJATTS) 2' X 2' NEW OR RELOCATED 2 -TUBE FLUORESCENT (66 UJATTS) 2' X 4' EXISTING 3 -TUBE FLUORESCENT TO BE REMOVED AND STORED OR REUSED EXISTING NEW DEDICATED SWITCH EMERGENCY PATHWAY LIGHTING, ADD BATTERY BACK UP TO NEW/EXISTING LIGHTS ATTACH TOP RUNNER TRACK TO CEILING GID WITH 2 - 06 x 1 I/8" LONG SCREWS AT 2'-0" O.C. ■■■■■■■■■■■■■■■■■r'�■■■■■■■■■■■► 111 TYPICAL STUDS UALL PER SCHD. (FOR WALL INSULATION SEE PLAN) 5/8" GYP. BD. EA. SIDE (FLUSH FINISH). SEE REFLECTED CEILING PLAN TIP. UJ,4LL TO REFLECTED CEILING SCALE: I-1/2" = I'-0" TYPICAL WALL FRAMING ATTACH BOTTOM TRACK TO CONC. FLOOR W/ POWDER DRIVEN ANCHOR5, HILTI OR APPROVED 1" EMBEDMENT AT 24" O.C. 2 1/2" RUBBER — BASE 6 CARPET 5/8" GYP. BD. (TYPE 'X' 6 FIRE RATED WALLS. ACOUSTICAL BLANKET * SOUND WALL. CONC. SLAB ON GRADE WALL TO SLAB SCALE: 1-1/2" = I'-0" PAINT BLACK 3/4" x 2" FILLER BLACK GASKETS 1/4" EACH SIDE OF FILLER CAULK GYP. D. TO FLOOR 6 ALL SOUND AND INSUL. WALLS SILL BELOU DEEP LEG TRACK ATTACH 9 SILL AND CEILING - DO NOT ATTACH GYP. BD. TO TRACK STEEL STUD - ATTACH GYP. BD. rl 13 -Oso UJ,4LL. TO MULLION SCALE: 1-1/2" = I'-0" SECTIO SECTIO RECEIVED CITY OF TUKWILA FEB 2 6 2013 PERMIT CENTER SECTIO PROJECT 8704-7 DRAWN BY kehle DATE 01-29-13 CHECKED BY DAVID KEHLE DATE — DESCRIPTION 1,-_ Lt f E m 0 a ©©® CO CO M N CO CD 0 N vv Cl)Qc QQ Z3I— M/O� • co (01— ZX �W G. LL. 0) IFA:922= • GATEWAY CORPORATE CENTER: BLDG 7 2 C:\Documents and Settings\AII Users\Documents\CAD\1987-1989\8704-7\One Source Talent 200 01-29-13\T-0-T-2.dwg, T-2, 1/30/2013 10:37:36 AM