Loading...
HomeMy WebLinkAboutPermit M13-053 - FUSE NETWORKS - REPLACE ROOF TOP UNITS This record contains information which is exempt from public disclosure pursuant to the Washington State Public Records Act, Chapter 42.56 RCW as identified on the Digital Records Exemption Log shown below. M13-053 Fuse Networks 12628 Interurban Ave S DIGITAL RECORDS (DR) EXEMPTION LOG THE ABOVE MENTIONED PERMIT FILE INCLUDES THE FOLLOWING REDACTED INFORMATION Page # Code Exemption Brief Explanatory Description Statute/Rule The Privacy Act of 1974 evinces Congress' intent that social security numbers are a private concern. As such, individuals’ social security Personal Information – numbers are redacted to protect those Social Security Numbers 5 U.S.C. sec. individuals’ privacy pursuant to 5 U.S.C. sec. DR1 Generally – 5 U.S.C. sec. 552(a); RCW 552(a), and are also exempt from disclosure under section 42.56.070(1) of the Washington 552(a); RCW 42.56.070(1) State Public Records Act, which exempts under 42.56.070(1) the PRA records or information exempt or prohibited from disclosure under any other statute. Redactions contain Credit card numbers, debit card numbers, electronic check numbers, credit Personal Information – expiration dates, or bank or other financial RCW 60 DR2 Financial Information – account numbers, which are exempt from 42.56.230(5) disclosure pursuant to RCW 42.56.230(5) RCW 42.56.230(4 5) , except when disclosure is expressly required by or governed by other law. FUSE NETWORKS 12628 INTERURBAN AV S M13-053 City ahukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0004800003 Address: 12628 INTERURBAN AV S TUKW Project Name: FUSE NETWORKS Permit Number: M13-053 Issue Date: 03/18/2013 Permit Expires On: 09/14/2013 Owner: Name: GATEWAY OLYMPIA INC Address: PO BOX 4900 #207 , SCOTTSDALE AZ 85261 Contact Person: Name: DAWNA PETET Address: 899 W MAIN ST , AUBURN WA 98001 Email: DAWNAP@SEATTLEMECHANICAL.COM Contractor: Name: IECS INC. Address: P.O. BOX 19252 , SEATTLE, WA 98109 Contractor License No: IECS***044QL Phone: 253 939-9495 Phone: 206 939-9495 Expiration Date: 11/20/2014 DESCRIPTION OF WORK: ADD (3) NEW ROOFTOP HVAC UNITS. INSTALL EXHAUST FANS FOR LUNCHROOM AND (2) NEW RESTROOMS. PROVIDE DUCT SYSTEMS FOR NEW OFFICE AREA. Value of Mechanical: $10,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complied Fees Collected: $306.06 International Mechanical Code Edition: 2009 Date: amin-d this permit and know the same to be true and correct. All provisions of law and ordinances 'th, hether specified herein or not. The granting of this permit does not pres e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Date: 34 g-13 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. ...-. 11A!" A14" RA4'A AC 1 D...de.l• A1_1111_O/111 PERMIT CONDITIONS Permit No. M13-053 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doe: IMC -4/10 M13-053 Printed: 03-18-2013 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov • Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: 02)17g 3 PC 11 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION /1444K King Co Assessor's Tax No.: 000410 0 0 0 Site Address: /09-6(9t 8 11 r' ur bical totoeSD s Suite Number: _ Floor: Tenant Name: ) SC n f yS New Tenant: i Yes ❑ ..No PROPERTY OWNER Name:6 iLe toad6I yifis Tryr Address:/0/ ca/i.(rlG_y'- -Plow City/If1 c SCOState: 04 Zi 111 CONTACT PERSON — person receiving all project communication II '' q t ay- ( Name:/,hr0s to k / uomp.Q,%'i' Address:: scri lio ►VI's 0. .v`J S . 0153136 City: illi. State `' Zipb1RODi Phone: 0N / 'r S- O2.., _fax: 0153—Q. - . 6.1) Email: _ nr di risc..rJ(d s-ea-l - 2.117.ee [lX ti) MECHANICAL CONTRACTOR INFORMATION G{ __iii, /► _ Company Name:x5 J 10 ' r Address: qq IV , , , lnwL .. D U & City: , %lam 1 PhoneG ,...t3 9l/4T7 Ea x:0158` -q 0 Conteg _No 4 w_Q 1..... Exp Da/f: ^ / 3 Tukwila Business License No.: p) ,s ... Onnop b -9'95 e.G : da wlnq rpe1)&a ico Q . tan Valuation of project (contractor's bid price): $ (0, 000 . 00 Describe the scope of work in detail: ktd. 3 (J W ROaOap 14vel-c, USL-ks . E44&us+ Fps For ILA -AA roam ; a hew r-ese-rn.s P -v gat-ck\k 4 5y54-- Aims for 1w3 o Use: Residential: New ❑ Replacement ❑ Commercial: New ¶I Replacement Fuel Type: Electric Gas 91 Other: H:Wpplications\Forms-Applications On Lme2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI NER OR AUAIOVIZED A ENT: q Signatur )0041 'L L5't1 L (keen ?O Date: ' i 3 Print Name: wfut Mailing Address: S 1 ; Mai& 5± Day Telephone: 0?53 9 3q - H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh City State Zip Page 2 of 2 C* of Tukwila, Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R13-01069 Initials: JEM User ID: 1165 Payee: IECS, INC. Payment Date: 03/18/2013 Total Payment: 341.45 SET ID: 0318 SET NAME: FUSE NETWORKS SET TRANSACTIONS: Set Member Amount M13-053 244.85 PG13-032 96.60 TOTAL: 2T2171113— TRANSACTION LIST: Type Method Description Amount Payment Check 54014 341.45 TOTAL: 341.45 ACCOUNT ITEM LIST: Description Account Code Current Pmts GAS - NONRES 000.322.103.00.0 MECHANICAL - NONRES 000.322.102.00.0 96.60 244.85 TOTAL: 341.45 SET RECEIPT RECEIPT NO: R13-00960 Initials: JEM User ID: 1165 Payee: IECS, INC. Payment Date: 03/05/2013 Total Payment: 85.36 SET ID: S000001938 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount M13-053 61.21 PG13-032 24.15 TOTAL: TRANSACTION LIST: Type Method Description Amount Payment Check 53922 85.36 TOTAL: 85.36 ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 TOTAL: 85.36 85.36 INSPECTION NO. INSPECTION RECORD Retain a copy with permit rn3-653 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Project: 81WOR S Type of Inspection: } Ir..iAi._ Address:Date ! 2-(29 _%-NI;i.Q11Rt,ik1 Called: Special Instructions: Date Wanted:. 3 -13 a.m� p.m. Requester: Phone No: l•Approved per applicable codes. El Corrections required prior to approval. COMMENTS: 4)efir i --franvt - 4' //7--a/4 r: Dat_ ErEINSPECTION FEE REQUIRED. Prior t9 ext inspection. fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. CITY OF TUKWILA BUILDING DIVISION7/,' 6300 Southcenter Blvd., #100, Tukwila. WA 98188 e-. (206),431-3670 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD Retain a copy with permit 613-653 PERMIT NO. Project: t-- .1N‘CIV OR14 i Type of Inspection: Q.01t6i-1 —.11N/1 Address: 1 P.4, -2—P) % 1 Q. Date Called: ?J Special Instructions: Date Wanted:. 3 ---ick ..i2) , a€ .m': p.m: Requester: Phone No: ,a_533 r ft^y LIC [pproved per applicabletcodes. Corrections required prior to approval. COMMENTS: t,r t RAnr1; ; 7(LI t4 --)J_' (N f� r6.de csle jisspectoi r7REpi pa, at f . ECTION FEE REQIJ\RED. Prior to n xt inspection, fee. must:be; 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Date: CT ENGINEERING INC. 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206) 285-0618(F) STRUCTURAL CALCULATIC� - ettrol1 New RTUs and Window Openings Fuss Networks at Tukwila Commerce Park Building C: 12628 Interurban Ave. Tukwila, WA Scope of Work: Provide support as required for (2) 5 -Ton and (1) 3 -Ton roof top mounted mechanical units. Design lateral support system from seismic forces. Design two window openings in the exterior concrete wall. Code: IBC 2009 Edition Loads: Snow 25 PSF Wind 85 MPH, Exp B Seismic SDs= .986 Structural Engineers REVIEWED FOR CODE COMPLIANCE APPROVED MAR 1 3 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 0 5 2013 PERMIT CENTER MLrO3 C T ENGINEERING Project• FOSC klel*lor1 1 N C. Client: L.: F.-k(s11'r4 cl : 1\ Q- - - 4 ►- / • T-lluroRti l Date: Page Number; 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 PAX: (206) 285-0618 ►o 1o00 •3I4aL-43 SNo.) S(15+- ) or WO S3. zo `VI, : -F - . 1 T = to -64 ��. c) MoD 5\(e S _ �`15,`i.5 I.& .. s Q` Tett ?.l _: 157. rb\. b 19 mob . . 4 lt—IL t1114Lew Go° ' Structural Engineers C T ENGINEERING Project: FvsE- ► 12.e— 1 N C. Client: Date: 74/1.3 Page Number: 2 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 PAX: (206) 285-0618 Structural Engineers C T ENGINEERING INC.1' Prolcct: FVS iE1\11/Cf ..S Tuk.WILI Client: Date: u/�3 2124 Page Number: Sy-_` 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 PAX: (206) 285-0618 Structural Engineers C T ENGINEERING �` `' 1NC. -SSS Project: NI1 �J00.X 1614—Ni t ll -44 Date: 21243 Client: Page Number: e' 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 rAx: (206) 285-0618 Structural Engineers C T ENGINEERING 1 N C. Project: FO Sim K�1 \ luta - ` TOV Client: Date: z/ zo'i3 Page Number: 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 PAX: (206) 285-0618 Structural Engineers C T EN GIN EERING 1 N C. Project: Fi N���n10 S — TukwfL/� Client: u/�3 Date: a/20(13 Page Number: SiV-- 1 180 Nickerson St. Suite 302 Seattle, WA 98109 ' (206) 285-4512 FAX: (206) 285-0618 Structural Engineers C T ENGINEERING I N C. Project: FOSS' NE:1W01 .— TikwI1..% Client: Date: 2-1W`i , Page Number: 6 14'2. 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 Z7CToik FL5 2$' i'660ele- Nc,. 01417 Nv1c.N Z7,10 dk"10 ls S c 2am s S I. U NI 11 e :CvnPS Ml.l 8.• � Lurr To n2x4- LE' PuRLi)a (..-) s7E►- a o)s a., o Structure! Engineers C T ENGINEERING Project: INC. Z) 5 twE.1 v� — Tuk.m Lat.. 2122113 Date: 70/13 Client: Page Number: 516-3 180 Nickerson St, Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 Structural Engineers C T ENGINEERING �`INC. Project: FU Se" NE-114°Q.� TUV--\#41(LA• Date' -2/70/t3 Client: Page Number: S 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285.4512 FAX: (206) 285-0618 • • • .1/1{-k 3:y. 0`,.% vi/ a- Ye 4))0; S rthc.Lcs. , 0 I -s$ 4 4x1 •,, 3=c�: to 3/8:.)..492.74.c.1 -1:o " - W/ 2-V2 4>r 3 TITMN Hip Structural Engineers SUBMITTAL Project Untitled 17 Date Wednesday, February 13, 2013 PI�F COPY REVIEWED FOR CODE COMPLIANCE APPROVED MAR 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 0 5 2013 PERMIT CENTER Project:-Untitledl7 Prepared By: Table Of Contents 02/13/2013 12:52PM 5 Ton.. Unit Report ............ . Certified Drawing ............... Performance Summary..... . Unit Feature Sheet . ... . . 3 Ton ............ .. ....... Unit Report ........... . Certified Drawing ......... . Performance Summary.... Unit Feature Sheet ............. 3 4 5 8 11 12 13 14 17 20 Packaged Rooftop Builder 1.34 Page 2 of 20 Project:-Untitledl7 Prepared By: 5 Ton 02/13/2013 12:52PM 5 Ton Tag Cover Sheet Unit Report Certified Drawing Performance Report Spec Sheet Unit Feature Sheet Packaged Rooftop Builder 1.34 Page 3 of 20 Project:—Untitledl7 Prepared By: Unit Report For 5 Ton 02/13/2013 12:52PM Unit Parameters Unit Model: 48TCDA06A2A6-0A0A0 Unit Size: ............ ...... 06 (5 Tons) Volts -Phase -Hertz: . 460-3-60 Heating Type:. Gas Duct Cfg:.... .. Vertical Supply / Vertical Return Low Heat Round Tube Plate Fin Coils Lines and Filters Gas Line Size: ..... ....... Condensate Drain Line Size: Return Air Filter Type:.... Return Air Filter Quantity: Return Air Filter Size:.... Unit Configuration Medium Static Option AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging 1/2 3/4 Throwaway 2 16x25x2 Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (Ib.) •.t Unit Length:. ........ Unit Width:....... ... Unit Height: ............. ••• Total Operating Weight: .. .... 6' 2375" 3' 8" T 9375" 744 Ib "' Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA06A2A6-0A0A0 Rooftop Unit 2 Accessories CRECOMZR020A02 Vertical EconoMi$er IV with solid-state controller 2 CRRFCURBOOIA01 14 -inch Tall Roof Curb 2 Packaged Rooftop Builder 1.34 Page 4 of 20 Project: -Untitledl7 Prepared By: Certified Drawing for 5 Ton 02/13/2013 12:52PM NOTES: 1. DINEN5I005 ARE IN INCNES DIMENSIONS IN 1 1 ARE IN MILL(M010 S. 2. S CENTER OF GRAVITY 3. MO. DIRECTION OF AIR FLOW UNIT 48TC-ADA 33 3/5 (8471 185/5 11721 48TC-505 33 3/8 (8471 141/5 13711 487C -A06 33 3/8 (8/47 147/5 13171 481C -A07 41 3/8 11051] 14 7/8 13711 FILTER ACCESS PANEL (TOOL-LE531 - COMP. ACCESS • PANEL ' 0 •_ CONDENSER COIL 1 INDOOR COIL ACCESS PANEL t ,r a (1(3 tTI 1T1 7 � BACK 2-5/5 1611 TOP CURB WIDTH 44 4-5/8 11181 LECTRICAL DISCONNECT LOCATION OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET 10-1/2 144/ 3-3/4 (951 463/4 LEFT 33 are 18/51 0 UNITED 1.0, 00I 4506 TECHN0106(E511uau, 11 CARRIER 15011 1 1 0 (0 553N1Y11E1[0 4005 115*5555055]11ACORPORATION 1 5r1 15411111 rlll 1011[ DG5l01D OR5 UN[0 /ITNOR 15RA7[0 10000151101 01rr11 1015111. NLNNI1IION 0r 1505[ 1511110 54 001010111 0010 001 101111010 0511 I[1101AIOR 011 51110151[[ a 10110101. ECONOMIZER HOOD (OPTIONAL) 1 SEE THRU THE BASE CHART 25 (6361 —^ 25-5/8 —� 16521 RETURN AIR 16 14061 10-7/8 (2771 4. RETURN AIR 0 E ALT. J CONDENSATE DRAIN OPENING IN BASEPAN 17-3/4 (1511 SUPPLY AIR 6. 7A J1571 / —i LH (1001 /4000 TOP 12-1/6 13071 18-1/2 --�. (4701 CONTROL BOR ACCESS PANEL INDOOR BLOWER ACCESS OPTIONAL FACTORY INSTALLED DISCONNECT HANDLE (18581 FRONT 26-1/2 (6737 21-3/6 (7611 SUPPLY AIR 3-3/5 (851 THRU-THE-BA E CHART THESE HOLES 6102)600 FOR USE CRBTMPWR001A01, 003A01 CONNECTION SIZES A 1 3/0' 1351 DIA FIELD POWER SUPPLY HOLE B 2' (501 DIA POWER SUPPLY KNOCKOUT C 1 3/4' (511 DIA GAUGE ACCESS PLUG 0 1/8' 1221 DIA FIELD CONTROL WIRING ROLE E 3//'-11 NPT CONDENSATE DRAIN F 1/2'-11 680 GAS CONNECTION G 2 1/2 ' (611 DIA POWER SUPPLY KNOCK -OUT THRU-THE-BA E CHART THESE HOLES 6102)600 FOR USE CRBTMPWR001A01, 003A01 THREADED WIRE 600'D HOLE CONDUIT SIZE USE SIZES 1MA6.1 N 1/2' ACC. 7/8' (12.27 I 1/2' 24V 7/8. 122.21 1 1 3/4' 1001,0031 POWER 1 1/8. 128.41 215 (0031 1/2' FPT GAS 1 3/16' 130.01 FOR 'THRU-THE-DASEPAN' FACTORY OPTION FITTINGS FOR ONLY 2,1, 1 2 ARE PROVIDED SELECT EITHER 3/4' OR 1/2' 0 FOR POWER, DEPENDING ON WIRE SIZE 5110011 PROVIDES 3/4' FPT DOWCURB FLANGE 6 FITTING. 11-3/8 OUTSIDE AIR 401111 21-1/4 15311 17931 SUPPLY AIR 4061355 RIGHT BAROMETRIC RELIEF FLOW SKIT 10F2 011 11-24-08 10(1111011 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48714500993 5.0 Packaged Rooftop Builder 1.34 Page 5 of 20 Certified Drawing for 5 Ton Project:-Untitledl7 Prepared By: 02/13/2013 12:52PM UNIT STD. UNIT WEIGHT CORNER WE1GN1 (41 CORNER WEIGHT 181 CORNER WEIGHT ICI CO NER WEIGHT (DI C.G. HEIGHT L85. K0, LBS. KG. LBS. KG, LBS. KG. LBS. KG. 8 T 2 491C -*04 463 211 111 50 125 51 131 59 111 53 30 [9911 23 (5841 16 3/8 [1111 481C -A05 531 244 124 56 139 63 145 86 129 59 39 (9911 23 (5841 17 (4321 481C-606 569 256 131 58 141 67 154 70 137 62 39 (9911 23 (5841 17 1/4 04361 487C-407 852 296 150 68 169 76 176 80 157 71 39 09911 23 25841 20 1/8 (5111 CORNER A TOP 1 CI 00 0 UNITED I.D. ICI OOP TECHNOL061ES Minn, 8T CARRIER ,8n1 TNII 80(25011 15 TIE 001(111 0 an1E1 0080811101 115 I5 1(1InI8 0701 116 I51DEu 10/810108 5X.11 171 C01E115 8511 107 1E 81581(0 0 5058 015x1(1 (0808085[5 02008A1101 5591710 (28(11. 31.41111/1011 01 0158[ 81A70185 0 OCU12nS 01(5 NOT (08511T01E PANT rc1/0ANINCT m ACCEPT/AI Of (0118011. CORNER 8 CORNER C FRONT MET 2 OF 2 m0E 11-24-08 501(1(11(5 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 481M500993 5.0 Packaged Rooftop Builder 1.34 Page 6 of 20 Certified Drawing for 5 Ton Project:-Untitled17 Prepared By: 02/13/2013 12:52PM RCCFCURIJ ACCEESCRYA A aaau1em11m AOt 24 �+rn I1 1 14 NTMES 1 2187AT®Ra85 MTWYCLYL/ETM8EFOWAM1$1346Ma•G1IY APCCR1f8t8C,AC SIS 5AT7 rDN. �TnrFAasnE . A10P10FAAC sfcRntalT76Cl.R8GASIYPE pADRIECREITMANRIPAOUSFCRIMILRFERTIMTATIPEGISMAI,ECTIONS 5A2 1137.71 1 21.74 MA 1} P —� 11B Pmol 1 1 s- l 498 J 7087* Sema 19 1r".-2124.E oPe�lG �4'44 E t 3219 1 f Fe 1 1 � 9-FPLYAR c�+�G 1 1 21 1877LI 1.75. E 1_2141 --4.. 81831 0099 — 3DP 1179 P534 CORNERDETAL GASOOJ 2C11CF 1'PE POA6NR3G RTT7•C OONIRCUAIR JC FMNG ACCECCCRICCNVDECE CUTLEMAIRNOON=iOR 3'4S91PPT nnmEEorTCR4 12p2.11141 311i13PPT 1/2112.71WT 12t12.7PPT 1+11314 sEc11oN E E 41U Fm4 A IM1•031101r41S/@ NaMPm19NDOUNRc9 ffHD31718a tm t M.0 11311/25851wfE 731ATMES 8918 2I75JW87E ►31A713:CEO4PMEL SEE VIEW"B" CERWEDDRAWNG 57-718" n72191 1314" ORANNORBFAYtEN1 PRODUCTION 11YOMliE 11011 1AA19a"L RI4E900ERWSESEis® W6BpR4FRaaiNETEJa lusty 6nw SLIPS: 2QFS 21£6 !!2 .1 "1A *OS 12' Cala AURedTeYrbbjesCmpsy TaaoaAaR RDRIERlo Awric )vrtNW11EREN ispfrpREraRyitrAPAIEROMKR.,1O1N69M11Of rTQrn£ARIII.V. ICWAna4i A A1111O VA11W11ffA 1041738 EtoREERNOMoIRElen T -005•Y-002 vN.F.Cita o SY,Ra r 153400 EfurrER A4c 011701 1NEoaA ERE D oRayitatAAam 4 mom 565 REV A OR2 REV REMYWRE00f0 [ATE 5.. oc•0 Wf..5 arwln AVRACER®1j AfTAIOI I tel/ IEEtxn PetTORAVANO Nr. osIRanICN Packaged Rooftop Builder 1.34 Page 7 of 20 Project:—Untitledl7 Prepared By: Performance Summary For 5 Ton 02/13/2013 12:52PM Part Number:48TCDA06A2A6-0A0A0 ARI SEER:.... Base Unit Dimensions Unit Length:.. Unit Width: Unit Height:. Operating Weight Base Unit Weight:......... ........... Medium Static Option:. Accessories Vertical EconoMi$er IV with solid-state controller: 14 -inch Tall Roof Curb: Total Operating Weight:.. Unit Unit Voltage -Phase -Hertz:.. Air Discharge: Fan Drive Type:.. ... . . Actual Airflow:... .... Site Altitude:......... .. .... .. Cooling Performance Condenser Entering Air DB:.. .. . Evaporator Entering Air DB:... . . Evaporator Entering Air WB:... . .. Entering Air Enthalpy: .. Evaporator Leaving Air DB:... . .. Evaporator Leaving Air WB:.......... Evaporator Leaving Air Enthalpy:... Gross Cooling Capacity:...... .. . Gross Sensible Capacity:. .. ...... Compressor Power Input:... .. . Coil Bypass Factor:.... 13.00 74.4 in 44.0 in 33.4 in 569 Ib 10 Ib 50 Ib 115 Ib 744 Ib 460-3-60 Vertical Belt 2000 CFM 0 ft 95.0 F 80.0 F 67.0 F 31.44 BTU/lb 57.9 F 57.3 F 24.56 BTU/Ib 61.90 MBH 47.70 MBH 4.43 kW 0.055 Heating Performance Heating Airflow: 2000 CFM Entering Air Temp:..... 70.0 F Leaving Air Temp 97.3 F Gas Input Capacity72.0 MBH Gas Heating Capacity:... 59.00 MBH Temperature Rise:.... ... 27.3 F Supply Fan External Static Pressure - Options / Accessories Static Pressure Economizer:... Total Extemal Static: Fan RPM:... Fan Power:..... NOTE:...__ ... ........ . . 1.00 in wg 0.12 in wg 1.12 in wg 1442 1.64 BHP Selected IFM RPM Range: 1035 -1466 Electrical Data (Before July 30, 2012) Minimum Voltage:.. 414 ............ . Maximum Voltage:...... 506 Compressor RLA• 7.7 Compressor LRA 52 Outdoor Fan Motor Qty: 1 Packaged Rooftop Builder 1.34 Page 8 of 20 Project:-Untitledl7 Prepared By: Performance Summary For 5 Ton 02/13/2013 12:52PM Outdoor Fan FLA (ea)' Indoor Fan Motor Type:. Indoor Fan Motor FLA:.... ... Combustion Fan Motor FLA (ea): Power Supply MCA: ............. ............ Power Supply MOCP (Fuse or HACR):. Min. Unit Disconnect FLA:. Min. Unit Disconnect LRA:... Electrical Convenience Outlet: Electrical Data (July 30, 2012 and Beyond) Indoor Fan Motor FLA: Power Supply MCA: .. . Power Supply MOCP: Disconnect Size FLA: Disconnect Size LRA: 0.8 MED 2.6 024 13 20 13 69 None July 30th and beyond units can be identified by serial number 3112XXXXXXXXX and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 89.6 88.5 84.0 125 Hz 84.6 81.9 82.2 250 Hz 78.1 69.3 76.3 500 Hz 73.6 65.9 74.8 1000 Hz 69.9 65.0 72.5 2000 Hz 64.7 59.5 68.8 4000 Hz 66.5 55.2 65.6 8000 Hz 62.2 48.7 61.8 A -Weighted 77.0 71.3 78.0 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground- 30.0 ft 2. Horizontal distance from unit to receiver: 50.0 ft 3. Receiver height above ground:... 5.7 ft 4. Height of obstruction 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information 3.4 14 20 14 82 Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k Overall Sound Power Levels at Unit's Acoustic Center (Lw), dB 84.0 82.2 76.3 74.8 72.5 68.8 65.6 61.8 87.2 Lw A -Weighted Sound Power Levels at Unit's Acoustic Center (LwA), dBA 57.8 66.1 67.7 71.6 72.5 70.0 66.6 60.7 77.7 LwA Sound Pressure Levels at Distance Specified above (Lp), dB 51.6 49.8 43.9 42.4 40.1 36.4 33.2 29.4 54.8 Lp A -Weighted Sound Pressure Levels at Distance Specified above (LpA), dBA 25.4 33.7 35.3 39.2 40.1 37.6 34.2 28.3 45.3 LpA Packaged Rooftop Builder 1.34 Page 9 of 20 Project:—Untitled17 Prepared By: Performance Summary For 5 Ton 02/13/2013 12:52PM Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. 20 18 16 GI 02 FanCurve 03 C6 Q9 12 15 Actbw(CFM-th cusands) RPM= 1442 BHP= 1.64 MaximumRPM= 1466MaximumHP=2.90 Note: Please contactapplica1ion eeringforselectionsoutsidetheshadedregion. SC-SystemQnveRP-RatedPoint 18 21 24 27 Packaged Rooftop Builder 1.34 Page 10 of 20 k w a - r ylr •`1.4...- 1100RFN1 4 " \ Ido % /.. . \ t \� soORFiv1• 11�„ a ° a 3.00BHP 70(iiPM ��� a tss U75BHP ° It 00BIfl t 1 1 1 I --- I \m _ 4. _ j�1 2:t nE .; \_ :. J1 , I' ' 11 1' _ _ L 03 C6 Q9 12 15 Actbw(CFM-th cusands) RPM= 1442 BHP= 1.64 MaximumRPM= 1466MaximumHP=2.90 Note: Please contactapplica1ion eeringforselectionsoutsidetheshadedregion. SC-SystemQnveRP-RatedPoint 18 21 24 27 Packaged Rooftop Builder 1.34 Page 10 of 20 Project:—Untitledl7 Prepared By: Unit Feature Sheet for 5 Ton 02/13/2013 12:52PM WeatherMaker — 48TC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 3, 4, 5, 6, 7.5, 8.5, 10, 12.5, 15 TONS Optional Louvered Hail Guard Showa WEATHERMAKER SERIES WeatherMaker(48TC) units are one-piece gas heating, eledric cooling units that are pre -wired and charged with Puron (R-410) refrigerant They are factorytested in both heating and cooling modes, and rated in accordance with AHRI Standards 210/240(04-06 sizes) and 340/360 (07-16 sizes). WeatherMaker units are designed in accordance with UL Standard 1995, and listed by the Underwriters' Laboratories. Approved and certifiedby: us Certified to ISO 9001 STANDARD FEATURES INCLUDE: • Phan (R-413A)HFC ref event • AS$ RAE33.1 tnerayoomolsni • ScroI comoressos wan internei b eskand ovenoad protection • 5;n;4 -stage coo ling cepoorly cont•oion•34.12model • Two-stspecorAngcepa aayxnt.cron09.15models • SEER3 up to 13:3. EER's up to 11.1 end IEER's up to 11.9 • Acuter?". re frlaemni.metering systern • Exc.:11we npngprros!ve compai tecondensete pan in 1071rdanae a�th ASHRAE Standa+d 52. sipping desian, side orcanterdrain • Stanch Jcpcenaoperstion up to 115'F;46'C; and down to 43'F - down to 25'F (4' C; %with winter start kit. • P•e-o•intedextera:pane!send prime•-:astad intoro•pane 4tested to 533hours silt spray protection • F,, 1nautstedeabinet • ExpusiveIGCsold-stet trontro'fpror+-boald°agnastios'.w1hLEC er.-orcodedesianstian bumercont•ol49c .id .r.y,J v19 indoo• fen nobrdeSty • LowI'3x model that meet fora A r aua`ty Management • Induced d7ftgoo heat combustion design • Red,ndent gas valves wan Jp 10 nvo stages of heating • Low prase;!le and pian p!essu:e switch p'ptect.ed. MAINTENANCE FEATURES: • Amos* panels with essygrio handles • Innovative •asy'starting, no -stet.) s0IDwi on tint sooess pane'; • Two -incl d1posab7e atum air files and To!asss f114. 80x55 dap! • Belt dri'eevaoorstor-fan motor and ouiaycombinations • 1 ewterminai boardfaclitat:ng simo4 safelycirciii4 troJbieshpotin•a and s!rnpifed contra; box arrangement • ExoiJave1Gt; said -state contro:for on-boarddiagnostics with LEC em7rcodedes, nation• burnercontrp!hgo and energy saving indoor fan rrotordelay. IN STALLATION FEATURES: • Th a cine-4attompawsrentrycapsbiidy. • Singe point gots and eectr. connections • Furpenrnster base roil wlh built-in nag 'mg ad aptens and fork vats • F40 convertibefom venicai to norzo nteiaiihw for slab mounting. (15 sit models require fetid instaratd supply duct cover;. STANDARD WARRANTY: • l3yeerhest exchlinger -15-yearsts:nessstee option • 5•yearcompressa• • 1 -year parts • 3yearports on IdovationCondense•coys-where sysi!abe • Msnyoptians' upgrades also available OPTIONS INCLUDE BUT ARE NOT UNWED TO: • PrernerLrnk"' and TR/ Open Multi Protocol DCC Contra's • Suoo!ysnd Return Air Smoke Ceteotors. high state. motors • Louvered oondensercoilguards • Econom¢er. daconnect and convenience outlet options • Sts iniessSteel hest excite nae•opt'on • Carrosion.raextent 'L costing. • Hu mid i-lel2er• ads obi. deh timidfcetion systemaysiiabie on all modelswrth R7PF condtneer cors - Motor Master Icont•oter incLided • singed gooses pane3 Fo• a compete list of options and aoaestones refer to the ProdJN Cats C01s1ag fortnib unit. Packaged Rooftop Builder 1.34 Page 11 of 20 Project:-Untitledl7 Prepared By: 3 Ton 02/13/2013 12:52PM 3 Ton Tag Cover Sheet Unit Report Certified Drawing Performance Report Spec Sheet Unit Feature Sheet Packaged Rooftop Builder 1.34 Page 12 of 20 Project:—Untitledl7 Prepared By: Unit Report For 3 Ton 02/13/2013 12:52PM Unit Parameters Unit Model :.. ...... .. ...... . 48TCDA04A2A6-0A0A0 Unit Size 04 (3 Tons) Volts -Phase -Hertz: . 460-3-60 Heating Type: Gas Duct Cfg:.... . Vertical Supply / Vertical Return Low Heat Round Tube Plate Fin Coils Lines and Filters Gas Line Size:. . . . . Condensate Drain Line Size: Return Air Filter Type:. Return Air Filter Quantity:. Return Air Filter Size: Unit Configuration Medium Static Option AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging 1/2 3/4 Throwaway 2 16x25x2 Warranty Information 1 -Year parts(std.) 5 -Year compressor parts(std.) 10 -Year heat exchanger - Aluminized(std.) No optional warranties were selected. Dimensions (ft. in.) & Weight (Ib.) *** Unit Length :...... _ .. . _ . _ ........... .....6' 2.375" Unit Width:. 3' 8" Unit Height:.. 2' 9.375" *** Total Operating Weight:. . .... . 658 Ib *** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDA04A2A6-0A0A0 Rooftop Unit 1 Accessories CRECOMZR020A02 Vertical EconoMi$er IV with solid-state controller 1 CRRFCURBOOIA01 14 -inch Tall Roof Curb 1 Packaged Rooftop Builder 1.34 Page 13 of 20 Project:-Untitledl7 Prepared By: Certified Drawing for 3 Ton 02/13/2013 12:52PM NOTES: 1. DIMENS1ONS ARE IN INCHES DIMENSIONS INE 1 ARE IN MILL(I*0t0 S. 2. S CENTER OF GRAVITY 3. • DIRECTION OF AIR FLOW U1[13 /BTC -A01 33 3/8 [847] 18 5/8 [1121 18TC-A05 333/8 [8471 147/8 13771 48TC-806 33 3/8 [847] 147/8 [3111 18TC-A07 41 3/8 [10511 14 1/8 [371) FILTER ACCESS PANEL (TOOL -LESS) COMP. ACCESS • PANEL 0 CONDENSER COII ' INDOOR COIL * ACCESS PANEL qj(7L1 ] 37 �r r OG4J BACK 2-5/8 [671 TIP CURD WIDTH 14 4-5/8 [1181 LECTRICAL DISCONNECT LOCATION OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET 19-1/2 14941 3-3/1 [851 16 3/1 111315 LEFT 32 1/4 18181 • 333/8 18481 0 UNITED P.O. 301 1306 TECHNOLOGIES nn(1AT. IT CARRIER 13221 1111 931843) 23 113 1108110/ 91 (111111 C010R103 131 11 0(31133181103 113 131423 1011110 01831 011 (0313113 RSL IDT 11 1231183(8 3 8119 I[TN03T coon (811 1*110Y !Minn. 0081110. 838111630 m 144 1183/3163 0 OOCp1[1T6 00[6 ttIPART 31NZ 93311111123 Of 0 ECONOMIZER HOOD (OPTIONAL) 18-1/6 1 1 [359] (11(18 (38311 [311I211 1 SEE THRU THE BASE CHART 16 11061 JC_ 25-5/8 1652] RETURN AIR 10-7/8 [2771 411111 RN AIR 0 E ALT. —, CONDENSATE DRAIN OPENING IN BASEPAN RJ/1 .[1571 25 [6361 1 3/4 [4511 SUPPLY AIR 11 1 26.1/2 29-3/6 1.011111' [6 3] (] 1] SUPPLY 3-3/8 / 12-1/8 (851 (3011 18-1/2 (1701 OPTIONAL FACTORY INSTALLED DISCONNECT 100 0 HANDLE 301/8 07641 - 8-3/8 743/ (18881 FRONT [2131 A THNU-THE-BA E CHART THESE HOLES 80001008 FOR USE CRBTMPWROO1A01, 003401 CONNECTION SIZES A 1 3/6' 1351 DIA FIELD POWER SUPPLY HOLE 6 2' 1501 DIA POWER SUPPLY KNOCKOUT C 1 3/4' 1511 DIA GAUGE ACCESS PLUG 0 1/8. 1221 DIA FIELD CONTROL WIRING HOLE E 3/4'-11 NPT CONDENSATE DRAIN F 1/2'-14 111,1 GAS CONNECTION 0 2 1/2 ' 1641 DIA POWER SUPPLY KNOCK -OUT THNU-THE-BA E CHART THESE HOLES 80001008 FOR USE CRBTMPWROO1A01, 003401 THREADED WIRE 9E0'D HOLE CONDUIT SIZE USE SIZES 1961.1 9 1/2' ACC. T/8' 122.21 I 1/2' 240 7/8' [22.21 3 3 3/4' 1001,003) POWER 1 1/8' [28.4] 203 (0031 1/2' FPT 6A5 1 3/16' 230.01 FOR '1X60-THE-BASEPAN' FACTORY OPTION. FITTINGS FOR ONLY I.Y. S 2 ARE PROVIDED SELECT EITHER 3/4' OR 112' P FOR POWER, DEPENDING ON WIRE SIZE 0. (001) PROVIDES 3/1' FPT TH9U CURB FLANGE 6 FITTING. 1-1/4 11-3/8 OUTSIDE AIR 40111, 21-1/4 (539] 4-5/9 11681 [111) 26 3/1 (9911 31 1/4 [1931 SUPPLY 41, AIR RIGHT 9E1389 AIR BAROMETRIC RELIEF FLOW SKEET 1 OF 2 _ 9303 11-24-08 mums 09-29-08 48TC 04-01 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 81Y 5.0 Packaged Rooftop Builder 1.34 Page 14 of 20 Project:—Untitled17 Prepared By: Certified Drawing for 3 Ton 02/13/2013 12:52PM UNIT STD. UNIT WEIGHT CORNER WEIGHT (A) CORNER WEIGHT 18) CORNER WEIGHT (C) CORNER WEIGHT (D) C.G. HEIGHT LBS. KG. L85. K6. LBS. KG. 160. N. LBS. K6. I 1 1 4810-401 483 216 111 50 125 57 131 59 116 53 39 (9111 23 (5811 11 3/8 11161 4510-405 537 244 124 56 138 63 145 66 121 59 38 (9111 23 (5841 17 (4321 481C -A06 569 258 131 59 147 67 154 70 137 62 36 (8911 23 (5841 17 1/4 (1381 41TC-407 652 296 150 68 161 76 176 BO 157 71 31 (9811 23 (5841 20 1/8 05111 CORNER A TOP :100 1 : oo UNITED P.O. /05110/ TECHNOLOGIES ITMCISE. 11 CARRIER 11121 11)5 10001E11 11 TIE 5101(111 05 0A111E1 ttl10..110. 111 12 0[(11(1(5 0555 TIE [IMES/ 105011155 TMl1 TME OMITS RILE 101 If DISCLOSED 01 01(0 RITI011 CAM11(1 CORMAT101.1 51111(1 COMP. 155/111155 01 01150 11A111W 55 0000RI11 0010 MOT COI1T11u11 FAIT MIT5511MCE 55 A10EM ICE 01 C55TIACT. CORNER B CORNER C FRONT 351E1 2 O 2 _ DAT( 11-24-08 l*F[ICEDEI 09-29-08 48TC 04-07 SINGLE ZONE ELECTRICAL COOLING WITH GAS HEAT 48TM500993 5.0 Packaged Rooftop Builder 1.34 Page 15 of 20 Project: -U ntitled 17 Prepared By: Certified Drawing for 3 Ton 02/13/2013 12:52PM ROZECU B ACOSS5Qt 0 A CFSECUR9:01A01 15 Psi 25 Pal n 1 N71ES 1 21SU AMPMHS25i4117M4POL SATE 7. d4OFARRUN. BCHSEE aCC4AECTORPAO(A9IECFSTNPARCOVOISR:RTMMECUMGASTYFE PAOMECREMPARVAMERR114412YEBOTICSAWECASOZMECBONS 1737.71 2175 MA 1 t4ea 547 --4-4.. F 11-93" F10319 — 1 I1 . . •9/ '1971 7017 1110321 17 i FA RERfANQi CPB/IG 93 itA14451 �1n E E ¢1 t f17E1 1i 5E1 sumo R CPENBG UM �7A I 1 1.75 —! Wisi ~ PIM 40E7 P1321 yI ` PE none CORNERDETAL COV CCI[7 iPOG &C0Ul.ECM:HOPE G49T71NG FOAERAFTG ROM OCNTROUWFNG R11N3 ACMCCOWCCNOENECE OUILETWIR SCONECIOR CR3I1.4Nfm1Mt 1H311HEOJ B 34110(N5f CR317.15.ACIID401 7/1d1114EBOf1dA 344119NP7 1?{127PP7 12112.71NPT MCTICN E -E A M.0 1131/99fl5T NSUAT®CEO6'MHS E9112¢1751WDE N31ATIMIECKPM8 7410 3.13'15 SEE VIEW 'B' ps0 Med Pe/ REVIRMECCIPD Dare BY IPD1H3 239 R11 WNG 57.7!5 (17 ) DHANEDI@HA¢1EV8. PROCUC110N grzr. COPPENSICNELPIEMILLIMEie uvm-nvawuErxa>En .1 , 1 25159 /9 1 110 •050 • 2• coallatr AUr44ed7m}P1o6pI®Carpa y 1144DODADrt,IPPNE. „1D1COPRANFOTOPETI P TWATDWA®1 104173a T.005N-002 .vwsrcn4vo Tea aRBraSYPCCF (00440 I.EC 07117/11 0E0031 SCE D aA...nr„wER 4M:0342% EEEEf 5/ 5 1�v A elw.lfwlmll rwrsam. PURC11 E1mea+reaaul>SEoan letTORAYMPI BPJLE NA asmella AlLIC Packaged Rooftop Builder 1.34 Page 16 of 20 Project:—Untitledl7 Prepared By: Performance Summary For 3 Ton 02/13/2013 12:52PM Part Number:48TCDAO4A2A6-0A0A0 ARI SEER: .. Base Unit Dimensions Unit Length:. Unit Width: Unit Height:....... Operating Weight Base Unit Weight Medium Static Option: . . . Accessories Vertical EconoMi$er IV with solid-state controller: 14 -inch Tall Roof Curb:. ..... . Total Operating Weight: Unit Unit Voltage -Phase -Hertz: Air Discharge. Fan Drive Type:....... Actual Airflow:.. . .. Site Altitude: Cooling Performance Condenser Entering Air DB:.. Evaporator Entering Air DB:. Evaporator Entering Air WB:..... Entering Air Enthalpy: ..... . Evaporator Leaving Air DB:... Evaporator Leaving Air WB:..... Evaporator Leaving Air Enthalpy: Gross Cooling Capacity:......... Gross Sensible Capacity:.... . .. Compressor Power Input:.. Coil Bypass Factor : Heating Performance Heating Airflow: Entering Air Temp:.... Leaving Air Temp:.... Gas Input Capacity:.... Gas Heating Capacity: Temperature Rise:... Supply Fan External Static Pressure: Options / Accessories Static Pressure Economizer:.. Total External Static: Fan RPM: ...... ................... ... .... Fan Power:......... NOTE:. ....... .. Electrical Data (Before July 30, 2012) Minimum Voltage:. Maximum Voltage: ........ . Compressor RLA:. Compressor LRA Outdoor Fan Motor Qty:. ........ 13.00 74.4 in 44.0 in 33.4 in 483 Ib 10 Ib 50 Ib 115 Ib 658 Ib 460-3-60 Vertical Belt 1200 CFM 0 ft 95.0 F 80.0 F 67.0 F 31.44 BTU/lb 59.7 F 57.7 F 24.84 BTU/Ib 35.65 MBH 26.25 MBH 2.48 kW 0.186 1200 CFM 70.0 F 115.5 F 72.0 MBH 59.00 MBH 45.5 F 1.00 in wg 0.04 in wg 1.04 in wg 1041 0.70 BHP Selected IFM RPM Range: 770 - 1175 414 506 5.8 38 1 Packaged Rooftop Builder 1.34 Page 17 of 20 Project:-Untitledl7 Prepared By: Performance Summary For 3 Ton 02/13/2013 12:52PM Outdoor Fan FLA (ea):........__._ Indoor Fan Motor Type:........_. _......... . Indoor Fan Motor FLA. Combustion Fan Motor FLA (ea): Power Supply MCA:._ Power Supply MOCP (Fuse or HACR): Min. Unit Disconnect FLA:_ ..... . . Min. Unit Disconnect LRA:. _.. _ .... . Electrical Convenience Outlet:..... ... . Electrical Data (July 30, 2012 and Beyond) Indoor Fan Motor FLA:. Power Supply MCA:.... Power Supply MOCP:. ... . Disconnect Size FLA:.. Disconnect Size LRA: July 30th and beyond units can be identified by serial number 3112XX10CXX)00( and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 86.4 87.2 90.6 125 Hz 79.7 77.1 80.9 250 Hz 69.9 62.7 80.2 500 Hz 66.0 61.5 76.0 1000 Hz 62.5 60.7 74.6 2000 Hz 57.3 54.5 71.3 4000 Hz 58.7 49.7 68.5 8000 Hz 53.4 42.0 63.9 A -Weighted 70.1 Advanced Acoustics 67.1 80.0 Advanced Accoustics Parameters 1. Unit height above ground- 30.0 ft 2. Horizontal distance from unit to receiver:.. 50.0 ft 3. Receiver height above ground:......... 5.7 ft 4. Height of obstruction- 0.0 ft 5. Horizontal distance from obstruction to receiver ......0.0 ft 6. Horizontal distance from unit to obstruction: 0.0 ft Detailed Acoustics Information 0.8 MED 2.1 0.24 10.2 15 10 46 None 2.6 11 15 11 49 Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k Overall Sound Power Levels at Unit's Acoustic Center (Lw), dB 90.6 80.9 80.2 76.0 74.6 71.3 68.5 63.9 91.7 Lw A -Weighted Sound Power Levels at Unit's Acoustic Center (LwA), dBA 64.4 64.8 71.6 72.8 74.6 72.5 69.5 62.8 79.9 LwA Sound Pressure Levels at Distance Specified above (Lp), dB 58.2 48.5 47.8 43.6 42.2 38.9 36.1 31.5 59.3 Lp A -Weighted Sound Pressure Levels at Distance Specified above (LpA), dBA 32.0 32.4 39.2 40.4 42.2 40.1 37.1 30.4 47.5 LpA Packaged Rooftop Builder 1.34 Page 18 of 20 Performance Summary For 3 Ton Project:—Untitledl7 Prepared By: 02/13/2013 12:52PM Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. FanCurve Airflow(CFM-thousands) RPM=1041 BHP=0.70MaxnnumRPM=1175 MaximwnHP=2.40 Note: Pleasecontactapplicationengineeringforselectionsoutsidetheshadediegion. SC-SystemQxrve RP-RatedPoint Packaged Rooftop Builder 1.34 Page 19 of 20 •e`•••�i ::f nrif ff.�. Project:-Untitled17 Prepared By: Unit Feature Sheet for 3 Ton 02/13/2013 12:52PM WeatherMaker — 48TC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 3, 4, 5, 6, 7.5, 8.5, 10, 12,5, 15 TON S Optional Louvered Hail Guard Shown WEATHERMAKER SERIES WeatherMaker(48TC) units are one-piece gas heating. electric cooling units that are pre -wired and charged with Puron (R-410) refrigerant. They are factorytested in both heating and cooling modes, and rated in accordance with AHRI Standards 2101240(04-06 sizes) and 340/360 (07-16 sizes). WeatherMaker units are designed in accordance with UL Standard 1995, and listed by the Underwriters' Laboratories. Approved and certified by: US Certified to ISO 9001 STANDARD FEATURES INCLUDE: • Puron (R-413A)f;FC refrraarent • ASMRAE83.1 energycomoiiant • Scra' wmp'sasors :win interns: lint brisk end ave•as•d prote:ton • Sang''a-semi•aecooling C9oicitycontra fon04.12r?VD des • r D3t•aecDDhngc9D9cty'Ca 1 en9S•16model • SEER'S uo to 13.0, EER's up to 11.1 and IEERs up to 11.5 • Acutrorr"refr"tgerent ieteringsystem • ExcIus.•ve noncorosio't conpostecondensate pen In Dotards nee'wIth ASI -RAE Standard 62, voping deign. sae or vanterdrsin • Standard coo+.ng op eation up to 115'F (45'4:and down to 43'F ,4'G;. • down to 25' F ,-4' voth winter sten krt. • Pre-osInled *Mena rpinta and pnrae• costed interior oaneis tested to 533 bows salt spray prrtetion • FuIiyinsu:atedcsD,1.1 • ExclusiveIG: soid-st9tecontra faron•bperidtan Dsticswith LED errprcodedes.anstionbunerrntro'.logo and ene•gysevn9 indoo• fen motor deify • Low ItiOx mode's that mut Cp>fami4 A:• ausi:ty M9n•genent • Induoeddraftgasheat corrrbustandesan • Redund•ntget vai.eswan up to two stages of heitng • Lp'a•p:essure end nign pressure swan protected. MAINTENANCE FEATURES: • ACcesstenet wrtn easygrip bandies • Innovative easy starting. no•strp screws an un It sixes; panes • Tw•o-ihchdIsoossa!ereturn sir fiat rsand Tooi-nessMar amssdoor • eetdrveevsporetor--fen motor and pulpy combinations • Newterninsl board fscilit•tina simple safetycircuit troubleshooting mind s!mp;f;ed control box arengernent • ExousveIGC soid•statecontra! for on -board dsanostiswith LEC errarcode designetan. burnercontrp'. iogki. end energy saving indoor fan motordel•y. IN STALLATION FEATURES: • Th rd the-botWmpo»ere ntri cepa bii1y • Single point gas andeectri:connections • Ful perimeter bast rail w•.th but -in rygrig adopters and fork sots • Fed convertib*fram-vetics::toho!tontaisirfrow•fprsal bmounting. (15ize mode isrGSluire Mid installed au pply'duct C3o'e j. STANDARD WARRANTY: • 10 -yes• nest etch enger- 15-ye•rits Inless gee' option • 5-yesrc rnpressar • 1 -year parts • 3 -year parts on tiovtan CondensercoiS-where avaisbe • Manyoptiono' Jog roles e=averebe OPTIONS INCLUDE BUT ARE NOT LIMITED TO: • PremerLmk^' and RTU' Open Muni Protocol CCC Controls • Supply and Return Air Smoke Detectors. high stat: motors • Lou'ventdcondensergaguards • Eoonom¢er,disconnect and conventenoeoutetoptions • Stainiess Steel he at exchange rowan • Corrosion resistant co; costing. • M4m;di-M2efadaptve de humi9dcafionsystem availsb4onell mo•deswith RTPF condsnserco- Motor Master Icontrarier included • fringed areas pant Is Fara compete irrt of Dp0015 9r d secessona4 NOV to the Product Cats :•atsiog forth s unit Packaged Rooftop Builder 1.34 Page 20 of 20 . Table 2 - AHRI COOLING RATING TABLE UNIT COOLING STAGES NOM. CAPACITY (TONS) NET COOLING CAPACITY (MBH) TOTAL POWER (KW) SEER EER IEER A04 1 3 34.6 3.1 13.0 11.00 N/A A05 1 4 45.0 4.0 13.0 11.00 N/A A06 1 5 59.0 5.5 13.0 10.75 N/A A07 1 6 70.0 6.4 N/A 11.00 11.2 A08 1 7.5 88.0 8.0 N/A 11.00 11.2 A09 1 8.5 97.0 8.8 N/A 11.00 11.2 Al2 1 10 117.0 10.6 N/A 11.00 11.2 UNIT COOLING STAGES NOM. CAPACITY (TONS) NET COOLING CAPACITY (MBH) TOTAL POWER ( EER IEER WITH SINGLE SPEED INDOOR FAN MOTOR IEER WITH 2 SPEED INDOOR FAN MOTOR D08 2 7.5 83.0 7.5 11.00 11.7 12.8 D09 2 8.5 97.0 9.0 11.00 11.2 12.8 D12 2 10 114.0 10.3 11.10 11.8 12.8 D14 2 12.5 140.0 12.9 10.80 11.0 11.8 D16 2 15 174.0 16.1 10.80 11.7 12.4 LEGEND AHRI - Air Conditioning, Heating and Refrigeration Institute Test Standard ASHRAE - American Society of Heating, Refrigerating and Air Conditioning, Inc. EER - Energy Efficiency Ratio IEER - Integrated Energy Efficiency Ratio N/A - Not Applicable SEER - Seasonal Energy Efficiency Ratio Us 1w1 COMP LIANT .;a " i CERTIFIED. Use of the AHRI Certified TM Mark indicates a manufacturers participation in the program For verification of certification for individual products. go to www.artridirectmµorp. NOTES: 1. Rated in accordance with AHRI Standard 210/240 or 340/360, as appropriate. 2. Ratings are based on: Cooling Standard: 80°F (27°C) db, 67°F (19°C) wb indoor air temp and 95°F (35°C) db outdoor air temp. IEER Standard: A measure that expresses cooling part - load EER efficiency for commercial unitary air conditioning and heat pump equipment on the basis of weighted opera- tion at various Toad capacities. 3. All 48TC units comply with ASHRAE 90.1 Energy Standard for minimum SEER and EER requirements. 4. 48TC units comply with US Energy Policy Act (2005). To eval- uate code compliance requirements, refer to state and local codes. 9 Load Express: Load Calculation Software Version 2.2 Title Page Load Express: Load Calculation Software By: Seattle Mechanical General Job Job Description: Building Owner: Program User: Comments: Fuse Networks Seattle Mechanical Program was Run: 2/27/20133t 1:15:51 PM Dataset Name: C:\CDS\LOADEXP\DATA\FUSE.LE No rite CODy Alternative 1 AIt1 Geographical Data Location: Weather File: Latitude: Elevation: Seattle, Washington Seattle, Washington 47 deg 386 ft Design Data Summer Dsn Dry Bult Summer Dsn Wet Bul Winter Design Dry Bu Density -Sp Heat Prod Design Simulation per REVIEWED FOR CODE COMPLIANCE APPROVED MAR 13 2013 City of Tukwila BUILDING DIVISION 80.0 deg F 64.0 deg F 26.0 deg F 1.0988 Btu-min/(hr-ft3-F) Apr To Nov Building Peak Data Month/Hour: Jul / 14 Cooling Capacity: 140.8 Mbh Cooling Sensible: 108.6 Mbh Sensible Heat Ratio (SH 0.848 Heating Capacity -119.1 Mbh RECEIVED CITY OF TUKWILA MAR 0 5 2013 PERMIT CENTER MIU5 Loaa txpress: Loaa Lamination Jonware version 2.2 Zone/Air Handler Descriptions Zone/Air Handler Descriptions Alternative - 1 Alt1 Air Handler Type Description 1 CONSTANT AHU2 2 CONSTANT AHU3 3 CONSTANT AHU1 Zone Type Description 1 Commercial Retail Zone1 2 Commercial Retail Zone2 3 Commercial Retail Zone3 Load Express: Load Calculation Software Alternative 1 Alt1 1-2 Story Office Version 2.2 Zone Input Data General Job Data Weather Location: Seattle, Washington Weather Region: Northwest Clg Simulation Start Month: Apr Clg Simulation End Month: Nov Zone Data Alternative Number: 1 Zone Number: 1 Floor Width: 28 ft Floor Length: 74 ft Ceiling Height: 10 ft Fir -to -Fir Height: 16 ft No. of Dup Zones: 1 Ceiling U -Factor: 0.04 Btu/(hr-F-ft2) Floor Calculation Type: Slab -On -Grade Floor Loss Coefficient: 0.73 Btu/(hr-F-ft) Floor Perimeter Length130.00 ft W H Type ft ft Building Opening Time: 8 am Building Closing Time: 6 pm Building Direction: 0 Clg Sensible SF: 10.00 Cooling Dry Bulb: Relative Humidity: Heating Dry Bulb: People Density: People Activity: People Sensible Load: People Latent Load: Misc. Equip. Type: Misc. Equip. Sensible Load Misc. Equip. Latent Load: Misc. Equip. Sensible to R. Lighting Intensity: Lighting Type: .ecessed fluorescent, not vented 74 deg F 50 % 70 deg F 100 ft2/pers General Office Space 210 Btuh/pers 255 Btuh/pers Microcomputers 350.00 Watt/pers 0.00 W att/ft2 0 Btuh 0.91 W att/ft2 Clg Latent SF: 10 Htg Sensible SF: 10 People Diversity: 100 % Bldg Simulation Type: Cooling and Heating Ballast Factor: 1.00 % Percent Light to RA: 50 % Vent Type: General Office Space Vent Cool Design: 20.00 cfm/pers Vent Heat Design: 20.00 cfm/pers Supply Cool Design: 0 cfm Supply Heat Design: 0 cfm Infiltration Type: Pressurized, Average Construction Infilt. Cooling Desigi 0.30 ach/hr Infilt. Heating Desigi 0.30 ach/hr Room Exhaust: 0.00 cfm U -Factor Color Percent (%) Direction Susp Ceil Tilt Cool Adj Heat Adj Dimension °A, Glass Shading Coeff Shading Spc Temp Spc Temp degF deg F WALL ROOF PART PART 1 30 x 9 8" L.W. Concrete Blk, 6" Ins 1 28 x 74 4" Wood deck, 6" Ins, SusClg 1 28 x 9 Frame, 0.75" gypsum board 2 74 x 7 Frame, 0.75" gypsum board 0.04 Light West 0.04 Light 0 RA North Yes 0.39 0.39 0 0 0 0 0 80 0 80 0 0 45 45 0.00 0.00 0.00 0.00 Load Express: Load Calculation Software Zone Data Alternative Number: 1 Zone Number: 2 Floor Width: 24 ft Floor Length: 56 ft Ceiling Height: 9 ft Fir -to -Fir Height: 16 ft No. of Dup Zones: 1 Ceiling U -Factor: 0.04 Btu/(hr-F-ft2) Floor Calculation Type: None W H Type Cooling Dry Bulb: Relative Humidity: Heating Dry Bulb: People Density: People Activity: People Sensible Load: People Latent Load: Misc. Equip. Type: Misc. Equip. Sensible Load Misc. Equip. Latent Load: Misc. Equip. Sensible to RI Lighting Intensity: Lighting Type: .ecessed 72 deg F 50 % 70 deg F 100 ft2/pers General Office Space 210 Btuh/pers 255 Btuh/pers Microcomputers 350.00 0.00 0 0.91 Watt/pers W att/ft2 Btuh Watt/ft2 fluorescent, not vented Version 2.2 Zone Input Data Ballast Factor: 1.00 % Percent Light to RA: 50 oh. Vent Type: General Office Space Vent Cool Design: 20.00 cfm/pers Vent Heat Design: 20.00 cfm/pers Supply Cool Design: 0 cfm Supply Heat Design: 0 cfm Infiltration Type: Pressurized, Average Construction Infilt. Cooling Desigi 0.30 ach/hr Infilt. Heating Desigi 0.30 ach/hr Room Exhaust: 160.00 cfm U -Factor Color Percent (%) Direction Susp Cell Tilt Cool Adj Heat Adj Dimension % Glass Shading Coeff Spc Temp Spc Temp degF deg F Shading ROOF 1 24 x 56 4" Wood deck, 6" Ins, SusClg PART 1 56 x 9 Frame, 0.75" gypsum board 0.04 Light 0 RA North 0.39 Yes 0 0 0 0.00 0 72 70 0.00 Load Express: Load Calculation Software Zone Data Alternative Number: 1 Zone Number: 3 Floor Width: 18 ft Floor Length: 90 ft Ceiling Height: 9 ft Flr-to-Flr Height: 16 ft No. of Dup Zones: 1 Ceiling U -Factor: 0.04 Btu/(hr-F-ft2) Floor Calculation Type: Slab -On -Grade Floor Loss Coefficient: 0.73 Btu/(hr-F-ft) Floor Perimeter Length135.00 ft W H Type ft ft Cooling Dry Bulb: Relative Humidity: Heating Dry Bulb: People Density: People Activity: People Sensible Load: People Latent Load: Misc. Equip. Type: Misc. Equip. Sensible Load Misc. Equip. Latent Load: Misc. Equip. Sensible to RV Lighting Intensity: Lighting Type: ecessed fluorescent, not vented 72 deg F 50 % 70 deg F 100 ft2/pers General Office Space 210 Btuh/pers 255 Btuh/pers Microcomputers 350.00 Watt/pers 0.00 Watt/ft2 0 Btuh 0.91 W att/ft2 Version 2.2 Zone Input Data Ballast Factor: 1.00 % Percent Light to RA: 50 % Vent Type: General Office Space Vent Cool Design: 20.00 cfm/pers Vent Heat Design: 20.00 cfm/pers Supply Cool Design: 0 cfm Supply Heat Design: 0 cfm Infiltration Type: Pressurized, Average Construction Infilt. Cooling Desigi 0.30 ach/hr Infilt. Heating Desigi 0.30 ach/hr Room Exhaust: 0.00 cfm U -Factor Color Percent (%) Direction Susp Ceil Tilt Cool Adj Heat Adj Dimension % Glass Shading Coeff Spc Temp Spc Temp degF deg F Shading WALL 1 GLASS 1 ROOF 1 PART 1 135 x 9 8" L.W. Concrete Blk, 6" Ins 66 x 7 Double Coated 1/4 in. 18 x 90 4" H.W. Dk., 6" Ins 88 x 9 Frame, 0.75" gypsum board 0.04 Light North 0.50 0 Plenum 0.05 Light 0 RA North Yes 0.39 0 0 0 0 0 0 0 72 0 0 Area 0 70 0.00 0.55 External 0.00 0.00 Air Handler Input Air Handler Input Alternative 1 Air Handler 1 Fan Configuration: Draw Fan & Motor Efficiency: 56.00 % Cooling Supply Air Temp: 55.00 deg F Heating Supply Air Temp: 0.00 deg F Minimum Relative Humidity: 40 % Supply Fan Static Pressure: 2.00 in H2O Return Fan Static Pressure: 0.00 in H2O CONSTANT AHU2 Supply Duct Location: Supply Duct Insulation: Supply Duct Temp Rise: Return Duct Insulation: Return Duct Temp Rise: Terminal Type: Total Cool Airflow: Total Heat Airflow: Zone(s) Connected: Unvented Space R4 Duct Insulation 0.5 degFTD R4 Duct Insulation 0.3 degFTD CONSTANT 0 cfm 0 cfm 1 Air Handler 2 Fan Configuration: Draw Fan & Motor Efficiency: 56.00 % Cooling Supply Air Temp: 55.00 deg F Heating Supply Air Temp: 0.00 deg F Minimum Relative Humidity: 0 % Supply Fan Static Pressure: 2.00 in H2O Return Fan Static Pressure: 0.00 in H2O CONSTANT AHU3 Supply Duct Location: Supply Duct Insulation: Supply Duct Temp Rise: Return Duct Insulation: Return Duct Temp Rise: Terminal Type: Total Cool Airflow: Total Heat Airflow: Zone(s) Connected: Unvented Space R4 Duct Insulation 0.5 deg F TD R4 Duct Insulation 0.3 deg F TD CONSTANT 0 0 2 cfm cfm Air Handler 3 Fan Configuration: Draw Fan & Motor Efficiency: 56.00 % Cooling Supply Air Temp: 55.00 deg F Heating Supply Air Temp: 0.00 deg F Minimum Relative Humidity: 0 % Supply Fan Static Pressure: 2.00 in H2O Return Fan Static Pressure: 0.00 in H2O CONSTANT AHU1 Supply Duct Location: Supply Duct Insulation: Supply Duct Temp Rise: Return Duct Insulation: Return Duct Temp Rise: Terminal Type: Total Cool Airflow: Total Heat Airflow: Zone(s) Connected: Unvented Space R4 Duct Insulation 0.5 degFTD R4 Duct Insulation 0.3 degFTD CONSTANT 0 0 3 cfm cfm Load Express: Load Calculation Software versio2.2 Peak Load Information Altemative 1 Design Heating: Airflow (cfm) Space Total Heating Coil Total Outside % O.A. Sensible Sensible Entering Leaving Humidification Air Handler fl/Type Btuh Btuh DB DB Btuh BLDG BLOCK -53,278.30 -119,078.00 -11,121.5 BLDG PEAK -53,278.30 -119,078.00 -11,121.5 1 CONSTANT 1,729.88 414.40 23.96 -22,335.30 -56,607.90 58.41 81.75 -11,121.5 2 CONSTANT 1,199.37 268.80 22.41 -5,493.24 -19,788.80 59.15 74.17 3 CONSTANT 2,021.06 324.00 16.03 -25,449.80 -42,681.00 62.24 81.46 Design Cooling: Airflow (cfm) Cooling Cooling Coil Total Outside %O.A Total Sensible S.H.R. Entering Leaving ft2/ton cfm/ton cfrn/ft2 Total Air Handler ft/Type Btuh Btuh DB WB DB WB tons BLDG BLOCK 140,793.00 119,461.00 0.85 429.23 11.7 BLDG PEAK 140,793.00 119,461.00 0.85 429.23 11.7 1 CONSTANT 1,729.88 414.40 23.96 52,641.80 44,064.10 0.84 76.84 62.11 53.20 51.42 472.33 394.3 0.8 4.4 2 CONSTANT 1,199.37 268.80 22.41 34,329.90 28,723.60 0.84 75.40 61.54 53.20 51.42 469.80 419.2 0.9 2.9 3 CONSTANT 2,021.06 324.00 16.03 53,821.30 46,672.90 0.87 74.41 60.84 53.20 51.42 361.20 450.6 1.2 4.5 Building Peak Load Components Cooling (Btuh) Heating (Btuh) Mo/Hr: Solar Cond Internal OA+Inf Misc Total Cond OA+Inf Misc Total Bldg 7/14 7,826.8 3,617.1 92,704.2 15,529.6 8,315.9 127,994.0 -36,977.3 -60,153.8 -11,121.9 -108,253.0 Air Hand 1 7/14 1,860.4 37,872.5 5,587.9 2,535.4 47,856.1 -15,295.9 -25,044.3 -11,121.5 -51,461.7 Zone 1 7/14 1,860.4 37,872.5 5,587.9 2,535.4 47,856.1 -15,295.9 -25,044.3 -11,121.5 -51,461.7 Air Hand 2 7/14 138.8 24,597.2 4,346.9 2,126.1 31,209.0 -2,069.8 -15,920.1 0.1 -17,989.8 Zone 2 7/14 138.8 24,597.2 4,346.9 2,126.1 31,209.0 -2,069.8 -15,920.1 0.1 -17,989.8 Air Hand 3 7/14 7,826.8 1,617.9 30,234.5 5,594.8 3,654.5 48,928.5 -19,611.6 -19,189.4 0.1 -38,800.9 Zone 3 7/14 7,826.8 1,617.9 30,234.5 5,594.8 3,654.5 48,928.5 -19,611.6 -19,189.4 0.1 -38,800.9 Loa° txpress: Loa° t;aicuIation sonware Psychrometric State Points - Alternative 1 AIt1 Zone 1 Dry Bulb Wet Bulb Temp Diff. Zone1 ( deg F ) ( deg F ) ( deg F ) Space 74.0 60.7 Zone Return Air Heat Pickup Retum Fan Return Air 75.9 61.4 Outdoor Air 79.4 64.3 Retum/Outdoor Air Mix 76.8 62.1 Blow Through Fan Entering Coil 76.8 62.1 Leaving Coil 53.2 51.4 Draw Through Fan Supply Duct Heat Gain Supply Air 55.0 52.2 Percent Outside Air 26.35 % Space Sensible Heat Ratio (SHR) 0.869 Coil Airflow 1,573 cfm 1.9 0.0 0.0 1.3 0.5 Zone 2 Dry Bulb Wet Bulb Temp Diff. Zone2 ( deg F ) ( deg F ) ( deg F ) Space 72.0 59.9 Zone Retum Air Heat Pickup Retum Fan Return Air 74.1 60.7 Outdoor Air 79.4 64.3 Retum/Outdoor Air Mix 75.4 61.5 Blow Through Fan Entering Coil 75.4 61.5 Leaving Coil 53.2 51.4 Draw Through Fan Supply Duct Heat Gain Supply Air 55.0 52.2 Percent Outside Air Space Sensible Heat Ratio (SHR) Coil Airflow 24.65 % 0.864 1,090 cfm 2.1 0.0 0.0 1.3 0.5 version z.z Psychrometrics Loaa txpress: Loaa L,aicuiauon aonware Psychrometric State Points - Alternative 1 AIt1 Zone 3 Dry Bulb Wet Bulb Temp Diff. Zone3 ( deg F ) ( deg F ) ( deg F ) Space 72.0 59.6 Zone Return Air Heat Pickup 1.3 Retum Fan 0.0 Return Air 73.3 60.1 Outdoor Air 79.4 64.3 Return/Outdoor Air Mix 74.4 60.8 Blow Through Fan 0.0 Entering Coil 74.4 60.8 Leaving Coil 53.2 51.4 Draw Through Fan 1.3 Supply Duct Heat Gain 0.5 Supply Air 55.0 52.2 Percent Outside Air Space Sensible Heat Ratio (SHR) Coil Airflow 17.63 % 0.897 1,837 cfm V CI L.L Psychrometrics Load Express: Load Calculation Software Version 2.2 Sensible Load Profile . Sensible Load Profile (Mbh)- Alternative 1 AM Hour 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Air Hand 1 2 1 0 0 0 0 0 28 30 33 35 37 39 40 41 41 40 39 11 8 6 5 3 3 Air Hand 2 1 1 0 0 0 0 0 18 20 21 23 24 25 26 27 27 26 26 7 5 4 3 2 2 Air Hand 3 2 1 0 0 0 0 2 25 30 33 36 39 41 42 43 43 42 40 16 10 8 6 4 3 Bldg 5 2 0 0 -1 0 1 71 80 87 94 101 105 109 110 110 108 105 34 24 18 13 10 7 Zone 1 2 1 0 0 0 0 0 28 30 33 35 37 39 40 41 41 40 39 11 8 6 5 3 3 Zone 2 1 1 0 0 0 0 0 18 20 21 23 24 25' 26 27 27 26 26 7 5 4 3 2 2 Zone 3 2 1 0 0 0 0 2 25 30 33 36 39 41 42 43 43 42 40 16 10 8 6 4 3 Loaa txpress Load uaicuiation sonware version z.z Peak Load Summary Peak Load Summary - Alternative 1 Air Hand 1 AHU2 Areas ( ft2 ) Floor: 2,072.0 SlabOnG/ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 130.0 2,072.0 0.0 270.0 0.0 770.0 AIt1 Space Sens Load Spc Sens Ld W/Sfty Fctr Cool Airflow Cool Airflw W/Sfty Fctor Cooling Check Cool Check W/Sfty Fctr Heat Airflow Heat Airflw W/Sfty Fctr 32,832.5 Btuh 36,115.8 Btuh 1,573 cfm 1,730 cfm 0.76 cfm/ft2 0.83 cfm/ft2 1,573 cfm 1,730 cfm Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo/Hr: 7 / 14 Outside Air: OADB: 79 WB: 64 RELHUM: 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) (%) ( Btuh) (%) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 0.00 0.00 0.00 Sub Total 0.00 0.00 0.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 71.75 71.75 -3,190.88 Glass 0.00 0.00 0.00 Wall 5.32 5.32 -498.96 Partition 1,783.32 1,783.32 -7,430.50 SlabOnG/ExFlr 0.00 0.00 -4,175.60 Sub Total 1,860.39 1,860.39 3.89 -15,295.90 29.72 INTERNAL LOADS Lights 5,708.19 5,708.19 0.00 People 9,302.64 4,019.04 0.00 Misc 22,861.70 22,861.70 0.00 Sub Total 37,872.50 32,588.90 79.14 0.00 0.00 MISC LOADS Outside Air 4,470.29 2,458.90 -20,035.50 Humidification 0.00 0.00 -11,121.50 Infiltration 1,117.57 614.73 -5,008.87 Sup. Fan Heat 2,246.60 2,246.60 0.00 Ret. Fan Heat 0.00 0.00 0.00 Duct Heat Pkup 1,382.42 1,382.42 0.00 Exhaust Heat -1,093.62 -1,093.62 0.00 Sub Total 8,123.27 5,609.02 16.97 -36,165.80 70.28 OV/UNDR Sizing 0.00 0.00 0.00 Grand Total 47,856.10 40,058.30 -51,461.70 W/Safety Factor 52,641.80 44,064.10 -56,607.90 Loaa xpress: Loaa c;aicuiation 5onware Version 2.2 Peak Load Summary Peak Load Summary - Alternative 1 Air Hand 2 AHU3 Areas ( ft2 ) Floor: SlabOnG/ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 1,344.0 0.0 1,344.0 0.0 0.0 0.0 504.0 Alt1 Space Sens Load Spc Sens Ld W/Sfty Fctr Cool Airflow Cool Airflw W/Sfty Fctor Cooling Check Cool Check W/Sfty Fctr Heat Airflow Heat Airflw W/Sfty Fctr 20,367.4 Btuh 22,404.1 Btuh 1,090 cfm 1,199 cfm 0.81 cfm/ft2 0.89 cfm/ft2 1,090 cfm 1,199 cfm Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo/Hr: 7 / 14 Outside Air: OADB: 79 WB: 64 RELHUM: 44.2% Cooling Coil Peak Heating Coil Peak Total Load ( Btuh) Sens Load Percnt of Tot ( Btuh ) (%) Peak Tot Sens ( Btuh) Percnt of Tot (%) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 0.00 0.00 0.00 Sub Total 0.00 0.00 0.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 138.80 138.80 -2,069.76 Glass 0.00 0.00 0.00 Wall 0.00 0.00 0.00 Partition 0.00 0.00 0.00 SlabOnG/ExFIr 0.00 0.00 0.00 Sub Total 138.80 138.80 0.44 -2,069.76 11.51 INTERNAL LOADS Lights 3,733.88 3,733.88 0.00 People 6,034.15 2,606.95 0.00 Misc 14,829.20 14,829.20 0.00 Sub Total 24,597.20 21,170.00 78.81 0.00 0.00 MISC LOADS Outside Air 3,548.52 2,185.69 -12,996.00 Humidification 0.00 0.00 0.00 Infiltration 798.42 491.78 -2,924.09 Sup. Fan Heat 1,557.62 1,557.62 0.00 Ret. Fan Heat 0.00 0.00 0.00 Duct Heat Pkup 958.46 958.46 0.00 Exhaust Heat -390.03 -390.03 0.00 Sub Total 6,472.99 4,803.52 20.74 -15,920.10 88.50 OV/UNDR Sizing 0.00 0.00 0.00 Grand Total 31,209.00 26,112.30 -17,989.80 W/Safety Factor 34,329.90 28,723.60 -19,788.80 LULU C74JI ebb . LVdU L,dIUUIdLIVII JUILVVcilr. vciawn c.c Peak Load Summary Peak Load Summary - Alternative 1 AIt1 Air Hand 3 AHU1 Areas ( ft2 ) Space Sens Load 34,321.3 Btuh Heating Coil Peak Floor: 1,620.0 Spc Sens Ld W/Sfty Fctr 37,753.4 Btuh Outside Air: OADB: 26 SlabOnG/ExFIr: 135.0 Cool Airflow 1,837 cfm Roof: 1,620.0 Cool Airflw W/Sfty Fctor 2,021 cfm Cooling Coil Peak Skylight: 0.0 Cooling Check 1.13 cfm/ft2 Peaked at Time: Mo/Hr: 7 / 14 Wall: 753.0 Cool Check W/Sfty Fctr 1.25 cfm/ft2 Outside Air: OADB: 79 Wall Glass: 462.0 Heat Airflow 1,837 cfm WB: 64 Partition: 792.0 Heat Airflw W/Sfty Fctr 2,021 cfm RELHUM: 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) (%) ( Btuh) (%) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 7,826.76 7,826.76 0.00 Sub Total 7,826.76 7,826.76 16.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 40.42 40.42 -3,278.88 Glass 1,638.48 1,638.48 -10,604.90 Wall -60.99 -60.99 -1,391.54 Partition 0.00 0.00 0.00 SlabOnG/ExFIr 0.00 0.00 -4,336.20 Sub Total 1,617.90 1,617.90 3.31 -19,611.60 50.54 INTERNAL LOADS Lights 4,343.71 4,343.71 0.00 People 7,384.40 3,253.40 0.00 Misc 18,506.40 18,506.40 0.00 Sub Total 30,234.50 26,103.50 61.79 0.00 0.00 MISC LOADS Outside Air 4,567.22 2,634.53 -15,664.80 Humidification 0.00 0.00 0.00 Infiltration 1,027.62 592.77 -3,524.58 Sup. Fan Heat 2,624.76 2,624.76 0.00 Ret. Fan Heat 0.00 0.00 0.00 Duct Heat Pkup 1,615.12 1,615.12 0.00 Exhaust Heat -585.43 -585.43 0.00 Sub Total 9,249.29 6,881.75 18.90 -19,189.40 49.46 OV/UNDR Sizing 0.00 0.00 0.00 Grand Total 48,928.50 42,429.90 -38,800.90 W/Safety Factor 53,821.30 46,672.90 -42,681.00 Peak Load Summary Peak Load Summary - Alternative 1 AIt1 Bldg 1 Areas ( ft2 ) Floor: 5,036.0 SlabOnG/ExFlr: 265.0 Roof: 5,036.0 Skylight: 0.0 Wall: 1,023.0 Wall Glass: 462.0 Partition: 2,066.0 Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo/Hr: 7 / 14 Outside Air: OADB: 79 WB: 64 RELHUM: 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) (%) ( Btuh) (%) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 7,826.76 7,826.76 0.00 Sub Total 7,826.76 7,826.76 6.11 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 250.97 250.97 -8,539.52 Glass 1,638.48 1,638.48 -10,604.90 Wall -55.67 -55.67 -1,890.50 Partition 1,783.32 1,783.32 -7,430.50 SlabOnG/ExFIr 0.00 0.00 -8,511.80 Sub Total 3,617.09 3,617.09 2.83 -36,977.30 34.16 INTERNAL LOADS Lights 13,785.80 13,785.80 0.00 People 22,721.20 9,879.39 0.00 Misc 56,197.30 56,197.30 0.00 Sub Total 92,704.20 79,862.40 72.43 0.00 0.00 MISC LOADS Outside Air 12,586.00 7,279.12 -48,696.20 Humidification 0.00 0.00 -11,121.50 Infiltration 2,943.61 1,699.27 -11,457.50 Sup. Fan Heat 6,428.98 6,428.98 0.00 Ret. Fan Heat 0.00 0.00 0.00 Duct Heat Pkup 3,956.00 3,956.00 0.00 Exhaust Heat -2,069.08 -2,069.08 0.00 Sub Total 23,845.50 17,294.30 18.63 -71,275.20 65.84 OV/UNDR Sizing 0.00 0.00 0.00 Grand Total 127,994.00 108,601.00 -108,253.00 W/Safety Factor 140,793.00 119,461.00 -119,078.00 Peak Load Summary Peak Load Summary - Alternative 1 Zone 1 Zone1 Areas ( ft2 ) Floor: 2,072.0 SlabOnG/ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 130.0 2,072.0 0.0 270.0 0.0 770.0 AIt1 Space Sens Load Spc Sens Ld W/Sfty Fctr Cool Airflow Cool Airflw W/Sfty Fctor Cooling Check Cool Check W/Sfty Fctr Heat Airflow Heat Airflw W/Sfty Fctr 32,832.5 36,115.8 1,573 1,730 0.76 0.83 1,573 1,730 Btuh Btuh cfm cfm cfm/ft2 cfm/ft2 cfm cfm Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo/Hr: Outside Air: OADB: WB: RELHUM: 7 / 14 79 64 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) (%) ( Btuh) (%) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 0.00 0.00 0.00 Sub Total 0.00 0.00 0.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 71.75 71.75 -3,190.88 Glass 0.00 0.00 0.00 Wall 5.32 5.32 -498.96 Partition 1,783.32 1,783.32 -7,430.50 SlabOnG/ExFlr 0.00 0.00 -4,175.60 Sub Total 1,860.39 1,860.39 3.89 -15,295.90 29.72 INTERNAL LOADS Lights 5,708.19 5,708.19 0.00 People 9,302.64 4,019.04 0.00 Misc 22,861.70 22,861.70 0.00 Sub Total 37,872.50 32,588.90 79.14 0.00 0.00 MISC LOADS Outside Air 4,470.29 2,458.90 -20,035.50 Humidification 0.00 0.00 -11,121.50 Infiltration 1,117.57 614.73 -5,008.87 Sup. Fan Heat 2,246.60 2,246.60 0.00 Ret. Fan Heat 0.00 0.00 0.00 Duct Heat Pkup 1,382.42 1,382.42 0.00 Exhaust Heat -1,093.62 -1,093.62 0.00 Sub Total 8,123.27 5,609.02 16.97 -36,165.80 70.28 OV/UNDR Sizing 0.00 0.00 0.00 Grand Total 47,856.10 40,058.30 -51,461.70 W/Safety Factor 52,641.80 44,064.10 -56,607.90 7 / 14 79 64 44.2% Peak Load Summary Peak Load Summary - Alternative 1 AIt1 Zone 2 Zone2 Areas ( ft2 ) Floor: SlabOnG/ExFIr: Roof: Skylight: Wall: Wall Glass: Partition: 1,344.0 0.0 1,344.0 0.0 0.0 0.0 504.0 Space Sens Load Spc Sens Ld W/Sfty Fctr Cool Airflow Cool Airflw W/Sfty Fctor Cooling Check Cool Check W/Sfty Fctr Heat Airflow Heat Airflw W/Sfty Fctr 20,367.4 22,404.1 1,090 1,199 0.81 0.89 1,090 1,199 Btuh Btuh cfm cfm cfm/ft2 cfm/ft2 cfm cfm Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo/Hr: 7 / 14 Outside Air: OADB: 79 WB: 64 RELHUM: 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) (%) ( Btuh) (%) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 0.00 0.00 0.00 Sub Total 0.00 0.00 0.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 138.80 138.80 -2,069.76 Glass 0.00 0.00 0.00 Wall 0.00 0.00 0.00 Partition 0.00 0.00 0.00 SlabOnG/ExFIr 0.00 0.00 0.00 Sub Total 138.80 138.80 0.44 -2,069.76 11.51 INTERNAL LOADS Lights 3,733.88 3,733.88 0.00 People 6,034.15 2,606.95 0.00 Misc 14,829.20 14,829.20 0.00 Sub Total 24,597.20 21,170.00 78.81 0.00 0.00 MISC LOADS Outside Air 3,548.52 2,185.69 -12,996.00 Humidification 0.00 0.00 0.00 Infiltration 798.42 491.78 -2,924.09 Sup. Fan Heat 1,557.62 1,557.62 0.00 Ret. Fan Heat 0.00 0.00 0.00 Duct Heat Pkup 958.46 958.46 0.00 Exhaust Heat -390.03 -390.03 0.00 Sub Total 6,472.99 4,803.52 20.74 -15,920.10 88.50 OV/UNDR Sizing 0.00 0.00 0.00 Grand Total 31,209.00 26,112.30 -17,989.80 W/Safety Factor 34,329.90 28,723.60 -19,788.80 Peak Load Summary Peak Load Summary - Alternative 1 AIt1 Zone 3 Zone3 Areas ( ft2 ) Floor: 1,620.0 SlabOnG/ExFlr: 135.0 Roof: 1,620.0 Skylight: 0.0 Wall: 753.0 Wall Glass: 462.0 Partition: 792.0 Space Sens Load Spc Sens Ld W/Sfty Fctr Cool Airflow Cool Airflw W/Sfty Fctor Cooling Check Cool Check W/Sfty Fctr Heat Airflow Heat Airflw W/Sfty Fctr 34,321.3 37,753.4 1,837 2,021 1.13 1.25 1,837 2,021 Btuh Btuh cfm cfm cfm/ft2 cfm/ft2 cfm cfm Heating Coil Peak Outside Air: OADB: 26 Cooling Coil Peak Peaked at Time: Mo/Hr: Outside Air: OADB: WB: RELHUM: 7 / 14 79 64 44.2% Cooling Coil Peak Heating Coil Peak Total Load Sens Load Percnt of Tot Peak Tot Sens Percnt of Tot ( Btuh) ( Btuh ) (%) ( Btuh) (%) ENVELOPE LOADS Solar Skylight Solar 0.00 0.00 0.00 Glass Solar 7,826.76 7,826.76 0.00 Sub Total 7,826.76 7,826.76 16.00 0.00 0.00 Conducted Skylight 0.00 0.00 0.00 Roof 40.42 40.42 -3,278.88 Glass 1,638.48 1,638.48 -10,604.90 Wall -60.99 -60.99 -1,391.54 Partition 0.00 0.00 0.00 SlabOnG/ExFlr 0.00 0.00 -4,336.20 Sub Total 1,617.90 1,617.90 3.31 -19,611.60 50.54 INTERNAL LOADS Lights 4,343.71 4,343.71 0.00 People 7,384.40 3,253.40 0.00 Misc 18,506.40 18,506.40 0.00 Sub Total 30,234.50 26,103.50 61.79 0.00 0.00 MISC LOADS Outside Air 4,567.22 2,634.53 -15,664.80 Humidification 0.00 0.00 0.00 Infiltration 1,027.62 592.77 -3,524.58 Sup. Fan Heat 2,624.76 2,624.76 0.00 Ret. Fan Heat 0.00 0.00 0.00 Duct Heat Pkup 1,615.12 1,615.12 0.00 Exhaust Heat -585.43 -585.43 0.00 Sub Total 9,249.29 6,881.75 18.90 -19,189.40 49.46 OV/UNDR Sizing 0.00 0.00 0.00 Grand Total 48,928.50 42,429.90 -38,800.90 W/Safety Factor 53,821.30 46,672.90 -42,681.00 7 / 14 79 64 44.2% •PERMIr COORD. COP PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-053 DATE: 03/05/13 PROJECT NAME: FUSE NETWORKS SITE ADDRESS: 12628 INTERURBAN AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: 0444 Bis (ding Division Public Works 04,0 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Incomplete ❑ Complete tyl DUE DATE: 03/07/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions k Not Approved (attach comments) ❑ DUE DATE: 04/04/13 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople iliter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&l to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company IECS INC 2069399495 Po Box 19252 Seattle WA 981091252 King Corporation UBI No. 601639846 Status Active License No. IECS***044QL License Type Construction Contractor Effective Date 11/13/1996 Expiration Date 11/20/2014 Suspend Date Specialty 1 Specialty 2 Unused Heating/Vent/Air-Conditioning And Refrig (Hvac/R) Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status SEATTMI038NRSEATTLE MECHANICAL INC Construction Contractor Metal Fabrication Unused 8/19/1997 11/4/2001 Archived Business Owner Information Name Role Effective Date Expiration Date HUMPHREY, GEORGE President 01/01/1980 Bond Information No records found for the previous 6 year period Assignment of Savings Information Page 1 of 2 Savings Assignment of Savings Account Number Effective Date Release Date Assignment Type Impaired Date Amount Received Date 2 10/10/1996 3/4/2009 Bond 08/01/2011 $4,000.00 08/15/2012 Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 14 Allied Property a Cas Ins Co ACP7505636456 08/01/2012 08/01/2013 $1,000,000.00 08/15/2012 13 Twin City Fire Ins Co 52 UUN PE8855 08/01/2011 08/01/2013 08/15/2012 $1,000,000.0007/26/2012 12 WEST AMERICAN INS CO BKW1153913555 08/01/2010 08/01/2011 $1,000,000.00 07/28/2010 11 LIBERTY NORTHWEST INS CORP BKW1053913555 08/01/2009 08/01/2010 $1,000,000.00 07/21/2009 10 FEDERAL MUTUAL INS CO 9821065 08/01/2007 08/01/2009 $1,000,000.00 06/26/2008 9 FEDERATED MUTUAL INS CO 5090561 08/01/2006 08/01/2007 $1,000,000.00 07/31/2006 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period httns://fortress.wa. eov/lni/bbin/Print. asnx 03/18/2013 PROJECT #C-1014 REVIEWED FOR CODE COMPLIANCE APPROVED MAR 13 2013 S 13 +__ S 4111 1374 it IS 4300a ' siCo 514 i CONSTRUCTION TYPE: OCCUPANCY GROUP(5): ZONE: LOT AREA: TENANT SUITE: 2-NE1.11 CARRIER (MODEL 48TC A06) ROOFTOP GAS/ELECTRIC HVAC UNIT AND CURB 1 -NEW CARRIER (MODEL 48TC A04) ROOFTOP GAS/ELECTRIC HVAC UNIT AND CURB I -NEW HONEYWELL T-8000 THERMOSTATS TUKWILA COMMERCE PARK, BUILDING A 12628 INTERURBAN AVE S BUILDING'C TUKWILA, WA 0004800003 0004800003ft V-6 SPRINKLEREc GROUP' 5 OFFICE C /L I 465,295 SQ FT (10.68' ACRES) 8,046 OVERALL 5,069 SF OFFICE LEGAL' DESCRIPTION' LEWIS C C -D C * 31 BEG N 81-44-15 E 199.11 FT FROM He AT END OF CURVE ON CENT LN OF DUWAMISH-RENTON JUNCTION RD 50 HUB BEING APPROX 1200 FT N AND 440 FT W OF 1/4 COR BET, SECS 14 `4 15-23-4 114 N 49-24-00 UJ 2535 FT TN N 09-36-00 E 52 FT TO TRUE BEG TH 5 82-40-30 E 590 FT T14 N 59-22-30 E 64335: FT 114 N 01-51-30 W 343 FT TO LEFT `BANK OF, DUWAMISH RIVER BEING NLY BOUNDRY OF LEWIS D C TN SWLY ALG SD BANK OF RIVER TO PT N 00-39-40 W OF TRUE` BEG TH 5;:00-39-40 E TO TRUE BEG ALSO POR OFDCLYWOFABOVE DESCRIBED LAND SLY 16.15FTAND AI6FT STRIP ADJ AND PAR. TO ELY LN OF R/W OF P S ELEC CO FOR JOINT RE) TGW LOT 41 OF PLAT OF RIVERSIDE INTERURBAN TR5 0. 4, F-4 cq � d xW �c g .� o n a�a U �oo� REVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional pian review fees. SEPARATE PERMIT REQUIRED FOR. Emporinoi ggsebted 4e City of Tukwila BUILDING DIVISION G.MO DATE: 02-24-2013 RECEIVED CITY OF TUKWILA MAR 05 2013 PERMIT CENTER C1 3 Iof PROJECT #C-1014 HVAC PLAN KEYNOTES 1. INSULTATE ALL DUCTWORK PER 2009 WA. STATE ENERGY CODE 2. PROVIDE 7 DAY PROGRAMBLE THERMOSTATE. 3. BALANCE AND COMMISION SYSTEM. PROVIDE REPORT TO OWNER WHEN COMPLETED 4. ROOF TOP UNIT TO BE PROVIDED WITH ECONOMIZER. 5. OUTSIDE AIR REQUIREMENTS WILL BE PROVIDED BY ECONMIZER SEE CALCULATIONS BELOW. 6. THE PROPOSED OCCUPANCY OF 48 PEOPLE. FRESH AIR REQUIMENTS FOR EACH PERSON IS 20CFM PER PERSON. THE ECONMISER IN THE ROOF TOP UNITS WILL PROVE 955CFM OF OUTSIDE AIR. COOLING UNIT WEIGHT CARRIER CARRIER CARRIER RTU 1, NEW CARRIER (MODEL #48TCD06) 5 TON GAS/ELECTRIC HVAC UNIT AND CURB. SEE UNIT SPECIFICATIONS AND INSTALLATIOM THIS SHEET SYSTEM DESCRIPTION PROVIDE ,5 MQW GAS/ELECTRIC ROOF TOP. tIM15WITH NEW WITH DUCTWORK AND DIFFUSERS FOR NEW OFFICE SPACE. INSTALL 2 NEW EXHAUST FANS FOR NEW RESTROOMS. RUN NEW GAS FROM EXISTING GAS LINE TO NEW ROOF TOP UNITS., NEW ROOFTOP UNIT ° ° 60 CFM n — RTU 3, NEW CARRIER 3M TON LGAGAS/ELECTRIC HVAC UNIT AND CURB. SEE UNIT SPECIFICATIONS AND INSTALLA11OM THIS SHEET RTU 2, NEW CARRIER (MODEL #48TCD06) 5 TON GAS/ELECTRIC HVAC UNIT AND CURB. SEE UNIT SPECIFICATIONS AND INSTALLA11OM THIS SHEET COD U ri4 1.6.1 4.4 VD bd 44 C4 REVISION DATE: 02-25-2013 RECEIVED CITY OF TUKWILA MAR 0 5 2013 PERMIT CENTER M1 Rof 3 REVISION DATE: 02-25-2013