Loading...
HomeMy WebLinkAboutPermit M13-057 - SABEY CORPORATION - DATA CENTER ALTERATIONSABEY DATA CENTER 3433 S 120 PL M13-057 City arTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 1023049081 Address: 3433 S 120 PL TIIKW Project Name: SABEY DATA CENTER MECHANICAL PERMIT Permit Number: M13-057 Issue Date: 04/12/2013 Permit Expires On: 10/09/2013 Owner: Name: SABEY CORPORATION Address: 12201 TUKWILA INTL BLVD , 4TH FLOOR 98168 Contact Person: Name: KIRSTEN FAUSKO Address: 1221 2 AV N , KENT WA 98032 Email: KFAUSKO@HERMANSON.COM Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA 98032 Contractor License No: HERMACLOO5BJ Phone: 253 796-5892 Phone: 206-575-9700 Expiration Date: 08/25/2014 DESCRIPTION OF WORK: REPLACE (2) EXISTING 400 -TON AIR COOLED CHILLERS WITH (2) 400 -TON HIGH EFFICIENCY CHILLERS. REPLACE (17) CRAH UNITS WITH (15) HIGH EFFICIENCY CRAH WITH EMC MOTORS. INSTALL (2) NEW 16000 CFM (40 -TON) AIR HANDLING UNITS AND ASSOCIATED DUCTWORK FOR THE UPS ROOM. CONENSATE DRAINS FOR AHU'S AND ALL ASSOCIATED DUCTWORK. Value of Mechanical: 837,265.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $8,136.56 International Mechanical Code Edition: 2009 I hereby certify that I have read and xa 'ned this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complie with, whether specified herein or not. Date: 1l n The granting of this permit does not p s e to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: --eve A4,,s' l -o Date: VO -I% 3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. �e�o nc7 Drinte,1. ne_1')_9n1q • PERMIT CONDITIONS Permit No. M13-057 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ***FIRE DEPARTMENT CONDITIONS*** 13: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 14: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 15: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 16: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 17: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 18: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 19: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and doc: IMC -4/10 M13-057 Printed: 04-12-2013 #2328) • • 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. J... I•Ain A/1A RA11 /1C7 Drin{nrl• AA_17_')A1 a • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) AW -2 -DC'1 11 IS �h 0' MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 1023049081 Site Address: 3433 S 120th Place Suite Number: 4, 5, & 6 Floor: Tenant Name: Sabey Data Center Tukwila PROPERTY OWNER Name: Kirsten Fausko Address: 1221 2nd Ave N Name: Telx Phone: (253) 796-5892 Fax: (253) 796-5992 Email: kfausko@hermanson.com Address: 1 State Street 21st Floor 575-9800 Contr Reg No.: HERMACLOO5BJ Exp Date: 08/25/2014 City: New York State: NY Zip: 10004 CONTACT PERSON — person receiving all project communication Name: Kirsten Fausko Address: 1221 2nd Ave N City: Kent State: WA Zip: 98032 Phone: (253) 796-5892 Fax: (253) 796-5992 Email: kfausko@hermanson.com New Tenant: ❑ Yes m ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Hermanson Address: 1221 2nd Ave N Cit': Kent State: WA Zip: 98032 Phone: (206) 575-9700 Fax: (206) 575-9800 Contr Reg No.: HERMACLOO5BJ Exp Date: 08/25/2014 Tukwila Business License No.: 09-459 Valuation of project (contractor's bid price): $ 837,265 Describe the scope of work in detail: Replace two (2) existing 400 ton air cooled chillers with two (2) 400 ton high efficiency chillers. Replace seventeen (17) CRAH units with fifteen (15) high efficiency CRAH with ECM motors. Install two (2) new 16,000 cfm (40ton) air handling units and associated ductwork for the UPS room. Condensate drains for AHU's. And all associated ductwork. Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement m Fuel Type: Electric ❑ Gas ❑ Other: H: \Applications\Form-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 1 of 2 4 • Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu I Floor fumace Suspended/wall/floor mounted heater L Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit 14 <10,000 cfrn Unit Type Qty Air handling unit >10,000 cfm I Evaporator cooler Ventilation fan connected to single duct L Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 Intemational Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNS UTHORIZED AGENT: Signature: Date: Print Name: Kirsten Fausko Day Telephone: (253) 796-5892 Mailing Address: 1221 2nd Ave N Kent WA 98032 City State Zip H.ApplicationsWorms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 1023049081 Address: 3433 S 120 PL TURIN Suite No: Applicant: SABEY DATA CENTER RECEIPT Permit Number: M13-057 Status: APPROVED Applied Date: 03/19/2013 Issue Date: Receipt No.: R13-01307 Payment Amount: $6,509.25 Initials: JEM Payment Date: 04/12/2013 12:26 PM User ID: 1165 Balance: $0.00 Payee: KRISTEN FAUSKO, HERMANSON COMPANY LLP TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 137899 ACCOUNT ITEM LIST: Description 6,509.25 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 6,509.25 Total: $6,509.25 Drin+nrl• !lA_1 O_9Al • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 1023049081 Address: 3433 S 120 PL TUKW Suite No: Applicant: SABEY DATA CENTER RECEIPT Permit Number: M13-057 Status: PENDING Applied Date: 03/19/2013 Issue Date: Receipt No.: R13-01087 Payment Amount: $1,627.31 Initials: JEM Payment Date: 03/19/2013 01:04 PM User ID: 1165 Balance: $6,509.25 Payee: KIRSTEN FAUSKO, HERMANSON CO LLP TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 519140 ACCOUNT ITEM LIST: Description 1,627.31 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 1,627.31 Total: $1,627.31 DAM.M. n1_1(1.)n11 INSTION NO. INSPECTION RECORD Retain a copy with permit 03-057 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: -._5/1a / z>47.9 ()hove Type of Inspection: ,c i A/96 Address: 34/33 S /26 PZ__- Date Called: Special Instructions: i"----,re5,474/4-/ ,...137/, t.)rZ•%(� ;� Date Wanted: D - /9—/ 3 p.m Requester: , Phone No: Approved per applicable codes. MENTS: Corrections required prior to approval. 5Aio 664,00 --Oppeaci Perm=- -6, le k //4L Insp n pp INSPECTION FEE EQUIRED. Priof to next inspection. fee must be aid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Date: /0-1.s-3 of l INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 R (206) 431-3670 Permit Inspection Request Line (206) 431-2451 JNi(3-o5'7 Project: 54 8,--f IJ f} Type of Inspection: ._ . 5 /114lt-(_ .65'H? r; J!/2/•/A1 —A1,41- Address: 3133 iaa PL Date Called: Special Instructions: Date Wanted:. 7-3/—/3 13. p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: (1) 4)/5A -,;t - ,op. , 5 /114lt-(_ .65'H? r; J!/2/•/A1 —A1,41- 4 P) pe- t n/S a Go9 J 10-)L.1 — 4/0/fetkod a Inspe • or: lic•+�v�S l 1 Date' 1-2/—/ RINSPECTION FEE REQUIRED. Prior to next inspection. fee must be p id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION c-- 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ' (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Al 3-057 Pro'ecx: �Q-'e: -..A--11-4 Type of Inspect ion:. ( ; u t t i b U �... .�- .5 /: Address: 31 ` 170-D1_... Date Called: Special Instructions: 1 _, Date Wanted: �: _ f '.ra me p.m. Requester: Phane Lk) Co .- 2,C5*- 3(.0 ? 1 Approved per applicable codes. 0 Corrections required prior to approval. COMMENTS: 4.1 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. 1 Inspector: Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 fil/1-057 Project ‘6...V.LX Type of Inspection: g/DiOh -,l,V - -- ' //4f /,, ;f Address: /,O P1 — Date Called: _74/33 Special Instructions: Date Wanted:. 1.-A_ r.. � $.m p.m. Requester: 14",G's0'✓,A/ Phone No: _ -(-0//-7_`J �`-;-.:S1-- 7/ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Pf 4 Dt -----/,-,;,n 2/,tJ/ fS - p,4,,; 5 '-C / n?�c ,G, - .,^✓ .. /*/„),r; , 1 rlvr�y' 0/ 4 /5, n,/7•1 s ,5 0-7 �-�' it7 Pf LTA, s v. /4 //l...r✓ -- 14",G's0'✓,A/ Yu, / 7f Date nPECTION FEE REQUIRED. Prior to nit inspection. fee must be ili gad at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 v.. (206) 431.-3670 Permit Inspection Request Line (206) 431-2451 aM 13-0S? Pr ect: 1 Type of Insp etion: .:� AddCess:, ! 11 n� Date alled6i Speciallnstructions:/ 1 Date Wanted:. ' ,'aa m_,�; "4 --1-g-'(137 • :p.m. Requester: Phoa No: rte, (, —2, --57 r3,- c1,7 ElApproved per applicable codes. Corrections required prior to approval. 7-19 40 COMMENTS: ( 2, p S 12-4 c9 Inspector: AiL it REINSPECTION FEE REQUIRED` Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection: Date.:` INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit M/3 -0S-7 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 \L Project:�� L Sprinklers: Fire Alarm: Type of spection: Address: 31433 Suite #: S/ o4- 91 Contact Person: Special Instructions: Phone No.: 1%Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: 5,14014e sDd,)it) 1s 4),f.'" ±r±.° \\% Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: 7iX7\ Date: /op c/ L3 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 detail c—c i\A 13 -(157 5*-S-e_L( 3A-eN • EXIST. 4x14 w/SCABBED CONT. 2x6 1-- L 3x3x 1/4x0"-8" w/2-5/8"0 LAG BOLTS ® 5"ga. EMBED 3" MIN 2'-0" TYP. 2'-0" X BRACING STRAP–SIMPSON CS.16 ATTACH TO PURUN PER. DTL. 'c–c ABOVE & w/ 2-0.145"0 HILTI X–EDNR FASTENERS, BOT. 1 SECTIO\ 2'-0" ! 2'-0" TYP. 5/8"0 ALL THREAD ROD w/ DOUBLE NUT TOP & BOT. ---SUSPENDED DUCT 80 LBS MAX WEIGHT CITY OF TU �D KwILA APR 15 2013 PERMIT CENTER DUCT SUPP. 3/4" = T _DRWN: L X --• DML ENG'D: D. LAKE — - -JOB NO: 00049017 DUCT SUPPORT DETAIL DATE: 4/5/13 SHEET: ENGINEERS NORTHWEST, INC. 6869 WOODLAWN AVE. N.E. SEATTLE, WASHINGTON 98115 AIRIEST a.., Co. Inc. Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-101 AREA: Suite 1 * Notes Tested By: Nick Wright Test Date: May 13, 2013 SYSTEM/UNIT: CRAH-201 AREA: Suite 2 Tested By: Nick Wright Test Date: May 13, 2013 c:. CITY OF TUKWILA •"' JUL 0 2 2013 SYSTEM/UNIT: CRAH-301 AREA: Suite 3 Design External SP 0.2 in. we * Notes �T CEN1 CR PERMIT CENTER Tested By: Nick Wright Test Date: May 13, 2013 Total Supply CFM Des. 24,000 CFM Airtest Co Inc Preliminary Report Paae 1 of 23 AHRT -LI' ST Coo/ nc o Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-401 AREA: Suite 4 * Notes Tested By: Nick Wright Test Date: May 13, 2013 Air Test Data Total Supply CFM Des. 24,000 CFM SYSTEM/UNIT: CRAH-501 AREA: Suite 5 Unit Data Unit Data Location Service Suite 4 Suite 4 Fan RPM Actual 1139 (x3) RPM Test Data Design External SP 0.2 in. wc * Notes Tested By: Nick Wright Test Date: May 13, 2013 Air Test Data Total Supply CFM Des. 24,000 CFM SYSTEM/UNIT: CRAH-501 AREA: Suite 5 Unit Data Location Suite 5 Service Suite 5 Unit Manufacturer Liebert Unit Model Number CW -181 DC1A1 5097 Unit Serial Number N13C170002 Test Data Design External SP 0.2 in. wc CRAH-501 / Supply Fan (X 31 Fan RPM Actual 1139 (x3) RPM Drive Type Direct Drive Electrical Test Data CRAH-501 / Supply Fan (X 31 Motor Volts 1 (478) (476) (478) Volts Motor Volts 2 (476) (478) (476) Volts Motor Volts 3 (478) (476) (478) Volts Motor Amps 1 (2.9) (2.9) (3.1) Amps Motor Amps 2 (2.6) (2.8) (2.8) Amps Motor Amps 3 (2.4) (2.3) (2.3) Amps * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 Motor Data CRAH-501 / Supply Fan (X 31 Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 Sheave Data CRAH-501 / Supply Fan (X 31 Drive Type Direct Drive Air Test Data Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 22875 CFM Filter Data CRAH-501 / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size .21.5x24x4 Inches CRAH-501 CRAH-501 17 -May -13 Adam Hoskins Fan was balanced at 75% speed. 17 -May -13 Adam Hoskins When we first started balancing the units there were over 100 tiles out. As the day went on tiles were put in place. This effected fan speeds slightly because of the static buildup. The fan speed ranges are set at the balanced speed for high. 5% less for the low. Airtest Co Inc Preliminary Report Page 2 of 23 AIILTES Co., Inc. Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-502 AREA: Suite 5 glia aIDD Location Service Unit Manufacturer Unit Model Number Unit Serial Number Suite 5 Suite 5 Liebert CW -181 DC1A15097 NC13C170006 EDM Papst 5.36 HP 480 Volts 3 60 Hz 5.2 Mips 1.00 Motor Manufacturer Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor Design External SP CRAH-502 / Supply Fan (X 3) 0.2 in. we 1209 (x3) RPM Fan RPM Actual CRAH-502 / Supply Fan (X 3) (477) (477) (477) Volts (476) (478) (478) Volts (478) (476) (478) Volts (2.9) (3.1) (2.9) Amps (2.8) (2.9) (2.9) Amps (2.5) (2.6) (2.2) Amps Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 I Mo or CRAH-502 / Supply Fan (X 3) EDM Papst 5.36 HP 480 Volts 3 60 Hz 5.2 Mips 1.00 Motor Manufacturer Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor CRAH-502 / Supply Fan (X 3) Direct Drive Drive Type Total Supply CFM Des. Total Supply CFM Act. 24,000 CFM 22073 CFM Ltif CRAH-502 / SF Filter Bank Liebert Corporation Pleated 10 21.5x24x4 Inches Filter Manufacturer Filter Type Filter Quantity Filter Size CRAH-502 17 -May -13 Adam Hoskins Fan was balanced at 80% speed. Airiest Co Inc Preliminary Report Page 3 of 23 AIRTES T Co., Inc. Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-503 AREA: Suite 5 Da [tin Location Suite 5 Service Suite 5 Unit Manufacturer Liebert Unit Model Number CW-181DC1A1S097 Unit Serial Number NC13C170003 1 Vil Lein Design External SP 0.2 in. we CRAH-503 / Supply Fan (X 31 Fan RPM Actual 1211 (x3) RPM CRAH-503 / Supply Fan (X 31 Motor Volts 1 (477) (477) (477) Volts Motor Volts 2 (476) (476) (476) Volts Motor Volts 3 (477) (478) (478) Volts Motor Amps 1 (3.8) (3.9) (3.8) Amps Motor Amps 2 (3:8) (3.6) (3.6) Amps Motor Amps 3 (3.3) (3.2) (3.1) Amps * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 rAvikkgr 0j CRAH-503 / Supply Fan (X 31 ' Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 CRAH-503 / Supply Fan (X 31 Drive Type Direct Drive Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 22709 CFM Ma? CEIL:1 CRAH-503 / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size 21.5x24x4 Inches CRAH-503 17 -May -13 Adam Hoskins Fan was balanced at 80% speed. Airiest Co Inc Preliminary Report Page 4 of 23 AIRTEST Co., Air Handling Unit PROJECT: Sabey = Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-504 AREA: Suite 5 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 Mo or[p CRAH-504 / Supply Fan (X 31 Location Service Unit Manufacturer Unit Model Number Unit Serial Number Suite 5 Suite 5 Liebert CW-181DC1A1S097 N13C170015 CRAH-504 / Supply Fan (X 31 Drive Type Direct Drive Design External SP CRAH-504 / Supply Fan (X 31 0.2 in. we 1215 (x3) RPM Fan RPM Actual att CRAH-504 / Supply Fan (X 3) (475) (475) (475) Volts (474) (474) (474) Volts (475) (475) 476) Volts (3.5) (3.9) (4.0) Amps (3.3) (3.8) (3.8) Mips (3.1) (3.4) (3.5) Amps Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 Mo or[p CRAH-504 / Supply Fan (X 31 Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 gi)2ERig ail,_ CRAH-504 / Supply Fan (X 31 Drive Type Direct Drive Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 22246 CFM CRAH-504 / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size 21.5x24x4 Inches CRAH-504 17 -May -13 Adam Hoskins Fan was balanced at 80% speed. Airtest Co Inc Preliminary Report Page 5 of 23 AIRTEST Co. Inc. Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-505 AREA: Suite 5 IAA CO2E1 1 Location Service Unit Manufacturer Unit Model Number Unit Serial Number Suite 5 Suite 5 Liebert CW-181DC1A1S097 N13C170014 CRAH-505 / Supply Fan (X 31 Design External SP CRAH-505 / Supply Fan (X 31 0.2 in. we 1212 (x3) RPM Fan RPM Actual Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 24133 CFM CRAH-505 / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size 21.5x24x4 Inches CRAH-505 / Supply Fan (X 3) (476) (476) (475) Volts (474) (474) (474) Volts (475) (476) (476) Volts (3.5) (3.9) (3.4) Amps (3.3) (3.3) (3.1) Amps (2.9) (3.0) (2.7) Amps Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 Mo o? l CRAH-505 / Supply Fan (X 31 Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 CRAH-505 / Supply Fan (X 31 Drive Type Direct Drive At --17;g10EL:1 Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 24133 CFM CRAH-505 / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size 21.5x24x4 Inches CRAH-505 17 -May -13 Adam Hoskins Fan was balanced at 80% speed. Ainest Co Inc Preliminary Report Page 6 of 23 AIRTES:T Co. Inc< Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-506 AREA: Suite 5 DIM EXII Location Service Unit Manufacturer Unit Model Number Unit Serial Number Suite 5 Suite 5 Liebert CW -181 DC1A1S097 N13C170014 gia;aq; C916 i Design External SP CRAH-506 / Supply Fan (X 3) 0.2 in. we 1152 (x3) RPM Fan RPM Actual CRAH-506 / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size 21.5x24x4 Inches CRAH-5061 Supply Fan (X 31 (475) (475) (475) Volts (473) (473) (474) Volts (475) (475) (475) Volts (2.9) (3.1) (3.1) Amps (2.6) (2.7) (2.8) Amps (2.3) (2.4) (2.4) Amps Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 Motor Com CRAH-506 / Supply Fan (X 31 Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps ' Motor Service Factor 1.00 gia;aq; C916 CRAH-506 / Supply Fan (X 31 Drive Type Direct Drive Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 23239 CFM CRAH-506 / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size 21.5x24x4 Inches CRAH-506 17 -May -13 Adam Hoskins Fan was balanced at 75% speed. Airtest Co Inc Preliminary Report Page 7 of 23 AIRTEST C.., Inc. ivri4S <m ._ <r��< Air. Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-507 AREA: Suite 5 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 Moo F CRAH-507 / Supply Fan (X 31 Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 Location • Service Unit Manufacturer Unit Model Number Unit Serial Number Suite 5 Suite 5 Liebert CW-181DC1A1S097 N13C170017 CRAH-507 / Supply Fan (X 31 Drive Type Direct Drive Qf:71J off_ Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 24199 CFM Design External SP CRAH-507 / Supply Fan (X 31 0.2 in. we 1220 (x3) RPM Fan RPM Actual CRAH-507 / Supply Fan (X 31 (476) (475) (474) Volts (474) (473) (474) Volts (475) (475) (475) Volts (3.4) (3.7) (3.5) Amps (3.2) (3.3) (3.3) Amps (2.9) (3.0) (2.8) Amps Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 Moo F CRAH-507 / Supply Fan (X 31 Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 CRAH-507 / Supply Fan (X 31 Drive Type Direct Drive Qf:71J off_ Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 24199 CFM MOT af- CRAH-507 / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size 21.5x24x4 Inches CRAH-507 17 -May -13 Adam Hoskins Fan was balanced at 80% speed. Air -test Co Inc Preliminary Report Page 8 of 23 AIRTEST Co., Inc. Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-508 AREA: Suite 6 LAM calh=1 Location Service Unit Manufacturer Unit Model Number Unit Serial Number Suite 6 Suite 6 Liebert CW -181 DC1A1S097 N13C170016 Motor Manufacturer EDM Papst Motor RPM 1253 (x3) RPM Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 J Design External SP CRAH-508 / Supply Fan (X 3) 0.2 in. we 1253 (x3) RPM Fan RPM Actual Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 23835 CFM Mita? rafit CRAH-508 / Supply Fan (X 3) (474) (474) (474) Volts (473) (473) (473) Volts (475) (474) (474) Volts (3.6) (4.0) (3.9) Amps (3.5) (3.7) (3.6) Amps (3.2) (3.3) (3.2) Amps Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 oto_Dein CRAH-508 / Supply Fan (X 3) Motor Manufacturer EDM Papst Motor RPM 1253 (x3) RPM Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 CRAH-508 / Supply Fan (X 31 Drive Type Direct Drive Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 23835 CFM Mita? rafit J CRAH-508 / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size 21.5x24x4 Inches CRAH-508 17 -May -13 Adam Hoskins Fan was balanced at 83% speed. Aiitest Co Inc Preliminary Report Page 9 of 23 Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-601 AREA: Suite 6 MiCIP aliE Location Suite 6 Service Suite 6 Unit Manufacturer Liebert Unit Model Number CW -181 DC1A1 5097 Unit Serial Number N13C170024 Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 Design External SP 0.2 in. we CRAH-601 / Supply Fan (X 3) Fan RPM Actual 1262 (x3) RPM CRAH-601 / Supply Fan (X 3) §bgt1112Ell]iftg2 CRAH-601 / Supply Fan (X 3) Motor Volts 1 (477) (476) (477) Volts Motor Volts 2 (477) (477) (478) Volts Motor Volts 3 (476) (476) (477) Volts Motor Amps 1 (2.9) (3.3) (3.0) Amps Motor Amps 2 (2.8) (2.9) (2.8) Amps Motor Amps 3 (2.5) (2.5) (2.4) Amps * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 . Motor CRAH-601 / Supply Fan (X 3) Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 1 CRAH-601 / Supply Fan (X 3) Drive Type Direct Drive Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 23438 CFM MDT IT&L6 CRAH-601 / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size 21.5x24x4 Inches CRAH-601 17 -May -13 Adam Hoskins Fan was balanced at 83% speed. Airiest Co Inc Preliminary Report Page 10 of 23 AIlZTEST Co., Ince Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-602 AREA: Suite 6 . (DM C615 Location Suite 6 Service Suite 6 Unit Manufacturer Liebert Unit Model Number CW -181 DC1A1S097 Unit Serial Number N13C170022 Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 Design External SP 0.2 in. we CRAH-602 / Supply Fan (X 3) Fan RPM Actual 1268 (x3) RPM Drive Type Direct Drive gilaili- CRAH-602 / Supply Fan (X 3) Motor Volts 1 (477) (478) (478) Volts Motor Volts 2 (478) (477) (476) Volts Motor Volts 3 (477) (478) (479) Volts Motor Amps 1 (2.4) (2.7) (2.5) Amps Motor Amps 2 (2.3) (2.3) (2.4) Amps Motor Amps 3 (2.1) (2.1) (1.9) Amps * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 Motor Com CRAH-602 / Supply Fan (X 3) Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 CRAH-602 / Supply Fan (X 3) Drive Type Direct Drive at V;42 IDEI Total Supply CFM Des. 24,000 CFM Total Supply CFM Act. 24298 CFM Ma? CRAH-602 / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size 21.5x24x4 Inches CRAH-602 17 -May -13 Adam Hoskins Fan was balanced at 80% speed. Airtest Co Inc Preliminary Report Page 11 of 23 AIRTEST Co.. Inc. Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-603 AREA: Suite 6 glia afiEl Location Service Unit Manufacturer Unit Model Number Unit Serial Number Suite 6 Suite 6 Liebert CW -181 DC1A1 5097 N13C170013 '1_1 riEfAD Design External SP CRAH-603 / Supply Fan (X 31 0.2 in. we 1294 (x3) RPM Fan RPM Actual I CRAH-603 / Supply Fan (X 31 Direct Drive CRAH-603 1 Supply Fan (X 31 (478) (480) (479) Volts (476) (478) (480) Volts (477) (478) (479) Volts (2.6) (2.3) (2.1) Amps (2.6) (2.6) (2.6) Amps (2.7) (3.0) (2.9) Amps Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 I�ooCn- CRAH-603 / Supply Fan (X 31 EDM Papst 5.36 HP 480 Volts 3 60 Hz 5.2 Mips 1.00 Motor Manufacturer Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor I rDE C.J I CRAH-603 / Supply Fan (X 31 Direct Drive Drive Type Total Supply CFM Des. Total Supply CFM Act. 24,000 CFM 23107 CFM J CRAH-603 / SF Filter Bank Liebert Corporation Pleated 10 21.5x24x4 Inches Filter Manufacturer Filter Type Filter Quantity Filter Size (CRAH-603 17 -May -13 Adam Hoskins Fan was balanced at 86% speed. Airiest CO Inc Preliminary Report Page 12 of 23 AIRTES'I' Co., Inc. Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-604 fans / fuse AREA: Suite 6 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 Motor CL AV [Lain Location Service Unit Manufacturer Unit Model Number Unit Serial Number Suite 6 Suite 6 Liebert CW -181 DC1A1 5097 N13C170023 CRAH-604 fans / fuse / Supply Fan (X 31 Drive Type Direct Drive Total Supply CFM Des. 24,000 CFM Design External SP 0.2 in. we * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 Motor CL CRAH-604 fans / fuse / Supply Fan (X 31 Motor Manufacturer EDM Papst Motor HP 5.36 HP Motor Rated Volts 480 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 5.2 Amps Motor Service Factor 1.00 §039EV-0 DEI) CRAH-604 fans / fuse / Supply Fan (X 31 Drive Type Direct Drive Total Supply CFM Des. 24,000 CFM CRAH-604 fans / fuse / SF Filter Bank Filter Manufacturer Liebert Corporation Filter Type Pleated Filter Quantity 10 Filter Size 21.5x24x4 Inches CRAH-604 fans / fuse / Supply Fan (X 3) CRAH-604 fans / fuse / Supply Fan (X 3) 17 -May -13 Adam Hoskins 17 -May -13 Adam Hoskins Item 0001 : Fans are making a scraping sound on start up. I turned it off immediately. Item 0002: Bad fuse to middle fan. Far left phase. Airtest Co Inc Preliminary Report Page 13 of 23 AIRTEST Co., Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-605 AREA: Suite 6 Ma acE Location Service Unit Manufacturer Unit Model Number Unit Serial Number Suite 6 Suite 6 Liebert CW -181 DC1A1S097 N13C170029 EDM Papst 5.36 HP , 480 Volts 3 60 Hz. 5.2 Amps 1.00 Motor Manufacturer Motor HP Motor Rated Volts Motor Phase Motor Hertz - Motor FL Amps Motor Service Factor Design External SP CRAH-605 / Supply Fan (X 31 0.2 in. we 1297 (x3) RPM Fan RPM Actual I CRAH-605 / Supply Fan (X 31 (478) (478) (478) Volts (478) (478) (478) Volts (475) (476) (476) Volts (2.9) (3.1) (2.0) Amps (2.7) (2.7) (2.7) Amps (2.4) (2.4) (2.3) Amps Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 I 0 0 0 JI CRAH-605 / Supply Fan (X 31 EDM Papst 5.36 HP , 480 Volts 3 60 Hz. 5.2 Amps 1.00 Motor Manufacturer Motor HP Motor Rated Volts Motor Phase Motor Hertz - Motor FL Amps Motor Service Factor CRAH-605 / Supply Fan (X 31 Direct Drive Drive Type Total Supply CFM Des. Total Supply CFM Act. 24,000 CFM 23272 CFM CRAH-605 / SF Filter Bank Liebert Corporation Pleated 10 21.5x24x4 Inches Filter Manufacturer Filter Type Filter Quantity Filter Size CRAH-605 17 -May -13 Adam Hoskins Fan was balanced at 86% speed. Airtest Co Inc Preliminary Report Page 14 of 23 AIRTEST Co., Air Handling Unit PROJECT: Sabey --Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/,UNIT: CRAH-606 AREA: Suite 6 gtlia of Location Service Unit Manufacturer Unit Model Number Unit Serial Number Suite 6 Suite 6 Liebert CW -181 DC1A1S097 N13C170004 EDM Papst 5.36 HP 480 Volts 3 60 Hz 5.2 Amps 1.00 Motor Manufacturer Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor IL:1 Design External SP CRAH-606 / Supply Fan (X 3) 0.2 in. we 1268 (x3) RPM Fan RPM Actual Direct Drive CRAH-606 / Supply Fan (X 3) _ (477) (477) (479) Volts (475) (476) (477) Volts (477) (477) (479) Volts (2.8) (3.1) (3.1) Amps (2.7) (2.8) (2.8) Mips (2.3) (2.4) (2.4) Amps Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 o - Motor Dein CRAH-606 CRAH-606 / Supply Fan (X 31 EDM Papst 5.36 HP 480 Volts 3 60 Hz 5.2 Amps 1.00 Motor Manufacturer Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor CRAH-606 / Supply Fan (X 31 Direct Drive Drive Type Total Supply CFM Des. Total Supply CFM Act. 24,000 CFM 22842 CFM CRAH-606 / SF Filter Bank Liebert Corporation Pleated 10 21.5x24x4 Inches • Filter Manufacturer Filter Type Filter Quantity Filter Size CRAH-606 17 -May -13 Adam Hoskins Fan was balanced at 83% speed. Airtest Co Inc Preliminary Report Page 15 of 23 AIRTEST Co., Inc. Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-607 AREA: Suite 6 Rd Location Service Unit Manufacturer Unit Model Number Unit Serial Number Suite 6 Suite 6 Liebert CW-181DC1A1S097 N13C170030 Ul Motor Manufacturer Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor Design External SP CRAH-607 / Supply Fan (X 31 0.2 in. we 1177 (x3) RPM Fan RPM Actual CRAH-607 / Supply Fan (X 31 Direct Drive Drive Type CRAH-607 / Supply Fan (X 31 (477) (477) (478) Volts (476) (477) (477) Volts (477) (475) (476) Volts (3.0) (3.9) (2.4) Amps (2.7) (2.1) (2.4) Amps (2.4) (2.8) (2.3) Amps Motor Volts 1 • Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: May 17, 2013 MoorE CRAH-607 / Supply Fan (X 31 EDM Papst 5.36 HP 480 Volts 3 60 Hz 5.2 Amps 1.00 Motor Manufacturer Motor HP Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor CRAH-607 / Supply Fan (X 31 Direct Drive Drive Type Total Supply CFM Des. Total Supply CFM Act. 24,000 CFM 23305 CFM — — — — i CRAH-607 / SF Filter Bank Liebert Corporation Pleated 10 21.5x24x4 Inches Filter Manufacturer Filter Type Filter Quantity Filter Size CRAH-607 17 -May -13 Adam Hoskins Fan was balanced at 77% speed. Airiest Co Inc Preliminary Report Page 16 of 23 RTEST Co., Inc. Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-U01 AREA: UPS * Notes Tested By: Adam Hoskins Test Date: June 11, 2013 0 ori Location Service Unit Manufacturer Unit Model Number Unit Serial Number CRAH-U01 / Supply Fan UPS UPS Liebert CW-114UCVA1A608 N13E140018 FC Fan Type / Class Motor Manufacturer -Baldor. Motor HP 10 HP Motor RPM 1770 RPM Motor Frame 215T Motor Rated Volts 460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 12.5 Amps Motor Service Factor 1.15 U Design External SP Actual Ext. SP Suction Actual Ext. SP Discharge Actual Total Ext. SP CRAH-U01 / Supply Fan 1.0 in. wc -0.15 in. wc 0.44 in. wc 0.59 in. wc 730 RPM Fan RPM Actual Drive Type Belt Belt Size BX40 Number of Belts 2 Motor Sheave 2BK47 Motor Sheave Bore H 1 3/8 in. Fan Sheave 2B5V86 Fan Sheave Bore B 1 7/16 in. Sheave Center Line 10 3/4 in. 1 CRAH-U01 1 Supply Fan 483 Volts 483 Volts 486 Volts 3.0 Amps 3.0 Amps 2.3 Amps Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: June 11, 2013 0 ori CRAH-U01 / Supply Fan Motor Manufacturer -Baldor. Motor HP 10 HP Motor RPM 1770 RPM Motor Frame 215T Motor Rated Volts 460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 12.5 Amps Motor Service Factor 1.15 CRAH-U01 / Supply Fan r Drive Type Belt Belt Size BX40 Number of Belts 2 Motor Sheave 2BK47 Motor Sheave Bore H 1 3/8 in. Fan Sheave 2B5V86 Fan Sheave Bore B 1 7/16 in. Sheave Center Line 10 3/4 in. Total Supply CFM Des. 10000 CFM Total Supply CFM Act. 9651 CFM OA CFM Design 10000 CFM OA CFM Actual 9651 CFM 1I Q J CRAH-U01 / SF Filter Bank Filter Manufacturer Liebert Filter Type Pleated MERV Rating 8 Filter Quantity 10 Filter Size 18x24x4 Inches CRAH-U01 11 -Jun -13 Adam Hoskins CRAH-U01 11 -Jun -13 Adam Hoskins All 3 of the units were running during balance. Fan was balanced at 79% speed. Afrtest Co Inc Preliminary Report Page 17 of 23 Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-UO2 AREA: UPS gait CiEf_ Location UPS Service UPS Unit Manufacturer Liebert Unit Model Number CW-114UCVA1A608 Unit Serial Number N13E140019 CRAH-UO2 1 Supply Fan Fan Type / Class FC itga a1111_ Design External SP 1.0 in. wc Actual Ext SP Suction -0.34 in. wc Actual Ext. SP Discharge 0.31 in. wc Actual Total Ext. SP 0.65 in. wc CRAH-UO2 / Supply Fan Fan RPM Actual 832 RPM CRAH-UO2 /Supply Fan Motor Volts 1 484 Volts Motor Volts 2 485 Volts Motor Volts 3 483 Volts Motor Amps 1 4.1 Amps Motor Amps 2 4.2 Amps Motor Amps 3 3.8 Amps * Notes Tested By: Adam Hoskins Test Date: June 11, 2013 oto CRAH-UO2 / Supply Fan J Motor Manufacturer Baldor Motor HP 10 HP Motor RPM 1770 RPM Motor Frame 215T Motor Rated Volts 460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 12.5 Amps Motor Service Factor 1.15 ,§1IGOWG DEM CRAH-UO2 / Supply Fan Drive Type Belt Belt Size BX40 Number of Belts 2 Motor Sheave 2BK47 Motor Sheave Bore H 1 3/8 in. Fan Sheave 2B5V86 Fan Sheave Bore B 1 7/16 in. Sheave Center Line 10 3/4 in. Total Supply CFM Des. 10000 CFM Total Supply CFM Act. 10335 CFM OA CFM Design 10000 CFM OA CFM Actual 10335 CFM CRAH-UO2 / SF Filter Bank Filter Manufacturer Liebert Filter Type Pleated MERV Rating 8 Filter Quantity 10 Filter Size 18x24x4 Inches CRAH-UO2 CRAH-UO2 11 -Jun -13 Adam Hoskins All 3 of the units were running during balance. 11 -Jun -13 Adam Hoskins Fan was balanced at 90% speed. Airtest Co Inc Preliminary Report Page 18 of 23 Al TEST Co,, Inc. Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-UO3 AREA: UPS * Notes Tested By: Adam Hoskins Test Date: June 11, 2013 Mo or Cein CRAH-UO3 / Supply Fan Motor Manufacturer Baldor Motor HP 10 HP Motor RPM 1770 RPM Motor Frame 215T Motor Rated Volts 460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 12.5 Amps Motor Service Factor 1.15 CRAH-UO3 / Supply Fan Drive Type Belt Size Number of Belts Motor Sheave Motor Sheave Bore Fan Sheave Fan Sheave Bore Sheave Center Line Belt BX40 2 2BK47 H 1 3/8 in. 2B5V86 B 1 7/16 in. 10 3/4 in. Total Supply CFM Des. Total Supply CFM Act. OA CFM Design OA CFM Actual 10000 CFM 10074 CFM 10000 CFM 10074 CFM Ma? IDEL=1 CRAH-UO3 / SF Filter Bank Filter Manufacturer Filter Type MERV Rating Filter Quantity Filter Size Liebert Pleated 8 10 18x24x4 Inches CRAH-UO3 11 -Jun -13 Adam Hoskins All 3 of the units were running during balance. CRAH-UO3 11 -Jun -13 Adam Hoskins Fan was balanced at 95% speed. Airtest Co Inc Preliminary Report Page 19 of 23 Location Service Unit Manufacturer Unit Model Number Unit Serial Number CRAH-UO3 / Supply Fan UPS UPS Liebert CW-114UCVA1A608 N13E140028 FC Fan Type / Class Design External SP Actual Ext SP Suction Actual Ext. SP Discharge Actual Total Ext. SP CRAH-UO3 / Supply Fan 1.0 in. wc -0.61 in. wc 0.51 in. we 1.12 in. wc 878 RPM Fan RPM Actual CRAH-UO3 / Supply Fan 484 Volts 484 Volts 483 Volts 4.3 Amps 4.3 Amps 3.7 Amps Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 * Notes Tested By: Adam Hoskins Test Date: June 11, 2013 Mo or Cein CRAH-UO3 / Supply Fan Motor Manufacturer Baldor Motor HP 10 HP Motor RPM 1770 RPM Motor Frame 215T Motor Rated Volts 460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 12.5 Amps Motor Service Factor 1.15 CRAH-UO3 / Supply Fan Drive Type Belt Size Number of Belts Motor Sheave Motor Sheave Bore Fan Sheave Fan Sheave Bore Sheave Center Line Belt BX40 2 2BK47 H 1 3/8 in. 2B5V86 B 1 7/16 in. 10 3/4 in. Total Supply CFM Des. Total Supply CFM Act. OA CFM Design OA CFM Actual 10000 CFM 10074 CFM 10000 CFM 10074 CFM Ma? IDEL=1 CRAH-UO3 / SF Filter Bank Filter Manufacturer Filter Type MERV Rating Filter Quantity Filter Size Liebert Pleated 8 10 18x24x4 Inches CRAH-UO3 11 -Jun -13 Adam Hoskins All 3 of the units were running during balance. CRAH-UO3 11 -Jun -13 Adam Hoskins Fan was balanced at 95% speed. Airtest Co Inc Preliminary Report Page 19 of 23 AIRTEST Co., Air Handling Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: CRAH-U04 AREA: Future UPS * Notes Tested By: Nick Wright Test Date: May 13, 2013 GNP 1Co Total Supply CFM Des. 10000 CFM SYSTEM/UNIT: CRAH-U05 AREA: Future UPS glia DEtl Location Service Unit Manufacturer Unit Model Number Future US Future UPS Future Future Future US Future UPS Future Future IJi3 Design External SP i 1.0 in. we * Notes Tested By: Nick Wright Test Date: May 13, 2013 GNP 1Co Total Supply CFM Des. 10000 CFM SYSTEM/UNIT: CRAH-U05 AREA: Future UPS * Notes Tested By) Nick Wright Test Date: May 13, 2013 Total Supply CFM Des. 10000 CFM Airiest en Inc Preliminary Report Page 20 of 23 Ntf Location Service Unit Manufacturer Unit Model Number Future US Future UPS Future Future i Design External SP 1.0 in. we * Notes Tested By) Nick Wright Test Date: May 13, 2013 Total Supply CFM Des. 10000 CFM Airiest en Inc Preliminary Report Page 20 of 23 AdRTES`g' Cie, Fan Unit PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: EF -R01 AREA: UPS * Notes Tested By: Nick Wright Test Date: May 13, 2013 Mo or 1 Motor HP Motor Rated Volts Motor Phase Motor Hertz Unit Location Unit Serves Unit Manufacturer Model Number Roof UPS Greenheck GB -121 TO, 4 -fel External SP Design 0.50 in. wc * Notes Tested By: Nick Wright Test Date: May 13, 2013 Mo or 1 Motor HP Motor Rated Volts Motor Phase Motor Hertz 1/2 HP 120 Volts 1 60 Hz Future UPS Greenheck GB -121 Total Fan CFM Des. 1500 CFM SYSTEM/UNIT: EF -R02 AREA: UPS * Notes Tested By: Nick Wright Test Date: May 13, 2013 At RITE) Unit Location Unit Serves Unit Manufacturer Model Number Future UPS Greenheck GB -121 External SP Design 0.50 in. wc * Notes Tested By: Nick Wright Test Date: May 13, 2013 Aii#est Co Inc Preliminary Report Page 21 of 23 00 IDEL Motor HP Motor Rated Volts Motor Phase Motor Hertz 1/2 HP 120 Volts 1 60 Hz Total Fan CFM Des. 1500 CFM Aii#est Co Inc Preliminary Report Page 21 of 23 AIRTEST Co. Hydronic Pump PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: Pump -01 AREA: Pump -01 Balance Valve Summary Airiest Co Inc Preliminary Report Page 22 of 23 �vG��' p k4 I fli ;'iii? 69.0 '{ P, •,c m, ' , y, .. ,I aCRAH-101 CRAH-201 --- 69.0 CRAH-301 --- 69.0 CRAH-401 --_ 69.0 CRAH-501 * Suite 5 TA STAF 2-1/2" 69.0 6.30 67.0 4.0 CRAH-502 Suite 5 TA STAF 2-1/2" 69.0 6.10 66.0 4.0 CRAH-503 * Suite 5 TA STAF 2-1/2" 69.0 1.20 69.0 8.0 CRAH-504 Suite 5 TA STAF 2-1/2" 69.0 6.20 67.0 4.0 CRAH-505 * Suite 5 TA STAF 2-1/2" 69.0 6.30 67.0 4.0 CRAH-506 * Suite 5 TA STAF 2-1/2" 69.0 4.60 71.0 4.5 CRAH-507 Suite 5 TA STAF 2-1/2" 69.0 1.20 69.0 8.0 CRAH-508 * Suite 5 TA STAF 2-1/2" 69.0 7.90 75.0 4.0 CRAH-601 Suite 6 TA STAF 2-1/2" 69.0 6.60 72.0 4.0 CRAH-602 Suite 6 TA STAF 2-1/2" 69.0 6.50 71.0 4.0 CRAH-603 Suite 6 TA STAF 2-1/2" 69.0 6.40 68.0 4.0 CRAH-604 Suite 6 TA STAF 2-1/2" 69.0 1.10 66.0 8.0 CRAH-605 Suite 6 TA STAF 2-1/2" 69.0 6.20 67.0 4.0 CRAH-606 Suite 6 TA STAF 2-1/2" 69.0 5.60 65.0 8 CRAH-607 Suite 6 TA STAF 2-1/2" 69.0 6.90 72.0 4.0 CRAH-U01 valve ___ 50.0 --- CRvaive valve _�- 50.0 --- CR "Ss " AH UO3 valve �� � h d � �.wl I� NF r ,w•a Nn�V� r .I 11AN .... II S 8 ^" v, � __- M Zrai _®�. ,.; ,�G W{' ., "✓<' 1 {IV Y iO h a.., 50.0 in, --- M i ,, JI yw1. .u, s rl G .;�• mP4„1 ul N.ml.• Airiest Co Inc Preliminary Report Page 22 of 23 s.MT= Co., Inc. Hydronic Pump PROJECT: Sabey - Telx Project Hawk LOCATION: Tukwila, WA PROJECT #: 13-2027-1 DATE: 6/27/2013 CONTACT: Adam Hoskins SYSTEM/UNIT: Pump -01 (Cont.) AREA: * Notes Pump -01 Pump -01 / CRAH-501 Pump -01 / CRAH-505 Pump -01 / CRAH-508 Pump -01 / CRAH-U01 valve Pump -01 / CRAH-UO2 valve Pump -01 / CRAH-UO3 valve 21 -May -13 Adam Hoskins The system was balanced with 2 pumps running at 55 HZ. 2 of the chillers were left open. 2 were valved off. 21 -May -13 Adam Hoskins The cap on the low port is missing. 21 -May -13 Adam Hoskins The cap on the low port is missing. 21 -May -13 Adam Hoskins The cap on the high port is missing. 11 -Jun -13 Adam Hoskins Item 0004: Needs valves overridden open at the unit. Valves cannot be manually opened. 11 -Jun -13 Adam Hoskins Item 0005: Needs valves overridden open at the unit. Valves cannot be manually opened. 11 -Jun -13 Adam Hoskins Item 0006: Needs valves overridden open at the unit. Valves cannot be manually opened. Airtast Co Inc Preliminary Report Page 23 of 23 Phase Project Name Location Sabey, Telx Tukwila, Washington Suite Number Area Sq. Ft. Server Load Tons Server Load Btuh Roof Load Btuh P - Lighting at lwsf Btuh PIPLECopPeri*A141 Y Fan Heat (8%) Btuh Total Tons 1 6 7355 201 2,412,000 14,710 25,103 192,960 2,644,773 220 1 5 8394 385 4,620,000 16,788 28,649 369,600 5,035,037 420 2 4 10730 386 4,632,000 21,460 36,621 370,560, 5,060,641 422 2 3 10822 386 4,632,000' 21,644 36,935' 370,560 5,061,139' 422 3 2 9907 221 2,652,000 19,814 33,813' 212,160 2,917,787, 243 3 1 7753 236 2,832,000 15,506 26,461 226,560 3,100,527 258 54961 1815 21780000 109922 187582 Floor Grates at 1100 CFM/grate at 0.06" H2O Phase Suite Number CRAH Quantity Suite Airflow CFM Qty of Floor Grates Chilled Water GPM Chilled Waterflow if N+1 operates 1 6 7 168,000 153 483 552 1 5 6 144,000 131 414 483 2 4 10 240,000; 218 690 759 2 3 10 240,000 218 690 759 3 2 10 240,000 218 690 759 3 1-. 6144,000 131 414 483 Total 1069 3381 3795 1742400 23819904 CODE O1 MPLFOR APPROVED NCE APR 0 9 2013 BU/� NGTukwlla DIVISION 1985 RECEIVED CITY OF TUKWILA MAR 1 9 2013 PERMIT CENTER MtO1 Project Name Location Sabey, Telx Tukwila, Washington Phase UPS Room Area Sa. Ft. UPS Equip UPS Equip Roof Load Lighting at lwsf Fan Heat KW Btuh Btuh Btuh (8%) Btuh Date: 2/13/2013 Total Tons 1 1 1443 2875 343,433 2,886 4,925 27,475 378,719 32 2 2 1313 3320 396,591 2,626 4,481 31,727 435,425 36 6195 •PERMJr COORD CoPr PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-057 PROJECT NAME: SABEY DATA CENTER SITE ADDRESS: 3433 S 120 PL DATE: 03/20/13 X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: t1YvV O Building Division Public Works kti(- -141,0 ■ Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete 111 DUE DATE: 03/21/13 Not Applicable ❑ Comments: Permit Center Use Only. INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 04/18/13 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Peter Friendly Page 1 General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HERMANSON COMPANY LLP UBI No. 602004844 Phone 2065759700 Status Active Address 1221 2Nd Ave N License No. HERMACLOO5BJ Suite/Apt. License Type Construction Contractor City Kent Effective Date 1/11/2000 State WA Expiration Date 8/25/2014 Zip 980322945 Suspend Date County King Specialty 1 General Business Type Limited Liability Partnership Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HERMAC*016RN HERMANSON CORPORATION Construction Contractor General Unused 1/11/2000 8/21 /2002 Archived HERMAC'217NT HERMANSON CORPORATION Construction Contractor Air Heat,Ventilation,Evaporat Metal Fabrication 8/30/1979 8/21/2000 Archived Business Owner Information Name Role Effective Date Expiration Date NICOLAISEN, KNUT H Partner/Member 08/05/2010 Amount BROCK, DANIEL L Partner/Member 08/05/2010 GL0370326109 FOX, DEAN M Partner/Member 08/05/2010 HENGEL, STEPHEN A Partner/Member 08/05/2010 American Zurich Insurance Comp DYCKMAN, KENNETH A Partner/Member 08/05/2010 ROBINETT, PAUL J Partner/Member 08/05/2010 9 HERMANSON, RICHARD L Partner/Member 01/01/1980 08/21/2011 ALMON, KEVIN Partner/Member 01/01/1980 08/05/2010 MACDONALD, JAMES Partner/Member 01/01/1980 08/05/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 WESTERN SURETY CO 929381801 01/01/2006 Until Cancelled $12,000.00 12/01/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 11 American Zurich Insurance Comp GL0370326109 08/21/2012 08/21/2013 $1,000,000.0008/14/2012 10 American Zurich Insurance Comp GL0370326108 08/21/2011 08/21/2012 $1,000,000.0008/18/2011 9 American Zurich Ins Co GL0370326107 08/21/2010 08/21/2011 $1,000,000.0008/18/2010 8 ZURICH AMERICAN INS CO GL0370326106 08/21/2008 08/21/2010 $1,000,000.00 08/24/2009 7 08/21/2004 08/21/2008 $1,000,000.0008/20/2007 https://fortress.wa.gov/lni/bbin/Print.asnx 04/12/2013 S12X1000) b12X100 I ) A AC ACH ACT AD ADD'L AFF AFG AHU ALUM AMP/AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTUH CAP CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU CW DB DDC DEFL DEG DIA DMPR DN DWG EXH EA EAT EC EER EF EFF EL ELEC/ELECT EMCS ENT EQUIP ESP EWT EXIST EXH F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GPM GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX HZ IBC ICW ID MECHANICAL ABBREVIATIONS AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL TILE CEILING ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN / BLACK STEEL BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CONTROLS CONTRACTOR CEILING DIFFUSER/CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CON NECT/CONN ECTED/CON NECTION CONTINUOUS/CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC/CONDENSER UNIT DOMESTIC COLD WATER/CONDENSER WATER DUCTBOARD/DRY BULB/DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/ DEGREES DIAMETER DAMPER DOWN DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION ELECTRICAL/ELECTRIC ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING EXHAUST FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS, INSTALLED BY CONTRACTOR FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE/SMOKE DAMPER FOOT/FEET FUTURE FACE VELOCITY GRILLE GAUGE/GALLON GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE/REGISTER/DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER HERTZ INTERNATIONAL BUILDING CODE INDUSTRIAL COLD WATER INSIDE DIAMETER/DIMENSION E EER MC N N WG PLV KW LAT LB/LBS LF/LIN FT LPG LPS LVG LWA LWG LWT MAX MAU MBH MCA MD M FR MISC MIN MPS MT MTD MUW NA NC NG/NGAS NIC NO NPW N -R OA/OSA OBD OD PCF PD PH POC P/PRESS PSI PSIG QTY R RA RD/RND REF REQ RESID RF RG RL RPM RS S SA SAT SD S/D S_C SEER SENS SL SM SPEC SO SOG SP SF SS STRUC TA TEMP TBD TOD TOS TOT TSP TSTAT TYP UH UNO V VD VEL VERT VFD VOL W WB WG W/ W/0 W/SF WSEC NVERT ELEVATION NTEGRATED ENERGY EFFICIENCY RATIO NTERNATIONAL MECHANICAL CODE NCHES NCHES WATER GAUGE NTEGRATED PART LOAD VALUE KILOWATTS LEAVING AIR TEMPERATURE POUND/POUNDS LINEAL FOOT/FEET LIQUID PROPANE GAS LOW PRESSURE STEAM LEAVING SOUND POWER RATING LEVEL (IN DB) LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM MAKE UP AIR UNIT 1000 BRITISH THERMAL UNITS/HOUR MINIMUM CIRCUIT AMPACITY MOTORIZED DAMPER MANUFACTURER MISCELLANEOUS MINIMUM/MINUTE MEDIUM PRESSURE STEAM MOUNT MOUNTED MAKE-UP WATER NOT APPLICABLE NORMALLY CLOSED/NOISE CRITERIA NATURAL GAS NOT IN CONTRACT NORMALLY OPEN/NUMBER NON -POTABLE WATER NON-RESIDENTIAL OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIAMETER/DIMENSION POUNDS PER CUBIC FOOT PRESSURE DROP PHASE POINT OF CONNECTION PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANITY RETURN GRILLE/RELOCATED/RETURN RETURN AIR ROUND REFERENCE REQUIRED RESIDENTIAL RELIEF REFRIGERANT DISCHARGE GAS REFRIGERANT LIQUID REVOLUTIONS PER MINUTE REFRIGERANT SUCTION SUPPLY SUPPLY AIR SATURATION/SUPPLY AIR TEMPERATURE SMOKE DETECTOR SLIP & DRIVE CONNECTION SEATTLE __ CODE SEASONAL ENERGY EFFICIENCY RATING SENSIBLE SOUND LINED SHEETMETAL SPECIFICATION SCREENED -OPENING SLAB ON' -GRADE STATIC PRESSURE SQUARE FEET STAINLESS STEEL STRUCTURAL TRANSFER AIR TEMPERATURE/TEMPORARY TO BE DETERMINED TOP OF DUCT TOP OF STEEL/TOP OF SLAB TOTAL TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNIT HEATER UNLESS NOTED OTHERWISE VOLT VOLUME DAMPER VELOCITY VERTICAL VARIABLE FREQUENCY DRIVE VOLUME WRAPPED DUCT WET BULB WATER GAUGE WITH WITHOUT WATTS PER SQUARE FOOT WASHINGTON STATE ENERGY CODE MECHANICAL LEGEND 1OX10 10X10 t 10X100 1-10)00E4 z10X10® 10X10 10X10 100 i! 100 b 100 f100 100 BOOT TAP RECT SUPPLY AIR DUCT UP/TOWARD RECT SUPPLY AIR DUCT DN/AWAY RECT EXHAUST OR RETURN DUCT UP/TOWARD RECT EXHAUST OR RETURN DUCT DN/AWAY ROUND DUCT - UP/TOWARD ROUND DUCT - DN/ AWAY FLATOVAL DUCT - UP/ TOWARD FLATOVAL DUCT - DN/ AWAY DUCT OVERLAP =1001 RD z Q z 45° TAP VOLUME DAMPER RISE(R) & DROP(D) TRANSITION TURNING VANES/SPLITTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW (FORCED AIR) -k16X16SL� IQs z lo CD1-100 80 TSTAT/TEMP SENSOR Q HUMIDITY SENSOR 0 SMOKE DETECTOR SP STATIC PRESSURE SENSOR COMBINATION FSD FIRE DAMPER SMOKE DAMPER MOTOR OPERATED DAMPER ACCESS DOORS SOUND TRAP FLEX CONNECTION ACOUSTICALLY LINED DUCT (SL) FABRIC DUCT CLEARANCE SUPPLY AIR DIFFUSER (WITH CORE BLANKOFF) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) REVISION CLOUD & TRIANGLE ROUND DUCT SYMBOL FLATOVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE -CFM SIZE @CARBON DIOXIDE SENSOR Co CARBON MONOXIDE SENSOR z z 0 D t 3 2 da 2-CHWS /CHWR-5 �-- RL/RS-5 z- NG --s 2-- LPG -5 2-CDWS /CDWR-s 2-HWS/HWR-5 2- COND -5 FOV -5 2-- FOS / FOR -s RDG -5 EXISTING DUCTWORK DEMO DUCTWORK WALL -MOUNTED GRILLE PIPE ELBOW UP PIPE ELBOW DN DIRECTION OF FLOW DIRECTION OF SLOPE DOWN PLUG OR CAP PRESS REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY/RETURN REFRIGERANT LIQUID/SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY/RETURN HEATING WATER SUPPLY/RETURN CONDENSATE FUEL OIL VENT FUEL OIL SUPPLY/RETURN REFRIGERANT DISCHARGE GAS SEPA RATE REQUIRED FOR: 0 Elkichanici ,- scat ' Plumbing [' ' Gas Piping Cay of Tukwila BU LDI; NG DIVISION A MECHANICAL GENERAL NOTES 1. WORK SHALL CONFORM TO APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2009 IBC, 2009 WSEC & 2009 IMC 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWISE. 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN ACCOUNTED FOR. 10. OUTSIDE AIR INTAKES ON ALL AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET WITHIN 10 FEET 11. ALL AIR ECONOMIZERS SHALL BE CAPABLE OF THE FOLLOWING: - 0% TO 100% OF THE DESIGN SUPPLY AIR - CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. - INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED (OR GRAVITY DAMPERS PER EXCEPTIONS IN 1412.4.1) WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE. 13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGRAMMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK, AND CAPABLE OF A DEADBAND SEIIING OF AT LEAST 5°F (10°F FOR RESIDENTIAL), BETWEEN THE HEATING AND COOLING SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OF RESETTING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE SAFETY OR HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEISMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER THAN 2000 CFM] OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FIC (ELEC) UNO. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. MECHANICAL ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. MOTOR EFFICIENCIES TO MEET OR EXCEED CODE MINIMUM. 22. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR: - ALL VERTICAL JOINTS & CORNERS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT p SHALL BE CAULKED (BY GC). )FILLING WITH ROCK WOOL IS NOT ACCEPTABLE -- USE SEC ITIT ONT905S OF THE 2009E IBCOFOR CONSTRUCTION LEAKAGE AREA, FOLLOWING THE BE NES FOR TIGHT SIDESTISHAFT CONSTRUCTION. - ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT • MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. 24. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER 5 AND TABLES 5-11 AND 5-12. MINIMUM DUCT INSULATION LAST UPDATED 10/05/12 DUCT TYPE DUCT LOCATION IN HEATED AND MECHANICALLY COOLED DUCT SYSTEM N -R INSULATION R -VALUE RESID INSULATION R -VALUE REMARKS SUPPLY, RETURN NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF BUILDING, ON ROOF, IN ATTIC, IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES R-7 R-8 1,2,3 OUTSIDE AIR WITHIN CONDITIONED SPACE VARIES R-8 1,2,4,5 SUPPLY, RETURN, OUTSIDE AIR NOT WITHIN CONDITIONED SPACE: IN CONCRETE, IN GROUND R-5.3 R-5.0 1,2 SUPPLY AIR <55° OR >105° WITHIN CONDITIONED SPACE R-3.3 NOT REQ 1,2 1 REFER TO ENERGY CODE SECTION 1414.2 FOR FURTHER REQUIREMENTS 2 INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS 3 WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS 4 INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R-7 FOR REST OF INSTALLATION) 5 R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR SYSTEM AND LESS THAN 2,800 CFM MINIMUM PIPE INSULATION LAST UPDATED: 01/09/13 FLUID DESIGN OPERATING TEMP °F INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (IN) CONDUCTIVITY RANGE MEAN TEMP RATING T RUN OUTS* <1 1 TO <1-1/2 1-1/2 TO <4 4 TO <8 >8 HEATING SYSTEMS (STEAM, CONDENSATE, HYDRONIC HOT WATER, DOMESTIC HOT WATER) >350 0.32-0.34 250 3.0 3.0 3.5 3.5 4.5 4.5 251-350 0.29-0.32 200 2.0 2.0 3.0 3.5 3.5 3.5 201-250 0.27-0.30 150 2.0 2.0 2.0 2.5 2.5 2.5 141-200 0.25-0.29 125 1.5 1.5 1.5 1.5 2.0 2.0 105-140 0.22-0.28 100 1.0 1.0 1.0 1.5 1.5 1.5 DOMESTIC COLD WATER AND HORIZONTAL RAIN LEADERS TO FIRST VERTICAL RAIN LEADER 40-60 0.22-0.28 100 0.5 0.5 0.5 0.5 ' 0.5 0.5 COOLING SYSTEMS (CHILLED WATER, BRINE AND REFRIGERANT, WATERSIDE ECONOMIZER SYSTEMS)** 40-60 0.22-0.28 100 1.0 1.0 1.0 1.5 1.5 1.5 <40 0.22-0.28 100 1.0 1.0 1.5 1.5 1.5 2.0 * NOT REQUIRED FOR <1-1/4" HEATING PIPE BETWEEN CONTROL VALVE & COIL, IF <4 FEET FROM COIL ** TYPICAL CONDENSER WATER PIPE IN NON -ECONOMIZER SYSTEMS DOES NOT REQUIRE INSULATION ***CHILLED WATER PIPING TO BE INSULATED WITH 2" THICK ARMAFLEX CLOSED CELL INSULATION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION M0.00 1 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC M0.01 SCHEDULES SHEET - HVAC M2.01A PARTIAL 1ST FLOOR PLAN A - HVAC M2.01 C PARTIAL 1ST FLOOR PLAN C - HVAC M2.R1A PARTIAL ROOF PLAN A - HVAC M5.01 UPS ROOM NORTH WALL - HVAC REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 9 2013 Hermanson APN NUMBER 102304-9081 Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ City of Ila BUILDING DIVISION f LEGAL DESCRIPTION SAB EY -TE LX PROJECT HAWK LOT 4 OF TUKWILA BLA L02-057 REC #20030327900002 LOCATED IN SE 1/4 OF SEC 9 & SW 1/4 10 IN 23-04 3433 SOUTH 120TH PLACE. TUKWILA, WA 98168 places editor ,glesea - Revisions VICINITY MAP NO SCALE ed 03/15/13 MG PERMIT 02/20/13 MG COORD SET No. Date By Description Design Team Design Drawn Checked DN SITE MAP NO SCALE Scale AS NOTED Project Number 10-13-01762 Drawing Number Issue Date 02/20/13 D-0170-01762 FILE COPA Plan review approval is to and► Approval of construction documents #h not authorize the v o!ation of any code or ordinanceReceipt of approved Field Copy and By Date 1 zi 13 City Of Tukwila BUILDING DIVISION 1111;:,� RECEIVED CITY OF TUKWILA MAR 19 2013 PERMIT CENTER M1?r0'1 ISSUE FOR PERMIT LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC 1 LLI-l.I. R1L,P1L l.V1V 1 rv-w.. 1 Vit. 1 V rltV vt�lc J�,L.rc r .0 1 Cl, l 1VtV. t -VK CllUll'I�I�IV I . s KL U1KI L tiY NA I l:ONAL ELEC i RICAL CODE. MANUFACTURER TO PROVIDE SCCR LISTING (14 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 2 PROVIDE CHILLER OPERATION TO OF DB 3 MANUFACTURER TO PROVIDE MULTIPLE REFRIGERATION CIRCUITS WITH VFD ON SCREW COMPRESSORS AND A TURNDOWN CAPABILITY OF 10% 4 PROVIDE HIGH AMBIENT CONTROL 5 PROVIDE 0.95 POWER FACTOR ACROSS ALL OPERATING CONDITIONS AND 0 INRUSH CURRENT- VFD WILL SOFT -START COMPRESSORS COMPUTER ROOM AIR HANDLING LAST UPDATED: UNIT TAG INDOOR UNIT 03/12/13 CRAH-101 CRAH-201 CRAH-301 CRAH-401 LOCATION / SERVES CRAH-501 TO 507 CRAH-601 TO 608 SUITE 1 BASIS OF DESIGN SUITE 2 SUITE 3 FUTURE SUPPLY CFM ESP IN WG EAT°F DB WB LAT°F EVAPORATOR MBH DB WB TOTAL SENS. MOTOR BHP TOTAL MOTOR HP FLUID EWT GPM 24,000 0.2 85.0 62.0 65.0 461.0 461.0 13.44 20.00 20% PG 55 SUITE 4 SUITE 5 SUITE 6 FUTURE FUTURE FUTURE 24,000 24,000 LIEBERT CW -181 LIEBERT CW -181 24,000 24,000 24,000 0.2 0.2 0.2 0.2 0.2 85.0 62.0 65.0 461.0 461.0 13.44 20.00 20% PG 55 69 - 69 WPD (FT) 7.1 EMERGENCY POWER ELECTRICAL REQUIRED YES OPTIONAL MCA MOCP V/PH WEIGHT LBS REMARKS 16.9 20.0 460/3 1-10 7.1 YES 16.9 20.0 85.0 85.0 85.0 85.0 62.0 62.0 62.0 62.0 65.0 461.0 461.0 13.44 20.00 20% PG 55 69 7.1 YES 16.9 20.0 65.0 65.0 65.0 461.0 461.0 13.44 20.00 20% PG 55 69 7.1 YES 16.9 20.0 461.0 461.0 13.44 20.00 20% PG 55 69 7.1. YES 16.9 20.0 461.0 461.0 13.44 20.00 20% PG 55 69 7.1 YES 16.9 20.0 460/3 460/3 460/3 460/3 460/3 1-10 1-10 2,500 2,500 1-10 1-10 1-10 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTEC.1 ION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE. MANUFACTURER TO PROVIDE SCCR LISTING (65 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. DOWNFLOW CONFIGURATION WITH (QTY 3) DROP DOWN PLENUM SUPPLY FANS, DUAL -FLOAT CONDENSATE PUMP WITH DUAL LOCKING DISCONNECTS FOR UNIT SHUTDOWN, 2 -WAY CONTROL VALVE, 30"HIGH SEISMIC RATED FLOOR STAND. 3 UNIT CONTROLS TO BE ICOM LARGE DISPLAY COMPLETE WITH BAC -NET CONTROLLER. 4 SMOKE SENSOR INSTALLED WITHIN UNIT AND LEAK DETECTOR SHIPPED LOOSE FOR LOCATION BELOW UNIT. 5 4" MERV FILTERS 6 18" HIGH FACTORY FILTER PLENUM, HERMANSON TO EXTEND RETURN AIR INLET TO BE A MINIMUM 10' ABOVE RAISED FLOOR 7 EXTRA TERMINALS FOR REMOTE SHUTDOWN 8 EXTRA COMMON ALARM CONTACTS 9 NEW CRAH UNITS ARE A HIGHER EFFICIENCY THAN EXISTING UNITS, BUILDING COMPONENTS DO NOT HAVE THE CAPABILITY TO SUP[PORT AN AIR ECONOMIZER SYSTEM. AIR COOLED CHILLER SCHEDULE LAST UPDATED: 03/12/13 UNIT TAG LOCATION SERVES BASIS OF DESIGN NOM. TONS CHILLED WATER NPLV (EER) ELECTRICAL WEIGHT LBS REMARKS GPM PD FT EWT °F LWT °F MCA V/PH CH -101 MECH YARD SERVER ROOMS FUTURE 420 1,500 0.50 0.32 0.50 120/1 76 65 1-6 EF -R02 CH -102 MECH YARD SERVER ROOMS FUTURE 420 0.50 0.32 0.50 120/1 76 65 1-6 CH -103 MECH YARD SERVER ROOMS FUTURE 420 CH -104 MECH YARD SERVER ROOMS FUTURE 420 CH -105 MECH YARD SERVER ROOMS YORK-YVAA 420 672 11.8 70 55 22.50 595 460/3 22,000 1,2,3,4,5 CH -106 MECH YARD SERVER ROOMS YORK-YVAA 420 672 11.8 70 55 2250 595 460/3 22,000 1,2,3,4,5 1 LLI-l.I. R1L,P1L l.V1V 1 rv-w.. 1 Vit. 1 V rltV vt�lc J�,L.rc r .0 1 Cl, l 1VtV. t -VK CllUll'I�I�IV I . s KL U1KI L tiY NA I l:ONAL ELEC i RICAL CODE. MANUFACTURER TO PROVIDE SCCR LISTING (14 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. 2 PROVIDE CHILLER OPERATION TO OF DB 3 MANUFACTURER TO PROVIDE MULTIPLE REFRIGERATION CIRCUITS WITH VFD ON SCREW COMPRESSORS AND A TURNDOWN CAPABILITY OF 10% 4 PROVIDE HIGH AMBIENT CONTROL 5 PROVIDE 0.95 POWER FACTOR ACROSS ALL OPERATING CONDITIONS AND 0 INRUSH CURRENT- VFD WILL SOFT -START COMPRESSORS COMPUTER ROOM AIR HANDLING LAST UPDATED: UNIT TAG INDOOR UNIT 03/12/13 CRAH-101 CRAH-201 CRAH-301 CRAH-401 LOCATION / SERVES CRAH-501 TO 507 CRAH-601 TO 608 SUITE 1 BASIS OF DESIGN SUITE 2 SUITE 3 FUTURE SUPPLY CFM ESP IN WG EAT°F DB WB LAT°F EVAPORATOR MBH DB WB TOTAL SENS. MOTOR BHP TOTAL MOTOR HP FLUID EWT GPM 24,000 0.2 85.0 62.0 65.0 461.0 461.0 13.44 20.00 20% PG 55 SUITE 4 SUITE 5 SUITE 6 FUTURE FUTURE FUTURE 24,000 24,000 LIEBERT CW -181 LIEBERT CW -181 24,000 24,000 24,000 0.2 0.2 0.2 0.2 0.2 85.0 62.0 65.0 461.0 461.0 13.44 20.00 20% PG 55 69 - 69 WPD (FT) 7.1 EMERGENCY POWER ELECTRICAL REQUIRED YES OPTIONAL MCA MOCP V/PH WEIGHT LBS REMARKS 16.9 20.0 460/3 1-10 7.1 YES 16.9 20.0 85.0 85.0 85.0 85.0 62.0 62.0 62.0 62.0 65.0 461.0 461.0 13.44 20.00 20% PG 55 69 7.1 YES 16.9 20.0 65.0 65.0 65.0 461.0 461.0 13.44 20.00 20% PG 55 69 7.1 YES 16.9 20.0 461.0 461.0 13.44 20.00 20% PG 55 69 7.1. YES 16.9 20.0 461.0 461.0 13.44 20.00 20% PG 55 69 7.1 YES 16.9 20.0 460/3 460/3 460/3 460/3 460/3 1-10 1-10 2,500 2,500 1-10 1-10 1-10 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTEC.1 ION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE. MANUFACTURER TO PROVIDE SCCR LISTING (65 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. DOWNFLOW CONFIGURATION WITH (QTY 3) DROP DOWN PLENUM SUPPLY FANS, DUAL -FLOAT CONDENSATE PUMP WITH DUAL LOCKING DISCONNECTS FOR UNIT SHUTDOWN, 2 -WAY CONTROL VALVE, 30"HIGH SEISMIC RATED FLOOR STAND. 3 UNIT CONTROLS TO BE ICOM LARGE DISPLAY COMPLETE WITH BAC -NET CONTROLLER. 4 SMOKE SENSOR INSTALLED WITHIN UNIT AND LEAK DETECTOR SHIPPED LOOSE FOR LOCATION BELOW UNIT. 5 4" MERV FILTERS 6 18" HIGH FACTORY FILTER PLENUM, HERMANSON TO EXTEND RETURN AIR INLET TO BE A MINIMUM 10' ABOVE RAISED FLOOR 7 EXTRA TERMINALS FOR REMOTE SHUTDOWN 8 EXTRA COMMON ALARM CONTACTS 9 NEW CRAH UNITS ARE A HIGHER EFFICIENCY THAN EXISTING UNITS, BUILDING COMPONENTS DO NOT HAVE THE CAPABILITY TO SUP[PORT AN AIR ECONOMIZER SYSTEM. 3 4 5 6 EMERGENCY POWER BY ELECTRICAL CONTRACTOR, ALARM MODE CONTROL BY FIRE ALARM/ELECTRICAL CONTRACTOR BIRDSCREEN AND ROOF CURB MOTORIZED DAMPER EXPLOSION PROOF CONSTRUCTION FAN TO OPERATE CONTINUOUSLY UNIT TAG AIR HANDLING UNIT SCHEDULE AHU-101 LOCATION AHU-102 AHU-103 COLO -1 COLO -1 FUTURE SERVES UPS ROOM BASIS OF DESIGN INDOOR TEMP °F TRANE CSAA035UA DB UPS ROOM FUTURE GENERAL ;INDOOR TEMPERATURES AT 75°F/##°F 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE. MANUFACTURER TO PROVIDE SCCR LISTING (65 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. FOR UNITS WITH SHIPPING SPLITS ...._ ..._ SECTION TO SECTION FIELD ELECTRICAL CONNECTIONS TO BE BY ELECTRICAL CONTRACTOR STANDBY POWER REQUIRED TO BE PROVIDED BY THE ELECTRICAL SUBCONTRACTOR _...w..... PROVIDE _.._.. __...._,.__ _..._.�._...._�..__� .. _.___ _._ ..__�..._....w_. WITH CHILLED �.... ........... �_..m..w_ ___......_ .__r__ C WATER COOLING COIL, DOUBLE WALL CABINET CONSTRUCTION, PLUG SUPPLY FANS WITH VERTICAL DISCHARGE ANTI -MICROBIAL TREATED CONDENSATE u__...._ _.._._._ ..�..._...V.� m.._..� SATE PANS MERV 13 FILTERS VOLUME FAN CONTROL ..:. .._..�_ _...�... _....�. .:,....._: �...,....__..� ..,__ .._._:. _.._.....:....�..,�. .:_...._, ...M., .....:. �._..,.r.r.....,..__.. O U CO 0 WITH VFD. :PROVIDE SMOKE DETECTOR IN RETURN AIR PLENUM ....�. .._.._... ..... .... ... �....._......._.._._ NEW AHU'S AREA PART OF THE HIGH EFFICIENCY CHILLED WATER SYSTEM WHICH REPLACES THE OLDER STYLE CRAH UNITS, EXISTING CRAH UNITS DO NOT HAVE AN AIR ECONOMIZER SYSTEM. TRANE CSAA035UA 75 75 WB 61 61 EAT °F DB WB 82 82 61 61 MIN SAT DB 57 SUPPLY CFM 57 16,000 16,000 OSA CFM 0 0 ESP IN WG CHILLED WATER COOLING COIL FILTERS EWT °F LWT °F GPM PD FT HD AIR PD IN. W.G. TOTAL MBH SENS. MBH VELOCITY FPM AIR PD IN.W.G. ENDOOR FAN: 1.00 1.00 55 55 66.5 80 13.5 0.98 439 439 430 1 QTY 1 BHP ELEC LAST HP MCA 13.9 20 26.5 66.5 80 13.5 0.98 439 439 430 1 1 13.9 20 26.5 V/PH 480/3 480/3 UPDATED: 03/12/13 WEIGHT LBS 4,400 4,400 1 REMARKS 1 THRU 6 1 THRU 6 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 9 2013 City of Tukwila BUILDING DIVISION M.13-057 RECEIVED CITY OF TUKWILA MAR 19 2013 PERMIT CENTER ISSUE FOR PERMIT r 4 ermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL005BJ SAB EY -TE LX PROJECT HAWK 3433 SOUTH 120TH PLACE TUKWILA, WA 98168 9 FAN SCHEDULE LAST UPDATED: 03/12/13 UNIT TAG LOCATION SERVES BASIS OF DESIGN TYPE CFM ESP IN WG MOTOR ELECTRICAL LWA WEIGHT LBS REMARKS BHP HP/W V/PH EF -R01 ROOF UPS GREENHECK GB -121 DOMEX 1,500 0.50 0.32 0.50 120/1 76 65 1-6 EF -R02 FUTURE UPS GREENHECK GB -121 DOMEX 1,500 0.50 0.32 0.50 120/1 76 65 1-6 3 4 5 6 EMERGENCY POWER BY ELECTRICAL CONTRACTOR, ALARM MODE CONTROL BY FIRE ALARM/ELECTRICAL CONTRACTOR BIRDSCREEN AND ROOF CURB MOTORIZED DAMPER EXPLOSION PROOF CONSTRUCTION FAN TO OPERATE CONTINUOUSLY UNIT TAG AIR HANDLING UNIT SCHEDULE AHU-101 LOCATION AHU-102 AHU-103 COLO -1 COLO -1 FUTURE SERVES UPS ROOM BASIS OF DESIGN INDOOR TEMP °F TRANE CSAA035UA DB UPS ROOM FUTURE GENERAL ;INDOOR TEMPERATURES AT 75°F/##°F 1 ELECTRICAL CONTRACTOR TO PROVIDE SCCR PROTECTION FOR EQUIPMENT AS REQUIRED BY NATIONAL ELECTRICAL CODE. MANUFACTURER TO PROVIDE SCCR LISTING (65 KAIC MINIMUM) INSIDE CONTROL PANEL AS REQUIRED BY NATIONAL ELECTRICAL CODE. FOR UNITS WITH SHIPPING SPLITS ...._ ..._ SECTION TO SECTION FIELD ELECTRICAL CONNECTIONS TO BE BY ELECTRICAL CONTRACTOR STANDBY POWER REQUIRED TO BE PROVIDED BY THE ELECTRICAL SUBCONTRACTOR _...w..... PROVIDE _.._.. __...._,.__ _..._.�._...._�..__� .. _.___ _._ ..__�..._....w_. WITH CHILLED �.... ........... �_..m..w_ ___......_ .__r__ C WATER COOLING COIL, DOUBLE WALL CABINET CONSTRUCTION, PLUG SUPPLY FANS WITH VERTICAL DISCHARGE ANTI -MICROBIAL TREATED CONDENSATE u__...._ _.._._._ ..�..._...V.� m.._..� SATE PANS MERV 13 FILTERS VOLUME FAN CONTROL ..:. .._..�_ _...�... _....�. .:,....._: �...,....__..� ..,__ .._._:. _.._.....:....�..,�. .:_...._, ...M., .....:. �._..,.r.r.....,..__.. O U CO 0 WITH VFD. :PROVIDE SMOKE DETECTOR IN RETURN AIR PLENUM ....�. .._.._... ..... .... ... �....._......._.._._ NEW AHU'S AREA PART OF THE HIGH EFFICIENCY CHILLED WATER SYSTEM WHICH REPLACES THE OLDER STYLE CRAH UNITS, EXISTING CRAH UNITS DO NOT HAVE AN AIR ECONOMIZER SYSTEM. TRANE CSAA035UA 75 75 WB 61 61 EAT °F DB WB 82 82 61 61 MIN SAT DB 57 SUPPLY CFM 57 16,000 16,000 OSA CFM 0 0 ESP IN WG CHILLED WATER COOLING COIL FILTERS EWT °F LWT °F GPM PD FT HD AIR PD IN. W.G. TOTAL MBH SENS. MBH VELOCITY FPM AIR PD IN.W.G. ENDOOR FAN: 1.00 1.00 55 55 66.5 80 13.5 0.98 439 439 430 1 QTY 1 BHP ELEC LAST HP MCA 13.9 20 26.5 66.5 80 13.5 0.98 439 439 430 1 1 13.9 20 26.5 V/PH 480/3 480/3 UPDATED: 03/12/13 WEIGHT LBS 4,400 4,400 1 REMARKS 1 THRU 6 1 THRU 6 REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 9 2013 City of Tukwila BUILDING DIVISION M.13-057 RECEIVED CITY OF TUKWILA MAR 19 2013 PERMIT CENTER ISSUE FOR PERMIT r 4 ermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL005BJ SAB EY -TE LX PROJECT HAWK 3433 SOUTH 120TH PLACE TUKWILA, WA 98168 og t- i 0 96149 13T ��� NAL Revisions 03/15/13 MG PERMIT 02/20/13 MG COORD SET No. Date By Description Design Team Design MG Drawn ER Checked DN Scale AS NOTED Project Number 10-13-01762 Drawing Number D-0170-01762 Issue Date 02/20/13 SCHEDULES & DETAILS SHEET - HVAC B e% A A rAz r"' 77 D 10 ,00, 0,22 000' 9 RELOCATE F0-1 TO NEW NOp ROOM (PH -1) EXTEND REFER LINES FROM EXIST. CU -1 OUTDOOR UN PIPE CONDENSATE TO NEAREST FLOOR 46X22 SU I TITUS MC (r(P) 5333 -0" 44X48 EXPANDED METAL RA G LLE (P -1) CCHWS & CHWR '111 (BELOW RAISED FLOOR).. " 4"CHW 4"CHW 8'X4' TRL SFE GRILLE - EXPANDED ETAL (SHOP PAINT TO ATCH WALLe1 e r: 7N ; 00 8'X4'TRANSFR GRILLE (CAP THIS SIDE AHU-102 (PH -1) PARALLEL BLADE DAMPER & END CAP CAP VERTICAL/DR FOR FUTURE AHL (8' ABOVE RAISE RA GRILLE OP D FLO AHU -103 1 I I (FuTuRE-PII-2) —4 6)(22 W — — L NOTE: UPS ROOM CONTROL MONITORING PROVIDED BY CONTROLS CONTRACTOR THERMOSTAT & PRESSURE SENSORS ARE NOT SHOWN, REFER TO CONTROLS CONTRACTOR SEQUENCE OF OPERATION & DRAWINGS X22 SUPPLY GRILLE CAP FOR FUTURE (PH -2) rEWEDVR CODE COMPLANCE APPROVED APR 2013 FUTURE MOTORIZED PER (PH -2) 6X22 W ..... City of Tuklivila BUILDING DIVISION 7 6 5 --057 40"0 W (PH -2) SUPPLY AIR DUCT TO ABOVE 14' HIGH CEILliG.__ 1,000 co.% s.to. r L. ,:gmg A', 17-0") [ I I RECEIVED CITY OF TUKWILA MAR 1 9 2013 PERMIT CENTER 0-1 PARTIAL 1ST FLOOR PLAN A — HVAC r‘ SCALE: 1/8" = 1'—O SCALE: '81"---1 1 3' 5' 10' 15' 25' 2' 4' EY PLAN ISSUE FOR PERMIT Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ SABEY-TELX PROJECT HAWK 3433 SOUTH 120TH PLACE TUKWILA, WA 98168 Revisions 03/15/13 MG PERMIT 02/20/13 MG COORD SET No. Date By Description Design Design Team MG Drawn ER Checked DN Scale AS NOTED Project Number 10-13-01762 Drawing Number D-0170-01762 Issue Date 02/20/13 PARTIAL IST FLOOR PLANA - HVAC M2.01A J K 45 o EFTETWED FOR CODE COMPLIANCE APPROVED APR 0 9 2013 City of Tukwila BUILDING DIVISION NOTE: CONTROL MONITORING PROVIDED BY CONTROLS CONTRACTOR THERMOSTAT PRESSURE SENSORS ARE NOT SHOWN, REFER TO CONTROLS CONTRACTOR SEQUENCE OF OPERATION & DRAWINGS CRAH-601 0 CRAH 602 ° CRAH-604 6" COND. PIPING EXTENDS TO NEW CHILLER CONNECTIONS, PROVIDE 2" ARMAFLEX CLOSED CELL INSULATION & ALUMINUM COVER AT NEW PIPING. EXTEND EXISTING 22" CHWS/CHWR PIPING AND CONNECT TO NEW CRAH UNIT. INSULATE PIPE WITH INSULATION SAME AS EXISTING SYSTEM (ARMAFLEX CLOSED CELL). (TYP. COLO 5 & 6) CONNECT UNIT CONDENSATE TO EXISTING R CONDENSATE PIPING i 4 3 VU3O57 0 CRAH-501 ° CRAH-506 2 RECEIVED CITY OF TUKWILA MAR 1 9 2013 \ PERMIT CENTER PROVIDE ADDITIONAL RETURN AIR PLENUM TO TOP OF UNITS TO MIN. HEIGHT OF 10' ABOVE RAISED FLOOR. (TYP. COLO 5 & 6) A KEY KLAN SIiE1FOR PERMIT PARTIAL 1ST FLOOR PLAN C SCALE: 1/8" = 1'-0" E ermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ SABEY-TE LX PROJECT HAWK 3433 SOUTH 120TH PLACE TUKWILA, WA 98168 A a • • DO)? i,° &., , - 98149 1ST ZONAL #� Revisions 03/15/13 MG PERMIT 02/20/13 MG COORD SET No. Date By Description Design Team Design MG Drawn ER Checked DN Scale AS NOTED Project Number 10-13-01762 Drawing Number D-0170-01762 Issue Date 02/20/13 PARTIAL 1ST FLOOR PLAN C - HVAC M2.O1C �T i 3 99 / _99 Lov A -R ID R_� \T TM S= 99 D\ NEW EF R1 (PH -1) ROOF CAP OVER EXIS ROOF CURB. (P REMOVE EXIST. EF CAP AT ROOF CURB. (PH -1) REVIEW© FOR CODE COMPLIANCE' APPROVED APR 0 9 2013 INSTALL NEW ROOF CURB AND DUCT INTO FUTURE UPS ROOM CAP FOR FUTURE FAN (PH -1 4 SCALE: a"H' KEY PLAN 2' 4' 0' 15' 25' RECEIVED CITY OF TUKWILA MAR 19 2013 PERMIT CENTER. ISSUE FOR PERMIT ermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ SAB EY -TE LX PROJECT HAWK 3433 SOUTH 120TH PLACE TUKWILA, WA 98168 a co it, ir, % J 3814.9' jONAL Revisions 03/15/13 MG PERMIT 02/20/13 MG COORD SET No. Date By Description Design Team Design MG Drawn ER Checked DN Scale AS NOTED Project Number 10-13-01762 Drawing Number D-0170-01762 Issue Date 02/20/13 PARTIAL ROOF PLAN A - HVAC M2.RIA 44X48 RETURN GRILLE 46X22 SUPPLY GRILLE 5'- 18' 26'-6" 1 1 16'-6" 22'- 11 FUTURE (PH -2) II GYPSUM BOARD ON �� II UNDERSIDE OF STRUCTURE 11 COLO SUITE CEILING 11 II II II II UPS CONCRETE FLOOR COLO SUITE RAISED FLOOR COLO SUITE CONCRETE FLOOR UPS ROOM NORTH WALL - HVAC SCALE: 1/8" = RE4IEW'ED FOR CODE COMPLIANCE APPROVED APR 0 9 2013 City of Tukwila BUILDING DIVISION SCALE: a"=1 15' 25' 2' 4' RECEIVED CITY OF TUKWILA MAR 1 9 2013 PERMIT CENTER ISSUE FOR PERMIT :,,„ ermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ SAB EY -TE LX PROJECT HAWK 3433 SOUTH 120TH PLACE TUKWILA, WA 98168 • DO o co � z �t 98149 o NAL Revisions 03/15/13 MG PERMIT 02/20/13 MG COORD SET No. Date By Description Design Team Design MG Drawn ER Checked DN Scale AS NOTED Project Number 10-13-01762 Drawing Number D-0170-01762 Issue Date 02/20/13 UPS ROOM NORTH WALL - HVAC M5.O1