Loading...
HomeMy WebLinkAboutPermit M13-058 - ORKIN - REPLACE ROOF TOP UNITORKIN 925 INDUSTRY DR M13-058 City Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 2523049034 Address: 925 INDUSTRY DR TUKW Project Name: ORKIN Permit Number: M13-058 Issue Date: 04/11/2013 Permit Expires On: 10/08/2013 Owner: Name: WALTON CWWA TUKWILA 1 LLC Address: C/O CTMT - WALTON RE TAX , 4678 WORLD PARKWAY CIR 63134 Contact Person: Name: JOFFRE SECHIER Address: 3202 C ST NE , AUBURN WA 98002 Email: JOFFRE@COMFORTMECH.COM Contractor: Name: COMFORT MECHANICAL INC Address: 6617 S 193 PL, #P-105 , KENT, WA 98032 Contractor License No: COMFOMI015LA Phone: 425 251-9840 Phone: 425-251-9840 Expiration Date: 04/25/2014 DESCRIPTION OF WORK: REPLACE (1) EXISTING 5 -TON ELECTRIC ROOFTOP UNIT WITH NEW 5 -TON PACKAGED HEAT PUMP. Value of Mechanical: $5,550.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $257.06 International Mechanical Code Edition: 2009 t'6A•1 �IXJC Date: ot-titib I hereby certify that I have read and = amin d this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, hether specified herein or not. The granting of this permit does not pre u - to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the erfoijcn4nce of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: 4 u /i This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. IAI') AMC' Drin+crl• nd_11_9n1R PERMIT CONDITIONS Permit No. M13-058 1: ***BUILDING DEPARTMENT CONDTfIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-058 Printed: 04-11-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila. 1V4 98188 http://www.TukwilaWA.Rov Mechanical Permit No. Project. No. t 3 Date Application Accepted CPA 20 � . Date Application Expires MATO (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 2523049034 Site Address: 925 INDUSTRY DRIVE Suite Number: Floor: Tenant Name: ORKIN PROPERTY OWNER Name: JOFFRE SECHIER Name: CWWA TUKWILA 1 LLC City: AUBURN State: WA Zip: 98002 Address: 825 INDUSTRY DR Zip: 98002 City: TUKWILA- State: WA Zip: 98188 CONTACT PERSON - person receiving all project ,:.. . communication Name: JOFFRE SECHIER Address: 3202 C ST NE City: AUBURN State: WA Zip: 98002 City: AUBURN State: WA Zip: 98002 Phone: (425) 251-9840 Fax: (253) 736-6598 Email: joffre@comfortmech.com New Tenant: ❑ Yes m..No MECHANICAL CONTRACTOR INFORMATION Company Name: COMFORT MECHANICAL Address: 3202 C ST NE City: AUBURN State: WA Zip: 98002 Phone: (425) 251-9840 Fax: (253) 736-6598 Contr Reg No.: COMFOMI015LA Exp Date: 04/25/2014 Tukwila Business License No.: BUS -0993365 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: REPLACE (1) EXISTING 5 -TON ELECTRIC/ELECTRIC ROOFTOP UNIT WITH NEW 5 -TON PACKAGED HEAT PUMP. 5,550 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric m Gas Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9.1 I.docx Revised: August 2011 bh Page 1 of 2 indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system 1 Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic 1 Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment 1 Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/I,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION. NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF P RJU Y tY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 1 E' 1.' AUTHORIZED AGENT: Signature: Date: 03/20/2013 Print Name: I 'a F ''►ECHIER Day Telephone: (425) 251-9840 Mailing Address: 3202 C ST NE AUBURN WA 98002 City State Zip F1:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-I I.docx Revised: August 2011 bh Page 2 of 2 r City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2523049034 Address: 925 INDUSTRY DR TUKW Suite No: Applicant: ORKIN RECEIPT Permit Number: M13-058 Status: PENDING Applied Date: 03/20/2013 Issue Date: Receipt No.: R13-01091 Payment Amount: $257.06 Initials: JEM Payment Date: 03/20/2013 11:36 AM User ID: 1165 Balance: $0.00 Payee: JOFFRE T SECHIER, COMFORT MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 310253 ACCOUNT ITEM LIST: Description 257.06 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 205.65 000.345.830 51.41 Total: $257.06 .Inn• Dnnninl_rla Printarl• n3 -9n -9n13 FINSPECTION RECORD etain a copy with permit INSPEC110'N NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 piis_ 0-sE Project: 0R1{LN Type of Inspection: riz Awl -7W C., -- C -73 -...Ni A L._ Address: Ste. _ gym. ttS i P 4 ..fl2- Date Called: Special Instructions: Date Wanted:. _a.m� . Requester: Phone No: aocs-% 3 3 8 Z . ''Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: i t iii -)014-1-1 .,y i b /----/ /-7,4, 4 / .s....1) :0- 1 N r Inspect � Date: 2 ' :3/tem nAAA, jui/l! / (� l n REIN PS ECTION FEE REQUIRED. rior to net inspection. fee mus e e/d/ait 6300 Southcenter Blvd.. Suite 100,Call to schedule reinspection. i INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF T.UKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 �, (206).431-3670 Permit Inspection Request Line (206) 431-2451 M13-0,.5° Project: 0Ril-.-tki Type of Inspection: i S•A 0 R17/ 7: J --7)'.,m — k)J,2/'/P Address: ( `i 2S ...tu'.l( � it....✓ Date Called: • Special Instructions: — 1.4 Date Wanted:. C , arm: Requester: -� D • s • ,-Sr.7"/, PhoneNo: --fid 4/4/41/ JApproved per applicable codes. Corrections required prior to approval. COMMENTS: i.r 0 R17/ 7: J --7)'.,m — k)J,2/'/P ...!., Re-ir1 5 ,,,,, A7 ►o..., —- ' � Njei i , 5 (. – iv!, 7) p,P6_ f N SLrL4 -/, tS & _ ///,`z/ 5-- A r b (7�2vs3 00.4)4/ 77 D • s • ,-Sr.7"/, 5 --fid 4/4/41/ Inspect f: 1 roVA t-(il 1 )L4 r1/11EI1SPECTION FEE REQUIRE. Prior to ne inspection, feemustbe' i,Paid at 6300 Southcenter Blvd. Suite 100. all to schedule reinspection. Project: Kidder -Mathews -5T Commercial PHP Prepared By: 5T Pkg HP 03/13/2013 12:57PM REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 9 2013 City of Tukwila BUILDING DIVISION A�- 5T Pkg HP PZZE e4 �� COPY Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet RECEIVED CITY OF TUKWILA MAR 2 0 2013 PERMIT CENTER Packaged Rooftop Builder 1.34 Page 1 of 8 CO R-21-1 Unit Report For 5T Pkg HP Project: Kidder -Mathews -5T Commercial PHP 03/13/2013 Prepared By: 12:57PM Unit Parameters Unit Model. 50TCQA06A0A3-0A0A0 Unit Size. 06 (5 Tons) Volts -Phase -Hertz. 208-1-60 Heating Type. Heat Pump Duct Cfg• Horizontal Supply / Horizontal Return Standard One -Stage Cooling Refrigeration Coil Lines and Filters Condensate Drain Line Size. 3/4 Return Air Filter Type. Throwaway Return Air Filter Quantity. 4 Return Air Filter Size. 16 x 16 x 2 Unit Configuration Electric Drive X13 AI/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts (STD.) 5 -Year Compressor (std.) Dimensions (ft. In.) & Weight (Ib.)'** Unit Length. 6' 2.375" Unit Width. 3' 10.75" Unit Height 3' 5.375" — Total Operating Weight 660 Ib •** Weights and Dimensions are approximate. Weight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 50TCQA06A0A3-0A0A0 Rooftop Unit 1 Base Unit Electromechanical control, No intake or exhaust option None Accessories CRECOMZR024A02 Horizontal EconoMi$er IV with solid-state controller 1 Packaged Rooftop Builder 1.34 Page 2 of 8 Project: Kidder -Mathews -5T Commercial PHP Prepared By: Certified Drawing for 5T Pkg HP 03/13/2013 12:57PM 1 40 -ES: . [N 4163(06AIN 6(6580D1NE45(ON5 2 CENTER OF GRAVITY 3 .110 DIREC1(014 OF AER FLOW UNIT 301(0604 33 3/8 1847; 185/8 14723 501[0605 33 3/8 18411 147/8 (3111 50120006 41 3/8 111511 141/8 13171 50120607 41 3/8 110511 14 1/8 3311/ FILTER ACCESS PANEL (TOOL -LESS) • • CONP.• ACCESS ' PANEL ' CONDENSER COIL INDOOR COIL ACCESS PANEL CONDUIT SIZE USE BAC(( 2-5/8 1611 TIP CURB WIDTH CONDENSER C016 OPTIONAL FACTORY INSTALLED CONVENIENCE OUTLET 41 4-5/8 11181 ELECTRICAL DISCONNECT LOCATION 0 UNITED P2. 301 OM TECHNOLOGIES 1186161. If CARRIER 11847 18(1 30314-81 11 147 8x03111' Y C8811713 COM0110104 6133 (011 13 (03[1( 11 1l1010[¢p3 61143(n11(8xNMLA1FE x60M011110113sn :MM. 168((11881 081311(IrI 8611 811(81141 81(1108(1 p ICC[nIEC[ 01 6(1188(1. 1- 333/8 18481 ECONOMIZEN HOOD (OPTIONAL/ 16-(/8 11 91 19-1/2 (4941 F 3-3/l I 6951 46 3/4 111871 _EFT 12-1/4 (3121 SEE T4RU THE - BASE CHART • 25 TJ 66361 32 1/4 18161 25-5/8 ---•' 16521 RETURN AIR E ALT. . CONDENSATE DRAIN OPENING IN BASEPAM 16 14061 1 10-7/8 (2771 6.I/4 J1571 4- 11.3/4 14511 SUPPLY AIR l TOP 12-1/8 (3011 18-1/2 (4701 1 29-3/8 411 RETURN I AIR 11411 26-1/2 16731 f 3-3/8 OPTIONAL CONTROL BOX FACTORY ACCESS PANEL INSTALLED DISCONNECT I INDOOR BLOWER ACCESS .Roo HANDL 14 3/8 118881 FP,ONT HANDLE 1851 y 503331 AIR 11-318 6-178 CONNECTION SIZES A 1 3/8• (351 DIA FIELD POWER SUPPLY NILE 2' 1511 DIA POWER SUPPLY 660260UT 1 3/1' 1441 DIA GAUGE ACCESS PLUG D 17/8' 1221 DIA FIELD CONTROL WIRING HOLE f [ 3/l•-14 1171 CONDENSATE DRAIN 2 1/2 ' 1641 DIA POWER SUPPLY KNOCK -OUT TNRU-THE-BA E CHAR THESE HOLES REQUIRED FOR USE CRBTMPWR00IAD1 THREADED WIRE REO'D HOLE CONDUIT SIZE USE SIZES IMAX.1 W 1/2' ACC. 1/6' 122.21 X 1/2' 24V 1/8' 122.21 T • 3/4' 10011 POWER 1 1/8' 128.11 FOR 'THRU-THE-BASE AN' FA TORY OPTION. 7111(4G5 FOR ONLY R 6 1 ARE PROVIDED SELECT EITHER 3/4' OR 1/2' • FOR POWER. DEPENDING OM WIRE SIZE E STD. CONDENSATE DRAIN ' 25-1/8 16381 16-3/4 .-I RETURN 1211 AIR SUPPLY AIR ILTER OUTSIDE 14(8 31 /4-+ 314333' 1197] A(R RE10RN RIGHT AIR BAROMETRIC RELIEF FLOW 11([1 I HT[ 1 OF 2 103-10-C9 30[1(13[3 01-23-09 50TC0 04-07 SINGLE ZONE ELECTRIC HEAT POMP 48TA1501 501 818 5.0 Packaged Rooftop Builder 1.34 Page 3 of 8 (t') WY- 4-f-1 Project: Kidder -Mathews -5T Commercial PHP Prepared By: Certified Drawing for 5T Pkg HP 03/13/2013 12:57PM Uh]1 STD. UN11 WEIGHT CORNER i CORNER WEIGHT IA1 ; I8) CORNER 1 CORNER RIC) WEIGHT ID) REAM 1 C G. HEIGHT 1 190. KG. 195. KG. 1 LBS. KG. L85. NG. i LBS. 6G. X 1 2 501(0404 505 229 136 62 ' 130 59 117 53 '23 56 136 1/4 (9211122 1/8 15621 16 3/8 ;4161 502(0405 510 231 138 63 131 59 118 SA 124 56 136 135 1/4 19211;22 1/8 15621 16 1/2 14191 501(0606 590 258 159 72 146 66 131 62 149 68 5/8 19051'22 5/8 15151 20 1/8 1511) 501(0407 630 288 166 75 156 75 119 1 68 149 1 68 37 1/4 19461122 7/8 25621 20 3/4 15271 CORNER A I I 680IED 1 O. hoc 0101 TECH.OLOGIES Stt(WSE. n CARRIER um 1X11 0 )0/II1 ;1100 1R01*.11 00 GR:01 CCOGtl110N 0 0 10 00010010( %000 100 0011001 *00011;00 1X11 100 81;4;124 WA,604,1 0* *000 r[l0pf Gen*. 00.'110(04 01 1x000 01/01040 0* 0010.60"1! 0021101 0000n1P0 1001 00100 **N(( 01 4 406(7000( 01 *0411101, i CORNER B CORNER C : 000 FRONT 64021 I RATE . 2 or 2 1 03-10-09 sm(1Gsu 01-23-09 50TCO 04-07 SINGLE ZONE ELECTRIC HEAT PUMP 48TM501501 771 5.0 Packaged Rooftop Builder 1.34 Page 4 of 8 Performance Summary For 5T Pkg HP Project: Kidder -Mathews -5T Commercial PHP 03/13/2013 Prepared By: 12:57PM Part Number: 50TCQA06A0A3-0A0A0 ARI SEER: . .. 13.20 Base Unit Dimensions Unit Length' 74.4 in Unit Width. 46.8 in Unit Height 41.4 in Operating Weight Base Unit Weight 590 Ib Accessories Horizontal EconoMi$er IV with solid-state controller 70 Ib Total Operating Weight 660 Ib Unit Unit Voltage -Phase -Hertz' 208-1-60 Air Discharge. Horizontal Fan Drive Type. Direct Actual Airflow. 1970 CFM Site Altitude' 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB'80.0 F ................. Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy 31.44 BTU/Ib Evaporator Leaving Air DB. 58.0 F Evaporator Leaving Air WB. 57.2 F Evaporator Leaving Air Enthalpy. 24.54 BTU/Ib Gross Cooling Capacity. 61.13 MBH Gross Sensible Capacity 46.91 MBH Compressor Power Input 5.50 kW Coil Bypass Factor 0.203 Heating Performance Outdoor Ambient Temperature 47.0 F Entering Air Indoor Coil DB. 70.0 F Leaving Air Indoor Coil DB. 97.4 F Total Heating Capacity. 58.31 MBH Integrated Heating Capacity. 58.31 MBH Heating Power Input 4.67 kW HSPF 7.7 Supply Fan External Static Pressure. 0.60 in wg Options / Accessories Static Pressure EconoMi$erlV / EconoMi$er2. 0.12 in wg Total External Static. 0.72 in wg Fan RPM. 1200 Fan Power 1.00 BHP Fan Motor Size, hp' 1 NOTE:. Motor Speed Tap 2, Horz, Direct Drive Electrical Data (Before July 30, 2012) Minimum Voltage. 187 Maximum Voltage.253 ............... Compressor #1 RLA. 26.2 Compressor #1 LRA' 134 Outdoor Fan Motor Qty:.. __ . 1 Packaged Rooftop Builder 1.34 Page 5 of 8 Performance Summary For 5T Pkg HP Project: Kidder -Mathews -5T Commercial PHP 03/13/2013 Prepared By: 12:57PM Outdoor Fan FLA (ea). Indoor Fan Motor Type. Direct Drive Indoor Fan Motor FLA. 7.4 Power Supply MCA* 41.7 Power Supply MOCP (Fuse or HACR):. 60 Min. Unit Disconnect FLA. 40 Min. Unit Disconnect LRA. 145 Electrical Convenience Outlet None 1.5 Electrical Data (July 30, 2012 and Beyond) Indoor Fan Motor FLA' 7.4 Power Supply MCA. 42 Power Supply MOCP: .... 60 Disconnect Size FLA. 40 Disconnect Size LRA. 145 July 30th and beyond units can be identified by serial number 3112XXXXXXXXX and higher Control Panel SCCR: 5kA RMS at Rated Symmetrical Voltage Acoustics Sound Rating 80.0 db Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz NA NA 92.7 125 Hz NA NA 84.9 250 Hz NA NA 79.0 500 Hz NA NA 76.7 1000 Hz NA NA 73.8 2000 Hz NA NA 69.6 4000 Hz NA NA 66.4 8000 Hz NA NA 62.8 Advanced Acoustics Advanced Accoustics Parameters 1. Unit height above ground: 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction' 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Frequency, Hz 63 125 250 500 1k 2k 4k 8k Overall Sound Power Levels at Units Acoustic Center (Lw), dB 92.7 84.9 79.0 76.7 73.8 69.6 66.4 62.8 93.7 Lw A -Weighted Sound Power Levels at Units Acoustic Center (LwA), dBA 66.5 68.8 70.4 73.5 73.8 70.8 67.4 61.7 79.5 LwA Sound Pressure Levels at Distance Specified above (Lp), dB 60.3 52.5 46.6 44.3 41.4 37.2 34.0 30.4 61.3 Lp A -Weighted Sound Pressure Levels at Distance Specified above (LpA), dBA 34.1 36.4 38.0 41.1 41.4 38.4 35.0 29.3 47.1 LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed Packaged Rooftop Builder 1.34 Page 6 of 8 Performance Summary For 5T Pkg HP Project: Kidder -Mathews -5T Commercial PHP 03/13/2013 Prepared By: 12:57PM that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Packaged Rooftop Builder 1.34 Page 7 of 8 Unit Feature Sheet for 5T Pkg HP Project: Kidder -Mathews -5T Commercial PHP 03/13/2013 Prepared By: 12:57PM e Vl�eatherMakef- SOTCQ PACKAGED ROOFTOP HEAT PUMP UNITS 3, 4, 5, 6, 7-112, 8-112,10 and 12.5 TONS 50TCQunits are high -efficiency single -packaged heat pump units that are pre -wired and prechargedwith PURON (HFC) refrigerant. Electricheatis availableas a field -installed accessory. The units arefully fadorytestedand agency certified US Ai CFFl1tFIE0. lir rib •xPM*MIN iiis• made. moolkatarlp t•M•400o e. tl•at•rego W •mktheianclonvali. Certified to ISO 9001 PERFORMANCE FEATURES • PURON (R -410A) HFC refrigerant • ASHRAE.90.1 energy compliant • SEERsupto13.4.EERsupto 11 2 • IEER'supto 12.2 • HSPF's up to 1.7 and COP's up to 3 3 • Single stage cooing cap ear/ control on04-07 models • Two-stage cooling cap acdycontrol on 08 - 14 models • Exotusrve noncorrosive composite condensate pan an accordance with ASHRAE 62 Standard. sloping design: side or center dram • Field convertible from vemcal to honrontalanflow on as models. No specialke recurred on 04-12 models. Supply duct lit required for 14 size model only • Coppertube atuminumfn coils with optional corrosion resistant cods • Pre -painted extenorpanetsand primer ooated interior panetstested to 500 hours salt spray protection • Aoutmtru refrigerant metering system • Cooling operating range up to 115F (46C) and down to 25F (4C) • Solid-state control board and easy access terminal board • Refrigerant filter drier and accumulator on each refrigerant circuit • Fully insulated cabinet • Automatic changeoverwiien used with autochangeove:thermostat • Rated in accordance with AHRI Standards240 (04-06 saes) and 340 (07-14) • Dasigned in accordance with Underwviters" Laboratories Standard 1995 • Listed by UL and UL, Canada MAINTENANCE FEATURES: • Access panelsWith easy grip handles • Innovative, easy starling, no strip strew features on unit access panels. • Two-inch disposable return air filters • Toot4ess fitter access door • Belt drive evaporator -fan motor and pulley combinations available an at sizes to meet any application • Electric Drive x13 (5 speed/torque)motoron 04 to 06 models • Canneltennvnal board facilitating simple safety circuit troubleshooting and sunpkfred comml box arrangement iN STALLATION FEATURES: • Thmthe-bottampowerentrycapabiity standard • Single point eleddcconnedions • Full perimeter base rod with built-in rigging adapters and fork truck slots RELIABILITY FEATURES: • Scroll compressors with intemet linebreak overload protection • Dependable Time /Temperature defrost board and logic • 24-valtcontrol cicala protected with resettabtecucuitbreaker • Permanentlytubricated evaporator -fan motor • Totally endosedGond enserr motors With permanently lubricated bearings • Loss of charge, freeze protection, and high-pressure switches STANDARD WARRANTY: • 5-yesreiectric heaters • 5-yearcompressor • 1-yearparts Many optional warranties also available OPTION S INCLUDE BUTARE NOT UMITEDTO: • Multi Protocol (RTU Open)and PremierL ,kT• Med Digital Contro4ers • Non-fused disoonned switch • Economizer options forelectro-mechan-ncaland DDC control • Corrosion resistant cod options for evaporator and condenser • Option attndoorfen motors for expanded airfbwcapability • Accessory electric heat (field -in stalled option only) • Smoke detectors— Supply and Return as • lunged access panels Packaged Rooftop Builder 1.34 Page 8 of 8 SUBMITTAL FORM NO. 2502-11 P SUBMITTED TO COMPANY: DRAWN BY: JOB NAME: EQUIPMENT NOTES: M. HARGIS Horizontal economizer with built-in relief damper for Carrier 48150TC A/B04-A1B07; 50TCQ A04 -A07; 48/50TC A/D08,A09,A1D12,D14; 50TCQ D08 -D12; 48150HC A04-A07,D08-D12; 50HCQ A04-A07,D08-D09; 48/50TF,TM,HJ 004-014; 48150HE 003-005; 50TFQ 004-014; 5OHJQ 008-009 Units FEATURES: • Gear driven dampers, eliminates slippage associated with standard linkage. • Factory assembled hood. • Direct coupled actuator. • Low static pressure loss through economizer. • 100% barometric relief capability. • Top of hoods are sloped to allow for water run-off. • Hoods are constructed of pre paint steel, matching the finish of the HVAC unit. Water entrainment filter provided. Horizontal E onomizer ctuator Part Number: 0849 Series Carrier Units MIcroMeti Economizer No. Weight 48150TC A/B04 A/B07; 50TCO A04 -A07; 48/50HC A04 -A06; 50HCQ A04 -A06: 48/50TF,TM,HJ,TFQ 004007; 48/50HE 003-006 0849-0101 86 lbs 48/50TC A/D08A09,A/D12,014; 50TCQ 008-012; 48150HC A07, 008-012, 50HCQ A07,008-009; 48/50TF.TM,HJ 008-014; 50TFQ 008-014; 5OHJQ 008-009 0849-0201 135 lbs •; ECOnomRer includes• "<:. Honeywell W7212. - coirtrolier capable, of CO2,. ,; demand control and power exhaust control. Filter door 24 3/4" Static Pressure Drop through Dampers - In w.g. 0849-0101 0849.0201 CFM 1200 1600 2000 2400 2800 3000 3400 4000 5000 Return Air 0.055 0.088 0.14 0.22 0.11 0.14 0.17 0.25 0.38 Outside Air 0.024 0.043 0.073 0.098 0.10 0.11 0.15 0.20 0.31 Outside air / relief air hood 1. Return air test performed with outside air damper 100% closed. 2. Relief air and outside air test performed with retum air damper 100% closed. NOTE A: This horizontal blank off is shipped with the 0849-0201, but Is only used on the taller 8 1/2, 10, 12 1/2 ton units. NOTE B: This panel extender is shipped with the 0849-0201, but is only used on the taller 8 1/2, 10, 12 1/2 ton units. If using the 0849-0101 with the taller HJ007, the optional 0840-0100-FRBO panel must be ordered. THIS DOCUMENT IS THE PROPERTY OF MICROMETL CORPORATION AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE CONTENTS WILL NOT BE DISCLOSED OR USED WITHOUT MICROMETL'S WRITTEN CONSENT. MICROMETL 3035 NORTH SHADELAND AVENUE, SUITE 300 • INDIANAPOIJS, IN 45226 • 1.800.662-4822 •• MICROMETL WEST 202 SOUTH 18TH ST. • SPARKS, NV 89431 • 1.800.884-4862 ED FOR REVIEWMPLIANCE CODE DAPPROVED APR 0g 2013 City NGDila IVISION BUILD �� OF ‘,‘ \IN 4if-C-V3/7// WAsy GOO( zlrn4/, l Q' `�R�;99 �'�. 46. ` FGISTER7, �k,� v �6Z9/ONALEN z> _ _ NS EXPIRES 1p hzh3 D - STRUCTURAL CALCULATIONS Orkin RTU 925 Industry Drive Tukwila, Washington MARCH 18, 2013 PREPARED FOR: Comfort Mechanical 3202 C Street NE Auburn, Washington 98002 PREPARED BY: Moore Engineering Group 21902 96th Avenue SE Snohomish, Washington RECEIVED CITY OF TUKWILA MA2 2 3 20:3 PERMIT CENTER Moore Engineering Group M o� GENERAL STRUCTURAL NOTES: 1. ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THESE NOTES AND THE INTERNATIONAL BUILDING CODE (IBC), 2009 EDITION. 2. DESIGN LOADING CRITERIA: ROOF LIVE LOAD 25 PSF MECHANICAL UNIT 660 POUNDS EARTHQUAKE SDS = 0.912 SITE CLASS D to E WIND 85 MPH, EXPOSURE B 3. STRUCTURAL CALCULATIONS AND SKETCHES SHALL BE USED IN CONJUNCTION WITH MECHANICAL DRAWINGS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY ENGINEER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION. 4. CONTRACTOR SHALL VERIFY ALL EXISTING DIMENSIONS, MEMBER SIZES AND CONDITIONS PRIOR TO COMMENCING ANY WORK. ALL DIMENSIONS OF EXISTING CONSTRUCTION SHOWN ARE INTENDED AS GUIDELINES ONLY AND MUST BE VERIFIED. THE EXISTING CONDITIONS SHOWN ON THE SKETCHES ARE BASED EITHER ON SITE OBSERVATION, ORIGINAL DRAWINGS OR WERE ASSUMED BASED ON EXPECTED CONDITIONS. IF THE EXISTING CONDITIONS DO NOT CLOSELY MATCH THE CONDITIONS SHOWN ON THE SKETCHES, OR IF THE EXISTING MATERIALS ARE OF QUESTIONABLE OR SUBSTANDARD QUALITY, NOTIFY THE ENGINEER PRIOR TO COMMENCING ANY WORK. 5. CONTRACTOR SHALL PROVIDE TEMPORARY BRACING FOR THE STRUCTURE AND STRUCTURAL COMPONENTS UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS. 6. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL SAFETY PRECAUTIONS AND THE METHODS, TECHNIQUES, SEQUENCES OR PROCEDURES REQUIRED FOR THE COMPLETION OF THE WORK. 7. FRAMING LUMBER SHALL BE KILN DRIED OR MC -19, AND GRADED AND MARKED IN CONFORMANCE WITH W.C.L.B. STANDARD GRADING RULES FOR WEST COAST LUMBER NO. 17. FURNISH TO THE FOLLOWING MINIMUM STANDARDS: JOISTS: (4x MEMBERS) HEM -FIR NO. 1 Fb = 975 PSI, Fv = 150 PSI 8. TIMBER CONNECTORS CALLED OUT BY LETTERS AND NUMBERS SHALL BE "STRONG - TIE" BY SIMPSON COMPANY, AS SPECIFIED IN THEIR CATALOG NO. C-2012. INSTALL NUMBER AND SIZE OF FASTENERS AS SPECIFIED BY MANUFACTURER. CONNECTORS SHALL BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. 9. SHEET METAL SCREWS SHALL CONFORM TO THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "SPECIFICATIONS FOR THE DESIGN OF COLD -FORMED STEEL STRUCTURAL MEMBERS". 10. WOOD SCREWS SHALL CONFORM TO ANSI/ASME STANDARD B 18.6.1. 11. METAL STRAPS FOR ANCHORAGE OF MECHANICAL UNITS SHALL CONFORM TO ASTM A446 GRADE A WITH A MINIMUM YIELD STRESS OF 33 KIPS PER SQUARE INCH. 12. CONNECT THE NEW UNIT TO THE EXISTING WOOD SLEEPERS WITH FOUR (4) GALVANIZED METAL STRAPS, 1-1/2" IN WIDTH. CONNECT THE STRAPS TO THE UNIT WITH #10 SHEET METAL SCREWS AND TO THE WOOD SLEEPERS WITH (2) #10 x 2" LONG WOOD SCREWS. M7PRo ro-rpWkrr oF- F cF-roF UNIT" -Z, s DEA.E 4-hC goo b >✓os 462. A�tilc-� c R.5 17 1 L, F -4,44A q * Pi. -I • Moore Engineering Group PROJECT: rJ r.l KT -Li ENGR: \.\6V DATE: 571V13 SCALE: 3/ SHEET PROTECT DESCRIPTION: The project consists of the replacement of an existing rooftop mechanical unit with a new unit. LOADS: LIVE 25 PSF DEAD Roofing and re -roof 5.0 Plywood sheathing 1.5 2x4 @ 24" o.c. 0.7 4x14 @ 8' o.c. 1.5 Insulation 1.0 MEP 1.0 Ceiling & Lights 2.0 Total Dead 12.7 DEAD + LIVE WIND 85 mph, Exposure B SEISMIC Latitude 47.449 Longitude -122.249 Site Class D to E SDs (D) = 0.960 SDS (E) = 0.864 SDs = 0.912 EQUIPMENT Existing New Unit 565# 660# Dimensions 52"x28"x28" high 74"x47"x42" 37.7 PSF Moore Engineering Group PROJECT: ENGR: DATE: SCALE: 11/ SHEET Design Maps Summary Report http://geohazards.usgs.gov/designmaps/us/summary.php?template=mi... (GS Design Maps Summary Report User -Specified Input Report Title Orkin RTU Mon March 18, 2013 14:00:54 UTC Building Code Reference Document ASCE 7-10 Standard (which makes use of 2008 USGS hazard data) Site Coordinates 47.449°N, 122.249°W Site Soil Classification Site Class D - "Stiff Soil" Risk Category I/II/III Rivennn-Baie•iard. .ko Park's Highline 011 USGS-Provided Output' SS = 1.440 g S1 = 0.536 g fry S = 1.440 g SM3 = 0.803 g (! ) 23x.3 "1'61 41Saill IJi 1" East Renton Highlands Cascade•FairAlvd Mari! • I. P.Igh13-Lake a raaM East HiII Merid9a SE 2101 SDs = 0.960 g SDl = 0.536 g For Information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.65 1.50 1.35 1.20 1.05 • 0.90 111 0.75 0.60 0.45 0.30 0.15 0.00 0.00 MCER Response Spectrum 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 Period. T (sec) 2.00 1.10 1.00 0.90 0.80 0.70 ▪ 0.60 0.50 0.40 0.30 0.20 0.10 0.00 0.00 For PGAM, TI, CRs, and CRI values, please view the detailed report. Design Response Spectrum 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 Period. T (sec) 2.00 1 of 2 3/18/2013 7:00 AM Design Maps Summary Report http://geohazards.usgs.gov/designmaps/us/summary.php?template mi... riU GS Design Maps Summary Report User -Specified Input Report Title Orkin RTU Mon March 18, 2013 14:01:08 UTC Building Code Reference Document ASCE 7-10 Standard (which makes use of 2008 USGS hazard data) Site Coordinates 47.449°N, 122.249°W Site Soil Classification Site Class E - "Soft Clay Soil" Risk Category I/11/III Salmon greet Rivenen,Bi .vaid Park o ar H-tigiline it rssa•rr r. r "i East Renton Higlihnds.- Scyliak i State' E 114 gal Burien en Cascade<Fainv ado Maple East Hill•Meridia Des Moines USGS-Provided Output S = 1.440 g S = 0.536 g St4s = 1.296 g SM1 = 1.286 g Sps = 0.864 g Sol = 0.857 g Mexico For information on how the SS and S1 values above have been calculated from probabilistic (risk -targeted) and deterministic ground motions in the direction of maximum horizontal response, please return to the application and select the "2009 NEHRP" building code reference document. 1.43 1.30 1.17 1.04 0.91 0.78 0.65 0.52 0.39 0.26 0.13 0.00 0.00 0.20 MCER Response Spectrum 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 Period. T (sec) 2.00 Design Response Spectrum 0.99- 0.90 .99- 0.90 - 0.91 - 0.72 - 0.63 - I O� 0.54- V1 0.45 0.36 0.27 - 0.18 - 0.09 - 0.00 1 1 1 1 1 1 I 1 1 I 0.00 0.20 0.40 0.60 0.20 1.00 1.20 1.40 1.60 1.80 2.00 Period. T (sec) For PGAM, To CRS, and CR1 values, please view the detailed report. 6/3 1 of 2 3/18/2013 7:01 AM ,r 8(1 ANo e cialtnolitt nbt -- Azat IN? 531 Tilt I5 r14=T 1—E. "y0 - ' akk I (Nj 7 Qi {% Kial w.xfr. lil c15 ,102 b�.. 5 % 1b. P'\ ` ''^�c'.LKus -tQ 1--. tZ - W- 4ro.'. x3;; Nka FEATURES Optional Duct Endosute — The RT10-65 duct endosure is required for installation of the unit with the RMF9-65 roof mounting frame. Duct enclosure is completely insulated with a baked -on enamel finish and is shipped knocked down for field assembly. Supply and retum air openings are located in the bottom of the enclosure. Field assembled return air plenum is furnished for ceiling diffuser applica- tions. Plenum connects to unit retum air opening segregating return air within the enclosure. Optional POWER SAVER* — The complete RD10.65 POWER -SAVER and control system is shipped factory assembled and wired. The Lennox POWER SAVER system consists of: duct enclosure, mechan- ically linked outdoor air and recirculated air dampers with pressure operated exhaust air dampers. The positioning of these dampers is accomplished by a 24 vofl 3 position spring retum damper motor with adjustable minimum damper positioner and controlled by the room thermostat, adjustable mixed air controller, adjustable com- pressor monitor and adjustable enthalpy control. The enthalpy con- trol allows 0 to 100% outdoor air to be used for "free cooling" when outdoor humidity and temperature are acceptable. The Lennox POWER SAVER will co-operate with any heating -cooling thermostat. A outdoor air intake hood is furnished and field installs over the outdoor air dampers. Shipped knocked down, it is easily field as- sembled. A cleanable polyurethane media frame fitter is fumished with the hood providing extra air filtering and bird screen protection. Optional RT10 Adapter Kit—Adapter kit (LB -2947568) includes fil- ler panels and securing brackets to mate the duct enclosure and roof mounting frame to CHA10-261, CHA10-311 and CHA10-410 models. CO At- 23-, I Optional Roof Mounting Frame— The RMF9-65 roof mounting frame mates to the unit and duct enclosure providing an automatic weather sealed installation. A mounting frame deck enclosure is furnished to provide a weatherproof deck for mounting the unit on the roof mounting frame. Approved by National Roofing Contractors Association. Optional Minimum Fresh Air Damper — OAD3-46165 minimum fresh air damper mounts external to the RTU) -65 duct enclosure. Equipped with manually operated damper and fittings for installing. Optional SP11 Remote Status Panel -- The operation of the unit can be checked on the Remote Status Panel (12F83) located within the conditioned area. Signal lights on the panel indicate "Cool Mode," "Heat Mode," "Compressor 1," "Compressor 2," "No Heat" and "Filter." The cool mode signal light is green when lit and indicates cooling operation. Heat Mode light is green and reflects heating operation and will tum red if there is an operational mulfunction_ Compressor 2 Tight is not required and should be disregarded. The No Heat and Filter lights will show red and indicate a requirement for service. Additional controls are required for use with the Status Panel and must be specified when ordering. Fitter switch kit (97C85) is used in conjunction with the Filter light. Operation of No Heat light requires an additional control. see Price Book. Wiring Junction Box (14F92) is required to interface status panel with unit operation. Box field installs in unit. SPECIFICATIONS .Vt Model No. t:HA/0.261 CHA70 311 CHA10.411 CHA10d13 CHA10-461 CHA10.463 CHA10-511 CHAj0-513 CHA1oB-651 CHA10B-683 *ARI Standard 270 SRN . 19 20 ?Q 21 ia.21 •ARI Total cooling capacity (Btuh) 2000 29,000 34,00Q - 43,000 47,500 , 56,500 Total unit watts 2590 3450 4090 5100 5950 6940 Standard 210 Ratings tSEER (Mull/Watts) 1 phase model only- 8.85 8.25 8.2 8.9 8.15 8.2 ttEER (BtuhiWatts) 3 phase model only ---- ---8.0 8.45 8.0 8.15 Dehumidifyingpiaty 26% 26% 28% 26% 25% 26% Refrigerant IR -22) charge +5 lbs. 0 oz. 5 it's. 0 oz. 5 lbs. 13 oz- Sibs. 10 oz. 8 lbs. 7 oz. 10 lbs. 0 oz. Evaporator Coil Net face area (so. ft.) 2.9 3.0 3.0 45 4.5 5.75 Tube diem. (in.) & No. of rows 112 — 2 318 — 3 3/8 - 3 3/8 — 3 3/8 — 4 3)8 — 4 Fins per inch 15 10x9 16 10x9 1,8 11 x9 16 10x10 l4 12 x 12 14 10x10 Evaporator Blower Wheel nominal diam. x width (in.) Motor horsepower 1/4 1rg 112 112 3/4 1 RPMFactory installed drives ---- ---- ---- ---- -- - 980— 1230 ranfte •'Optional mofor-pul v ---- --- -- --- ---- 1175 —1450 Net face area (sq. ft.) 11.6 11.6 11.6 115.3 15.3 18.1 Condenser Coit Tube diem_ (in.) & No. of rows 318-2 3/8-2 318-2 318-2 3(8-2 3)8 — 2 Fins per inch 13 15 15 13 15 15 Diameter (in.) and N9. of blades 20-4 20-4 20-4 •24-4 24-4 24-4 Air volume (factory setting) 3200 3200 420Q 4100 4100 5500 Condenser Fan Rpm Jfactory setting) 1035 1035 1035 825 825 1065 Motor horsepower 1/4 1/4 114 1)4 1/4 1(2 Motor watts (factory setting) -i390 300 300 320 32Q 580 Condensate drain size mot (in.) 314 3/4 3)4 314 3/4 3/4 No. & size of filters (in.) (1)16x25x1 (1)16x25x1 (1)16x25x1 (2)16x20x1 (2)16x20x1 (2)20x20x1 i Net weight of basic unit (lbs.) (1 package) 310 330 335 495 515 565 al, LB -379658 Optional Condenser Coil Guard - 3 required per unit LB -33656B LB -34491B Optional Duct Enclosure (Net weight) RT10-0 (5 lbs.) RT10-65 (85 lbs.) RT10B-65 (95 lbs.) RD10B-65 (190 lbs.) .(1)-20x25x1 Optional POWER SAVER (Net weight) andNo.&sizeoffilter(in.) RD10.65 (180 lbs.) (1)-20x25x1 RD10-65 (180 lbs.) - (1)-20x25x1 Optional Roof Mounting Frame (Net weigh RMF9-65 (110 141 RMF9-65 (110 lbs.) RT1 OIRD10 Adapter Kit (Net weight) LB -2947588 (4 lbs.) --- 4 - Optional Minimum Fresh Air Damper (Net weight! OA03-46165 (7 lbs.1 OA03.46165 7 lbs.) Optional Comb. Supply & Return Transition (Net wt.) SRT10-65 (20 lbs.) SRT10.65 (20 lbs.) Optional Combination Ceiling Supply And Retum Step -Down Diffuser (Net weight) RTD9-65 (67 lbs.) RTD9-65 (67 lbs.) Optional Combination Ceiling Supply And Retum Flush Diffuser (Net weight) FD9-65 (33 lbs.) FD9-65 (33 lbs.) *Rated in accordance with ARI Standard 270. *Rated in accordance with ARI Standard 210: 450 dm (maximum) evaporator air volume per ton of cooling capacity, 95F outdoor air temperature and 80F db/67F wb entering evaporator air. ••Optional motor pulley is furnished and must be field installed to obtain rpm range shown. t Seasonal Energy Efficiency Ratio based on DOE test procedures. ttEnergy Efficiency Ratio in accordance with ARI Standard 210. — 11 — DIMENSIONS (inches) FILTER UNIT ACCES8 cosnitot sox PANEL \ COMPRESSOR 1 L.,11 ,_. . :. -N-) ‘ i I chi% ytR, xr _ 1 7.:...filiWGUARri ._. ; • ' L1\ l i : RLTER i 1 ir I . , t 1 II 1 11 Is i 11 . I I, I.-. ,A,,-A.G.p.ar.austi rfirEargis' 11` IV LJ NCTION . , TIPTIONAL ELECTRIC HEAT (opposite sido) CONDENSER cox ENTERING AIR (Both Wm & End) 0 1-112 CONDENSER COIL EXHAUST AIR Model No. A 0 C D 8 F G H J K CHA10-261. 311 & 41 ' ?-11116 a. 28-314 24 1-13116-4 7 15 4-71ET 2-3113- 22 CHA10-460 & 510 59-1118 40-314 Z1:1 -Li 34 2-314 8 15 6 2-112 34-314 CHA106-65.9 _59-15/16 40-314 33-3/4 34 2-314 8 20 6 2-1/2 . 34-314 CENTER OF GRAVITY (in.) Model No. L M CHA10-261 29-11116 11-3/4 CHA10-311 , 29-11116 11-314 CHA10-411-413 29-11/16 11-314 CHA10-461-483 34-518 17-112 CHA10-511-513 34-518 17-112 CHA1013-651-653 0 34-5/8 17-112 INSTALLATION CLEARANCES (inches) 313 35 • 12 tn _.01.1AT.INCLOSUBE ..ERNAUST AIR:OUTLET 24 NOTE —60 inches clearance , recharge! an top of CORNER WEIGHTS (lbs.) Model No. N 0 P R CHA10-261 77 106 83 59 CHA10-311 82 113 87 63 CHA10-411-413 83 115 89 64 CHA10-461-463 130 173 126 94 CHA10-511-513 135 178 131 99 CHA108-651-653 I 147 196 143 107 NOTE— Corner weights of basic unit with elec- tric heat. OPTIONAL OAD346185 MINIMUM FRESH MR DAMPER / 12-12 9-743 itKrt445:c. 1 — 12 — FRONT VIEW AIR f FLOW SIDE. VIEW 1 0\6 Unit Report For 5T Pkg HP Project Kidder -Mathews -5T Commercial PHP Prepared By: 03/13/2013 12:57PM Unit Parameters Unit Model:.____.___....__._ _._..50TCQA06A0A3-0A0A0 Unit Size -- _ ----------....__06 (6 Tons) Volts -Phase -Hertz: .__—_ __.__.__....__—_---208-1-00 Heating Type: ------_-----..._......_..__.._Heat Pump Duct Cfg:__..._Horlzontal Supply /Horizontal Return Standard One -Stage Cooling Refrigeration Coil Lines and Filters Condensate Drain Line Size. __._.-_314 Retum Air,Filter Type: Throwaway Retum Air Filter Quantity:._.___..._..._..........__._._..._...__._4 Retum Air Filter Size:_._.—.__._._.__..._.__..._.._ 16 x 16 x 2 Unit Configuration Electric Drive X13 Al/Cu - AI/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1 -Year parts (STD.) 5 -Year Compressor (std.) No optional warranties were selected. Dimensions (ft In.) & Weight (Ib.) Unit Length: . 6' 2.376" Unit Width: 3' 10.76" Unit Height__....----...---_---------....__._ 3' 5.375" Total Operating Weight.__.____.__.___.. -_660 "' VVaights and Dimensions are approximate. VYeight does not include unit packaging. Approximate dimensions are provided primarily for shipping purposes. For exact dimensions and weights, refer to appropriate product data catalog. NOTE: Please see Warranty Catalog 500-088 for explanation of policies and ordering methods. Ordering Information 4 bi Part Number Description Quantity 50TCQA06AOA3-0AOA0 Rooftop Unit 1 Base Unit Electromechanical control, No intake or exhaust option None Accessories CRECOMZR024A02 Horizontal EconoMi$er IV with solid-state controller ' 1 Packaged Rooftop Builder 1.34 Page 2 of 8 Project: Kidder -Mathews -5T Commercial PHP Prepared By: Certified Drawing for 5T Pkg HP 03/13/2013 12:57PM VD'Cd: 1 01+(3/310/15 A3C IN '8[x15 :(3/2151083 (3 1 I AR6 E6 N1LLI8ET14S. 2. S CC4101 OF 0841171 3. * DIRECT:ON 3r AIR riOB F:LI33 ACCESS PANEL (T000-LCSSl UNIT 501E03/[/ 1617733 3/8 33 3/8 MI) 501(34.05 M1 18 5/6 .4121 147/0 73711 $OTC0A06 41 3/6 (1 7/8 110311 13711 571(0301 (341 03(13/6 14 1/6 :317: RACK 1 ---1 i.- 4-5/0 11101 0 081110 '.3. 101 4141 1EC63C7.00113 31117171. 41 CURIES 3337 11008 • 1 :1 -11 Pan ITT M Ulu LQVNr 17011,13.4 6311131 :06317. ar Ulb O. 811311614;1 a 41,1* >Dli D1K:f1r)u.l 81st. 161 U 33 338 18411 0[023812)4 3/003 1 10PT10NAL) 16 (4311 I .. j` 23.3/3 16521 I 10.1/8 RUM 8)8 ` 1873) RITURI 4.3 41 11131) 1011 OPTIONAL 3401348 INSTALLED 006YEN1'NCE CUTLET 13.115 11111 14-0/0 13-711 11 1450) I 363) If)2)12I 1 SEC T4RU TNS BASE CHART E AL1.1- COADENSATE PAIN OPIUM 31-3)4 7.N 3ASEPA8 1151) SOPPIT A3i LL_ AL - 6.114 1151 usrelcrt OISCOInal LOCATION (9.I/2 14641 411,51))1 .' =FT 75 70 381 32 1/4 18151 TOP ( 89-3/B 11111 y 26.1/2 13 31 f 3- /8 1857 72.118 -2 73113 - 18-1/2 --) 14701 00)11681 f4C"011 (ASIALLC3 DISCONNECT INDOOR 81.04:8 ACCC50 14.3/6 ::6611 FRONT 38/013 3/11 CONNECTION 51/ES A 11 3/0. 1331 DIA Fitt) 70368 SUPPLE ROLE B 12. 1511 0(4 706[8 SUPPLY 040((001 C 11 3/4. 1441 DIA DA05E ACCESS P7U3 D 1718. 1281 DIA FI1L0 CONTROL 47(146 833E [ 13/4•-l4 I.P1 [0/3(x5171 OAA74 0 12 1/2' 1641 01A P0068 SOHIT 3/80[1.001 'HAU-INE-BASF CHARI TRESS NOLIS 3/1[11(03 003/ USE CIBTHP18001401 788(3312 CONDUIT 0051 03) RE0'D 601.E SITES IIUC.) 3/2' ACC. 118. 178.81 7/2' (4/ 138. 182.0) 3/4. 11013 Pone 1 1/6. 124.41 [08 •T1I11-T30.8151 3/1• [ACTOR) OPTION. 0(1111165 TO 04LE 1 S I ARE PROVIDED 3(1[01 TITN1:)4"3R14)23•3110 R ). 3R 1)3• 3/01 001Ei- 010130)70 08 814E 312[ ( 31 1/4 SU%LN 11011 AIR RETURN RIG41 . AIR BAS38EI11C 821:E4 FL08 • lou UR 1 Cr 2 03-10-09 17111(1171 01.23-39 50TCO 04-07 5:NGLE ZONE ELECTRIC 4[.47 Pi -P 481x501531 If 5.0 „Packaged Rooftop Builder 1.34 11J Page 3 of 8 (NO ‘41? -23-1 Project: Kidder -Mathews -5T Commercial PHP Prepared By: Certified Drawing for 5T Pkg HP 03/13/2013 12:57PM 0S ry 0'0. 6451 1(IG11 COAEA 1 60 1E0 1 COCAEA GORIER 1 1423117 (41 .11,.1010 1011 *6IGNi 161 .5Ei651 (01 C 6• ' KE 166' 155. A0. 65S. CO. 1105. 16. LOS. 6. 605. (G. R 1 6 2 50160401 535 221 131 42 1 130 51 111 SS i '.23 151 134 1/4 1421;'22 1/2 15121 11 S/6 14111 50166800 $15 211 132 13 : 111 51 j 111 SI 1174. 50 30 1/4 14251122 '/5 (5621 11 1/2 141111 SOIC0464 510 210 151 72 1141 5/11 3/0 13151 20 I/8 111 30160/07 130 201 161 13 1141 15 10 1 141 1 4I 131 1/4 7111/33 122 1/5 12121 21 3/4 120 1271 CORNER A 441162 r 1. Ice 5S15 776660.00:(5 64312). n C4111E4 tan lM,�II N�j iilfi / trtii i CO IR;d11M1,1t1 CovoII:,I, sunt.:0121, pun glgd41114 wo!'t7'Dyijli!t°iui'ilr!Ftt l 50 10.66 Of 101746). CORNER 8 CORNER C !IMF i FRONT . 0 O a¢] 4a 2 or 2 1 03-10-09 A6)110n6 01-23-39 50%0 04-07 SINGLE ZONE ELECTRIC , HEAT PUMP I 48T51501501 1570! Packaged Rooftop Builder 1.34 Page 4 of 8 .CDL 6 E .,1I SPS( o ' A..55' beAp cu. „n es •2 ! 041 170 CC IA_ = 6/c) -t. '7 = 3400'1 ikto I (4 LAA z-1 iloRp r -g 3074 /OCo.r� �/S"D jJC� l►ic_t-u-c.e - 0.4 (z,S) (o5 t-4-( lace Se C3 NwZ — Ca / = 3 0 ( per. --QC_3401 K:0 Wo ce r -e fico t -C) n.(; (-74. ,4 4 -4-)/44' (44) 14; (.440 c. Vi\ -/C Moore Engineering Group PROJECT: rV ENGR: DATE: 3/1S/11 SCALE: SHEET IPERMIT COORD COP PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-058 DATE: 03/20/13 PROJECT NAME: ORKIN SITE ADDRESS: 925 INDUSTRY DR X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: tor/04 -b1� ' (77 Ar * —--2-11-1 e- Building Division " Fire Prevention IIII Public Works Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 03/21/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/18/13 Approved ❑ Approved with Conditions g Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople'nter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name COMFORT MECHANICAL UBI No. 601954041 INC Phone 4252519840 Status Active Address 3202 C St Ne License No. COMFOMI015LA Suite/Apt. License Type Construction Contractor City Auburn Effective Date 6/1/1999 State WA Expiration 4/25/2014 Date Zip 98002 Suspend Date County King Specialty 1 Heating/Vent/Air-Conditioning And Refrig (Hvac/R) Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status FIVESM'010JT FIVE STAR MECHANICAL Construction Contractor General Unused 4/30/1999 5/1/2014 Active COMFOP'064D2 COMFORT PLUS Construction Contractor Air Conditioning Air Heat,Ventilation,Evaporat 3/22/1994 3/21/2000 Archived FIVESSE941KU FIVE STAR ENERGY SOLUTIONS Construction Contractor General Unused 5/24/2006 5/24/2008 Expired Business Owner Information Name Role Effective Date Expiration Date JACKSON, SHIRLEY A President 01/01/1980 Bond Amount JACKSON, HERB J Vice President 01/01/1980 9815017 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 Lexon Ins Co 9815017 06/01/2012 Until Cancelled $6,000.0006/04/2012 04/24/2012 2 COLONIAL AM CAS & SURETY OF MD LPM4041162 06/01/2002 Until Cancelled 06/01/2012 $6,000.00 05/15/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 8 Federated Mutual Ins Co 9849307 06/01/2010 06/01/2013 $1,000,000.00 04/24/2012 7 FEDERATED MUTUAL INS CO 9849306 06/01/2006 06/01/2010 $1,000,000.00 05/01/2009 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns://fortress. wa. eov/lni/bbin/Print. asnx 04/11/2013 PAK(.LL UA I A Parcel 252304-9034 Name Site Address Geo Area Spec Area CWWA TUKWILA 1 LLC 825 INDUSTRY DR 98188 70-30 520-30 - m Property Name. Leal Description Tukwila Commerce Center (Bldgs 19, 21,23,25,27,29,31) Jurisdiction Levy Code Property Type Plat Block / Building Number Plat Lot / Unit Number Quarter -Section -Township -Range 4 TUKWILA 2340 C SW -25-23-4 BEG AT E 1/4 COR OF SEC 26-23-4 TH N 88-06-42 W 105.84 FT TH S 01-47-28. W 90.6p FT TO TPOB TH FR TPOB S 88-12-32 E 233 FT TAP ON C/L OF A PRIVATE DRIVE TH ALG SD C/L S 01-47-28 W 577.17 FT TAP OF CURVE TH TANGENT TO PRECEDING COURSE ALG ARC OF CURVE TO LFT 77.78 FT RAD 250 FT & C/A 17-49-33 TAP OF REV CURVE TH FR A TANGENT WH BEARS S 16-02-05 E ALG / RC OF CURVE TO RGT 77.78 FT RAD 250 FT & C/A 17-49-33 TAP OF TANGENCY TH TANGENT TO PRECEDING CURVE S 01- 47-28 W 430 FT TAP ON NLY MGN OF MINKLER BLVD TH LEAVING SD C/L ALG SD MGN N 88-12-32 W 257 FT TH LEAVING SD MGN N 01-47-28 E 1160.23 FT TO TPOB LESS UP RR OPER R/W PLat Block: Plat Lot: ASSESSOR DATA 2009 Washington State Energy Code Compliance Forms for Nonresidential and. Multifamily Residential Mechanical Summary MECH-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Info Brand Project Address ORKIN Date 3/19/2013 CFM 925 INDUSTRY DRIVE For Building Dept. Use SP TUKWILA, WA 98188 SEER Applicant Name: JOFFRE SECHIER Strip Heat Applicant Address: 3202 C ST NE, AUBURN, WA 98002 Location Applicant Phone: 425-251-9840 Project Description Briefly describe mechanical system type and features. ❑ Includes Plans REPLACE (1) 5 -TON ELECTRIC/ELECTRIC PACKAGED ROOFTOP UNIT WITH NEW 5 -TON HEAT PUMP WITH ECONOMIZER. Include documentation requiring compliance with commissioning requirements, Section 1416. Compliance Option 0 Simple System 0 Complex System 0 Systems. Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH-SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling E. uipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception Heat Recovery Y/N 27-1 HP CARRIER 50TCQA06 - 61130 ECONO 13'; N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N 27-1 HP CARRIER 50TCflA06 58310 ECONO 7.7 HSPF Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' CFM SP' HP/BHP Flow Controls Location of Service 'If available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. 4 COP HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 1433. 925 Industry Dr Tukwila, WA 98188-3413 14013 M.piw .t - PoUomrn 1¢013 I Edna SEPARATE PERMIT REQUIRED FOR: 1Mec ani:aal Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE. APPROVED APR 09 2013 City of u iIa BUILDING ISION AI PROJECT DESCRIPTION: 1. REPLACE (1) 5 -TON ELECTRIC/ELECTRIC PACKAGED ROOFTOP UNIT WITH NEV! SAME CAPACITY HEAT PUMP UNIT WITH ECONOMIZER.' GENERAL NOTES: 1 E- 100% TO PROVIDE OUTSIDE AIR WITH PARTIAL COOLING AND MULTIPLE COOLING STAGES. 2. THERMOSTAT TO PROVIDE MINIMUM 5° DEADBAND. 3.7 -DAY PROGRAMMABLE THERMOSTAT WITH LOCKOUT. e 4. INSTALL GFCI OUTLET WITHIN 25, OF UNIT. 5. INSTALL RETURN AIR DUC SMOKE DETECTOR FOR UNITS WITH GREATER THAN 2,000 CFM 6. ROUTE CONDENSATE TO SPLASH BLOCK ON ROOF. 7. PROVIDE AIR BALANCE AND COMMISIONING REPORT. 8. PROVIDE O&M MANUALS WITH STAFF TRAINING. 9. VERIFY ALL DUCT DIMENSIONS PRIOR TO INSTALLATION. 10. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS. 11. INSULATE ALL DUCT PER WSEC TABLE 14-5. 12. SEAL ALL DUCT PER WSEC. HVAC Equipment Schedule Unit # Brand Model Ton CFM OSA Econo. SP Cap. Cool SEER Cap. Heat Strip Heat Weight Location HP -27-1 Carrier 50TCQA06 5.0 2000 120 0-100-- 0.5 61,130 13.2 58,310 0 660 Roof FILE C PY Pit No. MI 1< Plan review approval is wed to encs and omissions. Mc off construction documents does js�n�ott authorize Mc Viiolation of any adopted code or ordinance. Receipt of approved ld and =Mons is admowledged: BY - - Ti'4fuJ% ADJACENT TENANT "NO WORK" NEV 4x P.T. SLEEPERS ROOF ACCESS BY EXT. LADDER REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan reviewfees REV ISIONS ti z MECHANICAL, H 0 L�. 0 v DATE: SCALE: DRAWN: CHECKED: RECEIVED CITU OF TUKWILA MAR 2 0 2013 PERMIT CENTER 00-000 1