Loading...
HomeMy WebLinkAboutPermit M13-059 - INNOVASIAN CUISINE - REPLACE ROOF TOP UNITINNOVASIAN CUISINE 18251 CASCADE AV S M13-059 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 7888900150 Address: 18251 CASCADE AV S TUKW Project Name: INNOVASIAN CUISINE Permit Number: M13-059 Issue Date: 04/11/2013 Permit Expires On: 10/08/2013 Owner: Name: CASCADE TUKWILA LLC Address: 7900 SE 28TH ST #200 , MERCER ISLAND WA 98040 Contact Person: Name: Address: Email: Contractor: Name: Address: Contractor ALEX BURIRART 727 S KENYON ST , SEATTLE WA 98108 ALEXB @ E VERGREENHVAC. C OM EVERGREEN REFRIGERATION LLC 727 S KENYON ST , SEATTLE WA 98108 License No: EVERGRL954R2 Phone: 206 763-1744 x 247 Phone: 206 763-1744 Expiration Date: 01/06/2014 DESCRIPTION OF WORK: REPLACEMENT OF (1) ROOFTOP UNIT, DUCTWORK, GRILLES AND DIFFUSERS Value of Mechanical: $8,353.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $293.81 International Mechanical Code Edition: 2009 Date: 1--t 4-13 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Date: / 1 q13 Print Name: A61 -- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 11149 nen D...., 1• !1A_11 J)Al1 r • PERMIT CONDITIONS Permit No. M13-059 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: Insulating materials, where exposed as installed in buildings of any type of construction, shall have a flame spread index of not more than 25 and a smoke development index of not more than 450. Where facings are installed in concealed spaces in buildings of Type III, IV, or V construction, the flame spread and smoke -developed limitations do not apply to facings, that are installed behind and in substantial contact with the unexposed surface of the ceiling, wall or floor finish. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Ventilation is required for all new rooms and spaces of new or existing buildings and shall be in conformance with the International Building Code and the Washington State Ventilation and Indoor Air Quality Code. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-059 Printed: 04-11-2013 CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. . —OC\ Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 2-5 ( C Ave- s Tenant Name: 1hV1 C2 v A In King Co Assessor's Tax No.: ' b ) S b Suite Number: Floor: New Tenant: ❑ Yes ❑ ..No PROPERTY OWNER Name: Jae., j3 -i4 -- Address: -7 2I 5°A.4, v v, s'E" Name: (,m 4e T* ,c&. LA, Email: tt 6e e,\,,er,,\+'ee - kvac.1owt Address: -7 1 db SF S i City: iU1ci 3,5ta{v2 State: fk Zip: co 0146 CONTACT PERSON — person receiving all project communication Name: Jae., j3 -i4 -- Address: -7 2I 5°A.4, v v, s'E" City: eiAiikC, State: \j, Zip: "A C t)- Phone:206=%--5— rick/ Fax: 22,6_-7,`1,— 2wci, Email: tt 6e e,\,,er,,\+'ee - kvac.1owt MECHANICAL CONTRACTOR INFORMATION Company Name: S,? lteCrr pvi Address: 2;7 C �.� V �a� 5 - , Jam' t State: W %fir Zip: et i q City: Sc4, Phone: -06-7c-- N44. Fax: 2,06 _?63 _ 23,0 Contr Reg No.: Fv (s('LLccSN%zzExp Date: \ /6, /�q / Tukwila Business License No.: NS _ Oeteurrii Valuation of project (contractor's bid price): $ 5 3 Describe the scope of work in detail: .Yr 64 -AAAA -yvn 64' 0H2 1 C� Yt4 N C l Lce,vnci. Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ ties./ clffusvs Fuel Type: Electric ❑ Gas [' Other: H:\Apphcattons\Forms-Applications On Line\201 1 Appltcanons\Ivlechamcal Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit I <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING WNER OR AUTHORIZED AGENT: Signature: Print Name: Mailing Address: 127 Jok '' ;vn , Day Telephone: S Date: 3 h 3 ',JA- 406-6 City H:\Applications\Forms-Applications On Line\20I 1 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh State Zip Page 2 of 2 CA of Tukwila, • Department of Community Developmen t 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www. ci. tukw ila.wa. us SET RECEIPT Copy Reprinted on 03-22-2013 at 12:34:37 03/22/2013 RECEIPT NO: R13-01113 Initials: JEM Payment Date: 03/22/2013 User ID: 1165 Total Payment: 1,006.22 Payee: EVERGREEN REFRIGERATION, LLC SET ID: S000001944 SET NAME: EVERGREEN MECHANICAL SET TRANSACTIONS: Set Member Amount EL13-0288 63.00 EL13-0289 63.00 M13-001 489.81 M13-059 293.81 PG13-042 96.60 TOTAL : TRANSACTION LIST: Type Method Description Amount Payment Check 005860 1,006.22 TOTAL: 1,006.22 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.101.00.0 000.322.103.00.0 000.322.102.00.0 000.345.830 TOTAL: 126.00 96.60 626.90 156.72 1,006.22 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 ff 13 -0-5c-1 Project: , i NNOvASLP eliSIK.�. Type of Inspection: !—} NiA t Address: t )1 S I (IAS6 W ild Date Called: G Special Instructions: Dateanted:. �'I— I( -r3 • ra.m, pm. Requester.: Phone No: z53 - 91-1 6 -Z7 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: Insp ctor: /. �. 11, I .XI -4 . REINSPECTION FEE RE QUIRED.. Prior to !next inspection, fee must be p id at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Dat : INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. ty-1 1 3 --fit CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 if. (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Protect: .I-NINIDV' 5IFlW Cu ►Sit. Type of Inspection: QCLatl 1 =1--h0 Address: i82 1 cj'ADe_ Date Called: Special Instructions: Dateante r (a.,om1? Requester: Phone No: —..5Q 32. 93 I LApproved per applicable codes. Corrections required prior to approval. COMMENTS: Irfspe or: Date . 7 - - T 0�R INSPECTION FEE RE UIRED. Prior So next inspection. fee must be 15 id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. EVERGREEN REFRIGERATION, LLC 727 S KENYON ST. SEATTLE, WA. 98108 206-763-1744 CONTR. # EVERGRL954R2 «`d5cj TEST AND BALANCE REPORT Project: InnovAsian TI Evergreen Job #: 513069 Date: March 25, 2013 Location: 18251 Cascade Ave South Tukwila, WA 98188 Engineer: EVERGREEN REFRIGERATION LLC Evergreen Refrigeration LLC, has balanced the system described in accordance with the plans, specifications, and within the limitations of the equipment. The testing, balancing, and adjusting has been performed in accordance with industry standards. The results of these tests are herein recorded. Commissioning Technician: Date completed: 13 AIR OUTLET TEST REPORT - SUPPLY EVERGREEN REFRIGERATION, LLC Page 1 Project: InnovAsian TI Job #: 513069 Date: 3/25/13 Unit # Area Served Outlet Design Target Preliminary Final No Type Size C.F.M. C.F.M. C.F.M. C.F.M. C.F.M. RTU -1 Storage S1.1 MCD 10 300 7-- 12-0 L/i j 3 -Lo 3,)-n Storage S1.2 MCD 10 300 - 1 00 re 3v1 3 D 7 S1.3 300RS 150 - /So i * jq, Vii S1.4 300RS 150 • /Do oil iSr iStS— S 1.5 300RS 150 . /$O 3 2., ('3t 13, S1.6 300RS 150 -/ W 7r Pr 1 3 Total CFM 1200 ill 6 OSA CFM 240 Tonnage 3 3 VICINITY MAP SCALE: NONE COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 14183.42 AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.3.4.1 ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.321. 7/..11.1,14•1•I•1:1 EY W. • - .T1 x •, A. A U NCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1418.3.3. FOR ALL OTHER SYSTEMS: (MAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED. SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PIANS PER WSEC SECTION 141633. NECESSARY TESTS SHALL BE DENTIFIED PER WSEC SECTION 141633; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OFA FINAL CERTIFICATE OF OCCUPANCY PER VI/SFC SFCTIOR 1416 34 t AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 14184 GAS PACKAGE EQUIPMENT SCHEDULE MARK MANE. MODEL TONS. AIRFLOW SP MOTOR MIN. OSA DRIVE COOLING HEATING ELECTRICAL WEIGHT NOTES CFM INS HP CFM SME TOTAL SEER EER INPUT OUTPUT AFUE VOLTS PHASE M.CA N. SMP WT L _ F5D FIRE/SMOKE DAMPER (1205 POWER REQ.) CEIUNG RADIATION DAMPER 0 SD BTUH Q T BTUH STUN (%) (V) 6R (A) Fuse (A) LBS RTU 1 LENNOX ZGA038S4B 3 120D 0.W 1.5 240 BD *000 13.0 11.3 65,060 52,000 80% 208-230 10 32.0 45 497 1 NOTE: 1. THE ROOFTOP UNIT COMES WITH AN ECONOMIZER IN ACCORDANCE WITH THE WSEC SEC. 1423. ONS No changes shall l e made to the s e of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. FILE COPY Permit No._ (20 review approval is sublect to effOrS and . proval of conte documents does not authorize e violation of any adopted code or ordnance. Receipt approved Field Copy and conditions eked: City Of lbkwil BUILDING DMSION SEPARATE PER REQUIRED - O R Electrical Plumbing 1l Gas Piping City of Tukwila 1 BU'LDING DIVISION 150 150 EXISTING DUCT Nt-AP.r///�//, 17 l STORAGE V°7/////// 10' 150 150 FLOOR HVAC PLAN ` RELOCATED TSTAT CIU / / / / / / / / 12 SCALE: 1/8" =1'-O" G GENERAL NOTES WED FO CODE COMPLIAN APPROVED APR 0 9 2013 DL City o Tu ILDING 3TON REPLACE EXISTING 5 TON UNIT WITH NEW 3 TON UNIT ` GAS FROM EXISTING FURNACE LOCATED 10 AWAY EXISTING DUCT RECEIVED CITY OF TUKWILA MAR 2 2 2013 PERMIT CENTER �Cwila 1VISION DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2' TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4'T0 EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FlRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE ALL RATING 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A RAME LESS THAN 25 ANDA FLAME SMOKE DEVELOPMENT RATING LESS TUN 50, PER IMC 60221. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 12 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD R5-7. 1.5 ALL DUCT GAUGES PER SMACNA IMC 8034. 1.6 ALL DUCT SUPPORTS PER SMACNA IMC 603.10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T.BAR GRID PER WA STATE 8 LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS INSULATION 21 INSULATE OR UNE DUCTWORK PER WA STATE ENERGY AND MECHANICAL CODES. 22 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCA. ENERGY CODES. GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEIUNG, FLOOR AND WALL PENETRATIONS, INCLUDING WEATHERPROOF 5EAJNG AND FIRE PROOF UNING PER IMC 61BC. 3.2 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHAMCAL WORK 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT. 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERI. PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OFT -BAR CEIUNG AS REQUIRED FOR HVAC INSTALLATION. 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BYSECDON 707 OF IBC. gLECTRICAL 4.1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR. 4.2 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS NECTS, AND STARTERS FOR MECHANICAL EC APMENT. C ERL MECHANCON I�CALRAN ATOR TO N RD WITH Y FIELD CONDR1ONSL04DS AND LOCATIONS CTIOCAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WIN LIGHT TCH. TO PROVIDE 7 -DAY NIGHT SETBACK, PROGRAMMABLE TYPE TSTAT WITH Ca ABI2TY OF 5'F DEAOBAND. 4.6 ECL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER 4.7 CTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCF1 OUTLET WITHIN 25 FT EACH PIECE OF MECHANICAL EQUIPMENT. 43 PLUMBING 5.7 52 UMBING CONTRACTOR TO FURNISH AND INSTAL ALL GAS PIPING FOR CHANICAL EQUIPMENT PER CODE UMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL INIAC FRESH INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE IMC 401.4.1. 5.3 &)NDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12' OF UNIT. NDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. Y CODE COMPLIANCE 6.1 ARTA MINIMUM, EACH FLOOR IS TO BE CONSIDERED A SEPARATE ZONE VERIFY ERMOSTATIC CONTROL FOR EACH ZONE AS INDICATED ON PIANS. UTSIDE AR INTAKES EXHAUST OUTLETS, AND RELIEF OUTLETS SEINING NDITIONED SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE TICALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE WSEC SEC. 14124.1. 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABIUTY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL COMPLY WITH WSEC SEC. 7423 MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOUNG AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER INC 608. M 13 --- 0C1 SYMBOL LEGEND SYMBOL ABBV. DESCRIPTION ® DUCT SECTION SUPPLY El DUCT SECTION - RETURN/EXHAUST RECTANGULAR DUCT 1 ROUND DUCT V \ FLEXIBLE DUCT AND MANUAL VOLUME DAMPER B00 BACKDRAFT DAMPER MD MOTORIZED DAMPER FD FIRE DAMPER _ F5D FIRE/SMOKE DAMPER (1205 POWER REQ.) CEIUNG RADIATION DAMPER 0 SD SMOKE DETECTOR Q T THERMOSTAT ® S SENSOR 6R REFRIGERANT LINES 6...-- G NATURAL GAS LINES 0---.......--G 12 CEILING DIFFUSER (SUPPLY) ICI CEIUNG DIFFUSER (RETLRN/EXHALST) S EXHAUST FAN (CEILING MOUNTED) ILC7y1 r INLINE FAN PROPELLER FAN `,1 / SIDEWALL DIFFUSER 111 DUCT FITTING 1.0.J.T D.U. 12', 2' DATUM -.."--S UNIT TAG IlD DUCT RISER IaAaa ONI 11.11-11101•111. RCMv ow Mmucv mama FAX(206) 763 - 2389 gaga ❑ AS BUILT DRAWINGS INNOVASIAN TI HVAC COVER SHEET 2 1- 0 w� Q wco O) U� Q 0 ou 1-r REVISIONS NO DATE ITEM EVERGRL954R2 DRAWING DATE: 03/15/13 DWG. 8Y: GN CHK. BY: DP JOB NO.: 513069 DWG. FILE: 513069M1 EE' M 1 1 OF 1 SHEETS 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential M - chanical Summary MECH-SUM Revised December 2010 Project Info �E �i®�� vette itsR‘..- -- Project Address 18251 Cascade Ave S Date 3/18/2013 Tukwila, WA 98188 For Building Dept. Use REVICIli FOR MPLIANCE Applicant Name: Evergreen Refrigeration CODE CO Applicant Address: 727 S. Kenyon St. Seattle, WA 98108 APPROVED f Applicant Phone: 206-763-1744x247 APR Project Briefly describe system type Includes Description mechanical and features. Plans Installation of one (1) rooftop unit. Drawings must contain notes requireing compliance • City of Tukwila BUILDING DIVISION , "6 with commissioning requirements - Section Compliance Option ® Simple System 0 Complex System 0 Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH-SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exception Heat Recovery Y/N RTII-1 Lennox ZGA036S4B 36000 240 13 1,01017/A Econmizer N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency4 Heat Recovery Y/N RTII-1 Lennox ZGA036S4B 52000 240 65000 52000 80 N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 CFM SP1 HP/BHP Flow Controls Location of Service 11f availatREC2EIVED according to Table 14-1A through 14-1G. 3 If required. ° COP HSPF, Combustion Efficiency, or AFUE, as applicable. 5 FerrytrottperU 'r CrrAolume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 1433. MAR 2 2 2013 PERMIT CENTER 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 System Description See Section 1421 for full description of Simple System qualifications. All Systems: ' No humidification? J No Reheat? If Heating/Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ❑ Air cooled? ❑ Packaged sys? 2� ❑ Cooling Cap <=15 Btuh/ft. J <=84,000 Btuh? J Economizer ❑<=135,000 Btuh? ❑ HeatingCap.> 0 & <=10 Btuh/ft2? If Heating Only: • <1000 cfm? ❑<30% outside air? III Heating Cap. <=10 Btuh/ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. ( START ) ap <=15 Heat/Cool Eq. with Cap <=10 ft2, or Yes Yes /ft ? Heating/Cooling or Cooling Only Heating Only Reference Section 1421 Yes Yes Yes Yes Simple System Allowed (section 1420) 1 alifies Economizer Exception tion 1 Yes Use Complex Systems (section 1430) Complex Systems Refer to MECH-COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist MECH-CHK Revised December 2010 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Project Address 18251 cascade Ave s Date 3/15/2013 The followin information is necessary to check Washington -State Nonresidential Energy Code. a mechanical permit application for compliance with the mechanical requirements in the Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401-1424) 1411 Equipment Performance Yee 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M1 N.A. 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & jacket loss N.A. 1411.1 Air-cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water-cooled chiller Full -load and NPLV values adjusted for any non-standard conditions N.A. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule N.A. 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls N.A. 1412.1 Temperature zones Indicate locations on plans Yes 1412.2 Deadband control Indicate 5 degree deadband minimum M1 N.A. 1412.3 Humidity control Indicate humidistat Yee 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback Ml N.A. 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage N.A. 1412.4.2 Optimum Start Indicate optimum start controls N.A. 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule N.A. 1412.6 Combustion heating Indicate modulating or staged control Yee 1412.7 Balancing Indicate balancing features on plans M1 N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high -occupancy areas N.A. 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. N.A. 1422 Thermostat interlock Indicate thermostat interlock on plans N.A. 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. Yee 1413.1 Air Econo Operation Indicate 100% capability on schedule M1 N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N.A. 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. N.A. 1413.3 Integrated operation Indicate capability for partial cooling N.A. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems N.A. 1414.1 Duct sealing Indicate duct design pressures, sealing, and testing requirements N.A. 1414.1.2 Low press. duct test Indicate applicable low pressure duct systems shall be leak tested N.A. 1414.1.3 High press. duct test Indicate high pressure duct systems shall be leak tested, and identify the location of this ductwork on plans N.A. 1414.2 Duct insulation Indicate R -value of insulation on duct 1415 Piping Systems N.A. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements Yee 1416.3.2 System Balancing Indicate air and water system balancing requirements M1 Yee 1416.3.3 Functional Testing Provide sequence of operations and test procedures. M1 Yes 1416.3.4 Documentation Indicate O&M manuals, record drawings, staff training M1 Yes 1416.3.5 Comm. Report Indicate requirements for final commissioning report M1 N.A. 1416.4 Compliance Chklist Submit to building official upon substantial completion. Yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential .Mechanical Permit Plans Checklist Continued MECH-CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address 18251 cascade Ave 8 Date 3/15/2013 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington -State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440-1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R-10 insulation under tank N.A. 1442 Shut-off controls Indicate automatic shut-off of circulators or heat trace N.A. 1443 Pipe Insulation Indicate R -value of insulation on piping N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. 1460 Heated Pools N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R-12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction COLD STORAGE (Sections 1460-1465) 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sections 1401-1424 or 1440-1465 , provide explanation: CT ENGINEERING INC. STRUCTURAL CALCULATIONS Replacement RTU for 18251 Cascade Ave. S. Tukwila, WA Mechanical Contractor: Evergreen Refrigeration, LLC 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206) 285-0618(F) Scope of Work: Review location and framing for replacing RTU. Existing unit is 4 -Ton unit, replacement is a 3 -Ton unit. The existing curb will be re -used. Code: UBC 2009 Edition Loads: Unit 484# Seismic SDS .925 Structural Engineers REVIEWED FOR CODE COMPLIANCE APPROVED APR 0 9 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAR 2 2 20 ,3 PERMIT CENTER ti1113-osi C T ENGINEERING 1 N C. Project: IZIli Rk-7=t,.Ac..t✓t,va\n - 1 s2 S1 C.k.%C E Date: Via/ Client: Page Number: 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: (206) 285-0618 ‘S 3 -1=1Q um i'. .":44-vtoe3 S4t,c2 Tort. vv -r" � 4- dO tem. \ t \cTrz.Q%.bEse,, We :tM"� I� �' t' %; `1 It a .. ' . - 10211 (10 Ll..."1!C5 tz-t oLV L (Ti s Ftp. -1,\ 4 IA -r4 t:14 k-t2)row - R5 -1(=A t-Wki boa c� S 110 CTI CY444t- MIA ►M t cl Tc> 7.1))10.144- r( E. 1174-6-; ¶'1 Ldp s �'c� Tve. Tit toss t t�a- 1M j \14 b1-�j' -�kk. tv :r, luWiV .�� st-pa_LNN pits N\ts-1.44/-ti E. "►- c. e.M.1 1, so-tj 7 t r c L'.ktgel 6,,,..)avt, \ 2 Et) .vet..._ .4 Lib oo-tifzetk: . 4 3 9 k.‘ , 122.2 vii: 3'AtL��� .= '70 $ S� = •old Sri Q .12.3 n . Soc. r t52A , 4a,P SDsNA1 C (1+ r •. . 4 (2. zs (454 Ca 212\- 1.9m 2 z = V F `?.(0 _ C'.0 43, t I, nsc Cur %EES 24 C/4 C.LfS7- Lt - LI P Ct P g c.1,1L( 2 of o s c,+ tau- te: 1-x^4 2CSIA) . 2qi f J CLIP :17---cl°s6-tcre:t1/41 -� 02-11) _-11(x' ) ate, C.un.a To Dc k_ Ltd . 3-.1 CIALCt MeV) t coop to Not S .-- 05 C T ENGINEERING IIN C. A • Project: 1� K.ei�C.l.= l' 1 (V Z.St CACA(rD� !' u Date: Client: 3/t2,`13 180 Nickerson St, Suite 302 Seattle, WA 98109 (206) 2854512 FAX: Page Number: (206) 285-0618 Lennox Industries Inc. - Product Submittal Table of Contents System ID Qty Model Description 3T PACKAGE GAS/ELEC 1 ZGA036S4B PKGGE/3TON/65KB/208 1 Project: 3000336912 Innovations Quote: 4000400060 Innovations Page 1 of 7 Last Changed: CHRIS GREGORY Prepared On: 2013-03-14 Phone: 206-763-1744 Lennox Industries Inc. - Product Submittal System ID: 3T PACKAGE GAS/ELEC Package Model: ZGA036S4B Description: PKGGE/3TON/651CB/208-1 HEATING PERFORMANCE Heat Source Natural Gas H/E HighInput 65000 (Btuh) H/E HighOutput 52000 (Btuh) System HeatOutput 52000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0.50 (in.) 40.1 (°F) 80 1 7 (in.WC) COOLING PERFORMANCE Refrigerant R -410A ARI EER 11.5 ARI SEER 13.0 ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool Environ Refrigerant Charge 3000 (W) 36100 (Btuh) 34600 (Btuh) 35800 (Btuh) 34702 (Btuh) 26134 (Btuh) 25036 (Btuh) 4 LBS. 1 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling CondenserDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 1 1 1.00 (in.) 95.0 (°F) 95.0 (°F) 80.0 (°F) 67.0 (°F) 59.0 (°F) 57.2 (°F) 59.9 (°F) 57.5 (°F) 9.1 (lb/hr) 9.1 (lb/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM ELECTRICAL 1200 (cfni) TotalStaticPress 1200 (cfm) Air Filter Qty 0.60 (in.WC) Air Filter Length 0.35 (hp) Air Filter Width 1.50 (hp) Air Filter Thickness CAV Belt Drive 967 (rpm) 678 (rpm) 1035 (rpm) 0.60 (in.WC) 4 16.0 (in.) 20.0 (in.) 2.0 (in.) Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage DIMENSIONS 208V 1Ph 60 (Hz) 32.0 (amp) 45 (amp) 16.7 (amp) 29.4 (amp) +/- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 11.0 (amp) 1.7 (amp) 250 (W) Cabinet Width Cabinet Length Cabinet Height Total Weight Project: 3000336912 Innovations Quote: 4000400060 Innovations Page 2 of 7 47.3 (in.) 75.9 (in.) 36.9 (in.) 484 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 12.1 (in.) 17.8 (in.) 25.6 (in.) 10.9 (in.) Last Changed: CHRIS GREGORY Prepared On: 2013-03-14 Phone: 206-763-1744 *EMIT COORD Chi PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-059 DATE: 03/22/13 PROJECT NAME: INNOVASIAN SITE ADDRESS: 18250 CASCADE AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division Public Works NSA- 1-161) Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1K Incomplete ❑ DUE DATE: 03/26/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route IV REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 04/23/13 Approved ❑ Approved with Conditions .4Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople PO ter Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name EVERGREEN REFRIGERATION LLC UBI No. 602512953 Phone 2067631744 Status Active Address 727 S Kenyon St License No. EVERGRL954R2 Suite/Apt. License Type Construction Contractor City Seattle Effective Date 1/6/2006 State WA Expiration Date 1/6/2014 Zip 98108 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EVERGHH910J0 EVERGREEN HOME HEATING & ENGY Construction Contractor General Unused 4/20/2009 4/20/2015 Active EVERGI*201D7 EVERGREEN REFRIGERATION INC Construction Contractor General Unused 3/27/1980 7/31/2006 Re Licensed Business Owner Information Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC Partner/Member 12/22/2005 Bond Amount PATTON, DAVID Partner/Member 01/06/2006 WA15097 PATTON, RODGER Partner/Member 01/06/2006 PATTON, MATTHEW Partner/Member 01/06/2006 TRAVELERS CAS & SURETY CO Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Merchants Bonding Co (Mutual) WA15097 01/01/2012 Until Cancelled $12,000.00 12/15/2011 1 TRAVELERS CAS & SURETY CO 104667361 01/01/2006 Until Cancelled $12,000.00 01/03/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 AMERICAN FIRE AND CASUALTY COM BAW54192293 07/31/2010 07/31/2013 $1,000,000.00 07/29/2012 2 Continental Western Ins Co CWP2640663 07/31/2006 07/31/2010 $1,000,000.0003/23/2009 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns://fortress.wa. eov/lni/bbin/Print. aspx 04/11/2013