Loading...
HomeMy WebLinkAboutPermit M13-063 - NISSIN TRANSPORTATION USA - ALTERATION1VISSIN TRANSPORT USA 18436 CASCADE AV S M13-063 City mTukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: httn://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 7888900030 18436 CASCADE AV S TUKW Project Name: NISSIN TRANSPORTATION USA Permit Number: Issue Date: Permit Expires On: M13-063 04/15/2013 10/12/2013 Owner: Name: Address: Contact Person: Name: Address: Email: EPROPERTY TAX INC DEPT 207 PO BOX 4900 , SCOTTSDALE AZ 85261 MIKE RICHEY PO BOX 33326 , SHORELINE WA 98133 MIKERICHEY@COMCAST.NET Contractor: Name: MIR MECHANICAL LLC Address: PO BOX 33326 , SEATTLE WA 98133 Contractor License No: MJRMEML913R8 Phone: 206-714-6374 Phone: 206-714-6374 Expiration Date: 12/28/2013 DESCRIPTION OF WORK: INSTALL NEW TO CONVERT SYSTEM FROM OPEN CEILING CONCEPT TO A NEW T -BAR CEILING, WITH NEW DUCTWORK, DIFFUSERS AND GRILLES. Value of Mechanical: $6,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $257.06 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: 1/- \ \f C (1-k c This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Date: tf[ I s I 1.3 11A14 AC1 Dr; n+nrl• AA _I f. 9A14 PERMIT CONDITIONS Permit No. M13-063 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 'Inn• IIUC_All n M11 -0R1 Printed: 04-15-2013 • • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 htth i'/www_.TilkwiIaWA.gpv Mechanical Permit No. ( .J- 0 % 3 Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 7888900030 Site Address: 18436 Cascade Ave. S. Suite Number: 120 Floor: 1st Tenant Name: Nissin Transport USA New Tenant: ® Yes ..No PROPERTY OWNER Name: CBRE Address: 20415-125nd Ave. S. Suite #210 City: Kent State: WA Zip: CONTACT PERSON — person receiving all project communication Name: Mike Richey Address: PO Box 33326 Address: PO Box 33326 Phone: (206) 714-6374 Fax: (206) 533-0628 City: Shoreline State: WA Zip: 98133 Phone: (206) 714-6374 Fax: (206) 533-0628 Email: mikerichey2comcast.net MECHANICAL CONTRACTOR INFORMATION Company Name: MJR Mechanical Address: PO Box 33326 City: Shoreline State: WA Zip: 98133 Phone: (206) 714-6374 Fax: (206) 533-0628 Contr Reg No.: MJRMEML913R8 Exp Date: rt. -03 Tukwila Business License No.: (So c _ 0, 9 26 cit Valuation of project (contractor's bid price): $ lot al) Describe the scope of work in detail: Install new to convert system from open ceiling concept to a new T -bar ceiling, with new ductwork. diffusers and grilles. Use: Residential: New ❑ Replacement ❑ Commercial: New Replacement ❑ Fuel Type: Electric ❑ Gas Other: H:\ Applications\Forms-Applications On Line\2011 Applications \Mechanical Permit Application Revised 8-9-1 Ldocx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 6 Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm 6 Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser 6 Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). 1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE /7' AU O ED AGENT: Signature: Print Name: Mailing Address: v F /(L\ckkt m'7\ 1"53g, H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: 'ft 5 ( 5 Day Telephone: A. °Lo 7 (( - C:1/ T 5�1 o@.EL t,� F ,mak 6 133 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 7888900030 Address: 18436 CASCADE AV S TUKW Suite No: Applicant: NISSIN TRANSPORT USA RECEIPT Permit Number: M13-063 Status: PENDING Applied Date: 04/08/2013 Issue Date: Receipt No.: R13-01234 Initials: User ID: WER 1655 Payment Amount: $257.06 Payment Date: 04/08/2013 08:42 AM Balance: $0.00 Payee: MJR MECHANICAL TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 174204 ACCOUNT ITEM LIST: Description 257.06 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 205.65 000.345.830 51.41 Total: $257.06 ,a,...• oo..einf_na Printed: 04-08-2013 -450 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION C� 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 ; imi3-o63 Project: �V tj,ss, TrAAspoir Type o .Inspection: ;,J �'�- Ake Add �s: 3� ( Date Called: Special Instructions: Date Wanted: `` (3 f f---; p.m. Requester: Phone No: Approved per applicable codes. El Corrections required prior to approval. COMMENTS: f PO; 1A(---7) Inspecto OLKO k A Date: i3 u�. r7REINSPECTION FEE REQUIRED. Pri r to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-367 /01j( k. Permit Inspection Request Line (206) 431-2451 AA(3-0G3 Project: , Al , S5 , n `HAAS, Type of ICspection: • t-1 SP A- L J e (J 1 Address: / �31� 1.�:5cMe Date Called: Special Instructions: Date Wanted n s-! a.m.'.p. _ (i m. L Requester: - hoyn. N� l 1 -(05)74 Approved per applicable codes. Corrections required prior to approval. COMMENTS: > Of- 4 PACe gear-- ( V 0 K— 11-) v Cott- = A .: Iii J i o f D t Inspi'ctor: r ck,-A Date4 ` S - /3 1 n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 q (206) 431-3670 Permit Inspection Request Line (206) 431-2451 A4(3 -003 Project:. Typ of Inspection: / Address: i X43 g (kJ Date Called: � Special Instructions: Date Wanted:. % (a,m1 Requester: Phone No: j(Q——7(-4 -0291 1 Approved per applicable codes. COMMENTS: Corrections required prior to approval. i E A r I; Insptdctor: v � i n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. MJR Mechanical PROJECT UNIT NO. 13 ,c9(0_3 Date: 4/29/2013 AIR DISTRIBUTION - OUTLET TEST REPORT Technician: Richey Nissin Transportation USA Report By: JOB NO. Test Date: 04/27/13 Diffuser # AC -1 2 Ton DIFFUSER DESIGN PRELIMINARY FINAL VARIANCE MINIMUM ROOM NAME TYPE SIZE AK CFM READING CFM READING CFM % CFM 1 Comer Office 1 10 400 375 175 375 260 2 Office 10 Office North 400 450 450 255 3 Open Office SW 8 3 250 285 2�ECFIVEp 195 4 Open Office SE 220 8 250 Open Office 245 CI7' 5OF TUKWILA 195 5 250 185 5 Open Office 6 180 200 6 Open Office 7 195 175 210 7 APR ,� 0 2u13 8 300 220 260 8 Open Office 9 300 260 270 PERMIT 9 Break 10 215 100 185 CENTER 10 TOTALS 800 0 0 825 0 825 0 COMMENTS: Cooling Supply Air Temperature: Heating Supply Air Temperature: AC -1, Carrier 48GS-0180040301, 40 MBH Input Gas heater 57 DESIGN HEATING CFM 105 ACTUAL HEATING CFM Diffuser # AC -2, 2-1/2 Ton DIFFUSER DESIGN PRELIMINARY FINAL VARIANCE MINIMUM ROOM NAME TYPE SIZE AK CFM READING CFM READING CFM % CFM 1 Open Office NW 1 8 250 260 175 260 260 2 Open Office NE 8 Office North 250 200 200 255 3 Open Office SW 8 3 250 285 2�ECFIVEp 195 4 Open Office SE 220 8 250 Open Office 245 CI7' 5OF TUKWILA 195 5 250 185 5 Open Office 195 180 200 6 Open Office 7 195 175 210 7 APR ,� 0 2u13 8 300 220 260 8 Open Office 9 300 260 270 PERMIT 9 Break 10 215 100 185 CENTER 10 r TOTALS 1000 0 990 0 990 0 COMMENTS: Cooling Supply Air Temperature: Heating Supply Air Temperature: AC -2, Carrier 48GS-030040501, 40 MBH nput heater 55 DESIGN HEATING CFM 105 ACTUAL HEATING CFM Diffuser # AC -3, 6 Ton DIFFUSER DESIGN PRELIMINARY FINAL VARIANCE MINIMUM ROOM NAME TYPE SIZE AK CFM READING CFM READING CFM % CFM 1 Office South 175 260 195 2 Office North 175 255 190 3 Open Office 195 240 220 4 Open Office 195 250 185 5 Open Office 195 180 200 6 Open Office 195 175 210 7 Open Office 300 220 260 8 Open Office 300 260 270 9 Break 215 100 185 10 f TOTALS 1' r i> [ 1945 1 0 1 1940 r 0 1915 0 COMMENTS: Cooling Supply Air Temperature: Heating Supply Air Temperature: AC -3, Evcon# DBUC-T072N125A, 125MBH Input Heater 52 DESIGN HEATING CFM 120 ACTUAL HEATING CFM AIR BALANCE REPORT P �y: CO P y • PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER M13-063 DATE: 04-08-13 PROJECT NAME: NISSIN TRANSPORT USA SITE ADDRESS: 18436 CASCADE AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: t-11 iuilding (vision 7 Public Works AY 14 0(4 1? Fire Prevention IS Planning Division Structural n Permit Coordinator 1111 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04-09-1.3 Complete Incomplete n Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: LETTER OF COMPLETENESS MAILED: TUES/THURS ROUTING: Please RouteD—ct.Structural Review Required ❑ No further Review. Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 05-07-13 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeopleonter Friendly Page • General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MJR MECHANICAL LLC UBI No. 602976399 Phone 2067146374 Status Active Address Pobox 33326 License No. MJRMEML913R8 Suite/Apt. License Type Construction Contractor City Seattle Effective Date 12/28/2009 State WA Expiration 12/28/2013 Date Zip 98133 Suspend Date County King Specialty 1 Heating/Vent/Air-Conditioning And Refrig (Hvac/R) Business Type Limited Liability Specialty 2 Unused Company Parent Company Business Owner Information Name Role Effective Date Expiration Date RICHEY, MICHAEL JAMES Partner/Member 12/28/2009 DAVIS, GRETCHEN SUZANNE Partner/Member 12/28/2009 Bond Information Page 1 of 1 Bond 1 Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date WESTERN SURETY CO 70847425 12/16/2009 Until Cancelled $6,000.00 12/28/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 1 FARMERS INS EXCHANGE 604786007 12/28/2009 12/28/2013 $1,000,000.00 12/07/2012 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns://fortress.wa.gov/lni/bbip/Print.aspx 04/15/2013 Ducts Up to Ex 6 ton Unit New 20/20 SLSN Duct Drop New 24/24 RAG SECTION LOOKING SOUTH SCALE: 1/8" = 1'-0" Ducts Up to Ex 6 ton Unit New 20/20 SLSN Duct Drop Typkal duct drop Typkal Ceiling diffuser SECTION LOOKING WEST SCALE: 1/8" = 1'-0" FILE COPY Permit No. Flan review approval is subject to errors and ontsslors.. k3 =rc: '` l of construction documents does not a :.lq Pr :.a ltl ..o!ation of any adopted code or ordinance. Receipt of approved Field • and co ns Is a cknowl ed: 3 BY Date: City Of 1Ukwtla BUILDYNG DIVISION REVISIONS No changes shall be made to the scope cf work without prior approval of Tukwila Building Division. ESOT:: I ievlsions will require a new plan submittal anc may include additional plan review fees. ni!NSEPARATE PERMIT REQUIRED FOR; ❑ Mechanical L'� jl,imbin� GiklectrIcal Gas Piping C;y of Tukwila G DIVISION 1 10'0 V Duct drops Ducts Up to Ex 6 tan Unit Nes 20/20 SLSN Duct Drop Nes 24/24 RAG Cap 18 175 75 CFM LI u 195 CFM 195 CFM CFM 0 30 9f& 8 Cap 30 17 \j DdstFp 2.5 ton Unit CFA 17 8 Bdstino 2 ton Unit CFFM 8 1 1 11 OO NORTH 10'0 W Duct drops MECHANICAL FLOOR PLAN SCALE: 1/8" = 1'-0" c> CONSTRUCTION NOTE' RC) EXISTING THERMOSTAT LOCATION, RELOCATED THERMOSTAT LOCATI❑N. NEW ROUND DUCTWORK (UN -INSULATED). MINIM NEW FLEX DUCTWORK, EXISTING.', ROUND DUCTWORK EXISTING RECTANGULAR RUCTWORK MJR MJR Mechanical, LLC PO Box 33326 Shoreline, WA 98133 ph: (206) 714-6374 fax: (206) 533-0628 Contractor's License# MJRMEML913R8 GENERAL NOTES 1 MJR sheetMetal forman to coordinate all facets of this scope of work with G.C, supt. at the start of this project. 2 Rectangular ductwork to be per Smacna 1' construction standards. Ductwork within 5' of equipment to lined with 1' R-4.2 'Johns Manville' Linacoustic duct liner. See drawings for other locations for duct lining and thickness. 3 Round ductwork to be as follows' Concealed' Snaplock with 'Columbia' purchased fittings, Exposed' Spiral wound, with 'Columbia' fittings. Branch ductwork to be the same size as the neck size of the respective diffuser. 4 ROUND DUCT/FITTING 3' thru 8' 9' thru 14` 15' thru 26' SPIRAL GAGE 26 26 24 SNAPLOCK GAGE FITTING$ 26 26 26 24 22 24 5 All concealed ductwork joints are to be sealed with 'Ductmate PROseal' duct sealant. Exposed sections of ductwork and fittings should be sealed with clear cauking Duct tape Is NOT an approved sealant per WSEC, 6 Flex ductwork to be as follows' With -In .Bldg Envelope' R4.2 Insulated flex, Within warehouse' R-8.0 Insulated flex, 7 All duct branches are to have manual volume damper at take off, or where shown on drawings. 8 Ceiling diffusers are to be set up for 4 -way -through unless otherwise noted on drawing. Coordinate exact location of ceiling diffusers with reflected ceiling plan. 9 Ductwork hanging more than 12' below the the concrete deck must be seismicly braced per- Smacna selsmc restraint manual, 10 Existing HVAC units to be reused for this tenant space. Owner or owners service contractor to Insure proper operation of heating, cooling and filtration functions. MJR Mechanical will verify outdoor settings. 11 MJR controls scope of work is limited to relocation of existing programmable thermostats. 12 13 ENERGY CODE COMPLIANCE REQUIREMENTS' This system Is assumed to be In proper working order prior to balance and commissioning. MJR Mechanical wit provide the following' Balance all diffusers and grilles. Measure and record heating supply, return & outside air temperatures when system Is balanced. Check to assure clean filters are In place. MJR to provide owner operating Instructions, MJR sheetmetal foreman shall maintain record drawings showing any deviation from these plans. SHEET NOTES! Existing registers to be removed and duct capped.. Connect existing duct run -out -to new duct. Existing smoke Detector to be relocated to a more accessable location, by others. Remove existing rretrunair grille and patch opening. No Work In This Area. Relocate existing thermostats SCOPE OF WORK MODIFY DUCTWORK FROM EXISTING AC UNITS ADD 6 NEW DIFFUSERS ND 1 NEW RETURN GRILLE RELOCATE 3 THERMOSTAT SENSORS TESTING AND BALANCING . PROJECT DATA STREET ADDRESS 18436 Cascade Ave S, Suite 120 Tukwila, WA 98004 REVIEWED FOR CODE COMPLIANCE APPROVED APR 1 1 2013 A'Y - City of Tukwila DIVISION O LL_ 0 uJ O 0 PROPOSED O N • M 0- Co ♦♦AA ■ u) • A+. vI W co co v CO co co a w 1— DAZE DESCRIPTION PROPERTY MANAGEMENT INFO CBRE CONTACT: GREG COLEMAN ASSESSORS PARCEL NUMBER 7888900030 MECHANICAL CONTRACTOR MJR MECHANICAL, LLC PO BOX 33326 SHORELINE, WA 98133 CONTACT: MIKE RICHEY, 206-714-6374 A\ 4-1-13 ISSUED FOR OWNER REVIEW & PERMIT A A A THIS DRAWING IS THE SOLE PROPERTY OF MJR Mechanical, LLC ANY REPRODUCTION, DUPLICATION, ADDITIONS AND/OR MODIFICATIONS REQUIRE THE WRITTEN APPROVAL OF MJR Mechanical, LLC. PRO,A=CT MANAGER DESIGNED BY MR MR DRAWN BY MR CHECKED BY MR WORK AREA RECEIVED CITY OF TUKWILA APR 0 8 2013 PERMIT CENTER SCALE AS NOTED PROJECT NO. DRAWING 11TLES HVAC PLAN SHEET NUMBER BUILDING PLAN COPYRIGHT CO 2009 MJR MECHANICAL, LLC.