HomeMy WebLinkAboutPermit M13-063 - NISSIN TRANSPORTATION USA - ALTERATION1VISSIN
TRANSPORT USA
18436 CASCADE AV S
M13-063
City mTukwila
•
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: httn://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.:
Address:
7888900030
18436 CASCADE AV S TUKW
Project Name: NISSIN TRANSPORTATION USA
Permit Number:
Issue Date:
Permit Expires On:
M13-063
04/15/2013
10/12/2013
Owner:
Name:
Address:
Contact Person:
Name:
Address:
Email:
EPROPERTY TAX INC DEPT 207
PO BOX 4900 , SCOTTSDALE AZ 85261
MIKE RICHEY
PO BOX 33326 , SHORELINE WA 98133
MIKERICHEY@COMCAST.NET
Contractor:
Name: MIR MECHANICAL LLC
Address: PO BOX 33326 , SEATTLE WA 98133
Contractor License No: MJRMEML913R8
Phone: 206-714-6374
Phone: 206-714-6374
Expiration Date: 12/28/2013
DESCRIPTION OF WORK:
INSTALL NEW TO CONVERT SYSTEM FROM OPEN CEILING CONCEPT TO A NEW T -BAR CEILING,
WITH NEW DUCTWORK, DIFFUSERS AND GRILLES.
Value of Mechanical: $6,000.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
Fees Collected:
$257.06
International Mechanical Code Edition: 2009
Date:
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signature:
Print Name: 1/- \ \f C (1-k c
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
Date: tf[ I s I 1.3
11A14 AC1 Dr; n+nrl• AA _I f. 9A14
PERMIT CONDITIONS
Permit No. M13-063
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center
(206/431-3670).
4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
5: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary
sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other
excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of
this requirement.
7: Manufacturers installation instructions shall be available on the job site at the time of inspection.
8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
'Inn• IIUC_All n
M11 -0R1 Printed: 04-15-2013
• •
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd, Suite 100
Tukwila, WA 98188
htth i'/www_.TilkwiIaWA.gpv
Mechanical Permit No. ( .J- 0 % 3
Project No.
Date Application Accepted:
Date Application Expires:
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION
King Co Assessor's Tax No.: 7888900030
Site Address: 18436 Cascade Ave. S. Suite Number: 120 Floor: 1st
Tenant Name: Nissin Transport USA New Tenant: ® Yes ..No
PROPERTY OWNER
Name: CBRE
Address: 20415-125nd Ave. S. Suite #210
City: Kent State: WA Zip:
CONTACT PERSON — person receiving all project
communication
Name: Mike Richey
Address: PO Box 33326
Address: PO Box 33326
Phone: (206) 714-6374 Fax: (206) 533-0628
City: Shoreline State: WA
Zip: 98133
Phone: (206) 714-6374 Fax: (206)
533-0628
Email: mikerichey2comcast.net
MECHANICAL CONTRACTOR INFORMATION
Company Name: MJR Mechanical
Address: PO Box 33326
City: Shoreline State: WA Zip: 98133
Phone: (206) 714-6374 Fax: (206) 533-0628
Contr Reg No.: MJRMEML913R8 Exp Date: rt. -03
Tukwila Business License No.: (So c _ 0, 9 26 cit
Valuation of project (contractor's bid price): $ lot al)
Describe the scope of work in detail:
Install new to convert system from open ceiling concept to a new T -bar ceiling, with new ductwork. diffusers and grilles.
Use: Residential: New ❑ Replacement ❑
Commercial: New Replacement ❑
Fuel Type: Electric ❑ Gas
Other:
H:\ Applications\Forms-Applications On Line\2011 Applications \Mechanical Permit Application Revised 8-9-1 Ldocx
Revised: August 2011
bh
Page 1 of 2
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
6
Floor furnace
Suspended/wall/floor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
6
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
Unit Type
Qty
Fire damper
Diffuser
6
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
1 HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNE /7' AU O ED AGENT:
Signature:
Print Name:
Mailing Address:
v F /(L\ckkt
m'7\ 1"53g,
H:\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Date: 'ft 5 ( 5
Day Telephone: A. °Lo 7 (( - C:1/
T
5�1 o@.EL t,� F ,mak 6 133
City State Zip
Page 2 of 2
•
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
Parcel No.: 7888900030
Address: 18436 CASCADE AV S TUKW
Suite No:
Applicant: NISSIN TRANSPORT USA
RECEIPT
Permit Number: M13-063
Status: PENDING
Applied Date: 04/08/2013
Issue Date:
Receipt No.: R13-01234
Initials:
User ID:
WER
1655
Payment Amount: $257.06
Payment Date: 04/08/2013 08:42 AM
Balance: $0.00
Payee: MJR MECHANICAL
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 174204
ACCOUNT ITEM LIST:
Description
257.06
Account Code Current Pmts
MECHANICAL - NONRES
PLAN CHECK - NONRES
000.322.102.00.00 205.65
000.345.830 51.41
Total: $257.06
,a,...• oo..einf_na
Printed: 04-08-2013
-450
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION C�
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 431-2451 ;
imi3-o63
Project: �V
tj,ss, TrAAspoir
Type o .Inspection:
;,J �'�- Ake
Add �s: 3� (
Date Called:
Special Instructions:
Date Wanted:
`` (3
f
f---;
p.m.
Requester:
Phone No:
Approved per applicable codes. El Corrections required prior to approval.
COMMENTS:
f PO; 1A(---7)
Inspecto
OLKO
k A
Date:
i3
u�.
r7REINSPECTION FEE REQUIRED. Pri r to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila: WA 98188 (206) 431-367
/01j(
k.
Permit Inspection Request Line (206) 431-2451
AA(3-0G3
Project: ,
Al , S5 , n `HAAS,
Type of ICspection:
• t-1 SP A- L J e (J 1
Address:
/ �31� 1.�:5cMe
Date Called:
Special Instructions:
Date Wanted n s-! a.m.'.p.
_
(i m.
L
Requester:
-
hoyn. N� l 1 -(05)74
Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
> Of- 4 PACe gear-- (
V
0 K— 11-) v Cott- = A .: Iii J i
o f
D
t
Inspi'ctor:
r
ck,-A
Date4 ` S - /3
1
n REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be
paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 q (206) 431-3670
Permit Inspection Request Line (206) 431-2451
A4(3 -003
Project:.
Typ of Inspection: /
Address:
i X43 g (kJ
Date Called:
�
Special Instructions:
Date Wanted:. % (a,m1
Requester:
Phone No:
j(Q——7(-4 -0291
1
Approved per applicable codes.
COMMENTS:
Corrections required prior to approval.
i
E
A
r I;
Insptdctor:
v � i
n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
MJR Mechanical
PROJECT
UNIT NO.
13 ,c9(0_3
Date: 4/29/2013
AIR DISTRIBUTION - OUTLET TEST REPORT Technician: Richey
Nissin Transportation USA
Report By:
JOB NO.
Test Date: 04/27/13
Diffuser
#
AC -1 2 Ton
DIFFUSER
DESIGN
PRELIMINARY
FINAL
VARIANCE
MINIMUM
ROOM NAME
TYPE
SIZE
AK
CFM
READING
CFM
READING CFM
%
CFM
1
Comer Office
1
10
400
375
175
375
260
2
Office
10
Office North
400
450
450
255
3
Open Office SW
8
3
250
285
2�ECFIVEp
195
4
Open Office SE
220
8
250
Open Office
245
CI7' 5OF
TUKWILA
195
5
250
185
5
Open Office
6
180
200
6
Open Office
7
195
175
210
7
APR ,�
0 2u13
8
300
220
260
8
Open Office
9
300
260
270
PERMIT
9
Break
10
215
100
185
CENTER
10
TOTALS
800
0 0
825
0
825
0
COMMENTS:
Cooling Supply Air Temperature:
Heating Supply Air Temperature:
AC -1, Carrier 48GS-0180040301, 40 MBH Input Gas heater
57 DESIGN HEATING CFM
105 ACTUAL HEATING CFM
Diffuser
#
AC -2, 2-1/2 Ton
DIFFUSER
DESIGN
PRELIMINARY
FINAL
VARIANCE
MINIMUM
ROOM NAME
TYPE
SIZE
AK
CFM
READING
CFM
READING CFM
%
CFM
1
Open Office NW
1
8
250
260
175
260
260
2
Open Office NE
8
Office North
250
200
200
255
3
Open Office SW
8
3
250
285
2�ECFIVEp
195
4
Open Office SE
220
8
250
Open Office
245
CI7' 5OF
TUKWILA
195
5
250
185
5
Open Office
195
180
200
6
Open Office
7
195
175
210
7
APR ,�
0 2u13
8
300
220
260
8
Open Office
9
300
260
270
PERMIT
9
Break
10
215
100
185
CENTER
10
r TOTALS
1000
0
990
0
990
0
COMMENTS:
Cooling Supply Air Temperature:
Heating Supply Air Temperature:
AC -2, Carrier 48GS-030040501, 40 MBH nput heater
55 DESIGN HEATING CFM
105 ACTUAL HEATING CFM
Diffuser
#
AC -3, 6 Ton
DIFFUSER
DESIGN
PRELIMINARY
FINAL
VARIANCE
MINIMUM
ROOM NAME
TYPE
SIZE
AK
CFM
READING
CFM
READING CFM
%
CFM
1
Office South
175
260
195
2
Office North
175
255
190
3
Open Office
195
240
220
4
Open Office
195
250
185
5
Open Office
195
180
200
6
Open Office
195
175
210
7
Open Office
300
220
260
8
Open Office
300
260
270
9
Break
215
100
185
10
f TOTALS
1'
r
i>
[ 1945
1 0
1 1940 r 0
1915
0
COMMENTS:
Cooling Supply Air Temperature:
Heating Supply Air Temperature:
AC -3, Evcon# DBUC-T072N125A, 125MBH Input Heater
52 DESIGN HEATING CFM
120 ACTUAL HEATING CFM
AIR BALANCE REPORT
P �y: CO P y •
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER M13-063
DATE: 04-08-13
PROJECT NAME: NISSIN TRANSPORT USA
SITE ADDRESS: 18436 CASCADE AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # After Permit Issued
DEPARTMENTS: t-11
iuilding (vision 7
Public Works
AY 14 0(4 1?
Fire Prevention IS Planning Division
Structural
n Permit Coordinator 1111
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04-09-1.3
Complete
Incomplete
n
Not Applicable
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
LETTER OF COMPLETENESS MAILED:
TUES/THURS ROUTING:
Please RouteD—ct.Structural Review Required ❑ No further Review. Required
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
Approved Approved with Conditions
Notation:
REVIEWER'S INITIALS: DATE:
DUE DATE: 05-07-13
Not Approved (attach comments) n
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections:
Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Documents/routing slip.doc
2-28-02
Contractors or Tradespeopleonter Friendly Page
•
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name MJR MECHANICAL LLC UBI No. 602976399
Phone 2067146374 Status Active
Address Pobox 33326 License No. MJRMEML913R8
Suite/Apt. License Type Construction Contractor
City Seattle Effective Date 12/28/2009
State WA Expiration 12/28/2013
Date
Zip 98133 Suspend Date
County King Specialty 1 Heating/Vent/Air-Conditioning And Refrig
(Hvac/R)
Business Type Limited Liability Specialty 2 Unused
Company
Parent
Company
Business Owner Information
Name
Role
Effective Date
Expiration Date
RICHEY, MICHAEL JAMES
Partner/Member
12/28/2009
DAVIS, GRETCHEN SUZANNE
Partner/Member
12/28/2009
Bond Information
Page 1 of 1
Bond
1
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
WESTERN SURETY CO
70847425
12/16/2009
Until Cancelled
$6,000.00
12/28/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
1
FARMERS INS
EXCHANGE
604786007
12/28/2009
12/28/2013
$1,000,000.00
12/07/2012
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
httns://fortress.wa.gov/lni/bbip/Print.aspx 04/15/2013
Ducts Up to Ex 6 ton Unit
New 20/20 SLSN Duct Drop
New 24/24 RAG
SECTION LOOKING SOUTH
SCALE: 1/8" = 1'-0"
Ducts Up to Ex 6 ton Unit
New 20/20 SLSN Duct Drop
Typkal duct drop
Typkal Ceiling diffuser
SECTION LOOKING WEST
SCALE: 1/8" = 1'-0"
FILE COPY
Permit No.
Flan review approval is subject to errors and ontsslors..
k3 =rc: '` l of construction documents does not a :.lq Pr :.a
ltl ..o!ation of any adopted code or ordinance. Receipt
of approved Field • and co ns Is a cknowl ed:
3
BY
Date:
City Of 1Ukwtla
BUILDYNG DIVISION
REVISIONS
No changes shall be made to the scope
cf work without prior approval of
Tukwila Building Division.
ESOT:: I ievlsions will require a new plan submittal
anc may include additional plan review fees.
ni!NSEPARATE PERMIT
REQUIRED FOR;
❑ Mechanical
L'� jl,imbin�
GiklectrIcal
Gas Piping
C;y of Tukwila
G DIVISION
1
10'0 V Duct drops
Ducts Up to Ex 6 tan Unit
Nes 20/20 SLSN Duct Drop
Nes 24/24 RAG
Cap
18
175
75
CFM
LI u
195
CFM
195
CFM
CFM
0
30
9f&
8
Cap
30
17
\j
DdstFp 2.5 ton Unit
CFA
17
8
Bdstino 2 ton Unit
CFFM
8
1
1
11
OO
NORTH
10'0 W Duct drops
MECHANICAL FLOOR PLAN
SCALE: 1/8" = 1'-0"
c>
CONSTRUCTION NOTE'
RC)
EXISTING THERMOSTAT LOCATION,
RELOCATED THERMOSTAT LOCATI❑N.
NEW ROUND DUCTWORK (UN -INSULATED).
MINIM NEW FLEX DUCTWORK,
EXISTING.', ROUND DUCTWORK
EXISTING RECTANGULAR RUCTWORK
MJR
MJR Mechanical, LLC
PO Box 33326
Shoreline, WA 98133
ph: (206) 714-6374 fax: (206) 533-0628
Contractor's License# MJRMEML913R8
GENERAL NOTES
1 MJR sheetMetal forman to coordinate all facets of this scope of work with G.C,
supt. at the start of this project.
2 Rectangular ductwork to be per Smacna 1' construction standards. Ductwork
within 5' of equipment to lined with 1' R-4.2 'Johns Manville' Linacoustic duct liner.
See drawings for other locations for duct lining and thickness.
3 Round ductwork to be as follows'
Concealed' Snaplock with 'Columbia' purchased fittings,
Exposed' Spiral wound, with 'Columbia' fittings.
Branch ductwork to be the same size as the neck size of the respective
diffuser.
4
ROUND
DUCT/FITTING
3' thru 8'
9' thru 14`
15' thru 26'
SPIRAL
GAGE
26
26
24
SNAPLOCK
GAGE FITTING$
26 26
26 24
22 24
5 All concealed ductwork joints are to be sealed with 'Ductmate PROseal' duct
sealant. Exposed sections of ductwork and fittings should be sealed with clear
cauking Duct tape Is NOT an approved sealant per WSEC,
6 Flex ductwork to be as follows'
With -In .Bldg Envelope' R4.2 Insulated flex,
Within warehouse' R-8.0 Insulated flex,
7 All duct branches are to have manual volume damper at take off, or where
shown on drawings.
8 Ceiling diffusers are to be set up for 4 -way -through unless otherwise noted on
drawing. Coordinate exact location of ceiling diffusers with reflected ceiling plan.
9 Ductwork hanging more than 12' below the the concrete deck must be seismicly
braced per- Smacna selsmc restraint manual,
10 Existing HVAC units to be reused for this tenant space. Owner or owners service
contractor to Insure proper operation of heating, cooling and filtration
functions. MJR Mechanical will verify outdoor settings.
11 MJR controls scope of work is limited to relocation of existing programmable
thermostats.
12
13
ENERGY CODE COMPLIANCE REQUIREMENTS'
This system Is assumed to be In proper working order prior to
balance and commissioning. MJR Mechanical wit provide the following'
Balance all diffusers and grilles.
Measure and record heating supply, return & outside air
temperatures when system Is balanced.
Check to assure clean filters are In place.
MJR to provide owner operating Instructions,
MJR sheetmetal foreman shall maintain record drawings showing
any deviation from these plans.
SHEET NOTES!
Existing registers to be removed and duct capped..
Connect existing duct run -out -to new duct.
Existing smoke Detector to be relocated to a more accessable
location, by others.
Remove existing rretrunair grille and patch opening.
No Work In This Area.
Relocate existing thermostats
SCOPE OF WORK
MODIFY DUCTWORK FROM EXISTING AC UNITS
ADD 6 NEW DIFFUSERS ND 1 NEW RETURN GRILLE
RELOCATE 3 THERMOSTAT SENSORS
TESTING AND BALANCING .
PROJECT DATA
STREET ADDRESS
18436 Cascade Ave S, Suite 120
Tukwila, WA 98004
REVIEWED FOR
CODE COMPLIANCE
APPROVED
APR 1 1 2013
A'Y -
City of Tukwila
DIVISION
O
LL_
0
uJ
O
0
PROPOSED
O
N
• M
0- Co
♦♦AA ■
u)
• A+.
vI
W co
co
v CO
co
co
a
w
1—
DAZE DESCRIPTION
PROPERTY MANAGEMENT INFO
CBRE
CONTACT: GREG COLEMAN
ASSESSORS PARCEL NUMBER
7888900030
MECHANICAL CONTRACTOR
MJR MECHANICAL, LLC
PO BOX 33326
SHORELINE, WA 98133
CONTACT: MIKE RICHEY, 206-714-6374
A\
4-1-13 ISSUED FOR OWNER
REVIEW & PERMIT
A
A
A
THIS DRAWING IS THE SOLE PROPERTY OF MJR
Mechanical, LLC ANY REPRODUCTION, DUPLICATION,
ADDITIONS AND/OR MODIFICATIONS REQUIRE THE WRITTEN
APPROVAL OF MJR Mechanical, LLC.
PRO,A=CT MANAGER DESIGNED BY
MR MR
DRAWN BY
MR
CHECKED BY
MR
WORK AREA
RECEIVED
CITY OF TUKWILA
APR 0 8 2013
PERMIT CENTER
SCALE
AS NOTED
PROJECT NO.
DRAWING 11TLES
HVAC PLAN
SHEET NUMBER
BUILDING PLAN
COPYRIGHT CO 2009 MJR MECHANICAL, LLC.