HomeMy WebLinkAboutPermit M13-064 - DHS - OPS CENTER - REPLACE ROOF TOP UNITDHS - OPS CENTER 12500 TUKWILA INTERNATIONAL BL M13-064 City ohukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 7340600602 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Project Name: DHS - OPS CENTER Permit Number: M13-064 Issue Date: 04/15/2013 Permit Expires On: 10/12/2013 Owner: Name: INTERNATIONAL GATEWAY EAST LLC Address: 12201 TUKVVILA INTL BLVD 4TH FLR , SEATTLE WA 98168 Contact Person: Name: PAUL YOUNG Address: 7717 DETROIT AV SW , SEATTLE WA 98106 Email: PAUL.YOUNG@MACMILLER.COM Contractor: Name: MACDONALD/MILLER FAC SOL INC Address: PO BOX 47983 , SEATTLE, WA 98106 Contractor License No: MACDOFS980RU Phone: 206-768-4230 Phone: 206-768-4180 Expiration Date: 01/03/2015 DESCRIPTION OF WORK: INSTALL (1) NEW PACKAGED ROOF TOP HEAT PUMP, ADD (3) GRD'S, MISCELLANEOUS DUCTWORK. MISCELLANEOUS REFRIGERATION AND GAS LINES PER PLAN. Value of Mechanical: $10,600.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Fees Collected: $318.31 International Mechanical Code Edition: 2009 Permit Center Authorized Signature: /.=j �i��vvL / � l_ Date: 04(// I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Date: Print Name: ] ,Z- ) /491 C S --P This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 6A4 AGA 0.4...4,..4• AA 1G OM1 PERMIT CONDITIONS Permit No. M13-064 1: ***BUILDING DEPARTMENT CONDmONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Readily accessible access to roof mounted equipment is required. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-064 Printed: 04-15-2013 • CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No.:: Date Application Accepted::' Date; Application Expires:, For office; use only), MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 7340600602 Site Address: 12500 Intern'l Blvd Tukwila, WA 98168 Suite Number: 400 Floor: 4 Tenant Name: b S O Ps Gets -- PROPERTY OWNER Name: INTERNATIONAL GATEWAY EAST LLC Address: 12500 International Blvd City: TUKWILA State: WA Zip: 98168 CONTACT PERSON - person receiving all project communication Name: PAUL YOUNG Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-4230 Fax: (206) 768-4231 Email: paul.young@macmiller.com New Tenant: ❑ Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: MACDONALD MILLER Address: 7717 DETROIT AVE SW City: SEATTLE State: WA Zip: 98106 Phone: (206) 768-4278 Fax: (206) 768-4279 Contr Reg No.: MACDOFS980RU Exp Date: 12/31/2013 Tukwila Business License No.: BUS -0100868 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: INSTALL (1) NEW PACKAGED ROOF TOP HEAT PUMP, ADD (3) GRD'S, MISC DUCTWORK. MISC REFER AND GAS LINES PER PLAN. 10,600 Use: Residential: New ❑ Replacement ❑ Commercial: New 121 Replacement 0 Fuel Tyne: Electric m Gas Other: H:\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 } Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 3 Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system 1 Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm 3 Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct 1 Incinerator — domestic Incinerator — comm/industrial • Unit Type Qty Fire damper Diffuser 3 Thermostat Wood/gas stove Emergency generator Other mechanical equipment 1 Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING O UTHORIZED - ENT: Signature: Date: 04/04/2013 Print Name: ARLA DOLL Day Telephone: (206) 768-4278 Mailing Address: 7717 DETROIT AVE SW H:\Applicattons\Forms-Applications On Lme\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh SEATTLE WA 98106 City State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 7340600602 Permit Number: M13-064 Address: 12500 TUKWILA INTERNATIONAL BL TUKW Status: PENDING Suite No: Applied Date: 04/08/2013 Applicant: DHS - OPS CENTER Issue Date: Receipt No.: R13-01238 Initials: WER User ID: 1655 Payment Amount: $318.31 Payment Date: 04/08/2013 11:20 AM Balance: $0.00 Payee: MACDONALD MILLER FACILITY SOLUTIONS INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 3584 318.31 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 254.65 000.345.830 63.66 Total: $318.31 Printed• na-nR-2M3 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. /' CITY OF TUKWILA BUILDING DIVISION (� 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Mf3-061 Projectn ti____ t � T kgt 't' . Inspection: t-A - -S i Rcx.) Address.Q---�.E& <.L_ Dd:ate Ca LA I leM ' J AR.P(�j& Special Instructions: Date Wanted:r Wim. Cj -- l/ - p.m. i—r Requester:- Ph7one No: j' _ 5 iQ j 1417 Approved per applicable codes. Corrections required prior to approval. COMMENTS: • 6 i., &An _�x P 1\.f . , - rt 11`-- . v CA 7: ' Y . o (%.._ p -P -A f. t. r2(C5,) . "ie' S ( .T ,-%.) . f . 0-PJotAt (.. lA-- A(- f . e & 1 In pectora J V \ REINSPECTION FEE REQUIRED. Pri?r to next•inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. Dat PLAN REVIEW/ PERMIT GO 1YING SLIP ACTIVITY NUMBER: M13-064 DATE: 04-08-13 PROJECT NAME: DHS OPS CENTER SITE ADDRESS: 12500 TUKWILA INTERNATIONAL BL - SUITE 400. X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # After Permit Issued DEPARTMENTS:t1_ 1t--1'3 4din?nsion 1111 Public Works n N t irF a Prevention Structural ❑ Planning Division Permit Coordinator v DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 04-09-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: • LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: ❑ No further Review Required DATE: n APPROVALS OR CORRECTIONS: Approved I1 Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 05-07-13 Not Approved (attach comments) I I Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Peter Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LaI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MACDONALD/MILLER FAC SOL INC UBI No. 602254260 Phone 2067684180 Status Active Address Po Box 47983 License No. MACDOFS980RU Suite/Apt. License Type Construction Contractor City Seattle State WA Zip 98106 County King Business Type Corporation Parent Company Effective Date 12/31/2002 Expiration Date 1/3/2015 Suspend Date Specialty 1 General Specialty 2 Unused Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status DIVC01"988RC DIVCO INCORPORATION Construction Contractor General Unused 12/3/2002 11/7/2014 Active LINFOAR980QG LINFORD AIR & REFRIGERTN INC Construction Contractor General Unused 11/7/2002 11/7/2004 Archived ENCOMMS984CA ENCOMPASS MECHANICAL SERVICES Construction Contractor General Unused 2/1/2002 2/1/2004 Archived MACDOMR026RU MACDONALD MILLER RSDNTL INC Construction Contractor General Unused 12/31/1998 12/31/2001 Archived DIVC01"031L4 DIVCO INC Construction Contractor General Unused 6/24/1997 8/1/2003 Archived MACDOMR076oPMACDONALDMILLER RESIDENTIAL Construction Contractor General Unused 9/17/1993 12/30/1998 Archived DIVCOEC188LC DIVCO ENERGY CONTROL COMPANY Construction Contractor General Unused 6/3/1982 5/26/1997 Archived MACDOM"248J9 MACDONALD MILLER CO Construction Contractor General Unused 4/29/1976 2/1/2002 Archived Business Owner Information Name Role Effective Date Expiration Date GOUGH, DAVID ANTHONY Director 12/29/2010 HOEL, STEPHANIE W Member 05/14/2010 SIMONDS, DERRICK R President 05/14/2010 WEBSTER, MARK E Vice President 05/14/2010 TURLEY, DOUGLAS Chief Executive Officer 02/13/2008 01/04/2011 TURLEY, DOUGLAS Chief Operating Officer 02/13/2008 01/04/2011 SIGMUND, FREDRIC President 12/31/2002 01/04/2011 HACK, RICHARD Secretary 02/13/2008 01/04/2011 KOPET, TYLER Treasurer 12/31/2002 01/04/2011 LOVELY, STEVE C Vice President 12/31/2002 01/04/2011 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 LIBERTY MUTUAL INS CO 023006951 12/11/2002 Until Cancelled $12,000.00 12/31/2002 Assignment of Savings Information No records found for the previous 6 year period httns://fortress.wa.gov/lni/bbin/Print.asnx 04/15/2013 0 I 0 criM M i J° 3 c O c w 0 0 m 0 N 0 a to m 1 Thursday, April 04, 2013 9:06:06 NG GENERAL NOTES.. .:. FITTIN PIPING MATERIAL SCHEDULE: PIPING SIZE MATERIAL JOINT REFRIGERATION 1 1/8" - 4-1/8" COPPER TUBE, ACR BRAZED PIPING INSULATION SCHEDULE PIPING PIPE INSULATION INSULATION _ TYPE - SIZE TYPE THICKNESS I CONDUCTIVITY RANGE REFRIGERATION SUCTION 1/8"-7/8" ARMAFLEX 1" 0.22 - 0.28 _- 1-1/8" + ARMAFLEX 1-1/2" 1 0.22 - 0.28 REFRIGERATION MIXED (DOWNSTREAM OF TXV) I 1/8" - 7/8" j I ARMAFLEX 1" j 0.22 - 0.28 - ALL PIPING INSULATION AND COVERINGS SHALL HAVE AN ASTM FLAME SPREAD RATING OF 25 OR LESS AND AN ASTM SMOKE DEVELOPED RATING OF 50 OR LESS. - ELASTOMERIC INSULATIONS WHICH MEET THESE RATINGS MAY BE USED AS A SUBSTITUTE FOR FIBERGLASS. - PROVIDE A VAPOR BARRIER COVERING ON ALL CHILLED WATER PIPING AND COIL CONDENSATE PIPING INSULATION. - PROVIDE A COVERING FOR ALL FIBERGLASS INSULATION WITHIN THE BUILDING. - PROVIDE A VINYL JACKET FOR ALL INSULATION EXPOSED TO SIGHT WITHIN THE BUILDING EXCEPT MECHANICAL ROOMS. - PROVIDE REMOVABLE LACED INSULATION PAD OVER ALL CONTROL VALVES, WHERE NOT LOCATED WITHIN A MECHANICAL ROOM. - PROVIDE ALUMINUM JACKET ON ALL INSULATED PIPING OUTSIDE BUILDING. - AT PIPE HANGERS PROVIDE RIGID INSULATION BETWEEN PIPE AND HANGER. 1. THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE MECHANICAL CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2009 IBC, IMC, AND UPC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. / 3. ALL PIPE SIZES NOTED ON DRAWINGS ARE MINIMUMS. 4. SLOPE ALL INDIRECT DRAINS AT 2% UNLESS OTHERWISE NOTED ON DRAWINGS. OBTAIN APPROVAL FROM CODE AUTHORITY BEFORE INSTALLING PIPING AT LESS THAN 2% (EVEN IF LESSER SLOPE IS INDICATED ON DRAWINGS). 5. HANGERS AND SUPPORTS FOR PIPING SHALL BE IN ACCORDANCE WITH THE 2009 IMC AND IBC AS AMENDED BY THE STATE OF WASHINGTON AND LOCAL AUTHORITIES. 6. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 7. PROVIDE CHROME PLATE ESCUTCHEON PLATES AT ALL EXPOSED WALL AND CEILING PENETRATIONS. 8. PROVIDE SHUT-OFF VALVES AT ALL EQUIPMENT CONNECTIONS. 9. PROVIDE UNION, GROOVED OR FLANGED CONNECTION AT EQUIPMENT FOR FUTURE REMOVAL AND SERVICING. 10. FOR CONDENSATE PIPING PROVIDE TRAPS WITH A MINIMUM SEAL 2" GREATER THAN THE FAN OPERATING STATIC PRESSURE AT ALL COOLING COIL CONNECTIONS. 11. PROVIDE MINIMUM 1" AIR BREAK FOR ALL CONDENSATE PIPE TERMINATIONS AT DRAINS. 12. PROVIDE DIELECTRIC CONNECTIONS BETWEEN DISSIMILAR METALS. 13. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE MECHANICAL CONTRACTOR. COORDINATE ELECTRICAL SUPPLY FOR HEAT TRACE WITH ELECTRICAL CONTRACTOR. NOTES: 1. DISCONNECT BY ELECTRICAL. 2. UNIT MOUNTED ON ROOFED IN SLEEPERS BY ROOFING CONTRACTOR. 3. UNIT PLACEMENT BASED ON RESULTS FROM X-RAYING PT SLAB. 4. 100% ECONOMIZER IS NOT REQUIRED PER 2009-WSEC SECTION 1433 EXCEPTION 1. UNIT NO. MFG & MODEL NO. COOLING MBH TOTAL SENS HEATING MBH CFM ESP IU -401 TRANE GAM5A0B30 31.6 23.30 18.2 750 0.4 FAN HP 1/3 OA CFM ELECTRICAL V/PH 100 208/1 AUX HTR KW 3.6 FLA WT LBS NOTES 2.8 160 NEW, 1-10 NOTES: 1. COOLING CAPACITIES ARE BASED ON ASSOCIATED OU AND 80°EDB, 67°EWB, 95° AMBIENT. 2. HEATING CAPACITY BASED ON ASSOCIATED OU AND 70°F EDB AND 17° AMBIENT. 3. ELECTRICAL TO PROVIDE DISCONNECT. 4. W/ SINGLE POINT POWER CONNECTION. 5. FILTER BY MC, SIZE 20X20X1, QUANTITY (1), MAX INITIAL PRESSURE DROP 0.1" WC. 6. R -410A REFRIGERANT. GAS LINE 3/4" AND LIQUID LINE 3/8". BRAZE CONNECTION. 7. 100% ECONOMIZER IS NOT REQUIRED PER 2009-WSEC SECTION 1433 EXCEPTION 1. 8. WALL MOUNTED, 7 -DAY PROGRAMMABLE T -STAT PROVIDED AND INSTALLED BY MC. 9. MIXING BOX, MOTORIZED DAMPERS, ACTUATORS, AND BALANCING DAMPERS BY MC. 10. CONDENSATE PUMP BY MC. POWER BY ELECTRICAL. ABBV FULL NAME ABBV FULL NAME ABBV A AC AFF AL BDD BOB BOD BOTT BTU BTUH BWG BWR C CAP CC CFM CHWR CHWS COMB CONN CWR CWS DB DIFF DMPR DN EC EGC EER ELEV EMS COMPRESSED AIR LINE AIR CONDITIONING UNIT ABOVE FINISHED FLOOR ALUMINUM BACKDRAFT DAMPER BOTTOM OF BEAM BOTTOM OF DUCT BOTTOM BRITISH THERMAL UNITS BRITISH THERMAL UNITS PER HOUR BOTTOM WALL GRILLE BOTTOM WALL REGISTER CONDENSATE CAPACITY CONTROLS CONTRACTOR CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY COMBUSTION `CONNECT CONDENSER WATER RETURN CONDENSER WATER SUPPLY DUCT BOARD DIFFUSER DAMPER DOWN ELECTRICAL CONTRACTOR EGGCRATE ENERGY EFFICIENCY RATIO ELEVATION ENERGY MANAGEMENT SYSTEM ESP EXH EXTR FAC FD FLA FOB FOT FSD G GALV GC GPM GR GWB HG HP HWR HWS ID INT LIQ M -M MBH MC MCA MD MIN MT MUA NOM EXTERNAL STATIC PRESSURE EXHAUST EXTRACTOR FIRE ALARM CONTRACTOR FIRE DAMPER FULL LOAD AMPS FLAT ON BOTTOM FLAT ON TOP FIRE SMOKE DAMPER GAS LINE GALVANIZED GENERAL CONTRACTOR GALLONS PER MINUTE GRILLE GYPSUM WALL BOARD HOT GAS LINE - HORSE POWER HOT WATER RETURN HOT WATER SUPPLY INSIDE DIMENSION INTERLOCK LIQUID LINE MACDONALD-MILLER ONE THOUSAND BTUH MECHANICAL CONTRACTOR MINIMUM CIRCUITAMPACITY MOTORIZED DAMPER MINIMUM MOUNT MAKE-UP AIR NOMINAL OSA OBD OD RA REG REQ'D ( RIO SA SCD SD SL SM SP SS SSSC STL SUC SUSP TSTAT TC TOD TOS TV TWG TWR TYP UNO VD VFD 0 FULL NAME OUTSIDE AIR OPPOSED BLADE DAMPER OUTSIDE DIMENSION RETURN AIR REGISTER (GRILLE WITH DAMPER) REQUIRED ROUGH IN ONLY SUPPLY AIR SMOKE CONTROL DAMPER SMOKE DAMPER SOUND LINING SHEET METAL STATIC PRESSURE START/STOP SOLID STATE SPEED CONTROLLER STEEL SUCTION LINE SUSPENDED THERMOSTAT TEMPERATURE CONTROL TOP OF DUCT TOP OF STEEL TURN VANES TOP WALL GRILLE TOP WALL REGISTER TYPICAL UNLESS NOTED OTHERWISE VOLUME DAMPER VARIABLE FREQUENCY DRIVE VOLTAGE PHASE & DUCT DIAMETER E DESCRIPTION SYMBOL DESCRIPTION SYMBOL BARE SHEETMETAL 14x12 ROUND SHEETMETAL WRAPPED W/ INSULATION (2") 120W SOUNDLINE SHEETMETAL (1" LINING) 14x12SL CLEANROOM QUALITY DUCTWORK 14x12C SHEETMETAL WRAPPED W/ INSULATION (2") 14x12W BARE FLAT OVAL SHEETMETAL 14x120 BARE ROUND SHEETMETAL 120 FLAT OVAL FLAT SHEETMETAL W/ INSULATION (2") 14x120W EXPOSED QUALITY SHEETMETAL 14x12Q DUCTBOARD (1" FIBERGLASS) 14x12DB EXAMPLE OF NEW 14x12 EXAMPLE OF NOT IN CONTRACT (NIC) 14x12 EXAMPLE OF DEMO FLEX DUCT EXAMPLE OF EXISTING 14X12 FLEX CONNECTOR 3 SYMBOL MANUFACTURER & MODEL NUMBER SIZE TYPE NOTES OSIZE CFM PRICE SMCD AS NOTED T -BAR LAY -IN MODULAR CORE DIFFUSER M -M METAL EGGCRATE 12/24 RETURN/EXH N M -M METAL EGGCRATE 24/24 RETURN/EXH SYMBOL DESCRIPTION -POWERED NOTES SYMBOL DESCRIPTION -NON POWERED NOTES MOTORIZED CONTROL DAMPER -LOW VELOCITY GREENHECK MD -1 M VCD-23 OR EQUAL. I-- VOLUME DAMPER: SHOP FABRICATED, W/LOCKING QUADRANT. 1,2 NOTES: 1. ACTUATOR BY MECHANICAL CONTRACTOR, WIRING BY ELECTRICAL CONTRACTOR 2. DAMPER FAILS CLOSED SITE S 126TH ST S 128TH ST VICINITY MAP NO SCALE SEPARATE PERMIT REQUIRED FOR: D Me banical EV8ectrical (umbing as Piping City of Tukwila E=1:=_E'iNG DIVISION HVAC GENERAL NOTE THESE PLANS ARE SCHEMATIC AND DO NOT SHOW EXACT ROUTING OR EVERY OFFSET WHICH MAY BE REQUIRED. THE HVAC CONTRACTOR IS TO COORDINATE WITH ALL OTHER TRADES AND IS TO VERIFY ALL CLEARANCES BEFORE COMMENCING WORK. 2. MATERIALS, METHODS, AND INSTALLATION SHALL COMPLY WITH THE PROVISIONS OF THE 2009 EDITIONS OF THE INTERNATIONAL MECHANICAL CODE, INTERNATIONAL BUILDING CODE, INTERNATIONAL FIRE CODE AND STATE AND LOCAL CODES AND ORDINANCES. 3. DUCT CONSTRUCTION AND HANGING SHALL COMPLY WITH CHAPTER 6 OF THE 2009 IMC AND WITH CURRENT SMACNA STANDARDS. EARTHQUAKE BRACE ALL DUCTS 28" DIA AND LARGER WHICH ARE SUSPENDED MORE THAN 12" BELOW STRUCTURAL SYSTEM. 4. JOINTS OF MEDIUM AND HIGH VELOCITY DUCT SYSTEMS SHALL BE SEALED WITH GASKETS OR LISTED MASTIC TYPE DUCT SEALANT. 5. DUCTS SHALL BE INSULATED AS INDICATED ON PLANS, PER 2009 WSEC. - DUCT WRAP, WHERE INDICATED, SHALL BE 1 1/2" 0175 LB/CU FT FIBERGLASS DUCT INSULATION WITH A FACTORY APPLIED REINFORCED ALUM. FOIL VAPOR BARRIER (R-4.2 MIN.). - SOUND LINING, WHERE INDICATED, SHALL BE 1" 1.5 LB/CU FT FIBERGLASS DUCT LINING COATED TO PREVENT FIBER EROSION AT VELOCITIES UP TO 6000 FPM (R-4.2 MIN.). - DUCT BOARD, WHERE INDICATED, SHALL BE 1" RIGID FRK FACED El 475 FIBERGLASS DUCT BOARD SYSTEM, UL 181 LISTED AS A CLASS 1 AIR DUCT (R-4.3 MIN.). AIR DUCT (R-4.3 MIN.). 6. FLEX DUCTS SHALL CONSIST OF A REINFORCED VAPOR BARRIER, 1 1/2" FIBERGLASS INSULATION, AND NON -PERFORATED INTERIOR LINER WITH WIRE HELIX. DUCT SHALL BE A UL 181 LISTED CLASS 1 AIR DUCT. FLEX DUCTS SHALL ONLY BE USED WHERE SHOWN AND SHALL NOT EXCEED 12' IN LENGTH UNLESS NOTED OTHERWISE. 7. PROVIDE EARTHQUAKE RESTRAINT FOR HVAC EQUIPMENT IN ACCORDANCE WITH SECTION 1613 OF THE 2009 IBC. 8. PROVIDE FIRE DAMPERS, SMOKE DAMPERS AND FIRE/SMOKE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.5 OF THE 2009 SBC. PROVIDE CEILING FIRE DAMPERS WHERE INDICATED ON PLANS AND AS REQUIRED BY SECTION 716.6.2 OF THE 2009 IBC. INSTALL FIRE DAMPERS SMOKE DAMPERS AND FIRE/SMOKE DAMPERS IN ACCORDANCE WITH THE MANUFACTURERS INSTRUCTIONS, THE TERMS OF THEIR LISTING, AND THE REQUIREMENTS OF THE CODE. 9. PIPING PENETRATIONS OF FIRE RATED WALLS OR FLOORS SHALL BE SLEEVED AND FIRE STOPPED WITH LISTED MATERIALS SO AS TO MAINTAIN THE INTEGRITY AND RATING OF THE FLOOR OR WALL. 10. PROVIDE RETURN DUCT SMOKE DETECTOR AUTOMATIC SHUT DOWN OF ALL NEW HEATING, COOLING, OR VENTILATION EQUIPMENT MOVING IN EXCESS OF 2000 CFM IN ACCORDANCE WITH SECTION 606 OF THE 2009 IMC. POWER AND INTERLOCK WIRING WITH THE BUILDING FIRE ALARM SYSTEM IS BY THE ELECTRICAL CONTRACTOR. 11. HVAC EQUIPMENT, VALVES AND DAMPERS SHALL BE LOCATED IN EASILY ACCESSIBLE LOCATIONS. UNLESS SHOWN ON ARCHITECTURAL DRAWINGS, REQUIRED ACCESS PANELS SHALL BE PROVIDED AND INSTALLED BY THE GENERAL CONTRACTOR. MINIMUM ACCESS DOOR SIZE FOR VALVES AND DAMPERS TO BE 18" X 18". 12. HEAT TRACING OF PIPING, WHERE INDICATED, SHALL BE PROVIDED AND INSTALLED BY THE HVAC CONTRACTOR. THE HVAC CONTRACTOR IS TO COORDINATE THE HEAT TRACE POWER WIRING WITH ELECTRICAL CONTRACTOR. 13. MOTORS STARTERS NOT LISTED AS BEING PROVIDED IN THE HVAC EQUIPMENT SCHEDULES ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR. 14. WITHIN 90 DAYS AFTER THE DATE OF SYSTEM ACCEPTANCE, RECORD DRAWINGS OF THE ACTUAL INSTALLATION TO BE PROVIDED TO THE BUILDING OWNER. RECORD DRAWINGS SHALL INCLUDE AS A MINIMUM THE LOCATION AND PERFORMANCE DATA ON EACH PIECE OF EQUIPMENT, GENERAL CONFIGURATION OF DUCT AND PIPE DISTRIBUTION SYSTEM, INCLUDING SIZES, AND THE TERMINAL AIR AND WATER DESIGN FLOW RATES. 15. OPERATING AND MAINTENANCE MANUALS TO BE PROVIDED TO THE BUILDING OWNER THAT INCLUDE: SUBMITTAL DATA, NAMES AND ADDRESSES OF AT LEAST ONE SERVICE AGENCY, HVAC CONTROLS SYSTEM MAINTENANCE AND CALIBRATION INFORMATION AND A COMPLETE OPERATIONAL NARRATIVE FOR EACH SYSTEM. 16. COMMISSIONING IS REQUIRED ON THIS PROJECT IN ACCORD WITH WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416 AND WITH LEED NC -2.1 FUNDAMENTAL BUILDING SYSTEMS COMMISSIONING AND ADDITIONAL COMMISSIONING. 17. A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED AND FILED WITH THE OWNER 18. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING MUST OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHOULD BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC). - TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC). - ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHOULD BE CAULKED. FILLING WITH ROCK WOOL OR FIRESAFING ("MONOCOAT") IS NOT ACCEPTABLE (BY GC). - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING) SHOULD BE SEALED WITH FIRE CAULKING ON BOTH SIDES OF THE PENETRATION. - USE SECTION 909.5 OF THE 2009 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA. FOLLOWING THE GUIDELINES FOR SMOKE BARRIER CONSTRUCTION. - ALL DOORS MUST BE PROVIEDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 19. DAMPERS USED FOR OUTDOOR AIR INTAKE, EXHAUST, OR RELIEF SHALL HAVE THE FOLLOWING MAXIMUM LEAKAGE RATES AT 1" W.G. (PER AMCA STANDARD 500): MOTORIZED DAMPERS:10 CFM/S.F. GRAVITY DAMPERS: 20CFM/S.F. (40 CFM/S.F. FOR DAMPERS SMALLER THAN 24" IN EITHER DIMENSION). 20. OUTSIDE AIR INTAKE, EXHAUST, AND RELIEF DAMPERS SERVING CONDITIONED SPACES MUST BE MOTORIZED (FAIL CLOSED) PER WSEC 1412.4.1, EXCEPT AS ALLOWED BY WSEC. APN# 734060-0602 LEGAL DESCRIPTION: RIVERSIDE INTERURBAN TRS LOT 8 OF TUKWILA BLA L02-057 REC #20030327900002 LOCATED IN SE 1/4 OF SEC 9 & SW 1/4 10 IN 23-04 INSTALL (1) NEW PACKAGED ROOF TOP HEAT PUMP AND ASSOCIATED DUCTWORK AND DIFFUSERS. TITLE PROJECT ENGINEER ACCOUNT MANAGER PRODUCTION MANAGER SHEET METAL FOREMAN AIR BALANCE FOREMAN LOW VOLT ELECTRICAL FOREMAN COMMISSIONING FOREMAN FACILITIES DIRECTOR GENL SUPT GENL PROJ MANAGER NAME PAUL YOUNG STEVE FLINK DARYL ANDERSON TIM FELTON STEVE BAKER DAVE GOFF BRIAN WHEELER ART AGADJANYAN SARAH MARQUES COMPANY MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER MACDONALD MILLER PHONE NUMBER 206-768-4230 253-680-3172 206-768-4216 206-407-2692 206-768-3824 206-407-2638 206-571-2659 206-409-7121 206-281-8700 EMAIL PAULYOUNG@MACM ILLER.COM STEVE. FLIN K@MACMI LLER.COM DARYL.ANDERSON@MACM ILLER.COM TI M. FELTON@MACMILLER.COM STEVE.BAKER@MACMILLER.COM DAVE.GOFF@MACMILLER.COM BRIAN.WHEELER@MACMILLER.COM NAME TM0.01 TM0.01 S TM2.04 TM2.05 TITLE NAME TITLE SCHEDULES - HVAC SITE MAP 4TH FLOOR HVAC PLAN PARTIAL ROOF AND ELEVATION PLAN REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NO i_ Revisions will require a new plan submittal and may include additional plan review fees. FILE PY Permit No. t ew approval is i ,; ►to err= art +g pp:! of constructiondocuments does not authorize Ott. v: tion of any adopted ccde or where. Receipt proved Field By Data: q4s113 City Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED APR 11 2013 Ug - 5 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 0 8 2013 PERMIT CENTER E 00 `> E 0 (a EE co D) (1) LL 0 0 2 z V 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 W 0 REVISIONS: 1 1 1 1 1 1 1 r1 TJ 1 L N 0 O 0 0 U w CL. I I I I I I l< Co CO ENGINEER: P YOUNG REVISIONS: z 0 F- U (/) Z 0 0 0 u_ 0 w r� VJ LAST REVISED: 04-02-13 CHECKED BY: DATE PLOTTED: B GEZON 04-02-13 CAD: ISSUE DATE: A HAMILTON 04-02-13 DRAWING NUMBER: D-3404-7336242-00 SHEET NUMBER: TM0.01 1 0. n 0 N 0 0 :\733\6242 Sa Thursday, April 04, 2013 9:06:10 AM (f) LC) te113• to Lf S 1 2 8T ST REVIEWED FOR E COMPLIANCE APPROVED APR 11 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 0 8 2013 PERMIT CENTER ■ co 0 co �(0 0 < 0 ti 0 0 rrsN N 0 ALL 0 c006 0 co 0) 0 0 0 2 z° 1 1 1 1 1 1 1 1 ENGINEER: P YOUNG CHECKED BY: DATE PLOTTED: B GEZON 03-28-13 CAD: ISSUE DATE A HAMILTON 03-28-13 DRAWING NUMBER: D-3404-7336242-00 SHEET NUMBER: r7I I N I 0 0 0 H LiJ I I\ LTJ 0 z 0 UJ 0 REVISIONS: Z 0 U (1) Z 0 U 0 LL. 0 w (i) LAST REVISED: 03-28-13 TMO.O1 S J:\733\6242 Sabey DHS Ops Center RTU SF\00\2 B ( 4 ) AC -2-427 798 CFM ( 5) AC -2-426 782 CFM 0 r=.==•=F==.-==_-=.r-_,jF:=====L--=__d_____ r, Eel ft—EC 12-2411 DT1 2-242 DT8-215 AC -2-425 1244 CFM 7 AC -1-427 570 CFM AC -1-425 470 CFM ( 8 ) AC -1-424 1085 CFM DT1Q -3 1 DT1 0 - 08 DT12 470 it !! hI AC -1-422 1100 CFM AC -1-423 1008 CFM ( 9 ) AC -1-426 480 CFM DT1 0-241 EC -1 h`.--1 (TIP) AREA OF WORK z 10 AC -1-421 530 CFM., '10.2, FvusER;i_ Typ MAT( 350 10 DT1 0-297 18X DT121><1„D 550 11111DT12 V \\I 550 x DT12 480 14x14 40x24 SL TRANSFER RA DUCT DT12: " RLIQ 4hiblEC " RGAS(T1/41:N)U 4" PUMPED CDNS TO ROOF. 18X18X24SL MIXI BOX BY 180EL 16�EL 18x18 I 494 200 D DA v1 X-14X36SL R H BALANCIN MPER , DT8-127 itifiii1151115515111iiiiiiiktatiati 1 601 TA DUdf DT14-625 EC5 /SLM LBOW DT8 -155 DT14-625 26X22 .IUP TO EF -25 OR E-1200 UP TO EF -8 ON E-4250 DT10-252 18X18 EC5 W/SLM ELBOW DT10-252 AC -1-428 1200 CFM AC -1-420 900 CFM AC -1-429 1000 CFM 24X28 DT1 4-625 X 8? Z EC 1 THRU ROOF !ffilsida.), diegligo13137,0 DT10-252 DT10-252 II.. 1! Itc, • 11 -- 1_1 1.1 11. 11 • DT1 11 -420 CFM - 11 RETURN AIR DT8- 204 31X18? 31 6-10/ DT10 -300 „CFM- (TYP3) 12X12 1 12X12 50X26 DT 0 185 DT10 - 185 -183 18X18 DT8-120 Ag0X26 2 TYP. DT10-317 60X30 OPENING ABV C ILING F RETUR AIR DT10-317 EC W/S DT1 0-330 16X14 DT12 -362 DT12-362 EC4 W/SLM. ELBOW DT10-167 EC5 W/SL EC5 W/S M EC1 DT6-106 EC1 DTI 0-245 DT10 -311 180EL 180EL DT1 0-167 DT10-280 W/SLM ELBOW DT12-370 , DT8 2-388 DT1 0-2;0 D8-125 DT8-183 DT1O-105 DT12-364 DT12- 64 DT1 2-38 DT1 2-383 DT12 -396 DT1 2-396 12-521 111 0 0 I1T4261111 VAIN MIMIIIIII11111 raMillifill mommomnalumommi -1111111111111111SIMMEMOI 111111111111M11111101011111111 MIN1111111110111111111111111111111111 , .1 onimmiumumummisM DT1 2-3 DT12 - DT12-313 DT12-29 AC -2-406 1164 CFM 2013 9:05:59 AC -2-405 1042 CFM AC -2-407 821 CFM 1440 CFM DT12-38 665 CFM 724 CFM DT12-383 -1-412 AC -1-413 1374 CFM 634 CFM AC -1-414 764 CFM AC -1-415 1520 CFM AC -1-418 913 CFM AC -1-416 521 CFM AC -1-417 739 CFM L)\ I \ p 4C-1--419 675 CFM ( B SHEET NOTES 1. MOTORIZED DAMPER REQUIRED ON OSA INTAKE BEFORE MIXING BOX. DAMPER TO BE LINE VOLTAGE AND INTERLOCKED WITH IU -401. DAMPER TO CLOSE WHEN SYSTEM IS IN UNOCCUPIED MODE. 2009 -WSEC 1412.4.1 (12 REVIEWED FOR CODE COMPLIANCE APPROVED APR 1 1 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 0 8 2013 PERMIT CENTER z 1 /8" = C15 co co o cD cs.) <(0 cD ' o a 04 co u_ (/) o a a) a) > < o o CNJ a aic o N. r- w.macmiller.com WA Lic No: MACDOFS980RU 11111111 11111111 N) c•Nr 0 •4- 0 I I I I I I l< 0 zz2 „u-10 LdI9 L.L. 01_6 cozt. iw§ a2L-1 Wig _1<C caO_- <uJ u) co co ENGINEER: P YOUNG CHECKED BY: B GEZON CAD: A HAMILTON w 0 REVISIONS: REVISIONS: z 0 (/) z0 0 LL0 (/) (1) LAST REVISED: 04-02-13 DATE PLO1TED: 04-02-13 ISSUE DATE: 04-02-13 DRAWING NUMBER: D-3404-7336242-00 SHEET NUMBER: TM2.04 10 0 N r-- M en t to.c J:\733\6242 Sabey DHS Ops Center RTU SF\00\2 co 0 0 0 0 0. 0 B} D (E 3" PUMPED CONS TO ROOF;DRAIN. REFRIGERANT LINES DOWN THROUGH SLAB. PUMPEDCDNS UP THROUGH SLAB. COVER PENETRATION WITH SM CAP. 1 X-RAY SLAB :0R CORE DRILL LOCATIONS. CONSULT STRUCTURAL ENGINEER FOR MINIMUM ALLOWABLE CLEARANCE TO TENDONS. MOUNT UNIT ON ROOFED IN SLEEPERS BY OTHERS. MAINTAIN 12" CLEAR ON TWO SIDES. OSA INTAKE W/ GOOSE NECK COVER FACING WEST. 60W DUCT DOWN THROUGH SLAB. 3" R-7 WRAP. 0 I GRADE -\1/4. 19'-0" OU -501 \ \ PARAPET ROOFED IN SLEEPER N TOP OF ROOF SLAB /1PARTIAL EAST ELEVATION VIEW 2.05 1/8" = 1'-0" REVIEWED FOR ;OCE COMPLIANCE APPROVED APR 11 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 0 8 2013 PERMIT :CENTER Co co o r— co( D 0) 0 0 0 Lu I I 1C T 1- w 0 REVISIONS: z 1/8" = 1'-0 ENGINEER: P YOUNG CHECKED BY: B GEZON CAD: A HAMILTON z 0 U z 0 U 0 LL 0 w (/) ) LAST REVISED: 04-02-13 DATE PLOTTED: 04-02-13 ISSUE DATE: 04-02-13 DRAWING NUMBER: D-3404-7336242-00 SHEET NUMBER: TM2.05