Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-066 - ANDOVER BUILDING - ALTERATION
ANDOVER BUILDING 130 ANDOVER PK E M13-066 City oilkukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 0223100040 Address: 130 ANDOVER PK E TUKW Project Name: ANDOVER BUILDING Permit Number: M13-066 Issue Date: 04/22/2013 Permit Expires On: 10/19/2013 Owner: Name: PARK EAST REAL ESTATE LLC Address: C/O IRONWOOD INVESTMENTS LLC , 1501 N 200TH ST 98133 Contact Person: Name: KIRSTEN FAUSKO Address: 1221 SECONDAV N , KENT WA 98032 Email: KFAUSKO@HERMANSON.COM Contractor: Name: HERMANSON COMPANY LLP Address: 1221 2ND AV N , KENT, WA 98032 Contractor License No: HERMACL005BJ Phone: 253-796-5892 Phone: 206-575-9700 Expiration Date: 08/25/2014 DESCRIPTION OF WORK: REPLACE AIR VALVES ON ALL EXISTING VAVS. REPLACE WATER VALVES ON ALL EXISTING HW RADIATORS LOCATED ALONG THE PERIMI TER OF THE BUILDING (84 TOTAL) Value of Mechanical: $49,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $783.81 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Date: lib") -11 �J Print Name: V-errS51-eM jtJ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. IA ) ACC O.inee.d• AA o0 WW1 • IP PERMIT CONDITIONS Permit No. M13-066 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-066 Printed: 04-22-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: o4i12113 toIIZU"5 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION Site Address: 1 O'V'A �a r16 $"1 Tenant Name: kat VVir QL(.f Gtrl {ala' PROPERTY OWNER `' Name: farts_ &&fl Re ( lr$'j W L - Address: i so i cel ?40a s fr-ec - City: skote_ti (/1!� State: mar Zip: q$133 CONTACT PERSON – person receiving all project communication Name: V", r1fyi._ fordikao Address: 11.21 2,_ r/ AV= /, City: vent_ State: vvitv Zip:61903.) Phone:1s.� -1 R , S-$ er 2. Fax: Email: t/ fes„ 1,. _ e (_ _-tYN.A,VISD yi . CoVi-t King Co Assessor's Tax No.: V 3 I ©OD H 0 Suite Number: Floor: New Tenant: ❑ Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: I f r v- uavt..S b 'i 1 , . _fAye , Address: 1244 ��G�` City: `, ^ r State: ,t A, _ Zip: ca 31 Phone:�k S7 _41looFax: 74b.---siS - q1po0 Contr Reg No.: tiewikuoos 65 Exp Date:0 /-/) K Tukwila Business License No.: 09_ ii 5 ci Valuation of project (contractor's bid price): $ ' 61 000 Describe the scope of work in detail: Rep titre air- V`atIVes o'K all e2c(s*v V4V`s PAO, L L. \ra t V es a ad/ -e K l S-1 l fi tW-tby of Corte I e cot -40( h /r � f - «E . 6u,11 41�v ( . Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement l Fuel Type: Electric ❑ Gas ❑ Other: H:\Applications\Forms-Applications On Line \2011 Applications\ Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 s Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator – domestic Incinerator – comm/industrial • Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction – in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review – applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNE Signature: AUTHORIZED AGENT: Print Name: rs+ey Mailing Address: 1 2-1. Vl4. %V' Date: Day Telephone: 2S ,-11( S$ c't wf9. '5t-632 City H:\Applications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9.11.docx Revised: August 2011 bh State Zip Page 2 of 2 • • SET RECEIPT RECEIPT NO: R13-01308 Initials: JEM User ID: 1165 Payee: KRISTEN FAUSKO, HERMANSON COMPANY LLP Payment Date: 04/12/2013 Total Payment: 1,203.11 SET ID: 0412 SET NAME: HERMANSON SET TRANSACTIONS: Set Member Amount EL13-I 419.30 783.81 TOTAL: 41-9-36—' TRANSACTION LIST: Type Method Description Amount Payment Credit C VISA ACCOUNT ITEM LIST: Description TOTAL: 1,203.11 1,203.11 Account Code Current Pmts ELECTRICAL PERMIT - NONR MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.101.00.0 000.322.102.00.0 000.345.830 TOTAL: 419.30 627.05 156.76 1,203.11 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188. (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: /Type !+ 1 ti CJ U�Y'P f r of Inspection:,/� 11' rT (..._ Add ss: _ A t t (.) > Ne/ P1L Date Called: Special Instructions: Date Wanted: ' %-(77— ) a.m. prii. Requester: Phone No: 'Approved per applicable codes. Corrections required prior to approval. COMMENTS: specter: �f Old" - 17) \ at El SPECTION FEE REQURED. Prior to next inspection.fee must be p\ay at 6300 Southcenter Blvd.. Suite 100.. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit ' •3- off, c PERMIT NO. CITY OF TUKWILA BUILDING. DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Ak1;+ a (zip IC - Type of Inspection: TkcIt(ot-i —sN.J Address: I3()• A 2 PSC_ Date Called: Special Instructions: • Date Wanted: !O — qi - (2 Requester: Phone No: (d(-755-23 7? "% Ap_proved per applicable codes. Corrections required prior to approval. COMMENTS: Date: 1 b EINSPECTION FEE R .QUIRED. Fj`rior to next inspection, fee must be aid at 6300 Southcente Blvd., Suite 100. Call to schedule reinspection. March 12, 2014 Jennifer Nelson Hermanson Company 1221 Second Ave N Kent, WA 98032 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Request for Extensions Permit Numbers M13-066, M13-089, & M13-108 Dear Ms. Nelson, This letter is in response to your written request for an extension to permits M13-066, M13-089, and M13-108. The Building Official has reviewed your letter and considered your request to extend the above referenced permits. It has been determined that the City of Tukwila Building Division will be granting an extension to the permits through October 6, 2014 provided at least one inspection is approved on each of the permits prior to expiration of the extension. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, File: Permit No. M13-066, M13-089, & M13-108 W:\Permit Cente,\Extension Letters\Permits\201AM13-066 Permit Extension.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Bill Rambo From: Jennifer Nelson <jen.nelson@hermanson.com> Sent: Thursday, March 06, 2014 2:11 PM To: Bill Rambo Subject: Permit Extension Request Mr. Rambo, We would like to request an extension on the following permits: M13-066 M 13-089 M 13-108 114 c e iv>po4 We will be ready to call for final within the next 2 weeks. Thanks, Jennifer Nelson Project Manager Hermanson direct 253-796-5834 !main 206-575-9700 1 fax 206-575-9800 1221 2nd Ave North, Kent, Washington 98032 www.hermanson.com Please consider the environment before printing this e-mail Jennifer Nelson Project Manager Hermanson direct 253-796-5834 1 main 206-575-9700 1 fax 206-575-9800 1221 2nd Ave North, Kent, Washington 98032 www.hermanson.com Please consider the environment before printing this e-mail 1 4 o - 4-/e/Amct , K 14o er Gid 4/ 91210/P ,'g pyo-ssed pF; aN 4- ...)0 (--iD/u 0 la Lfhle_ AbCiEWED MY OF TUKVIIRA MAR 06. 2014 PERMIT CENTER tA-ca 'h) lip I DOLI 3/3/2014 City of Tukwila Department of Community Development KIRSTEN FAUSKO 1221 SECONDAV N KENT, WA 98032 RE: Permit No. M13-066 ANDOVER BUILDING 130 ANDOVER PK E Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director New Inspection Request Line 206 438- 9350 In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 4/7/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 4/7/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall Technician File No: M 13-066 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 09-03-2013 KIRSTEN FAUSKO 1221 SECONDAV N KENT WA 98032 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Permit No. M13-066 ANDOVER BUILDING 130 ANDOVER PK E TUKW Dear Permit Holder: In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 10/19/2013. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or fmal inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven (7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 10/19/2013, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, Bill Rambo Permit Technician File: Permit File No. M13-066 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 •PERMiT COORD COSIC PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-066 PROJECT NAME: ANDOVER BUILDING DATE: 04/12/13 SITE ADDRESS: 130 ANDOVER PK E X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision #• after Permit Issued DEPARTMENTS: �uilding Division Public Works • ❑ A A)//f Fire Prevention Structural • Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 04/16/13 Complete 1M Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: Departments determined incomplete: Bldg 0 LETTER OF COMPLETENESS MAILED: Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route AX1 REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/14/13 Approved ❑ Approved with Conditions Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Contractors or Tradespeople Prr ter Friendly Page r General/Specialty Contractor A business registered as a construction contractor with Lal to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HERMANSON COMPANY LLP UBI No. 602004844 Phone 2065759700 Status Active Address 1221 2Nd Ave N License No. HERMACLOO5BJ Suite/Apt. License Type Construction Contractor City Kent Effective Date 1/11/2000 State WA Expiration Date 8/25/2014 Zip 980322945 Suspend Date County King Specialty 1 General Business Type Limited Liability Partnership Specialty 2 Unused Parent Company License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HERMAC'016RN HERMANSON CORPORATION Construction Contractor General Unused 1/11/2000 8/21 /2002 Archived HERMAC'217NT HERMANSON CORPORATION Construction Contractor Air Heat,Ventilation,Evaporat Metal Fabrication 8/30/1979 8/21/2000 Archived Business Owner Information Name Role Effective Date Expiration Date NICOLAISEN, KNUT H Partner/Member 08/05/2010 Amount BROCK, DANIEL L Partner/Member 08/05/2010 GL0370326109 FOX, DEAN M Partner/Member 08/05/2010 HENGEL, STEPHEN A Partner/Member 08/05/2010 American Zurich Insurance Comp DYCKMAN, KENNETH A Partner/Member 08/05/2010 ROBINETT, PAUL J Partner/Member 08/05/2010 9 HERMANSON, RICHARD L Partner/Member 01/01/1980 08/21/2011 ALMON, KEVIN Partner/Member 01/01/1980 08/05/2010 MACDONALD, JAMES Partner/Member 01/01/1980 08/05/2010 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 WESTERN SURETY CO 929381801 01/01/2006 Until Cancelled $12,000.00 12/01/2005 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 11 American Zurich Insurance Comp GL0370326109 08/21/2012 08/21/2013 $1,000,000.00 08/14/2012 10 American Zurich Insurance Comp GL0370326108 08/21/2011 08/21/2012 $1,000,000.00 08/18/2011 9 American Zurich Ins Co GL0370326107 08/21/2010 08/21/2011 $1,000,000.00 08/18/2010 8 ZURICH AMERICAN INS CO GL0370326106 08/21/2008 08/21/2010 $1,000,000.00 08/24/2009 7 08/21/2004 08/21/2008 $1,000,000.00 08/20/2007 httnc•//fnrtress_wa_ gnv/lni/bbin/Print.asnx 04/22/2013 b 10o '.!) A AC ACH ACT AD ADD'L AFF AFG AHU ALUM AMP/AMPS AP ARCH BC BDD BF BHP BLDG BOD BOP BOT BS BTU BTU H CAP CC CD CDWR CDWS CFM CHWR CHWS CLG COL CONC COND CONN CONT CONTR COORD COP CT CU cw DB D BA DDC DEFL DEG DG DIA DMPR DN DT DWG EXH EA EAT EC EER EF EFF EL ELEC/ELECT EP EMCS ENT EQUIP ESP EWT EXIST F FAC FD FDC FF FIC FIO FLA FLEX FLR FOB FOIC FOS FOT FP FPM FSD FT FUT FV G GA GALV GC GEN GPM GR GRD GWB HD HORIZ HP HR HSPF HT HWTG HWR HWS HX MECHANICAL ABBREVIATIONS AMPS AIR CONDITIONING AIR CHANGES PER HOUR ACOUSTICAL TILE CEILING ACCESS DOOR ADDITIONAL ABOVE FINISHED FLOOR ABOVE FINISHED GRADE AIR HANDLING UNIT ALUMINUM AMPERAGE ACCESS PANEL ARCHITECT BEADED COLLAR BACKDRAFT DAMPER BELOW FLOOR BRAKE HORSEPOWER BUILDING BOTTOM OF DUCT BOTTOM OF PIPE BOTTOM BIRD SCREEN BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CONTROLS CONTRACTOR CEILING DIFFUSER/CONDENSATE DRAIN CONDENSER WATER RETURN CONDENSER WATER SUPPLY CUBIC FEET PER MINUTE CHILLED WATER RETURN CHILLED WATER SUPPLY CEILING COLUMN CONCRETE CONDENSATE CONNECT/CONNECTED/CONNECTION CONTINUOUS/CONTINUATION CONTRACTOR COORDINATE COEFFICIENT OF PERFORMANCE COOLING TOWER CUBIC/CONDENSER UNIT DOMESTIC COLD WATER/CONDENSER WATER DUCTBOARD/DRY BULB DECIBEL DIRECT DIGITAL CONTROL DEFLECTION DEGREE/ DEGREES MODULAR DIFFUSER (GWB CEILING) DIAMETER DAMPER DOWN MODULAR DIFFUSER ("T -BAR" CEILING) DRAWING EXHAUST EACH ENTERING AIR TEMPERATURE EGGCRATE GRILLE/END CAP/ELEC CONTRACTOR ENERGY EFFICIENT RATING EXHAUST FAN EFFICIENCY ELEVATION ELECTRICAL/ELECTRIC END PLUG ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUIPMENT EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXISTING FAHRENHEIT FIRE ALARM CONTRACTOR FIRE DAMPER FIRE DEPARTMENT CONNECTION FINISHED FLOOR FURNISHED AND INSTALLED BY CONTRACTOR FURNISHED AND INSTALLED BY OWNER FULL LOAD AMPS FLEXIBLE FLOOR FLAT ON BOTTOM FURNISHED BY OTHERS. INSTALLED BY CONTRACTOR FLAT ON SIDE FLAT ON TOP FIRE PROTECTION FEET PER MINUTE FIRE/SMOKE DAMPER FOOT/FEET FUTURE FACE VELOCITY GRILLE GAUGE/GALLON GALVANIZED GENERAL CONTRACTOR GENERAL GALLONS PER MINUTE GRILLE GRILLE/REGISTER/DIFFUSER GYPSUM WALL BOARD HEAD HORIZONTAL HORSEPOWER HOUR HEATING SEASONAL PERFORMANCE FACTOR HEIGHT HIGH WALL TRANSFER GRILLE HOT WATER RETURN HOT WATER SUPPLY HEAT EXCHANGER HZ BC CW D E MC N . N WG PLV KW HERTZ NTERNATIONAL BUILDING CODE NDUSTRIAL COLD WATER NSIDE DIAMETER/DIMENSION NVERT ELEVATION NTERNATIONAL MECHANICAL CODE NCHES NCHES WATER GAUGE NTEGRATED PART LOAD VALUE KILOWATTS LAT LEAVING AIR TEMPERATURE LB/LBS POUND/POUNDS LD/LIN DIFF LINEAR DIFFUSER LF/LIN FT LINEAL FOOT/FEET LPG LIQUID PROPANE GAS LVG LEAVING LWA SOUND POWER LWG LOW WALL GRILLE LWR LOW WALL REGISTER LWT LEAVING WATER TEMPERATURE MAX MAXIMUM MAU MAKE UP AIR UNIT MBH 1000 BRITISH THERMAL UNITS MCA MINIMUM CIRCUIT AMPACITY MD MOTORIZED DAMPER MFR MANUFACTURER MISC MISCELLANEOUS MIN MINIMUM/MINUTE MT MOUNT MTD MOUNTED MUW MAKE-UP WATER N/A NOT APPLICABLE NC NORMALLY CLOSED/NOISE CRITERIA NG/NGAS NATURAL GAS NIC NO NPW N -R OA/OSA OB OBD OD P PCF PD PH POC PRESS PSI PSIG QTY R RA RD/RND REF REG REQ RESID RF RG RL RPM RS S SA SAT SD S/D SEER SENS SG SL SM SPEC SO SOG SP SQ FT SR SS STRUC T TA TEMP TBD TG TOC TOD TOS TOT TSP TSTAT TYP UH UNO V VIAQC VD VEL VERT VFD VOL W WB WG W/ W/O W/SF WSEC NOT IN CONTRACT NORMALLY OPEN/NUMBER NON -POTABLE WATER NON-RESIDENTIAL OUTSIDE AIR OPPOSED BLADE OPPOSED BLADE DAMPER OUTSIDE DIAMETER/DIMENSION PUMP POUNDS PER CUBIC FOOT PRESSURE DROP, PHASE POINT OF CONNECTION PRESSURE POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAUGE QUANITY RETURN GRILLE/RELOCATED/RETURN RETURN AIR ROUND REFERENCE REGISTER REQUIRED RESIDENTIAL RELIEF RETURN GRILLE REFRIGERANT LIQUID REVOLUTIONS PER MINUTE REFRIGERANT SUCTION SUPPLY SUPPLY AIR SATURATION SMOKE DETECTOR SLIP & DRIVE CONNECTION SEASONAL ENERGY EFFICIENCY RATING SENSIBLE SUPPLY GRILLE SOUND LINED SPIRALMATE/SHEETMETAL SPECIFICATION SCREENED OPENING SLAB ON GRADE STATIC PRESSURE SQUARE FEET SIDE WALL REGISTER STAINLESS STEEL STRUCTURAL TRANSFER TRANSFER AIR TEMPERATURE/TEMPORARY TO BE DETERMINED TRANSFER GRILLE TOP OF CONCRETE/CURB TOP OF DUCT TOP OF STEEL/TOP OF SLAB TOTAL TOTAL STATIC PRESSURE THERMOSTAT TYPICAL UNIT HEATER UNLESS NOTED OTHERWISE VOLT VENT. AND INDOOR AIR QUALITY CODE VOLUME DAMPER VELOCITY VERTICAL VARIABLE FREQUENCY DRIVE VOLUME WALL/WALLS, WRAPPED DUCT WET BULB WATER GAUGE WITH WITHOUT WATTS PER SQUARE FOOT WASHINGTON STATE ENERGY CODE MECHANICAL LEGEND 10X10 10X�1®I I10X10;;; : 1 0 X 1 0 \. 10X10Li t 10X10 10X10 1/ 10X10 b 10co (�I 100 X17► ¢1o0 100 T.: 1001 R (S) e0 CD1-100 8�O 0 RECTANGULAR SUPPLY AIR DUCT - TURNING UP OR TOWARD RECTANGULAR SUPPLY AIR DUCT - TURNING DOWN OR AWAY RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING UP OR TOWARD RECTANGULAR EXHAUST OR RETURN AIR DUCT - TURNING DOWN OR AWAY ROUND DUCT - TURNING UP OR TOWARD ROUND DUCT - TURNING DOWN OR AWAY FLATOVAL DUCT TURNING UP OR TOWARD FLATOVAL DUCT - TURNING DOWN OR AWAY DUCT OVERLAP BOOT TAP 45° TAP VOLUME DAMPER CHANGE OF ELEVATION RISE(R) DROP(D) TRANSITION TURNING VANES/SPLITTERS DUCT MOUNTED SMOKE DETECTOR BACK DRAFT DAMPER FLEXIBLE DUCT AIR FLOW DIRECTION FORCED AIR) AIR FLOW DIRECTION DRAWN AIR) MOTOR OPERATED DAMPER FLEX CONNECTION SMOKE DAMPER FIRE DAMPER COMBINATION FIRE & SMOKE DAMPER SOUND TRAP ACCESS DOORS ACOUSTICALLY LINED DUCT (SOUND LINED) DUCT BOARD FABRIC DUCT VAV BOX CEILING SUPPLY AIR DIFFUSER (SHOWN WITH REDIRECTED AIR CORE) CEILING RETURN, TRANSFER OR EXHAUST AIR GRILLE SLOTTED DIFFUSER (PLAN VIEW) REVISION CLOUD & TRIANGLE ROUND DUCT SYMBOL FLATOVAL DUCT SYMBOL DEGREES SYMBOL POINT OF CONNECTION GRD TAG IDENTIFIER = TYPE -CFM SIZE THERMOSTAT/TEMPERATURE SENSOR HUMIDITY SENSOR SMOKE DETECTOR STATIC PRESSURE SENSOR EXISTING DUCTWORK DEMO DUCTWORK WALL -MOUNTED GRILLE • PIPE ELBOW UP • PIPE ELBOW DN z z ®® z da J z- CHWS -5 CHWR --5 RL RS z- NG - z-- LPG --S z-- CDWS s CDWR --s HWS HWR -5 t-- COND -s DIRECTION OF FLOW DIRECTION OF SLOPE DOWN PLUG OR CAP GAS PRESSURE REDUCING ASSEMBLY SOLENOID VALVE PUMP CHILLED WATER SUPPLY CHILLED WATER RETURN REFRIGERANT LIQUID REFRIGERANT SUCTION NATURAL GAS LIQUID PROPANE GAS CONDENSER WATER SUPPLY CONDENSER WATER RETURN HEATING WATER SUPPLY HEATING WATER RETURN CONDENSATE MECHANICAL GENERAL NOTES 1. ALL WORK SHALL CONFORM TO ALL APPLICABLE CODES AND REGULATIONS, INCLUDING, BUT NOT LIMITED TO THE 2006 IBC, 2006 WSEC & 2006 WSMC. 2. DIMENSIONS ARE TO FACE OF STUD, CONCRETE, OR MASONRY UNLESS NOTED OTHERWISE. 3. DO NOT SCALE DRAWINGS. DIMENSIONS GOVERN. 4. VERIFY ALL EXISTING CONDITIONS, DIMENSIONS, DETAILS, ETC. NOTIFY ENGINEER OF ANY DISCREPANCIES PRIOR TO PROCEEDING WITH THE WORK. 5. WHEN CONSTRUCTION DETAILS ARE NOT SHOWN OR NOTED FOR ANY PART OF THE WORK, DETAILS SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. IF ADDITIONAL QUESTIONS REMAIN, CONTACT THE ENGINEER PRIOR TO PROCEEDING. 6. ALL STRUCTURAL OPENINGS AND PLATFORMS SHALL BE PROVIDED BY THE GENERAL CONTRACTOR UNLESS NOTED OTHERWI 7. DUCT SEALING AND CONSTRUCTION TO MEET SMACNA AND ENERGY CODE REQUIREMENTS. UNLESS OTHERWISE NOTED, LOW PRESSURE DUCTWORK (DOWNSTREAM OF VAV BOXES, CONSTANT VOLUME AC SYSTEMS, TOILET EXHAUSTS, ETC.) TO MEET 2" CONSTRUCTION STANDARDS WITH SEAL CLASS C. MEDIUM PRESSURE DUCTWORK (UPSTREAM OF VAV BOXES, HIGH VELOCITY EXHAUSTS, ETC.) TO MEET 4" CONSTRUCTION STANDARDS WITH SEAL CLASS A. DUCT RISERS IN SHAFTS WITH DAMPERED PENETRATIONS TO MEET 6" CONSTRUCTION STANDARDS WITH SEAL CLASS A. 8. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS NOTED OTHERWISE. 9. ALL DUCT DIMENSIONS ARE CLEAR INSIDE DIMENSIONS AFTER LINING HAS BEEN INSTALLED. DRAWING INDEX SHEET NO. SHEET TITLE CURRENT REVISION RESID. INSULATION R -VALUE REMARKS M0.00 LEGEND, ABBREVIATIONS, GENERAL NOTES, & SHEET INDEX - HVAC R-7 M2.01 1ST FLOOR PLAN - HVAC OUTSIDE AIR INTAKE M2.02 2ND FLOOR PLAN - HVAC R-8 M2.03 3RD FLOOR PLAN - HVAC NOT WITHIN CONDITIONED SPACE: IN CONCRETE, IN GROUND R-5.3 R-5.0 1,2 SUPPLY WITH <55' OR >105° AIR TEMPERATURE WITHIN CONDITIONED SPACE R-3.3 NOT REQ. 1,2 1.5 1.5 1.5 HWS&R 105-140 0.24-0.28 .100 0.5 1.0 1.0 ErA err.: PEa iMjT LEQUIFCID FOR: 0 Mechanical 1210EIectrical LePlumbing as Pipkn City of Tukwila [ BUILDING 10. OUTSIDE AIR INTAKES ON ALL' AIR HANDLING UNITS SHALL BE 10 FEET AWAY FROM ANY FUEL BURNING EQUIPMENT, AND 10 FEET AWAY FROM, OR 3 FEET BELOW ANY PLUMBING VENT OR EXHAUST OUTLET. 11. ALL AIR ECONIMIZERS SHALL BE CAPABLE OF THE FOLLOWING: -0% TO 100% OF THE DESIGN SUPPLY AIR -CONTROLLED BY A CONTROL SYSTEM DETERMINING IF THE OUTSIDE AIR CAN MEET PART OR ALL OF THE BUILDING COOLING LOADS. -INTEGRATED TO PROVIDE PARTIAL COOLING EVEN WHEN MECHANICAL COOLING IS REQUIRED. 12. OUTSIDE AIR INTAKE, RELIEF, AND EXHAUST OPENINGS SHALL BE EQUIPPED WITH MOTORIZED OR GRAVITY DAMPERS WHICH CLOSE AUTOMATICALLY WHEN SYSTEM IS OFF OR UPON POWER FAILURE, AS REQUIRED BY ENERGY CODE. 13. THE CONTROL SYSTEM SHALL BE 7 -DAY PROGRAMABLE, CAPABLE OF BEING SET FOR SEVEN (7) DIFFERENT DAY TYPES PER WEEK AND CAPABLE OF A DEADBAND SETTING OF AT LEAST 5 DEGREES F(1OT FOR RESIDENTIABETWEEN THE HEATING AND COOLING SETPOINTS. AHU CONTROL SYSTEM SHALL INCLUDE A MICROPROCESSOR AND BE CAPABLE OFRESETTING SUPPLY AIR TEMPERATURES BY REPRESENTATIVE BUILDING LOADS. 14. RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER THE WASHINGTON STATE ENERGY CODE. AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER. ALL HVAC SYSTEMS SHALL BE BALANCED AND A WRITTEN BALANCING REPORT SHALL BE PROVIDED TO THE OWNER. HVAC CONTROL SYSTEMS SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH SPECIFICATIONS AND APPROVED PLANS. A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY. A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PROVIDED TO THE OWNER. COMMISSIONING, SYSTEM BALANCING, RECORD DRAWINGS AS REQUIRED PER THE WASHINGTON STATE ENERGY CODE. 15. MECHANICAL SYSTEMS SHALL COMPLY WITH SEISMIC RESTRAINT REQUIREMENTS OF THE BUILDING CODE, SMACNA AND ASCE 7. ALL LIFE SAFETY HAZARDOUS MATERIAL RELATED SYSTEMS SHALL BE DEEMED AN Ip=1.5 FOR RESTRAINT METHODS OR AS NOTED ON THE DRAWINGS. REFER TO THE ABOVE NOTED CODES FOR INSTALLATION REQUIREMENTS AND EXCEPTIONS BASED ON SIZING, WEIGHTS AND MOUNTING HEIGHTS. 16. PROVIDE EARTHQUAKE RESTRAINTS FOR HVAC EQUIPMENT AS REQUIRED BY SMACNA SEISMIC RESTRAINT MANUAL, SEIZMIC HAZARD B. WIRES FOR CEILING SYSTEM ETC. SHALL NOT BE HUNG OFF HVAC EQUIPMENT OR HVAC EQUIPMENT SUPPORTS. 17. PROVIDE FIRE AND COMBINATION FIRE/SMOKE DAMPERS WHERE SHOWN ON PLANS AND WHERE REQUIRED PER CODE. 18. ALL PIPING PENETRATIONS THROUGH RATED ASSEMBLIES SHALL BE SEALED WITH AN UL APPROVED FIRE CAULKING. 19. SMOKE DETECTORS PROVIDING AUTOMATIC SHUTDOWN SHALL BE PROVIDED FOR HVAC EQUIPMENT DELIVERING IN EXCESS OF 2000 CFM [INCLUDING MULTIPLE UNITS DUCTED INTO COMMON DISTRIBUTION OR RETURN, WITH AN AGGREGATE SUPPLY GREATER THAN 2000 CFM1 OR EACH STORY OF RETURN SYSTEMS OVER 15,000 CFM IN A MULTI -STORY INSTALLATION, PER CODE. SMOKE DETECTORS SHALL BE FURNISHED AND NSTALLED BY ELECTRICAL CONTRACTOR UNLESS NOTED OTHERWISE. POWER -WIRING AND INTERLOCK TO FIRE ALARM SYSTEM BY ELECTRICAL CONTRACTOR AS APPLICABLE. 20. ACCESS PANELS SHALL BE PROVIDED BY MECHANICAL CONTRACTOR AND INSTALLED BY GENERAL CONTRACTOR. 21. ALL MOTOR STARTERS NOT SHOWN IN EQUIPMENT SCHEDULES SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR. 22. FOR ALL "SEALED AIR TIGHT" SHAFTS OR ROOMS, THE FOLLOWING SHALL OCCUR: - ALL VERTICAL JOINTS INSIDE THE SHAFT SHALL BE PROVIDED WITH A CONTINUOUS SEAL FOR THE LENGTH OF THE JOINT, INCLUDING THE SHAFT CORNERS (BY GC) -TOP AND BOTTOM WALL TRACKS SHOULD BE CAULKED ALONG THEIR ENTIRE LENGTH (BY GC) -ANY FLOOR DECKING PERPENDICULAR TO THE SHAFT SHALL BE CAULKED (BY GC). FILLING WITH ROCK WOOL IS NOT ACCEPTABLE - ANY PENETRATIONS OF THE SHAFT CONSTRUCTION (DUCTWORK, CONDUIT, PIPING, ...) SHALL BE SEALED ON BOTH SIDES OF THE PENETRATION. - USE SECTION 905 OF THE 2006 IBC FOR MAXIMUM ALLOWABLE LEAKAGE AREA, FOLLOWING THE GUIDELINES FOR TIGHT STAIR SHAFT CONSTRUCTION. - ALL DOORS SHALL BE PROVIDED WITH TIGHT FITTING GASKETS, AND OPEN AGAINST THE DIRECTION OF ROOM/SHAFT PRESSURE. 23. MAXIMUM LENGTH OF FLEXIBLE DUCT SHALL BE 12 FEET. REFER TO INSTALLATION DETAILS FOR SUPPORT REQUIREMENTS. FLEXIBLE DUCT FLAME SPREAD RATING SHALL BE < 25 AND SMOKE DEVELOPED RATING SHALL BE < 50. USE FLEXIDUCT MODEL G -KM FOR LOW AND MEDIUM PRESSURE APPLICATIONS OR APPROVED EQUAL. INSULATE DUCT PER NOTE 11 ABOVE. 24. LOCATION AND DETAILS OF EQUIPMENT, DUCT ROUTING, AND CONNECTIONS ARE APPROXIMATE. COORDINATE FINAL LOCATIONS WITH OTHER TRADES. INSTALL IN ACCORDANCE WITH APPROVED SUBMITTALS AND DETAIL DRAWINGS WHEN APPLICABLE. 25. FOR RESIDENTIAL INSULATION ON DUCTWORK AND PIPING SEE ENERGY CODE CHAPTER 5 AND TABLES 5-11 AND 5-12. DUCT INSULATION (R -VALUE) LAST UPDATED: 01/17/07 DUCT TYPE DUCT LOCATION N -R INSULATION R -VALUE RESID. INSULATION R -VALUE REMARKS SUPPLY, RETURN NOT WITHIN CONDITIONED SPACE: ON EXTERIOR OF BUILDING, ON ROOF, IN ATTIC, IN ENCLOSED CEILING SPACE, IN WALLS, IN GARAGE, IN CRAWL SPACES R-7 R-8 1,2,3 OUTSIDE AIR INTAKE WITHIN CONDITIONED SPACE VARIES R-8 1,2,4,5 SUPPLY, RETURN, OUTSIDE AIR INTAKE NOT WITHIN CONDITIONED SPACE: IN CONCRETE, IN GROUND R-5.3 R-5.0 1,2 SUPPLY WITH <55' OR >105° AIR TEMPERATURE WITHIN CONDITIONED SPACE R-3.3 NOT REQ. 1,2 1. REFER TO ENERGY CODE SECTION 1414.2 FOR FURTHER REQUIREMENTS 2. REQUIREMENTS APPLY TO HEATED AND MECHANICALLY COOLED DUCT SYSTEMS AS NOTED. INSULATED COOLED DUCTS REQUIRED A VAPOR RETARDER (PERM < 0.5) AND SEALED JOINTS. 3. WEATHERPROOF BARRIER REQUIRED AROUND DUCTWORK TO MAINTAIN WATER TIGHTNESS. 4. INSULATE OUTSIDE AIR DUCTS TO BUILDING ENVELOPE LEVEL PER ENERGY CODE CHAPTER 13 UNTIL CONNECTED TO EQUIPMENT SERVED OR TO THE CODE REQUIRED SHUTOFF DAMPER (THEN R-7 FOR INSTALLATION). 5. R-7 CAN BE USED IN LIEU OF BUILDING ENVELOPE INSULATION LEVEL IF: DEDICATED OUTSIDE AIR S tSTEM:. � o` o1 aiiy adopted cue or ordinance. Receipt AND LESS THAN 2,800 CFM. el Lpproveci Field APN NUMBER 0223100040 LEGAL DESCRIPTION ANDOVER INDUSTRIAL PARK #2 PORTION TAXABLE REVISIONS No chances shalt be made to the scope of work without prior approval of Tukwila Building Division. MT:: revisions will require a new plan submittal and may include additional plan review fees 30 Andover Part E, ea 9818 VICINITY MAP NO SCALE FILE COPY It No. or rr►view approval is subject to errors and omissions. .ST OF, of construction documen`s does not authorize PIPE INSULATION (INCHES) LAST UPDATED: 01/1./107 a SERVICE FLUID TEMP T INSULATION CONDUCTIVITY NOMINAL PIPE DIAMETER (IN) CONDUCTIVITY RANGE MEAN TEMP RATING °F RUN -OUTS UP TO 2 1 & LESS >1 TO 2 >2 TO 4 >4 TO 6 >6 HWS&R 141-200 0.25-0.29 125 0.5 1.5 1.5 1.5 1.5 1.5 HWS&R 105-140 0.24-0.28 .100 0.5 1.0 1.0 1.0 1.5 1.5 CHWS&R 40-45 0.23-0.27 75 0.5 0.5 0.75 1.0 1.0 1.0 CHWS&R <40 0.23-0.27 75 1.0 1.0 1.5 1.5 1.5 1.5 CDWS&R 40-45 0.23-0.27 75 0.5 0.5 0.75 1.0 1.5 1.0 CONDENSER WATER (FOR NON -ECONOMIZER SYSTEMS -INSULATION IS NOT REQUIRED) 744 7-ial City Of lbkwila ILDING DIVISION SITE MAP REVIEWED FOR CODE COMPLIANCE APPROVED APR 18 2013 L City of Tukwila BUILDING DIVISION RECEIVED ITY OF TUKWILA APR 1 2 2013 PERMIT CENTER ISSUE FOR PERMIT Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ ANDOVER BUILDING 130 ANDOVER PARK EAST TUKWILA, WA 98188-2909 Revisions 04/12/13 MG ISSUE FOR PERMIT No. Date By Description Design Design Team MG Drawn FP Checked DN Scale AS NOTED Drawing Number C-0375-00379 Project Number 1 1-1 3-00379 Issue Date 04/12/13 LEGEND, ABBREVIATIONS, GENERAL NOTES & SHEET INDEX - HVAC M0.00 1ST FLOOR PLAN -HVAC SCALE: 1 /8" = DESIGN NOTES: 0 REPLACE INLET AIR VALVES ON EXISTING VAV'S (TYPICAL 7 0 REPLACE CONTROL VALVES AT ALL EXISTING RADIATORS. 0 INTERLOCK VAV BOX & RADIATOR OPERATION - BY CONTROLS CONTRACTOR.' X113- Obb • REVIEWED FOR ODE ARPROV ®GE APR 18 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA APR 1 2 2013 PERMIT CENTER Hermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ ANDOVER BUILDING 130 ANDOVER PARK EAST TUKWILA, WA 98188-2909 Revisions _ 04/12/13 MG ISSUE FOR PERMIT No. Date By Description Design Design Team MG Drawn FP Checked DN Scale AS NOTED Drawing Number C-0375-00379 Project Number 11 —1 3-00379 Issue Date 04/12/13 1ST FLOOR PLAN - HVAC M2.01 2ND FLOOR PLAN -HVAC SCALE: 1/8" = 1'—O" DESIGN NOTES: 0 REPLACE INLET AIR VALVES ON EXISTING VAV'S (TYPICAL 11). CD REPLACE CONTROL VALVES AT ALL EXISTING RADIATORS. 0 INTERLOCK VA/ BOX & RADIATOR OPERATION - BY CONTROLS CONTRACTOR. REVIEWED FOR QpDE.COMPLIANCE APPROVED APR 18 2013 RECEIVED CITY OF TUKWILA APR 1-2 2013 PERMIT CENTER ISSUE FOR PERMIT ermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACL005BJ ANDOVER BUILDING 130 ANDOVER PARK EAST TUKWILA, WA 98188-2909 Revisions 04/12/13 MG ISSUE FOR PERMIT No. Date By Description Design Team Design MG Drawn FP Checked DN Scale AS NOTED Drawing Number C-0375-00379 Project Number 1 1-1 3-00379 Issue Date 04/12/13 2ND FLOOR PLAN - HVAC M2.02 • DESIGN NOTES: REPLACE INLET AIR VALVES ON EXISTING VAV'S (TYPICAL 10). REPLACE CONTROL VALVES AT ALL EXISTING RADIATORS. 0 INTERLOCK VA/ BOX & RADIATOR OPERATION BY CONTROLS CONTRACTOR. EXISTING DRAFT STO P (TYPICAL) 3RD FLOOR PLAN - HVAC SCALE: 1/8" =1'— lAk3---0 (DO REVIEWED FOR ODE COMPLIANCE APPROVED APR 18 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA ISSUE FOR PERMIT 1 2 2013 PERMIT CENTER ermanson Hermanson Company LLP 1221 2nd Avenue North Kent, Washington 98032 Tel: (206) 575-9700 Fax: (206) 575-9800 www.hermanson.com Contractor Reg #: HERMACLOO5BJ ANDOVER BUILDING 130 ANDOVER PARK EAST TUKWILA, WA 98188-2909 Revisions 04/12/13 MG ISSUE FOR PERMIT No. Date By Description Design Team Design MG Drawn FP Checked DN Scale AS NOTED Drawing Number C-0375-00379 Project Number 11-13-00379 Issue Date 04/12/13 3RD FLOOR PLAN - HVAC M2..