HomeMy WebLinkAboutPermit M13-072 - NORMED - REPLACE ROOF TOP UNITSNORMED 4320 S 131 PL M13-072 City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 7349200095 4320 S 131 PL TUKW Project Name: NORMED Permit Number: M13-072 Issue Date: 05/06/2013 Permit Expires On: 11/02/2013 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: NORMED SHAW PTN PO BOX 3644 , SEATTLE WA 98124 ALEX BURKHART 727 S KENYON ST , SEATTLE WA 98108 ALEXB @E VERGREENHVAC. C OM EVERGREEN REFRIGERATION LLC 727 S KENYON ST , SEATTLE WA 98108 Contractor License No: EVERGRL954R2 Phone: 206 763-1744 Phone: 206 763-1744 Expiration Date: 01/06/2014 DESCRIPTION OF WORK: INSTALLATION OF (4) ROOFTOP UNITS, (7) EXHAUST FANS, DUCTWORK, AND GRILLES/DIFFUSERS. REVISION #1: ADD ADDITIONAL ROOFTOP UNIT WITH GRILLES AND DIFFUSERS FOR A TOTAL OF (5). Value of Mechanical: $47,853.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $771.56 International Mechanical Code Edition: 2009 Date: J `J-3 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. 5173/1 Signature: (t/' Date: Print Name: keit✓wit- (,- This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. .1....• 16Ar' APIA RA11_1179 Prinforl• f1F-91-91111 • • PERMIT CONDITIONS Permit No. M13-072 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-072 Printed: 05-23-2013 CityTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 7349200095 4320 S 131 PL TUKW Project Name: NORMED Permit Number: M13-072 Issue Date: 05/06/2013 Permit Expires On: 11/02/2013 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: Contractor NORMED SHAW PTN PO BOX 3644 , SEATTLE WA 98124 ALEX BURKHART 727 S KENYON ST , SEATTLE WA 98108 ALEXB @EVERGREENHVAC. C OM EVERGREEN REFRIGERATION LLC 727 S KENYON ST , SEATTLE WA 98108 License No: EVERGRL954R2 Phone: 206 763-1744 Phone: 206 763-1744 Expiration Date: 01/06/2014 DESCRIPTION OF WORK: INSTALLATION OF (4) ROOFTOP UNITS, (7) EXHAUST FANS, DUCTWORK, AND GRILLES/DIFFUSERS. REVISION #1: ADD ADDITIONAL ROOFTOP UNIT WITH GRILLES AND DIFFUSERS FOR A TOTAL OF (5). Value of Mechanical: $42,583.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie xami with, Fees Collected: $710.31 International Mechanical Code Edition: 2009 Date: 3 Led this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not pres3fne to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: (11')7*---- Print Name: Date: 5((/15 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. •A4O fl7fl o..�oa• na_na )A1 PERMIT CONDITIONS Permit No. M13-072 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-072 Printed: 05-06-2013 CITY OF TUKW41 Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. 1'- 012 Project No. Date Application Accepted: Date Application Expires: to��l 1h��3 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 13i -112-6o � S Site Address: 45z-0 1315-± p(, Suite Number: Tenant Name: Wv 'r Mc,d PROPERTY OWNER Name: t"\ * IZ uy.-tai3 y — Address: -7 2i-? C �„ Xe cn �l- � ` State: \A/A_ Zip: cat 01 City: SZ� ila- Name: N/orWkj .51,13A.../PT NI Tukwila Business License No.: Bu3 .-. met 2_117 Address: v), d 1304_ 3 1.1i City: CGjokie State: is,Zip: ,1$12=-1 CONTACT PERSON - person receiving all project communication Name: t"\ * IZ uy.-tai3 y — Address: -7 2i-? C �„ Xe cn �l- � ` State: \A/A_ Zip: cat 01 City: SZ� ila- Phone: ibc_i6,3_kr14 q u iiil Fax: c,b---1 a3 -2,3 B`t Email: A .._,,Joe e'j1v.44,1,,vn-c.,,,, Floor: New Tenant: ❑ Yes .. No MECHANICAL CONTRACTOR INFORMATION Company Name: h �_� �Y`�fr1 � cel'" te--A-t D i--1. Address: -2T/ Sam k'.^,1°� st - City: se- State: Liis,Zip: 12 l 1,g Phone: -4c_-163 _ l-Z`_i,..i. Fax: 201°_763 - 23t et Contr Reg No.: .v 6r12i154i2Z Exp Date: 1 /c /H. Tukwila Business License No.: Bu3 .-. met 2_117 Valuation of project (contractor's bid price): $ 853.0 Describe the scope of work in detail: T✓►3aZuuet-il" L NAV vvvt'kj St,wn Use: Residential: New ❑ Replacement ❑ Commercial: New [/ Replacement ❑ wrt•J T"..714-.)/ d� , Fuel Type: Electric ❑ Gas 12( Other: H:\Applications\Forms-Applications On Line \2011 Apphcations\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm ti Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Ww4"4S Print Name: / \`€A ve1't' Mailing Address: 12'1 Su keitLt° v' Date: \A (11/1 Day Telephone: 6 7 `i e`"l . 2.-y7 City H:Wpplications\Fors-Applications On Line \201 I Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh State Zip Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 7349200095 Address: 4320 S 131 PL TUKW Suite No: Applicant: NORMED RECEIPT Permit Number: M13-072 Status: ISSUED Applied Date: 04/19/2013 Issue Date: 05/06/2013 Receipt No.: R13-01721 Initials: WER User ID: 1655 Payment Amount: $61.25 Payment Date: 05/23/2013 10:39 AM Balance: $0.00 Payee: EVERGREEN REFRIGERATION LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 005946 61.25 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 49.00 000.345.830 12.25 Total: $61.25 PrintMrl• 05-73-9013 C , of Tukwila, • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www. ci. tukwila. wa. us SET RECEIPT RECEIPT NO: R13-01367 Initials: JEM Payment Date: 04/19/2013 User ID: 1165 Total Payment: 899.31 Payee: EVERGREEN REFRIGERATION, LLC SET ID: S000001967 SET NAME: Tmp set/Initialized Activities SET TRANSACTIONS: Set Member Amount EL13-0366 92.40 M13-072 710.31 PG13-057 96.60 TOTAL : TRANSACTION LIST: Type Method Description Amount Payment Check 005901 899.31 TOTAL: 899.31 ACCOUNT ITEM LIST: Description Account Code Current Pmts ELECTRICAL PERMIT - NONR GAS - NONRES MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.101.00.0 000.322.103.00.0 000.322.102.00.0 000.345.830 92.40 96.60 568.25 142.06 TOTAL: 899.31 INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 .12_ (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: QO R Type of Inspection: PIs) A 1— Address: H. --2.L.) 3 131't_ Date Called: Special Instructions: Date Wanted: 7-- • 1--7-- i 3 ain: (13,:� Requester: Phone No: 1R,Approved per applicable codes. Corrections required prior to approval. COMMENTS: t (1 --7,Q41 I n s pectdr: IA AAA2-7 t Date: .?_ I% -f RE SPECTION FEE REQUt ED. Prior to nelt inspection. fee must be pard at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. f3 01 Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Pro'ec : (Komi As81,- Type of Inss ec1in IA III A IP 1 o cJ c. ..h ,1/4uS; ms Address: 2,0 (3 / j_-. ,L... Date Ca d: L m ecA Special Instructions: 2 Tvs ,8-' %tip _ Date Wanted: r 7 '5i. --_ p. Requester: Phone No: ElApproved per applicable codes. Corrections required prior to approval. COMMENTS: (Komi As81,- 1-43A'A..-.: r� IA III A IP 1 o cJ c. ..h ,1/4uS; `7-0 „vT .•i 'gid/—% AeeA ,Al l Mt. _. i INSPECTION NO. INSPECTION RECORD Retain a copy with permit n113-072._ PERMIT NO. • CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: NORM .. Type of Inspection: R t‘ 6H - tv Address: L O S. 131 PL Date Called: Special Instructions: Date Wanted: CO _ o2 -g — i 3 .m. p.m. Requester: Phone No: BOG- 679 - 3t37 Approved per applicable codes. Corrections required prior to approval... -7 COMMENTS: _ ; � - �i p /t✓ (b C_211 �-1 ►i su h-410-).) _ ;1) 0 ,/e\k9(/ C.)3 1,1k, ns!ect• : Datg: _ Fj 2_3--r3 SPECTION FE REQUIRED. Prior (o next inspection. fee must be id at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION. RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 e, (206) 431-3670 Permit Inspection Request Line (206) 431-2451 '` sa0) No 3 - Z Project: NO f t.> Typ of Inspection: I�d (.) C,{". _ —C- JU Me cal Add ess:n n j T 5; PL Date Called: Special Instructions: Date Wanted:, { �-a.m_ (9 p.m. Requester: Phone No. ❑ Approved per applicable codes. Corrections required prior to approval. COMMENTS: Q A . .co 14- 1'0 SL(Li(iE i Date FEtNSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Pro je t: l ivrktk_ Di A______ Typ f Inspection: 0&t :.J tiled, Addres2,0 L • I 1 Pr Date Called: Special Instructions: ,) V '(� /7�-� Date Wanted:. Requester: P?amu—�ro`ir`? Approved per applicable codes. Corrections required°prior to approval. COMMENTS: Di A______ r 0 v____( ‘ `= . �,o 0 J - 0 n (A 1 \< (C 'TT:to K_ '. Al--� SLJ (A--'1 .N-' 5' i ! dr. 'el J, f #0..1 1-x- / Inspptor: Datt-2`3. \t n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. EVERGREEN REFRIGERATION, LLC 727 S KENYON ST. SEATTLE, WA. 98108 206-763-1744 CONTR. # EVERGRL954R2 Pit 13 -- 2- tV e t M. TEST AND BALANCE REPORT Project: NorMed Evergreen Job #: 513196 Date: May 16, 2013 Location: 4320 S 131st Place Tukwila, WA 98124 Engineer: EVERGREEN REFRIGERATION LLC Evergreen Refrigeration LLC, has balanced the system described in accordance with the plans, specifications, and within the limitations of the equipment. The testing, balancing, and adjusting has been performed in accordance with industry standards. The results of these tests are herein recorded. Commissioning Technician: Date completed: --itg /13 AIR OUTLET TEST REPORT - SUPPLY EVERGREEN REFRIGERATION, LLC Page 1 Project: NorMed Job #: 513196 Date: 5/16/13 Unit # Area Served Outlet Design Target Preliminary Final No Type Size C.F.M. C.F.M. C.F.M. C.F.M. C.F.M. RTU -1 S1.1 MCD 10 300 340 aro 310 S1.2 MCD 10 300 35'0 3 Zv 32-0 S1.3 MCD 10 300 710 2 c 2°© S1.4 MCD 10 300 2G5 2•0'5". Z$5' Total CFM 1200 /2e)c OSA CFM 240 2.4-1 l Tonnage 3 RTU -2 S2.1 MCD 10 400 380 '3b0 y go S2.2 MCD 10 400 34 o L-130 yo® S2.3 MCD 8 200 270 330 /80 S2.4 MCD 8 200 1(,$ /65 22a Total CFM 1200 /2y 0 OSA CFM 240 248 Tonnage 3 RTU -3 S3.1 MCD 10 400 3'40 3l00 390 S3.2 MCD 10 400 390 yto 1-125 S3.3 MCD 10 400 34.0 380 390 S3.4 MCD 10 400 3-75 s-1 to goo S3.5 MCD 10 250 )80 Zo 5 230 S3.6 MCD 8 150 /36 /"45" /LIT Total CFM 2000 / jaO OSA CFM 400 3140 Tonnage 5 AIR OUTLET TEST REPORT - SUPPLY Page -2 Project: NorMed Job #: 513196 Date: 5/16/13 Unit # Area Served Outlet Design Target Preliminary Final No Type Size C.F.M. C.F.M. C.F.M. C.F.M. C.F.M. RTU -4 S4.1 MCD 8 200 1(,o ) 75 180 S4.2 MCD 6 50 Coo 5 3a S4.3 MCD 6 50 55 57> Sa S4.4 MCD 8 200 /26" /8o /80 S4.5 MCD 10 250 / 5b /95 25 7) S4.6 MCD 10 250 r/5- 2,5 240 S4.7 MCD 10 250 2.10o 2-15 2.yS S4.8 MCD 10 250 21.0V 30o 240 S4.9 MCD 10 250 A415- 25-' 250 S4.10 MCD 10 250 235 255' 255" Total CFM 2000 / 5(00 OSA CFM 400 .392. Tonnage 5 RTU -5 S5.1 MCD 10 300 310 -- -io S5.2 MCD 8 150 /4,o - /1,o S5.3 MCD 8 200' - 205 S5.4 MCD 8 150 /1045 - /65- G$S5.5 S5.5 MCD 8 200 216- - 215 S5.6 MCD 8 150 lloo - )60 Total CFM 1150 1215 OSA CFM 230 2-H3 Tonnage 3 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 'Project Info FILECOPY ...,en 00.., Project Address 4320 S 131st PI. Date 5/6/2013 Tukwila, WA 98188 For Building Dept. Use Applicant Name: Evergreen Refrigeration Applicant Address: 727 S. Kenyon St. Seattle, WA 98108 Applicant Phone: 206-763-1744x247 Project Briefly describe system type Description mechanical and features. Plans Installation of five (5) rooftop units and seven (7) exhaust fans. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 -' Includes Compliance Option QQ Simple System Q Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH-SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N RTU -1 Lennox RGA036S4D 37500 240 13 N/A Econmizer N RTU -2 Lennox KGA036S4D 37500 240 13 N/A Econmizer N RTU -3 Lennox KGA060S4D 61800 400 13 N/A Econmizer N RTU -4 Lennox RGA060S4D 61800 400 13 N/A Econmizer N RTU -5 Lennox RGA036S4D 37500 240 13 N/A Econmizer N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.' Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency's Heat Recovery Y/N RTU -1 Lennox RGA036S4D 84000 240 105000 84000 80 N RTU -2 Lennox RGA036S4D 84000 240 105000 84000 80 N RTU -3 Lennox RGA060S4D 52000 400 65000 52000 80 N RTU -4 Lennox RGA060S4D 52000 400 65000 52000 80 N RTU -5 Lennox RGA036S4D 84000 240 105000 84000 80 N Fan Equipment Schedule VIEWED FOR FlIV11L�J`IV�i Equip. ID Equip Type Brand Name' Model No.' CFM SP' HP/BHP Flow ,' BF -1 Broan L150 130 0.375" 0.22 CV J`IV APPRv��'nyicq BF -2 Broan QTR110 90 0.2" 0.10 CV Ceiling 8F-3 Broan L150 130 0.375" 0.22 CV ",=<Yin1 0 2013 8F-4 Broan L150 130 0.375" 0.22 CV • Ceiling EF -5 Broan L150 130 0.375" 0.22 Cv ling 8F-6 Broan L200 200 0.125" 0.28 Cv BUI Ar,r&it DIVISION ON BF -7 RECEIVE} n L200 200 0.125" 0.28 CV -:._._,_.. !UDE. TU1WIldAccording to Table 14-1A through 14-1G. 3 If required. 4 COP HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow controltypes: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from Section 1433. MAY 0 6 2013 PERMIT CENTER Nn I 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 System Description See Section 1421 for full description of Simple System qualifications. All Systems: .i No humidification? ❑✓ No Reheat? If Heating/Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ✓ <=84,000 Btuh? El Economizer ❑ Air cooled? .i Packaged sys? ❑<=135,000 Btuh? ❑ Cooling Cap <=15 Btuh/ft2? ❑ Heating Cap. > 0 & <=10 Btuh/ft2? If Heating Only: ❑ <1000 cfm? ❑<30% outside air? ❑ Heating Cap. <=10 Btuh/ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Yes ( START ) ap <=15 Heat/Cool Eq. with Cap <=10 , or Yes Heating/Cooling or Cooling Only Heating Only Reference \ Section 1421 J Yes Yes Yes alifies Economizer Exception tion 1 No Yes Yes Simple System Allowed (section 1420) T Use Complex ► Systems (section 1430) Complex Systems Refer to MECH-COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist MECH-CHK for Nonresidential and Multifamily Residential Revised December 2010 200 • Washington State Energy Code Compliance Forms Project Address 4320 0 131st P1. Date 5/6/2013 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401-1424) 1411 Equipment Performance Yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M1 N.A. 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & jacket loss N.A. 1411.1 Air-cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water-cooled chiller Full -load and NPLV values adjusted for any non-standard conditions N.A. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule N.A. 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls N.A. 1412.1 Temperature zones Indicate locations on plans Yes 1412.2 Deadband control Indicate 5 degree deadband minimum M1 N.A. 1412.3 Humidity control Indicate humidistat Yes 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback M1 N.A. 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage N.A. 1412.4.2 Optimum Start Indicate optimum start controls N.A. 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule N.A. 1412.6 Combustion heating Indicate modulating or staged control Yes 1412.7 Balancing Indicate balancing features on plans M1 N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high -occupancy areas N.A. 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. N.A. 1422 Thermostat interlock Indicate thermostat interlock on plans N.A. 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. Yes 1413.1 Air Econo Operation Indicate 100% capability on schedule M1 N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N.A. 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. N.A. 1413.3 Integrated operation Indicate capability for partial cooling N.A. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems N.A. 1414.1 Duct sealing Indicate duct design pressures, sealing, and testing requirements N.A. 1414.1.2 Low press. duct test Indicate applicable low pressure duct systems shall be leak tested N.A. 1414.1.3 High press. duct test Indicate high pressure duct systems shall be leak tested, and identify the location of this ductwork on plans N.A. 1414.2 Duct insulation Indicate R -value of insulation on duct 1415 Piping Systems N.A. 1415.1 Piping insulation Indicate R -value of insulation on piping 1416 Completion Requirements Yes 1416.3.2 System Balancing Indicate air and water system balancing requirements M1 Yes 1416.3.3 Functional Testing Provide sequence of operations and test procedures. M1 Yes 1416.3.4 Documentation Indicate O&M manuals, record drawings, staff training M1 Yee 1416.3.5 Comm. Report , Indicate requirements for final commissioning report M1 N.A. 1416.4 Compliance Chklist Submit to building official upon substantial completion. Yea Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist Continued MECH-CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address 4320 s 131ec Pl. Date 5/6/2013 The following_ information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440-1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R-10 insulation under tank N.A. 1442 Shut-off controls Indicate automatic shut-off of circulators or heat trace N.A. 1443 Pipe Insulation Indicate R -value of insulation on piping N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. 1460 Heated Pools N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R-12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction COLD STORAGE (Sections 1460-1465) 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sections 1401-1424 or 1440-1465 , provide explanation: 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH-SUM 2009 WasAington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Info ,.._Pa RE`J9E b. FO`r� j Address 4320 S 131st PI. Date 4/12/2013 r Tukwila, WA 98188 For Building Dept. Use CODE C Ap pR*VE®Applica WV o � 201 t Name: Evergreen Refrigeration t 727S. Kenyon St. Seattle, WA 98108 Applicanpplica Phone: los7s3-1744x247. Project Briefly describe system type De ription t-chanic lity O1 Tu and f; ayeyiLDI�� D Plans iidnst.Iation of four (4) rooftop units and seven (7 exhaust fans. as101�1 ''� LE Copy Drawings must contain notes requireing compliapce with commissioning requirements - Section 1416 -' Includes Compliance Option QQ Simple System 0 Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH-SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery Y/N RTU -1 Lennox KGA060S4D 61800 400 13 N/A Econmizer N RTU -2 Lennox KGA036S4D 37500 240 13 N/A Econmizer N RTU -3 Lennox KGA060S4D 61800 400 13 N/A Econmizer N RTU -4 Lennox KGA060S4D 61800 400 13 N/A Econmizer N Heating Eq iipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency° Heat Recovery Y/N RTU -1 Lennox KGA060S4D 52000 400 65000 52000 80 N RTU -2 Lennox KGA036S4D 84000 240 105000 84000 80 N RTU -3 Lennox KGA060S4D 52000 400 65000 52000 80 N RTU -4 Lennox KGA060S4D 52000 400 65000 52000 80 N Fan Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 CFM SP' HP/BHP Flow Controls Location of Service EF -1 Broan L150 RECEIVED 130 0.375" 0.22 CV Ceiling EF -2 Broan QTR1GITY OF TUKWILA° 0.2" 0.10 CV Ceiling EF -3 Broan L150 130 0.375" 0.22 cv Ceiling EF -4 Broan L150 APR 1 9 2013 130 0.375" 0.22 CV Ceiling EF -5 Broan L150 0.375" 0.22 CV Ceiling EF -6 Broan �+ L200 PERMIT CENTEEOO � p130 0.125" 0.28 CV Ceiling EF -7 Broan L200 200 0.125" 0.28 CV Ceiling 'If available. 2 As tested according to Table 14-1 A through 14-1 G. 3 If required. ° COP HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume. (CV), or variable speed (VS). 6 Exception number from Section 1433. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH-SUM 2009,Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 System Description See Section 1421 for full description of Simple System qualifications. All Systems: ✓ No humidification? ✓ No Reheat? If Heating/Cooling or Cooling Only: ❑ Constant vol? ❑ Split system? ✓ <=84,000 Btuh? ✓ Economizer ❑ Air cooled? ✓ Packaged sys? ❑<=135,000 Btuh? ❑ Cooling Cap <=15 Btuh/ft2? ❑ Heating Cap. > 0 & <=10 Btuh/ft2? If Heating Only: ❑ <1000 cfm? ❑<30% outside air? ❑ Heating Cap. <=10 Btuh/ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. CSTART ap <=15 Heat/Cool Eq. with Cap <=10 Yes Yes , or /ft2 ? Heating/Cooling or Cooling Only Heating Only Reference Section 1421 Yes Yes Yes Yes Simple System Allowed (section 1420) alifies Economizer Exception tion 1 Yes Use Complex Systems (section 1430) Complex Systems Refer to MECH-COMP Mechanical Complex Systems for assistance in determining which Complex Systems requirements are applicable to this project. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans State Energy Code Compliance Forms Checklist MECH-CHK for Nonresidential and Multifamily Residential Revised December 2010 2009 Washington Project Address 4320 S 131st Pl. Date 4/12/2013 The following1information is necessary to check Washington State Nonresidential Energy Code. a mechanical permit application for compliance with the mechanical requirements in the Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes HVAC REQUIREMENTS (Sections 1401-1424) 1411 Equipment Performance Yee 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M1 N.A. 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & jacket loss N.A. 1411.1 Air-cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water-cooled chiller Full -load and NPLV values adjusted for any non-standard conditions N.A. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule N.A. 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls N.A. 1412.1 Temperature zones Indicate locations on plans Yes 1412.2 Deadband control Indicate 5 degree deadband minimum M1 N.A. 1412.3 Humidity control Indicate humidistat Yes 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback Mi N.A. 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage N.A. 1412.4.2 Optimum Start Indicate optimum start controls N.A. 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule N.A. 1412.6 Combustion heating Indicate modulating or staged control Yes 1412.7 Balancing Indicate balancing features on plans Mi N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high -occupancy areas N.A. 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. N.A. 1422 Thermostat interlock Indicate thermostat interlock on plans N.A. 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. Yee 1413.1 Air Econo Operation Indicate 100% capability on schedule Mi N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N.A. 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg load & equipment performance data. N.A. 1413.3 Integrated operation Indicate capability for partial cooling N.A. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems N.A. 1414.1 Duct sealing Indicate duct design pressures, sealing, and testing requirements N.A. 1414.1.2 Low press. duct test Indicate applicable low pressure duct systems shall be leak tested N.A. 1414.1.3 High press. duct test Indicate high pressure duct systems shall be leak tested, and identify the location of this ductwork on plans N.A. 1414.2 Duct insulation Indicate R -value of insulation on duct 1415 Piping Systems N.A. 1415.1 Piping insulation indicate R -value of insulation on piping 1416 Completion Requirements Yes 1416.3.2 System Balancing Indicate air and water system balancing requirements Mi Yes 1416.3.3 Functional Testing Provide sequence of operations and test procedures. Mi Yes 1416.3.4 Documentation Indicate O&M manuals, record drawings, staff training M1 Yes 1416.3.5 Comm. Report Indicate requirements for final commissioning report M1 N.A. 1416.4 Compliance Chklist Submit to building official upon substantial completion. Yee Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist Continued MECH-CHK 2009.Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised December 2010 Project Address 4320 S 131st P1. Date 4/12/2013 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington -tate Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440-1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R-10 insulation under tank N.A. 1442 Shut-off controls Indicate automatic shut-off of circulators or heat trace N.A. 1443 Pipe Insulation Indicate R -value of insulation on piping N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. 1460 Heated Pools N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R-12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction COLD STORAGE (Sections 1460-1465) 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sections 1401-1424 or 1440-1465 , provide explanation: C T ENGINEERING INC. FILE COPY w STRUCTURAL CALCULATIONS RTU's NorMed Building 4320 S 131st Place Tukwila, WA Contractor: Evergreen Refrigeration, Inc. Scope of Work:. Structural Review for new RTU's - Total of five units Code: IBC 2009 Loads: Roof snow 25 PSF Unit weights as noted in calculations Seismic SDS = .99 RECEIVED CITY OF TUKWILA MAY 0 6 2013 PERMIT CENTER Structural Engineers 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 2854512(V) (206) 285-0618(F) REVIEWED FOR CODE COMPLIANCE APPROVED MAY 10 2013 City of Tukwila BUILDING DIVISION 05/06/2013 REVISIONO._L kAt?rOl'Z 66'-8" 30 0" 25'-0" 80'l-0" 40'-0" 40'=0" it/A;rZ as �a1.Pi/V /°;47f -ii G Also/ 1 lo; AiJ' N , C T ENGINEERING I N C. Project: _ . - . �, _ , Date: 180 Nickerson St. Suite 302 Seattle, WA 98109 t — (206) 285.4512 PAX: Client: Page Number: (206) 285-0618 , I ' I Gv E8 k -I,I Fo/24/xl6 *i r'R jln0. �., . �... ,. , / .. 1 1 - I. . it _ L4 HOt ea,Nr A.v#1v• /_ 1 _ . TO P CH -Ago O,4iYEL ..pe/NT SES ibGGG',, /N!, Pornsi7G .• 4x6 FF'_ SEE E-2.2 FOR STEEL SIDE Fp'S ® R.T.U. SHEATHING 3x WOOD TS2x4 P.T. CARR W/ Ck) '41' 5 V5 ct205 e..; -elf SIDS 4x6 VERT. BLOCKING ir- 416V JOIST JOIST GIRDER-7...IL SECTION L 2x2x14 EA. SIDE OF WEB SCALE: 3/4" = 1'-0" F • C T E N G 1 N E E' R'I N G ,�I INC, Prolccf: /V6 E)110/,7 /0 IGO/U e, Dote: o Wept,.g 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 VAX: Client: Page Number: (206) 28S-0618 y�Gdii,� ►.% .• $U/1'9//06 ;gig . �Oi d vi��l _SGT: ti'' #. .. 0 ', *fid Aoier ate/ r, 3 ee vAe/ '� _ 07'1 ,J /PG f r Iwo?114IF 107 '5 te?7i-ibv 797. y4 ow Awe*. C T ENGINEERING Project: %vim/'o V49//yy I N C. Date: ,/7 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 PAX: Client: Page Number: (206) 285-0618 41r; eoPo S�iSsfrG /vv : opoormoviewe . . 2 ev/ 7v 4a4,0 w/ (3) '9-$P .0e4tevls/$ Gni Sia Rfrn r_fural Enninnnrn SHEET TITLE: CT PROJECT # : 2009 IBC SEISMIC OVERVIEW 2009 IBC RTU SEISMIC OVERVIEW 13084 NorMed Building Step # 2009 IBC ASCE 7-05 1. OCCUPANCY CATEGORY TYPE = II Table 1604.5 Table 1-1 2. IMPORTANCE FACTOR IE = 1.00 N/A Table 11.5-1 3. Site Class S.C. = D 1613.5.5 Section 11.4 Table 1613.5.5 Table 11.4-2 4. 0.2 Sec. Spectral Response Ss = 1.48 Figure 1613.5(1) Figure 22-1 5. 1.0 Sec. Spectral Response S1= 0.51 Figure 1613.5(2) Figure 22-2 Lat 47.49 Long -122.28 6. Site Coefficient (short period) Fa = 1.00 Table 1613.5.3(1) Table 11.4-1 7. Site Coefficient (1.0 second) Fv = 1.50 Table 1613.5.3(2) Table 11.4-2 SMs=Fa*Ss SM1=Fv*Si SDs = 2/3 * SMS SDI = 2/3 * SM1 SMs = 1.48 SM1 = 0.77 Sips = 0.99 SDI = 0.51 EQ 16-37 EQ 11.4-1 EQ 16-38 EQ 11.4-2 EQ 16-39 EQ 11.4-3 EQ 16-40 EQ 11.4-4 2009 IBC SEISMIC DEMANDS ON NON-STRUCTURAL COMPONENTS PER ASCE 7-05 D e SDS = 0.99 Wp 800 lbs Ap 2.5 Table 13.6-1 Air -side HVAC Ap 2.5 Table 13.6 -1 -flexible; footnote a (applies only if Ap=1) Rp 6.0 Table 13.6-1 Air -side HVAC; if "wet -side", use 2.5 Ip 1.0 Section 13.1.3 z 30.0 ft h 30.0 ft z/h 1 Fp Seismic Design Force Check: Fp 395 Ibs Eq: 13.3-1 Fp 1263 Ibs Eq: 13.3-2 Fp 2371bs Eq: 13.3-3 Fp 395 lbs Eq: 13.3-1 (flexible) sign Load Rigid Fp 395 Ibs lbs Load divided by 1.4 for ASD alterantive 282 Design Load Flexible Fp 395 282 lbs lbs Load divided by 1.4 for ASD alterantive P:\13084 NorMed RTU\20091BC_RTU Lateral.xls 7/8 Overturning Calculation SHEET TITLE: 2009 IBC SEISMIC DEMANDS ON NON-STRUCTURAL COMPONENTS PER ASCE 7-05 CT PROJECT # : 13084 NorMed Building H= RTU Unit C L= 7 FT Overturning Calculation: Mot= Fp*H Mot= 845.71 Ib -ft Overturning Calculation: Mot= Fp*H Mot= 845.71 Ib -ft Resisting Overturning: Mr=0.6*W p*U2 Mr= 3360 Ib -ft Net M= 2514 Ib -ft Net Uplift Force = 359 Ib (positive means no uplift) Resisting Overturning: Mr=0.6*W p*B/2 Mr= Net M = Net Uplift Force = (positive means no uplift) 1440 Ib -ft 594 Ib -ft 198 Ib P:\13084 NorMed RTU\20091BC RTU Lateral.xls 8/8 CT ENGINEERING INC. STRUCTURAL CALCULATIONS 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512(V) (206) 285-0618(F) RTU's FILE COPY NorMed Building 4320 S 131st Place P8 tof. r\A -o Tukwila, WA phM Contractor: Evergreen Refrigeration, Inc. Scope of Work:. Structural Review for new RTU's - Total of four units Code: IBC 2009 Loads: Roof snow 25 PSF Unit weights as noted in calculations Seismic SDs = .99 RECEIVED CITY OF TUKWILA APR 1 9 2013 PERMIT CENTER Structural Engineers REVIEWED FOR CODE COMPLIANCE APPROVED MAY 022013 City of Tukwila BUILDING DIVISION 04/18/2013 M 13 -0'I 2_ C-2. [2 '-61/4" • =CIAL N O J O 32G 5N 18K SPECIAL 0• 32G 4N 18K SPECIAL V A-2.3 B-2.3 -I 66'-8" 23'-10 4$(p, 71? [23' 30' I-0" 0 12T..1 PEt2- me ' 25'-0" 0' 40'-0" 40'-0" 0 �t- d!2 fri�p et)/W,rn9 /moi Piiwiiiii7 /4lJ CT ENGINEERING 1 N C. Project *\ Client: Date: 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 FAX: Page Number: (206) 285-0618 1 IN Eg k`E-I.J 4.4/N6 Rine. 1(1./{z7t ,da /NT C� leE/ 7VZ, r7 AI &'' f r2M 1. TOP cm''e) O+4/YEL PG/A/T Z SEE' �bu.�rr /i�l• , , f CgfitZ. 14/E8 /6,1( in4914 */Ne7 0•.....•.....1 c _.i........- 4x6 fE SEE E-2.2 FOR STEEL SIDE feS ® R.T.U. SHEATHING 3x WOOD I MECH. UNIT RE: PLAN MAX. WT. = acc 2x4 P.T, CARR �) '4" s u5 /4- crtr 5 6 -ctf 5/QS 4x6 VERT. BLOCKING 4-3 110. 416V JOIST JOIST GIRDER—V/IL SECTION 8 L 2x2x1/4 EA. SIDE OF WEB SCALE: 3/4' = 1'-0" C T ENGINEERING NC. Project: �WO/LNG/2%d/G17ev y Date: ¢(' 740/3 20/ 180 Nickerson St. Suite 302 Seattle, WA 98109 (206) 285-4512 PAX: Client: Page Number: (206) 285-0618 pgu� Ona O `,r' rLru 3 49-320•5 /3,r',e~ iliem444 i4- 24'&9 IgG' SE_ fzO. G60w,"e6 546 - . a,, q9' 4 L o,r/ 56riMPG - 90/-aZ z ,45v//N as e (:'•or/ 77t? UJB ty'i .....y -/'T - G ds �2C,rJ� 0/r41 '1.7e4, /1 1/1-1/T' GaG/-17d7 `sem i v,V/ Fiew/J 074 i°G#f vjr : `re -7 lT10,-)i- /5 : tel 7 t, ov 44- 7 97,11` Structural Engineers C T ENGINEERING Project: /1414 /1142 ,,50/1,e2/4' 1 N C. Date: "// 180 Nickerson St. Salle 302 Seattle, WA 98109 (206) 285-4512 PAX: Client: Page Number: (206) 285-0618 Structural Engineers SHEET TITLE: CT PROJECT # : 2009 IBC SEISMIC OVERVIEW 2009 IBC RTU SEISMIC OVERVIEW 13084 NorMed Building Step # 2009 IBC ASCE 7-05 1. OCCUPANCY CATEGORY TYPE = II Table 1604.5 Table 1-1 2. IMPORTANCE FACTOR IE = 1.00 N/A Table 11.5-1 3. Site Class S.C. = D 1613.5.5 Section 11.4 Table 1613.5.5 Table 11.4-2 4. 0.2 Sec. Spectral Response Ss = 1.48 Figure 1613.5(1) Figure 22-1 5. 1.0 Sec. Spectral Response S1 = 0.51 Figure 1613.5(2) Figure 22-2 Lat 47.49 Long -122.28 6. Site Coefficient (short period) Fa = 1.00 Table 1613.5.3(1) Table 11.4-1 7. Site Coefficient (1.0 second) Fv = 1.50 Table 1613.5.3(2) Table 11.4-2 SMs=Fa*Ss SMi=Fv*S1 Sips = 2/3 * SMS SD1 = 2/3 * SM1 SMs = 1.48 SM1 = 0.77 SIDS = 0.99 SDI = 0.51 EQ 16-37 EQ 11.4-1 EQ 16-38 EQ 11.4-2 EQ 16-39 EQ 11.4-3 EQ 16-40 EQ 11.4-4 2009 IBC SEISMIC DEMANDS ON NON-STRUCTURAL COMPONENTS PER ASCE 7-05 Sos = 0.99 Wp 800 lbs Ap 2.5 Table 13.6-1 Air -side HVAC Ap 2.5 Table 13.6 -1 -flexible; footnote a (applies only if Ap=1) Rp 6.0 Table 13.6-1 Air -side HVAC; if "wet -side", use 2.5 Ip 1.0 Section 13.1.3 z 30.0 ft h 30.0 ft z/h 1 Fp Seismic Design Force Check: Fp 395 Ibs Eq: 13.3-1 Fp 1263 Ibs Eq: 13.3-2 Fp 237 Ibs Eq: 13.3-3 Fp 395 lbs Eq: 13.3-1 (flexible) Design Load Rigid Fp 395 282 Design Load Flexible Fp 395 282 lbs lbs Load divided by 1.4 for ASD alterantive lbs lbs Load divided by 1.4 for ASD alterantive P:\13084 NorMed RTU\20091BC_RTU Lateral.xls 7/8 Overturning Calculation SHEET TITLE: 2009 IBC SEISMIC DEMANDS ON NON-STRUCTURAL COMPONENTS PER ASCE 7-05 CT PROJECT # : 13084 NorMed Building H= RTU Unit L= 7 FT Overturning Calculation: Mot= Fp*H Mot= 845.71 Ib -ft Overturning Calculation: Mot= Fp*H Mot= 845.71 Ib -ft Resisting Overturning: Mr=0.6*W p*U2 Mr= 3360 Ib -ft Net M= 2514 Ib -ft Net Uplift Force = 359 Ib (positive means no uplift) Resisting Overturning: 1Mr=0.6*Wp*B/2 Mr= Net M = Net Uplift Force = (positive means no uplift) 1440 Ib -ft 594 Ib -ft 198 Ib P:\13084 NorMed RTU\2009IBC_RTU Lateral.xls 8/8 •PERMIT COORD C4P% PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-072 DATE: 05/06/13 PROJECT NAME: NORMED SITE ADDRESS: 4320 S 131 PL Original Plan Submittal Response to Incomplete Letter # _ Response to Correction Letter # X Revision # 1 after Permit Issued DEPARTMENTS: 41- Aic, %.-Cr-(3 uilding Division mi Public Works tps- o . n. 13 ire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete tit Incomplete ❑ DUE DATE: 05/07/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUESITHURS ROUTING: Please Route REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Notation: REVIEWER'S INITIALS: DUE DATE: 06/04/13 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: SERM1T COORD CO% PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-072 DATE: 04/19/13 PROJECT NAME: NORMED SITE ADDRESS: 4320 S 131 ST X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: ilding Division III Public Works Awe /VA Fire Prevention • Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 04/23/13 Not Applicable ❑ Comments: Permit •Cen"'ter Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route 1‹. REVIEWER'S INITIALS: DATE: Structural Review Required ❑ No further Review Required ❑ APPROVALS OR CORRECTIONS: DUE DATE: 05/21/13 Approved ❑ Approved with Conditions k Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: PROJECT NAME: IV O YLIM SITE ADDRESS: 1 1i),9 ‘" lb Pl., PERMIT NO: M ORIGINAL ISSUE DATE: 01S-1/9' REVISION LOG REVISION NO, DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INIT� 1 O - etV -13 6--3 —►3 Summary of Revision: ANC) r) OA 00 pc►L -p( " ut n- `r•/( ) oC DlnMVAN2-I- -j (=5-19—t Received by: M. 113wic66- REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: (please print) REVISION NO. DATE RECEIVED STAFF INITIALS ISSUED DATE STAFF INITIALS Summary of Revision: Received by: please print City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: Plan Check/Permit Number: / _ 1 ' D7 2 - Response Response to Incomplete Letter # Response to Correction Letter # Revision # t after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: No\r Project Address: 1-1'12 5- 1315k -f i ` Contact Person: Ate -1, Ate-1,Phone Number: W.-- 1-1461 frCt - 7 Summary of Revision: A'014.0DV' . 111/Dr'Cs), - I Un - ova T Sacit--4,-4? d,R-61,.k /grA3 4-0d t Sheet Number(s): AA 1 r M 2- , /tit "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit C-nter iqEntered in Permits Plus on RECEIVED "rev r W.WILA MAY 0 6 2013 r'ERMIT CENTER H:\Apphcations\Forms-Applications On Line \2010 Applications \7-2010 - Revision SubnuttaLdoc Revised: May 2011 Contractors or Tradespeopleointer Friendly Page General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name EVERGREEN REFRIGERATION LLC UBI No. 602512953 Phone 2067631744 Status Active Address 727 S Kenyon St License No. EVERGRL954R2 Suite/Apt. License Type Construction Contractor City Seattle Effective Date 1/6/2006 State WA Expiration Date 1/6/2014 Zip 98108 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EVERGHH910J0 EVERGREEN HOME HEATING & ENGY Construction Contractor General Unused 4/20/2009 4/20/2015 Active EVERGI*201D7 EVERGREEN REFRIGERATION INC Construction Contractor General Unused 3/27/1980 7/31/2006 Re- Licensed Business Owner Information Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC Partner/Member 12/22/2005 Bond Amount PATTON, DAVID Partner/Member 01/06/2006 WA15097 PATTON, RODGER Partner/Member 01/06/2006 PATTON, MATTHEW Partner/Member 01/06/2006 TRAVELERS CAS & SURETY CO Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Merchants Bonding Co (Mutual) WA15097 01/01/2012 Until Cancelled $12,000.0012/15/2011 07/29/2012 1 TRAVELERS CAS & SURETY CO 104667361 01/01/2006 Until Cancelled $12,000.00 01/03/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 AMERICAN FIRE AND CASUALTY COM BAW54192293 07/31/2010 07/31/2013 $1,000,000.00 07/29/2012 2 Continental Western Ins Co CWP2640663 07/31/2006 07/31/2010 $1,000,000.00 03/23/2009 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns://fortress.wa.>?ov/lni/bbin/Print.aspx 05/06/2013 COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF THE ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER WA ENERGY CODE (WSEC) SECTION 1416.3.4.2 AN OPERATING MANUAL AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER WSEC SECTION 1416.3.4.1 ALL HVAC SYSTEMS SHALL BE. BALANCED AND A WRITTEN BALANCE REPORT SHALL BE PROVIDED TO THE OWNER PER WSEC SECTION 14516.3.2.1. FOR WAREHOUSES, SEMIHEATED SPACES, AND SIMPLE SYSTEMS (AS DEFINED IN WSEC SECTION 1421): HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.3.3. FOR ALL OTHER SYSTEMS: HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED, SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORD WITH SPECIFICATIONS AND APPROVED PLANS PER WSEC SECTION 1416.3.3. NECESSARY TESTS SHALL BE IDENTIFIED PER WSEC SECTION 1416.3.3; A PRELIMINARY COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE PREPARED PRIOR TO ISSUANCE OF A FINAL CERTIFICATE OF OCCUPANCY PER WSEC SECTION 1416.3.4.1 AND A COMPLETE FINAL COMMISSIONING REPORT OF TEST PROCEDURES AND RESULTS SHALL BE FILED WITH THE OWNER PER WSEC SECTION 1416.4 GENERAL NOTES GA. PACKAGE EQUIPMENT SCHEDULE S C G Q MARK MANF. MODEL TONS. AIRFLOW SP MIN. OSA Motor DRIVE COOLING HEATING ELECTRICAL ; WEIGHT CFM WC CFM Hp STYLE TOTAL SEER EER INPUT OUTPUT AFUE VOLTS PHASE M.C.A. MOCP UNIT ECON CURB TOTAL FILTER SIZES NOTES 90 0.2" 115 171 W '" 'LOCATED` ON CEILING: 1 EF 3 BROAN BTUH 130 0.375" . BTUH BTUH (%) (V) 1 (A) (A) LBS LBS LBS LBS NO. (LxWxD) 1,4 A RTU. 3,4 LENNOX KGA060$4D 5 2000 0.5 400 0.75 DD - 61,800 , 13.0 11.0 65,000. 52,000 80% 460 30 14.0 20 ; ;.. 697 ' 97 100 797 4 16" x 20" x 2". { ) 12 >3 RTU 1,2,5 LENNOX KGA036S4D 3 1200 0.5 240 0:5 DD 37,500 13.0 10:7 105,000 84,000 80% 460 30 11.0 15 630 66 99 729 4 " x 20" 16 x 2" ( ) 1,2,3 NOTE: 1. PACKAGED ROOFTOP UNIT. 2. ALL POWER WIRING (BY E.C.) 3.rPfVIDE 100% O ECONOMIZER & ROOFCURB. EXHAUST FAN SCHEDULE SYMBOL LEGEND MARK MANE. MODEL - CFM S.P. VOLTS PHASE. Hp/A LOCATION NOTES ►;�� DUCT SECTION - RETURN/EXHAUST ra EF 1 BROAN L150 130 0.375" 115 1 1.4 A LOCATED ON CEILING 1 EF 2 BROAN QTR110 90 0.2" 115 171 W '" 'LOCATED` ON CEILING: 1 EF 3 BROAN L150 130 0.375" . 115 1 1.4 A LOCATED ON CEILING 1 EF 4 BROAN L150 130 0.375" 115 1 1,4 A LOCATED ON CEILING 1 EF 5 BROAN L150 130 0,375" 115 1 1,4 A LOCATED ON CEILING 1 EF 6 BROAN L200 200 0,125" 115 1 1.8 A LOCATED ON CEILING 2 EF 7 BROAN L200 200 0.125" 115 1 1.8 A LOCATED ON CEILING 1 NOTE: 1. CONTROLLED BY LIGHT SWITCH 2. ERL TO PROVIDE LINE VOLTAGE THERMOSTAT, OTHERS TO INSTALL SEPARATE PERMIT REQUIRED FOR: I3 echanical &Electrical: irrlyi mbing U as Piping C `y of Tukwila BUILDING DIVISION FILE COPY Permlt No. IA3 "07Z PI!n review approval is subject to errors and omissions. k;: Y T of construction documents does not authorize tr'€:. -tion of any adopted code or ordinance. Receipt n Lpproved Field Copy and ©ones is acknowledged: ByAL Date: 5 /1-3 (13 CIty Of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. i'r : E -visions will require a new plan submittal t..-‘.1 my include additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED MAY 10 2013 el City of Tukwila BUILDING DIVISION DUCTWORK 1.1 ALL DUCT DIMENSIONS ON PLAN ARE CLEAR INSIDE DIMENSIONS, ADD 2" TO EACH DIMENSION TO OBTAIN OUTSIDE DIMENSION. ADD 4"TO EACH DIMENSION IF DUCTWORK IS ON THE EXTERIOR OF BUILDING. 1.2 THE FIRST NUMBER ON ALL DUCT DIMENSIONS IS THE WIDTH AND THE SECOND NUMBER IS THE HEIGHT. 1.3 MATERIALS WITHIN DUCTS OR PLENUMS SHALL HAVE A FLAME SPREAD RATING LESS THAN 25 AND FLAME SMOKE DEVELOPMENT RATING LESS THAN 50, PER IMC 602.2.1. 1.4 SEAL ALL TRANSVERSE JOINTS FOR DUCTWORK WITH STATIC PRESSURE BETWEEN 1/2 INCHES AND 2 INCHES. DUCTWORK WHICH IS DESIGNED TO OPERATE AT PRESSURES ABOVE 1/2 INCH WATER COLUMN STATIC PRESSURE SHALL BE SEALED IN ACCORDANCE WITH STANDARD RS -7. 1.5 ALL DUCT GAUGES PER SMACNA, IMC 603-4. 1.6 ALL DUCT SUPPORTS PER SMACNA, IMC 603-10. 1.7 ATTACH DIFFUSERS AND GRILLES TO T -BAR GRID PER WA STATE & LOCAL CODES. 1.8 BALANCING DAMPERS ARE TO BE INSTALLED ON ALL BRANCH DUCTS OR DIFFUSERS. INSULATION 2.1 INSULATE OR LINE DUCTWORK PER WA. STATE ENERGY AND MECHANICAL CODES. 22 INSULATE REFRIGERANT & CONDENSATE PIPING PER STATE & LOCAL ENERGY CODES: GENERAL CONTRACTOR 3.1 GENERAL CONTRACTOR TO PROVIDE AND CUT OPENINGS FOR ALL ROOFTOP, CEILING, FLOOR, AND WALL PENETRATIONS, INCLUDING WEATHERPROOF SEALING AND FIRE PROOF LINING PER IMC & IBC. 32 GENERAL CONTRACTOR TO VERIFY PENETRATION LOCATION AND DIMENSIONS WITH ERL BEFORE FRAMING OPENINGS. 3.3 GENERAL CONTRACTOR TO PROVIDE ALL DEMOLITION, PATCHING, AND PAINTING AS REQUIRED FOR MECHANICAL WORK. 3.4 GENERAL CONTRACTOR TO PROVIDE ADEQUATE STRUCTURAL SUPPORT AS REQUIRED FOR MECHANICAL WORK. 3.5 GENERAL CONTRACTOR TO PROVIDE ADEQUATE ENGINEERING AS REQUIRED FOR MECHANICAL WORK. 3.6 GENERAL CONTRACTOR TO PROVIDE SERVICE ACCESS PER CODE TO ALL MECHANICAL EQUIPMENT: 3.7 GENERAL CONTRACTOR TO LEVEL ALL FACTORY CURBS PROVIDED BY ERL PROVIDE ALL CANT STRIPS AND CURB INSULATION, AND SEAL AGAINST LEAKS. 3.8 GENERAL CONTRACTOR TO PROVIDE ALL CUTTING AND PATCHING OF T -BAR CEILING AS REQUIRED FOR HVAC INSTALLATION:, 3.9 GENERAL CONTRACTOR TO PROTECT ALL OPENINGS THROUGH FLOORS PROVIDED FOR DUCTWORK INSTALLATION IN ACCORDANCE WITH TABLE 601 OF INTERNATIONAL BUILDING CODE, WHERE REQUIRED BY SECTION 707 OF IBC. ELECTRICAL 4:1 ERL TO INSTALL ALL LOW VOLTAGE CONTROL WIRING, CONDUIT WILL BE PROVIDED BY ELECTRICAL CONTRACTOR 42 ELECTRICAL CONTRACTOR TO PROVIDE ALL ELECTRICAL CONNECTIONS, DISCONNECTS, AND STARTERS FOR MECHANICAL EQUIPMENT. 4.3 ELECTRICAL CONTRACTOR TO VERIFY EQUIPMENT SIZES, LOADS AND LOCATIONS WITH ERL MECHANICAL PLAN AND WITH FIELD CONDITIONS. 4.4 ELECTRICAL CONTRACTOR TO INTERLOCK BATHROOM EXHAUST FANS WITH LIGHT SWITCH. 4.5 ERL TOP.OV PROVIDE DAY. NIGHT SETBACK, PROGRAMMABLE TYPE T -STAT WITH CAPABILITY. OF 5°F DEADBAND. 4.6 ERL TO VERIFY FINAL LOCATION OF THERMOSTAT WITH CUSTOMER. 4.7 ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL GCFI OUTLET WITHIN 25 FT OF EACH PIECE OF MECHANICAL EQUIPMENT. PLUMBING 5.1 PLUMBING CONTRACTOR TO FURNISH AND INSTALL ALL GAS PIPING FOR MECHANICAL EQUIPMENT PER CODE. 52 PLUMBING CONTRACTOR OFFSET VENTS 10 FEET MINIMUM FROM ALL HVAC FRESH AIR INTAKES OR 2' ABOVE HIGHEST POINT OF INTAKE, IMC 401.4.1. 5:3 CONDENSATE DRAINS FROM RTU BY ERI TO DRAIN WITHIN 12" OF UNIT. CONDENSATE DRAINS FOR AIR HANDLERS BY PLUMBER. ENERGY CODE COMPLIANCE 6.1 AT A MINIMUM, ,, H FLOOR IS TO BE CONSIDERED A SEPARATE ZONE. VERIFY THERMOSTATI T.:ONTROL FOR EACH ZONE AS INDICATED ON PLANS. 6.2 OUTSIDE A'R INTAKES, EXHAUST OUTLETS, AND RELIEF OUTLETS SERVING CONDITIOfsb:D SPACES SHALL BE EQUIPPED WITH DAMPERS WHICH CLOSE AUTOMAT' :ALLY WHEN THE SYSTEM IS OFF OR UPON POWER FAILURE, PER WSEC SEC. 1412.4.1. 6.3 AIR ECONOMIZERS WHERE REQUIRED BY CODE ARE INDICATED BY THE EQUIPMENT SCHEDULE AT 100% CAPABILITY, CONTROL AND OPERATION OF THE ECONOMIZER SHALL CO('PLY WITH WSEC SEC. 1423. MECHANICAL CODE COMPLIANCE 7.1 WHERE REQUIRED PROVIDE AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTORS IN EACH SYSTEM DELIVERING HEATING OR COOLING AIR IN EXCESS OF 2000 CFM. DETECTORS SHALL BE LOCATED IN THE MAIN RETURN AIR PER IMC 606. WA2004#1 U w w z w w w r NOT PUBLISHED. ALL RIGHTS RESERVED, THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE DF ACCEPTANCE OF THESE RESTRICTIONS.' (206) 763 - 1744 co QO 0 cnWw Q 727 SOUTH KENYON EVERGRL954R2 0 4 0 NOT FOR CONSTRUCTION PROGRESS PRINTS - (n 0 W 0. HVAC COVER SHEET REVISIONS NO DATE ITEM 4/30/13 GEN, REV, DRAWING DATE: 04/10/13 DWG. BY: GN CHK. BY: JS JOB NO.: L 513196 DWG. FILE: 513196M1. SHEET: M 1 1 of 3 SHEETS SYMBOL LEGEND SYMBOL ABBV. DESCRIPTION DUCT SECTION SUPPLY ►;�� DUCT SECTION - RETURN/EXHAUST ra RECTANGULAR DUCT 7 ROUND DUCT FLEXIBLE DUCT MVD MANUAL VOLUME DAMPER BDD BDD BACKDRAFT DAMPER IMD MOTORIZED DAMPER FD FIRE DAMPER FSD FIRE/SMOKE DAMPER (120V POWER REQ.) -®-4 CEILING RADIATION DAMPER sn SD SMOKE DETECTOR 0 T THERMOSTAT Q S RECEIVED. SENSOR CITY OF TUKWI -R- - - -P R REFRIGERANT LINES MAY 0 6 2013 -G- - -' G NATURAL GAS LINES PERMIT CENTE - CEILING DIFFUSER (SUPPLY) 0 CEILING DIFFUSER (RETURN/EXHAUST) r EXHAUST FAN (CEILING MOUNTED) IMI I INLINE FAN PROPELLER FAN 1 I SIDEWALL DIFFUSER REvisioN 1,,, DUCT FITTING B4O.J. 12' 2" - DATUM UNIT. TAG �W 1 z DUCT RISER 1 U w w z w w w r NOT PUBLISHED. ALL RIGHTS RESERVED, THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE DF ACCEPTANCE OF THESE RESTRICTIONS.' (206) 763 - 1744 co QO 0 cnWw Q 727 SOUTH KENYON EVERGRL954R2 0 4 0 NOT FOR CONSTRUCTION PROGRESS PRINTS - (n 0 W 0. HVAC COVER SHEET REVISIONS NO DATE ITEM 4/30/13 GEN, REV, DRAWING DATE: 04/10/13 DWG. BY: GN CHK. BY: JS JOB NO.: L 513196 DWG. FILE: 513196M1. SHEET: M 1 1 of 3 SHEETS 11 ..11 11 11 -LI_ .. 1111 11 11 11 11 11 11 11 NOTES: 1.TO ERL'S BEST JUDGEMENT, WE CALCULATE TWELVE (12) NECESSARY PENETRATIONS THROUGH STRUCTURAL I - BEAMS IN CEILING ABOVE THE OPEN OFFICE ON THE MAIN FLOOR; - 6 PENETRATIONS THROUGH BEAM ON GRID LINE A -4 PENETRATIONS THROUGH BEAM ON GRID LINE B 2 PENETRATIONS THROUGH BEAM ON GRID LINE C 2. ALL PENETRATIONS THROUGH STRUCTURAL ZBEAMS BE 10"O IN SIZE IN ACCORDANCE WITH ERL PLANS. 3. HEATING AND AIR CONDITIONING WILL BE ACHIEVED IN RECEPTION/LOBBY AREA THROUGH THE COMBINATION OF LOW RETURN AIR GRILLES IN THE SPACE AND SPECIFIED DIFFUSERS, THE LOW RETURNS WILL PROVIDE ARDITIONAL AIR CIRCULATION. THE SPECIFIED DJEFUSERS WILL BE TITUS HIGH PERFORMANCE TMS CEILING DESIGNED TO ACCOMMODATE AREAS THAT REQUIRE A LARGER AIR DISPERSION. REST OF OFFICES DIFFUSERS ARE MCD FOR SUPPLY, 50F FOR RETURN: 14"x8" r - r - 1 12"k8" DWN 13"x/16 DWN 4300 vav�: — �. � .mow , �4 � ��' x"00 � � :1 a�1 . Iarli: alliwimp po Im%,Viromemme.--mti_VMgioi:&V.M17== iii -liI ja��IIIIIiw=Elm= NIINUIII—i®111 L___ == =A h=== 4"x14" REVIEWED FOR. CODE COMPLIANCE APPROVED MAY 10 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 06 2013 PERMIT CENTER 00 M N I M CSO CO O LL M- A 1 'V -- I 0 N 00 0 00 CZZ Q CDZ COQ 144 CO oL.L. NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. • PROGRESS PRINTS - NOT FOR CONSTRUCTION DATE: 04/10/13 ❑ APPROVED FINAL DRAWINGS DATE: ❑ CONSTRUCTION DRAWINGS DATE: ❑ AS BUILT DRAWINGS _• DATE: 0 W' 2 O Z HVAC FLOOR PLAN 4320 S 131ST PLACE TUKWI LA, WA 98124 z p (y N.czJ Cr LD Q REVISIONS NO DATE ITEM A 04/16/13 GEN. REV. A 4/30/13 GEN. REV. DRAWING DATE: 04/10/13 Lu DWG. BY: GN CHK. BY: JS JOB NO.: 513196 DWG. FILE: 513196M1 SHEET: 2 2OF 3 SHEETS NOT PUBLISHED. ALL RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF EVE- RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED, ADAPTED, DISC- LOSED OR DISTRIBUTED TO OTHERS, SOLD, PUB- LISHED OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. NOTES: j i -T II II 11 11. • II HH 11 II 11 u_ - — ^. . __LL-_ . _J_ i. 1 I I 1 L J LJ 1 I ^ 1 i y< < >1'/ vJ L ---J r—i r-1 r-1 r—i r—i 1 1 1 I I I 1-I 1 1 1 1. I I. I 11 I 1 1 .1 1 I I 1 I 1 11 .1 1 I I 1 1 I. L-J-L_J L-JL-JL_J f-'1 r-1 rl' r I 11 1 1- 1 1 1 1 I 1 11 I 1 1 1 1 1 1 1 1 1 1 I 1 1 1 1 1 L_J L_J L -J L -J L_J F===1 F===1 F===1 F== KEY NOTES: 1. HEATING AND AIR CONDITIONING WILL BE ACHIEVED IN RECEPTION/LOBBY AREA THROUGH THE COMBINATION OF LOW RETURN AIR GRILLES IN THE SPACE AND SPECIFIED DIFFUSERS, THE LOW RETURNS WILL PROVIDE ADDITIONAL AIR CIRCULATION. THE SPECIFIED DIFFUSERS WILL BE TITUS HIGH PERFORMANCE TMS CEILING DESIGNED TO ACCOMMODATE AREAS THAT REQUIRE A LARGER AIR DISPERSION. - REST OF OFFICES DIFFUSERS ARE MCD FOR SUPPLY, 50F FOR RETURN. 0 4 0 I I I I I I I L- -_J RETURN GRILLE TO BE WALL MOUNTED (VERSUS TYPICAL CEILING MOUNTED GRILLES) GRILLE TO BE LOCATED PER ERL DESIGN, HIGH ON WALL NEXT TO CEILING. FAX (206) 763 - 2389 W IJ W 1 I1 1 1 II I I it 1 1 1 I 11 I L____J L-__.-JL-_.--J UU L .J -.J L_.J LJ L -J 8" UP TO ROOF F===1 F===1 CONSTRUCTION PROGRESS PRINTS NOT FOR 0v, Z 0 z J 0 Z .. Z L O 1- W > CC 0_C‘ 0. Z 0 0 < 0 BUILT DRAWINGS III El El El -r x8"UP 1 1 1 1 1 1 1 I I I 811 1 1 10" 112 1 usiinWIIIIIMMINIMINI 115M141 LIIL% 12'8" UP G', eiRVE RTU -3 \NALL pRILLE 20"x2 1 I TiHERM. SRVE RTU -4 I I ==_1 THERM. E Zn -1 THERM. SE vi :on SiiI�.iHg1 1,. 5? a ..,,......,..._ff,„ir,,,,..„o ,............,.,,,.. Effiliramsormarsimisimmiwommom Himassist)4 1 MIN 1111 ■;1 ! MEI III VAI =MEE IMILIMEMEiliaraiffic I__Il MtttttttttMomol MENNUM amistanni 11111111111 a-4 grairerainsmommil oli r" ®®_�t���W�1�1�1111111 L )1 n aj' II •� ii ....,:__. 1___I L=== LL=_ —_� E --_J L__ -i L -_- ar."- —r I - — i®Itlavon li►glf�L�a■ I larmomm- TM mom -�Ilr �� e>•s.ir�d 400 '�A�17� ►s` .1.34■ 727 SOUTH KENYON W ce O z HVAC FLOOR PLAN NO REVISIONS DATE 04/16/13 ITEM GEN, REV, PROVIDE BYERL INSTALL BY OTHERS) REVIEWED FOR 'CODE COMPLIANCE APPROVED V A N MAY 10 2013 EVERGRL954R2 DRAWING DATE: 04/10/13 DWG. BY: GN CHK. BY: JS JOB NO.: City of Tukwila BUILDING DIVISION 513196. DWG. FILE: 513196M1 SHEET: � 13-07 �- RECEIVED CITY OF TUKWILA MAY 0 6 2013 3 PERMIT CENTER OF SHEETS _. 1 ar."- —r I - — i®Itlavon li►glf�L�a■ I larmomm- TM mom -�Ilr �� e>•s.ir�d 400 '�A�17� ►s` .1.34■ 727 SOUTH KENYON W ce O z HVAC FLOOR PLAN NO REVISIONS DATE 04/16/13 ITEM GEN, REV, PROVIDE BYERL INSTALL BY OTHERS) REVIEWED FOR 'CODE COMPLIANCE APPROVED V A N MAY 10 2013 EVERGRL954R2 DRAWING DATE: 04/10/13 DWG. BY: GN CHK. BY: JS JOB NO.: City of Tukwila BUILDING DIVISION 513196. DWG. FILE: 513196M1 SHEET: � 13-07 �- RECEIVED CITY OF TUKWILA MAY 0 6 2013 3 PERMIT CENTER OF SHEETS NOTES: 1 TO ERL'S BEST JUDGEMENT, WE CALCULATE TWELVE (12) NECESSARY PENETRATIONS THROUGH STRUCTURAL I= BEAMS IN CEILING ABOVE THE OPEN OFFICE ON THE MAIN FLOOR; 6 PENETRATIONS THROUGH BEAM ON GRID LINE A 4 PENETRATIONS THROUGH BEAM ON GRID LINE B - 2 PENETRATIONS THROUGH BEAM ON GRID LINE C 2, ALLPENETRATIONS THROUGH •STRUCTURAL'L-BEAMS: BE 10"0 IN SIZE IN ACCORDANCE WITH ERI- PLANS. • 3. HEATING AND AIR CONDITIONING WILL BE ACHIEVED IN RECEPTION/LOBBY AREA THROUGH THE COMBINATION OF, LOW RETURN AIR GRILLES IN THE SPACE AND SPECIFIED DIFFUSERS, THE. LOW RETURNS WILL PROVIDE ADDITIONAL AIR CIRCULATION. THE SPECFID DIFFUSERS WILL'BE TITUS HIGH PERFORMANCE TMS CEILING DESIGNED TO ACCOMMODATE AREAS THAT REQUIRE A. LARGER: AI R'DISRERSION. REST OF OFFICE$ D1FFUSERS ARE MCD I=OR SUPPLY, 5QF FOR RETURN( COLAE I.COMPLRo.VECIANCE. MAY 0 2. 203 wty:Of Tt;lalc ita' B iL;DING DIVISION' NOT PUBLISHED: ALL. RIGHTS. RESERVED. THE DRAWING AND SPECIF.ICATIONS, IDEAS DESIGNS `:'• AND ARRANGEMENTS REPRESENTED ..THEREBY.>•, ARE AND. SHALL REMAIN THE PROPERTY OF•EVE RGREEN REFRIGERATION INC..NO PART THEREOF SHALL. BE REPRODUCED. COPIED, ADAPTED, DISC LOSED OR. DISTRIBUTED • TO OTHER% SOLD, PUB- LISHED OR.OTHERWISE USED 'WITHOUT THE PRIOR WRITTEN CONSENT OF. AND' APPROPRIATE COMPEN- SATION TO EVERGREEN REFRIGERATION. INC. VISUAL CONTACT .WITH '.THE ABOVE DRAWINGS OR SP.ECIFIC- ATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE. OF THESE RESTRICTIONS.',..' Cr) 11 Fr4 ILO • V 'IIIMIEM111111111111111MEMISHINIM. IA / IIlimiimmi imam limmorai Iid 11111 PIVIIII � __ eiI wIIIo§ �I ,• IIMMINISMEINCM 7___ERE rA".11 12 WI NE It B ASS Mt 513196M1 'REC:EIVED.' CITY QF.:TUKWILA. APR 19.2013. PERMIT C• ENTER NOTES: 1. HEATING AND AIR CONDITIONING WILL BE ACHIEVED IN RECEPTION/LOBBY AREA THROUGH THE COMBINATION OF LOW RETURN AIR GRILLES IN THE SPACE AND SPECIFIED DIFFUSERS, THE LOW RETURNS WILL PROVIDE, ADDITIONAL AIR CIRCULATION. THE SPECIFIED DIFFUSERS WILL BE TITUS HIGH PERFORMANCE TMS CEILING DESIGNED TO ACCOMMODATE AREAS THAT REQUIRE A LARGER AIR DISPERSION. REST OF OFFICES DIFFUSERS ARE MCD FOR SUPPLY, 50F FOR RETURN. NOT PUBLISHED. All. RIGHTS RESERVED. THE DRAWING AND SPECIFICATIONS. IDEAS, DESIGNS AND ARRANGEMENTS" REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY' OF EVE RGREEN REFRIGERATION INC. NO PART THEREOF SHALL BE REPRODUCED, COPIED...ADAPTED. DISC LIMED OR DISTRIBUTED,TO OTHERS, SOLD, PUB LISHED OR OTHERWISE USED WITHOUT THE PRIOR'. WRITTEN CONSENT OF AND APPROPRIATE COMPEN •SATION TO EVERGREEN REFRIGERATION INC. VISUAL CONTACT. WITH THE ABOVE DRAWINGS OR SPECIFIC- ATIONS SHALL"CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. RETURN'GRILLE TO BE WALL MOUNTED (VERSUS#'JCAL CEILING MOUNTED. GRILLES) GRILLE TOE LOCATED PER ERL DESIGN, HIGH. ON WALL NEXT TO CEILING. INIIIIINSINIIIIMINBINFAI ININVA if f l/' Is emi_gl �;, 0v iv, H RM. i I n Agi yNALL pRILLE 20"x2 TrIEIRM. SERVE RTU -4 i o� atl� P �_ s `� �� tom.:. I attren s 1 10"x141' muna1sz®miem1® BISOWEBWARMilligInif 18"x161' UP. 12'x8" UP m tumn=min v� 0. lig°1 a �� .44\r:: .. ,� ®01® e�mn,r �� . u , ���` ®=111: ,� MT, ilA�� ®. IZA1I l l 'seri► i. BBassm weal 1 mo C 11OBe®moo)—ansies }s* in®UB?Romriiiirniaa�® • AN— A I it HSI' 11111111 _P�...�,—......1ue®■ M10111161.111111111WIIMMIIIMIHINI.1111111111111E 'BIS NOMMEMENIMENIMINEllk PR0VIDE BYERL .INSTALL BY OTHERS) DWG. FILE: