HomeMy WebLinkAboutPermit M13-077 - BOEING #14-02 - BOILER REPLACE - INSTALL BOILERS AND EXPANSION TANKSBOEING #14-01 BOILER REPLACEMENT 8811 EAST MARGINAL WY S M13-077 Parcel No.: Address: City okukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://vvvvw.TukwilaWA.gov MECHANICAL PERMIT 0007400033 8811 EAST MARGINAL WY S TUKW Project Name: BOEING #14-02 - BOILER REPLACEMENT Permit Number: M13-077 Issue Date: 06/14/2013 Permit Expires On: 12/11/2013 Owner: Name: Address: Contact Person: Name: Address: Email: Contractor: Name: Address: BOEING COMPANY THE PROPERTY TAX DEPT , PO BOX 3707 M/C 20-00 98124 CONNIE HARDIN 4600 S 134 PL , SEATTLE WA 98168 C ONNIEH @HOLADAYPARKS. C OM Phone: 206 250-4530 HOLADAY PARKS, INC. Phone: 206 248-9700 PO BOX 69208 , SEATTLE, WA 98188 Contractor License No: HOLADPI379NO Expiration Date: 09/03/2013 DESCRIPTION OF WORK: INTALL (3) BOILERS AND (1) EXPANSION TANK Value of Mechanical: 400,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Fees Collected: $4,194.56 International Mechanical Code Edition: 2009 � G(I� Permit Center Authorized Signature: i / /,(/(/(-� I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. Date: e56/7(743 The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction o the pe ' • rmance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this r•la.a�.._ Signature: Print Name: I -e g. L. Date G—/ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. J..... IAA/, A/111 6A1 z_A77 Prinfor4• f1R-1 A. -')n12 PERMIT CONDITIONS Permit No. M13-077 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-077 Printed: 06-14-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address:2g11 £c rrnajnJ ._.JP(J), SO Tenant Name: King Co Assessor's Tax No.: .7 team -53 Suite Number: Floor: New Tenant: ❑ Yes E -No Name: zoo; A Vilbe M. pail Addres 0 i 2.0.0 zig,;Yvlzq City: State Valuation of project (contractor's bid price): $ t& Describe the scope of work in detail: Use: Residential: New ❑ Commercial: New Company Name: (� ks e Address: ul J.,a S * t3�atq -' e✓<•/t.0 J City:L-k State Phone:zap z zuts,30 Fax: Lot,. vizi 740 Contr Reg No. �Le�374.06xp Date: 4//3 Tukwila Business License No.: bo•\44-s Fuel Type: Electric ❑ Gas Replacement Replacement LIQ/ Other: H.\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator - domestic Incinerator - comm/industrial Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty' 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu 41,tS►li++�/�'1(C Value of construction - in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDIN Signature: Print Name: a v V ve' Mailing Address: "1 SOD S 13 HORIAGENT: Date: 11-17...." ( 3 Day Telephone: ZSZ) ,61ifixtk Oa_ et ET Co E( State Zip 11: 1ApplicationsWorms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh City Page 2 of 2 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0007400033 Permit Number: M13-077 Address: 8811 EAST MARGINAL WY S TUKW Status: APPROVED Suite No: Applied Date: 04/24/2013 Applicant: BOEING #14-02 - BOILER REPLACEMENT Issue Date: Receipt No.: R13-01890 Payment Amount: $3,355.65 Initials: LAW Payment Date: 06/14/2013 03:42 PM User ID: 1632 Balance: $0.00 Payee: HOLADAY PARKS TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 03878G ACCOUNT ITEM LIST: Description 3,355.65 Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 3,355.65 Total: $3,355.65 Printori• nf_14 nil • • J��1LA wq City of Tukwila CvJ\ r 2 2 90a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0007400033 Permit Number: M13-077 Address: 8811 EAST MARGINAL WY S TUKW Status: PENDING Suite No: Applied Date: 04/24/2013 Applicant: BOEING #14-02 - BOILER REPLACEMENT Issue Date: Receipt No.: R13-01419 Payment Amount: $838.91 Initials: JEM Payment Date: 04/24/2013 03:53 PM User ID: 1165 Balance: $3,355.65 Payee: CONNIE HARDIN, HOLADAY PARKS FAB INC TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 09409G ACCOUNT ITEM LIST: Description 838.91 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 838.91 Total: $838.91 a oe e; nc arinro.i• nd2)d_ln1z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431 3670 Permit Inspection Request Line (206) 431-2451 AA 0, 677 Projgct: aspect TypeAit : ectl esaiif £, lAT6/I4L. Date Calle e..0 / 'Address _ :� �" Special Instructions: nL j� �-� Date Wanted:/ (`am„ I! `S_ —(3 p.m. Requesier: Phor�je ,N�o•g 5 - 14E-3 Approved per applicable codes. Corrections required prior to approval. COMMENTS: j Ql% i ,1i e -B4 nsp ctor: Date: .i+ .5 -- 13 n REINSPECTION FEE fREtfUI)&D.-Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (- 6300 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 /A t 3 -077 Project: (4 -01._ Type Inspection: / Medi, o U CO o _/- Address: & SI 1 . AA WON, AJ4 Date Called: Special Instructions: Date Wanted: -13 P.m. . Requester: Phone(a 2c, t , q 2.- 7 provepd—er applre co s. Corrections required prior to approval. COMMENTS: o V '`~ n Ins gctor: I (L Date: ,:ss______( > 6 REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. Arms"AtrAg Figured by: FILE COPY• Permit No. Structural Calculations ror BOEING THOMPSON SITE BUILDING 14-02 TUKWILA, WASHINGTON May 28, 2013 Boiler Anchorage,Design Work .OrderN�: 12877635 CORRECTION Sung U. Cho, P.E. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 1 3 2013 City of Tukwila BUILDING DIVISION 11 1 3- 07 7 Copyright (C-' 2012 Boeing. All rights reserved. RECEIVED CITY OF TUKWILA JUN 0.6 2013 PERMIT CENTER Air47.EZAW Structural Calculations For BOEING THOMPSON SITE BUILDING 14-02 TUKWILA, WASHINGTON May 28, 2013 Boiler Anchorage Design Work Order No: 12877635 Figured by: Sung U. Cho, P.E. Copyright © 2012 Boeing. All rights reserved. TABLE OF CONTENTS SECTION PAGE Scope of Work 2 Seismic Load Design 3 Anchor Bolt Design 6 Appendix 13 Copyright © 2012 Boeing. All rights reserved. Page 1 ASPIZEZAVAF Project: Building - Job # By: S. Cho Date: Subject: Scope of Work Page: Structural Scope of Work Design of seismic anchor bolts for the boilers and a expansion tank. See mechanical drawings for overall layout plan. By inspection, the expansion tank has lower lateral load condition and not included in the calculation. Design Criteria 1. Dead Loads: • Weight of Boiler = 7,600 lbs • Weight of Expansion Tank = 4,800 lbs 2. Seismic Loads: • See seismic loads calculation in this report. Referenced Codes • IBC 2009; International Building Code, 2009 • ASCE 7-05; Minimum Design of Loads for Building and Other Structure, 2005 edition • ACI 318-08; Building Code Requirements for Structural Concrete and Commentary, 2008 • FEMA 412; Installing Seismic Restraints for Mechanical Equipment Page 2 gLerate-ArAedw Project: Building - Job # By: S. Cho Date: Subject: Lateral Load Calculation Page: The Boeing Company 8811 E Marginal Way S Thompson Site Tukwilla, WA 98108 Conterminous 48 States 2009 International Building Code Latitude = 47.523581 Longitude = -122.30354199999998 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1.530 (Ss, Site Class B) 1.0 0.528(S1, Site Class B) Conterminous 48 States 2009 International Building Code Latitude = 47.523581 Longitude = -122.30354199999998 Spectral Response Accelerations SMs and SM1 SMs = Fa x Ss and SM1 = Fv x S1 Site ClassD- Fa = 1.0,Fv =1.5 Period Sa (sec) (g) 0.2 1.530 (SMs, Site Class D) 1.0 0.791 (SM1, Site Class D) Conterminous 48 States 2009 International Building Code Latitude = 47.523581 Longitude = -122.30354199999998 Design Spectral Response Accelerations SDs and SD1 SDs = 2/3 x SMs and SD1 = 2/3 x SM1 Site Class D- Fa=1.0,Fv=1.5 Period Sa (sec) (g) 0.2 1.020 (SDs, Site Class D) 1.0 0.528 (SD1, Site Class D) Per USGS Seismic Data SS = 1.530 g S1 = 0.528 g SDS SD1 = SDC = 1.020 0.528 D Page 3 Project: Building - Job # By: S. Cho Date: Subject: Lateral Load Calculation Page: IBC 2009 & ASCE 7-05 Seismic Loading Calculate Seismic Design Base Shear Structure Height, hh, (ft) Sips = 2/3 SMS SD1 = 2/3 SM1 Occupancy Category= Standard -Occupancy Buildings Seismic Design Category per SDs Occupancy Importance Factor, Response Modification Factor, Building Period Coefficient, Ci T = Cl x (hh)314 TL = long -period transaction Cs = Sps/(R/IE) But need not exceed: Cs = SD1/[T(R/IE)] But not less than: Cs = 0.44SpsIE ;(not less than 0.01) Cs = 0.5S1/(R/IE) (if S1 > or = 0.6g) tE R 15 1.020 0.528 II D 1 3 0.02 0.152 6 0.340 (per USGS) (per USGS) (ASCE 7, Table 11.5.1) (ASCE 7, Table 12.2-1) (ASCE 7, Table 12.8-2) (ASCE 7, Eq 12.8-7) (ASCE 7, Fig 22-15) (ASCE 7, Eq 12.8-2) 1.155 (ASCE 7, Eq 12.8-3) = 0.045 (ASCE 7, Eq 12.8-5) = N/A (ASCE 7, Eq 12.8-6) Seismic Base Shear, Vs = CsW, (kips) _ 0.340 x Weight Calculate Seismic Force for Components (Per ASCE7-05 Chapter 13) Component amplification factor, ap Component Importance factor, Ip Component operating weight, Wp Component response modification factor, Rp Height of attachment / Mean roof height, z/h Seismic Design Force, Fp = (0.4ar,SngWp) (1+2xz/h) Rp/Ip Max. seismic design force, Fpmax = Min. seismic design force, Fpmin = 1.6SDSIpWP 0.3SDSIpWP 1 (ASCE 7, Table 13.5.1 & 13.6.1) 1 (ASCE 7, Section 13.3) Wp (Ib) 1.5 (ASCE 7, Table 13.5.1 & 13.6.1) 0 (z/h need not exceed 1.0) 0.272 Wp 1.632 Wp 0.306 Wp (Eq. 13.3-1) (Eq. 13.3-2) (Eq. 13.3-3) Seismic Design Force, Fp = 0.272 Wp Used for Anchor Design Page 4 gLAsPezezmo. Project: Building - Job # By: S. Cho Date: 05/28/13 Subject: Lateral Load Calculation Page: Seismic Load Calculation for Components and System (Reference: IBC 2006, Section 1609 & ASCE 7-05, Chapter 6.0) Load Combination (ASCE 7-05,Section 2.4) 1 DL 5a DL+WL 5b DL+0.7EL 6a DL+0.75WL 6b DL+0.53EL 7 0.6DL+WL 8 0.6DL+0.7EL Design Parameter DL = Equipment Weight (WP) LL = N/A WL = N/A EL, = pQE + 0.2SDSD EL2 = pQE - 0.2SDSD p = 1.0 QE, Fp = 0.272 Wp SDs = 1.020 D = DL Lateral Toad Hot Water Boiler Hot Water Boiler (see cut sheet) Equipment Weight (Wp) = Fp=pQE= 0.2SDsD = h= w= [ASCE 7-05, Eq.12.4-1] [ASCE 7-05, Eq.12.4-2] 7600 lbs 2067.2 lbs 1550.4 lbs 85.0 in 48.0 in (conservatively use full height) CI in --MGM' PORI 4 u Page 5 0.1.441S, atE/Nar Project: Building - WO # By: S. Cho Date: 05/28/13 Subject: Lateral Load Calculation Page: Connection Desiqn Russells Test Chamber 0.7p QE Vu = Tu = Tu = 4 bolts h x0.7p QE+w/2x[0.7(0.2SDsD)-DL] w x 2 bolts h x0.7p QE+w/2x[0.7(0.2SDsD)-0.6DL] w x 2 bolts 361.76 lbs _ -347.4 Ibs = 412.6 lbs (GOVERN) Use min. 3/8",:k Hilti KB -TZ with 2-3/4" min embed or approved equal. (Tallow = 1,273 lbs, Vanow = 999 lbs) DD V T/C T/C Page 6 www.hilti.us MULTI Profis Anchor 2.3.6 Company: Boeing Page: Specifier: Sung Cho Project: Address: 9725 E. Marginal Way South, Tukwila, WA 98108 Sub -Project 1 Pos. No.: Phone I Fax: 425-237-5164 1 Date: E -Mail: sung.u.cho@boieng.com 1 14-02 Boiler Anchor 5/28/2013 Specifiers comments: 1 Input data Anchor type and diameter: Kwik Bolt TZ - CS 3/8 (2) Effective embedment depth: hef = 2.000 in., hnom = 2.313 In. Material: Carbon Steel Evaluation Service Report: ESR -1917 Issued I Valid: 11/1/2012 1 5/1/2013 Proof: design method ACI 318 / AC193 Stand-off installation: eb = 0.000 in. (no stand-off); t = 0.250 in. Anchor plate: IX x I„ x t = 3.000 in. x 3.000 in. x 0.250 in.; (Recommended plate thickness: not calculated) Profile: Rectangular plates and bars (AISC); (L x W x T) = 0.250 in. x 0.188 in. x 0.000 in. Base material: cracked concrete, 3000, fb' = 3000 psi; h = 13.000 in. Reinforcement: tension: condition B, shear: condition B; no supplemental splitting reinforcement present edge reinforcement: none or < No. 4 bar Seismic loads (cat. C, D, E, or F) yes (D.3.3.4) Geometry [in.] & Loading [Ib, in.Ib] Z Input data and results must be checked for agreement with the existing conditions and for plans! PROFIS Anchor (c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Hi flag ?chaan www.hilti.us 1■■11`T1 Profis Anchor 2.3.6 Company: Boeing Page: Specifier: Sung Cho Project: Address: 9725 E. Marginal Way South, Tukwila, WA 98108 Sub -Project I Pos. No.: Phone I Fax: 425-237-5164 I Date: E -Mail: sung.u.cho@boieng.com 2 14-02 Boiler Anchor 5/28/2013 2 Load case/Resulting anchor forces Load case: Design loads Anchor reactions [Ib] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 403 360 360 0 max. concrete compressive strain: - [] max. concrete compressive stress: - [psi] resulting tension force in (x/y)=(0.000/0.000): 403 [Ib] resulting compression force in (x/y)=(0.000/0.000): 0 [Ib] 3 Tension Toad Load Nua [Ib] Capacity 4N„ [Ib] Utilization YN = N„./4,N„ Steel Strength* 403 4875 9 OK Pullout Strength* 403 1212 34 not recommended" Concrete Breakout Strength" 403 1284 32 not recommended" * anchor having the highest loading '"anchor group (anchors in tension) A When D.3.3.4 is selected for seismic design, the design steel strength must be the governing design strength having the highest utilization. Status 3.1 Steel Strength Nsa = ESR value refer to ICC -ES ESR -1917 (I) Nsteel Z Nua ACI 318-08 Eq. (D-1) Variables n Ase.N [in.z] fats [psi] 1 0.05 125000 Calculations Nsa [Ib] 6500 Results Nsa [Ib] steel Nsa [Ib] Nua [Ib] 6500 0.750 4875 403 Input data and results must be checked for agreement with the existing conditions and for plauypilityl PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of F{ijtali'i, gchaan www.hilti.us PI I UT I Profis Anchor 2.3.6 Company: Specifier: Address: Phone I Fax: E -Mail: Boeing Sung Cho 9725 E. Marginal Way South, Tukwila, WA 98108 425-237-5164 sung.u.cho@boieng.com Page: Project: Sub -Project 1 Pos. No.: Date: 3 14-02 Boiler Anchor 5/28/2013 3.2 Pullout Strength fC Npn,f = Np,zsoo 2500 Npn,fo Z Nua Variables ff [psi] 3000 refer to ICC -ES ESR -1917 ACI 318-08 Eq. (D-1) Np,2500 [Ib] Calculations •Nir 2500 1.095 Results Nin f. [Ib] 2487 2270 concrete 0.650 seismic 0.750 3.3 Concrete Breakout Strength ANC Nth- GANc0/ Wed.N Vc,N Vfcp,N Nb 4) Nei >_ Nua ANC see ACI 318-08, Part D.5.2.1, Fig. RD.5.2.1(b) ANce = 9 hat 1 41ec,N= 1+2eN) s1.0 3hef/ 1ped,N = 0.7 + 0.3 (1.5hef/ ca,min c 1.0 l� 41cp,N = MAX( a,min 1-5hetl c 1.0 Cac Cac / Nb = kc f hef5 Variables hef [in.] 2.000 ec1,N [in.] ec2,N [in.] 4 Nnn,f, [Ib] 1212 ACI 318-08 Eq. (D-4) ACI 318-08 Eq. (D-1) ACI 318-08 Eq. (D-6) ACI 318-08 Eq. (D-9) ACI 318-08 Eq. (D-11) ACI 318-08 Eq. (D-13) ACI 318-08 Eq. (D-7) Cac [In.] 4.000 0.000 kC 0.000 Calculations ANC [in.2] 36.00 Results NCb [Ib] 2634 17 ANco [in.2] 36.00 +concrete 0.650 1 Went ,N 1.000 +seismic 0.750 Ca,min [in.] fc [psi] 3000 41ec2,N 1.000 Ncb [Ib] 1284 Nua [Ib] 403 41c,N 1.000 41ed,N 1.000 Nua [Ib] 403 Ww,N 1.000 Nb [Ib] 2634 Input data and results must be checked for agreement with the existing conditions and for plausilgl PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of MAW ®chaan www.hilti.us Profis Anchor 2.3.6 Company: Specifier: Address: Phone I Fax: E -Mail: Boeing Page: 4 Sung Cho Project: 14-02 Boiler Anchor 9725 E. Marginal Way South, Tukwila, WA 98108 Sub -Project I Pos. No.: 425-237-5164 1 , Date: 5/28/2013 sung.u.cho@boieng.com 4 Shear Toad Load Vua [Ib] Capacity 0Vn [Ib] Utilization pv = V../4)V. Status Steel Strength* 360 1466 25 OK Steel failure (with lever arm)* N/A N/A N/A N/A Pryout Strength** 360 1383 27 not recommended" Concrete edge failure in direction ** N/A N/A N/A N/A ' anchor having the highest loading **anchor group (relevant anchors) A When D.3.3.4 is selected for seismic design, the design steel strength must be the governing design strength having the highest utilization. 4.1 Steel Strength Vseis = ESR value Vsteel 2 Vua refer to ICC -ES ESR -1917 ACI 318-08 Eq. (D-2) Variables n Ase,v [in•2] feta [psi] 1 0.05 125000 Calculations Vsa [Ib] 2255 Results Vsa [Ib] 4steel Vsa [Ib] Vua [Ib] 2255 0.650 1466 360 4.2 Pryout Strengt1/h AN VV,– k,[(Kt-4 Wed,N lllc,N lllcp,N Nb11 Vcp z Vua ANc see ACI 318-08, Part D.5.2.1, Fig. RD.5.2.1(b) ANcO = 9 hef tllec,N = 1 + 2 eN 5 1.0 3 her WedN=0.7+0.3 (1.5clminher) 51.0 t11cp.N = MAX (ca=min 1.5het1 1.0 Cac Cac J Nb =kc7 h15 ACI 318-08 Eq. (D-30) ACI 318-08 Eq. (D-2) ACI 318-08 Eq. (D-6) ACI 318-08 Eq. (D-9) ACI 318-08 Eq. (D-11) ACI 318-08 Eq. (D-13) ACI 318-08 Eq. (D-7) Variables kcp hef [in.] ec1,N [in.] ee2,N [in.] Ca,m!n [in.] 1 2.000 0.000 0.000 'I/c.N Cac [in.] kc � fc [psi] 1.000 4.000 17 1 3000 Calculations ANc [in.2] ANcp [in.2] Wecl,N 111ec2,N 36.00 36.00 1.000 1.000 1.000 1.000 Results Vcp [Ib] concrete Cseismic V, [Ib] Vua [Ib] 2634 0.700 0.750 1383 360 Nb [lb] 2634 Input data and results must be checked for agreement with the existing conditions and for pian ibil ! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Ali, haan www.hilti.us Profis Anchor 2.3.6 Company: Boeing Page: Specifier: Sung Cho Project: Address: 9725 E. Marginal Way South, Tukwila, WA 98108 Sub -Project I Pos. No.: Phone I Fax: 425-237-5164 1 Date: E -Mail: sung.u.cho@boieng.com 5 14-02 Boiler Anchor 5/28/2013 5 Combined tension and shear Toads N 0.332 [3NV = (iN 4.6 <= (3v Utilization [3N,v [%] Status 0.260 5/3 27 OK .6 Warnings • To avoid failure of the anchor plate the required thickness can be calculated in PROFIS Anchor. Load re -distributions on the anchors due to elastic deformations of the anchor plate are not considered. The anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the loading! • Condition A applies when supplementary reinforcement is used. The c factor is increased for non -steel Design Strengths except Pullout Strength and Pryout strength. Condition B applies when supplementary reinforcement is not used and for Pullout Strength and Pryout Strength. Refer to your local standard. Refer to the manufacturer's product literature for cleaning and installation instructions. Checking the transfer of loads into the base material and the shear resistance are required in accordance with ACI318 or the relevant standard! An anchor design approach for structures assigned to Seismic Design Category C, D, E or F is given in ACI 318-08 Appendix D, Part D.3.3.4 that requires the goveming design strength of an anchor or group of anchors be limited by ductile steel failure. If this is NOT the case, Part D.3.3.5 requires that the attachment that the anchor is connecting to the structure shall be designed so that the attachment will undergo ductile yielding at a load level corresponding to anchor forces no greater than the controlling design strength. In lieu of D.3.3.4 and D.3.3.5, the minimum design strength of the anchors shall be multiplied by a reduction factor per D.3.3.6. • An alternative anchor design approach to ACI 318-08, Part D.3.3 is given in IBC 2009, Section 1908.1.9. This approach contains "Exceptions" that may be applied in lieu of D.3.3 for applications involving "non-structural components" as defined in ASCE 7, Section 13.4.2. An alternative anchor design approach to ACI 318-08, Part D.3.3 is given in IBC 2009, Section 1908.1.9. This approach contains "Exceptions" that may be applied in lieu of D.3.3 for applications involving "wall out -of -plane forces" as defined in ASCE 7, Equation 12.11-1 or Equation 12.14-10. It is the responsibility of the user when inputting values for brittle reduction factors (y nonductile) different than those noted in ACI 318-08, Part D.3.3.6 to determine if they are consistent with the design provisions of ACI 318-08, ASCE 7 and the governing building code. Selection of ynonducrile = 1.0 as a means of satisfying ACI 318-08, Part D.3.3.5 assumes the user has designed the attachment that the anchor is connecting to undergo ductile yielding ata force level <= the design strengths calculated per ACI 318-08, Part D.3.3.3. Fastening does not meet the design criteria! Input data and results must be checked for agreement with the existing conditions and for pla ibili ! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of Fii�W,Igthaan www.hilti.us Profis Anchor 2.3.6 Company: Specifier: Address: Phone I Fax: E -Mail: Boeing Sung Cho 9725 E. Marginal Way South, Tukwila, WA 98108 425-237-5164 1 sung.u.cho@boieng.com Page: Project: Sub -Project I Pos. No.: Date: 6 14-02 Boiler Anchor 5/28/2013 7 Installation data Anchor plate, steel: - Profile: Rectangular plates and bars (AISC); 0.250 x 0.188 x 0.000 Hole diameter in the fixture: df = 0.438 in. Plate thickness (input): 0.250 in. Recommended plate thickness: not calculated Anchor type and diameter: Kwik Bolt TZ - CS, 3/8 (2) in. Installation torque: 300.000 in.lb Hole diameter in the base material: 0.375 in. Hole depth in the base material: 2.625 in. Minimum thickness of the base material: 5.000 in. Cleaning: Manual cleaning of the drilled hole according to instructions for use is required. y Coordinates Anchor in. Anchor x y 1 0.000 0.000 c -x c+x c -y c+y x Input data and results must be checked for agreement with the existing conditions and for plaiikbilityl PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of iiia ,Vehaan 0 0 1.500 1 1.500 0 0 in 1.500 1.500 Coordinates Anchor in. Anchor x y 1 0.000 0.000 c -x c+x c -y c+y x Input data and results must be checked for agreement with the existing conditions and for plaiikbilityl PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of iiia ,Vehaan www.hilti.us Profis Anchor 2.3.6 Company: Boeing Page: Specifier: Sung Cho Project: Address: 9725 E. Marginal Way South, Tukwila, WA 98108 Sub -Project I Pos. No.: Phone I Fax: 425-237-5164 1 Date: E -Mail: sung.u.cho@boieng.com 7 14-02 Boiler Anchor 5/28/2013 8 Remarks; Your Cooperation Duties Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use -specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for pla ibili ! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL -9494 Schaan Hilti is a registered Trademark of HiM , haan Copyright © 2012 Boeing. All rights reserved. Appendix Page 14 Cho, Sung U From: Tom Anderson <Toma@fsi-engineers.com> Sent: Friday, May 24, 2013 9:27 AM To: Anderberg, Nari L; Cho, Sung U Cc: Brian Johnson; Fisher, Steve W Subject: RE: 14-02 Tukwila permit review comments Attachments: CB -7237 Flextube Boiler 2012.pdf; Bell & Gossett WTA-454 Expansion Tank.pdf; UH PRC001-EN_08012007 - Unit Heater.pdf Sung, permit review can drag out sometimes, so let's push to get this turned around. Let's shoot for Wednesday to get this updated. Attached are cut sheets for the project equipment: • boiler cut sheet. See Page 5 for dimensions and weight. • Expansion tank cut sheet. Wet (operating) weight will be • Unit heater cut sheet. Model A-25: operating weight will be 4800Ibs max. Let me know if you need anything else. Tom 60Ibs max. From: Anderberg, Nari L [mailto: nari.l.anderberg(aboeing.com] Sent: Friday, May 24, 2013 8:52 AM To: Tom Anderson; Cho, Sung U Cc: Brian Johnson; Fisher, Steve W Subject: RE: 14-02 Tukwila permit review comments Hi Tom and Sung, Holaday Parks is slated to start their demo on July 8th and install the new boilers by July 22"d. I am unclear on the turn- around time for the permit, however, if we are able to meet those dates, I do not have a problem. Thank you. NARI ANDERBERG c:425.512.31$5 I mc:46-86 From: Tom Anderson [mailto:Toma@fsi-engineers.com] Sent: Friday, May 24, 2013 8:50 AM To: Cho, Sung U; Anderberg, Nari L Cc: Brian Johnson; Fisher, Steve W Subject: RE: 14-02 Tukwila permit review comments Nari, do you have a hard target date for returning the revised permit drawings? We have addressed the other permit comments, so this is the final item to complete. Tom From: Cho, Sung U [mailto: Sung.U.Cho@boeing.com] Sent: Friday, May 24, 2013 8:45 AM 1 Page 15 • ®IMENSIONS & WEIGHTS STEAM F c REAR VIEW LEFT SIDE FRONT VIEW Model'No. 150 200 .250',. 300 _ ., 350 400. _'.450.' 500. .550 600 700 800 900 1000 ' 1100 1200 A. Length of Base 68 68 68 74 74 95 95 95 95 95 116 116 116 140 140 140 B. Boiler Height 86 86 86 90 90 95 95 95 95 95 109 109 109 109 109 109 C. Boiler Width 42 42 42 42 46 46 48 48 48 48 54 54 54 54 54 54 D. Center of FG Outlet to Read of Jacket 12 12 12 12 12 15 15 15 15 15 16 16 16 16 16 16 E. Tube Removal Clearance 28 28 28 32 32 34 34 34 34 34 40 40 40 40 40 40 F. Steam Nozzle 15 psig 4 flg 4 flg 4 flg 6 flg 6 flg 6 flg 6 flg 6 flg 6 flg 6 fig 8 fig 8 flg 8 fig 10 fig 10 flg 10 flg F. Steam Nozzle 150 psig 2 mpt 2 mpt 2 mpt 2.5 mpt 2.5 mpt 3 flg 3 flg 3 flg 3 flg 3 fig 4 flg 4 flg 4 flg 6 fig 6 fig 6 flg G Vessel Length 96 96 96 104 104 127 127 127 127 127 150 150 150 183 183 183 H. Flue Gas Outlet ID 10 10 10 12 12 16 16 16 16 16 18 18 18 24 24 24 I. Flue Gas Outlet Flange OD 15 15 15 17 17 21 21 21 21 21 23 23 23 29 29 29 J. Burner Clearance 12 12 12 10 10 12 12 12 12 18 18 18 18 22 22 23 K. Height of Steam Nozzle 87 87 87 91 91 95 95 95 95 95 109 109 109 109 109 109 L. Steam Nozzle Location 34 34 34 37 37 47 47 47 47 47 58 58 58 58 58 58 M. Total Length 108 108 108 114 114 139 139 139 139 145 168 168. 168 205 205 206 Shipping Weight (lbs) 5,700 5,700 5,700 6,200 6,200 7,900 7,900 7,900 7,900 7,900 10,200 10,200 10,200 12,000 12,000 12,000 Operating Weight (lbs) 6,600 6,600 6,600 7,200 7,200 9,200 9,200 9,200 9,200 9,200 12,500 12,500 12,500 14,100 14,100 14,100 DIMENSIONS & WEIGHTS HOT WATER REAR VIEW LEFT SIDE FRONT VIEW Model No. 150 200:. 150 300 350 "400 ` 450 500 550 600 700 800 900 1000 1100 1200 A. Length of Base 68 68 68 74 74 95 95 .. 95 95 95 116 116 116 140 140 140 B. Boiler Height 76 76 76 80 80 85 85 85 85 85 94 94 94 94 94 94 C. Height of Flue Gas Outlet 78 78 78 82 82 87 87 87 87 87 96 96 96 96 96 96 D. Boiler Width 42 42 42 46 46 48 48 48 48 48 54 54 54 54 54 54 E. Center of FG Outlet to Rear of Jacket 14 14 14 12 12 16 16 16 16 16 18 18 18 18 18 18 F. Tube Removal Clearance 28 28 28 32 32 34 34 34 34 . 34 40 . 40 40 40 40 40 G. Inlet/Outlet Flange & Nozzle (NPS) 3 flg 3 flg. 3 flg 4 flg 4 flg 6 flg 6 flg 6 fig 6 flg 6 flg 6 flg 6 flg 6 flg 8 flg 8 flg 8 flg H. Flue Gas Outlet ID 10 10 10 12 12 16 16 16 16 16 18 18 18 24 24 24 1. Vessel Length 98 98 98 102 102 127 127 127 127 127 147 147 147 175 175 175 J. Flue Gas Outlet Flange OD 15 15 15 17 17 21 21 21 21 21 23 23 23 29 29 29 K. Burner Clearance 16 16 16 18 18 20 20 20 20 26 27 27 27 27 27 31 L. Total Length 114 114 114 120 120 147 147 147 147 153 174 174 174 205 205 206 Shipping Weight (lbs) 3,900 3,900 3,900 5,000 5,000 6,100 6,100 6,100 6,100 6,100 8,500 8,500 8,500 10,000 10,000 10,000 Operating Weight (lbs) 4,700 4,700 4,700 5,900 5,900 7,600 7,600 7,600 7,600 7,600 10,500 10,500 10,500 12,300 12,300 12,300 Dimensions and specifications are subject to change without notice. Dimensions are for layout purposes only and not for construction. Measurements are in inches. Page 16 "WTA" Well Water Tanks (ASME Construction) DESCRIPTION The Series WTA expansion tank is an ASME constructed precharged vessel. The WTA tanks will help protect the pump and pressure switches against short cycling. The well tank delivers adequate water under pressure between pump cycles to meet the required demand. It will provide economical system operation by minimizing pump starts, extending the life of the pump motor, and saving energy. The WTA tank will also assist the pump in meeting peak demand. Dimensions: Gallons (Ltrs.), Inches (mm), Weights: LBS. (KG) WTA-401 THROUGH WTA-405 DIAPHRAGM TANKS Maximum Working Pressure 125 PSI (862kPa) Maximum Operating Temperature 200 F (93 C) Materials: Polypropylene Liner, Butyl Diaphragm, Steel Shell, Malleable Iron System Connection Factory Precharge 30 PSI (207kPa) WTA-447 THROUGH WTA-457 BLADDER TANKS Maximum Working Pressure 125 PSI (862kPa) Maximum Operating Temperature 240 F (115 C) Materials: Butyl Replaceable Bladder, Steel Shell, Malleable Iron System Connection Factory Precharge 25 PSI (172kPa) All tanks designed and constructed per ASME Section VIII Division 1. MODEL NUMBER PART NUMBER TANK VOLUME ACCEPTANCE FACTOR A HEIGHT B DIAMETER C D E SYSTEM CONNECTION APPROX. SHPG. WT. WTA-401 1 BN 151 LF 18 (68) 0.65 311/4(794) 161/4(413) 47/8(124) 11/2 (38) 123/4(324) 1 95 (43) WTA-402 1 BN152LF 25 (95) 0.45 393/4(1010) 161/4 (413) 47/8(124) 11/2(38) 123/4(324) 1 112 (51) WTA-403 1 BN153LF 34 (129) 0.33 491/4(1251) 161/4(413) 47/8(124) 11/2(38) 123/4(324) 1 123 (56) WTA-404 1BN154LF 68 (258) 0.50 471/4(1200) 24 (610) 61/4(159) 15/8(41) 16 (406) 11/4 210 (95) WTA-405 1 BN 155LF 90 (341) 0.39 591/4 (1505) 24 (610) 61/4(159) 15/8(41) 16 (406) 11/4 280 (127) WTA-447 1 BN156LF 53 (200) 0.65 451/4 (1150) 24 (610) 2 (51) 33/4(95) 19 (483) 2 263 (120) WTA-448 1BN157LF 80 (300) 0.65 591/8(1502) 24 (610) 2 (51) 33/4(95) 19 (483) 2 308 (140) WTA-449 1 BN158LF 106 (400) 0.65 731/8(1857) 24 (610) 2 (51) 33/4(95) 19 (483) 2 352 (160) WTA-450 1 BN 159LF 132 (500) 0.65 865/8(2200) 24 (610) 2 (51) 33/4(95) 19 (483) 2 392 (178) WTA-451 1 BN 160LF 158 (600) 0.65 731/4(1867) 30 (762) 31/2(89) 51/2(140) 24 (610) 2 513 (233) WTA-452 1 BN 161 LF 211 (800) 0.65 91 (2312) 30 (762) 31/2(89) 51/2(140) 24 (610) 2 760 (345) WTA-453 1BN162LF 264 (1000) 0.65 86 (2184) 36 (914) 41/2(102) 7 (178) 30 (762) 3 810 (367) WTA-454 1 BN163LF 317 (1200) 0.65 98 (2489) 36 (914) 41/2(102) 7 (178) 30 (762) 3 914 (415) WTA-455 1 BN164LF 370 (1400) 0.65 1103/8(2804) 36 (914) 41/2(102) 7 (178) 30 (762) 3 1018 (462) WTA-456 1BN165LF 422 (1600) 0.65 817/8(2080) 48 (1220) 71/2(191) 71/8(181) 42 (1067) 3 1655 (750) WTA-457 1 BN166LF 528 (2000) 0.65 971/4 (2470) 48 (1220) 71/2(191) 71/8(181) 42 (1067) 3 1925 (873) Dimensions subject to change. Not to be used for construction purposes. CHARGING VALVE F i B --I E WTA-401 THROUGH WTA-405 xylem Let's t s Solve Water CHARGING VALVE E --I WTA-447 THROUGH WTA-457 Xylem Inc. 8200 N. Austin Avenue Morton Grove, Illinois 60053 Phone: (847) 966-3700 Fax: (847) 965-8379 www.xyleminc.com/brands/bellgossett Bell & Gossett is a trademark of Xylem Ir agent}af its subsidiaries. ©2011 Xylem Inc. A -348A August 2010 • Dimensional Data Table 29. Louver Cone Diffuser Roughing in Dimensions Unit Size A B C D No. of Louvers 42 16 1/2 14 1/4 6 1/2 2 5/8 8 64 & 80 20 17 8 3 1/8 8 102 & 122 24 1/4 21 9 3/4 3 15/16 8 146, 166 & 202 28 3/8 24 3/4 11 1/2 4 5/8 8 252, 280, 336, & 384 35 1/2 31 1/2 13 3/4 4 12 500, 600 & 720 41 1/2 37 1/4 17 4 3/4 12 Dimensional Data: S Model 14 (21-/6 7AASFOR 6USPEN(}INri UNIT •• i w 1 �\ (l4AVt,rNG) 12' F..-.. (51mm) �i IH IIlllr Ill�iIdilill (IMll1111 IHIIflI Iamilmnimmomi IIc ILII IQI : lGI 911h h, i IIll J! IIHIIltliI J,_ @1I IIII�1l •Va eU rusniS --. (.500 O.D.) Figure 17. Serpentine Type Models A08, A18, A25, A36 Note: Motors are totally enclosed, thermally protected, sleeve bearing, with 4" (w) x 2" (h) conduit connection boxes. Nutserts are attached to enclosure for balanced hanging. Table 30. Serpentine Models MODEL H W A B NO. OF NOM. FAN APPROX. C LOUVERS DIAM. SHIP WT. A08 16 18 16 7/32 11 1/4 4 1/4 5 9 22 A18 16 18 16 7/32 11 1/4 4 1/4 5 10 24 A25 16 18 16 7/32 11 1/4 4 1/4 5 10 25 A36 18 1/2 20 1/2 18 23/32 13 3/4 5 1/8 6 12 31 34 Page 18 UH-PRC001-EN FSI consulting engineers Job# 12061 Job Name 14-02 Boiler Replacement Subject Louver Free area Calc Date By BAJ Chkd. Sheet 1 of Louver Size Calculation Code requirements for supply combustion air to spaces with Gas appliances: The 2012 IFGC Section 304.6.1 require two permanent openings, "one commencing within 12 Inches of the top and one commencing with in 12 Inches of the bottom of the enclosure, shall be provided. the openings shall communicate directly or by ducts, with the out doors or spaces that freely communicate with the outdoors... Where communicating with the outdoors, or where communicating with the outdoors through vertical ducts, each opening shall have a minimum free area of 1 square inch per 4,000 BTUH of total input rating of all appliances in the enclosure." Previous BTU Input This project is removing the two existing 20 MMBTU boilers and in their place installing three 5 MMBTU boilers, totaling 15 MMBTU. There is an existing diesel emergency generator in the space as well. Louver Size Required for Boilers In order to meet the requirements of the IFGC, the boilers that will be installed will require louvers that are 3750 Inch^2 or 26 FtA2. The way this is calculated is, 15,000,000 BTUH * (1 InchA2 / 4,000 BTUH) = 3,750 Inch ^2 Emergency Generator Combustion Air The emergency generator has a Detroit turbo diesel 12.1 Liter 8V-92TA 568 HP at 1,800 RPM 1 The generators 12.1 Liter engine = 740 Cubic Inches. Using Hapco Manufacturing CO's exhaust flow chart for a diesel engine with 760 Cu In and 1,800 RPM it was determined that the exhaust flow would be 770 CFM. Applying the multiplication factor of 1.40 for a turbo diesel yields 770 CFM * 1.40 = 1078 CFM. Using Donaldson's engine exhaust flow rate formula the Intake CFM requirements can be obtained: ((Exhaust Temp ("F)+ 460)/540) * CFM Intake = Exhaust Flow. The exhaust flow calculated above with Hapco info and the Donaldson's exhaust information provides standard exhaust temperature for a turbo diesel of 900 F. Rearranging Donaldson's formula yields the following: CFM Intake = Exhaust Flow / ((Exhaust Temp ('F)+ 460)/540). Applying the known values CFM Intake = 1078 CFM / ((900 + 460) / 540) = 428 CFM. Applying a static pressure drop through louvers of 0.1 Inches of Water yields that a 500 CFM flow will require a cross sectional area of 227 Inch^2 =1.58 Ft^2. Applying a safety factor of 15% yields 1.57 Ft^2 *1.15 = 1.82 Ft^2. Rounding up provides 1.9 Ft^2. Total Louver Free Area Required The total area required for outside combustion air louvers is 26 FtA2 + 1.9 Ft^2 = 27.9 Ft^2. According to the IFGC this requirement is for a louver 12" from the top and a louver 12" from the bottom of the space. So the total building louver free area required is 27.9 Ft^2 x 2 = 55 8Ft^2. 1_ 1- -1- -. _ I Existing Louver Free Area There are 6 existing Louvers measuring 144" x 10" with a free area of 50% One Louver has 1,440 InchA2 or 5 Ft^2 free area. Combining the area of the louvers gives us 4,320 InchA2 or 30 FtA2. The existing louvers will be used as the 12" from the ceiling combustion air requirement in the IFGC. This will be accomplished by providing ducts from the existing louvers top area and extending the ducts up to with in 12" of the ceiling. New Louvers Free Area There are three new Louvers being installed. Two in the double doors that each measure 30" x 54" at 60% free area = 1,944 total InchA2 or 13.6 total Ft^2. A third louver in a new wall opening will be 48" x 90" with a free area of 15.84 Ft^2. Combined area is 13.6 Ft^2 + 15.8 Ft^2 = 29.4 Ft^2. The new Louvers will be used as the 12" from the floor combustion air requirement in the IFGC. Total Building Combustion Air Free Area The Total Building outside combustion air free area is 30 Ft^2 from upper Louvers and 29.4 Ft^2 from lower. Equaling a total of 59.4 Ft^2 of free area for combustion air.` FSI consulting engineers Job# Beg 15796/FSi 12061 Job Name 14-02 Or Replacement Subject Tukwila Building Division Review Memo Responses Date 6/4/2013 By TLA/BAJ Chkd. Sheet 1 of 1 Permit review comments 11 I in the State of and Responses: 1. _ Please provide a Mechanical Engineer's stamp on the relative pages, Washington one licensed Please see attached revised permit drawing set with Mechanical Engineer's stamps. J 1 1 111 2. Equipment seismic anchorage details need further clarification The number, location, size and type of bolts will need to be added to the plan. The structural calculations submitted also. for these anchor devices should be Please refer to drawing 14-02-5501, with detail 2 added, and corresponding structural calculations, also attached. In addition, notes were details. added to drawing 14-02-1M10, referencing the structural 3. The combustion air grills provided orfthe w ithin 12 inches of the ceiling as new boilers are not located required by the International Fuel Gas Code. What code section was used to calculate this area or is the combustion air an engineered design? Are the new exhaust fans part of the combustion air system? If so, they will need to be interlocked with the boilers to prevent boiler operation when fans are not running. Was the emergency generator included in the combustion air sizing? a. Combustion air meets requirements of 1FGC Section 304.6.1. Please see attached Louver size calculation and refer to drawing 14-02-1M60. b. Duct transitions are being added to the existing louvers so that the openings are within 12" of the ceiling, shown on drawing 14-02-1M60. c. Exhaust fans are for space temperature control only. d. Emergency generator combustion air is calculation. included in total combustion air. See attached louver size 4. Please provide details about the materials -1--L--1_--- used for the boiler breeching and 1 venting. 1 The plans show 4 inches clearance to structure at the roof penetration. Where was this dimension found? Are the Building components combustible or non-combustible? a. Note indicating the specified boiler venting materials has been added to A/M502. Flue is factory - built, modular connector, double wall, stainless steel, Selkirk Metalbestos Model PS, or equal. b. The building is a Type 11 non-combustible building, all components are non-combustible, including the existing tectum roof deck and curb, therefore no clearance is required. c. The existing curb to be reused will provide for about a 4" space, the existing curb and penetration have a sheet metal lining to remain. RECEIVED IT QF TUkWILA E,#.!LL!PN_-_' J ��ILgll, z City of Tukwila May 9, 2013 Connie Hardin 4600 S 134 Place Seattle, WA 98168 Jun Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Correction Letter #1 Mechanical Permit Application Number M13-077 Boeing #14-02 — Boiler Replacement — 8811 East Marginal Wy S Dear Ms. Hardin, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson at 206 431-3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, *fer Marshall it Technician File No. M13-077 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Project Name: Boeing #14-02 Permit # M13-077 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject perniit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36. Please submit all plans on the same size paper. Revised plans need to be the same size as originally submitted). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Please provide a Mechanical Engineer's stamp on the relative pages, one licensed in the State of Washington. 2. Equipment seismic anchorage details need further clarification. The number, location, size and type of bolts will need to be added to the plan. The structural calculations for these anchor devices should be submitted also. 3. The combustion air grills provided for the new boilers are not located within 12 inches of the ceiling as required by the International Fuel Gas Code. What code section was used to calculate this area or is the combustion air an engineered design? Are the new exhaust fans part of the combustion air system? If so, they will need to be interlocked with the boilers to prevent boiler operation when the fans are not running. Was the emergency generator included in the combustion air sizing? 4. Please provide details about the materials used for the boiler breeching and venting. The plans show 4 inches clearance to structure at the roof penetration. Where was this dimension found? Are the building components combustible or non- combustible? Should there be questions concerning the above information please contact the Building Division at 206-431-3670. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: " M13-077 DATE: 06-06-13 PROJECT NAME: BOEING #14-01 - BOILER REPLACEMENT SITE ADDRESS: 8811 EAST MARGINAL WY S Original Plan Submittal Response to Incomplete Letter # _ X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS: Building Division Public Works ❑ Fire Prevention Structural Planning Division n Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 06-11-13 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Notation: n Approved with Conditions DUE DATE: 07-09-13 Not Approved (attach comments) ❑ REVIEWER'S INITIALS: DATE: Permit Center Vse Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 *PERMIT COORD COPf PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER PROJECT NAME: M13-077 BOEING #14-02 DATE: 04/24/13 SITE ADDRESS: 8811 EAST MARGINAL WY S X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: a1- &-eo,\ �-� Building Division El Public Works Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete 1x Incomplete ❑ DUE DATE: 04/25/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 05/23/13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) k Notation: REVIEWER'S INITIALS: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: DATE: • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: .:()5-3 Plan Check/Permit Number:. M13-077 ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Project Addre -�c6(--13/ l Contact Perso „ ��, Phone Number: c%" 6 �_ Summary of Revision: -y~ Boeing #14-01 — Boiler Replacement fILL,tivu� CITY OF TUKWILA 1JUN .UG 2013 �Mi7CENTER Sheet Number(s): 0 55 C)\k VA1.o j "Cloud" or highlight all areas /of revision including date of revition Received at the City of Tukwila Permit Center by: V-- Entered in Permits Plus on (Ps- 3 Contractors or Tradespeople Prr er Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LB:I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HOLADAY PARKS INC UBI No. 578004089 Phone 2062489700 Status Active Address 4600 S 134Th Pl License No. HOLADP1379NO Suite/Apt. License Type Construction Contractor City Seattle Effective Date 1/21/1983 State WA Expiration Date 9/3/2013 Zip 98168 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HOLADI"00105 HOLADAY PARKS INC Electrical Contractor Hvac/Rfrg Ltd Energy Unused 9/25/2000 4/29/2015 Active HOLADPF376NOHOLADAY PARKS FABRCTRS INC Construction Contractor General Unused 8/20/1963 1/1/1983 Archived Business Owner Information Name Role Effective Date Expiration Date PARKS, GERALD T JR Chief Executive Officer 01/21/1983 Amount VAN DER VEEN, JULIE ELIZABETH Member 08/26/2011 A1CG96431203 CONNELL, DANIEL AARON Member 08/26/2011 GIRI, BUIT Member 08/26/2011 Old Republic Ins Co KIEL, RINALD HOWARD Member 08/26/2011 WHITMYRE, CHRISTIAN Member 08/26/2011 24 BECK, DAVID CLARENCE Vice President 01/21/1983 11/01/2012 OCONNOR, BONNY K Vice President 01/21/1983 10/28/2011 NAILON, JUNE ANNETTE Vice President 01/21/1983 VAN DER VEEN, ERIC M Vice President 11/04/2010 PIZZEY, GRACE KATHERINE Vice President 08/26/2011 NELSON, MICHAEL Secretary 01/01/1980 11/04/2010 PARKS, DAVID L Treasurer 01/01/1980 11/04/2010 TALBOT, PAUL Treasurer 01/01/1980 11/04/2010 Bond Information Bond Company Name LIBERTY MUTUAL INS CO Bond 7 Page 1 of 2 Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 23000452 09/01/2002 Until Cancelled $12,000.00 08/23/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 26 Old Republic Ins Co A1CG96431203 11/01/2012 11/01/2013 $1,000,000.00 10/30/2012 25 Old Republic Ins Co A1CG96431102 11/01/2011 11/01/2012 $1,000,000.00 10/28/2011 24 Old Republic Ins Co A1CG96431102 11/01/2011 11/01/2012 $1,000,000.00 10/28/2011 httns://fortress.wa. eov/lni/bbin/Print. asnx 06/14/2013 BOEING SHARED SERVICE GROUP BUILDING 14-02 THOMPSON SITE vICI ITY v1AP THOV PSO \ SITE 8811 EAST MARGINAL WAY SOUTH TUKWILA, WASHINGTON 98108 AREA N AP 3UILD1\G ADDHSS: 8811 EAST VAGI\AL WAY SOUTH TU<WILA, WASHI\GTO\ 1111111111111111111111111111111111111111111111111111 1111""1 111111111111111111111 nn�irnn�murw..�.nx�rrurr�xrnx 14-02 SEPARATE PERMIT REQUIRED FOR 3UILOI\ G LOCATIO ❑ Mechanical E lelectrical DrPiumbing as Piping City of Tukwila k=LDli\IG DIVISION_ REVISIONS No chanpe, shall be made to the scope of work without prior approval of u` ,,rola Building Division. t,7777: i,^ will require a new plan submittal ci , `i may add'tional plan review feCS. FILE COPY Permit No.. 1S- 077 PI review approval is subject to errors and omissions. £r::kr:::.;TI.F,1 01 con truction documents does not authorize tiof any adopted code or ordinance. Receipt ni approved wledged: By Date: City Of'tiukwita BUILDING DIVISION CODE SU v v ERY TYPE OF APPLICATION: NEW ❑ ALTERATION ❑ ADDITION ❑ TENANT IMPROVEMENT II PROJECT DESCRIPTION: THE PRIMARY OBJECTIVE OF THIS PROJECT IS TO PROVIDE DESIGN SERVICES TO REMOVE EXISTING BOILERS FROM THE 14-02 FACILITY AND PLACE NEW BOILERS ON THE EXISTING PADS AND RECONNECT ALL PIPING AND CONTROLS AS DETAILED IN DRAWINGS AND SPECIFICATIONS. WORK INCLUDES PROVIDING ADDITIONAL LOUVER AREA FOR BOILER COMBUSTION AIR, AND REPLACING A PAIR OF DAMAGED DOORS. CODES: 2009 INTERNATIONAL BUILDING CODE & WAC 51-50 2009 INTERNATIONAL MECHANICAL CODE & WAC 51-52 2009 INTERNATIONAL FIRE CODE & WAC 51-54 2009 UNIFORM PLUMBING CODE & WAC 51-56 2009 UNIFORM PLUMBING CODE AMENDMENTS A, B & I & WAC 51-57 2008 NATIONAL ELECTRIC CODE, AMENDMENTS A, B & C & WAC 296-46B-010 2009 WASHINGTON STATE ENERGY CODE WAC 51-11 CURRENT CITY OF TUKWILA ZONING ORDINANCES CONTRACTOR & STATE NUMBER: THE BOEING CO. BOEINC *294ML(OV2009) BOEING PROJECT ENGINEER. TOM ANDERSON, FSI ENGINEERS 206-622-3321 BOEING CONTACT: JOHN MURDOCH FAX NUMBER. 253-657-0858 PHONE: 253-657-0868 E—MAIL. Iohn.s.murdoch©boeinq.com OCCUPANCY GROUP. GROUP FI FACTORY CONSTRUCTION TYPE: TYPE II—B ZONING: ALLOWABLE AREA INCREASE. SPRINKLERED & 60' SET—BACK (NO CHANGES) OCCUPANT LOAD: (ALLOWABLE) NO CHANGE FLOOR AREA: (ACTUAL) NO CHANGE (TABLE 10—A) OFFICES OCC BLDG GROSS STORAGE OCC. TUNNEL LABORATORY OCC FIRST FLOOR 3,080 SF CANOPY OCC. 1ST FLR MEZZ OTHER OCC. 2ND FLOOR 2ND FLOOR ME77 PROJECT AREA 3,080 SF SQ FT SQ FT SQ FT SQ FT SQ FT SQ FT SQ FT BUILDING HEIGHT: (ACTUAL) 24 FT STORIES: 1 3,080 SF MEZZANINE ? ❑ ()Es) El (No) FIRE PROTECTION: SPRINKLERED THROUGHOUT PER NFPA 13 ?• SQ FT (YES) ❑ (NO) SEPARATION EXTERIOR WALL (NON—BEARING) HOUR RATING EXTTERIOR WALL (BEARING) HOUR RATING INTERIOR WALL (NON—BEARING) HOUR RATING INTERIOR WALL (BEARING) HOUR RATING DEMOUNTABLE PARTITIONS HOUR RATING STRUCTURAL FRAME HOUR RATING FLOOR/CEILINGS HOUR RATING ROOF CONSTRUCTION HOUR RATING SEISMIC DESIGN: ZONE D DESIGN LOADS: (CHAPTER 16) ROOF: LIVE (SNOW) (PSF) FLOOR: OFFICE (PSF) MECH/STOR (PSF) STAIRS (PSF) CORRFCTION CONCENTRATED: 1 •rc�. CODES A \ID PERMITS PROJECT TITLE: 14-02 BOILER REPLACEMENT JOB NUMBER: #15796 QUANTITY SUBMITTED: ❑ 5 SETS: GENERAL PERMIT (SHELL & CORE) OR STRUCTURAL TENANT IMPROVEMENT 4 SETS: TENANT IMPROVEMENT (NON—STRUCTURAL) ❑ 3 SETS: FIRE PROTECTION/SPRINKLERS ❑ 2 SETS: TENANT IMPROVEMENT (REVISION) SUBMITTED FOR PERMIT & REVIEW: ❑ BUILDING ❑ GRADING ❑ ELECTRICAL* ❑ PLUMBING ❑ LANDSCAPE ❑ FIRE PROTECTION ❑ MECHANICAL* ❑ DEMOLITION ❑ CANTILEVER RACKS ❑ STRUCTURAL ❑ ❑ - * TO BE REVIEWED UNDER SEPARATE PERMIT WASHINGTON STATE NON—RESIDENTIAL ENERGY CODE—APPROACHES COMPLIANCE OPTION ❑ PRESCRIPTIVE ❑ LPA ❑ ANALYSIS • N/A SPECIAL INSPECTIONS REQUIRED: ❑ WELD ❑ CONCRETE ❑ REBAR ❑ ANCHOR BOLTS ❑ STRUCTURAL BOLTING ❑ STRUCTURAL OBSERVATION ❑ OTHER CALCULATIONS TYPE• N/A ATTACHED (YES) (NO) DRAWI\G I\DEX SHEET DRAWING SHEET TITLE N0. N0. GO 14-02—GO TITLE SHEET 1 Al OR 14-02-1 Al OR FIRST FLOOR PLAN RFA16OR 14-02—RFA16OR ROOF PLAN 1A10 14-02-1A10 FIRST FLOOR PLAN 1A350 14-02-1A350 DOOR SCHEDULE AND DOOR TYPE RFA160 14-02—RFA160 ROOF PLAN RFA500 14-02—RFA500 ROOF DETAIL S501 14-02—S501 DETAILS M1 14-02—M1 LEGEND AND ABBREVIATIONS 1M6OR 14-02-1M6OR HVAC PIPING PLAN — REMOVAL 1M60 14-02-1M60 HVAC PIPING PLAN M501 14-02—M501 HEATING WATER DIAGRAM AND SCHEDULES M502 14-02—M502 DETAILS 1 E11 OR 14-02-1 E110R 277/480 VOLT POWER PLAN — REMOVAL 1E21OR 14-02-1E210R CMCS PLAN - REMOVAL E502R 14-02-E502R MCC #5 ELEV & EQUIP LIST DETAIL — BOILER HOUSE — REMOVAL 1E60 14-02-1E60 120/208 VOLT POWER PLAN 1E110 14-02-1E110 277/480 VOLT POWER PLAN 1E210 14-02-1E210 CMCS PLAN E502 14-02-E502 MCC #5 ELEV & EQUIP LIST DETAIL - BOILER. VIEWED `ODE COMPI APPROV GENERAL \OTES CONSTRUCTION SET OF DOCUMENTS, REVIEWED AND STAMPED BY CITY OF TUKWILA MUST BE! SITE DURING CONSTRUCTION. DO NOT PROCEED WITH CONSTRUCTION WITHOUT ABOVE MENTIONED SET OF DOCUMENTS. 1. VERIFY ALL DIMENSIONS AND CONNECTIONS BEFORE ANY WORK. 2. NOTIFY FACILITY ENGINEERS SHOULD EXISTING CONDITIONS REQUIRE DESIGN REVISIONS. 3. COORDINATE WORK WITH OTHER CRAFTS. 4. RETURN THIS SAME SET TO THE CONSTRUCTION MANAGER AFTER COMPLETION. FOR IANC 'JUN 132013 City of Tukwila UILDING DIVISIOP RECEIVED CITY OF TUKWILA JUN 0,6 2013 PERMIT CENTER Mia- a77 ISSUED FOR CONSTRUCTION SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A 14-02 BOILER REPLACEMENT 15796 FSi 12.21.12 B PERMIT REVISIONS 15796 FSi 06.03.13 STEVE WEIDNER BOE/NG' o -- 12.21.12 smNE) ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE TITLE SHEET CURRENT REVISION 15796 • FSI consulting engineers Seattle, Washington Solutions & Servic 3 SYMBOL DATE 06.3.1' APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14-02 THOMPSON, WA SHEET GO JOB NO. COMP NO. . DWG NO. 14-02—GO SYM REVISION 3 TS 3x3x3/16 TYP LEGEND WALL TO BE REMOVED - e - � t �- W8x20 TYP. CONCRETE CURB W/STEEL PLATE TRENCH RAILING `—..., SUMP -) LAQDER � T BY APPROVED DATE SYM REVISION BY APPROVED DATE - 14-02 BOILER REPLACE 15793 RAI 12.21.12 ro./NG° cY- 6250 REGISTERED I ARCLi�E tiT Alex E. Rolluda STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED GE \EAL \OTES EFERE\CE D AWINGS v OVAL OTES REMOVE EXISTING HM DOOR AND DOOR FRAME. SAW CUT OPENING TO RECEIVE LOUVER IN WALL PANEL. SEE MECHANICAL. 3 -077 REVIEWED FOR ODE COMPLIANCE APPROVED IJUN132013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0,6 2013 PERMIT CENTER PERMIT SUBMITTAL CHECKED REMOVAL FIRST FLOOR PLAN APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER BUILDING 14-02 COL. A -F/1-4 CURREN ( REVISION SYMBOL 15796 0 SHEET JOB NO. THOMPSON DWG NO. IAIOR 14-002-1A1OR SYM REVISION 1A350 EXISTING ASPHALT RAM P TS 3x3x3/16 TYP BY APPROVED 14-02 BOILER REPLACE 15793 RAI DATE 12.21.12 SYM REVISION BY APPROVED DATE 6250 1 REGISTERED Alex E. Rolluda STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE VI(3 LEGE\D 602 DOOR LOUVER GE\HAL OTES FOR DOOR SCHEDULE AND DETAILS SEE SHEET 1A350. EFHE\CE NAWI\GS CO\STRUCTIC\ \OTES REPLACE EXISTING HM DOOR AND DOOR FRAME. INCLUDE LOUVER IN NEW DOOR SET. PROVIDE NEW LOUVER GRILLE (48" x 90"). CENTER ON PANEL. SEE MECHANICAL. 7 7 1 PERMIT SUBMITTAL FIRST FLOOR PLAN APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER BUILDING 14-02 COL. A -F/1-4 REVIEWED FOR CODE COMPLIANCE APPROVED !JUN 132013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0.62013 PERMIT CENTER CURRENT REVISION 15796 SHEET SYMBOL° 1A10 SIG DATE JOB NO. COMP NO. co( THOMPSON Dwc No. 14-002-1A10 � ZI z w W8x20 TYP. of CONCRETE CURB x � a W/STEEL PLATE UI TRENCH RA LING SUMP ) J� T LAQDER -�L BY APPROVED 14-02 BOILER REPLACE 15793 RAI DATE 12.21.12 SYM REVISION BY APPROVED DATE 6250 1 REGISTERED Alex E. Rolluda STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE VI(3 LEGE\D 602 DOOR LOUVER GE\HAL OTES FOR DOOR SCHEDULE AND DETAILS SEE SHEET 1A350. EFHE\CE NAWI\GS CO\STRUCTIC\ \OTES REPLACE EXISTING HM DOOR AND DOOR FRAME. INCLUDE LOUVER IN NEW DOOR SET. PROVIDE NEW LOUVER GRILLE (48" x 90"). CENTER ON PANEL. SEE MECHANICAL. 7 7 1 PERMIT SUBMITTAL FIRST FLOOR PLAN APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER BUILDING 14-02 COL. A -F/1-4 REVIEWED FOR CODE COMPLIANCE APPROVED !JUN 132013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0.62013 PERMIT CENTER CURRENT REVISION 15796 SHEET SYMBOL° 1A10 SIG DATE JOB NO. COMP NO. co( THOMPSON Dwc No. 14-002-1A10 30"x54" LOUVER DOOR & LOUVER SCHEDULE DOORDOOR MARK FRAME HDWR CLOSER LOUVER DETAILS NOTES SIZE THKNS TYPE MAT FINISH TYPE MAT FINISH RATING HEAD JAMB SILL 602 8'-0" x 7'-0" 1 3/4" A HM PAINT B HM PAINT 1 - 30"x54" 6/A350 6/A350 5/A350 REPLACE FRAME NEW HARDWARE : CYLINDER LEVER, SURFACE MOUNTED SLIDE BOLT AT TOP AND BOTTOM AT FIXED LEAF LO1 48" x 90" - - - - - - - - - - 48"x90" 3/A350 2/A350 1/A350 REINFORCE OPENING PER STRUCTURAL. SEE MECHANICAL FOR LOUVER SPECIFICATION. FIXED LEAF ACTIVE LEAF 73,, A n ,, 73A 0 9" A DOOR TYPES 8'-O" FIELD VERIFY D REPLACE FRAME C FRAN ES FIELD VERIFY as 16" CONC. WALL SEE STRUCTURAL PREP FRAME TO RECEIVE DEAD BOLT. FIXED LEAF ONLY. 18 GA. HM FRAME GROUT SOLID 18 GA. HM DOOR /SURFACE MOUNTED DEAD BOLT AT TOP AND BOTTOM OF FIXED LEAF 6 DOOR HEAD/JA SCALE: 3" 1'-O" VI3 AT CO \C. SURFACE MOUNTED DEAD BOLT AT TOP AND BOTTOM OF FIXED LEAF 18 GA. HM FRAME 18 GA. HM DOOR 900 THRESHOLD SCALE: 3" 1'-0" DUST PROOF STRIKE CENTER LOUVER ON PANEL 1A350 7'-6" 9„ EQ LIDC) EQ WALL PA\ EL ELEVATI O SCALE: NTS INTERIOR LOUVER HEAD 3 SCALE: 3" = 1'-0" INTERIOR OUTSIDE CONCRETE PANEL BACKER ROD AND SEALANT CONTINUOUS EACH SIDE - 20 GA STAINLESS STEEL DRIP FLASHING LOUVER LOUVER JAN 3 2 SCALE: 3" = 1'-0" INTERIOR SILL OUTSIDE CONCRETE PANEL BACKER ROD AND SEALANT CONTINUOUS EACH SIDE GENERAL FRA v E A\ D DOOR NOTES HA PROVIDE FRAMES WITH THROATS TO ACCOMMODATE WALLS IN WHICH DOORS ARE LOCATED, EXCEPT WHERE INDICATED OTHERWISE ON PLAN DETAILS. ALL DOORS SHALL BE 1 3/4" THICK UNLESS OTHERWISE NOTED. SEE DOOR SCHEDULE FOR DOOR AND FRAME FINISHES. DOOR EDGES TO MATCH FINISHES OF DOOR SURFACES. ADJUST EXIST. DOORS WITHIN AREA OF WORK TO ACHIEVE POSITIVE LATCHING. DOOR FRAMES HUNG WITH LABELED DOORS SHALL ALSO BE LABELED TO MATCH THAT OF DOOR FOR OVERALL ASSMEBLY RATING. DWARE GRO P 6EA HINGES 1EA LOCKSET 1EA ASTRAGAL 1EA WEATHERSTRIP 2EA SURFACE BOLTS 2EA DOOR SWEEPS 2EA DUST PROOF STRIKES LOUVER - INSTALL PER MANUFACTURER RECOMMENDATIONS. 3/8" EXPANSION ANCHOR MINIMUM AT 24" 0.C. TOP AND SIDES LOUVER THRESHOLD SCALE: 3" = 1'-0" OUTSIDE LOUVER 20 GAGE STAINLESS STEEL SILL PAN FULLY SOLDERED, SET IN SEALANT. CONCRETE PANEL 1 " UP TURN DRIP TRAY PERMIT SUBMITTAL HAGER BB1199 5"X4.5" US32D YALE B-AU5405LN US26D PEMKO 357SP 84" PEMKO S88D 25' HAGER 275D PEMKO 315CN 48" ROCKWOOD 570 REVIEWED FOR CODE COMPLIANCE APPROVED !JUN 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 062013 PERMIT CENTER SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 14-02 BOILER REPLACE 15796 RAI 12.21.12 BOE/NG' o-- 6250 REGISTERED I ART AIe Rolluda STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE DOOR SCHEDULE AND DOOR TYPE CURRENT REVISION 15796 SYMBOL° SIG DA .21.12 APPROVED BY DEPT. DATE NCINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER BUILDING 14-02 COL. A -F/1-4 THOMPSON SHEET 1A350 JOB NO. COMP NO. DWG NO. 14-002-1A350 75'-0" (s) 15' ff 15'-0" 15'-0" 15'-0" 15'-0" r. 0 14.02 BUILDING BEYOND WITH HIGHER ROOF ROOF PLAN SCALE: 1 /4"=1'-0" EXISTING LIGHT REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 14-02 BOILER REPLACE 15796 RAI 12.21.12 BOE/NG' rY- 6750 REGISTERED AR t Alex E. STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PERMIT SUBMITTAL UA I t SUBTITLE DRA1 CHECKED LEGE \ D GE \ E RAL \OTES EFRE\CE DRAWI \GS EV1OVAL \CITES REMOVE EXISTING FLASHING AND SHEET METAL AT FLUE REMOVAL. SEE MECHANICAL. 77 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN;0 6 2013 PERMIT CENTER REMOVAL ROOF PLAN DATE 15796 U--) Ir, 1,.2 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER BUILDING 14-02 COL. A -F/1-4 THOMPSON =HEETRFA160R JOB NO. COMP NO. DWG NO. 14-002-RFA160R EXISTING LIGHT 0 RD // \\ / \ / \ QXISTING ROOF HATCH 0 RV 0 RD 1 1 `'''"- EXHAUST FAN VENT 1 1 `''-"� 1 EXHAU FAN T 0 0 — — — — — Q— — F — XIS T TNG VENT --II li 0 _ ,, EXISTING LIGHT 0 RD EXHAUST PIPE 14.02 BUILDING BEYOND WITH HIGHER ROOF ROOF PLAN SCALE: 1 /4"=1'-0" EXISTING LIGHT REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 14-02 BOILER REPLACE 15796 RAI 12.21.12 BOE/NG' rY- 6750 REGISTERED AR t Alex E. STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED PERMIT SUBMITTAL UA I t SUBTITLE DRA1 CHECKED LEGE \ D GE \ E RAL \OTES EFRE\CE DRAWI \GS EV1OVAL \CITES REMOVE EXISTING FLASHING AND SHEET METAL AT FLUE REMOVAL. SEE MECHANICAL. 77 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN;0 6 2013 PERMIT CENTER REMOVAL ROOF PLAN DATE 15796 U--) Ir, 1,.2 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER BUILDING 14-02 COL. A -F/1-4 THOMPSON =HEETRFA160R JOB NO. COMP NO. DWG NO. 14-002-RFA160R SYM REVISION 75'-0" 15-0 .11 15-0" 15-0" 15-0" 15 - If 14.02 BUILDING BEYOND WITH HIGHER ROOF BY APPROVED 14-02 BOILER REPLACE 15796 RAI DATE 12.21.12 SYM REVISION BY APPROVED DATE rzzer.rivG' o'— EXISTING LIGHT d— I 6250 REGISTERED AR� Ale R011uda STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE LEGE\ D GE\ERAL \OTES EFHE\CE DRAWINGS CONSTRUCTIO \ \OTES PROVIDE NEW STAINLESS STEEL FLASHING WITH SQUARE TO ROUND TRANSITION AND GUY WIRE, SEE MECHANICAL. INSTALL STAINLESS STEEL CAP OVER CURB, SEE MECHANICAL. t#4 13-0 7 7 1 PERMIT SUBMITTAL ROOF PLAN APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE BUILDING 14-02 ARCHITECTURAL MASTER COL. A -F/1-4 CURRENT REVISION 15796 REVIEWED FOR {' QDE COMPLIANCE APPROVED IJUN 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0,6 2013 PERMIT CENTER SYMBOL0 SHEET RFA160 JOB NO. RI G DATE COMP NO. THOMPSON DWG NO. 14-002-RFA160 — — — — EXISTING LIGHT 0 RD / \ / \ / \ QXISTING ROOF HATCH 1 0 RV 0 RD EXHAUST FAN VENT EXHAU FAN T 0 0 — — Q., H — - ING VENT 2i 1 11 3 RFA 01 2 RFA501 - -,, EXISTING LIGHT 0 RD EXHAUST PIPE 14.02 BUILDING BEYOND WITH HIGHER ROOF BY APPROVED 14-02 BOILER REPLACE 15796 RAI DATE 12.21.12 SYM REVISION BY APPROVED DATE rzzer.rivG' o'— EXISTING LIGHT d— I 6250 REGISTERED AR� Ale R011uda STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE LEGE\ D GE\ERAL \OTES EFHE\CE DRAWINGS CONSTRUCTIO \ \OTES PROVIDE NEW STAINLESS STEEL FLASHING WITH SQUARE TO ROUND TRANSITION AND GUY WIRE, SEE MECHANICAL. INSTALL STAINLESS STEEL CAP OVER CURB, SEE MECHANICAL. t#4 13-0 7 7 1 PERMIT SUBMITTAL ROOF PLAN APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE BUILDING 14-02 ARCHITECTURAL MASTER COL. A -F/1-4 CURRENT REVISION 15796 REVIEWED FOR {' QDE COMPLIANCE APPROVED IJUN 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0,6 2013 PERMIT CENTER SYMBOL0 SHEET RFA160 JOB NO. RI G DATE COMP NO. THOMPSON DWG NO. 14-002-RFA160 TYP FLUE PE\ SCALE: 1/2" = 1'-0" ET PATIO \ FLUE PER MECHANICAL HIGH TEMP SEALANT AND S.S. CLAMP AT DRIP SKIRT S.S. SHEET METAL FLASHING ENCLOSURE, SEE DETAIL 1/RFA500 SUPPORT PER MANUFACTURER CONT. S.S. CLEAT TYP. EXISTING ROOF AND CURB TO REMAIN 4" MIN A\ D STAC < SUPPO EXISTING PIPE SUPPORT NOTE: 1.PROVIDE CLEARANCES REQUIRED BY CODE AND FLUE MANUFACTURER. NEW FLUE PER MECHANICAL • LAP :1-" RIVET Sc SEAL FLUE PENETRATIO (1ISOVETlC SCALE: 3" = 1'-0" SHEET METAL FLASHING ENCLOSURE EXISTING ROOFING TO REMAIN A\D STAC < SUPPORT 304 STAINLESS STEEL SHEET METAL CAP AT EXISTING ROOF CURB SELF -ADHERING MEMBRANE 1 1/4" EXTERIOR GRADE PLYWOOD EXISTING ROOFING AND CURB TO REMAIN (CAP AT EX I STI \ 3) SCALE: 3" = 1'-0" G CU 3 SYM REVISION BY APPROVED 14-02 BOILER REPLACE 15796 RAI DATE 12.21.12 SYM REVISION BY APPROVED DATE Q�BOE/NG' o�- 8258 1 REGISTERED I Ale RoIIuda STATE OF WASHINGTON ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED SUBTITLE PERMIT SUBMITTAL 1 ROOF DETAILS APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE ARCHITECTURAL MASTER BUILDING 14-02 COL. A -F/1-4 THOMPSON CURRENT REVISION . 15796 REVIEWED FOR 'CODE COMPLIANCE APPROVED JUN 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0,6 2013 PERMIT CENTER SYMBOL° SHEET RFA500 JOB NO. DATE 12c COMP NO. DWG NO. 14-002-RFA500 SYM SEISMIC ANCHORAGE FOR HW BOILER (TYPICAL, TOTAL OF 6) SEE DETAIL 3/S501 W EST ILEVATIO\ (GRID LINE 1) SCALE: 3/16" = 1'-0" HOT WATER BOILER A[\ C (1� S501 H.W. BOILER BASE (SEE MECH.) N BOLTS PLA\ t, 4'- A ' - A S501 SEISMIC ANCHORAGE FOR TANK (TOTAL OF 4) SEE DETAIL 3/S501 SCALE: N.T.S. EXPANSION TANK �2 S501 EXPANSION TANK BASE (SEE MECH.) EQUIPMENT BASE 3"0 BOLTS TO EQUIPMENT BASE EXTERIOR INTERIOR 4 - EXISTING COLUMN BEYOND EXISTING GIRT (DIAGONAL BRACINGS ARE NOT SHOWN FOR CLARATY) SECTIO\ SCALE: 1 " = 1 (78\- S501 STEEL ANGLE L21/2"x2Y2"x1 " (3" LONG) PER PLAN "00%" HILTI KB -TZ ANCHOR BOLTS (21/" EMBED) LA ANCHOR BOLT DETAIL DETAIL SCALE: N.T.S. S501 W w m REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 14-02 BOILER REPLACE 15796 A REVISED PER CITY COMMENT 15796 SC SC 12.19.12 05.30.13 ACCEPTABILITY THIS . DESIGN AND/OR SPECIFICATION IS APPROVED APPROVED BY DEPT, DATE DRAWN SC DATE 12.19.12 CHECKED SUBTITLE LEGE GE\HAL \OTES EFHE\CE I'AWI\GS 4-01 -10 -S4 14-002-1M60 CO\STJCTIO ECA WA PANELS HVAC PIPING PLAN OTES NEW 4'-0"x7'-6" OPENING ON EXISTING CONCRETE WALL PANEL FACADE. NEW 3/8"x3"x8'-0" LONG PLATE AT TOP & BOTTOM OF OPENING WITH HILTI KB -TZ (".0x3Y4") ANCHOR BOLTS. @ 18" 0.C. HILTI KB -TZ (" 0x3Y ") ANCHOR BOLTS AT (4) LOCATIONS PER MECHANICAL DRAWING. V1(3 N- 7 7 DETAILS CURRENT REVISION 15796 REVIEWED FOR DE COMPLIANCE APPROVED JUN 13 2013 `r. City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN ;0.6 2013 PERMIT CENTER SYMBOL A DATE 05.30.13 ENGINEER SC CHECKED APPROVED APPROVED 12.19.12 TITLE STRUCTURAL MASTER BUILDING 14-002 THOMPSON, WA SHEET S501 JOB NO. COMP NO. DWG NO. 14-002-S501 NG308C: 5/30/2013 9:56:11 GENERAL LEGEND t NORTH ARROW DETAIL, DRAWING REFERENCE SECTION REFERENCE CONSTRUCTION NOTE REVISION SYMBOL POINT OF CONNECTION BOLD LINE WEIGHT INDICATES NEW WORK LIGHT LINE WEIGHT INDICATES EXISTING SLASHED LINE INDICATES EXISTING WORK TO BE DEMOLISHED VENTILATION LEGEND SINGLE LINE DUCTWORK INDICATES VIEW DIMENSION LESS THAN 12 INCHES �---® I DQ © I i,>1 p + I I.-1 SUPPLY OR EXHAUST TAKEOFF SUPPLY DUCT TURNING TOWARD SUPPLY DUCT TURNING AWAY EXHAUST DUCT TURNING TOWARD EXHAUST DUCT TURNING AWAY o 4. I ROUND DUCT TURNING TOWARD 1 «) ROUND DUCT TURNING AWAY TRANSITION 3 D i CpSD MD 4 FVD VD FD z F-1 SMOKE DAMPER MOTORIZED DAMPER VOLUME DAMPER FIRE DAMPER HUMIDIFIER ACCESS DOOR, ACCESS PANEL FLEXIBLE CONNECTION TURNING VANES FLEXIBLE DUCT 2'x2SUPPLY DIFFUSER 2' DIAMETER SUPPLY DIFFUSER 1'x2' EXHAUST GRILLE 2'x2' EXHAUST GRILLE 2'x4' EXHAUST GRILLE HUMIDISTAT THERMOSTAT EQUIPMENT TAG PLUMBING LEGEND 1— XX- 1 a1 1V Jw I4 DOMESTIC COLD WATER (CW) DOMESTIC HOT WATER (HW) DOMESTIC HOT WATER CIRCULATING (HWC) SOIL, WASTE (S,W) VENT (V) PIPING IDENTIFIER, SEE ABBREVIATIONS ELBOW DOWN ELBOW UP TEE TEE DN TEE UP ANGLE VALVE ISOLATION OR SHUT—OFF VALVE (NO), TYPE AS ISOLATION OR SHUT—OFF VALVE (NC), TYPE AS THROTTLING VALVE, TYPE AS SPECIFIED BALANCING VALVE METERING BALANCING VALVE CHECK VALVE CONTROL VALVE 3—WAY CONTROL VALVE ISOLATION OR SHUT—OFF VALVE (NO), TYPE AS ISOLATION OR SHUT—OFF VALVE (NC), TYPE AS THROTTLING VALVE (NO), TYPE AS SPECIFIED THROTTLING VALVE (NC), TYPE AS SPECIFIED PLUG VALVE PRESSURE REDUCING VALVE SOLENOID VALVE ANGLE VALVE(PLAN VIEW) CAP BLIND FLANGE EXPANSION JOINT REDUCER PRESSURE GAUGE STRAINER UNION AIR VENT, TYPE AS SPECIFIED PRESSURE/TEMPERATURE TAP TEMPERATURE GAUGE GENERAL NOTES SPECIFIED SPECIFIED SPECIFIED SPECIFIED PROVIDE POST CONSTRUCTION COMMISSIONING AND COMPLETION REQUIREMENTS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE, SECTION 1416 AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE SPECIFICATION SECTIONS 23 05 00, 23 09 00 AND ALL OTHER APPLICABLE SPECIFICATION SECTIONS. BALANCE ALL HVAC SYSTEMS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE, GENERALLY ACCEPTED ENGINEERING STANDARDS AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE SPECIFICATION SECTION 23 05 93 AND ALL OTHER APPLICABLE SPECIFICATION SECTIONS. 3. PROVIDE CONTROLS IN ACCORDANCE WITH THE WASHINGTON STATE ENERGY CODE, SECTION 1412 AND IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. SEE TEMPERATURE CONTROL SPECIFICATION SECTIONS AND ALL OTHER APPLICABLE SPECIFICATION SECTIONS. ABV AD ADDN AFF ALT AP APPROX ARCH AUX BAL BLDG BSMT BTU BTU H CAP CL CLG CMU COND COL CONC CONN CONST CONT CONTR COORD D DEG DIA DIAG DIFF DIM DISCH DIV DN DP DR DWG EA EFF ELEC ELEV EMCS ENT EQ EQUIP ET EWT EX, (E) EXP EXPL F FIO FIN FLEX FLR FOIC FP FT GA GAL GC GEN GPM GWB H HOA HOR HP HR HZ IBC ID IFC IMC IN INFO INSUL KW KWH L LAB LAV LB GENERAL ABBREVIATIONS ABOVE ACCESS DOOR ADDITION, ADDITIONAL ABOVE FINISHED FLOOR ALTERNATE ACCESS PANEL APPROXIMATELY ARCHITECT; ARCHITECTURAL AUXILIARY BALANCING BUILDING BASEMENT BRITISH THERMAL UNIT BRITISH THERMAL UNITS PER HOUR CAPACITY CENTERLINE CEILING CONCRETE MASONRY UNIT CONDENSATE COLUMN CONCRETE CONNECT; CONNECTION CONSTRUCTION CONTINUOUS; CONTINUATION CONTRACTOR COORDINATE DEEP (DIM) DEGREE DIAMETER DIAGONAL; DIAGRAM DIFFERENTIAL DIMENSION DISCHARGE DIVISION DOWN DIFFERENTIAL PRESSURE DRAIN DRAWING EACH EFFICIENCY ELECTRICAL ELEVATION; ELEVATOR ENERGY MANAGEMENT CONTROL SYSTEM ENTERING EQUAL EQUIPMENT EXPANSION TANK ENTERING WATER TEMPERATURE EXISTING EXPOSED EXPLOSION FAHRENHEIT FURNISHED Sc INSTALLED BY OWNER FINISHED FLEXIBLE FLOOR FURNISHED BY OWNER, INSTALLED BY CONTRACTOR FIRE PROTECTION; FREEZE PROTECTION FEET; FOOT; FEET OF WATER(PRESS) GAGE; GAUGE GALLON GENERAL CONTRACTOR GENERAL GALLONS PER MINUTE GYPSUM WALLBOARD HEIGHT; HIGH HAND OFF AUTOMATIC HORIZONTAL HORSE POWER HOUR HERTZ INTERNATIONAL BUILDING CODE INSIDE DIAMETER INTERNATIONAL FIRE CODE INTERNATIONAL MECHANICAL CODE INCH INFORMATION INSULATE; INSULATION KILOWATT KILOWATT HOUR LENGTH; LONG (DIM) LABORATORY LAVATORY POUND SYM REVISION A 14-02 BOILER REPLACEMENT 15796 BY FSi APPROVED DATE SYM REVISION BY APPROVED DATE 12.14.12 Q� w4vivi' LBS/HR LF LO LTG LVG LWT MAT MAX MBH MCC MECH MED MFG M FR MIN MISC MTD MTG MTL N NA NC NIC NO NOM NTS OC OD OPP PD PERF PERP PH POC PRELIM PRESS PROP PS PSI PSIG PT QTY QUANTITY POUNDS PER HOUR LINEAL FEET LOW LIGHTING LEAVING LEAVING WATER TEMPERATURE MATERIAL MAXIMUM THOUSAND BRITISH THERMAL UNITS PER HOUR MOTOR CONTROL CENTER MECHANICAL; MECHANICAL CONTRACTOR MEDIUM MANUFACTURING MANUFACTURER MINIMUM; MINUTE MISCELLANEOUS MOUNTED MOUNTING M ETAL NORTH NOT APPLICABLE NORMALLY CLOSED NOT IN CONTRACT NORMALLY OPEN; NUMBER NOMINAL NOT TO SCALE ON CENTER OUTSIDE DIAMETER; OVERALL DIMENSION OPPOSITE PRESSURE DROP PERFORATED PERPENDICULAR PHASE POINT OF CONNECTION PRELIMINARY PRESSURE PROPERTY; PROPOSAL PRESSURE SWITCH POUNDS PER SQUARE INCH POUNDS PER SQUARE INCH GAGE PRESSURE/TEMPERATURE TAP R RAD REF REFR REQD RET RM RPM S SCHED SECT SF SHT SIM SOL SPEC SPECD SQ STD STRUCT TBD TD TEMP TH THRU TYP UBC UL UTI L V VAR VEL VERT VOL W W/ W/0 WT YD YR RADIUS; RETURN; RISER RADIATOR REFERENCE REFRIGERATION REQUIRED RETURN ROOM REVOLUTIONS PER MINUTE SOUTH SCHEDULE SECTION SQUARE FEET SHEET SIMILAR SOLENOID SPECIFICATION SPECIFIED SQUARE STANDARD STRUCTURAL TO BE DETERMINED TEMPERATURE DIFFERENTIAL TEMPERATURE TOTAL HEAD THROUGH TYPICAL UNIFORM BUILDING CODE UNDERWRITER'S LABORATORY UTILITY VOLT VARIABLE VELOCITY VERTICAL VOLUME WATER; WIDE(DIM); WATT WITH WITHOUT WEIGHT YARD YEAR 1 ISSUED FOR CONSTRUCTION SUBTITLE ,2.2,.,2 s,N„D ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED AL AC AD AF AHU BDD BHP BI BOD C CC CFM CG CLG CLWR C LWS COND CT CV CWR CWS DDC DMPR DB EA EAT EF EG EXH FA FC FCU FD FF FPM FS FV GALV GR H HC HPC HPS HTG HV HWR HWS HX IMC AW A BOP CI CF CIRC CW CO CA DI DW DOM DR DF ES FCO FD FOR FOS FOV FPHB G GPH HB HW HWC IPC IW JAN HVAC ABBREVIATIONS ACOUSTIC LINED; ALUMINUM AIR CONDITIONING AUTOMATIC DAMPER AIR FOIL AIR HANDLING UNIT BACKDRAFT DAMPER BRAKE HORSEPOWER BACKWARD INCLINED BOTTOM OF DUCT CONDENSATE; COMMON COOLING COIL CUBIC FEET PER MINUTE CEILING GRILLE COOLING COOLING WATER RETURN COOLING WATER SUPPLY CONDENSATE COOLING TOWER CONSTANT VOLUME CHILLED WATER RETURN CHILLED WATER SUPPLY DIRECT DIGITAL CONTROLS DAMPER DRY BULB TEMPERATURE(°F) EXHAUST AIR ENTERING AIR TEMPERATURE EXHAUST FAN EXHAUST GRILLE EXHAUST FACE AREA FAN COIL; FORWARD CURVED FAN COIL UNIT FIRE DAMPER FINAL FILTER FEET PER MINUTE FLOW SWITCH FACE VELOCITY GALVANIZED GRILLE HUMIDIFIER, HUMIDISTAT HEATING COIL HIGH PRESSURE CONDENSATE HIGH PRESSURE STEAM HEATING HEAT AND VENT UNIT HEATING WATER RETURN HEATING WATER SUPPLY HEAT EXCHANGER INTERNATIONAL MECHANICAL CODE LAT LPC LPS MA M PC MPS LEAVING AIR TEMPERATURE LOW PRESSURE CONDENSATE LOW PRESSURE STEAM MIXED AIR MEDIUM PRESSURE CONDENSATE MEDIUM PRESSURE STEAM NPSH NET POSITIVE SUCTION HEAD OA OUTSIDE AIR OAT OUTSIDE AIR TEMPERATURE ODP OPEN DRIPPROOF OSA OUTSIDE AIR OV OUTLET VELOCITY PF PREFILTER PHC PREHEAT COIL RL RS RHC RH RA RF RG S SFD SP SD SA SF SG SR STM REFRIGERANT LIQUID REFRIGERANT SUCTION (GAS) REHEAT COIL RELATIVE HUMIDITY RETURN AIR RETURN FAN RETURN GRILLE SUPPLY SMOKE/FIRE DAMPER STATIC PRESSURE SMOKE DAMPER; SUPPLY DIFFUSER SUPPLY AIR; SOUND ATTENUATOR SUPPLY FAN SUPPLY GRILLE SUPPLY REGISTER STEAM T, TSTAT THERMOSTAT TEFC TOTALLY ENCLOSED, FAN COOLED TG TRANSFER GRILLE UMC UH UV UNIFORM MECHANICAL CODE UNIT HEATER UNIT VENTILATOR VAV VARIABLE AIR VOLUME VSD VARIABLE SPEED DRIVE VENT VENTILATE; VENTILATION VD VOLUME DAMPER WG WALL GRILLE; WATER GAGE WSEC WASHINGTON STATE ENERGY CODE WSNEC WASHINGTON STATE NON—RESIDENTIAL ENERGY CODE WB WET BULB TEMPERATURE(°F) PLUMBING ABBREVIATIONS ACID WASTE AIR, COMPRESSED AIR BOTTOM OF PIPE CAST IRON CHEMICAL FEED CIRCULATING CITY WATER; DOMESTIC COLD WATER CLEAN OUT COMPRESSED AIR DEIONIZED WATER DISTILLED WATER DOMESTIC DOOR; DRAIN DRINKING FOUNTAIN EMERGENCY SHOWER FLOOR CLEAN OUT FLOOR DRAIN FUEL OIL RETURN FUEL OIL SUPPLY FUEL OIL VENT FREEZE PROOF HOSE BIBB GAS GALLONS PER HOUR HOSE BIBB DOMESTIC HOT WATER DOMESTIC HOT WATER CIRCULATING INTERNATIONAL PLUMBING CODE INDIRECT WASTE JANITOR L MV NPW NO N 0 PC PLBG PNEU PRV RWL RECIRC RD S SS SD UPC V VA VAC VB VTR W WC WFS t13oi7 LAVATORY MEDICAL VACUUM NON—POTABLE WATER NITROUS OXIDE; NUMBER NITROGEN OXYGEN PUMPED CONDENSATE PLUMBING PNEUMATIC PRESSURE REDUCING RAIN WATER LEADER RECIRCULATING ROOF DRAIN VAL1 REVIEWED FOR LCODE COMPLIANCE APPROVED SOIL SANITARY SEWER; SERVICE SINK; STAINLESS STEEL STORM DRAIN IJUN132013 City of Tukwila BUILDING DIVISION UNIFORM PLUMBING CODE VENT VALVE VACUUM VACUUM BREAKER VENT THRU ROOF RECEIVED CITY OF TUKWILA JUN 062013 PERMIT CENTER WASTE; WATER; WIDE(DIM) WATER CLOSET WATER FLOW SWITCH WYE • FSi consulting engineers Seattle, Washington Solutions & Se, vic LEGEND AND ABBREVIATIONS APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14-02 THOMPSON, WA CURRENT REVISION 15796 SHEET JOB NO. SYMBOL M1 DATE A .12 COMP NO. DWG NO. 14-02—M1 &I— ASPHALT RAM r S `}Xx3 .6 01) c CONN .`'��1j�TT RAL GAS M TERING'SYSTEM IRE HOSE CONN. 3'-0" ABOVE GROUND HOSE BIBB 3'-0" OFF GROUND 3/4"CW 3/4"CA Ut6 i-; A]8x 2 0 ...I..YE' - 1 "CW CO CAL-3 PIA IF - L w H.W. SYSTEM MAKE—UP, UNIT P-1� COMBUS FLOW S MODEL ION CUT—OFF ITCH—McDONNEL —2 MODEL E-2 PRESSURE EGU STRAINER PLUG VALV 4" NAT. GA FF ' pea 8" -- V!" iir_ `i 0 LE "GV ER 4" , ,T. 1 " •�� �w• 10" 150' NN NH MODEL E-2 PRESSURE EGU STRAINER PLUG VALV 4" NAT. GA FF ' pea 8" -- V!" iir_ `i 0 LE "GV ER 4" , ,T. 1 " — T RCVR 2"FUNNEL DRAIN 1 1/2" COOLER DRAIN 1/2" CONDENSATE DRAIN 2"CW VALVE 1'-6"CA (NEW) AD -1 (NEW) RF -1 AIR COMPRESSOR 6"CA (NEW, 2"IFCR (NEW) 2"IFCS (NEW) 3/4"DW IN 3/4"DW OUT G) 1/2" TO FLOOR DRAIN (NEW) ROLDITROL AIR RELEAS FITTING 6" BOILER RELIEF DR 10" PLUd VALV ANCHOR 10"-150' HWS CONN ON HW GEN 1" SOL. VALVE (N.0.) 120V 60HZ 1 1/2"CW (IN CRANE #998 1/2 'Y' STRAINER 2" AIR INTAKE, UP THRU EXIST. ROOF ER CO01 FR (FXST) EMERGENCY GENERATOR DIESEL ENGINE EXHAUST 5" SCHED 40 EXHAUST UP THRU EXIST. ROI' PENETRATION NO. COM (EXI',T.) PLUG VALVE AIR RECEIVER WITH VALVES & GAGE FURNISHED BY I.R. 30" STACK THRU ROOF 1 1 /2"CA 011 U d3oo(i)C) 10 GAL. DAY TANK '6"GA LA 2—SEPARABLE SOCKETS FOR RESISTANCE BULBS THERMOMETERS (FURNISHED WITH BTU METER INSTRUMENTATION) 2"HWR TRERICE, 9t, NO. 1325403 1/2 THERMOMETER W/ SEPERABLE SOCKET RANGE — 30' — 300'F IN RISER 1 SEPARA LE SOCKET FOR RESISTANCE BULB THERMOM R (FURNISHED WITH BTU METER INSTRUMEN ATION) 2 1/2"CA 21"HWS 2"CW 6"CA (NEW) 2"IFCR (NEW) 2"IFCS (NEW) CONN. 6" AIR TO EXIST. 6" PLANT AIR AT FLANGE REMOVAL VI 13N C)"will REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE CAD CONVERSION 14-02 BOILER REPLACE CADDNW 09.04.98 15796 FSi 12.21.12 Q� BOE/NG' o� 12.21.12 SL NED ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN DATE CHECKED REVIEWED FOR `CODE COMPLIANCE APPROVED IJUN 132013 City of Tukwila BUILDING DIVISION LEGE\D GES HAL CTES EFEE\CE liRAWI \GS SEE TIF FILE 114-002-4001 M3 FOR MYLAR DRAWING EMCVAL \OTES REMOVE BOILER 1 AND BOILER 2. BOILER JACKET WILL BE ABATED BY BOEING EH&S PRIOR TO REMOVAL COORDINATE WITH BOEING CONSTRUCTION MANAGER. REMOVE EXISTING HWS PIPING AND VALVES FROM BOILERS BACK TO INDICATED DROP. REMOVE ALL ABOVE GROUND FUEL OIL PIPING. DRAIN AND CAP FOR ABANDONMENT OF UNDERGROUND FUEL PIPING. REMOVE PUMP 1 AND 2, AND ASSOCIATED SUCTION AND DISCHARGE PIPING TO LOCATIONS SHOWN. RETAIN PUMPS AND RETURN TO BOEING. CONTACT BOEING CM FOR DIRECTIONS. REMOVE COMPRESSION TANK AND ASSOCIATED NITROGEN PIPING. REMOVE NITROGEN TANKS AND RETURN TO BOEING. REMOVE HWR PIPING BACK TO INDICATED POINT. REMOVE 6" BOILER RELIEF DRAIN PIPING BACK TO TEE. CAP UNUSED BRANCH. REMOVE 4" NATURAL GAS PIPING TO TEE AND CAP UNUSED BRANCH REMOVE 4" NATURAL GAS PIPING, STRAINER AND PLUG VALVE BACK TO ELBOW. REMOVE PIPING FROM COMPRESSION TANK TO AIR SEPARATOR, CAP AT TEE ABOVE AIR SEPARATOR. AIR RELEASE VALVE TO REMAIN. REMOVE PIPING FROM COMPRESSION TANK TO HW SYSTEM MAKE UP UNIT. REMOVE 30" EXHAUST STACK AND CAP CURB OPENING AT ROOF. SEE ARCH FOR CURB CAP ABOVE. REMOVE SEAL WATER PIPING FROM PUMP BACK TO MAKEUP WATER LIVE MAIN AND CAP TEE. 14> DISCONNECT AND RETAIN POT FEEDER FOR REINSTALLATION. REMOVE LADDER, PLATFORM AND ASSOCIATED STRUCTURAL COMPONENTS. LOCATED ABOVE BOILERS. 16 REMOVE FUEL OIL PUMP CONCRETE PADS & PATCH FLOOR. REMOVE CONCRETE PUMP PADS FOR HHW PUMP 1 AND 2 & PATCH FLOOR REMOVE FUEL OIL TRENCH COVER PLATES WITH UN—USED CUTOUTS FOR FUEL OIL 19 REMOVE STACK AND RETAIN PENETRATION FOR REUSE RECEIVED CITY OF TUKWILA JUN 0,62013 PERMIT CENTER SUBTITLE ISSUED FOR CONSTRUCTION HVAC PIPING PLAN J APPROVED BY DEPT. DATE ENCINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14-02 COL. A—E/1-4 THOMPSON, WA III• FSi consulting engineers Seattle, Washington Solutions & Service CURRENT REVISION 15796 SHEET JOB NO. DWG NO. SYMBOL IM6OR A DATE C 12.21.12 NO. 14-002-1M6OR CU ASPHAL._.F RAMP TS 3x3x3/1 6 TY' FREEZE PROTECTION UNIT HEATER. ON SETPOINT SET FOR 40T. SEE 3/M502 FOR COIL CONNECTION DETAIL 8" SEE INST DOOR LOUVER SEE ARCH GAS METERS CONN. TO NATURAL GAS METERING SYSTEM TIRE HOSE CONN. 3'-0" ABOVE GROUND HOSE BIBB 3'-0" OFF GROUND 3/4"CW -3/4"CA FOR HEATING WATER BOILER DIAGRAM SEE 1 M60 BOILER CONTROL PAN (E) OUTSIDE AIR LOUVERS, 144" * 10", TYP EMERGENCY BOILER CONNECTION H.W. SYSTE MAKE-UP, U P-1 3/4" HWS&R 1M60 M50 EXPANSION TANK ET -1 1" H.W. PUMP P-1 1M60 M502 VFD PLACEME H.WTIPUMP P-2 H.W. PUMP P-2 2"FUNNEL DRAIN 1 1/2" COOLER DRAIN 1/2" CONDENSATE DRAIN 2 CW VALVE 1'-6"CA (NEW) AIR COMPRESSOR 1/2" NPW 4" .D. AIR SI PARATOR AIR RLEASE VALVE HWS HWR 6" BOILER RELIEF DRAIN 8" 1" SOL. VALVE (N.O.) 120V 6OHZ 1 1/2"CW (IN CRANE #998 1/2 'Y' STRAINER 2" AIR INTAKE, UP THRU EXIST. ROOF AFTER C001 FR (FXIST) EMERGENCY GENERATOR DIESEL ENGINE EXHAUST 5" SCHED 40 EXHAUST UP THRU EXIST. ROS PENETRATION 28" STACK THRU ROOF NO. COM (EXI T.) AIR RECEIVER WITH VALVES & GAGE FURNISHED BY I.R. IS " 1 1/2"CA ANCHOR 10 GAL. DAY TANK SYM REVISION BY APPROVED DATE SYM 2-SEPARA:LE SOCKETS FOR RESISTANCE BULBS THERMOM RS 2"HWR TRERICE, 9t, NO. 1325403 1/2 THERMOMETER W/ SEPERABLE SOCKET RANGE - 30' - 300T IN RISER 1 SEPARABLE SOCKET FOR RESISTANCE BULB THERMOMETER REVISION 6"CA FREEZE PROTECTION UNIT HEATER. ON SETPOINT SET FOR 40'F. SEE 3/M502 FOR COIL CONNECTION DETAIL 2 1/2"CA BY APPROVED DATE A B CAD CONVERSION 14-02 BOILER REPLACEMENT PERMIT REVISIONS 15796 15796 CADDNW FSi FSi 09.04.98 12.21.12 06.03.13 CONN. 6" AIR TO EXIST. 6" PLANT AIR AT FLANGE ,22,.,2 SWIM 2"IFCR (NEW) 2"IFCS (NEW) "0-7 SEE 2/S501 FOR EQUIPMENT ANCHORING DETAIL. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN I, REVIEWED FOR 'CODE COMPLIANCE APPROVED !JUN 13 2013 Y City of Tukwila BUILDING DIVISION DATE CHECKED SUBTITLE RECEIVED CITY OF TUKWILA JUN 0..6 2013 PERMIT CENTER 'EFFE\CE NAWI\GS SEE TIF FILE 114-002-4001 M3 FOR MYLAR DRAWING CO\S-RUCTIO\ \OTES PROVIDE AND INSTALL BOILERS ON THE EQUIPMENT PADS. MAINTAIN MFR'S RECOMMENDED ACCESS CLEARANCES AS INDICATED ON BOILER 1. PROVIDE BOILER HOT WATER PIPING, VALVES AND COMBUSTION CUT OFF FLOW SWITCHES ROUTED FROM EXISTING HOT WATER LINE TO BOILERS. SEE 2/M502 FOR VALVES AND ACCESSORIES (NOT USED) PROVIDE HEATING WATER PUMPS, PROVIDE 48" BETWEEN PUMPS AND VFDs. SEE 1/M502 FOR DETAIL. FOR VFDS SEE DRAWING 1E110. PROVIDE NATURAL GAS LINE WITH VALVE TRAIN TO THE THREE BOILERS, SEE BOILER CONNECTION DETAIL 2/M502. PROVIDE EXPANSION TANK, PIPING TO PUMP INLET LINE AND APPROPRIATE FITTINGS. PROVIDE SUCTION DIFFUSERS FOR THE PUMP INLETS, CHECK VALVES, SHUT OFF VALVES AND APPROPRIATE CONNECTIONS. SEE 1/M502 FOR PUMP CONNECTION DETAIL. PROVIDE FLUE AND CONNECT TO EACH BOILER, ROUTE FLUE UP THROUGH EXISTING 30" ROOF PENETRATION. SEE A/M502. 4> PROVIDE, MOUNT BOILER CONTROL PANELS ON STRUT SUPPORT AT END OF EQUIPMENT PAD. 1> CONNECT 2" BOILER RELIEF DRAIN TO BOILER RELIEF VALVE OUTLET & ROUTE TO EXISTING DRAIN PIPING. SLOPE HORIZONTAL PIPING DN TO DRAIN. PROVIDE PIPE CONNECTION FROM H.W. SYSTEM MAKE—UP UNIT TO EXPANSION TANK PROVIDE EMERGENCY BOILER CONNECTION, VALVE AND 10" FLANGE, AND BLIND FLANGE. jE> PROVIDE SIMILAR TO EXISTING STEEL PLATE TRENCH COVER. MOUNT RELOCATED POT FEEDER. PROVIDE NEW GAS REGULATORS. VENTING THROUGH EXISTING ROOF PENETRATIONS. 16 PROVIDE PUMP PADS, SEE DETAIL 1/M502 PROVIDE VERTICALLY MOUNTED SEISMIC SHUTOFF VALVE PER MANUFACTURER INSTALLATION INSTRUCTIONS. i�j� PROVIDE FLUE TEMPERATURE GAGE AT EACH BOILER FLUE. 1> PROVIDE UNIT HEATER, ROUTE HEATING WATER PIPING AS SHOWN, CONNECT TO EXISTING HWS/R. PROVIDE J.L.WINGERT CO. COUPON RACK CSCR -5-007, WITH ASSOCIATED CONNECTION PIPE AND VALVES. PROVIDE UNISTRUT MOUNTING. PROVIDE J.L.WINGERT CO SAMPLE COOLER SC-2—B—COP, AND ASSOCIATED CONNECTION PIPE AND ISOLATION VALVES. CONNECT WITH i" PIPING. PROVIDE UNISTRUT MOUNTING. MODIFY 30" STACK PENETRATION FOR 28" FLUE. SEE S501 FOR LOUVER WALL OPENING AND REINFORCING. PROVIDE FLANGES FOR FUTURE 48" PIPE SPOOL FOR CROSSOVER CONNECTION, PROVIDE BLIND FLANGES, TYP 2. PROVIDE 36" X 14" DUCT FROM TOP OF EXISTING LOUVERS AT A MAXIMUM OF 45.0° ANGLE TO WITHIN 8" OF CEILING, REFER TO SECTION B/M502. 1 ISSUED FOR CONSTRUCTION HVAC PIPING PLAN • FSi consulting engineers Seattle, Washington Solutions (Sc Service CURRENT REVISION 15796 SYMBOL DATE A 06.03.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14-02 COL. A—E/1-4 THOMPSON, WA SHEET 1M60 JOB NO. COMP NO. DWG NO. 14-002-1M60 /-8;\ EMERGENCY BOILER CONNECTION -45 - 1 - 4' BENCH 8" NAT. GAS 3 TYP 1 M61:1114502 is" 4"GV PLUG VALVE TYP 4 - STRAINER 1 1/2" AIR TO RCVR - 2"FUNNEL DRAIN 1 1/2" COOLER DRAIN 1/2" CONDENSATE DRAIN 2 CW VALVE 1'-6"CA (NEW) AIR COMPRESSOR 1/2" NPW 4" .D. AIR SI PARATOR AIR RLEASE VALVE HWS HWR 6" BOILER RELIEF DRAIN 8" 1" SOL. VALVE (N.O.) 120V 6OHZ 1 1/2"CW (IN CRANE #998 1/2 'Y' STRAINER 2" AIR INTAKE, UP THRU EXIST. ROOF AFTER C001 FR (FXIST) EMERGENCY GENERATOR DIESEL ENGINE EXHAUST 5" SCHED 40 EXHAUST UP THRU EXIST. ROS PENETRATION 28" STACK THRU ROOF NO. COM (EXI T.) AIR RECEIVER WITH VALVES & GAGE FURNISHED BY I.R. IS " 1 1/2"CA ANCHOR 10 GAL. DAY TANK SYM REVISION BY APPROVED DATE SYM 2-SEPARA:LE SOCKETS FOR RESISTANCE BULBS THERMOM RS 2"HWR TRERICE, 9t, NO. 1325403 1/2 THERMOMETER W/ SEPERABLE SOCKET RANGE - 30' - 300T IN RISER 1 SEPARABLE SOCKET FOR RESISTANCE BULB THERMOMETER REVISION 6"CA FREEZE PROTECTION UNIT HEATER. ON SETPOINT SET FOR 40'F. SEE 3/M502 FOR COIL CONNECTION DETAIL 2 1/2"CA BY APPROVED DATE A B CAD CONVERSION 14-02 BOILER REPLACEMENT PERMIT REVISIONS 15796 15796 CADDNW FSi FSi 09.04.98 12.21.12 06.03.13 CONN. 6" AIR TO EXIST. 6" PLANT AIR AT FLANGE ,22,.,2 SWIM 2"IFCR (NEW) 2"IFCS (NEW) "0-7 SEE 2/S501 FOR EQUIPMENT ANCHORING DETAIL. ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN I, REVIEWED FOR 'CODE COMPLIANCE APPROVED !JUN 13 2013 Y City of Tukwila BUILDING DIVISION DATE CHECKED SUBTITLE RECEIVED CITY OF TUKWILA JUN 0..6 2013 PERMIT CENTER 'EFFE\CE NAWI\GS SEE TIF FILE 114-002-4001 M3 FOR MYLAR DRAWING CO\S-RUCTIO\ \OTES PROVIDE AND INSTALL BOILERS ON THE EQUIPMENT PADS. MAINTAIN MFR'S RECOMMENDED ACCESS CLEARANCES AS INDICATED ON BOILER 1. PROVIDE BOILER HOT WATER PIPING, VALVES AND COMBUSTION CUT OFF FLOW SWITCHES ROUTED FROM EXISTING HOT WATER LINE TO BOILERS. SEE 2/M502 FOR VALVES AND ACCESSORIES (NOT USED) PROVIDE HEATING WATER PUMPS, PROVIDE 48" BETWEEN PUMPS AND VFDs. SEE 1/M502 FOR DETAIL. FOR VFDS SEE DRAWING 1E110. PROVIDE NATURAL GAS LINE WITH VALVE TRAIN TO THE THREE BOILERS, SEE BOILER CONNECTION DETAIL 2/M502. PROVIDE EXPANSION TANK, PIPING TO PUMP INLET LINE AND APPROPRIATE FITTINGS. PROVIDE SUCTION DIFFUSERS FOR THE PUMP INLETS, CHECK VALVES, SHUT OFF VALVES AND APPROPRIATE CONNECTIONS. SEE 1/M502 FOR PUMP CONNECTION DETAIL. PROVIDE FLUE AND CONNECT TO EACH BOILER, ROUTE FLUE UP THROUGH EXISTING 30" ROOF PENETRATION. SEE A/M502. 4> PROVIDE, MOUNT BOILER CONTROL PANELS ON STRUT SUPPORT AT END OF EQUIPMENT PAD. 1> CONNECT 2" BOILER RELIEF DRAIN TO BOILER RELIEF VALVE OUTLET & ROUTE TO EXISTING DRAIN PIPING. SLOPE HORIZONTAL PIPING DN TO DRAIN. PROVIDE PIPE CONNECTION FROM H.W. SYSTEM MAKE—UP UNIT TO EXPANSION TANK PROVIDE EMERGENCY BOILER CONNECTION, VALVE AND 10" FLANGE, AND BLIND FLANGE. jE> PROVIDE SIMILAR TO EXISTING STEEL PLATE TRENCH COVER. MOUNT RELOCATED POT FEEDER. PROVIDE NEW GAS REGULATORS. VENTING THROUGH EXISTING ROOF PENETRATIONS. 16 PROVIDE PUMP PADS, SEE DETAIL 1/M502 PROVIDE VERTICALLY MOUNTED SEISMIC SHUTOFF VALVE PER MANUFACTURER INSTALLATION INSTRUCTIONS. i�j� PROVIDE FLUE TEMPERATURE GAGE AT EACH BOILER FLUE. 1> PROVIDE UNIT HEATER, ROUTE HEATING WATER PIPING AS SHOWN, CONNECT TO EXISTING HWS/R. PROVIDE J.L.WINGERT CO. COUPON RACK CSCR -5-007, WITH ASSOCIATED CONNECTION PIPE AND VALVES. PROVIDE UNISTRUT MOUNTING. PROVIDE J.L.WINGERT CO SAMPLE COOLER SC-2—B—COP, AND ASSOCIATED CONNECTION PIPE AND ISOLATION VALVES. CONNECT WITH i" PIPING. PROVIDE UNISTRUT MOUNTING. MODIFY 30" STACK PENETRATION FOR 28" FLUE. SEE S501 FOR LOUVER WALL OPENING AND REINFORCING. PROVIDE FLANGES FOR FUTURE 48" PIPE SPOOL FOR CROSSOVER CONNECTION, PROVIDE BLIND FLANGES, TYP 2. PROVIDE 36" X 14" DUCT FROM TOP OF EXISTING LOUVERS AT A MAXIMUM OF 45.0° ANGLE TO WITHIN 8" OF CEILING, REFER TO SECTION B/M502. 1 ISSUED FOR CONSTRUCTION HVAC PIPING PLAN • FSi consulting engineers Seattle, Washington Solutions (Sc Service CURRENT REVISION 15796 SYMBOL DATE A 06.03.13 APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14-02 COL. A—E/1-4 THOMPSON, WA SHEET 1M60 JOB NO. COMP NO. DWG NO. 14-002-1M60 301LE goo v BOILER E -STOP PUSHBUTTON TYP 2. SEE ELECTRICAL FUTURE BOILER PUMP FOR VARIABLE FLOW, TYP. 3 FUTURE CROSSOVER FOR VARIABLE FLOW ATER TREAT CHEM FEEDER HWS TO 14-01 A HEATI\ J WATE 3O I LES 7 IAG SAM M501 SCALE: NONE HWR FROM 14-01 BOILER CONTROL 1. BOILER OPERATION AND SEQUENCEING SHALL BE CONTROLLED BY THE BOILER CONTROL PANEL, INCLUDING SAFETIES AND INTERLOCKS. 2. EMCS SHALL ENABLE BOILERS ON SCHEDULE. 3. ONE SET BOILER ISOLATION VALVES SHALL OPEN WHEN SYSTEM ENABLED. 4. SECOND SET BOILER ISOLATION VALVES SHALL OPEN WHEN CALL FDR SECOND BOILER ON 5. BOILER CONTROL SHALL PROVE BOILER WATER FLOW PRIOR TO FIRING BOILER. 6. BOILERS SHALL BE CONTROLLED TO MAINTAIN HEATING WATER SUPPLY TEMPERATURE SETPOINT (INITIALLY 180°F), WITH AN ADJUSTABLE DEADBAND (INITIALLY 4°F). 7. STAGE BOILERS ACOORDING TO MANUFACTURER'S RECOMMENDATIONS AND BOILER CONTROL PANEL ON -BOARD SEQUENCES. 8. THE BOILER CONTROL PANEL SHALL DESIGNATE ONE BOILER AS THE LEAD, WITH THE NEXT AS LAG. THE THIRD BOILER IS STANDBY/BACKUP. WHEN THE LEAD BOILER HAS 300 RUN HOURS TIME LOGGED, THE BOILER CONTROL PANEL SHALL DESIGNATE THE NEXT BOILER AS LEAD. ALL THREE UNITS SHALL BE ROTATED EQUALLY THROUGH THE LEAD DESIGNATION. SAFETIES 1. WHEN A LEAD OR LAG BOILER FAILS TO OPERATE, START STANDBY BOILER AND PROVIDE BOILER FAILURE SIGNAL TO EMCS. 2. EMERGENCY PUSHBUTTONS SHALL BE HARDWIRED TO DISABLE BOILERS BY CUTTING POWER TO BURNER CONTROLS. NOTES 1. DESIGN IS FOR DUAL FLOW SYSTEM AND CONSTANT TEMP SETPOINT. 2. SYSTEM HAS PROVISIONS FOR FUTURE VARIABLE FLOW OPERATION. VARIABLE FLOW OPERATION OF THESE BOILERS WILL REQUIRE ADDITION OF BOILER CIRCULATION PUMPS, AND PIPING AND CONTROLS MODIFICATIONS. 3. BOILER CONTROL PANEL SHALL HAVE PROVISION FOR FUTURE HWST RESET. HEATING WATER PUMPS CONTROL 1. ONE SET BOILER ISOLATION VALVES SHALL OPEN WHEN SYSTEM ENABLED. 2. ONE PUMP SHALL START WHEN SYSTEM IS ENABLED. 3. WHEN THERE IS A CALL FOR A SECOND BOILER, SECOND PUMP SHALL START. 4. THE EMCS CONTROL PANEL SHALL DESIGNATE ONE PUMP AS THE LEAD, WITH THE NEXT AS LAG. THE THIRD PUMP IS STANDBY/BACKUP. WHEN THE LEAD PUMP HAS 300 RUN HOURS TIME LOGGED, THE EMCS CONTROL PANEL SHALL DESIGNATE THE NEXT PUMP AS LEAD. ALL THREE PUMPS SHALL BE ROTATED EQUALLY THROUGH THE LEAD DESIGNATION. SAFETIES 5. WHEN A LEAD OR LAG PUMP FAILS TO PROVE OPERATION, START STANDBY PUMP AND PROVIDE PUMP FAILURE SIGNAL TO EMCS. NOTES 1. VFD SPEED SETTING FOR ALL THREE PUMPS SHALL BE BALANCED TO THE DESIGN PUMP FLOW. 2. DESIGN IS FOR A DUAL FLOW SYSTEM WITH ONE PUMP ON PROVIDING 400 GPM AND TWO PUMPS ON PROVIDING 800 GPM. 3. SYSTEM HAS PROVISIONS FOR FUTURE VARIABLE FLOW OPERATION. VARIABLE FLOW OPERATION WILL REQUIRE PIPING AND CONTROL SEQUENCE MODIFICATIONS. EMCS CONTROL 1. SYSTEM ENABLE/DISABLE 2. SUPPLY WATER TEMPERATURE SETPOINT 3. BOILER ON/OFF DEADBAND MONITORING 1. BOILER FAULTS 2. PUMP FAILURE 3. SUPPLY WATER TEMPERATURE 4. RETURN WATER TEMPERATURE NOTES 1. SEE POINT LIST HEATI\ G WATE SEQUE\CES OF OPHATIO\ SCALE: NONE P 3OILE PLA\T CHCS POI\T SU V VARY SYSTEM NAME: HW HEATING SYSTEM DESCRIPTION: LIQUID TEMP T ANALOG INPUTS ANALOG OUTPUTS DIGITAL INPUTS DIGITAL OUTPUTS ALARMS REMARKS 180 HYDRONIC BOILER ENABLE 10 PROVIDE VFD (SEE ELECTRICAL), SUCTION DIFFUSER P-2 1 180 50 BOILER STATUS 10 PROVIDE VFD (SEE ELECTRICAL), SUCTION DIFFUSER 1 PRIMARY HEATING WATER CIRCULATION 1 50 HW PUMP 1 START/STOP 10 PROVIDE VFD (SEE ELLECTRICAL), SUCTION DIFFUSER 18 1 CLEAVER BROOKS FLX 500 HW PUMP 1 STATUS 1 4000 1 CURRENT SENSING RELAY HW PUMP 2 START/STOP 180 85% ET 2.03 1 GAS 5,000 HW PUMP 2 STATUS 2 CLEAVER BROOKS FLX 500 1 1 CURRENT SENSING RELAY HW BOILER PUMP 3 START/STOP 4000 WT 406 1 180 85% ET HW BOILER PUMP 3 STATUS 160 GAS 1 18 1 CURRENT SENSING RELAY BOILER SUPPLY TEMP 1 1 BOILER RETURN TEMP 1 1 TOTALS: 2 0 4 4 6 BOILER CONTROL 1. BOILER OPERATION AND SEQUENCEING SHALL BE CONTROLLED BY THE BOILER CONTROL PANEL, INCLUDING SAFETIES AND INTERLOCKS. 2. EMCS SHALL ENABLE BOILERS ON SCHEDULE. 3. ONE SET BOILER ISOLATION VALVES SHALL OPEN WHEN SYSTEM ENABLED. 4. SECOND SET BOILER ISOLATION VALVES SHALL OPEN WHEN CALL FDR SECOND BOILER ON 5. BOILER CONTROL SHALL PROVE BOILER WATER FLOW PRIOR TO FIRING BOILER. 6. BOILERS SHALL BE CONTROLLED TO MAINTAIN HEATING WATER SUPPLY TEMPERATURE SETPOINT (INITIALLY 180°F), WITH AN ADJUSTABLE DEADBAND (INITIALLY 4°F). 7. STAGE BOILERS ACOORDING TO MANUFACTURER'S RECOMMENDATIONS AND BOILER CONTROL PANEL ON -BOARD SEQUENCES. 8. THE BOILER CONTROL PANEL SHALL DESIGNATE ONE BOILER AS THE LEAD, WITH THE NEXT AS LAG. THE THIRD BOILER IS STANDBY/BACKUP. WHEN THE LEAD BOILER HAS 300 RUN HOURS TIME LOGGED, THE BOILER CONTROL PANEL SHALL DESIGNATE THE NEXT BOILER AS LEAD. ALL THREE UNITS SHALL BE ROTATED EQUALLY THROUGH THE LEAD DESIGNATION. SAFETIES 1. WHEN A LEAD OR LAG BOILER FAILS TO OPERATE, START STANDBY BOILER AND PROVIDE BOILER FAILURE SIGNAL TO EMCS. 2. EMERGENCY PUSHBUTTONS SHALL BE HARDWIRED TO DISABLE BOILERS BY CUTTING POWER TO BURNER CONTROLS. NOTES 1. DESIGN IS FOR DUAL FLOW SYSTEM AND CONSTANT TEMP SETPOINT. 2. SYSTEM HAS PROVISIONS FOR FUTURE VARIABLE FLOW OPERATION. VARIABLE FLOW OPERATION OF THESE BOILERS WILL REQUIRE ADDITION OF BOILER CIRCULATION PUMPS, AND PIPING AND CONTROLS MODIFICATIONS. 3. BOILER CONTROL PANEL SHALL HAVE PROVISION FOR FUTURE HWST RESET. HEATING WATER PUMPS CONTROL 1. ONE SET BOILER ISOLATION VALVES SHALL OPEN WHEN SYSTEM ENABLED. 2. ONE PUMP SHALL START WHEN SYSTEM IS ENABLED. 3. WHEN THERE IS A CALL FOR A SECOND BOILER, SECOND PUMP SHALL START. 4. THE EMCS CONTROL PANEL SHALL DESIGNATE ONE PUMP AS THE LEAD, WITH THE NEXT AS LAG. THE THIRD PUMP IS STANDBY/BACKUP. WHEN THE LEAD PUMP HAS 300 RUN HOURS TIME LOGGED, THE EMCS CONTROL PANEL SHALL DESIGNATE THE NEXT PUMP AS LEAD. ALL THREE PUMPS SHALL BE ROTATED EQUALLY THROUGH THE LEAD DESIGNATION. SAFETIES 5. WHEN A LEAD OR LAG PUMP FAILS TO PROVE OPERATION, START STANDBY PUMP AND PROVIDE PUMP FAILURE SIGNAL TO EMCS. NOTES 1. VFD SPEED SETTING FOR ALL THREE PUMPS SHALL BE BALANCED TO THE DESIGN PUMP FLOW. 2. DESIGN IS FOR A DUAL FLOW SYSTEM WITH ONE PUMP ON PROVIDING 400 GPM AND TWO PUMPS ON PROVIDING 800 GPM. 3. SYSTEM HAS PROVISIONS FOR FUTURE VARIABLE FLOW OPERATION. VARIABLE FLOW OPERATION WILL REQUIRE PIPING AND CONTROL SEQUENCE MODIFICATIONS. EMCS CONTROL 1. SYSTEM ENABLE/DISABLE 2. SUPPLY WATER TEMPERATURE SETPOINT 3. BOILER ON/OFF DEADBAND MONITORING 1. BOILER FAULTS 2. PUMP FAILURE 3. SUPPLY WATER TEMPERATURE 4. RETURN WATER TEMPERATURE NOTES 1. SEE POINT LIST HEATI\ G WATE SEQUE\CES OF OPHATIO\ SCALE: NONE P v D CH SERVICE L= MARK NO. SERVICE LIQUID TEMP T HEAD (FT. H20) GPM HP REMARKS P-1 PRIMARY HEATING WATER CIRCULATION 180 50 400 10 PROVIDE VFD (SEE ELECTRICAL), SUCTION DIFFUSER P-2 PRIMARY HEATING WATER CIRCULATION 180 50 400 10 PROVIDE VFD (SEE ELECTRICAL), SUCTION DIFFUSER P-3 PRIMARY HEATING WATER CIRCULATION 180 50 400 10 PROVIDE VFD (SEE ELLECTRICAL), SUCTION DIFFUSER 18 2 CLEAVER BROOKS FLX 500 B2 4000 WT 406 160 180 85% ET TA\ < SCHEDULE MARK NO. SERVICE GALLONS SIZE PRESSURE REMARKS T-1 FUEL OIL STORAGE 20,000 UH -1 - - ATMOSPHERE 24 T-2 HOT WATER SYSTEM EXPANSION TANK 317 98"x36" MAX. 125 PSI MINIMUM ACCEPTANCE: 0.50 BASIS OF DESIGN: BELL & GOSSETT WTA-457 3500 1 18" 4490 1/2 BELT DRIVE U\ IT HEATED SCHEDULE MA:K NO SERVICE CAPACITY HHW TEMP ° GPM FAN FAN HP VOLT/PH REMARKS UH -1 - - BOILER ROOM FREEZE PROTECTION - - - - - - - 24 20 2.5 580 1/20 120/1 - BASIS OF DESIGN: TRANE UHS-A25 PROVIDE WITH INTEGRAL THERMOSTAT j POWER GOOF EXHAUSTES MARK NO. SERVICE CFM STATIC PRESSURE IN WG. MIN. WHEEL DIA. MAX. TIP SPEED FPM MOTOR HP REMARKS RF -1 SUMMERTIME HEAT REMOVAL 3500 1/8 18" 4490 1/2 BELT DRIVE RF -2 SUMMERTIME HEAT REMOVAL 3500 1/8 18" 4490 1/2 BELT DRIVE REVIEWED FOR CODE COMPLIANCE APPROVED I JUN 13 2013 RECEIVED CITY OF TUKWILA JUN 0,6 2013 PERMIT CENTER (3.Nta. 7 7 ISSUED FOR CONSTRUCTION FSi consulting engineers Seattle, Washington Solutions 8c Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A 14-02 BOILER REPLACEMENT 15796 FSi 12.21.12 12.21.12 &ORD ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN A.RUBECK DATE CHECKED SUBTITLE HEATING WATER DIAGRAM AND SCHEDULES APPROVED BY DEPT. DATE ENGINEER A.RUBECK CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14-02 KENT, WA CURRENT REVISION 15796 SHEET JOB NO. DWG NO. SYMBOL A DATE 12.21.12 M501 WAS 14-02 1 ounai'11J UIIVLAUIv HEATI\G WATE 3OILE SCHEDULE MARK BOILER OUTPUT (MBH) TYPE MAX HW FLOW (GPM) INLET WATER TEMP (DEG F) OUTLET WATER TEMP (DEG F) MIN EFF WATER PRESS DROP (PSIG) PRESSURE RATING (PSIG) BURNER MAKE AND MODEL FUEL INPUT (MBH) MIN INLET PRESS (IN WG) HP B1 4000 WT 406 160 180 85% ET 2.03 160 GAS 5,000 18 2 CLEAVER BROOKS FLX 500 B2 4000 WT 406 160 180 85% ET 2.03 160 GAS 5,000 18 2 CLEAVER BROOKS FLX 500 B3 4000 WT 406 160 180 85% ET 2.03 160 GAS 5,000 18 2 CLEAVER BROOKS FLX 500 (3.Nta. 7 7 ISSUED FOR CONSTRUCTION FSi consulting engineers Seattle, Washington Solutions 8c Service SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE A 14-02 BOILER REPLACEMENT 15796 FSi 12.21.12 12.21.12 &ORD ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN A.RUBECK DATE CHECKED SUBTITLE HEATING WATER DIAGRAM AND SCHEDULES APPROVED BY DEPT. DATE ENGINEER A.RUBECK CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14-02 KENT, WA CURRENT REVISION 15796 SHEET JOB NO. DWG NO. SYMBOL A DATE 12.21.12 M501 WAS 14-02 ADJACENT BUILDING —\ 2'_O" 28" STACK RAIN CAP GAGE COCK, TYP 1/4", TYP COUPLING MOTOR HOUSEKEEPING PAD TO FILL CAPPED DRAIN VALVE Sc HOSE CONN, 2 TYP PUMP & EXPANCION TANK CONNECTION DETAIL(1� SCALE: NONE 28" (E) CURB BOILER BREECHING AND FLUE, TYP FLUE DRAIN —\ BOILER ROOM 16" DN ROOF 28" BOILER 3 16" BOILER 2 MAX 10° 16" 16" BOILER 1 BOILER FLUE SECTION (A� SCALE: 1/4" = 1'-0" 1M60 M502 GE\HAL \OTES FACTORY -BUILT, DOUBLE WALL, 304 STAINLESS STEEL, MODULAR CONNECTOR TYPE, SELKIRK METALBESTOS MODEL PS, OR EQUAL. CO\STRUCTIO\ \OYES PROVIDE FLUE STACK TERMINATION 2' ABOVE ADJACENT BUILDING. PROVIDE BAND WITH CABLE EYES. PROVIDE GUY WIRE, SIMILAR TO EXISTING, CONNECT TO EXISTING BRACKETS ON ROOF, 3 PLACES. SEE ARCH FOR CURB CAP/FLASHING TO EXISTING CURB. SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ORIG 14-02 BOILER REPLACEMENT 15796 FSi 12.21.12 A PERMIT REVISIONS 15796 FSi 06.04.13 Q� 2rivG' o'— ,2.2,.,2 SIND ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DRAWN EMCS STACK TEMP SENSOR BOILER N. TO FD —BURNER 1 M60 M502 VENT GAS TRAIN REGULATOR, PRESSURE SWITCH & ALL OTHER DEVICES REQUIRING VENTING BY ASME CSD -1. G1COORDINATE SIZE & NUMBER W/BOILER MFR. VENT THROUGH EXISTING GAS VENT OR PENETRATIONS. BOILER HOLD-DOWN BOLTS, 4 TYP TO FD DRAIN 1 1/2" * ASTERISK INDICATES ITEMS FURNISHED WITH BOILER, INSTALLED BY CONTRACTOR BOILER CONNECTION DETAIL iM60IM502 SCALE: NONE PRESSURE & TEMP TEST PORT, TYP MANUAL VENT VERIFY COIL INLET AND OUTLET CONN. LOCATIONS PRIOR TO PIPING FABRICATION AND INSTALLATION. CONNECT INLET AND OUTLET PER MANUFACTURER'S INSTRUCTIONS. 2—WAY MODULATING CONTROL VALVE MANUAL DRAIN WITH HOSE—END CONNECTION UH COIL CONNECTION DETAIL�3� SCALE: NONE r7o77 ISSUED FOR CONSTRUCTION DATE SUBTITLE CHECKED DETAILS REVIEWED FOR CODE COMPLIANCE APPROVED IJUN132013 City of Tukwila BUILDING DIVISION 1 M60 M502 RECEIVED CITY OF TUKWILA JUN 0.62013 PERMIT CENTER FSi consulting engineers Seattle, Washington Solutions & Service CURRENT REVISION SYMBOL 15796 A DATE APPROVED BY DEPT. DATE ENGINEER CHECKED APPROVED APPROVED TITLE MECHANICAL MASTER BUILDING 14-02 THOMPSON, WA SHEET M502 12.21.12 JOB NO. COMP NO. DWG NO. 14-02—M502 or 0 4-02 Boiler Replacement\_Drawinqs\ 0 CO LO 0 0 N N_ 0 v O O ci c LSH305 LSL305 LSLL305 LSHH304 M9 5HP SEWE (CLAS 1 M10 5HP 1E110 E500 100A PNL A3/32,34,36 Feed to Propane Tank Bldg. 14-05 SYM 3/4HP SUMP PUMP 1/2"C,3#12,2#14 RIGID U—GRD Compressor Cooling Tower Alarm Panel Incoming Conduit Pull Box GENERATOR CONTROL PANEL 2 1 /2"AL(3)350MCM LOAD BANK 300KW-30,480V REVISION G G 4/0 CU GROUNG WIRE (TYPICAL) BY APPROVED DATE SYM REVISION BY APPROVED DATE A 14-02 BOILER REPLACEMENT 15796 CASNE 12.21.12 0 N N Q,�BOE/NG° LOAD BANK 400AF FEEDER CB 350AT REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED P ROVED BY ONAL DEPT. DATE DRAWN L.WILLIAMS DATE 7.8.98 CHECKED SUBTITLE LEGE\ 0 Stop Button with Lockout GEVPAL \OTES 1. ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600V OR LESS, GENERATOR RADIATOR Mt3-*--T`77 120/208 277/480V "A"PHASE LEFT BUS IN PANEL) BLACK BROWN "B"PHASE CENTER BUS IN PANEL)RED ORANGE "C"PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. 6. FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7. USE #10 THWN/THHN FOR COMMON NEUTRAL CONDUCTOR IN ALL 20 AMP MULTI—BRANCH RUNS. 8. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. CO\ S-RUCTIO\ \OTES REMOVE AND DISPOSE OF EXISTING ELECTRICAL AND ANNUNCIATOR CABINET CONDUCTORS AND CONDUITS BACK TO SOURCE. REMOVE GROUND CONNECTION FROM EXISTING BOILER TO GROUND RING. REMOVE AND DISPOSE OF EXISTING FUEL OIL PUMP CONDUIT, CONDUCTORS AND ALL ASSOCIATED ELECTRICAL COMPONENTS BACK TO SOURCE. REMOVE AND DISPOSE OF EXISTING HOT WATER PUMP CONDUIT, CONDUCTORS AND ALL ASSOCIATED ELECTRICAL COMPONENTS BACK TO SOURCE. REMOVE EXISTING CONNECTION TO GROUND RING. REVIEWED FOR `:CODE COMPLIANCE APPROVED IJUN 132013 City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTION 277/480 VOLT POWER PLAN RECEIVED CITY OF TUKWILA JUN 0.62013 PERMIT CENTER CASNE ENGINEERING, INC. EELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 1231-085 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14-02 COL. A—F/1-4 THOMPSON, WA CURRENT REVISION SYMBOL DATE 15796 A 12.21.12 SHEET JOB NO. DWG NO. IEIIOR 03 M 0 COMP NO. 14-002-1E110R —MEMMEM _ STATION Ri 17-23t,2#1 2 Al PNLA3/5ab IF DIV 1 AREA INSIDE) 30'' 1/2"C,3#12 PNL.A3/4a,b,c /.' T & 8#14CNTRL i P DIS ONNECT �� II`� ,6#12PWR ® ,��� FUI L HEAT SEWER LIFT STATION . // ' >7 XF „MR 2 . , � CONTROL PANEL 24 VA VA I—R AIR ', '.a NSI / COMPRESSOR 60 HP r3/4"C3#8Air 11.0.' • " ', A �� ' 480V PNL.A3 20,22,24 : ► , Affik )(7z74/ MAKE—UP 1"C,3 12 & 3#14 ii CMOS sq _ PUMP#1 MCC5 2 - - :" 3/4 C,3#12,1 #10GND 5HP IR ,• a '' », , A I' CONTROL PANEL o ONTROL PANEL A �' T� 6 CONTROL PANEL(11a,b,c) — I �rAD-1 A.� 0, Vol//I,X - V, 10HP ill �/ iii d ' ,_,,,,,, �I'�,,' H.W. GENE"ATe- • H.W. ERATOR#1 v4 f.� . k 1-1 2"C 3 2 1 6GND 1-1 2"C 3 2 1 6GND # # # MCC5 s `�� r-3 1 y. / TO CC 5/B2 TO CC 5 I—R AIR REFER AIR ck''" DRYER 9abc 60 HP [OMPRESS07. A3/ 480V _ PNL.A3 (OLD 31 BH) / AO ��/�/. .,0 PNLA3-1 .. XFMR (Old 21BH) 4f�! // EM .' PWR` ! 350KW SUMP EMERGENCY GENERATOR 480/277V 30 4W — 60HZ PULL BOX I 2 1 /2"AL(3)350MCM PNL X4P1V����A -- CB _ _ _ T Compressor Cooling Tower Alarm Panel Incoming Conduit Pull Box GENERATOR CONTROL PANEL 2 1 /2"AL(3)350MCM LOAD BANK 300KW-30,480V REVISION G G 4/0 CU GROUNG WIRE (TYPICAL) BY APPROVED DATE SYM REVISION BY APPROVED DATE A 14-02 BOILER REPLACEMENT 15796 CASNE 12.21.12 0 N N Q,�BOE/NG° LOAD BANK 400AF FEEDER CB 350AT REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED P ROVED BY ONAL DEPT. DATE DRAWN L.WILLIAMS DATE 7.8.98 CHECKED SUBTITLE LEGE\ 0 Stop Button with Lockout GEVPAL \OTES 1. ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600V OR LESS, GENERATOR RADIATOR Mt3-*--T`77 120/208 277/480V "A"PHASE LEFT BUS IN PANEL) BLACK BROWN "B"PHASE CENTER BUS IN PANEL)RED ORANGE "C"PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. 6. FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. 7. USE #10 THWN/THHN FOR COMMON NEUTRAL CONDUCTOR IN ALL 20 AMP MULTI—BRANCH RUNS. 8. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. CO\ S-RUCTIO\ \OTES REMOVE AND DISPOSE OF EXISTING ELECTRICAL AND ANNUNCIATOR CABINET CONDUCTORS AND CONDUITS BACK TO SOURCE. REMOVE GROUND CONNECTION FROM EXISTING BOILER TO GROUND RING. REMOVE AND DISPOSE OF EXISTING FUEL OIL PUMP CONDUIT, CONDUCTORS AND ALL ASSOCIATED ELECTRICAL COMPONENTS BACK TO SOURCE. REMOVE AND DISPOSE OF EXISTING HOT WATER PUMP CONDUIT, CONDUCTORS AND ALL ASSOCIATED ELECTRICAL COMPONENTS BACK TO SOURCE. REMOVE EXISTING CONNECTION TO GROUND RING. REVIEWED FOR `:CODE COMPLIANCE APPROVED IJUN 132013 City of Tukwila BUILDING DIVISION ISSUE FOR CONSTRUCTION 277/480 VOLT POWER PLAN RECEIVED CITY OF TUKWILA JUN 0.62013 PERMIT CENTER CASNE ENGINEERING, INC. EELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 1231-085 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14-02 COL. A—F/1-4 THOMPSON, WA CURRENT REVISION SYMBOL DATE 15796 A 12.21.12 SHEET JOB NO. DWG NO. IEIIOR 03 M 0 COMP NO. 14-002-1E110R N O I 0 0 m I0 co O N CNI 0 v 0 0 ai 0 0 N N SYM ASPHALT RAMP TS 3x3x3/16 TYP SEWE/�� (CLASS LOAD BANK 300KW-30,480V REVISION GAS METERS BY APPROVED DATE SYM REVISION BY APPROVED DATE A 14-02 BOILER REPLACEMENT 15796 CASNE 12.21.12 AUSFAC, A if ® PNL X4P1 GENERATOR CONTROL PANEL LOAD BANK 400AF FEEDER CB 350AT M3�77 REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN A. TURNBULL CHECKED roiNEER CHECKED DATE 11.05.02 SUBTITLE ISSUE FOR CONSTRUCTION CMCS PLAN LECE\D FLOW SENSOR TEMPERATURE SENSOR HUMIDITY SENSOR PRESSURE SENSOR DIFFERENTIAL PRESSURE SWITCH EED SOLENOID VALVE PV ELECT CONTROLLED PNEU VALVE ELO SMOKE DETECTOR ® MOTORIZED ACTUATOR INLET VANE GUIDE MODULAR BUILDING CONTROLLER MBC EXPANSION PANEL ® CMCS CONTROLLED MOTOR STARTER TRUNK JUNCTION BOX MOTOR OPERATED VALVE AO LEVEL SENSOR/SWITCH TSP #18 TWISTED SHIELDED PAIR CABLE IG MBC EXP FIELD GE\ 107/01 POINT TERM LOCATION IN PNL 107 PRI PNL# (SCU RPU) 107101 SEC PNL# (DPU MPU) WITH ITS PRIMARY PANEL NO. ERAL \OTES 1 • ALL CONDUIT TO BE 1/2" E.M.T. UNLESS 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE 3. THE FOLLOWING COLOR CODING OF CONDUCTORS CO\ STUCTIO\ \OTES REMOVE AND DISPOSE OF EXISTING CONTROL PANEL, CONDUIT AND CONDUCTORS BACK TO SOURCE. REMOVE AND DISPOSE OF ANY CMCS CONTROLS ASSOCIATED WITH FUEL OIL PUMP. REMOVE AND DISPOSE OF CMCS CONTROLS ASSOCIATED WITH HOT WATER PUMP. REVIEWED FOR CPE COMPLIANCE APPROVED 1JUN132013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA .JUNE 0.6 2013 PERMIT CENTER CASNE ENGINEERING, INC. EELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14-02 COL. A -F/1-4 THOMPSON, WA (425) 522-1000 WWW.CASNE.COM JOB NO. 1231-085 CURRENT REVISION 15796 SYMBOL A _� IE2IOR JOB NO. DATE DWG NO. 14-002-1E21OR AM STATION MIli W8x20 TYP. IFT DIV 1 AREA INSIDE) CONCRETE CURB >/ libli 70.01.1 W/STEEL PLATE 70.01.2 Pr 4 - #14 THHN /j 70.04.1 — 70.06.1 w H K) 2-#18 TSP /AC1\ 9E1- i MAKE-UP �— .B2, M A PUMP#1 A 5HP 1 E210L501 '1 ' of k ► 0 A /AD 1\ or , ;1 �il A B2 70.03.1 70.03.2 4 - #14 THHN 70.22.1 rii/lajd), HGENERATOR#2 H.W. GENERATOR#1 70.04.2 70.06.2 TSP .W. i®_18 2#TSP o 70.08.1 AilA . I ,0T 'HoI — D---7 AC2 �B3\ REFER MCC5 TSP AIR DRYER pr 4 207, �AD2\ ►.'I' , I 3 B3 - //, SCHRAMM AIR COMPR 50HP - 480V __ __350KW e RA LING EMERGENCY GENERATOR 480/277V 30(::::) 4W - 60HZ SUMP-) TER —'' Q - - - - - 1 1 T . �T BY APPROVED DATE SYM REVISION BY APPROVED DATE A 14-02 BOILER REPLACEMENT 15796 CASNE 12.21.12 AUSFAC, A if ® PNL X4P1 GENERATOR CONTROL PANEL LOAD BANK 400AF FEEDER CB 350AT M3�77 REMOVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN A. TURNBULL CHECKED roiNEER CHECKED DATE 11.05.02 SUBTITLE ISSUE FOR CONSTRUCTION CMCS PLAN LECE\D FLOW SENSOR TEMPERATURE SENSOR HUMIDITY SENSOR PRESSURE SENSOR DIFFERENTIAL PRESSURE SWITCH EED SOLENOID VALVE PV ELECT CONTROLLED PNEU VALVE ELO SMOKE DETECTOR ® MOTORIZED ACTUATOR INLET VANE GUIDE MODULAR BUILDING CONTROLLER MBC EXPANSION PANEL ® CMCS CONTROLLED MOTOR STARTER TRUNK JUNCTION BOX MOTOR OPERATED VALVE AO LEVEL SENSOR/SWITCH TSP #18 TWISTED SHIELDED PAIR CABLE IG MBC EXP FIELD GE\ 107/01 POINT TERM LOCATION IN PNL 107 PRI PNL# (SCU RPU) 107101 SEC PNL# (DPU MPU) WITH ITS PRIMARY PANEL NO. ERAL \OTES 1 • ALL CONDUIT TO BE 1/2" E.M.T. UNLESS 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE 3. THE FOLLOWING COLOR CODING OF CONDUCTORS CO\ STUCTIO\ \OTES REMOVE AND DISPOSE OF EXISTING CONTROL PANEL, CONDUIT AND CONDUCTORS BACK TO SOURCE. REMOVE AND DISPOSE OF ANY CMCS CONTROLS ASSOCIATED WITH FUEL OIL PUMP. REMOVE AND DISPOSE OF CMCS CONTROLS ASSOCIATED WITH HOT WATER PUMP. REVIEWED FOR CPE COMPLIANCE APPROVED 1JUN132013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA .JUNE 0.6 2013 PERMIT CENTER CASNE ENGINEERING, INC. EELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14-02 COL. A -F/1-4 THOMPSON, WA (425) 522-1000 WWW.CASNE.COM JOB NO. 1231-085 CURRENT REVISION 15796 SYMBOL A _� IE2IOR JOB NO. DATE DWG NO. 14-002-1E21OR r Replacement\_Drawings\E502R.dwg 0 CO N 0 0 0 CD 1 1) co 0 t) N N_ M 0 0 0 ai rn N 0 N SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED Caution: Opening Disconnect Switch will also De -energize "LO" Nitrogen Relav Killing both Boilers A B C D E Spare W/ Hardware 1 ' - - o - ' • ' - - AMP TRIP POLE FRAME SIZE © A 175A CB 60HPp Air Comp #1 2 CONTROL 2 NCux A-1 1 1 100A Ckt Bkr 60HP Air Comp #2 2 Size -1- 5HP Hot Water Make -Up 800A CKT BKR 175A CKT BKR 2 1 f 100A -CB. SPARE 3L - 3R -41 Main A 3 15 4 . • 175 500A CKT BKR Boiler House PNL 31BH 4 150A CB Pump Hs PNL 31PH 5 225A CKT BKR SPR-TFJ 4 Incoming Feeder 4 Spare W/ Hardware 6 A-3 — MCC - 5 - Bldg 14-02 - Fed from Sub T4/A2 -ITE SO#3197-(Old MCC#5) 1200 AMP MAIN BUS - FEED Bottom Right - 50,000 AMP BRACING Breaker Data See Sheet E130 CIRCUIT No MCC - 5 -NAMEPLATE MOTOR CIRCU T BRKR MOTOR STARTER HP VOLTS PHASE AMP TRIP POLE FRAME SIZE COIL IND LT ANO CONTROL NCux A-1 — A-2 Air Compressor #1 60 460 3 175 3 FJ -3 A-3 — A-4 — A-5 PNL 31PH (PUMP HOUSE) 150 3 HF -3 A-6 /, 41 //A011/4I, I Pit441VW////////44/V/A/AC AV,,E6/3//3//71,0//////1////1// :—. •• - 42"A//43 �/i, iIlJ i6/////////WA ° 74/4 // /4///1'07//// ///1// — pare le — C-4 PNL 31BH 500 3 KM -3 // j'-1//. elr //1/ K4 ' 6. /1/,/f/F2-7 3 /// / • ) 7: / /7(7,2 : 2071/ D-4 Wire Way DATE A 14-02 BOILER REPLACEMENT 15796 CASNE 12.21.12 rzrEyrAw ® �r- REM OVAL ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN DATE CHECKED SUBTITLE x'113-077 CO \S -RUCTION OTES REMOVE AND DISPOSE OF EXISTING CIRCUIT BREAKER, CONDUIT AND CONDUCTORS FROM MCC5 TO BOILER. REMOVE AND DISPOSE OF EXISTING CIRCUIT BREAKER, STARTER, CONDUIT AND CONDUCTORS FROM MCC5 TO FUEL OIL PUMP. REMOVE AND DISPOSE OF EXISTING CONDUIT AND CONDUCTORS FROM MCC5 TO HOT WATER PUMP. LEAVE CIRCUIT BREAKER AND STARTER IN PLACE AS A SPARE AND LABEL THE BUCKET TO REFLECT THIS. REMOVE AND DISPOSE OF EXISTING CONDUIT AND CONDUCTORS FROM MCC5 TO FUEL OIL PUMP. LEAVE CIRCUIT BREAKER AND STARTER IN PLACE AS A SPARE AND LABEL THE BUCKET TO REFLECT THIS. ISSUE FOR CONSTRUCTION REVIEWED FOR CODE COMPLIANCE APPROVED IJUN 132013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0,6 2013 PERMIT CENTER MCC #5 ELEV & EQUIP LIST DETAIL - BOILER HOUSE CASNE ENGINEERING, INC. EELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE C0M JOB NO. 1231-085 CURRENT REVISION 15796 SYMBOL A DATE 12.21.12 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14-002 COL. X—X/X—X THOMPSON, WA SHEET E502R JOB NO. COMP N DWG NO. 14-002—E502R TAE9937: 06/27/11 14:07 14-02 Boiler Replacement\_Drawings\1 E60.dwq 231-085 FSi Boe €v 0 0 0) d' O (A) ASPHALT RAUP� TS 3x3x3/16 TYP GAS METERS SEWER LIFE STATION (CLASS 1 DIV 1 AREA INSIDE) / M9 5HP � LSH305 LSL305 LSLL305 LSHH304 SYM W8x20 TYP. CONCRETE CURB W/STEEL PLATE LIFT STATION L PANEL CMCS CONTROL PANEL TOP OF PANEL IS 6' AFE r1 1E60 E500 1/2"C,2#14 TO ALARM PANEL "RCC" IN BLDG 14-03 SEE RASTER FILE 114-003-2001-E142 TRENCH REVISION REFER AIR DRYER SUMP ) LADDER � BY APPROVED DATE SYM R TA LS OT SI- h RASTER � REVISION BY APPROVED DATE A SEWER LIFT STATION J#D83F0884 LRW 7.8.98 CAD CONVERSION CADDNW 09.08.98 0 N N r B INSTALL AIR COMPRESSOR 522267-01 MBS CAS 6/14/02 C INSTALL CMCS 522267-01 MBS CAS 12/6/02 D 14-02 BOILER REPLACEMENT 15796 CASNE 12.21.12 R 11 -AS 0 T 114002 Q� BOE/NG' o'— S FSO DC. ACC EPTABI LITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED OVED BY DEPT. DATE DRAWN L.WILLIAMS DATE 7.8.98 CHECKED VUio77 LEGE\ D GE ERAL OTES 1. ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600V OR LESS, 120/208 277/480V "A"PHASE LEFT BUS IN PANEL) BLACK BROWN "B"PHASE CENTER BUS IN PANEL)RED ORANGE "C"PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. USE #10 THWN/THHN FOR COMMON NEUTRAL CONDUCTOR IN ALL 20 AMP MULTI -BRANCH RUNS. 8. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. 9. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. CO\STUCTIO\ \OTES USE EXISTING 20A/1 -PHASE CIRCUIT BREAKER IN PANEL TO POWER TEMPERATURE SENSORS IN BOILER STACK. CONTRACTOR TO RED -LINE SHEETS TO SHOW CIRCUIT THAT WAS USED. PROVIDE CONDUIT AND CONDUCTORS FROM UNIT HEATERS TO PANEL A3-1. TERMINATE AT EXISTING 20A CIRCUIT BREAKER IN CIRCUIT 8. SUBTITLE ISSUE FOR CONSTRUCTION 120/208 VOLT POWER PLAN w REVIEWED FOR CODE COMPLIANCE APPROVED IJUN132013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0,62013 PERMIT CENTER CASNE ENGINEERING, INC. EELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 1231- SYM 231, CURRENT REVISION SYMBOL D DATE 12.21.1 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14.02 COL. A -F/1-4 THOMPSON, WA SHEET 1 E60 JOB NO. COMP NO. DWG NO. .14-002-1 E60 DUARTEE: 1/4/2011 14-02 Boiler Replacement\_Drawings\1 e1 1 0.dwg —085 FSi Boe r7 N N rt) 0 0 0 c 0 N rr) r6) 0 N CN 1 LSH305 LSL305 LSLL305 LSHH304 M9 5HP 3/4HP SUMP PUMP 1/2"C,3# 12,2#14 RIGID U—GRD SEWE�� (CLASS 1 M10 5HP IFT STATION DIV 1 AREA INSIDE) 30 DIS ONNECT "C,6#12PWR & 8#14CNTRL SEWER LIFT STATION CONTROL PANEL 3/4"C,3#8 PNL.A3/20,22,24 MAKE—UP 1"C,3#12 & 3#14 Q O PUMP#1 MCC5/C2 L HEAT MR VA I—R AIR COMPRESSOR 60 HP 480V MCC5/B-3L 3/4"C-3#12, #12GND 1E110 E500 100A PNL A3/32,34,36 Feed to Propane Tank Bldg. 14-05 SYM MCC5/D-3L 3/4;C-3#12, #12GND H.W. PUMP P-1 3/4"C-3#12, #12GND 6 B-1 CONTROL AD -1 4"C,3#12,1 #10GND PNL.A3— PANEL (11 a,b,c) cMcs U ATS Q �� Compressor Cooling Tower Alarm Panel MCC5/B-3R 1 3/4"C-3#12, #12GND VFD P-1 VFD P-2 VFD P-3 MCC5/D-2R 3/4"C-3#12, #12GND 3/4"C-3#12, #12GND H.W. PUMP P-2 B-2 REFER AIR DRYER 1-1 /2"C,3#2,1 #6GND TO MCC 5 A3/ 9abc MCC5/C-3R 2 3/4"C-3#12, #12GND 3/4"C-3#12, #12GND H.W. PUMP P-3 350KW EMERGENCY GENERATOR 480/277V 30 4W — 60HZ PULL BOX Incoming Conduit Pull Box GENERATOR CONTROL PANEL 2 1 /2"AL(3)350MCM PNL X4P1 2 1 /2"AL(3)350MCM LOAD BANK 300KW-30,480V REVISION 4/0 CU GROUNG WIRE (TYPICAL) BY APPROVED DATE SYM REVISION BY APPROVED DATE A SEWER LIFT STATION J#D83F0884 LRW 7.8.98 B CAD CONVERSION CADDNW 09.08.98 C INSTALL AIR COMPRESSORS 522267-01 MBS CAS 6/14/04 D INSTALL VFD INPUT REACTOR 1001718824 MBS E 14-02 BOILER REPLACEMENT 15796 CASNE 12.21.12 QtBOE/NG° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN L.WILLIAMS CHECKED LOAD BANK 400AF FEEDER CB 350AT h113-0 77 DATE 7.8.98 SUBTITLE GENERATOR RADIATOR REVIEWED FOR CODE COMPLIANCE APPROVED 1 JUN 13 2013 City of Tukwila BUILDING DIVISION LEGE\D S❑ Stop Button with Lockout GES HAL \OTES 1. ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600V OR LESS, 120/208 277/480V "A"PHASE LEFT BUS IN PANEL) BLACK BROWN "B"PHASE CENTER BUS IN PANEL)RED ORANGE "C"PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. ISSUE FOR CONSTRUCTION 277/480 VOLT POWER PLAN FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. USE #10 THWN/THHN FOR COMMON NEUTRAL CONDUCTOR IN ALL 20 AMP MULTI—BRANCH RUNS. 8. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. CONST UCTIO\ OYES PROVIDE 30A RATED NON—FUSED DISCONNECT. PROVIDE CONDUIT AND CONDUCTORS FROM DISCONNECT TO BOILER. CONTRACTOR TO VERIFY EXACT LOCATION OF SINGLE POINT CONNECTION TO BOILER. PROVIDE CONDUIT AND CONDUCTORS FROM NON—FUSED DISCONNECT TO MCC5. MAKE TERMINATION AT BREAKER IN MCC5. SEE SHEET E502 FOR REVISIONS TO MCC. PROVIDE CONDUIT AND CONDUCTORS FROM VFD TO MCC5. MAKE TERMINATION AT BREAKER IN MCC5. PROVIDE CONDUIT AND CONDUCTORS AS SHOWN FROM VFD TO ASSOCIATED HOT WATER PUMP. GROUND EQUIPMENT TO EXISTING BUILDING GROUND RING. PROVIDE SELF ENCLOSED VFD, ALLEN—BRADLEY/ROCKWELL POWERFLEX 400 WITH CATALOG NUMBER 23C — D 017 A 1 0 B N NAANN —LR. PROVIDE STRUT RACK MOUNTED TO FLOOR JUST IN FRONT OF WALL BRACING TO MOUNT VFDS. CONTRACTOR TO ENSURE A MINIMUM OF 42" OF WORKING CLEARANCE. RECEIVED CITY OF TUKWILA JUN 0:6 2013 PERMIT CENTER CASNE ENGINEERING, INC. EELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 1231-085 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14-02 COL. A—F/1-4 THOMPSON, WA CURRENT REVISION 15796 SHEET JOB NO. SYMBOL 1E110 DWG NO. .14-002-1E110 00 M N VAVREKJ: 05/21/12 CONTROL AD -1 4"C,3#12,1 #10GND PNL.A3— PANEL (11 a,b,c) cMcs U ATS Q �� Compressor Cooling Tower Alarm Panel MCC5/B-3R 1 3/4"C-3#12, #12GND VFD P-1 VFD P-2 VFD P-3 MCC5/D-2R 3/4"C-3#12, #12GND 3/4"C-3#12, #12GND H.W. PUMP P-2 B-2 REFER AIR DRYER 1-1 /2"C,3#2,1 #6GND TO MCC 5 A3/ 9abc MCC5/C-3R 2 3/4"C-3#12, #12GND 3/4"C-3#12, #12GND H.W. PUMP P-3 350KW EMERGENCY GENERATOR 480/277V 30 4W — 60HZ PULL BOX Incoming Conduit Pull Box GENERATOR CONTROL PANEL 2 1 /2"AL(3)350MCM PNL X4P1 2 1 /2"AL(3)350MCM LOAD BANK 300KW-30,480V REVISION 4/0 CU GROUNG WIRE (TYPICAL) BY APPROVED DATE SYM REVISION BY APPROVED DATE A SEWER LIFT STATION J#D83F0884 LRW 7.8.98 B CAD CONVERSION CADDNW 09.08.98 C INSTALL AIR COMPRESSORS 522267-01 MBS CAS 6/14/04 D INSTALL VFD INPUT REACTOR 1001718824 MBS E 14-02 BOILER REPLACEMENT 15796 CASNE 12.21.12 QtBOE/NG° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN L.WILLIAMS CHECKED LOAD BANK 400AF FEEDER CB 350AT h113-0 77 DATE 7.8.98 SUBTITLE GENERATOR RADIATOR REVIEWED FOR CODE COMPLIANCE APPROVED 1 JUN 13 2013 City of Tukwila BUILDING DIVISION LEGE\D S❑ Stop Button with Lockout GES HAL \OTES 1. ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600V OR LESS, 120/208 277/480V "A"PHASE LEFT BUS IN PANEL) BLACK BROWN "B"PHASE CENTER BUS IN PANEL)RED ORANGE "C"PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. ISSUE FOR CONSTRUCTION 277/480 VOLT POWER PLAN FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. USE #10 THWN/THHN FOR COMMON NEUTRAL CONDUCTOR IN ALL 20 AMP MULTI—BRANCH RUNS. 8. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. CONST UCTIO\ OYES PROVIDE 30A RATED NON—FUSED DISCONNECT. PROVIDE CONDUIT AND CONDUCTORS FROM DISCONNECT TO BOILER. CONTRACTOR TO VERIFY EXACT LOCATION OF SINGLE POINT CONNECTION TO BOILER. PROVIDE CONDUIT AND CONDUCTORS FROM NON—FUSED DISCONNECT TO MCC5. MAKE TERMINATION AT BREAKER IN MCC5. SEE SHEET E502 FOR REVISIONS TO MCC. PROVIDE CONDUIT AND CONDUCTORS FROM VFD TO MCC5. MAKE TERMINATION AT BREAKER IN MCC5. PROVIDE CONDUIT AND CONDUCTORS AS SHOWN FROM VFD TO ASSOCIATED HOT WATER PUMP. GROUND EQUIPMENT TO EXISTING BUILDING GROUND RING. PROVIDE SELF ENCLOSED VFD, ALLEN—BRADLEY/ROCKWELL POWERFLEX 400 WITH CATALOG NUMBER 23C — D 017 A 1 0 B N NAANN —LR. PROVIDE STRUT RACK MOUNTED TO FLOOR JUST IN FRONT OF WALL BRACING TO MOUNT VFDS. CONTRACTOR TO ENSURE A MINIMUM OF 42" OF WORKING CLEARANCE. RECEIVED CITY OF TUKWILA JUN 0:6 2013 PERMIT CENTER CASNE ENGINEERING, INC. EELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 1231-085 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14-02 COL. A—F/1-4 THOMPSON, WA CURRENT REVISION 15796 SHEET JOB NO. SYMBOL 1E110 DWG NO. .14-002-1E110 00 M N VAVREKJ: 05/21/12 REFER AIR DRYER 1-1 /2"C,3#2,1 #6GND TO MCC 5 A3/ 9abc MCC5/C-3R 2 3/4"C-3#12, #12GND 3/4"C-3#12, #12GND H.W. PUMP P-3 350KW EMERGENCY GENERATOR 480/277V 30 4W — 60HZ PULL BOX Incoming Conduit Pull Box GENERATOR CONTROL PANEL 2 1 /2"AL(3)350MCM PNL X4P1 2 1 /2"AL(3)350MCM LOAD BANK 300KW-30,480V REVISION 4/0 CU GROUNG WIRE (TYPICAL) BY APPROVED DATE SYM REVISION BY APPROVED DATE A SEWER LIFT STATION J#D83F0884 LRW 7.8.98 B CAD CONVERSION CADDNW 09.08.98 C INSTALL AIR COMPRESSORS 522267-01 MBS CAS 6/14/04 D INSTALL VFD INPUT REACTOR 1001718824 MBS E 14-02 BOILER REPLACEMENT 15796 CASNE 12.21.12 QtBOE/NG° ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN L.WILLIAMS CHECKED LOAD BANK 400AF FEEDER CB 350AT h113-0 77 DATE 7.8.98 SUBTITLE GENERATOR RADIATOR REVIEWED FOR CODE COMPLIANCE APPROVED 1 JUN 13 2013 City of Tukwila BUILDING DIVISION LEGE\D S❑ Stop Button with Lockout GES HAL \OTES 1. ALL CONDUIT TO BE 1/2" E.M.T. UNLESS OTHERWISE NOTED. 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE NOTED. 3. THE FOLLOWING COLOR CODING OF CONDUCTORS SHALL BE OBSERVED ON ALL CIRCUITS 600V OR LESS, 120/208 277/480V "A"PHASE LEFT BUS IN PANEL) BLACK BROWN "B"PHASE CENTER BUS IN PANEL)RED ORANGE "C"PHASE RIGHT BUS IN PANEL) BLUE YELLOW NEUTRAL WHITE GRAY EQUIPMENT GROUND GREEN 4. LARGE SIZE CONDUCTORS WHICH DO NOT HAVE COLORED JACKETS SHALL BE IDENTIFIED WHEREVER VISIBLE BY APPROPRIATELY COLORED TAPE. 5. ALL UNUSED CONDUIT AND WIRE TO BE REMOVED BACK TO SOURCE. ISSUE FOR CONSTRUCTION 277/480 VOLT POWER PLAN FEEDERS TO PANELS AND BUSWAYS SHOWN ON SHEETS E2 AND E3. USE #10 THWN/THHN FOR COMMON NEUTRAL CONDUCTOR IN ALL 20 AMP MULTI—BRANCH RUNS. 8. DYMO LABEL ALL RECEPTACLES, JUNCTION BOXES, SWITCHES, ETC., WITH CIRCUIT IDENTIFICATION. INSTALL REVISED PANEL SCHEDULES UPON COMPLETION OF JOB. CONST UCTIO\ OYES PROVIDE 30A RATED NON—FUSED DISCONNECT. PROVIDE CONDUIT AND CONDUCTORS FROM DISCONNECT TO BOILER. CONTRACTOR TO VERIFY EXACT LOCATION OF SINGLE POINT CONNECTION TO BOILER. PROVIDE CONDUIT AND CONDUCTORS FROM NON—FUSED DISCONNECT TO MCC5. MAKE TERMINATION AT BREAKER IN MCC5. SEE SHEET E502 FOR REVISIONS TO MCC. PROVIDE CONDUIT AND CONDUCTORS FROM VFD TO MCC5. MAKE TERMINATION AT BREAKER IN MCC5. PROVIDE CONDUIT AND CONDUCTORS AS SHOWN FROM VFD TO ASSOCIATED HOT WATER PUMP. GROUND EQUIPMENT TO EXISTING BUILDING GROUND RING. PROVIDE SELF ENCLOSED VFD, ALLEN—BRADLEY/ROCKWELL POWERFLEX 400 WITH CATALOG NUMBER 23C — D 017 A 1 0 B N NAANN —LR. PROVIDE STRUT RACK MOUNTED TO FLOOR JUST IN FRONT OF WALL BRACING TO MOUNT VFDS. CONTRACTOR TO ENSURE A MINIMUM OF 42" OF WORKING CLEARANCE. RECEIVED CITY OF TUKWILA JUN 0:6 2013 PERMIT CENTER CASNE ENGINEERING, INC. EELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 1231-085 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14-02 COL. A—F/1-4 THOMPSON, WA CURRENT REVISION 15796 SHEET JOB NO. SYMBOL 1E110 DWG NO. .14-002-1E110 00 M N VAVREKJ: 05/21/12 14-02 Boiler Replacement\_Drawings\1 e210.dwg I:\D3\12\1231-085 FSi Iane.wood (F) SEWER / (CLASS IFT STATION DIV 1 AREA INSIDE) MAKE-UP PUMP#1 5HP ASPHALT RAM P TS 3x3x3/16 TYP GAS METERS 70.01.1 70.01.2 4 - #14 THHN 70.04.1 70.06.1 -HD 2 - # 18 TSP SUMP _ADDER —' LOAD BANK 300KW-30,480V 03 70.03.2 4 - #14 THHN 70.04.2 70.06.2 2- #18 TSP SCHRAMM JR COMPI 50HP 480V 0 TS REFER AIR DRYER 70.22.1 70.08.1 /7Sp /AD2\ B3 350KW EMERGENCY GENERATOR 480/277V 30 4W - 60HZ 12/20/12 15:04:10 REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE 14-02 BOILER REPLACEMENT 15796 CASNE 12.21.12 PP,Mw,AW PNL X4P1-/I ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED A PROVED BY DEPT. DATE GENERATOR CONTROL PANEL LOAD BANK 400AF FEEDER CB 350AT Mt 4-•071 DRAWN A. TURNBULL DATE 11.05.02 CHECKED ENGINEER CHECKED APPROVED APPROVED SUBTITLE TITLE REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 132013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0:62013 PERMIT CENTER LEGE\ J ED CD SV PV SD IG MBC EXP JB TSP FLOW SENSOR TEMPERATURE SENSOR HUMIDITY SENSOR PRESSURE SENSOR DIFFERENTIAL PRESSURE SWITCH SOLENOID VALVE ELECT CONTROLLED PNEU VALVE SMOKE DETECTOR MOTORIZED ACTUATOR INLET VANE GUIDE MODULAR BUILDING CONTROLLER MBC EXPANSION PANEL CMCS CONTROLLED MOTOR STARTER TRUNK JUNCTION BOX MOTOR OPERATED VALVE LEVEL SENSOR/SWITCH #18 TWISTED SHIELDED PAIR CABLE FIELD 107/01 `POINT TERM LOCATION IN PNL 107 PRI PNL# (SCU RPU) 107101 SEC PNL# (DPU MPU) WITH ITS PRIMARY PANEL NO. GE\EAL OTES ALL CONDUIT TO BE 1/2" E.M.T. UNLESS 2. ALL WIRE TO BE #12 THWN UNLESS OTHERWISE 3. THE FOLLOWING COLOR CODING OF CONDUCTORS CO\STUCTIO\ \OTES PROVIDE 1" CONDUIT, WITH PULL STRING, FROM BOILER CONTROL PANEL TO J -BOX AND THEN TO EXISTING CMCS PANEL. WIRING AND PROGRAMING BY OTHERS. PROVIDE 1" CONDUIT, WITH PULL STRING, FROM VFDS TO EXISTING CMCS PANEL. WIRING AND PROGRAMING BY OTHERS. PROVIDE 3/4" CONDUIT AND WIRING FROM E -STOP TO TERMINAL BLOCKS FOR AUTOMATIC SHUT DOWN OF BOILERS. CONTRACTOR TO VERIFY EXACT LOCATION OF TERMINAL BLOCKS ON BOILER. PROVIDE MUSHROOM HEAD TYPE E -STOP WITH OVERSIZED HEAD, PUSH BUTTON GUARD AND BOTH N.O. AND N.C. CONTACTS. MOUNT E -STOP NEXT TO DOOR. E -STOP SHALL BE CAPABLE OF SHUTTING OFF POWER TO BOILERS B-1, B-2, B-3 VIA DAISY CHAIN CONNECTION. ELECTRICAL MASTER ISSUE FOR CONSTRUCTION CMOS PLAN BUILDING 14-02 COL. A -F/1-4 CASNE ENGINEERING, INC. EELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL, SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW. CASNE. COM JOB NO. 1231-085 THOMPSON, WA CURRENT REVISION 15796 SHEET SYMBOL A E 12.©1.12 1E210 JOB N0. DWG NO. 14-002-1E210 rn N w r Replacement\_Drawings\E502.dwq N 0 0 0 0 0 N N N) 0 N N SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED Caution: Opening Disconnect Switch will also De -energize "LO" Nitrogen Relav Killing both Boilers A B C CIRCU D E Spare W/ Hardware Size 3-50HP SPARE 3 VOLTS Size 3-50HP SPARE 3 AMP TRIP Size -1-1 HP SPARE FRAME SIZE 2 1 1 175A CB 60HP Air Comp #1 2 ON CTROL 1 30A -CB H.W. PUMP P-2 2L 30A -CB H.W. PUMP P-3 �© 2R 1 100A Ckt Bkr p#2 2 Ize Hot Water P Make -Up 175AC BKR 3 •'HP irCo '� 2 800AC C2 Mai IA 3 60 20A -CB BOILER 20A -CB BOILER #2 3R 3 .W.13 PUMP P-1 3L 20A -CB BOILER #3 3R 150A C BKR 4 #1 3L AAA KT : ' ' 4 500' KT : " Boiler House PNL 31 BH 4 150A CB Pump Hs PNL 31 PH 5 22 ' SPR-TFJ Incoming Feeder 4 Spare W/ Hardware 6 A MCC - 5 - Bldg 14-02 - Fed from Sub T4/A2 -ITE SO#3197-(Old MCC#5) 1200 AMP MAIN BUS - FEED Bottom Right - 50,000 AMP BRACING Breaker Data See Sheet E130 CIRCUIT No MCC - 5 -NAMEPLATE MOTOR CIRCU T BRKR MOTOR STARTER HP VOLTS PHASE AMP TRIP POLE FRAME SIZE COIL IND LT Aux ON CTROL NO NC A-1 — A-2 Air Compressor #1 60 460 3 175 3 FJ -3 A-3 — A-4 — A-5 PNL 31 PH (PUMP HOUSE) 150 3 HF -3 A-6 B-1 SPARE 100 3 EF -3 3 120 1 1 B -3L BOILER #1 2 460 3 20 3 B -3R BOILER #2 2 460 3 20 3 :-- • i e TFJ C-1 SPARE 225 3 EF -3 3 120 1 1 s..e-;1'4,,.�.0-40,.,r.0)-vr•- +40..,..01. �t * * J ., — 1 1 1 C -3L HOT WATER PUMP #1 10 460 3 30 3 C -3R BOILER #3 2 460 3 20 3 , - 1. 0. KM -3 D-1 SPARE 20 3 EF -3 1 120 1 1 • D -2L HOT WATER PUMP #2 10 460 3 30 3 • D -2R HOT WATER PUMP #3 10 460 3 30 3 1- Yain ircui :rea er ;I. ' v D-4 Wire Way DATE A 14-02 BOILER REPLACEMENT 15796 CASNE 12.21.12 Q� BOE/NG' o'— ACCEPTABILITY THIS DESIGN AND/OR SPECIFICATION IS APPROVED DEPT. DATE DRAWN DATE CHECKED CO\ STUCTIO\ \OTES PROVIDE MCC BUCKET WITH DUAL CIRCUIT BREAKERS FROM MCC MANUFACTURER. CONSTRUCTION SHALL BE SIMILAR TO WHAT WAS DONE IN BUCKET C -3L AND C -3R. PROVIDE 20A, 3—PHASE CIRCUIT BREAKER IN MCC SPACE AND LABEL SPACE AS SHOWN. RELABEL BUCKET TO REFLECT SPARE BREAKER AND STARTER. PROVIDE 30A, 3—PHASE CIRCUIT BREAKER IN MCC SPACE AND LABEL SPACE AS SHOWN. Mk 3%. 0 77 ISSUE FOR CONSTRUCTION REVIEWED FOR CODE COMPLIANCE APPROVED 'JUN 13 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0.6 2013 PERMIT CENT1"13 SUBTITLE MCC #5 ELEV & EQUIP LIST DETAIL - BOILER HOUSE CASNE ENGINEERING, INC. EELECTRICAL AND TECHNOLOGY CONSULTANTS 10604 NE 38th PL., SUITE 205 KIRKLAND, WA 98033 (425) 522-1000 WWW.CASNE.COM JOB NO. 1231-0 CURRENT REVISION 15796 SYMBOL A DATE 12 21.12 ENGINEER CHECKED APPROVED APPROVED TITLE ELECTRICAL MASTER BUILDING 14-002 COL. X-X/X-X THOMPSON, WA SHEET E502 JOB NO. COMP NO. DWG NO. 14-002—E502 06/27/11 14:07 N M w