HomeMy WebLinkAboutPermit M13-088 - TOYS R US - REPLACE ROOF TOP UNITSTOYS R US 17501 SOUTHCENTERPY M13-088 City otkI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 2623049067 17501 SOUTHCENTER PY TUKW Project Name: TOYS R IIS Permit Number: M13-088 Issue Date: 06/14/2013 Permit Expires On: 12/11/2013 Owner: Name: Address: Contact Person: Name: Address: Email: CLPF-TIIKWILA LP C/O JSH PROPERTIES INC , 10655 NE 4TH ST #901 98004 MICHAEL ATWOOD 9630 153RD AVE NE , REDMOND WA 98052 MATW OOD @MERITMEC HANICAL. C OM Contractor: Name: MERIT MECHANICAL INC. Address: 9630 153 AV NE , REDMOND, WA 98052 Contractor License No: MERITMI163CM Phone: (425)883-9224 Phone: 425 883-9224 Expiration Date: 06/01/2015 DESCRIPTION OF WORK: REPLACE (5) EXISTING ROOFTOP GAS/ELECTRIC UNITS Value of Mechanical: $18,752.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie x. with, The granting of this permit does not pres construction or the performance of work. back of this permit. Signature: Print Name: Fees Collected: $416.31 International Mechanical Code Edition: 2009 Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: 06////3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 11A4o naa Drint ,1 f1R_17_9M4 PERMIT CONDITIONS Permit No. M13-088 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***FIRE DEPARTMENT CONDITIONS*** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 11: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 12: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 13: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 16: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IMC -4/10 M13-088 Printed: 06-17-2013 City ofiI'ukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.ov MECHANICAL PERMIT Parcel No.: Address: 2623049110 17500 SOUTHCENTER PY TUKW Project Name: TOYS R US Permit Number: M13-088 Issue Date: 06/14/2013 Permit Expires On: 12/11/2013 Owner: Name: Address: Contact Person: Name: Address: Email: KIR TUKWILA 050 LLC C/O KIMCO REALTY CORP , 3333 NEW HYDE PARK RD #100 PO BOX 5020 11042 MICHAEL ATWOOD 9630 153RD AVE NE , REDMOND WA 98052 MATWOOD@MERITMECHANICAL.COM Contractor: Name: MERIT MECHANICAL INC. Address: 9630 153 AV NE , REDMOND, WA 98052 Contractor License No: MERITMI163CM Phone: (425)883-9224 Phone: 425 883-9224 Expiration Date: 06/01/2015 DESCRIPTION OF WORK: REPLACE (5) EXISTING ROOFTOP GAS/ELECTRIC UNITS Value of Mechanical: $18,752.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $416.31 International Mechanical Code Edition: 2009 /(4 /// Pte"" ` Date: 0///4? I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: \ Date: I1I1.%13 A-T000b Print Name: This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. .J....• IAA/` A11r1 MI' J RR printed. ng -14-7n11 • PERMIT CONDITIONS Permit No. M13-088 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***FIRE DEPARTMENT CONDITIONS*** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 11: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 12: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 13: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 14: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 16: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this project. 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 18: Arty overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. a root' A/1r1 M1 1-M1R Printed: 06-14-2013 CITY OF TUI A Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No.in 13 ctk Project No. jj Date Application Accepted: O tO k (/ 3' Date Application Expires: / / 0 //3 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** King Co Assessor's Tax No.: 2623049067 Site Address: 17500 Southcenter Parkway Suite Number: Floor: Tenant Name: Toys -R -Us PROPERTY OWNER Name: Michael Atwood Name: CLPF-TUKWILA LP City: Redmond State: WA Zip: 98052 Address: Email: matwood@meritmehcanical.com City: State: Zip: CONTACT PERSON - person receiving all project communication Name: Michael Atwood Address: 9630 153rd Ave NE City: Redmond State: WA Zip: 98052 Phone: (425) 883-9224 Fax: (425) 867-0962 Email: matwood@meritmehcanical.com New Tenant: ❑ Yes ®..No MECHANICAL CONTRACTOR INFORMATION Company Name: Merit Mechanical, Inc Address: 9630 153rd Ave NE City: Redmond State: WA Zip: 98052 Phone: (425) 883-9224 Fax: (425) 867-0962 Contr Reg No.: MERITMI1 63CM Exp Date: 06/01/2013 Tukwila Business License No.: BUS -0992852 Valuation of project (contractor's bid price): $ 18,752 Describe the scope of work in detail: Replace 5 existing rooftop gas/electric unit with owner provided new units. Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric Gas Other: H:Wppltcauons\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-I1.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu 1 Furnace>100k btu 4 Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDI OWNER il' AUTH IZED AG ' . T: Signature: Print Name: Michael Atwood Mailing Address: 9630 153rd Ave NE H:Wpplications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: 05/08/2013 Day Telephone: (425) 883-9224 Redmond WA 98052 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT ParcelNo.: 2623049110 Permit Number: M13-088 Address: 17500 SOUTHCENTER PY TUKW Status: PENDING Suite No: Applied Date: 05/08/2013 Applicant: TOYS R US Issue Date: Receipt No.: R13-01558 Payment Amount: $416.31 Initials: LAW Payment Date: 05/08/2013 02:56 PM User ID: 1632 Balance: $0.00 Payee: MERIT MECHANICAL INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 24832 416.31 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 333.05 000.345.830 83.26 Total: $416.31 Printati• nc_nR_9n1� INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 M(3—OF Project: ( S 1?-- us Type o Inspection: ,0A.` i el . Address: T o l sc p �� Date Called: 1 $ted Gee S C•J fl a Special Instructions: j 0-7 i.....4 . 3- — i QJPhone 7 Date Wanted: ,---'.mj I0 —1 / �! -/3 aP.m. Requester: ` \1 14M No: n 7 '12.-5445—I49 7 Approved per applicable codes. Corrections required prior to approval. COMMENTS: i / Zid *V- 3 KC -Li M--51 ?PrM7A '\ € Insp ctor:ak)t-P A / i Date] O f' / I 3 REINSPECTION FE_ REQUIRBD. F rior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit M(3_on INSPECTION NO. PERMIT N0. .,t,, CITY OF TUKWILA BUILDING DIVISION / 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:Typ c as (� Us f Inspection: t J A -L._ ,U .c Address: 19 0 I Se_ p A4'kJ4 Date Called: Special Instructions: D--7o1.2-41.--d°( S.40,::-.)- A,M. Date Wanted:q _ ' ! 3 3 p.m. Reue er:., �P ( Phone No: Z,—..4s—/o71 Approved per applicable codes. corrections required prior to approval. COMMENTS: \ 1 v i V , .L ilF I L/1 / - �� AZ/ 7 V4T' �.J . l� fit. N Sr- re (E (e --Th --3 J`: ado � �P ( r -.(' (Ce --,_S c.1),,tolJt e A�4%' t) L1A J \Sv6 � c - � rCf� 4)- Q A (--k Xs( U c (eAC %l' '7 '. rc &AA-; a`Ari u i s . Insbector: n REINSPECTION FEE REQUIiItED. Prior to next inspection, fee must be paid at 6300 Southcenter Bl d.. Suite 100. Call to schedule reinspection. Dater!(3 —L3 II\1$'tCTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 ; y.., (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: Tc.---t-r; t2-t-l< Typ of Inspection: „ in l..'in - 0 N.) Vo). Address: t1"6 1 Sad CeFkif . -t Date Called: 4 c' V S n+o k e ski ci Act ..)Ni Jai' v -f o Special Instructions: '` Date Wanted: CO _ 2-C, - ? a.m_, p.m. Requester: Phone No: tt-i2-5-1-1 y'- 1 '07 5 tJApproved per applicable codes. 1__.J Corrections required prior to approval:- COMMENTS:" \ G) i�C:72Kaill - + IJ AD' O. -j ( 11l rv%4S .,11.s, ,,,e-tt n(- 0 N.) Vo). (4 ) Ctac,e"(:\,t , e %e },+.igQ t r + v (t mit: 1r( ...-0c 4 c' V S n+o k e ski ci Act ..)Ni Jai' v -f o 6...) r ItePif eAI 177, N.---‘ ek1'..-,k- IN -1 C•`cc(E . Inspe t r: Date: Ell SPECTION FEE REVVIREO. Prior to next inspection. fee must be p i at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit 114/3-0' PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Type o Insp ction: Address:/J Suite #: pis® / SC pa►�YW ca Contact Person: Special Instructions: / Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: /e C.Ly / i Needs Shift Inspection: Sprinklers: Fire -Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Z fi3,7cv Date: /e)'/ �/� 3 Hrs.: $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. CaII to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 1 INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit M13 © -- PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Pr�0ct5 l� UIQ / /7-74 - 3 1,0" (icy/ (e2t (7L icy ihe_ / Typ/-/P%Inspection: Addr �s:/ Suite #: te,% ..2r/i Geri' / lt�i,� Contact Person: Special Instructions: , / Phone No.: , Approved per applicable codes. /[5<r Corrections requirediprior to approval. COMMENTS: / /7-74 - 3 1,0" (icy/ (e2t (7L icy ihe_ / 104,442. - e Ty til #7 s W - 5 c___ 1--63 L 644,1 , i 7C L,,,&,‘®/ - �1�'di 0i" LfiWk Pre -Fire: kr l 1,,13- r� U,k . z ,,,,u- /dd 6..m /L C<95'j be CO( �� e'0/A � , S " i'(/v h!'e /T/or{.01 pe,, a'5 ylPeo"� // e S ! -i`z/! �Y � G�i.-/1 ;11 ie - A ` z J P i/%et-u �t-5 f.2cf,st 72pe ci Zeil— r o rr l`' i ,n,- Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspect o 7 7 f Date: e//.�/� Hrs.: / r $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH-SUM 2009 Washington State. Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Info Cort �� p R r . Pe...* Project Address Toys R Us 8002 Tukwila Dat 201E m VE �iCOM PRO 0 17501 Southcenter Parkway For IIdi A JUN ��� Tukwila WA, 98188 Applicant Name: Merit Mechanical Applicant Address: 9830 153RD Ave NE Redmond WA, 98058 Applicant Phone: 1.425.883.9224 Extension 1219 Project Briefly describe system type Description mechanical and features. Plans Replace 5 existing rooftop gas/electric units with owner units. Drawings must contain notes requireing compliance with commissioning requirements roivdednew City of Tul BUILDING DI - Section 1416 J Includes Compliance Option 0 Simple System QQ Complex System O Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH-SUM for simple & complex Equipment Schedules The following information is required to be Incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule Equip. ID Equip Type Brand Name Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmizer Option or Exceptions Heat Recovery YIN RTU -2 LENNOX LGH120H4M 124400 ECONO 12.0 EER N RTU -5 LENNOX LGH120H4M 129900 ECONO 12..0 EER N RTU -6 LENNOX LGH120H4M 124400 ECONO 12.0 EER N RTD -7 LENNOX LGH092R4M 93000 ECONO 12.5 EER N RTU -12 LENNOX LGH120H4M 124400 ECONO 12.0 EER N Heating Equipment Schedule Equip. ID Equip Type Brand Name Model No.1 Capacity2 Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency° Heat Recovery VIN RTU -2 LENNOX LGH120H4M 290000 ECONO 240000 192000 80 N RTU -5 LENNOX LGH12OH4M 29000.0 ECONO 240000 192000 80 N RTU -6 LENNOX LGH120H4M 240000 ECONO 240000 192000 80 N RTD -7 LENNOX LGR092H4M 180000 ECONO 180000 144000 80 N RTU -12 LENNOX LGH120H4M 240000 ECONO 240000 192000. 80 N Fan E. uipment Schedule Equip. ID Equip Type Brand Name Model No.1 CFM SP1 HP/BHP Flow Controls Location of Service 1if available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. 4 COP HSPF, Combustion Efficiency, or AFUE, as applicable. 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number from SE} 3JE D CORRECTION MtO98 D FOR LIANC ED 2013 vita ISION CITY OF TUKWILA MAY 2 4 2013 PERMIT CENTER 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 System Description See Section 1421 for full description of Simple System qualifications. All Systems: No humidification? ✓ No Reheat? If Heating/Cooling or Cooling Only: ® Constantvol7 ❑ Split system? ❑<=84,000 Btuh? ✓ Economizer ISI Air cooled? ❑✓ Packaged sys? ✓ <=135,000 Btuh7 ❑ Heating Cap. >10 & <=10 Btuh/ft2? • Cooling Cap <=15 Btuh/ft2? If Heating Only: E <1000 cfm? • <30% outside air? U Heating Cap. <=10 Btuh/ft2? Decision Flowchart Use this flowchart to determine If project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. Yes ( START C Humidification or Reheat? Yes Heating/Cooling or Cooling Only Heating Only Reference Section 1421 Yes Total CFM Serving Single Roo ,0 Package Unit Cap <=135,000 Btuh Split System <=84,000 Btuh Yes Yes alifles Economizer Exception tion 1 Yes Simple System Allowed (section 1420) 4 Yes Use Complex Systems (section 1430) Complex Systems Refer to MECH-COMPMechanical Complex Systems for assistance In determining which Complex Systems requirements are applicable to this project. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical - Complex Systems Checklist MECH-COMP 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Address 17501 Southcenter Parkway Date 5/21/2013 The following additional information is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements In the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH-CHK checklist for additional requirements). This information must be on the plans since this is the official record of the permit. Having this information in separate specifications alone is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY N.A. 1431.1 Field assem. sys. Provide calculations for total onsite energy Input/output to equip. N.A. 1431.2 System Sizing Indicate equipment & system sizing complies with 1431.2 N.A. 1432.1 Setback & shut-off Indicate separate systems or show isolation devices on plans N.A. 1432.2.1 Air system reset Indicate automatic temperature reset & operation sequence N.A. 1432.2.2 Hydr. Sys. reset Indicate automatic temperature reset & operation sequence N.A. 1432.3.1 Hydr. Var. Flow Indicate variable flow method for all applicable systems N.A. 1432.3.X Hydronic Isolation Indicate method of isolation for all applicable systems N.A. 1432.4 DDC Capabilities Indicate control capabilities including demand response setpoind adj. N.A. 1432.4 DDC data mgmt Indicate metering and trending capabilities. N.A. 1432.5 Pressure Reset Indicate static pressure reset for VAV systems Yes 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption. Demonstrate higher efficiency equipment if required. 142 0 N.A. 1433 Water Economizer Indicate water economizer and provide calculations showing compliance with 1413 if 1433 Exception 3 is utilized N.A. 1434 Separate air sys. Indicate special requirement zones and Indicate systems N.A. 1435 Simul. htg. & dg. Indicate method of prohibiting simultaneous heating and cooling, or state excpetlon and show supporting calculations N.A. 1436 Heat recovery Indicate heat recovery of all applicable systems on plans; complete and attach heat recovery calculations N.A. 1437 Elec. motor effic. MECH-MOT or Equip. Schedule with hp, rpm, efficiency N.A. 1438 Variable speed drives Indicate VS control or equivalent on schedules for ail applicable equip. N.A. 1438.1 Heat Refection Indicate heat rejection equipment types and fan types Yes 1438.2 Hot Gas Bypass Indicate cooling equipment staging and capacity modulation abilities 002.0 N.A. 1438.3 Large Volume sys Indicate multiple system rooms & indicate ventilation control N.A. 1439.1 Kitchen Hoods indicate source and conditioning of make-up air N.A. 1439.2 Laboratory Exhaust Indicate HR, VAV, semi -conditioned makeup, or GERM caic no Is circled for any question, provide explanation: Decision Flowchart Start Here Section 1411.1 Equipment Efficiency Shall Meet Tables 14.1A through 14-10 s/Oil Fuma Input 225,000 uhorAnyU eate Use flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the indicated Code sections for complete information on the requirements. ny Fuel Fuma input 225,000 Btuh? ace >50. with Design > 25 people per 000S field -Assemble Equipment? Air System Serving Multiple Zones? Yes 1411.1 IID&Power Venting or Damper. If Input >_ 225,000 Btuh then 1412.6 Modulating Controls Required Yes Section 1411.1 0.75% Maximum Jacket Loss Yes Section 1412.8 Ventilation Controls for High -Occupancy Areas Yes Section 1431.1 Calculations of Total On -Site Energy Input & Ouput Required Yes section 1432.2.1 Supply Air Reset Controls Required (continued en back) } 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical - Complex Systems (back) MECH-COMP 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 es Section 1432.3.2 through 1432.3.5 Device isolation Required Section 1433 Economizer ReQuired Section 1432.3.1 Yes --9. Variable Flow Design Required dronic Syst Heated or Cooled 300,000 Btu �C Present Total Cooling > 780kBtuh 0 Section 1436.1 50% Effective Heat Recovery Required No 4 Hour Ops, ter Cooled Conden >1,50rkStuh,& Sery Section 1436.3 Condenser Heat Recovery Required emo Refrigeration Condensers 500kBt ystem or Zone w/ Simultaneous tg. & Cig. Yes9. Section 1435 Zone Controls Must Reduce Supply Air Quantity Before Reheating/Recooling ystem o ystems seniln a room have 10,000 CF PPIr No Section 1432.4 DDC Required With Trending and Demand Response Yes. Yes. Section 1436.2 Condensate Recovery Required Section 1438.4 Refrigeration Condenser Heat Recovery Required Yes-► Section 1438.3 Controls Must Reduce Airflow When System In Not Heating or Cooling Fan or Pump Motors >= 7.5 HP? Section 1438 Variable Flow Devices Required otor Incl. In Eqpmt. Covr'd by Tbl 14 -1A -14- 1G? Multi -speed Motor In Multi eed system Yes* Section 1432.2.2 Water Temperature Reset Required No-* Section 1437 Motors Must Meet Efficiencies in Table 14-4 Yes otal Bld.. Laboratory Exhaust> 5,000 cfm? DONE Section 1439.1 No Heating or Cooling For at Least 50% of Make-up Alr Yes 110. Section 1439.2 Ona Required: a. Heat Recovery per 1439.2 b. 50% VAV Exhaust & Make-up c. 75% Direct Makeup w/ Tempering Only d. Combined Energy Reduction Qer>=Amin Yes Yes .4 2009 Washington State Energy Code Compliance Forms for Nonresidential. and MultifamiiyResidential Economizer Forms for Nonresidential and Multifamily Residential MECH-ECO Revised February 2011 2009 Washington State Energy Code Compliance Economizer Summary Check box(es) for exceptions being claimed. List the system/equipment that qualifies for each exception. See Section 1433 for full description of Economizer requirements. J Full Air Econo: ❑ Ex 1: ❑ Ex 5: ❑ Ex 9a: 0 Ex 2: ❑ Ex 6: 0 Ex 9b: ❑ Ex 3: ❑ Ex 7: ❑ Ex 9c: Ex 4: 0 Ex 10: Decision Flowchart Use this flowchart to determine if project Aplies with Economizer requirements. If not, the Systems Analysis Option must be used. 100% Air conomizer Yes Reference Section 1433 hied un F .m Table 14-1A, / EER 15% ode S No Group R Occ. xception 8: Unit Cap <20,000 Bluh Yes Yes Full Air Economizer- Complies xception Cap < 33,000 Bt nit not Exterior o djacen Idg. Cap. w/o economizer <72,000'Btuh or 5%? ception t Cap <54,000 B t not Exterior ace Exception 2: Chilled Water Sys. ' er 25% over eptio er Cooled Re . . aterstde Economize "ng chilled b= Sys xception 3 Syste Cap. <g500tons Yes No No 14 1 o. Exception 4: Cooling 75% Site HR or Solar Exception 5: Special OA titration Need ception .: Dehumidification Yes' with supporting rgy anal Exception 7: Heat Pump Loop sting All Crit.. No No xception 9: Dedicated Server or Eq Rm erved b 14-1A or 14-1B. qulpme Yes— Lo ote C orbett cap>85,00 atu ception 10: RF System Meeting All Criteria No Does Not Comply I No Yes Qualifies for Full Air Economizer Exception - Complies 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Electric Motors MECH-MOT 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February2011 Project Address17501 Southcenter Parkway Date 5/21/2013 Complete the following for all design & B squirrel -cage, T -frame Induction permanently wired polyphase motors of 1 hp or more having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the, exceptions below applies). For Building Department Use Motor No. or Location HP Type (open/closed) Description of Application or Use Synch. Speed Min.Nom. Full load Efficiency 154nirnirr Norririal Full -Load Efficiencies (%) As of 1211912010 Exceptions: 1. Motors In systems designed to use more than one speed of a multi -speed motor. 2. Motors already Included In the efficiency requirements for HVAC equipment (Tables 14- lA or 14-i13). 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (I.e. equipment which requires a special motor, such as an explosion- proof motor). 4. Motors Integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. If the only U.L. listing for the equipment is with a less -efficient motor and there is no energy-efficient motor option). For motors claiming an exception, list motor and note which exception applies. Open Motors Enclosed Motors Synchronous Speed (RPM) 3,600 1,800 1,200 3,600 1,800 1200 Motor HP 1.0 77.0 65.5 82.5 77.0 85:5 82.5 1.5 84.0 86.5 86.5 84.0 86.5 87,5 2.0 855 86.5 87.5 85.5 66.5 88,5 3.0. 85.5 89.5 88.5 86.5 89.5 ,5 5.0 86.5 89.5 89.5 88.5 89.5 5 7.5 88:5 91.0 90.2 89.5 91.7 91.0 10.0 89.5 91.7 91.7 90.2 9L7 91.0 15.0 90.2 93.0 91.7 91.0 92.4 91.7 20.0 91:0 93.0 02:4 91.0 93.0 91.7 25.0 91.7 93.6 93.0 91.7 93.6 93.0, 30.0 91.7 94.1 93.6 91.7 93.6 93.0 40.0 92.4 94.1 94.1 92.4 94.1 94:1 50.0 93:0 94.5 94.1 93.0 94.5 94.1 60.0 93.6 95.0 94.5 93:6 95.0 94.5 75.0 93.6 95.0 94.5 93.6 95.4 95.4 100.0 93.6 95.4 95.0 94.1 95.4 95.0 125.0 94.1 95.4 95.0 95.0 95.4 95.0 150.0 94.1 95.8 95.4 95.0 95.8 95.8 200.0 95.0 95.8 95.4 95.4 96.2 95:8 250.0 95.0 95.8 95.4 95.8 96.2 95.8 300.0 95.4 95.8 95.4 95.8 96.2 95.8 350.0 95.4 95.8 95.4 95.8 96.2 95.8 400.0 95.8 95.8 95.8 95.8 96.2 95.8 450.0 95.8 96:2 96.2 95.8 96.2 95.8 500.0 95.8 96.2 96.2 95.8 96.2 95.8 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential NigAlim@tiPermfRPOm@ffo Rt ' XE 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised February 2011 Project Address 17501 Southcenter Parkway (Date 5/21/2013 The following information Is necessary to check Washington State Nonresidential Energy Code. a mechanical permit application for compliance with the mechanical requirements in the Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes. HVAC REQUIREMENTS (Sections 1401-1424) 1411 Equipment Performance Yes 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M2.0 N.A. 1411.1 Combustion htg. Indicate intermittent ignition, flue/draft damper & Jacket loss N.A. 1411.1 Air-cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water-cooled chiller Full -load and NPLV values adjusted for any non-standard conditions N.A. 1411.4 Pkg. elec. htg.& cig. List heat pumps on schedule N.A. 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls N.A. 1412.1 Temperature zones Indicate locations on plans N.A. 1412.2 Deadband control Indicate 5 degree deadband minimum N.A. 1412.3 Humidity control Indicate humidistat N.A. 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback Yes 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage MO.0 Yes 1412.4.2 Optimum Start Indicate optimum start controls MO.0 N.A. 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule Yes 1412.6 Combustion heating Indicate modulating or staged control M2.0 N.A. 1412.7 Balancing Indicate balancing features on plans N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high -occupancy areas N.A. 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. Yee 1423 Thermostat interlock Indicate thermostat Interlock on plans M0.0 N.A. 1432.2.1 Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. Yes 1413.1 Air Econo Operation Indicate 100% capability on schedule M0.0 N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N.A. 1413.2 Wtr Econo Document Indicate max. OSA condition for design clg Toad & equipment performance data. Yes 1413.3 Integrated operation Indicate capability for partial cooling M0.0 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems N.A. 1414.1 Duct sealing Indicate duct design pressures, sealing, and testing requirements N.A. 1414.1.2 Low press. duct test Indicate applicable low pressure duct systems shall be leak tested N.A. 1414.1.3 High press. duct test Indicate high pressure duct systems shall be leak tested, and Identify the location of this ductwork on plans N.A. 1414.2 Duct Insulation Indicate R -value of insulation on duct 1415 Piping Systems N.A. 1415.1 Piping Insulation Indicate R -value of insulation on piping 1416 Completion Requirements N.A. 1416.3.2 System Balancing Indicate air and water system balancing requirements Yes 1416.3.3 Functional Testing Provide sequence of operations and test procedures. MO.0 Yes 1416.3.4 Documentation Indicate O&M manuals, record drawings, staff training MO.0 Yes 1416.3.5 Comm. Report Indicate requirements for final commissioning report MO.0 N.A. 1416.4 Compliance Chkiist Submit to building official upon substantial completion. Yes Mechanical Summary Form Completed and attached. Equipment schedule with types, input/output, efficiency, cfm, hp, economizer 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist Continued MECH-CHK 2009 Washington State Energy Code Compliance Fomes for Nonresidential and Multifamily, Residential Revised Febniery 2011 Project Address 17501 Southcenter Parkway (Date 5/21/2013 The following information is necessary to check a mechanical permit application for compliance with the mechanical requirements Washington State Nonresidential Energy Code. In the Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440-1454) 1440 Service water htg. N.A. 1441 Elec. water heater Indicate R-10 Insulation under tank N.A. 1442 Shut-off controls Indicate automatic shut-off of circulators or heat trace N.A. 1443 Pipe Insulation IndicateR-value of insulation on piping N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. 1460 Heated Pools N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R-12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction COLD STORAGE (Sections 1460-1465) 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensers Indicate condenser cooling type, design Wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" Is indicated for any item in Sections 1401-1424 or 1440-1465 , provide explanation: KIA Co per,'" 1802 W Lake Sammamish PKWY SE Bellevue, WA 98008 Phone: 425-644.-6400 Cell: 425-351-5999 TOYS R US #8002 MECHANICAL UNIT SUPPORTS (RTU -2, 5, 6, 7, 12) 17501 SOUTH CENTER PARKWAY TUKWILA, WASHINGTON 98188 FOR MERIT MECHANICAL, INC. STRUCTURAL CALCULATIONS APRIL 03, 2013 JOB NO: 106-1306 1EXp►RE$,/-zt-00J9j CORRECTION P'U3oB5 LTR# REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA MAY 2 4 2013 PERMIT CENTER 7 .G. C'i ) • i )4J) • .AWAwMaMINV i1� MUNCIE PJll/1r.MINPRIJldllNIf.I1..1111111111, .AM7riAMO P•JINIIIMili PARTIAL ROOF FRAMING PLAN 1) NOTES: ... CONTRACTOR TO VERIFY '2). CONTRACTOR TO VERIFY 3) CONTRACTOR TO VERIFY • ALL S1ZES, DIMENSIONS, AND LOCATIONS. AT FIELD, ALL 'EXISTING' ROOF FRAMING MEMBER: SIZES: MECHANICAL UNIT SIZE, WEIGHT AND LOCATION. 0 Project/SW] �� Jvsfi Sheet No. ) • '-3 J)3 J,�G-1yaJ 0.3.53 .. ) .: G• 1 • /...f/�....5•. �. T Z.; • v ProJeoUSubfect .7XJ1 &' $teaZ ...................................... .. 'l/,� v✓1/.4, ,,f• -- Sheet No. 24/ 0 f -3-)j Job No. • 1. i• L Y0. ...... .... PVt • Dale Slleet No, Job No. I ROOF LOADS: DEAD LOAD B.U. ROOFING MIL DECKING STEEL. TRUSS SPRINKLER • INSULATION • PURLIN 2.5 PSF 2:2 1.5 2 2 CEILING 0 MISC.1 MECH. SUB -IOTA •3:8 14 PSF LIVE LOAD: SNOW 25 PSF • TOTAL •LOAD: .39 PSF ECHANICAL UNIT DATA: • RTU 135316S (UNIT) + 2555. Ibs (ADAPT.. CURB) .• •RTU5 1280 ibS (UNIT) + 191 Ibs. (ADAPT. CURB) RTU =6 = 1353 lbs (UNIT) + 255 Ibs; (ADAPT. CURB) RTU ..7..= 1353 Ibs (UNIT) .+ 255 Ibs (ADAPT: CURB) RTU 12 = 1353 Ibs (UNIT) + 255 Ibs:(ADAPT. CURB) • yitiz v✓/k4 1 • By Sheet Date Job No. • G.// G/ ' 6 x /Jf` • /„ �'4r.G.. .-msec' 0 4 ��GGfr'; ,,.4E . 4/400' .:.......... • XJ !;ti-�' l6g • • 454 .7,7k . . A. <... 44,31pt > ) G Project/Subject By Shaet.No. - ./z/ Job No. ' /v�-l3 aG • 1j` , ..ter 7.-41•/i s% C u g • Z 141 f✓dv/Dd (1 4-ig .GGg. ii$ ' 752...iKki , �.. ,.?). 4-7x fi-f 160' / lfr Prolooraublea tel/ 1,w -A .,?d sheet �. 'z1 Date 04 3-)3 Job NO. • • 4J 175>�g..,.:.� 1 ............. �.1..,Z.Z 1 Jr" /1.ft dI-✓��; f .3134 0.g�a c 7.9 4',i +e , 0 0 PrO]oot/S ib`ect By A 'NM) Job No. .LATERAL.BESIGN:.(l.B.C. 2009.,.ASCE .7..-05).. 1A WINn- BASIC WIND SPEER (RTU -2, 6, 7, 12) .85 MPH. . (FIG... 6-1,. ASCE 7-05) • EXP.. '6" • Iw = 1 Kc# = . 0 0 g (TABLE 6-4; ASCE 7-05) • • Kz Kzt= 0 7 10 UP TO 30' .(FIGURE 6 4, ASCE 7-05). Gf 0:$5 '(GUST FACTOR) qz = 0.00256 qz = 1 .7 F. _. . Cf x Kz x Kzt'x KiTix V"2 x I PSF 1.3 (FlG. 6-21 .. (EQ . 6-15) ASCE -05, FOR MECHANICAL UNIT) qz x Gf x.Cf XA 12.88 'M. UNIT LENGTH UNIT WIDTH UNIT HIGHT (L) .FT EQ, 6-28).......... W) (H)= 5 4.0 • FT FT SHORT DIRECTION: F wind = 438 lbs LONG DIRECTION ..:.F wind =..... 258. Ibs 0 a Project/Subject By + Sheet No,� Date Job No, TOYS R US, TUKWILA MCE Ground Motion - Conterminous 48 States Zip Code - 98188 Central Latitude = 47.447736 Central Longitude = -122.273462 Period MCE Sa (sec) (%g) 0.2 133.7 MCE Value of Ss, Site Class B 1.0 046.0 MCE Value of S1, Site Class B Spectral Parameters for Site Class D 0.2 133.7 Sa = FaSs, Fa = 1.00 1.0 070.8 Sa = FvS1, Fv = 1.54 Spectrum for Site Class D Period MCE Sa (sec) (%g) 0.000 053.5 T = 0.0, Sa = 0.4FaSs 0.106 133.7 T = To, Sa = FaSs 0.200 133.7 T = 0.2, Sa = FaSs 0.529 133.7 T = Ts, Sa = FaSs 0.600 118.0 0.700 101.1 0.800 088.5 0.900 078.6 1.000 070.8 T = 1.0, Sa = FvS1 1.100 064.3 1.200 059.0 1.300 054.4 1.400 050.6 1.500 047.2 1.600 044.2 1.700 041.6 1.800 039.3 1.900 037.3 2.000 035.4 • • • SEISMIC (2009 IBC) RTU..2; 6, 7;12) ZIP COOE: 8188 LATITUDE = 47.4477 LONGITUDE 122:273• Ss•i-- S1 r 1337'g 0.46 g SITE CLASS "C' • • $DC Fa = Fv 1.5! Sms .Fa.ic Ss = 1.34g..; Sm1 = Fv x S1 :... 0.71' g.. Sds— 2/3 Stns j 0.89 g Sd1 2/3 Sm1 = F = (0.4 Ap.Sds.Wp/(Rp/I.p)) Ap�:......2.5 0.47 g (1 + 2 Z/H) EQ. 1.3.3-1) • Ip 1 Rp = 6 Sds = . 089 • ProJecVSebject By /1 Date Sheet N1/ / z Job No.• 1 a�'J3o� ZJH = Wp = i.FP = 603 •Ibs 353 lbs Fp -MAX)( - .6 Sds:Ip.Wp= 1,930 lbs >•F -•O.K '••• Fp (MIN) = 0.3 Sds.Ip. Wp = .362 Ibs < Fp O.K. Fp (ASD) = p/1.4 431 Ibs • (WIND GQVERNS IN SHORT DIRECTION) CHECK•UN]T•STABILITY: • SHORT DIRECTION' • F(WIND)= 430 Ibs MNl (0;T.) M(R•) = •• 0:6.M.(R)=-• . .876 . Ibs-ft • 3383 Ibs-ft 2030 •Ibs-ft • U.S.ING:.MIN.IMUM .(4)-#1 (wind) 7#12 SCREW= > M (O.T:) :........ NO UPLIFT, 2.SGREWS EACH SIDE THE UNIT / CURB 55 Ibs -.O.K. ProJecUHub(ect Date Job No. .LATERAL .DESIGN (I.B.0 2009,. ASCE .7.05). (A) WIND— 6ASIC.WIND .SPED (FTU -5)' 85.MPH FIG. 6 - , ASCE 7-05) • EXP. iw B" 1.0 Kd. 0.9... (TABLE 6.4; ASCE 7-05) Kz: = Kz1= 0.7 1 0 UP TO 30' (FIGURE 64, ASCE.7.-05) Gf 0.05 • '(GUST FACTOR)' qz = 0.00256 .......................... qz= 11.7 x Kz x Kzf 'x Kd -XV .2 x PSF (EQ. 645) Cf 1.$ (FIG. 6-21, ASCE 7-05, FOR MECHANICAL UNIT). F= zx Gf xCfx Af (EQ. .6-28)...... F'= 12.88 'A UNIT LENGTH UNIT UVIDTH UNIT HIGHT (L) 8:5 H) _.... 5 4.0.. FT FT SHORT DIRECTION: F wind 438 Ibs LONG DIRECTION • F.wind=- 258 lbs • By Gi + Sheet i , ,�7�/Z / Derr Job No.• • SEISMIC (2009 IBC) •ZIP CODE: (RTU. 5) 98188 • LATIT DE = LONGITUDE Ss S1 47.-4477 122.273 . 1.337. g.... ............... 0.46 g • SITE CLASS SSC SDC D. Fa = Fv Sms Sm1 =.Fa.x.Ss =F.vx Si= . Sds = 2/3 Sills 1.34 0.71 0.89 9 g 9 Sdl =2/3SIn1,• Fp = (0.4 Ap.Sds.Wp/(Rp/I p)) Ap 2. 0.47 (1 + 2 Z/H) • • • (EQ 1.3. Ip Rp Sds•= • ProiecUsubjoct • 0.8 By04 Sheet No. Date Job No. -3-15 ��/-))'OI ZJH •=• • • Wp 1280 lb Fp = 570•Ibs • • Fp (MAX) - Fp (MIN) = Fp (ASO) = 6 Sds.Ip.Wp .3 Sds.lp.V1(p = 1,825 Ibs > Fp O.K. 342 Ibs < Fp O.K. Fp / 1.4 = 407 Ibs (WIND GOVERNS IN SHORT DI RECTION) CHECK UNIT STABILITY: • SHORT DIRECTION: ....... F(WIND)= ...438.lbs ....... . M (O.T.) = 876 lbs -ft M(>) = 3200lbs-ft 0.6 M (R)= 1920.1b -ft •M (O ...... ..USING...MINIMUM (4)-#12 SCREWS F(wind)'/#12' SCREW='• • 55 T.)........ NO UPLIFT EACH.SIDE OF. THE UNIT /.CURB •Ibs 0.R. • • -)4 Project/Subject geocli By Shoot NO I Oate Job No. APPENDIX Lennox Industries Inc. - Product Submittal System ID: RTU -2,6,7,12 Package Model: LGHI20H4M Description: PKGGE/10TON/CONFIGURABLE DATING PERFORMANCE Heat Source H/E LowInput H/E LowOutput H/E HighInput H/E HighOutput System HeatOutput Natural Gas Gas Supply Connection 156000 (Btuh) HB Heat Rise 125000 (Btuh) AFUE/ ThermalEff 240000 ()Ruh) Number of Heating Stages 192000 (Btuh) Gas Supply Pressure 192000 (Btuh) 0.75 (in.) 44.4 (°F) 80 2 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI LEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCool Coil GrossSensCool Coil NetSensCool Tube/Fin Refrigerant Charge R -410A Number Compressors 12.0 Number of Cooling Stages 13.8 Condensate Drain Size 9900 (W) Cooling OutdoorDB 122000 (Btuh) Cooling MixedDB 118000 (Btuh) Cooling MixedWB 124400 (Btuh) Coil DischargeDB 117641 (Btuh) Coil DischargeWB 89568 (Btuh) Unit DischargeDB 82809 (Btuh) Unit DischargeWB 28 LBS. 0 OZ. Coil MoistureRemoval System MoistRemoval SUPPLY FAN PERFORMANCE 2 1.00 (in,) 95.0 (°F) 80.0 (°F) 67.0 (°F) 58,0 (°F) 56.6 (°F) 59.7 (°F) 57.3 (°F) 32.8 (lb/lor) 32.8 (1b/hr) Supply Fan Total Air Flow Supply AirFlow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 4000 (cfm) 4000 (cfm) 0.60 (in.WC) 2.26 (hp) 3.00 (hp) MSAV Belt Drive 930 (rpm) 730 (rpm) 970 (rpm) TotalStaticPress Wet Coil Static Press Gas H/E Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness ELECTRICAL 1.20 (in.WC) 0.15 (in.WC) 0.22 (in.WC) 0.04 (in.WC) 0.19 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) Voltage Frequency System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 26.0 (amp) 30 (amp) 16.0 (amp) 23.4 (amp) +1- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 4.8 (amp) 2.6 (amp) 725 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 1353 (lb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in) 24.0 (in.) 27.0 (in.) SOUND Outdoor Sound Rating 88 (db) Project: 3000313448 TOYS R US 118002 Quote: 4000382068 TOYS R US 118002 Page 3of13 Last Changed: MIKE W. JOHNSTON Prepared On: 2012-12-17 Phone: 972-497-6884 IS/ Lennox Industries Inc. - Product Submittal System 1D: RTU -2,6,7,12 Package Model: LGH120114M Description: PKGGE/10TON/CONFIGURABLE DIMENSIONS - INCHES (MM Model No. CORNER WEIGHTS CENTER OF GRAVITY AA B8 CC 00 EE FF Baso Max. wag Max. Moo Max. Base Max. Base Max. Base Max. lbs. kg lbs. kg lbs. kg_Ibs. kg tbs. 4 lbs. kg lbs. kg lbs. kg In. mm In. mm in. mm In. nun 092 293 133 338 153 283 119 295 134 288 130 316 143 328 148 370 188 46.5 1181 45.6 1168 24.6 822 25.5 648 102 204 134 340 154 286 120 297 135 288 131 318 144 328 149 372 189 46.6 1181 45.6 1168 24.6 822 25.5 648 120 308 139 349 168 275 125 305 138 296 134 326 148 334 162 382 173 48.6 1181 45.5 1158 24.6 622 25.5 648 150 316 143 359 163 284 128 314 142 304 138 393 178 345 157 393 178 46.6 1181 46,5 1166 24.5 622 25.6 648 Bass (hilt • the tint w9h NO NTERNA).OPrIONS. Pier. Unit-ThountwithALLI?6tBWOPTIONShstekd(Eoonantw;StadrdStottsP0varDfioudFans.Codrds,aa).Duesn0t:lekdsanneswilesea matb utit of h I3 h static gymtr e5fie ust r se -116 (1470) O ooj amM (1627) (69) ENO VIEW Project: 3000313446 TOYS R US 48002 Quote: 4000382068 TOYS R US 1'8002 Page 5 of 13 6.415 (166) 6.53! 5071014 SUPPLY 043)0071091OPEION0 26 20 PM (�1 6048(1524 I 1:0/1 MIT CASE / C11AV1TY BOTTa61aCTUt(N 1to7TOft AIRO RETURN POWER ENTRY 5-I0(140)Oa. �� a £E 12,10 •i FF (t66) �\ } }1:)7Ote) } CHe PE) garrom Jcc 101.1)4 865E s (2611) TOP VIEW (l0 mecum FILETS 964)1 OPTIOL D19CC6VNECr (2571) Ni FACTORY MULLED) YI — .4... ' CONDetLiATE CR It1 FRONT) 63'4 (tit/ ' OT 14 U. rawly % If�r FLUE Er / (475) 1au 3(-719 �,-,- (81.6) 39116 4 (1013)-1' FORICTFT SLOTS OWN SIDES) (10111.03G1Nsl -r 464)6 p 91) i 34//2 0646 (1666) SIDE VIEW (Nod:ontal Openings) Last Changed: MIKE W. JOHNSTON Prepared On: 2012-12-17 Phone: 972-497-6884 Lennon Industries Inc. - Product Submittal System ID: RTU -5 Package Model: LGH092H4M Description: PKGGE/7.5TON/CONFIGURABLE HEATING PERFORMANCE Heat Source WE Lowlnput H/E LowOutput H/E HighInput H/E HighOutput System HeatOutput Natural Gas 117000 (Btuh) 93500 (Btuh) 180000 (Btuh) 144000 (Btuh) •144000 (Btuh) Gas Supply Connection H/E Heat Rise AFUE/ ThermalEff Number of Heating Stages Gas Supply Pressure 0,75 (in.) 44.4 (°F) 80 2 7 (in.WC) COOLING PERFORMANCE Refrigerant ARI EER ARI IEER ARI Total Power ARI GrossTotalCool ARI NetTotalCool Coil GrossTotalCool Coil NetTotalCoot Coil GrossSensCool Coil NetSensCool Tube/Fin Refrigerant Charge R -410A 12.5 14.0 7500 (W) 93000 (Btuh) 90000 (Btuh) 93000 (Btuh) 89064 (Btuh) 67890 (Btuh) 63954 (Btuh) 26 LBS. 0 OZ. Number Compressors Number of Cooling Stages Condensate Drain Size Cooling OutdoorDB Cooling MixedDB Cooling MixedWB Coil DischargeDB Coil DischargeWB Unit DischargeDB Unit DischargeWB Coil MoistureRemoval System MoistRemoval 2 2 1.00 (in.) 95.0 (°F) 80.0 (°F) 67.0 (°F) 57.7 (°F) 56.6 (°F) 59.0 (°F) 57.1 (°F) 23.7 (lb/hr) 23.7 (1b/hr) SUPPLY FAN PERFORMANCE Supply Fan Total Air Flow Supply Airflow ExtStaticPress Supply SupplyFan Req'dPower SupplyFan NomPower Supply Fan Type SupplyDriveReq'd RPM SupplyDrive Min RPM SupplyDrive Max RPM 3000 (cfm) 3000 (cfm) 0.60 (in.WC) 1,32 (hp) 2.00 (hp) MSAV Belt Drive 813 (rpm) 590 (rpm) 890 (rpm) TotalStaticPress Wet Coit Static Press Gas HIE Static Press Added Filter Static Press Economizer Static Press Air Filter Qty Air Filter Length Air Filter Width Air Filter Thickness 0.97 (in.WC) 0.10 (in.WC) 0.12 (in.WC) 0.02 (in.WC) 0.13 (in.WC) 4 20.0 (in.) 25.0 (in.) 2.0 (in.) ELECTRICAL Voltage Frequenoy System MCA System MOCP Compressors RLA Cooling FLA Total Unit Oper Range -Nom Voltage 460V 3Ph 60 (Hz) 20.0 (amp) 25 (amp) 12.2 (amp) 18,2 (amp) +1- 10% SupplyFan FLA CondensingUnit FLA CondenserFan Power 3.4 (amp) 2.6 (amp) 725 (W) DIMENSIONS Cabinet Width Cabinet Length Cabinet Height Total Weight 60.1 (in.) 101.3 (in.) 46.9 (in.) 1280 pb) Downflow Supply Length Downflow Supply Width Downflow Return Length Downflow Return Width 20.0 (in.) 28.0 (in.) 24.0 (in,) 27.0 (in.) SOUND Outdoor Sound Rating 88 (db) Project: 3000313446 TOYS R US 118002 Quote: 4000382068 TOYS R US 918002 Page B of 13 Last Changed: MIKE W. JOHNSTON Prepared On: 2012-12.17 Phone: 972-497-6884 Lennox Industries Inc. - Product Submittal System ID: RTU -5 Package Model: LGH092H4M Description: PKGGE/7.5TON/CONFIGURABLE DIMENSIONS - INCHES (MM) Model No. CORNER WEIGHTS CENTER OF GRAVITY AA 8B CC DD E6 FF Base Max. Base Max. Base Max. Base Max. Base Max. Base Max. lbs. k9 Ibs. kg lbs. kg lbs, kg Ibs. kg lbs. kg Ibs. kg Ibs. kg In. mm In. mm In. mm M. mm 092 293 133 338 163 283 119 295 134 288 130 316 143 326 148 370 188 48.5 1181 45.5 1156 24.5 622 26.6 648 102 294 134 340 154 265 120 297 135 288 131 318 144 328 140 372 160 46.6 1181 45.5 1156 24.6 622 26.5 648 120 306 139 349 156 276 125 305 138 296 134 328 148 334 152 382 173 48.6 1181 46.6 1166 24.5 622 26.6 648 150 318 143 359 103 284 129 314 142 304 138 393 178 346 167 393 178 46.6 1181 45.5 1166 24.5 622 26.6 648 BMA Mit • The Lie! will H0NTERNALOPTIONS. Max Link •TheunlwithAll INTERNAL OPTIONS hltated (Eeonanael StandardSwUcPaaar Exhaust Fans. Cart (seeks). nom notix)udeaccei a oocatemalb argot hgh state power adaauit. 05.119 (1470) 100 t"'T i=1 00 OW) END VIM Project: 3000313446 TOYS R US #8002 Quote: 4000382068 TOYS R US 88002 Page 10 of 13 t 45.74 0991) 6•lIA (1� SIU BOTTOM 6UPRY �AIROPEDal1 G116 t15b)i e0.140SA) OASE *0710]3 OWAER ENTRY 5.1811(6) PA tea 2A 1273) an 1711) CENTER OF 4et GRAYRY 9012061 RE7t1TN ir AIR OM WO r• FF 6JJ8- -'4 7(170) 'f' (168) I\ ThP 7 (978) 34-74_ OM) 88 comzusars eorrosi jcn 16/•1N EABE (7332) TOP VIEW 29.1/4 OPTIONAL 013CONNEOT 12521) (FACTORY INSTALLED) 0404840 914.810 40-118 (1 91) •`34-701 (9661 FORKLIFT SLOTS LIFTING pxnHbxle3) (FORla0WN0) Es 34770 (1016 101.1/ (2572) SIDE VIEW SIDE VIEW (Horizontal Openings) Last Changed: MIKE W. JOHNSTON Prepared On: 2012-12-17 Phone: 872.497-6884 Job Name: TRU#8002 - SEATTLE. WA Drawing Date: 1-29-04 REV: 002 6-9-05 Approved By: SHELL:16 GA. PANS:18 GA. CHANNELS:18 GA. CLOSURES: 16 GA. TOP FLANGE DIM: 1 1/2" � / „//' ///'/ 1 / // / / / / / // / /0 / / __— y____ - N CO m /' S/A RIAN m to - / P r 7}� 94314"O.D. / /- 1" 58 318" 35 318" r e`er o „i ---' i . -- r 6" 1715116" 29116" / 31 112" 4" 32 314" -- QTY.• 1 DRAWN BY.: SLW NEW UNIT: LENNOX 88314"BASE . LGH092 �� e, j ° { ; -_ _ ' :. OLtis Ilii TRANSITION -CURB SYSTEM OLD UNIT: LENNOX J 1200 Canine Rd. Conidenftal and propriety information of curbs Plus, Inc. unauthorized use, disclosure, or reproduction is expressly prohibited. GCS24-953 RossviPhonelle, G6) 58-113074TAG PLATE:LX9LX87 / LX296LX87 Phone:(706) 858-11881 Fax: (706) 866-2339 ROLLS OF GASKET:2 website: www.curbs-plus.com APPROXIMATE WEIGHT:191 LBS. * TAG: RTU -5 ote: Design subject to change without notice. File Name: LX9LX87 NEW LENNOX L -SERIES 090-150 EXISTING LENNOX GCS16-953 ©2003 Curbs Plus, Inc. Job Name: TRU#8002 - SEATTLE, WA Drawing Date: 1-29-04 I REV: 003 3-9-11 I Approved By: SHELL: 16 GA. PANS:18 GA. CHANNELS:18 GA. CLOSURES: 16 GA. 1 TOP FLANGE DIM; 1 1/2" m M /, '/ ' R / ,/ :/' /I ' / to c, I SIA ' ���_ --,L____1�. V O 6 in 1 cn N m fl r r T—.���� ! 93314"O.D. 1° 57 7!8° 34 718" is M r- �� QT(.; 4 DRAWN BY.: SLW — 25114° —1,--- 311/2° 3111a° 2911x" 33116° NEW UNIT: LENNOX 33 314° BASE LGH120 Iii; T•1111 -:OLD :�� �� , �� TRANSITION -CURB SYSTEM UNIT: LENNOX � 1200 Canine Rd. Confidential and propriety Wonders alCurbs Sus. Eno unauthorized use. dt'd •ar rcproauwontsexpresslypron>bto d. GCS24-1353 RossAlle, GA 30741 Phone:(706) 858-1188 / Fax: (706) 866-2339 TAG PLATE: LX9LX80 / LX296LX80 ROLLS OF GASKET:1 website: www.curbs-plus.com APPROXIMATE WEIGHT:255 LBS.* TAG: RTU -2,6,7,12 File Name: LX9LX80 NEW LENNOX 1 -SERIES 090-150 EXISTING LENNOX GCS16-1353 ©2003 Curbs Plus, Inc. May 15, 2013 Michael Atwood Merit Mechanical 9630 153 Av NE Redmond, WA 98052 • City of Tukwila • Jim Haggerton, Mayor Department of Community ty Development Jack Pace, Director RE: Correction Letter #1 Mechanical Permit Application Number M13-088 Toys -R -Us —17500 Southcenter Py Dear Mr. Atwood, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson at 206 431-3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, '--44(1e Bill Rambo Permit Technician File No. M13-088 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: May 13, 2013 Project Name: Toys -R -Us Permit # M13-088 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36. Please submit all plans on the same size paper. Revised plans need to be the same size as originally submitted). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Please verify that the new units are lighter than the old units and located in the same place. If not, provide structural approval as stated in the general notes on the cover page. Documents will need to be stamped by a structural engineer licensed in the state of Washington. 2. Please complete a Washington State Energy Code Mechanical Summary form. One has been included with this review memo. Should there be questions concerning the above information please contact the Building Division at 206-431-3670. ?EMIT COORD COPY. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-088 DATE: 05-24-13 PROJECT NAME: TOYS -R -US SITE ADDRESS: 17500 SOUTHCENTER PY Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued DEPARTMENTS. Building Division Public Works n Fire Prevention n Planning Division Structural ❑ Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 05-28-13 Complete Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use'OnIj? ` INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06-25-13 Approved n Approved with Conditions 156 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: P milt: enter+Use'On/y CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 *PERMIT COORD COP. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-088 DATE: 05/08/13 PROJECT NAME: TOYS -R -US SITE ADDRESS: 17500 SOUTHCENTER PY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: B'uiLdin Ivlslon Public Works Awe, s--111-13 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 05/09/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route -T-" REVIEWER'S INITIALS: Structural Review Required ❑ No further Review Required ❑ DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) Oil Notation: REVIEWER'S INITIALS: DUE DATE: 06/06/13 DATE: Permit Center Use Only CORRECTION LETTER MAILED: ' ► 5 —1 Departments issued corrections: Bldg - Fire 0 Ping 0 PW 0 Staff Initials: VW� City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http://www.TukwilaWA.gov Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 06/17/2013 Plan Check/Permit Number: M13-088 Response to Incomplete Letter # Response to Correction Letter # ,/ Revision # after Permit is Issued Revision requested by a City Building Inspector or Plans Examiner Project Name: Toys -R -Us Project Address: 17501 Southcenter Parkway Contact Person: Michael Atwood Phone Number: (425) 883-9224 Summary of Revision: Permit lists address as being at 17500 Southcenter Parkway under parcel number 2623049110. Please revise address to 17501 Southcenter Parkway under parcel number 2623049067 ^rr V D JUN 17 2013 ca t'ERMir CENTER Sheet Number(s): "Cloud" or highlight all areas of revision including date of revision Received at the City of Tukwila Permit Center by: Entered in Permits Plus on ? H:\Applications\Forms-Applications On Line\2010 Applications\7-2010 - Revision Submtttal.doc Revised: May 2011 City of Tukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wn.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: 05-21-2013 Plan Check/Permit Number: M13-088 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: Toys -R -Us Project Address: 17500 Southcenter Py Contact Person: Van Duong Phone Number: 425-883-9224 Extension 1219 Summary of Revision: Note is added to equipment schedule on M2.0. CT+{v RECEIVED L4AV A '(11 1 PERMIT CENTER Sheet Number(s): 1 "Cloud" or highlight all areas of revision including date of rev ion Received at the City of Tukwila Permit Center by: )2-- Entered in Permits Plus on \applications\tomo-applications on line\revision submittal Created: 8-13.2004 Revised: Contractors or Tradespeople Peer Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MERIT MECHANICAL INC UBI No. 600517946 Phone 4258839224 Status Active Address 9630 153Rd Avenue Ne License No. MERITMI163CM Suite/Apt. License Type Construction Contractor City Redmond Effective Date 2/14/1984 State WA Expiration Date 6/1/2015 Zip 98052 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status AUTOMMC044QH AUTOMATED MECH CONTROLS INC Construction Contractor General Unused 11/8/1996 6/1/2010 Expired Business Owner Information Name Role Effective Date Expiration Date KIRKWOOD, RODERICK V President 02/14/1984 Bond Amount KIRKWOOD, JOAN M Secretary 02/27/2006 08358695 FRICKBERG, WILLIAM MICHAEL Vice President 02/27/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 10 FIDELITY Et DEPOSIT CO OF MD 08358695 02/01/2010 Until Cancelled $12,000.00 01/20/2010 9 ARCH INS CO SU1041124 02/01/2009 Until Cancelled 02/01/2010 $12,000.0001/12/2009 10/25/2011 8 TRAVELERS CAS SURETY CO 081S103546895BCM 07/22/2001 Until Cancelled 02/01/2009 $12,000.0003/07/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 28 Travelers Property Cas Ins Co VTC2JC0828K6148TIL12 11/01/2012 11/01/2013 $2,000,000.00 10/22/2012 27 Travelers Property Cas Co of A VTC2JC0828K6148TILL1 11/01/2011 11/01/2012 $2,000,000.00 10/25/2011 26 CEOXINGTONINS 014180670 11/01/2010 11/01/2011 $2,000,000.0010/29/2010 25 LEXINGTON INS 049159165 11/01/2009 11/01/2010 $2,000,000.00 11/02/2009 24 LEXINGTON INS CO 004052434 11/01/2008 11/01/2009 $2,000,000.00 11/04/2008 23 NSEE AMERICAN HD0G23734941 03/03/2008 03/03/2009 $2,000,000.0003/10/2008 22 CONTINENTAL WESTERN INS CO CWP2545786 11/01/2007 11/01/2008 $1,000,000.00 10/31/2007 https://fortress.wa.gov/lni/bbip/Print.aspx 06/14/2013 HVAC -LEGEND CODE COMPLIANCE NOTES RG - 100 CD - 100 EG 100 AIR FLOW DIRECTION SUPPLY OR OSA DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION UP OR TOWARD ROUND, RECTANGULAR SUPPLY OR OSA DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR RETURN, RELIEF OR EXHAUST DUCT SECTION DOWN OR AWAY ROUND, RECTANGULAR RETURN AIR, NUMBER INDICATES CFM QUANTITY SUPPLY AIR, NUMBER INDICATES CFM QUANTITY EXHAUST AIR, NUMBER INDICATES CFM QUANTITY SLSM SOUND LINED SHEET METAL VICINITY MAP MOTORIZED AND GRAVITY DAMPERS SHALL BE PROVIDED AS REQUIRED BY 2009 WSEC SECTION 1412.4.1, INCLUDING MAXIMUM LEAKAGE RATES WHEN TESTED IN ACCORDANCE WITH AMCA 500 OF 10 CFM/SF OF DAMPER AREA AT 1 INCH WG FOR MOTORIZED DAMPERS AND 20 CFM/SF OF DAMPER AREA AT 1 INCH WG FOR NON -MOTORIZED DAMPERS EQUAL TO OR LARGER THAN 24 INCHES IN EITHER DIMENSION AND 40 CFM/SF OF DAMPER AREA AT 1 INCH WG FOR NON -MOTORIZED DAMPERS SMALLER THAN 24 INCHES IN EITHER DIMENSION. CONTROLS SHALL BE CAPABLE OF PROVIDING OPTIMUM SYSTEM STARTUP AS REQUIRED BY 2009 WSEC SECTION 1412.4.2. AIRSIDE ECONOMIZERS SHALL BE USED AS A FIRST STAGE OF COOLING AND SHALL BE CAPABLE OF PROVIDING FULL OR PARTIAL COOLING CAPACITY DEPENDING ON THE COOLING DEMAND AND THE OUTSIDE AIR TEMPERATURE IN ACCORDANCE WITH 2009 WSEC SECTION 1413. HEATING AND COOLING SYSTEMS SHALL BE CONTROL INTERLOCKED TO PREVENT SIMULTANEOUS HEATING AND COOLING AS REQUIRED BY 2009 WSEC SECTION 1422. MAINTAIN 10'-0" MINIMUM DISTANCE BETWEEN OSA INTAKES AND PLUMBING VENTS, EXHAUST AND COMBUSTION AIR OUTLETS. GENERAL NOTES COMBINATION FIRE AND SMOKE DAMPER FIRE DAMPER SMOKE DAMPER VOLUME DAMPER. MOTORIZED DAMPER TURNING VANES ROUND TO ROUND 45' FITTING SQUARE TO SQUARE 45' FITTING SQUARE TO ROUND 45' FITTING 45' FITTING FOR DUCTWORK - GAS GAS - GAS PIPING COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. COORDINATE ALL NEW UNITS WITH STRUCTURE AND OTHER .TRADES. 2. HVAC EQUIPMENT WEIGHTS AND LOCATIONS TO BE APPROVED BY STRUCTURAL ENGINEER. 3. FIELD VERIFY UNIT LOCATIONS, DROPS AND POSITIONS. 4. SMOKE DETECTOR WIRE SHALL BE BY ELECTRICIAN; CONTROL SHALL BE BY FIRE AND LIFE SAFETY. 5. ALLLINE VOLTAGE WORK SHALL BE BY ELECTRICIAN. COMPLETION AND COMMISSIONING FOR MECHANICAL SYSTEMS RECORD DRAWINGS OF ACTUAL INSTALLATION SHALL BE PROVIDED TO THE BUILDING OWNER WITHIN 90 DAYS OF THE DATE OF SYSTEM ACCEPTANCE PER 2009 WASHINGTON STATE ENERGY CODE (WSEC) SECTION 1416.3.4. AN OPERATION AND MAINTENANCE MANUAL SHALL BE PROVIDED TO THE BUILDING OWNER PER 2009 WSEC SECTION 1416.3.4. N CD CO C13 ® . 7501 SOUTHCENTER PARKWAY TUKWILA WA, 98188 BUILDING INFORMATION HVAC CONTROL SYSTEMS SHALL BE TESTED, CALIBRATED AND ADJUSTED. SEQUENCES OF OPERATION SHALL BE TESTED TO ENSURE THAT THEY OPERATE IN ACCORDANCE WITH SPECIFICATIONS AND APPROVED PLANS, AND A COMPLETE REPORT OF TEST RESULTS SHALL BE FILED WITH THE OWNER PER 2009 WSEC SECTION 1416.3.3 AND 1416.3.5. ZONING: CONSTRUCTION TYPE: OCCUPANCY TYPE: TUC MASONRY. RETAIL TERMINAL UNIT r BUILDING OWNER ABBREVIATIONS GENERAL. - LEGEND 0 DIAMETER ABV ABOVE AD ACCESS DOOR AFF ABOVE FINISHED FLOOR AHU AIR HANDLING UNIT AP ACCESS PANEL BF BELOW FLOOR BFC BELOW FINISHED CEILING BOT BOTTOM CD CEILING DIFFUSER CFM CUBIC FEET PER MINUTE CG CEILING GRILLE CIP CAST IN PLACE CLG CEILING CONC CONCRETE CONN CONNECTION CTG CEILING TRANSFER GRILLE DB DRY BULB DIA DIAMETER DIFF DIFFUSER DN DOWN DWG DRAWING EA EACH EAT ENTERING AIR TEMPERATURE ENT ENTERING EQUIP EQUIPMENT ESP EXTERNAL STATIC PRESSURE EWT ENTERING WATER TEMPERATURE EXH EXHAUST FLR FLOOR FPM FEET PER MINUTE FT FOOT OR. FEET FUT FUTURE GALV GALVANIZED CR GRILLE HP HORSEPOWER HT HEIGHT TYP HVAC HEATING, VENTILATION AND AIR-CONDITIONING UNO HWG HIGH WALL GRILLE UPC HWR HEATING WATER RETURN VTR HWRR HEATING WATER REVERSE RETURN W HWS HEATING WATER SUPPLY W/ HWTG HIGH WALL TRANSFER GRILLE W/0 IBC INTERNATIONAL BUILDING CODE WB ID INSIDE DIAMETER/DIMENSION WG IE INVERT ELEVATION WSEC IMC.. INTERNATIONAL MECHANICAL CODE IN INCHES IN WG INCHES WATER GAUGE LBS POUNDS LIN DIFF LINEAR DIFFUSER LIN FT LINEAR FOOT OR FEET LWG LOW WALL GRILLE LWR LOW WALL REGISTER MAX MAXIMUM MBH 1000 BRITISH THERMAL UNITS PER HOUR MD MOTORIZED DAMPER MIN MINIMUM MTD MOUNTED NC NORMALLY CLOSED NO NORMALLY OPEN OR NUMBER OBD OPPOSED BLADE DAMPER OD OUTSIDE DIAMTER/DIMENSION OSA OUTSIDE AIR PCF POUNDS PER CUBIC FOOT PH PHASE POC POINT OF CONNECTION PSI POUNDS PER SQUARE INCH PSIG POUNDS PER SQUARE INCH GAUGE RA RETURN AIR REGISTER REQUIRED RELIEF AIR REDUCED PRESSURE BACKFLOW PREVENTER REVOLUTIONS PER MINUTE SUPPLY AIR SOUND LINED SMACNA SHEET METAL AND AIR-CONDITIONING CONTRACTORS' NATIONAL ASSOCIATION SQ FT SQUARE FOOT OR FEET SYM SYMBOL TDH TOTAL DYNAMIC HEAD TG TRANSFER GRILLE TOT TOTAL TYPICAL UNLESS NOTED OTHERWISE UNIFORM PLUMBING CODE VENT THROUGH ROOF WATTS OR WIDTH WITH WITHOUT WET BULB WATER GAUGE WASHINGTON STATE ENERGY CODE REG REQ'D RFA RPBP RPM SA SL CLPF-TUKWILA LP NEW EQUIPMENT, DUCTWORK, AND GRILLES EXISTING EQUIPMENT, DUCTWORK, AND GRILLES 111 1111111111111 FLEX DUCT EQUIPMENT TAG TAG TYPE �-Kw-EQUIPMENT TAG NUMBER ® -�--DETAIL OR DIAGRAM NUMBER -SHEET NUMBER WHERE DETAIL/DIAGRAM SHOWN 0- -' SECTION LETTER ®-SHEET NUMBER WHERE SECTION IS SHOWN c:2e) A REVISION CLOUD AND CHRONOLOGICAL NUMBER REVIEWED FOR COD COMPLIANCE APPROVED JUN 0 5 2013 AV- LEGAL DESCRIPTION POR SE 1/4 OF SW 1/4 SEC 26-23-04 & OF NE 1/4 OF NW 1/4 SEC 35-23-04 - BEG NE COR SD NE 1/4 OF NW 1/4 TH N 87-45-57 W 481.05 FT TO W MGN SOUTHCENTER PARKWAY TH S 11-59-33 E 41.27 FT TH N ` 87-45-57 W 210 FT TO TPOB TH CONTG N 87-45-57 W. 19.11 FT TH S 42-30-27 W 537.51 FT TAP ON A LN 19.5 FT SWLY OF C/L OF 19 FT WIDE RR ESMT TH NLY ALG A LN WCH IS CONCENTRIC & PLW SD C/L ALG CURVE TO RGT CENTER BEARING N 48-31-03 E RAD 429.78 FT ARC DIST 433.55 FT THRU C/A 57-47-52 TH CONTG ALG SD PLL LN N 16-18-55 E 50.03 FT TO S LN OF SD SEC 26 TH S 87-45-57 E 20.10 FT TO C/L EXISTING RR ESMT TH N 16-18-55 E 164.16 FT TH ALG CURVE TO RGT RAD 661.74 FT ARC DIST 184.73 FT THRU C/A 15-59-40 TH N 00-19-15 E 528.93 FT TH CONTG ALG SD C/L ON CURVE TO RGT RAD 410.28 FT ARC DIST 239.28 FT THRU C/A 33-24-54 TH S 88-51-25 E 34.64 FT TH S 01-08-35 W 198.66 FF TH N 86-40-03 E 274.13 FT TO W MGN SOUTHCENTER PARKWAY TH SLY ALG SD W MGN ON CURVE TO LFT CENTER BEARING N 85-13-08 E RAD 991.37 FT ARC DIST 40 FT THRU C/A 02-18-42 TH S 85-12-11 W 182 FT TH S 11-59-33 E 261.67 FT TH S 88-25-36 E 115.17 FT TH N 11-59-33 W 91.74 FT TH S 88-25-36 E 66.85 FT TO W MGN SOUTHCENTER PARKWAY TH S 11-59-33 E 531.16 FT TH N 87-45-57 W 210. FT TH . S 11-59-33 E 235.54 FT TO TPOB AKA PARCEL B OF CITY OF TUKWILA BOUNDARY LINE ADJUSTMENT NO BLA 8-79 RECORDING NO 7908230752. TAX PARCEL NUMBER: 262304-9067 MERIT MECHANICAL INC. 9630 153RD AVENUE NE REDMOND, WA 98073 24 FAX4 (425) 8867-0962 LICENSE: MERITMI163CM POINT OF CONNECTION TO EXISTING OR TO OTHERS' WORK OT THERMOSTAT REPLACE 5 EXISTING ROOFTOP GAS/ELECTRIC UNITS WITH OWNER PROVIDED NEW UNITS. REVISIONS 0. ISSUED FOR PERMIT 04-30-2013 1. ADDED NOTE 05-21-2013 V1D DESIGNED VTD CHECKED Film review approval is subled to errors and omissions. Apron! of construction &aunts cis not authorize the violation of any adopted axle or I -. Receipt of approved Feld 3.arui► , � ', ,x =et JH SEPARATE PERMIT REQUIRED FOR: O Mechanical ❑ Electrical ❑ Plumbing ❑ Gas Piping City of Tukwila BUILDING DIVISION 04-15-2013 JOB NUMBER. 813318 SHEET TITLE SHEET NUMBER REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. NOTE: Revisions will require a new plan submittal cnd may include additional plan review tes RECEIVED CITY OF TUKWILA MAY 2 4 2013 PERMIT CENTER CO BEHIND RTU -12 C; s` A.: sem,., .v.i c M c. EAST ELEVATION SCALE: 1/8" = 1'- d 4 .. d ZONING: LDR VACANT 726'=03 682'-04.6" ZONING: TUC 1 STORY ZONING: TUC 1 STORY ZONING: LDR VACANT RTU RTU 605'-6 " P01,4- 76'6CO4 49'-08" ZONING: TUC 1 STORY. ZONING: TUC 1 STORY LO C.0 N CO LO M 530'. 701' ZONING: LDR VACANT 726'-11$ ZONING: TUC 1 STORY ZONING: TUC 1 STORY REVIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION ZONING: TUC 1 STORY ZONING: TUC 1 STORY SITE PLAN SCALE: 1/64" = 1 M13 RECEIVED CITY OF TUKWILA MAY 2 4 2013 PERMIT CENTER COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. SOUTHCENTER PARKWAY O N CO CO 00 0) MERIT MECHANICAL INC. 9630 153RD AVENUE NE REDMOND, WA 98073 3-9224 FAX (425) $867 0962 LICENSE: MERITMI163CM REVISIONS 0. ISSUED FOR PERMIT 04-30-2013 1. ADDED NOTE 05-21-2013 VTD DESIGNED VTD CHECKED JH DATE 04-15-2013. JOB NUMBER 813318 SHEET TITLE SITE PLAN ELEVATION SHEET NUMBER M1.0 2-0F-3 RTU UNIT SCHEDULE TAG MAKE & MODEL DESCRIPTION CFM FAN NOISE COOLING, MBH HEATING, MBH ELECTRICAL WEIGHT REMARKS OSA SA ESP RPM HP DRIVE dBA TOTAL/SENS. EER/IEER IN/OUT AFUE VOLT PH MCA MOCP LBS RTU -2 LENNOX LGH120H4M 10 TON ROOFTOP GAS/ELECTRIC 600 4000 0.6 930 3.0 BELT 88 124.4/89.6 12.0/13.8 240/192 80 460 3 26.0 30 1608 1, 2, 3, 4 RTU -5 LENNOX LGH120H4M 10 TON ROOFTOP GAS/ELECTRIC 600 4000 0.6 930 3.0 BELT 88 124.4/89.6 12.0/13.8 240/192 80 460 3 26.0 30 1608 1, 2, 3, 4 RTU -6 LENNOX LGH120H4M 10 TON ROOFTOP GAS/ELECTRIC 600 4000 0.6 930 3.0 BELT 88 124.4/89.6 12.0/13.8 240/192 80 460 3 26.0 30 1608 1, 2, 3, 4 RTU -7 LENNOX LGH092H41vi 7.5 TON ROOFTOP GAS/ELECTRIC 450 3000 0.6 813 2.0 BELT 88 93.0/67.9 12.5/14.0 180/144 80 460 3 20.0 25 1471 1, 2, 3, 4 RTU -12 LENNOX LGH120H4M 10 TON ROOFTOP GAS/ELECTRIC 600 4000 0.6 930 3.0 BELT 88 124.4/89.6 12.0/13.8 240/192 80 460 3 26.0 30 1608 1, 2, 3, 4 NOTE: 1. EQUIPMENT MAY BES SUBSTITUTED FOR EQUAL OR BETTER MANUFACTURER 2. LOW/HIGH PRESSURE SWITCH, CRANKCASE HEATER, ADAPTER CURB, 3. SMOKE DETECTOR, ECONOMIZER WITH MOTORIZED RELIEF DAMPER. 4. OWNER PROVIDED UNIT. EXISTING UNIT EXISTING UNIT EXISTING UNIT EXISTING UNIT RE»dIEWED FOR CODE COMPLIANCE APPROVED JUN 0 5 2013 City of Tukwila BUILDING DIVISION EXISTING UNIT HVAC ROOF PLAN SCALE: 1n6" _ 1 - o RECEIVED CITY OF TUKWILA MAY242013 PERMIT CENTER COPYRIGHT NOTICE THIS LAYOUT/DESIGN IS AN UNPUBLISHED WORK, AND MERIT MECHANICAL HEREBY RESERVES ITS COMMON LAW RIGHT, PURSUANT TO TITLE 17 SECTION 2 OF THE USA CODE TO PREVENT ANY UNAUTHORIZED COPYING, PUBLICATION OR USE OF THIS DESIGN, AND TO OBTAIN DAMAGES THEREFORE. Q Ct co ( co 00 Et a) Z Q U 4 y 1- 0 N r MERIT MECHANICAL INC. 9630 153RD AVENUE NE REDMOND, WA 98073 (425) 883-9224 FAX (425) 867-0962 LICENSE: MERITMI163CM REVISIONS 0. ISSUED FOR PERMIT 04-30-2013 1. ADDED NOTE 05-21-2013 VTD DESIGNED VTD CHECKED JH DATE 04-15-2013 JOB NUMBER 813318 SHEET . TITLE ROOF PLAN SHEET NU BER M20 3 -OF -3