Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Permit M13-090 - UNIVERSAL FREIGHT - ALTERATION
UNIVERSAL FREIGHT 18290 ANDOVER PK W M13-090 City oi•I'ukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: Address: 3523049018 18290 ANDOVER PK W TUKW Project Name: UNIVERSAL FREIGHT Permit Number: Issue Date: Permit Expires On: M13-090 06/27/2013 12/24/2013 Owner: Name: Address: Contact Person: Name: Address: Email: SEGALE PROPERTIES LLC PO BOX 88028 , TUKVVILA WA 98138 CHUCK STEPHENS 4102 B PL NW , AUBURN WA 98001 CHUCKS @UNIVERSALREFRI G .COM Contractor: Name: UNIVERSAL REFRIGERATION INC Address: PO BOX 614 , AUBURN WA 98071-0614 Contractor License No: UNIVERI159RF Phone: 253 939-5501 Phone: 253 939-5501 Expiration Date: 04/01/2014 DESCRIPTION OF WORK: INSTALL (2) OWNER -OWNED AND SUPPLIED EVAPORATOR COILS AND ISNTALL (2) OWNER -OWNED AND SUPPLIED CONDENSING UNITS. INSTALL THE REFRIGERATION PIPING. Value of Mechanical: $5,930.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $257.06 International Mechanical Code Edition: 2009 DatL 'L I hereby certify that I have read and examined thiPermit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: 4- 4- 7-13_ This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. •A45 loll D.7..1sd• !1R 9Z7MZ PERMIT CONDITIONS Permit No. M13-090 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: Manufacturers installation instructions shall be available on the job site at the time of inspection. 8: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-090 Printed: 06-27-2013 Ilti CITY OF TUKW Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov • Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: x(41'3 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION p / o (King Co Assessor's Tax No.: ,."--47.[:)€•(- 9t/8 Site Address: /601'0 KAY— TGt�! Kms%' N Suite Number: Floor: Tenant Name: apt / r ( New Tenant: 0 Yes p�No PRORERT*.AMO: Name: (moi rri-le301-Z-8;-5 .LL G I( Address: x City: /e.dov i State: k/4 Zip:v6 CONTACT PERSON — Person receiuing.all project communication Name: Shane Heath Bry Chuck Address: 4102 B P1 NW Address: 4102 B P1 NW Phone: (253) 939-5501 Fax: (253) 735-3432 City: Auburn . State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Email:4g ks @universalrefrig.com MECHANICAL. CONNTRACIOR INFORMATION_,; Company Name: Universal Refrigeration Address: 4102 B P1 NW City: Auburn State: WA Zip: 98001 Phone: (253) 939-5501 Fax: (253) 735-3432 Contr Reg No.: UNWERI 159RF Exp Date: 04/01/2014 Tukwila Business License No.: C4S—Octg5 fZ4,/ Valuation of project (contractor's bid price): $ `j ! ` Describe the scope of work in detail: JXs.kce //- fe ,hs*l/ CZ) Owe*Cr owalee aN,444fitto eva oormfor• cerci/Sj ine/ocw7k m, -'c /' i "( r2) owrte t•- o.ybeeea Sct n;" e y,;1 tMMg 4osideea0.7 g4 ‘i e fS• AfPlie/ Wee_ refry -474;i,- 10 yo 7 Use: Residential: New 0 Replacement 0 Commercial: New ❑ Replacement Fuel Type: Electric Er Gas ❑ Other: H: Applicatioiss\Porms-Applications On Line \2011 Applications\iechanical Permit Application Revised 8-9.11.doac Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 2- Floor furnace Z Suspended/wall/floor mounted heater Appliance vent Repair or addition to heatlrefrig/cooling system Air handling unit <10,000 pfin - Unit Type Qty Air handling unit >10,000 cfin 2- Evaporator cooler Z Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 2- 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant: This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180.days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to -exceed 90 days each. The extension shall be reque'sted'in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING ! O' TH j t A E TL Signature: Date:/�/ 20/S Print N. V` 1 P''''�' Day Telephone: 253 9 9-550`1 Mailing Address: 4102 B P1 NW Auburn WA 98001 City State Zip • • H:Wpplications\Fotms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: hap: //www.Tukwila WA .gov Parcel No.: 3523049018 Address: 18290 ANDOVER PK W TUKW Suite No: Applicant: UNIVERSAL FREIGHT RECEIPT Permit Number: M13-090 Status: PENDING Applied Date: 05/16/2013 Issue Date: Receipt No.: R13-01646 Payment Amount: $257.06 Initials: JEM Payment Date: 05/16/2013 12:52 PM User ID: 1165 Balance: $0.00 Payee: UNIVERSAL REFRIGERATION TRANSACTION LIST: Type Method Descriptio Amount Payment Check 46750 257.06 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 205.65 000.345.830 51.41 Total: $257.06 Dei .,+n'I. AC_ 4 R_•)A1'i INSPECTION NO. INSPECTION RECORD Retain a copy with permit M(" -4I0 PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 2" (206) 431-3670 Permit Inspection Request Line (206) 431-2451 VT -- t --- k A, Jeri 4 FA��6, �--- Type of Inspection: � 4k _V Address: �+ lDate -1 O Ak DOLI CI w C Il l / _-�( / Special Instructions: Date Wanted: Wi: `-7 _ y-13 p.m. Requester: Phone Co- S i 0 - 14 -U Approved per applicable codes. Corrections required prior to approval. COMMENTS: Pe/AA,`�--o Date _ .-- �� Insp clot: I REINSPECTION FEE R QUIRED. Prio next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 1 O. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit m -040 INSPECTION NO. PERMIT NO.c CITY OF TUKWILA BUILDING DIVISION -17 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project: ,., CIA .'dcyjkf f`-e.,ii Typ of Inspection: l ()(0t4--jrA ScA' Address: 1 ` r 1 gZ50 Axiooti(J` W Date Called: r Special Instructions: Date Wanted a.m. - ' AJf, .p To •_-1-_, 41;05(4_ o k ext e Requester: P --ii ,tJ .r f '.,A Phone No: -5(0— Qr f' Approved per applicable codes. t�J Corrections required prior to approval. COMMENTS: 4 r (6 4 IZ-3 U4- /-., ` �'" Sc.z. e 6. "- -':,:' .. c1-: 1 60-- ...�..,-J Pr 0 JAL.,-- - ' AJf, .p To •_-1-_, 41;05(4_ o k ext e r P --ii ,tJ .r f '.,A / I Ins ector: Date: �--13 n REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit IN 'ECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 . (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:Type i AI. Jef5 q fr�', e4 -kr of Inspection: 1K e z -u-A- A - Th Aly , Address:,,Date i --2i 0 MovuU iii Called: Special Instructions: / Date Wanted: - 2. -% a:m. p.m. Requester: Phone "i,..\06. - .CCS , /433 Approved per applicable codes. Corrections required prior to approval. COMMENTS: 1' Inspector: (6(1 Date: REINSPECTION FEE REQUIRE. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. FILE COPY GU -192 LK-HTSTB November 2012 Replaces LK-HTSTB, Mar. 2011 Air -Cooled Condensing Unit Technical Guide 1/2-6 HP Indoor and Outdoor Models REVIEWED FOR ODE COMPLIANCE APPROVED JUN 2 5 2013 City of Tukwila BUILDING DIVISION FIECENED 4'tTv nc TIXWILA MAY 16 2013 PERMIT CENTER Nomenclature 2 Features & Benefits 3 Options 4 Hermetic Compressors 5-10 Performance Data 5-8 High Temp., R -404A/507 5 Extended Temp., R -404A/507 6 Low Temp., R -404A/507 7 Medium & High Temp., R-22 8 Unit Specification Data 9 Electrical Data 9-10 Scroll Compressors 11-15 Performance Data 11-14 Medium Temp., R -404A/507 11 Low Temp., R -404A/507 12 Medium Temp., R-22 13 Low Temp., R-22 14 Unit Specification Data 15 Electrical Data 15 Semi—hermetic Compressors 16-21 Performance Data 14 Medium Temp., R -404A/507 16 Low Temp., R -404A/507 17 Medium & High Temp., R-22 18 Unit Specification Data 19 Electrical Data 20-21 Medium & High Temp. 20 Low Temp. 21 Replacement Parts by InterLink"" 21 Di rnen5ional ;Dravgingl Of/Cabinet 22-23 J =::)VAi..AMO3 �. _. . rtr Nomenclature L H Model Compressor L= Larkin H = Hermetic S = Semi-herm. Z = Scroll T Application T= Outdoor N = Indoor S = Beacon Ilan Microprocessor 030 Equiv. HP 1 Temp. Refrigerant C Voltage US MEA Accepted Identifier 005 = 1/2 HP 008/009 = 3/4 HP 010,011=1 HP 01* = 1-1/2 HP 02*=2 HP 03*=3 HP 04»=4HP 05*=5 HP 060 = 6 HP H = High L = Low M = Medium E = Extra Low X = Extended Medium 2 = R-22 6 = R -404A/507 0 2011, Heatcraft Refrigeration Products LLC B= 208/230/1/60 C = 208/230/3/60 D = 460/3/60 F = Stock SCROLL COMPRESSORS Performance Data - Medium Temperature (R -404A/5 • R -404A/507 Model LZ*020M6 Compressor ZS15K4E Capacity BTUH @ 90°F Ambient Suction Temperature 40°F 24,810 35°F 1 30°F 1 25°F 1 20°F 1 10°F 0°F -5°F 25°F 20°F 10°F 0°F 22,630 21,160 19,690 18,210 15,340 12,640 11,390 LZ*025M6 ZS19K4E 29,280 26,730 25,070 23,390 21,700 18,380 15,230 13,750 LZ*030M6 ZS21K4E 35,760 32,760 30,580 28,360 26,170 21,900 17,950 16,140 LZ*035M6 ZS26K4E 43,200 39,310 36,730 34,130 31,560 26,540 21,850 19,690 LZ*045M6 ZS30K4E 48,460 46,490 43,050 39,760 36,560 30,480 24,890 22,310 LZ*055M6 ZS38K4E 57,230 53,990 50,410 46,970 43,530 36,770 30,380 27,400 LZ*060M6 ZS45K4E 65,560 61,960 _ 58,120 54,430 50,680 43,160 35,890 32,490 48,730 41,500 34,510 R -404A/507 Mode) LZ*020M6 Compressor ZS15K4E Capacity BTUH 40°F 35°F 30°F R -404A/507 Model Com ressor p 22,870 Capacity BTUH @ 95°F Ambient Suction Temperature 40°F 35°F 30°F 25°F 20°F 10°F 0°F -5°F LZ*020M6 ZS15K4E 23,850 21,760 20,350 18,930 17,510 14,750 12,150 10,950 LZ*025M6 ZS19K4E 28,110 25,700 24,110 22,490 20,870 17,670 14,640 11,790 LZ*030M6 ZS21K4E 34,460 31,500 29,400 27,270 25,160 21,060 17,260 15,520 LZ*035M6 ZS26K4E 41,600 37,800 35,320 32,820 30,350 25,520 21,010 18,930 LZ*045M6 ZS30K4E 46,740 44,700 41,390 38,230 35,150 29,310 23,930 21,450 LZ*055M6 ZS38K4E 54,940 51,910 48,470 45,160 41,860 35,360 29,210 26,350 LZ*060M6 Z545K4E 62910 59,580 _ 55,880 52,340 48,730 41,500 34,510 31,240 R -404A/507 Mode) LZ*020M6 Compressor ZS15K4E Capacity BTUH 40°F 35°F 30°F @ 100°F Ambient 25°F Suction Temperature 20°F 10°F 0°F -5°F 22,870 20,890 19,540 18,170 16,810 14,160 11,660 10,510 LZ*025M6 ZS19K4E 26,950 24,670 23,150 21,590 20,040 16,960 14,050 12,690 LZ*030M6 ZS21K4E 33,150 30,240 28,220 26,180 24,150 20,220 16,570 14,900 LZ*035M6 ZS26K4E 39,990 36,290 33,910 31,510 29,140 24,500 20,170 18,170 LZ*045M6 ZS30K4E 44,990 42,910 39,730 36,700 33,740 28,140 22,970 20,590 LZ*055M6 ZS38K4E 52,630 49,830 46,530 43,350 40,190 33,950 28,040 25,300 LZ*060M6 Z545K4E 60,260 57,200 53,640 50,250 _ 46,780 39,840 33,130 29,990 . Model LZ*020M6 Compressor ZS15K4E apacity 40°F 35°F BTUH @ 110°F Ambient Suction Temperature 30°F 25°F 20°F 10°F 0°F -5°F 20,920 19,150 17,910 16,660 15,410 12,980 10,690 9,640 LZ*025M6 ZS19K4E 24,600 22,620 21,220 19,760 18,370 15,550 14,190 11,630 LZ*030M6 ZS21K4E 30,500 27,720 25,870 24,000 22,140 18,530 15,190 13,660 LZ*035M6 ZS26K4E 36,690 33,260 31,080 28,880 26,710 22,460 18,490 16,660 LZ*045M6 ZS30K4E 41,430 39,340 36,420 33,640 30,930 25,790 21,060 18,880 LZ*055M6 ZS38K4E 47,970 45,680 42,650 39,740 36,840 31,120 25,700 23,190 LZ*060M6 ZS45K4E - - 49,170 46,060 42,880 36,520 30,370 27,490 * = T for Outdoor, N for Indoor, 5 for Beacon 11 11 SCROLL COMPRESSORS Unit Specifications se Model LZ*020M6 Fig. ++ C Compressor ZS15K4E Connections (ID) Receiver 90% Fall Lbs. 14 Fan(s) 2 Dimensions D (In.) W (In.) H (In.) Net Wt. Lbs. 209 Sound Data dBAt Liquid 1/2 Suction 7/8 28-1/4 37-3/4 19-3/4 LZ*025M6 C ZS19K4E 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 218 71 LZ*030M6 D ZS21K4E 1/2 7/8 20 1 30-1/4 42-1/2 29-3/4 287 73 LZ*035M6 D ZS26K4E 1/2 7/8 20 1 30-1/4 42-1/2 29-3/4 290 72 LZ*045M6 D ZS30K4E 1/2 1-1/8 20 1 30-1/4 42-1/2 29-3/4 317 74 LZ*055M6 D Z538K4E 1/2 1-1/8 20 1 30-1/4 42-1/2 29-3/4 317 73 LZ*060M6 D ZS45K43 1/2 1-1/8 20 1 30-1/4 42-1/2 29-3/4 317 74 LZ*020L6 C ZFO6K4E 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 209 76 LZ*025L6 C ZFO8K4E 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 218 71 LZ*030L6 C ZFO9K4E 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 218 73 71 LZ*035L6 C ZF11K4E 1/2 7/8 14 2 28-1/4 37-3/4 19-3/4 217 1 LZ*045 L6 D ZF13K4E 1/2 1-1/8 20 1 30-1/4 42-1/2 29-3/4 307 73 73 LZ*055L6 D ZF15K4E 1/2 1-1/8 20 1 30-1/4 42-1/2 29-3/4 313 74 LZ*060L6 D ZF18K4E 1/2 1-1/8 20 _ 1 30-1/442-1/2 1/3 29-3/4 317 38 *= T for Ontrinnr Al or inline, c fnr Ron..,,. enM - 45 76 ++ = See Dimensional Drawings for details. 7= Estimated sound pressure values are 10 feet frorn the unit. For estimat ng sound pressure from the unit at different distances, deduct the following from the unit values: 20 feet, deduct 6 dBA for 40 feet, deduct 12 dBA for 80 feet, deduct 18 dBA. This data is typical of 'free field' conditions for horizontal air cooled condensing units at the outlet of the discharge air. The actual sound measurement may vary depending on the condensing unit installation. Factors such as reflecting walls, background noise and mounting conditions may have a significant 1, )fluence on this data. SCROLL COMPRESSORS - Electrical Data LZ*020L68 LZ*020L6C ZFO6K4E-PFV LZ*020L6D LZ*025L6B LZ*025L6C LZ*025L6D LZ*030L6B LZ*030L6C ZFO6K4E-TF5 ZFO6K4E-TFD ZFO8K4E-PFV ZFO8K4E-TF5 208-230 208-230 ZFO8K4E-TFD ZFO9K4E-PFV 460 208-230 208-230 ZFO9K4E-TF5 LZ*030L6D LZ*035L6B LZ*035L6C ZFO9K4E-TFD ZF11 K4E-PFV LZ*035L6D LZ'045L6B LZ*045L6C LZ*045L6D LZ*055L6B ZF11K4E TF5 460 208-230 208-230 460 208-230 208-230 1 3 3 1 3 3 1 3 3 1 3 60 60 60 60 60 60 60 60 60 60 60 12.2 8.3 3.8 14.7 8.7 4.5 14.7 9.9 5.1 18.6 12.2 61.0 55.0 27.0 73.0 63.0 31.0 2 2 2 2 2 2 1/15 1/15 1/15 1.0 1.0 1.0 20 38 25 40 12.0 30 15 24 15 25 9.0 19 15 24 15 25 A A 1/15 1/15 1115 1.0 1.0 20 38 30 45 12.0 30 15 29 20 30 11.0 23 1.0 15 24 15 25 A A 88.0 77.0 39.0 109.0 88.0 2 2 2 2 2 1/15 1/15 1/15 1.0 20 38 30 45 12.0 30 1.0 15 24 20 25 6.0 19 1.0 15 15 15 15 A A ZF11K4E-TFD ZF13K4E-PFV ZF13K4E TF5 ZF13K4E TFD ZF15K4E-PFV 460 208-230 208-230 LZ*055L6C LZ*055L6D LZ*060L6C LZ*060L6D ZF15K4E-TF5 ZF15K4E-TFD ZF18K4E TF5 460 208-230 208-230 ZF18K4E-TFD 460 208-230 460 3 1 3 3 1 3 3 3 3 60 60 60 60 60 60 60 60 60 6.4 24.0 13.5 7.4 28.8 19.2 8.7 21.5 8.3 44.0 129.0 99.0 49.5 169.0 123,0 62.0 156.0 70.0 2 1 1 1 1 1 1 1 1 1/15 _1/15 1/15 1.0 1.0 1.0 24 38 40 50 12.0 30 20 15 29 25 30 6.0 23 15 15 15 A A 1/3 1/3 1/3 1/3 3.5 34 45 50 60 11.0 30 3.5 1.9 3.5 20 15 40 38 24 30 40 11.0 30 15 25 9.0 19 50 50 60 10.0 30 1/3 1/3 1/3 1/3 3.5 1.9 28 15 40 45 50 10.0 30 24 20 25 8.0 19 3.5 30 44 50 60 12.0 35 1.9 15 29 20 30 11.0 23 * = T for Outdoor, N for Indoor, S for Beacon I Per UL and NEC, RLA values have been calculated by dividing the Maximum Continuous Current (MCC) by 1.56. Power supplied by custorner. 'Consult factory for 50 HZ applications. 15 Model Number LZ*020M6B Part Number ZS15K4E-PFV Power Supply Compressor Fan Motor MCA ''' MOPD Evap. Fan A1205 Defrost Heater Am ps Volts 208-230 Ph 1 Hzt 60 RLA 14.1 IRA 68.0 Qty. 2 HP 1 FLA 1/15 1.0 Air 1 Elec. Air 30 Elec. 20 38 40 LZ*020M6C ZS15K4E-TF5 , 208-230 3 60 9.6 58.0 2 1/15 1.0 15 24 20 30 9.0 LZ*020M60 Z515K4E-TFD 460 3 60 4.8 29.0 2 1/15 1.0 15 24 15 25 A 19 A LZ*025M6B ZS19K4E-PFV 208-230 1 60 16.2 , 75.0 2 1/15 1.0 21 38 35 45 12.0 LZ*025M6C ZS19K4E-TF5 208-230 3 60 12.3 73.0 2 1/15 1.0 20 29 25 35 11.0 30 23 LZ*025M6D ZS19K4E-TFD 460 3 60 5.8 38.0 2 1/15 1.0 15 24 15 25 A A LZ*030M68 Z521K4E-PFV 208-230 1 60 20.8 112.0 1 1/3 3.5 30 42 50 60 12.0 LZ*030M6C ZS21 K4E TF5 208-230 3 60 13.7 93.0 1 1/3 3.5 21 38 30 45 12.0 30 30 LZ*030M6D ZS21K4E-TFD 460 3 60 6.2 48.0 1 1/3 1.9 15 24 15 25 A A LZ*035M6B Z526K4E-PFV 208-230 1 60 21.2 1 104.0 1 1/3 3.5 30 42 45 60 12.0 30 LZ*035M6C ZS26K4E-TF5 208-230 3 60 13.9 93.0 1 1/3 3.5 21 38 30 45 12.0 30 LZ*035M6D ZS26K4E-TFD 460 3 60 6.2 48.0 1 1/3 1.9 15 24 15 25 A A LZ*045M6B ZS30K4E-PFV 208-230 1 60 23.4 137.0 1 1/3 3.5 33 59 50 60 11.0 47 LZ*045M6C ZS30K4E TF5 208-230 3 60 1 18.4 114.0 1 1/3 3.5 27 44 40 50 12.0 35 LZ*045M60 ZS30K4E TFD 460 3 60 8.4 58.0 1 1/3 1.9 15 29 20 35 11.0 23 • LZ*055M6B ZS38K4E-PFV 208-230 1 60 28.8 169.0 1 1/3 3.5 40 59 50 60 12.0 47 LZ*055M6C ZS38K4E-TF5 208-230 3 60 19.2 123.0 1 1/3 3.5 28 44 45 50 12.0 35 LZ*055M6D ZS38K4E-TFD 460 3 60 8.7 62.0 1 1/3 1.9 15 29 20 30 10.0 23 LZ*060M6C ZS45K4E-TF5 208-230 3 60 21.5 156.0 1 1/3 3.5 30' 44 50 60 12.0 35 LZ*060M6D ZS45K4E TFD 460 3 60 83 70.0 1 1/3 1.9 _ 15 29 20 30 10.6 23 LZ*020L68 LZ*020L6C ZFO6K4E-PFV LZ*020L6D LZ*025L6B LZ*025L6C LZ*025L6D LZ*030L6B LZ*030L6C ZFO6K4E-TF5 ZFO6K4E-TFD ZFO8K4E-PFV ZFO8K4E-TF5 208-230 208-230 ZFO8K4E-TFD ZFO9K4E-PFV 460 208-230 208-230 ZFO9K4E-TF5 LZ*030L6D LZ*035L6B LZ*035L6C ZFO9K4E-TFD ZF11 K4E-PFV LZ*035L6D LZ'045L6B LZ*045L6C LZ*045L6D LZ*055L6B ZF11K4E TF5 460 208-230 208-230 460 208-230 208-230 1 3 3 1 3 3 1 3 3 1 3 60 60 60 60 60 60 60 60 60 60 60 12.2 8.3 3.8 14.7 8.7 4.5 14.7 9.9 5.1 18.6 12.2 61.0 55.0 27.0 73.0 63.0 31.0 2 2 2 2 2 2 1/15 1/15 1/15 1.0 1.0 1.0 20 38 25 40 12.0 30 15 24 15 25 9.0 19 15 24 15 25 A A 1/15 1/15 1115 1.0 1.0 20 38 30 45 12.0 30 15 29 20 30 11.0 23 1.0 15 24 15 25 A A 88.0 77.0 39.0 109.0 88.0 2 2 2 2 2 1/15 1/15 1/15 1.0 20 38 30 45 12.0 30 1.0 15 24 20 25 6.0 19 1.0 15 15 15 15 A A ZF11K4E-TFD ZF13K4E-PFV ZF13K4E TF5 ZF13K4E TFD ZF15K4E-PFV 460 208-230 208-230 LZ*055L6C LZ*055L6D LZ*060L6C LZ*060L6D ZF15K4E-TF5 ZF15K4E-TFD ZF18K4E TF5 460 208-230 208-230 ZF18K4E-TFD 460 208-230 460 3 1 3 3 1 3 3 3 3 60 60 60 60 60 60 60 60 60 6.4 24.0 13.5 7.4 28.8 19.2 8.7 21.5 8.3 44.0 129.0 99.0 49.5 169.0 123,0 62.0 156.0 70.0 2 1 1 1 1 1 1 1 1 1/15 _1/15 1/15 1.0 1.0 1.0 24 38 40 50 12.0 30 20 15 29 25 30 6.0 23 15 15 15 A A 1/3 1/3 1/3 1/3 3.5 34 45 50 60 11.0 30 3.5 1.9 3.5 20 15 40 38 24 30 40 11.0 30 15 25 9.0 19 50 50 60 10.0 30 1/3 1/3 1/3 1/3 3.5 1.9 28 15 40 45 50 10.0 30 24 20 25 8.0 19 3.5 30 44 50 60 12.0 35 1.9 15 29 20 30 11.0 23 * = T for Outdoor, N for Indoor, S for Beacon I Per UL and NEC, RLA values have been calculated by dividing the Maximum Continuous Current (MCC) by 1.56. Power supplied by custorner. 'Consult factory for 50 HZ applications. 15 --*G-/ .80Z. LK-MPTB May 2008 Replaces LK-MPTB, May 2007 Medium Profile Unit Coolers Technical Guide Models MMT6 - Air Defrost MLT6/4 - Electric Defrost MLG6/4 - Hot Gas Defrost www.Iarkinproducts.com Table of Contents Nomenclature Features & Benefits Performance Data & Specifications Air Defrost 4-5 Electric Defrost 6-7 Hot Gas Defrost 8-9 Physical Data 10-11 Dimensional Data 12 Replacement Parts by InterLine 13 Standard Nozzle Selection 14 2 3 Energy Solutions us We have made a commitment to customer needs, innovation and environmental stewardship and have dedicated ourselves to delivering energy-efficient choices. PSC and EC motors will reduce costs, improve the bottom line and enhance equipment performance and service life. Choose the most energy-efficient motor available for evaporators. The EC motor is an Energy Solutions® option on new Larkin Medium Profile evaporators. Available on all new equipment or as an easy -to - install, drop-in replacement aftermarket part from InterLinkTM' Commercial Refrigeration Parts. Because they're a drop-in replacement for existing PSC motors, installation is quick and easy. It's a high impact, quick payback solution for reducing costs and achieving green initiatives without replacing the entire system. EC motors by InterLink are up to 75% efficient - that's a 30-35% increase over permanent -split capacitor (PSC) motors. With all of this added efficiency, you can count on more energy savings and lower operational costs while taking a step in the right direction toward conserving our planet's resources. To learn more about EC motors, visit www.interlinkparts.com/ec. Nomenclature M Model Series MT6 Model Type 130 Capacity B Electrical Code A Design Revision Larkin Medium MT6 = Air defrost, 6 FPI # BTUH x 100 A = 115/1/60 Profile Unit Coolers LT6 = Electric defrost, 6 FPI B = 208-230/1/60 LT4 = Electric defrost, 4 FPI C = 208-230/3/60 LG6= Hot gas defrost, 6 FPI D = 460/3/60 LG4 = Hot gas defrost, 4 FPI M = 460/1/60 E = 575/3/60 L = 575/1/60 N = 110/1/50 Q = 220/1/50 R = 380/1/50 V = 380/3/50 AE = 115/1/60 (EC) BE = 208-230/1/60 (EC) CE = 208-230/3/60 (EC) 2 02008 Heatcraft Refrigeration Products LLC Performance Data Model MLT6/MLT4 Model MLT6101 Capacity 10°F TD -20°F SST BTUH Electric 6°CTD -29°C SST Watts Defrost 60 Hz Fan Data Diameter No. CFM m'h in. mm AirThrow*t Diffused Extended (Std.) (Opt.) ft. in ft. m 10,100 2,960 1 2,350 4,000 18 457 50 15 65 20 MLT6140 14,000 4,100 1 2,250 3,830 18 457 50 15 65 20 MLT6190 19,000 5,570 2 4,700 7,990 18 457 50 15 65 20 13.5 MLT6260 26,000 7,620 2 4,500 7,650 18 457 50 15 65 20 60 MLT6310 31,000 9,080 3 7,050 11,990 18 457 50 15 65 20 MLT6390 39,000 11,420 3 6,750 11,480 18 457 50 15 65 20 MLT6430 43,000 12,590 4 8,800 14,960 18 457 50 15 65 20 MLT6520 52,000 15,230 4 8,400 14,280 18 457 50 15 65 20 MLT6620 62,000 18,160 5 10,000 17,000 18 457 50 15 65 20 60 MLT4100 10,000 2,930 1 2,325 3,950 18 457 50 15 65 20 MLT4165 16,500 4,830 2 4,900 8,330 18 457 50 15 65 20 MLT4220 22,000 6,440 2 4,650 7,910 18 457 50 15 65 20 60 MLT4250 25,000 7,320 3 7,350 12,500 18 457 50 15 65 20 MLT4330 33,000 9,670 3 6,975 11,860 18 457 50 15 65 20 v; MLT4370 37,000 10,840 4 9,100 15,470 18 457 50 15 65 20 MLT4370 MLT4440 44,000 12,890 4 8,700 14,790 18 457 50 15 65 20 MLT4530 53,000 15,520 5 10,350 17,600 18 457 50 15 65 20 Model MLT6/MLT4 Model MLT6101 Electric Capacity Defrost Fan Data 50 Hz+ Air Throw." 10°FTD -20°F SST 6°CTD -29°C SST No. CFM m'h DiameterDiffused Temperature °F (Std.) Extended (Opt.) BTUH Watts in. rnm ft. m ft. m 8,832 2,590 1 2,115 3,600 18 457 45 13.5 60 185 MLT6140 12,236 3580 1 2,025 3,440 18 457 45 13.5 60 18.5 MLT6190 16,652 4,880 2 4,230 7,190 18 457 45 13.5 60 18.5 MLT6260 22,724 6,660 2 4,050 6,890 18 457 45 13.5 60 18.5 MLT6310 27,140 7,950 3 6,345 10,790 18 457 45 13.5 60 18.5 MLT6390 34,132 10,000 3 6,075 10,330 18 457 45 133 60 18.5 MLT6430 37,628 11,020 4 7,920 13,460 18 457 45 13.5 60 18.5 MLT6520 45,448 13,310 4 7,560 12,850 18 457 45 13.5 60 18.5 MLT6620 54,188 15,870 5 9,000 15,300 18 457 45 13.5 60 18.5 2 k a. i? v MLT4100 8,740 2,560 1 2,093 3,560 18 457 45 13.5 60 18.5 MLT4165 14,444 4,230 2 4,410 7,500 18 457 45 13.5 60 18.5 MLT4220 19,228 5,630 2 4,185 7,120 18 457 45 13.5 60 18.5 MLT4250 21,896 6,410 3 6,615 11,250 18 457 45 13.5 60 18.5 MLT4330 28,888 8,460 3 6,278 10,670 18 457 45 13.5 60 18.5 MLT4370 32,384 9,490 4 8,190 13,920 18 457 45 13.5 60 18.5 MLT4440 38,456 11,260 4 7,830 13,310 18 457 45 133 60 18.5 MLT4530 46,368 13,580 5 9,315 15,840 18 457 45 13.5 60 18.5 "Optional molded fan guards allow for extended air throw; standard wire guards promote air diffusion 'Air throw data based on 12 -ft. high ceilings with no obstructions where velocity drops to 50 FPM * For EC motors, use 60 Hz capacity and airflow values (Units with EC motors operating at 50 Hz will not see a reduction in performance due to the electronic control of the motor) 6 Capacity Correction Factors For Electric and Hot Gas Defrost Units Saturated Suction +20 -10 -20 -30 -40 Temperature °F Saturated Suction -7 -23 -29 -34 -40 Temperature °C Multiply Capacity By 1.15 1.02 1.00 0.90 0.80 Specifications Model MLT6/MLT4 Electric Defrost 60 Hz Model PSC Motor 208- 230/1/60 Amp 460/1/60 Am.s 575/1/60 Am's Watts EC Motor 208- 230/1/60_ Am's a Watts 208- 230/1/60 Defrost Heater 208- 230/3/60 460/1/60 460/3/60 575/3/60 :G; '`.N MLT6101 1/4 1.8 275 1.0 275 0.7 310 1.4 275 2,730 11.9 8.2 5.9 4.1 3.3 MLT6140 1/4 1.8 275 1,0 275 0.7 310 1.4 275 2,730 11.9 82 5.9 4.1 3.3 MLT6190 1/4 3.6 550 2.0 550 1.4 620 2.8 550 5,350 23.3 16,0 11.6 8.3 6.6 MLT6260 1/4 3.6 550 2.0 550 1.4 620 2.8 550 5,350 23.3 16.0 11.6 8.3 6.6 MLT6310 1/4 5.4 825 3.0 825 2.1 930 4.2 825 7,750 33.7 23.2 16.8 12.0 9.6 MLT6390 1/4 5.4 825 3.0 825 2.1 930 4.2 825 7,750 33.7 23.2 16.8 12.0 9.6 0 MLT6430 1/4 7.2 1,100 4.0 1,100 2.8 1,240 5.6 1,100 10,200 - 30.5 22.2 15.8 12.6 MLT6520 1/4 7.2 1,100 4.0 1,100 2.8 1,240 5.6 1,100 10200 - 30.5 22.2 15.8 12.6 MLT6620 1/4 9.0 1,375 5.0 1,375 3.5 1,550 7.0 1,375 11,600 - 34.7 25.2 18.1 14.4 13.1 MLT4100 1/4 1:8 275 1.0 275 0.7 310 1.4 275 2,730 11.9 82 5.9 4.1 33 MLT4165 1/4 3.6 550 2.0 550 1.4 620 2.8 550 5,350 23.3 16.0 11.6 8.3 6.6 MLT4220 1/4 3.6 550 2.0 550 1.4 620 2.8 550 5,350 23.3 16.0 11.6 8.3 6.6 `y' a MLT4250 1/4 5.4 825 3.0 825 2.1 930 4.2 825 7,750 33.7 23.2 16.8 12.0 9.6 MLT4330 1/4 5.4 825 3.0 825 2.1 930 4.2 825 7,750 33.7 23.2 16.8 12.0 9.6 ir et MLT4370 1/4 7.2 1,100 4.0 1,100 2.8 1,240 5.6 1,100 10,200 - 30.5 22.2 15.8 12.6 MLT4440 1/4 7.2 1,100 4.0 1,100 2.8 1240 5.6 1,100 10,200 - 30.5 22.2 15.8 12.6 MLT4530 1/4 9.0 1,375 5.0 1,375 3.5 1,550 7.0 1,375 11,600 - 34.7 25.2 18.1 14.4 Model MLT6/MLT4 Model MLT6101 HP 1/4 Electric PSC Motor 220/1/50 Amps 1.8 Defrost 380/1/50 Amps 50 EC Motor 220/1/50 Hz Watts Defrost Heater 220/1/50 380/3/50 Amps Amps Total 1.0 1.4 2,510 11.4 3.4 MLT6140 1/4 1.8 1.0 1.4 2,510 11.4 3.4 MLT6190 1/4 3.6 2.0 2.8 4,910 22.3 6.9 MLT6260 1/4 3.6 2.0 2.8 4,910 213 6.9 MLT6310 1/4 5.4 3.0 4.2 7,090 32.2 9.9 MLT6390 1/4 5.4 3.0 4.2 7,090 32.2 9.9 MLT6430 1/4 7.2 4.0 5.6 9,340 - 13.1 MLT6520 1/4 7.2 4.0 5.6 9,340 - 13.1 MLT6620 1/4 9.0 5.0 7.0 10,620 - 15.0 nch MLT4100 1/4 1.8 1.0 1.4 2,510 11.4 3.4 MLT4165 1/4 3.6 2.0 2.8 4,910 22.3 6.9 MLT4220 1/4 3.6 2.0 2.8 4,910 22.3 6.9 t IS. C I& V' MLT4250 1/4 5.4 3.0 4.2 7,090 32.2 9.9 MLT4330 1/4 5.4 3.0 4.2 7,090 32.2 9.9 MLT4370 1/4 7.2 4.0 5.6 9,340 - 13.1 MLT4440 1/4 7.2 4.0 5.6 9,340 - 13.1 MLT4530 1/4 9.0 5.0 7.0 10,620 - 15.0 * 575/1/60 motors are 1/3 HP 7 Physical Data Model MMT6 Model MMT6130 Air No. of Fans 1 Defrost Connections (in.) Defrost Connections Suction ODF 7/8 Approx. Net Weight Coil Inlet ODF 1/2 Suction ODF 7/8 External Equalizer ODF 1/4 Drain FPT 3/4 lbs. kg 115 52 MMT6155 1 1/2 1-1/8 1/4 3/4 123 56 MMT6245 2 7/8 1-1/8 1/4 3/4 134 61 MMT6300 2 7/8 1-1/8 1/4 3/4 148 67 MMT6365 3 7/8 1-3/8 1/4 3/4 200 91 MMT6450 3 1-1/8* 1-3/8 1/4 3/4 227 103 MMT6510 4 1-1/8* 1-5/8 1/4 3/4 230 104 MMT6600 4 1-1/8* 1-5/8 1/4 3/4 255 116 MMT6710 5 1-1/8* 1-5/8 1/4 3/4 285 129 * Supplied with adapter to 7/8 ODF Model MLT6/MLT4 Model MLT6101 No. of Fans 1 Electric Coil Inlet ODF 1/2 Defrost Connections Suction ODF 7/8 (in.) External Equalizer ODF 1/4 Drain FPT 3/4 Approx. Net Weight lbs. kg 118 54 M LT6140 1 1/2 7/8 1/4 3/4 ' 126 57 MLT6190 2 7/8 1-1/8 1/4 3/4 138 63 MLT6260 2 1-1/8* 1-3/8 1/4 3/4 1;53. 69= MLT6310 3 1-1/8* 1-3/8 1/4 3/4 210 95 ' MLT6390 3 1-1/8* 1-3/8 1/4 3/4 237 108 MLT6430 4 1-1/8* 1-5/8 1/4 3/4 267 121 MLT6520 4 1-1/8* 1-5/8 1/4 3/4 300 136 MLT6620 5 1-1/8* 1-5/8 1/4 3/4 338 153 MLT41'00 1 1/2 7/8 1/4 3/4° 125, 56?,' MLT4165 2 7/8 1-1/8 1/4 3/4 136 62 MLT4220 2 1-1/8* 1-3/8 1/4 3/4 151 68 a c MLT4250 3 1-1/8* 1-3/8 1/4 3/4 207 94 MLT4330 3 1-1/8* 1-3/8 1/4 3/4 234 106 MLT4370 4 1-1/8* 1-5/8 1/4 3/4 262 119 MLT4440 4 1-1/8* 1-5/8 1/4 3/4 ° 295 134 MLT4530 5 1-1/8* 1-5/8 1/4 3/4 332 151 * Supplied with adapter to 7/8 ODF 10 Dimensional Data All Models Dimensions -.113-7/8%- 480 mm 17-1/2° 444 mm 1 24" 608 mm -� Air Flow F c A B 1 23 -1/4" o 590mm 2-1/2" 15-1/24- 64 mm 390 mm 22-3/4"—.- 578 mm Refrigerant Connection End All Models Dimensional Data Elect ical Connection End Model MMT6130 6 FPI Models 4 FM Models Dimensions Defrosts Defrosts A B C D E F Elec. MLT6101 Hot Gas Elec. Hot Gas in. mm in. mm in. mm in. mm in. mm in. mm - - - 39-5/16 1,051 30-1/4 770 - - - - - - 5-7/16 138 MMT6155 MLT6140. - MLT4100 - 39-5/16 1,051 30-1/4 770 - - - - - - 5-7/16.: ..138. MMT6245 MLT6190 MLG6190 MLT4165 MLG4165 67-5/16 1,761 58-1/4 1,480 - - - - - - 5-7/16 138 MMT6300 MLT6260 MLG6260 MLT4220 MLG4220 67-5/16 1,761 58-1/4 1,480 - - - - - - 5-7/16'. 138 MMT6365 MLT6310 MLG6310 MLT4250 MLG4250 95-5/16 2,471 86-1/4 2,190 - - - - - - 5-7/16 138 MMT6450 MLT 6390 MLG6390 MLT4330 MLG4330 95-5/16 2,471 86-1/4 2,190 - - - - - - 5-7/16 138 MMT6510 MLT6430 MLG6430 MLT4370 MLG4370 123-5/16 3,181 114-1/4 2,900 56 1,420 58-1/4 1,480 - - 5-7/16 138 MMT6600 MLT6520 ML?G6520 MLT4440 MLG4440 1234/16 3,181 114-1/4 .2,900 56 1,420 58-1/4 1,480 - - 5-7/16 138 MMT6710 MLT6620 - MLT4530 - 136-13/16 3,530 129-3/4 3,300 51 1,300 53-1/4 1,350 25-1/2 650 4-15/16 125 NOTES: Evaporator mounting brackets accept up to 1/2" hanger rod Shown with optional molded fan guard 12 May 24, 2013 Chuck Stephens 4102 B Place NW Auburn, WA 98001 • City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director RE: Correction Letter #1 Mechanical Permit Application Number M13-090 Universal Freight —18290 Andover Pk W Dear Mr. Stephens, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Allen Johannessen at 206 433-7163 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, File N N. MI3-090 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Tukwila Building Division Alien Johannessen, Plan Examiner Building Division Review Memo Date: May 23, 2013 Project Name: Universal Freight Permit #: M13-090 Plan Review: Allen Johannessen, Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36; all sheets shall be the same size. New revised plan sheets shall be the same size sheets as those previously submitted.) (If applicable) Structural Drawings and structural calculations sheets by a registered engineer shall have a current signed stamp -seal. Architectural design sheets and documents by a registered architect shall also have a current signed stamp -seal. 1. The plan submitted shows the new mechanical units located on the roof, close to the outer edge. Guards shall be provided where appliances, equipment , fans or other components that require service located within 10 feet of a roof edge or open side of a walking surface and such edge or open side is located more than 30 inches above the floor, roof or grade below. The guard shall extend not less than 30 inches beyond each end of such appliances, equipment, and the top of the guard shall be located not less than 42 inches above the elevated surface adjacent to the guard. The guard shall be constructed so as to prevent the passage of a 21 -inch -diameter sphere and shall comply with the loading requirements for guards specified in the International Building Code. Provide a plan view of that portion of the building with dimensions showing the distance from roofs edge to the new equipment. If within 10 feet provide guard specifications or show equipment located at or more than 10 feet from roofs edge. (2009 IMC [B] 304.11) 2. Provide details to show how the equipment is attached to the roof to prevent effects of a seismic event and/or wind and placed on an approved raised platform or sleepers. Provide details for securing roof penetrations, flashing etc. (IMC 301.12 & 301.15) 3. Provide details for condensation pipes and where condensation shall be disbursed. (IMC 307.2) 4. The scope of work indicates relocating equipment. Specify or show on the plan where the units are removed from and if applicable, provide details or specifications for sealing roof penetrations. Should there be questions concerning the above requirements, contact the Building Division at 206-431-3670. No further comments at this time. "ERNT COORS COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-090 PROJECT NAME: UNIVERSAL FREIGHT SITE ADDRESS: 18290 ANDOVER PK W Original Plan Submittal Response to Incomplete Letter # DATE: 06-14-13 X Response to Correction Letter # 1 Revision # After Permit Issued EPARTMENTS: —V5 u`lding ivislon Public Works n Fire Prevention Structural Planning Division ❑ Permit Coordinator 1111 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 06-18-13 Not Applicable ❑ Comments: Permit Center Use Only, INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required n No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 07-16-13 Not Approved (attach comments) n Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 111OPERN61T COORD COP. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-090 DATE: 05/16/13 PROJECT NAME: UNIVERSAL FREIGHT, SITE ADDRESS: 18290 ANDOVER PK W X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # Revision # after Permit Issued DEPARTMENTS: O v,41 B r'i s in Division Public Works ❑ AP\ WA Fire Prevention Structural Planning Division Permit Coordinator El DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete L' Incomplete ❑ DUE DATE: 05/21/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route IS/1 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 06/18/13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) '0 Notation: REVIEWER'S INITIALS: DATE: Permit Center Use, Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 1: Fire 0 Ping 0 PW 0 Staff Initials: • City of Tukwila REVISION SUBMITTAL Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Web site: http;//www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fad etc Date: 5/31/2013 Plan Check/Permit Number: Mi l-n(n ❑ Response to Incomplete Letter # • Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ca Revision requested by a City Building Inspector or Plans Examiner Project Name: Universal Freight Project Address: Contact Person: Chunk Stephens Address is 18290 Andover Park RECEIVED CITY OF TUKWILA 'JUN .14 2e13 PERMIT CENR way tNPct 98188 Phone Number: 253-939-5501 Summary of Revision: 1. The condensing units will be located on top of the existing walk-in cooler box inside the 11 •_n" tall 2. The condensing units. CU -1 & 2. are secured to 4"x 4" skids placed on top of the walk-in box. PIcase-see slew detail submitted with revision/correction package #1. 3. Condensate shallflow to floor drain adjacent to walk-in box. Revised plans will be clouded to show the path of the condensate from CU -1- & 2 across the box roof, sloping down the Iony side of the hack of the walk-in hux •dnd finally •lieiny C racuated intu the existing floor drain. 4. Equipment was previously ground mounted , and [floated on the gide of the huildingnutside. Sheet Number(s): p��q At- i * HP "Cloud" or highlight all "ti Jas of revision including date of revision '' Received at the City of Tukwila Permit Center by: 042=s°L 4) Entered in Permits Plus on 01103 H:1ApplieaionsWmms-Appintioaa On Line \2010 ApplieadoM7-2010 - Revision Submiaal.doc Created: 8-13-2004 Revised: 7-2010 Contractors or Tradespeople Pyrtter Friendly Page • General/Specialty Contractor A business registered as a construction contractor with Lal to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company UNIVERSAL REFRIGERATION INC 2539395501 Po Box 614 Auburn WA 980710614 King Corporation UBI No. Status License No. License Type Effective Date Expiration Date Suspend Date Specialty 1 Specialty 2 600599723 Active UNIVERI159RF Construction Contractor 12/6/1985 4/1/2014 Commercial /Industrial / Refrig Unused Other Associated Licenses License NameType Effective Date Specialty 1 Specialty 2 Effective Date Expiration Date Status UNIVER1000B0 UNIVERSAL REFRIGERATION INC Electrical Contractor Hvac/Rfrg Ltd Energy Unused 1/20/2000 1/20/2014 Active Business Owner Information Name Role Effective Date Expiration Date GATES, CHRISTOPHER A President 03/29/2012 Amount GALVIN, BRYAN S Vice President 03/29/2012 01CG749762-9 RAEDER, STEVEN C President 01/01/1980 03/29/2012 VERNON, GUY E 01/01/1980 01/01/1980 JACKSON, SHELDON G 04/01/2012 01/01/1980 01/01/1980 OSENBAUGH, CHARLES R $1,000,000.0003/20/2012 01/01/1980 01/01/1980 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 5 AMERICAN STATES INS CO EX903622 12/06/2001 Until Cancelled $6,000.00 03/18/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 27 American States Insurance Co 01CG749762-9 04/01/2013 04/01/2014 $1,000,000.0003/18/2013 26 American States Insurance Co 01CG749762-8 04/01/2012 04/01/2013 $1,000,000.0003/20/2012 25 American States Insurance Co 01CG7497627 04/01/2010 04/01/2012 $1,000,000.00 03/07/2011 24 AMERICAN STATES INS CO 01CG7497625 04/01/2009 04/01/2010 $1,000,000.00 03/09/2009 23 AMERICAN STATES INS CO 01CG7497624 04/01/2008 04/01/2009 $1,000,000.00 03/11/2008 22 FIRST NAIL INS CO OF AMERICA 01CG7497623 04/01/2007 04/01/2008 $1,000,000.00 03/01/2007 https://fortress.wa.gov/lni/bbip/Print.aspx 06/27/2013 HVAC LEGEND INLINE EXHAUST FAN(S) ROOFTOP EXHAUST FAN SIDEWALL EXHAUST FAN CEILING EXHAUST FAN X T -BAR SUPPLY. DIFFUSER T -BAR RETURN GRILLE HARDLID SUPPLY DIFFUSER HARDLID RETURN GRILLE FIRE SMOKE DAMPER VOLUME DAMPER SMOKE DETECTOR FLEXIBLE DUCT SA/RA ROUND DUCT UP ROUND DUCT DOWN 10x10 CDS 300 CFM -10"6J INTERIOR WAREHOUSE WALL REVISIONS No changes shall be made to the Scope of %lark without prior approval of '7;110-^Jilb Building Division. will require a new plan submittal 4.. .:wade additional plan review fees. I ttk - AIR CONDITIONING =HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF` AUBURN: . (253) 939-5501 • ., TACOMA: (253)922-3141 SEATTLE: . (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING -2001 z 0 1 -- cc U ..W 0 0 W cc PERMIT ISSUE CO T-. CORRECTION .LE I I ER REVISIONS CO T co N FILCOPY Permit No. ref Plan mview approval is subjeg subjectto atW ions. A; rwl of construction documents not authorize th: . tion of any ;; , . _ •axle or ordname. Receipt of iapproved F'-:;� :By '� 1. RELOCATE AND INSTALL (2) EXISTING EVAPORATOR COILS. .. 2 RELOCATE AND INSTALL (2) EXISTING CONDENSING UNITS. 3 INSTALL REFRIGERATION PIPING. EXTERIOR WAREHOUSE WALL EQUIPMENT LOCATED AND HANGING FROM CEILING OF 2ND COOLER O EQUIPMENT LOCATED AND MOUNTED ON TOP OF 2ND COOLER )OFTOP/INDO OR REFRIGERATION EQUIPMENT SCHEDULE REFRIGERANT CU -1 LARKIN LZTO4M6D W.I. COOLER #2 TYPE R -404A QUANTITY 20 LBS.* MCA MOCP DIMENSIONS (LxWxH) WEIGHT 4.0 460/3/60 29.0 CU -2 EC -1 LARKIN LARKIN LZTO4M6D MLT6310 EC -2. LARKIN MLT6310 .. W.I. COOLER #2 R -404A 20 LBS.* 4.0. 460/3/60 29.0 SEPARATE PERMIT REQUIRED FOR: o lvtiebanteat GioEiectrical plumbing as Piping y of Tukwila 31 '"''NG DIVISION PROJECT START DATE: RECEIVED CITY OF TUKWILA JUN 1 4 2013 r. P RMIT:CENTER DRAF=TER DESIGNER: PROJECT MANAGER: 5/15/13 CFN CS` CS 35 PROFILE UINT COOLERS PROFILE UINT COOLERS .25 460/1/60.• 3.0 16.8 16.8 460/1/60 3.0 30-1/4 x 42-1/2 x 29-3/4 95-5/16 x 15-1/2 x 23-1/4 95-5/16 x 15-1/2 x 23-1/4 317 LBS. 210 LBS. * RECEIVER 90% FULL .' NOTE: These plans are diagrammatical only: Please verify aII dimensions at job site.. END NO CITY APPROVAL l SHEET NUMBER: HVAC NOTES 1. DUCT INSULATION SHALL MEET REQUIREMENTS SECTION 1414.2 OF THE 2009 WSEC AND 2. SMOKE DETECTOR(S) INSTALLED IN MAIN DUCTS PER SECTION 606 OF THE 2009 IMC. DUCT DETECTORS SHALL SHUT DOWN POWER UNIT UPON ACTIVATION AND A "SUPERVISORY" BE INITIATED AT FIRE ALARM PANEL UPON DETECTOR ACTIVATION. IMC SECTION 606.2.1. OF:. TABLE 14-5. RETURN AIR HVAC SMOKE TO THE ZONE SHALL SMOKE DUCT 3. DUCTWORK-MAINTRUNK IS R-4.2 IN CONDITIONED SPACES AND R-8 IN UNCONDITIONED SPACES AS PER THE WSEC.` 4.: ALL SINGLE PACKAGE HVAC UNITS SHALL BE INSTALLED WITH ECONOMIZERS PER MANUFACTURER'S INSTALLATION INSTRUCTIONS PER I.M.C. 2009, SECTION 403, CHAPTER 6, AND SHALL OPERATE, PER W.S E.C: 2009, SECTION 1413... 5., EQUIPMENT INSTALLATION INSTRUCTIONS TO BE ON-SITE FOR INSPECTIONS. 6 ALL HVAC EQPM. TO BE LABELED TO THE SPACE SERVED. 7 DUCTS TO BE SUPPORTED AT EACH DIRECTION CHANGE VERTICAL AT 12'-0" MAX., HORIZONTAL AT 10'-0" MAX. WITH STRAP, OR 8'-0" MAX. F TRAPEZE SUPPORT. 8. THERMOSTAT TO BE SEVEN-DAY TYPE AND HAVE NIGHT SETBACK WITH 5 DEGREE DEADBAND. 9. THE HVAC INSTALLATION SHALL BE COMPLETE WHEN ALL SECTIONS OF 1416 WSEC HAVE BEEN SATISFIED. THIS SHALL INCLUDE AS -BUILT DRAWINGS, SUBMITTALS, 0&M MANUALS, SYSTEM BALANCE REPORT, AND COMM- ISSIONING REPORT, 10: DUCT SEALING SHALL MEET REQUIREMENTS OF WSEC 1414.1.. DUCT WORK WHICH IS DESIGNATED TO OPERATE = . AT PRESSURES ABOVE 1/2" WATER COLUMN STATIC PRESSURE SHALL BE SEALED AS FOLLOWS: 1. STATIC PRESSURE 1/2 INCH TO 3 INCHES: SEAL ALL TRANSVERSE JOINTS AND LONGITUDINAL SEAMS. SPIRAL LOCK SEAMS IN ROUND AND FLAT OVAL DUCT WORK DO NOT REQUIRE SEALING; HOWEVER, OTHER SEAMS SHALL BE SEALED: 2 STATIC PRESSURE ABOVE 3 INCHES: SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS AND DUCT. WALL PENETRATIONS. 11 NREC FORMS, DUCTING PLANS (BALANCING FEATURES), AS WELL AS VIAQ INFORMATION IS REQUIRED ALONG WITH A MECH. PERMIT AT THE TIME OF THE TENANT IMPROVEMENT .: PERMIT.` 12. PIPING INSULATION SHALL MEET THE REQUIREMENTS OF 1415 OF THE WSEC: TABLE 14-8 MINIMUM PIPE INSULATION INCHES FLUID DESIGN '-',1 y„ ,!,,y J'. T OPERATING MIR ;..1-1/2_>B • : RM1OEMilF) CONOUCIMIY Btu*in•r t MEAN RATING IBR. 'F <t . 1 to < 1-1/2 to <4 . 4 to <8 I HEATING SYSTEUS (SIE/IJ, STEAM CONDENSATE AND HOT WAIERj' 2350 0.32-0.34 250 3.0 3.5 3.5 . _ 4.5 4.5 251-350 0.29-0.32 200 2.0 . 3.0 2.5 3.5 3.5 201-250 027-0.30 150:. 2.0 2.0 . 2.5 2.5 ' 2.5 141-200 025-029 " 125 1.5 1.5. 1.5 2.0 2.0 105-140 022-0.28 . 100. 1.0 1.0 1.5 1.5 1.5.. rill 0 -0. 00 I 1.0 1 1,0 • 1 1.5 . 1 1.5 I 11 5ysR (CHILLED 0A1ER� BRINE AND 40- 40- 80. 0.22-028 - 100 1.0 ' 1.0 1.5 1.5 1.5 1) S40 022-028 100 1.0 1.5 . . 1.5 1.5 2.0 2. PIPING INSULATION NOT REQUIRED BETWEEN CONTROL VALVE AND COL ON RUT/OUTS WHEN CONTROL VALVE IS LOCATED WITHIN 4 FEET OF COIL AND PIPE SGS: IS < 1'. I ttk - AIR CONDITIONING =HEAT PUMPS - REFRIGERATION - CONTRACTOR'S LICENSE NUMBER: UNIVERI 159RF` AUBURN: . (253) 939-5501 • ., TACOMA: (253)922-3141 SEATTLE: . (253) 839-2126 FAX: (253) 735-3432 P.O. BOX 614 - AUBURN, WASHINGTON 98071 ©UNIVERSAL REFRIGERATION DRAWING -2001 z 0 1 -- cc U ..W 0 0 W cc PERMIT ISSUE CO T-. CORRECTION .LE I I ER REVISIONS CO T co N FILCOPY Permit No. ref Plan mview approval is subjeg subjectto atW ions. A; rwl of construction documents not authorize th: . tion of any ;; , . _ •axle or ordname. Receipt of iapproved F'-:;� :By '� 1. RELOCATE AND INSTALL (2) EXISTING EVAPORATOR COILS. .. 2 RELOCATE AND INSTALL (2) EXISTING CONDENSING UNITS. 3 INSTALL REFRIGERATION PIPING. EXTERIOR WAREHOUSE WALL EQUIPMENT LOCATED AND HANGING FROM CEILING OF 2ND COOLER O EQUIPMENT LOCATED AND MOUNTED ON TOP OF 2ND COOLER )OFTOP/INDO OR REFRIGERATION EQUIPMENT SCHEDULE REFRIGERANT CU -1 LARKIN LZTO4M6D W.I. COOLER #2 TYPE R -404A QUANTITY 20 LBS.* MCA MOCP DIMENSIONS (LxWxH) WEIGHT 4.0 460/3/60 29.0 CU -2 EC -1 LARKIN LARKIN LZTO4M6D MLT6310 EC -2. LARKIN MLT6310 .. W.I. COOLER #2 R -404A 20 LBS.* 4.0. 460/3/60 29.0 SEPARATE PERMIT REQUIRED FOR: o lvtiebanteat GioEiectrical plumbing as Piping y of Tukwila 31 '"''NG DIVISION PROJECT START DATE: RECEIVED CITY OF TUKWILA JUN 1 4 2013 r. P RMIT:CENTER DRAF=TER DESIGNER: PROJECT MANAGER: 5/15/13 CFN CS` CS 35 PROFILE UINT COOLERS PROFILE UINT COOLERS .25 460/1/60.• 3.0 16.8 16.8 460/1/60 3.0 30-1/4 x 42-1/2 x 29-3/4 95-5/16 x 15-1/2 x 23-1/4 95-5/16 x 15-1/2 x 23-1/4 317 LBS. 210 LBS. * RECEIVER 90% FULL .' NOTE: These plans are diagrammatical only: Please verify aII dimensions at job site.. END NO CITY APPROVAL l SHEET NUMBER: • AIR.CONPITIONING - HEAT PUMPS. REFRIGERATION , ' CONTRACTO(j'S LICENSE NUMBER: ;•.; ` ' ' ; UNIVERI 159RF. '. AUBURN; (253)939-5501.., •TACOMA[:, • (253) 922-3141 SEATTLE:::: (253) 839-2128' FAX: ' . (253) 735-3432 P.0, BOX 814:- AUBURN; WASHINGTON 98071 QUNIVERSAL REFRIGERATION DRAWING 2001 ' ; • ; CHOR SYSTE AP. COOLER ATTACHMENT SYSTEM DOTE: These plans are :diagrammatical only...: Please•verify all dimensions at job site.