Loading...
HomeMy WebLinkAboutPermit M13-092 - MONEY TREE - ALTERATIONMONEYTREE 6720 FORT DENT WY M13-092 City tdTukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Project Name: MONEY TREE Permit Number: M13-092 Issue Date: 05/29/2013 Permit Expires On: 11/25/2013 Owner: Name: JOHN C RADOVICH LLC Address: 2835 82ND AVE SE #300 , MERCER ISLAND WA 98040 Contact Person: Name: PAUL JOSEPH Address: 4426 221 PL NE , REDMOND WA 98053 Email: PCLIMATE AOL.COM Contractor: Name: PERFECT CLIMATE INC Address: 4426 221 PL NE , REDMOND WA 98053 Contractor License No: PERFECI022D5 Phone: 425 260-6955 Phone: 206-977-7353 Expiration Date: 03/12/2014 DESCRIPTION OF WORK: RELOCATE (3) VAV UNITS AND REPLACE (4) DIFFUSERS WITH NEW Value of Mechanical: $3,500.00 • Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied 'th, The granting of this permit does not pres construction or the p back of this permit Signature: Fees Collected: $233.13 International Mechanical Code Edition: 2009 Date: OS -(f-1 113 ed this permit and know the same to be true and correct. All provisions of law and ordinances hether specified herein or not. e to give authority to violate or cancel the provisions of any other state or local laws regulating ormance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the Date: ��z/ 7 J Print Name: 0 1441 j 1 72-75 i '7/f This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. __. I. 14A RA1 -JQ9 Printed: 05-29-2013 PERMIT CONDITIONS Permit No. M13-092 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 6: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 7: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 9: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. RA1'Z ACi7 Printari• nc-7Q-9m1 CITY OF TUKWJ Community Developmeh. _lepartment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.Tul:wilaWA.aov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** Site Address: 6 ac.) 1 U\ ' l WfAy Tenant Name: fviokpeN King Co Assessor's Tax No.:29 C l j U- 011 Suite Number: PROPERT)(. WNE Name: JC R oDV\C Address: 2-W D Aue 10j City: e State: Zip4 sol CO ACT PE SO ea on peri n �i mpt pro ect Name: KA -0,\ OC -E-'0 1'1 Address: S5- 7L Y1 City: )2_&..-D State: LA/9ZiP9 bo S 3 Phone: y2s2L(2- b Fax: S3 Email: "PC_L)mei (4,)yorpL, Cc, r-\ Floor: New Tenant: ❑ Yes ❑.. No MECHANICAL CONTRACTOR INFORMATION,; - Company Name: iLc%--'C CLI Yh -7---- l n., Address: l % ZG 2 -- �" 7 N� City: State: Zip: , )2- )T) 01,7 ..A.- A (. 5 v s3 Phone: Lj 2C- 2G I J 9 s c" Fax: Contr Reg No. • Exp Date: 3 / 1-1�' CSo2 -PS / // `/ Tukwila Business License No.: 130.509c339l Valuation of project (contractor's bid price): $ Si) 0 Describe the scope of work in detail: j7� 22_p C.4q-] &. (3) 1,/14- V U nd 4.44- )2C-� Z► C Use: Fuel Type: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement ,,, - Electric ❑ Gas ❑ Other: H.\Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11 docx Revised August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10.000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWN R OR AUTHORIZED AGENT: Signature: r Print Name: /)1,4,..)0.5 TO t Mailing Address: ilt4 Z 6 2-9 1 J) H:\Applications\Forms-Applications On Line\20l I Applications\Mechanical Permit Application Revised 8-9-11. docx Revised: August 2011 bh Date: S - i 6-) 3 Day Telephone: 1-(2S = 260 ` 6 i' cg , Diva,A- 960 s 3 City State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2954900455 Address: 6720 FORT DENT WY TUKW Suite No: Applicant: MONEY TREE RECEIPT Permit Number: M13-092 Status: PENDING Applied Date: 05/17/2013 Issue Date: Receipt No.: R13-01663 Payment Amount: $233.13 Initials: JEM Payment Date: 05/17/2013 12:40 PM User ED: 1165 Balance: $0.00 Payee: PERFECT CLIMATE INC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 9913 233.13 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 186.50 000.345.830 46.63 Total: $233.13 Drinro,d• 7_7m INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 12.. (206) 431-3670 Permit Inspection Request Line (206) 431-2451 4,3 M(3 Project: atie_ Tre-e Type o _Inspection: JU A.-( RA P_C Address: lr,fl20 -or( '2_ `'_ Date Called: Special Instructions: Date Wanted:�� -- ' ('a.m. pm.. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: DRiAATT— ,k4,2179 Ins 1 Date: 3 ` c0t 3 n REINSPECTION FEE REQUIRED: Prior to next inspection, fee must be paid at 6300 So;.lthcenter Blvd:, Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit A413 .)`q PERMIT NO. CITY OF TUKW ILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 R.I. (206) 431-367 Permit Inspection Request Line (206)431-2451 Project: /LP *.., ire. -P Type Rf.Inspection: K,01 l� I f- :' �J- �1V(if) Address: („7 ?..-c) o It 46.3 -- ,a - Date Called Special Special Instructions: Date Wanted: - (2 - `'.m.. a(3 p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: C ,�• Inspector: eUVIcA\ C)0{, n REINSPECTION FEE REQUIRED. Pito to next inspection, fee must be paid at 6300 Southcenter Blvd., Suite 100. Callto schedule reinspection. Date: INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Mi3-a�21 Project; Type of Inspection: /.to U 6, - H /J Me - IMOAft-/ r2 Address: Date Called: G 4----'.;,,1 Special Instructions: Date Wanted ^ /� p:m. Requester: re Phone No: 1 0 Approved per applicable codes. ElCorrections required prior to approval. COMMENTS: 6 IA- . ... 1/40 tc_ c„0,L(Ey- r\F-1-65 44:SL 1 srrA4) 1 -.--Li A- (__` — s di, ; e--0-Th'---e ,k �2 ` 1 G 4----'.;,,1 P off— ( f \.-J,8 , s mom ---- re 1 1 A Inspector: Dates. 36 ,(3 REINSPECTION FEE REQUIRED. Pr"ior!to paid at 6300 Southcenter Blvd.. Suite 100. next inspection. fee must be Call to schedule reinspection. PERMIT COORD CO#. PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-092 DATE: 05/17/13 PROJECT NAME: MONEY TREE SITE ADDRESS: 6720 FORT DENT WY X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: PFJ kJ C �5 x-' • 13 Building Division II Public Works Altif\ 4/1- • Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 05/21/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved ❑ Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 06/18/13 Not Approved (attach comments) ❑ DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople P,r ter Friendly Page i General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name PERFECT CLIMATE UBI No. 601844179 INC Phone 2069777353 Status Active Address 4426 221St PI Ne License No. PERFECI022D5 Suite/Apt. License Type Construction Contractor City Redmond Effective Date 3/25/1998 State WA Expiration 3/12/2014 Date Zip 98053 Suspend Date County King Specialty 1 Heating/Vent/Air-Conditioning And Refrig (Hvac/R) Business Type Corporation Specialty 2 Unused Parent Company License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status PERFEC'054DB PERFECT CLIMATE Construction Contractor Air Conditioning Air Heat,Ventilation,Evaporat 3/2/1995 3/1/1998 Archived DJDEVJD940L8 D & J DEVELOPERS INC Construction Contractor General Unused 6/28/2006 8/28/2011 Expired Business Owner Information Name Role Effective Date Expiration Date JOSEPH, PAUL GNAMATHU President 01/01/1980 Amount Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 CBIC SB4087 03/01/2002 Until Cancelled $6,000.00 03/11/2002 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 11 Hartford Casualty Ins Co 52SBAIK1378 03/01/2013 03/01/2014 $2,000,000.0001/22/2013 10 Hartford Casualty Ins Co 52SBAIK1378 03/01/2012 03/01/2013 $2,000,000.0001/30/2012 9 HARTFORD CAS INS CO 52SBAIK1378 03/01/2009 03/01/2012 $2,000,000.00 02/08/2011 8 HARTFORD CAS INS CO 52SB2895QV 03/01/2008 03/01/2009 $2,000,000.00 03/06/2008 7 CBIC INSSB4087 03/01/2006 03/01/2008 $1,000,000.0002/28/2007 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns : //fnrtress.wa. gov/1ni/bbin/Print.asnx 05/29/2013 IIIB\I-0.0 COVER SHEET.DWG IVIoneytree Phase IIIB Site Plan Scale: NTS E \/ AREA 4 A . ENCLOSURE COURITAV Permit No. M -- 0r\'' Plan review approval is subject to errors and omissions. Approval of construction documents does not authcnho the violation of any adopted code or ordinance. Receipt of approved Copy !edged: By fORI WAY SEPARATE PERMIT REQUIRED FOR: 0 Mechanical Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION REVISIONS No changes shall be made to the scope of work without prior approve! of Tukwila Building Division. f!OTE: Revisions will require a new plan submittal and may include additional plan review fees, City Of IbkwIta BUILDING DIVISION Sheet List Table Sheet Number 1-0.0 1-0.1 I—CS.1 1-1.1 1-2.1 1-3.1 1-4.1 1-5.1 1-6.1 1-7.1 1-8.1 1-9.1 1-9.3 1-10.1 Sheet Title Cover Sheet & Site Plan General Notes & Symbols Exit Plan And Codes Summary Demolition Plan Dimension Plan Floor Plan Demo Reflected Ceiling Plan. Reflected Ceiling Plan Finish Pian And Finish Schedule Enlarged Plans Interior Elevations Construction Details Casework Details Door Schedule Elevations Details (Wood) Code Information: REVIEWED FOR CODE COMPLIANCE APPROVED MAY 2 4 2013 City of u iia BUILDING PROJECT ADDRESS: 6720 FORT DENT WAY SUITE 230 TUKWILA, WA 98188 CONSTRUCTION TYPE: CONST—TYPE IIA FULLY SPRINKLERED (NON QR) OCCUPANCY: 8 TENANT SQUARE FOOTAGE: (area of work) 2,074 SF Building Code Fire Code Energy Code Mechanical Code Electrical Code Plumbing Code Zoning Code Accessibility Code Legal Description: 2009 INTERNATIONAL BLDG CODE (IBC), WAC 51-50 2009 INTERNATIONAL FIRE CODE (IFC), INCL. APPENDIX B&C 2009 WASHINGTON STATE ENERGY CODE (WSEC), WAC 51 —1 1 2009 INTERNATIONAL MECHANICAL CODE (IMC), WAC 51-52 JUNE 22, 2009 WA CITIES ELECTRICAL CODE, PARTS 1 & 3 AS PUBLISHED 8Y WA ASSOC. OF BLDG OFFICIALS 2009 UNIFORM PLUMBING CODE (UPC), WAC 51-56 & 51-57 INCL. APPENDIX CHAPTERS H & L — EXCL. SECTIONS L5—L7 & "LAWN SPRINKLER HEAD" FROM TABLE 6-4 OF APPENDIX L CITY OF TUKWILA 2003 ACCESSIBLE & USABLE BUILDINGS & FACILITIES (ICC/ANSI Al 17.1) WAC 51-50-005 TAX PARCEL #295490-0455 BEGINNING AT HIGHWAY ENGINEER'S STATION P.O.T. (2M) 127 +45.0 ON THE 2M LINE SHOWN ON THE STATE HIGHWAY MAP OF PRIMARY STATE HIGHWAY #1 (SR405) GREEN RIVER INTERCHANGE, SHEET 2 OF 4 SHEETS, ESTABLISHED BY COMMISION RESOLUTION #1192, FEBRUARY 19, 1962, THENCE NORTHEASTERLY AT RIGHT ANGLES. TO SAID 2M LINE NORTH 30'27'06" EAST 218.36 FEET TO A POINT ON A LINE THAT IS PARALLEL WITH, AND 140 FEET (MEASURED AT RIGHT ANGLES) NORTHEASTERLY OF THE SOUTHWESTERLY MARGIN OF VACATED KENNEDY STREET (6TH PLACE S.) AS SHOWN ON THE PLAT OF GUNDAKER'S INTERURBAN ADDITION TO SEATTLE, AS PER PLAT RECORDED IN VOLUME 14 OF PLATS, PAGE 46, RECORDS OF KING COUNTY, SAID POINT BEING THE TRUE POINT OF BEGINNING OF THE PARCEL TO BE DESCRIBED HEREIN, THENCE FROM SAID TRUE POINT OF BEGINNING ALONG SAID PARALLEL LINE NORTH 59'32'54" WEST TO THE BANK OF THE GREEN RIVER, THENCE ALONG THE BANK OF THE GREEN RIVER THE FOLLOWING COURSES: NORTH 38'19'12" EAST TO A POINT LYING SOUTH 30'04'58" WEST 334.53 FEET FROM THE SOUTHWESTERLY LINE OF THE LANDS CONVEYED TO KING COUNTY BY STATUTORY WARRANTY DEED RECORDED UNDER RECORDING NO. 7507300471 AND NORTH 30'04'58" EAST 334.53 FEET TO SAID SOUTHWESTERLY LINE, THENCE ALONG SAID SOUTHWESTERLY LINE SOUTH 59'24'45" EAST 183.62 FEET TO A POINT ON THE NORTHWESTERLY LINE OF THE LANDS CONVEYED TO THE CITY OF TUKWILA BY QUIT CLAIM DEED RECORDED UNDER RECORDING NO. 7410290105, THENCE ALONG LAST SAID NORTHWESTERLY LINE THE FOLLOWING COURSES: FROM A TANGENT THAT BEARS SOUTH 30'53'45" WEST ALONG THE ARC OF A CURVE TO THE LEFT HAVING A RADIUS OF 60.00 FEET AND A CENTRAL ANGLE OF 24'24'42", AN ARC LENGTH OF 13.63 FEET, THENCE TANGENT TO THE PRECEDING CURVE SOUTH 22'08'00" WEST 223.43 FEET, THENCE TANGENT TO THE PRECEDING CURVE SOUTH 30'27'06" WEST 66.52 FEET TO THE TRUE POINT OF BEGINNING, EXCEPT THAT PORTION CONVEYED TO THE CITY OF TUKWILA BY DEED RECORDED UNDER RECORDING NO. 7708040599, SITUATE IN THE CITY OF TUKWILA, COUNTY OF KING,STATE OF WASHINGTON. Vicinity Map: PROJECT SITE Project Team: Property Owner J.0 RADOVICH 2000 124TH AVE. NE., B103 BELLEVUE, WA 98005 425-454-6060 Tenant: MONEYTREE 6720 FORT DENY WAY TUKWILA, WA 98188 206-246-3500 MEAGAN HENDERSON meagan.henderson®moneytreeinc.com Architect: JPC ARCHITECTS, PLLC 909 112TH AVE NE SUITE 206 BELLEVUE, WA 98004 (425) 641-9200 MARK PETERSON — EXT. 340 markp®jpcarchitects.com CLAIRE WIESE — EXT. 351 clairew©jpcarchitects.com General Contractor: BAKER CONSTRUCTION 2711 E. SPAGUE AVENUE SPOKANE, WA 99202 509-535-3668 LIC. NO. #BAKERCD066CZ (t) MoneyTree Phase IIIB Floor 2 6720 Fort Dent Way Tukwila, WA 98188 DESIGN DRAWN CHECKED NO. JM, CCW ccw MP 12-0803 3/07/13 PERMIT SUBMITTAL • RECEIVED CITY OF TUKWILA MAY 1 7 2013 PERMIT Ct .N wer Sheet & Site Plan 1-0.0 © 2012, JPC Architects, PLLC 1 Pen Table: JPC MoneyTree Phase IIIB Floor 2 6720 Fort Dent Way Tukwila, WA 98188 DESIGN JM, CCW DRAWN ccw CHECKED MP NO. 12-0803 3/07/13 PERMIT SUBMITTAL Finish Plan and Finish Schedule 1-6.1 © 2012, JPC Architects, PLLC A B D Finish Specifications FLOORING CPT TYPICAL FLOORING, U.N.O. STYLE NAME: TBD STYLE N0: TBD COLOR N0: TBD BACKING: TBD INSTALLATION: TBD CPT MFR REP.: TBD ACCENT CARPET, U.N.O. MFR: TBD STYLE NAME: TBD STYLE NO: TBD COLOR NO: TBD BACKING: TBD INSTALLATION: TBD VCT MFR REP.: TBD VINYL COMPOSITION TILE MFR: TBD w _� - - w w - - S L O P E OF WORK - OFFICE OFFICE OFFICE OFFICE .......1 _ IOO�I COLOR NAME: TBD 1211 1212 213 250 ---) :-\\ OFFICE COLOR NO: TBD VCT VINYL COMPOSITION TILE MFR: TBD OFFICE I 215 ( - 1 208 ' SERIES: TBD COLOR TBD CT 1 COLOR NOME: TBD CERAMIC TILE MFR: TBD 1 ,_ BREAK ROOM 1 .. •.••••••••. • COLOR NAME: TBD COLOR NO: TBD 1 225 OFFICE OFFICE OFFICE OFFICE 1 OFFIC ST N0: FINISH: TBD TBD STONE TILE MFR: TBD 204 1 219 EXEC ENTRY 217 216 218 OFFICE 1 = II 207 Iiint ifie TYPE: TBD COLOR NAME: TBD ' ❑ �_ i _ _ EIT7 O HALLWAY PANTRY BASE SIZE: TBD OFFICE / 203 120013 1 234 O STORAGE Ei✓ t 21-7 RB1 TYPICAL BASE, U.N.O. 2 9FEC MFR: TBD PRODUCT: TBD COLOR NAME: TBD COLOR N0. TBD ASTM TYPE: TBD TBD F.E.c -- .. — il STORAGE \ / - OFFICE F.E.C. 232 'PROFILE: STORAG 202 /' 230 SERVER R004 WB1 OD BASE, U.N.O. MAILROOM/UPS SHIPPING CTR WORK ROOM l 228 ' '� � GENERAL MFR: TBD PRODUCT: TBD SPECIES: TBD WALL PAINT (TYPICAL U.N.0.) 224 226 OFFICE O 201 / '„i;,,,. Irak MFR: TBD • ❑ Ai Mir ACCENT COLOR NAME: TBD COLOR N0: TBD SHEEN: EGGSHELL SEMI -GLOSS @ WET AREAS WALLS : ■ EXEC CONF ROOM _ / Q TBD J 222 RECEPTION IL. / ® ® CFR: TBD ME COLOR NOTBD EGGSHELL, SEMI -GLOSS 0 WET AREAS WALLCOVERING: TBD 200A .44SHEEN: ® ® MFR: TBD STYLE: TBD COLOR NAME: TBD INSTALLATION:. TBD WALL TILE CONFERENCE ROOM �.� 220 /� ---....„,..,o O / ` ' p MFR: TBD COLOR NAME: TBD COLOR N0: Teo FINISH: TBD WALL PANELING �-- REVIEWED FOR CODE COMPLIANCE 77 /'� APPROVED Z MAY 242013 1--� / Tukwila Q CASE SPECIES: TBD FINISH: TBD LOCATION: TBD WORK vAu ■ City of / BUILDING DIVISION / I F I n S h P l a n PL1 PLASTIC LAMINATE MFR: TBD TBD COLOR NOCOLORME: TBD LOCATION: TBD Scale: 1/8"=1'-0” / PL2 PLASTIC LAMINATE MFR: TBD COLOR NAME: TBD COLOR NO: TBD LOCATION: TBD Finish Notes: 1 SS1 ( SOLID SURFACING 1. ALL AREAS TO RECEIVE CARPET AND BASE AS SCHEDULED U.N.O. 9. ALL INTERIOR PARTITIONS, CEILING FINISHES AND TRIM OF PUBLIC AREAS TO COMPLY WITH CLASS 1 MATERIAL CLASSIFICATION; FLAME 2. ALL AREAS TO RECEIVE RB -1 U.N.O. SPREAD RATING 0 TO 25, SMOKE DEVELOPED 200. ALL INTERIOR WALL AND CEILING FINISHES AND TRIM OF NON-PUBLIC AREAS TO COMPLY 3. ALL WALLS & PARTITIONS TO RECEIVE P-1 U.N.O. WITH CLASS 2 MATERIAL CLASSIFICATION; FLAME SPREAD RATING 26 TO 75, SMOKE DEVELOPED 450. 4. PREP ALL EXISTING FLOOR SURFACES TO RECEIVE NEW FINISHES AS SCHEDULED. 10. FLOOR COVERINGS OF .PUBLIC AREAS TO MEET CLASS A INTERIOR FLOOR FINISH REQUIREMENTS; CRITICAL RADIANT FLUX OF 0.45 WATTS 5. PROVIDE PAINT APPLICATION APPROPRIATE TO THE SUBSTRATE TO PER SQUARE CENTIMETER OR HIGHER, FLOOR COVERINGS OF4.5112.. WHICH IT IS TO BE APPLIED. NON-PUBLIC AREAS TO - MEET CLASS 8 INTERIOR FLOOR FINISH REQUIREMENTS; CRITICAL RADIANT FLUX BETWEEN 0.22 WATTS PER 6. ALL EXPOSED GYP. BD. SURFACES, BOTH EXISTING AND NEW, :ARE. TO SQUARE.; .CENTIMETER AND 0.44 WATTS PER SQUARE CENTIMETER. RECEIVE NEW PAINT FINISH. PREP ALL SURFACES AS REQUIRED- FOR =' NEW PAINT FINISH. PROVIDE ONE PRIME COAT PLUS TWO FINISk 11. CARPET. INSTALLATION TO MEET THE GUIDELINES OF THE CARPET AND COATS r RUG,,..INSTITUTE-CRI CARPET INSTALLATION STANDARD -CURRENT EDITION. .4., 7. CHANGES IN FLOOR °MATERIALS -THAT- 'OCCUR' AT• FRAMED DOOR ::: 12. PROVIDE FINISHED SCRIBE STRIPS AND FINISHED MILLWORK EDGES TO OPENINGS SHALL OCCUR AT THE CENTERLINE OF THE DOOR IN THE CREATE A FINISHED REVEAL CONDITION WHERE MILLWORK COUNTERS, CLOSED POSITION.- ' w. - • ,r,..'.,-.. - CABINETS, ETC. "ABUT" ADJACENT. PARTITION CONSTRUCTION. ALL EXPOSED REVEAL SURFACES AND EDGES TO HAVE SAME PLASTIC 8. ANY DECORATIONS USED SHALL BE NON-COMBUSTIBLE OR FLAME - LAMINATE FINISH AS THE CASEWORK ITEM THEY "ABUT". RETARDANT TREATED IN AN APPROVED OF MANNER (CURTAINS, DRAPES, SHADES, HANGINGS, ETC.) 13. CONTRACTOR TO CLEAN AND REPAIR ALL EXISTING EXTERIOR GLAZING AND INTERIOR RELITE MINI -BLINDS WITHIN THE WORK AREA. MFR: TBD COLOR NAME: TBD COLOR NO: TBD LOCATION: TBD - (2) 9 2... tik RECEIVED .. CITY OF TUKWILA MAY 1 7 2013 PERMIT CENTER MoneyTree Phase IIIB Floor 2 6720 Fort Dent Way Tukwila, WA 98188 DESIGN JM, CCW DRAWN ccw CHECKED MP NO. 12-0803 3/07/13 PERMIT SUBMITTAL Finish Plan and Finish Schedule 1-6.1 © 2012, JPC Architects, PLLC • ti\V C-Al\ACAL_ 4\3 : REVIEWED FOR CODE COMPLIANCE APPROVED MAY 24 2013 City of Tukwila BUILDING DIVISION 111 3%-.0 RECEIVED CITY OF TUKWILA MAY 1 7 2013 PERMIT CENTER 24X:4 CLIA. REVISIONS • BY •10311M111. 'Oa •Ln 3 6.) 0 3 LI Date 5 Scale yd!, Drawl Job 10 3