Loading...
HomeMy WebLinkAboutPermit M13-099 - COSTCO - ALTERATIONCOSTCO 400 COSTCO DR M13-099 City otkukwila 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: httn://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 2523049063 Address: 400 COSTCO DR TUKW Project Name: COSTCO Permit Number: M13-099 Issue Date: 07/02/2013 Permit Expires On: 12/29/2013 Owner: Name: COSTCO WHOLESALE CORPORATIO Address: PROPERTY TAX DEPT 006 , 999 LAKE DR 98027 Contact Person: Name: Address: Email: Contractor: Name: Address: BILL ZORNES 19430 68 AV S, SUITE B , KENT WA 98032 BZORNE S @ KEYM E C HANICAL. C OM Phone: 253-872-7392 KEY MECH CO OF WASHINGTON Phone: 253-872-7392 19430 68 AV S, SUITE B , KENT WA 98032 Contractor License No: KEYMEW*240NZ Expiration Date: 04/01/2015 DESCRIPTION OF WORK: REMOVE EXISTING REFRIGERATED DISPLAY CASES WITH NEW. TIE INTO EXISTING REFRIGERATION SYSTEM Value of Mechanical: $30,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $551.06 International Mechanical Code Edition: 2009 Date: 07% 43 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: Date: Z ` This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Al'2 (tCIO Dr;n4.A• PERMIT CONDITIONS Permit No. M13-099 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-099 Printed: 07-02-2013 CITY OF TUKWI. Community Developmo. Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION LE) COs -co 1)Z, Site Address: 11-6...0 zC-o 4 (712 King Co Assessor's Tax No.: Tenant Name: GGG✓TGp \`/ Suite Number: Floor: New Tenant: ❑ Yes [ 1 PRQPERTY Name: Gos-�-Go \Vuo..L. Address: City:144.6.G01"141.3.4 State: \VA Zip: C� O ACT P co lin Name: �t t_l.-. .e:,t2.4--.1 le S Address: City: State: Zip: Phone: 204' Si G' 36rI Fax: Email: rpzorv.Los. bc,ei t►meeha‘•t Get' . 44o -A^ Valuation of project (contractor's bid price): $ / CC -90 Describe the scope of work in detail: 12.e1 -"OV EX ( ,T t 4- 161 C 1 1Z7 t S p4 -a`( G •� `� 5 \\/ 1714 h! ENV. -1-1 E 1 v4TO IE.xl'5 Tl t..l i S -t' STS Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement *❑� Fuel Type: Electric ❑ Gas ❑ Other: H.\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-11 docx Revised. August 2011 bh Page 1 of 2 MECHANICAL ;CONTRACTOR INFORMATION':, Company Name: �1Esf, lV. .t -1•.d l..t t G./S. L. - Address: ,q 4 3o • 66'r-. �6.q . S , S u tT City:. �,T, State: \ VA ZiP: 032 Phone: . Fax: 5-1g:f(2•..17.ftt 253.8Z2.-13"€., Contr Reg No.:. 1S.YMkV4O147xp Date: t. Tukwila Business License No.: Valuation of project (contractor's bid price): $ / CC -90 Describe the scope of work in detail: 12.e1 -"OV EX ( ,T t 4- 161 C 1 1Z7 t S p4 -a`( G •� `� 5 \\/ 1714 h! ENV. -1-1 E 1 v4TO IE.xl'5 Tl t..l i S -t' STS Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement *❑� Fuel Type: Electric ❑ Gas ❑ Other: H.\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-11 docx Revised. August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cool ing system lTh Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct lTh Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment lTh Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OW Signature: OR AUTHORIZED AGENT: Print Name: TU< 4.4��- Date: 6 A/e6( Day Telephone: f 55 -eT2 ' 7 51 Z, Mailing Address: (14 3o • 81-4' QJ . tT� I-1: \ Applications \ Forms -Applications n:\Applications\Forms-Applications On Line\201 I ApplicationsUvlechanical Permit Application Revised 8-9-11 docx Revised: August 2011 bh \\/ 4 r 80 3 2- State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 2523049063 Address: 400 COSTCO DR TUKW Suite No: Applicant: COSTCO RECEIPT Permit Number: M13-099 Status: PENDING Applied Date: 06/03/2013 Issue Date: Receipt No.: R13-01783 Payment Amount: $551.06 Initials: WER Payment Date: 06/03/2013 01:10 PM User ID: 1655 Balance: $0.00 Payee: ALLEN TURNER TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 005931 ACCOUNT ITEM LIST: Description 551.06 •Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 440.85 000.345.830 110.21 Total: $551.06 o.into,1• na_m_)n1z INSPECTION 0. INSPECTION RECORD Retain a copy with permit I"l 3 M®O PERMIT NO. CITY OF TUKWILA BUILDING DIVISION (206) 431-367 6300 Southcenter Blvd., #100, Tukwila. WA 98188 Permit Inspection Request Line (206) 431-2451 Project: ( .P) S t Lica Type oofflInspection: 1 . J.i AA Ake_ • Ad�'ress: / _ �-7-y � 0(� Go 5 I C..B � 4_ Date Called:. � -� 6 - Speci I instructions: — �( ,. �� (-18/Requester: JP- 2 P,Fr?�- uAn Date Wanted: a r f 0 ---7 —( P.m. iD 06 Phone o — 35((v3 0 63 G pproved per applicable codes. Corrections required prior to approval. COMMENTS: Inspe or: Date: fro ;-1�. n REINSPECTION FEE REQPIREF: for to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. r PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER M1;,.3-099 DATE: 06-03-13 PROJECT NAME: COSTCO SITE ADDRESS: 400 COSTCO DR X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issued DEPARTMENTS: 1112ingitgeon Public Works ❑ Fire Prevention Structural Planning Division Permit Coordinator • DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete n DUE DATE: 06-04-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required ❑ No further Review Required n REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: Approved n Approved with Conditions Notation: REVIEWER'S INITIALS: DATE: DUE DATE: 07-02-13 Not Approved (attach comments) n .Permit 'Center, Use On/y CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople4inter Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name KEY MECH CO OF WASHINGTON UBI No. 600196154 Phone 2538727392 Status Active Address 19430 68Th Ave S Ste B License No. KEYMEW'24ONZ Suite/Apt. License Type Construction Contractor City Kent Effective Date 8/9/1976 State WA Expiration Date 4/1/2015 Zip 98032 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Business Owner Information Name Role Effective Date Expiration Date HEISLER, ROBERT L Cancel Date 01/01/1980 Bond Amount LEONARD, FRANK W 25 01/01/1980 023011682 023011682 SANDAHL, LEE F Until Cancelled 01/01/1980 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 25 MUTUAL INS LIB10 CO 023011682 023011682 04/01/2009 Until Cancelled $12,000.0003/23/2009 9 INSURANCE CO OF THE WEST 1886384 04/01/2003 04/01/2009 $12,000.00 03/31/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 25 Hartford Fire Ins Co 52UENOE0154 03/31/2013 04/01/2014 $1,000,000.0003/28/2013 24 Phoenix Insurance Company, The DTC0527D1631PHX12 03/31/2012 03/31/2013 $1,000,000.0004/02/2012 23 OLD REPUBLIC GENREAL INS A1CG00081100 03/31/2011 03/31/2012 $1,000,000.0003/31/2011 22 TRAVELERS PROPERTY CAS INS CO DTC0526D7003TIL10 03/31/2009 03/31/2011 $1,000,000.0004/02/2010 21 TRAVELERS INDEMNITY CO OF AME DTC0526D70031ND08 03/31/2008 03/31/2009 $1,000,000.0003/18/2008 20 TRAVELERS INDEMNITY CO DTEC0526D7003INDO7 03/31/2007 03/31/2008 $1,000,000.0003/28/2007 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns://fortress.wa. i?ov/1ni/bbip/Print.aspx 07/02/2013 • cq 747 i H • FIRE PROTECTION STAND PIPES FIRE HYDRANT . GAS VALVE RECPT. OPTICAL KIOSK IL PHOTO 1 I EXIST. EXIST. CE EXIT 111•1P, Hi? HEH coulee OFFICE OFFICE OFFICE OpFICE OFFICE WO EN RESTPOOM TIRE INSTALLATION BAKERY COOLER BAKERY PREP. n1 1 Fiat; - JEWELRY ASE EMPLOYEE BREAKROOM PROJECT DATA EXISTING PROPOSED MEAT ISLAND 56' M-1 PROJECT SCOPE DEMOLISH: 1. DEMOLISH (1) 56' M-1 ISLAND. 2. DEMOLISH WINE TABLES/RACKS, INSTALL: 2. INSTALL (1)56' ITT M-1 ISLAND. ITTITITItTITITTITTTRI L;`--ETTT++ i:E++++++V+++] iDIEEEPIE C[1E1E4E-II] EIHE BAKERY FiCOOLER BAKERY FREEZER MECHANICAL ROOM NOTE: EXISTING CONDITIONS TO BE FIELD VERIFIED. NOTE: CONCEPT PLAN - NOT FOR PERMITTING OR CONSTRUCTION tjIHEIEIE UCIIEEE II] kt 18' tO POS COOLER NEW 48' M-1 ISLAND AREA OF WOR EEE ST. POS FREEZER MEAT COOLER 18' HT. RECEIVING tO FR MEAT PREP. EIHEI EiEEE4I] EiEEIE 11 u -11 II II 11 011111 1111 NOU §1011 411411 1 1 [ VA mirarials• Li ul HH EH 144 1 II1 1 1111 1111 H FH m 1111 1111 HH 141-1 141-1 II gil—±441 1—H HH HH H .11H HH HH HH H HH HH 1 Y 1 HH 17'H HH HH II I 1 Y 1 EXIST. SCRUBBE 81, eJ Ram rrtview approval is kr Of construction et :ton at any tit Loproved Field Copy PROJ BUILDING DATA: BUILDING AREA ABANDONED OPTICAL 1ST FLOOR ABANDONED OPTICAL 2ND FLOOR TIRE INSTALLATION EXIST. TOTAL BUILDING • VERSTr DELI COOLER GROCERY RACKS CENTER SECTION HARDLINE RACKS 193,602 S.F. 13,272 S.F. 13,272 S.F. 2,400 S.F. 222,496 S.F. 112 13,963 S.F. 167 NOTES: EXISTING CONDITIONS TO BE FIELD VERIFIED. E] REAGH-IN DOORS ;111 litaajia 411141_4144 414141 41114 1144,4111411414411.41,414114_411441..10,414 ,4111.114 _4414 _44111/1 4414 441.,„ 4441 , [LILL rt H TTT1 PRODUCE STORAGE POTAT CHIP AREA dbWiR SUPPLY AREA FFFFIC ROO COMPACTOR ITTTTT EXIST. CHILLER /— EXIST. BAILER & COMPACTOR WATER METER Anx VALVE IIIEW 111111111111 SEPARATE REQUIRE FOR No ch s r -f work L:Tirrtay in COSTCO VVHOLESALE TUKWILA, WASHINGTON lecificar Dgumbing r_tity of Tukwila Bi ;ii_DING DIVISION REVISIONS hall be made to Um ut prior approval ci la Building Division. require a new plan additional plan review fees. REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 5 2013 City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUN 0 3 2013 PERMIT CENTER t113-0?6/ CONCEPT PROPOSED PLAN OPTION 1 MAY 14,2013 0 5' 10' 20' 40' LOCATION 006 1160 SAXON DR. TUKWILA, WA 98188 1110 112TH AVE. NE 1 SUITE 500 BELLEVUE, WA 1 B8004 t 425.463.2000 1 0425.463.2002 93-0440 MAY 14, 2013 CONCEPT PROPOSED PLAN OPTION 1 DD21 01 �41 E, v OUTLINE OF EXISTING CANOPY 500' OPTICAL KIOSK OFFICE OFFICE TIRE INSTALLATION viHr? BAKERY COOLER 10' HT. BAKERY PREP. EMPLOYEE BREAKROOM PROJECT DATA EXISTING PROPOSED MEAT ISLAND 56' M-1 PROJECT SCOPE DEMOLISH: 1. DEMOLISH (1) 56' M-1 ISLAND. 2. DEMOLISH WINE TABLES/RACKS. INSTALL: 1. INSTALL (1) 48' M-1 ISLAND. 2. INSTALL (1) 56' D!T M-1 ISLAND. C====: MECHANICAL ROOM NOTE: EXISTING CONDITIONS TO BE FIELD VERIFIED. NOTE: CONCEPT PLAN - NOT FOR PERMITTING OR CONSTRUCTION POS COOLER 18' HT. SHOP -It MEAT 20' HT. 8' M-1 20' 0-5 IST. TRANS. POS FREEZER 18' HT. MEAT COOLER 18' HT. EIIIIII _+++++++++++f E++ MEAT PREP. OFFICE \ \dV vr.ry )'w\r 'tip„ -1 11 1 lu rit-1H 21--i !! i thtl11. dN q11 tl F===9 P===9 k=reil c-PO"C-- —Q 00 if ND11 VAY hOn O IIIIIIIIIE+E3 DELI PREP. TORAGE oVERSTO( DELI COOLER m m 1--1-1 m m F19---99- 1 n ti Ili f—u _ 1III IIII I1 I IIII III 1,7 1 11 1 1111 1111 1111 IIII IIII IIII III III rr. IIII IIII 1II IIIIIIII J� III I III I II III I 11H 1111 1111 1111 1111 - 1111 1111 11 1 1111 1 111 45'1 I Y I 4411 Y H I I -1-4---- W W W W HH- HII HII HII H HH- HH- H H- 54 REACH -IN DOORS iA(1 iriiiii�AIIillirid!!i iiii 4 l'Yii , _ .... ..„.„ _,,,....-_,,-,_ ,41 maw _,• I limom -ImmMIN :i.' I. 1 H. l I AN 1 164'-8 C=CC C ITTTTTTI I SHOP -IN PRODUCE 18' HT. POTAT• CHIP AREA EXIST. CHILLER PAD FIRE PROTECTION STAND PIPES SUPPLY AREA FIRE o HYDRANT GAS VALVE COMPACTOR WATER METER WATER VALVE TELEPHONE CLOSET BATTERY CHARGER 1111141111101, 11111}1111,111111111111111611-1.1 EXIST. BAILER & COMPACTOR PROJECT DATA BUILDING DATA: BUILDING AREA ABANDONED OPTICAL 1ST FLOOR • ABANDONED OPTICAL 2ND FLOOR TIRE INSTALLATION EXIST. TOTAL BUILDING 193,602 S.F. 13,272 S.F. 13,272 S.F. 2,400 S.F. 222,496 S.F. RACK COUNT: GROCERY RACKS CENTER SECTION HARDLINE RACKS 112 13,963 S.F. 167 NOTES: EXISTING CONDITIONS TO BE FIELD VERIFIED. 1A13---017 C=CC=CC=CC MAINTE. ONCE COSTCO WHOLESALE TUKWILA, WASHINGTON ■IIIIIIIIII,iiIRIIIIII111111I _= I.1 REVIEWED FOR CODE COMPLIANCE APPROVED JUN 2 5 2013 City of Tukwila BUILDING DIVISION CONCEPT DEMO PLAN OPTION 1 RECEIVED CITY OF TUKWILA JUN 0 3: 2013. PERMIT CENTER MAY 14, 2013 0 5' 10' 20' 40' TUKWILA, WA LOCATION 006 1160 SAXON DR. TUKWILA, WA 98188 1110112TH AVE. NE 1 SUITE 500 BELLEVUE, WA 1 98004 t 425.463.2000 1 f 425.463.2002 93-0440 MAY 14, 2013 CONCEPT DEMO PLAN OPTION 1 DA21-01