Loading...
HomeMy WebLinkAboutPermit M13-101 - PAPER DESTINY - ALTERATIONToT-ETJ/\T TIVY1i ITHINHD11,1110s iLti AMILLSaU }IEIJVd City otkukwila • Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 271 SOUTHCENTER MALL TUKW Project Name: PAPER DESTINY Permit Number: M13-101 Issue Date: 06/28/2013 Permit Expires On: 12/17/2013 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: AMY SHYMANSKI Address: 319 ELAINES CT , DODGEVILLE WI 53533 Email: AMY@PERMIT.COM Phone: 608-319-2096 X8 Contractor: Name: HARDESTY & ASSOCIATES INC Phone: 949-723-2230 Address: 500 E BALBOA BL , NEWPORT BEACH CA 92661 Contractor License No: HARDEAI066PP Expiration Date: 11/17/2013 DESCRIPTION OF WORK: HVAC FOR TENANT IMPROVEMENT Value of Mechanical: $7,900.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $281.56 International Mechanical Code Edition: 2009 Date: I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: .S tr fol<<r Date: G a gy'3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. 111401 4A4 D.in{ed• na_9Q Oi1'1 Q • 1 PERMIT CONDITIONS Permit No. M13-101 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: Water heaters shall be anchored or strapped to resist horizontal displacement due to earthquake motion. Strapping shall be at points within the upper one-third and lower one-third of the water heater's vertical dimension. A minimum distance of 4 -inches shall be maintained above the controls with the strapping. 6: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 8: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 9: ***FIRE DEPARTMENT CONDITIONS*** 10: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 11: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) (ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 12: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 13: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 15: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 16: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 17: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 18: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 19: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IMC -4/10 M13-101 Printed: 06-28-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. Project No. Date Application Accepted: Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: SiteAddress:c2% 3t.rihli, 4",- /1{0// -1-044),. Suite Number: (((o0 Tenant Name: F�1 ( layt5i -11 PROPERTY OWNER Name: n 4friv 5hyr i n.5ki Address: 3/9 Ft ? rtn5 7 i Name: /L cito, ` 1 Phone:&g,9_80,zog,Fax:66S'.3j g_ g6 1/ Email: QvV -/( Ibt✓Yli4 - t ,\vY1 Address:/9 e(OinO5 aLt t1 - City: [\ 1_2Viilp State: ,.1 Zip:5353 CONTACT PERSON — person receiving all project communication Name: n 4friv 5hyr i n.5ki Address: 3/9 Ft ? rtn5 7 i City:C\ eat) State:, 1 Zip:535,w Phone:&g,9_80,zog,Fax:66S'.3j g_ g6 1/ Email: QvV -/( Ibt✓Yli4 - t ,\vY1 New Tenant: Floor: .Yes ❑ ..No MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: ' State: Zip: Phone: Fax: - Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Use: tvt-tt-;aY -/w-f— (-/Lia Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas ❑ Other: H:WpplicationsWorms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu 5 Floor furnace / Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm 5 Evaporator cooler / Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial gx 1-5 kil6 C alp 14,100 Cxliuu51 F ✓► ) Unit Type Qty Fire damper Diffuser 5 Thermostat / Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu • 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING 0 .L R OR UTIORI L % AGE T: Signature: II__ Print Name: /7 n f31 y Yl y /I'n5k Mailing Address: ,3)9 a") 05 (eX.t.ik H:Wpplications\Forms-Applications On Line\2011 Applications\Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Date: 6-',O Day Telephone: (160S- 3/9- ck)9(.0 t l City C�J1 5-55'5 State Zip Page 2 of 2 • wq� City of Tukwila Department of Community Development a r G1 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT • Parcel No.: 9202470010 Permit Number: M13-101 Address: 271 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 06/04/2013 Applicant: PAPER DESTINY Issue Date: Receipt No.: R13-02023 Initials: WER User ID: 1655 Payment Amount: $225.25 Payment Date: 06/28/2013 10:39 AM Balance: $0.00 Payee: HARDESTY & ASSOCIATES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 80344 225.25 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 225.25 Total: $225.25 Drintari. AR_7R_7A14 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M13-101 Address: 271 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 06/04/2013 Applicant: PAPER DESTINY Issue Date: Receipt No.: R13-01794 Payment Amount: $56.31 Initials: WER Payment Date: 06/04/2013 11:15 AM User ID: 1655 Balance: $225.25 Payee: RICHARD R JENCEN ASSOCIATES TRANSACTION LIST: Type Method Descriptio Amount Payment Check 29371 56.31 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 56.31 Total: $56.31 17).;..1...4• AC AA 'IAI INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (2.— (206) 431-3670 Permit Inspection Request Line (206) 431-2451 11113 - Project: PAP R D r .tu1-( Type of Inspection: S neo icE S htd t &) Address: a-7 ( se. IA1 AL/ Date Called: • Special Instructions: Date Wanted: -7, Z 5 - I a.m.' p.m. Requester: Phone No: .53-705-c573 Approved per applicable codes. Corrections required'prior to approval. COMMENTS: Gti S 11711 Afti/sla c-(e/t-lkJt1 NSPECTION FEE RE !RED. Prio to nex inspection, f must be id at 6300 Southcenter Blvd., Suite 1 00. Call to schedule reinspection. INSPECTION RECORD f Retain a copy with permit rs,A 13 -101- INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 le— (206) 431-3670 Permit Inspection Request Line (206) 431-2451 E) Protect: _ a\ F2 ESI-t'I3`-1 Type of Inspection: RCAicr4-11v Address: a.7 i e 110 A I—L._ Date Called: Special Instructions: - Date Wanted:Wim' _ 1 � — 1 -2-? p.m. Requester: Phone No: a-953--nc -oc7 1y(I Approved per applicable codes. OCorrections required prior to approval. COMMENTS: Dae: n�REI SPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION NUMBER '.INSPECTION RECORD Retain a copy with permit PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: Gape.- 13e6 in 'y Sprinklers: Type off, Inspection: wire lei d- FA FTnc l ;Address:/l Suite #: 27/ .v, /hc�-,-/-7,y- P.)0/1/ Contact Person: Special Instructions: Occupancy Type: Phone No.: !c. Approved per applicable codes. Corrections required prior to approval. COMMENTS: Sprinklers: 0(4'r_h 1 /� -21 " 1- r ha[ 1 ) 065 G� Y irt- u )--/rA/01 �1 hUI ya55. - °K Occupancy Type: \. Needs Shift Inspection: Sprinklers: Fire Alarm: Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: (1\ 1 Fpi s---‘( Date: )/-z-,43 Hrs.: , $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 • PERMIT COM COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-101 DATE: 06-04-13 PROJECT NAME: PAPER DESTINY SITE ADDRESS: 271 SOUTHCENTER MALL X Original Plan Submittal Response to Correction Letter # Response to Incomplete Letter # After Permit Issued DE ARTM TS`,n B ilding Division U�Y� Public Works n C 6Q/kg t17 ire Prevention I Planning Division Structural Permit Coordinator 1 DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 06-06-13 Not Applicable n Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUES/THURS ROUTING: Please Route X( Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07-04-13 Approved ❑ Approved with Conditions1K Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Peer Friendly Page • General/Specialty Contractor A business registered as a construction contractor with Lal to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name HARDESTY ft ASSOCIATES INC UBI No. 601423943 Phone 9497232230 Status Active Address 500 E Balboa Blvd License No. HARDEAI066PP Suite/Apt. License Type Construction Contractor City Newport Beach Effective Date 10/17/1994 State CA Expiration Date 11/17/2013 Zip 92661 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status HARDESI099DG HARDESTY a STONE INC Construction Contractor General Unused 3/7/1991 7/2/1993 Archived Business Owner Information Name Role Effective Date Expiration Date HARDESTY, ROBERT D Cancel Date 01/01/1980 Bond Amount HARDESTY, ROBERT E 7 01/01/1980 wa13466 HARDESTY, WILLIAM 5 Until Cancelled 01/01/1980 HARDESTY, LORI A 10/30/2012 01/01/1980 PLATTE RIVER INS CO ALLEY, RICHARD Agent 01/01/1980 09/01/2009 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 7 MERCHANTS BONDING CO (MUTUAL) wa13466 09/08/2009 Until Cancelled $12,000.0009/14/2009 10/30/2012 6 PLATTE RIVER INS CO 40069657 09/01/2003 Until Cancelled 09/01/2009 $12,000.00 09/08/2003 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 18 Scottsdale Ins Co BCS0028986 10/25/2012 10/25/2013 $2,000,000.00 10/30/2012 Sc17 Coottsdalelns bcs0026129 10/25/2011 10/25/2012 $1,000,000.00 10/31/2011 16 SCOTTSDALE INS CO BCS0023302 10/25/2010 10/25/2011 $1,000,000.00 10/25/2010 15 SCOTTSDALE INS CO BCS0020742 10/25/2009 10/25/2010 $1,000,000.00 10/27/2009 14 FIRST SPECIALTY INS CORP IRG57154 10/25/2008 10/25/2009 $1,000,000.0010/31/2008 13 CTOEADFASTINS SC03557421 08 10/25/2006 10/25/2008 $1,000,000.00 10/25/2007 ST12 EADFAST INS CO SC03557421 07 10/25/2006 10/25/2007 $1,000,000.00 10/30/2006 httns://fortress.wa.gov/lni/bbin/Print.asnx 06/28/2013 MECHANICAL SPECIFICATIONS ORDINANCES, PERMITS, AND CERTIFICATES ALL WORK UNDER THIS DIVISION OF THE SPECIFICATIONS SHALL BE INSTALLED IN FULL ACCORDANCE WITH ALL LAWS, ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AUTHORITIES (LOCAL, STATE, AND FEDERAL) HAVING JURISDICTION WHICH IN ANY WAY WILL AFFECT THIS WORK. THIS CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS AND CERTIFICATES OF INSPECTION REQUIRED BY THE FOREGOING GOVENMENTAL AUTHORITIES. ALL WORK SHALL BE INtTALLED IN FULL ACCORDANCE WITH REGULATIONS OF THE UNDERWRITERS HAVING JURISDICTION.;` VISIT JOB SITE VISIT JOB SITE AND BE FAMILIAR WITH LANDLORD'S REQUIREMENTS. NO ALLOWANCE WILL BE MADE FOR EXTRAS DUE TO CONTRACTOR'S FAILURE TO VISIT THE JOB SITE AND/OR FAILURE TO PREDETERMINE ALL CONDITIONS IMPOSED BY THE LANDLORD OR OTHER AUTHORITIES. GUARANTEE ALL LABOR AND MATERIAL FURNISHED UNDER THIS CONTRACT WILL BE GUARANTEED: FOR A PERIOD OF ONE YEAR FROM DATE OF FINAL ACCEPTANCE BY THE TENANT. DURING THIS TIME, THIS. CONTRACTOR SHALL REPAIR ALL LEAKS AND CORRECT ALL DISCREPANCIES WITH CODES OR THE SPECIFICATIONS AT HIS OWN EXPENSE. DUCTWORK ALL NEW AIR SUPPLY DUCTS SHALL BE MADE OF GALVANIZED SHEET METAL WRAPPED WITH 2" OF INSULATION. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF PAPYRUS'S REPRESENTATIVE. ALL DUCTS WILL BE MADE AIR -TIGHT WITH THE USE OF APPROVED DUCT JOINTS, CAULKING, AND SHEET METAL SCREWS. ALL DUCT -TAPE OR SIMILAR MATERIALS WILL BE REJECTED BY THE TENANT SPACE. INSTALL FIRE DAMPERS WHERE SHOWN AND/OR WHERE REQUIRED BY LAW. 'NO GLASS FIBER OR SIMILAR MATERIALS WELL BE ACCEPTED AS A SUBSTITUTE FOR SHEET METAL DUCTWORK. FLEXIBLE, INSULATED, ROUND DUCT WILL BE PERMITTED FOR FINAL CONNECTIONS TO DIFFUSERS AND OUTLETS PROVIDED THAT, IN NO CASE, SHALL THIS FLEXIBLE DUCT EXCEED 5'-0 IN LENGTH. CONNECTIONS BETWEEN DIFFUSERS AND OUTLETS, AND BETWEEN FLEXIBLE DUCT AND SHEET METAL DUCTS, SHALL BE MADE WITH HOSE CLAMPS OR COLLARS SECURED WITH SHEET • METAL SCREWS. SHORT RADIUS BENDS WILL BE MADE WITH ADJUSTABLE SHEET METAL ELBOWS. DO NOT ATTEMPT SHORT RADIUS BENDS USING FLEXIBLE DUCT. ALL DUCTWORK THROUGH WALLS SHALL BE FIRE DAMPERED IF REQUIRED BY LOCAL CODE. CHILLED WATER COIL/FAN COIL UNIT (EXISTING EQUIPMENT TO BE REFURBISHED AND REUSED) TRANE MODEL #LPCA-A06, 1850 CFM AT .5" EXTERNAL S.P. CONDENSATE LINE TIED TO WASTE SYSTEM. NOTE: CONTRACTOR SHALL PERFORM THE FOLLOWING WORK AND SHALL WARRANT THIS WORK FOR ONE YEAR FROM THE DATE OF ACCEPTANCE BY PAPYRUS'S REPRESENTATIVE. HVAC CONTRACTOR IS RESPONSIBLE FOR ALL STARTERS AND POWER WIRING FOR ALL HVAC EQUIPMENT. EXISTING EQUIPMENT TO BE RECONDITIONED AND REUSED. BRING EQUIPMENT UP TO PROPER , MANUFACTURERS OPERATING SPECIFICATIONS. INSPECT EQUIPMENT AND ADVISE TENANTS REPRESENTATIVE IF ANY MAJOR COMPONENT IS IN NEED OF REPLACEMENT OR REPAIR AT TIME OF BID. THOROUGHLY CLEAN COIL - REPLACE FILTERS WEEKLY DURING CONSTRUCTION, REPLACE BELTS, INSPECT AND LUBRICATE BEARINGS, REPAIR LEAKS AND CHARGE REFRIGERANT, ADJUST AND/OR REPAIR DAMPER LINKAGE TO PROPER OPERATION, AND VERIFY PROPER CONTROL OPERATION. INSPECT DRAIN PAN AND REPLACE OR REPAIR HEATING ELEMENT AS REQUIRED. INSPECT DRAIN PAN REPLACE CONDENSATE LINE WITH NEW 1 1/2" LINE. INSULATION SUPPLY DUCTWORK CONCEALED ABOVE CEILING SHALL HAVE 2" FIBERGLASS `OWEN-CORNING" DUAL TEMP TYPE 100 WITH REINFORCED ALUMINUM FOIL FACING, APPLIED WITH ADHESIVE AND STRAPPED 8' - 0" ON CENTERS WITH STICK CLIPS. EXHAUST FAN EXHAUST FAN WILL BE FURNISHED AND INSTALLED (WHERE SHOWN) BY THE HVAC CONTRACTOR. THIS CONTRACTOR WILL PROVIDE AND INSTALL ALL DUCTS, DAMPERS, FIRE- DAMPERS, BACK -DRAFT DAMPERS, GIRLLES, ETC. AS SHOWN AND/OR REQUIRED. QTY 1 TYPE DESCRIPTION REMARKS BROAN #676 115V/1 PHASE W/T1ME DELAY SWITCH -110 CFM DUCT HEATER DUCT HEATER IN MAIN SUPPLY DUCT - 8KW 1STAGE 208V. INSTALL SAIL SWITCH SO THAT HEATER WILL NOT FUNCTION IF AIR IS NOT FLOWING OVER COIL. VERIFY PROPER OPERATION OF EXISTING, REPLACE IF REQUIRED AS NOTED WITH BRASCH OR ELECTRO DUCT OR APPROVED EQUAL AIR DISTRIBUTION NOTE: ALL DIFFUSERS AND GRILLES TO HAVE FIRE DAMPERS IN NECK, IF REQUIRED BY CODE. CEILING OUTLETS, REGISTERS FAND GRILLES SHALL BE MADE BY TITUS COMPANY OF SIZE AND TYPE SHOWN ON THE DRAWINGS AND ACCORDING TO THE FOLLOWING SCHEDULE WITH BAKED, OFF-WHITE ENAMEL FINISH, UNLESS NOTED. EACH OUTLET SHALL BE COMPLETE WITH OPPOSED BLADE INTEGRAL DAMPER. REFER TO DIAGRAM FOR APPROVED EQUAL. ALL AIR DIFFUSERS SHALL MATCH EXISTING. RETURN AIR GRILLES SHALL BE 1 / 2 X 1 / 2 X 1 / 2 METAL EGG CRATE. VERIFY FRAMING REQUIREMENTS FOR DRYWALL OR GRID CEILING INSTALLATION. 10. AIR BALANCE WHEN THE AIR DISTRIBUTION SYSTEM IS 100% COMPLETE, ENTIRE SYSTEM MUST BE BALANCED TO THE AIR QUANTITIES AS INDICATED ON THE PLANS, IN ACCORDANCE WITH THE AABC OR NEBB SPECIFICATIONS. REPORTS MUST BE SUBMITTED (4 COPIES) FOR EACH SYSTEM FOR APPROVAL TO THE TENANT AND ARCHITECT. COPY OF THE REPORT MUST ALSO BE SUBMITTED TO MALL LANDLORD. THE BALANCING COMPANY SHALL BE AN INDEPENDENT COMPANY AFFILIATED WITH THE AMERICAN AIR BALANCING COUNCIL. 11. TEMPERATURE CONTROL REPAIR OR REPLACE IF REQUIRED HEATING/COOLING THERMOSTAT (AUTO -CHANGEOVER) WITH SUB -BASE CONTROLS FOR HEAT -COOL MODE AND FAN SELECTOR SWITCH AND IS TO BE LOCATED AS SHOWN 48" A.F.F. THERMOSTAT TO BE: PROGRAMMABLE IS TO BE COMPATIBLE WITH LANDLORD'S SYSTEM. VERIFY WITH MALL REPRESENTATIVE. 12. DRAWINGS THIS CONTRACTOR SHALL SUBMIT 4 COPIES OF RECORD DRAWINGS SHOWING EXACT FINAL LOCATIONS OF THE UNIT, DUCTS, DIFFUSERS, ETC. FOR FUTURE REFERENCE. E PRATE. PERMIT REQUIRED FOR: ID Mechanical Electrical Plumbing Gas Piping SPIN -ON BELLN OSE FITTING BRANCH DUCT W/ EXTERNAL INSULATION i RIGID ROUND DUCT MAIN DUCT BRANCH 4" RIGID DUCT EXTENSION ATTACHED TO DIFFUSER NECK MANUAL VOLUME DIFFUSER OPTION #1 TYPICAL DIFFUSER/DUCT CONNECTION DAMPER City of Tukwila 11,0/1 AIVISION FLEXIBLE DUCT MAX. 5'-0" LONG ONE DRAW BAND FOR INNER LINER AND ONE DRAW BAND FOR OUTSIDE VAPOR BARRIER TYPICAL EACH FLEX -DUCT CONNECTION SCALE: NO SCALE CEILING 7 TOILET ROOM ft4�-1 �'� (AS FIELD VERIFIED PRIOR TO LANDLORD'S STOREFRONT WORK). 64'-10" (AS FIELD VERIFIED WORK). 12'-4 3/8" 23'-8 7/8" 23'-8 3/8" 5'-O 1/4" 7 - 11'-5 1/8" STOCK ROOM 4 7/8" yy 52'-4 7/5" ADJACENT TENANT J♦• ►!" • ?�•�. •i"•♦ • ♦•1!i" ...'..'�► !moi f�♦? �♦i• 4�i iiiw•Qi• ♦♦ • iti!!Iwp!a•i!i!i!♦���T�l iO♦♦!a!iA?•Q♦•i!w•�TQ!ii!�le6 i!i�►!i!1•i. Iry ♦�GSi7•:+- �••iiA•i! orare•�a. •�i. ��i!i♦!i�!i! �1I �!Gs!il�iTw•iT !ltili!i�i!Q A!���!���Ti•+!i••+!i•OJ!•!!�i►0i�.1!♦A♦!!wO!�•!�•�•i�iisi!i•Oiii • i ►:� • 'B' 8"0 200 % 1 1 AHU 1 1 0 'A' 10"0 350 0 0 0 EL o 0 350 O 0 SALES AREA ♦.� 7'56 • Oi•si4•i!��• ..10."; O elinitit•frire WSW' ti 41" VT:Ar V ' 3'50 „0 0 EL 0 1 'A'110n0 350 --- PM - MI - MIMN - MI - - MI - ...i....4.1 1•1•72e4C•14V4Weee•r+v ;Or "NW ►1�y♦S►♦i!i�i���♦!�!� . ••:i♦ ♦+. HVAC PLAN ACCU 1 6'-5 3/4" SCALE: 1/4" = 1'-0" 11"1714. ........................................ 14•14..•... 1.1 1414 1414 1 �v♦��i ?Cel -i +i.♦��ie�v y1•. D_-:cc♦.i♦♦! v% ♦iii z° t• w ADJACENT TENANT z 1414_.. `+d�• 0 _ CODE COM LtA CE APPR4VED JUN 2 0 2013 City of T iia BUILDING 1 ISION lc -V. 421 C c Cjj 4J \ O 0 10 FLOOR STOP/BUMBER (TYP OF 2) 1i r STRIKE / HOLD OPEN (TYP OF 2) PIVOT POINT: (TYP OF 2) FILE CO $rmltNo. M P -71C) Y �• x x w appmval is sublc,t to errors i and omissions. Apprdval of construction documents does not authorize the violation of any adopted code or,ordinance. Receipt of approved Field Copy and conditions is acknowledged: BY ddiw Date a 1- [3 qty Of lblkwtta BUILDING DIVISION MALL CONCOURSE TYPICAL AND LANDLORD DETAILS IT IS THE RESPONSIBILITY OF THE _CONTRACTOR PERFORMING THE MECHANICAL WORK TO FAMILIARIZE HIMSELF WITH ALL EXISTING FIELD CONDITIONS AND INSTALLATION DETAILS AS SHOWN ON SHEET #CM, AS WELL AS ANY/ALL APPLICABLE LANDLORD CRITERIA OR DETAILS RELEVANT TO COORDINATE THE INSTALLATION OF THE SYSTEM. NOTHING ON THIS SHEET NOR ANYWHERE IN THIS SET OF DRAWINGS SHALL RELIEVE THE CONTRACTOR OF THEIR RESPONSIBILITY TO VERIFY ALL EXISTING CONDITIONS, NOR TO CONFIRM AND COMPLY WITH REQUIREMENTS OF THE LANDLORD AND THE LOCAL AUTHORITY HAVING JURISDICTION. ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH CODES IN EFFECT AND BEST INDUSTRY PRACTICES. ..111.1. REVISIONS No changes shall be made tootscope of work without prior approval of Tukwila Building Division. { NOTE: Revisions will require a new plan submittal 1 card may include additional plan review tees. - 1.. KEYED NOTES REFURBISH EXISTING SPLIT SYSTEM. (ROOF TOP CONDENSER WITH AIR HANDLING UNIT & ELECTRIC DUCT HEATER WITHIN SPACE)SEE MECHANICAL NOTES THIS SHEET. CONFIRM EXACT LOCATIONS ON SITE. PROVIDE LL COMPONENTS NECESSARY FOR A FULLY FUNCTIONAL SYSTEM THAT MEETS ALL CURRENT L.L. AND CODE REQUIREMENTS. ANY MODIFICATIONS TO DUCTWORK DUE TO RELOCATION TO BE INCLUDED IN BID PRICE. CONFIRM EXISTING CONDITIONS ARE AS FOLLOWS. IF NOT, PROVIDE NEW: DUCT 22 MOUNTED SMOKE DETECTOR IN RETURN AIR DUCT UPSTREAM OF OUTSIDE AIR CONNECTION. WIRE AND LOCATE PER LANDLORD'S SPECIFICATIONS AND DETAILS. C3 PROVIDE FLEX -DUCT TO DIFFUSER NECKS. TYPICAL AT ALL DIFFUSER CONNECTIONS. SEE DETAIL 2/M1 ON THIS SHEET. FLEX -DUCT SHALL BE 5'-0" MAX LENGTH. REUSE/RELOCATE EXISTING THERMOSTAT TO LOCATION SHOWN. MOUNT - 48" A.F.F. TO THE TOP OF THERMOSTAT. APPROXIMATE LOCATION OF EXISTING' OUTSIDE AIR INTAKE REPLACE EXISTING TOILET ROOM EXHAUST FAN WITH NEW AS INDICATED THIS SHEET. PROVIDE NEW LABEL AT ROOF TOP EQUIPMENT WITH TENANT NAME AND UNIT NUMBER. REMOVE PREVIOUS TENANT LABELING. EXISTING MAIN SUPPLY AIR DUCT TO BE REUSED. REPAIR ANY AIR LEAKS. REFURBISH TO LIKE -NEW CONDITION. VERIFY THAT MAIN SUPPLY AIR DUCT WILL ACCOMMODATE NEW 10" ROUND DUCTS AND AIR CFM'S SHOWN. ADVISE ARCHITECT IMMEDIATELY WITH ANY DISCREPANCIES. HVAC SYMBOL LEGEND SUPPLY' AIR DUCTWORK EXISTING DUCTWORK TO BE REUSED AS MUCH AS POSSIBLE SUPPLY AIR TERMINAL RETURN/EXHAUST/TRANSFER KEY NOTE THERMOSTAT SMOKE DETECTOR II►II VIII�IIII uul O SD 'A'18"0 200 (4) EXHAUST FAN VOLUME DAMPER 'A'=TYPE 8"0=NECKSIZE 200=CFM (4)=QUANTITY 0 r RECTANGULAR DUCT MAIN DUCT BRANCH MANUAL VOLUME DAMPER RIGID DUCT - 4 RIGID DUCT --� EXTENSION ATTACHE TO DIFFUSER NECK BOTTOM OR SIDE CONNECTION ONE DRAW BAND /FOR INNER LINER AND ONE DRAW BAND FOR OUTSIDE VAPOR BARRIER - TYPICAL EACH FLEX -DUCT CONNECTION FLEXIBLE DUCT MAX. 5'-0" LONG DIFFUSER OPTIO\ #2 CEILING H.V.A.C. CALCULATIONS SUMMER SPACE 76 F ©50% R.H. OUTSIDE 84 F db/N 68 F wb HEATING SPACE 78 F OUTSIDE 21 F ROOF "U" = 0.00 CLTD = 68 HEAT LOSS SENSIBLE HEAT GAIN LATENT HEAT GAIN ITEM QUANTITY FACTOR BTUH FACTOR BTUH FACTOR BTUH 1. ROOF AREA G.L.A. 1297 SOS FT 4.28 5551 5.71 7406 METALAIRE METALAIRE 2. CORRIDOR WALL 390 SQ FT 4.76 1856 252 983 NOTES 3. OUTSIDE WALL 0 SQ FT 17.34 0 * 0 4. LIGHTING CONNECTION 2.06 3413 7031 5. PEOPLE 24 250 6000 200 4800 6. APPLIANCES - 0 0 0 0 7. OUTSIDE AIR GLA X .2 CFM/SQ FT = 259 55.08 14266 864 2238 680 1761 8. FAN MOTORS 1/2 HP 2545 1273 TOTALS 21673 24931 6561 TOTAL COOLING = (SENSIBLE + LATENT) = 31492 BTU CFM: SENSIBLE BTUH = 1154 CFM 1.06 x 20° LT REMARKS: REUSE/REFURBISH EXISTING SPLIT SYSTEM WALL FACTOR OUTSIDE WALLS NORTH = 3.40 EAST = 10.88 SOUTH = 5.44 WEST = 3.74 DIFFUSER, GRILLE, REGISTER SCHEDULE TYPE'A' 'B' '' ITEM SUPPLY SUPPLY RETURN DESCRIPTION LAY -IN LAY -IN LAY -IN MANUFACTURER METALAIRE METALAIRE METALAIRE MODEL NUMBER 5000-1 3000 D-2 RH NOTES 1,2,3,4 1,2,3,4 1,3 NOTES 1. COLOR SHALL BE WHITE ENAMEL FINISH. 2. ALL UNITS TO BE CONSTRUCTED OF ALUMINUM. 3. DIFFUSERS AMD REGISTERS SHALL HAVE INTEGRAL BUTTERFLY DAMPERS 4. ALL CEILING DIFFUSERS ARE 4 -WAY THROW UNLESS INDICATED OTHERWISE ON PLAN. GENERAL NOTES 1. CONTRACTOR SHALL DESIGN AND HYDRAULICALLY CALCULATE THE NEW AND RENOVATION OF EXISTING SPRINKLER PIPING SYSTEMS, INCLUDING LOCATION OF ALL VALVES, DEVICES, AND SPRINKLER HEADS. DESIGN SPRINKLER SYSTEM PIPING BASED ON HAZARD RATING AS OF THE MOST STRINGENT OF THE REGULATING AGENCIES RESPONSIBLE FOR THIS FACILITY, INCLUDING THE OWNER'S INSURANCE COMPANY REQUIREMENTS AND THE GOVERNING AUTHORITIES, FM OR WARNOCK HERSEY AS DETERMINED BY LOCAL REQUIREMENTS. PERFORM WORK IN ACCORDANCE WITH NFPA 13, 2. PROVIDE SEMI -RECESSED SPRINKLER HEADS IN AREAS WITH LAY -IN CEILINGS. PROVIDE CONCEALED SPRINKLER HEADS IN SALES AREA DRYWALL CEILING. 3. REFER TO SPECIFICATIONS SHEETS FOR ADDITIONAL REQUIREMENTS AND INFORMATION 4. AIR BALANCE REPORT SHALL BE SUBMITTED THE BUILDING DEPARTMENT PRIOR TO FINAL INSPECTION, ALONG WITH TENANT, ENGINEER AND LANDLORD. 5. G.C. SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER (MIN. SIZE 2A:20BC) WHEREVER ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST ONE HOUR AFTER THE COMPLETION OF ANY WELDING. THIS SHALL BE COORDINATED THROUGH THE LOCAL FIRE DEPARTMENT. 6. HVAC CONTRACTOR TO VERIFY LOCATION OF EXISTING HVAC EQUIPMENT AND DUCTWORK. 7. HVAC CONTRACTOR TO SUBMIT DRAWINGS FOR APPROVAL SHOWING ANY DEVIATION TO THE DIAGRAMMATIC SCHEME AS SHOWN HEREIN. 8. DUCT SIZES SHOWN ARE MINIMUM CLEAR SIZES TO ALLOW C.F.M.'S AS SHOWN. 9. DIMENSIONS LOCATING DIFFUSERS ARE PREDICATED BY THE LOCATION OF THE LIGHT FIXTURES AS SHOWN ON SHEET #E2. 10. E.C. TO COORDINATE WITH THE H.V.A.C. CONTRACTOR FOR THE LOCATION AND LIGHTS OF DIFFUSERS RECEIVED CITY OF TUKWIL JUN 042013 PERMIT CENTER t'W5tOI A 2800 EMU) U) 1 VI U C©LEdELi L 9 ONDO 41111 �QG�B 216.781.0186 O co 4) .1 co r - L I,. Mia 4' C CoQ a Q 0 _ CO CO: -0 T a) DRAWN BY: JR CHECKED BY: JMR DATE: 05/29/13 PROJECT NO: 5873 HVAC PLAN M1