Loading...
HomeMy WebLinkAboutPermit M13-103 - LYNCH RESIDENCE - ALTERATIONLYNCH RESIDENCE 10710 49 AV S M13-103 City ofiI'ukwila 1 Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 5476800132 Address: 10710 49 AV S TIIKW Project Name: LYNCH RESIDENCE Permit Number: M13-103 Issue Date: 06/21/2013 Permit Expires On: 12/18/2013 Owner: Name: LYNCH MARTHA+JAMES Address: 10710 49TH AVE S , TUKWILA WA 98178 Contact Person: Name: SHARYN PARKER Address: 7277 PERIMETER RD S , SEATTLE WA 98108 Email: SHARYN.PARKER@KINGCOUNTY.GOV Contractor: Name: BLACK'S CARPENTRY INC Address: 14235 MAPLE VALLEY HY , RENTON WA 98058 Contractor License No: BLACKCI915RG Phone: 206 296-7437 Phone: 206 713-8920 Expiration Date: 12/07/2013 DESCRIPTION OF WORK: PROVIDE VENTILATION IAW PROGRAM REQUIREMENTS, EITHER FURNACE DAMPER OR BLENDING AIR UNIT AND SEPARATE DUCTING Value of Mechanical: $1,754.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and e governing this work will be complied n 'th, Fees Collected: $209.63 International Mechanical Code Edition: 2009 Date: (1PlZali2) this permit and know the same to be true and correct. All provisions of law and ordinances ether specified herein or not. The granting of this permit does not pres - to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Date: 4/2/ /3 This permit shall become null and void if th'work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. •11.19 41,1 o.:..a...l. r 01 OAl PERMIT CONDITIONS Permit No. M13-103 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-103 Printed: 06-21-2013 CITY OF TUKWILO Community Development Department Public Works Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 /2t/p://rpt°tr. ci. tr�lnriln. t n. tis •Mechamcal Perrri't No, Plumbing/Gas Permit 1:•_ �.. Kms, Public Works.Permit No.. =,; 5 Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **Please Print** SITE LOCATION Site Address: 10710 49th Ave. S. Tenant Name: Martha and James Lynch King Co Assessor's Tax No.: 5476800132 Property Owners Name: Martha and James Lynch Mailing Address: 10710 49th Ave. S. Suite Number: Floor: New Tenant: 0 Yes ..No Tukwila WA 98178 City CONTACT PERSON who do we contact when your permit is ready to be issued Name: Sharyn Parker, Program Manager Mailing Address: 7277 Perimeter Road South State Zip Day Telephone: (206) 296-7437 Seattle WA 98108 E -Mail Address: Sharyn.Parker@kingcounty.gov City State Fax Number: (206) 269-7315 Zip GENERAL CONTRACT � � -. OR INFORMATION — (Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)j- Company )j- Company Name: not yet awarded Mailing Address: Contact Person: E -Mail Address: Contractor Registration Number: City Day Telephone: Fax Number: State Zip Expiration Date: ARCHITECT OF RECORD -' All plans must be wet.stamped by Architect of Record Company Name: SM Stemper Architects, PLLC Mailing Address: 4000 Delridge Way SW, Suite 200 Seattle WA 98106 Contact Person: Jesse Holgate or Timothy Fenlason E -Mail Address: jesse@smstemper.com/tenlason@jonespayne.cce City State Day Telephone: (206) 624-2777 Fax Number: (206) 624-2973 Zip ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record Company Name: Mailing Address: Contact Person: E -Mail Address: H'Wpplications\Forms-Applications On Line\2009 Applications\I-2009 - Permit Application.doc Revised' 1-2009 bh City Day Telephone: Fax Number: State Zip Page 1 of 6 BUILDING PERMIT INFO ION - 206-43.1-3670. Valuation of Project (contractor's bid price): $ 32,054 Existing Building Valuation: $ Scope of Work (please provide detailed information): This project has several components that involve upgrades of existing systems and does not require any physical changes to the building footprints and structure, including: Sound Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.) Will there be new rack storage? ❑ Yes ®.. No If yes, a separate permit and plan submittal will be required. Provide All Building Areas in Square Footage Below Existing Interior Remodel Addition to Existing Structure New Type of Construction per IBC Type of Occupancy per IBC IS( Floor .. 1,120 2"d Floor -3ra;Floor Floors Basement 1,120 Accessory Structure*." Attached Garage Detached Garage Attached Carport Detached Carport Covered peck Uneovered Deck - PLANNING DIVISION: Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches) *For an Accessory dwelling, provide the following: Lot Area (sq ft): Floor arca of principal dwelling: Floor area of accessory dwelling: *Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence. Number of Parking Stalls Provided: Standard: Compact: Handicap: Will there be a change in use? ❑ Yes m No If "yes", explain: FIRE PROTECTION/HAZARDOUS MATERIALS: ❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify) Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No /f "yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Alaterial Safety Data Sheets. SEPTIC SYSTEM 0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health Department. H:\Applications\Forms-Applications On Line\2009 Applications \I-2009 - Permit Application.doc Revised: 1-2009 bh Page 2 of 6 PERMIT ARFLICATION NOTESAppthcable to all pelrm>pts m this appl►cahoii ' � �`b.aa." ava ;�":{{"�. .. a .'. •.. ♦ �', � . a Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the Permit Center to comply with current fee schedules. Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation. Building, and Mechanical Permit The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). Plumbing Permit The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW TI -1E SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORJZVD TO APPLY FOR THIS PERMIT. BUILDING OWNER OR IZ Signature: ENT: Date: gar -ow 149 (3 Print Name: Tim• y J. FenlSM Stemper Architects, PLLC Day Telephone: (206) 624-2777 Seattle Mailing Address: 4000 Delridge Way SW, Suite 200 WA 98106 City State Zip Date Application Accepted: Date Application Expires: Staff Initials 0(1 0 5 l I �1 oSIIh ( 3 H,Wpplications\Forms-Applications On Line\2009 Applications \I -2009 -Permit Application.doc Revised: 1-2009 bh Page 6 of6 PLUMBING AND GAS PIPINt HERMIT INFORMATION - 206-43_570 PLUMBING AND GAS PIPING CONTRACTOR INFORMATION Company Name: not yet awarded Mailing Address: City State lip Contact Person: Day Telephone: E -Mail Address: Fax Number: Contractor Registration Number: Expiration Date: Valuation of Project (contractor's bid price): $ Scope of Work (please provide detailed information): Building Use (per Int'I Building Code): Occupancy (per lnt'l Building Code): Utility Purveyor: Water: Sew Indicate type of plumbing fixtures and/or gas pipit outlets being installe• .nd the quantity below: Fixture Type: Qty Fixture Type: Qty Fi t re Type: Qty Fixture Type: Qty Bathtub or combination bath/shower Bidet , .thes washer, domestic Dental unit, cuspidor Dishwasher, domestic, with independent drain Drinking fountain or water cooler (per head) Food -waste grinder, commercial Floor Drain Shower, single head trap Lavatory Wash fountain Receptor, indirect waste Sinks Urinals Water Closet Building sewer and each trailer park sewer Rain water system — per drain (inside building) Water heater and/or nt dustrial waste treatment inceptor, including trap an 'ent, except for kitchen type 'ase interceptors Each grease trap (connected to not more than 4 fixtures - <750 gallon capacity) Grease interceptor for commercial kitchen (>750 gallon capacity) Repair or al ation of water pipir and/or water treatme -quipment Repair alteration of drainage vent piping Medical gas piping system serving 1-5 inlets/outlets for a specific gas Each additional medical gas inlets/outlets greater than 5 Bac -' ow protective de ' e other than a ospheric-type vacuum reakers 2 inch (51 mm) diameter or smaller Backflow pro -five device other than atmo gheric-type vacuum breakers ver 2 inch (51 mm) diam er Each lawn sprinkler system on any one meter including backflow protection devices Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections (1-5) Atmospheric -type vacuum breakers not included in lawn sprinkler backflow protections over 5 Gas piping outlets H NApplications\Forms-Applications On-Line'2009 ApplicationsVI-2009 Permit Application doe Revised 1-2009 hh Page 5 of 6 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 5476800132 Address: 10710 49 AV S TUKW Suite No: Applicant: LYNCH RESIDENCE RECEIPT Permit Number: M13-103 Status: PENDING Applied Date: 06/05/2013 Issue Date: Receipt No.: R13-01829 Payment Amount: $209.63 Initials: JEM Payment Date: 06/06/2013 12:31 PM User ID: 1165 Balance: $0.00 Payee: PAMELA KUEHL WITH KING COUNTY (OVER THE PHONE) TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 051115 ACCOUNT ITEM LIST: Description 209.63 Account Code Current Pmts MECHANICAL - RES PLAN CHECK - RES 000.322.102.00.00 167.70 000.345.830 41.93 Total: $209.63 Printed• 06-06-2013 INSPECTION NO. INSPECTION RECORD Retain a copy with permit r PERMIT CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100„Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 Project: Address: ( rN Type o tr spection: Q Af✓A Date^Called: ((nwsof. Special Instructions: Date Wanted: t• Le �o — f _3' p.m. Requester: 3— —” ED/Approved per applicable codes. Corrections required prior to approval. COMMENTS: r� rtjLk 1 r (A WR InspAtor: t GJ i Date f r 13 REINSPECTION FEE REQUIRED. •PrioP.to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule; reinspection. AiVEFt(IO COORD CON � PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-103 DATE: 06/05/13 PROJECT NAME: LYNCH RESIDENCE SITE ADDRESS: 10710 49 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued. DEPARTMENTS: r� j Ar ._(9-{ Building Division Fire Prevention 1 Public Works ❑ Structural ❑ Planning Division Permit Coordinator DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 06/06/13 Not Applicable ❑ Comments: Permit Center. Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/04/13 Approved ❑ Approved with Conditions] Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Pier Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name BLACKS CARPENTRY INCORPORATED UBI No. 602058636 Phone 2067138920 Status Active Address 14235 Maple Valley Highway License No. BLACKCI915RG Suite/Apt. License Type Construction Contractor City Renton Effective Date 12/7/2009 State WA Expiration Date 12/7/2013 Zip 98058 Suspend Date County King Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status BLACKCI004N1 BLACKS CARPENTRY INCORPORATED Construction Contractor General Unused 8/21/2000 9/20/2002 Archived Business Owner Information Name Role Effective Date Expiration Date BLACK, LAWRENCE President 12/07/2009 Amount GREGORY, LELAND WARD Secretary 12/07/2009 77 -NPP -4-11/16/2012 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 1 CBIC SI4617 11/16/2009 Until Cancelled $12,000.00 12/07/2009 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 Nevada Capital 77 -NPP -4-11/16/2012 11/12/2013 $1,000,000.00 11/08/2012 Ins Co 029885 Contractors 1 Bonding & C11514617 11/16/2009 11/16/2012 $1,000,000.00 10/13/2011 Insuranc Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httns://fortress.wa.i;ov/lni/bbip/Print.aspx 06/21/2013 ABBREVIATIONS LEGEND DRAWING INDEX ACM ACU AFC AFF APPROX ARCH ASHRAE BFC BFF BOD BTUH CD CFM CIRC COND CONT COORD CW DEG DIA DIM DN DWG E, EXIST EA ELEV, EL EAT EG ESP EWT EXH EXP FD FLA FPM FT G GA GAL GALV GPM GRD GWB HP HVAC HW HWC HWG HWR HWS IN KW LAT LWG LWT MAX MBH MCA MIN MTG MFG NC NIC NFPA NG NO NTS OA OAT OC OBD PH POC PSI RA REF REQD RG RPM SA SEC SG SHT SM SMC SO SP SPD SPEC SRC TDH TOD TPD TSP TYP V VD VTR W WB W/ WG WAC ASBESTOS CONTAINING MATERIALS AIR CONDITIONING UNIT ABOVE FINISHED CEILING ABOVE FINISHED FLOOR APPROXIMATE ARCHITECT AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS BELOW FINISHED CEILING BELOW FINISHED FLOOR BOTTOM OF DUCT BRITISH THERMAL UNITS PER HOUR CEILING DIFFUSER CUBIC FEET PER MINUTE CIRCULATING CONDENSATE CONTINUATION COORDINATE COLD WATER DEGREE DIAMETER DIMENSION DOWN DRAWING EXISTING EACH, EXHAUST AIR ELEVATION ENTERING AIR TEMPERATURE EXHAUST GRILLE EXTERNAL STATIC PRESSURE ENTERING WATER TEMPERATURE EXHAUST EXPANSION FAHRENHEIT FIRE DAMPER, FLOOR DRAIN FULL LOAD AMPS FEET PER MINUTE FOOT, FEET GAS GAUGE GALLONS GALVANIZED GALLONS PER HOUR GRILLES, REGISTERS, AND DIFFUSERS GYPSUM WALLBOARD HORSEPOWER HEATING, VENTILATION AND AIR CONDITIONING HOT WATER HOT WATER CIRCULATION HIGH WALL GRILLE HOT WATER RETURN HOT WATER SUPPLY INCH KILOWATT, (1000 WATTS) LEAVING AIR TEMPERATURE LOW WALL GRILLE LEAVING WATER TEMPERATURE MAXIMUM 1000 BTU PER HOUR MINIMUM CIRCUIT AMPS MINIMUM MOUNTING MANUFACTURER NORMALLY CLOSED NOT IN CONTRACT NATIONAL FIRE PROTECTION ASSOCIATION NATURAL GAS NORMALLY OPEN NOT TO SCALE OUTSIDE AIR OUTSIDE AIR TEMPERATURE ON CENTER OPPOSED BLADE DAMPER PHASE POINT OF CONNECTION POUNDS PER SQUARE INCH RETURN AIR REFERENCE REQUIRED RETURN GRILLE REVOLUTIONS PER MINUTE SUPPLY AIR SEATTLE ENERGY CODE SUPPLY DIFFUSER SHEET SHEET METAL SEATTLE MECHANICAL CODE SCREENED OPENING STATIC PRESSURE STATIC PRESSURE DROP SPECIFICATIONS SEATTLE RESIDENTIAL CODE TOTAL DYNAMIC HEAD TOP OF DUCT TOTAL PRESSURE DROP TOTAL STATIC PRESSURE TYPICAL VOLT, VENT VOLUME DAMPER VENT THRU ROOF WASTE WET BULB TEMPERATURE WITH WATER GAUGE WASHINGTON ADMINISTRATIVE CODE NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED SYMBOL ABBR OR 0 X/Y V/ A -S 1 DESCRIPTION DETAIL OR SECTION CALLOUT SHEET WHERE SECTION OR DETAIL SHOWN DIRECTION OF CUTTING PLANE SECTION CUT LINE DIRECTION OF FLOW EQUIPMENT ITEM XX LINE, ARCHITECTURAL BACKGROUND LIGHT LINE, EXISTING HEAVY LINE, NEW WORK ROUND DUCT DIAMETER X PLAN OR HORIZONTAL DIMENSION Y ELEVATION OR VERTICAL DIMENSION EXISTING WORK TO BE REMOVED BREAK IN PIPE OR DUCTWORK FLAG NOTE REVISION NOTE AREA CLOUDED CONTAINS CHANGES TO DRAWINGS SUBSEQUENT TO PREVIOUS ISSUE M1.0 LEGEND; SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX M2.0 MECHANICAL PLANS AND DETAILS GENERAL NOTES 1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION. 2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION. 3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS. 4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS. 5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED AIRTIGHT. 6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR. 7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS. 8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE. 9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS, ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT. 10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET. 11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED. 12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR. REVISIONS No changes shall be made to the scope Of work without prior approval of Tukwila Building Division_ MITE: Ruvisions gill require a new plan submittal an'l may include additional plan review fees. .....i SYMBOL SG—X XXX ABBR 4- 1 DN1 + 1 U + Semi' -wAC 5. 14 �a -01-1— O-4 OR \ EQUIP ID# NG Ibl • 0 D'4 DESCRIPTION DIFFUSER, REGISTER OR GRILLE CALL OUT CFM AMOUNT DN DUCT OFFSET DOWN IN FLOW DIRECTION UP DUCT OFFSET UP IN FLOW DIRECTION DUCT WITHOUT INSULATION INSULATED DUCT UNDERGROUND OR ATTIC DUCT W/ INSULATION ALTERNATE DUCT DUCT FLEX CONNECTION VD VOLUME DAMPER RA/EA RETURN AIR OR EXHAUST AIR DUCT RG RETURN AIR GRILLE SA SUPPLY AIR OUTLET, SIDEWALL SUPPLY AIR DUCT RA/EA RETURN AIR OR EXHAUST AIR DUCT SD SA SUPPLY GRILLE OR DIFFUSER OPEN AREA INDICATED ACTIVE ELEMENTS (4 WAY IF HATCH IS NOT SHOWN) LINEAR DIFFUSER CEILING SUPPLY GRILLE CEILING RETURN GRILLE EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE TRANSITION — RECTANGULAR TO ROUND RECTANGULAR ELBOW WITH TURNING VANES SWITCH THERMOSTAT EQUIPMENT LOCATION MOD MOTOR OPERATED DAMPER NG NATURAL GAS PIPE PIPE/DUCT ELBOW DOWN PIPE/DUCT ELBOW UP BALL VALVE APPLIANCE REGULATOR TWO WAY VALVE DIRT LEG CLEARANCE REQUIREMENT MECHANICAL/ELECTRICAL COORDINATION ITEM NO. EQUIPMENT CONTROL EQUIPMENT REMARKS FURNISHED UNDER DIVISION INSTALLED UNDER DIVISION WIRED UNDER DIVISION VOLTS DESCRIPTION VOLTS PH .5" WG 32"Lx12.25"Wx8.5"H 76 120 23 26 23 26 N/A 23 26 N/A BV -1 BLENDING UNIT VENTILATOR 120 1 X 7" 7" X WALL CAP 1, 2, 3,4 X 25 1,2 — SWITCHES (ON, TIMER) 120 1 1, 2, 4 X 25 X 4" 4" X DECO 1 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 5. BASIS OF DESIGN: SHOEMAKER 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE A. OR APPROVED EQUAL. 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 6. PROVIDE WITH AN OPPOSED BLADE DAMPER 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. REMARKS: 1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL) 2 — DISCONNECT SWITCH BLENDING UNIT VENTILATOR MARK CFM EXTERNAL STATIC DIMENSIONS ELECTRICAL COMMENTS WATTS VOLTS PHASE BV -1 195 .5" WG 32"Lx12.25"Wx8.5"H 76 120 1 1, 2, 3 NOTE: 1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER. 2. PROVIDE WITH SPEED CONTROL 3. BASIS OF DESIGN: ALDES AMERICAN A. OR APPROVED EQUAL. GRILLE AND DIFFUSER SCHEDULE MARK CFM STATIC PRESSURE INLET OR NECK SIZE DUCT CONNECTION LOCATION MODEL # REMARKS 3 SG -1 95 <08" WG 7" 7" CEILING ALLGRILLE 1, 2, 4 SG -1 100 <.08" WG 7" 7" CEILING ALLGRILLE 1, 2, 4 OG -1 120 <.08" WG 7" 7" WALL WALL CAP 1, 2, 3,4 RG -1 25 <.08" WG 4" 4" WALL DECO 1, 2, 4 RG -2 25 <.08" WG 4" 4" CEILING DECO 1, 2, 4 REMARKS: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 5. BASIS OF DESIGN: SHOEMAKER 2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE A. OR APPROVED EQUAL. 3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 6. PROVIDE WITH AN OPPOSED BLADE DAMPER 4. BASIS OF DESIGN: ALDES A. OR APPROVED EQUAL. SRC RESIDENCE CODE FLOOR AREA NUMBER OF BEDROOMS CODE REQUIRED VENTILATION VENTILATION PROVIDED NOTES 0810.03.2324 2260 3 120 CFM 120 CFM 1 1. VENTILATION PROVIDED PER THE SEATTLE RESIDENTIAL CODE, SECTION M1508, TABLES M1508.2 AND M1508.3 MINIMUM DUCT INSULATION THICKNESS DUCT LOCATION MIN VALUE NOTES ON ROOF OR ON EXTERIOR OF BUILDING R-8 WITH WEATHERPROOF BARRIER 1,3 ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING R-8 1,2,3 WITHIN CONDITIONED SPADE OR IN HEATED BASEMENTS R-8 1,3 IN CEMENT SLAB OR IN GROUND R-5 1,3 NOTES: 1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING MEDIUM NOT INCLUDING FINISHING MATERIALS. 2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR. 3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS. BV DRAWING NOTES: LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED TO EXTERIOR WINDOW TRIM PAINT. FILE COPY Permit No. 1 3` itim, Pie lmview approval is oto errors and omissions. j':,y . j of construction documents does not authorize of any adopted code or ordinance. Receipt of approved Field Copy and conditions is acknowledged: Byd�'€1' .�..��r Date: 6/2 //,3 BUILDING DIVISION P ARSflj- PERMIT EQUI ED FOR: 0 Mechanical e Electrical I Iumbing cas Piping 9`4j of Tukwila St .,I 1NG DIVISION SWITCH HOURS OF OPERATION SET BV -1 SWITCH TO OPERATE 1 OF EVERY 2 HOURS. R EWED FOR CODE COMPLIANCE APPROVED JUN 13 2013 �L. City of Tukwila BUILDING DIVISION MECHANICAL VENTILATION CALCULATION PER SRC M1508.3 QF = QR / (&EGR X F) QR = (FROM TABLE 1508.2) 60 &EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1 F = FRACTION OF OPERATION 1/2 QF = 60 / (1 X 1/2) = 120 CFM RECEIVED CITY OF TUKWILA JUN 052013 PERMIT CENTER M 13-I o3 EXPIRES: 9/08/2014 ■ S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 624-2777 • FAX (206) 624-2973 THE GREENBUSCH GROUP, INC 1 0W TMIu (206) 376-0569 0810032324 MECHANIC L ENGINEERING NOE 201 SEATRE. WA 96110 (206) 378-0641 FAX F- 0 0 z 0 F" - Q z > z z 0 U z MPROVEMENTS AIP NUMBER 3-53-0058-45 DATE 09/19/2012 ISSUED 100% CD PROJECT ENGINEER DO PROJECT MANAGER DO DRAWN JA, DT LEGENDS, SCHEDULES, ABBREVS., GENERAL NOTES, & DWG INDEX M 1.0 081003.2324 SEE M2 0 TYP ALL CEILING GRILLES FAMILY ROOM OPEN TO FAMILY ROOM 4' SG -1 100 STUDY U 4"0 UP LOWER FLOOR MECHANICAL PLAN SCALE: 1/4" = 1'-0" OUTSIDE AIR DUCT RETURN AIR DUCT HOLD TIGHT TO STRUCTURE SUPPLY AIR DUCT SOFFIT MOTOR ACCESS FILTERS ACCESS NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. VERIFY UNIT ORIENTATION BEFORE INSTALLATION. 3. INSULATE ALL DUCT AS SCHEDULED. BV -1 INSTALLATION DETAIL SCALE: NONE 1- w rn 0 J 0 LAUNDRY BATH BEDROOM 3 SOFFIT, REFER TO ARCH. TYP ALL WALL GRILLES NORTH SHEETMETAL TRANSITION TO WALL CAP NECK SIZE ZE 7"0 UP/DN KITCHEN LIVING ROOM SG -1 95 DINING ROOM TYP 1- w 0 J 0 CHASE, REFER TO ARCH. BEDROOM 1 - 22" x 30" ATTIC ACCESS PANEL 1- w 0 J 0 0 9"0 UP 0 UP "0 UPS DUCT PER PLAN CAULK 2X BLOCKING 2X BLOCKING FOAM BACKER ROD WALL CAP SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS. / WALL CAP DETAIL SCALE: NONE _Q RG -2 25 L BATH SEE RG -1 25 4"0 4"0 UP (E) BEAM BEDROOM 2 SOFFIT, REFER TO ARCH. CHASE, REFER TO ARCH. 4"0 UP/DN MAIN FLOOR MECHANICAL PLAN SCALE: 1/4" = 1'-0" CAULK SHEETMETAL TRANSITION TO GRILLE NECK SIZE DUCT PER PLAN 2X BLOCKING 2X BLOCKING FOAM BACKER ROD WALL GRILLE SLEEVE AND ESCUTCHEON WALL NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. WALL GRILLE DETAIL SCALE: NONE NORTH SHEETMETAL TRANSITION TO DIFFUSER NECK SIZE 2X BLOCKING SLEEVE ANDIL ESCUTCHEON GRILLE L r LL 700 n U 7"0 DN 22" x 30" EXIST. ATTIC ACCESS PANEL " 1 7"0 DN I 9'10 9110 1 L II 4"0 DN—NLL 1111 4"0 DN VV DN L_ TYP 8"0 -�'— 4"0 DN L_ 4"0 DN 120 ATTIC MECHANICAL PLAN DUCT PER PLAN COORDINATE SOFFIT WITH TECHNICAL REPRESENTATIVE FIELD FABRICATE PLENUM BEHIND CEILING GRILLE FOAM BACKER ROD CAULK 2X BLOCKING FLOOR OR CEILING JOIST CEILING NOTES: 1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS. 2. SEE PLANS FOR VOLUME DAMPER LOCATIONS. 3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR. GRILLE DETAIL(\CEILING SCALE: NONE DRAWING NOTES: SEE NORTH REVIEWED FOR CODE COMPLIANCE APPROVED 1JUN132013 City of 'Tukwila BUILDING DIVISION 1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR 3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SRC M1508.6.6. 2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE FOLLOWING: A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR UNIT SYSTEM(S) WITH NEW FILTERS. FLAG NOTES: BV -1 LOCATED IN SOFFIT. DUCTWORK ROUTED PARTIALLY IN SOFFIT AND ATTIC. COORDINATE ELECTRICAL AND MAINTENANCE ACCESS HATCH WITH TECHNICAL REPRESENTATIVE. ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY TECHNICAL SPECIFICATIONS SECTION 260010. AFFIX A LABEL TO THE CONTROLLER THAT READS "WHOLE HOUSE VENTILATION (SEE OPERATING INSTRUCTIONS)" PER SRC M1508.6.4. COORDINATE FINAL SWITCH LOCATION WITH HOMEOWNER. TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION. PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS AND TECHNICAL SPECIFICATIONS. INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM DUCT INSULATION THICKNESS SCHEDULE ON M1.0. SHEET METAL "Y" FITTING WITH VOLUME DAMPERS. M13- l0 3 RECEIVED CITY OF TUKWIL. " JUN 0 5 2" PERMIT CENTS:,'. ■ S.M. STEMPER ARCHITECTS A Professional Limited Liability Company 4000 DELRIDGE WAY SW SUITE 200 • SEATTLE, WA 98106 (206) 824-2777 • FAX (206) 624-2979 THE GREENBUSCH GROUP, INC • • • • • 11111111111))) MJDI0 VIDEO f IE 201 SEATTLE. 0811 i9oo 1MC18R si r SUIS 201 s�i►mz WA 98119 (208) 378-0569 (206) 378-0841 FAX 0810.03.2324 LL 0 0 >" z Lu O 2 F— LLJ Z W w W 0 Z Z � r. LL Z O U <C Z Q Z W 0 w MPROVEMENTS AIP NUMBER 3-53-0058-45 z 0 0 z W f'— Cn DATE 09/19/2012 ISSUED 100% CD PROJECT ENGINEER DO EXPIRES: 9/08/2014 MECHANICAL PLANS AND DETAILS M2.0 0810.03.2324