HomeMy WebLinkAboutPermit M13-103 - LYNCH RESIDENCE - ALTERATIONLYNCH RESIDENCE
10710 49 AV S
M13-103
City ofiI'ukwila
1
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
MECHANICAL PERMIT
Parcel No.: 5476800132
Address: 10710 49 AV S TIIKW
Project Name: LYNCH RESIDENCE
Permit Number: M13-103
Issue Date: 06/21/2013
Permit Expires On: 12/18/2013
Owner:
Name: LYNCH MARTHA+JAMES
Address: 10710 49TH AVE S , TUKWILA WA 98178
Contact Person:
Name: SHARYN PARKER
Address: 7277 PERIMETER RD S , SEATTLE WA 98108
Email: SHARYN.PARKER@KINGCOUNTY.GOV
Contractor:
Name: BLACK'S CARPENTRY INC
Address: 14235 MAPLE VALLEY HY , RENTON WA 98058
Contractor License No: BLACKCI915RG
Phone: 206 296-7437
Phone: 206 713-8920
Expiration Date: 12/07/2013
DESCRIPTION OF WORK:
PROVIDE VENTILATION IAW PROGRAM REQUIREMENTS, EITHER FURNACE DAMPER OR BLENDING
AIR UNIT AND SEPARATE DUCTING
Value of Mechanical: $1,754.00
Type of Fire Protection: UNKNOWN
Electrical Service Provided by:
Permit Center Authorized Signature:
I hereby certify that I have read and e
governing this work will be complied
n
'th,
Fees Collected: $209.63
International Mechanical Code Edition: 2009
Date:
(1PlZali2)
this permit and know the same to be true and correct. All provisions of law and ordinances
ether specified herein or not.
The granting of this permit does not pres - to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Date: 4/2/ /3
This permit shall become null and void if th'work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
•11.19 41,1
o.:..a...l. r 01 OAl
PERMIT CONDITIONS
Permit No. M13-103
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila
Building Department (206-431-3670).
6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M13-103 Printed: 06-21-2013
CITY OF TUKWILO
Community Development Department
Public Works Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
/2t/p://rpt°tr. ci. tr�lnriln. t n. tis
•Mechamcal Perrri't No,
Plumbing/Gas Permit
1:•_ �.. Kms,
Public Works.Permit No.. =,; 5
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**Please Print**
SITE LOCATION
Site Address: 10710 49th Ave. S.
Tenant Name: Martha and James Lynch
King Co Assessor's Tax No.: 5476800132
Property Owners Name: Martha and James Lynch
Mailing Address: 10710 49th Ave. S.
Suite Number: Floor:
New Tenant: 0 Yes ..No
Tukwila
WA
98178
City
CONTACT PERSON who do we contact when your permit is ready to be issued
Name: Sharyn Parker, Program Manager
Mailing Address: 7277 Perimeter Road South
State
Zip
Day Telephone: (206) 296-7437
Seattle WA 98108
E -Mail Address: Sharyn.Parker@kingcounty.gov
City State
Fax Number: (206) 269-7315
Zip
GENERAL CONTRACT � � -.
OR INFORMATION —
(Contractor Information for Mechanical (pg 4) for Plumbing and Gas Piping (pg 5)j-
Company
)j-
Company Name: not yet awarded
Mailing Address:
Contact Person:
E -Mail Address:
Contractor Registration Number:
City
Day Telephone:
Fax Number:
State
Zip
Expiration Date:
ARCHITECT OF RECORD -' All plans must be wet.stamped by Architect of Record
Company Name: SM Stemper Architects, PLLC
Mailing Address: 4000 Delridge Way SW, Suite 200
Seattle
WA 98106
Contact Person: Jesse Holgate or Timothy Fenlason
E -Mail Address: jesse@smstemper.com/tenlason@jonespayne.cce
City State
Day Telephone: (206) 624-2777
Fax Number: (206) 624-2973
Zip
ENGINEER OF RECORD - All plans must be wet stamped by Engineer of Record
Company Name:
Mailing Address:
Contact Person:
E -Mail Address:
H'Wpplications\Forms-Applications On Line\2009 Applications\I-2009 - Permit Application.doc
Revised' 1-2009
bh
City
Day Telephone:
Fax Number:
State
Zip
Page 1 of 6
BUILDING PERMIT INFO ION - 206-43.1-3670.
Valuation of Project (contractor's bid price): $ 32,054 Existing Building Valuation: $
Scope of Work (please provide detailed information): This project has several components that involve upgrades of
existing systems and does not require any physical changes to the building footprints and structure, including: Sound
Insulation Work, Ventilation Work and Upgrade and Miscellaneous Work (windows, doors, insulation and abatement.)
Will there be new rack storage? ❑ Yes
®.. No If yes, a separate permit and plan submittal will be required.
Provide All Building Areas in Square Footage Below
Existing
Interior Remodel
Addition to
Existing
Structure
New
Type of
Construction per
IBC
Type of
Occupancy per
IBC
IS( Floor ..
1,120
2"d Floor
-3ra;Floor
Floors
Basement
1,120
Accessory Structure*."
Attached Garage
Detached Garage
Attached Carport
Detached Carport
Covered peck
Uneovered Deck -
PLANNING DIVISION:
Single family building footprint (area of the foundation of all structures, plus any decks over 18 inches and overhangs greater than 18 inches)
*For an Accessory dwelling, provide the following:
Lot Area (sq ft): Floor arca of principal dwelling:
Floor area of accessory dwelling:
*Provide documentation that shows that the principal owner lives in one of the dwellings as his or her primary residence.
Number of Parking Stalls Provided: Standard: Compact: Handicap:
Will there be a change in use? ❑ Yes m No If "yes", explain:
FIRE PROTECTION/HAZARDOUS MATERIALS:
❑ Sprinklers ❑ Automatic Fire Alarm m None ❑ Other (specify)
Will there be storage or use of flammable, combustible or hazardous materials in the building? 0 Yes No
/f "yes', attach list of materials and storage locations on a separate 8-1/2"x 11 " paper including quantities and Alaterial Safety Data Sheets.
SEPTIC SYSTEM
0 On-site Septic System — For on-site septic system, provide 2 copies of a current septic design approved by King County Health
Department.
H:\Applications\Forms-Applications On Line\2009 Applications \I-2009 - Permit Application.doc
Revised: 1-2009
bh
Page 2 of 6
PERMIT ARFLICATION NOTESAppthcable to all pelrm>pts m this appl►cahoii '
� �`b.aa." ava ;�":{{"�. .. a
.'. •.. ♦ �', � . a
Value of Construction — In all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the Permit Center to comply with current fee schedules.
Expiration of Plan Review — Applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
Building, and Mechanical Permit
The Building Official may grant one or more extensions of time for additional periods not exceeding 90 days each. The extension shall be
requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
Plumbing Permit
The Building Official may grant one extension of time for an additional period not exceeding 180 days. The extension shall be requested
in writing and justifiable cause demonstrated. Section 103.4.3 Uniform Plumbing Code (current edition).
I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW TI -1E SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORJZVD TO APPLY FOR THIS PERMIT.
BUILDING OWNER OR IZ
Signature:
ENT:
Date: gar -ow 149 (3
Print Name: Tim• y J. FenlSM Stemper Architects, PLLC Day Telephone: (206) 624-2777
Seattle
Mailing Address: 4000 Delridge Way SW, Suite 200
WA 98106
City
State
Zip
Date Application Accepted:
Date Application Expires:
Staff Initials
0(1
0 5
l I
�1 oSIIh ( 3
H,Wpplications\Forms-Applications On Line\2009 Applications \I -2009 -Permit Application.doc
Revised: 1-2009
bh
Page 6 of6
PLUMBING AND GAS PIPINt HERMIT INFORMATION - 206-43_570
PLUMBING AND GAS PIPING CONTRACTOR INFORMATION
Company Name: not yet awarded
Mailing Address:
City State lip
Contact Person: Day Telephone:
E -Mail Address: Fax Number:
Contractor Registration Number: Expiration Date:
Valuation of Project (contractor's bid price): $
Scope of Work (please provide detailed information):
Building Use (per Int'I Building Code):
Occupancy (per lnt'l Building Code):
Utility Purveyor: Water: Sew
Indicate type of plumbing fixtures and/or gas pipit outlets being installe• .nd the quantity below:
Fixture Type:
Qty
Fixture Type:
Qty
Fi t re Type:
Qty
Fixture Type:
Qty
Bathtub or combination
bath/shower
Bidet
, .thes washer, domestic
Dental unit, cuspidor
Dishwasher, domestic,
with independent drain
Drinking fountain or
water cooler (per head)
Food -waste grinder,
commercial
Floor Drain
Shower, single head trap
Lavatory
Wash fountain
Receptor, indirect waste
Sinks
Urinals
Water Closet
Building sewer and each
trailer park sewer
Rain water system — per
drain (inside building)
Water heater and/or nt
dustrial waste treatment
inceptor, including trap
an 'ent, except for kitchen
type 'ase interceptors
Each grease trap
(connected to not more
than 4 fixtures - <750
gallon capacity)
Grease interceptor for
commercial kitchen (>750
gallon capacity)
Repair or al ation of
water pipir and/or water
treatme -quipment
Repair alteration of
drainage vent piping
Medical gas piping
system serving 1-5
inlets/outlets for a
specific gas
Each additional medical
gas inlets/outlets greater
than 5
Bac -' ow protective
de ' e other than
a ospheric-type vacuum
reakers 2 inch (51 mm)
diameter or smaller
Backflow pro -five device
other than atmo gheric-type
vacuum breakers ver 2
inch (51 mm) diam er
Each lawn sprinkler
system on any one meter
including backflow
protection devices
Atmospheric -type vacuum
breakers not included in
lawn sprinkler backflow
protections (1-5)
Atmospheric -type
vacuum breakers not
included in lawn
sprinkler backflow
protections over 5
Gas piping outlets
H NApplications\Forms-Applications On-Line'2009 ApplicationsVI-2009 Permit Application doe
Revised 1-2009
hh
Page 5 of 6
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
Parcel No.: 5476800132
Address: 10710 49 AV S TUKW
Suite No:
Applicant: LYNCH RESIDENCE
RECEIPT
Permit Number: M13-103
Status: PENDING
Applied Date: 06/05/2013
Issue Date:
Receipt No.: R13-01829
Payment Amount: $209.63
Initials: JEM Payment Date: 06/06/2013 12:31 PM
User ID: 1165 Balance: $0.00
Payee: PAMELA KUEHL WITH KING COUNTY (OVER THE PHONE)
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 051115
ACCOUNT ITEM LIST:
Description
209.63
Account Code Current Pmts
MECHANICAL - RES
PLAN CHECK - RES
000.322.102.00.00 167.70
000.345.830 41.93
Total: $209.63
Printed• 06-06-2013
INSPECTION NO.
INSPECTION RECORD
Retain a copy with permit
r PERMIT
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100„Tukwila. WA 98188 (206) 431-367
Permit Inspection Request Line (206) 431-2451
Project:
Address: ( rN
Type o tr spection: Q
Af✓A
Date^Called:
((nwsof.
Special Instructions:
Date Wanted: t•
Le �o — f _3' p.m.
Requester:
3— —”
ED/Approved per applicable codes.
Corrections required prior to approval.
COMMENTS:
r� rtjLk 1 r (A WR
InspAtor:
t
GJ i
Date f r 13
REINSPECTION FEE REQUIRED. •PrioP.to next inspection. fee must be
paid at 6300 Southcenter Blvd., Suite 100. Call to schedule; reinspection.
AiVEFt(IO COORD CON
�
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: M13-103 DATE: 06/05/13
PROJECT NAME: LYNCH RESIDENCE
SITE ADDRESS: 10710 49 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued.
DEPARTMENTS: r� j Ar ._(9-{
Building Division Fire Prevention 1
Public Works ❑ Structural ❑
Planning Division
Permit Coordinator
DETERMINATION OF COMPLETENESS: (Tues., Thurs.)
Complete
Incomplete ❑
DUE DATE: 06/06/13
Not Applicable ❑
Comments:
Permit Center. Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg ❑ Fire 0 Ping 0 PW 0 Staff Initials:
TUESITHURS ROUTING:
Please Route Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 07/04/13
Approved ❑ Approved with Conditions] Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Contractors or Tradespeople Pier Friendly Page
General/Specialty Contractor
A business registered as a construction contractor with L&I to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name BLACKS CARPENTRY INCORPORATED UBI No. 602058636
Phone 2067138920 Status Active
Address 14235 Maple Valley Highway License No. BLACKCI915RG
Suite/Apt. License Type Construction Contractor
City Renton Effective Date 12/7/2009
State WA Expiration Date 12/7/2013
Zip 98058 Suspend Date
County King Specialty 1 General
Business Type Corporation Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
BLACKCI004N1
BLACKS CARPENTRY
INCORPORATED
Construction
Contractor
General
Unused
8/21/2000
9/20/2002
Archived
Business Owner Information
Name
Role
Effective Date
Expiration Date
BLACK, LAWRENCE
President
12/07/2009
Amount
GREGORY, LELAND WARD
Secretary
12/07/2009
77 -NPP -4-11/16/2012
Bond Information
Page 1 of 1
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
1
CBIC
SI4617
11/16/2009
Until Cancelled
$12,000.00
12/07/2009
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
2
Nevada Capital
77 -NPP -4-11/16/2012
11/12/2013
$1,000,000.00
11/08/2012
Ins Co
029885
Contractors
1
Bonding &
C11514617
11/16/2009
11/16/2012
$1,000,000.00
10/13/2011
Insuranc
Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period
Warrant Information No unsatisfied warrants on file within prior 6 year period
Infractions/Citations Information No records found for the previous 6 year period
httns://fortress.wa.i;ov/lni/bbip/Print.aspx 06/21/2013
ABBREVIATIONS
LEGEND
DRAWING INDEX
ACM
ACU
AFC
AFF
APPROX
ARCH
ASHRAE
BFC
BFF
BOD
BTUH
CD
CFM
CIRC
COND
CONT
COORD
CW
DEG
DIA
DIM
DN
DWG
E, EXIST
EA
ELEV, EL
EAT
EG
ESP
EWT
EXH
EXP
FD
FLA
FPM
FT
G
GA
GAL
GALV
GPM
GRD
GWB
HP
HVAC
HW
HWC
HWG
HWR
HWS
IN
KW
LAT
LWG
LWT
MAX
MBH
MCA
MIN
MTG
MFG
NC
NIC
NFPA
NG
NO
NTS
OA
OAT
OC
OBD
PH
POC
PSI
RA
REF
REQD
RG
RPM
SA
SEC
SG
SHT
SM
SMC
SO
SP
SPD
SPEC
SRC
TDH
TOD
TPD
TSP
TYP
V
VD
VTR
W
WB
W/
WG
WAC
ASBESTOS CONTAINING MATERIALS
AIR CONDITIONING UNIT
ABOVE FINISHED CEILING
ABOVE FINISHED FLOOR
APPROXIMATE
ARCHITECT
AMERICAN SOCIETY OF HEATING,
REFRIGERATION AND AIR CONDITIONING ENGINEERS
BELOW FINISHED CEILING
BELOW FINISHED FLOOR
BOTTOM OF DUCT
BRITISH THERMAL UNITS PER HOUR
CEILING DIFFUSER
CUBIC FEET PER MINUTE
CIRCULATING
CONDENSATE
CONTINUATION
COORDINATE
COLD WATER
DEGREE
DIAMETER
DIMENSION
DOWN
DRAWING
EXISTING
EACH, EXHAUST AIR
ELEVATION
ENTERING AIR TEMPERATURE
EXHAUST GRILLE
EXTERNAL STATIC PRESSURE
ENTERING WATER TEMPERATURE
EXHAUST
EXPANSION
FAHRENHEIT
FIRE DAMPER, FLOOR DRAIN
FULL LOAD AMPS
FEET PER MINUTE
FOOT, FEET
GAS
GAUGE
GALLONS
GALVANIZED
GALLONS PER HOUR
GRILLES, REGISTERS, AND DIFFUSERS
GYPSUM WALLBOARD
HORSEPOWER
HEATING, VENTILATION AND AIR CONDITIONING
HOT WATER
HOT WATER CIRCULATION
HIGH WALL GRILLE
HOT WATER RETURN
HOT WATER SUPPLY
INCH
KILOWATT, (1000 WATTS)
LEAVING AIR TEMPERATURE
LOW WALL GRILLE
LEAVING WATER TEMPERATURE
MAXIMUM
1000 BTU PER HOUR
MINIMUM CIRCUIT AMPS
MINIMUM
MOUNTING
MANUFACTURER
NORMALLY CLOSED
NOT IN CONTRACT
NATIONAL FIRE PROTECTION ASSOCIATION
NATURAL GAS
NORMALLY OPEN
NOT TO SCALE
OUTSIDE AIR
OUTSIDE AIR TEMPERATURE
ON CENTER
OPPOSED BLADE DAMPER
PHASE
POINT OF CONNECTION
POUNDS PER SQUARE INCH
RETURN AIR
REFERENCE
REQUIRED
RETURN GRILLE
REVOLUTIONS PER MINUTE
SUPPLY AIR
SEATTLE ENERGY CODE
SUPPLY DIFFUSER
SHEET
SHEET METAL
SEATTLE MECHANICAL CODE
SCREENED OPENING
STATIC PRESSURE
STATIC PRESSURE DROP
SPECIFICATIONS
SEATTLE RESIDENTIAL CODE
TOTAL DYNAMIC HEAD
TOP OF DUCT
TOTAL PRESSURE DROP
TOTAL STATIC PRESSURE
TYPICAL
VOLT, VENT
VOLUME DAMPER
VENT THRU ROOF
WASTE
WET BULB TEMPERATURE
WITH
WATER GAUGE
WASHINGTON ADMINISTRATIVE CODE
NOTE: DRAWINGS MAY NOT CONTAIN ALL ABBREVIATIONS LISTED
SYMBOL
ABBR
OR
0
X/Y
V/ A
-S 1
DESCRIPTION
DETAIL OR SECTION CALLOUT
SHEET WHERE SECTION OR DETAIL SHOWN
DIRECTION OF CUTTING PLANE
SECTION CUT LINE
DIRECTION OF FLOW
EQUIPMENT ITEM XX
LINE, ARCHITECTURAL BACKGROUND
LIGHT LINE, EXISTING
HEAVY LINE, NEW WORK
ROUND DUCT DIAMETER
X PLAN OR HORIZONTAL DIMENSION
Y ELEVATION OR VERTICAL DIMENSION
EXISTING WORK TO BE REMOVED
BREAK IN PIPE OR DUCTWORK
FLAG NOTE
REVISION NOTE
AREA CLOUDED CONTAINS
CHANGES TO DRAWINGS
SUBSEQUENT TO PREVIOUS ISSUE
M1.0 LEGEND; SCHEDULES, ABBREVIATIONS, GENERAL NOTES AND DRAWING INDEX
M2.0 MECHANICAL PLANS AND DETAILS
GENERAL NOTES
1. THE MECHANICAL SYSTEM SHALL CONSIST OF ALL WORK SHOWN ON THE DRAWINGS, INCLUDING FLOOR PLANS, DIAGRAMS, DETAILS, ETC., AND ALL WORK AS IDENTIFIED IN THE SPECIFICATIONS. WORK
INCLUDES FURNISHING, INSTALLING SYSTEM, INTEGRATION, TESTING, TRAINING AND WARRANTY OF THE MECHANICAL SYSTEMS AS SHOWN AND SPECIFIED. PROVIDE A COMPLETE AND OPERABLE MECHANICAL
SYSTEM COMPLETE WITH ALL MECHANICAL WORK AS REQUIRED FOR SYSTEM OPERATION.
2. THE DESIGN OF MECHANICAL SYSTEMS HAS BEEN BASED UPON THE EQUIPMENT AS MANUFACTURED BY THE MANUFACTURERS LISTED ON THE EQUIPMENT SCHEDULE. EQUIPMENT NAMED IN THE SPECIFICATIONS
MAY BE SUBSTITUTED PROVIDED THAT THE EQUIPMENT MEETS OR EXCEEDS ALL SCHEDULED AND SPECIFIED CRITERIA, AND HAS THE WRITTEN APPROVAL OF THE TECHNICAL REPRESENTATIVE. COORDINATE
THE INSTALLATION WITH ALL TRADES AND GUARANTEE IN WRITING THAT NO ADDITIONAL COST WILL BE INCURRED DUE TO PRODUCT SUBSTITUTION.
3. CONTRACTOR SHALL FIELD VERIFY ALL BUILDING AND SITE DIMENSIONS BEFORE BEGINNING CONSTRUCTION OR ORDERING EQUIPMENT. DO NOT SCALE FROM PLANS.
4. DIMENSIONS SHOWN FOR DUCTWORK WITH INSULATION SHALL BE NET FREE DIMENSION WITH INSULATION INSTALLED. INSULATION SHALL MEET SEATTLE ENERGY CODE (SEC) CHAPTER 5, 503.9 REQUIREMENTS.
5. DUCTWORK PENETRATIONS THROUGH WALLS, PARTITIONS, CEILINGS AND ROOFING SYSTEMS SHALL BE SEALED AIRTIGHT. DUCTWORK, OR STRUCTURAL COLUMN PENETRATION THROUGH DUCTS SHALL BE SEALED
AIRTIGHT.
6. PROVIDE ALL REQUIRED ELECTRICAL POWER, AND CONTROL INTERFACE AND CONNECTIONS AS REQUIRED FOR SYSTEM OPERATION. COORDINATE REQUIREMENTS WITH THE ELECTRICAL CONTRACTOR.
7. PROVIDE ACCESS PANELS AS REQUIRED TO MAINTAIN EQUIPMENT, ACCESS VALVES AND DAMPER OPERATORS.
8. COORDINATE LOCATION OF THERMOSTATS AND ALL WALL MOUNTED EQUIPMENT, WITH THE TECHNICAL REPRESENTATIVE. LOCATIONS AS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. LOCATE
THERMOSTATS 4'-0" AFF. UNLESS NOTED OTHERWISE.
9. PROVIDE UNIT SUPPORT PER MANUFACTURERS RECOMMENDATIONS. CONTRACTOR SHALL PROVIDE MATERIALS AND SERVICES INCLUDING BUT NOT LIMITED TO, ADDITIONAL STEEL, SUPPORT BRACKETS, HANGERS,
ACCESSORIES, AND STRUCTURAL ENGINEERING AS REQUIRED TO SUPPORT EQUIPMENT.
10. MAINTAIN 10'-0" CLEARANCE BETWEEN OUTSIDE AIR INTAKE AND EXHAUST OUTLET.
11. PROVIDE FRAMING, CUTTING, BLOCKING AND PATCHING AS REQUIRED.
12. MAINTAIN 3'-0" CLEARANCE FROM EXHAUST OUTLET TO OPERABLE WINDOW OR DOOR.
REVISIONS
No changes shall be made to the scope
Of work without prior approval of
Tukwila Building Division_
MITE: Ruvisions gill require a new plan submittal
an'l may include additional plan review fees.
.....i
SYMBOL
SG—X
XXX
ABBR
4- 1 DN1
+ 1 U +
Semi' -wAC
5. 14
�a
-01-1—
O-4
OR \
EQUIP ID#
NG
Ibl
•
0
D'4
DESCRIPTION
DIFFUSER, REGISTER OR GRILLE CALL OUT
CFM AMOUNT
DN DUCT OFFSET DOWN IN
FLOW DIRECTION
UP DUCT OFFSET UP IN
FLOW DIRECTION
DUCT WITHOUT INSULATION
INSULATED DUCT
UNDERGROUND OR ATTIC
DUCT W/ INSULATION
ALTERNATE DUCT
DUCT FLEX CONNECTION
VD VOLUME DAMPER
RA/EA RETURN AIR OR EXHAUST AIR DUCT
RG RETURN AIR GRILLE
SA SUPPLY AIR OUTLET, SIDEWALL
SUPPLY AIR DUCT
RA/EA RETURN AIR OR EXHAUST AIR DUCT
SD
SA
SUPPLY GRILLE OR DIFFUSER
OPEN AREA INDICATED ACTIVE ELEMENTS
(4 WAY IF HATCH IS NOT SHOWN)
LINEAR DIFFUSER
CEILING SUPPLY GRILLE
CEILING RETURN GRILLE
EA EXHAUST AIR DUCT, EXHAUST AIR GRILLE
TRANSITION — RECTANGULAR
TO ROUND
RECTANGULAR ELBOW
WITH TURNING VANES
SWITCH
THERMOSTAT
EQUIPMENT LOCATION
MOD MOTOR OPERATED DAMPER
NG NATURAL GAS PIPE
PIPE/DUCT ELBOW DOWN
PIPE/DUCT ELBOW UP
BALL VALVE
APPLIANCE REGULATOR
TWO WAY VALVE
DIRT LEG
CLEARANCE REQUIREMENT
MECHANICAL/ELECTRICAL COORDINATION
ITEM
NO.
EQUIPMENT
CONTROL EQUIPMENT
REMARKS
FURNISHED
UNDER DIVISION
INSTALLED
UNDER DIVISION
WIRED
UNDER DIVISION
VOLTS
DESCRIPTION
VOLTS
PH
.5" WG
32"Lx12.25"Wx8.5"H
76
120
23
26
23
26
N/A
23
26
N/A
BV -1
BLENDING UNIT VENTILATOR
120
1
X
7"
7"
X
WALL CAP
1, 2, 3,4
X
25
1,2
—
SWITCHES (ON, TIMER)
120
1
1, 2, 4
X
25
X
4"
4"
X
DECO
1
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 5. BASIS OF DESIGN: SHOEMAKER
2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE A. OR APPROVED EQUAL.
3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 6. PROVIDE WITH AN OPPOSED BLADE DAMPER
4. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
REMARKS:
1 — VERIFY QUANTITY FROM PLANS (TYPICAL ALL)
2 — DISCONNECT SWITCH
BLENDING UNIT VENTILATOR
MARK
CFM
EXTERNAL
STATIC
DIMENSIONS
ELECTRICAL
COMMENTS
WATTS
VOLTS
PHASE
BV -1
195
.5" WG
32"Lx12.25"Wx8.5"H
76
120
1
1, 2, 3
NOTE:
1. COORDINATE THE CONSTANT AIRFLOW REGULATORS (CAR'S) WITH THE MANUFACTURER.
2. PROVIDE WITH SPEED CONTROL
3. BASIS OF DESIGN: ALDES AMERICAN
A. OR APPROVED EQUAL.
GRILLE AND DIFFUSER SCHEDULE
MARK
CFM
STATIC
PRESSURE
INLET OR NECK
SIZE
DUCT
CONNECTION
LOCATION
MODEL #
REMARKS
3
SG -1
95
<08" WG
7"
7"
CEILING
ALLGRILLE
1, 2, 4
SG -1
100
<.08" WG
7"
7"
CEILING
ALLGRILLE
1, 2, 4
OG -1
120
<.08" WG
7"
7"
WALL
WALL CAP
1, 2, 3,4
RG -1
25
<.08" WG
4"
4"
WALL
DECO
1, 2, 4
RG -2
25
<.08" WG
4"
4"
CEILING
DECO
1, 2, 4
REMARKS:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS 5. BASIS OF DESIGN: SHOEMAKER
2 PAINT TO BE COORDINATED WITH TECHNICAL REPRESENTATIVE A. OR APPROVED EQUAL.
3. PROVIDE WITH BACKDRAFT DAMPER AND INSECT SCREEN 6. PROVIDE WITH AN OPPOSED BLADE DAMPER
4. BASIS OF DESIGN: ALDES
A. OR APPROVED EQUAL.
SRC
RESIDENCE CODE
FLOOR AREA
NUMBER OF
BEDROOMS
CODE REQUIRED
VENTILATION
VENTILATION
PROVIDED
NOTES
0810.03.2324
2260
3
120 CFM
120 CFM
1
1. VENTILATION PROVIDED PER THE SEATTLE RESIDENTIAL CODE,
SECTION M1508, TABLES M1508.2 AND M1508.3
MINIMUM DUCT INSULATION THICKNESS
DUCT LOCATION
MIN VALUE
NOTES
ON ROOF OR ON EXTERIOR OF BUILDING
R-8 WITH WEATHERPROOF BARRIER
1,3
ATTIC, GARAGE, CRAWL SPACE, IN WALLS, IN FLOOR/CEILING
R-8
1,2,3
WITHIN CONDITIONED SPADE OR IN HEATED BASEMENTS
R-8
1,3
IN CEMENT SLAB OR IN GROUND
R-5
1,3
NOTES:
1. THICKNESS OF INSULATION IS DEFINED AS THE THICKNESS OF THE BASIC INSULATING
MEDIUM NOT INCLUDING FINISHING MATERIALS.
2. INSULATION MAY BE OMITTED ON THAT PORTION OF A DUCT WHICH IS LOCATED WITHIN A WALL OR
FLOOR/CEILING SPACE WHERE BOTH SIDES OF THIS SPACE ARE EXPOSED TO UNCONDITIONED AIR AND
WHERE THIS SPACE IS NOT VENTILATED OR OTHERWISE EXPOSED TO CONDITIONED AIR.
3. REFER TO SEATTLE ENERGY CODE FOR ADDITIONAL REQUIREMENTS.
BV
DRAWING NOTES:
LEAD PAINT IS PRESENT AT THIS RESIDENCE. REFER TO
SECTIONS 011101 AND 028300 FOR REQUIREMENTS RELATED
TO EXTERIOR WINDOW TRIM PAINT.
FILE COPY
Permit No. 1 3` itim,
Pie lmview approval is oto errors and omissions.
j':,y . j of construction documents does not authorize
of any adopted code or ordinance. Receipt
of approved Field Copy and conditions is acknowledged:
Byd�'€1' .�..��r
Date: 6/2 //,3
BUILDING DIVISION
P ARSflj- PERMIT
EQUI ED FOR:
0 Mechanical
e Electrical
I Iumbing
cas Piping
9`4j of Tukwila
St .,I 1NG DIVISION
SWITCH HOURS OF OPERATION
SET BV -1 SWITCH TO OPERATE 1 OF EVERY 2 HOURS.
R EWED FOR
CODE COMPLIANCE
APPROVED
JUN 13 2013
�L.
City of Tukwila
BUILDING DIVISION
MECHANICAL VENTILATION CALCULATION
PER SRC M1508.3
QF = QR / (&EGR X F)
QR = (FROM TABLE 1508.2) 60
&EGR = VENTILATION EFFECTIVENESS (EXCEPTION IF SYSTEM OPERATES 1 OF EVERY 3 HOURS) = 1
F = FRACTION OF OPERATION 1/2
QF = 60 / (1 X 1/2) = 120 CFM
RECEIVED
CITY OF TUKWILA
JUN 052013
PERMIT CENTER
M 13-I o3
EXPIRES: 9/08/2014
■
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 624-2777 • FAX (206) 624-2973
THE GREENBUSCH GROUP, INC
1 0W TMIu
(206) 376-0569
0810032324
MECHANIC L ENGINEERING
NOE 201 SEATRE. WA 96110
(206) 378-0641 FAX
F-
0
0
z
0
F" -
Q
z
>
z
z
0
U
z
MPROVEMENTS
AIP NUMBER
3-53-0058-45
DATE
09/19/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
PROJECT MANAGER
DO
DRAWN
JA, DT
LEGENDS,
SCHEDULES,
ABBREVS.,
GENERAL
NOTES, &
DWG INDEX
M 1.0
081003.2324
SEE M2 0 TYP ALL
CEILING GRILLES
FAMILY
ROOM
OPEN TO
FAMILY ROOM
4'
SG -1
100
STUDY
U
4"0 UP
LOWER FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
OUTSIDE AIR
DUCT
RETURN AIR
DUCT
HOLD TIGHT TO
STRUCTURE
SUPPLY AIR DUCT
SOFFIT
MOTOR ACCESS
FILTERS ACCESS
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. VERIFY UNIT ORIENTATION BEFORE INSTALLATION.
3. INSULATE ALL DUCT AS SCHEDULED.
BV -1 INSTALLATION DETAIL
SCALE: NONE
1-
w
rn
0
J
0
LAUNDRY
BATH
BEDROOM
3
SOFFIT, REFER TO ARCH.
TYP ALL
WALL GRILLES
NORTH
SHEETMETAL
TRANSITION TO WALL
CAP NECK SIZE
ZE
7"0 UP/DN
KITCHEN
LIVING
ROOM
SG -1
95
DINING
ROOM
TYP
1-
w
0
J
0
CHASE, REFER TO ARCH.
BEDROOM
1
- 22" x 30" ATTIC
ACCESS PANEL
1-
w
0
J
0
0
9"0 UP
0 UP
"0 UPS
DUCT PER PLAN
CAULK
2X BLOCKING
2X BLOCKING
FOAM BACKER
ROD
WALL CAP
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. COORDINATE WITH ARCHITECTURAL DETAIL DRAWINGS.
/ WALL CAP DETAIL
SCALE: NONE
_Q
RG -2
25
L
BATH
SEE
RG -1
25
4"0
4"0 UP
(E) BEAM
BEDROOM
2
SOFFIT, REFER TO ARCH.
CHASE, REFER TO ARCH.
4"0 UP/DN
MAIN FLOOR MECHANICAL PLAN
SCALE: 1/4" = 1'-0"
CAULK
SHEETMETAL
TRANSITION TO
GRILLE NECK SIZE
DUCT PER PLAN
2X BLOCKING
2X BLOCKING
FOAM BACKER
ROD
WALL GRILLE
SLEEVE AND
ESCUTCHEON
WALL
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. WALL SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
WALL GRILLE DETAIL
SCALE: NONE
NORTH
SHEETMETAL
TRANSITION TO
DIFFUSER NECK
SIZE
2X BLOCKING
SLEEVE ANDIL
ESCUTCHEON
GRILLE
L
r
LL
700
n
U
7"0 DN
22" x 30" EXIST.
ATTIC ACCESS
PANEL
"
1
7"0 DN
I
9'10
9110
1
L
II
4"0 DN—NLL
1111 4"0 DN
VV
DN
L_
TYP
8"0
-�'— 4"0 DN
L_
4"0 DN
120
ATTIC MECHANICAL PLAN
DUCT PER PLAN
COORDINATE SOFFIT
WITH TECHNICAL
REPRESENTATIVE
FIELD FABRICATE
PLENUM BEHIND
CEILING GRILLE
FOAM BACKER ROD
CAULK
2X BLOCKING
FLOOR OR
CEILING JOIST
CEILING
NOTES:
1. INSTALL PER MANUFACTURER'S WRITTEN INSTRUCTIONS.
2. SEE PLANS FOR VOLUME DAMPER LOCATIONS.
3. CEILING SUPPLY INSTALLATION SHOWN, RETURN SIMILAR.
GRILLE DETAIL(\CEILING
SCALE: NONE
DRAWING NOTES:
SEE
NORTH
REVIEWED FOR
CODE COMPLIANCE
APPROVED
1JUN132013
City of 'Tukwila
BUILDING DIVISION
1. FIELD VERIFY OUTSIDE AIR INLET LOCATION IS AT MINIMUM 10 FEET AWAY OR
3 FEET BELOW ANY HAZARDOUS OR NOXIOUS SOURCE PER SRC M1508.6.6.
2. FILTERS: AFTER EQUIPMENT AND SYSTEM CHECK-OUT WORK HAS BEEN
COMPLETED AND PRIOR TO COMMENCEMENT OF TAB WORK, PERFORM THE
FOLLOWING:
A) REPLACE AIR FILTERS IN THE FURNACE AND/OR BLENDING AIR
UNIT SYSTEM(S) WITH NEW FILTERS.
FLAG NOTES:
BV -1 LOCATED IN SOFFIT. DUCTWORK ROUTED PARTIALLY IN
SOFFIT AND ATTIC. COORDINATE ELECTRICAL AND
MAINTENANCE ACCESS HATCH WITH TECHNICAL
REPRESENTATIVE.
ELECTRICIAN TO PROVIDE PROGRAMMABLE TIMER SWITCH BY
TECHNICAL SPECIFICATIONS SECTION 260010. AFFIX A LABEL
TO THE CONTROLLER THAT READS "WHOLE HOUSE
VENTILATION (SEE OPERATING INSTRUCTIONS)" PER SRC
M1508.6.4. COORDINATE FINAL SWITCH LOCATION WITH
HOMEOWNER.
TRANSITION DUCT TO AIR TERMINAL NECK SIZE IMMEDIATELY
BEFORE MAKING FINAL GRILLE OR DIFFUSER CONNECTION.
PROVIDE CUTTING AND PATCHING AS REQUIRED TO INSTALL
OUTSIDE AIR INLET, REFER TO ARCHITECTURAL DRAWINGS
AND TECHNICAL SPECIFICATIONS.
INSULATE ALL DUCT AS SCHEDULED. REFER TO THE MINIMUM
DUCT INSULATION THICKNESS SCHEDULE ON M1.0.
SHEET METAL "Y" FITTING WITH VOLUME DAMPERS.
M13- l0 3
RECEIVED
CITY OF TUKWIL. "
JUN 0 5 2"
PERMIT CENTS:,'.
■
S.M. STEMPER
ARCHITECTS
A Professional Limited Liability Company
4000 DELRIDGE WAY SW
SUITE 200 • SEATTLE, WA 98106
(206) 824-2777 • FAX (206) 624-2979
THE GREENBUSCH GROUP, INC
• • • • • 11111111111)))
MJDI0 VIDEO f IE 201 SEATTLE.
0811
i9oo 1MC18R si r SUIS 201 s�i►mz WA 98119
(208) 378-0569 (206) 378-0841 FAX
0810.03.2324
LL
0
0
>"
z Lu
O 2
F— LLJ
Z W
w
W 0
Z
Z �
r. LL
Z
O
U <C
Z Q
Z
W
0
w
MPROVEMENTS
AIP NUMBER
3-53-0058-45
z
0
0
z
W
f'—
Cn
DATE
09/19/2012
ISSUED 100% CD
PROJECT ENGINEER
DO
EXPIRES: 9/08/2014
MECHANICAL
PLANS AND
DETAILS
M2.0
0810.03.2324