HomeMy WebLinkAboutPermit M13-110 - CASCADE VIEW ELEMENTARY - ALTERATIONCASCADE VIEW
ELEMENTARY
13601 32 AV S
M13-110
City ofukwila
�J qs
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Inspection Request Line: 206-431-2451
Web site: http://www.TukwilaWA.gov
Parcel No.: 1623049038
Address: 13601 32 AV S TUKW
Project Name: CASCADE VIEW ELEMENTARY
MECHANICAL PERMIT
Permit Number: M13-110
Issue Date: 06/27/2013
Permit Expires On: 12/24/2013
Owner:
Name: TUKWILA SCHOOL DISTRICT
Address: 4640 S 144TH ST , TUKWILA WA 98168
Contact Person:
Name: LARRY MAYOTTE
Address: 5005 3 AV , SEATTLE WA 98134
Email: LARYMA@MCKINSTRY.COM
Contractor:
Name: MCKINSTRY CO LLC
Address: PO BOX 24567 , SEATTLE WA 98124
Contractor License No: MCKINCL942DW
Phone: 206 200-8871
Phone: 206 762-3311
Expiration Date: 03/16/2014
DESCRIPTION OF WORK:
REPLACEMENT OF 1.5 TON (18,000 BTU) COOLING ONLY MINI -SPLIT SYSTEM TO CONDITION
IDF DATA CLOSET. CONDENSING UNIT IS ROOF MOUNTED AND EVAPORATOR IS WALL MOUNTED
IN THE DATA CLOSET.
Value of Mechanical: $6,762.00
Type of Fire Protection: SPR]NKLERS/AFA
Electrical Service Provided by:
Permit Center Authorized Signature:
Fees Collected: $269.31
International Mechanical Code Edition: 2009
Date: dko/ 2K?
I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances
governing this work will be complied with, whether specified herein or not.
The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating
construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the
back of this permit.
Signature:
Date: 6/21/13
Print Name: LAagy `I/tA'/o tiir
This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended
or abandoned for a period of 180 days from the last inspection.
n..:..a..d. nc n-7 nni
PERMIT CONDITIONS
Permit No. M13-110
1: ***BUILDING DEPARTMENT CONDITIONS***
2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the
Building Official.
3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to
start of any construction. These documents shall be maintained and made available until final inspection approval is
granted.
4: All construction shall be done in conformance with the approved plans and the requirements of the International
Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code.
5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building
Department (206-431-3670).
6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of,
any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits
presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila
shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the
Building Official from requiring the correction of errors in the construction documents and other data.
doc: IMC -4/10
M13-110 Printed: 06-27-2013
CITY OF TUKWILA
Community Development Department
Permit Center
6300 Southcenter Blvd., Suite 100
Tukwila, WA 98188
http://www.TukwilaWA.gov
Mechanical Permit No. t?j , t
Project No.
Date Application Accepted: (k)I � I
Date Application Expires: 11
(For office use only)
MECHANICAL PERMIT APPLICATION
Applications and plans must be complete in order to be accepted for plan review.
Applications will not be accepted through the mail or by fax.
**please print**
SITE LOCATION;''
King Co Assessor's Tax No.:
Site Address: 13601 32nd Avenue South Suite Number: Floor:
It0230490 3a
Tenant Name: Cascade View Elementary School
PROPERTY OWNER
Name: Larry Mayotte
Name: Tukwila School District
Address: 5005 3rd Ave
Address: 4640 S 144th Street
City: Seattle State: Wa
City: Tukwila State: Wa
Zip: 98168
CONTACT PERSON — person receiving all project
communication
Name: Larry Mayotte
Address: 5005 3rd Ave
Address: 5005 3rd Ave
Phone: (206) 200-8871 Fax: (253) 272-1714
City: Seattle State: Wa
Zip: 98134
Phone: (206) 200-8871 Fax: (253)
272-1714
Email: larryma@mckinstry.com
New Tenant: ❑ Yes ® ..No
MECHANICAL CONTRACTOR LNFORMATION
Company Name: McKinstry
Address: 5005 3rd Ave
City: Seattle State: Wa Zip: 98134
Phone: (206) 200-8871 Fax: (253) 272-1714
Contr Reg No.:MCKINCL942DW Exp Date: 03/16/2014
Tukwila Business License No.: ',0s — 010i 413
Valuation of project (contractor's bid price): $
Describe the scope of work in detail:
Replacement of 1.5 (18,000 BTU) Ton Cooling only mini -split system to condition IDF Data Closet. Condensing unit is roof
mounted and evaporator is wall mounted in the data closet.
6,762
Use: Residential: New ❑ Replacement ❑
Commercial: New ❑ Replacement m
Fuel Type: Electric
Gas ❑
Other:
H:\Applications\Forms-Applications On Line \2011 ApplicationsN9echanical Permit Application Revised 8-9-11.docx
Revised: August 2011
bh
Page 1 of 2
•
Indicate type of mechanical work being installed and the quantity below:
Unit Type
Qty
Furnace <100k btu
Furnace >100k btu
Floor furnace
Suspended/walUfloor
mounted heater
Appliance vent
Repair or addition to
heat/refrig/cooling
system
1
Air handling unit
<10,000 cfm
Unit Type
Qty
Air handling unit
>10,000 cfm
Evaporator cooler
Ventilation fan
connected to single duct
Ventilation system
Hood and duct
Incinerator — domestic
Incinerator —
comm/industrial
1
Unit Type
Qty
Fire damper
Diffuser
Thermostat
Wood/gas stove
Emergency generator
Other mechanical
equipment
Boiler/Compressor
Qty
0-3 hp/100,000 btu
3-15 hp/500,000 btu
15-30 hp/1,000,000 btu
30-50 hp/1,750,000 btu
50+ hp/1,750,000 btu
PERMIT APPLICATION NOTES -
Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject
to possible revision by the permit center to comply with current fee schedules.
Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation.
The building official may grant one.extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing
and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition).
I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER
PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT.
BUILDING OWNERDR AUTHORIZED AGENT:
Signature:
CA. /
Date: 06/14/2013
Print Name: Larry Mayotte Day Telephone: (206) 200-8871
Mailing Address: 5005 3rd Ave Seattle Wa 98134
City State Zip
H:\Applicaiions\Fotms-Applications On Line 2011 Applications'Mechanical Permit Application Revised 8.9.11.docx
Revised: August 2011
bh
Page 2 of 2
• •
City of Tukwila
Department of Community Development
6300 Southcenter Boulevard, Suite #100
Tukwila, Washington 98188
Phone: 206-431-3670
Fax: 206-431-3665
Web site: http://www.TukwilaWA.gov
Parcel No.: 1623049038
Address: 13601 32 AV S TUKW
Suite No:
Applicant: CASCADE VIEW ELEMENTARY
RECEIPT
Permit Number: M13-110
Status: PENDING
Applied Date: 06/18/2013
Issue Date:
Receipt No.: R13-01903
Payment Amount: $269.31
Initials: JEM Payment Date: 06/18/2013 11:02 AM
User ID: 1165 Balance: $0.00
Payee: LAWRENCE A MAYOTTE
TRANSACTION LIST:
Type Method Descriptio Amount
Payment Credit Crd VISA
Authorization No. 04597C
ACCOUNT ITEM LIST:
Description
269.31
Account Code Current Pmts
MECHANICAL - NONRES
PLAN CHECK - NONRES
000.322.102.00.00 215.45
000.345.830 53.86
Total: $269.31
Drin*n.1• !1R_'IA_')l11Z
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
rnil3-11 0
Project: -
C' FISC A sem. V I f J
Type of Inspection:
,- 11•.i icl L__
Address:
t-3vo t 32_ no <-
Date Called:
Special Instructions:
Date Wanted: n_ n
a.rrl
Requester:
Phone No:
)(T)6, - 2S -S
Li30 S
,Approved: per applicable codes.
COMMENTS:,
Corrections required prior to approval.
Date:
31-. 1�
PECTION ' EE REQUIRE . Prior to next inspection, fee must be
at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection.
INSPECTION NO.
CITY OF TUKWILA BUILDING" DIVISION
• 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
INSPECTION RECORD
stain a copy with permit
1fl/3 //O
PERMIT NO.
41)
Project: !A' ', / �y
e451� 6 b'/f EL E n
Type`of Inspection. � /j� % �^-
61 r / / y �CJ / , y . /et. J
d
Address: .
/-?C0/ 3.2 4v s
Date Called:
Special Instructions:
Date Wanted:'.
/ 0 --/6 --/3 p.m.
Requester:
Phone No:
a) - S —'3O5
f&pproved per applicable codes. El Corrections required prior to approval.
COMMENTS:
ooer •
ge-ef7:450,7( ,72:/vf,Pcr-ri nA1— "./P
PC 7o /11,9(4)411k1) e -7 //
Date
NSPECTION FEEIQUIRED. Pricy to next inspection. fee must be
aid at 6300 Southcente Blvd., Suite 100. Call to schedule reinspection.
INSPECTION RECORD
Retain a copy with permit
INSPECTION NO. PERMIT NO.
CITY OF TUKWILA BUILDING DIVISION
6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670
Permit Inspection Request Line (206) 431-2451
(t°
Project:
0 AQ I VlEU.)
TyRe of Inspection:
0f -M, 2.141-10 NI - ec-r
Address:
t3(oOt 3,, \U S
Date Called:
Special Instructions:
fi-
Date Wanted:
Ct-- J — t 3
m.
p.m.
Requester:
Phone No:
ca.p ta— ;.-55 —i--13 a5
DApproved per applicable codes.
giCorrections required prior to approval.
COMMENTS:
t\SC P/ecpM-hJ '� e 01) c,d nNo mt 1 iiia L
XPi
.1'2i1O E-- I ikiS Peo 1 t O.&) Cd
Rcn
P F 1 lam. t 14-4
G, E - t -c° 04t Y i C >4
5
r I iia C -- 1.1E.to)
Date:
El INSPECTION FEE RQUIRED. Prior
p ;t at 6300 Southcenter Blvd.. Suite 1
o next inspection. fee must be
0. Call to schedule reinspection.
PIA^
of
GASMETER(5200 M8H.2P51 OUTLET)
it
2 WAY FOC
rade approves is subject to errors aconstructiond'omissions.
0 0documents does- npt auor
of any code or ounce. tipt
ro Field Cody and conditions
By ._. I 44,�o•
Date Le/77/i
at y Of 1Ukwiia
II. .
BUILDING DIVISION
SEE Sg9EET C1.2 FOR,CONT.
(PIPIN5 UPSTREAM OF PN 6Y DIV. 2000MY.
tamJew ACP
‘1.1
E4Pi4'-` este''(°
r ` /
1 pig
r \\
Li
SEPARATE. ptrvirr
REQUIRED FOR
Meds.
CEI
['Plum
was
of Tu Iles'
'NG D VlSION-
KEY NOTES
C UNDERGROUND SPRINKLER
PIPING (54IN.3' BURY) FOR FDC
(BY DN. 15000) PROVIDE THRUST
. BLOCKS AT ALL CHANGES
IN DIRECTION.
O6.. UNDERGROUND SPRINKLER
MAIN (61104.3' BURY) BY
DN. 15000. PROVIDE THRUST
BLOCKS AT ALL CHANGE
IN DIRECTION.
GAS LINE UPSTREAM OF METER
BY WAG. CONTRACTOR TO
COORDINATE ROUTING OF
OTHER UTILITIES W/ WAC.
O. EXISTING GAS METER. WNG TO
PROVIDE TEMPORARY CONNECTION
TO THIS METER A5 REOUIREO BY
PHASED CONSTRUCTION. CONTRACTOR
TO COORDINATE THS WORK WITH
THE UTILITY COMPANY.
C UNDERGROUND FIRE
MAN (MIN.3' BURY) BY
04V. 15000. PROVIDE THRUST
BLOCKS AT ALL CHANGE
IN DIRECTION.
OS CW SE(MCE. CONNECT
TO EXISTING DOMESTIC WATER
SERVICE MANAT LOCATION
SHOWN ON SHET77 C1.2.
OEXISTING TRANSFORMER VAULT
CAREFULLY COORDINATE ALL -
011211E5 IN THIS AREA.
OSEE SHEET C1.2 FOR CONNECTION
TO 5S. OR S.D.. SYSTEM.
•
REVIEWED FOR
CODEAPCOPROVEbMPUAND
E
JUN 25 2013
til— V4
City of Tukwila
BUILDING DIVISION
No ctang
-•1
RECEIVED
CITY OF TUKWILA
JUN 182013
PERMIT CENTER
without-pnoc_approval of
\:Vila Building Division
tai, will require a new plan Submittal
1
11.11I111111111i1 i
A 0 C 1.1'1 1 .0 T•
• 1011:Western ensue
Suite No. : 701 '.
Secede. Wo - 98104:
. E.206/340-9519
' RfJBERi F05$ATf ASSOC
001 Saari bmm.'5y.160
5.45401039ni.Mn 0(04
• P 921-1803 F'621-9740 .
•
HARG15 ENGINEERS; INC
• 609 SY.0ttm�n
39.41.Sub 1900
593394. 1
-3376 C 440-4450
Ems,
BAR DESIGN COMPANY
911 IFMn Rema / 062
Sottle, 99104
P 76-0126 i 2 S-012! .
CIA 99nRera.
NN(ANO DENMS
300 ERA P9u Amt
Swat* Wastolgton 99122
.P2929 psF .
hslitects
GEORGE BUNDY,'ori0 ASSOC
1029 NE 894.60 Bed
P 523,96901"r"523-131 '
. .
THE GREENBUSCH GROUP .
919 IE 71.4
Seattle. m 991(3
P.524-0533 241 FF 504-0830
LICCIERWIEN660/LdI11CN.TO
CASCADE r111
ELEISTARDOCt
'13601 324 Henn South ' .
Tubado. Wmhegton 98168
WPR01fD FOR TIE.98101
JOB 049 99175 . .
Ma DATE 3_12-95
CIEOOD MW
SrrE- PLAN
MECHANICAL
COOLING & HEATING
REVIEWED FOR
QDE COMPLIANCE
APPROVED
►JUN 2 5 2013
P -Series Full -line Catalog
Commercial -grade Applications
Smart, Efficient INVERTER -driven Ductless and Ducted Comfort Systems
www.mitsubishipro.com
Take a. Closer Look at the P: Series Commercial Systems
.z
fromM,tsubishi. Electric Coolingand Heating Solutions.
4
Gliameramermweraiim•sttillil'
Explore the Ultimate Value in Today's Commercial HVAC Market.
For over 30 years Mitsubishi Electric has been a
leader in the United States in providing the most
energy-efficient, environmentally friendly HVAC
products for commercial use.
Mitsubishi Electric's advanced technologies include
INVERTER -driven compressor systems which use only
the exact amount of energy needed to cool or heat
an area. This feature means your customers will save
energy—and major costs—while experiencing precise
control over their comfort year-round.
Zone Control plus Personal Control
Split ductless and ducted systems userefrigerant
lines to connect outdoor units toone or more indoor
air handlers. The result of this benefit is that the.,
temperature within any space with an indoor unit
installed can be controlled to provide the perfect
temperature. Along with this capability to provide
precise temperature control for any space, our systems
also offer the unique ability to condition only those
spaces in current use at any given time.
Mitsubishi Electric's systems employ user-friendly,
wireless, wall -mounted, or hand-held controllers
which deliver pinpoint comfort very efficiently. Zone
control coupled with personal control equals all-around
energysavings ;..... ._>...
it°a "i
•
•
i€:,
State of=the.-,art Design and Smarter
'Functionality
When ydii choose Mitsubishi Electric P -Series products
for your commercial grade applications, you're making
an excellent choice that your customers will appreciate
,for its intelligent,function and the true, year-round
•
;eco comfort it delivers. ;
{ 3 is fat : ; jl,
MITSUBISHI ELECTRIC visit www.MitsubishiPro.com
Are Mitsubishi Electric P -Series
Systems Truly Environmentally
Friendly for Commercial Duty?
ENERGY STAR
PARTNER
Count on Mitsubishi Electric to set the standard for
making ecologically responsible systems that minimize
the impact both on the environment and on your
customer's carbon footprint.
The fact that 83% of our components are recyclable is just
the beginning of our commitment. Mitsubishi Electric has
more systems today that are ENERGY STAR certified than
ever before. Local and state government plus utility companies
provide tax credits and rebate opportunities for energy-efficient
systems. Check to see what is available in your area by visiting
www.dsireusa.org.
How many P -Series systems are ENERGY STAR
rated and qualify for the federal tax credit?
9 systems are ENERGY STAR rated
PKA-A30KA, PKA-A36KA, PLA-A30BA, PLA-A36BA, PCA-A30KA,
PCA-A36KA —, PEA-A18AA (x2), PEAD-A30AA, PEAD-A30AA
2 systems qualify for the federal tax credit
PLA-A36BA, PEA-A18°AA
For details on qualifying for the tax credit, visit
www.mitsubishicomfort.com/taxcredit, and for information on
available local rebate opportunities from state or utility companies,
visit www.dsireusa.org, which is a U.S. Department of Energy
Information service.
Table of Contents
Introduction and Environmental Information
Product Showcase 04
System Overview and Technology 06
System Lineup 08
PKA Wall -Mounted Heat Pump Overview 10
PLA Ceiling -Recessed Heat Pump Overview 10
PEA/PEAD Horizontal Ducted Heat Pump Overview11
H2i® Hyper -Heating INVERTER Overview 12
H2i Heat Pump Specifications 13
PKA Wall -Mounted Specifications 14
PCA Ceiling -Suspended Specifications 16
PLA Ceiling -Recessed Heat Pump Specifications 18
PEA/PEAD Horizontal Ducted Heat Pump Specs 20
H2i Heat Pump Specifications 24
Controllers 26
Accessories 30
Diamondback® Ball Valves 32
Diamondback® Platform Stands 32
Diamondback® Linesets 33
Filter Boxes 33
Line-HideTM 34
Lossnay 34
M -Series / CITY MULTI® Reference 35
Commerical -grade HVAC Applications?
Rely on Mitsubishi Electric's rugged, efficient P -Series
systems to deliver maximum environmental comfort
control plus energy savings for all of your needs.
Whatever P -Series system your client selects, you'll be backed
start to finish with reliable technical and application support
straight from Mitsubishi Electric Cooling and Heating Solutions.
Our innovative technologies, environmentally advanced designs,
and super -efficient systems are the right solution for your
commercial, institutional, and large residential installations.
P -Series air conditioners and heat pumps are the perfect
choice for an array of demanding commercial settings:
• Small or Large Office
• Server/Equipment Room
• Retail Shop
• Restaurant Kitchen
• tt ss Center
• Classro
:MITSUBISHI ELECTRIC visit www.MitsubishiPro.com
PCA Indoor Unit
Discover How State -of -the -Art Technology Drives
De Denc able High Performance in the P -Series .
Meet your customers' needs with
cooling -only (PUY) or combination heat
pump (PUZ) models. Each is compatible
with any of the P -Series indoor units.
You and your clients benefit from a wide
range of installation possibilities.
Every rugged outdoor unit is completely
assembled, piped, wired, and test -run
at the factory prior to shipment. The
heavy-duty, commercial -grade cabinet
is constructed of galvanized steel plate,
finished with electrostatically applied,
thermally fused acrylic or polyester
powder coating for superb corrosion
protection. The front fan grille is tough,
high -impact ABS plastic.
Highly efficient Mitsubishi Electric
INVERTER -driven compressors for
models PUY/Z (A18/24/30/36) are DC twin -rotor type. The compressor for model PUY/Z (A42) is a
Framed Compliant Scroll compressor. All compressors offer high performance due to advanced variable -speed
INVERTER -drive technology, which varies the compressor speed dynamically to adapt continuously to the room
load. Excellent efficiency and significant energy savings are the result.
Quality construction in every Mitsubishi Electric P -Series
unit sets the standard for all HVAC brands in North America.
Feature
INVERTER Technology
Indoor unit powered by outdoor unit
Rugged housing, tough cabinet finish,
strong welds at numerous stress points
Durable, aerodynamic fan design
Quiet cooling operation down to 0" F*
L -shape condenser coil features copper
tubing and aluminum fins
Cabinet mounting and construction are
designed to withstand 155 MPH
Easy interior access to every P -Series
indoor and outdoor unit
Benefit
Maximum energy -efficiency, precise temperature
control, more consistent comfort in every space
Separate power supply not needed '+
Durability for years of reliable service
Super -quiet operation at all speeds
High performance for all climates, south to north,
east to west
Greatly reduced debris accumulation that allows
maximum airflow
Peace of mind for customers in tomado/
hurricane -prone areas
More efficient and less costly routine
maintenance and servicing
• With optional wind baffle added
Electronic linear expansion valves are employed to meter precisely and provide fine controls to adapt continuosly,
the refrigerant flow, ensuring exact capacity delivery. Mitsubishi P -Series outdoor models also utilize advanced
Pulse Amplitude Modulation (PAM) circuitry. PAM adjusts the form of the current output wave to emulate the form of
the supply voltage wave. These technological features offer the advantage that 98 percent of input power is utilized.
PUY/PUZ-NHA4
Cooling -only and Heat Pump
12,000 to
18,000 Btu/h
6 :MITSUBISHI ELECTRIC
24,000 to
36,000 Btu/h
42,000 Btu/h
visit www.MitsubishiPro.com
Va.
PUZ-HA**NHA2 (H2i®)
Hyper -Heating INVERTER
30,000 to
36,000 Btu/h
Mitsu sishi Electric
System Technologies
Housed in the outdoor unit, the Mitsubishi Electric INVERTER -driven compressor respond
to advanced sensor technology to detect subtle changes in temperature. Like a car's cruise
control, the sensors automatically adjust compressor speed to adjust system output perfectly.
INVERTER -driven compressors dramatically reduce the system's energy use, unlike conventional
units that run only at one speed, resulting in an endless wasteful) cycle of starting and stopping.
R
ENERGY STAR
PARTNER
Flexible Control
User-friendly and efficient zone
control gives your customers
the option to cool or heat only those
Wafts tocnnaroar
spaces which are occupied. The controller does not
even have to be in the space shared with the indoor unit.
Among the energy-saving features of the controller are a
weekly timer, temperature range limiting, auto -off, fault
code notification, and service -call number display.
Easy -Care Filters
Convenient tabs make it easy for anyone to remove
the washable filters quickly for faster cleaning in the
PKA, PCA, and PLA indoor units. Your customers will
also save time and money because they won't need to
replace the filters. PEA/PEAD models offer optional filter
boxes for easy access and service.
Auto Cooling/Heating Changeover
When set to auto mode, P -Series systems continuously
monitor indoor air temperatures, sensing when a space
needs cooling or heating. The units automatically switch
operation as needed to maintain a consistent level
of comfort.
Bring in Outside Air
You will be able to install ducting with minimal on-site
work to bring in outside air for PCA, PLA, and PEA/PEAD
indoor units. A healthy, comfortable indoor environment
is the result. Energy Recovery Ventilators (ERVs) with
integrated controls are also available. Outside air
ventilation systems, ducting, and controls are
provided separately.
INVERTER Compressor
Shown inside insulated compartment
visit www.MitsubishiPro.com
:MITSUBISHI ELECTRIC
7
MUitsu
sishi Electric
System Technologies
In Mitsubishi's P -Series, Four Types of High -Performance Indoor Models Let You Match with a
Versatile Lineup of Efficient, INVERTER -driven Outdoor Units to Provide a Truly Custom Solution.
P -SERIES INDOOR UNITS:
PKA Wall -mounted Air Conditioners and Heat Pumps
12,000-34,200 Btu/h
• Sleek, slim -line design
• Ductless installation
• RedLINKTM enabled for wall -mounted wireless, hand-held
wireless or wired controller
• Easy -clean, washable filter
• Ideal for spaces such as churches, classrooms, daycare
centers, out buildings, small offices, and more
PLA Ceiling -recessed Air Conditioners and Heat Pumps
12,000-42,000 Btu/h
• Space -efficient ductless installation
• Built-in condensate lift mechanism
• Knockouts for ventilation air and branch duct run
• Optional i -see sensor for precise temperature control
• Easy -clean, washable filter (optional high -efficiency filter
available — requires multifunction casement)
• RedLINK enabled for wall -mounted wireless hand-held
wireless or wired controller easy -clean, washable filter
• Ideal for intermediate retail shops, classrooms, office spaces,
conference centers, building lobbies, and more
PCA Ceiling -suspended Air Conditioners and Heat Pumps
24,000-42,000 Btu/h
• Slim, powerful indoor unit design
• Ductless installation
• Knockout for ventilation air
• Optional i -see sensor for precise temperature control
• RedLINK enabled for wall -mounted wireless hand-held,
wireless or wired don trolIer
• Easy -clean, washable filter
• Ideal for larger retail stores, classrooms, restaurants,
office spaces, building entrances, plus energy-efficient
additions, renovations, and more
• Suspends from ceiling for quick easy install
PEA/PEAD Horizontal -ducted Air Conditioners and Heat Pumps
12,000-42,000 Btu/h
• Unobtrusive concealed ceiling design for short -run ductwork
• Built-in condensate lift mechanism
• Automatic fan speed control
• RedLINK enabled for wall -mounted wireless hand-held,
wireless or wired controller
• Optional filter boxes for easy
access and service
• Ideal in retail shopping centers, larger classrooms, auditoriums,
office complexes, conference ballrooms, fitness centers, and more
•
8 .'.MITSUBISHI ELECTRIC visit www.MitsubishiPro.com
See page 26 for
information on the
MHK1 Remote
Controller Kit
IVitsuoishi Electric
System Technologies
et tilt a
1:3 ":1,4 till
tt to tt t: Ittt
"9zit!:ttti1 I
`011 ft *ill sell r
stiff fat tut I
144 tet iui t _-
Ititie11ii iii t.
iiIItti;! :Ai °ris
f�
:ttt:it t:.j 1 '
i;t4'i` .:*4 1
esti It ft tttit !•,
*tt !!i!!!!' '.•
Ultimate Comfort Meets Ultimate Convenience
Select from a wall -mounted, wireless wall -mounted, or
hand-held wireless controller for ultimate comfort control.
(PKA-HA/KA) for ultimate comfort control or a handheld
wireless controller. The set -temperature display is large
and easy to read. Using the 24-hour timer, you can get
the unit operation to start and stop at specified times.
The convenient remote provides easy control of the fan
speed as well as the Cool, Heat, Auto, and Dry modes
from anywhere in the room. The hand-held wireless
remote controller is easier to use than most TV remotes
for P -Series systems.
Lightweight, Easy -to -install Indoor Unit
The smallest PKA unit measures about 36" wide, 11-
1/2" tall, and 9-3/4" deep. It weighs just 29 lbs., is easily
installed above windows or doorways, and can typically
be installed by just two licensed installers in about a half
day. The wall -mounted models don't require duct work,
only a small three-inch opening in the wall or ceiling so
they can be installed in some of the toughest spaces
even on brick and masonry walls.
Auto Vane Control
During operation the vane can be adjusted with the
remote controller to the perfect position to direct the
airflow horizontally in cooling mode or towards the floor
in heating mode, keeping room temperature even and
comfortable. A simple press of the OFF button results
in the vane closing the air outlet for a clean presentation
when not in use.
Control Airflow Angle for Better Coverage
With the wired remote controller four different airflow
positions can be set. The AUTO vane feature when in
use during cooling permits the angle to self -adjust into a
horizontal position and circulate cold air more effectively.
During heating the vane directs the hot air downward
toward the floor where it will rise and circulate, keeping
your room comfortable from top to bottom. The vane
closes completely.
i-seeTM Sensor Optional Accessory
The field -installed i -see sensor accessory improves
the operation in the room by sensing and controlling
the temperature felt by the room's occupants to help
prevent cooling and heating extremes (optional for PU
PC models). Taking floor temperature samples five
times every 40 seconds over a 160° angle of the surface
area, sensors alter the AUTO FAN setting and VANE
control setting to account for ambient room temperature
fluctuations from the set point.
visit www.MitsubishiPro.com ..MITSUBISHI ELECTRIC 9
Vitsu
Dish Electric
System Technologies
i-seeTM Sensor Optional Accessory % eeSensor
In addition to the return air temperature sensor, the PLA-A**BA four-way ceiling cassette
with the field -installed i -see sensor measures the floor temperature in real time, observing
the room vertically for better management of sensible temperature (temperature
felt by the occupant). The i -see sensor measures the infrared rays
generated from the surrounding wall and floor surface at an angle
of 360°. The infrared ray energy, is converted into a temperature
value. The i -see sensor rotates 90° slowly in five -second
intervals for correct measurement of temperature to cover
the full floor space. When combined with the auto fan speed --
mode, air can be directed to the farthest corners of the
room for enhanced temperature coverage.
i -see sensor detail
One Indoor Room
Outdoor Unit
Two -in -one Twinning
If you have a large space such as a long room or hallway which would be considered
one zone, two indoor units can be connected to one outdoor unit to cool or heat the
space, providing the maximum amount of comfort. The process in which two indoor
units act as one to spread the outdoor unit's: capacity over a large area is called
twinning.
10 .:MITSUBISHI ELECTRIC visit www.MitsubishiPro.com
V itsu dish i Electric
System Technologies
PEA/PEAD horizontal ducted series
Built-in Drain Lift Mechanism
The PEA indoor unit features a built-in drain
pump that lifts condensation up to 21-11/16
inches above the drain pan and up to 27-9/16
inches for the PEAD indoor unit. The unit's fail-safe
mechanism recognizes when there is a high level
in the condensate pan and shuts off the indoor fan
and the outdoor unit compressor to prevent overflow.
When installed, the PEA/PEAD indoor unit utilizes short duct
runs, allowing for the air conditioning of adjacent spaces or
extending the range of distributed capacities within a single
zone with very little visual impact to the conditioned area.
With features like a built-in condensate lift mechanism, adjustable static pressure, multiple fan
speeds, DRY Mode, and an operating sound as low as 23 dB(A), the PEA/PEAD systems expand
the number of application possibilities.
PEA
PEAD
visit www.MitsubishiPro.com
MITSt1815Ht ELECTRIC 11
P -Series Hyper -Heating
BRINGING YEAR-ROUND COMFORT
SOLUTIONS TO EXTREME CLIMATES.
Heat Pump System:
30,000 to 34,000 Btu/h Capacity
NVERTER
Unequaled Year-round Comfort
The dual cooling and heating performance of Mitsubishi
Electric's INVERTER -driven heat pump systems is
appreciated by commercial businesses all across the
country. You'll find our Hyper -Heating INVERTER (H2i)
P -Series technology advances the benefits a step further
with the ultimate in year-round comfort in a single system.
The efficient performance and comfort extend to even the
coldest days of the year in most areas.
The 2.5 and 3 -ton wall -mounted, ceiling -suspended,
ceiling -recessed, and ducted units connect to the
H2i P -Series outdoor units. This capability gives you
customized performance flexible enough to excel in any
light commercial application, institutional renovation, or
new construction project. Rugged construction ensures
cold -weather reliability.
The Next Generation in Heat Pump Technology
H2i P -Series outdoor units optimize a new level of
performance to Mitsubishi Electric P -Series models,
furnishing the extra heat -generating power needed to
deliver comfort and consistency in extreme climates.
H2i units use Mitsubishi's INVERTER -driven scroll
compressor technology to achieve the desired room
temperature quickly, maintaining it consistently while
simultaneously conserving energy. Best of all, the
integration of our exclusive H2i flash technology means
these H2i P -Series units recover heat energy that is
normally wasted in the flash process at the outdoor
coil. H2i flash technology helps the system overcome
issues associated with conventional heat pumps such
as decreases in low -side pressure, refrigerant mass flow
rate, and operational capacity. What you'll see is the
H2i P -Series units deliver 100 percent of rated heating
capacity at 5° F and 80 percent at minus 13° F outdoor
ambient temperatures (without the use of energy -
consuming electric -resistance heaters). Plus H2i systems
use R410A a more efficient and environmentally safe
refrigerant.
H2i P -Series heat pumps also offer a variety of features
designed to take the worry out of temperature control.
Two important features are automatic restart after a
power outage plus automatic cool/heat changeover.
Finally, H2i heat pumps offer long line -length capabilities
of up to 245ft., expanding your application options.
6i
°.r
{
Some spaces such as computer or mechanical
rooms, or hot kitchens require a distribution of cool air
even when the temperature outside is below freezing.
Air conditioning down to 0° F is achievable with the
addition of wind baffles. Whether cooling or heating,
the H2i P -Series helps you offer your clients the
flexibility to temper extreme outdoor temperatures.
Warm Air Quickly
At startup a special circuit in H2i P -Series quickly
delivers refrigerant to the air-conditioning cycle,
which rapidly increases the mass flow rate in the
system. As a result, air at comfortable temperatures
begins flowing from indoor units right away. Even at
an outdoor temperature of -13° F, the H2i P -Series
system can discharge 100° F temperature air from the
indoor units. At 5° F outdoor temperature and above,
the discharge temperature reaches an impressive
110° F with a 40° F temperature rise (see Figure 2).
This feature translates into a comfortable climate in
all zones whether cooling or heating, no matter the
temperature outside.
12 Att.MITSUBISHI EIECTRtC visit www.MitsubishiPro.com
IV itsu sishi Electric
P -Series Hyper -Heating
(Figure 1)
Hyper -Heating INVERTER vs. Other Units
Heating Capacity vs- Outdoor Temperature
120-�
100
80 Y
U
c
x
60
40
1
•
20
0'
-13 -4 0 5 10 17 25 30 35 40 47
Outdoor Temperature Degrees FWB
(Figure 2)
110
108
106
104
102
i;, 100
m
v 98
N
CI 96 r ;
-4—Mitsubishi Electric Hyper -Heating INVERTER (H2i1
—F Mitsubishi Electric Standard INVERTER heat pump system
—1 -Typical Unitary Equipment Performance
Does not include correction factor for defrost
Indoor Unit Discharge Temperature
(wall -mounted indoor unit with fan on high)
94
-13 -4
Outdoor Temperature (° F WB)
ENERGY STAR® and Tax Credit Systems
Nine (9) H2i P -Series systems are ENERGY STAR rated,
and two (2) systems qualify for the federal tax credit.
ENERGY STAR
PUZ-HA3ONHA
COP if
PKA
PLA
PCA
PEAD
47° F
3.20
2.72
3.13
3.41
17° F
1.84
1.63.
1.81
1.90
5° F
1.62
1.41
1.60
1.73
PUZ-HA36NHA
CAW it
I'I(A
FLA
t UA
I tAD
47° F
3.26
3.44
3.40
3.53
17° F
1.85
2.10
1.94
2.06
5° F
1.64
' 1.90
1.70
1.82
ENERGY STAR Tax Credit
PKA-A3OKA4 PLA-A36BA4
PKA-A36KA4 PEA -A1 8AA4(x2)
PLA-A3OBA4
PLA-A36BA4
PCA-A30KA4
PCA-A36KA4
PEA -Al 8AA4(x2)
PEAD-A30AA4
PEAD-A36AA4
Heating Performance at Low Temperatures,
OurrHyper: Heating INVERTER system provides outstanding
heating performance at extremely low temperatures while
keeping effective energy usage at the forefront° See the
impressive COP (Coefficient of Performance) values in
the table to the left. The Mitsubishi H2i P -Series systems
are able to maximize efficiency at low temperatures while
providing tremendous heating output.
visit www.MitsubishiPro.com :MITSUBISHI ELECTRIC 13
BS = Seacoast Protection
•
(PKA-A30)1 MODEL SHOWN)
PKA COOLING -ONLY
Model Name
Cooling *1
Indoor Unit
Outdoor Unit
Rated Capacity
Btulh
PKA-Al2HA4
PUY-Al2NHA4 -BS
12,000
PKA-A18HA4
PUY-A1BNHA4 -BS
PKA-A24KA4
PUY-A24NHA4 -BS
24,000
PKA-A30KA4
PUY-A3ONHA4 -B
30,000
PKA-A36KA4
PUY-A36NHA4 -BS
34,200
18,000
Capacity Range
Btu/h
6,000-12,000
8,000-18,000
12,000-24,000
12,000-30,000
•
12,000-34,200
Total Input
W
1,190
2,240
2,270
4,130
5,030
Energy Efficiency
SEER
15.2
15.3
17.0
15.5
14.0
Moisture Removal
Pintsm
2.0
5.2
5.0
8.1
9.2
Sensible Heat Factor
0.81
0.68
0.77
0.70
0.70
Power Supply
Phase, Cycle, Voltage
1 -phase, 60Hz, 208 / 230V *2
Voltage
Indoor - Outdoor S1 - S2
AC 208 / 230V
Indoor - Outdoor S2 - S3
DC24
Indoor Unit
MCA
A
1
Fan Motor
F.L.A.
0.33
0.36
0.57
Fan Motor Output
W
30
56
56
Airflow (Lo -Mid -Hi)
DRY (CFM)
320-370-425
635-705-775
705-810-920
WET (CFM)
290-335-380
570-635-700
635-730-830
Sound Pressure Level (Lo -Mid -Hi)
dB(A)
36-40-43
39-42-45
43-46-49
External Finish Color
Munsell No. 1.OY 9.2 / 0.2
Dimension Unit
W: In.
35-3/8
46-1/16
D: In.
9-13/16
11-5/8
H: In.
11-5/8
14-3/8
Weight Unit
Lbs.
29
46
Field Drainpipe Size 0.D.
In.
5/8
Outdoor Unit
MCA
A
13
18
25
Recommended Fuse/Breaker Size
A
15
25
30
MOCP
A
15 1 20
30
40
Fan Motor
FL A
0.35
0 75
Fan Motor Output
W
40
75
Compressor
Model (Type)
DC INVERTER -driven Twin Rotary
R.L.A.
12
L.R.A.
14
17.5
Airflow
CFM
1,200
1 1,940
Refrigerant Control
Linear Expansion Valve
Sound Pressure Level at Cooling *1 dB(A)
46
48
External Finish Color
Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In.
31-1/2
37-3/8
D: In.
11-13/16 + 7/8
13 + 1-3/16
H: In.
23-5/8
37-1/8
Weight
Lbs.
82 1 89
163
Refrigerant
Type
R410A
Charge
Lbs., oz.
2,14 3,12
6,10
Oil
Type
(fl. oz.)
FV5OS (20)
FV5OS (28)
Refrigerant Pipe
Gas Side O.D.
In.
1/2
5/8
Liquid Side 0.D.
In.
1/4
3/8
Refrigerant Pipe Length
Height Difference (Max.)
Ft.
100
Length (Max.)
Ft.
100
165
Connection Method
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C).
*2. Indoor units receive power from outdoor units through field -supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY ISeven-year warranty on compressor. Five-year warranty on parts.
14 .MITSUBISHI ELECTRIC visit www.MitsubishiPro.com
(PKA-A30KA4 MODEL SHOWN)
PKA HEAT PUMP
ER
BS = Seacoast Protection
Model Name
Cooling *1
Indoor Unit
Outdoor Unit
Rated Capacity
Btu/h
PKA-A18HA4
PUZ-A18NHA4 -BS
18,000
PKA-A24KA4
PUZ-A24NHA4 -BS
24,000
PKA-A3OKA4
PUZ-A3ONHA4 -BS
30,000
PKA-A36KA4
PUZ-A36NHA4 -BS
34,200
Capacity Range
Btu/h
8,000-18,000
12,000-24,000
12,000-30,000
12,000-34,200
Total lnput
W
2,240
2,270
4,130
5,030
Energy Efficiency
SEER
15.3
17.0
15.5
14.0
Moisture Removal
Pints/h
5.2
5.0
8.1
9.2
Sensible Heat Factor
0.68
0.77
0.70
0.70
Heating at 47° F'2
Rated Capacity
Btu/h
19,000
26,000
32,000
37,000
Capacity Range
Btu/h
8,000-20,000
12,000-28,000
12,000-34,000
12,000-38,000
Total Input
W
1,970
2,330
3,150
3,610
HSPF (IV)
Btu/h/W
9.5
10.8
8.9
9.3
Heating at 17° F'3
Capacity
Btu/h
13,000
18,000
23,000
25,000
Total Input
W
1,670
2,200
2,850
3,030
Power Supply
Phase, Cycle, Voltage
1 -phase, 60Hz 208 / 230V *4
Voltage
Indoor - Outdoor S1 - S2
AC 208 / 230V
Indoor - Outdoor S2 - S3
DC24
Indoor Unit
MCA
A
1
Fan Motor
F.L.A.
0.33
0.36
0.57
Fan Motor Output
W
30
• 56
56
Airflow (Lo -Mid -H1)
DRY (CFM)
320-370-425
635-705-775
705-810-920
WET (CFM)
290-335-380
570-635-700
635-730-830
Sound Pressure Level (Lo -Mid -Hi)
dB(A)
36-40-43
39-42-45
43-46-49
External Finish Color
Munsell No. 1.0Y 9.2 / 0.2
Dimension Unit
W: In.
35-3/8
46-1/16
D: In.
9-13/16
11-5/8
H: In.
11-5/8
14-3/8
Weight Unit
Lbs.
29
46
Field Drainpipe Size 0.D.
In.
5/8
Outdoor Unit
MCA
A
13
18
25
Recommended Fuse/Breaker Size
A
15
25
30
MOCP
A
20
30
40
Fan Motor
F.L.A.
0.35
0.75
Fan Motor Output
W
40
75
Compressor
Model
(Type)
DC INVERTER -driven Twin Rotary
R.L.A.
12
L.R.A.
14 17.5
Airflow
CFM
1,200 1 1,940
Refrigerant Control
Linear Expansion Valve
Defrost Method
Reverse Cycle
Sound Pressure Level at Cooling *1
dB(A)
48
Sound Pressure Level at Heating *2
dB(A)
47 50
External Finish Color
Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In.
31-1/2
37-3/8
0: In.
11-13/16 +7/8
13 + 1-3/16
H: In.
23-5/8
37-1/8
Weight
Lbs.
91
165
Refrigerant
Type
R410A
Charge
Lbs., oz.
3,12
6, 10
Oil
Type (fl. oz.)
FV5OS (20)
FV5OS (28)
Refrigerant Pipe
Gas Side O.D.
In.
1/2
5/8
Liquid Side O.D.
In.
1/4
3/8
Refrigerant Pipe Length
Height Difference (Max.)
Ft
100
Length (Max.)
Ft.
100 165
Connection Method
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
I. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor. D.B. 95° F (35° C), W.B. 75° F (24° C).
'2. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: O.B. 47° F (8° C), W.B. 43° F (6° C).
*3. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: D.B. 17° F (-8.3° C), W.B. 15° F (-9° C).
*4. Indoor units receive power from outdoor units through field -supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on parts.
visit www.MitsubishiPro.com
.tMrTSUBISHI ELECTRIC 15
Ityairz R
PCA COOLING -ONLY
(PCA-A36KA4 MODEL SHOWN)
BS = Seacoast Protection
Model Name
Cooling *1
Indoor Unit
Outdoor Unit
Rated Capacity
Btu/h
PCA-A24KA4
PUY-A24NHA4 -BS
24,000
PCA-A30KA4
PUY-A3ONHA4 -BS
30,000
PCA-A36KA4
PUY-A36NHA4 -BS
35,000
PCA-A42KA4
PUY-A42NHA4 -BS
42,000
Capacity Range
Btu/h
12,000-24,000
12,000-30,000
12,000-35,000
18,000-42,000
Total Input
W
2,340
3,760
4,630
4,110
Energy Efficiency
SEER
16.8
14.5
14.4
15.8
Moisture Removal
Pints/h
5.8
8.3
8.5
11.7
Sensible Heat Factor
0.73
0.69
0.73
0.69
Power Supply
Phase, Cycle, Voltage
1 -phase, 60Hz, 208 / 230V'2
Voltage
Indoor - Outdoor S1 - S2
AC 208 / 230V
Indoor - Outdoor S2 - S3
DC24V
Indoor Unit
MCA
A
1
2
Fan Motor
F.L.A.
0.54
0.97
Fan Motor Output
W
95
160
Airflow (Lo-M1-M2-Hi)DRY
(CFM)
530-565-600-670
565-600-635-705
775-850-920-990
810-885-955-1,025
WET (CFM)
495-530-565-635
530-565-600-670
705-775-850-920
740-810-885-955
Sound Pressure Level (Lo -M1 -M2 -Hi)
dB(A)
33-35-37-40
35-37-39-41
37-39-41-43
39-41-43-45
External Finish Color
Munsell No. 6.4Y 8.9 / 0.4
Dimension Unit
W: In.
50-3/8 1 63
D: In.
26-3/4
H: In.
9-1/16
Weight Unit
Lbs.
71 1 79 1 84
Field Drainpipe Size 0.D.
In.
1-1/16
Outdoor Unit
MCA
A
18
25 1 26
Recommended Fuse/Breaker Size
A
25
30
MOCP
A
30
40
Fan Motor
FLA
0.75
0 4 + 0 4
Fan Motor Output
W
75
86 + 86
Compressor
Model (Type)
DC INVERTER -driven Twin Rotary
INVERTER -driven Scroll
R.LA.
12
20
L.R.A.
14 17.5
27.5
Airflow
CFM
1,940
3,530
Refrigerant Control
Linear Expansion Valve
Sound Pressure Level at Cooling *1 dB(A)
48 51
External Finish Color
Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In.
37-3/8
D: In.
13 + 1-3/16
H: In.
37-1/8
53-1/8
Weight
Lbs.
163
258
Refrigerant
Type
R410A
Charge
Lbs., oz.
6,10
10
Oil
Type M. oz.)
FV5OS (28)
FV50S (45)
Refrigerant Pipe
Gas Side O.D.
In.
5/8
Liquid Side 0.D.
In.
3/8
Refrigerant Pipe Length
Height Difference (Max.)
Ft.
100
Length (Max.)
Ft.
165
Connection Method
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
"1. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C).
*2. Indoor units receive power from outdoor units through field -supplied interconnected wiring.
Specifications are subject to change without notice.
LIMITED WARRANTY ( Seven-year warranty on compressor. Five-year warranty on parts.
16 AMITSUBISHI ELECTRIC Visit www.MitsubishiPro.com
(PCA-A36KA4 MODEL SHOWN)
PCA HEAT PUMP
BS = Seacoast Protection
Model Name
Cooling *1
Indoor Unit
Outdoor Unit
Rated Capacity
Btu/h
PCA-A24KA4
PUZ-A24NHA4 -BS
24,000
PCA-A3OKA4
PUZ-A3ONHA4 -BS
30,000
PCA-A36KA4
PUZ-A36NHA4 -BS
35,000
PCA-A42KA4
PUZ-A42NHA4 -BS
42,000
Capacity Range
Btu/h
12,000-24,000
12,000-30,000
12,000-35,000
18,000-42,000
Total Input
W
2,340
3,760
4,630
4,110
Energy Efficiency
SEER
16.8
14.5
14.4
15.8
Moisture Removal
Pints/h
5.8
8.3
8.5
11.7
Sensible Heat Factor
0.73
0.69
0.73
0.69
Heating at 47° F'2
Rated Capacity
Btu/h
26,000
32,000
37,000
45,000
Capacity Range
Btu/h
12,000-28,000
12,000-34,000
12,000-38,000
18,000-48,000
Total Input
W
2,310
3,210
3,190
3,830
HSPF (IV)
Btu/h/W
10.9
9.2
10.2
10.2
Heating at 17° F'3
Capacity
Btu/h
18,000
23,000
25,000
30,000
Total lnput
W
2,200
2,940
2,800
3,820
Power Supply
Phase, Cycle, Voltage
1 -phase, 60Hz 208 / 230V *4
Voltage
Indoor - Outdoor Si - S2
AC 208 / 230V
Indoor - Outdoor S2 - S3
DC24V
Indoor Unit
MCA
A
1
2
Fan Motor
F.L.A.
0.54
0.97
Fan Motor Output
W
95
160
Airflow (Lo -M1 -M2 -Hi)
DRY (CFM)
530-565-600-670
565-600-635-705
775-850-920-990
810-885-955-1,025
WET (CFM)
495-530-565-635
530-565-600-670
705-775-850-920
740-810-885-955
Sound Pressure Level (Lo -M1 -M2 -Hi)
dB(A)
33-35-37-40
35-37-39-41
37-39-41-43
39-41-43-45
External Finish Color
Munsell No. 6.4Y 8.9 / 0.4
Dimension Unit
W: In.
50-3/8 1 63
D: In.
26-3/4
H: In. •
9-1/16
Weight Unit
Lbs.
71 1 79 1 84
Field Drainpipe Size 0.0.
In.
1-1/16
Outdoor Unit
MCA
A
18
25 1 26
Recommended Fuse/Breaker Size
A
25
30
MOCP
A
30 .
40
Fan Motor
F.L.A.
0.75
0.4 + 0.4
Fan Motor Output
W
75
86 + 86
Compressor
Model (Type)
DC INVERTER -driven Twin Rotary
INVERTER -driven Scroll
R.L.A.
12
20
L.R.A.
14 17.5
27.5
Airflow
CFM
1,940
3,530
Refrigerant Control
Linear Expansion Valve
Defrost Method
Reverse Cycle
Sound Pressure Level at Cooling *1
dB(A)
48
51
Sound Pressure Level at Heating *2
dB(A)
50
55
External Finish Color
Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In.
37-3/8
D: In.
13 + 1-3/16
H: In.
37-1/8
53-1/8
Weight
Lbs.
165
260
Refrigerant
Type
R410A
Charge
Lbs., oz.
6,10
10
Oil
Type (fl. oz.)
FV5OS (28)
FV5OS (45)
Refrigerant Pipe
Gas Side 0.0.
In.
5/8
Liquid Side 0.D.
In.
3/8
Refrigerant Pipe Length
Height Difference (Max.)
Ft.
100
Length (Max.)
Ft.
165
Connection Method
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C).
*2. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: D.B. 47° F (8° C), W.B. 43° F (6° C).
*3. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: 0.6.17° F (-8° C), W.B. 15° F (-9° C).
*4. Indoor units receive power from outdoor units through field -supplied interconnected wiring.
Specifications are subject to change without notice.
visit www.MitsubishiPro.com
LIMITED WARRANTY I Seven-year warranty an compressor.
Five-year warranty on parts.
MITSUBISHI ELECTRIC 17
(PLA-A368A4 MODEL SHOWN
WITH OP11ONAL i -seer" SENSOR)
BS = Seacoast Protection
PLA COOLING -ONLY
Model Name
Cooling *1
Indoor Unit
Outdoor Unit
Rated Capacity
Btu/h
PLA-Al2BA4
PUY-Al2NHA4 (-BS)
12,000
PLA-A18BA4
PUY-A18NHA4 (-BS)
18,000
PLA-A24BA4
PUY-A24NHA4 (-BS)
24,000
PLA-A3OBA4
PUY-A3ONHA4 (-BS)
30,000
PLA-A36BA4 PLA-A42BA4
PUY-A36NHA4 (-BS) PUY-A42NHA4 (-BS)
35,000
42,000
Capacity Range
Btu/h
6,000-12,000
8,000-18,000
12,000-24,000
12,000-30,000
12,000-35,000
18,000-42,000
Total Input
W
1,260
1,940
2,500
4,100
4,500
4,600
Energy Efficiency
SEER
13.5
14.2
13.6
14.2
14.4
Moisture Removal
Pints/b
1.7
3.0
5.1
7.2
8.1
10.9
Sensible Heat Factor
0.84
0.81
0.76
0.73
0.74
0.71
Power Supply
Phase, Cycle, Voltage
1 -phase, 60Hz, 208 / 230V *2
Voltage
Indoor - Outdoor S1 - S2
AC 208 / 230V
Indoor - Outdoor S2 - S3
DC24V
Indoor Unit
MCA
A
1
2
Fan Motor
F.L.A.
0.51
1.00
Fan Motor Output
W
50
120
Airflow (Lo -Ml -M2-Hi)
DRY
(CFM)
390-420-460-530
420-490-570-640
490-570-640-740
710-810-920-1,060
780-880-990-1,090
WET
(CFM)
350-390-420-490
390-460-530-600
460-530-600-710
670-770-880-1,030
740-850-950-1,060
Sound Pressure Level
(Lo -M1 -M2 -Hi)
dB(A)
27-28-29-31
28-29-31-32
28-30-32-34
32-34-37-40
34-36-39-41
External Finish Color (Panel)
Munsell No. 6 4Y 8.9 / 0.4
Dimension Unit (Panel)
W: In.
33-1/16 (37-3/8)
D: In.
33-1/16 (37-3/8)
H: In.
10-3/16 (1-3/8)
11-3/4 (1-3/8)
Weight Unit (Panel)
Lbs.
49 (13) I 51 (13)
55 (13)
Drain Lift Mechanism
(Included)
H: In.
33-7/16
Field Drainpipe Size 0.D.
In.
1-1/4
Outdoor Unit
MCA
A
13
18
25 ] 26
Recommended Fuse/
Breaker Size
A
15
25
30
MOCP
A
15 1 20
30
40
Fan Motor
F.L.A.
0.35
0.75
0.4 + 0.4
Fan Motor Output
W
40
75
86 + 86 .
Compressor
Model
(We)
DC INVERTER -driven Twin Rotary
INVERTER driven
Scroll
R.LA.
12
20
L.R.A.
14 17.5
27.5
Airflow
CFM
1,200 1 1,940
3,530
Refrigerant Control
Linear Expansion Valve
Sound Pressure Level at
Cooling *1
dB(A)
46
48
51
External Finish Color
Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In.
31-1/2
37-3/8
D: In.
11-13/16+ 7/8
13+1-3/16
H: In.
23-5/8
37-1/8
53-1/8
Weight
Lbs.
82 1 89
163
258
Refrigerant
Type
R410A
Charge
Lbs.,
oz.
2 4
3, 12
6, 10
10
Oil
Type
(fl. oz.)
FV50S(20)
FV50S(28)
FV50S(45)
Refrigerant Pipe
Gas Side 0.D.
In.
1/2
5/8
Liquid Side O.D.
In.
1/4
3/8
Refrigerant Pipe
Length
Height Difference (Max.)
Ft.
100
Length (Max.)
Ft.
100 165
Connection
Method
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
"1. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor. D.B. 95° F (35° C), W.B. 75° F (24° C).
"2. Indoor units receive power from outdoor units through field -supplied interconnected wiring.
Specifications are subject to change without notice.
UNITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
18 ..MITSUBISHI ELECTRIC
visit www.MitsubishiPro.com
PLA HEAT PUMP
(PLA-A36BA4 MODEL SHOWN
WITH OPTIONAL I -see. SENSOR)
BS = Seacoast Protection
Model Name
Cooling *1
Indoor Unit
Outdoor Unit
Rated Capacity
Btu/h
PLA-A18BA4
PUZ-A18NHA4 -BS
18,000
PLA-A24BA4
PUZ-A24NHA4 -BS
24,000
PLA-A3OBA4
PUZ-A3ONHA4 -BS
30,000
PLA-A36BA4
PUZ-A36NHA4 -BS
35,000
PLA-A42BA4
PUZ-A42NHA4 -BS
42,000
Capacity Range
Btu/h
8,000-18,000
12,000-24,000
12,000-30,000
12,000-35,000
18,000-42,000
Total lnput
W
1,940
2,500
4,100
4,500
4,600
Energy Efficiency
SEER
14.2
13.6
14.2
14.4
Moisture Removal
Pints/h
3.0
5.1
7.2
8.1
10.9
Sensible Heat Factor
0.81
0.76
0.73
0.74
0.71
Heating at 47° F'2
Rated Capacity
Btu/h
19,000
26,000
32,000
37,000
45,000
Capacity Range
Btu/h
8,000-20,000
12,000-28,000
12,000-34,000
12,000-38,000
18,000-48,000
Total Input
W
1,900
2,570
3,370
3,300
4,450
HSPF (110
Btu/h/W
9.8
8.5
8.7
9.3
Heating at 17° F'3
Capacity
Btu/h
13,000
16,000
23,000
25,000
30,000
Total Input
W
1,590
2,200
3,050
3,070
4,300
Power Supply
Phase, Cycle, Voltage
1 -phase, 60Hz, 208 / 230V'4
Voltage
Indoor - Outdoor S1 - S2
AC 208 / 230V
Indoor - Outdoor S2 - S3
OC24V
•dB(A)
Indoor Unit
MCA
A
1
2
Fan Motor
F.L.A.
0.51
1.00
Fan Motor Output
W
50
120
Airflow (Lo -M1 -M2 -Hi)
DRY (CFM)
420-490-570-640
490-570-640-740
710-810-920-1,060
780-880-990-1,090
WET (CFM)
390-460-530-600
460-530-600-710
670-770-880-1,030
740-850-950-1,060
Sound Pressure Level (Lo-M1-
M2 -Hi)
28-29-31-32
28-30-32-34
32-34-37-40
34-36-39-41
External Finish Color (Panel)
Munsell No. 6.4Y 8.9 / 0.4
Dimension Unit (Panel)
W: In.
33-1/16 (37-3/8)
D: In.
33-1/16 (37-3/8)
H: In.
10-3/16 (1-3/8)
11-3/4 (1-3/8)
Weight Unit (Panel)
Lbs.
49 (13) 1 51 (13)
55 (13)
Drain Lift Mechanism (Included)
H: In.
33-7/16
Field Drainpipe Size 0.D.
In.
1-1/4
Outdoor Unit
MCA
A
13
18
25 1 26
Recommended Fuse/Breaker Size
A
15
25
30
MOCP
A
20
30
40
Fan Motor
F.L.A.
0.35
0.75
0.4 + 0.4
Fan Motor Output
W
40
75
86 + 86
Compressor
Model
(Type)
DC INVERTER -driven Twin Rotary
INVERTER -driven Scroll
R.L.A.
12
20
L.R.A.
14 17.5
27.5
Airflow
CFM
1,200 1 1,940
3,530
Refrigerant Control
Linear Expansion Valve
Defrost Method
Reverse Cycle
Sound Pressure Level at Cooling *1
dB(A)
48
51
Sound Pressure Level at Heating *2
dB(A)
47 50
55
External Finish Color
Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In.
31-1/2
37-3/8
D: In.
11-13/16 + 7/8
13 + 1-3/16
H: In.
23-5/8
37-1/8
53-1/8
Weight
Lbs.
91
165
260
Refrigerant
Type
R410A
Charge
Lbs., oz.
3,12
6,10
10
Oil
Type (0.
oz.)
FV5OS (20)
FV5OS (28)
FV5OS (45)
Refrigerant Pipe
Gas Side 0.D.
In.
1/2
5/8
Liquid Side 0.D.
In.
1/4
3/8
Refrigerant Pipe
Length
Height Difference (Max.)
Ft.
100
Length (Max.)
Ft.
100 165
Connection Method
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1 Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C);
Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C).
*2 Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C);
Outdoor: D.B. 47° F (8° C), W.B. 43° F (6.1° C).
LIMITED WARRANTY I Seven-year warranty on compressor.
Five-year warranty on pans.
visit www.MitsubishiPro.com
*3. Rating conditions (heating) -Indoor. D.B. 70° F (21° C), W.B. 60° F (16° C);
Outdoor: D.B. 17° F (-8° C), W.B. 15° F (-9° C).
*4. Indoor units receive power from outdoor units through field -supplied
interconnected wiring.
Specifications are subject to change without notice.
MITSUBISHI ELECTRIC 19
(PEA 'At8AA4 MODEL SHOWN)
BS = Seacoast Protection
PEA/PEAD COOLING -ONLY
Model Name
Cooling *1
Indoor Unit
Outdoor Unit
Rated Capacity
Btu/h
PEA-Al2AA4 PEA-A18AA4 PEAD-A24AA4 PEAD-A30AA4 PEAD-A36AA4
PUY-Al2NHA4 -BS PUY-A18NHA4 -BS PUY-A24NHA4 -BS PUY-A3ONHA4 -BS PUY-A36NHA4 -BS
PEAD-A42AA4
PUY-A42NHA4 -BS
42,000
12,000
18,000
24,000
30,000
35,000
Capacity Range
Btu/ft
6,000-12,000
8,000-18,000
12,000-24,000
12,000-30,000
12,000-35,000
18,000-42,000
Total lnput
W
1,240
2,150
2,400
3,850
4,850
5,350
Energy Efficiency
SEER
13.8
14.3
16.0
15.5
15.0
13.8
Moisture Removal
Pints/h
2.47
3.26
6.9
8.6
7.9
9.0
Sensible Heat Factor
0.77
0.80
0.68
0.75
0.76
Power Supply
Phase, Cycle, Voltage
1 -phase, 60Hz, 208 / 230V *2
Voltage
Indoor - Outdoor S1 - S2
AC208/230V
Indoor - Outdoor S2 - S3
DC24V
Indoor Unit
MCA
A
1
2
2.63
2.73
3.30
3.50
Fan Motor
F.L.A.
0.57
0.74
2.10
2.18
2.64
2.80
Fan Motor Output
W
96
121
244
Airflow (Lo -Mid -Hi)
DRY
(CFM)
247-317-388
423-529-635
512-636-742
618-742-883
847-1,024-1,201
1,042-1,254-1,483
WET
(CFM)
222-285-349
381-476-572
494-600-671
565-671-812
777-953-1,130
953-1,165-1,412
External Static Pressure
In. WG
0.02 - 0.06 0.14 - 0.20
0.14 - 0.20 - 0 28 - 0.40 - 0.60
Sound Pressure Level
(Lo -Mid -Hi)
dB(A)
23-28-33
30-34-38
30-33-37
30-34-39
33-38-42
36-40-44
External Finish Color
Galvanized -steel Sheet
Dimension Unit
W: In.
39 1 46-7/8
43-5/16 1 55-1/8
D: In.
27-9/16
28-7/8
H: In.
7-7/8
9-7/8
Weight Unit
Lbs.
48 1 62
73 1 91 1 95
Drain Lift Mechanism
(Included)
H: In.
21-11/16
27-9/16
Field Drainpipe Size
0.D.
In.
1-1/4
Outdoor Unit
MCA
A
13
18
25 26
Recommended Fuse/
Breaker Size
A
15
25
30
MOCP
A
15 1 20
30
40
Fan Motor
F.L.A.
0.35
0.75
0.4 + 0.4
Fan Motor Output
W
40
75
86 + 86
Compressor
Model
(TYPO
INVERTER -driven Twin Rotary
INVERTER -driven
Scroll
Scroll
R.L.A.
12
20
L.R.A.
14 1 17.5
27.5
Airflow
CFM
1,200 1,940
3,530
Refrigerant Control
Linear Expansion Valve
Sound Pressure Level at
Cooling '1
dB(A)
46
48
51
External Finish Color
Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In.
31-1/2
37-3/8
D: In.
11-13/16 + 7/8
13 + 1-3/16
H: In.
23-5/8
37-1/8
53-1/8
Weight
Lbs.
82 1 89
163
258
Refrigerant
Type
R410A
Charge
Lbs.,
Oz.
2 14
3,12
6,10
10
011
Type (fl.
oz.)
FV5OS (20)
FV5OS (28)
FV5OS (45)
Refrigerant Pipe
Gas Side 0.D.
In.
1/2
5/8
Liquid Side O.D.
In.
1/4
3/8
Refrigerant Pipe
Length
Height Difference (Max.)
Ft.
100
Length (Max.)
Ft.
100 165
Connection
Method
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
*1. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Out-
door: D.B. 95° F (35° C), W.B. 75° F (24° C).
*2. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Out-
door. D.B. 47° F (8° C), W.B. 43° F (6.1° C).
LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts.
20 A MITSUBISHI ELECTRIC
*3. Rating conditions (heating) -Indoor. D.B. 70° F (21° C), W.B. 60° F (16° C);
Outdoor: D.B. 17° F (-8° C), W.B. 15° F (-9° C).
*4. Indoor units receive power from outdoor units through field -supplied
interconnected wiring.
Specifications are subject to change without notice.
visit www.MitsubishiPro.com
(PEA -A1 8AA- MODEL SHOWN)
BS = Seacoast Protection
PEA/PEAD HEAT PUMP
Model Name
Cooling *1
Indoor Unit
Outdoor Unit
Rated Capacity
Btu/h
PEA-AlBAA4
PUZ-A18NHA4 -BS
18,000
PEAD-A24AA4
PUZ-A24NHA4 -BS
24,000
PEAD-A30AA4
PUZ-A3ONHA4 -BS
30,000
PEAD-A36AA4
PUZ-A36NHA4 -BS
35,000
PEAD-A42AA4
PUZ-A42NHA4 -BS
42,000
Capacity Range
Btu/h
8,000-18,000
12,000-24,000
12,000-30,000
12,000-35,000
18,000-42,000
Total Input
W
2,150
2,400
3,850
4,850
5,350
Energy Efficiency
SEER
14.3
16.0
15.5
15.0
13.8
Moisture Removal
Pints/h
3.26
6.9
8.6
7.9
9.0
Sensible Heat Factor
0.80
0 68
0.75
0.76
Heating at 47° F *2
Rated Capacity
Btu/h
19,000
26,000
32,000
37,000
45,000
Capacity Range
Btu/h
8,000-20,000
12,000-28,000
12,000-34,000
12,000-38,000
18,000-48,000
Total Input
W
1,540
2,250
2,990
3,290
3,820
HSPF (IV)
Btu/h/W
10
10.2
9.4
9.8
10.0
Heating at 17° F'3
Capacity
Btu/h
. 13,000
18,000
23,000
25,000
30,000
Total Input
W
1,520
2,130
2,750
2,810
3,820
Power Supply
Phase, Cycle, Voltage
1 -phase, 60Hz, 208 / 230V'4
Voltage
Indoor - Outdoor S1 - S2
AC208/230V
Indoor - Outdoor S2 - S3
DC24V
Indoor Unit
MCA
A
2
2.63
2.73
3.30
3.50
Fan Motor
F.L.A.
0.74
2.10
2.18
2.64
2.80
Fan Motor Output
W
96
121
244
Airflow (Lo -Mid -Hi)
DRY (CFM)
423-529-635
512-636-742
618-742-883
847-1,024-1,201
1,042-1,254-1,483
WET (CFM)
381-476-572
494-600-671
565-671-812
777-953-1,130
953-1,165-1,412
External Static Pressure
In. WG
0.02
- 0.06 - 0.14 - 0.20
0.14 - 0.20 - 0.28 - 0.40 - 0.60
Sound Pressure Level (Lo -Mid -Hi)
dB(A)
30-34-38
30-33-37 1 30-34-39 33-38-42 1 36-40-44
External Finish Color
Galvanized -steel Sheet
Dimension Unit
W: In.
46-7/8
43-5/16 1 55-1/8
D: In.
27-9/16
28-7/8
H: In.
7-7/8
9-7/8
Weight Unit
Lbs.
62
73 91 1 95
Drain Lift Mechanism (Included)
H: In.
21-11/16
27-9/16
Field Drainpipe Size O.D.
In.
1-1/4
Outdoor Unit
MCA
A
13
18
25 1 26
Recommended Fuse/Breaker Size
A
15
25
30
MOCP
A
20
30
40
Fan Motor
F.L.A.
0.35
0.75
0.4 + 0.4
Fan Motor Output
W
40
75
86 + 86
Compressor
Model Type)
DC INVERTER -driven Twin Rotary
INVERTER -driven Scroll
R.L.A.
12
20
L.R.A.
14 17.5
27.5
Airflow
CFM
1,200 1 1,940
3,530
Refrigerant Control
Linear Expansion Valve
Defrost Method
Reverse Cycle
Sound Pressure Level at•
Cooling *1
d8(A)
48
51
Sound Pressure Level at
Heating *2
d8(A)
47
50
55
External Finish Color
Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In.
31-1/2
37-3/8
D: In.
11-13/16 + 7/8
13 + 1-3/16
H: In.
23-5/8
37-1/8
53-1/8
Weight
Lbs.
91
165
260
Refrigerant
Type
R410A
Charge
Lbs., Oz.
3,12
6,10
10
Oil
Type (fl. oz.)
FV5OS (20)
FV5OS (28)
FV5OS (45)
Refrigerant Pipe
Gas Side O.D.
In.
1/2
5/8
Liquid Side 0.0.
In.
1/4
3/8
Refrigerant Pipe Length
Height Difference (Max.)
Ft.
100
Length (Max.)
Ft.
100 165
Connection Method
Indoor/Outdoor
Flared/Flared
NOTES: Test conditions are based on AHRI 210/240.
I. Rating conditions (cooling) -Indoor. D.B. 80° F (27° C), W.B. 67° F (19° C);
Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C).
*2. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C);
Outdoor. D.B. 47° F (8° C), W.B. 43° F (6.1° C).
LIMITED WARRANTY 1 Seven-year warranty on compressor. Five-year warranty on parts.
*3. Rating conditions (heating) -Indoor. D.B. 70° F (21° C), W.B. 60° F (16° C);
Outdoor: D.B. 17° F (-8° C), W.B. 15° F (-9° C).
"4. Indoor units receive power from outdoor units through field -supplied
interconnected wiring.
Specifications are subject to change without notice.
visit www.MitsubishiPro.com
)MITSUBISHI ELECTRIC 21
PEA/PEAD STATIC PERFORMANCE CURVES
(PEA-A18AA4 MODEL SHOWN)
PEA-Al2AA4
(External Static pressure 0.06 [in.WG]) 208/230V 601-1z
so
[0.20]
40
0.16]
3
30
[0.121
H 20
10.081
10
10.04]
0
(212] (2471 (282) (3181 (3531 1388] 1424]
Airflow nee [CFM(
Limit
*High
\ Middle
•
♦
Nit
Rated point
•
LOW
PEA-Al2AA4
(External static pressure 0.14 [in.WGD 208/230V 60Hz
(0.32]
(028]
g (0.241
5
m (0.20]
[0.161
7. 10.121
10.08]
[0.04]
Lime
R
ted point'
Middle
.`Igh
0
(2121
.0
1247)
12821 131e1
Airflow rate ]CFM]
(353]
(388]
[4 4]
PEA-Al2AA4
(External static pressure 0.20 [in.WG]) 208/230V 60Hz
10.321
[0.28]
(0241
3
$
p [0.20]
a
(0.161
[0.12]
[0.08]
(0.041
0
12 21 12 71 (2821 13 81 [3531
Airflow rate [CFM]
Limh
P
dad point
♦ Migh
•
Middle
Low
•\
[388]
(44]
PEA-A18AA4
(External static pressure 0.06 (in.WG])208/230V 60Hz
(0.20]
1 (0.16]
I [0.12]
(0.08]
[0.04]
Limn
High
.\
MktlI.
Low
Rated
♦
♦
point
\
(3 8] [353] (388] [424] (4591 [494] [530] (565] (600] [636] [671]
AIAIOw rata CFM]
PEA-A18AA4
(External static pressure 0.14 (in.WGD 208/230V 60Hz
[0.32]
(0.20]
[0.24]
3
[0.20]
3
0 [0.16]
w
(0.121
[0.08]
[0.04]
0
[3 8] [353] [388] [424] [4 9] (494] [530] [565] [600] [636] [671]
Arnow rate [CFM]
Limn
Mlgh
Low
10010
\,
\
Rated
point♦
•
PEA-A18AA4
(External static pressure 0.20 [in.WG]) 208/230V 60Hz
[0.32]
[028]
[0.24]
[0.20]
(0.16]
E (0.12]
w
[0.08]
[0.04]
0
[3 8] [353) [388] [424] [4 9] [494] [530] [5651 [600] [636] [671]
Airflow rate ]CFM]
LI mit
M1911
Mlddl
Rated
point
Low
\
\
\,\
\
\
PEAD-A24AA4
(External static pressure 0.20 (in W.G.]) 208-230V 60Hz
5949
04055
0.2011
P.tml
505015
Pawl
ro.0401
PI
Pan
:
Law
fm4
AA,. ma PP4]
Its
PEAD-A24AA4
(Externa( static pressure 0.40 [in W.G.)) 208-230V 60Hz
r a
PI
RSA
Limn 4
i
155
r
5. .
A. .
Prow oein
900) (1061
4.10... ICM
9401
pose!
PEAD-A24AA4
(External static pressure 0.60 [n W.G.() 208.230V 60Hz
I P 005
P70r1
50
p ml
Rath oovn
0055 •
9101 rra01
Aural. ma lone
0005
11588
PEAD-A30AA4
(External static pressure 0.20 [in W.G.( 208-230V 60Hz
03015
pool]
0405]
1
Pmt1
9.5055
0.1281
6401
P0a61
.p.
•
•
1 I
10001 I>005
4vb.mlcsMl
901
PEAD-A30AA4
(External static pressure 0.40 [1n W.G.] 208-230V 60Hz
ro 062
Rana pant
965 pad
100.r rawlcn4
Man
ma]
PEAD-A30AA4
(External static pressure 0.60 [in W.G.( 208-230V 60Hz
05061
it 000•)
1020 1
5005
1008. rm PFlu1
1.101
50
22 AMITSUBISHI ELECTRIC
visit www.MitsubishiPro.cam
PEAD-A36AA4
(External static pressure 0.20 [in W.G.[) 208-230V 60Hz
0./011
0.711
0:011
02311
j5 02411
` 02011
10.1111
0.,231
100101
00101
01
0111
;Mon
t
11x11 11011
0631 110191
011ow 11.01
(CMI
00.2 .2
111891
PEAD-A36AA4
(External static pressure 0.40 [in W.G.[) 208 230V 60Hz
.01i
zfi
2
el 02011
00
0631 11001 11011 11631 110191 11231 11 111 1,101
012.001 !CPA
•
•/'.
•
7!,
'2
•
•
•
4.
PEAD-A36AA4
(External static pressure 0.60 [in W.G.[) 208-230V 60Hz
01011
0011
fi 0.011
02011
01
0101
•
111
.8 •
.
s.
2001) 11631 (10191 110011 11 101 (1000
0232. m. 1x101
PEAD-A42AA4
(External static pressure 0.20 [in W.G.[) 208.230V 60Hz
s
0.1011
103.1
1021,1
102011
02011
p.1111
0.1001
10011
00001
01
1201
•
0201 11o$11 112311 11 10 11110
AMM 123 [CPA]
PEAD-A42AA4
(External static pressure 0.40 in W.G.[) 208-230V 60Hz
102
0.1
1 01911
00011
, /
J
100 0231 110001 110011 I, 111 11101
0low nn ICM1
PEAD-A42AA4
(External static pressure 0.60 1n W.G.[) 208-230V 60Hz
02041
10101
] 0.011
00011
r
•
10001 1,0101 11911 1, 121 11.1
AM. .0 ICM'
Ducting considerations for the PEA/PEAD Horizontal Ducted Indoor Unit
With the introduction of ducted indoor unit products, some information on duct selection and design seems appropriate. Considering the
performance and design of these indoor units, selection, and proper duct sizing and installation are critical elements to consider when de-
signing these indoor units for satisfactory performance and installation.
The maximum available static pressure from the PEA indoor unit is 0.2 in. W.G. and for the PEADs 0.6 in. W.G. Therefore ductless design
is an important element to consider for delivery of proper airflow to a conditioned space. The emphasis should still be on moving refriger-
ant and not air; not only will this dynamic help to work within the static pressure available, but it is also more efficient. Here are some good
practices when ducting the low profile unit:
• When reviewing static pressure duct loss in a system, keep in mind the maximum static pressure the unit will see.
• Flexible duct work, while making installations simpler, can add unnecessary static pressure Toss if not utilized properly. Most of the static
pressure duct loss comes from allowing the duct work to sag. Allowing even a 30 percent sag in the duct work can increase the static
pressure loss up to eight times. Flexible duct work runs should be kept to less than 15 ft. Elbows should be kept to a minimum and
made as wide as possible.
. • Grilles should be selected so that the air velocity is less than 500 ft. per minute, for this prerequisite will help to minimize static
pressure loss.
The chart below shows grille sizes and corresponding flow rates to keep the static pressure loss under 0.05 in.:
Airflow (CFM)
50
100
150
200
250
Grille Size (In. x In.)
6x6
6x6
8x6
10x6, 8x8
12x6, 10x8
• The final component is to understand what the sta is pressure loss
is in the duct work. The chart below shows approx'mate static
pressure loss per 100 ft. for various round duct sizes and flow
rates. If flexible duct work is being used and the flex remains
stretched, 20 percent can be added to the values below to
approximate the loss.
Inches of Static Pressure Loss per 100 ft. of Hard Duct
400
6110
8110
10"o
50 CFM
0.15
0.02
-
-
100 CFM
0.6
0.08
0.02
-
150 CFM
-
0.2
0.04
-
200 CFM
-
0.3
0.08
0.02
250 CFM
-
0.45
0.11
0.04
500 CFM
-
-
0.4
0.15
visit www.MitsubishiPro.com
MITSUBISHI ELECTRIC 23
H2i® P -SERIES
HEAT PUMP
Wall -mounted models
E
Ceiling -cassette models Ceiling -suspended models
BE TAX
CREDIT
rbI
Model Name
Cooling *1
Indoor Unit
Outdoor Unit
Rated Capacity
Btu/h
PKA-A3OKA4
PUZ-HA3ONHA2
30,000
PKA-A36KA4
PUZ-HA36NHA2
33,500
PLA-A3OBA4
PUZ-HA3ONHA2
30,000
PLA-A36BA4
PUZ-HA36NHA2
34,000
PCA-A30KA4
PUZ-HA3ONHA2
30,000
PCA-A36KA4
PUZ-HA36NHA2
34,000
Capacity Range
Btu/h
18,000-30,000
18,000-34,200
18,000-30,000
18,000-36,000
18,000-30,000
18,000-36,000
Total lnput
W
2,500
2,790
2,450
2,690
2,480
2,810
Energy Efficiency
SEER
16.5
16.2
15.6
17
16.1
16.6
Moisture Removal
Pintsrti
8.1
8.7
7.2
7.1
8.3
8.2
Sensible Heat Factor
0.70
0.71
0.73
0.71
0.69
0.73
Heating at 47° F'2
Rated Capacity
Btu/h
32,000
38,000
32,000
38,000
32,000
38,000
Capacity Range
Btu/1i
18,000-34,000
18,000-40,000
18,000-34,000
18,000-40,000
18,000-34,000
18,000-40,000
Total Input
W
2,930
3,410
3,440
3,230
2,990
3,270
HSPF (IV)
Btu/h/W
9.5
10
9.4
10
9.3
10.3
Heating at 17° F'3
Rated Capacity
Btu/h
19,000
25,000
19,000
28,000
19,000
27,000
Rated Total Input •
W
2,570
3,330
2,710
3,590
2,830
3,490
Maximum Capacity
Btu/h
32,000
38,000
32,000
38,000
32,000
38,000
Maximum Total Input
W
5,080
6,010
5,720
5,300
5,170
5,720
Heating at 5° F'4
Maximum Capacity
Btu/1i
32,000
38,000
32,000
38,000
32,000
38,000
Maximum Total Input
W
5,770
6,760
6,630
5,860
5,830
6,550
Power Supply
Phase, Cycle, Voltage
1 -phase, 60Hz, 208/230V *5
Voltage
Indoor - Outdoor S1 - S2
AC208 / 230V
Indoor - Outdoor S2 - S3
DC24V
Indoor Unit
MCA
A
1
2
1
2
Fan Motor
F.L.A.
0.36 1 0.57
0.51
1.00
0.54
0.97
Fan Motor Output
W
56
50
120
95
160
Airflow (Lo -Mid -Hi or Lo-Mid1-
Mid2-H)
DRY (CFM)
635-705-775
705-810-920
490-570-640-740
710-810-920-1,060
565-600-635-705
775-850-920-990
WET (CFM)
570-635-700
635-730-830
460-530-600-710
670-770-880-1,030
530-565-600-670
705-775-850-920
Sound Pressure Level (Lo -Mid -Hi or
Lo-Midi-Mid2-H0
dB(A)
39-42-45
43-46-49
28-30-32-34
32-34-37-40
35-37-39-41
37-39-41-43
External Finish Color
Munsell No. 1 OY 9 2 / 0.2
Munsell No 6 4Y 8.9 / 0 4 (Grille)
Munsell No 6 4Y 8 9 / 0 4
Dimension Unit
W: In.
46-1/16
33-1/16 (Grille: 37-3/8)
50-3/8 63
O: In.
11-5/8
33-1/16 (Grille: 37-3/8)
26-3/4
H: In.
14-3/8
10-3/16 (Grille: 1-3/8)
11-3/4 (Grille 1-3/8)
9-1/16
Weight Unit
Lbs.
46
51 (Grille: 13)
55 (Grille: 13)
71 1 79
Drain Lift Mechanism (Included)
H: In.
N/A
33-7/16
N/A
Field Drainpipe Size
In.
5/8 I.D.
1-1/4 0.D.
1-1/16 0.D.
Outdoor Unit
MCA
A
28
Recommended Fuse/Breaker
A
30
MOCP
A
40
Fan Motor
F.L.A.
0.4 + 0.4
Fan Motor Output
W
60 + 60
Compressor
Model (Type)
INVERTER
R.L.A.
18
L.R.A.
27.5
Airflow
CFM
3,530
Refrigerant Control
Electronic Expansion Valve
Defrost Method
Reverse Cycle
Sound Pressure Level at Cooling *1
dB(A)
52
Sound Pressure Level at Heating *2
dB(A)
53
External Finish Color
Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In.
37-3/8
0: In.
13 + 1-3/16
H: In.
53-1/8
Weight
Lbs.
265
Refrigerant
Type
R410A
Charge
Lbs.
12
Oil
Type (fl. oz.)
FV5OS (45)
Refrigerant Pipe
Gas Side O.D.
In.
5/8
Liquid Side 0.0.
In.
3/8
Refrigerant Pipe Length
Height Difference (Max.)
Ft.
100
Length (Max.)
Ft.
245
Connection Method
Indoor/Outdoor
Flared/Flared
Operating Temperature
Range
Cooling
0° F D.B. to 115° F D.B. with Wind Baffle Accessory Installed
Heating
-13° F W.B. to +59° F W.B.
Notes:
*1. Rating conditions (coo ing)-Indoor: D.B. 26.7° C (80° F),
W.B. 19.4° C (67° F); Outdoor: D.B. 35° C (95° F), W.B. 23.9°
C (75° F).
*2. Rating conditions (heating) -Indoor. D.B. 21.1° C (70° F), W.B.
15.6° C (60° F); Outdoor. D.B. 8.3° C (47° F), W.B. 6.1° C (43° F).
24 ).MITSUBISHI ELECTRIC
*3. Rating conditions (heating) -Indoor: D.B. 21.1° C (70° F),
W.B. 15.6° C (60° F); Outdoor: D.B. -8.3° C (17° F), W.B. -9.4°
C (15° F).
*4. Rating conditions (heating) -Indoor. D.B. 21.1° C (70° F), W.B.
15.6° C (60° F); Outdoor: D.B. -15° C (5° F), W.B. -15° C (5° F).
visit www.MitsubishiPro.com
*5. Indoor units receive power from outdoor units through
field -supplied interconnected wiring.
LIMITED WARRANTY I Seven-year warranty on compressor.
Five-year warranty on parts.
Specifications are subject to change without notice.
H2i° P -SERIES HEAT PUMP
IWIERTfR
Model Name
Indoor Unit
Outdoor Unit
PEAD-A30AA4
PUZ-NA30NHA2
PEAD-A36AA4
PUZ-HA36NHA2
Cooling *1
Rated Capacity
Btu/h
30,000
34,000
Capacity Range
Btu/h
18,000-30,000
18,000-36,000
Total Input
W
2,500
2,800
Energy Efficiency
SEER
16.5
16.8
Moisture Removal
Pints/h
8.9
7.3
Sensible Heat Factor
0.67
0.76
Heating at 47° F'2
Rated Capacity
Btu/h
32,000
38.000
Capacity Range
Btu/h
18,000-34.000
18.000-40,000
Total Input
W
2,750
3,150
HSPF (IV)
Btu/h/W
9.5
10.4
Heating at 17° F'3
Rated Capacity
Btu/h
19,000
27,000
Rated Total Input
W
2,590
3,250
Maximum Capacity
Btu/h
32,000
38,000
Maximum Total Input
W
4,930
5,400
Heating at 5° F'4
Maximum Capacity
Btu/h
32,000
38,000
Maximum Total Input
W
5,420
6,100
Power Supply
Phase, Cycle, Voltage
1 Phase, 60Hz, 208/230V *5
Voltage
Indoor - Outdoor St - S2
AC 208 - 230V
Indoor - Outdoor S2 - S3
DC24V
Indoor - Remote Controller
DC12V: For Wired Controller
Indoor Unit
MCA
A
2.73
3-30
Fan Motor
FLA
2.18
2 64
Fan Motor Output
W
0.121
0.244
Airflow (Lo -Mid -Hi)
DRY (CFM)
618-742-883
847-1,024-1,201
WET (CFM)
565-671-812
777-953-1,130
External Static Pressure *6
In WG
014 - 0 20 - 0 28 - 0.40 - 0 60
Sound Pressure Level (Lo -Mid -Hi)
dB(A)
30-34-39 33-38-42
External Finish Color
Galvanized -steel Sheets
Dimension Unit
W: In.
4.3-5/16 1 55-1/8
D. M.
28-7/8
H In.
9-7/8
Weight Unit
Lbs
73 1 91
Drain Lift Mechanism (Included)
H: In.
27-9/16
Field Drainpipe Size
In
1-1/4
Outdoor Unit
MCA
A
28
Recommended Fuse/Breaker
A
30
MOCP
A
40
Fan Motor
F L.A.
0.4 + 0.4
Fan Motor Output
W
60 + 60
Compressor
Model (Type)
INVERTER -driven Scroll
R.L.A.
18
LRA
27.5
Airflow
CFM
3,530
Refrigerant Control
Electronic Expansion Valve
Defrost Method
Reverse Cycle
Sound Pressure Level at Cooling *1
dB(A)
52
Sound Pressure Level at Heating *2
dB(A)
53
External Finish Color
Munsell No. 3Y 7.8 / 1.1
Dimensions
W: In.
37-3/8
D: In.
13 + 1-3/16'
H: In.
53-1/8
Weight
Lbs.
265
Remote Controller
Type
Wired
Refrigerant
Type
R410A
Charge
Lbs.
12
Oil
Type (fl. oz.)
FV50S (45)
Refrigerant Pipe
Gas Side 0.0.
In.
5/8
Liquid Side 0 D
In
3/8
Refngerant Pipe Length
Height Difference (Max)
Ft
100
Length (Max.)
Ft
245
Connection Method
Indoor/Outdoor
Flared/Flared
Operating Temperature
Range
Cooling
0° F D.B. to 115° F with Wind Baffle
Accessory Installed
Heating
-13° F W.B to +59° F W.B.
Notes:
1. Rating conditions (cooling) -Indoor: D.B. 26.7° C (80° F), W.B.
19.4° C (67° F); Outdoor. D.B. 35° C (95° F), W.B. 23.9° C (75° F).
*2. Rating conditions (heating) -Indoor: D.B. 21.1° C (70° F), W.B.
15.6° C (60° F); Outdoor: D.B. 8.3° C (47° F►, W.B. 6.1° C (43° F).
Horizontal ducted models
"3. Rating conditions (heating) -Indoor. D.B. 21. ° C (70° F),
W.B. 15.6° C (60° F); Outdoor: D.B. -8.3° C ( 7° F),
W.B. -9.4° C (15° F).
*4'. Rating conditions (heating) -Indoor. D.B. 21.1° C (70° F), W.B.
15.6° C (60° F); Outdoor. D.B. -15° C (5° F), W.B. -15° C (5° F).
visit www.MitsubishiPro.com
"5. Indoor units receive power from outdoor units through
field -supplied interconnected wiring.
*6. External static pressure Is factory set to 0.20° WG.
LIMITED WARRANTY I Seven-year warranty an compressor.
Rve-year warranty on parts.
%MITSUBISHI ELECTRIC 25
CONTROLLERS
MHK1 Remote Controller Kit
Exclusive for INVERTER -driven Mr. Slim® Systems
MRCH1 WIRELESS REMOTE CONTROLLER
• Features backlit, easy -to -read display
• Is compatible with MCCH1
Portable Central Controller
• Is enabled with RedLINKTM reliability
MFH1 WIRELESS RECEIVER
• Required for MRCH1 Wireless
Remote Controller
• Incorporates ual setpoint control with system
changeover
• Enabled with RedLINK reliability
Wireless Technology
Wireless Remote Controller
Wireless Receiver
Function
ON/OFF
Description
ON/OFF operation for a single indoor unit
Operation Mode
Cool / Drying / Auto / Heat / Fan only
Available operation modes dependent on connected system.
Temperature Setting
Set temperature from 50° F - 87° F depending on operation mode and
connected system
System Changeover Deadband Value
2-8° F
Schedule Operation
5-2, 5-1-1
Fan Speed Setting
Hi/Mid-2/Mid-1/Low/Auto
Available fan speed settings dependent on connected system.
Airflow Direction Setting
Airflow angles: 100° - 80° - 60° - 40° and oscillate
Available airflow direction settings dependent on connected system.
Permit/Prohibit Function
Individual prohibit operations for each remote controller function
(ON/OFF, Set Temperature, and Operation Mode).
Space Temperature
Displays the measured space temperature.
Error Indication
Displays error code.
Display Outside Temperature
and Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - (W x D x H)
Remote Controller: 5-3/16" x 1-1/2" x 3-9/16"
Receiver: 3-1/4" x 1-5/16" x 6-7/16"
Operating Ambient Temperature
Remote Controller: 32 - 120° F
Receiver: -40 - 165° F
Operating Ambient Humidity
Remote Controller: 5% - 90% RH (non -condensing)
Receiver: 5% - 9% RH (non -condensing)
Power Supply
2 AA batteries
MHK1 Kit includes
MRCH1 Wireless Wall -Mounted Remote Controllers
MFH1 Wireless Receiver and Cable
MRC1 Cable
Install and Operation Manual
26 :MITSUBISHI ELECTRIC
Accessories
MCCH1 Portable Central Controllers
MOS1 Outside Air Sensor
visit www.MitsubishiPro.com
CONTROLLERS
MCCH1 Portable Central Controller
Exclusive for INVERTER -driven Mr. Slim® Systems
• Has up to 16 Zones
• Works with MRCH1 Wireless Remote Controller
• Is able to monitor and control ON/OFF, Mode, Set Temperature
• Enables schedule overrides
• Can view Outside Aair temperature and humidity with optional
MOS1 Outside Air Sensor
• Features backlit easy -to -read display
• Is compatible with other RedLINKTM devices
• Does not interfere with other wireless devices
4))
Wireless Technology
Function
ON/OFF
Description
Offers ON/OFF operation for up to 16 individual indoor units
Operation Mode
Cool / Auto / Heat
Offers available operation modes dependent on connected system
Temperature Setting
Has capability to set temperature from 50° F — 87° F depending on operation
mode and connected system
Space Temperature
Displays the measured space temperature individually per indoor unit
Error Indication
Displays error code
Display Outside Temperature and
Humidity
Requires optional MOS1 Outside Air Sensor
Dimensions - (W x D x H)
3-1/8" x 1-5/8" x 6-1/4"
Operating Ambient Temperature
32 - 120° F
Operating Ambient Humidity
5% - 90% RH (non -condensing)
Power Supply
3 AA batteries
Requires MHK1 (Remote Controller and Receiver) per indoor unit.
Accessories
MOS1 Outside Air Sensor
visit www.MitsubishiPro.com .:MITSUBISHI ELECTRIC 27
CO\TROLLFRS
Set Temperature
Timer Menu
Mode
Set Time
PAR -21 MAA Wired Controller
Timer ON/OFF—
Wired controller for the
indoor unit. (multi-lingual)
ON/OFF
Fan Speed
Filter
Test Run
Check
Airflow UP/DOWN
Louver
Ventilation
Function
ON/OFF
Description
ON/OFF operation for group of up to 16 indoor units
Operation Mode
Cool / Dry / Auto / Heat / Fan only
Available operation modes dependent on connected system
Temperature Setting
Set temperature from 50° F — 87° F depending on operation mode and
connected system
Timer Operation
7 day timer (ON/OFF, Set Temperature)
Fan Speed Setting
Hi/Mid-2/Mid-1/Low/Auto
Available fan speed settings dependent on connected system
Airflow Direction Setting
Airflow angles: 100° - 80° - 60° - 40° and oscillate
Available airflow direction settings dependent on connected system
Permit/Prohibit Function
Individual prohibit operations for each remote controller function
(ON/OFF, Set Temperature, Operation Mode, and Filter reset)
Space Temperature
Measured space temperature displayed
Error Indication
Error code displayed
Dimensions - (W x D x H)
5-1/8" x 3/4" x 4-3/4"
28 ..MITSUBISHI ELECTRIC visit www.MitsubishiPro.com
CONT
ROLLERS
Hand-held IR Wireless Controller
Function
ON/OFF
Description
ON/OFF operation for a single indoor unit
Operation Mode
Cool / Dry / Auto / Heat / Fan only
Available operation modes dependent on connected system.
Temperature Setting
Set temperature from 50° F, — 87° F depending on operation mode and
connected system
Timer Operation
ON/OFF timer
Fan Speed Setting
Hi/Mid-2/Mid-1/Low/Auto
Available fan speed settings dependent on connected system.
Airflow Direction Setting
Airflow angles: 100° - 80° - 60° - 40° and oscillate
Available airflow direction settings dependent on connected system.
Permit/Prohibit Function
Individual prohibit operations for each remote controller function
(ON/OFF, Set Temperature, Operation Mode, and Filter reset).
Space Temperature
Displays the measured space temperature.
Dimensions - (W x D x H)
5-1/8" x 3/4" x 4-3/4"
Power Supply
2 AAA batteries
visit www.MitsubishiPro.com AMITSUBISHI ELECTRIC 29
iFMT
H2I P -SERIES (PUZ-HA-2) OPERATING CONDITIONS
COOLING
HEATING
MAXIMUM
MINIMUM
MAXIMUM
MINIMUM
INDOOR INTAKE
AIR TEMPERATURE
90° F D.B., 73° F W.B.
66° F D.B., 59° F W.B.
83° F D.B.
63° F D.B.
OUTDOOR INTAKE AIR
TEMPERATURE
115° F D.B.
0° F D.B.*
70° F D.B., 59° F W.B.
-13° F D.B., -13° F W.B.
With wind baffle accessary installed. Without wind baffle Installed, the minimum temperature will be 23° F D.B.
P -SERIES (PUY/PUZ-4) OPERATING CONDITIONS
COOLING
HEATING
MAXIMUM
MINIMUM
MAXIMUM
MINIMUM
INDOOR INTAKE AIR
TEMPERATURE
95° F D.B., 71° F W.B.
67° F D.B., 57° F W.B.
80° F D.B., 67° F W.B. (PUZ-A)
70° F D.B., 60° F W.B. (PUZ-A)
OUTDOOR INTAKE AIR
TEMPERATURE
115°FD.B.
0° F D.B.*
70° F D.B., 59° F W.B. (PUZ-A)
12° F D.B., 10° F W.B. (PUZ-A)
With wind baffle accessory installed. Without wind baffle Installed, the minimum temperature will be 23° F D.B.
REFRIGERANT TUBING SETS
Lineset
Model Number
MLS141212T-15
MLS141212T-30
MLS141212T-50
MLS141212T-65
MLS141212-100
MPLS385812T-10
MPLS385812T-15
MPLS385812T-30
MPLS385812T-50
MPLS385812T-65
MPLS385812T-100
Tube Length Insul.
Size (In.) Ft.
URI MEI
EEO
LSI
111151
®®
111131
Ell
1/4 x 1/2
1/4 x 1/2
30
1/4 x 1/2
50
1/4 x 1/2
65
1/4 x 1/2
100
3/8 x 5/8
3/8 x 5/8
3/8 x 5/8
10
30
3/8 x 5/8
50
3/8 x 5/8
65
3/8 x 5/8
100
Use With Mitsubishi
Electric Models
PKA-Al2,18HA4;
PLA-Al2,18BA4; PEA-Al2,
Al 8AA4
PKA-A24,30,36KA4;
PLA-A24,30,36,42BA4;
PCA-A24,30,36,42KA4;
PEAD-A24-42AA4
OPTIONAL ACCESSORIES
REFRIGERANT LINE LENGTH FLARE/FLARE
INDOOR UNIT
PKA-Al2HA4
OUTDOOR UNIT
PUY-Al2NHA4
LENGTH
IN FEET
100
HEIGHT
IN FEET
100
PKA-A18HA4
PUY/Z-A18NHA4
100
100
PKA-A24KA4
PUY/Z-A24NHA4
165
100
PKA-A3OKA4
PUY/Z-A3ONHA4
165
100
PKA-A3OKA(H2)
PUZ-HA3ONHA2
245
100
PKA-A36KA4
PUY/Z-A36NHA4
165
100
PKA-A36KA (H2i)
PUZ-HA36NHA2
245
100
PLA-Al2BA4
PUY-Al2NHA4
100
100
PLA-A18BA4
PUY/Z-A18NHA4
100
100
PLA-A24BA4
PUY/Z-A24NHA4
165
100
PLA-A3OBA4
PUY/Z-A3ONHA4
165
100
PLA-A3OBA (H2i)
PUZ-HA3ONHA2
245
100
PLA-A36BA4
PUY2-A36NHA4
165
100
PIA-A36BA (H2i)
PUZ-HA36NHA2
245
100
PLA-A42BA4
PUY/Z-A42NHA4
165
100
PCA-A24KA4
PUY/Z-A24NHA4
165
100
PCA-A3OKA4
PUY/Z-A3ONHA4
165
100
PCA-A30KA(H2i)
PUZ-HA3ONHA2
245
100
PCA-A36KA4
PUY/Z-A36NHA4
165
100
PCA-A36KA (H2i)
PUZ-HA36NHA2
245
100 •
PCA-A42KA4
PUY/Z-A42NHA4
165
100
PEA-Al2AA4
PUY-Al2NHA4
100
100
PEA-A18AA4
PUY/Z-A18NHA4
100
100
(2)PEA-A18AA (1-121)
PUY/Z-HA36NHA2
245
100
PEAD-A24AA4
PUY/Z-A24NHA4
165
100
PEAD-A30AA4
PUY2-A3ONHA4
165
100
PEAD-A30AA(H2)
PUZ-HA3ONHA2
245
100
PEAD-A36AA4
PUY/Z-A36NHA4
165
100
PEAD-A36AA (H2i)
PUZ-HA36NHA2
245
100
PEAD-A42AA4
PUY/Z-A42NHA4
165
100
PART NUMBER
PAC-SH84DM-E
USE WITH
PCA-A**KA
DESCRIPTION
Pum ' s
Mitsubishi pump kit
SI1730-230
P -Series - 30,000 Btu/11 or greater
Sauermann® mini condensation pump: 230V
SI3100-230
P -Series - Less than 30,000 Btu/h
Sauermann® mini condensation pump: 230V
Miscellaneous
BRP -1
Bottom Return Plate for SEZ-KD09NA
Converts low profile ducted indoor unit from rear retum to bottom return
BRP -2
Bottom Return Plate for PEA-Al2AA
Converts low profile ducted indoor unit from rear return to bottom return
BRP -3
Bottom Return Plate for PEA -A1 8AA
Converts low profile ducted indoor unit from rear return to bottom return
BV12FSI
Use with any Mr. Slim multi -zone product
Refrigeration Ball Valve-Flare/Schrader®/Insulated -1/2"
BV14FSI
Use with any Mr. Slim multi -zone product
Refrigeration Ball Valve-Flare/Schrader®/Insulated -1/4"
BV38FSI
Use with any Mr. Slim multi -zone product
Refrigeration Ball Valve-Flare/Schrader®/Insulated - 3/8"
BV58FSI
Use with any Mr. Slim multi -zone product
Refrigeration Ball Valve-Flare/Schrader®/Insulated - 5/8"
CWMB1
PU outdoor units
Condensing unit wall mounting brackets (set of 2) - 440 Ib. capacity: painted steel
NOTE: Installer is responsible to select and provide suitable hardware and materials to insure proper
mount of bracket to wall.
DSD -400N
P -Series
DiamondBackTM Platform Stands
PAC-SG58SG-E
P -Series
Air outlet guide (1 piece) PUY/Z-Al2/A18
PAC SG59SG E
P -Series
Air outlet guide (1 piece) PUY/Z-A24/A30/A36/A42 (42 installation requires 2 pieces); PUZ-HA36NA
(Requires 2 pieces)
PAC-SG61DS-E
PUZ(Y)-A42
Drain socket -connector
PAC-SG63DP-E
PUZ(Y)-Al2/18
Drain pan
PAC-SG64DP-E
PUZ(Y)-A24/30/36/42 / PUZ-HA36
Drain pan
PAC-SH51 SP -E
All PLA -ABA Models
Air outlet shutter plates (1 set = 2 pieces)
PAC-SH53TM-E
All PLA -ABA Models
Multi -function casement (High -efficiency filter element not included)
RCMKP1 CB
P -Series Wireless
Lockdown bracket for remote controller
ULTRILITE1
PUZ(Y)-Al2/18
Condensing unit mounting pad: 16" x 36" x 3"
ULTRILITE2
PUZ(Y)-A24/30/36/42; PUZ-HA30, 36
Condensing unit mounting pad: 24" x 42" x 3"
30 AMITSUBISHI ELECTRIC
*49' and 66' applies to installations In which the outdoor unit is installed below Indoor unit
visit www.MitsubishiPro.com
OPTIONAL ACCESSORIES (CONT.)
PART NUMBER
USE WITH DESCRIPTION
MSDD-50SR-E
Port Adapters
P -Series
and Connection Pipes
Twinning distribution pipe
PAC-SC84PI-E
PKA-Series (A24/30/36/42)
L connector pipe (for left side piping)
Control
Options and Accessories
CN24RELAY-KIT-CM3
PLA -BA, PCA -KA, PEA -AA indoor units
External heater relay kit and adapter for CN24 connector and control
PAC-715AD
P -Series
Connector for CN32 (for remote on/off)
PAC 725AD
P -Series / PKA-HAIL)/KA(L) indoor units
Connector for CN51/multiple remote controller adapter - status/signal output and duct/supply fan
controller (PLA/PCA), External Heater Control for CN152
PAC-SA1 ME -E
i -see"' sensor for PLA -ABA
i -see sensor corner panel for PLA -ABA indoor units
PAC-SE41 TS -E
P -Series indoor units
Remote temperature sensor for P -Series indoor units
PAC-SE55RA-E
P -Series
Remote operation adapter: CN32 Remote on/off
PAC-SE57RA-E
PLA / PKA / PCA
Remote operation adapter: CN30 LLC
PAC-SE59RA-E
P -Series
Remote operation adapter: display and OWOFF
PAC-SF4ORM-E
P -Series
Remote operation adapter: display and on/off
PAC-SF81 MA -E
PUY-A, PUZ-A, and PUZ-HA
M -NET control adapter for Mr. Slim PUY-A, PUZ-A, and PUZ-HA outdoor units
PAC-SH91 MK -E
i -see sensor for PCA
i -see sensor in mounting panel for PCA indoor units
PAC-SK52ST
P -Series Service Tool
Control / Service tool w/display for P -Series systems - Connects to outdoor unit •
PAC-YU25HT
PEA, PEAD indoor units
External fan / Heater control relay adapter
PAR -21 MAA -G
Use with P -Series
Deluxe MA remote controller (Requires MAC -3971F -E for use with M -Series - MSY/Z, MFZ)
MHK1
All P -Series and SEZ, SLZ 1:1 Systems
RedLINKTM Enabled Remote Controller Kit with MRCH1 controller, MIFH1 receiver, and MRC1 cable
MCCH1
MHK1
Portable central controller; works with MHK1
PAR-FL32MA
PLA / PEA / PEAD / SEZ
Wireless remote controller for PLA -BA, PEA -A, PEAD-AA units (Requires signal receiver PAR-SA9FA-
E)
PAR-SA9CA-E
PEA, PEAD and PKA
Wireless signal receiver for PEA, PEAD, and PKA units (For PAR-SL32MA controller)
PAR-SA9FA-E
PLA -ABA
Wireless signal receiver for PLA -BA units (For PAR-SL32MA controller)
PAR-SA92MW-E
PCA wireless controller kit with i -see sensor
Wireless remote controller kit with i -see sensor for PCA
PAR-SL93B-E
PCA Wireless controller kit
Wireless remote controller kit for PCA
PZ -41 SLB -E
Lossnay
Lossnay ERV remote controller for LGH ERV control
RG78G358G18
PKA (L) models
Connector for CN -22 to add wired controller - PAR -21 MAA -G to PKA(L) wireless models
Low Ambient
WB-PA1
P -Series
Wind baffle (1 piece) PUY/Z-Al2/A18
WB-PA2
P Series
Wind baffle (1 piece) PUY/Z-A24/A30/A36/A42 (42 installation requires 2 pieces); PUZ-HA30
and 36NA (Requires 2 pieces)
visit www.MitsubishiPro.com AMITSUBISHI ELECTRIC 31
DIAMONDBACK'
Ball Valves
Model numbers:
BV14FFSI
BV38FFSI
BV12FFSI
BV58FFSI
c
us
LISTED 891N
REFRIGERANT
VALVE
• Sizes available: 1/4"; 3/8"; 1/2"; 5/8"
• Fully factory assembled
• Furnace brazed and pressure tested
• Each ball valve is equipped with Schrader® valve
for refrigerant service
• Design working pressure: 700 PSIG
• Temperature range:
-40° F to +325° F (-40° C to +149° C)
• Forged brass body andseal cap
• Polytetrafluroethylene seals and gaskets
(no synthetic O -rings)
• Seal cap design permits valve operation without
removal of seal cap
• Uses suitable for with R-11, R-22, R-123, R-125,
R -134A, R-236FA, R -4202A, R -402B, R -404A,
R -407C, R -410A, R-500, R-502, and R-507
• One year limited materials and workmanship
warranty on ball valves
Teflon® is a registered trademark of E.I. du Pont de Nemours and Company
Schrader® is a registered trademark of Schrader — Bridgeport Inc.
• Engineered for Mini -split and
Multi -split HVAC Units
• Full Port Design
• 700 PSIG Rated
• R -410A Compatible
• Flare Connections
Part Number
SAE
Flare
A
BCD
E
F
BV14FFSI
1/4"
6.19
2.60
1.80
1.22
1.42
1.10
BV38FFSI
3/8"
6.30
2.67
1.80
1.22
1.42
1.10
BV12FFSI
1/2"
6.51
2.67
1.80
1.22
1.42.
1.10
BV58FFSI
5/8"
6.64
2.67
1.80
1.28
1.42
1.10
'Ballvalves come with an insulation piece
� L
32 ..MITSUBISHI ELECTRIC
DIAMONDBACK"
(gg Platform Stands
Lift the Mitsubishi Electric Comfort Solution
outdoor unit to new heights with our
Diamondback Platform Stands.
• Is easy to install
• Available for all sizes of Mr. Slim outdoor units
• Is color matched to the outdoor units
Model Number: DSD -400N
L: 15-3/4" x W: 3-1/4" x H: 3-1/4"
visit www.MitsubishiPro.com
DIAMONDBACK'"' LINESET
(+
Caps on
Caps off with
flared ends
exposed
I
00
Lineset
Model Number
MLS141212T-30
Tube
Size (In.)
1/4 x 1/2
Length
Ft.
30
Insul.
1/2"
MLS141212T-50
1/4 x 1/2
50
1/2"
MLS141212T-65
1/4 x 1/2
65
1/2"
MLS141212T-100
1/4 x 1/2
100
1/2"
MLS145812T-15
1/4 x 5/8
15
1/2"
MLS145812T-30
1/4 x 5/8
30
1/2"
MLS145812T-50
1/4 x 5/8
50
1/2"
MLS145812T-65
1/4 x 5/8
65
1/2"
MLS145812T-100
1/4 x 5/8
100
1/2"
MPLS385812T-10
3/8 x 5/8
10
1/2"
MPLS385812T-15
3/8 x 5/8
15
1/2"
MPLS385812T-30
3/8 x 5/8
30
1/2"
AMPLS385812T-50
3/8 x 5/8
50
1/2"
MPLS385812T-65
3/8 x 5/8
65
1/2"
MPLS385812T-100
3/8 x 5/8
100
1/2"
Diamondback advantages include the following features:
• Quick, efficient, and economical field installation using factory -applied
Twin Tube insulation and flare connections with flare nuts mounted
• Correct lengths for reducing waste and time
• Quality, consistency, and economy
• Testing of all Diamondback Lineset tubing is tested in accordance
with ASTM E243
Twin -Tube Lineset Insulation Design
• Balanced outside diameter for uniform coil/uncoil
position stability
• Minimum 1/2" insulation thickness on both tubes
Filter Boxes
FB Series filter boxes are available in compatible sizes for all
Mr. Slim horizontal ducted indoor units.
FBL1 filter boxes include 1" thick -pleated MERV 8 filter(s), and
FBM2 boxes include 2" thick -pleated MERV 13 filter(s) installed.
Filters are tested in accordance with ANSI/ASHRAE Standard 52.2
and rated Class 2 under U.L. Standard 900.
FBL1-1
FB Series Filter Box for SEZ-KDO9N
FBL1-2
FB Series Filter Box for SEZ-KD12,KD15-NA,
and PEA-Al2AA
FBL1-3
FB Series Filter Box for SEZ-KD18NA and PEA-A18M
FBM2-3
FB Series Filter Box for PEAD-A24,30AA
FBM2-4
FB Series Filter Box for PEAD-A36,42AA
The cabinet is constructed of non -insulated 20 gauge G-60 galvanized steel with foam gasket and provides
an airtight connection to indoor unit and access door. Gasket material complies with UL 723 requirements.
A screw -through cabinet design for secure attachment to indoor unit and return connection in rear is easily
field -converted to bottom return.
visit www.MitsubishiPro.com AMITSUBISHI ELECTRIC 33
Put a professional finish on air-conditioning
installations with an easy -to -install modular
system that beautifies exteriors and protects
linesets, drainlines, and wiring.
• Can be used indoors, too! Meets UL94v-0
for interior applications
• Has snap -on covers and a full selection of
couplings, elbows, T -joints, caps, and more
for any application: complex or simple
• Offers high-quality PVC with UV inhibitors
for outdoor service in all weather conditions
• Can be painted with most house paints to
match exterior decors
• Is not just for HVAC. Hides any exterior
cabling, piping, or wiring
• Is available in four sizes: 2-1/4", 3", 4",
and 6" tubes
Download a brochure at www.line-hide.com to find
out more information.
AMrrsusi l ELEC RIC
Model
CFM
Model
CFM
LGH-F300RX3-E
300
LGH-F470RX3-E
470
LGH-F600RX3-E
600
LGH-F1200RX3-E
1,200
Improved sound attenuation makes Lossnay®
units quiet enough for places where silence is
a must such as meeting rooms and libraries. A
free -cooling function is standard to help reduce
costs and boost efficiency. The integrated
bypass damper design makes installation
and system management quick and efficient.
Lossnay models offer three ventilation modes:
• Energy Recovery - Heat Exchange
• Bypass - No Exchange
• Automatic - Heat Exchange/Bypass
34 :.MITSUBISHI ELECTRIC visit www.MitsubishiPro.com
M -SERIES
1NVERTER-d riven
• MITSUBISHI
M ELECTRIC
i..t<44,',3 ON: $1,10114 504.0gorg
CITY MULTI®
Variable Refrigerant Flow
• MITSUBISHI
4/111ELECTRIC
Cj4J qrly
INVERTER-dnven
Split -Ductless Comfort Systems
M- Series Full Line Catalog
For more information on our
INVERTER -driven product line visit our
website at www.mitsubishipro.com
Variable Refrigerant Flow
Zoning Systems: 3-30 Tons
For more information on our CITY MULTI VRF product line visit
our website at www.mitsubishipro.com
visit www.MitsubishiPro.com ...MITSUBISHI ELECTRIC 35
COOLING & HEATING
Mitsubishi Electric Advanced Products Division
3400 Lawrenceville Suwanee Road, Suwanee, GA 30024
Phone: 888-467-7546 Fax: 800-658-1458
M2011 Mitsubishi Electric & Electronics USA, Inc. Mr Slim and H2i are registered
tradernarks of Mitsubishi Electric. The three -diamond logo is a registered logo of
Mitsubishi Electric Corporation.
'Hyper -Heating technology Patent Pending.
RedLINK and RedLINK wireless technology logo are a registered trademark of
Honeywell International
See complete warranty for terms, conditions, and limitations.
A copy is available from Mitsubishi Electric_
FormNo. PSERIES 5-11 40K OA (reprint)
For more information visit www.mitsubishipro.com
Mixed Sources
(A �i CERTIFIED,.
P:rdut group from well-managed
fri esis .and c cher controlled sources
FSC
ENERGY STAR
PARTNER
facebook.com/mehvac twitter.com/m€tsub€sh€hvac You Tube youtube.com/mitsubishihvac
Please Recycle
MIT OP,F3D
PLAN REVIEW/ROUTING SLIP
ACTIVITY NUMBER: M13-110 DATE: 06/18/13
PROJECT NAME: CASCADE VIEW ELEMENTARY
SITE ADDRESS: 13601 32 AV S
X Original Plan Submittal Response to Incomplete Letter #
Response to Correction Letter #
Revision # after Permit Issued
DEPARTMENTS:
b1-- J Al
Building Division
Public Works
Awe
Fire Previon
Structural
Planning Division
❑ Permit Coordinator ❑
DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 06/20/13
Complete tg]
Incomplete ❑
Not Applicable ❑
Comments:
Permit Center Use Only
INCOMPLETE LETTER MAILED:
LETTER OF COMPLETENESS MAILED:
Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
TUESITHURS ROUTING:
Please Routet5-41 Structural Review Required ❑ No further Review Required ❑
REVIEWER'S INITIALS: DATE:
APPROVALS OR CORRECTIONS:
DUE DATE: 07/18/13
Approved ❑ Approved with Conditions k Not Approved (attach comments) ❑
Notation:
REVIEWER'S INITIALS:
DATE:
Permit Center Use Only
CORRECTION LETTER MAILED:
Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials:
Contractors or Tradespeople Prater Friendly Page
•
General/Specialty Contractor
A business registered as a construction contractor with LaI to perform construction work within the scope of
its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of
account and carry general liability insurance.
Business and Licensing Information
Name MCKINSTRY CO LLC UBI No. 602569922
Phone 2067623311 Status Active
Address Po Box 24567 License No. MCKINCL942DW
Suite/Apt. License Type Construction Contractor
City Seattle Effective Date 3/16/2006
State WA Expiration Date 3/16/2014
Zip 98134 Suspend Date
County King Specialty 1 General
Business Type Limited Liability Company Specialty 2 Unused
Parent Company
Other Associated Licenses
License
Name
Type
Specialty
1
Specialty
2
Effective
Date
Expiration
Date
Status
LYDIGML901JLLYDIG+
MCKINSTRY LLC
Construction
Contractor
General
Unused
4/13/2010
4/13/2014
Active
WESTVI'121RF
WESTVENT INC
Construction
Contractor
General
Unused
12/6/1988
9/1/1994
Archived
MCKIN**372ND
MCKINSTRY CO
Construction
Contractor
General
Unused
8/20/1963
1/2/2008
Re
Licensed
Business Owner Information
Name
Role
Effective Date
Expiration Date
PEDERSEN, JAMIE D
Agent
03/16/2006
Bond Amount
ALLEN, DEAN CHARLES
Partner/Member
03/16/2006
929519469
MOORE, DOUGLAS JAMES
Partner/Member
03/16/2006
ALLEN, DAVID EDWARD
Partner/Member
03/16/2006
WESTERN SURETY CO
TEPLICKY, JOSEPH WILLIAM
Partner/Member
03/16/2006
Bond Information
Page 1 of 2
Bond
Bond Company Name
Bond Account Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Bond Amount
Received Date
3
Western Surety Co
929519469
03/01/2011
Until Cancelled
01/23/2012
$12,000.00
02/24/2011
2
WESTERN SURETY CO
929511574
09/09/2010
Until Cancelled
$12,000.00
09/02/2010
1
TRAVELERS CAS &
SURETY CO
104702039
01/03/2006
Until Cancelled
03/01/2011
$12,000.00
03/16/2006
Assignment of Savings Information No records found for the previous 6 year period
Insurance Information
Insurance
Company Name
Policy Number
Effective Date
Expiration Date
Cancel Date
Impaired Date
Amount
Received Date
6
Zurich
American Ins Co
GLA 3999903
01/31/2013
01/31/2014
$2,000,000.00
01/02/2013
5
Zurich
American Ins Co
GLA 3999903
01/31/2012
01/31/2013
$2,000,000.00
12/16/2011
4
ZURICH
AMERICAN INS
CO
GLA3999903
01/31/2011
01/31/2012
$2,000,000.0012/20/2010
3
ZURICH
AMERICAN INS
CO
CP0399990301
01/31/2009
01/31/2011
$2,000,000.00
12/07/2009
2
CP03999903
01/31/2008
01/31/2009
$2,000,000.00
01/31/2008
httns://fortress.wa.gov/lni/bbip/Print.aspx
06/27/2013