Loading...
HomeMy WebLinkAboutPermit M13-110 - CASCADE VIEW ELEMENTARY - ALTERATIONCASCADE VIEW ELEMENTARY 13601 32 AV S M13-110 City ofukwila �J qs Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 1623049038 Address: 13601 32 AV S TUKW Project Name: CASCADE VIEW ELEMENTARY MECHANICAL PERMIT Permit Number: M13-110 Issue Date: 06/27/2013 Permit Expires On: 12/24/2013 Owner: Name: TUKWILA SCHOOL DISTRICT Address: 4640 S 144TH ST , TUKWILA WA 98168 Contact Person: Name: LARRY MAYOTTE Address: 5005 3 AV , SEATTLE WA 98134 Email: LARYMA@MCKINSTRY.COM Contractor: Name: MCKINSTRY CO LLC Address: PO BOX 24567 , SEATTLE WA 98124 Contractor License No: MCKINCL942DW Phone: 206 200-8871 Phone: 206 762-3311 Expiration Date: 03/16/2014 DESCRIPTION OF WORK: REPLACEMENT OF 1.5 TON (18,000 BTU) COOLING ONLY MINI -SPLIT SYSTEM TO CONDITION IDF DATA CLOSET. CONDENSING UNIT IS ROOF MOUNTED AND EVAPORATOR IS WALL MOUNTED IN THE DATA CLOSET. Value of Mechanical: $6,762.00 Type of Fire Protection: SPR]NKLERS/AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $269.31 International Mechanical Code Edition: 2009 Date: dko/ 2K? I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Date: 6/21/13 Print Name: LAagy `I/tA'/o tiir This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. n..:..a..d. nc n-7 nni PERMIT CONDITIONS Permit No. M13-110 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. doc: IMC -4/10 M13-110 Printed: 06-27-2013 CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. t?j , t Project No. Date Application Accepted: (k)I � I Date Application Expires: 11 (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION;'' King Co Assessor's Tax No.: Site Address: 13601 32nd Avenue South Suite Number: Floor: It0230490 3a Tenant Name: Cascade View Elementary School PROPERTY OWNER Name: Larry Mayotte Name: Tukwila School District Address: 5005 3rd Ave Address: 4640 S 144th Street City: Seattle State: Wa City: Tukwila State: Wa Zip: 98168 CONTACT PERSON — person receiving all project communication Name: Larry Mayotte Address: 5005 3rd Ave Address: 5005 3rd Ave Phone: (206) 200-8871 Fax: (253) 272-1714 City: Seattle State: Wa Zip: 98134 Phone: (206) 200-8871 Fax: (253) 272-1714 Email: larryma@mckinstry.com New Tenant: ❑ Yes ® ..No MECHANICAL CONTRACTOR LNFORMATION Company Name: McKinstry Address: 5005 3rd Ave City: Seattle State: Wa Zip: 98134 Phone: (206) 200-8871 Fax: (253) 272-1714 Contr Reg No.:MCKINCL942DW Exp Date: 03/16/2014 Tukwila Business License No.: ',0s — 010i 413 Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Replacement of 1.5 (18,000 BTU) Ton Cooling only mini -split system to condition IDF Data Closet. Condensing unit is roof mounted and evaporator is wall mounted in the data closet. 6,762 Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement m Fuel Type: Electric Gas ❑ Other: H:\Applications\Forms-Applications On Line \2011 ApplicationsN9echanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 • Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/walUfloor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system 1 Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial 1 Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one.extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNERDR AUTHORIZED AGENT: Signature: CA. / Date: 06/14/2013 Print Name: Larry Mayotte Day Telephone: (206) 200-8871 Mailing Address: 5005 3rd Ave Seattle Wa 98134 City State Zip H:\Applicaiions\Fotms-Applications On Line 2011 Applications'Mechanical Permit Application Revised 8.9.11.docx Revised: August 2011 bh Page 2 of 2 • • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov Parcel No.: 1623049038 Address: 13601 32 AV S TUKW Suite No: Applicant: CASCADE VIEW ELEMENTARY RECEIPT Permit Number: M13-110 Status: PENDING Applied Date: 06/18/2013 Issue Date: Receipt No.: R13-01903 Payment Amount: $269.31 Initials: JEM Payment Date: 06/18/2013 11:02 AM User ID: 1165 Balance: $0.00 Payee: LAWRENCE A MAYOTTE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 04597C ACCOUNT ITEM LIST: Description 269.31 Account Code Current Pmts MECHANICAL - NONRES PLAN CHECK - NONRES 000.322.102.00.00 215.45 000.345.830 53.86 Total: $269.31 Drin*n.1• !1R_'IA_')l11Z INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 rnil3-11 0 Project: - C' FISC A sem. V I f J Type of Inspection: ,- 11•.i icl L__ Address: t-3vo t 32_ no <- Date Called: Special Instructions: Date Wanted: n_ n a.rrl Requester: Phone No: )(T)6, - 2S -S Li30 S ,Approved: per applicable codes. COMMENTS:, Corrections required prior to approval. Date: 31-. 1� PECTION ' EE REQUIRE . Prior to next inspection, fee must be at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. CITY OF TUKWILA BUILDING" DIVISION • 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 INSPECTION RECORD stain a copy with permit 1fl/3 //O PERMIT NO. 41) Project: !A' ', / �y e451� 6 b'/f EL E n Type`of Inspection. � /j� % �^- 61 r / / y �CJ / , y . /et. J d Address: . /-?C0/ 3.2 4v s Date Called: Special Instructions: Date Wanted:'. / 0 --/6 --/3 p.m. Requester: Phone No: a) - S —'3O5 f&pproved per applicable codes. El Corrections required prior to approval. COMMENTS: ooer • ge-ef7:450,7( ,72:/vf,Pcr-ri nA1— "./P PC 7o /11,9(4)411k1) e -7 // Date NSPECTION FEEIQUIRED. Pricy to next inspection. fee must be aid at 6300 Southcente Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 (t° Project: 0 AQ I VlEU.) TyRe of Inspection: 0f -M, 2.141-10 NI - ec-r Address: t3(oOt 3,, \U S Date Called: Special Instructions: fi- Date Wanted: Ct-- J — t 3 m. p.m. Requester: Phone No: ca.p ta— ;.-55 —i--13 a5 DApproved per applicable codes. giCorrections required prior to approval. COMMENTS: t\SC P/ecpM-hJ '� e 01) c,d nNo mt 1 iiia L XPi .1'2i1O E-- I ikiS Peo 1 t O.&) Cd Rcn P F 1 lam. t 14-4 G, E - t -c° 04t Y i C >4 5 r I iia C -- 1.1E.to) Date: El INSPECTION FEE RQUIRED. Prior p ;t at 6300 Southcenter Blvd.. Suite 1 o next inspection. fee must be 0. Call to schedule reinspection. PIA^ of GASMETER(5200 M8H.2P51 OUTLET) it 2 WAY FOC rade approves is subject to errors aconstructiond'omissions. 0 0documents does- npt auor of any code or ounce. tipt ro Field Cody and conditions By ._. I 44,�o• Date Le/77/i at y Of 1Ukwiia II. . BUILDING DIVISION SEE Sg9EET C1.2 FOR,CONT. (PIPIN5 UPSTREAM OF PN 6Y DIV. 2000MY. tamJew ACP ‘1.1 E4Pi4'-` este''(° r ` / 1 pig r \\ Li SEPARATE. ptrvirr REQUIRED FOR Meds. CEI ['Plum was of Tu Iles' 'NG D VlSION- KEY NOTES C UNDERGROUND SPRINKLER PIPING (54IN.3' BURY) FOR FDC (BY DN. 15000) PROVIDE THRUST . BLOCKS AT ALL CHANGES IN DIRECTION. O6.. UNDERGROUND SPRINKLER MAIN (61104.3' BURY) BY DN. 15000. PROVIDE THRUST BLOCKS AT ALL CHANGE IN DIRECTION. GAS LINE UPSTREAM OF METER BY WAG. CONTRACTOR TO COORDINATE ROUTING OF OTHER UTILITIES W/ WAC. O. EXISTING GAS METER. WNG TO PROVIDE TEMPORARY CONNECTION TO THIS METER A5 REOUIREO BY PHASED CONSTRUCTION. CONTRACTOR TO COORDINATE THS WORK WITH THE UTILITY COMPANY. C UNDERGROUND FIRE MAN (MIN.3' BURY) BY 04V. 15000. PROVIDE THRUST BLOCKS AT ALL CHANGE IN DIRECTION. OS CW SE(MCE. CONNECT TO EXISTING DOMESTIC WATER SERVICE MANAT LOCATION SHOWN ON SHET77 C1.2. OEXISTING TRANSFORMER VAULT CAREFULLY COORDINATE ALL - 011211E5 IN THIS AREA. OSEE SHEET C1.2 FOR CONNECTION TO 5S. OR S.D.. SYSTEM. • REVIEWED FOR CODEAPCOPROVEbMPUAND E JUN 25 2013 til— V4 City of Tukwila BUILDING DIVISION No ctang -•1 RECEIVED CITY OF TUKWILA JUN 182013 PERMIT CENTER without-pnoc_approval of \:Vila Building Division tai, will require a new plan Submittal 1 11.11I111111111i1 i A 0 C 1.1'1 1 .0 T• • 1011:Western ensue Suite No. : 701 '. Secede. Wo - 98104: . E.206/340-9519 ' RfJBERi F05$ATf ASSOC 001 Saari bmm.'5y.160 5.45401039ni.Mn 0(04 • P 921-1803 F'621-9740 . • HARG15 ENGINEERS; INC • 609 SY.0ttm�n 39.41.Sub 1900 593394. 1 -3376 C 440-4450 Ems, BAR DESIGN COMPANY 911 IFMn Rema / 062 Sottle, 99104 P 76-0126 i 2 S-012! . CIA 99nRera. NN(ANO DENMS 300 ERA P9u Amt Swat* Wastolgton 99122 .P2929 psF . hslitects GEORGE BUNDY,'ori0 ASSOC 1029 NE 894.60 Bed P 523,96901"r"523-131 ' . . THE GREENBUSCH GROUP . 919 IE 71.4 Seattle. m 991(3 P.524-0533 241 FF 504-0830 LICCIERWIEN660/LdI11CN.TO CASCADE r111 ELEISTARDOCt '13601 324 Henn South ' . Tubado. Wmhegton 98168 WPR01fD FOR TIE.98101 JOB 049 99175 . . Ma DATE 3_12-95 CIEOOD MW SrrE- PLAN MECHANICAL COOLING & HEATING REVIEWED FOR QDE COMPLIANCE APPROVED ►JUN 2 5 2013 P -Series Full -line Catalog Commercial -grade Applications Smart, Efficient INVERTER -driven Ductless and Ducted Comfort Systems www.mitsubishipro.com Take a. Closer Look at the P: Series Commercial Systems .z fromM,tsubishi. Electric Coolingand Heating Solutions. 4 Gliameramermweraiim•sttillil' Explore the Ultimate Value in Today's Commercial HVAC Market. For over 30 years Mitsubishi Electric has been a leader in the United States in providing the most energy-efficient, environmentally friendly HVAC products for commercial use. Mitsubishi Electric's advanced technologies include INVERTER -driven compressor systems which use only the exact amount of energy needed to cool or heat an area. This feature means your customers will save energy—and major costs—while experiencing precise control over their comfort year-round. Zone Control plus Personal Control Split ductless and ducted systems userefrigerant lines to connect outdoor units toone or more indoor air handlers. The result of this benefit is that the., temperature within any space with an indoor unit installed can be controlled to provide the perfect temperature. Along with this capability to provide precise temperature control for any space, our systems also offer the unique ability to condition only those spaces in current use at any given time. Mitsubishi Electric's systems employ user-friendly, wireless, wall -mounted, or hand-held controllers which deliver pinpoint comfort very efficiently. Zone control coupled with personal control equals all-around energysavings ;..... ._>... it°a "i • • i€:, State of=the.-,art Design and Smarter 'Functionality When ydii choose Mitsubishi Electric P -Series products for your commercial grade applications, you're making an excellent choice that your customers will appreciate ,for its intelligent,function and the true, year-round • ;eco comfort it delivers. ; { 3 is fat : ; jl, MITSUBISHI ELECTRIC visit www.MitsubishiPro.com Are Mitsubishi Electric P -Series Systems Truly Environmentally Friendly for Commercial Duty? ENERGY STAR PARTNER Count on Mitsubishi Electric to set the standard for making ecologically responsible systems that minimize the impact both on the environment and on your customer's carbon footprint. The fact that 83% of our components are recyclable is just the beginning of our commitment. Mitsubishi Electric has more systems today that are ENERGY STAR certified than ever before. Local and state government plus utility companies provide tax credits and rebate opportunities for energy-efficient systems. Check to see what is available in your area by visiting www.dsireusa.org. How many P -Series systems are ENERGY STAR rated and qualify for the federal tax credit? 9 systems are ENERGY STAR rated PKA-A30KA, PKA-A36KA, PLA-A30BA, PLA-A36BA, PCA-A30KA, PCA-A36KA —, PEA-A18AA (x2), PEAD-A30AA, PEAD-A30AA 2 systems qualify for the federal tax credit PLA-A36BA, PEA-A18°AA For details on qualifying for the tax credit, visit www.mitsubishicomfort.com/taxcredit, and for information on available local rebate opportunities from state or utility companies, visit www.dsireusa.org, which is a U.S. Department of Energy Information service. Table of Contents Introduction and Environmental Information Product Showcase 04 System Overview and Technology 06 System Lineup 08 PKA Wall -Mounted Heat Pump Overview 10 PLA Ceiling -Recessed Heat Pump Overview 10 PEA/PEAD Horizontal Ducted Heat Pump Overview11 H2i® Hyper -Heating INVERTER Overview 12 H2i Heat Pump Specifications 13 PKA Wall -Mounted Specifications 14 PCA Ceiling -Suspended Specifications 16 PLA Ceiling -Recessed Heat Pump Specifications 18 PEA/PEAD Horizontal Ducted Heat Pump Specs 20 H2i Heat Pump Specifications 24 Controllers 26 Accessories 30 Diamondback® Ball Valves 32 Diamondback® Platform Stands 32 Diamondback® Linesets 33 Filter Boxes 33 Line-HideTM 34 Lossnay 34 M -Series / CITY MULTI® Reference 35 Commerical -grade HVAC Applications? Rely on Mitsubishi Electric's rugged, efficient P -Series systems to deliver maximum environmental comfort control plus energy savings for all of your needs. Whatever P -Series system your client selects, you'll be backed start to finish with reliable technical and application support straight from Mitsubishi Electric Cooling and Heating Solutions. Our innovative technologies, environmentally advanced designs, and super -efficient systems are the right solution for your commercial, institutional, and large residential installations. P -Series air conditioners and heat pumps are the perfect choice for an array of demanding commercial settings: • Small or Large Office • Server/Equipment Room • Retail Shop • Restaurant Kitchen • tt ss Center • Classro :MITSUBISHI ELECTRIC visit www.MitsubishiPro.com PCA Indoor Unit Discover How State -of -the -Art Technology Drives De Denc able High Performance in the P -Series . Meet your customers' needs with cooling -only (PUY) or combination heat pump (PUZ) models. Each is compatible with any of the P -Series indoor units. You and your clients benefit from a wide range of installation possibilities. Every rugged outdoor unit is completely assembled, piped, wired, and test -run at the factory prior to shipment. The heavy-duty, commercial -grade cabinet is constructed of galvanized steel plate, finished with electrostatically applied, thermally fused acrylic or polyester powder coating for superb corrosion protection. The front fan grille is tough, high -impact ABS plastic. Highly efficient Mitsubishi Electric INVERTER -driven compressors for models PUY/Z (A18/24/30/36) are DC twin -rotor type. The compressor for model PUY/Z (A42) is a Framed Compliant Scroll compressor. All compressors offer high performance due to advanced variable -speed INVERTER -drive technology, which varies the compressor speed dynamically to adapt continuously to the room load. Excellent efficiency and significant energy savings are the result. Quality construction in every Mitsubishi Electric P -Series unit sets the standard for all HVAC brands in North America. Feature INVERTER Technology Indoor unit powered by outdoor unit Rugged housing, tough cabinet finish, strong welds at numerous stress points Durable, aerodynamic fan design Quiet cooling operation down to 0" F* L -shape condenser coil features copper tubing and aluminum fins Cabinet mounting and construction are designed to withstand 155 MPH Easy interior access to every P -Series indoor and outdoor unit Benefit Maximum energy -efficiency, precise temperature control, more consistent comfort in every space Separate power supply not needed '+ Durability for years of reliable service Super -quiet operation at all speeds High performance for all climates, south to north, east to west Greatly reduced debris accumulation that allows maximum airflow Peace of mind for customers in tomado/ hurricane -prone areas More efficient and less costly routine maintenance and servicing • With optional wind baffle added Electronic linear expansion valves are employed to meter precisely and provide fine controls to adapt continuosly, the refrigerant flow, ensuring exact capacity delivery. Mitsubishi P -Series outdoor models also utilize advanced Pulse Amplitude Modulation (PAM) circuitry. PAM adjusts the form of the current output wave to emulate the form of the supply voltage wave. These technological features offer the advantage that 98 percent of input power is utilized. PUY/PUZ-NHA4 Cooling -only and Heat Pump 12,000 to 18,000 Btu/h 6 :MITSUBISHI ELECTRIC 24,000 to 36,000 Btu/h 42,000 Btu/h visit www.MitsubishiPro.com Va. PUZ-HA**NHA2 (H2i®) Hyper -Heating INVERTER 30,000 to 36,000 Btu/h Mitsu sishi Electric System Technologies Housed in the outdoor unit, the Mitsubishi Electric INVERTER -driven compressor respond to advanced sensor technology to detect subtle changes in temperature. Like a car's cruise control, the sensors automatically adjust compressor speed to adjust system output perfectly. INVERTER -driven compressors dramatically reduce the system's energy use, unlike conventional units that run only at one speed, resulting in an endless wasteful) cycle of starting and stopping. R ENERGY STAR PARTNER Flexible Control User-friendly and efficient zone control gives your customers the option to cool or heat only those Wafts tocnnaroar spaces which are occupied. The controller does not even have to be in the space shared with the indoor unit. Among the energy-saving features of the controller are a weekly timer, temperature range limiting, auto -off, fault code notification, and service -call number display. Easy -Care Filters Convenient tabs make it easy for anyone to remove the washable filters quickly for faster cleaning in the PKA, PCA, and PLA indoor units. Your customers will also save time and money because they won't need to replace the filters. PEA/PEAD models offer optional filter boxes for easy access and service. Auto Cooling/Heating Changeover When set to auto mode, P -Series systems continuously monitor indoor air temperatures, sensing when a space needs cooling or heating. The units automatically switch operation as needed to maintain a consistent level of comfort. Bring in Outside Air You will be able to install ducting with minimal on-site work to bring in outside air for PCA, PLA, and PEA/PEAD indoor units. A healthy, comfortable indoor environment is the result. Energy Recovery Ventilators (ERVs) with integrated controls are also available. Outside air ventilation systems, ducting, and controls are provided separately. INVERTER Compressor Shown inside insulated compartment visit www.MitsubishiPro.com :MITSUBISHI ELECTRIC 7 MUitsu sishi Electric System Technologies In Mitsubishi's P -Series, Four Types of High -Performance Indoor Models Let You Match with a Versatile Lineup of Efficient, INVERTER -driven Outdoor Units to Provide a Truly Custom Solution. P -SERIES INDOOR UNITS: PKA Wall -mounted Air Conditioners and Heat Pumps 12,000-34,200 Btu/h • Sleek, slim -line design • Ductless installation • RedLINKTM enabled for wall -mounted wireless, hand-held wireless or wired controller • Easy -clean, washable filter • Ideal for spaces such as churches, classrooms, daycare centers, out buildings, small offices, and more PLA Ceiling -recessed Air Conditioners and Heat Pumps 12,000-42,000 Btu/h • Space -efficient ductless installation • Built-in condensate lift mechanism • Knockouts for ventilation air and branch duct run • Optional i -see sensor for precise temperature control • Easy -clean, washable filter (optional high -efficiency filter available — requires multifunction casement) • RedLINK enabled for wall -mounted wireless hand-held wireless or wired controller easy -clean, washable filter • Ideal for intermediate retail shops, classrooms, office spaces, conference centers, building lobbies, and more PCA Ceiling -suspended Air Conditioners and Heat Pumps 24,000-42,000 Btu/h • Slim, powerful indoor unit design • Ductless installation • Knockout for ventilation air • Optional i -see sensor for precise temperature control • RedLINK enabled for wall -mounted wireless hand-held, wireless or wired don trolIer • Easy -clean, washable filter • Ideal for larger retail stores, classrooms, restaurants, office spaces, building entrances, plus energy-efficient additions, renovations, and more • Suspends from ceiling for quick easy install PEA/PEAD Horizontal -ducted Air Conditioners and Heat Pumps 12,000-42,000 Btu/h • Unobtrusive concealed ceiling design for short -run ductwork • Built-in condensate lift mechanism • Automatic fan speed control • RedLINK enabled for wall -mounted wireless hand-held, wireless or wired controller • Optional filter boxes for easy access and service • Ideal in retail shopping centers, larger classrooms, auditoriums, office complexes, conference ballrooms, fitness centers, and more • 8 .'.MITSUBISHI ELECTRIC visit www.MitsubishiPro.com See page 26 for information on the MHK1 Remote Controller Kit IVitsuoishi Electric System Technologies et tilt a 1:3 ":1,4 till tt to tt t: Ittt "9zit!:ttti1 I `011 ft *ill sell r stiff fat tut I 144 tet iui t _- Ititie11ii iii t. iiIItti;! :Ai °ris f� :ttt:it t:.j 1 ' i;t4'i` .:*4 1 esti It ft tttit !•, *tt !!i!!!!' '.• Ultimate Comfort Meets Ultimate Convenience Select from a wall -mounted, wireless wall -mounted, or hand-held wireless controller for ultimate comfort control. (PKA-HA/KA) for ultimate comfort control or a handheld wireless controller. The set -temperature display is large and easy to read. Using the 24-hour timer, you can get the unit operation to start and stop at specified times. The convenient remote provides easy control of the fan speed as well as the Cool, Heat, Auto, and Dry modes from anywhere in the room. The hand-held wireless remote controller is easier to use than most TV remotes for P -Series systems. Lightweight, Easy -to -install Indoor Unit The smallest PKA unit measures about 36" wide, 11- 1/2" tall, and 9-3/4" deep. It weighs just 29 lbs., is easily installed above windows or doorways, and can typically be installed by just two licensed installers in about a half day. The wall -mounted models don't require duct work, only a small three-inch opening in the wall or ceiling so they can be installed in some of the toughest spaces even on brick and masonry walls. Auto Vane Control During operation the vane can be adjusted with the remote controller to the perfect position to direct the airflow horizontally in cooling mode or towards the floor in heating mode, keeping room temperature even and comfortable. A simple press of the OFF button results in the vane closing the air outlet for a clean presentation when not in use. Control Airflow Angle for Better Coverage With the wired remote controller four different airflow positions can be set. The AUTO vane feature when in use during cooling permits the angle to self -adjust into a horizontal position and circulate cold air more effectively. During heating the vane directs the hot air downward toward the floor where it will rise and circulate, keeping your room comfortable from top to bottom. The vane closes completely. i-seeTM Sensor Optional Accessory The field -installed i -see sensor accessory improves the operation in the room by sensing and controlling the temperature felt by the room's occupants to help prevent cooling and heating extremes (optional for PU PC models). Taking floor temperature samples five times every 40 seconds over a 160° angle of the surface area, sensors alter the AUTO FAN setting and VANE control setting to account for ambient room temperature fluctuations from the set point. visit www.MitsubishiPro.com ..MITSUBISHI ELECTRIC 9 Vitsu Dish Electric System Technologies i-seeTM Sensor Optional Accessory % eeSensor In addition to the return air temperature sensor, the PLA-A**BA four-way ceiling cassette with the field -installed i -see sensor measures the floor temperature in real time, observing the room vertically for better management of sensible temperature (temperature felt by the occupant). The i -see sensor measures the infrared rays generated from the surrounding wall and floor surface at an angle of 360°. The infrared ray energy, is converted into a temperature value. The i -see sensor rotates 90° slowly in five -second intervals for correct measurement of temperature to cover the full floor space. When combined with the auto fan speed -- mode, air can be directed to the farthest corners of the room for enhanced temperature coverage. i -see sensor detail One Indoor Room Outdoor Unit Two -in -one Twinning If you have a large space such as a long room or hallway which would be considered one zone, two indoor units can be connected to one outdoor unit to cool or heat the space, providing the maximum amount of comfort. The process in which two indoor units act as one to spread the outdoor unit's: capacity over a large area is called twinning. 10 .:MITSUBISHI ELECTRIC visit www.MitsubishiPro.com V itsu dish i Electric System Technologies PEA/PEAD horizontal ducted series Built-in Drain Lift Mechanism The PEA indoor unit features a built-in drain pump that lifts condensation up to 21-11/16 inches above the drain pan and up to 27-9/16 inches for the PEAD indoor unit. The unit's fail-safe mechanism recognizes when there is a high level in the condensate pan and shuts off the indoor fan and the outdoor unit compressor to prevent overflow. When installed, the PEA/PEAD indoor unit utilizes short duct runs, allowing for the air conditioning of adjacent spaces or extending the range of distributed capacities within a single zone with very little visual impact to the conditioned area. With features like a built-in condensate lift mechanism, adjustable static pressure, multiple fan speeds, DRY Mode, and an operating sound as low as 23 dB(A), the PEA/PEAD systems expand the number of application possibilities. PEA PEAD visit www.MitsubishiPro.com MITSt1815Ht ELECTRIC 11 P -Series Hyper -Heating BRINGING YEAR-ROUND COMFORT SOLUTIONS TO EXTREME CLIMATES. Heat Pump System: 30,000 to 34,000 Btu/h Capacity NVERTER Unequaled Year-round Comfort The dual cooling and heating performance of Mitsubishi Electric's INVERTER -driven heat pump systems is appreciated by commercial businesses all across the country. You'll find our Hyper -Heating INVERTER (H2i) P -Series technology advances the benefits a step further with the ultimate in year-round comfort in a single system. The efficient performance and comfort extend to even the coldest days of the year in most areas. The 2.5 and 3 -ton wall -mounted, ceiling -suspended, ceiling -recessed, and ducted units connect to the H2i P -Series outdoor units. This capability gives you customized performance flexible enough to excel in any light commercial application, institutional renovation, or new construction project. Rugged construction ensures cold -weather reliability. The Next Generation in Heat Pump Technology H2i P -Series outdoor units optimize a new level of performance to Mitsubishi Electric P -Series models, furnishing the extra heat -generating power needed to deliver comfort and consistency in extreme climates. H2i units use Mitsubishi's INVERTER -driven scroll compressor technology to achieve the desired room temperature quickly, maintaining it consistently while simultaneously conserving energy. Best of all, the integration of our exclusive H2i flash technology means these H2i P -Series units recover heat energy that is normally wasted in the flash process at the outdoor coil. H2i flash technology helps the system overcome issues associated with conventional heat pumps such as decreases in low -side pressure, refrigerant mass flow rate, and operational capacity. What you'll see is the H2i P -Series units deliver 100 percent of rated heating capacity at 5° F and 80 percent at minus 13° F outdoor ambient temperatures (without the use of energy - consuming electric -resistance heaters). Plus H2i systems use R410A a more efficient and environmentally safe refrigerant. H2i P -Series heat pumps also offer a variety of features designed to take the worry out of temperature control. Two important features are automatic restart after a power outage plus automatic cool/heat changeover. Finally, H2i heat pumps offer long line -length capabilities of up to 245ft., expanding your application options. 6i °.r { Some spaces such as computer or mechanical rooms, or hot kitchens require a distribution of cool air even when the temperature outside is below freezing. Air conditioning down to 0° F is achievable with the addition of wind baffles. Whether cooling or heating, the H2i P -Series helps you offer your clients the flexibility to temper extreme outdoor temperatures. Warm Air Quickly At startup a special circuit in H2i P -Series quickly delivers refrigerant to the air-conditioning cycle, which rapidly increases the mass flow rate in the system. As a result, air at comfortable temperatures begins flowing from indoor units right away. Even at an outdoor temperature of -13° F, the H2i P -Series system can discharge 100° F temperature air from the indoor units. At 5° F outdoor temperature and above, the discharge temperature reaches an impressive 110° F with a 40° F temperature rise (see Figure 2). This feature translates into a comfortable climate in all zones whether cooling or heating, no matter the temperature outside. 12 Att.MITSUBISHI EIECTRtC visit www.MitsubishiPro.com IV itsu sishi Electric P -Series Hyper -Heating (Figure 1) Hyper -Heating INVERTER vs. Other Units Heating Capacity vs- Outdoor Temperature 120-� 100 80 Y U c x 60 40 1 • 20 0' -13 -4 0 5 10 17 25 30 35 40 47 Outdoor Temperature Degrees FWB (Figure 2) 110 108 106 104 102 i;, 100 m v 98 N CI 96 r ; -4—Mitsubishi Electric Hyper -Heating INVERTER (H2i1 —F Mitsubishi Electric Standard INVERTER heat pump system —1 -Typical Unitary Equipment Performance Does not include correction factor for defrost Indoor Unit Discharge Temperature (wall -mounted indoor unit with fan on high) 94 -13 -4 Outdoor Temperature (° F WB) ENERGY STAR® and Tax Credit Systems Nine (9) H2i P -Series systems are ENERGY STAR rated, and two (2) systems qualify for the federal tax credit. ENERGY STAR PUZ-HA3ONHA COP if PKA PLA PCA PEAD 47° F 3.20 2.72 3.13 3.41 17° F 1.84 1.63. 1.81 1.90 5° F 1.62 1.41 1.60 1.73 PUZ-HA36NHA CAW it I'I(A FLA t UA I tAD 47° F 3.26 3.44 3.40 3.53 17° F 1.85 2.10 1.94 2.06 5° F 1.64 ' 1.90 1.70 1.82 ENERGY STAR Tax Credit PKA-A3OKA4 PLA-A36BA4 PKA-A36KA4 PEA -A1 8AA4(x2) PLA-A3OBA4 PLA-A36BA4 PCA-A30KA4 PCA-A36KA4 PEA -Al 8AA4(x2) PEAD-A30AA4 PEAD-A36AA4 Heating Performance at Low Temperatures, OurrHyper: Heating INVERTER system provides outstanding heating performance at extremely low temperatures while keeping effective energy usage at the forefront° See the impressive COP (Coefficient of Performance) values in the table to the left. The Mitsubishi H2i P -Series systems are able to maximize efficiency at low temperatures while providing tremendous heating output. visit www.MitsubishiPro.com :MITSUBISHI ELECTRIC 13 BS = Seacoast Protection • (PKA-A30)1 MODEL SHOWN) PKA COOLING -ONLY Model Name Cooling *1 Indoor Unit Outdoor Unit Rated Capacity Btulh PKA-Al2HA4 PUY-Al2NHA4 -BS 12,000 PKA-A18HA4 PUY-A1BNHA4 -BS PKA-A24KA4 PUY-A24NHA4 -BS 24,000 PKA-A30KA4 PUY-A3ONHA4 -B 30,000 PKA-A36KA4 PUY-A36NHA4 -BS 34,200 18,000 Capacity Range Btu/h 6,000-12,000 8,000-18,000 12,000-24,000 12,000-30,000 • 12,000-34,200 Total Input W 1,190 2,240 2,270 4,130 5,030 Energy Efficiency SEER 15.2 15.3 17.0 15.5 14.0 Moisture Removal Pintsm 2.0 5.2 5.0 8.1 9.2 Sensible Heat Factor 0.81 0.68 0.77 0.70 0.70 Power Supply Phase, Cycle, Voltage 1 -phase, 60Hz, 208 / 230V *2 Voltage Indoor - Outdoor S1 - S2 AC 208 / 230V Indoor - Outdoor S2 - S3 DC24 Indoor Unit MCA A 1 Fan Motor F.L.A. 0.33 0.36 0.57 Fan Motor Output W 30 56 56 Airflow (Lo -Mid -Hi) DRY (CFM) 320-370-425 635-705-775 705-810-920 WET (CFM) 290-335-380 570-635-700 635-730-830 Sound Pressure Level (Lo -Mid -Hi) dB(A) 36-40-43 39-42-45 43-46-49 External Finish Color Munsell No. 1.OY 9.2 / 0.2 Dimension Unit W: In. 35-3/8 46-1/16 D: In. 9-13/16 11-5/8 H: In. 11-5/8 14-3/8 Weight Unit Lbs. 29 46 Field Drainpipe Size 0.D. In. 5/8 Outdoor Unit MCA A 13 18 25 Recommended Fuse/Breaker Size A 15 25 30 MOCP A 15 1 20 30 40 Fan Motor FL A 0.35 0 75 Fan Motor Output W 40 75 Compressor Model (Type) DC INVERTER -driven Twin Rotary R.L.A. 12 L.R.A. 14 17.5 Airflow CFM 1,200 1 1,940 Refrigerant Control Linear Expansion Valve Sound Pressure Level at Cooling *1 dB(A) 46 48 External Finish Color Munsell No. 3Y 7.8 / 1.1 Dimensions W: In. 31-1/2 37-3/8 D: In. 11-13/16 + 7/8 13 + 1-3/16 H: In. 23-5/8 37-1/8 Weight Lbs. 82 1 89 163 Refrigerant Type R410A Charge Lbs., oz. 2,14 3,12 6,10 Oil Type (fl. oz.) FV5OS (20) FV5OS (28) Refrigerant Pipe Gas Side O.D. In. 1/2 5/8 Liquid Side 0.D. In. 1/4 3/8 Refrigerant Pipe Length Height Difference (Max.) Ft. 100 Length (Max.) Ft. 100 165 Connection Method Indoor/Outdoor Flared/Flared NOTES: Test conditions are based on AHRI 210/240. *1. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C). *2. Indoor units receive power from outdoor units through field -supplied interconnected wiring. Specifications are subject to change without notice. LIMITED WARRANTY ISeven-year warranty on compressor. Five-year warranty on parts. 14 .MITSUBISHI ELECTRIC visit www.MitsubishiPro.com (PKA-A30KA4 MODEL SHOWN) PKA HEAT PUMP ER BS = Seacoast Protection Model Name Cooling *1 Indoor Unit Outdoor Unit Rated Capacity Btu/h PKA-A18HA4 PUZ-A18NHA4 -BS 18,000 PKA-A24KA4 PUZ-A24NHA4 -BS 24,000 PKA-A3OKA4 PUZ-A3ONHA4 -BS 30,000 PKA-A36KA4 PUZ-A36NHA4 -BS 34,200 Capacity Range Btu/h 8,000-18,000 12,000-24,000 12,000-30,000 12,000-34,200 Total lnput W 2,240 2,270 4,130 5,030 Energy Efficiency SEER 15.3 17.0 15.5 14.0 Moisture Removal Pints/h 5.2 5.0 8.1 9.2 Sensible Heat Factor 0.68 0.77 0.70 0.70 Heating at 47° F'2 Rated Capacity Btu/h 19,000 26,000 32,000 37,000 Capacity Range Btu/h 8,000-20,000 12,000-28,000 12,000-34,000 12,000-38,000 Total Input W 1,970 2,330 3,150 3,610 HSPF (IV) Btu/h/W 9.5 10.8 8.9 9.3 Heating at 17° F'3 Capacity Btu/h 13,000 18,000 23,000 25,000 Total Input W 1,670 2,200 2,850 3,030 Power Supply Phase, Cycle, Voltage 1 -phase, 60Hz 208 / 230V *4 Voltage Indoor - Outdoor S1 - S2 AC 208 / 230V Indoor - Outdoor S2 - S3 DC24 Indoor Unit MCA A 1 Fan Motor F.L.A. 0.33 0.36 0.57 Fan Motor Output W 30 • 56 56 Airflow (Lo -Mid -H1) DRY (CFM) 320-370-425 635-705-775 705-810-920 WET (CFM) 290-335-380 570-635-700 635-730-830 Sound Pressure Level (Lo -Mid -Hi) dB(A) 36-40-43 39-42-45 43-46-49 External Finish Color Munsell No. 1.0Y 9.2 / 0.2 Dimension Unit W: In. 35-3/8 46-1/16 D: In. 9-13/16 11-5/8 H: In. 11-5/8 14-3/8 Weight Unit Lbs. 29 46 Field Drainpipe Size 0.D. In. 5/8 Outdoor Unit MCA A 13 18 25 Recommended Fuse/Breaker Size A 15 25 30 MOCP A 20 30 40 Fan Motor F.L.A. 0.35 0.75 Fan Motor Output W 40 75 Compressor Model (Type) DC INVERTER -driven Twin Rotary R.L.A. 12 L.R.A. 14 17.5 Airflow CFM 1,200 1 1,940 Refrigerant Control Linear Expansion Valve Defrost Method Reverse Cycle Sound Pressure Level at Cooling *1 dB(A) 48 Sound Pressure Level at Heating *2 dB(A) 47 50 External Finish Color Munsell No. 3Y 7.8 / 1.1 Dimensions W: In. 31-1/2 37-3/8 0: In. 11-13/16 +7/8 13 + 1-3/16 H: In. 23-5/8 37-1/8 Weight Lbs. 91 165 Refrigerant Type R410A Charge Lbs., oz. 3,12 6, 10 Oil Type (fl. oz.) FV5OS (20) FV5OS (28) Refrigerant Pipe Gas Side O.D. In. 1/2 5/8 Liquid Side O.D. In. 1/4 3/8 Refrigerant Pipe Length Height Difference (Max.) Ft 100 Length (Max.) Ft. 100 165 Connection Method Indoor/Outdoor Flared/Flared NOTES: Test conditions are based on AHRI 210/240. I. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor. D.B. 95° F (35° C), W.B. 75° F (24° C). '2. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: O.B. 47° F (8° C), W.B. 43° F (6° C). *3. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: D.B. 17° F (-8.3° C), W.B. 15° F (-9° C). *4. Indoor units receive power from outdoor units through field -supplied interconnected wiring. Specifications are subject to change without notice. LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on parts. visit www.MitsubishiPro.com .tMrTSUBISHI ELECTRIC 15 Ityairz R PCA COOLING -ONLY (PCA-A36KA4 MODEL SHOWN) BS = Seacoast Protection Model Name Cooling *1 Indoor Unit Outdoor Unit Rated Capacity Btu/h PCA-A24KA4 PUY-A24NHA4 -BS 24,000 PCA-A30KA4 PUY-A3ONHA4 -BS 30,000 PCA-A36KA4 PUY-A36NHA4 -BS 35,000 PCA-A42KA4 PUY-A42NHA4 -BS 42,000 Capacity Range Btu/h 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000 Total Input W 2,340 3,760 4,630 4,110 Energy Efficiency SEER 16.8 14.5 14.4 15.8 Moisture Removal Pints/h 5.8 8.3 8.5 11.7 Sensible Heat Factor 0.73 0.69 0.73 0.69 Power Supply Phase, Cycle, Voltage 1 -phase, 60Hz, 208 / 230V'2 Voltage Indoor - Outdoor S1 - S2 AC 208 / 230V Indoor - Outdoor S2 - S3 DC24V Indoor Unit MCA A 1 2 Fan Motor F.L.A. 0.54 0.97 Fan Motor Output W 95 160 Airflow (Lo-M1-M2-Hi)DRY (CFM) 530-565-600-670 565-600-635-705 775-850-920-990 810-885-955-1,025 WET (CFM) 495-530-565-635 530-565-600-670 705-775-850-920 740-810-885-955 Sound Pressure Level (Lo -M1 -M2 -Hi) dB(A) 33-35-37-40 35-37-39-41 37-39-41-43 39-41-43-45 External Finish Color Munsell No. 6.4Y 8.9 / 0.4 Dimension Unit W: In. 50-3/8 1 63 D: In. 26-3/4 H: In. 9-1/16 Weight Unit Lbs. 71 1 79 1 84 Field Drainpipe Size 0.D. In. 1-1/16 Outdoor Unit MCA A 18 25 1 26 Recommended Fuse/Breaker Size A 25 30 MOCP A 30 40 Fan Motor FLA 0.75 0 4 + 0 4 Fan Motor Output W 75 86 + 86 Compressor Model (Type) DC INVERTER -driven Twin Rotary INVERTER -driven Scroll R.LA. 12 20 L.R.A. 14 17.5 27.5 Airflow CFM 1,940 3,530 Refrigerant Control Linear Expansion Valve Sound Pressure Level at Cooling *1 dB(A) 48 51 External Finish Color Munsell No. 3Y 7.8 / 1.1 Dimensions W: In. 37-3/8 D: In. 13 + 1-3/16 H: In. 37-1/8 53-1/8 Weight Lbs. 163 258 Refrigerant Type R410A Charge Lbs., oz. 6,10 10 Oil Type M. oz.) FV5OS (28) FV50S (45) Refrigerant Pipe Gas Side O.D. In. 5/8 Liquid Side 0.D. In. 3/8 Refrigerant Pipe Length Height Difference (Max.) Ft. 100 Length (Max.) Ft. 165 Connection Method Indoor/Outdoor Flared/Flared NOTES: Test conditions are based on AHRI 210/240. "1. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C). *2. Indoor units receive power from outdoor units through field -supplied interconnected wiring. Specifications are subject to change without notice. LIMITED WARRANTY ( Seven-year warranty on compressor. Five-year warranty on parts. 16 AMITSUBISHI ELECTRIC Visit www.MitsubishiPro.com (PCA-A36KA4 MODEL SHOWN) PCA HEAT PUMP BS = Seacoast Protection Model Name Cooling *1 Indoor Unit Outdoor Unit Rated Capacity Btu/h PCA-A24KA4 PUZ-A24NHA4 -BS 24,000 PCA-A3OKA4 PUZ-A3ONHA4 -BS 30,000 PCA-A36KA4 PUZ-A36NHA4 -BS 35,000 PCA-A42KA4 PUZ-A42NHA4 -BS 42,000 Capacity Range Btu/h 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000 Total Input W 2,340 3,760 4,630 4,110 Energy Efficiency SEER 16.8 14.5 14.4 15.8 Moisture Removal Pints/h 5.8 8.3 8.5 11.7 Sensible Heat Factor 0.73 0.69 0.73 0.69 Heating at 47° F'2 Rated Capacity Btu/h 26,000 32,000 37,000 45,000 Capacity Range Btu/h 12,000-28,000 12,000-34,000 12,000-38,000 18,000-48,000 Total Input W 2,310 3,210 3,190 3,830 HSPF (IV) Btu/h/W 10.9 9.2 10.2 10.2 Heating at 17° F'3 Capacity Btu/h 18,000 23,000 25,000 30,000 Total lnput W 2,200 2,940 2,800 3,820 Power Supply Phase, Cycle, Voltage 1 -phase, 60Hz 208 / 230V *4 Voltage Indoor - Outdoor Si - S2 AC 208 / 230V Indoor - Outdoor S2 - S3 DC24V Indoor Unit MCA A 1 2 Fan Motor F.L.A. 0.54 0.97 Fan Motor Output W 95 160 Airflow (Lo -M1 -M2 -Hi) DRY (CFM) 530-565-600-670 565-600-635-705 775-850-920-990 810-885-955-1,025 WET (CFM) 495-530-565-635 530-565-600-670 705-775-850-920 740-810-885-955 Sound Pressure Level (Lo -M1 -M2 -Hi) dB(A) 33-35-37-40 35-37-39-41 37-39-41-43 39-41-43-45 External Finish Color Munsell No. 6.4Y 8.9 / 0.4 Dimension Unit W: In. 50-3/8 1 63 D: In. 26-3/4 H: In. • 9-1/16 Weight Unit Lbs. 71 1 79 1 84 Field Drainpipe Size 0.0. In. 1-1/16 Outdoor Unit MCA A 18 25 1 26 Recommended Fuse/Breaker Size A 25 30 MOCP A 30 . 40 Fan Motor F.L.A. 0.75 0.4 + 0.4 Fan Motor Output W 75 86 + 86 Compressor Model (Type) DC INVERTER -driven Twin Rotary INVERTER -driven Scroll R.L.A. 12 20 L.R.A. 14 17.5 27.5 Airflow CFM 1,940 3,530 Refrigerant Control Linear Expansion Valve Defrost Method Reverse Cycle Sound Pressure Level at Cooling *1 dB(A) 48 51 Sound Pressure Level at Heating *2 dB(A) 50 55 External Finish Color Munsell No. 3Y 7.8 / 1.1 Dimensions W: In. 37-3/8 D: In. 13 + 1-3/16 H: In. 37-1/8 53-1/8 Weight Lbs. 165 260 Refrigerant Type R410A Charge Lbs., oz. 6,10 10 Oil Type (fl. oz.) FV5OS (28) FV5OS (45) Refrigerant Pipe Gas Side 0.0. In. 5/8 Liquid Side 0.D. In. 3/8 Refrigerant Pipe Length Height Difference (Max.) Ft. 100 Length (Max.) Ft. 165 Connection Method Indoor/Outdoor Flared/Flared NOTES: Test conditions are based on AHRI 210/240. . Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C). *2. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: D.B. 47° F (8° C), W.B. 43° F (6° C). *3. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: 0.6.17° F (-8° C), W.B. 15° F (-9° C). *4. Indoor units receive power from outdoor units through field -supplied interconnected wiring. Specifications are subject to change without notice. visit www.MitsubishiPro.com LIMITED WARRANTY I Seven-year warranty an compressor. Five-year warranty on parts. MITSUBISHI ELECTRIC 17 (PLA-A368A4 MODEL SHOWN WITH OP11ONAL i -seer" SENSOR) BS = Seacoast Protection PLA COOLING -ONLY Model Name Cooling *1 Indoor Unit Outdoor Unit Rated Capacity Btu/h PLA-Al2BA4 PUY-Al2NHA4 (-BS) 12,000 PLA-A18BA4 PUY-A18NHA4 (-BS) 18,000 PLA-A24BA4 PUY-A24NHA4 (-BS) 24,000 PLA-A3OBA4 PUY-A3ONHA4 (-BS) 30,000 PLA-A36BA4 PLA-A42BA4 PUY-A36NHA4 (-BS) PUY-A42NHA4 (-BS) 35,000 42,000 Capacity Range Btu/h 6,000-12,000 8,000-18,000 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000 Total Input W 1,260 1,940 2,500 4,100 4,500 4,600 Energy Efficiency SEER 13.5 14.2 13.6 14.2 14.4 Moisture Removal Pints/b 1.7 3.0 5.1 7.2 8.1 10.9 Sensible Heat Factor 0.84 0.81 0.76 0.73 0.74 0.71 Power Supply Phase, Cycle, Voltage 1 -phase, 60Hz, 208 / 230V *2 Voltage Indoor - Outdoor S1 - S2 AC 208 / 230V Indoor - Outdoor S2 - S3 DC24V Indoor Unit MCA A 1 2 Fan Motor F.L.A. 0.51 1.00 Fan Motor Output W 50 120 Airflow (Lo -Ml -M2-Hi) DRY (CFM) 390-420-460-530 420-490-570-640 490-570-640-740 710-810-920-1,060 780-880-990-1,090 WET (CFM) 350-390-420-490 390-460-530-600 460-530-600-710 670-770-880-1,030 740-850-950-1,060 Sound Pressure Level (Lo -M1 -M2 -Hi) dB(A) 27-28-29-31 28-29-31-32 28-30-32-34 32-34-37-40 34-36-39-41 External Finish Color (Panel) Munsell No. 6 4Y 8.9 / 0.4 Dimension Unit (Panel) W: In. 33-1/16 (37-3/8) D: In. 33-1/16 (37-3/8) H: In. 10-3/16 (1-3/8) 11-3/4 (1-3/8) Weight Unit (Panel) Lbs. 49 (13) I 51 (13) 55 (13) Drain Lift Mechanism (Included) H: In. 33-7/16 Field Drainpipe Size 0.D. In. 1-1/4 Outdoor Unit MCA A 13 18 25 ] 26 Recommended Fuse/ Breaker Size A 15 25 30 MOCP A 15 1 20 30 40 Fan Motor F.L.A. 0.35 0.75 0.4 + 0.4 Fan Motor Output W 40 75 86 + 86 . Compressor Model (We) DC INVERTER -driven Twin Rotary INVERTER driven Scroll R.LA. 12 20 L.R.A. 14 17.5 27.5 Airflow CFM 1,200 1 1,940 3,530 Refrigerant Control Linear Expansion Valve Sound Pressure Level at Cooling *1 dB(A) 46 48 51 External Finish Color Munsell No. 3Y 7.8 / 1.1 Dimensions W: In. 31-1/2 37-3/8 D: In. 11-13/16+ 7/8 13+1-3/16 H: In. 23-5/8 37-1/8 53-1/8 Weight Lbs. 82 1 89 163 258 Refrigerant Type R410A Charge Lbs., oz. 2 4 3, 12 6, 10 10 Oil Type (fl. oz.) FV50S(20) FV50S(28) FV50S(45) Refrigerant Pipe Gas Side 0.D. In. 1/2 5/8 Liquid Side O.D. In. 1/4 3/8 Refrigerant Pipe Length Height Difference (Max.) Ft. 100 Length (Max.) Ft. 100 165 Connection Method Indoor/Outdoor Flared/Flared NOTES: Test conditions are based on AHRI 210/240. "1. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor. D.B. 95° F (35° C), W.B. 75° F (24° C). "2. Indoor units receive power from outdoor units through field -supplied interconnected wiring. Specifications are subject to change without notice. UNITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts. 18 ..MITSUBISHI ELECTRIC visit www.MitsubishiPro.com PLA HEAT PUMP (PLA-A36BA4 MODEL SHOWN WITH OPTIONAL I -see. SENSOR) BS = Seacoast Protection Model Name Cooling *1 Indoor Unit Outdoor Unit Rated Capacity Btu/h PLA-A18BA4 PUZ-A18NHA4 -BS 18,000 PLA-A24BA4 PUZ-A24NHA4 -BS 24,000 PLA-A3OBA4 PUZ-A3ONHA4 -BS 30,000 PLA-A36BA4 PUZ-A36NHA4 -BS 35,000 PLA-A42BA4 PUZ-A42NHA4 -BS 42,000 Capacity Range Btu/h 8,000-18,000 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000 Total lnput W 1,940 2,500 4,100 4,500 4,600 Energy Efficiency SEER 14.2 13.6 14.2 14.4 Moisture Removal Pints/h 3.0 5.1 7.2 8.1 10.9 Sensible Heat Factor 0.81 0.76 0.73 0.74 0.71 Heating at 47° F'2 Rated Capacity Btu/h 19,000 26,000 32,000 37,000 45,000 Capacity Range Btu/h 8,000-20,000 12,000-28,000 12,000-34,000 12,000-38,000 18,000-48,000 Total Input W 1,900 2,570 3,370 3,300 4,450 HSPF (110 Btu/h/W 9.8 8.5 8.7 9.3 Heating at 17° F'3 Capacity Btu/h 13,000 16,000 23,000 25,000 30,000 Total Input W 1,590 2,200 3,050 3,070 4,300 Power Supply Phase, Cycle, Voltage 1 -phase, 60Hz, 208 / 230V'4 Voltage Indoor - Outdoor S1 - S2 AC 208 / 230V Indoor - Outdoor S2 - S3 OC24V •dB(A) Indoor Unit MCA A 1 2 Fan Motor F.L.A. 0.51 1.00 Fan Motor Output W 50 120 Airflow (Lo -M1 -M2 -Hi) DRY (CFM) 420-490-570-640 490-570-640-740 710-810-920-1,060 780-880-990-1,090 WET (CFM) 390-460-530-600 460-530-600-710 670-770-880-1,030 740-850-950-1,060 Sound Pressure Level (Lo-M1- M2 -Hi) 28-29-31-32 28-30-32-34 32-34-37-40 34-36-39-41 External Finish Color (Panel) Munsell No. 6.4Y 8.9 / 0.4 Dimension Unit (Panel) W: In. 33-1/16 (37-3/8) D: In. 33-1/16 (37-3/8) H: In. 10-3/16 (1-3/8) 11-3/4 (1-3/8) Weight Unit (Panel) Lbs. 49 (13) 1 51 (13) 55 (13) Drain Lift Mechanism (Included) H: In. 33-7/16 Field Drainpipe Size 0.D. In. 1-1/4 Outdoor Unit MCA A 13 18 25 1 26 Recommended Fuse/Breaker Size A 15 25 30 MOCP A 20 30 40 Fan Motor F.L.A. 0.35 0.75 0.4 + 0.4 Fan Motor Output W 40 75 86 + 86 Compressor Model (Type) DC INVERTER -driven Twin Rotary INVERTER -driven Scroll R.L.A. 12 20 L.R.A. 14 17.5 27.5 Airflow CFM 1,200 1 1,940 3,530 Refrigerant Control Linear Expansion Valve Defrost Method Reverse Cycle Sound Pressure Level at Cooling *1 dB(A) 48 51 Sound Pressure Level at Heating *2 dB(A) 47 50 55 External Finish Color Munsell No. 3Y 7.8 / 1.1 Dimensions W: In. 31-1/2 37-3/8 D: In. 11-13/16 + 7/8 13 + 1-3/16 H: In. 23-5/8 37-1/8 53-1/8 Weight Lbs. 91 165 260 Refrigerant Type R410A Charge Lbs., oz. 3,12 6,10 10 Oil Type (0. oz.) FV5OS (20) FV5OS (28) FV5OS (45) Refrigerant Pipe Gas Side 0.D. In. 1/2 5/8 Liquid Side 0.D. In. 1/4 3/8 Refrigerant Pipe Length Height Difference (Max.) Ft. 100 Length (Max.) Ft. 100 165 Connection Method Indoor/Outdoor Flared/Flared NOTES: Test conditions are based on AHRI 210/240. *1 Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C). *2 Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: D.B. 47° F (8° C), W.B. 43° F (6.1° C). LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on pans. visit www.MitsubishiPro.com *3. Rating conditions (heating) -Indoor. D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: D.B. 17° F (-8° C), W.B. 15° F (-9° C). *4. Indoor units receive power from outdoor units through field -supplied interconnected wiring. Specifications are subject to change without notice. MITSUBISHI ELECTRIC 19 (PEA 'At8AA4 MODEL SHOWN) BS = Seacoast Protection PEA/PEAD COOLING -ONLY Model Name Cooling *1 Indoor Unit Outdoor Unit Rated Capacity Btu/h PEA-Al2AA4 PEA-A18AA4 PEAD-A24AA4 PEAD-A30AA4 PEAD-A36AA4 PUY-Al2NHA4 -BS PUY-A18NHA4 -BS PUY-A24NHA4 -BS PUY-A3ONHA4 -BS PUY-A36NHA4 -BS PEAD-A42AA4 PUY-A42NHA4 -BS 42,000 12,000 18,000 24,000 30,000 35,000 Capacity Range Btu/ft 6,000-12,000 8,000-18,000 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000 Total lnput W 1,240 2,150 2,400 3,850 4,850 5,350 Energy Efficiency SEER 13.8 14.3 16.0 15.5 15.0 13.8 Moisture Removal Pints/h 2.47 3.26 6.9 8.6 7.9 9.0 Sensible Heat Factor 0.77 0.80 0.68 0.75 0.76 Power Supply Phase, Cycle, Voltage 1 -phase, 60Hz, 208 / 230V *2 Voltage Indoor - Outdoor S1 - S2 AC208/230V Indoor - Outdoor S2 - S3 DC24V Indoor Unit MCA A 1 2 2.63 2.73 3.30 3.50 Fan Motor F.L.A. 0.57 0.74 2.10 2.18 2.64 2.80 Fan Motor Output W 96 121 244 Airflow (Lo -Mid -Hi) DRY (CFM) 247-317-388 423-529-635 512-636-742 618-742-883 847-1,024-1,201 1,042-1,254-1,483 WET (CFM) 222-285-349 381-476-572 494-600-671 565-671-812 777-953-1,130 953-1,165-1,412 External Static Pressure In. WG 0.02 - 0.06 0.14 - 0.20 0.14 - 0.20 - 0 28 - 0.40 - 0.60 Sound Pressure Level (Lo -Mid -Hi) dB(A) 23-28-33 30-34-38 30-33-37 30-34-39 33-38-42 36-40-44 External Finish Color Galvanized -steel Sheet Dimension Unit W: In. 39 1 46-7/8 43-5/16 1 55-1/8 D: In. 27-9/16 28-7/8 H: In. 7-7/8 9-7/8 Weight Unit Lbs. 48 1 62 73 1 91 1 95 Drain Lift Mechanism (Included) H: In. 21-11/16 27-9/16 Field Drainpipe Size 0.D. In. 1-1/4 Outdoor Unit MCA A 13 18 25 26 Recommended Fuse/ Breaker Size A 15 25 30 MOCP A 15 1 20 30 40 Fan Motor F.L.A. 0.35 0.75 0.4 + 0.4 Fan Motor Output W 40 75 86 + 86 Compressor Model (TYPO INVERTER -driven Twin Rotary INVERTER -driven Scroll Scroll R.L.A. 12 20 L.R.A. 14 1 17.5 27.5 Airflow CFM 1,200 1,940 3,530 Refrigerant Control Linear Expansion Valve Sound Pressure Level at Cooling '1 dB(A) 46 48 51 External Finish Color Munsell No. 3Y 7.8 / 1.1 Dimensions W: In. 31-1/2 37-3/8 D: In. 11-13/16 + 7/8 13 + 1-3/16 H: In. 23-5/8 37-1/8 53-1/8 Weight Lbs. 82 1 89 163 258 Refrigerant Type R410A Charge Lbs., Oz. 2 14 3,12 6,10 10 011 Type (fl. oz.) FV5OS (20) FV5OS (28) FV5OS (45) Refrigerant Pipe Gas Side 0.D. In. 1/2 5/8 Liquid Side O.D. In. 1/4 3/8 Refrigerant Pipe Length Height Difference (Max.) Ft. 100 Length (Max.) Ft. 100 165 Connection Method Indoor/Outdoor Flared/Flared NOTES: Test conditions are based on AHRI 210/240. *1. Rating conditions (cooling) -Indoor: D.B. 80° F (27° C), W.B. 67° F (19° C); Out- door: D.B. 95° F (35° C), W.B. 75° F (24° C). *2. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Out- door. D.B. 47° F (8° C), W.B. 43° F (6.1° C). LIMITED WARRANTY Seven-year warranty on compressor. Five-year warranty on parts. 20 A MITSUBISHI ELECTRIC *3. Rating conditions (heating) -Indoor. D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: D.B. 17° F (-8° C), W.B. 15° F (-9° C). *4. Indoor units receive power from outdoor units through field -supplied interconnected wiring. Specifications are subject to change without notice. visit www.MitsubishiPro.com (PEA -A1 8AA- MODEL SHOWN) BS = Seacoast Protection PEA/PEAD HEAT PUMP Model Name Cooling *1 Indoor Unit Outdoor Unit Rated Capacity Btu/h PEA-AlBAA4 PUZ-A18NHA4 -BS 18,000 PEAD-A24AA4 PUZ-A24NHA4 -BS 24,000 PEAD-A30AA4 PUZ-A3ONHA4 -BS 30,000 PEAD-A36AA4 PUZ-A36NHA4 -BS 35,000 PEAD-A42AA4 PUZ-A42NHA4 -BS 42,000 Capacity Range Btu/h 8,000-18,000 12,000-24,000 12,000-30,000 12,000-35,000 18,000-42,000 Total Input W 2,150 2,400 3,850 4,850 5,350 Energy Efficiency SEER 14.3 16.0 15.5 15.0 13.8 Moisture Removal Pints/h 3.26 6.9 8.6 7.9 9.0 Sensible Heat Factor 0.80 0 68 0.75 0.76 Heating at 47° F *2 Rated Capacity Btu/h 19,000 26,000 32,000 37,000 45,000 Capacity Range Btu/h 8,000-20,000 12,000-28,000 12,000-34,000 12,000-38,000 18,000-48,000 Total Input W 1,540 2,250 2,990 3,290 3,820 HSPF (IV) Btu/h/W 10 10.2 9.4 9.8 10.0 Heating at 17° F'3 Capacity Btu/h . 13,000 18,000 23,000 25,000 30,000 Total Input W 1,520 2,130 2,750 2,810 3,820 Power Supply Phase, Cycle, Voltage 1 -phase, 60Hz, 208 / 230V'4 Voltage Indoor - Outdoor S1 - S2 AC208/230V Indoor - Outdoor S2 - S3 DC24V Indoor Unit MCA A 2 2.63 2.73 3.30 3.50 Fan Motor F.L.A. 0.74 2.10 2.18 2.64 2.80 Fan Motor Output W 96 121 244 Airflow (Lo -Mid -Hi) DRY (CFM) 423-529-635 512-636-742 618-742-883 847-1,024-1,201 1,042-1,254-1,483 WET (CFM) 381-476-572 494-600-671 565-671-812 777-953-1,130 953-1,165-1,412 External Static Pressure In. WG 0.02 - 0.06 - 0.14 - 0.20 0.14 - 0.20 - 0.28 - 0.40 - 0.60 Sound Pressure Level (Lo -Mid -Hi) dB(A) 30-34-38 30-33-37 1 30-34-39 33-38-42 1 36-40-44 External Finish Color Galvanized -steel Sheet Dimension Unit W: In. 46-7/8 43-5/16 1 55-1/8 D: In. 27-9/16 28-7/8 H: In. 7-7/8 9-7/8 Weight Unit Lbs. 62 73 91 1 95 Drain Lift Mechanism (Included) H: In. 21-11/16 27-9/16 Field Drainpipe Size O.D. In. 1-1/4 Outdoor Unit MCA A 13 18 25 1 26 Recommended Fuse/Breaker Size A 15 25 30 MOCP A 20 30 40 Fan Motor F.L.A. 0.35 0.75 0.4 + 0.4 Fan Motor Output W 40 75 86 + 86 Compressor Model Type) DC INVERTER -driven Twin Rotary INVERTER -driven Scroll R.L.A. 12 20 L.R.A. 14 17.5 27.5 Airflow CFM 1,200 1 1,940 3,530 Refrigerant Control Linear Expansion Valve Defrost Method Reverse Cycle Sound Pressure Level at• Cooling *1 d8(A) 48 51 Sound Pressure Level at Heating *2 d8(A) 47 50 55 External Finish Color Munsell No. 3Y 7.8 / 1.1 Dimensions W: In. 31-1/2 37-3/8 D: In. 11-13/16 + 7/8 13 + 1-3/16 H: In. 23-5/8 37-1/8 53-1/8 Weight Lbs. 91 165 260 Refrigerant Type R410A Charge Lbs., Oz. 3,12 6,10 10 Oil Type (fl. oz.) FV5OS (20) FV5OS (28) FV5OS (45) Refrigerant Pipe Gas Side O.D. In. 1/2 5/8 Liquid Side 0.0. In. 1/4 3/8 Refrigerant Pipe Length Height Difference (Max.) Ft. 100 Length (Max.) Ft. 100 165 Connection Method Indoor/Outdoor Flared/Flared NOTES: Test conditions are based on AHRI 210/240. I. Rating conditions (cooling) -Indoor. D.B. 80° F (27° C), W.B. 67° F (19° C); Outdoor: D.B. 95° F (35° C), W.B. 75° F (24° C). *2. Rating conditions (heating) -Indoor: D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor. D.B. 47° F (8° C), W.B. 43° F (6.1° C). LIMITED WARRANTY 1 Seven-year warranty on compressor. Five-year warranty on parts. *3. Rating conditions (heating) -Indoor. D.B. 70° F (21° C), W.B. 60° F (16° C); Outdoor: D.B. 17° F (-8° C), W.B. 15° F (-9° C). "4. Indoor units receive power from outdoor units through field -supplied interconnected wiring. Specifications are subject to change without notice. visit www.MitsubishiPro.com )MITSUBISHI ELECTRIC 21 PEA/PEAD STATIC PERFORMANCE CURVES (PEA-A18AA4 MODEL SHOWN) PEA-Al2AA4 (External Static pressure 0.06 [in.WG]) 208/230V 601-1z so [0.20] 40 0.16] 3 30 [0.121 H 20 10.081 10 10.04] 0 (212] (2471 (282) (3181 (3531 1388] 1424] Airflow nee [CFM( Limit *High \ Middle • ♦ Nit Rated point • LOW PEA-Al2AA4 (External static pressure 0.14 [in.WGD 208/230V 60Hz (0.32] (028] g (0.241 5 m (0.20] [0.161 7. 10.121 10.08] [0.04] Lime R ted point' Middle .`Igh 0 (2121 .0 1247) 12821 131e1 Airflow rate ]CFM] (353] (388] [4 4] PEA-Al2AA4 (External static pressure 0.20 [in.WG]) 208/230V 60Hz 10.321 [0.28] (0241 3 $ p [0.20] a (0.161 [0.12] [0.08] (0.041 0 12 21 12 71 (2821 13 81 [3531 Airflow rate [CFM] Limh P dad point ♦ Migh • Middle Low •\ [388] (44] PEA-A18AA4 (External static pressure 0.06 (in.WG])208/230V 60Hz (0.20] 1 (0.16] I [0.12] (0.08] [0.04] Limn High .\ MktlI. Low Rated ♦ ♦ point \ (3 8] [353] (388] [424] (4591 [494] [530] (565] (600] [636] [671] AIAIOw rata CFM] PEA-A18AA4 (External static pressure 0.14 (in.WGD 208/230V 60Hz [0.32] (0.20] [0.24] 3 [0.20] 3 0 [0.16] w (0.121 [0.08] [0.04] 0 [3 8] [353] [388] [424] [4 9] (494] [530] [565] [600] [636] [671] Arnow rate [CFM] Limn Mlgh Low 10010 \, \ Rated point♦ • PEA-A18AA4 (External static pressure 0.20 [in.WG]) 208/230V 60Hz [0.32] [028] [0.24] [0.20] (0.16] E (0.12] w [0.08] [0.04] 0 [3 8] [353) [388] [424] [4 9] [494] [530] [5651 [600] [636] [671] Airflow rate ]CFM] LI mit M1911 Mlddl Rated point Low \ \ \,\ \ \ PEAD-A24AA4 (External static pressure 0.20 (in W.G.]) 208-230V 60Hz 5949 04055 0.2011 P.tml 505015 Pawl ro.0401 PI Pan : Law fm4 AA,. ma PP4] Its PEAD-A24AA4 (Externa( static pressure 0.40 [in W.G.)) 208-230V 60Hz r a PI RSA Limn 4 i 155 r 5. . A. . Prow oein 900) (1061 4.10... ICM 9401 pose! PEAD-A24AA4 (External static pressure 0.60 [n W.G.() 208.230V 60Hz I P 005 P70r1 50 p ml Rath oovn 0055 • 9101 rra01 Aural. ma lone 0005 11588 PEAD-A30AA4 (External static pressure 0.20 [in W.G.( 208-230V 60Hz 03015 pool] 0405] 1 Pmt1 9.5055 0.1281 6401 P0a61 .p. • • 1 I 10001 I>005 4vb.mlcsMl 901 PEAD-A30AA4 (External static pressure 0.40 [1n W.G.] 208-230V 60Hz ro 062 Rana pant 965 pad 100.r rawlcn4 Man ma] PEAD-A30AA4 (External static pressure 0.60 [in W.G.( 208-230V 60Hz 05061 it 000•) 1020 1 5005 1008. rm PFlu1 1.101 50 22 AMITSUBISHI ELECTRIC visit www.MitsubishiPro.cam PEAD-A36AA4 (External static pressure 0.20 [in W.G.[) 208-230V 60Hz 0./011 0.711 0:011 02311 j5 02411 ` 02011 10.1111 0.,231 100101 00101 01 0111 ;Mon t 11x11 11011 0631 110191 011ow 11.01 (CMI 00.2 .2 111891 PEAD-A36AA4 (External static pressure 0.40 [in W.G.[) 208 230V 60Hz .01i zfi 2 el 02011 00 0631 11001 11011 11631 110191 11231 11 111 1,101 012.001 !CPA • •/'. • 7!, '2 • • • 4. PEAD-A36AA4 (External static pressure 0.60 [in W.G.[) 208-230V 60Hz 01011 0011 fi 0.011 02011 01 0101 • 111 .8 • . s. 2001) 11631 (10191 110011 11 101 (1000 0232. m. 1x101 PEAD-A42AA4 (External static pressure 0.20 [in W.G.[) 208.230V 60Hz s 0.1011 103.1 1021,1 102011 02011 p.1111 0.1001 10011 00001 01 1201 • 0201 11o$11 112311 11 10 11110 AMM 123 [CPA] PEAD-A42AA4 (External static pressure 0.40 in W.G.[) 208-230V 60Hz 102 0.1 1 01911 00011 , / J 100 0231 110001 110011 I, 111 11101 0low nn ICM1 PEAD-A42AA4 (External static pressure 0.60 1n W.G.[) 208-230V 60Hz 02041 10101 ] 0.011 00011 r • 10001 1,0101 11911 1, 121 11.1 AM. .0 ICM' Ducting considerations for the PEA/PEAD Horizontal Ducted Indoor Unit With the introduction of ducted indoor unit products, some information on duct selection and design seems appropriate. Considering the performance and design of these indoor units, selection, and proper duct sizing and installation are critical elements to consider when de- signing these indoor units for satisfactory performance and installation. The maximum available static pressure from the PEA indoor unit is 0.2 in. W.G. and for the PEADs 0.6 in. W.G. Therefore ductless design is an important element to consider for delivery of proper airflow to a conditioned space. The emphasis should still be on moving refriger- ant and not air; not only will this dynamic help to work within the static pressure available, but it is also more efficient. Here are some good practices when ducting the low profile unit: • When reviewing static pressure duct loss in a system, keep in mind the maximum static pressure the unit will see. • Flexible duct work, while making installations simpler, can add unnecessary static pressure Toss if not utilized properly. Most of the static pressure duct loss comes from allowing the duct work to sag. Allowing even a 30 percent sag in the duct work can increase the static pressure loss up to eight times. Flexible duct work runs should be kept to less than 15 ft. Elbows should be kept to a minimum and made as wide as possible. . • Grilles should be selected so that the air velocity is less than 500 ft. per minute, for this prerequisite will help to minimize static pressure loss. The chart below shows grille sizes and corresponding flow rates to keep the static pressure loss under 0.05 in.: Airflow (CFM) 50 100 150 200 250 Grille Size (In. x In.) 6x6 6x6 8x6 10x6, 8x8 12x6, 10x8 • The final component is to understand what the sta is pressure loss is in the duct work. The chart below shows approx'mate static pressure loss per 100 ft. for various round duct sizes and flow rates. If flexible duct work is being used and the flex remains stretched, 20 percent can be added to the values below to approximate the loss. Inches of Static Pressure Loss per 100 ft. of Hard Duct 400 6110 8110 10"o 50 CFM 0.15 0.02 - - 100 CFM 0.6 0.08 0.02 - 150 CFM - 0.2 0.04 - 200 CFM - 0.3 0.08 0.02 250 CFM - 0.45 0.11 0.04 500 CFM - - 0.4 0.15 visit www.MitsubishiPro.com MITSUBISHI ELECTRIC 23 H2i® P -SERIES HEAT PUMP Wall -mounted models E Ceiling -cassette models Ceiling -suspended models BE TAX CREDIT rbI Model Name Cooling *1 Indoor Unit Outdoor Unit Rated Capacity Btu/h PKA-A3OKA4 PUZ-HA3ONHA2 30,000 PKA-A36KA4 PUZ-HA36NHA2 33,500 PLA-A3OBA4 PUZ-HA3ONHA2 30,000 PLA-A36BA4 PUZ-HA36NHA2 34,000 PCA-A30KA4 PUZ-HA3ONHA2 30,000 PCA-A36KA4 PUZ-HA36NHA2 34,000 Capacity Range Btu/h 18,000-30,000 18,000-34,200 18,000-30,000 18,000-36,000 18,000-30,000 18,000-36,000 Total lnput W 2,500 2,790 2,450 2,690 2,480 2,810 Energy Efficiency SEER 16.5 16.2 15.6 17 16.1 16.6 Moisture Removal Pintsrti 8.1 8.7 7.2 7.1 8.3 8.2 Sensible Heat Factor 0.70 0.71 0.73 0.71 0.69 0.73 Heating at 47° F'2 Rated Capacity Btu/h 32,000 38,000 32,000 38,000 32,000 38,000 Capacity Range Btu/1i 18,000-34,000 18,000-40,000 18,000-34,000 18,000-40,000 18,000-34,000 18,000-40,000 Total Input W 2,930 3,410 3,440 3,230 2,990 3,270 HSPF (IV) Btu/h/W 9.5 10 9.4 10 9.3 10.3 Heating at 17° F'3 Rated Capacity Btu/h 19,000 25,000 19,000 28,000 19,000 27,000 Rated Total Input • W 2,570 3,330 2,710 3,590 2,830 3,490 Maximum Capacity Btu/h 32,000 38,000 32,000 38,000 32,000 38,000 Maximum Total Input W 5,080 6,010 5,720 5,300 5,170 5,720 Heating at 5° F'4 Maximum Capacity Btu/1i 32,000 38,000 32,000 38,000 32,000 38,000 Maximum Total Input W 5,770 6,760 6,630 5,860 5,830 6,550 Power Supply Phase, Cycle, Voltage 1 -phase, 60Hz, 208/230V *5 Voltage Indoor - Outdoor S1 - S2 AC208 / 230V Indoor - Outdoor S2 - S3 DC24V Indoor Unit MCA A 1 2 1 2 Fan Motor F.L.A. 0.36 1 0.57 0.51 1.00 0.54 0.97 Fan Motor Output W 56 50 120 95 160 Airflow (Lo -Mid -Hi or Lo-Mid1- Mid2-H) DRY (CFM) 635-705-775 705-810-920 490-570-640-740 710-810-920-1,060 565-600-635-705 775-850-920-990 WET (CFM) 570-635-700 635-730-830 460-530-600-710 670-770-880-1,030 530-565-600-670 705-775-850-920 Sound Pressure Level (Lo -Mid -Hi or Lo-Midi-Mid2-H0 dB(A) 39-42-45 43-46-49 28-30-32-34 32-34-37-40 35-37-39-41 37-39-41-43 External Finish Color Munsell No. 1 OY 9 2 / 0.2 Munsell No 6 4Y 8.9 / 0 4 (Grille) Munsell No 6 4Y 8 9 / 0 4 Dimension Unit W: In. 46-1/16 33-1/16 (Grille: 37-3/8) 50-3/8 63 O: In. 11-5/8 33-1/16 (Grille: 37-3/8) 26-3/4 H: In. 14-3/8 10-3/16 (Grille: 1-3/8) 11-3/4 (Grille 1-3/8) 9-1/16 Weight Unit Lbs. 46 51 (Grille: 13) 55 (Grille: 13) 71 1 79 Drain Lift Mechanism (Included) H: In. N/A 33-7/16 N/A Field Drainpipe Size In. 5/8 I.D. 1-1/4 0.D. 1-1/16 0.D. Outdoor Unit MCA A 28 Recommended Fuse/Breaker A 30 MOCP A 40 Fan Motor F.L.A. 0.4 + 0.4 Fan Motor Output W 60 + 60 Compressor Model (Type) INVERTER R.L.A. 18 L.R.A. 27.5 Airflow CFM 3,530 Refrigerant Control Electronic Expansion Valve Defrost Method Reverse Cycle Sound Pressure Level at Cooling *1 dB(A) 52 Sound Pressure Level at Heating *2 dB(A) 53 External Finish Color Munsell No. 3Y 7.8 / 1.1 Dimensions W: In. 37-3/8 0: In. 13 + 1-3/16 H: In. 53-1/8 Weight Lbs. 265 Refrigerant Type R410A Charge Lbs. 12 Oil Type (fl. oz.) FV5OS (45) Refrigerant Pipe Gas Side O.D. In. 5/8 Liquid Side 0.0. In. 3/8 Refrigerant Pipe Length Height Difference (Max.) Ft. 100 Length (Max.) Ft. 245 Connection Method Indoor/Outdoor Flared/Flared Operating Temperature Range Cooling 0° F D.B. to 115° F D.B. with Wind Baffle Accessory Installed Heating -13° F W.B. to +59° F W.B. Notes: *1. Rating conditions (coo ing)-Indoor: D.B. 26.7° C (80° F), W.B. 19.4° C (67° F); Outdoor: D.B. 35° C (95° F), W.B. 23.9° C (75° F). *2. Rating conditions (heating) -Indoor. D.B. 21.1° C (70° F), W.B. 15.6° C (60° F); Outdoor. D.B. 8.3° C (47° F), W.B. 6.1° C (43° F). 24 ).MITSUBISHI ELECTRIC *3. Rating conditions (heating) -Indoor: D.B. 21.1° C (70° F), W.B. 15.6° C (60° F); Outdoor: D.B. -8.3° C (17° F), W.B. -9.4° C (15° F). *4. Rating conditions (heating) -Indoor. D.B. 21.1° C (70° F), W.B. 15.6° C (60° F); Outdoor: D.B. -15° C (5° F), W.B. -15° C (5° F). visit www.MitsubishiPro.com *5. Indoor units receive power from outdoor units through field -supplied interconnected wiring. LIMITED WARRANTY I Seven-year warranty on compressor. Five-year warranty on parts. Specifications are subject to change without notice. H2i° P -SERIES HEAT PUMP IWIERTfR Model Name Indoor Unit Outdoor Unit PEAD-A30AA4 PUZ-NA30NHA2 PEAD-A36AA4 PUZ-HA36NHA2 Cooling *1 Rated Capacity Btu/h 30,000 34,000 Capacity Range Btu/h 18,000-30,000 18,000-36,000 Total Input W 2,500 2,800 Energy Efficiency SEER 16.5 16.8 Moisture Removal Pints/h 8.9 7.3 Sensible Heat Factor 0.67 0.76 Heating at 47° F'2 Rated Capacity Btu/h 32,000 38.000 Capacity Range Btu/h 18,000-34.000 18.000-40,000 Total Input W 2,750 3,150 HSPF (IV) Btu/h/W 9.5 10.4 Heating at 17° F'3 Rated Capacity Btu/h 19,000 27,000 Rated Total Input W 2,590 3,250 Maximum Capacity Btu/h 32,000 38,000 Maximum Total Input W 4,930 5,400 Heating at 5° F'4 Maximum Capacity Btu/h 32,000 38,000 Maximum Total Input W 5,420 6,100 Power Supply Phase, Cycle, Voltage 1 Phase, 60Hz, 208/230V *5 Voltage Indoor - Outdoor St - S2 AC 208 - 230V Indoor - Outdoor S2 - S3 DC24V Indoor - Remote Controller DC12V: For Wired Controller Indoor Unit MCA A 2.73 3-30 Fan Motor FLA 2.18 2 64 Fan Motor Output W 0.121 0.244 Airflow (Lo -Mid -Hi) DRY (CFM) 618-742-883 847-1,024-1,201 WET (CFM) 565-671-812 777-953-1,130 External Static Pressure *6 In WG 014 - 0 20 - 0 28 - 0.40 - 0 60 Sound Pressure Level (Lo -Mid -Hi) dB(A) 30-34-39 33-38-42 External Finish Color Galvanized -steel Sheets Dimension Unit W: In. 4.3-5/16 1 55-1/8 D. M. 28-7/8 H In. 9-7/8 Weight Unit Lbs 73 1 91 Drain Lift Mechanism (Included) H: In. 27-9/16 Field Drainpipe Size In 1-1/4 Outdoor Unit MCA A 28 Recommended Fuse/Breaker A 30 MOCP A 40 Fan Motor F L.A. 0.4 + 0.4 Fan Motor Output W 60 + 60 Compressor Model (Type) INVERTER -driven Scroll R.L.A. 18 LRA 27.5 Airflow CFM 3,530 Refrigerant Control Electronic Expansion Valve Defrost Method Reverse Cycle Sound Pressure Level at Cooling *1 dB(A) 52 Sound Pressure Level at Heating *2 dB(A) 53 External Finish Color Munsell No. 3Y 7.8 / 1.1 Dimensions W: In. 37-3/8 D: In. 13 + 1-3/16' H: In. 53-1/8 Weight Lbs. 265 Remote Controller Type Wired Refrigerant Type R410A Charge Lbs. 12 Oil Type (fl. oz.) FV50S (45) Refrigerant Pipe Gas Side 0.0. In. 5/8 Liquid Side 0 D In 3/8 Refngerant Pipe Length Height Difference (Max) Ft 100 Length (Max.) Ft 245 Connection Method Indoor/Outdoor Flared/Flared Operating Temperature Range Cooling 0° F D.B. to 115° F with Wind Baffle Accessory Installed Heating -13° F W.B to +59° F W.B. Notes: 1. Rating conditions (cooling) -Indoor: D.B. 26.7° C (80° F), W.B. 19.4° C (67° F); Outdoor. D.B. 35° C (95° F), W.B. 23.9° C (75° F). *2. Rating conditions (heating) -Indoor: D.B. 21.1° C (70° F), W.B. 15.6° C (60° F); Outdoor: D.B. 8.3° C (47° F►, W.B. 6.1° C (43° F). Horizontal ducted models "3. Rating conditions (heating) -Indoor. D.B. 21. ° C (70° F), W.B. 15.6° C (60° F); Outdoor: D.B. -8.3° C ( 7° F), W.B. -9.4° C (15° F). *4'. Rating conditions (heating) -Indoor. D.B. 21.1° C (70° F), W.B. 15.6° C (60° F); Outdoor. D.B. -15° C (5° F), W.B. -15° C (5° F). visit www.MitsubishiPro.com "5. Indoor units receive power from outdoor units through field -supplied interconnected wiring. *6. External static pressure Is factory set to 0.20° WG. LIMITED WARRANTY I Seven-year warranty an compressor. Rve-year warranty on parts. %MITSUBISHI ELECTRIC 25 CONTROLLERS MHK1 Remote Controller Kit Exclusive for INVERTER -driven Mr. Slim® Systems MRCH1 WIRELESS REMOTE CONTROLLER • Features backlit, easy -to -read display • Is compatible with MCCH1 Portable Central Controller • Is enabled with RedLINKTM reliability MFH1 WIRELESS RECEIVER • Required for MRCH1 Wireless Remote Controller • Incorporates ual setpoint control with system changeover • Enabled with RedLINK reliability Wireless Technology Wireless Remote Controller Wireless Receiver Function ON/OFF Description ON/OFF operation for a single indoor unit Operation Mode Cool / Drying / Auto / Heat / Fan only Available operation modes dependent on connected system. Temperature Setting Set temperature from 50° F - 87° F depending on operation mode and connected system System Changeover Deadband Value 2-8° F Schedule Operation 5-2, 5-1-1 Fan Speed Setting Hi/Mid-2/Mid-1/Low/Auto Available fan speed settings dependent on connected system. Airflow Direction Setting Airflow angles: 100° - 80° - 60° - 40° and oscillate Available airflow direction settings dependent on connected system. Permit/Prohibit Function Individual prohibit operations for each remote controller function (ON/OFF, Set Temperature, and Operation Mode). Space Temperature Displays the measured space temperature. Error Indication Displays error code. Display Outside Temperature and Humidity Requires optional MOS1 Outside Air Sensor Dimensions - (W x D x H) Remote Controller: 5-3/16" x 1-1/2" x 3-9/16" Receiver: 3-1/4" x 1-5/16" x 6-7/16" Operating Ambient Temperature Remote Controller: 32 - 120° F Receiver: -40 - 165° F Operating Ambient Humidity Remote Controller: 5% - 90% RH (non -condensing) Receiver: 5% - 9% RH (non -condensing) Power Supply 2 AA batteries MHK1 Kit includes MRCH1 Wireless Wall -Mounted Remote Controllers MFH1 Wireless Receiver and Cable MRC1 Cable Install and Operation Manual 26 :MITSUBISHI ELECTRIC Accessories MCCH1 Portable Central Controllers MOS1 Outside Air Sensor visit www.MitsubishiPro.com CONTROLLERS MCCH1 Portable Central Controller Exclusive for INVERTER -driven Mr. Slim® Systems • Has up to 16 Zones • Works with MRCH1 Wireless Remote Controller • Is able to monitor and control ON/OFF, Mode, Set Temperature • Enables schedule overrides • Can view Outside Aair temperature and humidity with optional MOS1 Outside Air Sensor • Features backlit easy -to -read display • Is compatible with other RedLINKTM devices • Does not interfere with other wireless devices 4)) Wireless Technology Function ON/OFF Description Offers ON/OFF operation for up to 16 individual indoor units Operation Mode Cool / Auto / Heat Offers available operation modes dependent on connected system Temperature Setting Has capability to set temperature from 50° F — 87° F depending on operation mode and connected system Space Temperature Displays the measured space temperature individually per indoor unit Error Indication Displays error code Display Outside Temperature and Humidity Requires optional MOS1 Outside Air Sensor Dimensions - (W x D x H) 3-1/8" x 1-5/8" x 6-1/4" Operating Ambient Temperature 32 - 120° F Operating Ambient Humidity 5% - 90% RH (non -condensing) Power Supply 3 AA batteries Requires MHK1 (Remote Controller and Receiver) per indoor unit. Accessories MOS1 Outside Air Sensor visit www.MitsubishiPro.com .:MITSUBISHI ELECTRIC 27 CO\TROLLFRS Set Temperature Timer Menu Mode Set Time PAR -21 MAA Wired Controller Timer ON/OFF— Wired controller for the indoor unit. (multi-lingual) ON/OFF Fan Speed Filter Test Run Check Airflow UP/DOWN Louver Ventilation Function ON/OFF Description ON/OFF operation for group of up to 16 indoor units Operation Mode Cool / Dry / Auto / Heat / Fan only Available operation modes dependent on connected system Temperature Setting Set temperature from 50° F — 87° F depending on operation mode and connected system Timer Operation 7 day timer (ON/OFF, Set Temperature) Fan Speed Setting Hi/Mid-2/Mid-1/Low/Auto Available fan speed settings dependent on connected system Airflow Direction Setting Airflow angles: 100° - 80° - 60° - 40° and oscillate Available airflow direction settings dependent on connected system Permit/Prohibit Function Individual prohibit operations for each remote controller function (ON/OFF, Set Temperature, Operation Mode, and Filter reset) Space Temperature Measured space temperature displayed Error Indication Error code displayed Dimensions - (W x D x H) 5-1/8" x 3/4" x 4-3/4" 28 ..MITSUBISHI ELECTRIC visit www.MitsubishiPro.com CONT ROLLERS Hand-held IR Wireless Controller Function ON/OFF Description ON/OFF operation for a single indoor unit Operation Mode Cool / Dry / Auto / Heat / Fan only Available operation modes dependent on connected system. Temperature Setting Set temperature from 50° F, — 87° F depending on operation mode and connected system Timer Operation ON/OFF timer Fan Speed Setting Hi/Mid-2/Mid-1/Low/Auto Available fan speed settings dependent on connected system. Airflow Direction Setting Airflow angles: 100° - 80° - 60° - 40° and oscillate Available airflow direction settings dependent on connected system. Permit/Prohibit Function Individual prohibit operations for each remote controller function (ON/OFF, Set Temperature, Operation Mode, and Filter reset). Space Temperature Displays the measured space temperature. Dimensions - (W x D x H) 5-1/8" x 3/4" x 4-3/4" Power Supply 2 AAA batteries visit www.MitsubishiPro.com AMITSUBISHI ELECTRIC 29 iFMT H2I P -SERIES (PUZ-HA-2) OPERATING CONDITIONS COOLING HEATING MAXIMUM MINIMUM MAXIMUM MINIMUM INDOOR INTAKE AIR TEMPERATURE 90° F D.B., 73° F W.B. 66° F D.B., 59° F W.B. 83° F D.B. 63° F D.B. OUTDOOR INTAKE AIR TEMPERATURE 115° F D.B. 0° F D.B.* 70° F D.B., 59° F W.B. -13° F D.B., -13° F W.B. With wind baffle accessary installed. Without wind baffle Installed, the minimum temperature will be 23° F D.B. P -SERIES (PUY/PUZ-4) OPERATING CONDITIONS COOLING HEATING MAXIMUM MINIMUM MAXIMUM MINIMUM INDOOR INTAKE AIR TEMPERATURE 95° F D.B., 71° F W.B. 67° F D.B., 57° F W.B. 80° F D.B., 67° F W.B. (PUZ-A) 70° F D.B., 60° F W.B. (PUZ-A) OUTDOOR INTAKE AIR TEMPERATURE 115°FD.B. 0° F D.B.* 70° F D.B., 59° F W.B. (PUZ-A) 12° F D.B., 10° F W.B. (PUZ-A) With wind baffle accessory installed. Without wind baffle Installed, the minimum temperature will be 23° F D.B. REFRIGERANT TUBING SETS Lineset Model Number MLS141212T-15 MLS141212T-30 MLS141212T-50 MLS141212T-65 MLS141212-100 MPLS385812T-10 MPLS385812T-15 MPLS385812T-30 MPLS385812T-50 MPLS385812T-65 MPLS385812T-100 Tube Length Insul. Size (In.) Ft. URI MEI EEO LSI 111151 ®® 111131 Ell 1/4 x 1/2 1/4 x 1/2 30 1/4 x 1/2 50 1/4 x 1/2 65 1/4 x 1/2 100 3/8 x 5/8 3/8 x 5/8 3/8 x 5/8 10 30 3/8 x 5/8 50 3/8 x 5/8 65 3/8 x 5/8 100 Use With Mitsubishi Electric Models PKA-Al2,18HA4; PLA-Al2,18BA4; PEA-Al2, Al 8AA4 PKA-A24,30,36KA4; PLA-A24,30,36,42BA4; PCA-A24,30,36,42KA4; PEAD-A24-42AA4 OPTIONAL ACCESSORIES REFRIGERANT LINE LENGTH FLARE/FLARE INDOOR UNIT PKA-Al2HA4 OUTDOOR UNIT PUY-Al2NHA4 LENGTH IN FEET 100 HEIGHT IN FEET 100 PKA-A18HA4 PUY/Z-A18NHA4 100 100 PKA-A24KA4 PUY/Z-A24NHA4 165 100 PKA-A3OKA4 PUY/Z-A3ONHA4 165 100 PKA-A3OKA(H2) PUZ-HA3ONHA2 245 100 PKA-A36KA4 PUY/Z-A36NHA4 165 100 PKA-A36KA (H2i) PUZ-HA36NHA2 245 100 PLA-Al2BA4 PUY-Al2NHA4 100 100 PLA-A18BA4 PUY/Z-A18NHA4 100 100 PLA-A24BA4 PUY/Z-A24NHA4 165 100 PLA-A3OBA4 PUY/Z-A3ONHA4 165 100 PLA-A3OBA (H2i) PUZ-HA3ONHA2 245 100 PLA-A36BA4 PUY2-A36NHA4 165 100 PIA-A36BA (H2i) PUZ-HA36NHA2 245 100 PLA-A42BA4 PUY/Z-A42NHA4 165 100 PCA-A24KA4 PUY/Z-A24NHA4 165 100 PCA-A3OKA4 PUY/Z-A3ONHA4 165 100 PCA-A30KA(H2i) PUZ-HA3ONHA2 245 100 PCA-A36KA4 PUY/Z-A36NHA4 165 100 PCA-A36KA (H2i) PUZ-HA36NHA2 245 100 • PCA-A42KA4 PUY/Z-A42NHA4 165 100 PEA-Al2AA4 PUY-Al2NHA4 100 100 PEA-A18AA4 PUY/Z-A18NHA4 100 100 (2)PEA-A18AA (1-121) PUY/Z-HA36NHA2 245 100 PEAD-A24AA4 PUY/Z-A24NHA4 165 100 PEAD-A30AA4 PUY2-A3ONHA4 165 100 PEAD-A30AA(H2) PUZ-HA3ONHA2 245 100 PEAD-A36AA4 PUY/Z-A36NHA4 165 100 PEAD-A36AA (H2i) PUZ-HA36NHA2 245 100 PEAD-A42AA4 PUY/Z-A42NHA4 165 100 PART NUMBER PAC-SH84DM-E USE WITH PCA-A**KA DESCRIPTION Pum ' s Mitsubishi pump kit SI1730-230 P -Series - 30,000 Btu/11 or greater Sauermann® mini condensation pump: 230V SI3100-230 P -Series - Less than 30,000 Btu/h Sauermann® mini condensation pump: 230V Miscellaneous BRP -1 Bottom Return Plate for SEZ-KD09NA Converts low profile ducted indoor unit from rear retum to bottom return BRP -2 Bottom Return Plate for PEA-Al2AA Converts low profile ducted indoor unit from rear return to bottom return BRP -3 Bottom Return Plate for PEA -A1 8AA Converts low profile ducted indoor unit from rear return to bottom return BV12FSI Use with any Mr. Slim multi -zone product Refrigeration Ball Valve-Flare/Schrader®/Insulated -1/2" BV14FSI Use with any Mr. Slim multi -zone product Refrigeration Ball Valve-Flare/Schrader®/Insulated -1/4" BV38FSI Use with any Mr. Slim multi -zone product Refrigeration Ball Valve-Flare/Schrader®/Insulated - 3/8" BV58FSI Use with any Mr. Slim multi -zone product Refrigeration Ball Valve-Flare/Schrader®/Insulated - 5/8" CWMB1 PU outdoor units Condensing unit wall mounting brackets (set of 2) - 440 Ib. capacity: painted steel NOTE: Installer is responsible to select and provide suitable hardware and materials to insure proper mount of bracket to wall. DSD -400N P -Series DiamondBackTM Platform Stands PAC-SG58SG-E P -Series Air outlet guide (1 piece) PUY/Z-Al2/A18 PAC SG59SG E P -Series Air outlet guide (1 piece) PUY/Z-A24/A30/A36/A42 (42 installation requires 2 pieces); PUZ-HA36NA (Requires 2 pieces) PAC-SG61DS-E PUZ(Y)-A42 Drain socket -connector PAC-SG63DP-E PUZ(Y)-Al2/18 Drain pan PAC-SG64DP-E PUZ(Y)-A24/30/36/42 / PUZ-HA36 Drain pan PAC-SH51 SP -E All PLA -ABA Models Air outlet shutter plates (1 set = 2 pieces) PAC-SH53TM-E All PLA -ABA Models Multi -function casement (High -efficiency filter element not included) RCMKP1 CB P -Series Wireless Lockdown bracket for remote controller ULTRILITE1 PUZ(Y)-Al2/18 Condensing unit mounting pad: 16" x 36" x 3" ULTRILITE2 PUZ(Y)-A24/30/36/42; PUZ-HA30, 36 Condensing unit mounting pad: 24" x 42" x 3" 30 AMITSUBISHI ELECTRIC *49' and 66' applies to installations In which the outdoor unit is installed below Indoor unit visit www.MitsubishiPro.com OPTIONAL ACCESSORIES (CONT.) PART NUMBER USE WITH DESCRIPTION MSDD-50SR-E Port Adapters P -Series and Connection Pipes Twinning distribution pipe PAC-SC84PI-E PKA-Series (A24/30/36/42) L connector pipe (for left side piping) Control Options and Accessories CN24RELAY-KIT-CM3 PLA -BA, PCA -KA, PEA -AA indoor units External heater relay kit and adapter for CN24 connector and control PAC-715AD P -Series Connector for CN32 (for remote on/off) PAC 725AD P -Series / PKA-HAIL)/KA(L) indoor units Connector for CN51/multiple remote controller adapter - status/signal output and duct/supply fan controller (PLA/PCA), External Heater Control for CN152 PAC-SA1 ME -E i -see"' sensor for PLA -ABA i -see sensor corner panel for PLA -ABA indoor units PAC-SE41 TS -E P -Series indoor units Remote temperature sensor for P -Series indoor units PAC-SE55RA-E P -Series Remote operation adapter: CN32 Remote on/off PAC-SE57RA-E PLA / PKA / PCA Remote operation adapter: CN30 LLC PAC-SE59RA-E P -Series Remote operation adapter: display and OWOFF PAC-SF4ORM-E P -Series Remote operation adapter: display and on/off PAC-SF81 MA -E PUY-A, PUZ-A, and PUZ-HA M -NET control adapter for Mr. Slim PUY-A, PUZ-A, and PUZ-HA outdoor units PAC-SH91 MK -E i -see sensor for PCA i -see sensor in mounting panel for PCA indoor units PAC-SK52ST P -Series Service Tool Control / Service tool w/display for P -Series systems - Connects to outdoor unit • PAC-YU25HT PEA, PEAD indoor units External fan / Heater control relay adapter PAR -21 MAA -G Use with P -Series Deluxe MA remote controller (Requires MAC -3971F -E for use with M -Series - MSY/Z, MFZ) MHK1 All P -Series and SEZ, SLZ 1:1 Systems RedLINKTM Enabled Remote Controller Kit with MRCH1 controller, MIFH1 receiver, and MRC1 cable MCCH1 MHK1 Portable central controller; works with MHK1 PAR-FL32MA PLA / PEA / PEAD / SEZ Wireless remote controller for PLA -BA, PEA -A, PEAD-AA units (Requires signal receiver PAR-SA9FA- E) PAR-SA9CA-E PEA, PEAD and PKA Wireless signal receiver for PEA, PEAD, and PKA units (For PAR-SL32MA controller) PAR-SA9FA-E PLA -ABA Wireless signal receiver for PLA -BA units (For PAR-SL32MA controller) PAR-SA92MW-E PCA wireless controller kit with i -see sensor Wireless remote controller kit with i -see sensor for PCA PAR-SL93B-E PCA Wireless controller kit Wireless remote controller kit for PCA PZ -41 SLB -E Lossnay Lossnay ERV remote controller for LGH ERV control RG78G358G18 PKA (L) models Connector for CN -22 to add wired controller - PAR -21 MAA -G to PKA(L) wireless models Low Ambient WB-PA1 P -Series Wind baffle (1 piece) PUY/Z-Al2/A18 WB-PA2 P Series Wind baffle (1 piece) PUY/Z-A24/A30/A36/A42 (42 installation requires 2 pieces); PUZ-HA30 and 36NA (Requires 2 pieces) visit www.MitsubishiPro.com AMITSUBISHI ELECTRIC 31 DIAMONDBACK' Ball Valves Model numbers: BV14FFSI BV38FFSI BV12FFSI BV58FFSI c us LISTED 891N REFRIGERANT VALVE • Sizes available: 1/4"; 3/8"; 1/2"; 5/8" • Fully factory assembled • Furnace brazed and pressure tested • Each ball valve is equipped with Schrader® valve for refrigerant service • Design working pressure: 700 PSIG • Temperature range: -40° F to +325° F (-40° C to +149° C) • Forged brass body andseal cap • Polytetrafluroethylene seals and gaskets (no synthetic O -rings) • Seal cap design permits valve operation without removal of seal cap • Uses suitable for with R-11, R-22, R-123, R-125, R -134A, R-236FA, R -4202A, R -402B, R -404A, R -407C, R -410A, R-500, R-502, and R-507 • One year limited materials and workmanship warranty on ball valves Teflon® is a registered trademark of E.I. du Pont de Nemours and Company Schrader® is a registered trademark of Schrader — Bridgeport Inc. • Engineered for Mini -split and Multi -split HVAC Units • Full Port Design • 700 PSIG Rated • R -410A Compatible • Flare Connections Part Number SAE Flare A BCD E F BV14FFSI 1/4" 6.19 2.60 1.80 1.22 1.42 1.10 BV38FFSI 3/8" 6.30 2.67 1.80 1.22 1.42 1.10 BV12FFSI 1/2" 6.51 2.67 1.80 1.22 1.42. 1.10 BV58FFSI 5/8" 6.64 2.67 1.80 1.28 1.42 1.10 'Ballvalves come with an insulation piece � L 32 ..MITSUBISHI ELECTRIC DIAMONDBACK" (gg Platform Stands Lift the Mitsubishi Electric Comfort Solution outdoor unit to new heights with our Diamondback Platform Stands. • Is easy to install • Available for all sizes of Mr. Slim outdoor units • Is color matched to the outdoor units Model Number: DSD -400N L: 15-3/4" x W: 3-1/4" x H: 3-1/4" visit www.MitsubishiPro.com DIAMONDBACK'"' LINESET (+ Caps on Caps off with flared ends exposed I 00 Lineset Model Number MLS141212T-30 Tube Size (In.) 1/4 x 1/2 Length Ft. 30 Insul. 1/2" MLS141212T-50 1/4 x 1/2 50 1/2" MLS141212T-65 1/4 x 1/2 65 1/2" MLS141212T-100 1/4 x 1/2 100 1/2" MLS145812T-15 1/4 x 5/8 15 1/2" MLS145812T-30 1/4 x 5/8 30 1/2" MLS145812T-50 1/4 x 5/8 50 1/2" MLS145812T-65 1/4 x 5/8 65 1/2" MLS145812T-100 1/4 x 5/8 100 1/2" MPLS385812T-10 3/8 x 5/8 10 1/2" MPLS385812T-15 3/8 x 5/8 15 1/2" MPLS385812T-30 3/8 x 5/8 30 1/2" AMPLS385812T-50 3/8 x 5/8 50 1/2" MPLS385812T-65 3/8 x 5/8 65 1/2" MPLS385812T-100 3/8 x 5/8 100 1/2" Diamondback advantages include the following features: • Quick, efficient, and economical field installation using factory -applied Twin Tube insulation and flare connections with flare nuts mounted • Correct lengths for reducing waste and time • Quality, consistency, and economy • Testing of all Diamondback Lineset tubing is tested in accordance with ASTM E243 Twin -Tube Lineset Insulation Design • Balanced outside diameter for uniform coil/uncoil position stability • Minimum 1/2" insulation thickness on both tubes Filter Boxes FB Series filter boxes are available in compatible sizes for all Mr. Slim horizontal ducted indoor units. FBL1 filter boxes include 1" thick -pleated MERV 8 filter(s), and FBM2 boxes include 2" thick -pleated MERV 13 filter(s) installed. Filters are tested in accordance with ANSI/ASHRAE Standard 52.2 and rated Class 2 under U.L. Standard 900. FBL1-1 FB Series Filter Box for SEZ-KDO9N FBL1-2 FB Series Filter Box for SEZ-KD12,KD15-NA, and PEA-Al2AA FBL1-3 FB Series Filter Box for SEZ-KD18NA and PEA-A18M FBM2-3 FB Series Filter Box for PEAD-A24,30AA FBM2-4 FB Series Filter Box for PEAD-A36,42AA The cabinet is constructed of non -insulated 20 gauge G-60 galvanized steel with foam gasket and provides an airtight connection to indoor unit and access door. Gasket material complies with UL 723 requirements. A screw -through cabinet design for secure attachment to indoor unit and return connection in rear is easily field -converted to bottom return. visit www.MitsubishiPro.com AMITSUBISHI ELECTRIC 33 Put a professional finish on air-conditioning installations with an easy -to -install modular system that beautifies exteriors and protects linesets, drainlines, and wiring. • Can be used indoors, too! Meets UL94v-0 for interior applications • Has snap -on covers and a full selection of couplings, elbows, T -joints, caps, and more for any application: complex or simple • Offers high-quality PVC with UV inhibitors for outdoor service in all weather conditions • Can be painted with most house paints to match exterior decors • Is not just for HVAC. Hides any exterior cabling, piping, or wiring • Is available in four sizes: 2-1/4", 3", 4", and 6" tubes Download a brochure at www.line-hide.com to find out more information. AMrrsusi l ELEC RIC Model CFM Model CFM LGH-F300RX3-E 300 LGH-F470RX3-E 470 LGH-F600RX3-E 600 LGH-F1200RX3-E 1,200 Improved sound attenuation makes Lossnay® units quiet enough for places where silence is a must such as meeting rooms and libraries. A free -cooling function is standard to help reduce costs and boost efficiency. The integrated bypass damper design makes installation and system management quick and efficient. Lossnay models offer three ventilation modes: • Energy Recovery - Heat Exchange • Bypass - No Exchange • Automatic - Heat Exchange/Bypass 34 :.MITSUBISHI ELECTRIC visit www.MitsubishiPro.com M -SERIES 1NVERTER-d riven • MITSUBISHI M ELECTRIC i..t<44,',3 ON: $1,10114 504.0gorg CITY MULTI® Variable Refrigerant Flow • MITSUBISHI 4/111ELECTRIC Cj4J qrly INVERTER-dnven Split -Ductless Comfort Systems M- Series Full Line Catalog For more information on our INVERTER -driven product line visit our website at www.mitsubishipro.com Variable Refrigerant Flow Zoning Systems: 3-30 Tons For more information on our CITY MULTI VRF product line visit our website at www.mitsubishipro.com visit www.MitsubishiPro.com ...MITSUBISHI ELECTRIC 35 COOLING & HEATING Mitsubishi Electric Advanced Products Division 3400 Lawrenceville Suwanee Road, Suwanee, GA 30024 Phone: 888-467-7546 Fax: 800-658-1458 M2011 Mitsubishi Electric & Electronics USA, Inc. Mr Slim and H2i are registered tradernarks of Mitsubishi Electric. The three -diamond logo is a registered logo of Mitsubishi Electric Corporation. 'Hyper -Heating technology Patent Pending. RedLINK and RedLINK wireless technology logo are a registered trademark of Honeywell International See complete warranty for terms, conditions, and limitations. A copy is available from Mitsubishi Electric_ FormNo. PSERIES 5-11 40K OA (reprint) For more information visit www.mitsubishipro.com Mixed Sources (A �i CERTIFIED,. P:rdut group from well-managed fri esis .and c cher controlled sources FSC ENERGY STAR PARTNER facebook.com/mehvac twitter.com/m€tsub€sh€hvac You Tube youtube.com/mitsubishihvac Please Recycle MIT OP,F3D PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-110 DATE: 06/18/13 PROJECT NAME: CASCADE VIEW ELEMENTARY SITE ADDRESS: 13601 32 AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: b1-- J Al Building Division Public Works Awe Fire Previon Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) DUE DATE: 06/20/13 Complete tg] Incomplete ❑ Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Routet5-41 Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/18/13 Approved ❑ Approved with Conditions k Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Prater Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LaI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name MCKINSTRY CO LLC UBI No. 602569922 Phone 2067623311 Status Active Address Po Box 24567 License No. MCKINCL942DW Suite/Apt. License Type Construction Contractor City Seattle Effective Date 3/16/2006 State WA Expiration Date 3/16/2014 Zip 98134 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status LYDIGML901JLLYDIG+ MCKINSTRY LLC Construction Contractor General Unused 4/13/2010 4/13/2014 Active WESTVI'121RF WESTVENT INC Construction Contractor General Unused 12/6/1988 9/1/1994 Archived MCKIN**372ND MCKINSTRY CO Construction Contractor General Unused 8/20/1963 1/2/2008 Re Licensed Business Owner Information Name Role Effective Date Expiration Date PEDERSEN, JAMIE D Agent 03/16/2006 Bond Amount ALLEN, DEAN CHARLES Partner/Member 03/16/2006 929519469 MOORE, DOUGLAS JAMES Partner/Member 03/16/2006 ALLEN, DAVID EDWARD Partner/Member 03/16/2006 WESTERN SURETY CO TEPLICKY, JOSEPH WILLIAM Partner/Member 03/16/2006 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 3 Western Surety Co 929519469 03/01/2011 Until Cancelled 01/23/2012 $12,000.00 02/24/2011 2 WESTERN SURETY CO 929511574 09/09/2010 Until Cancelled $12,000.00 09/02/2010 1 TRAVELERS CAS & SURETY CO 104702039 01/03/2006 Until Cancelled 03/01/2011 $12,000.00 03/16/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 6 Zurich American Ins Co GLA 3999903 01/31/2013 01/31/2014 $2,000,000.00 01/02/2013 5 Zurich American Ins Co GLA 3999903 01/31/2012 01/31/2013 $2,000,000.00 12/16/2011 4 ZURICH AMERICAN INS CO GLA3999903 01/31/2011 01/31/2012 $2,000,000.0012/20/2010 3 ZURICH AMERICAN INS CO CP0399990301 01/31/2009 01/31/2011 $2,000,000.00 12/07/2009 2 CP03999903 01/31/2008 01/31/2009 $2,000,000.00 01/31/2008 httns://fortress.wa.gov/lni/bbip/Print.aspx 06/27/2013