Permit M13-112 - TUKWILA DELI - INSTALL KITCHEN HOOD
TUKWILA DELI 13028 INTERURBAN AVE S EXPIRED 01/18/14 M13-112 Cil oAukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov Parcel No.: 0004800017 Address: 13028 INTERURBAN AV S TUKW Project Name: TUKWILA DELI MECHANICAL PERMIT Permit Number: M13-112 Issue Date: 07/22/2013 Permit Expires On: 01/18/2014 Owner: Name: EPROPERTY TAX INC DEPT #207 Address: PO BOX 4900 , SCOTTSDALE AZ 85261 Contact Person: Name: MARK CHANG Address: 33124 41 LN S , FEDERAL WAY WA 98001 Email: MARKYONGC@YAHOO.COM Contractor: Name: JD CONSTRUCTION Address: 15227 34 DR SE , MILL CREEK WA 98012 Contractor License No: JDCONC*89KU Phone: 206-229-3557 Phone: 206-446-5759 Expiration Date: 05/31/2015 DESCRIPTION OF WORK: INSTALL NEW TYPE I KITCHEN HOOD Value of Mechanical: $10,500.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: I hereby certify that I have read and governing this work will be complie xami with, Fees Collected: $318.31 International Mechanical Code Edition: 2009 Date: ed this permit and know the same to be true and correct. All provisions of law and ordinances whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: f7 Date:] zZ�� This permit shall become null and void if the work is not ommenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. RA11_11') Prinrarl• n7 -99-9n11 PERMIT CONDITIONS Permit No. M13-112 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: The special inspections for steel elements of buildings and structures shall be required. All welding shall be done by a Washington Association of Building Official Certified welder. 6: When special inspection is required, either the owner or the registered design professional in responsible charge, shall employ a special inspection agency and notify the Building Official of the appointment prior to the first building inspection. The special inspector shall furnish inspection reports to the Building Official in a timely manner. 7: A final report documenting required special inspections and correction of any discrepancies noted in the inspections shall be submitted to the Building Official. The final inspection report shall be prepared by the approved special inspection agency and shall be submitted to the Building Official prior to and as a condition of final inspection approval. 8: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 9: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 10: Manufacturers installation instructions shall be available on the job site at the time of inspection. 11: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 12: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 13: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 14: ***FIRE DEPARTMENT CONDITIONS*** • 15: A Type 1 hood shall be installed at or above all commercial cooking appliances and domestic cooking appliances used for commercial purposes that produce grease vapors. Each required commercial kitchen exhaust hood and duct system required by section 610 of the International Fire Code to have a Type 1 hood shall be protected with an approved automatic fire -extinguishing system installed in accordance with this code. (IFC 610.2, IFC 904.2.1 and IFC 904.11) Automatic fire -extinguishing systems shall comply with UL 300 or other equivalent standards and shall be installed in accordance with the requirements of the listing. (NFPA 96, 10.2.3) 16: Type I hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliances, by means of heat sensors or by means of other approved methods. (IMC 507.2.1.1) 17: U.L. central station supervision is required. (City Ordinance #2327) doc: IMC -4/10 M13-112 Printed: 07-22-2013 18: All new automatic fire-extinguis systems and all modifications to existing au atic fire -extinguishing systems shall have fire department review aiWproval of drawings prior to installation or nWication. 19: Portable fire extinguishers shall be provided within a 30 -foot (9144 mm) travel distance of commercial -type cooking equipment. Cooking equipment involving vegetable or animal oils and fats shall be protected by a Class K rated portable extinguisher. (IFC 904.11.5) 20: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 21: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 22: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. .1....• IMit(' A/111 M11_119 Printed. 07-22-2013 CITY OF TUKWIO*4 Community Developme,. Jepartinent Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE .LOCATION King Co Assessor's Tax No.:e29 44's OOH 7'7 Site Address:`,,e)Z13j 4 AW- L C % Suite Number: /00 Floor: Tenant Name: Ala _ ifs PROPER': Nameto W1�`�/(912 , Cv.(4Vf Address: City: State: Zip: CSO �0 n ® y Name: 4 a c ,em ,, v ,/ ir Phop 6 f);5,, of Fax: Address;/ -4' ' ��•�'' 4191 (t / - 5 , City: State: /�,,,�nrn� Zipr®ate Pho/a) 22r' 3Fax: Email: AMA& V0/1/C 0 YA-ilev, co ( New Tenant: ❑ Yes A.. No MECHANICAL CONTRACTORINFORMATION Company Name: C,0 (OctliZIACAoki _WI? Address: ` 2 c-*, jj City: a ill State: � ���, Zi� 01 Phop 6 f);5,, of Fax: Contr Reg N colve,, d j �(,� ( WL Date: (,` Tukwila Business License No.: Valuation of project (contractor's bid price): $ Describe the scope of work in detail: Or7 g-(44-iot GN/c (-710\a- 4741Xtai tNI.W zryVr1 1‹t/ce,44.0.) 0 --op ct1-0" Use: Residential: New ❑ Replacement ❑ Commercial: New ❑ Replacement Fuel Type: Electric ❑ Gas Other: H.\Applications\Forms-Applications On Line\201 I Applications\Mechanical Permit Application Revised 8-9-11.docx Revised. August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu Floor furnace Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm Evaporator cooler Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial Unit Type Qty Fire damper Diffuser Thermostat Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICA4TI Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT 1 HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND 1 AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED AGENT: Signature: Print Name: Mailing Address: r f.� .� 4_( "1 F1 \Applications\Forms-Applications On Line \2011 Applications\Mechanical Permit Application Revised 8-9-11 docx Revised: August 2011 bh Day Telephone: City Date: trO t State Zip Page 2 of 2 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-43 1-3670 Fax: 206-431-3665 Web site: http://www.Tukwila WA.gov RECEIPT Parcel No.: 0004800017 Permit Number: M13-112 Address: 13028 INTERURBAN AV S TUKW Status: APPROVED Suite No: Applied Date: 06/21/2013 Applicant: TUKWILA DELI Issue Date: Receipt No.: R13-02183 Initials: User ID: JEM 1165 Payment Amount: $254.65 Payment Date: 07/22/2013 03:19 PM Balance: $0.00 Payee: PAUL K KIM TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7985 254.65 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 254.65 Total: $254.65 rInr• P raint-r1R Printed: 07-22-2013 City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 0004800017 Permit Number: M13-112 Address: 13028 INTERURBAN AY S TUKW Status: PENDING Suite No: Applied Date: 06/21/2013 Applicant: TUKWILA DELI Issue Date: Receipt No.: R13-01937 Payment Amount: $63.66 Initials: JEM Payment Date: 06/21/2013 11:05 AM User ID: 1165 Balance: $254.65 Payee: PAUL K KIM TRANSACTION LIST: Type Method Descriptio Amount Payment Check 7965 63.66 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 63.66 Total: $63.66 Printarl• f1R.. 1-9f113 January 31, 2014 City of Tukwila Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Mark Chang 33124 41 Lane S Federal Way, WA 98001 RE: Request for Extension Denial Permits M13-112 & PG13-090 Tukwila Deli —13028 Interurban Ave S, Ste 120 Dear Mr. Chang, This letter is in response to your written request for extension to permits M13-112 and PG 13-090. The Building Official has reviewed your letter and considered your request to extend the above referenced permit. Due to the fact that no work has been completed and that the request for extension was received after the expiration date, the permits will not be extended. If it is determined that the work is to occur new permit applications, plans, and associated fees will be required. Please keep in mind that if the applications for the same scope work are submitted within one year of the expiration, the permits will be eligible for a reduction in fees. If you should have any questions, please contact our office at (206) 431-3670. Sincerely, 1\jAridi r Marshall Technician File: Permit No. M13-112 & PG13-090 W:\Permit Center\Extension Letters\Denials\Permits\2013\M13-112 Extension Denial.docx 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Jennifer Marshall From: Mark Chang <markyongc@yahoo.com> Sent: Monday, January 27, 2014 12:13 PM To: Jennifer Marshall Subject: Permit Extension / Permit # M13-112 To Whom it May Concern, RE: Permit No: M13-112 Tukwila Deli 13028 Interurban Ave S Ste 100 Please accept this email as our request for a permit extension for permit # M13-112. Due to financial issues, the project has been put on hold and will resume again the first week of February. Please feel free to contact me with any questions and/or concerns at 206-229-3357. Thank you, Mark Chang P .T i 11 fr1)L\. n -PP fir' aexi\-941A-i' SO, 1F 44+1,e- A, -.INtn(t4 Thr 14•e)c7' ` L . • PILE COPY- . Permit No. II? *11 L2lsYa vAc,t4 �tbFar��' REVE D FOR CODE :OMPLIANCE APPROVED OL 0 2 2013 City of Tukwila BUILD, ' 4G DIVISION U 4.t tt 4. mak/-td:r {A+J ni \I 01T' fostQAto.gbet&12, 2-7-40 .4061 vt4Mt.as542. RATE 214% VAIN c.14) 1•4GW,9tW ' 141-Ypsp6staw+ 14te-44 4,00€ rozEw P 191 tglt b t w yz.NA14 Ebq t (E) 4LLde :9.4166(;)inom 61iL11\16 O ¢ -, It(, 6ttA.b w f1P-hett €1 32Stiy2c 3 5425 -to FbPO4 Slur RECEIVED CITY OF TUKWILA JUN 2 1 2013 PERMIT CENTER Dr Stan client sheet project by Imam client date checked UY74„, bdoG24-' ttOOa skIfr01(21- sc-otlet.l Thermal Cethmics fa/Rielerff Fire Protection Systems Product Data and Installation Guide SBCC B oth0 NFPA 96 IMC 1. Product Description - New and Improved FastWrap+ Thermal Ceramics new and improved FireMaster FastWrap+ is a one -layer, totally foil -encapsulated, non-combustible 2000°F (1093°C) rated, low biopersistence, flexible fireproofing wrap specif- ically tested to provide a 1 or 2 hour fire rated enclosure for hori- zontal and vertical commercial kitchen grease and air ventilation ducts. The core blanket chemistry is alkaline -earth silicate wool free of binders and lubricants. FastWrap+ is classified by Omega Point Laboratories and Underwriter's Laboratories Listing and Follow-up Service Program to ensure uniform thidmess and density specifica- tions, thus providing consistency in end physical properties for required fire ratings. FastWrap+ is a proven performance alterna- tive through extensive testing to 1 or 2 hour fire -resistance rated shaft enclosures. With its excellent insulating capability of with- standing fire condition temperatures up to 2000°F (1093°C), it pro- tects combustible constructions at zero clearance throughout the entire enclosure system. When the duct penetrates fire rated walls and floors, an approved silicone firestop sealant used in combina- tion with FastWrap+ provides an alternate means of protection to rigid shafts by maintaining the integrity of the 1 or 2 hour fire rated wall and floor assembly. FireMaster FastWrap+ is resistant to mold growth in test conditions of 75-95% relative humidity (ASTM D6329). Product Features • One -layer system with 3 optional installation techniques • Low biopersistent insulation blanket • Does not contain low temperature fiberglass or mineral wool • Shaft alternative to rigid board systems • Zero clearance to combustibles protection throughout the entire enclosure system • Lightweight, flexible wrap saves labor • Passive fire proof material does not shrink, become brittle, or lose fire fighting capabilities with age • Totally foil encapsulated system protects against material degra- dation, and potential fire hazards • Product markings on foil ensure proper material identification for easy inspections • Wide variety of through -penetration systems • Resistant to mold growth 2. Applications • 1 or 2 Hour Commercial Kitchen Grease Duct Enclosure • • 1 or 2 Hour Air Ventilation Duct Enclosure Thermal Ceramics RECEIVED CITY OF TUKWILA JUN 2 1 2013 PERMIT CENTER FaStWrap+ 11/2" Commercial:; Kitchen Grease Duct Air Ventilation Duct 3. Physical Characteristics FireMaster Product Unit Size Units/ Ctn. WtJ Ctn. FastWrap+ Roll 114" x 24" x 25' (38.1 mm x 610 mm x 7.6 m) 1 37.5 lbs. (17 kg) FastWrap+ Roll 11'1° x 48" x 25' (38.1 mm 1.2mx7.6m) 1 75 lbs. (34 kg) FastWrap+ Collar Roll 114° x 6" x 25' (38.1 mm 152mmx7.6m) 4 53 lbs. (24 kg) Color White blanket with silver foil encapsulation 4. Specifications This specification guide covers the application of Thermal Ceramics FireMaster FastWrap+ and An approved silicone firestop sealant. Application Fire Resistive Rating Enclosure System Through Penetration System Grease Ducts 1 or 2 hours 1 layer, IT FastWrap+, perimeter and longitudinal overlap 3" (75 mm), GD 544 F, GD562 F, UL G-14 OPL FS 587F UL C -AJ -7098 Air Ducts 2 hours 1 layer, 11W" FastWrap+, perimeter and longitud'mal overlap 3° (75 mm), UL V-19 C -AJ -7095, UL -W -L-7121 UL -F -C-7036 5. Performance A. Thermal Ceramics FireMaster FastWrap+ Flammability (ASTM # 84/UL 723) Foil: Flame spread 5 Smoke developed 10 Blanket: Flame spread 0 Smoke developed 0 Thermal Resistance R value per ASTM C 518 4.15 per inch at 70°F (21°C) B. Fire Stop Sealants Tremco Inc. Fyre Sil sealant or Fyre-Sil S/L Sealant (for floor assemblies only) Specified Technologies Inc. Pensil 300 Rectoseal 835+ Sealant HILTI Construction Chemicals, Division of HILTI Inc. FS One Sealant M13- 1 1 2 C. Listings Agency Reference Standard/Fife No. Omega Point Laboratories, Inc. Listing # 11660-3 Underwriters Laboratory Grease Duct Enclosures (WET): R14229; Fire Resistive Ventilation Duct Assemblies (HNJL): V-19; Through - Penetration FireStop System (XHEZ): C -AJ -7095, C -AJ -7098 NFPA Complies with NFPA 96, 2001 Edition International Mechanical Code Section 506.10.3 Commercial Kitchen Grease Ducts and Exhaust Equipment. Section 507 Commercial Kitchen Hoods, 2003 Edition New York MEA 412-02-M, 413-02-M International Code Council SBCCI Legacy Report No. 9424E BOCA Legacy Report No. 22.25 City of Los Angeles RR8425 Cal fomia State Fire Marshal 2440-1361:103 2440-1361:105 6. installation A qualified contractor in accordance with manufacturer's instruc- tions and referenced standards shall install the new or original FireMaster FastWrap+ system using the installation methods as described in sections A -D. See Figures 1 - 4 complete drawing details. Materials and Equipment: FireMaster FastWrap+ blanket, 11/2" (38.1 mm) thick, 6 pcf (96 kg/m'), 24" (600 mm), or 48° (1.2 m) wide, and 25' (7.6 m) long rolls; optional 6° wide x 20' long (150 mm x 6 m) rolls ° FireMaster FastWrap+: 25' (7.6 m) standard length, 48" (1220 mm) wide blanket helps to .minimize waste ° Aluminum foil tape 0 Minimum �4" (19.0 mm) wide filament. tape (optional) 0 Carbon steel or stainless steel banding material, minimum Y2° (12.5 mm) wide, minimum 0.015° (0.38 mm) thick, with steel banding clips " Hand banding tensioner and crimping tool ° Minimum 12 gage steel insulation pins; galvanized steel speed clips, minimum 1 Y2" (38 mm) x 11/2° (38 mm) square or 11/2° dia. (38 mm), or equivalent sized cup -head pins; capacitor discharge stud gun G Access door hardware: four galvanized steel threaded rods, 14" diameter (6.35 mm) by CV to 5° long (114 to 127 mm) with Y4" (6.35 mm) wing nuts and Y4° (6.35 mm) washers; 4° (102 mm) long steel tubing to fit threaded rods G An approved silicone firestop sealant Storage: The FireMaster FastWrap+ and an approved silicone firestop sealant must be stored in a dry warehouse environment on pallets. Pallets should not be stacked. Preparatory Wont FireMaster FastWrap+ is installed with common tools, such as knives, banders and capacitor discharge guns for applying insula- tion pins. In order to install the duct fire stop system, the surfaces of all openings and penetrating items need to be clean, dry, frost free, and free of dust. Installation techniques for Thermal Ceramics FireMaster FastWrap+ (Figures 1 and 3): 0 3" (75 mm) Overlap Wrap Telescope - Each blanket overlaps one adjacent blanket, and each blanket has one edge exposed and one edge covered by the next blanket as shown in Figures 1 and 3. The visible edges of the longitudinal overlaps all point in the same direction. ° Overlap Checkerboard Pattern - Blankets with both edges exposed alternate with blankets with covered edges, as shown in Figures 1 and 3. The visible edges of the longitudinal overlaps alternate their directions and appear on every other blanket. o Butt Joint & Collar System - Adjacent blankets are butted tight- ly together and a 6" (152 mm) wide collar of FireMaster FastWrap+ is centered over the joint, overlapping each blanket by 3" (75 mm) as shown in Figures 1 and 3. 0 2 & 3 Sided Enclosure System - When space does not allow for full wrap enclosure on all four sides of the duct, the FireMaster FastWrap+ may be installed on 2 or 3 sides of the duct and mechanically attached to a concrete or CMU assembly on the unexposed side of the duct. General: To minimize waste, FireMaster material should be rolled out tautly before measuring. Cut edges of the blanket shall be taped with alu- minum foil tape to prevent exposed edges of the insulation from wicking moisture from condensation or grease from a compromised leaking duct joint into the material and causing degradation of the fire barrier. The FireMaster FastWrap+ material may be installed with either a mechanical banding system or insulation pins and clips (see Mechanical Attachment Methods below and Figures 1 and 3). When using the banding technique, caution shall be taken to ensure that the bands are not fitted too snug as which could result in cut- ting into the blanket. To prevent blanket sag on ducts with dimen- sions greater than or equal to 24" (600 mm), insulation pins, long enough to extend through the layers of blanket insulation, are weld- ed to the duct in columns spaced 12° (305 mm) apart, between 6" and 12° (152 and 305 mm) from each edge and 101/2° (267 mm) on center along the bottom horizontal and outside vertical duct runs. Insulation pins that extend beyond the blanket wrap shall be tuned down to eliminate sharp points. Support hanger systems do not need to be wrapped provided that the steel hanger rods are at least a minimum of 3/8" (9.5 mm) diameter and the steel angle is a mini- mum of 11/2" x 1 h° x '/e" (38 mm x 38 mm x 3.2 mm), or SMACNA equivalent support system (SMACNA band strap support systems do not apply). Horizontal trapeze support systems may be incorpo- rated into the wrap enclosure. A. Overlap Wrap Telescope installation FireMaster FastWrap+ commercial kitchen grease or air ventilation duct 1 or 2 hour enclosure includes a one -layer wrap construction applied directly to all surfaces of the duct (Figures 1 and 3). The FireMaster FastWrap+ blanket is wrapped one layer 11/2" (38.1 mm) or 2" (50 mm) thick around the perimeter of the duct with a length cut to provide enough excess to overlap itself not less than 3" (75 mm). Adjacent blankets are placed to overlap the previous blanket not less than 3" (75 mm). The overlap made by adjacent blankets forms the longitudinal" overlap. The overlap a blanket makes with itself is called the 'perimeter" overlap. The wrap layer may be held temporarily in place with filament tape 1Y2" (38 mm) from each blan- ket edge and in the center of the blanket until the mechanical band- ing or pinning and clip attachment method is secured. B. Checkerboard Wrap Installation FireMaster FastWrap+ is cut to completely wrap around the perime- ter of the duct with enough excess to provide an overlap of not Tess than 3° (75 mm) (Figures 1 and 3). The blankets with both edges exposed alternate with blankets with covered edges as shown in Figures 1 and 3. The visible edges of the longitudinal overlaps alter- nate their directions and appear on every other blanket. A 3" (75 mm) longitudinal overlap is installed onto the previous adjacent , wrap forming a °checkerboard° construction. The wrap layer may be held temporarily in place with filament tape 11/2" " (38 mm) from each blanket edge and in the center of the blanket until the mechan- ical banding or pinning and clip attachment method is secured. • The repair section is to be centered on the opening and impaled upon the insulation pins. All overlap§ should be tucked into the repair opening to provide a tight fitting joint. Insulation is held in place with a 11h° square or round galva- nized or stainless steel speed dip or a minimum 1° diameter cup head pin. The excess portion of the pin shall be cut off and/or turned down to eliminate sharp edges. • The joint should be sealed using aluminum foil tape. 8. Limitations • FireMaster FastWrap+ shall be installed in accordance with Thermal Ceramics - Installation Instructions • Multiple steel ducts in a single FireMaster FastWrap+ enclo- sure system are not permitted for commercial kitchen grease ducts. Multiple steel ducts in a single enclosure are permitted for air ventilation ducts • Grease Duct Sizes > 24"x48" (600 mm x 1200 mm) insula- tion is attached using steel pins • Air Ducts: when maximum duct size dimensions are greater than 84° x 21° (2100 mm x 525 mm) in cross section, rein- force the duct with steel angles sufficient to support the total weight of the duct assembly and the FireMaster FastWrap+ enclosure Thermal Ceramics F/RiefOrR Fire Protection Systems New and Improved FireMaster 1114" FastWrap+ Commercial Kitchen Grease or Air Ventilation Duct 1 or 2 Hour. Shaft Alternative Zero Clearance to Combustibles • Minimum 3/e° (9 mm) diameter all thread steel rods do not have to be insulated • Horizontal support members may be incorporated into the enclosure wrap • The integrity of FireMaster FastWrap+ system is limited to the quality of the installation Tor personal protective equipment recommendations see the ANDS. Thermal Ceramics Is a trademark of Afagan ,uclbls Company plc. RreMaster and FastWrap are trademarks ofThennal Ceramics Inc. FastWrap products are manutacfured by Thennd Ceramics Inc. RreUaster Duct Systems are distributed by authorized distributors and no longer by 3.11. Thermos and FyreSi me &adertemas of flernee Inc. Penal la a tradename of Spedged Technologies Inc. 835+ is a tradename of RecMres 1. FS One a a tradeaame 01 10177 Inc. Special Note: The original FireMaster FastWrap+ 2" technical data and installation sheet is still available elec- tronically at www.thermalceramics.com in the data sheets section. Altemate Pinning Technique Grease Ducts Only: Sizes z 24"x48" In Cross Section Pinning Technique Required. OPL Design No. GD 544 F and GD 562 F Figure 1 UL Design No. G-14 and V-19 Drawing No. FMFW1.5001-1 1 One layer FireMaster FastWrap+ 11/2" thick _ 2 Steel banding 1' wide minimum 3 3° minimum longitudinal overlap 4 3" minimum perimeter overlap 5 6" wide FastWrap+ collar (for Butt Joint option) 6 Firmly butted joint (for Butt Joint option) 7 10 or 12 gauge steel insulation pin with 11/2" x 13.4" or 11/2° diameter galvanized speed clips (foraltemate pinning) Note: The integrity of FireMaster Duct Systems is limited to the quality of the installation. 1 lir Butt Joint Option Cross Section View Overlap Wrap Option Cross Section View Checkerboard Wrap Option Cross Section View J Exhaust —/ .- Chamber 3" Air Gap4'4i. Exhaust Riser Exhaust Hanging Brackets Supply Perforated Supply Plenum - Supply Riser tTt US1EP EXHAUST HOODS FOR COMMERCIAL COOKING EOWPMENT OOIWIp10TO114.111111 710 Perforated Steel 100w Pre -Wired Lights 20" Baffle Grease Filter Stainless Steel Grease Cup NFPR MEMBER. AMERICAN HOOD SYSTEMS, INC, 177 REASER CT. P.O. BOX 1877 ELYRIA, OH 44096 ELYRIA, OH 44096 PH: 440-865-4567 FAX: 440.865.2100 TOLL FREE: 800-854-8267 www.americanhood.com sales@americanhood.com BOX CANOPY W/ PERFORATED SUPPLY PLENUM General Specifications: • Constructed of 18 gauge steel • All joints are welded liquid tight, without seams by an automatic mig welder • Hoods are built in accordance with NFPA 96, NSF specifications, and conform to U.L. 710 standards • Grease trough is made to receive grease extracted by the filters • Grease filters are 20" baffle type, they carry a U.L. listing and are constructed of a light weight aluminum steel • Each grease trough is equipped with a stainless steel cup • Note: Factory does not cut holes in hood Available In: • Deluxe: All Stainless Steel • Hybrid: Front and Sides are Stainless Steel and Top and Baek are Aluminized • Economy: All Aluminized Hood el 48241/X -2 -PSP -F - 9ft 0" Lev Exhaust -Only Wall Canopy Hood with Front Perforated Supply Plenum with Btu x1 In 3' Back Standoff -430 SS Where dosed x1 - RLTER - 16" tali x 16" wide Ind SES Steel Baffle Filler with Hames and Bottom Hanging Hookx3 Classilied - FILTER -18" tall x 20' wide Kleen-Gard Stainless Steel Baffle Filter wits Handles and Bottom Hanging Hook. x3 UL Classified - tout Light Fbdure-High Temp Assembly. Includes Clear Thermal and Shook Resistant Globe (L55 x3 Fixture), Bulbs By Others EXHAUST RISER - Field Cut 10" X 19" xl - Fi.D CUT. SHIP LOOSE - SUPPLY RISER - 10"x 20" Supply Riser with Volume Dampers x2 -112 Pint Gnome Cup new Style, Flanged Slotted x1 - INSULATION FOR BACK STANDOFF xl -BACKSPLASH 80.00" High X 108.00" Long X 1.00" Wide Insulated 430 SS x1 -BACKSPLASH WOO' High X 18.00" Long 430 SS x1 - Face Mount 1st Swtch x1 -Face Mount Extra Switches) xl Fan111 VXD85 - Exhaust Far VXD85 High Speed Direct Drive Centrifugal Upblast Exhaust Fan with speed control (single phase only). x1 disconnect switch and 15-314" who. &Must Fan handles 2025 CFM -0.850' wc ESP, Fan runs at 1259 RPM. Exhaust Mote: 0.750 HP, 1 Phase 115 V,13.0 FLA, ODP (Open Drip Proof) - Grease Cup for Iden -dam centrifugal exhaust fans, Box Dimensions 15-3M L X 5-1116 W X 3-314 H (18 GA.) xl (Includes Down Spout) - Curb CRB23X20E On Fan # 1 xt -Hinged Base for Curb. Standard Hinge attached to curb. Used on Fans wth wheels 20 Inches or smaller. 12 x1 GA Gaivanmed. -Vented Base for Curb Fan 92 VA1-G10 - Supply Fan VAI -G10 Untempered Supply Unft wth 10' Blower in Size #1 Housing Supply Fan handles 1620 CFM @ 0.350° wc ESP. Fan runs at 662 RPM. Supply Motor. 0.500 HP. 1 Phase 115 V, 8.0 FLA, ODP (Open Drip Front) Down Discharge - Air Flow Right -> Left - Steed FItered Intake for Size 91 Modular Untempered Supply Unt 21.817 Wide x 44.375' Long x 23.375 x1 trrgh. Includes 2' MV Q Kleen Metal Mesh Filters. - Gravity Back Draft Damper, 16" wide x 18' high. Standard Galvanized Construction, 1 114" Rear Flange, for xl am 1 Untempered Fan Housing (5181) -Curb CRB21X15 On Fan # 2 x1 x1 x1 12/2/2013 City of Tukwila Department of Community Development MARK CHANG 33124 41 LN S FEDERAL, WAY, WA CHICAGO, IL 98001 RE: Permit No. M13-112 TUKWILA DELI 13028 INTERURBAN AV S, STE 100 Dear Permit Holder: Jim Haggerton, Mayor Jack Pace, Director In reviewing our current records, the above noted permit has not received a final inspection by the City of Tukwila Building Division. Per the International Building Code, International Mechanical Code, Uniform Plumbing Code and/or the National Electric Code, every permit issued by the Building Division under the provisions of these codes shall expire by limitation and become null and void if the building or work authorized by such permit has not begun within 180 days from the issuance date of such permit, or if the building or work authorized by such permit is suspended or abandoned at any time after the work has begun for a period of 180 days. Your permit will expire on 1/18/2014. Based on the above, you are hereby advised to: 1) Call the City of Tukwila Inspection Request Line at 206-431-2451 to schedule for the next or final inspection. Each inspection creates a new 180 day period, provided the inspection shows progress. -or- 2) Submit a written request for permit extension to the Permit Center at least seven(7) days before it is due to expire. Address your extension request to the Building Official and state your reason(s) for the need to extend your permit. The Building Code does allow the Building Official to approve one extension of up to 180 days. If it is determined that your extension request is granted, you will be notified by mail. In the event you do not call for an inspection and/or receive an extension prior to 1/18/2014, your permit will become null and void and any further work on the project will require a new permit and associated fees. Thank you for your cooperation in this matter. Sincerely, er Marshall Technician File No: M13-112 6300 Southcenter Boulevard Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 PEIMIT COORD G PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-112 DATE: 06/21/13 PROJECT NAME: TUKWILA DELI SITE ADDRESS:' 13028 INTERURBAN AV S X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENTS: Building Division 1111 Public Works ❑ tvyApN' (19.21113 Fire Preventionoi Structural Planning Division ❑ ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete /1 Incomplete ❑ DUE DATE: 06/25/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please RouteNI)Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/23/13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) ❑ Notation: REVIEWER'S INITIALS: DATE: Permit Cenfer.Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Contractors or Tradespeople Piker Friendly Page • General/Specialty Contractor A business registered as a construction contractor with LEtI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name Phone Address Suite/Apt. City State Zip County Business Type Parent Company JD CONSTRUCTION 2064465759 15227 34Th Drive Se Mill Creek WA 98012 Snohomish Corporation JJJD INTERNATIONAL INC UBI No. 603104660 Status Active License No. JDCONC'891KU License Type Construction Contractor Effective Date 5/31/2011 Expiration Date 5/31/2015 Suspend Date Specialty 1 General Specialty 2 Unused Business Owner Information Name Role Effective Date Expiration Date KIM, JACKIE H President 05/31/2011 Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Wesco Insurance Co 46WB001899 08/03/2012 Until Cancelled $12,000.0008/06/2012 1 Western Surety Co 61072399 05/26/2011 Until Cancelled 05/26/2012 $12,000.00 05/31/2011 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 2 Security National Insurance NA103106300 08/03/2012 08/03/2013 $1,000,000.0008/06/2012 1 Nevada Capital Ins Co NCIC0005100 05/26/2011 05/26/2012 $1,000,000.0005/31/2011 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period NAC- 0&)c-( httns://fortress.wa.Qov/lni/bbip/Print.aspx 07/22/2013 REVIEWED FOR CODE COMPLIANCE APPROVED JUL 02 2013 D City o T kwila . BUILDIN , IVISION SCOPE OF WORK CUT OFF 4R,EMOVE EXISTING COUNTER AND ELECTRIC STOVE, INSTALL NEW TYP- I KITCHEN HOOD. INSTALL NEW GAS PIPE FOR. COOKING EQUIPMENT. ELECTRIC POWER FOR. EXHAUST FAN, MAKE- UP AIR FAN, HOOD LIGHTS. SEPARATE PERMIT REQUIRED FOR: Medmnicrd Electrical Plumbing Gas Piping City of Tukwila BUILDING DIVISION SCOPE OF WORK CUT Or9 4 R IVI.OVE EXISTING COUNTER; AND ,ELECTRIC STOVE, INSTALL NEW Tom- 1 KITCHEN HOOD. INSTALL NEW GAS PIPE FOR COOKING EQUIPMENT. ELECTRIC POWER FOR EXHAUST FAN, MAKE- UP AIR PAN, HOOD LIGHTS Lae CC: g r `OFC;E:"�y# tl 4CLAVI 140 - • fit from Daligor coati Io 53 k fit ;ies. 7.4 g 6.-fw 2A , .. . 4 , D tori I•i .01- . ;i'rMiS FT f: -.I ?Ir pit Pr i "Oa E Ldp:..a.F$`r�`� y�`e .FaidI mita :Nat 14 ill? 14 it 4. 4W-#30F1inti . 51LI, . t.T 3 , tri awl- E I1'T FR ebli C, R -V ! 'b tiL. Cti `a1' --.,.`+E t. D-tI'hi 0 t-114:0474arrzlEil EkErtafll £M!EfeT104,1435.Ili 4 -64s -t0: zit pi -Id KU WM 0 0-04,10 fi4ETW,X2- 4•�04 .1.9.1-51V €lf at' y`F'1gt .. -- #-a*�+^, CO2 3�4+i p" air 1'c ',� LA Mk M Lfic :ian�'. '"+ ' I' 's�d�. e:' a'S.� I%z fk�. CONTRACTOR J D CONSTRUCTION JI3CONC 891 KU 33 124 415T LN 5 FEDERAL WAY, WA 98001 253)929 - 4008 CONTACT PERSON MARK (YONG CHANG) CELL : 20+E) 229 - 3557 E --• MAIL : MARKYONGCR a@YAl10O.COM 404117 OWNER.: MR. PAUL KIM 1122 5W 334th PL t-WERAL WAY, WA 98023 20G) 755 8042 PROJECT TITLE INSTALL TYP -- OF TUWILA DELI 13028 INTERURBAN AVE, 30, SUI TUKWIIA, 'WA 98 I G8 — 0,UrLiki t:;• , C G' E 4,, b f. . IBC O - 1J Loll G srkiP of rri -I Irlu:ri tv-9 FULLY SPL • CC'U ''At` C. ''" OJPa_ - Dry 1i,l : ..... d = E 84)111.1)1k10 AIVEA 1 L. BUILD1r1Q A 01 � X11 REVISIONS No changes shall be made to the scope' of work without prior approval of Tukwila Building Division. t4OTE: Revisions will require in submittal and may include add plan review RECEIVED CITY OF TUKWILA, TilE DELI 15 CURRENTLY OPEN AND OPERATING, IT WILL CONTINUE TO STAY OPEN AND OPERATE DURINGCONSTRUCTION. 111011 vi * 0 SCOPE OF WORK. CUT OFF 46 REMOVE EYISTING COUNTER AND ELECTRIC STOVE, INSTALL NEW Tom' I KITCHEN HOOD. INSTALL NEW GAS PIPE FOR COOKING EQUIPMENT. ELECTRIC POWER FOR. EXHAUST FAN, MAKE- UP AIR FAN, HOOD LIGHTS` CONTRACTOR z J D CON5-1 RUCTION JDCONC683 1 W 33124 41 LN 5 FEDERAL WAY, WA 98001 253)929 — 4008 CONT AQT PERSON MAS (YONG CHANG) CELL • 20G) 229 — 3557 E --MAIL : MAR1V% 7NGC(rs YAHOO.COM OWNER : MR. PAUL KIM 1 122 5W 334th 1'L FEDERAL WAY, WA 98023 20G) 755 — 8042 PROJECT TIME INSTALL Tom" - OF TU CWIL.A DEC 13028 INTERURBAN' AVE, 50, SUI 100 TUKWIIA, WA 9,51G8 A NEW EQUIPMENT LIST (BTU ) 1. DEEP FRYER (90,00(0 BTU) 2. GRIDDLE ( 40,000 BTU ) 3. RANGE ( 2G,000 BTU ) 4. CHAR-- BROILER ( 50,E BTU ) EX CEILING' i I I/4" AUTO VALVE DEEP FRYER',.s. GRIDDLE --y rr, RANGE ry DIAG M - GAS PIPE . ti EXISTING FLOOR` PLAN SCALE : 1/4 = 1 "` 0" RECEIVED CITY OF TUKWILA` JUN 212013 PERMIT CENTER • • • • G _0 2" CLEAR DUCT FROM INSIDE SHAFT • ATTACti',HOODTO ••- • WALL WITH.# •1.2'.. • • 5/5 SCREW- • • ••600 # TENSILE • STRENGTH EACH. • • - •.5CREEW TOP • HOOD FALNGE• •`- .::B?TTOM ON.EActt••:• GREASE TRAY GREASE CUP 5/8" X TYP GYP BOARD GREASE DUCT TEST (2009 IMC 506.3.2.5) Prior to the use or concealment of any portion of a grease duct system, a leak test shall be preformed, Ducts shall be considered to be concealed where installed in shafts or covered by coatings or wraps that prevent the ductwork from being visually inspected on all sides. The permit holder shall be responsible to provide the necessary equipment and perform the grease duct leakage test. A light test shall be performed to determine that all welded and brazed joints are liquid tight. A light test shall be performed by passing a lamp having a power rating of not less than 100 watts through the entire section of ductwork to be tested. The lamp shall be open so as to emit light equally in all directions perpendicular the duct walls. Test shall be performed for the entire duct system, including the hood -to -duct connections. The duct work shall be permitted to be tested in sections, provided that every joint is tested. For listed factory -built grease ducts, this test shall be limited to the duct joints assembled in the field an hall include factory welds. l� 16 GA GALVANIZED. CURB TO FAN ADAPTER . 22 GA *GALVANIZED- METAL CONVER PLATE GREASE TRAY 22 GA GALVANIZED RAIN CAP VENTED CAP 1/2" SIB'L'ING 20' N-MUF CURB W/ HINGE ran 01 VXD85 - bchaust Fan VXD85 High Speed Direct Dnve Centnfugal Upblast Exhaust Fan with speed control (single phase only), disconnect switch and 15-3/4" wheel Exhaust Fan handles 2025 CFM © -0.850" we FSP, Fan runs at 1259 RPM. Exhaust Motor: 0.750 HF, I Phase 115 V, 13.0 FLA, ODP (Open Drip Roof) - Grease Cup for kitchen -duty centrifugal exhaust fans, - Box Dimensions 15-3/4 L X 5-1/1 G W X 3-3/4 H (18 GA.) (Includes Down Spout) - Curb CRB23X20E On Fan #1 - Binged Base for Curb. Standard Hinge attached to curb. Used on Fan with wheels 20 inches or smaller. 12 GA Galvanized. - Vented Base for Curb • • ' EXISTING ROOF Fan #2 NSA IOD - 5uppy Fan NSA 1 OD Direct Detre 5u ppty Unrt with 10' Blower Size # I Housing with speed control, disconnect • switch. Supply Fan handles 1G20 CFM @ 0.250" we Fan runs at 624 RPM Supply Motor 0.500 HP, ! Phase 1 15V, 6.8 ?LA, ODP (Open Dnp Prof) Down Discharge - Air Iry Right -, Left -- Sloped Foam Filtered Intake for Size #1 Standard Untempered Supply Unit. 22' Wide x 25.875" Long x 23.375" High.. Includes 2" Foam F2 lileen Metal Mesh Filters - Curb CRB23X 14 On Fan #2 • .MAKE-UP AIR -. 34 - 2 x 6 24"O .0 3/4° S/5 METAL STRAPPING - r._ WELDED' TC3.HOOD • RAMIC • 11/2° • . • 1518" SUPPER STRUCT HANGER NO LOAD 112* ALL THREAD SAFETY SUPPORTS EACH LEND OF HOOD • a d• FIRE SUPPRESSION SYSTEM 5/5 22 GA I" MINERAL WOOL 13ATTFIRE PADS 18' BEYOND HOOFS LIT BAND SIDE AND RIGHT HAND SIDE z 0 ir f.Type I Hood Special Inspections Type I hoods and ducts shall be inspected by pproved inspection agencies that satisfy the requirements as to qualifications and reliability. Final s a cinspection reports from such approved agencies of the ype I hood and duct shall be accepted by the code official after the special inspections of hood and duct have been completed. (2009 IMC 107.2.4 & IMC 506.3.2.5) .4 • • r • • 1' '• REV CO � ANCA 'CODE. APPROVED • . JUL 0 2 2011,•- • 3 1 /8" x 22 I./2 GL 1. CttY of Tukwila. BL11 ,QING DIVES ON' UT LOCATION caw ABOVE MAKE FROM SAW CADS BUILDING: DI5 ANCE •GRAM: DISTANCE FRCICATROFP3BY LINE: DISTANCE FO`s • , AND DISTANCE`• AIR 1NTA DISTANCE OF DUCT AtOVE ADJOINING GRADE AT ALLEY: iy MIN..40" MIN. 10' MIN. 10' MIN. 10' MIN. 10' MIN. 10' MIN. 10' t cAI :IC.1t+k " VIDE 1L1Arn 12 AIR NC:YT LESS THAN OF THE A135T. 2. 1 F'`AIRSYSTEM SHALL BE ELECIR1CALLY INTERLOCKED WITH THE EXHAUST SYSTEM pUCi THAT THE aAIR *MEM WILL OPERATE WHEN THE EXHAUST SYSTEM 15 IN OPERATION. • - 3. - R 5ff4t. E PROV SED BY A FAN OR MOTORIZED DAMPER or SUFFICIENT CAPACITY. NG5 5HALL NOT BE USW FORME PURFC6E OP PROVIDE1NG MA1P AIR. CFM TO THE SPACE O itiEK THAN THE HOOD. PROVIDE i1EATER CAPABLE MR SUPPLIED TO THE SPACE TO 651" F. • • WALL CANOPY HOOD W1Tli FRONT PERFORATED SUPPLY PLENUM Hood # I • 4824 Ex -2 -PSP -F-9'" Long bthaust-only Wall Canopy Hood withFront Perforated Supply Plenum with Built -€n Standoff ® 430 5S Where used • FILTER - 16°x 1 G' Klein -Gard Stainless Steel High E.Y Baffle Filter with Handles and Bottom Hanging Hook, UL Claseified • FILTER - 16"X20" Kieen-GardStainless Steel flight Eff ciericy Baffle Filter with Handles and Bottom Hanging Hook, UL Classified o Incandescent Light - o SUPPLY RISER - Vx3G" Supply Riser with Volutin Dampers o 1/2 Pint Grease Cup _New Style, Flanged Slotted • • BACKSPIASH High X Long X I' Wide insulated 430 55 • LEFT END STANDOFF 3° Wide • LEFT 5IPE5P1.A5YI 80.00" high X 48.00' Long X I' Wide Insulated 430 55 • BACKSPLA511100.00° High X 18.00" Long X 1" Wise Insulated 43055 2009 IMC 507.2.1.1 OPERATION. Type I Hood systems shall be designed and installed to automatically activate the exhaust fan whenever cooking operations occur. The activation of the exhaust fan shall occur through an interlock with the cooking appliance, by means of heat sensors or by means of other approved methods. . 508.1 MAKEUP AIR. For mechanical makeup 'air systems, the exhaust and makeup air systems shall be electrically interlocked to insure that makeup air is provided when ever the exhaust system is in operation. Makeup air intake opening locations shall compl witti Sest4.u. • d 4 0 0 EX WALL 14 x 14 GREASE DUCT 2' • E34-^ MAKE-UP AIR ' MIN ICY- OA fu • • I.. .13UCT'3MEM' I1 TI G A -CZE JNG,•WALL.OR FLCOR.SHALL ENCI.O5ED IN A DUCT ENCLOSURE FROM .'I'OIlf :O1*i P TION TO ThE =NM MR. • • • • 2. fOR CG CO UANt FUR?0S 5, IT 15 ACCEPTABLE TO- ASSUME THAT DUGS PENETRATING comcgerettOcK OR STEEL CEILINGS. WALLS OR FLOORS SHALL REQUIRE A 2 -HOUR r1 515TiVVE • ELECT L U AND FOR O Ci' EM 1T SHALL BE 1 HOUR. ' 3. D JC:T ENCWSURES SHALL 1 E•SEPARATED FROM THE DUCT BY AT trier 3 ANI? NOT MORE THAN 12'. 4. PUCT ENCLOSORE WL SEALED AROUND THE DUCrATn-te POINT OF PENETRATION AND V • X A • l ER4 iECTED OPENING. _ • S. ENCIX*RES MALL SERVE ONLY ONE KITCHE -EXh1AUST DUCT. . G. T#GHT-FITfl ; « =' (SINGS SIIAU. BE PROVIDED AT EACH CLEANOUTIMOR. ACCESS ENCLOSURE=T5i5tIAIL HAVE A FIRE-RE515TANCE.RATRiG EQUAL TO THE ENCLOSURE ADDTIO 'IN'INFO. O . ; RTYPE 1 00 0 .O LY: 1. GW5E FILTERS SHALL.I AT MIN. 450 ANGLE AND IP1a" WITH DomTRAY ' AND G MOM _ T'AI. ED EDGE PO FILTERS. DISTANCE BEAN LOWEST EDGE OF GCSE FLIERS AND COOKING SURFACE OF GRILL., AND EXPOSE FLAME SHAI.1.13E NOT LESS THAN 2 FT; USED CHARCOAL CIiARBROIL SHALL BE NOT LESS THAN 3 I/2 FT. •- 3. • TitrE111000 AND DUCT SHALL HAVE CLEARANCE FROM C 3MBUS1IBLE CONSTRUCTION OF: PROTECTED WI 1 HOUR FIRE RATED MATERIAL HOOD MIN. 3° Dt3 Tt C MIN. -18 Z"? : •DUCT. MON. 3' • • -ISM CEIUNGS CR WALLS SHAH. BE MEED 3OUDLY. 5HALL 13E MADE WITH CONTINUUM. UE ]1D�TIGHT WELD OK BRAZE MADE _._.ACE F0 THE DUCT SYSTEM. VIBRATION INSULATION CONNECTOR MAYBE CON519T5 OrNONCOMBLITSTIOLE PAC'tJNG•IN A METAL SI,VE;101NT.• FOR DISCHARGING EASE Ott1A5tJT5HAI1.ISE-F'O511ONE#,IN A BOTTOM FOSITI N ONLY A DUCT THAT•DIVE TS THE FAN DISCHARGE SHALL NOT . 2. • • Elf -rED:.. . . Hoop MIN: =i'i 4. H9 V5 5. AI.4. • ON.: - USED rgovitiOrr G.- - CENTRIPLUG liOgrZONTALI •• 3 Tat-6 D1N 1r or THE mkt • CtUTI 'CONN TO TIS FAN OUTLET ;T DUCT . SHALL BE P MEED WITt AN ADEQUATE D 1N OPENING AT THE LOWEST POINT TO !MIT • ..D * E TO A Stift' COLLECTION DEVICE. - - • # 12 5/S SCREW 600 T.S. 9' TYP - 1 1100D EQUIPMENT LIST 1 . DEEP FRYER ( 90,000 BTU) 15 1/4" 2. GRIDDIf ( 40,000 BTU) 24" 3. GAS RANGE ( 26,000 BTU) 24" 4. CHAR- BROILER ( 50,000 BTU) 24" X WALL .fig�'�'t. JAN 18 '0 r �-7•"` co r • •I i .• •--� SCALE: 3/4' = 1 '- 0" 9'-9" eq - PARCEL NO 0004500017 SCOPE OF WORK CUT OFF COVE EXISTING COUNTER AND ELECTRIC STOVE, INSTALL NEW TYP- 1 KITCHEN HOOD. INSTALL NEW GAS PIPE FOR COOKING EQUIPMENT. ELECTRIC POWER FOR EXHAUST FAN, MAKE- UP AIR FAN, 1100D LIGHTS CONTRACTOR R ' CTOR : J ID CONSTRUCTION .1DCONC'891 KU 33124 415T LN 5 FEDERAL WAY, WA 98001 253)929 - 4008 CONTACT PERSON : MARK (YONG CHANG) CELL : 206) 229 - 3557 E - MAIL : MARKYONGCCOYAIIOO.COM OWNER : MR. PAUL KIM 1 122 5W 334th PL FEDERAL WAY, WA 98023 206) 755 - 8042 PROJECT TITLE : INSTALL TYP - 1 KITCHEN 11000 OF. TUKWILA DELI 13028 INTERURBAN AVE, 50, SUITE 100 TUKWILA, WA 98I 68 REC CITY OF TUKWILA .JUN 2 1 2013 PERMIT CENTER • 2 ` 3 0 0 0 0 0 .O 0 0 0 0 o 0 �.. -. X WALL .fig�'�'t. JAN 18 '0 r �-7•"` co r • •I i .• •--� SCALE: 3/4' = 1 '- 0" 9'-9" eq - PARCEL NO 0004500017 SCOPE OF WORK CUT OFF COVE EXISTING COUNTER AND ELECTRIC STOVE, INSTALL NEW TYP- 1 KITCHEN HOOD. INSTALL NEW GAS PIPE FOR COOKING EQUIPMENT. ELECTRIC POWER FOR EXHAUST FAN, MAKE- UP AIR FAN, 1100D LIGHTS CONTRACTOR R ' CTOR : J ID CONSTRUCTION .1DCONC'891 KU 33124 415T LN 5 FEDERAL WAY, WA 98001 253)929 - 4008 CONTACT PERSON : MARK (YONG CHANG) CELL : 206) 229 - 3557 E - MAIL : MARKYONGCCOYAIIOO.COM OWNER : MR. PAUL KIM 1 122 5W 334th PL FEDERAL WAY, WA 98023 206) 755 - 8042 PROJECT TITLE : INSTALL TYP - 1 KITCHEN 11000 OF. TUKWILA DELI 13028 INTERURBAN AVE, 50, SUITE 100 TUKWILA, WA 98I 68 REC CITY OF TUKWILA .JUN 2 1 2013 PERMIT CENTER •