HomeMy WebLinkAboutPermit M13-119 - THE CONTAINER STORE - REPLACE ROOF TOP UNITSCONTAINER STORE, THE 2437 SOUTHCENTER MALL M13-119 City of/Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206.431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 2437 SOUTHCENTER MALL TUKW Project Name: CONTAINER STORE, THE Permit Number: M13-119 Issue Date: 09/17/2013 Permit Expires On: 03/16/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: SCOTT KANAGA Address: 2805 FAIRMOUNT ST, STE 300 , DALLAS TX 75201 Email: SCOTT.KANAGA@GFF.COM Contractor: Name: WHITING TURNER CONTR CO. THE Address: 300 E JOPPA RD , BALTIMORE MD 21286-3048 Contractor License No: WHITITC099LG Phone: 214 303-1500 Phone: (410) 821-1100 Expiration Date: 09/17/2015 DESCRIPTION OF WORK: INSTALL (6) NEW RTUS FOR NEW TENANT BUILD OUT. INSTALL NEW EXHAUST FANS FOR TENANT RESTROOMS AND ELECTRICAL ROOM. Value of Mechanical: 240,000.00 Type of Fire Protection: SPRINKLERS/AFA Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $2,744.56 International Mechanical Code Edition: 2009 Date: // 7(73 I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this pe Signature: Print Name: Ce Date: °I/17 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. J ..... IfAfl A/1A RAI _110 Printar1• nQ-17-7(113 • PERMIT CONDITIONS Permit No. M13-119 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 4: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 5: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 6: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 7: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 8: ***FIRE DEPARTMENT CONDITIONS*** 9: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 10: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 11: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 12: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 13: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 14: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 15: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) 16: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 17: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 18: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. doc: IMC -4/10 M13-119 Printed: 09-17-2013 i• CITY OF TUKWILA Community Development Deportment Permit Center 6300 Southcenter Blvd., Suite 100 Tukwila, WA 98188 http://www.TultwilaWA.gov Mechanical Permit No._ / v ` 1�r Project No. Date Application Accepted: Date Application Expires: C x,13 (For Office use only)' MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: 262304-9023 Site Address: 2437 Southcenter B V& Tenant Name: 771-M: 4,417XVIC iP 6775PA PROPERTY OWNER Name: WEA Southcenter Address: 2800 Southcenter City: Tukwila State: WA Zip: 98188 CONTACT PERSON — person receiving all projcct communication Name: Scott Kanaga Address: 2808 Fairmount St, Suite 300 City: Dallas State: TX Zip:75201 Ph' 214-303-1500 Fax: Email: scott.kanaga@gff.com Suite Number: 1575 Floor: 1&2 New Tenant: ® Yes ❑..No MECHANICAL CONTRACTOR INFORMATION Company Name: Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): S 479095000 240, oC9C) Describe the scope of work in detail: /IiEW R71.15 /) F6le Mae 77A4 JT �3Kt 2 —Dur. /f/E,0 awgasr FANS ,G,e TENANT" oeesrEeciMS tks0 t 7eK'/PL Aor4, Use: Residential: New ❑ Replacement El Commercial: New 0 Replacement 0 Fuel Type: Electric..... ❑ Gas ....... ® Other: 11^Applmalwnaur ms -Applications Un 1.in0201 I Apphcatiun. Mcchamuul Pcimrl Applicnuun Rcnscd 8 9-1!,dues ttavrsed: August 201 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu / Furnace >100k btu Iz. Floor fumace S Suspended/wall/floor mounted heater 2 Appliance vent Repair or addition to heat/re frig/coo l ing system Air handling unit /_ <10,000 cfm L!J Unit Type Qty Air handling unit / >10,000 cfm Iz. Evaporator cooler S Ventilation fan connected to single duct 2 Ventilation system Hood and duct Incinerator - domestic Incinerator - comm/industrial Unit Type Qty Fire damper / Diffuser Iz. Thermostat S Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction - in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review - applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated Section 105.3.2 International Building Codc (current edition). I HEREBY CERTIFY TIIAT I IIAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORJZED AGENT: Signature: Date: 613 Print Name: APV/4/65- b • \ 6 (7.---d Day Telephone: 2c.)6 ` ZI7 37 Mailing Address: 2d J77TD�7<-- 77i(-f4//(,1-.G� j�6/$x. City State Zip Ili..lpplicellonslFomu-Applicm On Lute120 11 \pplicatuns`Nlechvnieol Permit Applicubon Revised 3-0-11 ducx Res lsed August 21111 bh Page 2 [4'2 tib CCity of Tukwila 90a Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 • Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M13-119 Address: 2437 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 06/28/2013 Applicant: CONTAINER STORE, THE Issue Date: Receipt No.: R13-02613 Payment Amount: $2,195.65 Initials: WER Payment Date: 09/12/2013 01:24 PM User ID: 1655 Balance: $0.00 Payee: WHITING -TURNER CONTRACTING COMPANY TRANSACTION LIST: Type Method Descriptio Amount Payment Check 0734942 2,195.65 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 2,195.65 Total: $2,195.65 fill(" P,.rpint-nR Printerl• n9 -17-7n13 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M13-119 Address: 2437 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 06/28/2013 Applicant: CONTAINER STORE, THE Issue Date: Receipt No.: R13-02024 Payment Amount: $548.91 Initials: JEM Payment Date: 06/28/2013 10:52 AM User ID: 1165 Balance: $2,195.65 Payee: PETE FITZGIBON, BY PHONE TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 040135 ACCOUNT ITEM LIST: Description 548.91 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 548.91 Total: $548.91 Prinforl• INSPECTION NO. INSPECTION RECORD. Retain 'a. copy with permit alt3-c PERMIT NO. CITY OF TUKWILA. BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project:) (- 0r3- 4-;&Ief }C:"/ ' Type i;Inspection: r ioW s11(. 19 Ad res X:31 " 6�,mqi Date Called:. :;,Jia -c_" Special Instructions:. " Date nted: m. Requester: Phone No: ppraved per applicable codes. [Corrections required prior.to approval. COMMENTS: M‘40 ):/ — APpi U j, INSPECTION FEE REQUVRED. Prior :(onext inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO.. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)431-3670 Permit Inspection Request Line (206) 431-2451 m t- - t t 5 1. Project:stioio Type of �aspection Address: 2,1-17 SCS MAI 1 Date Called:. Special Instructions: Date Wagted: — �- y, l .- ( Lip.% p.m. Requester: Phone No:. EJApproved per applicable codes. ElCorrections required prior to approval. COMMENTS: e, A • -0 A5 S 6 zr( C) `� k a- 2 t it 3 i 't' S -CA; led z- Pie i 4-t A+; ktk zt1 d i (too '44 1-)1c60 C>oov- hues\u(e cto( C -o c -e i1/4.)Stm (lfV Date: REINSPECTION FEE' ' EQUIRED.Prior-to next inspection, fee must be aid at 6300 Southce'dter Blvd.. Suite 100. Call to schedule reinspection:.. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proj t:/' t Type of Inspection: Address: 2�t3� SC MA1� Date�Called: y�/su IA MM ,4/... 4,p /4047 Special Instructions: Date Wanted: ' — 2 S a" p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. COMMENTS: — Qp(eic4 Cz). 1-‘e-1 -Japprx/-� Dater _ i R NSPECTION FEE REUIRED.'Prior to next inspection, fee must be aid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Project Project "St Type §I.nspection: 11 O i- otc,h-:ti1. - 1 13(le )v1iJ1(-- 5,c1 Address: L -j 3-7 S C to is \ Date Called: D�.t -. L'J u! • Li ) Special Instructions: Date Wanted: l I a.nm: Requester: Phone No: QApproved per applicable codes. LJ Corrections required prior to approval. COMMENTS: F. A , O i- otc,h-:ti1. - 1 13(le )v1iJ1(-- 5,c1 .R o,.r-i - C,wv Sen -4 ,9-v j Li ) 1-,t t`-\_,.1 Su 1014 irk) A- PA ✓o./ m ; -t1 A-1 5 A L 1- 1rtrvd-1 OAAAAlt S "v./\) , / N Date: 1/ / 1— 0—i EINSPECTION FEE REQ RED. Prior to next inspection, fee must be p ' ' at 6300 Southcenter Blvd., Suite 100: Cali to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKVVILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-367 Permit Inspection Request Line (206) 431-2451 M(3 -I(1 Project:•—.-- (--,o Ara, 5 ((ol e Ty of Inspection: i o(..) 6 t4 _i. Al e Address: 73'7 M -I( Date Called: ..sem- Special instructions: (., neVi t'�TU�S Date Wanted:fJ .a mj (I —f s "'13 p.m. Requester: —Ft) N Phone o• ?/o (o - -7 S-2.3'?c? Approved per applicable codes. Corrections required prior to approval. COMMENTS: (Dk_ 1--O ' S L . pP "`%JA f Inspector: n REINSPECTION FEE REQUIRE Prior to next inspection, fee must be paid at 6300 Southcenter Blvd., uite 100. Call to schedule reinspection. INSPECTION NUMBER INSPECTION RECORD Retain a, copy with permit VIA i J r 'i PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East. Tukwila, Wa. 98188 206-575-4407 Project: Qom..,. C" c /`" 3- (--s Type of Inspection: • (Le_ .1 ------- Address: Suite #: Z u(; "') SC. blit dk- I 1 Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: Date: 24'rl !/ Sprinklers: Fire Alarm: i Hood & Duct: --"Q---c,',.. ''.i;" 4 b d*(_ 0 \H Voie kt—ei 0--,---- 0.4...,./.......4 _ . . 3 1.A.,....„.-Y-C4. S .Gf 1V eC.,/T � �? 12 sf. /" Ws.)� c - _. fr t!. r t i�' C t? d '�1L � _ A., tom., ✓,. L. ate( , Q -,,,1- -- s,+ A-1-., -Vec) - , .1, y -4-e-,— t "ST ihci--$ - .62S -'r c".., 3 b r )2 /t -t t vp r • IN: c...V` � 1.. % L. t / .2C/1 S Ra.�iC.!n.•P c--1-0 D. w1 .--._�.0 ir't C •?rte v _47, a' Ro,.. -/ pa --- �-/yam J 4. Needs Shift Inspection: Date: 24'rl !/ Sprinklers: Fire Alarm: i Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector: Date: 24'rl !/ Hrs.: /. 6 i $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 AIRIEST Co., Inc. Preliminary Test and Balance Report ry\t-- 11 ck FIRM: Airtest Co Inc PO Box 86 Issaquah, WA 98027 PHONE: 425-313-0172 FAX: 425-313-5735 CITY OF TUKD ►nrriA FEB 2 6 2014 PERMIT CENTER PROJECT: The Container Store -Southcenter Mall 633 Southcenter Mall Blvd. Tukwila, WA 98188 DATE: 2/21/2014 CONTACT: Mike Touchette NOTES: Airtest Co Inc PROJECT #: 14-2001-1 AIRTEST Co., Inc Deficiency Report PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette ID Name 1 Ares Sta'tus,; allele y I su `Action -' I aie ; ° c P ° ° elrfarined By 0006 RTU -5 Electric Room 112 Open Can not balance without controls assistance. They control the 2 modulating dampers on the supply. As well as fan speed, based on demand. Fan will only run at 50% currently. We also will need their assistance in setting minimum OSA. (Typical All RTU's) Type: Not Assigned Created 12 -Feb -14 Mike Touchette Recheck Fixed Accepted Comments / Signature 0019 EF -2 Janitor 111 Open No volume dampers found. Type: Not Assigned Created 21 -Feb -14 Mike Touchette Recheck Fixed Accepted Comments / Signature 0020 EF -1 Electric Room 112 Open Fan is @ 68% of design CFM, @ maximum rpm. Type: Not Assigned Created 21 -Feb -14 Mike Touchette Recheck Fixed Accepted Comments / Signature Airtest Co Inc AIRTEST Co. Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 nc. DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -1 (osa) AREA: Sales 100 nit Data) Unit Manufacturer Unit Model Number Unit Serial Number RTU -1 (osa) / Supply Fan Fan Type / Class Lennox LGH180H4BM2G 5613K01990 FC / 1 est Da Design External SP Actual Ext. SP Suction Actual Ext. SP Discharge Actual Total Ext. SP RTU -1 (osa) / Supply Fan Fan RPM Actual A. Tot. Inlet SP A. Tot. Discharge SP TSP Actual 1.80 in. wc -0.35 in. wc 0.81 in. wc 1.16 in. wc 816 RPM -.55 in. wc. .81 in. wc. 1.36 in. wc. ca Dal RTU -1 (osa) / Supply Fan Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 476 Volts 477 Volts 478 Volts 5.6 Amps 5.7 Amps 5.5 Amps Tested By: Mike Touchette Test Date: February 21, 2014 RTU -1 (osa) / Supply Fan Motor Manufacturer Motor HP Motor RPM Motor Frame Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor US Motors 7.5 HP 1765 RPM 213TZ 460 Volts 3 60 Hz 9.4 Amps 1.15 V RTU -1 (osa) / Supply Fan Drive Type Belt Belt Size BX64 Number of Belts 1 Motor Sheave VP60 © min Motor Sheave Bore 1 3/8 in. Fan Sheave BK104H Fan Sheave Bore 1 7/16 (H) in. Sheave Center Line 21 7/8 in. Total CFM Design Design GRD Total CFM Actual GRD Total CFM Outside Air CFM Design Return Air CFM Design 6000 CFM 6000 CFM 5925 CFM 1365 CFM 4635 CFM :sr_ RTU -1 (osa) / Filter Bank Filter Manufacturer Filter Type MERV Rating Filter Quantity Filter Size Flanders Pleated 8 6 24x24x2 Inches Airtest Co Inc AIRTEST Co., Inc. Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -1 (osa) (Cont.) AREA: Sales 100 RTU -1 (osa) Supply Outlet Summary Tested By: Mike Touchette Test Date: February 21, 2014 System / Unit .. ..44,S.w--' �. Areap Served T _ • J_ ° w A..i s _ y . ':. gi.. Outlet • • .Type , Size LxW : / D :� • d.a,., a Design- .,,, Y.:..m$ CFM Prelimr�� loety Yy .Reading,, ?4 Final -14 •mac ,, ead n 9 "w .An tea'. ° I Final).._ A. , _ .: •, < Outlet -01 Sales 100 CSD3 8 RD 145 275 150 103 Outlet -02 Sales 100 CSD3 8 RD 145 250 155 107 Outlet -03 Sales 100 CSD3 8 RD 145 50 155 107 Outlet -04 Sales 100 CSD3 8 RD 145 280 145 100 Outlet -05 Sales 100 CSD3 8 RD 145 50 150 103 Outlet -06 Sales 100 CSD3 8 RD 145 220 155 107 Outlet -07 Sales 100 CSD3 8 RD 145 250 155 107 Outlet -08 Sales 100 CSD3 8 RD 145 220 160 110 Outlet -09 Sales 100 CSD3 8 RD 145 270 140 97 Outlet -10 Sales 100 DSR1 DSR1 350 600 340 97 Outlet -11 Sales 100 DSR1 DSR1 350 640 350 100 Outlet -12 Sales 100 CSD3 8 RD 140 200 150 107 Outlet -13 Sales 100 CSD3 8 RD 140 150 150 107 Outlet -14 Sales 100 CSD3 8 RD 140 140 145 104 Outlet -15 Sales 100 CSD3 8 RD 140 200 140 100 Outlet -16 Sales 100 CSD3 8 RD 140 200 150 107 Outlet -17 Sales 100 CSD3 8 RD 140 210 150 107 Outlet -18 Sales 100 CSD3 8 RD 140 220 145 104 Outlet -19 Sales 100 CSD3 8 RD 140 190 150 107 Outlet -20 Sales 100 CSD3 8 RD 140 20 145 104 Outlet -21 Sales 100 CSD3 8 RD 140 220 140 100 Outlet -22 Sales 100 CSD3 8 RD 140 220 150 107 Outlet -23 Sales 100 CSD3 8 RD 140 230 145 104 Outlet -24 Sales 100 CSD3 8 RD 140 255 135 96 Outlet -25 Sales 100 CSD3 8 RD 140 300 130 93 Outlet -26 Sales 100 CSD3 8 RD 145 230 155 107 Outlet -27 Sales 100 CSD3 8 RD 145 230 155 107 Outlet -28 Sales 100 CSD3 8 RD 145 250 160 110 Outlet -29 Sales 100 CSD3 8 RD 145 255 160 110 Outlet -30 Sales 100 CSD3 8 RD 145 210 155 107 Outlet -31 Sales 100 CSD3 8 RD 145 0 150 103 Outlet -32 * Sales 100 CSD3 8 RD 145 110 100 69 Outlet -33 Sales 100 CSD3 8 RD 145 0 135 93 Outlet -34 Sales 100 CSD3 8 RD 145 280 140 97 Outlet -35 Sales 100 CSD3 8 RD 145 50 145 100 Outlet -36 * Sales 100 CSD3 8 RD 145 40 40 28 Outlet -37 Sales 100 CSD3 8 RD 145 140 150 103 Outlet -38 * Sales 100 CSD3 8 RD 145 30 50 34 Outlet -39 Sales 100 CSD3 8 RD 150 230 150 100 Aitest Co Inc AIRTEST Co.. Inc. Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -1 (osa) (Cont.) AREA: Sales 100 Tested By: Mike Touchette Test Date: February 21, 2014 * Notes RTU -1 (osa) / Outlet -32 RTU -1 (osa) / Outlet -36 RTU -1 (osa) / Outlet -38 21 -Feb -14 Mike Touchette Cable damper is 100% open. 21 -Feb -14 Mike Touchette Cable damper is 100% open. 21 -Feb -14 Mike Touchette Cable damper is 100% open. Airtest Co Inc AIRTEST Co.. Inc. Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -2 (osa) AREA: Sales 100 Unit Manufacturer Unit Model Number Unit Serial Number RTU -2 (osa) / Supply Fan Fan Type / Class Lennox LGH180H4BM2G 5613K01989 FC / 1 Design External SP Actual Ext. SP Suction Actual Ext. SP Discharge Actual Total Ext. SP RTU -2 (osa) / Supply Fan Fan RPM Actual A. Tot. Inlet SP A. Tot. Discharge SP TSP Actual 1.80 in. wc -0.31 in. wc 0.65 in. wc 0.96 in. wc 729 RPM -.48 in. wc. .65 in. wc. 1.13 in. wc. RTU -2 (osa) / Supply Fan Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 477 Volts 477 Volts 478 Volts 5.5 Amps 5.5 Amps 5.8 Amps Tested By: Mike Touchette Test Date: February 21, 2014 0' RTU -2 (osa) / Supply Fan Motor Manufacturer Motor HP Motor RPM Motor Frame Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor US Motors 7.5 HP 1765 RPM 213T2 460 Volts 3 60 Hz 9.4 Amps 1.15 day a RTU -2 (osa) / Supply Fan Drive Type Belt Size Number of Belts Motor Sheave Motor Sheave Bore Fan Sheave Fan Sheave Bore Sheave Center Line Belt BX63 1 BK45H 1 3/8 (H) in. BK105H 1 7/16 (H) in. 21 3/4 in. Total CFM Design Design GRD Total CFM Actual GRD Total CFM Outside Air CFM Design Return Air CFM Design 6000 CFM 6005 CFM 5805 CFM 1365 CFM 4635 CFM RTU -2 (osa) / Filter Bank Filter Manufacturer Filter Type MERV Rating Filter Quantity Filter Size Flanders Pleated 8 6 24x24x2 Inches Airtest Co Inc AIRIEST Co., Inc. Ng, Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -2 (osa) (Cont.) AREA: Sales 100 RTU -2 (osa) Supply Outlet Summary Tested By: Mike Touchette Test Date: February 21, 2014 Syst m I Unit rah l ra §ervec ,!Reading Outlet Size LxW Dein p� ii rn " l % Final Outlet -01 Sales 100 DSR1 24 x 6 450 740 420 93 Outlet -02 Sales 100 CSD3 8 RD 165 50 170 103 Outlet -03 Sales 100 CSD3 8 RD 165 270 165 100 Outlet -04 Sales 100 CSD3 8 RD 165 250 175 106 Outlet -05 Sales 100 CSD3 8 RD 165 260 170 103 Outlet -06 Sales 100 CSD3 8 RD 165 250 160 97 Outlet -07 Sales 100 CSD3 8 RD 165 290 165 100 Outlet -08 Sales 100 DSR1 24 x 6 450 1220 450 100 Outlet -09 Sales 100 CSD3 8 RD 175 225 165 94 Outlet -10 Sales 100 CSD3 8 RD 175 200 170 97 Outlet -11 Sales 100 CSD3 8 RD 175 280 170 97 Outlet -12 Sales 100 CSD3 8 RD 175 260 165 94 Outlet -13 Sales 100 CSD3 8 RD 175 240 165 94 Outlet -14 Sales 100 CSD3 8 RD 175 270 175 100 Outlet -15 Sales 100 DSR1 24 x 6 400 600 360 90 Outlet -16 Sales 100 DSR1 24 x 6 400 490 375 94 Outlet -17 Sales 100 DSR1 24 x 6 400 380 385 96 Outlet -18 Sales 100 DSR1 24 x 6 400 490 370 93 Outlet -19 Sales 100 DSR1 24 x 6 400 500 370 93 Outlet -20 Sales 100 CSD3 8 RD 180 40 180 100 Outlet -21 Sales 100 CSD3 8 RD 180 245 170 94 Outlet -22 Sales 100 CSD3 8 RD 180 230 175 97 Outlet -23 Sales 100 CSD3 8 RD 175 280 175 100 Outlet -24 Sales 100 CSD3 8 RD 175 0 180 103 Outlet -25 Sales 100 CSD3 8 RD 175 290 180 103 Ti tal :5tit15 G 83 0 � R 5 f Y ( * Notes Airiest Co Inc AIRTEST Co., Inc. Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -3 (osa) AREA: Sales 100 Unit Manufacturer Unit Model Number Unit Serial Number RTU -3 (osa) / Supply Fan Fan Type / Class Lennox LGH180H4BM2G 5613K01991 FC / 1 Actual Ext. SP Suction Actual Ext. SP Discharge Actual Total Ext. SP RTU -3 (osa) / Supply Fan Fan RPM Actual A. Tot. Inlet SP A. Tot. Discharge SP TSP Actual -0.51 in. wc 2.07 in. wc 2.58 in. wc 1064 RPM -.72 in. wc. 2.07 in. wc. 2.79 in. wc. ric� RTU -3 (osa) / Supply Fan Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 477 Volts 477 Volts 478 Volts 7.7 Amps 7.5 Amps 7.4 Amps Tested By: Mike Touchette Test Date: February 21, 2014 Airtest Co Inc RTU -3 (osa) / Supply Fan Motor Manufacturer US Motors Motor HP 7.5 HP Motor RPM 1765 RPM Motor Frame 21317 Motor Rated Volts 460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 9.4 Amps Motor Service Factor 1.15 RTU -3 (osa) / Supply Fan Drive Type Belt Belt Size BX63 Number of Belts 1 Motor Sheave VP60 @ Min. Motor Sheave Bore 1 3/8 in. Fan Sheave BK9OH Fan Sheave Bore 1 7/16 (H) in. Sheave Center Line 21 3/4 in. i Air fest Da ` " Total CFM Design 6000 CFM Total CFM Actual 6415 CFM Design GRD Total CFM 6000 CFM Actual GRD Total CFM 6025 CFM Outside Air CFM Design 1365 CFM Return Air CFM Design4635 CFM p RTU -3 (osa) / Filter Bank Filter Manufacturer Flanders Filter Type Pleated MERV Rating 8 Filter Quantity 6 Filter Size 24x24x2 Inches Airtest Co Inc AIRTEST Co. Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 nc. DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -3 (osa) (Cont.) AREA: Sales 100 RTU -3 (osa) Supply Outlet Summary Tested By: Mike Touchette Test Date: February 21, 2014 System 1 Unit b Y Aria Sewed t r a ua e 1 Outlet Size LxW Dein ,' m � tl P a 'Yo Pinal .. Outlet -01 Sales 100 DSR1 24 x 6 350 590 380 109 Outlet -02 Sales 100 DSR1 24 x 6 350 360 370 106 Outlet -03 Sales 100 DSR1 24 x 6 350 580 380 109 Outlet -04 Sales 100 DSR1 24 x 6 350 460 365 104 Outlet -05 Sales 100 DSR1 24 x 6 350 620 360 103 Outlet -06 Sales 100 DSR1 24 x 6 350 480 350 100 Outlet -07 Sales 100 DSR1 24 x 6 350 630 325 93 Outlet -08 Sales 100 DSR1 24 x 6 350 600 330 94 Outlet -09 Sales 100 CSD3 8 RD 160 125 175 109 Outlet -10 Sales 100 CSD3 8 RD 160 150 170 106 Outlet -11 Sales 100 CSD3 8 RD 160 130 175 109 Outlet -12 Sales 100 CSD3 8 RD 160 130 170 106 Outlet -13 Sales 100 CSD3 8 RD 160 50 150 94 Outlet -14 Sales 100 CSD3 8 RD 160 70 165 103 Outlet -15 Sales 100 CSD3 8 RD 160 130 170 106 Outlet -16 Sales 100 CSD3 8 RD 160 140 155 97 Outlet -17 Sales 100 CSD3 8 RD 160 120 160 100 Outlet -18 Sales 100 CSD3 8 RD 160 120 150 94 Outlet -19 Sales 100 CSD3 8 RD 160 120 165 103 Outlet -20 Sales 100 CSD3 8 RD 160 130 155 97 Outlet -21 Sales 100 CSD3 8 RD 160 110 150 94 Outlet -22 Sales 100 CSD3 8 RD 160 125 145 91 Outlet -23 Sales 100 CSD3 8 RD 160 130 150 94 Outlet -24 Sales 100 CSD3 8 RD 160 120 160 100 Outlet -25 Sales 100 CSD3 8 RD 160 100 165 103 Outlet -26 Sales 100 CSD3 8 RD 160 130 150 94 Outlet -27 Sales 100 CSD3 8 RD 160 125 145 91 Outlet -28 Sales 100 CSD3 8 RD 160 140 140 88 ki 5; a a i4 , $ 00 8 71 mss. :i * Notes Airtest Co Inc AIRTEST Co., Inc. Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -4 (osa) AREA: Entry Vestibule 114 � aI 4 ra } Ei'r. ��''t,. ai,„�i.d a��i'�. . ?;, ,�'" + ., ,. •; Unit Manufacturer Lennox Unit Model Number LGH180H4BM2G Unit Serial Number 5613K01988 RTU -4 (osa) / Supply Fan Fan Type / Class FC / 1 Test iatai u Design External SP 1.80 in. wc Actual Ext. SP Suction -0.43 in. wc Actual Ext. SP Discharge 1.16 in. wc Actual Total Ext. SP 2.59 in. wc RTU -4 (osa) 1 Supply Fan Fan RPM Actual 917 RPM A. Tot. Inlet SP -.64 in. wc. A. Tot. Discharge SP 1.16 in. wc. TSP Actual 1.80 in. wc. R{ RTU -4 (osa) / Supply Fan Motor Volts 1 478 Volts Motor Volts 2 478 Volts Motor Volts 3 480 Volts Motor Amps 1 6.1 Amps Motor Amps 2 5.9 Amps Motor Amps 3 5.9 Amps Tested By: Mike Touchette Test Date: February 13, 2014 T �iiRfi� K3j�. ra j°XPi ��GNd� m,r3 "yuwk` RTU -4 (osa) / Supply Fan Motor Manufacturer US Motors Motor HP 7.5 HP Motor RPM 1765 RPM Motor Frame 213TZ Motor Rated Volts 460 Volts Motor Phase 3 Motor Hertz 60 Hz Motor FL Amps 9.4 Amps Motor Service Factor 1.1}5} ti b " heave Data ° R{ RTU -4 (osa) / Supply Fan Drive Type Belt Belt Size BX62 Number of Belts 1 Motor Sheave VP60 @ Min. Motor Sheave Bore 1 3/8 in. Fan Sheave BK9OH Fan Sheave Bore 1 7/16 (H) in. Sheave Center Line 21 7/8 in. Total CFM Design 6000 CFM Total CFM Actual 6140 CFM Design GRD Total CFM 6000 CFM Actual GRD Total CFM 6190 CFM Outside Air CFM Design 1365 CFM Return Air CFM Design 4635 CFM i. yFiltel Data { RTU -4 (osa) / Filter Bank Filter Manufacturer Flanders Filter Type Pleated MERV Rating 8 Filter Quantity 6 Filter Size 24x24x2 Inches Airiest Co Inc AIRTEST Co.. Inc Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -4 (osa) (Cont.) AREA: Entry Vestibule 114 RTU -4 (osa) Supply Outlet Summary Tested By: Mike Touchette Test Date: February 13, 2014 SYe ► � nI I re Served �� itlet " Size LxW R > n 'G s attrr n Ina " ading# ; %Final Outlet -01 Entry Vestibule 114 CSD3 10 RD 375 425 340 91 Outlet -02 Entry Vestibule 114 CSD3 10 RD 375 420 400 107 Outlet -03 Entry Vestibule 114 CSD3 10 RD 375 460 410 109 Outlet -04 Entry Vestibule 114 CSD3 10 RD 375 430 400 107 Outlet -05 Entry Vestibule 114 CSD3 10 RD 375 430 400 107 Outlet -06 Entry Vestibule 114 CSD3 10 RD 375 440 405 108 Outlet -07 Entry Vestibule 114 CSD3 10 RD 375 430 400 107 Outlet -08 Entry Vestibule 114 CSD3 10 RD 375 430 410 109 Outlet -09 Entry Vestibule 114 CSD3 10 RD 200 250 210 105 Outlet -10 Entry Vestibule 114 CSD3 10 RD 200 240 195 98 Outlet -11 Entry Vestibule 114 CSD3 10 RD 200 250 210 105 Outlet -12 Entry Vestibule 114 CSD3 10 RD 200 210 210 100 Outlet -13 Entry Vestibule 114 CSD3 10 RD 275 350 330 98 Outlet -14 Entry Vestibule 114 CSD3 10 RD 275 320 300 96 Outlet -15 Entry Vestibule 114 CSD3 10 RD 275 320 300 109 Outlet -16 Entry Vestibule 114 CSD3 10 RD 275 400 275 100 Outlet -17 Entry Vestibule 114 CSD3 10 RD 275 370 260 95 Outlet -18 Entry Vestibule 114 CSD3 10 RD 275 380 290 105 Outlet -19 Entry Vestibule 114 CSD3 10 RD 275 400 280 102 Outlet -20 Entry Vestibule 114 CSD3 10 RD 275 375 270 98 tats : 6,1140 ' ^i1 30' 6,29!5 105 %" * Notes Airtest Co Inc AIRTEST Co., Inc. Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -5 AREA: Electric Room 112 Unit Manufacturer Unit Model Number Unit Serial Number RTU -5 / Supply Fan Fan Type / Class Lennox LCH048H4EN2G 5613K01851 FC / 1 Design External SP 0.80 in. we RTU -5 Supply Outlet Summary Tested By: Mike Touchette Test Date: February 10, 2014 RTU -5 / Supply Fan Motor Manufacturer Genteq Motor HP 3/4 (ECM) HP Motor Rated Volts 120/240 Volts Motor Phase 1 Motor Hertz 60 Hz Motor FL Amps 3.1 Amps Motor Service Factor 1.00 RTU -5 / Supply Fan Drive Type Direct Drive Design GRD Total CFM Return Air CFM Design 1600 CFM 1600 CFM RTU -5 / Filter Bank Filter Manufacturer Filter Type MERV Rating Filter Quantity Filter Size Flanders Pleated 8 4 16x20x2 Inches System Unit Area Served { k Outlet Type. Size LxW / D Des n CFM , Pr im eadir g ° Final ,Reading o Inat ..' Outlet -1 Comm 107 CSD2 12 RD 450 Outlet -2 Electric Room 112 DSR1 18 x 14 1150 1 Totals : * 5. 1 600 r * Notes RTU -5 12 -Feb -14 Mike Touchette Item 0006: Can not balance without controls assistance. They control the 2 modulating dampers on the supply. As well as fan speed, based on demand. Fan will only run at 50% currently. We also will need their assistance in setting minimum OSA. (Typical All RTU's) Airtest Co Inc AIRTEST Co. Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 nc. DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -6 (osa) AREA: Stock Room 101 Unit Manufacturer Unit Model Number Unit Serial Number RTU -6 (osa) / Supply Fan Fan Type / Class Lennox LGH072H4B2G 5613K01852 FC/1 Design External SP Actual Ext. SP Suction Actual Ext. SP Discharge Actual Total Ext. SP RTU -6 (osa) / Supply Fan A. Tot. Inlet SP A. Tot. Discharge SP TSP Actual 0.80 in. wc -0.55 in. wc 0.41 in. wc 0.96 in. wc -.84 in. wc. .41 in. wc. 1.25 in. wc. tc1 ,ic RTU -6 (osa) / Supply Fan Motor Volts 1 Motor Volts 2 Motor Volts 3 Motor Amps 1 Motor Amps 2 Motor Amps 3 476 Volts 477 Volts 477 Volts 2.8 Amps 2.8 Amps 2.9 Amps Tested By: Mike Touchette Test Date: February 21, 2014 O RTU -6 (osa) / Supply Fan US Motors 2 HP 1755 RPM 56HZ 460 Volts 3 60 Hz 2.9 Amps 1.15 Motor Manufacturer Motor HP Motor RPM Motor Frame Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor + r a a a p RTU-6 (osa) / Supply Fan Belt A50 1 VP40 © Min. 7/8 in. AK26 15/16 in. 19 in. Drive Type Belt Size Number of Belts Motor Sheave Motor Sheave Bore Fan Sheave Fan Sheave Bore Sheave Center Line Total CFM Design Design GRD Total CFM Actual GRD Total CFM Outside Air CFM Design Return Air CFM Design 2400 CFM 2400 CFM 2315 CFM 360 CFM 2040 CFM RTU -6 (osa) / Filter Bank Flanders Pleated 8 4 20x20x2 Inches Filter Manufacturer Filter Type MERV Rating Filter Quantity Filter Size Airtest Co Inc AIRTEST Co.. Inc. Roof Top Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -6 (osa) (Cont.) AREA: Stock Room 101 RTU -6 (osa) Supply Outlet Summary Tested By: Mike Touchette Test Date: February 21, 2014 * Notes Airiest Co Inc tl Ind qh i� `��h� iii�d �Jih�G d�4 ID � r �y�5� h.}yea g aI ending "t Outlet -01 Stock Room 101 DSR1 12 x 6 175 165 185 106 Outlet -02 Stock Room 101 DSR1 12 x 6 175 175 180 103 Outlet -03 Stock Room 101 DSR1 12 x 6 175 175 170 97 Outlet -04 Stock Room 101 DSR1 12 x 6 175 180 170 97 Outlet -05 Stock Room 101 DSR1 12 x 6 175 180 165 94 Outlet -06 Stock Room 101 DSR1 12 x 6 175 185 165 94 Outlet -07 Stock Room 101 DSR1 12 x 6 175 170 185 106 Outlet -08 Stock Room 101 DSR1 12 x 6 175 165 190 109 Outlet -09 Supply 103 CSD2 8 RD 75 100 70 93 Outlet -10 Break Room 102 CSD2 8 RD 200 100 180 90 Outlet -11 POS/GEN 105 CRG1 8 RD 100 95 80 80 Outlet -12 General Manager 106 CRG1 8 RD 100 100 90 90 Outlet -13 Store Manager 104 CSD2 8 RD 125 110 115 92 Outlet -14 Lockers 113 CSD2 8 RD 75 110 70 93 Outlet -15 Janitor 111 CSD2 8 RD 75 100 70 93 Outlet -16 Women 108 CSD1 8 RD 125 85 115 92 Outlet -17 Men 109 CSD1 8 RD 125 40 115 92 totals 2,400 2 ' . 2,31 * Notes Airiest Co Inc AIRTEST Co. Fan Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: EF -1 AREA: Electric Room 112 Unit Location Unit Manufacturer Model Number Serial Number Fan Type / Class Roof Greenheck G -123 -A -X 13464433 1311 BC / 1 Fan RPM Actual SP In Actual SP Out Actual External SP Actual 1625 RPM -.03 in. wc .01 in. wc .04 in. wc ectrical Motor Volts 1 Motor Amps 1 119 Volts 5.0 Amps EF -1 Exhaust Inlet Summary Tested By: Mike Touchette Test Date: February 21, 2014 Motor Manufacturer Motor HP Motor RPM Motor Frame Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor Marathon 1/2 HP 1625 RPM 48Z 115 Volts 1 60 Hz 6 Amps 1.0 Drive Type Direct Drive Total Fan CFM Des. Total Fan CFM Act. 1200 CFM 817 CFM System 4 n i y Arai SeNived .. Outlet T pe' Size LxVil; 1 D I eslgn CSMf P. hi eadin 61 Final Reading % Final Inlet -1 Electrical Room 112 20 x 10 1200 Totals. * Notes EF -1 21 -Feb -14 Mike Touchette Item 0020: Fan is @ 68% of design CFM, @ maximum rpm. Airtest Co Inc AIRTEST Co.. Inc. Fan Unit PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: EF -2 AREA: Janitor 111 Unit Location Unit Manufacturer Model Number Serial Number Fan Type / Class Roof Greenheck G -098 -A -X 13464434 1311 BI /1 EF -2 Exhaust Inlet Summary Tested By: Jacob Bowlen Test Date: February 13, 2014 Motor Manufacturer Motor HP Motor RPM Motor Frame Motor Rated Volts Motor Phase Motor Hertz Motor FL Amps Motor Service Factor Marathon 1/4 HP 1725 RPM 48Y 115 Volts 1 60 Hz 3.4 Amps 1.0 ,10 LVl Drive Type Direct Drive r Total Fan CFM Des. 500 CFM Inlet -1 Janitor 111 CEG1 8x8 100 285 Inlet -2 Men 109 CEG1 8x8 200 210 Inlet -3 Women 108 CEG1 8x8 200 175 ,0 * Notes EF -2 21 -Feb -14 Mike Touchette Item 0019: No volume dampers found. Airiest Co Inc AIRTEST Co.. Inc. Duct Traverse PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: EF -1 AREA: Electrical Room 112 Traverse Location Type of Traverse Test Instrument Used Inner Height Inner Width Duct Area # of Rows (T -B) Readings Per Row (L -R) Total Readings Inlet Duct Rectangular Pitot -Tube 16 in. 12 in. 1.333 sq. ft. 4 4 16 NOTES: Tested By: Mike Touchette Test Date: February 21, 2014 Sum of Readings Average Velocity Design Total Flow (CFM) Actual Total Flow (CFM) Static Pressure Fan RPM 9808 FPM 613 FPM 1200 CFM 817 CFM 0.03 in. wg. 1625 RPM Row 1 Row 2 Row 3 Row 4 0 Ci Duct Traverse Data Points 0 0 cs 0 12 A 4.13 Airtest Co Inc AIRTEST Co., Inc. Duct Traverse PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -3 AREA: Sales 100 Traverse Location Type of Traverse Test Instrument Used Inner Height Inner Width Duct Area # of Rows (T -B) Readings Per Row (L -R) Total Readings Discharge Duct Rectangular Pitot -Tube 24 in. 30 in. 5.000 sq. ft. 5 4 20 NOTES: Tested By: Mike Touchette Test Date: February 21, 2014 Sum of Readings Average Velocity Design Total Flow (CFM) Actual Total Flow (CFM) Fan RPM Static Pressure 25660 FPM 1283 FPM 6000 CFM 6415 CFM 1064 RPM 0.89 in. wg. Row 1 Row 2 Row 3 Row 4 Row 5 Duct Traverse Data Points O G} M O 1511 1448 1409 1349 1260 1452 1560 1491 1399 1196 1392 1483 1279 1320 822 1188 1080 1266 787 30 Airtest Co Inc AIRTEST Co Duct Traverse PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 nc. DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -4 AREA: Entry Vestibule 114 Traverse Location Type of Traverse Test Instrument Used Inner Height Inner Width Duct Area Discharge Duct Rectangular Pitot -Tube 18 in. 40 in. 5.000 sq. ft. NOTES: Tested By: Mike Touchette Test Date: February 13, 2014 in Sum of Readings Average Velocity Design Total Flow (CFM) Actual Total Flow (CFM) Static Pressure 25779 FPM 1228 FPM 6000 CFM 6140 CFM 0.55 in. wg. Duct Traverse Data Points 997 976 1543 987 902 1549 1 1346 1367 1321 1244 1101 1601 1123 1321 1043 1213 1200 1421 1 11 TT 1-7 1 1 11 11 1 40 CO A/rtest Co Inc AIRTEST Co., Inc. Duct Traverse PROJECT: The Container Store -Southcenter Mali LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -5 (T1) AREA: Electrical Room 112 Traverse Location Type of Traverse Test Instrument Used Inner Height Inner Width Duct Area # of Rows (T -B) Readings Per Row (L -R) Total Readings Discharge Duct Rectangular Pitot -Tube 14 in. 18 in. 1.750 sq. ft. 4 4 16 NOTES: Tested By: Mike Touchette Test Date: February 21, 2014 Sum of Readings Average Velocity Design Total Flow (CFM) Actual Total Flow (CFM) Static Pressure 9480 FPM 593 FPM 1600 CFM 1038 CFM 0.15 in. wg. Row 1 Row 2 Row 3 Row 4 Duct Traverse Data Points O 434 564 533 621 750 733 544 614 680 646 505 545 624 593 18 Airtest Co Inc AIRTEST Co.. Inc. Duct Traverse PROJECT: The Container Store-Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -5 (T2) AREA: Comm 107 Traverse Location Type of Traverse Test Instrument Used Duct Diameter Duct Area # of Rows (T -B) Readings Per Row (L -R) Total Readings Discharge Duct Round Pitot -Tube 12 in. 0.785 sq. ft. 2 10 20 NOTES: Tested By: Mike Touchette Test Date: February 13, 2014 Sum of Readings 0 FPM Average Velocity 0 FPM Design Total Flow (CFM) 450 CFM Actual Total Flow (CFM) 0 CFM Hole 1 Duct Traverse Data Points N 0 X 12 N r Airtest Co Inc AIRTEST Co., Inc Duct Traverse PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -6 (T1) AREA: Stock Room 101 Traverse Location Type of Traverse Test Instrument Used Inner Height Inner Width Duct Area # of Rows (T -B) Readings Per Row (L -R) Total Readings Discharge Duct Rectangular Pitot -Tube 15 in. 18 in. 1.762 sq. ft. 4 4 16 NOTES: Tested By: Mike Touchette Test Date: February 15, 2014 Sum of Readings Average Velocity Design Total Flow (CFM) Actual Total Flow (CFM) Static Pressure 24469 FPM 1529 FPM 2400 CFM 2694 CFM 0.19 in. wg. RTU -6 (T1) 11 -Feb -14 Jacob Bowlen Duct measurements 20.5 x 17.5 with 1.5 inch insulation. Row 1 Row 2 Row 3 Row 4 Duct Traverse Data Points w 0 Ci 1945 1831 1654 1503 1724 1241 1327 1479 1855 1782 1304 1026 1713 1483 1233 1379 18 Airtest Co Inc AIRTEST Co., Inc. Duct Traverse PROJECT: The Container Store -Southcenter Mall LOCATION: Tukwila, WA PROJECT #: 14-2001-1 DATE: 2/21/2014 CONTACT: Mike Touchette SYSTEM/UNIT: RTU -6 (T2) AREA: Stock Room 101 Traverse Location Type of Traverse Test Instrument Used Inner Height Inner Width Duct Area # of Rows (T -B) Readings Per Row (L -R) Total Readings Discharge Duct Rectangular Pitot -Tube 12 in. 20 in. 1.667 sq. ft. 4 4 16 NOTES: Tested By: Mike Touchette Test Date: February 15, 2014 in Sum of Readings Design Velocity Average Velocity Design Total Flow (CFM) Actual Total Flow (CFM) Static Pressure 13959 FPM 809 FPM 872 FPM 1350 CFM 1454 CFM 0.12 in. wg. RTU -6 (T2) 11 -Feb -14 Jacob Bowlen Outer measurements of 23 x 15 with 1.5 inch insulation. Row 1 Row 2 Row 3 Row 4 a ci Duct Traverse Data Points 0 20 N Airtest Co Inc 9 OPP FILE COPY Pa "w 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary MECH-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project Info Project Address Southcenter Mall Date 8/2/2013 833 Southcenter Mall Blvd. For Building Dept. Use Tukwila, WA 98188 Applicant Name: Scott Walter, Henderson Engineers, Inc. Applicant Address: 15851 North Dallas Pkwy, ste 240, Addison, TX 75001 Applicant Phone: 972-3884888 Project Description Briefly describe mechanical system type and features. Q Includes Plans Six single -zone, constant volume rooftop units condition the space. One exhaust fan serves the restrooms, and another exhaust fan pulls air from the electric room. Drawings must contain notes requireing compliance with commissioning requirements - Section 1416 Compliance Option 0 Simple System Q Complex System Q Systems Analysis (See Decision Flowchart (over) for qualifications. Use separate MECH-SUM for simple & complex Equipment Schedules The following information is required to be incorporated with the mechanical equipment schedules on the plans. For projects without plans, fill in the required information below. Cooling Equipment Schedule ' Equip. ID Equip Type Brand Name' Model No.1 Capacity2 Btu/h OSA CFM or Econo? SEER or EER IPLV3 Econmlzer Option or Exception° Heat Recovery Y/N RTU -1 CV Lennox L0H160E14a 180400 Econo 12 EER N/A Enthalpy N RTU -2 cv Lennox 101118011413 180400 Econo 12 EER N/A Enthalpy N RTU -3 CV Lennox LGH180H4B 180400 Econo 12 EER N/A Enthalpy N RTU -4 CV Lennox 141118011413 180400 Econo 12 EER N/A Enthalpy 14 RTU -5 CV Lennox LCH048H4 44900 Econo 12 EER N/A Enthalpy N RTU -6 CV Lennox LGH072H413 56800 Econo 12 EER N/A Enthalpy N Heating Equipment Schedule Equip. ID Equip Type Brand Name' Model No.1 Capacityz Btu/h OSA cfm or Econo? Input Btuh Output Btuh Efficiency° Heat Recovery Y/N RTU -1 CV Lennox LGH180H4H 384000 Econo 480000 384000 80 N RTU -2 CV Lennox LGH180H4B 384000 Econo 480000 384000 80 N RTU -3 CV Lennox LGH180114B 384000 Econo 480000 384000 80 N RTU -4 CV Lennox LGHl8OM4B 384000 Econo 480000 384000 80 N RTU -6 CV Lennox L=072114e 120000 Econo 3.50000 120000 80 N Fan Equipment Schedule IDEquip. Equip Type Brand Name Model No.1 CFM SP1 HP/BHP Flow Con ols _ _ _ EF -1 EF Greenback G -123-A 1200 0.80 0.50 V8 CQ � ���PLI�F� EF -2 EF Greenheck 0-098-A 500 0.80 0.25 VS [s��,/e�'Kje�ppj y��y■ry�� RoofAPl"RVVL.6! AUG 19 201: - n'L', /--6'1--I 'l 'If available. 2 As tested according to Table 14-1A through 14-1G. 3 If required. 4 COP HSPF, Combustion Effi 5 Flow control types: variable air volume(VAV), constant volume (CV), or variable speed (VS). 6 Exception number CORRECTION 3R NCE fab LION RECEIVED CITY OF TUKWILA AUG 0 8 2013 PERMIT CENTER G.::.. • ~r� 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Summary (back) MECH-SUM 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 System Description See Section 1421 for full description of Simple System qualifications. All Systems: 0 No humidification? IS No Reheat? If Heating/Cooling or Cooling Only: El Constant vol? • Spilt system? • <=84,000 Btuh? EI Economizer ❑<2135,000 Btuh? 0 Air cooled? El Packaged sys? • Cooling Cap <=15 Btuh/ft2? • Heating Cap. > 0 & <=10 Btuh/ft2? If Heating Only: ❑ <1000 dm? • <30% outside air? • Heating Cap. <=10 Btuh/ft2? Decision Flowchart Use this flowchart to determine if project qualifies for Simple System Option. If not, either the Complex System or Systems Analysis Options must be used. START r" h midification^,,,, or Reheat? Yes Heating Only Yes Yes eatin Cap <= 10 =tu Yes Heating/Cooling or Cooling Only Reference \ Section 1421 r Package N <=135,00' o ry Btuh $ Yes Econo included? Yes Simple System Allowed (section 1420) —.No— Co fiCap <=15 "tuff ; or Heat/Cool Eq, with "—No - ' aiCap <=10Qtuh/ft? Yes Air Cooled,"' onstant volun] Yes Total CFM Serving Single Ro t� nie No --- " Spilt System ":--,<=84.000 B(ut?„2, - -, c Yes ualifies'for Economizer., Exception ion 1 Yes Use Complex Sys ems (section 1430) Complex Systems Refer to MECH-COMP Mechanical Complex Systems for assistance In determining which Complex Systems requirements are applicable to this project. • • , 1 41 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical - Complex Systems Checklist MECH-COMP 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project Address Southceeter Mall Date 8/2/2013 The following additional information Is necessary to check a mechanical permit application for a complex mechanical system for compliance with the mechanical requirements In the Washington State Nonresidential Energy Code. Use the checklist as a reference for notes added to the mechanical drawings (see the MECH-CHK checklist for additional requirements). This information must be on the plans since this Is the official record of the permit. Having this information in separate specifications alone Is NOT an acceptable alternative. For Building Department Use Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department Notes ADDITIONAL CHECKLIST ITEMS FOR COMPLEX SYSTEMS ONLY N.A. 1431.1 Field assem. sys. Provide calculations for total onsite energy Inputioutput to equip. xes 1431.2 System Sizing Indicate equipment & system sizing complies with 1431.2 ? N.A. 1432.1 Setback & shut-off Indicate separate systems or show isolation devices on plans N.A. 1432.2.1 Air system reset Indicate automatic temperature reset & operation sequence N.A. 1432.2.2 Hydr. Sys. reset Indicate automatic temperature reset & operation sequence N.A. 1432.3.1 Hydr. Var. Flow Indicate variable flow method for all applicable systems N.A. 1432.3.X Hydronic Isolation Indicate method of isolation for all applicable systems Yee 1432.4 DDC Capabilities Indicate control capabilities including demand response setpoind adj. SPECS Yee 1432.4 DDC data mgmt Indicate metering and trending capabilities. SPECS N.A. 1432.5 Pressure Reset Indicate static pressure reset for VAV systems Yea 1433 Air Economizer Indicate economizer on equipment schedule or provide calculations to justify exemption. Demonstrate higher efficiency equipment If required.. M-2 N.A. 1433 Water Economizer Indicate water economizer and provide calculations showing compliance with 1413 if 1433 Exception 3 is utilized N.A, 1434 Separate air sys. Indicate special requirement zones and indicate systems Yea 1435 Simul. htg. & clg, Indicate method of prohibiting simultaneous heating and cooling, or state excpetlon and show supporting calculations sacs N.A. 1436 Heat recovery Indicate heat recovery of all applicable systems on plans; complete and attach heat recovery calculations Yea 1437 Elec. motor effic. MECH-MOT or Equip. Schedule with hp, rpm, efficiency =CH- MOT Yee 1438 Variable speed drives Indicate VS control or equivalent on schedules for all applicable equip. ? N.A. 1438.1 Heat Rejection Indicate heat rejection equipment types and fan types Yea 1438.2 Hot Gas Bypass Indicate cooling equipment staging and capacity modulation abilities ? N.A. 1438.3 Large Volume sys Indicate multiple system rooms & indicate ventilation control N.A: 1439.1 Kitchen Hoods Indicate source and conditioning of make-up air N.A. 1439.2 Laboratory Exhaust Indicate HR, VAV, semi -conditioned makeup, or GERM calc no is clrcted ror any question, provide exp tanatton: Decision Flowchart Start Here Use flowchart to determine how the requirements of the Complex Systems Option apply to the project. Refer to the Indicated Code sections for complete Information on the requirements. Section 1411.1 Equipment Efficiency Shall Meet Tables 14-1A through 14-1G sal Furna input > 225,000 luh or Any U Ipsco` > 500E with Design > 25 people per 000S No ietd.Assembl Equipment? Air System Serving Multiple Zones? Yes 1411.1 110 & Power Venting or Damper. If Input > 225,000 Btuh then 1412 8 Modulating Controls Required Yes Section 1411.1 0.75% Maximum Jacket Loss Yes Section 1412,8 Ventilation Controls for High -Occupancy Areas Yes Section 1431.1 Calculations of Total On-SIte Energy Input 8 Ouput Required Yes Section 1432.2.1 Supply Air Reset Controls Required 0. 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential i 1 (continued on back) 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Economizer MECH-ECO 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamlly Residential Revised August 2010 Economizer Summary Check box(es) for exceptions being claimed. List the system/equipment that qualifies for each exception. See Section 1433 for full description of Economizer requirements. 100% Outdoor Air Comparative Enthalpy Economizer Provided on RTU -1-6 ./ Full Air ❑ Ex 5: ❑ Ex 9a: • Ex 1: ❑ Ex 2: N Ex 6: MI Ex 9b: ❑ Ex 7: ❑ Ex 9c: . Ex 3: Ex 8: • Ex 4: Decision Flowchart Use this flowchart to determine If project complies with Economizer requirements. If not, the Systems Analysis Option must be used. 100% AIr conomize -Yes .,°fiedUnits„ FrdmTable 14-1A, `0,_Yes SEER t EER 15% Quer ode No ......_... Reference Section 1433 Group R Occ. ,Xz Dtion 1ict Cap < 33,000 Bibh Y03 nit not Exterior?"' ijece�i -Y03. xception 81` Unit Cap <20,000_r -.Yes— — Btuh Full Air Economizer - Complles 6tdg. Cap, We economizer <72,000 Btuh or 5%? caption I Cap <54,000 8 ,h -•-Yes-•----► it not ExEAnw, Dort Exception 2: Chilled Water Sys. filler 25% over coc 1 °Pb Yes yya r Cooled Re Bldg CO wo Ecnnb- t► -*Waterside Economize �1i0.000 etu`o s ging chilled b Sys No :Yes. No Exceplion 4. Cooling 75% Site HR or Solar s Yes r Exception T. Heat Pump Loop doOng All Critg$ Yes No t Y03— greed 14-1 A or 14-1B utpmo sc. 9a Yes— EER & IPLV ;:Yes Over No No! Exaeptitimle: F System Meeting All Criteria Does No Comply rc No RAE 127 ats 14-1N14 IIP Yes - . Yes. Water Econo F`ER & IF% 5% Ov8t Goode Yes- 4 No. Qualifies for Full AIr Economizer Exception - Complies 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Electric Motors MECH-MOT 2009 Washington State Energy Code.Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project Address southcenter wall Date 8/2/2013 Complete the following for all design A & B squirrel -cage, T -frame induction permanently wired polyphase motors of 1 hp or more having synchronous speeds of 3600, 1800 or 1200 rpm (unless one of the exceptions below applies). For Building Department Use Motor No. or Location HP Type (open/dosed) Description of Application or Use Synch. Speed Min.Nom. Full load Efficiency RTU -1 7- 1/2 SUPPLY FAN RTU -2 7- 1/2 SUPPLY FAN RTU -3 7- 1/2 SUPPLY FAN RTU -6 7- 1/2 SUPPLY FAN RTU -5 2 SUPPLY FAN RTU -6 2 SUPPLY FAN EF -1 1/2 EXHAUST FAN EF -2 1/4 EXHAUST FAN Minimum nominal f ult-Loed Efkclende r (%) As of 12/19/2010 Exceptions: 1. Motors in systems designed to use more than one speed of a multl-speed motor. 2. Motors already included in the efficiency requirements for HVAC equipment (Tables 14- 1A or 14-1 B) . 3. Motors that are an integral part (i.e. not easily removed and replaced) of specialized process equipment (Le. equipment which requires a special motor, such as an explosion - proof motor). 4. Motors integral to a listed piece of equipment for which no qualifying motor has been approved (i.e. if the only U.L. listing for the equipment Is with a less -efficient motor and there is no energy-efficient motor option). For motors claiming an exception, Ilat motor and note which exception applies. 1 Open Motors 1 Enclarmed 11bbra Synchronous Speed (RPM) 3,600 1,800 1,200 1600 1,800 1,200 MotorHP _ 1.0 77.0 85.5 82.5 77.0 35.5 82.5 1.5 84.0 86.5 66.5 34.0 86.5 87.5 2.0 85.5 86.5 87.5 85.5 86.5 8.5 6 58.5 3.0 8 5.5 89.5 33.5. 86.5 89.5 3.0 86.55 89.5 3.5 86.5 89.5 89.5 7.5 88.5 91.0 90.2 89.5 91.7 91.0 10.0 89.5 91.7 91.7 90.2 91.7 91.0 15.0 90.2 93.0 91.7 91.0 92.4 91.7 20.0 91.0 93.0 92.4 91.0 93.0 91.7 25.0 91.7 93.6 ' 93.0 91.7 93.6 93.0 30.0 91.7 94.1 93.6 91.7 93.8 93.0 40.0 92.4 94.1 94.1 92.4 94.1 94.1 50.0 93,0 94.5 94,1 93.0 94.5 94.1 60.0 93.6 95.0 94.5 93.6 95.0 94.5 75.0 93.6 95.0 94.5 93.6 95.4 95.4 100.0 93.6 95.4 95.0 94.1 95.4 95.0 125.0 94.1 95.4 95,0 95.0 95.4 95.0 150.0 94.1 95.8 95.4 95.0 95.8 95.8 200.0 95.0 95.8 95.4 95.4 962 95.3 250.0 95.0 95.8 95.4 95.3 96.2 95.3 300.0 95.4 95.8 95.4 95.8 96.2 95.8 350.0 95,4 95.8 95.4 95.8 96.2 95.3 400.0 95.6 95.6 95.8 95.8 96.2 95.8 450.0 95.8 96.2 96.2 95.8 96.2 95.8 500.0 95.3 96.2 96.2 95.8 962 95.8' -0 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist MECH-CHK Revised August 2010 2009 Washington State Energy Coda Compliance Forms for Nonresidential and Muitifamity Residential Project Address Southaanter Mall Date 8/2/2013 The followin information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington State Nonresidential Energy Code. Applicability (yes, no, na) Code Section Component Information Required Location on Plans Building Department , Notes _ HVAC REQUIREMENTS (Sections 1401-1424) 1411 Equipment Performance Yea 1411.1 Minimum efficiency Equipment schedule with type, capacity, efficiency M-2 Yes 1411.1 Combustion htg. Indicate intermittent Ignition, flue/draft damper & jacket loss SPECS N.A. 1411.1 Air-cooled chiller Provide total air and water chiller capacity N.A. 1411.2.1 Water-cooled chiller Full -load and NPLV values adjusted for any non-standard condiitons N.A. 1411.4 Pkg. elec. htg.& clg. List heat pumps on schedule N.A. 1411.5 Unenclosed Heat Indicate radiant heat system and occupancy controls 1412 HVAC Controls Yee 1412.1 Temperature zones Indicate locations on plans -1 Yes 1412.2 Deadband control Indicate 5 degree deadband minimum SPECS N.A. 1412.3 Humidity control Indicate humidistat Yea 1412.4 Setback and Shutoff Indicate thermostat with 7 day program capability & required setback SPECS Yee 1412.4.1 Dampers Indicate damper location, leakage rate, control type, & max. leakage SPECS Yea 1412.4.2 Optimum Start Indicate optimum start controls SPECS N.A. 1412.5 Heat pump control Indicate heat pump thermostant & outdoor lockout on schedule Yea 1412.6 Combustion heating Indicate modulating or staged control M-2 Yes 1412.7 Balancing Indicate balancing features on plans M-1 N.A. 1412.8 Ventilation Control Indicate demand control ventilation for high -occupancy areas N.A. 1412.9 Loading Dock & Garage Ventilation Indicate enclosed loading dock & parking garage ventilation system activation and control method. N.A. 1422 Thermostat interlock Indicate thermostat Interlock on plans N.A. 1432.2.1 _Temperature Reset Indicate temperature reset method 1413 Air / Water Economizers N.A. 1412.1 Single zone systems Indicate multiple cooling stage control capability. Yee 1413.1 Air Econo Operation Indicate 100% capability on schedule aAS.ES. N.A. 1413.1 Wtr Econo Operation Indicate 100% capacity at 45 degF db & 40 deg F wb N.A. 1413.2 WV Econo Document Indicate max. OSA condition for design clg load & equipment performance data. N.A. 1413.3 Integrated operation Indicate capability for partial cooling N.A. 1413.4 Humidification Indicate direct evap or fog atomization w/ air economizer 1414 Ducting Systems Yes 1414.1 Duct sealing Indicate duct design pressures and sealing requirements SPECS Yee 1414.1 Duct testing Indicate testing required SPECS Yes 1414.2 Duct insulation Indicate R -value of insulation on duct SPECS 1415 Piping Systems N.A. 1415.1 Piping insulation 'Indicate R -value of insulation on piping I 1416 Completion Requirement Yea 1416.3.2 System Balancing Indicate air and water system balancing requirements SPECS Yes 1416.3.3 Functional Testing Provide sequence of operations and test procedures. SPECS Yea 1416.3.4 Documentation Indicate O&M manuals, record drawings, staff training SPECS Yea 1416.3.5 Comm. Report Indicate requirements for final commissioning report SPECS Yee 1416.4 Compliance Chkllst Submit to building official upon substantial completion. SPECS Yee Mechanical Summary Form Completed and attached. Equipment schedule with types, inpuUoutput, efficiency, cfm. hp, economizer MEM' - sum 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Mechanical Permit Plans Checklist Continued MECH-CHK 2009 Washington State Energy Code Compliance Forms for Nonresidential and Multifamily Residential Revised August 2010 Project Address 9outhcenter Mall Date 8/2/2013 The followin information is necessary to check a mechanical permit application for compliance with the mechanical requirements in the Washington -State Nonresidential Energy Code. Applicability (yes, no, no) Code Section Component Information Required Location on Plans Building Department Notes SERVICE WATER HEATING AND HEATED POOLS (Sections 1440.1454) 1440 Service water htg. Yes 1441 Elec. water heater Indicate R-10 insulation under tank SPECS Yea 1442 Shut-off controls Indicate automatic shut-off of circulators or heat trace SPECS Yes 1443 Pipe Insulation Indicate R -value of insulation on piping SPECS N.A. 1444 Pump Energy Indicate method of pump energy management (Sec 1438) N.A. 1445 Heat Recovery Indicate preheat capacity as % of peak service water demand. N.A. 1452 Heat Pump COP Indicate minimum COP of 4.0 N.A. 1452 Heater Efficiency Indicate pool heater efficiency N.A. 1453 Pool heater controls Indicate switch and 65 degree control N.A. 1454 Pool covers Indicate vapor retardant cover N.A. 1454 Pools 90+ degrees Indicate R-12 pool cover N.A. 1455 Heat Recovery Indicate method and capacity of exhaust air temperature reduction 1460 Cold Storage N.A. 1463 Evaporators Indicate motor type and speed control N.A. 1464 Condensors Indicate condenser cooling type, design wb temp and control N.A. 1465 Compressors Indicate design minimum condensing temp and control. If "no" is indicated for any item in Sections 1401-1424 or 1440-1485 . provide explanation: Good Fulton & 2808 Fairmount Street Suite 300 Dallas, Texas 75201 August 2, 2013 Farrell Arc lii"tects 214.303.1500/Tel 214.303.1512/Fax www.gff.com City of Tukwila Department of Community Development 6300 Southcenter Boulevard - Suite 100 Tukwila, WA 98188 RE: R Lawrence Good FAIA LEED AP Duncan T Fulton FAIA LEED AP David Michael Farrell AIA Bryce A Weigand FAIA Karen K Quick MBA Jeffrey L Good AIA Tamara K Chambless AIA LEED AP Lawrence Cosby AIA Brian William Kuper AIA Richard L Myers AIA Jonathan P Rollins AIA Scott A Sower AIA CCCA Correction Letter #1 Mechanical Permit Application Number M13-119 The Container Store - 2437 Southcenter Mall To Dave Larson, Senior Plans Examiner, Evan L Beattie AIA LEED AP Lance Braht AIA Maria A Gomez AIA LEED AP Scott A Kanaga AIA Donald R Kubala AIA Allison E Laros MBA Brian E Moore AICP David H Swaim AIA Traci Webster IIDA Of Counsel: Joseph J Patti AIA CSI We have prepared a written response to your comments for the above referenced project. We have included four (4) signed sealed copies of the revised sets. Please let me know if you have any questions or need anything further. 1. Please complete a Washington State Energy Code Mechanical Summary form. I have included one with this review memo. Response: See attached completed Washington State Energy Code Summary. 2. The structural support of the new rooftop units has been included in the Building Permit. Please add the rooftop unit seismic anchorage details to this plan. Response: Reference detail 3 on sheet M-3 for seismic roof curb detail. 3. Provide outside air calculations per section 403.3 of the International Mechanical Code. Response: Outdoor air calculations have been added on sheet M-2. 4. Please provide the method of activation of the smoke portion of the new fire -smoke dampers. Response: All duct mounted smoke detectors for activation of fire smoke dampers are shown on sheet FP -1 5. The Interior Lighting compliance Certificate is not needed with this Mechanical Permit. It typically is accepted with the Building Permit. The form used is not the form used in this state. The Washington State Energy Code Interior Lighting Summary is the correct form. Response: Refer to attached Washington State Energy Code Interior Lighting Summary. Please let me know if you have any questions or need anything further. Thank you. Good Fulton & Farrell Architects, Inc. a=s4*---r. Scott A. Kanaga, AIA Associate Principal CORRECTION 119 P:\2013\13007 - TCS South Center - Seattle\g-jurisdictional agencies \080213 GFF Response Mechanical.doc RECEIVED CITY OF TUKWILA AUG 0 8 2013 PERMIT CENTER July 10, 2013 • City of Tukwila r Jim Haggerton, Mayor Department of Community Development Jack Pace, Director Scott Kanaga 2808 Fairmount St, Suite 300 Dallas, TX 75201 RE: Correction Letter #1 Mechanical Permit Application Number M13-119 The Container Store — 2437 Southcenter Mall Dear Mr. Kanaga, This letter is to inform you of corrections that must be addressed before your development permit can be approved. All correction requests from each department must be addressed at the same time and reflected on your drawings. I have enclosed comments from the Building Department. At this time the Fire Department has no comments. Building Department: Dave Larson at 206 431-3678 if you have questions regarding the attached comments. Please address the attached comments in an itemized format with applicable revised plans, specifications, and/or other documentation. The City requires that two (2) sets of revised plan pages, specifications and/or other documentation be resubmitted with the appropriate revision block. In order to better expedite your resubmittal, a `Revision Submittal Sheet' must accompany every resubmittal. I have enclosed one for your convenience. Corrections/revisions must be made in person and will not be accepted through the mail or by a messenger service. If you have any questions, I can be reached at (206) 431-3670. Sincerely, Bill Rambo Permit Technician File No. M13-119 6300 Southcenter Boulevard, Suite #100 • Tukwila, Washington 98188 • Phone 206-431-3670 • Fax 206-431-3665 Tukwila Building Division Dave Larson, Senior Plan Examiner Building Division Review Memo Date: July 10, 2013 Project Name: The Container Store Permit # M13-119 Plan Review: Dave Larson, Senior Plans Examiner The Building Division conducted a plan review on the subject permit application. Please address the following comments in an itemized format with revised plans, specifications and/or other applicable documentation. (GENERAL NOTE) PLAN SUBMITTALS: (Min. size 11x17 to maximum size of 24x36. Please submit all plans on the same size paper. Revised plans need to be the same size as originally submitted). (If applicable) Structural Drawings and structural calculation sheets shall be stamped and signed. 1. Please complete a Washington State Energy Code Mechanical Summary form. I have included one with this review memo. 2. The structural support of the new rooftop units has been included in the Building Permit. Please add the rooftop unit seismic anchorage details to this plan. 3. Provide outside air calculations per section 403.3 of the International Mechanical Code. 4. Please provide the method of activation of the smoke portion of the new fire -smoke dampers. 5. The Interior Lighting compliance Certificate is not needed with this Mechanical Permit. It typically is accepted with the Building Permit. The form used is not the form used in this state. The Washington State Energy Code Interior Lighting Summary is the correct form. Should there be questions concerning the above information please contact the Building Division at 206-431-3670. PERMIT COORD COPY PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-119 DATE: 08-08-13 PROJECT NAME: THE CONTAINER STORE SITE ADDRESS: 2437 SOUTHCENTER MALL Original Plan Submittal Response to Incomplete Letter # X Response to Correction Letter # 1 Revision # After Permit Issued. DEPARTMENTS: Q_�'L9 1, CT Building uivision U Public Works n Fire Prevention Structural n Planning Division n Permit Coordinator n DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete DUE DATE: 08-13-13 Not Applicable Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping ❑ PW 0 Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required nNo further Review Required REVIEWER'S INITIALS: DATE: n APPROVALS OR CORRECTIONS: Approved Approved with Conditions DUE DATE: 09-10-13 Not Approved (attach comments) n Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: Documents/routing slip.doc 2-28-02 PERMIT COORD COPY 411k PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-119 DATE: 06/28/13 PROJECT NAME: THE CONTAINER STORE SITE ADDRESS: 2437 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # after Permit Issued DEPARTMENT v —61 0-13 Building Division Public Works ❑ Av'G cirAit3 Fire Prevention Structural Planning Division ❑ Permit Coordinator ❑ DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Incomplete ❑ DUE DATE: 07/02/13 Not Applicable ❑ Comments: Permit Center Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg 0 Fire 0 Ping 0 PW 0 Staff Initials: TUESITHURS ROUTING: Please Route Structural Review Required ❑ No further Review Required ❑ REVIEWER'S INITIALS: DATE: APPROVALS OR CORRECTIONS: DUE DATE: 07/30/13 Approved ❑ Approved with Conditions ❑ Not Approved (attach comments) .e' Notation: REVIEWER'S INITIALS: DATE: Permit Center Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg Fire 0 Ping 0 PW 0 Staff Initials: WVV City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.ci.tukwila.wa.us Revision submittals must be submitted in person at the Permit Center. Revisions will not be accepted through the mail, fax, etc. Date: e 2. Plan Check/Permit Number: M1 3 -1 19 ❑ Response to Incomplete Letter # ® Response to Correction Letter # 1 ❑ Revision # after Permit is Issued ❑ Revision requested by a City Building Inspector or Plans Examiner Project Name: The Container Store Project Address: 2437 Southcenter Mall Contact Person: (77- Phone Number: RECEIVED CRY OF TUKWILA AUG 08 2013 Summary of Revision: 16 PERMIT CENTER I SlyAr 1 /IC4r .r i�_�� 4 S✓ t+ _.' .46Z—die flair= iv itkVi}i,twos7y7�" �.trl,vrc� Sheet Number(s): "1 t"4����II - /f lv% Zi /13 40112,6c,oxi, 44€3, ,,W i eet "Cloud" or highlight all areas of revision including date of revision H%, 5is 6? Received at the City of Tukwila Permit Center by: E --Entered in Permits Plus on \applications\forms-applications on line\revision submittal Created: 8-13-2004 Revised: Contractors or Tradespeople Peer Friendly Page General/Specialty Contractor A business registered as a construction contractor with LEI to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name WHITING TURNER CONTR CO, THE UBI No. 600594886 Phone 4108211100 Status Active Address 300 E Joppa Rd License No. WHITITC099LG Suite/Apt. License Type Construction Contractor City Baltimore Effective Date 6/7/1991 State MD Expiration Date 9/17/2015 Zip 212863048 Suspend Date County Out Of State Specialty 1 General Business Type Corporation Specialty 2 Unused Parent Company Other Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status WHITITC1456TWHITINGTURNER CNTRNG CO, THE Construction Contractor General Unused 1/30/1986 12/31/1986 Archived Business Owner Information Name Role Effective Date Expiration Date C T CORPORATION SYSTEM Agent 01/01/1980 Bond Amount HACKERMAN, WILLARD President 06/07/1991 9057791 IRISH, CHARLES A Vice President 06/07/1991 Bond Information Page 1 of 2 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 4 Fidelity Et Deposit Ins Co of Maryland 9057791 06/03/2011 Until Cancelled $12,000.0009/17/2013 09/17/2013 3 TRAVELERS CAS & STY CO OF AMER 400KM9671 06/03/2006 Until Cancelled 08/23/2011 512,000.00 10/05/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 19 Travelers Indemnity Company Th VTC2JC057881320ATIL13 08/01/2013 08/01/2014 52,000,000.00 09/17/2013 18 ZURICH AMERICAN INS CO GL0386588107 08/01/2010 08/01/2011 $2,000,000.00 07/20/2010 17 ZURICH AMERICAN INS CO GL0386588106 08/01/2008 08/01/2010 $2,000,000.0007/31/2009 16 ZURICH AMERICAN INS CO GL03865888104 08/01/2008 08/01/2009 $2,000,000.0007/23/2008 15 AMERICAN STATES INS CO 01CH55062910 08/01/2007 08/01/2008 $500,000.0007/16/2007 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period httos://fortress.wa.Qov/lni/bbip/Print.aspx 09/17/2013 KENNETH L. BIESMA x 8"0 CSD3 140 8"0 8"0 CSD3 140 SD3 140 8x12 14x121 8"0 CSD3 140 8"0 CSD3 140 8x12 8"0 CSD3 140 8"0 CSD3 140 14x12 8"0 SD3 140 8"0 SD3 140 8"0 CSD3 140 24x6 - -DSR1 350 ACCESS PANEL -2 24x6 DSR1 350 350 8"0 CSD3 RTU -1 140 8"0 CSD3 140 x 8"0 CSD3 ;14--i 145 8"0 CSD3 145 12x12 24x6 DSR1 350 ACCES PANEL -1 HS IE 8"0 145 8"0 L C1-453 8"0 -CSD3 145 8"0 8"0 CSD3 CD3 -1 8"0 SD -3 12x14 8"0 CSD3 .e 8"0 CD3 .a S RTU -3 8"0 C1D3 x N 14x10 r CSD3 CSD.3__ :SD3 145 145 8"9) 145 8"0 145 145 18x16 81,0 CSD3 145 co 8"0 C1 83 8"0 CD)� � 8"00 ({-TS5D 3 12x12 8"0 1453 8"0 CSD3 160 8"0 CSD3 1-60 8"0 CSD3 160 I 8"0 CSD3 12x12 8"0 8"0 CSD3 145 8'0 CSD3 145 8"0 CSD3 145 ACCESS PANEL -4 24x6 DSR1 400 x6 DSR1 400 24x6 DSR1 400 24x6 DSR1 400 24x 6 DSR1 400 RTU -2 2" RETURN OPENING. REFER TO ARCHITECT DRAWINGS FOR FURTHER INFORMATION. 20x16 110 SD 3 5_ 1 ' SDIL 3251 I>� S!D4 3 5- "0 SD$ 3'5- ACCESS PANEL -6 ■ --II ill 8"0 CSD3 ' 1-4-5 8"0 CSD3 8"0 CSD3 160 160 8"0 CSD3 8"0 CSD3 1150, 8"0 8"0 CSD3 150 8"0 Csn,3 8"0 CSD3 1-60= 12x12 8"0 CS D3 1 B I 8"0 1�5 1 12x16 . 8"0 8"0 CSD3 1175 26x16 CSD38 175 I °ACCESS PANEL -8 2" RETURN OPENING. REFER TO ARCHITECT DRAWINGS FOR FURTHER INFORMATION. CSD3' 160 1 8"0 CSD3 160 24x6 DSR1 350 24x6 DSR1 350 24x6 DSR1 350 24x6 DSR1 350 24x6 DSR1 350 24x6 DSR1 350 24x6 DSR1 350 x x N ACCESS PANEL -3 28x16 80 CSD3 160 8"0 8"0 CSD3 160 8"0 8"0 CSD3 CSD3 CSD3 165 165 165 16x16 x 0 co x 0 ACCESS 50x34 PANEL -7 84;0 CSD3 165 C CSD3 165 8"0 CSD3 165 2R PURN OPENI DRAWINGS FOR FU HER INFORMATION. 50x34 Or �` 4x6 0 8"0 -i-- SR1 450 c Q RTU ©© 8"¢ -�'- ---CSD3 � CSD 180 j s "0 G- D- IP a' RTU 18� 8"0 =SSD3 co tD 1 8"0 G ! 8"0 CSD3 1175 26x16 CSD38 175 I °ACCESS PANEL -8 2" RETURN OPENING. REFER TO ARCHITECT DRAWINGS FOR FURTHER INFORMATION. CSD3' 160 1 8"0 CSD3 160 24x6 DSR1 350 24x6 DSR1 350 24x6 DSR1 350 24x6 DSR1 350 24x6 DSR1 350 24x6 DSR1 350 24x6 DSR1 350 x x N ACCESS PANEL -3 28x16 80 CSD3 160 8"0 8"0 CSD3 160 8"0 8"0 CSD3 CSD3 CSD3 165 165 165 16x16 x 0 co x 0 ACCESS 50x34 PANEL -7 84;0 CSD3 165 C CSD3 165 8"0 CSD3 165 2R PURN OPENI DRAWINGS FOR FU HER INFORMATION. 50x34 Or �` 4x6 0 24x6 DSR1 450 - -i-- SR1 450 c Q RTU ©© 50x34 IP _ - 1 7 40 aft - . h -i 0"91 SD 325' 001 ds 5 (TYP) RTU -4 HS S 1 CSD3 325 OWP CRG2 \10"0 10" CSD3 CSD 375 37 8"0 CSD2 75 8x8 CEG1 200 MITA ei 109 MEN 4 8x8 CEG 20 0- 3 ri,. 1 • 8' _ 12x24 CSD2 o CRG1 75 r IN 110 VESTIBULE 8"0 CSD1 125 �I I =I 8"0 SD1 a 125 108 WOMEN B 11f„� TSUPPLY x24 RG1 2x24 CRG1 CSD2 125 EAK ROOhi14 1 „, x - • 18 It x N x 0 M \-ACCESS PANEL -5 • ...................... . .............................. ................................. .................................. ADJACENT ............................. ...... ........•. ....... • .................................... 12x6 DSR1 175 i 20x10 20x14 56x18 Ur4 8"0 200 24x24 CRG1 RTU - 16x12 30x24 RTU WO ©0 120 412 24x16 � 26 14 ��lt 28x14 I11 t14 Ioi 1IMIIIIIIIIIIII 0` 2 IV LL "li . 56x18 I Pi MOM WRG1 8"0 1p 0 /CSD3 / 375 CSD3 375 CSD3 375 100 0 101 STOCK ROOM 12x6 DSR1 Ai175 12x6 DSR1 175 12x6 12x6 DSR1 175 oo 12x6 175 MALL STORAGE io411m mam 12x6 175 04 STORE MGR. 106 GENERAL MANAGER CSD2 100 105 ROOF BELOW SECOND FLOOR HVAC PLAN CSD2 100 MECHANICAL KEY NOTES: • COVER OPENING IN RETURN/EXHAUST AIR DUCT WITH 1/2" HARDWARE CLOTH AT OPENING SIZE INDICATED ON DRAWING. • NEW RTU MOUNTED ON NEW ROOF CURB. COORDINATE EXACT LOCATION WITH ARCHITECTURAL DRAWINGS. • SEE P -1R SHEET FOR NATURAL GAS PIPING DETAILS. • SEE P -1R SHEET FOR CONDENSATE PIPING DETAILS. • BAS CONTRACTOR TO FURNISH AND INSTALL CO2 SENSOR IN RETURN AIR PLENUM. COORDINATE INSTALLATION WITH MECHANICAL CONTRACTOR. • ACCESS PANEL TO BE 24" X 24" PERFORATED RETURN AIR GRILLE - WHITE - WITH 30# BLACK BUILDING FELT INSTALLED ON PLENUM SIDE - TYPICAL. • INTERNALLY LINED DUCT IN EXPOSED AREAS SUCH AS STOCK ROOM - NO EXCEPTIONS. DUCT SHALL BE PAINT GRIP GALVANIZED FINISH - PAINTED PER ARCHITECTURAL DRAWINGS. • RTU -5 PRIMARY TEMPERATURE AND HUMIDITY SENSORS. 0 TEMPERATURE SENSOR INTERLOCKED WITH MOTORIZED DAMPER. MOTORIZED DAMPER SHALL OPEN/CLOSE TO MAINTAIN SPACE SETPOINT TEMPERATURE. • RTU -6 PRIMARY (MASTER) TEMPERATURE AND HUMIDITY SENSORS. • RTU -6 SECONDARY (SLAVE) TEMPERATURE AND HUMIDITY SENSORS. SEPARATE PERMIT REQUIRED FOR: Meohanical Iectrical as Piping City of Tukwila DIVISION FE OPY Permit No. 1 REVISIONS No changes shall be made to the scope of work without prior approval of , • Tukwila Building Division. NOTE: Revisions will require a new plan submittal and may include additional plan review fees. j Plan review approval is subjed to errors aixl omissions. 45:7:7,vai of construction dwurnents does not authorize thE v;t-Aation of any adopted axle or ordinance. Receipt BY aty Of Tukwila BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED AUG 1 9 2013 City of Tukwila BUILDING DIVISION GENERAL NEW NOTES: 1. PRIOR TO SUBMITTING BID, VISIT THE JOB SITE AND BECOME FULLY ACQUAINTED WITH THE EXISTING CONDITIONS OF THE PROJECT. REVIEW THE GENERAL NOTES, SPECIFICATIONS AND OTHER DRAWINGS FOR ADDITIONAL REQUIREMENTS WHICH MAY NOT BE SPECIFICALLY CALLED OUT IN THIS PORTION OF THE CONSTRUCTION DOCUMENTS. NOTIFY ARCHITECT, ENGINEER AND/OR OWNER OF CONFLICTS OR DISCREPANCIES PRIOR TO SUBMISSION OF BID. 2. EXISTING CONDITIONS WERE TAKEN FROM ORIGINAL DRAWINGS AND SITE VISITS AND MAY NOT REFLECT EXACT "AS -BUILT" CONDITIONS. FIELD VERIFY EXISTING CONDITIONS PRIOR TO SUBMITTING FINAL BIDS. COORDINATE NEW WORK AND DEMOLITION WITH OTHER DISCIPLINES AND EXISTING CONDITIONS PRIOR TO CONSTRUCTION. 3. EXISTING PACKAGED ROOFTOP UNITS AND ASSOCIATED ROOF CURBS SHALL BE REMOVED. 4. EXISTING ROOF MOUNTED EXHAUST FANS AND ASSOCIATED ROOF CURBS SHALL BE REMOVED. 5. AVOID DAMAGING EXISTING SURFACES AND EQUIPMENT TO REMAIN FOR NEW INSTALLATION. REPAIR DAMAGE CAUSED DURING WORK AT NO EXTRA COST TO THE OWNER. 6. SEAL PENETRATIONS THROUGH ROOF WHERE MECHANICAL COMPONENTS ARE REMOVED AND WHERE THE EXISTING PENETRATION IS NOT USED FOR THE NEW INSTALLATION. REPAIR DAMAGED SURFACES TO MATCH ADJACENT AREAS OR AS INDICATED ON THE ARCHITECTURAL DRAWINGS. 7. REMOVE ALL EXISTING DUCTWORK LOCATED AT THE BUILDING INTERIOR. REMOVE HANGERS AND SUPPORTS WHERE DUCTWORK IS REMOVED AND THE EXISTING HANGERS AND SUPPORTS ARE NOT USED FOR THE NEW INSTALLATION. 8. COORDINATE THE INSTALLATION OF THE MECHANICAL SYSTEMS WITH OTHER TRADES TO ENSURE A NEAT AND ORDERLY INSTALLATION. COORDINATE INSTALLATION OF DUCTWORK AND PIPING TO AVOID CONFLICTS WITH ELECTRICAL PANELS, LIGHTING FIXTURES, ETC. 9. ALL MECHANICAL EQUIPMENT SHOWN ON THE MECHANICAL PLANS SHALL BE PROVIDED BY THE MECHANICAL CONTRACTOR UNLESS OTHERWISE NOTED. 10. NEW MECHANICAL EQUIPMENT, DUCTWORK AND PIPING ARE SHOWN AT APPROXIMATE LOCATIONS. FIELD MEASURE FINAL DUCTWORK AND PIPING LOCATIONS PRIOR TO FABRICATION AND MAKE ADJUSTMENTS AS REQUIRED TO FIT THE DUCTWORK AND PIPING WITHIN THE AVAILABLE SPACE. VERIFY THAT FINAL EQUIPMENT LOCATIONS MEET MANUFACTURER'S RECOMMENDATIONS REGARDING SERVICE CLEARANCE AND PROPER AIRFLOW CLEARANCE AROUND EQUIPMENT. 11. REFER TO ARCHITECTURAL DRAWINGS FOR RELATED CONSTRUCTION DETAILS AS APPLICABLE TO THE HVAC SYSTEM. VERIFY CHASES AND PENETRATIONS SHOWN ON ARCHITECTURAL DRAWINGS THAT ARE INTENDED FOR DUCTWORK AND PIPING MEET REQUIREMENTS. 12. COORDINATE LOCATION OF ROOF MOUNTED HVAC EQUIPMENT AND ROOF PENETRATIONS WITH THE ARCHITECTURAL DRAWINGS. 13. INSTALL DUCTWORK AND PIPING PARALLEL TO BUILDING COLUMN LINES UNLESS OTHERWISE SHOWN OR NOTED. 14. OVERHEAD HANGERS AND SUPPORTS FOR EQUIPMENT AND DUCTWORK SHALL BE FASTENED TO BUILDING JOISTS OR BEAMS. DO NOT ATTACH HANGERS AND SUPPORTS TO THE ROOF. 15. COORDINATE LOCATION OF EQUIPMENT SUPPORTS WITH LOCATION OF EQUIPMENT ACCESS PANELS/DOORS TO ENABLE SERVICE OF EQUIPMENT AND/OR FILTER REPLACEMENT. CONFIRM LOCATION OF ACCESS PANELS WITH ARCHITECT PRIOR TO INSTALLATION. 16. SEAL PENETRATIONS THROUGH THE BUILDING COMPONENTS IN ACCORDANCE WITH THE CONTRACT SPECIFICATIONS. FIREPROOF PENETRATIONS THROUGH FIRE RATED COMPONENTS IN ACCORDANCE WITH U.L. REQUIREMENTS. 17. COORDINATE THE EXACT MOUNTING SIZE AND FRAME TYPE OF DIFFUSERS, REGISTERS AND GRILLES WITH THE SUPPLIER TO MEET THE CEILING, WALL AND DUCT INSTALLATION REQUIREMENTS. 18. ADJUST LOCATION OF CEILING DIFFUSERS, REGISTERS AND GRILLES AS REQUIRED TO ACCOMMODATE FINAL CEILING GRID AND LIGHTING LOCATIONS. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR DIMENSIONED LOCATIONS OF DIFFUSERS. 19. COORDINATE THE LOCATION AND ELEVATION OF WALL -MOUNTED DEVICES WITH PRESENTATION BOARDS, DISPLAY CABINETS, SHELVES OR OTHER COMPONENTS SHOWN ON THE ARCHITECTURAL DRAWINGS THAT ARE TO BE INSTALLED UNDER OTHER DIVISIONS. CONTRACTOR WILL NOT BE REIMBURSED FOR RELOCATION OF WALL - MOUNTED DEVICES CAUSED BY A LACK OF COORDINATION. 20. PROVIDE A MANUAL BALANCING DAMPER IN EACH BRANCH DUCT TAKEOFF FROM MAIN SUPPLY, RETURN, AND EXHAUST AIR DUCTS. 21. PROVIDE A PREFABRICATED 45 DEGREE, HIGH EFFICIENCY, RECTANGULAR/ROUND BRANCH DUCT TAKEOFF FITTING WITH MANUAL BALANCING DAMPER AND LOCKING QUADRANT FOR BRANCH DUCT CONNECTIONS AND TAKE -OFFS TO INDIVIDUAL DIFFUSERS, REGISTERS AND GRILLES. 22. BRANCH DUCTWORK TO AIR OUTLETS SHALL BE SAME SIZE AS OUTLET NECK SIZE UNLESS OTHERWISE NOTED. 23. FURNISH AND INSTALL INTERNAL DUCT LINER OR EXTERNAL BLANKET WRAP INSULATION ON RECTANGULAR SUPPLY AND RETURN AIR TRUNK DUCTS PER SPECIFICATIONS. INTERNAL DUCT LINER SHALL BE UTILIZED ON EXPOSED DUCTWORK. EXTERNAL BLANKET WRAP SHALL BE UTILIZED ON CONCEALED DUCTWORK. DUCT SIZES ON MECHANICAL PLANS INDICATE CLEAR INSIDE AIRFLOW DIMENSIONS, INCREASE SHEET METAL SIZES ACCORDINGLY. 24. PROVIDE THERMAFLEX TYPE G -KM, FLEXMASTER TYPE 8, OR APPROVED EQUAL FLEXIBLE DUCTWORK. FLEXIBLE DUCTWORK SHALL BE LISTED UNDER UL 181 AS CLASS 1 AIR DUCT AND BE PROVIDED WITH R8 FIBERGLASS INSULATION. FLEXIBLE DUCTWORK SHALL NOT EXCEED 5'-0" IN LENGTH AND SHALL BE INSTALLED AND SUPPORTED TO AVOID SHARP BENDS AND SAGGING. 25. PROVIDE A NEW SET OF AIR FILTERS IN UNITS PRIOR TO TESTING, ADJUSTING AND BALANCING, AND BEFORE TURNING SYSTEM(S) OVER TO OWNER. 26. INDOOR AIR QUALITY MEASURES: PROTECT INSIDE OF (INSTALLED AND DELIVERED) DUCTWORK AND HVAC UNITS FROM EXPOSURE TO DUST, DIRT, PAINT AND MOISTURE. REPLACE INSULATION THAT HAS BECOME WET AT ANY TIME DURING CONSTRUCTION, DRYING THE INSULATION IS NOT ACCEPTABLE. SEAL ANY TEARS OR JOINTS OF INTERNAL FIBERGLASS INSULATION. REMOVE DEBRIS FROM CEILING/RETURN AIR PLENUM INCLUDING DUST. AN INDEPENDENT, PROFESSIONAL DUCT CLEANING COMPANY SHALL VACUUM CLEAN ANY DUCTWORK CONNECTED TO HVAC UNITS THAT WERE OPERATED DURING THE CONSTRUCTION PERIOD AFTER NEW FILTERS ARE INSTALLED AND PRIOR TO TURNING SYSTEM OVER TO THE OWNER. SUBMIT WRITTEN REPORT FROM DUCT CLEANING COMPANY UPON COMPLETION OF WORK. 27. ALL ROOF WORK TO BE PERFORMED BY LANDLORD'S ROOFING CONTRACTOR. 28. COORDINATE LOCATION AND MOUNTING HEIGHTS OF TEMPERATURE SENSORS WITH BAS DRAWINGS AND ARCHITECT PRIOR TO INSTALLATION. 29. PROVIDE SEVEN-DAY PROGRAMMABLE THERMOSTAT FOR NEW ROOFTOP EQUIPEMENT. 30. DUCT INSULATION SHALL BE A MINIMUM OF R7 (INSTALLED) FOR DUCT INSTALLED ABOVE CEILING OR ON EXTERIOR OF THE BUILDING. 31. DUCT GAUGES SHALL BE PER 1994 SMC TABLE 6. 32. OUTSIDE AIR INTAKE SHALL BE A MINIMUM OF 10' FROM EXHAUST OUITLET. 33. CABLE OPERATED DAMPER TO BE UTILIZED WHEREVER A MANUAL VOLUME DAMPER IS INSTALLED ABOVE HARD LID CEILING. SEISMIC NOTES: 1. RECTANGULAR DUCTWORK WITH A CROSS-SECTIONAL AREA OF 6 SQ. FT. AND LARGER, AND SUSPENDED MORE THAN 12" FROM POINT OF CONNECTION TO STRUCTURE TO TOP OF DUCT SHALL BE BRACED IN TWO DIRECTIONS (90' OPPOSING) USING ROD OR STRAP OF SAME LOAD CHARACTERISTICS AS PRIMARY SUSPENSION ROD OR STRAP. 2. DUCTWORK SHALL HAVE TRANSVERSE BRACING AT MAXIMUM 3C-0" ON CENTER AND WITHIN 48" OF CHANGE IN DIRECTION AND LONGITUDINAL BRACING AT MAXIMUM 60'-0" ON CENTER. 3. CEILING DIFFUSERS AND GRILLES SHALL BE SECURED TO A STRUCTURAL ELEMENT USING A 12 GAUGE CEILING SUSPENSION WIRE. REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING - NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES 8c HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J -BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. CORRECTION LTR# RECEIVED CITY OF TUKWILA AUG 0 8 2013 PERMIT CENTER (i) nal tto 0 mia 0 0 2808 Fairmount Street LO 0 1-1 CD CO © Good Fulton & Farrell 2006 HENDERSON ENGINEERSN 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 9723866888 FAX 9723866887 1350000662 WA. CORPORATE NUMBER:1754 EXPIRES 06/30/14 TH RL TG BT BM LJ Z CD No. Date Item REVISIONS Drawn Checked Approved MECHANICAL PLAN SECOND FLOOR Project No. 1 3007.00 Date PERMIT - 06.24.1 3 Last Revision M - 1 KENNETH L. BIESMA ❑ 0 PARKING DECK J r L r1)1 HIGH ROOF 0 THEATRE ABOVE ❑ EXTERIOR WALKWAY L11 r1r STAIRS L LANDLORD TRASH MECHANICAL ROOF PLAN SCALE: 1 /8"=1'-0 ROOF BELOW ROOF BELOW REVIEWED FOR CODE COMPLIANCE APPROVED AUG 192013 City of Tukwila BUILDING DMVISION J MECHANICAL KEY NOTES: NEW RTU MOUNTED ON NEW ROOF CURB. COORDINATE EXACT LOCATION WITH ARCHITECTURAL DRAWINGS. 20 SEE P -1R SHEET FOR NATURAL GAS PIPING DETAILS. 30 SEE P -1R SHEET FOR CONDENSATE PIPING DETAILS. ® BAS CONTRACTOR TO FURNISH AND INSTALL CO2 SENSOR IN RETURN AIR PLENUM. COORDINATE INSTALLATION WITH MECHANICAL CONTRACTOR. REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING — NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J—BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. REFER TO DIVISION 2500 IN SPECIFICATIONS FOR ADDITIONAL SCOPE OF WORK. REFER TO ADT 1.10, ADT 1.20 AND CAM 1.20 AND AV 1.10 FOR ADDITIONAL SCOPE. NOTE: GENERAL CONTRACTOR TO CONFIRM LAYOUT OF EQUIPMENT WITH EXISTING EQUIPMENT LOCATED ON ROOF FOR OTHER TENANTS. GENERAL CONTRACTOR TO NOTIFY ENGINEER IF EXISTING EQUIPMENT IS T00 CLOSE TO PROPOSED NEW EQUIPMENT TO ALLOW FOR CODE REQUIRED AND MANUFACTURERS RECOMENDED CLEARANCES. NOTE: SEAL AND FLASH ALL ROOF PENETRATION AS PER ROOFING MFR. REQUIREMENTS AND SMACNA DETAILS REFERENCED ON ARCHITECTURAL DRAWINGS. ALL ROOF PENETRATIONS TO BE MADE BY ROOFING SUB—CONTRACTOR. NOTE: GENERAL CONTRACTOR SHALL USE LANDLORD'S ROOFING CONTRACTOR TO MAKE ALL ROOF PENETRATIONS, FLASHING, AND REPAIRS TO MAINTAIN ROOF WARRANTY. NOTE: REFER TO P -1R FOR CONDENSATE AND GAS PIPING ON ROOF AND E -1R FOR POWER ON ROOF. 13 I Iq RECEIVED CITY OF TUKWILA AUG 0 8 2013 U) cu s CO 0 0 0 2808 Fairmount Street O co Dallas, Texas 75201 © Good Fulton & Farrell 2006 HENDERSON ENGINEERS_ 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM 09 OD OD Q-100 w F O) O w- < z f- wz Li.‹ U —I ZI-I-- — � Z 0 0(f) CO No. Date Item REVISIONS NL Drawn TM Checked TM Approved MECHANICAL ROOF PLAN PERMIT CENTER Project No. 13007.00. Date PERMIT — 06.24.13 Last Revision M-1 R KENNETH L. BIESMA BUILDING HEATING AND COOLING LOADS OUTSIDE AIR REQUIREMENTS DESIGN COOLING CAPACITY (MBH) SAFETY FACTOR (%) PROJECT: TCS - Tukwila WA LOCATION: Tukwila WA CLIENT: TCS JOB NUMBER: 1350000662 DATE: 7/18/2013 CALCULATED BY: Scott Walter 955.1 Ventilation Zone Space Use Category People Outdoor Air Rate [Rp] (CFM/person) Default Occupant Density (#/1000 ft2) Default Zone Populatioon (people) Actual Population Override (people) Zone Population [Pz] (people) Area Outdoor Air Rate [Ra] (cfm/ft2) Zone Floor Area [Az] (ft2) Breathing Zone Outdoor Airflow [Vbz] (CFM) Zone Air Distribution Effectiveness [Ez] Zone Outdoor Airflow [Voz] (CFM) Sales Floor Sales (except as below) 7.5 15 287.1 275 275 0.12 19141 4359 0.8 5449 store manager Office space 5.0 5 0.6 1.8 1 0.06 121 10 0.8 13 general manager Office space 5.0 5 0.4 80 0 0.06 81 7 0.8 9 pos/gen Office space 5.0 5 0.4 ' 15 0 0.06 79 7 0.8 8 lockers/supply Office space 5.0 5 0.6 12.0 1 0.06 110 9 0.8 12 breakroom Breakrooms (office) 5.0 50 12.4 RTU -3 12 0.12 248 92 0.8 115 hallway Corridors 0.0 0 0.0 180.4 0 0.06 120 7 0.8 9 rr's/janitor Not regularly occupied 0.0 0 0.0 480/3 0 0 344 0 0.8 0 stockroom Warehouses 0.0 0 0.0 62.1 0 0.06 2335 140 0.8 175 electirc room Not regularly occupied 0.0 0 0.0 1365 0 0 155 0 0.8 0 comm Not regularly occupied 0.0 0 0.0 0.8 0 0 79 0 0.8 0 entry vestibule Main entry lobbies 5.0 10 1.3 _ I -- 1 0.06 125 14 0.8 17 PROJECT TOTALS 291 LGH072H4B 22938 100% 5807 0.8 2.0/1.0 75.6 BUILDING HEATING AND COOLING LOADS CALCULATED COOLING CAPACITY (MBH) DESIGN COOLING CAPACITY (MBH) SAFETY FACTOR (%) CALCULATED HEATING CAPACITY (MBH) DESIGN HEATING CAPACITY (MBH) SAFETY FACTOR (%) 744.4 839.3 113% 955.1 1272 133% MOCP ROOFTOP UNIT SCHEDULE (NATURAL GAS HEAT) MARK MARK MANUFACTURER MODEL NOMIAL TONNAGE ECON CYCLE SUPPLY FAN COOLING COIL HEATING COIL NOTES MIN. 0/A CFM MCA MOCP V/PH WEIGHT (LBS) NOTES CFM ESP (IN) HP/ BHP EAT LAT TH (MBH) SH (MBH) IEER EFF (EER) MIN. INPUT (MBH) MIN. OUTPUT (MBH) EFF. (%) MIN. NO. STAGES (DB) (WB) (DB) (WB) RTU -1 LENNOX LGH180H4B 15 100% 6000 1.8 5.0/4.8 76.5 62.1 55.0 55.0 180.4 138.9 13.7 12.0 360 288 80 2 PERFORATED 1365 42 45 480/3 2505 A,B,C,D,E,F,G,H,I,J,K,L,M,N,O RTU -2 LENNOX LGH180H4B 15 100% 6000 1.8 5.0/4.8 76.5 62.1 55.0 55.0 180.4 138.9 13.7 12.0 360 288 80 2 WRG1 1365 42 45 480/3 2505 A,B,C,D,E,F,G,H,I,J,K,L,M,N,O RTU -3 LENNOX LGH180H4B 15 100% 6000 1.8 5.0/4.8 76.'5 62.1 55.0 55.0 180.4 138.9 13.7 12.0 360 288 80 2 1365 42 45 480/3 2505 A,B,C,D,E,F,G,H,I,J,K,L,M,N,O RTU -4 LENNOX LGH180H4B 15 100% 6000 1.8 5.0/4.8 76.5 62.1 55.0 55.0 180.4 138.9 13.7 12.0 360 288 80 2 1365 42 45 480/3 2505 A,B,C,D,E,F,G,H,I,J,K,L,M,N,O RTU -5 LENNOX LCH048H4 4 100% 1600 0.8 2.0/0.6 75.0 60.0 55.0 55.0 44.9 39.3 -- 12.8 -- -- -- -- -- 14 20 480/3 806 A,B,C,D,E,F,H,I,J,K,L,M,N,O RTU -6 LENNOX LGH072H4B 6 100% 2400 0.8 2.0/1.0 75.6 61.8 55.0 55.0 72.8 56.8 13.5 12.0 150 120 80 2 360 19 25 480/3 960 A,B,C,D,E,F,G,H,I,J,K,L,M,N,0 NOTES: * CONTACT LOCAL LENNOX SUPPLIER FOR PRICING. FOR ADDITIONAL INFORMATION CONTACT STEVE FRICKE AT LENNOX NATIONAL ACCOUNTS, (800) 367-6285. A. EQUIPMENT CAPACITIES LISTED SHALL BE NET COOLING REQUIREMENTS AT ENTERING AIR CONDITIONS LISTED. B. SPECIFIED FAN ESP INCLUDES ONLY LOSSES FOR DUCTWORK AND AIR DEVICES DOWNSTREAM OF THE UNIT. IT DOES NOT INCLUDE LOSSES DUE TO IMPROPERLY MAINTAINED OR NON-SPECIFIED AIR FILTERS. C. EQUIPMENT SIZED FOR 95F AMBIENT TEMPERATURE. D. PROVIDE 2", 30% EFFICIENT PLEATED THROWAWAY AIR FILTERS. E. PROVIDE WITH FACTORY -INSTALLED HUMIDITROL DEHUMIDIFICATION SYSTEM. F. PROVIDE MODULATING SINGLE POINT ENTHALPY ECONOMIZER TO ALLOW FOR 100 PERCENT ECONOMIZER MODE. G. PROVIDE WITH FACTORY INSTALLED POWER EXHAUST. H. ELECTRICAL DISCONNECT SWITCH BY DIVISION 16. I. PROVIDE GFCI DUPLEX RECEPTACLE FACTORY MOUNTED ON UNIT FOR FIELD WIRING. J. PROVIDE WITH HAIL GUARD. K. FURNISH MANUFACTURERS CO2 SENSOR FOR FIELD INSTALLATION. L. FURNISH WITH FACTORY INSTALLED SMOKE DETECTORS IN SUPPPLY AND RETURN AIR DUCTS. M. STARTERS FOR ALL MOTORS SHALL BE FURNISHED INTEGRAL WITH UNIT. N. UNIT SHALL BE SUPPLIED WITH FACTORY SUPPLIED TEMPERATURE CONTROLS CAPABLE OF INTERFACING WITH THE BUILDING AUTOMATION SYSTEM. REFER TO BAS DRAWINGS FOR EXACT INFORMATION RELATED TO CONTROLS. 0. PROVIDE NEW 14" HIGH ROOF CURB. GENERAL NOTE: GC SHALL CONTRACT WITH AND SCHEDULE TCS VENDOR 13 (ENTEK) TO PROVIDE COMMISSIONING OF THE HVAC SYSTEM. GC SHALL COORDINATE THE SCHEDULE OF THIS WORK WITH THE TCS PROJECT MANAGER, DIVCON, ENTEK, AND THE HVAC SUBCONTRACTOR. COMMISSIONING GENERALLY TAKES PLACE DURING STORE SET UP (AFTER TURN -OVER). GC SHALL CONFIRM EXACT DATES WITH TCS PROJECT MANAGER. ENTEK, DIVCON AND THE HVAC SUBCONTRACTOR MUST BE PRESENT THE FULL DAY THAT COMMISSIONING OCCURS TO TROUBLESHOOT ANY ISSUES THAT ARISE. GC SHALL PROVIDE TCS WITH THE COMMISSIONING REPORT FROM ENTEK AND SHALL SCHEDULE THE FINAL TEST AND BALANCE FOR AFTER FINAL COMMISSIONING IS COMPLETE. GRILLE, REGISTER AND DIFFUSER SCHEDULE MARK MARK MANUFACTURER MODEL FACE TYPE MOUNTING LOCATION FACE SIZE (IN) MAX. NC MAX. PRESS. DROP (IN. W.C.) NOTES CSD1 TITUS TDC SQUARE LOUVER CEILING 9 x 9 25 DIRECT 0.1 A,B,C,D,H,Q CSD2 TITUS PSS PERFORATED CEILING 24 x 24 25 0.8 0.1 A,B,C,D,H,Q CSD3 TITUS FL -10 -JT SLOT CEILING 1" - 1 SLOT (48") 25 0.1 D,H,J,K,M,N,P,Q DSR1 TITUS 300 LOUVER DUCT / WALL SEE PLAN 25 0.1 D,E,F,G,J,Q CRG1 TITUS PAR PERFORATED CEILING SEE PLAN 25 0.05 D,G,H,Q CRG2 TITUS FL -10 SLOT CEILING 1"-1 SLOT 25 0.05 D,L,N,Q,P CEG1 TITUS 50F EGGCRATE CEILING 9 x 9 25 0.05 D,G,H,Q WRG1 TITUS 350 LOUVER WALL SEE PLAN 25 0.05 E,G,Q NOTES: A. NECK SIZE SHOWN ON DRAWINGS. B. 4 -WAY THROW PATTERN UNLESS OTHERWISE SHOWN ON DRAWINGS. C. BRANCH DUCT SIZE SHALL BE SAME AS NECK SIZE UNLESS OTHERWISE SHOWN ON DRAWINGS. D. WHEN INSTALLED IN CEILING OR SOFFITS, PROVIDE BAKED ENAMEL FINISH, WHITE TO MATCH CEILING COLOR. FOR EXPOSED DUCT MOUNTING, FINISH SIMILAR TO DUCT. E. FRONT BLADES PARALLEL TO LONG DIMENSION. F. DOUBLE DEFLECTION BARS SHALL BE ADJUSTABLE. G. PROVIDE NECK FOR DUCT CONNECTION. H. FRAME TYPE TO MATCH CEILING CONSTRUCTION, COORDINATE WITH ARCHITECTURAL REFLECTED CEILING PLAN. J. PROVIDE OPPOSED BLADE DAMPER ADJUSTABLE FROM FACE OF DEVICE. K. PROVIDE WITH TITUS FBPI INSULATED PLENUM OR APPROVED EQUAL. L. PROVIDE WITH INSULATED RETURN AIR LIGHT SHIELD, MODEL FBRI OR APPROVED EQUAL. M. PROVIDE YOUNG REGULATOR CO. MODEL 270-301 REMOTE CABLE CONTROL THROUGH FACE OF DIFFUSER OR GRILLE. N. INSTALL WITH NO EXPOSED MOUNTING SCREWS. P. PROVIDE TITUS BORDER TYPE 22 WITH CONCEALED MOUNTING BRACKETS. SLOT PLENUMS SHALL BE PROVIDED FOR BORDER TYPE 22. Q. EXCLUSIVE PRE -APPROVED MANUFACTURERS ARE TITUS AND KRUEGER ONLY. PROVIDE EXHAUST- FAN SCHEDULE MARK MANUFACTURER MOUNTING MODEL CFM ESP (IN) DRIVE (BELT/DIRECT) MIN. HP FAN RPM ELECTRICAL V/PH NOTES EF -1 GREENHECK ROOF G -123-A 1200 0.8 DIRECT 1/2 1725 120/1 A, B, C, E, F EF -2 GREENHECK ROOF G -098-A 500 0.8 DIRECT 1/4 1725 120/1 A, B, C, D NOTES: : A. MOUNT UNIT ON MINIMUM 14" HIGH CURB. B. PROVIDE FACTORY MOUNTED DISCONNECT SWITCH. C. PROVIDE WITH SPEED CONTROL. D. INTERLOCK FAN WITH RESTROOM OCCUPANCY SENSORS. E. INTERLOCK FAN WITH THERMOSTAT. THERMOSTAT SHALL BE SET TO 85F AND SHALL BE INDEPENDENT OF THE TEMPERATURE CONTROLS SYSTEM. F. NORMALLY OFF, ONLY ENERGIZES DURING POWER FAILURE. MECHANICAL LEGEND AFF ABOVE FINISHED FLOOR CFM CUBIC FEET PER MINUTE DDC DIRECT DIGITAL CONTROL EA EXHAUST AIR GPM GALLONS PER MINUTE IN. WC INCHES OF WATER COLUMN MBH 1000 BTU PER HOUR MC MECHANICAL CONTRACTOR NC NOISE CRITERIA OA OUTSIDE AIR RA RETURN AIR SA SUPPLY AIR UNO UNLESS NOTED OTHERWISE W/ WITH W/O WITHOUT ----- Jr Jr Jr N IN Jr N it i Jr IMINI.1IIIII A NEW DUCTWORK OR EQUIPMENT SHOWN HEAVY LINE WEIGHT NEW INSULATED DUCTWORK SHOWN HEAVY LINE WEIGHT WITH LIGHT DASHED LINE WEIGHT BRANCH DUCT WITH 45' RECTANGLE -ROUND BRANCH FITTING AND MANUAL VOLUME DAMPER ELBOW WITH TURNING VANES MANUAL VOLUME DAMPER RETURN, EXHAUST, OR OUTSIDE AIR DUCT UP RETURN, EXHAUST, OR OUTSIDE AIR DUCT DOWN SUPPLY AIR DUCT UP SUPPLY AIR DUCT DOWN EQUIPMENT WITH FLEXIBLE DUCT CONNECTION Dig -0E1 SIZE, TYPE, CFM OF DIFFUSER, REGISTER OR GRILLE 10"0 10"0 CSD -1 CSD -1 450 450 OT THERMOSTAT p TEMPERATURE SENSOR CO CARBON DIOXIDE SENSOR HUMIDITY SENSOR DETAIL REFERENCE UPPER NUMBER INDICATES DETAIL NUMBER LOWER NUMBER INDICATES SHEET NUMBER CONNECTION POINT OF NEW WORK TO EXISTING EQUIPMENT DESIGNATION AND NUMBER MECHANICAL NOTE DESIGNATION LANDLORD REQUIREMENTS: 1. FURNISH AIR -BALANCING REPORTS FOR HVAC WORK BY CERTIFIED THIRD PARTY BALANCE COMPANY. THE REPORT SHALL BE ISSUED NO MORE THAN 50 DAYS AFTER OPENING. REFER TO SPECIFICATIONS FOR FURTHER REQUIREMENTS. 2. ALL STEEL SUPPORTS TO BE ATTACHED TO THE STEEL STRUCTURE SHALL BE CLIPPED, NOT WELDED. 3. GENERAL CONTRACTOR SHALL PROVIDE A FIRE WATCH AND PORTABLE FIRE EXTINGUISHER (MINIMUM SIZE 2A.208C), WHENEVER ANY WELDING IS DONE WITHIN THE DEMISED PREMISES. THE PERSON PERFORMING THE FIRE WATCH SHALL REMAIN IN THE TENANT SPACE FOR AT LEAST ONE HOUR AFTER THE COMPLETION OF ANY WELDING. 4. ALL ROOFING, WEATHERPROOFING, FLASHING AND PATCHING SHALL BE PERFORMED BY THE LANDLORDS ROOFING CONTRACTOR AND BE PART OF THIS CONTRACT. 5. PROVIDE TEMPORARY WEATHERPROOFING FOR ALL ROOF PENETRATIONS UNTIL LANDLORD'S ROOFING CONTRACTOR HAS MADE THE FINAL PATCH. 6. ALL EQUIPMENT IS TO BE SUPPORTED FROM STRUCTURAL MEMBERS. NO WEIGHT CAN BE PLACED ON THE ROOFING MATERIALS OR INSULATION. 7. ROOF TOP EQUIPMENT CANNOT EXCEED THE TOP OF THE ROOF SCREENS IN HEIGHT. 8. PROVIDE A MINIMUM OF 12" CLEARANCE FROM THE TOP OF THE ROOF -MOUNTED CURB TO THE TOP FINISHED SURFACE OF THE ROOF. 9. PRIOR TO MAKING ANY PIPE OR DUCT ROOF PENETRATION AND/OR POSITIONING OF ANY EQUIPMENT ON THE ROOF ALL THE PROPOSED LOCATIONS AND/OR PENETRATIONS SHALL MATCH LOCATIONS, AS INDICATED ON THE DRAWING APPROVED BY LANDLORD'S CONSTRUCTION FIELD COORDINATOR. 10. TENANTS STORE SPACE NUMBER SHALL BE PERMANENTLY STENCILED ON ONE SIDE OF THE ROOF MOUNTED HVAC UNIT WITH MINIMUM THREE-INCH HIGH LETTERS. 11. NO WOOD SLEEPERS OF ANY KIND SHALL BE ALLOWED. 12. NO ROOF MOUNTED EQUIPMENT OR PENETRATIONS SHALL BE LOCATED OUTSIDE THE TENANTS DEMISED PARTITIONS. GENERAL NOTES: 1. WORK SHALL COMPLY WITH STATE AND LOCAL CODES 2. INTERRUPTION OF ELECTRICAL SERVICES OR EXISTING MECHANICAL SYSTEMS SHALL BE SCHEDULED IN ADVANCE AND ONLY AT TIMES APPROVED BY BUILDING OWNER. 3. PROVIDE LABOR, MATERIAL, TOOLS, APPURTENANCES AND EQUIPMENT REQUIRED TO PROVIDE COMPLETE AND OPERATIONAL MECHANICAL AND PLUMBING SYSTEMS SHOWN 4. PROVIDE CUTTING AND PATCHING AS REQUIRED FOR INSTALLATION OF NEW WORK. PATCHING SHALL MATCH ADJACENT FINISH, COLOR AND MATERIAL TO SATISFACTION OF OWNER. 5. FABRICATE RECTANGULAR AND ROUND DUCTWORK FITTINGS AND SUPPORTS IN ACCORDANCE WITH LATEST SMACNA "HVAC DUCT CONSTRUCTION STANDARDS." 6. INSTALLATION INSTRUCTIONS FOR LISTED EQUIPMENT SHALL BE MADE AVAILABLE TO BUILDING INSPECTOR AT TIME OF INSPECTION. 7. DUCT WORK AND PIPING SHALL BE SEISMICALLY BRACED AND SUPPORTED PER LOCAL CODE AND SMACNA STANDARDS. REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING - NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, LIGHTS, J -BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 192013 City of Tukwila BUILDING DIVISION M I et RECEIVED CITY OF TUKWILA AUG 0 8 2013 PERMIT CENTER y G) \ ~ O,N E V egt 7-1F 74 N cJ 111) `""I '""I UUn 01 01 H4 M M "• " CIS U 0 u 0 0 CD 2808 Fairmount Street CD C!) O CV LO is © Good Fulton & Farrell 2006 HENDERSON ENGINEERS_ 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 Fax 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM J I- -I 00 UJ < J :E 07Dw owoQ C7- Z wz U w U J ZF-H� zOOH LLJU) (%) ~- N) N) LO 08/02/2013 ADDENDUM 1 No. Date Item REVISIONS HVAC LEGEND AND SCHEDULES Project No. 13007.00 Date PERMIT - 06.24.13 Last Revision M - 2 45' HIGH EFFICIENCY TAKE—OFF WITH SQUARE TO ROUND FITTING SHEETMETAL DUCT NOTE: PROVIDE GREY OR ALUMINIZED DUCT —'4--- FASTEN TO STRUCTURE TAPE SECURING AND SEALING FLEXIBLE DUCT OR EXTERNAL DUCT INSULATION FLEXIBLE DUCT (MAXIMUM OF 5'-0" WITH ONE 90' ELBOW) 1" BAND CLAMP APPLY BAND OVER DOUBLE SIDED TAPE TO COMPRESS AND SEAL FLEX TO OUTSIDE OF COLLAR (STAINLESS STEEL) BAND 1/2" MINIMUM WIDTH) CONNECT TO AIR DEVICE NECK UNLESS OTHERWISE NOTED FLEX DUCT IS SAME SIZE AS DIFFUSER NECK SPLIT DOUBLE SIDED TAPE BALANCING DAMPER CONTROLLED BY WORM -GEAR OPERATOR MOUNTED IN FACE OF GRILLE ON DIFFUSER (TYP) NOTES: 1. CUT OPENING IN SHEETMETAL DUCT ACCURATELY. INSTALL 45' LATERAL TO AVOID VISIBLE OPENINGS AND SECURE FITTING SUITABLY FOR PRESSURE CLASS. 2. INSTALL FLEXIBLE DUCT IN AS STRAIGHT A RUN AS POSSIBLE. USE LONG RADIUS BENDS WHERE POSSIBLE. PULL DUCT TIGHT AT BOTH ENDS AND SECURE WITH METAL CLAMPS. 3. PROVIDE EXTENSION RODS TO ACCOMMODATE INSULATION, PULL TO EDGE OF DUCTWORK AS REQUIRED AND SEAL TO MAINTAIN VAPOR BARRIER. 4. INSTALL LOCKING QUADRANT TO HANDLE ON BOTTOM OF DUCT FOR EASE OF SERVICE. 45°LATERAL FLEXIBLE DUCT TAKE OFF DETAIL NO SCALE SUPPLY AIR DUCT AIR FLOW BALANCING DAMPER KENNETH L. BIESMA INVERTED DUCT COLLAR AIR FLOW 45' ENTRY COLLAR SUPPLY AIR REGISTER WITH INTEGRAL VOLUME DAMPER DUCT MOUNTED REGISTER DETAIL NO SCALE ROOFTOP HVAC UNIT/ 0 v DUCT SIZE 0/ n n PROVIDE INSULATION TO INFILL CURB FOR SOUND ATTENUATION RE: ROOF CURB DETAIL THIS SHEET RETURN AIR DUCT SUPPLY AIR DUCT CEILING CANVAS CONNECTION (TYPICAL) 'NOTES: I. PROVIDE OPENING THROUGH ROOF AND ROOF DECK INSULATION NO LARGER THAN REQUIRED TO ALLOW DUCTS TO PASS THROUGH. REFER TO PLANS FOR DUCT SIZES. TRANSITION AS REQUIRED IN ROOF CURB TO RTU SUPPLY AND RETURN OPENINGS. PROVIDE SLOPED ROOF CURB TO INSTALL ROOFTOP UNIT LEVEL TO ENSURE PROPER DRAINAGE. COORDINATE ROOF SLOPE WITH ARCHITECTURAL. FLASH AND COUNTER FLASH ROOF PENETRATIONS, ETC. TO ENSURE WEATHER TIGHT INSTALLATION. ROOFTOP UNIT WITH DUCTWORK DETAIL NO SCALE FINISHED SLAB HANGER STRAP SEE NOTE 1. 1" MIN. SHEET METAL SCREWS SEE NOTE 2. (TYP) NOTES: 1. USE THREADED ROD FOR ALL DUCTS LARGER THAN 60" WIDE. 2. SHEET METAL SCREWS MAY BE OMITTED IF HANGER STRAP IS CONTINUOUS AND LOOPS UNDER ENTIRE DUCT. RECTANGULAR DUCT SUPPORT CONCRETE DECK DETAIL NO SCALE SECURE SEISMIC BRACKET WITH S.S. SCREWS SEALING MATERIAL SHEET METAL FLASHING RECEIVER WOOD NAILER — OMIT WHERE WOOD NOT ALLOWED BY LOCAL BUILDING CODE HIGH—DOMED, CAPPED, GASKETED / FASTENERS (APPROX. 18" O.C. AND MINIMUM TWO FASTENERS PER SIDE) ROOF SEISMIC RESTRAINT BRACKET CURB ROOFTOP UNIT BASE RAIL SHEET METAL COUNTERFLASHING FILL ENTIRE CURB SPACE, ALTERNATING LAYERS OF 2", 3# DENSITY, RIGID, ACOUSTICAL FIBER BOARD AND 5/8" SHEETROCK. EXTENSION OF FIELD PLIES ABOVE HEAD OF CANT (NOT SHOWN FOR CLARITY) SPECIFIED MEMBRANE BASE FLASHING APPROX. SPECIFIED ROOF MEMBRANE ` f 4" COVERBOARD INSULATION THERMAL INSULATION ROOF DECK SECURE CURB TO ROOF STRUCTURE CAULK OPENING AROUND DUCT NOTES: 1. CUT METAL DECKING TO ALLOW CURB INSTALLATION ON STEEL FRAMING. AFTER CURB IS SET IN PLACE, TRIM REMAINING METAL DECKING AND INSTALL WITHIN CURB. TACK WELD DECKING TO SUPPORT STEEL. DO NOT WELD INTERIOR DECKING TO ROOF CURB. PROVIDE ADDITIONAL CROSS FRAMING TO SUPPORT INTERIOR DECKING AND FILL MATERIAL AS REQUIRED. FOR RTU WITH NET WEIGHT UNDER 1,000 LBS CURB MAY BEAR ON METAL DECK FOR RTU WITH NET WEIGHT OVER 1,000 LBS CURB SHALL BEAR ON STEEL FRAMING FRAME CURB AND DECKING WITH STEEL ANGLE. COORDINATE WITH STRUCTURAL ENGINEER. SEISMIC ROOF CURB DETAIL NO SCALE FINISHED SLAB TWIST STRAP 16 GA. GALV. STEEL BAND 2"WIDE ROUND DUCT NOTES: LOAD RATED FASTENERS MAX. 24"0 1. FOR DUCTS LARGER THAN 36"93, USE TWO HANGER RODS, WIRES OR STRAPS TO SUPPORT DUCT FROM EACH SIDE. ROUND DUCT SUPPORT CONCRETE DECK DETAIL NO SCALE "S" CLIP CONNECTION BREAKAWAY JOINT SEE NOTE 2 ROOFTOP UNIT THREADED TEE, WITH EXTENDED NIPPLE AND CAP DISCHARGE AWAY FROM SERVICE AREAS OF UNIT OR WHERE SHOWN ON PLANS — til 1" MINIMUM ROOF 8LOWTHRU: A = GREATER OF 4" OR 1/2" PLUS ROOFTOP UNIT TOTAL PRESSURE IN INCHES—WATER COLUMN DRAWTHRU: B= 3" NOTES: 1. 1"0 MINIMUM PIPE SIZE OR SIZE PER DRAIN TAP IN UNIT. ROOFTOP CONDENSATE DRAIN TRAP NO SCALE METAL BAND OVER INSULATION (TYPICAL) HIGH EFFICIENCY TAKEOFF EXTERNALLY INSULATED, WITH VOLUME DAMPER AND DAMPER LOCK WITH EXTENSION FOIL TAPE AT INSULATION JOINT SEE NOTE 1. PRE—INSULATED FLEXIBLE DUCT AS REQUIRED, INSTALL PERMANENTLY SEALED AND SUPPORTED TO PREVENT KINKING AND SHARP TURNS EXTEND DUCTWORK OVER TOP OF CURB, SECURE DUCTWORK TO CURB NAILER SECURE CURB TO ROOF WITH SCREWS, PINS, OR BOLTS EXHAUST FAN WITH BIRDSCREEN SECURE EXHAUST FAN TO EXISTING ROOF CURB. PROVIDE ADAPTER AS REQUIRED EXISTING ROOF CURB ROOF INSULATION FASTEN ANGLE IRON SECURELY TO DUCT AND ROOF STRUCTURE INSULATED DUCT REFER TO ARCHITECTURAL DRAWINGS FOR ADDITION MOUNTING INFORMATION METAL BAND (TYPICAL) SEE NOTE 3. CEILING DIFFUSER AS SCHEDULED CEILING —TO BALANCING DAMPER AT BRANCH TAKEOFF. WORM GEAR OPERATOR MOUNTED IN PLAN VIEW BELOW. ROOF DECK REFER TO ARCHITECTURAL DRAWINGS COUNTER BALANCED BACKDRAFT (UNLESS NOTED OTHERWISE) DAMPER, SECURE TO DUCT FROM ABOVE TO ALLOW SERVICE OR REMOVAL OF DAMPER FROM ROOF EXHAUST DUCT UP THROUGH ROOF. DOWNBLAST EXHAUST FAN DETAIL NO SCALE SEE NOTE 2. PROVIDE 1/2" THICK INSULATION INTERNAL TO SLOT AS SHOWN OR FOIL BACKED MINERAL WOOL INSULATION EXTERNAL TO SLOT; SEAL FOIL TO SLOT WITH FIBER REINFORCED FOIL BACKED TAPE T—BAR ARRANGEMENT PER SCHEDULE WITH GRID FURNISHED AND INSTALLED BY OTHERS— NOTES: 1. EXTEND RIGID METAL DUCT SO THAT MAXIMUM FLEXIBLE DUCT LENGTH DOES NOT EXCEED 5'-0". PROVIDE RIGID 90' ELBOW WHERE REQUIRED TO KEEP FLEXIBLE DUCT WITHIN 5'-0" LENGTH LIMITATION. 2. PROVIDE RIGID ROUND—TO—OVAL TRANSITION WHEN PLENUM HAS OVAL CONNECTION. 3. FLEX DUCT NOT PERMITTED ABOVE GYP—BOARD CEILINGS E 4 O LAY -IN AND SLOT TYPE CEILING DIFFUSER DETAIL NO SCALE MOUNTING ANGLE TO OVERLAP WALL 1" MINIMUM ON ALL SIDES, SECURE MOUNTING ANGLE TO FIRE DAMPER SLEEVE (DO NOT CAULK) ACTUATOR MOUNTED OUTSIDE OF DUCT COMBINATION FIRE AND SMOKE DAMPER WITH RE—SETTABLE TEMPERATURE DEVICE 16"x16" ACCESS DOOR 12" MAX NOTES: 1. INSTALL FIRE/SMOKE DAMPER PER MANUFACTURERS 2. MAKE WALL OPENING 1/8" PER FOOT LARGER THAN REQUIRED, MAXIMUM 1'. 3. DIVISION 15 CONTRACTOR SHALL PROVIDE CONTROL DAMPERS. DIVISION 16 CONTRACTOR SHALL PROVIDE DAMPERS. FIRE AND SMOKE RATED WALL SEE NOTE 2. RECOMMENDATION AND NFPA STANDARDS DAMPER DIMENSIONS WITH 1/4" MINIMUM AIR CONNECTION TO ALL SMOKE POWER CONNECTION TO ALL PARALLEL BLADE RECTANGULAR FIRE/SMOKE DAMPER DETAIL NO SCALE SQUARE SHAFT FOR 1/4" DRIVE SOCKET/ NUTDRIVER CONNECT TO SUPPORTING STRUCTURAL MEMBER HIGH EFFICIENCY TAKEOFF EXTERNALLY INSULATED, WITH VOLUME DAMPER AND DAMP, IT EXTE sf64 biANDWITH INSULATION (TYPICAL) INSULATED DUCT TO WORM GEAR OPERATOR MOUNTED IN FACE OF GRILLE OF DIFFUSER (TYP) WORM GEAR OPERATOR MOUNTED IN FACE OF GRILLE OR DIFFUSER (TYP). PLAN VIEW LINEAR SLOT DIFFUSER CABLE OPERATED DAMPER DETAIL NO SCALE J U LLI D m F- 0'— I 0 - 0 0 U) W � � ZO0� E N 11 < LL,ao cn 21N-1 wa =LLT U) > u v DUCT SIZE u n n w L.] N N I- 0 D 0 ....- n CONNECT TO SUPPORTING STRUCTURAL MEMBER 1/2 CLEARANCE MAXIMUM VERTICAL HANGER LONGITUDINAL HANGER ONE EACH SIDE OF DUCT HORIZONTAL BRACE Q BOLTS EQUAL CL OF ANGLES 11 1" TYPICAL 4 SIDES INSULATION WHERE REQUIRED NOTES: 1. CABLE BRACES MAY BE USED FOR SEISMIC RESTRAINT IN LIEU OF ANGLE BRACES. CENTER SEISMIC BRACING FOR RECTANGULAR DUCTS NO SCALE REFER TO SECTION 01300 SUBMITTALS FOR REQUIREMENTS OF CEILING PLENUM COORDINATION DRAWING — NO WORK MAY START IN THE CEILING PLENUM SPACE UNTIL GC HAS AN APPROVED COORDINATION DRAWING SHOWING THE WORK OF ALL TRADES IN THE CEILING AREA THIS INCLUDES BUT IS NOT LIMITED TO THE SPRINKLER LINES & HEADS, CEILING HANGERS, FRAMING, & SUPPORTS, CONDUIT, DUCTS, DIFFUSERS, I LIGHTS, J—BOXES, CONTROL JOINTS, LOW VOLTAGE DEVICES SUCH AS SPEAKERS, CAMERAS, SECURITY SYSTEM DEVICES, ETC. REVIEWED FOR CODE COMPLIANCE APPROVED AUG 19 2013 City of Tukwila BUILDING DIVISION Kt3-119 RECEIVED CITY OF TUKWILA AUG 0 8 2013 PERMIT CENTER u) a) s 0 0.) 0 0 2808 Fairmount Street O N 1.0 N X H Er ea © Good Fulton & Farrell 2006 HENDERSON ENGINEERSN 15851 NORTH DALLAS PARKWAY, SUITE 240 ADDISON, TX 75001 TEL 972 386 6888 FAX 972 386 6887 www.hei-eng.com 1350000662 WA. CORPORATE NUMBER: 1754 EXPIRES 06/30/14 TH RL TG BT BM I- J m co Z Q °o 00 LLI CL LL I z ULL_I U —I zH-F� ZOO C N) No. Date Item REVISIONS Drawn Checked Approved HVAC DETAILS Project No. 13007.00 Date PERMIT — 06.24.13 Last Revision M - 3