Loading...
HomeMy WebLinkAboutPermit M13-120 - AVEDA - ALTERATIONAVEDA 211 S 0 UTH CENTER MALL M13-120 City o0fukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Inspection Request Line: 206-431-2451 Web site: http://www.TukwilaWA.gov MECHANICAL PERMIT Parcel No.: 9202470010 Address: 211 SOUTHCENTER MALL TUKW Project Name: AVEDA Permit Number: M13-120 Issue Date: 08/13/2013 Permit Expires On: 02/09/2014 Owner: Name: WESTFIELD PROPERTY TAX DEPT Address: PO BOX 130940 , CARLSBAD CA 92013 Contact Person: Name: GARY PALMER Address: PO BOX 23534 , EUGENE OR 97492 Email: PSCONSULTANTS@SBCGLOBAL.NET Contractor: Name: EVERGREEN REFRIGERATION LLC Address: 727 S KENYON ST , SEATTLE WA 98108 Contractor License No: EVERGRL954R2 Phone: 541-603-4191 Phone: 206 763-1744 Expiration Date: 01/06/2014 DESCRIPTION OF WORK: INSTALLATION OF NEW AIR HANDLER WITH HEAT AND VENTILATION SYSTEM INTO EXISTING REMODELED SPACE. SEE ATTACHED SCOPE OF WORK. Value of Mechanical: $23,000.00 Type of Fire Protection: UNKNOWN Electrical Service Provided by: Permit Center Authorized Signature: Fees Collected: $475.13 International Mechanical Code Edition: 2012 Date: V �� I hereby certify that I have read and examined this permit and know the same to be true and correct. All provisions of law and ordinances governing this work will be complied with, whether specified herein or not. The granting of this permit does not presume to give authority to violate or cancel the provisions of any other state or local laws regulating construction or the performance of work. I am authorized to sign and obtain this mechanical permit and agree to the conditions on the back of this permit. Signature: Print Name: 13u -- Date: cq t A3 This permit shall become null and void if the work is not commenced within 180 days from the date of issuance, or if the work is suspended or abandoned for a period of 180 days from the last inspection. Regio 1.1/1 Drinferl• !1A_1-4_7l11'i • • PERMIT CONDITIONS Permit No. M13-120 1: ***BUILDING DEPARTMENT CONDITIONS*** 2: No changes shall be made to the approved plans unless approved by the design professional in responsible charge and the Building Official. 3: All mechanical work shall be inspected and approved under a separate permit issued by the City of Tukwila Permit Center (206/431-3670). 4: All permits, inspection records, and approved plans shall be at the job site and available to the inspectors prior to start of any construction. These documents shall be maintained and made available until final inspection approval is granted. 5: Readily accessible access to roof mounted equipment is required. 6: All construction shall be done in conformance with the approved plans and the requirements of the International Building Code or International Residential Code, International Mechanical Code, Washington State Energy Code. 7: Remove all demolition rubble and loose miscellaneous material from lot or parcel of ground, properly cap the sanitary sewer connections, and properly fill or otherwise protect all basements, cellars, septic tanks, wells, and other excavations. Final inspection approval will be determined by the building inspector based on satisfactory completion of this requirement. 8: Manufacturers installation instructions shall be available on the job site at the time of inspection. 9: All plumbing and gas piping work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 10: All electrical work shall be inspected and approved under a separate permit issued by the City of Tukwila Building Department (206-431-3670). 11: VALIDITY OF PERMIT: The issuance or granting of a permit shall not be construed to be a permit for, or an approval of, any violation of any of the provisions of the building code or of any other ordinances of the City of Tukwila. Permits presuming to give authority to violate or cancel the provisions of the code or other ordinances of the City of Tukwila shall not be valid. The issuance of a permit based on construction documents and other data shall not prevent the Building Official from requiring the correction of errors in the construction documents and other data. 12: ***FIRE DEPARTMENT CONDITIONS*** 13: The attached set of building plans have been reviewed by the Fire Prevention Bureau and are acceptable with the following concerns: 14: H.V.A.C. units rated at greater than 2,000 cfm require auto -shutdown devices. These devices shall be separately zoned in the alarm panel and local U.L. central station supervision is required. (City Ordinance #2328) 15: H.V.A.C. systems supplying air in excess of 2,000 cubic feet per minute to enclosed spaces within buildings shall be equipped with an automatic shutoff. Automatic shutoff shall be accomplished by interrupting the power source of the air -moving equipment upon detection of smoke in the main return -air duct served by such equipment. Smoke detectors shall be labeled by an approved agency for air -duct installation and shall be installed in accordance with the manufacturer's installation instructions. (IMC 606.1, 606.2.1) 16: Remote indicator lights are required on all above ceiling smoke detectors. (City Ordinance #2328) 17: Duct smoke detectors shall be capable of being reset from a single point near the alarm panel. (City Ordinance #2328) 18: Duct detectors shall send a supervisory signal only upon activation. (City Ordinance #2328) 19: All new fire alarm systems or modifications to existing systems shall have the written approval of The Tukwila Fire Prevention Bureau. No work shall commence until a fire department permit has been obtained. (City Ordinance #2328) (IFC 104.2) (ALL FIRE ALARM COMPONENTS TO BE TIED TO THE MAIN MALL FIRE ALARM PANEL.) 20: An electrical permit from the City of Tukwila Building Department Permit Center (206-431-3670) is required for this doc: IMC -4/10 M13-120 Printed: 08-13-2013 project. • • 21: All electrical work and equipment shall conform strictly to the standards of the National Electrical Code. (NFPA 70) 22: Contact The Tukwila Fire Prevention Bureau to witness all required inspections and tests. (City Ordinances #2327 and #2328) 23: Any overlooked hazardous condition and/or violation of the adopted Fire or Building Codes does not imply approval of such condition or violation. 24: These plans were reviewed by Inspector 511. If you have any questions, please call Tukwila Fire Prevention Bureau at (206)575-4407. 1111,1,3 Anfl Or�nle.d• !1G 1Z ',Al CITY OF TUKWILA Community Development Department Permit Center 6300 Southcenter Blvd, Suite 100 Tukwila, WA 98188 http://www.TukwilaWA.gov Mechanical Permit No. ti 1 3 0-0 Project No. \:)k3 --0S Date Application Accepted: 1 `)--( 3 Li Date Application Expires: (For office use only) MECHANICAL PERMIT APPLICATION Applications and plans must be complete in order to be accepted for plan review. Applications will not be accepted through the mail or by fax. **please print** SITE LOCATION King Co Assessor's Tax No.: Site Address: P44,14rA?O1i 1iJ e-O-Kr/C. -, LA KL 1 14 Suite Number: 3 re Floor: Tenant Name: /W PROPERTY OWNER Name: r ,(_rFt (t Address: it 470, wt LLSW1iQ . zLvb 1 ilii, T,-_,.. City:i_oe. 1c7J(4.0-1_State: Zip: e� C� CONTACT PERSON — person receiving all project communication Name: G+ ,.1, �gc.L.A. Address: p 0 a k 4--z? s T City: CsI.,.C4.C�C State: CA-- Zip:.1'7L Phone: ,..i' t (001) t ti s®1Faxx: `rt II 1 Email: S Co n S� 1� l'S ee''.6 CAto UG oQ \ , n. - 1D . New Tenant:[1� Yes ..No MECHANICAL CONTRACTOR INFORMATION Company Name: � �.�� Address: City: State: Zip: Phone: Fax: Contr Reg No.: Exp Date: Tukwila Business License No.: Valuation of project (contractor's bid price): $ a 3 1 0-00' Describe the scope of work in detail: ' KIS—PO-4_1 1/ w OF Arc -1-3 Al 2 1-eA0.% l. -C,2 t i -f E cry U C�..rrr tnJ e;KS7 �.�ro Ex, 5 TI ,-)6( 4 ,-c-uC-) Scoff iv- oDaAic Use: Residential: New ❑ Commercial: New �+ Fuel Type: Electric Li% Gas Replacement Replacement Other: H:1Applications1Forns-Applications On Line12011 Applications Mechanical Permit Application Revised 8-9-11.docx Revised: August 2011 bh Page 1 of 2 Indicate type of mechanical work being installed and the quantity below: Unit Type Qty Furnace <100k btu Furnace >100k btu S Floor furnace 1 Suspended/wall/floor mounted heater Appliance vent Repair or addition to heat/refrig/cooling system Air handling unit <10,000 cfm Unit Type Qty Air handling unit >10,000 cfm S Evaporator cooler 1 Ventilation fan connected to single duct Ventilation system Hood and duct Incinerator — domestic Incinerator — comm/industrial L /5 kv, c.c�-r►2-t t kw• Unit Type Qty Fire damper Diffuser S Thermostat 1 Wood/gas stove Emergency generator Other mechanical equipment Boiler/Compressor Qty 0-3 hp/100,000 btu 3-15 hp/500,000 btu 15-30 hp/1,000,000 btu 30-50 hp/1,750,000 btu 50+ hp/1,750,000 btu PERMIT APPLICATION NOTES - Value of construction — in all cases, a value of construction amount should be entered by the applicant. This figure will be reviewed and is subject to possible revision by the permit center to comply with current fee schedules. Expiration of plan review — applications for which no permit is issued within 180 days following the date of application shall expire by limitation. The building official may grant one extension of time for additional periods not to exceed 90 days each. The extension shall be requested in writing and justifiable cause demonstrated. Section 105.3.2 International Building Code (current edition). I HEREBY CERTIFY THAT I HAVE READ AND EXAMINED THIS APPLICATION AND KNOW THE SAME TO BE TRUE UNDER PENALTY OF PERJURY BY THE LAWS OF THE STATE OF WASHINGTON, AND I AM AUTHORIZED TO APPLY FOR THIS PERMIT. BUILDING OWNER OR AUTHORIZED Signature: Gv z- ' a rt ` ,�-1M CSL Print Name: Mailing Address: 1>0 g3S Date: 7/l Day Telephone: C(f/ , Cao -S.39.91 CIASec)-4-ts 49g H:\Applications\Forna-Applications On Line \2011 Applcations\Mechanical Permit Application Revised 8-9-1 I.docx Revised: August 2011 bh City State Zip Page 2 of 2 i • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT ParcelNo.: 9202470010 Permit Number: M13-120 Address: 211 SOUTHCENTER MALL TUKW Status: APPROVED Suite No: Applied Date: 07/02/2013 Applicant: AVEDA Issue Date: Receipt No.: R13-02353 Payment Amount: $380.10 Initials: WER Payment Date: 08/13/2013 02:26 PM User ID: 1655 Balance: $0.00 Payee: EVERGREEN REFRIGERATION LLC TRANSACTION LIST: Type Method Descriptio Amount Payment Check 006038 380.10 Authorization No. ACCOUNT ITEM LIST: Description Account Code Current Pmts MECHANICAL - NONRES 000.322.102.00.00 380.10 Total: $380.10 a,.... De..ei. +_na Printed: 08-13-2013 • City of Tukwila Department of Community Development 6300 Southcenter Boulevard, Suite #100 Tukwila, Washington 98188 Phone: 206-431-3670 Fax: 206-431-3665 Web site: http://www.TukwilaWA.gov RECEIPT Parcel No.: 9202470010 Permit Number: M13-120 Address: 211 SOUTHCENTER MALL TUKW Status: PENDING Suite No: Applied Date: 07/02/2013 Applicant: AVEDA Issue Date: Receipt No.: R13-02042 Payment Amount: $95.03 Initials: WER Payment Date: 07/02/2013 01:58 PM User ID: 1655 Balance: $380.10 Payee: GARY R PALMER (PHONE) TRANSACTION LIST: Type Method Descriptio Amount Payment Credit Crd VISA Authorization No. 055796 ACCOUNT ITEM LIST: Description 95.03 Account Code Current Pmts PLAN CHECK - NONRES 000.345.830 95.03 Total: $95.03 o.;.,.e,l. INSPECTION RECORD Retain a copy with permit INSP • PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 LI) - 12_0 Project: }a `j �,� Ps -I Type of Inspection: -' I Address: a-1 ‘ 50(t?,i-t n14 I( Date Called: Special Instructions: r� Li 1ve_ — : 071-2-13 —0 1 ± Date Wanted: C.91 � '- 18-13 p.m. Requester: Phone No: "!l7 — 5q3 -L-1/3(.., Approved per applicable codes. Corrections required 'prior to approval. alMENTS: ! ?t E 7.),tS-tk1 - pRiv; ,ol\ _A, d �,,j 0 --A /6,i P .t Datte: AJC;ke [ INSPECTION FEE REQ TIRED. Prior to next inspection, fee mus be id at 6300 Southcente lvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 1ti(3_/2O Project: A\%9A- Type/f Inspection: j(-- �H. c, ' / Ai .4/V Address: 2I1 S.c.) A -If Date Called: _ Special Instructions: Date Wanted: 1 '-an a.m., p.m. Requester: Phone No: Approved per applicable codes. Corrections required prior to approval. 7 COMMENTS: AoAS. jet 3 Ke �k 31---',0, A) Inspector: ct.i4_/ Dater, _ 7 I I REINSPECTION FEE REQUIRED. Prior to next inspection. fee must be paid at 6300 Southcenter Blvd., Suite 100. Call to schedule reinspection. INSPECTION NO. INSPECTION RECORD Retain a copy with permit ,3 -ice PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206) 431-3670 Permit Inspection Request Line (206) 431-2451 Proje -Jeo A Type of Inspection: 6 v c.A --i,A-� Address: f z11 SL J4A4 Date Called: ..----. Special Instructions:• J Date Wanted i/0 t I �� a.m. P.m. Requester: Phone No: Approved per applicable codes. LJ Corrections required prior to approval. COMMENTS: c-(o3r' X24 Inspect -9r:: o1/4)Ak) Dater ,-l0 - (3 REINSPECTION FEE REQUIRED. Prior to next inspection, fee must be paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection. INSPECTION RECORD Retain a copy with permit INSPECTION NO. PERMIT NO. CITY OF TUKWILA BUILDING DIVISION 6300 Southcenter Blvd., #100, Tukwila. WA 98188 (206)):431-367 Permit Inspection Request Line (206) 431-2451 YL M13 - azo Project Typtj 6 IUp6 14- N "4-e Com' 1 Ad ress: 1 Date Called: otc___-.0 ►nsJlkf L.(' A ed. 04 Special Instructions:Wanted_ Date 3 m p.m. Requester: ic A AZ .n !fit e.c4 . du (.1- t/J i C.. r /1 (J -� e �c1", �i vs T.--(- %SYDd i _ JApproved per applicable codes. QCorrections required prior to approval. f COMMENTS: p/A— otc___-.0 ►nsJlkf L.(' A ed. 04 37-j, II )Jeeo ;o ;Aslo ecl- ic A AZ .n !fit e.c4 . du (.1- t/J i C.. r /1 (J -� e �c1", �i vs T.--(- %SYDd i _ -----, 4 /? 7 REINSPECTION FEE REQUIR D. Prior to next inspectiort,(ee must be ) paid at 6300 Southcenter Blvd.. Suite 100. Call to schedule reinspection: Inspe or: Date 5' INSPECTION NUMBER INSPECTION RECORD Retain a copy with permit in/ 420 PERMIT NUMBERS CITY OF TUKWILA FIRE DEPARTMENT 444 Andover Park East, Tukwila, Wa. 98188 206-575-4407 Project: , �of Ipspection: Type�jJ e 'IV- A Lie_aloi Address: Suite #: 11/ S'c Me, /l Contact Person: Special Instructions: Phone No.: Approved per applicable codes. Corrections required prior to approval. COMMENTS: j%ec-h P74(1 / ' c-001p/e- i e Needs Shift Inspection: (.r5 Sprinklers: K05- 0SFire FireAlarm: 51-5 Hood & Duct: Monitor: Pre -Fire: Permits: Occupancy Type: Inspector f pyil scy Date: 41/WR Hrs.: / $100.00 REINSPECTION FEE REQUIRED. You will receive an invoice from the City of Tukwila Finance Department. Call to schedule a reinspection. Billing Address Attn: Company Name: Address: City: State: Zip: Word/Inspection Record Form.Doc 6/11/10 T.F.D. Form F.P. 113 July 2, 2013 John Douglas 6331 18th Ave. SW Seattle, WA. 98106 206-767-2908 RE: Aveda @ Southcenter — Scope of Work The following describes the mechanical, electrical and plumbing scope of work the new Aveda store in Southcenter Mall. Electrical The electrical scope of work shall include all work associated with a complete remodel. New wall, floor and ceiling mounted receptacles shall be installed. New connections shall be provided for mechanical and plumbing equipment. A new panelboard shall be provided and shall extend from existing landlord electrical gear. Work in the landlord's electrical room shall only consist of new overcurrent protection and new meter as required by the utility company. All new lighting and associated controls shall be installed per local energy code requirements. Fire alarm devices shall be provided per local jurisdiction and mall requirements. cal scope of work shall include all work associated with a complete remodel. All existing HVAC units and associated ductwork, piping, controls and accessories to be removed and replaced with new units (air -handling unit, roof —mounted condensing unit and restroom exhaust fan). All new ductwork, dampers, and air distribution devices shall be laid out as well as associated (programmable) thermostats and controls. New refrigerant piping to be installed for condensing unit and routed to interior air -handling unit. All accessories associated with fire alarm controls shall be provided per local jurisdiction and mall requirements Plumbing The plumbing scope of work shall include all work associated with a complete remodel. Cold water, sanitary waste and vent piping shall be extended to the sales floor for the installation of a new sink. A new instantaneous water heater will be provided for the new sales sink. Waste and vent piping in the restroom shall be extended for the installation of a new floor drain. Other plumbing fixtures (restroom lavatory, associated water heater and water closet) are existing to remain. A cold water line with a water box will be provided at the new water dispenser. A new vent through the roof will be provided for the waste and vent system. Sprinkler heads shall be provided and/or relocated to connect to existing system. Sprinkler contractor shall rebalance system per head layout RECEIVED CITY OF TUKWILA, JUL 0 2 20I PERMff CENTER kansas city, mo o www.Iarsonbinkley.com 0 816 997 9601 If you have any questions regarding the above scope, please don't hesitate to contact this office. Respectfully submitted, Adrian Franks Project Manager kansas city, mo • www.larsonbinkley.com • 816 997 9 PERMIT COORD COPY i PLAN REVIEW/ROUTING SLIP ACTIVITY NUMBER: M13-120 DATE: 07 - PROJECT NAME: AVEDA SITE ADDRESS: 211 SOUTHCENTER MALL X Original Plan Submittal Response to Incomplete Letter # Response to Correction Letter # Revision # After Permit Issuei DEPPARTMEENTS: ting'1Ln Public Works 4w, kwc1 Fire Prevention Structural Planning Division Permit Coordinator C et DETERMINATION OF COMPLETENESS: (Tues., Thurs.) Complete Comments: Incomplete DUE DATE: 07-09-13 Not Applicable n PermitCenter Use Only INCOMPLETE LETTER MAILED: LETTER OF COMPLETENESS MAILED: Departments determined incomplete: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: TUES/THURS ROUTING: Please Route Structural Review Required REVIEWER'S INITIALS: No further Review Required DATE: APPROVALS OR CORRECTIONS: Approved Approved with Conditions Notation: REVIEWER'S INITIALS: DUE DATE: 08-06-13 Not Approved (attach comments) n DATE: ' Permiftenter Use Only CORRECTION LETTER MAILED: Departments issued corrections: Bldg ❑ Fire ❑ Ping ❑ PW ❑ Staff Initials: Documents/routing slip.doc 2-28-02 Contractors or Tradespeople Pror Friendly Page General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name EVERGREEN REFRIGERATION LLC UBI No. 602512953 Phone 2067631744 Status Active Address 727 S Kenyon St License No. EVERGRL954R2 Suite/Apt. License Type Construction Contractor City Seattle Effective Date 1/6/2006 State WA Expiration Date 1/6/2014 Zip 98108 Suspend Date County King Specialty 1 General Business Type Limited Liability Company Specialty 2 Unused Parent Company ther Associated Licenses License Name Type Specialty 1 Specialty 2 Effective Date Expiration Date Status EVERGHH910J0 EVERGREEN HOME HEATING & ENGY Construction Contractor General Unused 4/20/2009 4/20/2015 Active EVERGI'201D7 EVERGREEN REFRIGERATION INC Construction Contractor General Unused 3/27/1980 7/31/2006 Re Licensed Business Owner Information Name Role Effective Date Expiration Date EVERGREEN REFRIGERATION LLC Partner/Member 12/22/2005 Bond Amount PATTON, DAVID Partner/Member 01/06/2006 WA15097 PATTON, RODGER Partner/Member 01/06/2006 PATTON, MATTHEW Partner/Member 01/06/2006 TRAVELERS CAS & SURETY CO Bond Information Page 1 of 1 Bond Bond Company Name Bond Account Number Effective Date Expiration Date Cancel Date Impaired Date Bond Amount Received Date 2 Merchants Bonding Co (Mutual) WA15097 01/01/2012 Until Cancelled $12,000.00 12/15/2011 1 TRAVELERS CAS & SURETY CO 104667361 01/01/2006 Until Cancelled $12,000.00 01/03/2006 Assignment of Savings Information No records found for the previous 6 year period Insurance Information Insurance Company Name Policy Number Effective Date Expiration Date Cancel Date Impaired Date Amount Received Date 3 AMERICAN FIRE AND CASUALTY COM BAW54192293 07/31/2010 07/31/2014 $1,000,000.00 07/30/2013 2 Continental Western Ins Co CWP2640663 07/31/2006 07/31/2010 $1,000,000.0003/23/2009 Summons/Complaint Information No unsatisfied complaints on file within prior 6 year period Warrant Information No unsatisfied warrants on file within prior 6 year period Infractions/Citations Information No records found for the previous 6 year period httnc•//fnrtrpcc wa anv/lni/hhin/Print.asnx 08/13/2013 MALL Ci, RR,DOR NOTE: DETERMINE ACTUAL ROOF TOP LOCATION OF OLD/NEW / CONDENSING UNIT. FIELD VERIFY AND COORDINATE / ACCORDINGLY (WITH LANDLORD) PRIOR TO BID. :ACM.. TENANT ART OF SHAVING STOGK,,'',O i Ii; { it TOILET ROM .l 250 SALES ::a..ILIN J, NOTE: RETURN AIR TO ABOVE THE CEILING IS PROVIDED THROUGH A LINEAR SLOTTED OPENING IN THE ARCHITECTURAL CEILING SOFFIT BY DESIGN. COORDINATE/CONFIRM WITH ARCHITECTURAL DRAWINGS. wo wuuuuuw uw• . w��umuuvc N Air System Information Air System Name Overall Store Number of zones 1 Equipment Class SPLT AHU Floor Area 800.0 ft' Air System Type SZCAV Location Seattle IAP, Washington Sizing Calculation Information Zone and Space Sizing Method: Zone CFM Sum of space airflow rates Calculation Months Jan to Dec Space CFM Individual peak space loads Sizing Data User -Modified Central Cooling Coil Sizing Data Total coil load 2.5 Tons Load occurs at . . . . Jun 1500 Total coil load 30.4 MBH OA DB / WB 84.0165.0 °F Sensible coil Toad 26.4 MBH Entering DB / WB 76.3163.2 °F Coil CFM at Jun 1500 1200 CFM Leaving DB / WB 55.6/54.4 °F Max block CFM 1200 CFM Coil ADP 53.3 °F Sum of peak zone CFM 1200 CFM - Bypass Factor 0.100 Sensible heat ratio - 0.869 Resulting RH 53 % ft'/Ton 315.9 Design supply temp. 57.0 °F BTU/(hr-ft') - 38.0 Zone T -stat Check 0 of 1 OK Water flow @ 10.0 °F rise N/A Max zone temperature deviation 0.8 °F Central Heating Coil Sizing Data Max coil load 13.1 MBH Load occurs at Des Htg Coil CFM at Des Htg 1200 CFM BTU/(hr-fl') 16.3 Max coil CFM 1200 CFM Ent. DB / Lvg DB 57.9 / 68.2 °F Water flow © 30.0 °F drop N/A Supply Fan Sizing Data Actual max CFM 1200 CFM Fan motor BHP 0.70 BHP Standard CFM 1131 CFM Fan motor kW 0.52 kW Actual max CFM/ft' 1.50 CFM/ft' Fan static 2.00 in wg Outdoor Ventilation Air Data Design airno;v CFM °5n r_rnn CFM/person 15.63 CFM/person CFM/ft' 0.31 CFM/ft' PLAN 3/8"O1MECHANICAL PLAN -1' -0" CONDENSING UNIT SCHEDULE DESIGN COOLING DESIGN HEATING B COOLING DATA AT Jun 1500 COOLING OA DB / WB 84.0°F/65.0°F HEATING DATA AT DES HTG HEATING OA DBI WB 23.0°F/19.2°F ZONE LOADS Details Sensible (BTU/hr) Latent (BTU/hr) Details Sensible (BTU/hr) Latent (BTU/hr) Window & Skylight Solar Loads 0 ft' 0 - 0 ft' - NO. OF FANS Wall Transmission 0 ft' 0 - 0 ft' 0 - Roof Transmission B00 ft' 3718 - 500 ft' 2484 - Window Transmission 0 ft' 0 - 0 ft' 0 - Skylight Transmission 0 ft' 0 - 0 ft' 0 - Door Loads 0 ft' 0 - Oft' 0 NEW Floor Transmission 800 ft' 0 - 800 ft' 0 - Partitions 0 ft' 0 - 0 ft' 0 - Ceiling 0 ft' 0 - 0 ft' 0 - Overhead Lighting 2000 W 5845 - 0 0 - Task Lighting 1200 W 3507 - 0 0 - Electric Equipment 800 W 2555 - 0 0 - People 16 3471 4320 0 0 0 Infiltration - 0 0 - 0 0 Miscellaneous - 0 0 - 0 0 Safety Factor 10% / 10% 1910 432 25% 621 0 » Total Zone Loads - 21006 ... 4752 . 3105 0 Zone Conditioning - 22044 j 4752 . 3112 0 Plenum Wall Load 0% 0 - 0 0 Plenum Roof Load 0% 0 - 0 0 - Plenum Lighting Load 0% 0 - 0 0 - Retum Fan Load 1200 CFM 0 - 1200 CFM 0 - Ventilation Load 250 CFM 2580 -770 250 CFM 11720 0 Supply Fan Load 1200 CFM 1779 - 1200 CFM -1779 - Space Fan Coil Fans - 0 - - 0 - DuctHeatGain/Loss 0% 0 - 0% 0 - » Total System Loads - 26403 3982 - 13052 0 Central Cooling Coil , - 26403 3983 - 0 0 Central Heating Coil - 0 - - 13052 - » Total Conditioning - 26403 ' 3983 - 13052 0 Key: Positive values are clg loads Negative values are htg loads Positive values are htg loads Negative values are clg loads PLAN 3/8"O1MECHANICAL PLAN -1' -0" CONDENSING UNIT SCHEDULE MARK (CU-#) 1 B MANUFACTURER CARRIER MANUFACTURER MODEL 24ANA1-36 TITUS AMBIENT OA TEMP (°F DB) 95 300RL TOTAL CAPACITY (BTU/HR) 36,600 PHYSICAL DATA 0.5 RETURN GRILLE NO. OF FANS 1 NECK SIZE (L"XW") NO. OF COMP. 1 SEE PLAN ELECTRICAL 36,600 24"X8" VOLTS/0/HZ 208/1/60 MCA (AMPS) 23.1 LAY -IN MOCP (AMPS) 30 FINISH APPROX. WEIGHT (LBS) 350 (EXIST UNIT +/- 350) ACCESSORIES ALL <30 NOTES NEW UNIT BUILDING PERMIT NO. VOLTS/0/HZ ACCESSORIES:PROVIDE 1) LIQUID LINE SIGHT GLASS, MOISTURE INDICATOR AND FILTER DRYER. 2) PROVIDE LOW AMBIENT KIT TO OPERATE AT 0 DEGREES F. 3) PROVIDE ACCESSORY HEAD PRESSURE CONTROL, ANTI -SHORT CYCLE CONTROL AND TIME DELAY ON COMPRESSOR RESTART. AIR HANDLING UNIT SCHEDULE MARK (AHU-#) 1 B MANUFACTURER CARRIER MANUFACTURER MODEL FE4ANB-003 TITUS AIR FLOW (CFM) 1200 300RL OA FLOW (CFM) 250 EXT. SP. (IN W.C.) 0.5 RETURN GRILLE DX COOLING COIL 80 NECK SIZE (L"XW") EAT (°FDB/WB) 80 SEE PLAN TOTAL (BTU/HR) 36,600 24"X8" SENSIBLE (BTU/HR) 25,800 ELECTRIC HEAT r . LAY -IN INPUT (WATTS) 5000 FINISH OUTPUT (BTU/HR) 17,000 PER ARCH STAGES 1 <30 ELECTRICAL 25 BUILDING PERMIT NO. VOLTS/0/HZ 208/1/60 MOTOR HP 1/2 NOTES MCA (AMPS) 28.4 NEW MOCP (AMPS) 30 APPROX. WEIGHT (LBS) 250 (EXIST UNIT +/- 200) ACCESSORIES ALL NOTES NEW UNIT ,,p.e.. ,. 3k5x-w..r maw...„a+ +,. .,F: su..- ACCESSORIES: 1) ECM MOTOR. 2) SINGLE POINT POWER CONNECTION. 3) FACTORY DISCONNECT SWITCH. 4) HEAT LOCKOUT FAN PROVING SWITCH. TENANT Aria REVISIONS No changes shall be made to the scope of work without prior approval of Tukwila Building Division. VOTE: Revisions will require a new plan submittal and may include additional plan review fees. DEMOLITION NOTES REMOVE ALL EXISTING MECHANICAL EQUIPMENT, DUCTWORK, HANGERS, SUPPORTS, PIPING, AND ACCESSORIES ONLY SERVING THIS SPACE AND NOT INDICATED TO REMAIN. CAP UNUSED ROOF CURBS WITH 18 GAUGE GALVANIZED SHEET METAL CAP. INSULATE CURB CAPS WITH 1' THICK 3 PCF DENSITY DUCT LINER, AND SEAL WATER TIGHT. FIELD VERIFY EXISTING CONDITIONS PRIOR TO BID. EXHAUST AND VENTILATION FAN SCHEDULE MARK (EF #) 1 B MANUFACTURER BROAN MANUFACTURER MODEL L100 TITUS TYPE CEILING 300RL DRIVE TYPE DIRECT PERFORMANCE SUPPLY REGISTER RETURN GRILLE AIR. FLOW (CFM) 80 NECK SIZE (L"XW") EXT. STATIC (IN W.C.) 0.375 SEE PLAN FAN SPEED (RPM) 640 24"X8" ELECTRICAL 24X24 VOLTS/0/HZ 120/1/60 LAY -IN FAN MOTOR HP DATE FINISH FAN MOTOR WATTS 87 PER ARCH ACCESSORIES ALL <30 APPROX. WEIGHT (LBS) 25 BUILDING PERMIT NO. SERVES RESTROOM NOTES SWITCH W/LIGHTS NOTES NEW ACCESSORIES: 1) BACKDRAFT DAMPER. 2) DISCONNECT PLUG. SEPARATE: PERMIT i EOUIRED FOR: ❑ Mechanical Electrical [rilumbkg Cel as Piping CEsy of Tukwila BtU LOING DIVISION, GRILLE, REGISTER, AND DIFFUSER SCHEDULE MARK A B C MANUFACTURER TITUS TITUS TITUS MODEL 300RL 350RL TMS TYPE SUPPLY REGISTER RETURN GRILLE SUPPLY DIFFUSER NECK SIZE (L"XW") - 22"X6" 22"X22" SEE PLAN FACE SIZE (L"XW") 24"X8" 24"X24" 24X24 FRAME TYPE SURFACE LAY -IN LAY -IN DATE FINISH PER ARCH PER ARCH PER ARCH ORIG. DATE: 00.00.00 NOISE CRITERIA LEVEL <30 <30 <30 BUILDING PERMIT NO. ACCESSORIES ALL NOTES NEW NEW NEW �a�G rrr_i..a�i ACCESSORIES: 1) SQUARE TO ROUND DUCT ADAPTER. 2) FACE ADJUSTABLE VOLUME DAMPER. GENERAL NOTES A. CONTRACTORS AND SUB -CONTRACTORS SHALL CAREFULLY REVIEW THE CONSTRUCTION DOCUMENTS. INFORMATION REGARDING THE COMPLETE WORK::; IS DISPERSED THROUGHOUT THE DOCUMENT SET AND CANNOT BE ACCURATELY DETERMINED WITHOUT REFERENCE TO THE COMPLETE DOCUMENT SET. B. COORDINATE WITH THE WORK OF OTHER SECTIONS, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE OWNER, AND WITH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE. PROVIDE DUCT RISES AND DROPS AS REQUIRED FOR FIELD INSTALLATION AND TRADE COORDINATION. NOTIFY ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING WORK. C DRAWINGS FOR HVAC WORK ARE DIAGRAMMATIC, SHOWING THE GENERAL LOCATION, TYPE, LAYOUT, AND EQUIPMENT REQUIRED. THE DRAWINGS SHALLNOT BE SCALED FOR EXACT MEASUREMENT. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS. REFER TO MANUFACTURER'S STANDARD INSTALLATION DRAWINGS FOR EQUIPMENT CONNECTIONS AND INSTALLATION REQUIREMENTS. PROVIDE DUCTWORK, CONNECTIONS, ACCESSORIES, OFFSETS, AND MATERIALS NECESSARY FOR A COMPLETE SYSTEM. D. ALL WORK SHALL COMPLY WITH STATE AND LOCAL CODE REQUIREMENTS AS APPROVED AND AMENDED BY THE GOVERNING CITY. PURCHASE ALL PERMITS ASSOCIATED WITH THE WORK. OBTAIN ALL INSPECTIONS REQUIRED BY CODE. E. PROVIDE TURNING VANES IN ALL SQUARE (90 DEGREE) ELBOWS. F. CONTRACT WITH LANDLORD'S APPROVED ROOFING CONTRACTOR TO FLASH AND SEAL ALL OLD AND NEW ROOF PENETRATIONS AND TO PERFORM ALL OTHER ROOF RELATED WORK. G. THERE SHALL BE NO COMBUSTIBLE MATERIALS INSTALLED WITHIN THE RETURN AIR CEILING PLENUM. MECHANICAL PLAN NOTES ❑1 PROVIDE NEW 7 -DAY PROGRAMMABLE THERMOSTAT (T) WITH AUTO -CHANGEOVER AND NEW REMOTE SENSOR (S) COMPATIBLE WITH AIR HANDLING UNIT AND ANY LANDLORD CONTROLS REQUIREMENTS. MOUNT 48" AFF. COORDINATE SIZE AND STYLE OF REMOTE SENSOR WITH ARCHITECT. COLOR SHALL BE BLACK OR STAINLESS STEEL. SEE ALSO AIR HANDLING UNIT SCHEDULE THIS SHEET. ❑2 NEW SIDEWALL SUPPLY REGISTER LOCATED IN VERTICAL FACE OF DROPPED CEILING AREA. SEE ARCHITECTURAL DRAWINGS. BALANCE SUPPLY REGISTERS TO CFMs INDICATED. ❑3 UNDERCUT RESTROOM DOOR ONE INCH FOR TRANSFER AIR. 4 REMOVE EXISTING AND PROVIDE NEW ROOF MOUNTED CONDENSING UNIT AND MOUNTING RAILS. COORDINATE EXACT MOUNTING LOCATION WITH LANDLORD. SIZE, PROVIDE, CONNECT AND INSULATE REFRIGERANT PIPING TO ASSOCIATED AHU PER MANUFACTURER'S RECOMMENDATIONS. CONTRACT WITH LL's ROOFING CONTRACTOR TO PERFORM ALL ROOFING WORK. ❑5 REMOVE EXISTING AND PROVIDE NEW AIR HANDLING UNIT. INSTALL UNIT LEVEL FOR PROPER CONDENSATE DRAINAGE. SUPPORT UNIT FROM STRUCTURE ABOVE WITH EXISTING SUSPENSION COMPONENTS AND SEISMIC BRACING. PROVIDE ANY NEW ITEMS REQUIRED. © REFRIGERANT PIPE(S) SIZES SHALL BE DETERMINED BY THE COMPRESSORIZED EQUIPMENT MANUFACTURER OR THEIR REPRESENTATIVE, WHO SHALL ALSO DETERMINE THE NEED FOR DOUBLE SUCTION PIPE RISERS, ACCUMULATORS AND OTHER APPURTENANCES REQUIRED FOR PROPER LONG TERM OPERATION OF THE EQUIPMENT. REFRIGERANT PIPE(S) SIZING AND ROUTING SHALL MEET ALL SYSTEM OPERATING CONDITIONS. THE CONTRACTOR SHALL PROVIDE TO THE OWNER AND ENGINEER LETTERS AND DRAWINGS THAT ADEQUATELY DEPICT THE REFRIGERANT PIPING AND COMPONENTS, AND INDICATE THE RECOMMENDATIONS PROVIDED TO THEM BY THE MANUFACTURER OR THEIR - REPRESENTATIVE. Q PROVIDE RETURN AIR BOOT WITH ACOUSTICAL DUCT LINER. LINER SHALL BE 1" THICK 3 PCF DENSITY, LONG TEXTILE TYPE FIBER, WITH SURFACE CLEANABLE PER NAIMA DUCT CLEANING GUIDELINES. INSTALL LINER IN ACCORDANCE WITH SMACNA DUCT CONSTRUCTION STANDARDS. LAMINATE LINER TO INTERNAL SURFACES OF DUCT IN ACCORDANCE WITH LINER MANUFACTURER'S INSTRUCTIONS, AND FASTEN WITH MECHANICAL FASTENERS. PROVIDE MANUAL DAMPER FOR BALANCING OUTSIDE AIR. ® PROVIDE CEILING MOUNTED EXHAUST FAN. TRANSITION FROM FAN DISCHARGE TO DUCT SIZE SHOWN AND EXTEND/CONNECT TO EXISTING DUCT EXITING SPACE THROUGH ROOF. FIELD VERIFY LOCATION/DISTANCE AND CONNECTION REQUIREMENTS. REPAIR AND REATTACH EXISTING DUCT. ❑9 TAP RETURN AIR BOOT WITH OUTSIDE AIR (0/A) DUCT. EXTEND 0/A DUCT TO LANDLORD'S PRIMARY OUTSIDE AIR DUCT AND CONNECT PER LL REQUIREMENTS. PROVIDE (1) MANUAL DAMPER AND (1) ELECTRICALLY OPERATED DAMPER (EOD) AS INDICATED. SET MANUAL DAMPER TO PROVIDE OUTSIDE AIR CFM SCHEDULED. EOD SHALL FULLY OPEN DURING OCCUPIED HOURS AND FULLY CLOSE DURING UNOCCUPIED PERIODS. SEE ALSO LANDLORD DUCTING NOTE, THIS SHEET. 10 DUCT MOUNTED SMOKE DETECTOR FURNISHED BY FIRE ALARM CONTRACTOR AND INSTALLED IN DUCT BY MECHANICAL CONTRACTOR. INTERLOCK WIRING BETWEEN FIRE ALARM SYSTEM RELAY AND ROOFTOP UNIT SHUTDOWN CONTACT SHALL BE PROVIDED BY MECHANICAL CONTRACTOR. ALL OTHER WIRING BY FIRE ALARM CONTRACTOR. UPON DETECTION OF SMOKE, ROOFTOP UNIT SHALL SHUT DOWN UPON SIGNAL FROM FIRE ALARM SYSTEM. FILE COPY' Permit No. M bb 121) Plan review approval is subject to errors and omens. r ,� "at of construction docurients does not authorize tir of any adopted code or ordinance. Receipt of approved Field Copy and conditions isacknowledged: By l Date, %/1)/() City Ofe BUILDING DIVISION REVIEWED FOR CODE COMPLIANCE APPROVED JUL 2 2 2013 Az-- WI-, City of Tukwila BUILDING DIVISION RECEIVED CITY OF TUKWILA JUL 022013 PERMIT CENTER zd 012013081 1 M10.dwg 06-18-13 19;26 Reggie.Everhart ENGINEER THIS SHEET IS PART OF THE CONSTRUCTION DOCUMENTS, OTHER SHEETS INCLUDING SPECIFICATIONS APPLY. THAT SHOWN HEREON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWING; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL ENGINEER HAS NOT SIGNED AND SEALED PER STATE REQUIREMENTS. LARSON BINKLEY Larson Binkley, Inc. 310 W 20th Street, Suite 200 Kansas City, MO 64108 Washington Certificate of Authorization Number C1266 T 816-997-9601 F 816-997-9602 larsonbinkley.com Copyright 2013 OWNER AV E DA THE ART AND SCIENCE OF PURE FLOWER AND PLANT ESSENCES 767 FIFTH AVENUE NEW YORK, NY10153 AVEDA Southcenter Mall 2800 Southcenter Space No. 636, Level 1 Tukwila, WA 98188 DRAWING TITLE MECHANICAL PLAN REVISIONS 06.28.13 ISSUE FOR LL REVIEW/PERMIT/BID NO. DATE REVISION DRAWN BY: RGE CHECKED BY: JMC ORIG. DATE: 00.00.00 REV. DATE: 00.00.00 JOB NO. PROJECT NO. #### SHEET NO. 1 . 0 BUILDING PERMIT NO. MECHANICAL SPECIFICATIONS PROVIDE EQUIPMENT INDICATED ON THE DRAWINGS, AND AS REQUIRED FOR A COMPLETE FUNCTIONING SYSTEM. DEFINITIONS: FURNISH MEANS TO SUPPLY AND DELIVER TO PROJECT SITE, READY FOR INSTALLATION. INSTALL MEANS TO PLACE IN POSITION AND MAKE CONNECTIONS FOR SERVICE OR USE. PROVIDE MEANS TO FURNISH AND INSTALL, COMPLETE AND READY FOR INTENDED USE. WARRANTY: PROVIDE LABOR AND MATERIALS TO REPAIR OR REPLACE DEFECTIVE PARTS AND MATERIALS AS REQUIRED FOR ONE YEAR AFTER SUBSTANTIAL COMPLETION OR OWNER ACCEPTANCE OF THE COMPLETED PROJECT. PROVIDE A SEPARATE LINE ITEM DEDUCT AMOUNT ON THE PROPOSAL FORM TO DELETE WARRANTY SERVICE, AT THE OWNER'S OPTION. COORDINATION: COORDINATE WITH THE WORK OF OTHER TRADES, EQUIPMENT FURNISHED BY OTHERS, REQUIREMENTS OF THE OWNER, AND WITH THE CONSTRAINTS OF THE EXISTING CONDITIONS OF THE PROJECT SITE. DUCT DIMENSIONS: UNLESS OTHERWISE NOTED, DUCT DIMENSIONS ON THE DRAWINGS ARE INSIDE CLEAR DIMENSIONS. SHEETMETAL DUCTWORK: DOWNSTREAM FROM AIR OUTLET OF UNITS, PROVIDE SHEETMETAL DUCTWORK FABRICATED AND INSTALLED IN ACCORDANCE WITH ASHRAE AND SMACNA STANDARDS FOR 1" W.G. PRESSURE CLASS, SEAL CLASS "A". SHEETMETAL SHALL BE GALVANIZED SHEET STEEL OF LOCK FORMING QUALITY, WITH G90 ZINC COATING. SHEET STEEL SHALL COMPLY WITH ASTM A653 STANDARD SPECIFICATION FOR STEEL SHEETMETAL, ZINC COATED (GALVANIZED) OR ZINC—IRON ALLOY—COATED (GALVANNEALED) BY THE HOT DIP PROCESS, AND A924 STANDARD SPECIFICATION FOR GENERAL REQUIREMENTS FOR SHEET, METALLIC—COATED BY THE HOT DIP PROCESS. ALL ANGLE IRON USED FOR SUPPORT SHALL BE GALVANIZED. CONNECTIONS TO WALLS OR FLOOR SHALL BE AIR TIGHT WITH ANGLE IRON AND CAULKING. SEAL ALL DUCT SEAMS, TRANSVERSE AND LONGITUDINAL, AIR TIGHT. PROVIDE TURNING VANES AT ALL 90° ELBOWS. ROUND SHEETMETAL DUCT: PROVIDE SPIRAL SEAM (ALL EXPOSED DUCT) OR SNAP LOCK (DUCT SIZES UP TO 10" AND NOT EXPOSED DUCT) GALVANIZED STEEL COMPLYING WITH SMACNA STANDARDS. SPIRAL SEAM DUCTWORK SHALL HAVE SMACNA SEAM TYPE RL -1. FLEXIBLE DUCT: PROVIDE FACTORY ASSEMBLED CLASS 1 AIR DUCT (UL 181) WITH 1" THICK 1 PCF FIBERGLASS INSULATION AND REINFORCED OUTER PROTECTIVE COVER/VAPOR BARRIER. FLEXIBLE DUCT SHALL MEET NFPA 90A WITH FLAME SPREAD UNDER 25, SMOKE DEVELOPED UNDER 50, AND SHALL BE RATED FOR MINIMUM 2" W.G. PRESSURE AND 0 TO 250T TEMPERATURE. PROVIDE SCREW—OPERATED METAL ADJUSTABLE CLAMPING DEVICES. USE TWIST—LOCK TAP COLLARS AT CONNECTIONS INTO SHEETMETAL DUCTWORK. MAXIMUM EXTENDED LENGTH OF FLEXIBLE DUCT SHALL NOT EXCEED 6 FEET. DUCT SEALANT: PROVIDE POLYMERIC RUBBER TYPE SEALANT FOR USE ON BOTH INTERIOR LOCATED DUCTWORK AND DUCTWORK EXPOSED TO OUTDOOR CONDITIONS. SEALER SHALL HAVE HIGH BONDING STRENGTH FOR SURE, FIRST TIME SEALING OF JOINTS IN LOW, MEDIUM, AND HIGH PRESSURE DUCT SYSTEMS. SEALER SHALL BE HIGH IN SOLID CONTENT. PROVIDE A TWO PART TAPE SEALING SYSTEM, CONSISTING OF WOVEN FIBER TAPE IMPREGNATED WITH A GYPSUM MINERAL COMPOUND, AND A MODIFIED ACRYLIC/SILICONE ACTIVATOR THAT REACTS EXOTHERMICALLY WITH THE TAPE. TWO PART TAPE SEALING SYSTEM MUST . BE RATED FOR BOTH INDOOR AND OUTDOOR APPLICATION. TAPE SHALL NOT CONTAIN ASBESTOS. DUCT INSULATION (ALL ROUND SUPPLY DUCT AND OUTSIDE AIR DUCT ABOVE CEILING): PROVIDE MINIMUM 1-1/2" THICK BLANKET TYPE FIBERGLASS INSULATION COMPLYING WITH ASTM C-553, TYPE II, WITH FACTORY APPLIED KRAFT BONDED TO ALUMINUM FOIL, REINFORCED WITH FIBERGLASS VAPOR BARRIER/JACKET. JACKET SHALL CONFORM TO ASTM C-1136, TYPE II. INSTALLED R VALUE SHALL BE 4.2 OR HIGHER WITH A 0.75 PCF DENSITY. INSTALLED R VALUE FOR EXTERIOR (ROOF) DUCTWORK SHALL BE 8.0 OR HIGHER. DUCT LINER (ALL RECTANGULAR RETURN DUCT AND RECTANGULAR SUPPLY DUCT): PROVIDE MINIMUM 1" THICK, 3 PCF DENSITY, NEOPRENE COATED, LONG TEXTILE FIBER TYPE DUCT LINER, WITH COATING ON THE AIR STREAM SIDE CONFORMING TO NFPA 90A. DUCT LINER ADHESIVE SHALL BE AS RECOMMENDED BY DUCT LINER MANUFACTURER, AND SHALL COMPLY WITH ASTM C-916. DUCT LINER FASTENERS SHALL COMPLY WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS", LATEST EDITION. THERMAL CONDUCTIVITY SHALL BE EQUAL TO OR LESS THAN 0.26 AT 75T. ROUND VOLUME DAMPERS: PROVIDE MINIMUM 20 GAUGE GALVANIZED STEEL FRAME AND BLADES, MINIMUM 3/8" SQUARE STEEL AXLE, MOLDED SYNTHETIC BEARINGS, WITH LOCKING POSITION REGULATOR. REGULATOR SHALL BE POSITIONED WITH SHEETMETAL BRACKET BEYOND DUCT COVERING. WHERE POSITIONING REGULATOR IS NOT ACCESSIBLE, PROVIDE COUPLING AND EXTENSION ROD WITH REGULATOR FOR CEILING OR WALL INSTALLATION, AS REQUIRED. RECTANGULAR VOLUME DAMPERS: PROVIDE MINIMUM 16 GAUGE GALVANIZED STEEL CHANNEL FRAME, 16 GAUGE GALVANIZED STEEL BLADES, MINIMUM W' HEXAGONAL AXLE, BOLDED SYNTHETIC BEARINGS, WITH 3/8" SQUARE PLATED STEEL CONTROL SHAFT. LINKAGES SHALL BE CONCEALED IN THE FRAME. OPERATING SHAFT SHALL EXTEND BEYOND FRAME AND DUCT TO A LOCKING QUADRANT WITH ADJUSTABLE LEVER. MAXIMUM BLADE WIDTH SHALL NOT EXCEED 6". DUCT TURNING VANES: PROVIDE FABRICATED TURNING VANES AND VANE RUNNERS, CONSTRUCTED IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARDS". PROVIDE TURNING VANES CONSTRUCTED OF CURVED BLADES, SUPPORTED WITH BARS PERPENDICULAR TO BLADES, AND SET INTO SIDE STRIPS SUITABLE FOR MOUNTING IN DUCTWORK. FOLLOW SMACNA GUIDELINES FOR SPACING SUPPORT, AND CONSTRUCTION. ALL BLADES SHALL BE DOUBLE THICKNESS AIRFOIL TYPE. FI EYIRI E TTI IC`T f11NMFrTriRS; PRf1VIIlr 11,I , I ARE1 rn Vi (1I INrr NEOPRENE COATED FIBERGLASS FABRIC DUCT CONNECTORS AT DUCT CONNECTIONS TO ALL VIBRATING EQUIPMENT. DUCT ACCESS DOORS: PROVIDE HINGED ACCESS DOORS IN DUCTWORK WHERE REQUIRED FOR ACCESS TO EQUIPMENT. PROVIDE INSULATED ACCESS DOORS FOR INSULATED DUCTWORK. CONSTRUCT OF SAME OR THICKER GAUGE SHEETMETAL AS DUCT IN WHICH IT IS INSTALLED. PROVIDE FLUSH FRAMES FOR UNINSULATED DUCTS, AND EXTENDED FRAMES FOR EXTERNALLY INSULATED DUCTS. PROVIDE CONTINUOUS HINGE ON ONE SIDE, WITH ONE HANDLE -TYPE LATCH FOR ACCESS DOORS 12" HIGH AND SMALLER, AND TWO HANDLE -TYPE LATCHES FOR LARGER ACCESS DOORS. TESTING AND BALANCING: TEST AND ADJUST ALL MECHANICAL SYSTEMS AND EQUIPMENT TO ASSURE PROPER BALANCE AND OPERATION. PERFORM TESTS IN ACCORDANCE WITH THE MOST CURRENT NEBB OR AABC, AND ASHRAE STANDARDS. ELIMINATE OBJECTIONABLE NOISE AND VIBRATION, AND ASSURE PROPER FUNCTION OF CONTROLS. BALANCING CONTRACTOR SHALL BE AN INDEPENDENT CERTIFIED TEST AND BALANCE CONTRACTOR, WITH NEBB OR MBC CERTIFICATION. SUBMIT COMPLETED AND CERTIFIED TEST AND BALANCE REPORT TO OWNER'S REPRESENTATIVE. BALANCE ALL SYSTEMS TO WITHIN 5% OF AIR FLOWS INDICATED ON THE DRAWINGS, AND REPORT ALL DISCREPANCIES TO HVAC INSTALLER FOR CORRECTION. MARK FINAL BALANCE POSITIONS ON DAMPERS WITH PERMANENT MARKER. REFRIGERANT PIPING: TYPE ACR HARD DRAWN COPPER TUBING MEETING THE REQUIREMENTS OF ASTM B280, WITH WROUGHT COPPER FITTINGS MEETING REQUIREMENTS OF ANSI B16.22, WITH BRAZED JOINTS MEETING REQUIREMENTS OF AWS A 5.8, USING BAG -1 (SILVER) FILLER MATERIAL. INSULATE SUCTION LINE PIPING WITH 1" THICK ARMAFLEX TYPE AP. MECHANICAL SYMBOLS LEGEND DOUBLE LINE DUCT SYMBOLS: yl SHEET METAL DUCTWORK & SIZE DUCTWORK TRANSITION --! ROUND SPIN—IN WITH DAMPER EQUIPMENT: FLEXIBLE DUCTWORK ABBREVIATIONS: CICEILING MOUNTED EXHAUST FAN FAN COIL / AIR HANDLING UNIT CONDENSING UNIT THERMOSTAT — ELECTRIC TEMPERATURE SENSOR i' ^" 0 CS AFF ABOVE FINISHED FLOOR CFM CUBIC FEET PER MINUTE ESP EXTERNAL STATIC PRESSURE LAT LEAVING AIR TEMPERATURE NC NOISE CRITERIA OA OUTSIDE AIR RA RETURN AIR SA SUPPLY AIR TYP TYPICAL GRILLES DIFFUSERS: GENERAL SQUARE SUPPLY DIFFUSER LINEAR SLOT DIFFUSER/RETURN SIDEWALL MOUNTED SUPPLY/RETURN RETURN GRILLE Fri REFERENCES/NOTATIONS: 06.28.13 ISSUE FOR LL REVIEW/PERMIT/BID NO. DATE MECHANICAL EQUIPMENT DESIGNATION DIFFUSER DESIGNATION AND CFM NOTE DESIGNATION REVISION DESIGNATION Mk DRAWN BY: RGE mr ORIG. DATE: 00.00.00 REV. DATE: 00.00.00 CFM f A\1 NOT ALL SYMBOLS OR ABBREVIATIONS ARE NECESSARILY USED LANDLORD REQUIREMENTS TENANT'S HVAC SYSTEM AND RELATED ROOF TOP EQUIPMENT SHALL BE COMPATIBLE WITH ANY LANDLORD LIFE SAFETY / SMOKE EVAC SYSTEM. VERIFY REQUIREMENTS WITH CENTER MANAGEMENT. PROVIDE TENANT'S NAME AND SPACE NUMBER ON ALL ROOF TOP EQUIPMENT PER LANDLORD REQUIREMENTS. VERIFY WITH CENTER MANAGEMENT. PROVIDE ROOF PROTECTION PADS AROUND ALL ROOF TOP EQUIPMENT AND UNDER ALL PIPING. VERIFY ROUTING OF CONDENSATE LINES WITH CENTER MANAGEM ENT. VERIFY LOCATION AND INSTALLATION OF ANY NEW ROOF TOP EQUIPMENT WITH CENTER MANAGEMENT. ANY ALTERATIONS TO LANDLORD'S EXISTING STRUCTURE WILL REQUIRE STRUCTURAL ANALYSIS PERFORMED BY A LICENSED ENGINEER AT TENANT'S EXPENSE. ANY ATTACHMENTS TO LANDLORD'S STRUCTURE SHALL BE FROM TOP CHORD OF JOIST ONLY. NO ATTACHMENT TO THE ROOF DECK IS PERMITTED. SUPPORTS/BRACE ALL MECHANICAL EQUIPMENT AND ACCESSORIES SO AS TO BE IN COMPLIANCE WITH THE LATEST SEISMIC REQUIREMENTS FOR THE AREA. MAINTAIN COMPLETE AND ACCURATE 'AS—BUILT' DRAWINGS FOR SUBMITTAL TO LANDLORD UPON JOB COMPLETION. COVER RETURN AIR OPENINGS BEFORE AND DURING CONSTRUCTION. VERIFY ALL DEMOLITION AND NEW WORK REQUIRED BY THE LANDLORD THAT IS NOT SHOWN ON THE PLANS WITH THE MALL OPERATIONS MANAGER PRIOR TO BID. VERIFY ANY WORK REQUIRED TO PROTECT EXISTING FIRE ALARM / LIFE SAFETY SYSTEMS DURING DEMOLITION AND NEW CONSTRUCTION WITH THE MALL OPERATIONS MANAGER PRIOR TO BID. PROVIDE ACCESS TO ANY LANDLORD EQUIPMENT ABOVE GYP BOARD CEILINGS AND OTHER INACCESSIBLE AREAS AS REQUIRED. COORDINATE REQUIRED LOCATIONS WITH ARCHITECT AND MALL OPERATIONS MANAGER PRIOR TO BID. THE LANDLORD'S MALL OPERATIONS MANAGER SHALL HAVE THE AUTHORITY TO MAKE ANY ON—SITE DECISIONS AND FIELD CHANGES IN ACCORDANCE WITH THE LANDLORD'S DESIGN CRITERIA; AND ANY SPECIFIC MALL OPERATIONS NEEDS/REQUIREMENTS NOT NOTED ON PLANS. CONTRACTOR SHALL OBTAIN A COPY OF THE LANDLORD'S TENANT DESIGN CRITERIA/REQUIREMENTS FROM THE MALL OPERATIONS MANAGER AND BECOME FAMILIAR WITH THE CONTENTS PRIOR TO BIDDING THE JOB. WHEN LANDLORD'S REQUIREMENTS CONFLICT WITH CODES OR ORDINANCES, THE STRICTEST INTERPRETATION SHALL APPLY. FAN SECTION SUPPORT UNIT FROM STRUCTURE ABOVE WITH EXISTING SUSPENSION COMPONENTS AND SEISMIC BRACING. PROVIDE ANY NEW ITEMS REQUIRED. FLEXIBLE DUCT CONNECTOR CONDENSATE OVERFLOW DRAIN 02 INSULATE SUCTION LINE WITH 1" FLEXIBLE UNICELLULAR INSULATION. J L FLAT FILTER SECTION FLEXIBLE DUCT CONNECTOR 'Th.-- OUTSIDE AIR DUCT WITH BALANCING DAMPER LINED RETURN AIR DUCT. REFER TO PLAN FOR SIZE. - 22 GAUGE GALVANIZED AUXILIARY DRAIN PAN CONDENSATE DRAIN. REFER TO PLAN FOR SIZE AND ROUTE. AIR HANDLING UNIT INSTALLATION DETAIL NOT TO SCALE WRAPPED INSULATION COVERING RIGID ROUND DUCT RIGID ROUND SHEET METAL DUCT BALANCING DAMPER INSULATED SUPPLY DUCT FLEXIBLE DUCT CONNECTION BALANCING HANDLE. LOCK INTO POSITION AND MARK PERMANENTLY. NOTES: 1) INSULATED FLEXIBLE DUCT PROTECTION SADDLE DIFFUSER STARTER COLLAR (MINIMUM 4"). X 20 GAUGE GALVANIZED SUPPORT STRAP SQUARE TO ROUND ADAPTOR (IF REQUIRED) PROVIDE AT FLEXIBLE DUCT CONNECTION METAL OR "PANDUIT" DRAWBAND ON THE INTERIOR FLEXIBLE DUCT HELIX. SECURE THE INSULATION OVER THE DRAW BAND WITH AN ADDITIONAL DRAWBAND. 2) PROVIDE BEADING ON ROUND METAL DUCT 12" OR LARGER IN DIAMETER. 3) PROVIDE MINIMUM 4" COLLARS FOR ATTACHMENT OF THE FLEXIBLE DUCT TO ROUND DUCT, DAMPERS AND DIFFUSERS. 4) BAND RIGID ROUND DUCT INSULATION TO DUCT AND PROVIDE TAPE FOR INSULATION OVERLAP. 04 DIFFUSER CONNECTION DETAIL- FLEX DUCT NOT TO SCALE RISE H PLAN DUCT OFFSET PLAN TRANSITION W/ EQUIPMENT PLAN VIEW FOB) V1 A° FOB PLAN VIEW BRANCH DUCT NOTES: 1) ANGLE A = 2) ANGLE A ELEVATION ELEVATION FOT I FOT PLAN VIEW CEILING SUPPLY DIFFUSER WITH LAY—IN FRAME (SURFACE MOUNT FRAME SIMILAR) ELEVATION 30° WHEN AIR FLOWS IN DIRECTION OF ARROW (SUPPLY AIR). 20° WHEN AIR FLOWS IN OPPOSITE DIRECTION OF ARROW (RETURN OR EXHAUST). 0 5 LOWSCALE VELOCITY DUCT FITTINGS DETAIL NOT TO EXISTING PENETRATION MAY BE REUSED IF PERMISSION. FIELD 1ERIFT'. REINFORCED INSULATED SHEET METAL. CAULK ALL JOINTS, AND POSITION TO SHED WATER COUNTERFLASHING WITH FASTENERS © 24" 0.C. BASE FLASHING W/ FASTENERS © 8" 0.C. ADEQUATE AND WITH LANDLORD'S SLOPE TOP (D 1/4" PER FOOT DEKTITE NEOPRENE COLLAR. SECURE IN PLACE WITH SCREWS TO HOOD AND METAL BANDS AROUND THE PIPES. SEAL WATER TIGHT. 30' ANGLE WOOD BLOCKING CANT STRIP ROOF STRUCTURE) 01 PIPE ROOF PENETRATION NOT TO SCALE ROOF INSULATION EXISTING MOUNTING RAILS MAY BE REUSED IF ADEQUATE AND WITH LANDLORD'S PERMISSION. FIELD VERIFY. WOOD NAILER COUNTERFLASHING r EQUIPMENT SUPPORT RAIL (PATE ES -5 OR APPROVED EQUAL) ROOF INSULATION ROOF STRUCTURE BASE PLATE 0 02 EQUIPMENT SUPPORT RAIL DETAIL NOT TO SCALE VIEWED E COMPLIANCE APPROVED JUL 2 2 2013 City of Tukwila W.OING DIVISION 1 RECEIVED CITY OF TUKWILA JUL 0 2 2013 PERMIT CENTER ENGINEER THIS SHEEP IS PART OF THE CONSTRUCTION DOCUMENTS, OTHER SHEETS INCLUDING SPECIFICATIONS APPLY. THAT SHOWN HEREON IS SCHEMATIC IN NATURE AND NOT TO BE USED AS A SHOP DRAWING; THEREFORE, INCLUDE ALL MODIFICATIONS REQUIRED TO CONFORM TO SITE CONDITIONS AND THE EQUIPMENT AND MATERIAL USED. VERIFY LOCATIONS AND DIMENSIONS OF ALL ARCHITECTURAL AND STRUCTURAL ELEMENTS AS SHOWN ON THEIR RESPECTIVE DOCUMENTS, THESE ELEMENTS ARE SHOWN FOR REFERENCE AND SHALL BE VERIFIED PRIOR TO CONSTRUCTION AND THE ENGINEER ASSUMES NO LIABILITY FOR THE ACCURACY OF THESE ELEMENTS. NO DESIGN RESPONSIBILITY IS ASSUMED FOR ANY PORTION OF THE WORK THAT THE PROFESSIONAL ENGINEER HAS NOT SIGNED AND SEALED PER STATE REQUIREMENTS. LARSON BINKLEY Larson Binkley, Inc. 310 W 20th Street, Suite 200 Kansas City. MO 64108 Washington Certificate of Authorization Number C1266 T 816-997-9601 F 816-997-9602 larsonbinkley.com Copyright 2013 OWNER AVEDA THE ART AND SCIENCE OF PURE FLOWER•AND PLANT ESSENCES 767 FIFTH AVENUE NEW YORK, NY 10153 AVEDA Southcenter Mall 2800 Southcenter Space No. 636, Level 1 Tukwila, WA 98188 DRAWING TITLE MECHANICAL NOTES AND DETAILS REVISIONS 06.28.13 ISSUE FOR LL REVIEW/PERMIT/BID NO. DATE REVISION DRAWN BY: RGE CHECKED BY: JMC ORIG. DATE: 00.00.00 REV. DATE: 00.00.00 JOB NO. PROJECT NO. #### SHEET NO. M2•0 BUILDING PERMIT NO. 0120130811 M20.dwg 06-26-13 13:00 Reggie.Everhart